Click to a PDF of our current catalog

Transcription

Click to a PDF of our current catalog
Anesthesia Systems Buyer’s Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Glossary of Anesthesia and Service Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
VetEquip Anesthesia Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Lab Animal Inhalation Anesthesia 101 DVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Complete Anesthesia Systems
COMPAC5 Lab Animal Anesthesia System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Mobile COMPAC5 Lab Animal Anesthesia System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
COMPAC5 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Rodent Circuit Controller (RC2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Mobile Rodent Circuit Controller (RC2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
IMPAC6 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Basic Lab Animal Anesthesia Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Anesthesia Machines and Machine Components
Anesthesia Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Vaporizers, Fill Devices, Inlets and Outlets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Carrier Gas Information and Supplies
Cylinders, Descriptions, Regulators, and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Quick Disconnects, Wall Plate Connections, High Pressure Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Breathing Circuits, Nosecones, Facemasks and Induction Chambers
Table of Contents
Starting Out
Non-rebreathing Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Nosecones, Finger Cot Kit, Facemasks, Diaphragms, Stereotaxic Nosecones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Induction Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Rebreathing Circuits, Reservoir Bags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Rebreathing Machine Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Euthanasia Supplies
3 Stage Solution Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
CO2 Flowmeters, Regulators and Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Universal Lids, Rat and Mouse Housing Cage Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Waste Gas Information and Supplies
Waste Gas Information, NIOSH & OSHA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Waste Gas Monitoring and Badges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Waste Control Valve, VaporGuard Activated Carbon Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
DSx Vented, Warmed Surgery Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Self Contained Evacuation Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Vented Induction Chambers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Downdraft Anesthesia Work Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Ventilators
Ventilators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Interfacing Ventilators with Anesthesia Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Rodent Intubation Aids
Rodent Workstand, Rat and Mouse Intubation Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Anesthesia System Modification and Replacement Components
Miscellaneous Machine and Warm Water Pump Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Dual Procedure Circuit and Miscellaneous Replacement Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
”VetEquip Gives Me Gas!” The Famous Tee Shirt Inside Back Cover
V
E T
E
Q U I P
1 - 8 0 0 - 4 6 6 - 6 4 6 3
1
Inhalation Anesthesia Information
First Time Buyer’s Guide
If this is the first inhalation anesthesia system you’ve purchased for
your facility, we invite you to begin/enhance/complete your anesthesia
equipment research with this “What you need and don’t need”
information.
1. If you are only working with rats, mice, cats, ferrets and other like sized
creatures, you do NOT need a CO2 Absorber (a.k.a. rebreathing head,
SodaSorb container) on your anesthesia machine.
2. You need a “carrier gas” supply. This gas, usually oxygen or medical air,
carries the anesthetic vapor into the patient’s lungs as it breaths. Its pressure,
as it is stored in a cylinder, powers the anesthesia machine.
3. You need a carrier gas flowmeter that will allow you to deliver the carrier gas
as slowly as 1⁄2 liter per minute to a nosecone or as fast as 1 to 4 liters per
minute to an induction chamber.
4. You need a good, reliable and valid vaporizer. A vaporizer is to an anesthesia
machine as an engine is to a car. It needs to be “agent specific,” originally
manufactured for the agent you want to use. The only time that fact does not
hold true is when a halothane vaporizer is dedicated to isoflurane or visa versa.
5. You need an oxygen flush assembly. If you are unable to “flush out” your
induction chamber you will have no choice but to always work in a nonrecirculating fume hood or a chemical fume hood with an activated carbon
filter. If any vendor tells you otherwise, ask for independent test results
showing their chamber can be precharged and opened or unflushed and
opened without everyone in the procedure area being exposed above OSHA’s
Permissible Exposure Limits (PELs).
6. You need an induction chamber with a positive pressure seal. If you don’t have
one, see #5 above.
7. You need activated carbon filters that are reliable. The PEL for isoflurane is 2
parts per million (ppm), the human nose can’t detect isoflurane until it reaches
50 ppm. It’s important to be confident that your carbon filter is working even
when you can’t smell the agent.
8. You need a non-rebreathing circuit that delivers the agent saturated gas from
the machine to the patient, and then collects and contains the waste gas from
the patient to an adequate disposal system.
9. In the United States, isoflurane Permissible Exposure Limits are an OSHA
compliance issue. You must take whatever measures are necessary to keep
your procedure area below the PEL of 2 ppm. Neither your procedures, the
species you use, the things you’re studying, the facility you’re working in, or
the company, agency or educational institute you work for have any affect on
this fact; you must comply with the 2 ppm PEL.
2
1 - 8 0 0 - 4 6 6 - 6 4 6 3
"I have 12 IMPAC's at
our facility.
I have no reservation
about training new
users on VetEquip
machines, even for
those that have never
used gas anesthesia
before."
– Kathy
Associate Scientist
Animal Pharmacology
"I've been using
VetEquip for 18 years
- they have a topnotch maintenance
program.
VetEquip sets the
standard that others
try to achieve and I
want that level of
quality."
– Suzette, RLATG, RVT
Senior Manager
Lab Animal Resources
V
E T
E
Q U I P
Anesthesia Machine
This term includes the frame, yoke(s), flowmeter(s),
vaporizer(s), oxygen flush assembly and all hoses and
connections.
Regulator(s)
The regulator(s) are responsible for reducing the supply tank
pressure to specified levels.
Oxygen Flush Assembly
The flush assembly is responsible for purging all waste gas from the induction chamber.
Vaporizer
The vaporizer is responsible for changing the liquid agent to a vapor which the patient can inhale. It then
delivers the vapor into the moving steam of oxygen in controllable amounts.
Reconditioned Vaporizer
In human medicine, a vaporizer that has been properly cleaned and calibrated for its specific agent and is
ready for clinical use. In veterinary use, it could refer to simply a “used” vaporizer or a vaporizer which has
been re-labeled for an agent other than the agent for which it was designed. It is recommended that proper
questions be asked to determine each sellers’ definition of the term.
Remanufactured Vaporizer
May be used in lieu of “reconditioned”, frequently means some internal parts are new and some used. Often
the new and used parts are from different agent-specific vaporizers, e.g. enflurane rotor valve inside an
isoflurane casing. May be used to describe a vaporizer whose only new part is an isoflurane dial while the
rest of the vaporizer is entirely used enflurane. It is recommended proper questions be asked to determine
each sellers’ definition of this term.
Service Definitions
Service
A term reserved for any unscheduled work and any repairs directly related to a specific problem. “Service”
and “Preventative Maintenance” are occasionally used interchangeably. “Service” is done on an “as
needed” basis. “Preventative Maintenance” is regularly scheduled.
Preventative Maintenance Service (P/M)
Annual inspection including checks of all components for proper operation and potential problems.
Identification and prevention of possible future breakdowns. Replacement of rubber or other disposable
goods.
Calibration
Calibration indicates a vaporizer has been set to standard measuring graduations, under a variety of
conditions. Internal components are cleaned of foreign matter and contaminents, new gaskets, seals and
wicks are installed. The calibration process takes place while operating under different flowrates,
temperatures and time frames.
Inhalation Anesthesia Information
Anesthesia System Components Glossary
Efficacy Test
A meter reading of vaporizer output, determining whether or not the output matches the dial reading at both
high and low oxygen flows.
Certification
Documentation that all components of the machine have been inspected and perform to manufacturer’s
specifications. Guarantees that the components are working properly and should continue to perform as
expected for another year.
V
E T
E
Q U I P
1 - 8 0 0 - 4 6 6 - 6 4 6 3
3
Inhalation Anesthesia Information
VetEquip Anesthesia Book
The “Need To Know” book. Have you wondered what a “MAC” value is? How is it determined and what factors affect
it? Is your anesthesia machine going through more isoflurane than you think it should? How much should it be using?
What is the OSHA recommendation for anesthesia waste gas? Do you need an MSDS for isoflurane on file? How about
one for the activated carbon in that disposable canister? Did you know you can keep that little nosecone in position with
a piece of dental floss? Are you keeping track of how much waste gas you’re exposed to? How do you do that anyway?
Need a sign out sheet for your departmental anesthesia machine? Wondering if you machine is due for service? When
is a machine due; once a year? Every six months? All these answers and more can be found in the VetEquip Anesthesia
Book.
The book is a 3 ring binder to which you can add any information you may need. The Book is included with every Lab
Animal Anesthesia System or can be purchased separately. When The Book comes with your Lab Animal System, it will
include manuals and protocols for that specific system.
999999
4
1 - 8 0 0 - 4 6 6 - 6 4 6 3
VetEquip Anesthesia Book
V
E T
E
Q U I P
This 45 minute DVD is an excellent training film. Created by VetEquip in cooperation with Columbia University
Center for Biomedical Communication with oversight by a representative of the AALAS On Line Learning Center.
It qualifies the viewer for one unit of AALAS CE. Every component of a traditional anesthesia machine is described
with clear instructions on how and why it is necessary. A basic rat anesthesia protocol is followed step by step.
Special attention is given to waste gas control throughout. The DVD is included with every VetEquip Anesthesia
Book, or can be purchased separately.
999998
V
E T
E
Q U I P
Inhalation Anesthesia Information
Inhalation Anesthesia 101 for the laboratory animal environment
Anesthesia 101 DVD
1 - 8 0 0 - 4 6 6 - 6 4 6 3
5
Complete Anesthesia Systems
The VetEquip COMPAC5
A revolutionary anesthesia system that combines the best features of every VetEquip system! The COMPAC5 has two
independent breathing circuits and one to three independent vented induction chambers.
• All circuits, chamber or breathing, are independent of each other
• All circuits have a “flip-switch” choice of 1⁄2 LPM, 1 LPM or OFF
• Chambers are heated with standard warm water pump
• All chambers and circuits are vented; no pollution, no chamber flushing
• Set it on a counter top, carry it to the next room, tuck it in a cupboard, it’s 13” x 13” x 15”
901812
VetEquip COMPAC5 Complete Anesthesia System
Includes Warm Water Pump (# 983105) and Extract All (# 933105)
Ask About Available Trade In Opportunities!
6
Combine the safety of the new COMPAC5 with the convenience of
complete portability. Exhaust cabinet and 4-wheeled, counterbalanced leg assembly, combined to create a mobile platform for your
COMPAC5. Smooth rolling double-wheeled castors allow you to move
your unit to any procedure room in your facility. Available as a standard
cabinet base or with fold-down shelf surfaces on each side of unit for
the ultimate worstation. Add a single, dual, or triple O2 yoke assembly
(see pg. 14) to make full use of the mobile units’ capabilities. Cabinet
also doubles as storage unit for frequently needed items.
901814
Mobile COMPAC5 Multi Paatient
Anesthesia System
As Shown
901816
Mobile COMPAC5 Multi Paatient
Anesthesia System
With dual 12” X 12” fold down shelves
The VetEquip COMPAC5 Accessories
The VetEquip COMPAC5 is designed to be a complete system when used with your existing warm water pump and inhouse or freestanding exhaust systems. If you do not currently have one or both, the following equipment is available
to complete your COMPAC5 System:
Extract-All Bench Top
Extract-All Cabinet
or
933105
Extract-All Cabinet
Cabinet has double filters
1
18” x 42 ⁄2” x 13 not incld.
rear filter
Filter Mate
Portable Extractor
or
933101
Extract-All Bench Top
1
12” x 10 ⁄2” x 7” not incld. filter
935101
Complete Anesthesia Systems
The VetEquip Mobile COMPAC5
Filter Mate Portable Extractor
14” x 23” x 223⁄4”
Up to 250 CFM
Houses a carbon based filter cell,
surrounded by a negative pressure
plenum to capture and re-filter any leaks
Warm Water Pump
T-Pump provides a large water reservoir and temperature
settings from 85˚ to 107˚ F with a high flow rate to assure
uniform temperature across the pad. Has two overheat
safety devices as well as a “tip over” shut off. Illuminated
on / off switch and folding handle.
983105
V
E T
E
Q U I P
Gaymar Warm Water Pump
1 - 8 0 0 - 4 6 6 - 6 4 6 3
7
Complete Anesthesia Systems
RC2 - Rodent Circuit Controller
All oxygen flowrates are independently preset: Circuits 1, 2, 3, and 4 preset to 1⁄2 lpm:
• Any combination of circuits can be used without
readjusting oxygen flows
• All circuits are unaffected by the resistance
occurring in split lines
• Any combination of non-rebreathing circuit styles
can be used
• Any circuit length or combination of lengths
can be used
• Sufficient oxygen without excessive waste
• Oxygen flows cannot be set too high causing leaks
around nosecones or facemasks
Circuits 5 and 6 preset to 1 lpm with Oxygen
Flush Assemblies:
• Faster inductions, chamber saturation takes only 1
or 2 minutes
• Flushing saturated chambers complies with OSHA
waste gas recommendations
922100
RC2 - Rodent Circuit Controller System
12” wide, 6” deep, and 12” high
Includes: vaporizer; 2 induction chambers; 4 breathing circuits;
4 nose cones; 6’ 22mm evacuation tubing; 10‘ O2 hose and 6
VaporGuard filters
System Status
Indicator tells if
the RC2 is on or
off at a glance
Specific flow
to each
circuit,
controlled by
individual
on/off switch
Oxygen flush
Assembly for
OSHA waste
gas compliance
• Perfect for teaching procedures, without teaching
specifics of inhalation anesthesia
• Ideal for multiple, simultaneous procedures
• Perfect for multiple investigators doing complex
procedures with no time for adjusting oxygen flows
• Customize this system by selecting your choice of
chamber sizes and nosecone sizes
922120
8
Mobile RC2 - Rodent Circuit Controller System
Mobile RC2 takes advantage of our time-tested anesthesia machine frame. Mount your RC2 to the extruded aluminum, counterbalanced, body for the ultimate in portability. Allows the potential for having single, dual or triple O2 tanks directly on the
machine (see pg. 14)" RC2 unit can be easily removed from frame for situations where space is limited.
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
• Designed specifically for high volumes of procedures
• 2 Breathing Circuits and 4 Induction Chambers allow investigator flexibility in designing custom “assembly
line” protocols
• Each of the 6 circuits is equipped with a simple “ON-OFF-FLUSH” switch to reduce operator errors and speed
procedures
• Separate O2 and CO2 flowmeters and chamber make euthanasia, O2 assisted recovery and O2 / CO2 anesthesia
accessible and precise
• Line pressure gauges create constant easy oversight of in-house gas supply
• Single waste gas port and tube for less counter top clutter
901808
Complete Anesthesia Systems
6
IMPAC
IMPAC6 - Integrated Multi Patient Anesthesia Center
22” wide, 18” deep, and 28” high
Weight 50 lbs.
V
E T
E
Q U I P
1 - 8 0 0 - 4 6 6 - 6 4 6 3
9
Complete Anesthesia Systems
Laboratory Animal Anesthesia Systems
Safety, Quality and Economy
• Every component is chosen for durability, strength and safety
• All systems guaranteed for 7 years
• All vaporizers completely new and agent specific
• Aluminum frames with baked-on surface for scratch and stain resistance
• Clear acrylic induction chamber for clear views of the patient
• Positive pressure seals eliminate chamber leakage
• The Dual Procedure Circuit allows assembly line productivity
• Used with proper protocols, badge monitoring results in “no detectable amounts found”
• You add only: carrier gas, liquid agent, and animals
Every “Lab Animal System” comes complete with a ten foot high-pressure oxygen hose, frame, flowmeter,
oxygen flush assembly, vaporizer, breathing circuit, chamber, nosecones, waste gas evacuation tubing and two
VaporGuard filters.
Included with all
Laboratory Animal Anesthesia Systems
901807
10
V-10 Mobile Cart Lab Animal System
19” x 19” x 50.5” high, 60 lbs.
9” x 19”shelf with 3⁄4” lip
1 - 8 0 0 - 4 6 6 - 6 4 6 3
901806
V-1 Table Top Lab Animal System
8” x 11” x 14” high, 15 lbs.
V
E T
E
Q U I P
901810
V-9 Wall Mount Lab Animal System
Includes all accessories shown on page 10
901809
V-10/A Mobile Cart Lab Animal System
With CO2 Absorber
Includes all accessories shown on page 10
901811
Complete Anesthesia Systems
Laboratory Animal Anesthesia Systems
V-9/A Wall Mount Lab Animal
System With CO2 Absorber
Includes all accessories shown on page 10
V
E T
E
Q U I P
1 - 8 0 0 - 4 6 6 - 6 4 6 3
11
Anesthesia Machines
Portable and Mobile
All Table Top, Mobile Cart, and Wall Mount Machines have an aluminum frame with a baked on finish
that resists scratching and staining, a 0 to 4 lpm oxygen flowmeter, an oxygen flush assembly, vaporizer
inlet and outlet, predrilled holes to fit most vaporizer models, a 10 foot, high pressure, oxygen hose with
DISS (female) fittings, all necessary tubing for component connections and a standard common outlet.
These units do not include vaporizers, regulators, breathing circuits or chambers.
901801
Table Top (V-1)
One-handed carrying with weight-balanced handle
Wide, flat, rubber bottomed feet eliminate tipping
Use with “E” cylinder or “H” cylinder
Ideal for limited floor space
Easy storage in a locked cabinet
901804
Mobile Cart (V-10)
Shelf 19” by 9” with a 3⁄4” lip
4 wheel, 2 leg design for more stability
Handle doubles as a hose and breathing circuit hanger
Cross bar holds E cylinder regulator assemblies
901802
Wall Mount (V-9)
Compact, saves floor and counter space
Easily bolts to most surfaces
Easy to reach and see, but out of the way
901805
Mobile Cart (V-10/A)
Same as V-10 with a 1500cc capacity CO2 Absorber
Suitable for larger animals and rebreathing circuits
Easily adapted to ventilators
901803
Wall Mount (V-9/A)
Same as V-9 with a 1500cc CO2 Absorber
Suitable for larger animals and rebreathing circuits
Easily adapted to ventilators
12
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
We sell only completely new vaporizers, specifically manufactured
for the agent for which they are labeled.
We do not sell vaporizers that have been “remanufactured”,
“converted”, “rebuilt” or “re-serviced” from old enflurane vaporizers.
“Tec3” style vaporizers all look the same on the outside, different manufacturers have different quality standards for
internal components. We use only the highest quality vaporizer manufacturer.
911103
911106
Isoflurane - Funnel-fill
Sevoflurane - Funnel-fill
911104
911107
Vaporizers
Vaporizers
Isoflurane - Pin-indexed
Sevoflurane - Pin-indexed
Requires pin index fill device
Vaporizers for other agents available – please contact us.
Anti-Spill Bottle Top
911111
911112
911113
Pin Index Bottle Fill Device
Isoflurane
Halothane
Sevolflurane
911117
911118
911121
Isoflurane
Halothane
Sevoflurane
Tec3 Style Vaporizer Inlet and Outlet
911124
1 - 8 0 0 - 4 6 6 - 6 4 6 3
Inlet
911125
Outlet
V
E T
E
Q U I P
13
Carrier Gas Information & Supplies
Carrier Gas Supplies
“Carrier gas,” usually oxygen, is supplied from a cylinder, large or small, in the procedure room, on the anesthesia
cart, or piped through the walls.
If your facility has “piped in” oxygen, you will see either wall plate outlets, gas faucets or drop lines in your procedure
area. See page 15 for the appropriate hose fitting.
If you do not have piped in oxygen, you will need to have a cylinder in your procedure area. Standard sizes are “E”
and “H”. Most facilities do not own the cylinders, they rent them from a gas supplier. The supplier will rent the
cylinders but not the regulators that are required to lower the cylinder pressures to 50 psi. Anesthesia machines need
non-adjustable regulators that are preset to 50 psi.
The chart below compares E and H cylinders:
E-Cylinder
H-Cylinder
Height
30”
54”
Diameter
3.5”
8.5”
Volume - Liters
651
7107
Initial Pressure
2200 PSI
2200 PSI
11
118
Approx. Hrs Use @ 1 LPM
Regulators
All regulators are gas specific, preset to 50 psi and have a DISS, male, gas specific, outlet.
D & E Cylinder
901305
901302
901304
901309
Oxygen
Carbon Dioxide
Nitrous Oxide
Medical Air
201744
“E” Cylinder Wrench
with security Chain
901301
Gasket, “E” Cylinder
H & M Cylinder
901306
901308
901304
901307
Oxygen
Carbon Dioxide
Nitrous Oxide
Medical Air
Sold individually
E Cylinder yoke/regulator assemblies for V-10 and V-10/A machines
932021
932081
14
Oxygen, single
CO2, single
1 - 8 0 0 - 4 6 6 - 6 4 6 3
932022
932032
Oxygen, double
CO2, double
V
E T
E
Q U I P
Quick disconnects provide a fast and easy method for moving an anesthetic machine without having to turn the gas
supply on or off. They can be installed anywhere in the high pressure hose between the machine and the gas supply.
The female (coupler) end is a check valve and is connected to the supply side of the hose. The male (adapter) end is
connected to the machine side of the hose.
Find the connection type you need from the photos below and match that to the part number list.
Ohmeda Coupler
Ohmeda Adapter
Oxyquip Coupler
Oxyquip Adapter
Chemtron Coupler
Chemtron Adapter
Puritan Coupler
Puritan Adapter
Ohmeda
931506
931507
931512
931513
Chemtron
Oxygen Coupler x 1⁄8” FPT
Oxygen Adapter x 1⁄8” MPT
CO2 Coupler x 1⁄4” Hose Barb
CO2 Adapter x 1⁄8” MPT
Oxyquip
931511
931514
931509
Puritan
Oxygen Coupler x DISS Male
Oxygen Adapter x DISS Male
931516
931515
931510
Hose
• Color coded, nylon reinforced, ⁄4” ID, conductive
high pressure gas supply hose. Hose assemblies
can be custom made to exact specifications.
931503
931508
931504
931502
931501
E T
Oxygen Coupler x 1⁄8” FPT
Oxygen Coupler x 1⁄4” MPT
Oxygen Adapter x 1⁄8” MPT
Outlet Stations
1
V
Oxygen Coupler x 1⁄8” FPT
Oxygen Adapter x 1⁄8” MPT
931517
E
Oxygen, Green
Carbon Dioxide, Grey
Evacuation, Clear
Nitrous Oxide, Blue
Medical Air, Yellow
Q U I P
• Recess mounted or surface mounted
• Single or multiple gas configurations
• Gas Specific
• Connection type specific
931505
Carrier Gas Information & Supplies
Quick Disconnects
Outlet Station for Gas Supply
Specify gas type(s), connection type and mounting style
1 - 8 0 0 - 4 6 6 - 6 4 6 3
15
Non-rebreathing Circuits
Breathing Circuits
Breathing circuits carry the agent saturated gas from the anesthesia machine to the patient and from the
patient to the waste gas evacuation system. They are divided into 2 categories, rebreathing and nonrebreathing.
Non-rebreathing Circuits
Non-rebreathing circuits are not used with CO2 absorbers or standard bellows ventilators. One tube carries the gas
from the machine to the patient where a connection holds a facemask, nosecone or endotrachael tube. A second,
larger diameter “exhaust down tube” also acts as a reservoir of breathable gas for the patient. Larger animals, 5 lbs
and up, can be safely maintained on a non-rebreathing circuit by adding a “reservoir bag” between the down tube and
the evacuation system.
Modified Bain - 1⁄16” ID fresh gas tube
inside the 1⁄4” waste gas tube. Nose
end flared to create a built-in
nosecone.
9mm flared end
12.5mm flared end
14mm flared end
921461
921462
921463
921411
921410
Adult Bain, 60”
Pedi Bain, 45”
⁄4” fresh gas tube within 22mm
waste gas tube
1
921412
Mapelson E
1
⁄4“ fresh gas tube outside the 22mm
waste gas tube
921401
921425
Bag Evacuation Valve
Complete Non-Rebreathing Circuit
For use with animals up to 15 lbs.
With 1.0 liter reservoir bag and evacuation valve
16
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
• Create a snug seal around the animal’s nose
• Cut dead space to a minimum
• Allows access to eyes, ears and top of head
• All sizes can be stored in sterile instrument solution
• Fits all standard non-rebreathing circuits
921609
921612
921614
Small to Medium Mouse, 9mm
Large Mouse, Small to Medium Rat, 12mm
Large Rat, 14mm
Finger Cots
921610
Finger Cot Nose Cone Kit
Includes 2 19x22mm adapters
and 12 finger cots
190501
Finger Cot, Large,
Black Latex
Finger Cot installation on Standard Bain
Non-rebreathing Circut
Finger Cot installation on Standard
Mapleson E Non-rebreathing Circut
Facemasks
• Clear cone for full visualization of muzzle
• Flexible and replaceable rubber diaphragms
• Standard 15mm connector fits all breathing circuits
921431
921430
921429
921428
921427
Small Rodent Mask
Medium Rodent Mask
Large Rodent Mask
Small Canine Mask
Large Canine Mask
921415
921416
921417
921418
921419
Nosecones and Facemasks
Bubble Tubing Nosecones
Replacement Diaphragm
Replacement Diaphragm
Replacement Diaphragm
Replacement Diaphragm
Replacement Diaphragm
Stereotaxic Frame Nosecones
• Fits most stereotaxic frames
• Allows use of bite bar and ear bars
• Locks onto frame
921432
V
E T
E
Q U I P
Mouse Size
921434
Rat Size
1 - 8 0 0 - 4 6 6 - 6 4 6 3
17
Chambers
Anesthesia Induction Chambers
• Induction Chambers that don’t pollute the
procedure area
• Non-skid feet
• Positive pressure gaskets at lids
• Both ports on one side to reduce tubing in
procedure area
• Standard anesthesia size inlet and outlet ports
• Clear, durable, acrylic construction
• Ports positioned above level where sleeping
animals could create occlusions
• Large, easy to use latches
941443
1 Liter Chamber
705103
Replacement Gasket
2 Liter Chamber
705104
Replacement Gasket
7 Liter Chamber
705105
Replacement Gasket
15 Liter Chamber
705106
Replacement Gasket
(ID 3.75”W x 4.50”D x 3.75”H)
941444
(ID 3.75”W x 9.00”D x 3.75”H)
941448
(ID 8.25”W x 8.75”D x 5.75”H)
941454
(ID 15.00”W x 7.50”D x 7.7”H)
Vented Induction Chambers
Constant exhaust over the opening of these chambers assure investigator safety.* Excess anesthetic vapor is
completely captured during all phases of the induction process, even while removing the animal. Connect to nonrecirculating exhaust, or pair with one of our evacuation units on pg. 26 for the latest in anesthesia safety. Available
in the standard 2-Liter size and introducing our new 7-Liter model for larger animals or groups of animals. Convenient
slide top lid and standard inlet and outlet fittings. 6ft of 30mm evacuation tubing included.
*Independent test data available upon request @ 800-466-6463 or via email at [email protected]
942102
2-Liter, OD 5.5”W x 13.0”D (slopes) 3.2” to 4.2” H
941447
7-Liter Vented Induction Chamber
Fresh gas inlet–standard15mm x 22mm
Waste gas outlet–30mm OD
Fresh gas inlet–standard15mm x 22mm
Waste gas outlet–30mm OD
Replacement Chambers
6
5
IMPAC
COMPAC
941446
941456
941455
IMPAC6, Divided
IMPAC6, Undivided
704306
704305
704304
704303
18
1 - 8 0 0 - 4 6 6 - 6 4 6 3
COMPAC5 Chamber Complete, 2 dividers, 5 lids
COMPAC5 Chamber Divider
COMPAC5 Chamber Lid, large
COMPAC5 Chamber Lid, medium
COMPAC5 Chamber Lid, small
V
E T
E
Q U I P
Rebreathing circuits require a CO2 Absorber and can be used with a ventilator. Two hoses or tubes are connected to
the anesthesia machine. They meet in a “Y” at the patient’s nosecone, endotracheal tube or face mask. The gas is
delivered to the patient via one hose and returned to the machine via the other. The gas then passes through the CO2
absorber where CO2 is removed, fresh gas is then added to the flow, and the gas goes back to the patient again.
Open ends of hoses are standard 22mm, designed to push on to the inhalation and exhalation ports of any standard
anesthesia machine. The “Y” piece at the patient end connects to any elbow, endotrachael tube, face mask or
nosecone.
921413
Pediatric set, 36” hoses,
5
⁄8” ID, 22mm fittings
921414
Adult set, 48” hoses,
1” ID, 22mm fittings
Rebreathing Circuits
Rebreathing Circuits
Reservoir Bags
Reservoir bags are used on both rebreathing and non-rebreathing circuits. With rebreathing circuits, the bag hangs
from the CO2 Absorber, creating an extra reservoir of “breathable” air. With non-rebreathing circuits, the bag attaches
to the end of the waste gas tube, again creating an extra reservoir of “breathable” air. Since the waste gas tube itself
is a reservoir of breathable air, smaller animals, such as rodents, may not need the additional reservoir of a bag.
Standard Reservoir Bags
22mm neck with a flat oval shape
921402
921403
921404
921405
921406
921407
Reinforced Reservoir Bags
22mm stretch neck and reinforced shoulder
⁄2 liter
1 liter
2 liter
3 liter
4 liter
5 liter
1
921471
921472
921473
921475
Standard
V
E T
E
Q U I P
1 liter
2 liter
3 liter
5 liter
Reinforced
1 - 8 0 0 - 4 6 6 - 6 4 6 3
19
Rebreathing Machine Components
Rebreathing Machine Components
A “rebreathing circuit” allows the oxygen (or medical air) and anesthetic vapor mixture from the anesthesia machine
to be delivered to the patient, contained and collected as it passes (or is exhaled by) the patient, has the carbon
dioxide removed from it, and then is re-delivered to the patient.
The reasons for using this anesthesia delivery and re-delivery method are: the total amount of anesthetic and oxygen
(or medical air) used is reduced; some heat lost with exhaled air is re-introduced to the patient, reducing the overall
heat loss; some moisture lost with the exhaled air is re-introduced to the patient, lessening dehydration.
The “rebreathing” method is rarely used with small animals as total air volume passing through the patient’s lungs
must be significant for the physiologic advantages (heat and moisture retention) to be effective. For those animals in
excess of 35lbs to 50lbs (or 13kg to 20kg,) the advantages can be effective.
CO Absorber
2
For either the Mobile Cart or Wall Mount Machine. Holds the CO2 absorbent, and with its uni-directional valves in the
inhalation and exhalation ports, forces the moving gas to follow a circular pattern to and from the patient.
• Direct reading manometer displays pressure within the
breathing circuit
• Anti-pollution (pop-off) valve allows breathing circuit
pressure adjustments
• 1500cc absorbent container, easily removable,
durable, clear
901751
The Anti Pollution Valve (Pop-Off) interfaces between the anesthesia
machine and the waste gas evacuation system. It collects the waste
gas from the CO2 absorber, allows in-circuit pressure adjustments and
has a 19mm port for a waste gas tubing attachment.
401733
20
CO2 Absorber
Anti-Pollution (Pop Off) Valve
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
As more facilities opt for beginning CO2 euthanasia with measured percentages of O2 and CO2, economically priced
systems become necessary. The Complete 3 Stage Solution System, with its individual O2 and CO2 flowmeter can be
used for:
• Oxygen supported recovery
• Short term anesthesia
• Humane euthanasia
901703
3 Stage Solution System,
E or D Cylinders
901702
(cylinders not included)
3 Stage Solution System,
H or M Cylinders
(cylinders not included)
Both Setups Include
12lpm CO2 Flowmeter/Regulator assembly, 15lpm O2 Flowmeter/Regulator assembly, Recovery/CO2 Mouse Housing
Cage, Universal lids for rat and mouse cages, 8’ tubing which connects to Flowmeter and universal lids. E or D
Cylinder set up includes cylinder wrench (see pg. 14) and dual cart.
941441
941442
Euthanasia Systems
3 Stage Solution System
Chamber, Recovery/CO2
Mouse Housing Cage
Universal Lid, Mouse Cage
941445
11.5” x 7.25”
Universal Lid, Rat Cage
211200
Dual “E” Cylinder Cart
18.75” x 9.75”
Universal lids fit on any standard mouse or rat housing cage. Excellent for either O2 recovery or CO2 euthanasia. No
waste gas evacuation system is necessary for CO2 and/or O2. These chambers do not have positive pressure seals
and consequently cannot be used for anesthesia induction.
401722
CO2 flowmeter 0 to 12 lpm
401720
401745
12lpm CO2 Flowmeter/Regulator
assembly, E or D Cylinders
12lpm CO2 Flowmeter/Regulator
assembly, H or M Cylinders
401746
401740
V
E T
E
Q U I P
O2 flowmeter 0 to 15 lpm
(As Shown)
(As Shown)
401748
15lpm O2 Flowmeter/Regulator
assembly, E or D Cylinders
15lpm O2 Flowmeter/Regulator
assembly, H or M Cylinders
1 - 8 0 0 - 4 6 6 - 6 4 6 3
21
Waste Gas Information
Anesthetic Waste Gas Overview
Anesthetic waste gases include any gas from the anesthesia machine that passes the patient without being inhaled,
as well as any gases the patient exhales. Trace amounts can pollute the procedure area due to leaking equipment,
spills while filling vaporizers, saturated charcoal canisters and inappropriate system use. It is assumed that prolonged
and repetitive exposure to anesthetic gases can be toxic. Consequently, NIOSH has recommended Permissible
Exposure Limits (PEL’s) for anesthetic agents. The PEL established for halogenated anesthetics is 2 parts per million
(PPM).
Containing Anesthetic Gas
With respect to specific methods or products, OSHA makes no recommendations as to how to comply with these
limits. All anesthetic gases must be contained as they travel to and from the patient. Since gas is constantly being
delivered to the patient, there is always an excess that needs to be either evacuated from the area or filtered such
that all the anesthetic agent is removed.
Evacuating Gases
Evacuation of waste gas from the area without filtering means that the gas must continue to be contained until it
can be released to the outside atmosphere. Channeling to the outside requires oversight to ensure that all
connections are leak free. Testing must be done to assure that the number of bends in the evacuation line, as well
as the overall length, does not cause resistance to the flow of gas from the anesthesia machine. Evacuation lines
must be checked periodically to assure they are clear of obstructions.
Filtering Gases
Filtering means the gas is run through an adsorbent material such as activated charcoal, which collects and holds
onto the anesthetic molecules. Once the charcoal is saturated, anesthetic gases which pass through will NOT be
adsorbed. Protocols should included weighing small charcoal canisters before and after each use.
Passive vs. Active Evacuation
Passive evacuation occurs when the gas flow from the anesthesia machine pushes the waste gases to the outside
atmosphere or a filtering canister. Active evacuation involves applying negative pressure (suction) to the evacuation
circuit. In the passive system, a leak in the evacuation circuit could cause the waste gases to leak ”outward” into
the procedure area. In the active system, if negative pressure reaches the patient’s nosecone, it may pull the
anesthetic gases past the nosecone, depriving the patient of the delivered concentration of gas. If operating with a
loose fitting mask, room air may be pulled into the nosecone area, diluting the set concentration of anesthetic.
In-facility Vacuum, Fume Hoods & Down Draft Tables
There are two common ways to use active evacuation. The first utilizes an in-facility exhaust system and a
scavenging interface device. Tubing from the in-house exhaust system and exhaust tubing from the breathing circuit
are connected directly to the interface. This device constantly attenuates pressure such that negative pressure is
never applied directly to the anesthesia machine or patient. It should also have a provision to avoid accidental
positive pressure build-up in the breathing circuit. This is the standard method in human hospital surgery suites. The
second method is to apply the negative pressure to the procedure area (e.g. fume hoods and down draft tables) in a
manner that allows any waste gas to be pulled into the stream of moving air, but does not apply negative pressure to
the patient or anesthesia system. This method is very popular in rodent surgery as it lends itself to the use of less
obtrusive breathing circuits.
Monitoring Anesthesia Exposure
Halogenated anesthetics, including desflurane, sevoflurane, isolfurane, halothane, and methoxyflurane are subject
to NIOSH’s Recommended Exposure Limits (REL)’s. The REL for these gases is 2 parts per million (PPM). This limit is
based on a 1978 NIOSH study examining the effects of prolonged and repeated exposure to methoxyflurane and
halothane. Although no similar study has been done with more current agents, we must still comply with the
standard of 2 PPM.
22
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
OSHA enforces the NIOSH recommendation without outlining any
specific method for monitoring these levels. OSHA inspectors use
canisters to collect an air sample and send the sample back to a
laboratory for analysis. Safety assessment personnel at some
larger facilities are using expensive real-time monitors. Analytical
chemical laboratories, which issue and analyze badges, use a
time-weighted average or other method of analysis to determine
exposure. AAALAC’s site inspection committee has requested proof
of compliance. Without a specific guideline from OSHA, some type of
monitoring is always better than none. It has been our experience that
OSHA has been willing to accept all of these methods.
"I've worked with
VetEquip for years.”
Real-time monitors
Real-time monitors show exactly how many PPM’s are being detected as the
test is being conducted. While precise, the spiked readings tend to be higher
than the time-weighted average from the badge readings. The monitor sensors
can be placed directly at nosecones or induction chamber lids where readings
will be higher than the exposure at the investigator’s breathing area, many
inches away. The expense of real-time monitors may make them costprohibitive.
Badge Analysis
Badges are the monitoring method of choice for most facilities. The badge is
clipped to the user’s shirt collar where it adsorbs samples of the air near the
breathing area. The badge is then sent to a laboratory for analysis and
reporting.
I recommend VetEquip
whenever anyone is
setting up a lab
because they know
the anesthesia end.
Waste Gas Monitoring
Testing Methods
Frequency
Monitoring via badges, air samples or real-time devices is not done daily or
weekly. Most facilities opt to have one person in each procedure area wear a
badge once every six months. You and your safety assessment committee may
opt for more frequent monitoring if results exceed PEL’s, procedure protocols
change, if there is a change in personnel or equipment, or as needed.
I feel VetEquip partners
with me and has an
interest in what I'm doing,
as opposed to wanting to
just sell me something."
– Diane, RVT, LATG
Monitoring Badge
Research Coordinator
Radiological Sciences
Laboratory
931443
V
E T
E
Q U I P
Waste Gas Monitoring Badge and Analysis Report
1 - 8 0 0 - 4 6 6 - 6 4 6 3
23
Waste Gas Control
Waste Control Valves
The scavenging interface serves to prevent potentially dangerous increases or decreases of pressure in the
anesthetic waste gas disposal system from reaching the patient’s breathing circuit.
Positive pressure relief must be provided to protect the equipment and patient if occlusion of the scavenging system outlet
occurs. If the scavenging system outlet becomes occluded, the positive-pressure relief vent opens to prevent
transmission of high pressure to the breathing circuit.
Negative pressure relief is needed to prevent negative pressure (suction) generated by the disposal system from
reaching the patient’s breathing circuit.
A reservoir is necessary to allow the scavenging system to accommodate an increased volume of excess anesthetic
gas, which may transiently exceed the per-minute removal capacity of the system. It may also serve as a monitor of
the scavenging system if the reservoir is a distensible bag. Overdistension of the bag could indicate inadequate
function of the system and the need to adjust the needle valve to allow more gas to flow through.
931440
Scavenging Interface Kit
Includes: 3L reservoir bag with 19mm neck, 6 each of 1/4” ID suction hose
and 19mm evacuation tubing.
931439
921405
Scavenging Interface Valve only
3.0 Liter Scavenging Reservoir Bag
VaporGuard Filter
931401
VaporGuard Filters
Sold in cases of 8
*Independent test data available upon request @ 800-466-6463 or via email at [email protected]
24
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
• Connects to any standard warm water pump for maintenance of body heat without danger of burns
• Connects to in-house or freestanding evacuation system for collection of any waste gas leaking around
facemasks or nosecones
• Stainless steel surface is an excellent heat conductor ensuring immediate and adequate surface heat
• Stainless steel construction stands up to disinfectants, hand scrubbing and cage washer heat
• Replaceable filters and removable under-table channel cover guarantee easy and thorough cleaning
• 16”W x 11.5”D x 1.25” H; Weight - 9.5 lbs
Interchangeable slotted and
solid grills allow you to
easily reorient the patient.
Waste Gas Control
DSx Vented, Warmed Surgery Table
Four adjustable tie-downs
Connection to standard warm
water circulation pump
965500
Connection to waste
gas evacuation
DSx Vented, Warmed Surgery Table
*Independent test data available upon request @ 800-466-6463 or via email at [email protected]
DSx Accessories
983105
H20 Pump
V
E
E T
Q U I P
933101
Extract-All Bench Top
933105
Extract All-Cabinet
1 - 8 0 0 - 4 6 6 - 6 4 6 3
25
Waste Gas Control
Self Contained Evacuation Systems
Self-contained recirculating air cleaning systems plug in to any 110 outlet to remove contaminated waste gas
at its source.
Filter Mate
Portable Extractor
or
935101
Extract-All Bench Top
Extract-All Cabinet
Filter Mate Portable Extractor
14” x 23” x 223⁄4” Up to 250 CFM
Houses a carbon based filter cell,
surrounded by a negative pressure
plenum to capture and re-filter any leaks
or
933105
Extract-All Cabinet
Cabinet has double filters
18” x 421⁄2” x 13 not incld.
rear filter
933101
Extract-All Bench Top
12” x 101⁄2” x 7” not incld. filter
Accessories For Evacuation Systems
Filter Mate Portable Extractor (935101)
935105 FilterMate Replacement Filter
935106 FilterMate Thimble Connection
connects FilterMate to existing
house exhaust
Extract-All Cabinet (935105)
933106 Primary Filter
933107 Secondary Filter
933108 Primary Filter refill
933109 Secondary Filter refill
Extract-All Bench Top (933101)
933106 Primary Filter
Vented Induction Chambers
Constant exhaust over the opening of these chambers assure investigator safety.* Excess anesthetic vapor is
completely captured during all phases of the induction process, even while removing the animal. Connect to nonrecirculating exhaust, or pair with one of our evacuation units on pg. 26 for the latest in anesthesia safety. Available
in the standard 2-Liter size and introducing our new 7-Liter model for larger animals or groups of animals. Convenient
slide top lid and standard inlet and outlet fittings. 6ft of 30mm evacuation tubing included.
*Independent test data available upon request @ 800-466-6463 or via email at [email protected]
942102
2-Liter, OD 5.5”W x 13.0”D (slopes) 3.2” to 4.2” H
Fresh gas inlet–standard15mm x 22mm
Waste gas outlet–30mm OD
26
1 - 8 0 0 - 4 6 6 - 6 4 6 3
941447
7-Liter Vented Induction Chamber
Fresh gas inlet–standard15mm x 22mm
Waste gas outlet–30mm OD
V
E T
E
Q U I P
The Downdraft Anesthesia Work Station is specifically designed to provide a small bench-mounted unit with
unrestricted access for those procedures that are difficult to perform in a fume cabinet. The downflow action takes
the contaminated air away from the operator and an audible alarm will alert the operator when the airflow falls to an
unacceptable level.
Features
• No ducting or installation costs
• Integral lighting illuminates the work surface
• All mechanisms in the head are on the clean side of the
filter, with the switches and electrical components being
isolated from any contamination
• The filter clamping mechanism enables the filter to be
easily located and ensures an even seal at the filter face
• The main filter block can be chosen from fourteen
different types which include speciality filters for
vapors of acids, mercury and formaldehyde
• Total airflow = 145 CFM
• Work surface face velocity = 80 FPM
• Charcoal filter is easily removed for regular
weight/saturation checks
Downdraft Anesthesia Work Station, 24”
Replacement carbon filter for 24” DWS
966003 Downdraft Anesthesia Work Station, 36”
966004 Replacement carbon filter for 36” DWS
Other filters available upon request.
966001
Waste Gas Control
Downdraft Anesthesia Work Station
966002
Exhaust
Cut away sides give extra access to the
work surface.
Filter
Air Intake
15.75"
24”DWS—21”W x 17”D
Stainless steel tray is removable for easy
cleaning and access to the pre-filter.
24” DWS—24”W x 24”D x 32”H
Clean air recirculates into the laboratory,
so there’s no heat loss or costly ducting.
Easy to use Control Panel
• Includes visual alarm for low airflow to
indicate pre-filter blockage
• Automatic “Time-in-Use” counter
• Optional electronic monitoring of both
airflow and filter saturation
V
E T
E
Q U I P
1 - 8 0 0 - 4 6 6 - 6 4 6 3
27
Ventilators
Anesthesia Work Station
• Basic Respiration or Volume Ventilator during anesthesia
• Animals from 150gm to 7kg
• Adjustable high pressure limit
• Airway pressure monitor
• Oxygen flush locked with expiratory phase
• Heated rebreathing chamber
• 0 to 100 ml tidal volume displacement tube
• 300 ml CO2 absorber
• Control rate and volume
921255
Anesthesia
Work Station
HEMC 2000 Small Animal Ventilator
• Animals 1-200kg
• Tidal volume range from 20-3000cc
• Time Cycled Respiratory Rates 6-40 bpm
• Maximum working pressure adjustable from 10-60cm/H2O
• Volume constant to compensate for lung compliance changes
• Dual airway pressure alarms monitor peak inspiratory pressure
921761
921762
921764
921765
921766
921767
HEMC 2000 with 300-1600ml bellows
Bellows & Housing 0-300ml
Bellows 1600-3000ml
Housing 1600-3000ml
Bellows 300-1600ml
Housing 300-1600ml
MicroVent 1
• Animals with tidal volumes 0-10ml
• IPPV and High Frequency Oscillatory Ventilation
• IPPV mode allows control of:
- Oxygen flow 50-100mls per minute
- Breaths per minute 75-2400
921760
MicroVent 1
Ventilator
- Breath volume 0-10ml
- Mean Airway Pressure
• Oscillatory Mode:
- Lungs are expanded and held inflated as high frequency
vibrations (750-2400 per minute) cause osmotic O2 - CO2 exchange
without lung movements
28
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
Interface devices have air reservoirs allowing changes in piston intake volumes to occur unaffected by constant
output volumes. There is no lack of air to be pulled into the ventilator and there is no back pressure within the
anesthesia system.
The Universal Control Arm acts as a pressure stabilizing interface,
provides an enclosed, adjustable pop off for excess volumes (easily
connected to your in-house evacuation) and a manometer for
constant viewing of the pressure within the interface circuit.
The Arm can also be used with any non-rebreathing circuit for the
added advantages of the enclosed pop off valve and the manometer.
921451
Universal Control Arm
As diagramed below, a Bain non-rebreathing circuit combined with tubing, filters and ET adapters can be used to
create an interface. This system can be constructed from components found in most labs or purchased as a Complete
Interface System.
921452
Complete Interface System
For piston-style ventilator
V
E T
E
Q U I P
Ventilator Connection
Interfacing Ventilators with Anesthesia Machines
1 - 8 0 0 - 4 6 6 - 6 4 6 3
29
Small Animal Intubation
Rodent Intubation Aids
984102
Rodent WorkStand
984102
Rodent WorkStand, tilted view
The HEMC Rodent WorkStand was developed in collaboration with George A. Vogler, D.V.M., DACLAM of Saint Louis
University Medical School Comparative Medicine Department to facilitate endotracheal intubation and intratracheal
dose instillation and other similar procedures. The WorkStand will support rats, mice and similar small rodents in a
stable and comfortable position.
984104
Mouse Intubation Pack
984106
Rat Intubation Pack
Used with the Rodent WorkStand, each pack is designed to neatly hold all the tools and supplies needed to perform
quick, efficient and minimally traumatic orotracheal intubation of small rodents. Each compartment is labeled for
contents, reordering information and component instructions.
Both Packs include; a specially designed and molded autoclavable intubation speculum, a lidocaine applicator, and
endotracheal tube guide wire, an incisor loop and a brief tutorial video. In addition, the Rat Pack contains scissors,
umbilical tape, and a mirror for the verification of tracheal intubation. The Mouse Pack includes HEMC’s NEW mouse
endotracheal tubes in two sizes.
Otoscopes in 3 quality ranges are available by special order:
MDS, non-rechargeable NICAD batteries. Special Order #000A3748
Welch Allyn, rechargeable NICAD batteries. Special Order #000A3749
Light and easy to handle Welch Allyn, rechargeable LI Ion batteries Special Order #000A3754
30
1 - 8 0 0 - 4 6 6 - 6 4 6 3
V
E T
E
Q U I P
Table Top, Mobile Cart and Wall Mount anesthesia machines can be modified with additional carrier gas flowmeters
and/or with a “low flow” fine calibrated oxygen flowmeter. Other flowmeters are available via special order.
901751
CO2 Absorber
Removable components for easy
cleaning. Enclosed anti-pollution
valve to capture and vent waste
anesthetic gases. Direct-reading
manometer to monitor pressure in
the breathing circuit.
401721
Oxygen, 0 to 1 lpm
Oxygen, 0 to 4 lpm
Oxygen, 0 to 12 lpm
Carbon Dioxide, 0 to 10 lpm
Carbon Dioxide, 0 to 2 lpm
Medical Air, 0 to 5 lpm
Nitrous Oxide, 0 to 4 lpm
983701
Click-Tite Adapters
411723
411722
401726
401735
401730
401728
211200
401719
983701
Short pieces of water hose with a
threaded (male) connection on one end
and click-tite adapters on the other.
941441
Flow Control
Warm Water Pad, 15” X 22”
Translucent; flexible; with leak
proof, click-tite water hose
connections.
Chamber, Recovery/CO2
Mouse Housing Cage
211100
V
E T
E
Q U I P
Dual “E” Cylinder Cart
Replacement Components
Modification and Replacement Components
Single “E” Cylinder Cart
1 - 8 0 0 - 4 6 6 - 6 4 6 3
31
Replacement Components
Modification and Replacement Components
314525
304519
Adapters ET, 6mm Clear
Adapters ET, 6mm, Blue
921412
Mapleson Non Rebreathing
E Circuit
931435
19mm Evacuation Tubing, Blue
22mm Evacuation Tubing, Clear
931436
171434
Latex Conductive Tubing,
1
⁄4” ID
304789
Y Piece, 1⁄4”
tube adapter
941444
2 liter Induction Chamber
901301
304502
Gasket, “E” Cylinder
Adapter, Elbow only,
Mapleson E Breathing circut
921433
172104
Stopcocks
Silicon Tubing, 1⁄4” ID
Sold individually
931530
O2 Hose, 10’,
DISS X DISS
931401
VaporGuard Filters
Included with every LAAS
304507
921609
921612
921614
921400
32
Dual Procedure Circuit, Complete
1 - 8 0 0 - 4 6 6 - 6 4 6 3
Adapter,
22mm Female X
19mm Male
9mm Nosecone
12mm Nosecone
14mm Nosecone
304501
Adapter,
15mm ID X
22mm OD
V
E T
E
Q U I P