SUDS in Holland
Transcription
SUDS in Holland
SUDS in Holland stormwater quality management in densed urban areas Dundee, 11th may 2011 ir. F.C. (Floris) Boogaard, (020) 606 32 50/06-51 55 68 26 e-mail: [email protected]/ Content • Introduction Dutch stormwater management • Stormwater quality management Research on stormwater Innovations in dense urban areas Test method: interactive research • Conclusions and info Dutch sewer management 70% combined sewer systems Disconnecting: • Less sewer overflows • Optimizing sewage plants • Retaining and holding rainwater • Improving surface water Dutch stormwater management The quality aspect of SUDS ‘Storm water is considered to be clean so no treatment is needed for purification’ Dutch stormwater management stormwater is clean? Dutch stormwater management Guidelines for storm water purification Nieuwe lozing bestaand of nieuw gebied category?: Industrial/commercial/residential areas Licht verontreinigde oppervlakken Daken/ gevels - Nieuwe lozing in bestaand of nieuwe gebied vrijliggende voet-/fietspaden; kantorenoppervlakken; schoolpleinen; parkeergelegenheden voor personenauto's (lage wisselfrequentie). Matig verontreinigde oppervlakken - kantoorterreinen; - wijkontsluitingswegen; - woonerven; - winkelstraten; - doorgaande wegen; - busbanen; - parkeerterrein (hoge wisselfrequentie); - parkeerterrein vrachtwagens. Verontreinigde oppervlakken - bedrijfsterreinen; marktpleinen; laad-/ losplaatsen; overslagterreinen; busstation; trambanen; tunnels. How to deal with stormwater? nieuw gebied bestaand gebied - zinken dakgoten - lood & koper in excessieve toepassing nee W VO-vergunning met algemene en specifieke ('coaten') voorschriften zuiveringstechnieken gewenst : bv. - slibafvang, - bodempassage. ja vervangen/ behandelen/ coaten/ voorzieningen ja nee niet afkoppelen vereiste zuiveringstech. - zand- en slibafvang; - bodempassage. vereiste zuiveringstech. - slibafvang; - olieafscheider;* - bodempasage. - niet afkoppelen - verbeterd gescheiden stelsel (VGS) of gelijkwaardige voorziening toepassing van uitlogende materialen ja nee W VO-vergunning met algemene voorschriften W VO-vergunning met algemene voorschriften W VO-vergunning met algemene en specifieke voorschriften W VO-vergunning met algemene en specifieke voorschriften Dutch stormwater management what are the characteristics of stormwater? Database storm water 2011 content: ca 7500 measurements Over 200 locations in the Netherlands with different type of catch area. More then 100 location abroad (European) Dutch stormwater management Research: contaminants in stormwater? ‘Contaminents’: heavy metals, PAH’s Nutriënts compared to ‘MTR-standard’. (Maximaal Toelaatbaar Risico). MTR: green: <= MTR; orange: <2* MTR; red: more than twice MTR. Water quality improvement by SUDS WB 21 categorie afkoppelmethode Specificatie techniek of product Benutting Kleinschalige benutting benuttingsinstallatie - regenton, bergingszak - regenwaterbenuttingsinstallaties Vasthouden Vegetatiedak daktuinen - mos-, sedum-, grasdak - uitgebreide berging op daken Vasthouden/ Bergen Infiltratie Wadi’s, bermfiltratie bovengronds - “ - halfverharding, doorlatende verharding (waterpasserende stenen, nokkeninfiltratie) doorgroeibare verharding (grastegels) - IT: beton en kunststof - grindkoffers - kratten, honingraad, krukjes, bollen Doorlatende verharding maaiveldprofilering Infiltratie Infiltratieriolen, Infiltratiesleuf ondergronds (percolatie) Infiltratieunits, infiltratieput/zakputten Diepinfiltratie Afvoer Afvoer direct Directe afvoer naar - gesloten, open leidingen (goten) en oppervlaktewater - (verbeterd-) gescheiden stelsel Zuiveren Filtratie Kleinschalige decentrale filters - Bladvang, buisfilter (cycloon,..) - Filterkolken, zandvangputten, Filtratie, adsorptie Adsorptie Bodempassage - zoals wadi, vaak met extra bindingsstoffen Adsorbens textielen - zeoliet, actief kool, lava, kokoskorrels humus - 3DWater Sorb-X Bezinking Centrale filters Lamellenafscheiders (ondergronds) Bezinkbakken, bezinkvijvers (bovengronds) - “ slibvangputten, olieafscheiders facet/hydrasep, 3D - betonnen bakken, damwanden, natuurvriendelijke oever SUDS Good examples are not hard to find… SUDS Learning from disfunctional SUDS How does this infiltration facility look like after x years? ? SUDS Learning from disfunctional SUDS SUDS What can be improved? SUDS evaluation: How to improve? communication Designer/planner maintenance 18 mei 20111 November 2007 14 Communication: transnational knowledge exchange by www.SKINTwater.eu innovations in Holland: Quality improvement in densed urban areas “its cheap, compact and you can drink the water that comes out of it” water sand Many new systems rapidly implemented: historical example lamellar separator Lamellenfilters:ontwerp 18 mei 20111 November 2007 “its cheap, compact 99% RO on SS and no maintenance is needed” 17 Many new systems rapidly implemented: example lamellar separator development 2000 2005 2009 time But do they work? 18 mei 20111 November 2007 19 What went wrong? Limited communication… approach: interactive research (skint) … many more innovations Do they work? Interactive research some examples: • • • • lamellar separator filtration/adsorption filter sedimentation cyclone filter Sedimentation drainage pipe Take (transparent) models to the laboratory movie Do they work? Basic measurement program Basic testing: • Hydraulics Flow (visualization) Maximum (800 l/s) • Removal efficiency Particles Oil • Extreme tests Rubbish Communication sessions Testing method: Removal efficiency fine particles solved bound to sediment Average international literature Highest study average Lowest study average Distribution pollutant stormwater runoff 100% 90% 70% 60% 50% 40% 4750-9500 90% 2000-4750 80% 850-2000 70% 425-850 60% > 63 250-425 50%m 150-250 40% 75-150 30% 63-75 30% < 63 20%m 20% 10% 18 mei 20111 November 2007 Phosphate Nitrogen Chloride PAH(10)-total Chrysene Fluoranthene Anthracene Phenanthrene Naphthalene Cadmium Pollutant Lead Zinc Copper 0% Nickel percentage [%] 80% 100% 45-63 38-45 10% 25-38 0% Koper Lood Zink Cadmium mm 24 Determination removal efficiency in detail: particle counting Flow Rate= 0,05 l/s T12 (min) 1,40E-05 1,20E-05 Inf T12 Eff T12 Volume (m3) 1,00E-05 8,00E-06 Removal efficiency 6,00E-06 4,00E-06 2,00E-06 0,00E+00 0 10 20 30 40 50 um Particle size (mm) 60 70 80 90 100 Boring graphics… Show don’t tell: Visualization of flow Movie sanddunes Movie lamellar show Communication sessions about: Show, don’t tell/ learning by doing… Discuss: 1. Cost (construction and maintenance); 2. Pressure on public space (full scale) 3. Removal efficiency; 4. Maintenance (in situ sessions); 5. Knowledge in organization putten voor zuivering regenwater: kosten Cost price SUDS in Europe (euro/m2) 5000 gem kn/m2 4000 3000 2000 1000 kostprijs systeem [euro] •How to install and maintain it 6000 kostprijs systeem M ul de rig M u ol In no en lde dr s y ai st nD R em Fi -ra lte evis i n rs io cl ch ns ea ac -F n ilt ht Fi er l lP (w r ig e i r x ol Se be in e di la ck -p bs Tr ip c e en h) m nb it au S ed w IN er is u k N bs O tra LE c T to Fi r AQ lte rp U I N ar AF N on O O e LE E L (C T R EN in Se TR ne pa IF ra O tio EL R ig ns ) io st ra -cl e ss an en Sc ab hm la uf ut zf an La ze m lle el le nk la re KM r E TU -M M al _C Hy l hb d ro C az ith on -h TU ili M ps -K i th lin op til ol ith •Understand the system kostprijs per m2 aangesloten oppervlak Show, don’t tell: 45 40 35 30 25 20 15 10 5 0 0 Several SUDS used in Europe type/product To sum it up • SUDS info available Bad examples www.skintwater.eu • New innovations introduced research before implementation! • (interactive) Research Interview stakeholders Measurement plan including communication cost-effective lab research Inspections on site/maintenance sessions Show, don’t tell/ learning by doing… Movies and detailed technical info available Thank you More info? Floris Boogaard (TU Delft/Tauw) ir. F.C. (Floris) Boogaard, (020) 606 32 50/06-51 55 68 26 e-mail: [email protected]/