THERMOMETERS - sfsi
Transcription
THERMOMETERS - sfsi
THERMOMETERS 14-4856 THERMOMETERS - CELSIUS, TEFLON ® COATED, ~; 1 0 / 3 0 , G R O U N D JOINT, YELLOW BACK, PRECISION GRADE 14-486S Similar to the 14-4855 series with the added feature of Teflon® coating to protect against shock as well as contamination in the event of accidental breakage. The entire instrument is coated with Teflon, with the exception of the ground joint. Accurate to within NIST (NBS) tolerances. Cet : : Range:: -lO'C :: ~ 75 mm Immersion 14-4856-01 14-4856-02 14-4856-03 100 mm Immersion 14-4856-04 14-4856-05 14-4856-06 125 mm Imme~ion 14-4856-07 14-4856-08 14-4856-09 150 mm Immersion 14-4856-10 14-4856-11 14-4856-12 190 mm Immersion 14-4856-13 14-4856-14 14-4856-15 215 mm Immersion 14-4856-16 14-4856-17 14-4856-18 250 mm Immerszon 14-4856-19 14-4856-20 14-4856-21 280 mm Immersion 14-4856-22 14-4856-23 14-4856-24 305 mm Immersion 14-4856-25 14-4856-26 14-4856-27 ;: (r.n THERMOMETERS - LONG IMMERSION TYPE, WITHOUT GROUND JOINT, YELLOW BACK Mercury filled, yellow backed, etched stem, available in -10 to 250°C and -10 to 360°C. Subdivisions on both ranges are 1°. Length of the 250% thermometers, exclusive of the immersion, is 11 inches; of the 360%, 12 inches. These thermometers can be used with the thermometer adapters shown under 14-6900 to 14-6950. ; i : -10 to 250°C 14-4865-22 14-4865-23 14-4865-24 14-4865-25 14-4865-26 14-4865-27 14-4865-28 14-4865-29 14-4865-30 4 5 6 7 8 g 10 11 12 41.47 43.57 45,36 47.77 48.51 50.29 51.13 55.44 56.38 -10 to 360°C 14-4866-22 14-4866-23 14-4866-24 14-4866-25 14-4866-26 14-4866-27 14-4868-28 14-4866-20 14-4866-30 4 5 5 7 8 9 10 11 12 43.57 45.04 44.70 50.92 52.71 56.17 58.90 60.16 60.16 110 150 250 45.36 48.30 52.39 110 150 250 49.14 50.40 53.13 110 150 250 50.08 58.02 55.96 110 150 250 55.96 57.22 59.43 116 150 250 59.53 61.42 64.89 110 150 250 67.72 67.72 70.56 THERMOMETERS - LOW TEMPERATURE, CELSIUS, RED LIQUID FILLED, TOTAL IMMERSION 110 150 250 71.29 53.02 74.65 Made of solid thermometer tubing having a diameter of 6 to 7 mm with expansion bulb and suspension ring. Liquid column is dyed red to facilitate reading. 110 150 250 80.22 81.58 84.21 110 150 250 86.73 87.88 90.61 Renp 14-4700-01 14-4700-02 ~ -100 to 50 -50 to 50 S U b - L e n g t h, 1 t 305 306 36.61 36.61 THERMOMETERS - CELSIUS, ~ 1 0 / 3 0 , GROUND JOINT, WHITE BACK, ORGANIC FILLED, PRECISION GRADE Similar to the 14-4855 series but with colored spirit filling in place of mercury. Ca NO. 14-4857-01 14-4857-02 14-4857-03 14-4887-04 14-4857-05 14-4857-06 14-4857-07 14-4857-08 : ; Range, % -10 -10 -10 -10 -10 -10 -10 -10 to to to to to to to to 110 150 110 150 110 150 110 150 Immersion, m 76 76 100 tO0 125 125 150 150 : Each 37.48 40.63 41.37 42.63 42.31 45.15 48.19 49.35 14-4780 THERMOMETER - LOW TEMPERATURE, CELSIUS, ORGANIC FILLED, PRECISION GRADE A total immersion thermometer filled with colored organic. Approximate length is 350 mm. Range is -200 to +30°0. graduated in 1° divisions. cat. : ~ : 14-4780-01 Low Temperature Thermometer 87.04 1155 THERMOMETERS REPLACEMENT THERMOMETERS Cat. No. 14-4852 THERMOMETERS - TOTAL IMMERSION, YELLOW BACK, RED LIQUID, ORGANIC FILLED, SAMA PRECISION GRADE Length is 305 mm. All thermometers are individually serialized. : i:: Sub, Range Each 14-4852-01 -20 to 110°C 1°C 25,09 14-4852-02 -20 to tSO°C 1% 25,09 14-4852-03 0 to 230°F 2°F 25.09 14-4852-04 0 1o 300°F 2°F 25.09 14-4852-05 35 to 50°C 1°C 08,57 14-4852-06 30 to 120°F l°F 25.00 Range,° Red Spirit Filled (For 14-4915) 14-4920-01 -30/120F 14-4920-02 +30/120F 14-4920-03 0/220F 14-4920-05 -35/50C 14-4020-06 -20/105C Mercury Filled (For 14-4916) 14-4921-01 -30/120F 14-4921-02 +30/120F 14-4921-03 0/220F 14-4921-05 -35/50C 14-4021-06 -20/105C SAFETY 25.09 25.09 25.09 27,30 25.09 25.09 25,09 25.09 14-4915 Available as red liquid filled or mercury filled. Cases are plated meta~ with pocket cJip. The metal tops in which thermometers are secured have metal rings for suspension. Length is 165 ram, with toughened bulb and permanent marking. 1156 ~ Rng~ :: Sub-~ dlv. : THERMOMETERS - SAFETY, TEFLON ® COATED, YELLOW BACK, MERCURIAL These 76 mm immersion thermometers are sealed in an inert, transparent Teflon® jacket which absorbs shock and prevents shattering. The jacket prevents contamination and also serves to retain the mercury and glass in case of breakage. Thermometers are 300 mm long. All thermometers are serialized; accurate to NIST (NBS) tolerances. Cat. No~ Range Sabdiv. Each 14-4387-01 -20 to 110% 1°C 37.22 14-4387-02 -20 to 150°C 1°C 37.22 14-4387-03 -10 to 200°C 1°C 37.22 14-4387-11 60 to 260°C 1°C 42.00 14-4387-04 0 to 230°F 2°F 37.22 14-4387-05 0 to 300°F 2°F 37.22 14-4387-06 20 to 400°F 2°F 37.22 14-4387-12 140 to 500°F 2°F 42.00 THERMOMETERS - SAFETY, TEFLON ® COATED, WHITE BACK, RED SPRIRIT FILLED THERMOMETERS - POCKET, WITH METAL CASE Ca N~ Red Spirit Filled 14-4915-01 14-4915-02 14-4915-03 14-4915-05 14-4915-06 Mercury Filled 14-4916-01 14-4916-02 14-4916-03 14-4916-05 14-4916-06 17.74 17.74 17.74 17.74 17.74 14-4387 Similar to 14-4852 but 76 mm immersion. All Celsius thermometers are in 1° divisions; all Fahrenheit thermometers are in 2 ° divisions. Length is 305 mm. -35 to 50°C -20 to 110% -20 to 150% -10 to 200°C -30 to 120°F -O to 230% 0 to 300°F 20 to 400°F 17.74 17.74 17.74 17.74 17.74 THERMOMETERS THERMOMETERS - PARTIAL IMMERSION, YELLOW BACK, RED LIQUID, ORGANIC FILLED, SAMA PRECISION GRADE 14-4853-01 14-4853-02 14-4853-03 14-4853-04 14-4853-05 14-4853-06 14-4883-07 14-4853-08 Each Each -30 to 120°F +30 to 120°F 0 to 220°F -35 to 50°C -20 to 105% 2°F l°F 2°F 1°C 1% 28.87 28,87 28.87 28.87 28.87 -30 to 120°F +30 to 120°F 0 to 220°F -35 to 50% -20 to 105°C 2°F I°F 2°F 1°C 1°C 25,41 28.87 28.87 25.41 25.41 Similar to 14-4387 except white back and red colored spirit filling. Cat; No. 14-4388-01 14-4388-02 14-4388-03 14-4388-04 14-4388-05 14-4388-06 14-4388-07 14-4388-08 14-4388-09 14-4388-10 Range. -20 to 110% -20 to 150% -10 to 2000C 0 to 230°F 0 to 300°F 20 to 400°F -50 to 50°C -100 to 50% -50 to 50°C -100 to 5g°c Subdi~ 1°C 1°C 1% 2°F 2°F 2°F t°C 1°C 1°C t°C Lenghl Immersian nun mm Each 300 76 37.22 300 76 37.22 305 75 37.22 300 76 37.22 300 76 37.22 305 76 37.22 305 76 38.95 305 76 87.85 305 Total 38.95 305 Total 57.85 THERMOMETERS DIAL-TYPE INDUSTRIAL THERMOMETERS T 14-5432 THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 2 1/2 INCH STEM Industrial grade back-connected bE-metallic 3 inch diameter dial is ideal for many applicatLons. Can be easily recalibrated with hex screw. Made o1 18-8 type 304 stainless steel with all welded construction. Stern diameter is r/4 with V2 inch NPT connection nut. Single scale in either °F or %. Actuated by super-sensitive bE-metallic helix coil. Bi-metallic element is dampened with silicone for minimum pointer vibration and maximum heat transfer. Accuracry is _+1% around the entire dial range. Dial is protected by extra heavy glass crystal Stern should be immersed at least 2 inches in liquid and 4 inches in gases. Length of stem is 2 ~/2 inches including threads, not suitable for gases. Cat, Temperatur~ NO~ : : Range,° Subtly s ons;? Each 14-5432-02 -40 to t60F 2 14-5452-03 25 to 125F 1 14-5432-04 0 to 220F 2 14-5432-06 50 to 300F 2 14-5432-07 50 to 400F 5 14-5432-08 50 to 500F 5 14-5482-09 150 to 750F tO 14-5432-10 *200 to IO00F 10 14-5432-12 0 te 50C 0.5 14-5432-15 -10 to ltOC 1 14-5482-16 0 to 150C 1 14-5482-18 0 to 300C 5 *Not recommended for continuous use above 8OO°F 68,22 68.22 68.22 68.22 68.22 68.22 68.22 68,22 68,22 68.22 68.22 68.22 Similar to 14-5432, except with 4 inch stem. Length of stem is 4 inches including threads. Stern should be immersed at least 2 inches in liquid and 4 inches in gases. : Temperaure Range,~ : : : :SubdivisionS/' 14-5483-02 -40 to 160F 2 14-5433-03 25 to t25F t 14-5433-04 0 to 220F 2 14-5433-06 50 to 300F 2 14-5433-07 50 to 400F 5 14-5453-08 50 to 500F 5 14-5433-09 150 to 750F 10 14-5438-10 *200 to 1000F 10 14-5433-12 0 to 50C 0.5 14-5483-15 -10 to ttOC 1 14-5433-16 0 to 150C 1 14-5433-18 0 te 30OC 5 *Not recommended for continuous use above 800°F Similar to 14-5432 excem wltn 6-inch stem. Length of stem is 6 riches including [nraaas. Stem should be immersed at least 2 inches in ilaUlO and 4 inches in gases. Cat. Temperature No. Range,° Subdivisions, ° Each 14-5434-02 -40 to 160F 2 63.22 14-5434-58 25 to 125F 1 68.22 14-5434-04 0 to 220F 2 68.22 14-5434-06 50 to 300F 2 68.22 14-5484-07 50 to 400F 5 68.22 14-5434-08 50 to 500F 5 68.22 14-5434-09 150 to 750F 10 68.22 14-5484-10 *200 to IO00F t0 68.22 14-5434-12 0 to 50C 0.5 68.22 14-5434-15 -10 to 110C t 68.22 14-5434-16 0 to 150C 1 68.22 14-5434-15 0 to 3000 5 63.22 Notes: * Not recommended for continuous use above 800°E K~... lh.~J THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, SACK-CONNECTED, 9 I N C H STEM Similar to 14-5432, except with 9 inch stem. Length of stem is 9 inches including threads. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. Cat, NO. 14-5435-02 14-5435-03 14-5485-04 14-5435-06 14-5435-07 14-5435-08 14-5435-09 14-5435-10 14-5435-12 14-5435-15 14-5435-16 14-5485-18 Temperature Range,Q - Each Subdivisions,° -40 to 160F 2 68.22 25 to 125F 1 68,22 0 to 200F 2 68.22 50 to 300F 2 65.22 50 to 400F 5 68.22 50 to 500F 5 68.22 150 to 750F 10 68,22 *200 to IO00F tO 58.22 0 to 50C 0.5 65.22 - 10 to tlOC 1 68.22 0 to 150C 1 68.22 0 to 300C 5 68.22 Notes: *Not recommended for continuous use above 80O°E THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 12 I N C H STEM THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 4 I N C H STEM Cat; NO THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 6 I N C H STEM Each 68.22 83.22 68.22 68.22 68.22 58.22 68.22 68.22 65.22 68.22 68.22 68.22 Similar to 14-5432 except with 12-inch stem. Length of stem is 12 inches including threads. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. Cat. N~. Temperature Range,° Subdivisions, ° Each 14-5436-02 -40 to 160F 2 75,48 14-5436-03 25 to t25F t 75.43 14-5436-04 0 to 220F 2 75.43 14-5436-06 50 to 300F 2 75.43 14-5436-07 50 to 400F 5 75.43 14-5436-00 50 to 500F 5 75.43 14-5436-09 150 to 750F tO 75.43 14-5436-10 *200 to tOOOF 10 75.43 14-5436-12 0 to 50C 0,5 75.43 14-5486-15 -tO to 110C 1 75.43 14-5436-16 0 to 156C 1 75.43 14-5436-13 0 to 3000 5 75.43 Notes: *Not recommended tor continuous use above 800°E 1157 THERMOMETERS 00 Ul DIAL-TYPE LABORATORY THERMOMETERS 14-5550 14-5555-01 14-5555-12 THERMOMETERS - LABORATORY, 1 3/4 I N C H O . D . HEAD, 8 INCH SPIKE STEM, BI-METALLIC These bi-metallic laboratory dial thermometers have a 1 3/4 inch dial and an 8 inch pointed stem. Feature sturdy stainless steel construction and super sensitive bi-metal silicone treated coil for fast response. Anti-parallax dial has large, easy-to-read numbers with raised graduations. Crystal is made of clear lexan plastic. Single scale in either °F or °C. Can be easily recalibrated with hex screw. Accuracy is 1% over the entire range. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. :Tempera~re : 14-6555-01 14-5555-82 14-5556-03 14-5555-04 14-5555-06 14-5555-06 14-5555-87 14-5555-08 14-6556-09 14-5555-10 14-5555-11 14-5555-12 14-5555-13 14-5555-14 14-5555-15 14-5555-16 14-5685-17 -100 to IOOF 25 to 125F -40 to 160F O to 18OF O to 220F O to 14OF 50 to 306F 50 to 4OOF 60 to 500F 20 to 240F 50 to 250F -50 to IOOC -10 to 110C O to 1OOC O to 150C O to 250C O to 60C 2 1 2 2 2 2 2 5 5 2 2 1 t 1 1 2 0.5 20.05 20.05 20.05 20.05 20.05 20.05 20.65 20.05 20,05 20.05 20,05 20.05 20.85 20.05 20.05 20.05 20.05 THERMOMETERS - POCKET DIAL, 1 I N C H O . D . HEAD, BI-METALLIC Bi-metallic, pocket thermometers with one inch dial and 5 inch pointed stem feature stainless steel construction. Super sensitive bi-metal silicone treated coil for fast response. Anti-parallax dial has large, easy-to-read numbers with raised graduations. Crystal is made of clear lexan plastic, Accurracy is 1% over the entire range. Supplied with a plastic carrying case, which has attached pocket clip. Case can be used as a handle. Cat. No! 14-5550-01 14-5650-02 14-5558-63 14-5550-04 14-5550-05 14-5550-06 14-5550-07 14-5550-08 14-5550-09 " TemperalJre Range,° -40 to 16OF 25 to 125F 0 to 2OOF 50 to 500F O to 156C O to 250C -40 to 70C -10 to 110C -40 to 120F Subdivisions, ~ 2 1 2 5 1 2 t t 2 Each 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 DIGITAL THERMOMETERS THERMOMETERS - LABORATORY, 2 I N C H O . D . HEAD, 8 I N C H SPIKE STEM, BI-METALLIC Similar to 14-5555 except has a 2 inch diameter dial. Can be easily calibrated with hex screw. Includes 8 inch spike stem. Accuracy is 1% over the entire range. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. : Temperaere 14-5580-01 14-5530-02 14-5530-03 14-5530-04 14-5530-05 14-5536-06 14-5530-07 14-5830-08 14-5530-09 14-5538-11 14-8830-12 14-5530-13 14-5530-14 14-8630-15 14-5530-16 1158 -100 to lOOF 25 to 125F -40 to 16OF 0 to 180F O to 220F 50 to 250F 50 to 30OF 50 to 40OF 50 to 500F 0 to 50C -50 to IOOC -10 to 110C 0 to tOOC 0 to 150C O to 250C . . . . . . 2 1 2 2 2 2 2 5 5 0.5 t 1 1 1 2 22-2967 DIGITAL POCKET THERMOMETER 28.56 28.56 26.56 26.56 28.56 28.56 28.56 28.86 28.66 28.56 28.56 28.56 28.66 28.56 Flat style digital pocket test thermometer originated as standard (not an adaptation of other models). For use where conventional bimetal pocket thermometers have been used. it will cover the range of-40 to 450°F with an accuracy of ±2°F (for -4 to 77°F) or ±4°F maximum over entire range; has a resolution of O.I°E Large 0.25 inch high oblong LC0 readout is easier to read than normal glass tbermometers. With instant update button and automatic shut-off. Features a 5 inch stainless steel stern for immersion. With red protective sheath and pocket clip. Lifetime warranty. Cat; : Na~ Des~iption |ach 28.56 22-2967-11 Digital Pocket Thermometer 29.50 THERMOMETERS UI 22-3004 22-3002 THERMOMETERS - DIGITAL, POCKET, TRACEABLE Lightweight thermometer with flat-profile design and built-in clip make it ideal to carry in shirt pocket, Operating range is from -50 to 572°F and 50 to 300°0 with resolution of 0.10 from -20 to 200°0 (1° otherwise) and accuracy of +-1.5°C.A hold button freezes a reading for later use and another button switches from °F to °C. Large, bright LCD is r/4 inch high and readings are updated every second. Operates continuously for 11/2 years on a single replaceable silver-oxide battery. Stern length is 3 r/e inches, stem diameter is 0.14 inch, overall length is 7 inches and weight is 1 ounce. Supplied with protective probe guard case and certificate traceable to NI.STstandard. 22-3004-01 Pocket Thermometer 26.82 THERMOMETERS - DIGITAL, DIAL, TRACEABLE Ideal for use in soil, cuvettes, food products and incubators. Choice of °F or °C models with wide temperature ranges of -67 to 300°F or -55 to 149°C. Resolution of 0.1 ° and accuracy -.1°. Large, bright LCD display is 3/e inch high and readings are updated every 10 seconds. Stem length is 4 3/4 inches, stem diameter is 1/8 inch and dial diameter is 1 1/2 inches in diameter, Operates for 1 V2 years on a single silver-oxide battery. Supplied with protective case, battery, and certificate traceable to NIST standard. Ca~? .... 22-3062-01 22-3002-02 : • Digital Thermometeb -67 to 3OO°F DigitalThermometer, 55 to 149°C 21.74 21.74 '\ 22-3001 THERMOMETERS - L O N G - S T E M , DIGITAL, TRACEABLE Long-stern thermometer fits into flasks, cuvettes, test tubes, and beakers. Stainless steel probe is resistant to acids, bases, solvents and most laboratory chemicals, Long stem allows user to make measurements while stirring solutions. Also suitable for reading temperature in foods, gases, samples, and semi-solids. Temperature range is -58 to 482°F and -50 to 250% with resolution of 0.1 ° from -20 to 200 ° and 1° outside of this range. Accuracy is _+0.2% between -20 and 100%. Reading are updated every second. Brilliant LCO display is V4 inch high. Stainless steel stern is 8 inches long and 1/8 inch diameter. Overall length is 11 inches. Supplied with 1 year battery and certificate traceable to NIST standard. Cat tfo. 22-3001-01 Long-Sterm Thermometer 28.15 21-2644 TEMPERATURE METER - PORTABLE, BATI'ERY OPERATED, M O D E L T M P 5 0 , C O R N I N G ~ The Model TMP50 is a microprocessor based handheld meter that accurately measures temperature in liquids, solids, and gases. Features one button operation, LCD readout, K-type thermocouple and housing, which is water and chemical resistant. Operating temperature range from -40 to 550°C with resolution of 1°C and accuracy _+2°C. Approximately 700 hours of operating battery life. Overall dimensions are 7.3 x 1 .B x 0.9 inches. Supplied with general purpose probe, battery and operating instructions. Optional probes available for air, surface, and penetration applications. cat.!: : Ce~.ni#g: : i NO :: 21-2644-02 21-2644-85 21-2644-66 21-2644-67 21-2644-08 DesCrlption: ' 475843 476452 476449 476450 476451 TemperatureMeter GeneralPurpose Probe Surface Probe Air Probe PenetrationProbe ; Each 67.58 30.45 30.45 30.45 30.45 1159 THERMOMETERS O I-m 22-3006 THERMOMETERS - DIGITAL, DIAL, JUMBO DISPLAY, TRACEABLE Smooth, stainless steel probe is resistant to acids, bases, solvents, and most laboratory chemicals. Provides continuous monitoring for over a year. Includes on/off power switch and switch to change between °F and °C. Operating temperature range is -58 to 302°F and -50 to tSO°C with resolution of O.f ° from -20 to 200 ° and 1° outside of this range. Accuracy is ±1°C between -20 and lOg°C. Extra large, bright LCD display is 0.4 inch high and readings are updated every second. Stem length is 5 r/4 inches, stem diameter is 1/8 inches, top diameter is 2 1/8 inches, overall length is 6 r/2 inches and weight is 1 ounce. Supplied with replaceable silver-oxide battery and certificate traceable to NIST standard. Cat;i : No~ ~; Description Each 22-3006-01 Junrbo Display Dial Thermometer 30.24 22-3008 THERMOMETERS - DIGITAL, FULL-SCALE, TRACEABLE Full-scale thermometer has large display, wide temperature range, stainless steel probe and long cable. Operating temperature range is -58 to 50O°F and -50 to 250°C with 0.1 ° resoJution from -20 to 200 ° and 1° otherwise. Accuracy is 1°C between -20 and tO0°C. Extralarge, bright LCD display is 0.4 inch high and readings are updated every second. Thermometer has flip-open easel stand, spring clip and magnetic back. Probe length is 5 ~rh6 inches, probe diameter is ~/8 inch, face diameter is 2 V8 inches, cable length is 10 feet and total weight is 3 ounces. Silver-oxide battery operates continuously for 1 V2 years. Supplied complete with display, probe, cable, battery and certificate traceable to NIST standard. Cat, No, Description Each 22-3008-01 Full Scale Thermometer 35.92 22-3010 22-3003 THERMOMETERS - BIG-DIGIT, DUAL DISPLAY, MINIMUM/MAXIMUM MEMORY, TRACEABLE Big-Digit Thermometer offers easy to read temperatures from across the lab. Dual displays permit reading ambient and probe temperatures simultaneously, Minimum/maximum memory reading may be displayed or reset at the touch of a button. Temperature range of ambient sensor, located inside of thermometer housing, is 23 to 122°F end -5 to 50°C. The external temperature probe with a 1g-foot cable has an operating range of -58 to 158°F and -50 to 70°C. Temperature resolution is O.t ° end accuracy is -+1°C. Minimum/maximum memory feature permits storing temperature records overnight, on weekends or for longer time periods. Unit is equipped with flip-open stand, a slot for wall mounting and a Velcro TM mounting strip. Battery runs continuously for 1 year. Housing is high-impact, chemical resistant ASS plastic with dimensions of 2 3/4 x 4 ~/4 x 3/4 inches and weight is 4 ounces. Supplied with AAA battery and certificate traceable to NIST. 22-3010-01 1160 Desctiption Big-Digit Thermometer Each 30.77 THERMOMETERS - DIGITAL, SENTRY HIGH/LOW, MEMORY, TRACEABLE The Sentry High/Low Thermometer has a triple display, which simultaneously shows high, low and current temperatures. Choice of °F or °C models with temperature ranges of -58 to 158°F or-5O to 70°C with resolution and accuracy of 1°. Sensor with 1g-foot cable may be placed under water, in a refrigerator or in a freezer. Smag ~h6 inch diameter cable allows refrigerator door to close. Simple one-button operation resets the high/low memories. Operates continuously for one year on supplied battery and includes low battery indicator. High impact ASS plastic housing with flip stand, hanging hook and magnetic back. Size is 2 5/8x 2 1/2x 3/4 inches and weight is 1.7 ounces. Supplied with battery and certificate traceable to NIST standard. Cat. No. Description Each 22-3003-01 High/Low Thermometer, °F 31.42 22-3003-02 High/Low Thermometer, °C 31.42 22-3003-11 Replacement Probe 20.32 22-3003-12 AccessoryStainless Steel Probe 59.27 THERMOMETERS 22-3009 THERMOMETERS TRACEABLE - DIGITAL, REFRIGERATOR/FREEZER, Accurately monitors temperatures in refrigerators, freezers,water baths and incubators with the enclosed "temperature buffered" sensor. Small sealed bottle filled with glycol solution holds sensor and insulates against rapid temperature changes when doors are opened. Triple display simultaneously shows high, low and current temperatures. Minimum/ maximum display monitors readings overnight, on weekends or for other periods of time. Alarm sounds when temperature rises above or falls below set points. Alarm is programmable in 1° increments. Visual and audible alarm signals continue for 12 hours even if temperature returns to non-alarm range. Operating temperature range is -58 to 158°F and -50 to 700C with resolution of 1° and accuracy of +_10C.Tenfoot microcable permits refrigerator door to close. VelcroTM and magnetic strips are provided for mounting of both thermometer and bottle sensor. High-impact, chemical resistant ABS housing is 2 3/4 x 4 V4 x 3/4 inches and weighs 4 ounces. Supplied with AA battery for one-year continuous operation and certificate traceable to NIST standard. C o t ; : H~ : :i 22-3005-01 OescrlptiOU i : : Refrigerator/Freezer Thermometer Each 36,91 22-3009 THERMOMETERS TRACEABLE - DIGITAL, HIGH/LOW 22-3009-01 22-3009-11 22-3009-12 22-3009-13 22-3009-14 22o3009-16 22-3009-17 :: 22-3007-01 DIGITAL Each High/Low Alarm Thermometer 43.99 COMPACT, Description :iech Digital Thermometer Replacement Probe Accessory Micro Probe AccessorySurface Probe AccessoryAir/Gas Probe Nylon Carrying Case AC Adapter, 120V 399.00 51.32 86.61 119.64 85.10 14.70 30.77 22-2969-01 ALARM, This thermometer is ideal for use in foods, soils, cuvettes, water baths, and incubators. Both a high and low alarm may be programmed in 1° increments. When temperature rises or falls below sot points, a 1 minute audible alarm signals an out-of-range situation. Alarm automatically resets itself when temperature returns to within set points. Alarm mode may be switched off when not required. Operating temperature range is -58 to 500.8°F and -50 to 2600Cwith resolution of 0.1° and accuracy of +_1°C.Switch from °F to °C or set high/low alarms. Digital display is 1 1/2 inches high and can be read from 10 feet. Stainless steel probe is 71/4 inches long, 1/8 inch diameter, with 3 foot cable and probe clip for handy storage. Single battery runs continuously for 1 year. Supplied with probe, AAA battery, and certificate traceable to NIST standard. cat,: PORTABLE, Ideal for routine temperature measurements in soil, foods, cuvettes, gas systems, water baths, and semi-solids. Operating temperature range is 40 to 3OO°Fand -40 to 150°C with resolution of 0.1" and accuracy of _+0.2°C. Large, bright LCD display is V2 inch high and readings are updated three times per second. Displays°F or °C at the push of a button. Membrane keys offer a splash proof design. Universal stainless steel probe is 61/4 inches long, probe diameter is ~/8 inch and cable is 5 feet. Size is 3 1/2 x 5 1/2 x 1 ~/4 inches and weight is 8 ounces. Supplied with probe, 9-volt battery and certificate traceable to NIST. 22-3007 THERMOMETERS TRACEABLE - DIGITAL, 22-2968-02 THERMOMETERS Model TM-gA is a portable lightweight thermometer with a sealed membrane touch pad. Will read in both °F and °C with an accuracy of +_0.2°For °C or ±0.2% of reading, whichever is greater (32 to 120°F). Temperature range is -40°F to +3gg°F with a resolution of 0.1°F or °C, and an accuracy of ±B.2°F from -40 to +100°F; _+0.2%from 100 to 300°E Operational status is indicated on display. Constructed of high impact resistant material making it perfect for field use. With 4 digit, 0.4 inch high backlighted LCD. Model TG-100A has the same specifications, plus is rechargeable. Includes hard carrying case, probe holder, rechargeable Nicad battery and recharger. Cat; NO~ : : : Description 22-2966-01 TC-100A Digitat Rechargeable Thermometer Portable, w/Case 22-2988-82 TM-99A Digital Thermometer Portable, w/Case Each 246.75 264.76 1161 THERMOMETERS Ilam 22-2980 DIGITAL THERMOMETER - TYPE K THERMOCOUPLE, BARNANT 22-2982 DIGITAL THERMOMETERS - TYPE J, K, OR T THERMOCOUPLE, B A R N A N T Portable, battery operated meter has a rugged housing and large ~/2 These easy-to-use meters are ideal for basic temperature monitoring inch digital display with hold function to display °F or °C. Accepts all applications. Meters are available for J, K, or T type thermocouples. type K thermocouple probes with ANSI miniconnectors. Field CAL Type K thermocouples are the most popular and offer a temperature allows user to calibrate out error factor of individual probe. range of -418 to 2501°F (-250 to 1372°C). Type J thermocouples SPECIFICATIONS: are rugged and reliable with a temperature range of -328 to t832°F Temperature Range: -50 to 1999°F (-50 to 1300°C) (-200 to IOOO"C). Type T thermocouples have the narrowest range Resolution: 0.1 from -50 to 199.9; but are ideal for low temperature applications with a range of -418 to Auto ranging to 1 above 199.9 752°F (-250 to 400°C). The four button keypad is easy to operate Accuracy: ±5% of reading or ±1°C and includes on/off, C/F for °C or °F, hold and CAL. The CAL button is whichever is greater a "capture" mode for a single (ice) point field calibration offset. Field Display: 31/2 Digit LCD, 1/2" High calibration lockout feature prevents tampering and protects factory Power: One 9V Battery (Supplied) settings. Housing is ABS/Polycarbonate impact resistant case with Battery Life: t20 Hours continous operation sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for Dimensions: 3"W x 6.5"H x I"D Shipping Weight: 2.01bs. splash and dust resistance. One year manufacturer's warranty. Supplied with battery and SPECIFICATIONS: Accuracy: -+O.9°F (-+B.5°C) above g9°; _+2°F(zl°C) instructions. Order Type K probe separately, see 22-2988, Below 99° plus _+0.2% of reading Resolution: 0.1 ° between -99.9 ° and 299.9°; 1° below 99.9° Display: 3 3/4 Digit LCD, 1/2' High 22-2980-01 6OO-OOO0 Type K Thermometer 95.00 Power: Two AA Batteries (Supplied) Battery Life: 500 Hours minimum: Low Battery Indicator Dimensions: 3.3'W x 6.2'H x f.2"D Shinning Weight: O.71bs Three year manufacturer's warranty. UL. cUL and CE certif .'c Sunnlied with naperies instructions and certificate of conformance. Order prone seoarateb, see 22-2988 Cat. Bernant No. No. gescriptla~ Each 22-2982-01 60D-1000 Type J Thermomezer 130.00 22-2982-02 600-1010 Type K Thermomezer 130 O0 22-2982-03 600-1020 Type T Thermometer 130.00 SEE OUR CHROMATOGRAPHY SELECTION Chromatography Paper, Columns, Ferrules, Injection Port Liners, Septa, Sorbents, Sprayers, TLC Plates, Tanks, Vials 1162 SEE OUR SELECTION OF SIEVE SHAKERS ATM, CSC, W.S. Tyler THERMOMETERS ........ ,) 22-2986 22-2984 DIGITAL THERMOMETERS - DUAL INPUT J-T-E-K THERMOCOUPLE, B A R N A N T DIGITAL THERMOMETER A N D DATA LOGGER DUALOGR, THERMOCOUPLE, B A R N A N T This meter accepts up to two thermocouple inputs and either J,K,T, or E thermocouples. Manually stores up to 25 readings in non-volatile memory. Features three 4-digit LCD displays and 12 button keypad for simplified set up and operation. Functions include on/ off, hold, calibration, °C/°F, J-T-E-K, maximum, minimum, differential and store. Two point field calibration feature for offset and slope. User can calibrate probe to known temperatures. Meter automatically stores and adjusts for inherent probe error enabling unparalleled system accuracy. Calibration lock out protects NIST traceable factory settings and prevents tampering with field calibration values. Housing is ABS/ polycarbonate impact resistant case with sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for splash and dust resistance. The DuaLogR is a dual input portable thermometer and data logger, which can manually store or automatically log up to 1000 sets of readings in real time. Log interval is selectable from 1 second to 60 minutes. Data can be directly downloaded to the optional infrared printer or to a computer with the optional RS232 interface adapter. Meter accepts up to two thermocouple inputs, which can be selected from the following types: J, K, T, E, R, S, N or B. Temperatures can be displayed in °F, °C, °R, or °K scales. Resolution and input filtering are selectable to improve readability during rapidly changing temperatures. Features three 4-digit LCD displays and 12 button keypad for easy operation. Capable of displaying minimum, maximum, and differential readings simultaneously using one or two probes on selectable, easy-to-read, muOi-data LCD. Two point field calibration feature for offset and slope. User can calibrate the probe to one or two known temperatures. Meter automatically stores and adjusts for inherent probe error enabling unparalleled system accuracy. Calibration feature protects NIST traceable factory settings and prevents tampering with field calibration values, Housing is ABS/polycarbonate impact resistant case with sealed silicone rubber keypad and built-in tilt stand. Rated IP54 for splash and dust resistance. SPECIFICATIONS: J: -328 to 1832% (-200 to IOOO°C) T: -418 to 752°F (-250 to 4OO°C) E: -418 to 1832°F (-250 to 1000°8) K: -418 to 2501°F (-250 te 1372°C) Accuracy: ±O.7°F (±O.4°C) above -238°F (-150°C); ±2°F (±t°C) Below -238°F (-150°C); plus ±0.1% of reading Resolution: 0.1 ° at or below 999.9°; 1° greater 999.9° Display: Three 4-Digit LCD Displays, 0.4" and 0.2" High Power: Two AA Batteries (Supplied) Battery Life: 500 Hours minimum; Low Battery Indicator Dimensions: 3.3W" x 6.2"H x 1.2"D Shipping Weight: O.71bs Three year manufacturer's warranty. UL, cUL and CE certified. SupI~lied with batteries, instructions, and certificate of conformance. Order probe separately, see 22-2988. Temperature Ranges: Cat No~ 22-2984-01 Bamant No. 600-1040 : Descrlption Dual J-T-E-K Thermometer SEE OUR SELECTION OF SYRINGE FILTERS Osmonics, Pall, Whatman : EaCh 185.00 SPECIFICATIONS: J: -328 to 1832°F (-200 to 1000°C) K: -418 to 2501°F (-250 to 1372°C) T: -418 to 752°F (-250 to 400°C) E: -418 to 1832°F (-250 to IOOO°C) R: 32 to 3241°F (0 to 1768°C) S: -418 to 2372°F (0 to 1768°C) N: -418 to 2372°F (-250 to 1300°C) B: 392 to 3272°P (200 to 18go°c) Accuracy: Type 5, K, T, E and N: +0.7°F (±0.4°C) Above -238°F (-150°C) ±2°F (-+1°C) Below -238°F (-150°C); plus ±0.1% of reading Resolution: 0.1 ° less than or equal to 999.9°; 1° greater than 999.9° Display: Three 4-Digit LCD Displays, 6.4' and 0.2' High Power Two AA Batteries (Supplied) Battery Life: 500 hours minimum, Low Battery indicator Dimensions: 3.3'W x 6.2'H x 1.2'D2 Shipping Weigh1 0.71bs. Three ~ear manufacturer's warranty. UL, cUL and CE certified. Supsued wlm oatrenes, instructions, and certificate of conformance. Oraer erode seoaretw, see 22-2988. Temperature Ranges: Cat, No. 22-2986-01 Barnnt No. Descriplien 600-1050 Thermometer/Data Logger Eech 240.00 1163 THERMOMETERS . . . . . . . . . . . . . . . . . - - - • .... i t • 22-2988-01 i = . ....... ¸ 22-2988-11 22-2988-41 THERMOCOUPLE PROBES - INTERGRAL HANDLE, BARNANT Thermocouple Probes for use with Barnant Digital Thermometers and DualLogR thermometer/data logger. Can also be used with any thermocouple thermometer that accepts miniconnectors. Supplied with 5-foot coiled cables with PVC/PVCinsulation and miniconnectors. Cable are ANSI color coded for easy identification: Type J cables are black, Type K are yellow, Type T are blue, and Type E are purple. Intergral probe handle is 5 1/e inches long glass-filled nylon. Choice of probes includes: general purpose, Teflon® coated general purpose, air/gas, surface and penetration. General Purpose Probes 22-2988-01 601-1000 22-2988-02 601-0000 22-2988-03 601-2000 22-2988-04 601-3000 Teflon® Coated General Purpose Probes 22-2988.11 685-1757 22-2988-12 685-1657 22-2998-13 685-0057 22-2988-14 685-1257 Air/Gas Probes 22-2988-21 604-1000 22-2988-22 604-0000 22-2988-23 604-2000 22-2988-24 604-3000 Surface Probes 22-2988-31 602-1000 22-2988-32 602-0000 22-2988-33 602-2000 22-2988-34 602-3000 Penetration Probes 22-2988-41 603-1000 22-2988-42 603-0000 22-2988-43 603-2000 22-2988-44 603-3000 Maximum : Temperature Prabe Length,in Each J K T E 1400°F (760°C) 1652°F (900%) 550 °F (288°C) 1600°F (871°C) 4 15/16 4 15/16 4 15/16 4 15146 36.75 36.75 40.95 42.00 J K T E 302°F 302°F 302°F 302 °F (150%) (150°C) (150°C) (150°C) 10 1O 10 10 57.75 57.75 57.75 59.85 J K T E 572"F 572 °F 572°F 572°F (300°C) (30O°C) (3go°c) (3OO°C) 8 1/e 8 1/e 81/8 8 1/8 48,30 48.30 48.30 58.80 J K T E 1200°F (649°6) 1200°F (649°C) 650 °F (343°C) 1200°F (649°C) 9 15/16 9 15/16 915/~e 915he 55.05 56.65 55.65 68.25 J K T E t4OO°F (760%) 1652°F (9OO°C) 550°F (288%) 1600% (871°C) 4 4 4 4 39.90 39.90 39.90 44.10 / 22-2986, 22-2987 21-2649 ACCESSORIES - FOR 22-2986, DUALOGR, THERMOMETER AND DATA LOGGER, BARNANT TEMPERATURE METER - PORTABLE, BATTERY OPERATED, MODEL 309, CORNINGo Accessories for DuaLogR thermometer and Data Logger. The infrared printer is ideal for on-site documentation. Data is transferred by infrared output, no cable to connect, just line up data transmission LED located on top of instrument and position printer within 18 inches. Print readings in real time from every three seconds to every 60 seconds or automatically print previously stored data. Printer supplied with one roll of paper. Optional printer power adapter 110-240V, 50-6gHz with 6-foot power cord. RS232 interface adapter connects data logger to computer with 9-pin serial port for easy downloading of data. Does not include software. Optional power adapter 115VAC for for DualLogR. The Model 309 is a microprocessor based temperature measurement system that uses a thermistor type of temperature input probe. This portable, handheld unit accurately measures temperature in liquids, solids, and gases. Features include push button operation, LCD readout, temperature display in °C or °E HI/LO recall, low battery indicator, and auto off. Operating temperature range from -50 to 150°C with resolution of 0.1°C and accuracy of ± 0.4°C. Approximately lOg hours of operating battery life. Splash-proof housing with easy to use membrane keypad. Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general purpose probe, wrist strap, battery and operating instructions. Optional probes available for air and penetration applications. Cal. Coming Ne~ : No. Descrlptian Each 21-2649-02 475852 Temperature Meter 155.40 21-2649-05 476604 GeneralPurpose Probe 60.90 21-2649-07 476605 Air Probe 76.65 21-2649-08 476606 Penetration Probe 60,90 22-2987-01 22-2987-02 22-2987-08 22-2987-04 22-2987-00 1164 600-0080 600-0082 37455-71 600-0090 600-0070 Infrared Printer 235.08 PrinterAdapte5 100-240VAC 65.00 PrinterPapeE Pkg. of 6 Rolls 12.00 RS232 Inte~ace Adapter 95.00 DuaLogRAdapter, t15VAC 31.00 THERMOMETERS ..-= Ut 21-2650 TEMPERATURE METER - PORTABLE, BAI"rERY OPERATED, MODEL 3 1 0 , C O R N I N G ® The Model 310 is a microprocessor based temperature measurement system that usesa K- typethermocouple with detachableprobe handle.This portable, handhetdmeter is ideal for a wide rangeof temperature measurement applications. Features include push button operation, LCD readout, temperature display in °C or oF,HI/LOrecall, tow battery indicator, and auto off. Operatingtemperature rangefrom -50 to 950°C with resolution of 0.1°C (-50 to 150) and 1°C (>150). Temperatureaccuracy is _+0.5°C or _+0.5% (-50 to 150) and ± 1.0°C or _+0•5% (>150). Approximately100 hours of operating batterylife. Splash-proof housing with easyto use keypad. Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general purpose probe, wrist strap, battery and operating instructions. Optional probes availablefor air, surface and penetrationapplications. Cat; : N0~ Carn!0it " : N0 21-2650-02 21-2650-05 21-2650-06 21-2550-07 21-2650-08 21-2650-09 475853 476607 476610 476608 476609 470441 i : : : Descrlpt it~ :.!: TemperatureMeter General Purpose Probe Surface Probe Air Probe PenetrationProbe Probe Handle i : Each 263.12 30.57 30.45 80.45 30.45 40.05 22-3035 HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M / M A X I M U M M E M O R Y , TRACEABLE Ideal for monitoring around-the-clock and for routine measurements of relative humidity and temperature. Suitable for quality control applications. Continuously and simultaneously displays relative humidity and temperature in °E or °C with dual-recall memories. Minimum and maximum memories may be displayed or cleared at any time with the touch of a button. Environmental conditions can be monitored overnight, on weekends, or for longer time periods. Temperature range is 32° to t 22°F and 0° to 50°C with resolution and accuracy of 1° . Humidity range is from 25 to 95% with resolution of 1%RH and accuracy of _+2% in mid-range to _+4% at the extreme ends of range. East-response solid-state sensor displays changes in less than 30 seconds. Large, easy-to-view 5/8 inch high digits are updated once every second• Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and humidity in labs. Case is shock and chemical-resistant ABS plastic. Size is 2 5/e x 3 7/8x 3/e inches and weight is 2 1/2ounces. Supplied with wall mount, bench stand, solid-state sensors, switch to read °F/°C, two AAA batteries and certificate traceable to NIST. Choice of three models available. Catalog number 22-3035-01 offers digital humidity/temperature with dual minimum/maximum memories. Model 22-303502 offers digital humidity with minimum/maximum memory but without temperature. Catalog number 22-3035-03 offers digital humidity/temperature but without memories• Cat; NOi ~ . . . . . PEN - DIGITAL, Pocket pen with clip is easyto carry and is idealfor measuring humidify and temperature levels. Pen continuously and simultaneously displays both RH and °F or °C with dual-racall memories. Memory displays highest ano lowest humidity/temperatura readings observed overnight or during any time period. Easy-to-read LCD display is 1 1/2 inches high and is upoatea once every second. Pocket pen has fast-response solid-state sensors. which respondto changes in less than 30 seconds. Temperature range ~s 32° to 122°E and 0° to 59% with resolution of 0.1° and accuracy of +_1°C. Relative humidity range is 2 to 98% with resolution of 1% and accuracy of _+2%at mid-range to 4% at ends of range. Supplied with two s [ver-oxloe batteriesfor 6 month of continuous operation. Caseis high-impact, chemical resistantABS plasticwith dimensions of 5 Vex 1 x 7/8inches and weight of 1 1/2 ounces. Supplied with batteries and certificate traceable to NIST Cat. NO. " . 22-3037-01 " Descdptlon : 22-3036-01 Hygrometer/Thermometer, Min/Max Memory 22-3035-02 HygrometerOnly with Min/Max Memory 22-3035-03 Hygrometer/Thermometer without Memory 22-3037 HYGROMETER/THERMOMETER M E M O R Y , TRACEABLE i Des¢rlp0ee Each Hygrometer/Thermometer Pen 48.23 ]Each 60.59 51.67 57.77 SEE OUR SELECTION OF FILTER APPARATUS Nalge Nunc, Osmonics, Pall, Whatman 1165 THERMOMETERS 22-3036 HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M / M A X I M U M MEMORY, TRACEABLE Continuously and simultaneously displays relative humidity and temperature in °F or °C with dual-recall memories. Minimum and maximum memories may be displayedor clearedat any time with the touch of a button. Conditions can be monitored overnight, on weekend or for longer time periods. Contains ambient relativehumidity and temperaturesensors within case and externaltemperature sensor with lO-foot cable. Externaltemperature probe rangeis-58 to 158°Fand -50 to 70°C.Ambient sensorrangeis 23 to 122°Fand -5 to 50°C. Temperatureresolution is t ° and accuracyis _+1°C. Humidity rangeis 25 to 95% with resolution of 1% BA and accuracyof ±2% in the mid-range to ~ % outside of mid-range. Fast response solid-state sensors show display changes in lessthan 30 seconds. Large,easy-to-view 1 ~/8 inch high digits are updatedonce even/second. Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and humidity. Caseis shockand chemical-resistant. Sizeis 3 7/8x 4 r/4 x3/4inches and weight is 5.4 ounces. Supplied with flip-open stand, wall mount, AAA batteryand certificatetraceableto NIST 22-3036-01 Digital Hygrometer/Thermometer |.oh 56.50 22-3039 HYGROMETER/THERMOMETER - DIGITAL, TRACEABLE ideal for constantly monitoring labs, fume hoods, plant areas and storage facilities. Provides humidity and temperature readings instantly. Humidity range is 25 to 95%BH with resolution of 1% and accuracy of _+2%RH at mid-range to _+4% at ends of range. Temperature range is 32° to 122°F and 0° to 50°C with resolution of 0.1 ° and accuracy of ±1 °C. Large, easy-to-read LCD has V2 inch high digits. Modern design is housed in a rugged ABS plastic case with dimensions of 3 ~/2 x 5 x 7/8 inches and weighs 6 ounces. Single AA battery provides I 1/2 years of continuous operation. Supplied complete with screw for wall mounting, plastic stand for bench use, battery and certificate traceable to NIST. Cal. No, Description Each 22-3039-01 Digital Hygrometer/Thermometer 48.03 RECORDING THERMOMETERS WEATHER H A W K RECORDING THERMOMETER 22-3038 HYGROMETER/THERMOMETER - DIGITAL, MEMORY, TRACEABLE Unit constantlymonitorstemperature and humiditywith memorycapabilityto recall high and low readings. The instrument is always on, as there is no off switch, and makes continuous readings.Equippedwith an ambient humidity/ temperature sensor inside of the housing and an externaltsmperatureprobe with a 10 foot cable. Displaysimultaneouslyshows probetemperature,ambient temperature and ambient humidity Minimum anD maximum memory readingsmay be recalledor clearedwith the rouce of a button. Humioayrange is 25 to 95% RH with resolution of 1% and accuracyof _+2%at mid-rangeto -+4°/°at ends of range, ambient temperature range is 32" to 122°Fand O" to 50°C. ExtemaJtemperature sensor range is -58° to 158°Fand -50° to 70°C Temperature resolution is 0.1° and accurac~ is _+1"0.Bright LCD Digits are V2 inch high. Case is high-impact, Chemical resls~am ABS nlastic with dimensions of 3 V2 x 5 x 7/8inches and weight is 6 ounces.Two AA eanenes provide one year of continuous operation. Suoolled comolete with ulastlc stand, internal humidity/temperature sensor, and external zemeerature sensor with 10 foot cable, AA batteriesand certificatetraceableto N S]~ 22-0038-01 1166 Digital Hygrometer/Thermomezer 56.43 Provides a continuous record of temperature variations over a 7 day period. Accuracy is ±I°E It can be used outdoors or in the laboratory area, for example, in environmental cabinets. Dimensions are 13 x 7 x 7 inches high. The electrically driven drum revolves one complete turn in seven days. The chart, in 2° divisions, ranges from -40 ° to 120°F and has colored bands which clearly indicate the significant temperature zones for convenient reading. Complete with 40 foot capillary tubing, 3-wire cord and plug, 52 charts, ink and instructions. For operation on 110 volts, 60 Hz, AC. (:at. No. Description Each 22-2995-01 Weather Hawk Thermometer 600.00 SEE OUR SELECTION OF FUME HOODS Captair, Kewaunee, Labconco THERMOMETERS ",4 22-3080 THERMOMETERS - R E C O R D I N G , P E R M A N E N T D R Y STYLUS, PTC 22-3050 THERMOMETERS BACHARACH - R E C O R D I N G , TEMPSCRIBE, These recording thermometers have a wide range of laboratory applications such as continuous recording of temperatures in heated or refrigerated incubators, controlled temperature rooms, fermentation cabinets or similar compartments. They can also be used for meteorological recordings if suitably protected from rain, snow and direct sunlight. Each instrument consists of a hi-metallic coil which has a thermal responsiveness of 0.5°F, recording pen and chart which is turned by a sturdy spring-wound clock, all mounted in a strong plastic case which can be flush mounted, suspended or set on a level surface. Temperature chart is 4 1/2 inches in diameter. Each unit is suppiied complete with two marker pens and 100 charts. Ca No. : Temperature range onecharf Temp. ~rn dv. Time dv. : :Each 22-3050-01 22-3050-02 22-3050-05 22-3050-06 22-3050-09 22-3050-11 -30 to 120°F 7 days 5°F 3 hr, -30 to 120°F 24 hr. 5°F 15 min 40 to 10O°F 7 days 2°F 3 hn 40 to t00°F 24 hr 2°F 15 min -tO to 50°F 7 days 2% 3 hr 30 to 50°0 7 days 2°C 3 hr. RECORDER CHARTS-FOR 22-3050 Catalog suffix numbers correspond with those of the Recorders, e.g., 22-3051-01 is for 22-3050-01. Cot :N~!!i ~' i~i:~:~il ~ ~i~ : :i; ! ~ 390.02 390.02 390.02 390.02 390,02 390.02 22-3050 Pkg Qiy~Price! ~,: 22-3051-01 22-3051-02 22-3051-55 22-3051-06 22-3051-09 22-3051-11 100 100 105 100 100 100 -27.00 -27.00 - 27.00 - 27.00 - 27.00 -27.00 M A R K E R PENS - F O R TEMPSCRIBE R E C O R D I N G THERMOMETERS Two marker pens in two-compartment Mylar packet for use with 223050 Recording Thermometers. For use at -30 to +150°F; 0-100% humidity. Provide 6 months to one year continuous use. Cat; :: : N~ COoi": 22-3064-02 Red Pko : : Qty--Price i 2- 22.83 Portable unit records temperatures permanently over periods of up to 24 hours or up to 7 days, Accuracy is _+2%of full scale range. Can withstand rugged environment and rough handling. Ideal for use in refrigerators, coldrooms, dairies, drying sheds, greenhouses as well as in schools, hospitals, and offices. For wet environments or extremely high humidity, the unit can be placed in a heavy polyethylene bag or sealed container, Clock movement is spring wound. A permanent, sharp stainless steel stylus presses against a plastic coated 3 5/8 inch circular chart leaving a distinct black line against the white paper and blue temperature and time graduations. NIST certification available upon request. 100 charts are provided. Cat~ -: HO~! = Range°F/°C Tlmerahge = 22-3080-01 22-3080-02 22-3080-03 22-3080-04 22-3080-05 22-3080-06 22-3080-07 22-3050-08 22-3580-09 22-3080-10 22-3080-11 22-3080-12 22-3080-13 22-3080-14 -40 to 160°F 24 hrs. 40 to 160°F 7 days 0 to 10O°F 24 hrs. 0 to 1OO°F 7 days 20 to 220°F 24 hrs, 20 to 220°F 7 days -5 to 50°C 7 days -5 to 105% 24 hrs. -5 to 105°C 7 days -5 to 5O°C 24 hrs. 20 to t20°F 24 hrs. 20 to 120°F 7 days -30 to 7O°F 24 hrs. -30 to 70°F 7 days, 22-3080-15 -40 to 70% 24 hrs. 22-3080-16 -40 to 70°C 7 days RECORDER CHARTS-FOR 22-3080 Catalog suffix numbers correspond with those of Recorders, e.g., 22-3083-01 is for 22-3080-01. Car.; NQ~ : ~ 22-3083-01 22-3083-82 22-3083-03 22-3083-04 22-8883-05 22-3083-06 22-3083-07 22-3883-08 22-3083-09 22-3083-10 22-3083-11 22-3083-12 22-3083-13 22-3083-14 22-3083-15 22-3083-16 MOUNTING Each 504.00 504.00 504.00 504.00 504.00 504,00 504.00 504.00 504.00 504.00 504.00 504.00 504.05 504.00 504.00 504,00 22-3080 9kg Qty-Pdce 100 100 100 100 100 180 180 100 100 100 100 100 100 100 100 100 -13.50 -13.50 -13.50 - 13.50 -13.50 - 13.55 -13.50 - 13.50 -13.50 - 13.50 - 13.50 - 13.50 -18.50 - 13.50 -13.50 - 13.50 BRACKET - STAINLESS STEEL Cet, i . 22-3081-01 Description " Each Mounting Bracket 32.81 1167 THERMOMETERS -,% cO 22-3365 RELAY CONTROL - SOLID STATE, MECHANICAL, P R I N C O T688 22-3230 THERMOREGULATOR - FULL RANGE TYPE, M A G N A - S E T ~, P R I N C O Fully adjustable, rapid setting thermoregulator with an accuracy to 0.002°0. Exclusive Pdnco Magna-Set principle brings accuracy and sensitivity formerly unavailable in adjustable temperature controls. Unique design features include a variable electrode with a magnetically controlled micrometer adjustment which permits changes of 0.005°C in operating temperature and improved mercury trap (or reservoir) used in making the preliminary, rough adjustment. Controls a well agitated constant temperature bath of good design to within 0.01°C Under ideal conditions a variation as little as 0.002°C has been maintained. Overall length is 335 mm including a two-piece detachable connector and cord. Diameter of ooey iS 14 ram, A suoer sensitive relay (22-3362-11 Js recommenaea: maximum capacity is 3 milliamperes at 110 volts 60 Hz. AC. -~" 22-3230-11 DescriFtion Thermoregulazor Each 420.00 For use with laboratory thermoregulators and thermostats. Unit combines solid state and mechanical components to obtain the advantages of both. There are two input binding posts, two AC receptacles and a load indicating pilot light. A one second time delay prevents chattering. This relay controls a resistive load up to 1000 watts. It operates on 115 volts, AC and provides an activating current of 100 microamperes at 7 volts DC. Complete with a heavy-duty line cord and plug. Case measures 4 x 4 x 2 inches. Cat. No. Description 22-3365-01 Relay Control SEE OUR GLOVE SELECTION Disposable Gloves, Reusable Gloves, Chemical Resistant Gloves, Temperature Resistant Gloves 22-3362 RELAY CONTROL - SOLID STATE, PRINCO T681SS A heavy duty solid state controller for use with laoorazory mermoregulators, especially the 22-3230-1t. Controls cads frorr 25 to 1500 watts. "Percent Power" ala regulates power from O zo 100%. Provides signal current of only 6 microamoeres to tl~e thermoregulator. With twin pilot lights, controlled Ioaa aria convemence outlets and heavy duty 3-prong plug. Case measures 7 x 6 x 4 inches Ii~gh. For operation on 115 volts. AC 22-3362-11 1168 Relay Control Each 630.00 SEE OUR BALANCE SELECTION A & D Weighing, Acculab, Ohaus, Sartorius, Thermo Cahn, Troemner Each 288.75 THERMOMETERS SPECIAL-USE THERMOMETERS ...a ...a 14-5000 THERMOMETERS - "EXACT-TEMPE" ERTCO Consists of an NIST traceable, Teflon®-coated thermometer in an unbreakable plastic bottle filled with propylene glycol, ethylene glycol or vermiculite. Each thermometer has an individual serial number and has been listed against a standard calibrated at the National Institute of Standards and Technology (NIST). A certificate of accuracy is supplied with each thermometer, Velcro is affixed to each bottle permitting the thermometer to be attached to the wall or door of the instrument, reducing space and breakage problems. All thermometers are total immersion. cat Range, Length, Div., Type ~ Liquid Each No. : nslremeet : C ran. C 14-5000-01 14-6000-02 14-5000-03 14-5000-04 14-5000-05 14-5000-08 14-6000-07 14-6000-08 14-5000-09 14-500G-10 14-5000-11 14-6000-12 Ultra-low Freezer Freezer Blood Bank Refrigerator Incubator Oven Oven Freezer Refrigerator Incubator Oven Oven -90 to 20 -30 to 0 -5 to 20 -5 to 15 -18 to 50 20 to 130 35 to 200 -30 to O -5 to t5 18 to 50 20 to 130 35 to 200' 145 125 125 125 135 135 145 1 O0 125 1 go 135 145 1.0 0.5 0.5 0.5 0.5 1.0 1.0 1 .O 0.5 1 .O 1.0 1.0 Spirit Spirit Spirit Spirit Spirit Spirit Spirit Mercury Mercury Mercury Mercury Mercury PP Glycol PP Glycol Eth. Glycol Eth. Glycol Eth. Glycol Vermiculite Vermiculite PP Glycol PP Glycol Eth. Glycol Vermiculite Vermiculite 58.48 46.41 70.14 46.41 46.41 48.41 78.01 46.41 46.41 46.41 46.41 78.01 SEE OUR SELECTION OF TUBING Fluoropolymer, Latex, Norprene, Polyethylene, Polyvinyl Chloride, Polyurethane, Pure Gum Rubber, Silicone, Teflon, Tygon SEE OUR SELECTION OF PIPETTORS BD Medical, BrandTech, Eppendorf, Finnpipette, Jencons, LabBest, Oxford, Popper, Volac 1169 THERMOMETERS ~(~ 14-5930 THERt~4OMETERS - PRECISION., FOR SPECIAL APPLICATIONS, ERTCO All thermometers are serialized for the purpose of traceability and all are accurate to within NIST (NBS) tolerances. rv~ IC 1.0 1.0 1.0 10 0.5 0.5 1.0 1.0 0.1 0.1 0.5 05 1.0 1.0 1.0 1O 1.0 1.0 0.5 0.5 1.0 10 1O 1.0 1O 1.0 1.0 10 t0 1O 1.0 1.0 2.0 20 tO 10 05 SFeda :fea!utes* 1, 2 1, 2 Applkatlons incubator, Water Bath Incubator, Water Beth Incubator, Water Bath Incubator, Water Bath Incubator, Water 6aths Incubator, Water Bath Incubator, Water Bath Incubator, Water Beth Coliform Incubator Coliform Incubator Block Heater, Water Bath Block Heater, Water Bath Block Heater, Water Bath Block Heater, Water Beth Short Immersion Bath Short Immersion Bath Blood Bank, Refrigerator Blood Bank, Refrigerator Incubator, Water Bath Incubator, Water Beth Autoclave, Max. Reg Autoclave, Max. Reg Ovens, Oil Baths Ovens, Oil Baths Ovens Ovens Ovens Ovens, Oil Baths Ovens, Oil Baths Ovens, Oil Baths Ovens, Oil Bathe Ovens Vacuum Ovens Vecuum Ovens Vecuam Ovens Vacuum Ovens Enzymology 14-5930-03 20 to 100 305 76 14-5930-13 20 to 100 305 76 14-5969-64 0 to 60 250 1 O0 14-5030-14 0 to 80 250 100 14-5930-01 0 to 50 305 150 i 14-5930-11 0 to 50 305 150 1 14-5930-02 O to 70 330 150 1 14-5930-12 6 to 70 330 150 1 14-5930-05 34.5 to 46 237 76 2 14-5930-15 34.5 to 46 237 76 2 14-5929-01 25 to 57 175 35 2 14-5929-11 25 to 57 175 35 2 14-5929-02 0 to 100 225 35 14-5929-12 0 to 100 225 35 14-5928-01 O to 50 1 O0 12 14-5928-11 0 to 50 1 O0 12 14-5927-01 -5 to 20 t 52 Total 2 14-5927-11 -5 to 20 152 Total 2 14-5930-06 25-37-56 240 76 2 14-5930-16 25-37-56 240 76 2 14-5930-07 80 to 135 200 Total 14-5930-17 80 to 135 200 Total 14-5925-01 O to 300 405 125 i 14-5925-02 O to 300 455 150 1 14-5925-03 0 to 300 610 305 1 14-5925-04 0 to 200 610 305 1 14-5925-14 0 to 200 610 305 1 14-6925-05 0 to 200 280 76 1 14-5925-15 0 to 200 280 76 1 14-5925-06 0 to 200 405 125 1 14-5925-16 0 to 200 405 125 1 14-5925-07 0 to 350 455 150 1 14-5926-01 24 to 130 135 Total 14-5926-11 24 to 130 135 Total 14-5926-02 35 to 200 180 Total 14-6926-12 35 to 209 180 Total 14-5032-01 24 to 38 300 95 *Special Features: 1. Immersion enlargement on thermometer stem 2. Arrows on scale indicating critical temperature SEE OUR SELECTION OF BRUSHES Assay, Beaker, Bottle, Buret, Camel Hair, Carboy, Centrifuge Tube, Cylinder, Flask, Graduate, [mhoff Cone, Pipet, Static Master, Test Tube 1170 Teflo.® coaled No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yea No Yes No Yes No No No No Yes No Yes No Yes No No Yes No Yes No Each 44.73 52.60 32.65 40.53 31.81 39.58 39.06 46.83 68.04 75.81 43.36 51.13 42.94 50.71 42.94 50.71 25.51 33.28 33.07 40.95 52.50 60.99 38.95 46.30 62.05 62,05 69.82 38.32 38.32 42.90 49,77 62.65 35.91 43.68 36.75 44,52 74.76 THERMOMETERS THERMOMETERS - ASPHALT TESTING, THERMOMETER ONLY C=ti NO, 14-5399-01 14-5399-02 Range,°F : |=ch 50-450 50-600 50,77 26.26 d THERMOMETERS - CLINICAL, ASEPTO ®, B'D T M Accurate and dependable fever thermometer with easy-to-read blue scale. Reads in Fahrenheit. Supplied in white plastic case with Lok-ln feature. Cat; : Pkg No, ~ 9-DTMNo. Typebulb Qly- price 14-5885 THERMOMETERS - AIR I M M E R S I O N , CLEAN R O O M , PTC ® These instruments are engineered to accurately measure ambient air temperature within +_2% of full scale range. Ideally suited for temperature-controlled clean rooms, cold rooms, laboratories and large areas or volumes used in environmental testing, Three temperature ranges are available: -20°F to +160°E O°F to 250°F and O°F to 50O°E Dimensions: 2 inch diameter x height, 1 inch. An ancillary hand is available for this instrument. It is held by a magnetic clutch and will retain a maximum or minimum reading. One year warranty. NIST certification available upon request. Cal~ No, 14-5885-01 14-5885-02 14-5885-03 lu~ II Range,~: °F . . . . . . . -20 to 160% 0 to 250°F 0 to 500°F Subdlv. 2° 2° 5° With Ancillary Hand 14-5885-04 -20 te 160°F 14-5885-05 0 to 250°F 14-5885-06 0 to 500°F 2° 2° 5° ..... Each 68.25 68.25 68.25 14-4795-01 14-4795-02 524015 524025 Oral Rectal 66- 29.42 29.42 14-5935 THERMOMETERS - D E W P O I N T Totalimmersion thermometers with an overalllength of 255mm. Cat.! Noi 14-5935-91 14-5935-02 ana Re, -30 to 110 -90 to 40 Sub~ : dlv; Each 1° 1° 30.66 51.34 87.93 87.93 87.93 THERMOMETERS - ASPHALT TESTING Supplied with penetration nickel plated brass armor case. Overall length 11 inches; 5 ° divisions. Cat; Noi 14-5398-01 14-5398-02 : Thermometer Only 14-5399-01 14-5399-02 Renge~°F 50 - 450 50 - 600 Each 56.38 56.38 50 - 450 50 - 600 50.77 26.26 THERMOMETERS - ASPHALT TESTING, POCKET TYPE 100 - 450°F with epoxy coated bulb for penetration protection; 5 divisions. Complete with aluminum protective case. No. 14-5406-01 14-5400-02 Range~ F ~~ Thermometer w/Case Refil~ Only Each 44.52 35.70 14-5780 THERMOMETER - DOUBLE SCALE, I N D O O R , COMFORT METER TM, TAYLOR With permacolor tube and magnifying lens. Wood grained frame finish. Bold white numbers and graduations on a brown background. Ranges are -60 to 130°F and -50 to 55°C. Overall dimensions are 7 5/8x 2 1/4 inches. Ce|. : No; : 14-5780-01 ~ Description Double Scale Thermometer ~ Each 11.95 1171 THERMOMETERS C'q r~ 14-5850 THERMOMETERS - M A X I M U M REGISTERING, MERCURIAL, W I T H PROTECTIVE CASE 14-5840 THERMOMETER - M A X I M U M REGISTERING, TAYLOR AND MINIMUM, SELF Complete with setting magnet and improved tube fastening. With a range from 40 to 130°F in two degree divisions. High temperature is registered at top of one side and low at top of other side. Mercury filled. Dimensions are 10 V2x 2 3/sx 1 ~/4 inches. o~ : 14-5840-01 : Thermometer : Each 23.49 For general testing in applications where it is impractical to make an immediate reading. The mercury column will not recede until shaken down or reset similar to fever thermometers. Overall length is 61/2 inches. Available in fully enclosed pocket case or in open-faced armor case. Cases are anodized aluminum and provided with pocket clip. Cat. Scale SubNoi ra~e dlv. Each Complete 14-6850-11 14-6950-12 14-5650-13 14-5650-15 cat. N0. O to 220°F 50 to 3OO°F 50 to 40O°F -20 to 150°C 2° 2° 2° 1° renge Replacement Thermometer-for 14-5850 14-5855-11 O to 220°F 14-5855-12 50 to 300°F 14-5655-13 50 to 400°C 14-5359-15 -20 to 150°C 45.36 45.36 45.36 45.36 Each 37.60 37.90 37.90 37.90 14-5842 THERMOMETER - M A X I M U M REGISTERING, DUAL SCALE AND MINIMUM, SELF Ranges are -40 to 5O°C in 1° divisions; -40 to 120°F in 2° divisions. Mercury filled. Reset with the press of a button. 14-4975 14-5842-01 Thermometer MICROCHEMISTRY KITS SEE Corning, Wheaton 12-9960 TO 12-9965 ]172 75.00 THERMOMETERS - MERCURIAL, FLOATING DAIRY, FAHRENHEIT Has a transparent coating for protection against shattering on sides of vat. The coating does not interfere with reading, and in case of breakage prevents contamination by mercury and glass fragments; is not affected by action of hot milk and will have no effect on the taste or quality of the milk• Diameter is 15 mm; length is 270 mm. Cat, Range, SubNe. °F dlv.,° Eeck 14-4975-Ol 20 to 160 2 32.76 14-4975-02 20 to 220 2 34.02 THERMOMETERS Q 14-5880 THERMOMETERS - SURFACE TEMPERATURE, DUAL MAGNET, GLASS COVER, PTC ® 14-5900 THERMOMETERS - SPOT CHECK, 1 a/4 INCH DIAL, PTC~ Employs a bimetallic coil sensor which has direct contact with the surface to be measured. In response to temperature, the sensor expands or contracts causing the 1 3/4 inch dial itself to rotate. This thermometer reads temperatures of all flat surfaces such as dies, hot plates, heavy sheet metal, etc. It also reads ambient temperatures in enclosed spaces, as well as in noncorrosive liquids and gases, up to 1000°E Accuracy is _+2% of full scale. NIST certification available upon request. Cat; No. : Range, F/°C " i , 14-5900-01 14-5900-02 14-5900-03 14-5g00-04 14-5900-05 14-5900-06 14-5900-07 O to 270°F 50 to 320°F 50 to 5OO°F 50 to 1000% 10 to 160°C 10 to 260% O to 525°C S..b, : dlv. Each 2° 2° 5° 10 ° 1° 2° 5° 36.75 36.75 36.75 21.00 36.75 36.75 21.00 Designedto be used on hodzontalor ferrous non-horizontalsurfaces. Dimetallic sensor is locatedin a draft shieldand is in virtual thermal contactwith surface to be measuredgivinga relativelyquickresponsetime. Glasscovered dual magnetsurface thermometeroperates across a total rangefrom -100 to +750°Fand-70 to +400°Cwith an accuracyof ±2%. Diameteris 2 inches. Two Alnico magnetshold it securely in placeon horizontalor non-horizontal steel or ferrous metalsurfaces. NISTcertificationavailableupon request. CaI~ Na~ : 14-5880-01 14-5880-02 14-5880-03 14-5880-04 14-5880-05 14-5880-06 14-5880-07 14-5080-08 14-5880-09 14-5880-10 Range, "F/°C Subdlv, Each -100 to 160°F 0 to 150°F O to 250°F 0 to 5OO°F 50 to 750°F -70 to 70°C -15 to 65% -20 to 120°C -20 to 250°C 10 to 400% 2° 1° 2° 5° 10 ° 2° 1° 1° 2° 5° 52.44 52.44 52.44 52.44 29.95 52.44 52.44 52.44 52.44 29.95 THERMOMETERS - SPOT CHECK, I 3/4 INCH DIAL, N O N - H O R I Z O N T A L SURFACES, PTC ® Similar to 14-5900 but includes magnet and leaf spring for use on non-horizontal ferrous surfaces or for permanent mounting. NIST certification available upon request. Car : ~ " Range NO, : "Fp~ ' 14-5901-91 0 to 270% 14-5901-02 50 to 320°F 14-5901-03 50 to 5OO°F 14-5901-04 50 to IOOO°F 14-5901-05 10 to t60°C 14-5901-06 10 to 260°C 14-5901-07 0 to 525°C i THERMOMETERS - SPOT CHECK, i M A X - M I N , PTC ® Sub, ; ' diW 2° 2° 5° 10 ° 1° 2° 5° 3/4 : Each 45.51 45.51 45.51 45.51 45.51 45.51 45.51 I N C H DIAL, Similar to 14-5901 but with Max-MJn pointers to indicate lowest and highest temperatures reached during the thermometer's exposure. NIST certification available upon request. Cat. Ne~ 14-5902-01 14-5902-02 14-5902-03 14-5902-04 14-5902-06 14-5902-07 i Range, : "EpC O to 270°F 50 to 320°F 50 to 500°F 50 to IOOO°F 10 to 260°C 0 to 525°C gub.~ : dl~;i 2° 2° 5° 10 ° 2° 5° !aCK 48.98 48.98 48.98 40.08 48.98 48.98 14-5881 THERMOMETERS - SURFACE TEMPERATURE, PTC ® Thermometers are fully enclosed to protect bimetal from dirt and dust. Diameteris 2 inches. Requires either a small magnet clamp to hold it securely in place on non-horizontal steel or other ferrous metal surfaces, or heavy silicone grease which can be used to stick the thermometer to any flat surface. NIST certification available upon request. Cob No; i Range : "F/"C ~ Subi ~ ~ dlv~ : EaCh 14-5881-01 -50 to 250~F 2° 47.00 14-5881-02 -50 to 110°C 2° 47.00 14-5081-03 0 te 300°F 2° 47.00 14-5881-04 -10 to 150°C 2° 47.00 14-5801-05 70 to 370°F 2= 47.00 14-5881-06 20 to 180% 2° 47.00 MAGNET AND LEAF SPRING, FOR 14-5881 THERMOMETER Clampholdsthermometersecurely in placeon steelor otherferrous metals. Cat~ Ne~ Description : . ~ Each 14-5882-01 Magnetic Thermometer Clamp 5.00 THERMOMETER ADHESIVE-SILICONE, FOR 14-5881 THERMOMETER Silicone grease holds thermometer securely on any flat surface. Caf~ No~ 14-5983-01 Description i i Thermometer Adhesive Each 7.08 1173 THERMOMETERS 14-5903 THERMOMETERS - SURFACE, MINIATURE SPOT CHECK, PTC ® Designed to measure surface temperatures in limited space. Bimetallic sensor comes in close contact with surface to be measured, providing a very fast response time. Made of stainless steel, they are rugged and will hold calibration indefinitely unless mishandled. Dial face (3/4 inch) and graduations are fired ceramic on stainless steel. An ancillary pointer is held by a magnetic clutch and indicates the highest or lowest temperature reached in a given period. It withstands vibration and jarring of normal use and can be reset indefinitely. Ideal for testing temperatures of electronic parts as well as heat exchangers, circulating ovens, lab heaters, hot plates, etc. NIST certification available upon request. 14-5003-01 14-5963-02 14-5903-03 14-5903-04 14-5903-05 14-5903-06 : °+ 0 to 250°F 0 to 5OO°F 50 to 750°F 0 to 135°C 0 to 275°C ' 10 to 4OO°C Sub~: dr. ~ ~ 2° 5° 10 ° 5° 5° 5° hock 43.73 43.73 43.73 43.73 43.73 43.73 14-5695 THERMOMETERS - TANK, SCOOP-MASTER One piece non-sparking cup-case molded out of a smooth, black, heat and chemical resistant plastic. The cup capacity of 120 mL meets with API and ASTM requirements. The scale is engraved on the tube for greater accuracy. The permanently etched thermometer tubes are furnished in Yellow Lens tubing for easier reading. Tube is held in place by spring clips, and can be replaced without tools. Overalllength, 355 mm. Cat. No. Complete 14-5695-01 14-5605-02 14-5695-03 14-5695-04 14-5695-05 14-5695-06 14-5695-07 14-5695-08 Range, °F/oC Div., °F/°C ASTM No. Each -30 to 120°F 0 to 180°F 20 to 220°F 176 to 500°F -34 to 49°6 -18 to 82°C -7 to 105°C 77 to 260°C 1.O°F 1.0°F 1,0°F 20% 0.5°C 05°C 0,5°C 1.0°6 58F 59F 130F 60F 58C 59C 130C 60C 75.66 75.60 75,60 83.66 75.60 75.60 75.60 83.66 Cat. No. 1174 Each 21.42 21.42 25.30 34.44 21.42 21.42 25.30 34.44 BACK The 355 mm long cases are made form hardwood that is lacquered to prevent absorption of the sample. The 100 mL capacity brass cup is non-sparking. Thermometers are identical with those supplied with 14-5695 Seoopmaster, and are similarly mounted with easily maneuverable spring clips. 14-5696-01 -30 to 120°F 14-5696-02 0 to 1800F 14-5696-03 20 to 220°F 14-5696-04 170 to 500°F 14-5696-05 -34 to 49% 14-5696-06 -18 to 82°C 14-5696-07 -7 to 105% 14-5696-08 77 to 260°C Note: See 14-5700forrefills ASTM Noi Replacement Thermometers- for 14-5695 and 14-5696 14-5700-01 -30 to 120°F 58F 14-5700-02 0 to 180% 59F 14-5700-03 20 to 220°F 130F 14-5700-04 170 to 50O°F 60F 14-5700-05 -34 to 49°C 58C 14-5700-06 -18 to 82% 59C 14-5700-07 -7 to 105°0 130C 14-5700-08 77 to 260% 600 14-5696 THERMOMETERS - TANK, W O O D Range, °F/°C , ;Ely;,. F/c:, 1.0°F 1.0°F 1.0°F 2.0°F 05°C 0.5°0 0.5°C 1.0+6 RSTm ~ NO 58F 59F 130F 60F 580 59C 130C 60C + Each 70.56 70.56 70.66 79.48 70.56 70.56 70.58 79.48 14-5936 THERMOMETERS - WEATHERING TEST Precision thermometers manufactured according to specifications of the California Natural Gas Association for weathering tests of fabrics and other materials. Cat. No. 14-5936-01 14-5936-02 Range, OF 0 to 45 -70 to 0 Suhdiv., Length, Immersion, °F mm mm 0,2 0.5 395 345 37 115 Each 31.18 62.37 THERMOMETERS rIMER 22-3040 HYGROMETER/THERMOMETER - DIAL 22-3468 Provides humidity and temperature readings in an easy-to-read dJal format. Large 6-inch diameter analog face displays 0 to 100% relative humidity and temperature from -40 ° to 122°F (-40 ° to 50°C). Temperature resolution is 1° and accuracy is _+1.5%. Humidity resolution is 1%RH and accuracy is _+2.5% at 5O%RH. Ideal for constantly monitoring labs, hallways, walk-ins, storage facilities, and plant areas. Self-contained unit is stable, accurate and requires no adjustment or maintenance. Supplied complete with screw for wall mounting. Size is 6-inch diameter x 1 inch and weight is 8 ounces. Cat : 22-3040-01 : : : Each Dial Hygrnmeter/Therrnometer 71.22 CLOCKS - ELECTRIC, 2 4 H O U R , TYPE LABORATORY WALL Clock has standard 12 hour black numbered outer dial with inner ring of balance of 24 hours in red. White background. Clear plastic lens. Diameter of dial, 12 inches. Housed in slim, 2 V2 inch deep case. Available in quartz or regular 120 volts, 60 Hz, AC. UL listed. Quartz clocks require one "AA" battery (not supplied). Cat, NQ 22-3468-02 22-3468-04 Dial dia., Type Reg electric Quartz ini 12 12 Eech 44.78 55.78 ELECTRIC STOP TIMERS THERMOMETER RACKS 22-3710 14-4375 THERMOMETER T I M E R - KWIK-SET, L A B - C H R O N , RACK - POLYPROPYLENE Suitable for holding up to 25 thermometers in the correct vertical position, thus avoiding mercury separation, which often occurs when thermometers are improperly stored. Manufactured from V4 inch polypropylene, the rack is sturdy and will not tip. Sides have large comfortable carry handles. The top and middle plates have 5/~6 inch hole diameters. The bottom plate has convenient V8 inch diameter drain holes. Overall dimensions are 8 x 10 x 5 3/4 inches deep. The entire rack is steam autoclavable. Cat;: N~ 14-4875-01 : : Descr ptlod ~::~ : Thermometer Reck : :: Each, LAB-LINE Unit features a high torque, synchronous motor which assures consistent accuracy regardless of voltage fluctuations or line load. The large, illuminated timing switch requires only a light touch for operation. Pushbutton reset instantly returns all numbers to zero; electric brake. Steel housing is finished in baked enamel and measures 7 x 4 x 4 inches high. With 6 foot, 3-wire cord and plug. 15-month warranty. For operation on 120 volts, 60 Hz, AC, 30 watts, Cat. No 22-3710-D1 T merrange Dial divisiQa$ EaCh To gggg.g seconds 0.1 second 311.85 30.95 1175 TENSIOMETERS c0 22-2840 TENSIOMETER - PRECISION, D U N O U Y , CSC 22-2845 TENSIOMETER - INTERFACIAL, D U N O U Y , CSC Similar to 22-2840 except has graduated dial which reads in both directions from zero and a double vernier is provided. The two scales and corresponding verniers are different colors to indicate upward or downward measured force. The 6 cm ring and its supporting frame are made of platinum-iridium wire and welded, includes metal case and instructions. Weighs 27 pounds. : : 22-2845-51 Each Interfacial Tensiometer 4005.75 TENSIOMETER REPLACEMEf,ITS/ACCESSORIES - FOR 22-2845-01 The 6 cm replacement platinum-iridium tensJometer ring has stirrup with parallel sides that are 25 mm high to permit the ring to be used in upward and downward interfacial measurements as well as surface tension measurements. Mean circumference is approximately 6 crn indicated to 3 significant figures, and is marked with the ratio of the radii of the ring and cross section of the wire. Packed with stirrup in a protective container. Adjustable ring alignment joint is used for easy and rapid leveling of ring. Joint is slipped into the socket of the vertical limb of the tensiometer and then the ring is inserted into the socket of the joint. Joint allows the plane of the ring to be adjusted parallel to the surface of the liquid. 22-2848-01 Steel Torsion Wire, pkg/3 22-2847-01 6 cm Platinum-Iridium Tensiometer Ring 22-2848-01 Ring Alignment Joint 22-2841 ~ ii! [a(h; 22.85 395.70 138.60 Provides precise readings of upward interracial and surface tensions by the ring method to values reproducible within -+0.05 dyne/era. This instrument is specified for determining interfacial tension of oil against water by the ring method in ASTM D97t and solutions of surface-active agents in ASTM Dt331. It is also specified for testing synthetic rubber lattices in ASTM D1417 and determining the surface tension of industrial water and wastewater in ASTM D1590. Completely assembled with torsion wire and platinum-iridium ring. Includes metal case and instructions. Weighs 27 pounds. Cal. No. 22-2840-01 Descriplien 3375.00 TENSIOMETER REPLACEMENTS/ACCESSORIES-FOR 22-2840-01 The 4 cm platin um-irtdium tensiometer ring makes all surface tension measurements when used in conjunction with 22-2840 Tensiometer. It has a mean circumference of approximately 4 cm indicated to 3 significant figures, and is marked with the ratio of the radii of the ring and cross section of the wire. The replacement 6 cm platinum-iridium tensiometer ring has stirrup with parallel sides that are 25 mm high to permit the ring to be used in upward interracial as well as surface tension measurements. Mean circumference is 6 cm. Both are packed with stirrup in a protective container. Cat. No. 22-2841-01 22-2842-01 22-2842-02 Description Each Steel Torsion Wire, pkg/3 16.00 4 cm Platinumdridium Tensiometer Ring 393.75 6 cm Platinum-iridium Tensiometer Ring 393.75 SEE OUR BALANCE ACCESSORIES Balance Tables, Balance Weights, Forceps, Weighing Boats, Weighing Dishes, Weighing Funnels, Weighing Papers 1148 Each Precision Tensiometer THERMOMETERS ASTM THERMOMETERS .l:z 14-5010 ASTM THERMOMETERS The liquid-in-glass thermometers in this listing conform to ASTM E 1 specifications and also to current Institute of Petroleum specifications for accuracy, materials and construction. All thermometers have serial numbers, and therefore are traceable to NIST specifications. Etched scales and numerals have pigments that are specially selected for permanency and resistance to common solvents. ,NG. : : 14-5010-81 14-5012-01 14-5014-01 14-5016-01 14-5018-01 14-5020-01 14-6022-01 14-5024-01 14-5026-01 14-5025-01 14-5030-01 14-5032-01 14-5034-01 14-5036-01 14-5038-01 14-5040-01 14-5042-01 14-5044-01 14-5046-01 14-5048-01 14-5050-01 14-5052-01 14-5054-01 14-5056-01 14-5050-01 14-5060-01 14-5062-01 14-5064-01 14-5066-01 14-5068-01 14-5070-01 14-5072-01 14-5074-01 14-5076-01 14-5078-01 14-5080-01 14-5082-01 14-5084-01 14-5086-01 14-5080-01 14-5090-01 14-5092-01 14-5094-01 14-5096-01 14-5098-01 14-5100-01 14-5102-01 14-5104-01 14-5105-01 14-5106-01 14-5107-01 : ASTM ~ ~ : , N~.: : : : Descdptlan 1C Partial Immersion 1F Partia] Immersion 2C Partial Immersion 2F Partial Immersion 3C Partial Immersion 3F Partial Immersion 4C Acid Heat 4F Acid Heat 5C Cloud and Pour 5F Cloud and Pour 6C Low Cloud and Poor 6F Low Cloud and Pour 7C Low Distillation 7F Low Distillation 8C High Distillation 8F High DistilLation 9C Pensky-Martens (Low) 9F Pensky-Martens (Low) 10C Pensky-Martens (High) 1OF Pensky-Martens (High) 11C Cleveland Open Flash 11F Cleveland Open Flash 12C Density (Wide Range) 12F Density (Wide Range) 13C Loss on Heat 14C Paraffin Wax Melting Point 14F Paraffin Wax Melting Point 15C Low Softening Point 15F Low Softening Point 16C High Softening Point 16F High Softening Point t7C Saybo[t Viscosity 17F Saybolt Viscosity 16C Saybolt Viscosity 18F Saybolt Viscosity 19C Saybolt Viscosity tgF Saybolt Viscosity 2OC Saybolt Viscosity 20F Saybolt Viscosity 21C Saybott Viscosity 21F Saybolt Viscosity 22C Oxidation Stability 22F Oxidation Stability 23C Engler Viscosity 24C Engler Viscosity 25C Engler Viscosity 26C Stabgity Test of Soluble Nitrocellulose 270 Turpentine Distillation 28C Kinematic Viscosity 28F Kinematic Viscosity 29C Kinematic Viscosity Scde ~ renge -20 to 150°C 0 to 3020F -5 to 300°C 20 to 580°F -5 to 400°C 20 to 760% -1 to 105°C 30 to 220% -38 to 50°C -36 to 1200F -80 to 20°C -112 to 7g°F -2 to 3OO°C 30 to 580°F -2 to 400°D 30 to 760°F -5 to 110°C 20 to 230°F 90 to 370°C 200 to 7OO°F -6 to 400°C 20 to 760°F -20 to 102% -5 to 215°E 155 to 170°C 38 to 82% 100 to 180°F -2 to 80°C 30 to 180°F 30 to 20O°C 85 to 392°F 19 to 27% 66 to 80°F 34 to 420C 94 to 108°F 49 to 57°C 120 to 134°F 57 to 65°C 134 to 148°F 79 to 87°C 174 to 158% 95 to 1030C 204 to 2180F 18 to 28°C 39 to 54°C 95 to 105°0 130 to 1400C 147 to 102°0 36.6 to 39.4% 97.5 to 102.5°F 52.6 to 55.4°C Subdivisions 10°C 2.00F 1.0% 20°F 1.0% 2.0°F 0.5°C 1.0°F I.O°C 2.0% 10°C 2.00F 1.0°C 2.0°F 1.0°C 2.0°F 0.5°C 1.O°F 2,O°C 5O°F 2.0°C 60°F 0.2% 0.5°F 0.5°C 0.1°C O.2°F 0.2°C O.5°F O.5°C I.O°F O.t°C O.2°F 0.1°C 0.2°F O.I°C O.2°F 0.1°C O.2°F 0.1% O.2°F O.l°C 0.2°F 0,2°0 O.2°C 02°C 0.1°C 0.5% O.05°C O.l°F O.05°C Length, : mm , mmhrslen Each 322 76 mm 22.23 322 76 mm 23.31 390 76 mm 28.76 390 76 mm 23.36 415 76 mm 34.87 415 76 mm 52.89 381 152 mm 31.69 381 152 mm 31.09 230 108 mm 24.81 230 108 mm 20.41 230 76 mm 30.83 230 76 mm 34.74 385 Total 29.61 385 Tota~ 29.59 385 Total 34.89 385 Total 30.29 290 57 mm 25.54 290 57 mm 27.71 290 57 mm 33.19 290 57 mm 33.19 310 25 mm 82.79 310 25 mm 32.79 420 Tota~ 38.96 420 Total 35.59 155 Total 55.07 375 79 mm 52.39 375 79 mm 41.60 395 Total 32.67 395 Total 32.57 395 Total 85.36 395 Total 35.36 275 Total 28.31 275 Total 28.29 275 Total 26.95 275 Total 26.96 275 Total 26.95 275 Total 26.96 275 Total 27.03 275 Total 25.81 275 Total 25.81 275 Total 81.00 275 Total 28.91 275 Total 26.94 212 90 mm 44.50 237 90 mm 44.50 212 90 mm 68.21 463 Total 66.21 301 76 mm 57.61 305 Total 120.96 305 Total 104.96 305 Total 120.90 (continued on next page)] ] 49 THERMOMETERS A S T M THERMOMETERS (continued from previous page) Description 14-5108-01 14-5110-01 14-5112-01 14-5110-01 14-5118-01 14-5120-01 14-5122-01 14-5124-01 14-5128-01 14-5120-01 14-0130-01 14-5132-01 14-5134-01 14-5136-01 14-5138-01 14-5145-51 14-5141-01 14-5142-01 14-5143-01 14-5144-01 14-5145-01 14-5146-01 14-5147-01 14-5148-01 14-5149-01 14-5150-01 14-5151-01 14-5152-51 14-5154-01 14-5158-01 14-5150-01 14-5160-01 14-5164-01 14-5165-01 14-5166-01 14-5170-01 14-5172-01 14-5174-01 14-5176-01 14-5177-01 14-5178-01 14-5179-01 14-5180-01 14-5181-01 14-5182-01 14-5183-01 14-5184-51 14-5186-01 14-5190-01 14-5192-01 14-5194-01 14-5196-01 14-5198-01 14-5200-01 14-5202-01 14-5204-01 14-5206-01 14-5208-01 14-5210-01 14-5212-01 14-5214-01 14-5216-01 14-5218-01 14-5220-01 14-5222-01 14-5224-01 14-5225-01 14-5226-01 14-5227-01 1150 Scale range 2gP Kinematic Viscosity 127.5 to 132.5°F 35F Kinematic Viscosity 207.5 to 212.5°F 31F Reid Vapor Pressure -30 to 120°F 330 Low Aniline Point -38 to 42°C 33F Low Aniline Point -36,5 to 107.5°F 340 Medium Aniline Point 25 to 105°C 34F Medium Aniline Point 77 to 221°F 35C Aniline Point 90 to 170°C 35F Aniline Point 194 to 338°F 360 Titer Test -2 to 68°C 370 Solvents Distillation -2 to 52°0 380 Solvents Distillation 24 to 78°C 390 So~vents Distillation 48 to 102°C 400 Solvents Distillation 72 to 126°C 41C Solvents Distillation 98 to 152°C 420 Solvents Distillation 95 to 255°C 430 Kinematic Viscosity -51.6 to -34°C 43F Kinematic Viscosity -61 to-29°F 440 Kinematic Viscosity 18.6 to 21.4% 44F Kinematic Viscosity 66.5 to 71.5°F 450 Kinematic Viscosity 23.6 to 26.4°C 45 F Kinematic Viscosity 74.5 to 79.5°F 460 Kinematic Viscosity 48.5 to 51.4"0 46F Kinematic Viscosity 119.5 to 124.5°F 470 Kinematic Viscosity 58.5 to 61.4°C 47F Kinematic Viscosity 137.5 to 142.5°F 480 Kinematic Viscosity 80.6 to 83.4°C 48F Kinematic Viscosity 177.5 to 182.5°F 490 Stormer Viscosity 20 to 70°C 50F Gas Calorimeter Inlet 54 to 101°F 51F Gas Calorimeter Outlet 69 to 116°F 52C ButadieneBoiling Point Range -10 to 5°0 530 BenzeneFreezing Point (1969) -0.6 to 10.4°C 540 Congealing Point 20 to 100.6°0 54F Congealing Point 68 to 213°F 560 Bomb Calorimeter 19 to 35°C 56F Bomb Calorimeter 66 to g5°F 570 Tag Closed Tester Low Range -20 to 50°0 57F Tag Closed Tester Low Range -4 to 122°P 580 Tank Low -34 to 49% 58F Tank Low -30 to 120°F 590 Tank Medium -18 to 82°C 59F Tank Medium 0 to 180°F 600 Tank High 77 to 260°C 60F Tank High 170 to 500°F - Case w/Cup only for all "Tank"Thermometers 610 Petrolatum Melting Point 32 to 127°C 61F Petrolatum Melting Point 90 to 260°F 620 Precision* -38 to 2°C 030 Precision* -8 to 32°C 640 Precision* 25 to 55°C 650 Precision* 50 to 8O°C 660 Precision* 75 to 105°C 670 Precision* 95 to 155°C 680 Precision* 145 to 205°C 690 Precision* 195 to 305°C 700 Precision* 295 to 405% 62F Precision* -36 to 35°F 63F Precision* 18 to 09°F 64 F Precision* 77 to 131°F 65F Precision* 122 to 176°F 66F Precision* 107 to 221°F 67F Precision* 203 to 311°F 68F Precision* 293 to 401% 69F Precision* 383 to 501°F 70F Precision* 563 to 761% 710 Oil in Wax -37 to 21°C 71F Oil in Wax -35 to 70°F 72C Kinematic Viscosity -19.4 to -16.6°C Subdivisions Length, mm 0.1% 0.1°P 1.5°F 0.2°C 0.5°F 0.2°C O.5°F 5.2% 5.5% 0.2°C 0.2°C 0.2% 0.2°C 0.2% 0.2°C 0.5°C 0.1°C 0.2°F 0.05°C 5.1% 0.55% O.I°F 0.05% 0.1°F 0.05°C O,l°F 0,0500' O.I°F 0.2% 0.1% O.l°F 0.1°C 0.1% 0.2°C O,5°F O.O2°C O.05°F 0.5% 1.0°F 0.5°C 1.O°F 5.5% 1.0°F 1.0°0 2.0°F 0.2°C 0.5°F O.l°C O.I°C 5.1°C 0.1°C 0,1% O.2°C 0.2°C 0.5°C O.5°C O.2°F 5.2% O.2°F O.2°F O,2°F O,5°F O.5°F 1.0°F 1.0°F 0.5°C I.D°F 0.05°C 305 305 305 420 420 420 420 420 420 405 395 395 395 395 395 395 420 421 305 355 305 305 305 305 305 305 305 305 305 468 468 162 189 310 310 585 585 287 287 303 303 303 303 303 303 380 380 379 379 379 379 379 379 379 379 379 379 379 379 379 379 379 379 379 379 355 355 305 Immersion Each Total 120.06 Total 112.04 Total 21.40 50 rnm 43.59 50 mm 43.88 50 mm 43.58 50 mm 48,82 51 mm 46.21 51 mm 46.21 45 mm 48,54 100 mm 51.84 100 mm 51.04 100 mm 51.04 100 mm 01.94 100 mm 51.94 100 mm 51.04 Total 227.80 Total 207.69 Total 104.21 Total 104.14 Total 104.13 Total 104.13 Total 184.13 Total 104.13 Total 104.14 Total 104.14 Total 117.70 Total 104.14 65 mm 51.36 Total 81.51 Total 84.01 Total 57.14 Total 48.11 Total 50.93 Total 00.93 Total 153.64 Total 153.64 57 mm 26.41 57 mm 26.41 Total 21.69 Total 21.63 Total 21.63 Total 20,43 Total 28.09 Total 28.09 45.00 79 mm 39.89 79 mm 39.89 Total 184.74 Total 213.29 Total 263.47 Total 174.89 Total 201.21 Total 201.03 Total 236.64 Total 271.04 Total 307.04 Total 184,74 Total 108.99 Total 174.87 Total 174.87 Total 201.21 Total 210.70 Totot 232.76 Total 273.01 Total 307.04 76 mm 38.13 76 mm 30.13 Total 133.65 (continued on next page) THERMOMETERS ASTM THERMOMETERS (continued from previous page) C~|~: :: : Stole NQ, 14-5228-01 14-5229-01 14-5230-01 14-5231-01 14-5232-01 14-5234-01 14-5236-61 14-5238-61 14-5240-01 14-5242-01 14-5244-01 14-5246-01 14-5240-01 14-5250-01 14-5252-01 14-5254-01 14-5256-01 14-5258-01 14-5260-01 14-5262-01 14-5264-01 14-5266-01 14-5268-01 14-5270-01 14-5272-01 14-5274-01 14-5276-01 14-5278-01 14-5280-01 14-5282-01 14-5284-01 14-5286-01 14-5288-01 14-5290-01 14-5291-01 14-5292-01 14-5293-01 14-5294-01 14-5295-01 14-5296-01 14-5298-01 14-5300-01 14-5302-01 14-5304-01 14-5306-01 14-5308-01 14-5310-01 14-5312-01 14-5314-01 14-5316-01 14-5318-01 14-5319-61 14-5320-01 14-5322-01 14-5324-01 14-5326-01 14-5327-01 14-5328-01 14-5905-01 14-5910-01 14-5332-01 14-5333-01 14-5334-01 14-5335-01 14-5336-01 14-5337-01 14-5338-61 14-5339-01 14-5340-01 72F Kinematic Viscosity 73C Kinematic Viscosity 73F Kinematic Viscosity 74C Kinematic Viscosity 74F Kinematic Viscosity 75F Antifreeze Freezing Point 76F Antifreeze Freezing Point 77F Saybolt Viscosity 78F Saybott Viscosity 79F Saybolt Viscosity 80F Saybolt Viscosity 81F Saybolt Viscosity 82C Fuel Rating, Engine 83C Fuel Rating, Air 84C Fuel Rating, Orifice, Tank 85C Fuel Rating, Surge 86C Fuel Rating, Mix 87C Fuel Rating, Coolant 82F Fuel Rating, Engine 83F Fuel Rating, Air 84F Fuel Rating, Orifice, Tank 85F Fuel Rating, Surge 86E Fuel Rating, Mix 87F Fuel Rating, Coolant 88C Vegetable Oil Flash 88F Vegetable Oil Flash 89C Solidification Point 9OC Solidification Point 91C Solidification Point g2C Solidification Point 93C Solidification Point 94C Solidification Point 95C Solidification Point 96C Solidification Point 97C Tank 97F Tank 98C Tank 98F Tank 99C Weathering Test 99F Weathering Test _ Non-sparking Armor for Above 100C Solidification Point 101 C Solidification Point 102C Solvents Distillation 103C Sofvents Distigation 104C Solvents Distillation 105C Solvents Distillation 106C Solvents Distillation 107C Solvents Distillation 108F Saybolt Viscosity 109F Saybolt Viscosity 110 C Kinematic Viscosity 11 OF Kinematic Viscosity 111C Tar Acids Distillation 112C Solidification Point Benzene 113C Softening Point (Bitumen) Wide Range !13F Softening Point (Bitumen) Wide Range 114C Aviation Fuel Freezing Point 1 t 5CU BeckmanDifferential Upward 115CD BeckmanDifferential Downward 116C Bomb Calorimeter 117C Bomb Calorimeter 1 t 8C Kinematic Viscosity 118F Kinematic Viscosity 119C Antifreeze Freezing Point 119F Antifreeze Freezing Point t 2gc Kinematic Viscosity 121 C Kinematic Viscosity 122C Brookfiefd Viscosity -2.5 to 2.5°F -41.4 to -38.6°C -42.5 to -37.5°F -55.4 to -52.6°C -67.5 to -62.5°F -35 to 35°F -65 to 5°F 245 to 265°F 295 to 315°F 345 to 365°F 395 to 415°F 445 to 465°F -15 to 105°C 15 to 7O°C 25 to 80°C 40 to 150°C 95 to 175°C 150 to 205°C 0 to 220°F 60 to 160°F 75 to 175°F 100 to 300°F 200 to 350°F 300 to 400°F 10 to 209°C 50 to 392°F -20 to 10°C 0 to 30°C 20 to 50°C 40 to 70°C 60 to 90°C 80 to 110% 100 to 130°C 120 to 150°C -18 to 49°C 0 to 1BO°F 16 to 82°C 60 to 180°F -50 to 5°C -55 to 40°F 145 to 205°D 195 to 305°C 123 to 177°C 148 to 202°C 173 to 227°C 198 to 252°C 223 to 277°C 248 to 302°C 270 to 290°F 320 to 340°F 133.6 to 136.4°C 272.5 to 277.5°F 170 to 250°C 4 to 6°C -1 to 175°C 30 to 350°F -80 to 20°C 0 to 6°C 6 to O°C 18.9 to 25.1°C 23.9 to 30.1°C 28.6 to 31.4°C 33.5 to BS.5°F -38.3 to -30°C -37 to -22°F 38.5 to 41.5°C 98.5 to 101.4°C -45 te -35°C Sub:divisions 0.1°F O.05°C 0.1°F O.05°C Olt°F O.5°F O.5°F O.5°F O.5°F O.5°F O.5°F O.5°F 1.0°C 1.0°C 1.0°C 1.0°C 1.0°C I.O°C 2.0°F t.O°F 1.0°F 2.O°F 2.O°F I.O°F 1.0°C 2.0°F O.I°C O.I°C B.I°C 0.1°C 0.1°C 0.1% 0.1% O.I°C g.5°C 1.0°F B.5°C 1.0°F 0.20C O.5°F O.2°C 0.5°C 0.2°C O.2°C 0.2°C O.2°C O.2°C 0.2°C O.5°F g.5°F 0.05% B.I°F 0.2°C O.O2°C 0.5°C 1 .g°F 0.5°C O.Ol°C 001°C O.Ol°C B.Ol°C 0.05°C 01°F 0.1°C O.2°F O.05°C 005°C O.I°C Length ~ mm 305 305 305 305 305 408 408 275 275 275 275 275 162 171 383 310 167 172 162 171 383 310 167 172 287 267 370 370 370 370 370 370 370 370 303 303 303 303 302 302 * 370 370 395 395 395 395 395 395 275 275 305 305 395 215 405 405 300 640 640 609 609 305 305 420 420 305 305 300 Each Total 121.24 Total 234.70 Total 234.71 Total 256.09 Total 225,71 ,~m 100 mm 60.23 100 mm 180.86 Total 38.13 Total 44.62 Total 38.13 Total 44.62 Total 44.62 30 mm 33.90 40 mm 33,96 249 mm 35.43 181 mm 35.41 35 mm 40.49 40 mm 40.49 30 mm 33.96 40 mm 33.96 249 mm 33.43 181 mm 35.41 35 mm 40.40 40 mm 40.49 57 mm 38.51 57 mm 33.51 76 mm 80.21 76 mm 48.04 76 mm 46.26 76 mm 47.73 76 mm 47.73 76 mm 47.73 76 mm 46.83 76 mm 48.34 Total 27.13 Total 27.13 Total 27.13 Total 27.13 35 mm 132.30 35 mm 150.31 35.00 76 mm 46.21 76 mm 53.71 100 mm 51.81 100 mm 31.84 100 mm 51.83 100 mm 49.64 100 mm 51.07 100 mm 54.13 Total 37.91 Total 36.14 Total 120.54 Total 120.54 100 mm 97.03 Total 97.03 Total 36.60 Total 36.80 Total 38.70 Total 454.30 Total 420.00 Total 201.80 Total 201.80 Total 102.69 Total 223.50 100 mm 211.68 100 mm 223.50 Total 103.27 Total 115.21 Total 115.21 (continued on next page) 1151 qr.n THERMOMETERS ASTM THERMOMETERS (continued from previous page) Scale SubLength, ,.. divisions m 14-5342-01 123C Brookfield Viscosity -35 to -25°C 8.1°C 300 14-5344-01 124C Brookfield Viscosity -25 to -15°C 0.1°0 300 14-5346-01 125C Brookfield Viscosity -15 to -5°C 0.1°0 300 14-5348-01 126C Kinematic Viscosity -27.4 to -24.6°C 8.05% 305 14-6549-01 126F Kinematic Viscosity -17.5 to -12.5°F O.I°F 305 14-5356-61 1270 Kinematic Viscosity -21.4 to 18.6% 0.05°C 305 14-5352-61 1280 Kinematic Viscosity -1.4 to 1.4% 0.05°C 305 14-5353-01 123F Kinematic Viscosity 29.5 to 34.5°F 0.1°F 305 14-5364-01 t29C Kinematic Viscosity 91.6 to 94.4% 0.05°0 305 14-5355-01 129F Kinematic Viscosity 197.5 to 202.5°F O.I°F 305 14-5356-01 1300 Tank -7 to 105°0 9.5°0 303 14-5357-01 t30F Tank 20 to 220°F 1.0°F 303 14-5356-01 f32D Kinematic Viscosity 148.6 to 151.4°C 0.08°C 305 * Thermometer sets available for 62-78C and 62-701:, see 14-4665. MERCURIAL THERMOMETERS 14-466e THERMOMETER SET - ASTM, PRECISION, CALIBRATED These sets of thermometers cover the range from -38 to 405°C or -36 to 761°E Each set consists of 9 thermometers in a felt-lined leatherette case, Each thermometer has been calibrated against NIST standards and comes with a calibration document showing corrections to the nearest tenth of a scale division traceable to NIST. Each incorporates the ice point (0% or 32°F) as a reference point. This enables the user to validate and update the calibration document, to insure accurate measurements over the life of the thermometer. Each set contains nine ASTM thermometers Nos. 62-70C or 62-70E 14-4665-01 ASTM Nos. 62 - 700 2412.16 14-4665-02 ASTM Nos. 62 - 7OF 2412.16 Note:lndividualreplacementthermometers are also available SEE OUR SELECTION OF APPARELAprons, Boot/Shoe Covers, Coats/Smocks, Coveralls, Hoods/Head Covers, Sleeves 1152 Immersion Total Total Total Total Total Total Total Total Total Total Total Total Total Each 115.21 115.21 115.21 151.60 151.60 151.60 127.30 127.30 119.00 119.00 34.96 34.98 119.00 REUNITING SEPARATEDMERCURYCOLUMNS* The largestsingle causefor the failure of precisionthermometers in the lab is due to separated mercury columns. This can occur in transif or in the lab. The life of the instrument can be greatly extended if the following proceduresare rigidly employed. Other methods may cause damage to the thermomete~ A. COOLINGMETHOD: With the thermometerin an updght position gradually immerse ONLYthe bulb in a solution of solid CO (Dry-Ice) and alcohol so that the mercury column retreatsslowly into the butb. Do not cool the stem or mercury column. Keepthe bulb in the solution until the main column as well as the separated portion r~re~s into the bulb. Removeand swing thermometer in short arc forcing all the mercury into the bulb. Most mercury thermometerscan be reunited using this method regardless of range (with the exception of deep immersion thermometere) provided ONLYTHE BULB is immersed in the CO2 CAUTION: 1. Do not touch the bulb until it has warmed sufficiently for the mercury to emerge from the bulb into the capillary. 2. Never subject the stem or mercury column to the CO solution as it will freezethe mercury column in the capillaryand may causei~e bulb to fraofure. B. HEATING METHOD: This method applies to thermometers with a maximum range of 260% or 500°F, equipped with expansion chambers sufficiently large to accommodate the separ~ion plus a portion of the main column. Immerse as much of bulb AND STEMas possible in a large beakercontaining a liquid whose flash point is well abovethe highest indication of the thermometer being reunifed. Heat the beakerstirring the liquid with the thermometer until the separation and a portion of the main column enter the chambe~ Tap thermometer in palm of gloved hand reuniting column. Allow to cool slowly. CAUTION: 1. Never use open flame on bulb. 2. Never fill expansion chamber more than 2/3 full. 3. Make certain Flash Point of liquid is well above highest temperature ndicated on the thermometer. 4. Thermometers WhOSe ranges exceed 260"0 or 500°F CAN NOT be reurereo using heat without damaging the instrument. *Courtesy of Ever Ready Thermometer Co., Inc. THERMOMETRIC INFORMATION Formulae for conversion of thermometer scales: Degrees C = (Degrees F - 32) x 5 9 Degrees F = (Degrees C x 9) + 32 5 Emergent stem correction (for total immersion mercury thermometers): Correction °C = 9.00016 n (T-t) Correction °F = 0.00009 n (T-t) n = The number o1 degrees of emergent mercury column. T = bulb temperature. [ = Mean temperature of emergent column. THERMOMETERS LAB GRADE THERMOMETER THERMOMETERS - YELLOW BACK, CELSIUS, MERCURIAL, LAB GRADE 14-4380, 14-4385 Made of seasoned normal glass tubing with yellow background. Scale is engraved on the stem which is 6 to 7 mm in diameter. Tolerances are within those set by NIST (NBS). Feature non-roll fittings; permanent markings; vertical numerals; toughened bulbs and safe-seal packaging. Cat, Na i: : Total Immersion 14-4465-01 14-4465-02 14-4465-93 14-4465-04 14-4465-05 Range "C : : Sub- " div,~ : LeRgth, mm : Each -35 to 50 -20 to 110 -20 to 150 -10 to 260 -10 to 400 1 1 1 1 2 305 305 305 405 405 11.65 11.23 11.55 16.43 19.63 76 mm Immersion 14-4470-01 -35 to 50 14-4470-02 -20 to 110 14-4470-03 -20 to 150 14-4470-04 -10 to 260 14-4470-05 -19 to 400 1 1 1 1 2 305 305 395 405 405 11.55 11.23 11.55 15.43 19.63 Cat~ Ha; R~ga C Total Immersion 14-4380-01 -35 to 50 14-4380-02 -20 to 110 14-4380-03 -20 to 150 14-4380-04 -10 to 260 14-4380-05 -10 to 400 14-4380-06 -10 to 500* 76 mm Partial Immersion 14-4381-01 -35 to 50 14-4381-62 -20 to 110 14-4331-03 -20 to 150 14-4381-64 -10 to 260 14-4381-05 -10 to 400 14-4381-06 -10 to 500* *White back borosilicate glass S.~ dlv. Length, mm : 305 305 305 405 405 405 23.90 23.90 28.90 32.30 38.60 96.60 1 1 1 1 2 2 305 305 305 405 405 405 23.90 23.90 23.90 32.30 38.60 96.60 THERMOMETERS - YELLOW BACK, FAHRENHEIT, MERCURIAL, PRECISION GRADE Like 14-4465, 14-4470 but Fahrenheit. Cat; No. : Total Immersion 14-4510-01 14-4516-02 14-4510-03 14-4510-04 14-4510-05 °FR"g e Sub" : dlv,° Length, rnm Each -30 to 120 0 to 230 0 to 300 20 to 500 20 to 750 1 2 2 2 5 305 305 305 405 495 11.55 11.23 11.55 15.43 19.63 76 mm Immersion 14-4515-01 -30 to 120 14-4515-02 0 to 230 14-4515-03 0 to 300 14-4515-04 20 to 560 14-4516-05 20 to 750 1 2 2 2 5 305 305 305 405 405 11.55 11.23 11.23 15.43 19.63 PRECISION GRADE THERMOMETERS The general purpose glass laboratory thermometers in this listing have been selected for specifications approved by the Scientific Apparatus Makers' Association in conjunction with the National Institute of Standards and Technology (NIST) formerly the National Bureau of Standards (NBS). They have been approved by Subcommittee V of ASTM E26-05 and also meet American National Standard Institute (ANSI) specifications. All thermometers listed are made from the finest thermometric glass available for strength, clarity and thermal sensitivity. Each is individually pointed at close intervals to assure accuracy over the entire range and has its own individual serial number. Partial immersion thermometers are calibrated (unless otherwise stated) for 76 mm immersion, measured from the bottom o1 the bulb. Nitrogen filled; suspension ring. Range °F Each 1 1 1 1 2 2 THERMOMETERS - YELLOW BACK, FAHRENHEIT, MERCURIAL Cah Noi (.n THERMOMETERS - YELLOW BACK, CELSIUS, MERCURIAL, PRECISION GRADE Sub, dtv.° Length,~ . . . . . . . . ram. Each Total Immersion 14-4385-01 -30 to 120 1 14-4385-02 O to 230 2 14-4385-03 O to 300 2 14-4385-04 20 to 500 2 14-4365-05 20 to 750 5 14-4385-06 20 to 930* 5 76 mm Partial Immersion 14-4386-01 -30 to 120 1 14-4386-02 O to 230 2 14-4386-93 0 to 300 2 14-4386-04 20 to 500 2 14-4366-05 20 to 750 5 14-4386-06 20 to 930* 5 *Available in white back borosilicate glass only THERMOMETERS - PRECISION, DOUBLE MERCURIAL, 7 6 M M IMMERSION 305 305 305 405 405 405 23.30 23.50 23.30 32.30 38.60 96.90 305 305 305 405 405 405 23.60 23.90 23.90 32.30 38,60 66.90 SCALE, Similar to 14-4381 series, except read in Celsius and Fahrenheit. Stems are 6 to 7 mm O,D. and bulbs do not exceed stem diameter. Nitrogen rests above the mercury, 14-4556-01 is 305 ram; others, 405 mm long. Tops are finished with suspension rings. Cot; 9nnge, NO; : C 14-4556-01 -20 to 110 14-4556-02 -10 to 260 14-4556-03 -10 to 400 THERMOMETER ARMORS Range, °F 0 to 230 20 to 500 20 to 750 sabdivv Subd!v., % °F Each 1 2 25.66 1 2 35.19 2 5 42.10 Thermometer armors only, made from heavy brass tubing, and nickel plated. With top suspension ring on the screw cap. Suitable for use with 14-4380 to 14-4556 thermometers. cat; ~ Na~ 14-4576"30 14-4576-35 " Forthermometer: length,In 12 16 Each 12.00 15.43 1153 THERMOMETERS 14-4650 ~1~ THEPJ~OMETERS - YELLOW BACK, MERCURIAL, FRACTIONAL DEGREE, PRECISION GRADE 14-4855 These fractional degree thermometers have an 0.D. of 6 to 7 ram. Bulbs do not exceed stem diameters, Nitrogen rests above mercury. Totallmmersion-Celsius 14-4659-92 -1 to 51 14-4659-93 -1 to 101 14-4650-04 -1 to 201 76 mm Immersion-Celsius 14-4655-92 -1 to 51 14-4655-03 -1 to 101 14-4655-04 - t to 201 01 0.1 0.2 460 510 610 68.40 84.60 93.60 0.t 0.t 0.2 460 610 610 6B.40 64.00 93.60 Totallmmersion-Fahrenheit 14-4650-12 -30 to 124 0.2 460 14-4650-13 -30 to 214 0.2 610 14-4550-14 -30 to 394 0.5 610 76 mm Immersion-Fahrenheit 14-4655-12 -30 to 124 02 450 14-4655-13 -30 to 214 0.2 610 14-4666-14 -30 to 394 0.5 610 Factory certified Thermometers traceable to NIST, available quest. Contact your local sales office for information. 68.46 84.00 93.60 68.40 54.00 93.60 on re- 14-4845 THERMOMETERS - CELSIUS, ADJUSTABLE BUSHING, ERT¢O Thermometers have an adjustable bushing with a standard taper of 10/ 18. A neoprene grommet at the top of the bushing permits the thermometer to slide through, allowing a variety of immersion lengths. Vapor temperatures and liquid temperatures may be taken alternately without dismantling equipment. The 6 inch immersion length can be used for flasks from 250 to 3000 mL, and the 12 inch for flasks from 5000 to 22,000 mL. Subdivided into 1°C divisions. Stems are yellow backed for good legibility. Individual serial number I.D. is on each thermometer. 14-4845-01 A 6 -10 to 250 56.80 14-4845-02 B 12 -10 to 250 76.66 14-4845-03 C 6 - t 0 to 380 64.15 14-4845-04 D 12 -10 to 360 78.64 THERMOMETER BUSHING Glass bushing with a 10/18 standard taper for replacement in 14-4845 thermometer. Includes neoprene grommet. 14-4850-01 1154 Thermometer Bushing 23.52 THERMOMETERS - CELSIUS, • 1 0 / 3 0 , GROUND JOINT, YELLOW BACK, PRECISION GRADE Available in 4 temperature ranges and 9 immersion lengths. The graduations and figures are clearly etched and offer a sharp contrast against the yellow background. Graduated in 1°C subdivisions. A special type of construction eliminates the distortion of the bore through the joint, and prevents the mercury column from separating along the taper. Serialized to insure traceability. 76 mm Imme~on 14-4855-01 14-4855-92 14-4855-03 14-4855-04 100 mm Imme~ion 14-4855-05 14-4855-06 14-4855-07 14-4855-08 125 mm Immersion 14-4855-09 14-4855-10 14-4855-11 14-4855-12 150 mm Immersion 14-4855-13 14-4855-14 14-4855-15 14-4855.16 190 mm Imme~ion 14-4855-17 14-4855-18 14-4855-19 14-4855-20 216 mm Immersmn 14-4855-21 14-4855-22 14-4855-23 14-4855-24 250 mm Immersion 14-4855-25 14-4855-26 14-4855-27 14-4855-28 280 mm Immersion 14-4855-29 14-4855-30 14-4855-31 14-4856-32 Range, -10°Cto °C Each 110 150 250 360 41.33 44.86 49.79 49.96 110 150 250 360 44.86 49.74 49.51 49.74 110 150 250 360 49,74 49.51 49.77 49,50 110 150 250 360 49.77 50.17 52.29 54.30 110 150 250 360 59.17 52.26 54.31 55.66 110 150 250 369 59.95 59.95 62.89 65.73 110 150 250 360 63.52 65.62 66.88 71.19 110 150 250 360 72.34 73.92 76.33 81.06 THERMOMETERS 14-4856 THERMOMETERS - CELSIUS, TEFLON ® COATED, ~; 1 0 / 3 0 , G R O U N D JOINT, YELLOW BACK, PRECISION GRADE 14-486S Similar to the 14-4855 series with the added feature of Teflon® coating to protect against shock as well as contamination in the event of accidental breakage. The entire instrument is coated with Teflon, with the exception of the ground joint. Accurate to within NIST (NBS) tolerances. Cet : : Range:: -lO'C :: ~ 75 mm Immersion 14-4856-01 14-4856-02 14-4856-03 100 mm Immersion 14-4856-04 14-4856-05 14-4856-06 125 mm Imme~ion 14-4856-07 14-4856-08 14-4856-09 150 mm Immersion 14-4856-10 14-4856-11 14-4856-12 190 mm Immersion 14-4856-13 14-4856-14 14-4856-15 215 mm Immersion 14-4856-16 14-4856-17 14-4856-18 250 mm Immerszon 14-4856-19 14-4856-20 14-4856-21 280 mm Immersion 14-4856-22 14-4856-23 14-4856-24 305 mm Immersion 14-4856-25 14-4856-26 14-4856-27 ;: (r.n THERMOMETERS - LONG IMMERSION TYPE, WITHOUT GROUND JOINT, YELLOW BACK Mercury filled, yellow backed, etched stem, available in -10 to 250°C and -10 to 360°C. Subdivisions on both ranges are 1°. Length of the 250% thermometers, exclusive of the immersion, is 11 inches; of the 360%, 12 inches. These thermometers can be used with the thermometer adapters shown under 14-6900 to 14-6950. ; i : -10 to 250°C 14-4865-22 14-4865-23 14-4865-24 14-4865-25 14-4865-26 14-4865-27 14-4865-28 14-4865-29 14-4865-30 4 5 6 7 8 g 10 11 12 41.47 43.57 45,36 47.77 48.51 50.29 51.13 55.44 56.38 -10 to 360°C 14-4866-22 14-4866-23 14-4866-24 14-4866-25 14-4866-26 14-4866-27 14-4868-28 14-4866-20 14-4866-30 4 5 5 7 8 9 10 11 12 43.57 45.04 44.70 50.92 52.71 56.17 58.90 60.16 60.16 110 150 250 45.36 48.30 52.39 110 150 250 49.14 50.40 53.13 110 150 250 50.08 58.02 55.96 110 150 250 55.96 57.22 59.43 116 150 250 59.53 61.42 64.89 110 150 250 67.72 67.72 70.56 THERMOMETERS - LOW TEMPERATURE, CELSIUS, RED LIQUID FILLED, TOTAL IMMERSION 110 150 250 71.29 53.02 74.65 Made of solid thermometer tubing having a diameter of 6 to 7 mm with expansion bulb and suspension ring. Liquid column is dyed red to facilitate reading. 110 150 250 80.22 81.58 84.21 110 150 250 86.73 87.88 90.61 Renp 14-4700-01 14-4700-02 ~ -100 to 50 -50 to 50 S U b - L e n g t h, 1 t 305 306 36.61 36.61 THERMOMETERS - CELSIUS, ~ 1 0 / 3 0 , GROUND JOINT, WHITE BACK, ORGANIC FILLED, PRECISION GRADE Similar to the 14-4855 series but with colored spirit filling in place of mercury. Ca NO. 14-4857-01 14-4857-02 14-4857-03 14-4887-04 14-4857-05 14-4857-06 14-4857-07 14-4857-08 : ; Range, % -10 -10 -10 -10 -10 -10 -10 -10 to to to to to to to to 110 150 110 150 110 150 110 150 Immersion, m 76 76 100 tO0 125 125 150 150 : Each 37.48 40.63 41.37 42.63 42.31 45.15 48.19 49.35 14-4780 THERMOMETER - LOW TEMPERATURE, CELSIUS, ORGANIC FILLED, PRECISION GRADE A total immersion thermometer filled with colored organic. Approximate length is 350 mm. Range is -200 to +30°0. graduated in 1° divisions. cat. : ~ : 14-4780-01 Low Temperature Thermometer 87.04 1155 THERMOMETERS REPLACEMENT THERMOMETERS Cat. No. 14-4852 THERMOMETERS - TOTAL IMMERSION, YELLOW BACK, RED LIQUID, ORGANIC FILLED, SAMA PRECISION GRADE Length is 305 mm. All thermometers are individually serialized. : i:: Sub, Range Each 14-4852-01 -20 to 110°C 1°C 25,09 14-4852-02 -20 to tSO°C 1% 25,09 14-4852-03 0 to 230°F 2°F 25.09 14-4852-04 0 1o 300°F 2°F 25.09 14-4852-05 35 to 50°C 1°C 08,57 14-4852-06 30 to 120°F l°F 25.00 Range,° Red Spirit Filled (For 14-4915) 14-4920-01 -30/120F 14-4920-02 +30/120F 14-4920-03 0/220F 14-4920-05 -35/50C 14-4020-06 -20/105C Mercury Filled (For 14-4916) 14-4921-01 -30/120F 14-4921-02 +30/120F 14-4921-03 0/220F 14-4921-05 -35/50C 14-4021-06 -20/105C SAFETY 25.09 25.09 25.09 27,30 25.09 25.09 25,09 25.09 14-4915 Available as red liquid filled or mercury filled. Cases are plated meta~ with pocket cJip. The metal tops in which thermometers are secured have metal rings for suspension. Length is 165 ram, with toughened bulb and permanent marking. 1156 ~ Rng~ :: Sub-~ dlv. : THERMOMETERS - SAFETY, TEFLON ® COATED, YELLOW BACK, MERCURIAL These 76 mm immersion thermometers are sealed in an inert, transparent Teflon® jacket which absorbs shock and prevents shattering. The jacket prevents contamination and also serves to retain the mercury and glass in case of breakage. Thermometers are 300 mm long. All thermometers are serialized; accurate to NIST (NBS) tolerances. Cat. No~ Range Sabdiv. Each 14-4387-01 -20 to 110% 1°C 37.22 14-4387-02 -20 to 150°C 1°C 37.22 14-4387-03 -10 to 200°C 1°C 37.22 14-4387-11 60 to 260°C 1°C 42.00 14-4387-04 0 to 230°F 2°F 37.22 14-4387-05 0 to 300°F 2°F 37.22 14-4387-06 20 to 400°F 2°F 37.22 14-4387-12 140 to 500°F 2°F 42.00 THERMOMETERS - SAFETY, TEFLON ® COATED, WHITE BACK, RED SPRIRIT FILLED THERMOMETERS - POCKET, WITH METAL CASE Ca N~ Red Spirit Filled 14-4915-01 14-4915-02 14-4915-03 14-4915-05 14-4915-06 Mercury Filled 14-4916-01 14-4916-02 14-4916-03 14-4916-05 14-4916-06 17.74 17.74 17.74 17.74 17.74 14-4387 Similar to 14-4852 but 76 mm immersion. All Celsius thermometers are in 1° divisions; all Fahrenheit thermometers are in 2 ° divisions. Length is 305 mm. -35 to 50°C -20 to 110% -20 to 150% -10 to 200°C -30 to 120°F -O to 230% 0 to 300°F 20 to 400°F 17.74 17.74 17.74 17.74 17.74 THERMOMETERS THERMOMETERS - PARTIAL IMMERSION, YELLOW BACK, RED LIQUID, ORGANIC FILLED, SAMA PRECISION GRADE 14-4853-01 14-4853-02 14-4853-03 14-4853-04 14-4853-05 14-4853-06 14-4883-07 14-4853-08 Each Each -30 to 120°F +30 to 120°F 0 to 220°F -35 to 50°C -20 to 105% 2°F l°F 2°F 1°C 1% 28.87 28,87 28.87 28.87 28.87 -30 to 120°F +30 to 120°F 0 to 220°F -35 to 50% -20 to 105°C 2°F I°F 2°F 1°C 1°C 25,41 28.87 28.87 25.41 25.41 Similar to 14-4387 except white back and red colored spirit filling. Cat; No. 14-4388-01 14-4388-02 14-4388-03 14-4388-04 14-4388-05 14-4388-06 14-4388-07 14-4388-08 14-4388-09 14-4388-10 Range. -20 to 110% -20 to 150% -10 to 2000C 0 to 230°F 0 to 300°F 20 to 400°F -50 to 50°C -100 to 50% -50 to 50°C -100 to 5g°c Subdi~ 1°C 1°C 1% 2°F 2°F 2°F t°C 1°C 1°C t°C Lenghl Immersian nun mm Each 300 76 37.22 300 76 37.22 305 75 37.22 300 76 37.22 300 76 37.22 305 76 37.22 305 76 38.95 305 76 87.85 305 Total 38.95 305 Total 57.85 THERMOMETERS DIAL-TYPE INDUSTRIAL THERMOMETERS T 14-5432 THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 2 1/2 INCH STEM Industrial grade back-connected bE-metallic 3 inch diameter dial is ideal for many applicatLons. Can be easily recalibrated with hex screw. Made o1 18-8 type 304 stainless steel with all welded construction. Stern diameter is r/4 with V2 inch NPT connection nut. Single scale in either °F or %. Actuated by super-sensitive bE-metallic helix coil. Bi-metallic element is dampened with silicone for minimum pointer vibration and maximum heat transfer. Accuracry is _+1% around the entire dial range. Dial is protected by extra heavy glass crystal Stern should be immersed at least 2 inches in liquid and 4 inches in gases. Length of stem is 2 ~/2 inches including threads, not suitable for gases. Cat, Temperatur~ NO~ : : Range,° Subtly s ons;? Each 14-5432-02 -40 to t60F 2 14-5452-03 25 to 125F 1 14-5432-04 0 to 220F 2 14-5432-06 50 to 300F 2 14-5432-07 50 to 400F 5 14-5432-08 50 to 500F 5 14-5482-09 150 to 750F tO 14-5432-10 *200 to IO00F 10 14-5432-12 0 te 50C 0.5 14-5432-15 -10 to ltOC 1 14-5482-16 0 to 150C 1 14-5482-18 0 to 300C 5 *Not recommended for continuous use above 8OO°F 68,22 68.22 68.22 68.22 68.22 68.22 68.22 68,22 68,22 68.22 68.22 68.22 Similar to 14-5432, except with 4 inch stem. Length of stem is 4 inches including threads. Stern should be immersed at least 2 inches in liquid and 4 inches in gases. : Temperaure Range,~ : : : :SubdivisionS/' 14-5483-02 -40 to 160F 2 14-5433-03 25 to t25F t 14-5433-04 0 to 220F 2 14-5433-06 50 to 300F 2 14-5433-07 50 to 400F 5 14-5453-08 50 to 500F 5 14-5433-09 150 to 750F 10 14-5438-10 *200 to 1000F 10 14-5433-12 0 to 50C 0.5 14-5483-15 -10 to ttOC 1 14-5433-16 0 to 150C 1 14-5433-18 0 te 30OC 5 *Not recommended for continuous use above 800°F Similar to 14-5432 excem wltn 6-inch stem. Length of stem is 6 riches including [nraaas. Stem should be immersed at least 2 inches in ilaUlO and 4 inches in gases. Cat. Temperature No. Range,° Subdivisions, ° Each 14-5434-02 -40 to 160F 2 63.22 14-5434-58 25 to 125F 1 68.22 14-5434-04 0 to 220F 2 68.22 14-5434-06 50 to 300F 2 68.22 14-5484-07 50 to 400F 5 68.22 14-5434-08 50 to 500F 5 68.22 14-5434-09 150 to 750F 10 68.22 14-5484-10 *200 to IO00F t0 68.22 14-5434-12 0 to 50C 0.5 68.22 14-5434-15 -10 to 110C t 68.22 14-5434-16 0 to 150C 1 68.22 14-5434-15 0 to 3000 5 63.22 Notes: * Not recommended for continuous use above 800°E K~... lh.~J THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, SACK-CONNECTED, 9 I N C H STEM Similar to 14-5432, except with 9 inch stem. Length of stem is 9 inches including threads. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. Cat, NO. 14-5435-02 14-5435-03 14-5485-04 14-5435-06 14-5435-07 14-5435-08 14-5435-09 14-5435-10 14-5435-12 14-5435-15 14-5435-16 14-5485-18 Temperature Range,Q - Each Subdivisions,° -40 to 160F 2 68.22 25 to 125F 1 68,22 0 to 200F 2 68.22 50 to 300F 2 65.22 50 to 400F 5 68.22 50 to 500F 5 68.22 150 to 750F 10 68,22 *200 to IO00F tO 58.22 0 to 50C 0.5 65.22 - 10 to tlOC 1 68.22 0 to 150C 1 68.22 0 to 300C 5 68.22 Notes: *Not recommended for continuous use above 80O°E THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 12 I N C H STEM THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 4 I N C H STEM Cat; NO THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H DIAL, BACK-CONNECTED, 6 I N C H STEM Each 68.22 83.22 68.22 68.22 68.22 58.22 68.22 68.22 65.22 68.22 68.22 68.22 Similar to 14-5432 except with 12-inch stem. Length of stem is 12 inches including threads. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. Cat. N~. Temperature Range,° Subdivisions, ° Each 14-5436-02 -40 to 160F 2 75,48 14-5436-03 25 to t25F t 75.43 14-5436-04 0 to 220F 2 75.43 14-5436-06 50 to 300F 2 75.43 14-5436-07 50 to 400F 5 75.43 14-5436-00 50 to 500F 5 75.43 14-5436-09 150 to 750F tO 75.43 14-5436-10 *200 to tOOOF 10 75.43 14-5436-12 0 to 50C 0,5 75.43 14-5486-15 -tO to 110C 1 75.43 14-5436-16 0 to 156C 1 75.43 14-5436-13 0 to 3000 5 75.43 Notes: *Not recommended tor continuous use above 800°E 1157 THERMOMETERS 00 Ul DIAL-TYPE LABORATORY THERMOMETERS 14-5550 14-5555-01 14-5555-12 THERMOMETERS - LABORATORY, 1 3/4 I N C H O . D . HEAD, 8 INCH SPIKE STEM, BI-METALLIC These bi-metallic laboratory dial thermometers have a 1 3/4 inch dial and an 8 inch pointed stem. Feature sturdy stainless steel construction and super sensitive bi-metal silicone treated coil for fast response. Anti-parallax dial has large, easy-to-read numbers with raised graduations. Crystal is made of clear lexan plastic. Single scale in either °F or °C. Can be easily recalibrated with hex screw. Accuracy is 1% over the entire range. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. :Tempera~re : 14-6555-01 14-5555-82 14-5556-03 14-5555-04 14-5555-06 14-5555-06 14-5555-87 14-5555-08 14-6556-09 14-5555-10 14-5555-11 14-5555-12 14-5555-13 14-5555-14 14-5555-15 14-5555-16 14-5685-17 -100 to IOOF 25 to 125F -40 to 160F O to 18OF O to 220F O to 14OF 50 to 306F 50 to 4OOF 60 to 500F 20 to 240F 50 to 250F -50 to IOOC -10 to 110C O to 1OOC O to 150C O to 250C O to 60C 2 1 2 2 2 2 2 5 5 2 2 1 t 1 1 2 0.5 20.05 20.05 20.05 20.05 20.05 20.05 20.65 20.05 20,05 20.05 20,05 20.05 20.85 20.05 20.05 20.05 20.05 THERMOMETERS - POCKET DIAL, 1 I N C H O . D . HEAD, BI-METALLIC Bi-metallic, pocket thermometers with one inch dial and 5 inch pointed stem feature stainless steel construction. Super sensitive bi-metal silicone treated coil for fast response. Anti-parallax dial has large, easy-to-read numbers with raised graduations. Crystal is made of clear lexan plastic, Accurracy is 1% over the entire range. Supplied with a plastic carrying case, which has attached pocket clip. Case can be used as a handle. Cat. No! 14-5550-01 14-5650-02 14-5558-63 14-5550-04 14-5550-05 14-5550-06 14-5550-07 14-5550-08 14-5550-09 " TemperalJre Range,° -40 to 16OF 25 to 125F 0 to 2OOF 50 to 500F O to 156C O to 250C -40 to 70C -10 to 110C -40 to 120F Subdivisions, ~ 2 1 2 5 1 2 t t 2 Each 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 17.22 DIGITAL THERMOMETERS THERMOMETERS - LABORATORY, 2 I N C H O . D . HEAD, 8 I N C H SPIKE STEM, BI-METALLIC Similar to 14-5555 except has a 2 inch diameter dial. Can be easily calibrated with hex screw. Includes 8 inch spike stem. Accuracy is 1% over the entire range. Stem should be immersed at least 2 inches in liquid and 4 inches in gases. : Temperaere 14-5580-01 14-5530-02 14-5530-03 14-5530-04 14-5530-05 14-5536-06 14-5530-07 14-5830-08 14-5530-09 14-5538-11 14-8830-12 14-5530-13 14-5530-14 14-8630-15 14-5530-16 1158 -100 to lOOF 25 to 125F -40 to 16OF 0 to 180F O to 220F 50 to 250F 50 to 30OF 50 to 40OF 50 to 500F 0 to 50C -50 to IOOC -10 to 110C 0 to tOOC 0 to 150C O to 250C . . . . . . 2 1 2 2 2 2 2 5 5 0.5 t 1 1 1 2 22-2967 DIGITAL POCKET THERMOMETER 28.56 28.56 26.56 26.56 28.56 28.56 28.56 28.86 28.66 28.56 28.56 28.56 28.66 28.56 Flat style digital pocket test thermometer originated as standard (not an adaptation of other models). For use where conventional bimetal pocket thermometers have been used. it will cover the range of-40 to 450°F with an accuracy of ±2°F (for -4 to 77°F) or ±4°F maximum over entire range; has a resolution of O.I°E Large 0.25 inch high oblong LC0 readout is easier to read than normal glass tbermometers. With instant update button and automatic shut-off. Features a 5 inch stainless steel stern for immersion. With red protective sheath and pocket clip. Lifetime warranty. Cat; : Na~ Des~iption |ach 28.56 22-2967-11 Digital Pocket Thermometer 29.50 THERMOMETERS UI 22-3004 22-3002 THERMOMETERS - DIGITAL, POCKET, TRACEABLE Lightweight thermometer with flat-profile design and built-in clip make it ideal to carry in shirt pocket, Operating range is from -50 to 572°F and 50 to 300°0 with resolution of 0.10 from -20 to 200°0 (1° otherwise) and accuracy of +-1.5°C.A hold button freezes a reading for later use and another button switches from °F to °C. Large, bright LCD is r/4 inch high and readings are updated every second. Operates continuously for 11/2 years on a single replaceable silver-oxide battery. Stern length is 3 r/e inches, stem diameter is 0.14 inch, overall length is 7 inches and weight is 1 ounce. Supplied with protective probe guard case and certificate traceable to NI.STstandard. 22-3004-01 Pocket Thermometer 26.82 THERMOMETERS - DIGITAL, DIAL, TRACEABLE Ideal for use in soil, cuvettes, food products and incubators. Choice of °F or °C models with wide temperature ranges of -67 to 300°F or -55 to 149°C. Resolution of 0.1 ° and accuracy -.1°. Large, bright LCD display is 3/e inch high and readings are updated every 10 seconds. Stem length is 4 3/4 inches, stem diameter is 1/8 inch and dial diameter is 1 1/2 inches in diameter, Operates for 1 V2 years on a single silver-oxide battery. Supplied with protective case, battery, and certificate traceable to NIST standard. Ca~? .... 22-3062-01 22-3002-02 : • Digital Thermometeb -67 to 3OO°F DigitalThermometer, 55 to 149°C 21.74 21.74 '\ 22-3001 THERMOMETERS - L O N G - S T E M , DIGITAL, TRACEABLE Long-stern thermometer fits into flasks, cuvettes, test tubes, and beakers. Stainless steel probe is resistant to acids, bases, solvents and most laboratory chemicals, Long stem allows user to make measurements while stirring solutions. Also suitable for reading temperature in foods, gases, samples, and semi-solids. Temperature range is -58 to 482°F and -50 to 250% with resolution of 0.1 ° from -20 to 200 ° and 1° outside of this range. Accuracy is _+0.2% between -20 and 100%. Reading are updated every second. Brilliant LCO display is V4 inch high. Stainless steel stern is 8 inches long and 1/8 inch diameter. Overall length is 11 inches. Supplied with 1 year battery and certificate traceable to NIST standard. Cat tfo. 22-3001-01 Long-Sterm Thermometer 28.15 21-2644 TEMPERATURE METER - PORTABLE, BATI'ERY OPERATED, M O D E L T M P 5 0 , C O R N I N G ~ The Model TMP50 is a microprocessor based handheld meter that accurately measures temperature in liquids, solids, and gases. Features one button operation, LCD readout, K-type thermocouple and housing, which is water and chemical resistant. Operating temperature range from -40 to 550°C with resolution of 1°C and accuracy _+2°C. Approximately 700 hours of operating battery life. Overall dimensions are 7.3 x 1 .B x 0.9 inches. Supplied with general purpose probe, battery and operating instructions. Optional probes available for air, surface, and penetration applications. cat.!: : Ce~.ni#g: : i NO :: 21-2644-02 21-2644-85 21-2644-66 21-2644-67 21-2644-08 DesCrlption: ' 475843 476452 476449 476450 476451 TemperatureMeter GeneralPurpose Probe Surface Probe Air Probe PenetrationProbe ; Each 67.58 30.45 30.45 30.45 30.45 1159 THERMOMETERS O I-m 22-3006 THERMOMETERS - DIGITAL, DIAL, JUMBO DISPLAY, TRACEABLE Smooth, stainless steel probe is resistant to acids, bases, solvents, and most laboratory chemicals. Provides continuous monitoring for over a year. Includes on/off power switch and switch to change between °F and °C. Operating temperature range is -58 to 302°F and -50 to tSO°C with resolution of O.f ° from -20 to 200 ° and 1° outside of this range. Accuracy is ±1°C between -20 and lOg°C. Extra large, bright LCD display is 0.4 inch high and readings are updated every second. Stem length is 5 r/4 inches, stem diameter is 1/8 inches, top diameter is 2 1/8 inches, overall length is 6 r/2 inches and weight is 1 ounce. Supplied with replaceable silver-oxide battery and certificate traceable to NIST standard. Cat;i : No~ ~; Description Each 22-3006-01 Junrbo Display Dial Thermometer 30.24 22-3008 THERMOMETERS - DIGITAL, FULL-SCALE, TRACEABLE Full-scale thermometer has large display, wide temperature range, stainless steel probe and long cable. Operating temperature range is -58 to 50O°F and -50 to 250°C with 0.1 ° resoJution from -20 to 200 ° and 1° otherwise. Accuracy is 1°C between -20 and tO0°C. Extralarge, bright LCD display is 0.4 inch high and readings are updated every second. Thermometer has flip-open easel stand, spring clip and magnetic back. Probe length is 5 ~rh6 inches, probe diameter is ~/8 inch, face diameter is 2 V8 inches, cable length is 10 feet and total weight is 3 ounces. Silver-oxide battery operates continuously for 1 V2 years. Supplied complete with display, probe, cable, battery and certificate traceable to NIST standard. Cat, No, Description Each 22-3008-01 Full Scale Thermometer 35.92 22-3010 22-3003 THERMOMETERS - BIG-DIGIT, DUAL DISPLAY, MINIMUM/MAXIMUM MEMORY, TRACEABLE Big-Digit Thermometer offers easy to read temperatures from across the lab. Dual displays permit reading ambient and probe temperatures simultaneously, Minimum/maximum memory reading may be displayed or reset at the touch of a button. Temperature range of ambient sensor, located inside of thermometer housing, is 23 to 122°F end -5 to 50°C. The external temperature probe with a 1g-foot cable has an operating range of -58 to 158°F and -50 to 70°C. Temperature resolution is O.t ° end accuracy is -+1°C. Minimum/maximum memory feature permits storing temperature records overnight, on weekends or for longer time periods. Unit is equipped with flip-open stand, a slot for wall mounting and a Velcro TM mounting strip. Battery runs continuously for 1 year. Housing is high-impact, chemical resistant ASS plastic with dimensions of 2 3/4 x 4 ~/4 x 3/4 inches and weight is 4 ounces. Supplied with AAA battery and certificate traceable to NIST. 22-3010-01 1160 Desctiption Big-Digit Thermometer Each 30.77 THERMOMETERS - DIGITAL, SENTRY HIGH/LOW, MEMORY, TRACEABLE The Sentry High/Low Thermometer has a triple display, which simultaneously shows high, low and current temperatures. Choice of °F or °C models with temperature ranges of -58 to 158°F or-5O to 70°C with resolution and accuracy of 1°. Sensor with 1g-foot cable may be placed under water, in a refrigerator or in a freezer. Smag ~h6 inch diameter cable allows refrigerator door to close. Simple one-button operation resets the high/low memories. Operates continuously for one year on supplied battery and includes low battery indicator. High impact ASS plastic housing with flip stand, hanging hook and magnetic back. Size is 2 5/8x 2 1/2x 3/4 inches and weight is 1.7 ounces. Supplied with battery and certificate traceable to NIST standard. Cat. No. Description Each 22-3003-01 High/Low Thermometer, °F 31.42 22-3003-02 High/Low Thermometer, °C 31.42 22-3003-11 Replacement Probe 20.32 22-3003-12 AccessoryStainless Steel Probe 59.27 THERMOMETERS 22-3009 THERMOMETERS TRACEABLE - DIGITAL, REFRIGERATOR/FREEZER, Accurately monitors temperatures in refrigerators, freezers,water baths and incubators with the enclosed "temperature buffered" sensor. Small sealed bottle filled with glycol solution holds sensor and insulates against rapid temperature changes when doors are opened. Triple display simultaneously shows high, low and current temperatures. Minimum/ maximum display monitors readings overnight, on weekends or for other periods of time. Alarm sounds when temperature rises above or falls below set points. Alarm is programmable in 1° increments. Visual and audible alarm signals continue for 12 hours even if temperature returns to non-alarm range. Operating temperature range is -58 to 158°F and -50 to 700C with resolution of 1° and accuracy of +_10C.Tenfoot microcable permits refrigerator door to close. VelcroTM and magnetic strips are provided for mounting of both thermometer and bottle sensor. High-impact, chemical resistant ABS housing is 2 3/4 x 4 V4 x 3/4 inches and weighs 4 ounces. Supplied with AA battery for one-year continuous operation and certificate traceable to NIST standard. C o t ; : H~ : :i 22-3005-01 OescrlptiOU i : : Refrigerator/Freezer Thermometer Each 36,91 22-3009 THERMOMETERS TRACEABLE - DIGITAL, HIGH/LOW 22-3009-01 22-3009-11 22-3009-12 22-3009-13 22-3009-14 22o3009-16 22-3009-17 :: 22-3007-01 DIGITAL Each High/Low Alarm Thermometer 43.99 COMPACT, Description :iech Digital Thermometer Replacement Probe Accessory Micro Probe AccessorySurface Probe AccessoryAir/Gas Probe Nylon Carrying Case AC Adapter, 120V 399.00 51.32 86.61 119.64 85.10 14.70 30.77 22-2969-01 ALARM, This thermometer is ideal for use in foods, soils, cuvettes, water baths, and incubators. Both a high and low alarm may be programmed in 1° increments. When temperature rises or falls below sot points, a 1 minute audible alarm signals an out-of-range situation. Alarm automatically resets itself when temperature returns to within set points. Alarm mode may be switched off when not required. Operating temperature range is -58 to 500.8°F and -50 to 2600Cwith resolution of 0.1° and accuracy of +_1°C.Switch from °F to °C or set high/low alarms. Digital display is 1 1/2 inches high and can be read from 10 feet. Stainless steel probe is 71/4 inches long, 1/8 inch diameter, with 3 foot cable and probe clip for handy storage. Single battery runs continuously for 1 year. Supplied with probe, AAA battery, and certificate traceable to NIST standard. cat,: PORTABLE, Ideal for routine temperature measurements in soil, foods, cuvettes, gas systems, water baths, and semi-solids. Operating temperature range is 40 to 3OO°Fand -40 to 150°C with resolution of 0.1" and accuracy of _+0.2°C. Large, bright LCD display is V2 inch high and readings are updated three times per second. Displays°F or °C at the push of a button. Membrane keys offer a splash proof design. Universal stainless steel probe is 61/4 inches long, probe diameter is ~/8 inch and cable is 5 feet. Size is 3 1/2 x 5 1/2 x 1 ~/4 inches and weight is 8 ounces. Supplied with probe, 9-volt battery and certificate traceable to NIST. 22-3007 THERMOMETERS TRACEABLE - DIGITAL, 22-2968-02 THERMOMETERS Model TM-gA is a portable lightweight thermometer with a sealed membrane touch pad. Will read in both °F and °C with an accuracy of +_0.2°For °C or ±0.2% of reading, whichever is greater (32 to 120°F). Temperature range is -40°F to +3gg°F with a resolution of 0.1°F or °C, and an accuracy of ±B.2°F from -40 to +100°F; _+0.2%from 100 to 300°E Operational status is indicated on display. Constructed of high impact resistant material making it perfect for field use. With 4 digit, 0.4 inch high backlighted LCD. Model TG-100A has the same specifications, plus is rechargeable. Includes hard carrying case, probe holder, rechargeable Nicad battery and recharger. Cat; NO~ : : : Description 22-2966-01 TC-100A Digitat Rechargeable Thermometer Portable, w/Case 22-2988-82 TM-99A Digital Thermometer Portable, w/Case Each 246.75 264.76 1161 THERMOMETERS Ilam 22-2980 DIGITAL THERMOMETER - TYPE K THERMOCOUPLE, BARNANT 22-2982 DIGITAL THERMOMETERS - TYPE J, K, OR T THERMOCOUPLE, B A R N A N T Portable, battery operated meter has a rugged housing and large ~/2 These easy-to-use meters are ideal for basic temperature monitoring inch digital display with hold function to display °F or °C. Accepts all applications. Meters are available for J, K, or T type thermocouples. type K thermocouple probes with ANSI miniconnectors. Field CAL Type K thermocouples are the most popular and offer a temperature allows user to calibrate out error factor of individual probe. range of -418 to 2501°F (-250 to 1372°C). Type J thermocouples SPECIFICATIONS: are rugged and reliable with a temperature range of -328 to t832°F Temperature Range: -50 to 1999°F (-50 to 1300°C) (-200 to IOOO"C). Type T thermocouples have the narrowest range Resolution: 0.1 from -50 to 199.9; but are ideal for low temperature applications with a range of -418 to Auto ranging to 1 above 199.9 752°F (-250 to 400°C). The four button keypad is easy to operate Accuracy: ±5% of reading or ±1°C and includes on/off, C/F for °C or °F, hold and CAL. The CAL button is whichever is greater a "capture" mode for a single (ice) point field calibration offset. Field Display: 31/2 Digit LCD, 1/2" High calibration lockout feature prevents tampering and protects factory Power: One 9V Battery (Supplied) settings. Housing is ABS/Polycarbonate impact resistant case with Battery Life: t20 Hours continous operation sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for Dimensions: 3"W x 6.5"H x I"D Shipping Weight: 2.01bs. splash and dust resistance. One year manufacturer's warranty. Supplied with battery and SPECIFICATIONS: Accuracy: -+O.9°F (-+B.5°C) above g9°; _+2°F(zl°C) instructions. Order Type K probe separately, see 22-2988, Below 99° plus _+0.2% of reading Resolution: 0.1 ° between -99.9 ° and 299.9°; 1° below 99.9° Display: 3 3/4 Digit LCD, 1/2' High 22-2980-01 6OO-OOO0 Type K Thermometer 95.00 Power: Two AA Batteries (Supplied) Battery Life: 500 Hours minimum: Low Battery Indicator Dimensions: 3.3'W x 6.2'H x f.2"D Shinning Weight: O.71bs Three year manufacturer's warranty. UL. cUL and CE certif .'c Sunnlied with naperies instructions and certificate of conformance. Order prone seoarateb, see 22-2988 Cat. Bernant No. No. gescriptla~ Each 22-2982-01 60D-1000 Type J Thermomezer 130.00 22-2982-02 600-1010 Type K Thermomezer 130 O0 22-2982-03 600-1020 Type T Thermometer 130.00 SEE OUR CHROMATOGRAPHY SELECTION Chromatography Paper, Columns, Ferrules, Injection Port Liners, Septa, Sorbents, Sprayers, TLC Plates, Tanks, Vials 1162 SEE OUR SELECTION OF SIEVE SHAKERS ATM, CSC, W.S. Tyler THERMOMETERS ........ ,) 22-2986 22-2984 DIGITAL THERMOMETERS - DUAL INPUT J-T-E-K THERMOCOUPLE, B A R N A N T DIGITAL THERMOMETER A N D DATA LOGGER DUALOGR, THERMOCOUPLE, B A R N A N T This meter accepts up to two thermocouple inputs and either J,K,T, or E thermocouples. Manually stores up to 25 readings in non-volatile memory. Features three 4-digit LCD displays and 12 button keypad for simplified set up and operation. Functions include on/ off, hold, calibration, °C/°F, J-T-E-K, maximum, minimum, differential and store. Two point field calibration feature for offset and slope. User can calibrate probe to known temperatures. Meter automatically stores and adjusts for inherent probe error enabling unparalleled system accuracy. Calibration lock out protects NIST traceable factory settings and prevents tampering with field calibration values. Housing is ABS/ polycarbonate impact resistant case with sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for splash and dust resistance. The DuaLogR is a dual input portable thermometer and data logger, which can manually store or automatically log up to 1000 sets of readings in real time. Log interval is selectable from 1 second to 60 minutes. Data can be directly downloaded to the optional infrared printer or to a computer with the optional RS232 interface adapter. Meter accepts up to two thermocouple inputs, which can be selected from the following types: J, K, T, E, R, S, N or B. Temperatures can be displayed in °F, °C, °R, or °K scales. Resolution and input filtering are selectable to improve readability during rapidly changing temperatures. Features three 4-digit LCD displays and 12 button keypad for easy operation. Capable of displaying minimum, maximum, and differential readings simultaneously using one or two probes on selectable, easy-to-read, muOi-data LCD. Two point field calibration feature for offset and slope. User can calibrate the probe to one or two known temperatures. Meter automatically stores and adjusts for inherent probe error enabling unparalleled system accuracy. Calibration feature protects NIST traceable factory settings and prevents tampering with field calibration values, Housing is ABS/polycarbonate impact resistant case with sealed silicone rubber keypad and built-in tilt stand. Rated IP54 for splash and dust resistance. SPECIFICATIONS: J: -328 to 1832% (-200 to IOOO°C) T: -418 to 752°F (-250 to 4OO°C) E: -418 to 1832°F (-250 to 1000°8) K: -418 to 2501°F (-250 te 1372°C) Accuracy: ±O.7°F (±O.4°C) above -238°F (-150°C); ±2°F (±t°C) Below -238°F (-150°C); plus ±0.1% of reading Resolution: 0.1 ° at or below 999.9°; 1° greater 999.9° Display: Three 4-Digit LCD Displays, 0.4" and 0.2" High Power: Two AA Batteries (Supplied) Battery Life: 500 Hours minimum; Low Battery Indicator Dimensions: 3.3W" x 6.2"H x 1.2"D Shipping Weight: O.71bs Three year manufacturer's warranty. UL, cUL and CE certified. SupI~lied with batteries, instructions, and certificate of conformance. Order probe separately, see 22-2988. Temperature Ranges: Cat No~ 22-2984-01 Bamant No. 600-1040 : Descrlption Dual J-T-E-K Thermometer SEE OUR SELECTION OF SYRINGE FILTERS Osmonics, Pall, Whatman : EaCh 185.00 SPECIFICATIONS: J: -328 to 1832°F (-200 to 1000°C) K: -418 to 2501°F (-250 to 1372°C) T: -418 to 752°F (-250 to 400°C) E: -418 to 1832°F (-250 to IOOO°C) R: 32 to 3241°F (0 to 1768°C) S: -418 to 2372°F (0 to 1768°C) N: -418 to 2372°F (-250 to 1300°C) B: 392 to 3272°P (200 to 18go°c) Accuracy: Type 5, K, T, E and N: +0.7°F (±0.4°C) Above -238°F (-150°C) ±2°F (-+1°C) Below -238°F (-150°C); plus ±0.1% of reading Resolution: 0.1 ° less than or equal to 999.9°; 1° greater than 999.9° Display: Three 4-Digit LCD Displays, 6.4' and 0.2' High Power Two AA Batteries (Supplied) Battery Life: 500 hours minimum, Low Battery indicator Dimensions: 3.3'W x 6.2'H x 1.2'D2 Shipping Weigh1 0.71bs. Three ~ear manufacturer's warranty. UL, cUL and CE certified. Supsued wlm oatrenes, instructions, and certificate of conformance. Oraer erode seoaretw, see 22-2988. Temperature Ranges: Cat, No. 22-2986-01 Barnnt No. Descriplien 600-1050 Thermometer/Data Logger Eech 240.00 1163 THERMOMETERS . . . . . . . . . . . . . . . . . - - - • .... i t • 22-2988-01 i = . ....... ¸ 22-2988-11 22-2988-41 THERMOCOUPLE PROBES - INTERGRAL HANDLE, BARNANT Thermocouple Probes for use with Barnant Digital Thermometers and DualLogR thermometer/data logger. Can also be used with any thermocouple thermometer that accepts miniconnectors. Supplied with 5-foot coiled cables with PVC/PVCinsulation and miniconnectors. Cable are ANSI color coded for easy identification: Type J cables are black, Type K are yellow, Type T are blue, and Type E are purple. Intergral probe handle is 5 1/e inches long glass-filled nylon. Choice of probes includes: general purpose, Teflon® coated general purpose, air/gas, surface and penetration. General Purpose Probes 22-2988-01 601-1000 22-2988-02 601-0000 22-2988-03 601-2000 22-2988-04 601-3000 Teflon® Coated General Purpose Probes 22-2988.11 685-1757 22-2988-12 685-1657 22-2998-13 685-0057 22-2988-14 685-1257 Air/Gas Probes 22-2988-21 604-1000 22-2988-22 604-0000 22-2988-23 604-2000 22-2988-24 604-3000 Surface Probes 22-2988-31 602-1000 22-2988-32 602-0000 22-2988-33 602-2000 22-2988-34 602-3000 Penetration Probes 22-2988-41 603-1000 22-2988-42 603-0000 22-2988-43 603-2000 22-2988-44 603-3000 Maximum : Temperature Prabe Length,in Each J K T E 1400°F (760°C) 1652°F (900%) 550 °F (288°C) 1600°F (871°C) 4 15/16 4 15/16 4 15/16 4 15146 36.75 36.75 40.95 42.00 J K T E 302°F 302°F 302°F 302 °F (150%) (150°C) (150°C) (150°C) 10 1O 10 10 57.75 57.75 57.75 59.85 J K T E 572"F 572 °F 572°F 572°F (300°C) (30O°C) (3go°c) (3OO°C) 8 1/e 8 1/e 81/8 8 1/8 48,30 48.30 48.30 58.80 J K T E 1200°F (649°6) 1200°F (649°C) 650 °F (343°C) 1200°F (649°C) 9 15/16 9 15/16 915/~e 915he 55.05 56.65 55.65 68.25 J K T E t4OO°F (760%) 1652°F (9OO°C) 550°F (288%) 1600% (871°C) 4 4 4 4 39.90 39.90 39.90 44.10 / 22-2986, 22-2987 21-2649 ACCESSORIES - FOR 22-2986, DUALOGR, THERMOMETER AND DATA LOGGER, BARNANT TEMPERATURE METER - PORTABLE, BATTERY OPERATED, MODEL 309, CORNINGo Accessories for DuaLogR thermometer and Data Logger. The infrared printer is ideal for on-site documentation. Data is transferred by infrared output, no cable to connect, just line up data transmission LED located on top of instrument and position printer within 18 inches. Print readings in real time from every three seconds to every 60 seconds or automatically print previously stored data. Printer supplied with one roll of paper. Optional printer power adapter 110-240V, 50-6gHz with 6-foot power cord. RS232 interface adapter connects data logger to computer with 9-pin serial port for easy downloading of data. Does not include software. Optional power adapter 115VAC for for DualLogR. The Model 309 is a microprocessor based temperature measurement system that uses a thermistor type of temperature input probe. This portable, handheld unit accurately measures temperature in liquids, solids, and gases. Features include push button operation, LCD readout, temperature display in °C or °E HI/LO recall, low battery indicator, and auto off. Operating temperature range from -50 to 150°C with resolution of 0.1°C and accuracy of ± 0.4°C. Approximately lOg hours of operating battery life. Splash-proof housing with easy to use membrane keypad. Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general purpose probe, wrist strap, battery and operating instructions. Optional probes available for air and penetration applications. Cal. Coming Ne~ : No. Descrlptian Each 21-2649-02 475852 Temperature Meter 155.40 21-2649-05 476604 GeneralPurpose Probe 60.90 21-2649-07 476605 Air Probe 76.65 21-2649-08 476606 Penetration Probe 60,90 22-2987-01 22-2987-02 22-2987-08 22-2987-04 22-2987-00 1164 600-0080 600-0082 37455-71 600-0090 600-0070 Infrared Printer 235.08 PrinterAdapte5 100-240VAC 65.00 PrinterPapeE Pkg. of 6 Rolls 12.00 RS232 Inte~ace Adapter 95.00 DuaLogRAdapter, t15VAC 31.00 THERMOMETERS ..-= Ut 21-2650 TEMPERATURE METER - PORTABLE, BAI"rERY OPERATED, MODEL 3 1 0 , C O R N I N G ® The Model 310 is a microprocessor based temperature measurement system that usesa K- typethermocouple with detachableprobe handle.This portable, handhetdmeter is ideal for a wide rangeof temperature measurement applications. Features include push button operation, LCD readout, temperature display in °C or oF,HI/LOrecall, tow battery indicator, and auto off. Operatingtemperature rangefrom -50 to 950°C with resolution of 0.1°C (-50 to 150) and 1°C (>150). Temperatureaccuracy is _+0.5°C or _+0.5% (-50 to 150) and ± 1.0°C or _+0•5% (>150). Approximately100 hours of operating batterylife. Splash-proof housing with easyto use keypad. Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general purpose probe, wrist strap, battery and operating instructions. Optional probes availablefor air, surface and penetrationapplications. Cat; : N0~ Carn!0it " : N0 21-2650-02 21-2650-05 21-2650-06 21-2550-07 21-2650-08 21-2650-09 475853 476607 476610 476608 476609 470441 i : : : Descrlpt it~ :.!: TemperatureMeter General Purpose Probe Surface Probe Air Probe PenetrationProbe Probe Handle i : Each 263.12 30.57 30.45 80.45 30.45 40.05 22-3035 HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M / M A X I M U M M E M O R Y , TRACEABLE Ideal for monitoring around-the-clock and for routine measurements of relative humidity and temperature. Suitable for quality control applications. Continuously and simultaneously displays relative humidity and temperature in °E or °C with dual-recall memories. Minimum and maximum memories may be displayed or cleared at any time with the touch of a button. Environmental conditions can be monitored overnight, on weekends, or for longer time periods. Temperature range is 32° to t 22°F and 0° to 50°C with resolution and accuracy of 1° . Humidity range is from 25 to 95% with resolution of 1%RH and accuracy of _+2% in mid-range to _+4% at the extreme ends of range. East-response solid-state sensor displays changes in less than 30 seconds. Large, easy-to-view 5/8 inch high digits are updated once every second• Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and humidity in labs. Case is shock and chemical-resistant ABS plastic. Size is 2 5/e x 3 7/8x 3/e inches and weight is 2 1/2ounces. Supplied with wall mount, bench stand, solid-state sensors, switch to read °F/°C, two AAA batteries and certificate traceable to NIST. Choice of three models available. Catalog number 22-3035-01 offers digital humidity/temperature with dual minimum/maximum memories. Model 22-303502 offers digital humidity with minimum/maximum memory but without temperature. Catalog number 22-3035-03 offers digital humidity/temperature but without memories• Cat; NOi ~ . . . . . PEN - DIGITAL, Pocket pen with clip is easyto carry and is idealfor measuring humidify and temperature levels. Pen continuously and simultaneously displays both RH and °F or °C with dual-racall memories. Memory displays highest ano lowest humidity/temperatura readings observed overnight or during any time period. Easy-to-read LCD display is 1 1/2 inches high and is upoatea once every second. Pocket pen has fast-response solid-state sensors. which respondto changes in less than 30 seconds. Temperature range ~s 32° to 122°E and 0° to 59% with resolution of 0.1° and accuracy of +_1°C. Relative humidity range is 2 to 98% with resolution of 1% and accuracy of _+2%at mid-range to 4% at ends of range. Supplied with two s [ver-oxloe batteriesfor 6 month of continuous operation. Caseis high-impact, chemical resistantABS plasticwith dimensions of 5 Vex 1 x 7/8inches and weight of 1 1/2 ounces. Supplied with batteries and certificate traceable to NIST Cat. NO. " . 22-3037-01 " Descdptlon : 22-3036-01 Hygrometer/Thermometer, Min/Max Memory 22-3035-02 HygrometerOnly with Min/Max Memory 22-3035-03 Hygrometer/Thermometer without Memory 22-3037 HYGROMETER/THERMOMETER M E M O R Y , TRACEABLE i Des¢rlp0ee Each Hygrometer/Thermometer Pen 48.23 ]Each 60.59 51.67 57.77 SEE OUR SELECTION OF FILTER APPARATUS Nalge Nunc, Osmonics, Pall, Whatman 1165 THERMOMETERS 22-3036 HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M / M A X I M U M MEMORY, TRACEABLE Continuously and simultaneously displays relative humidity and temperature in °F or °C with dual-recall memories. Minimum and maximum memories may be displayedor clearedat any time with the touch of a button. Conditions can be monitored overnight, on weekend or for longer time periods. Contains ambient relativehumidity and temperaturesensors within case and externaltemperature sensor with lO-foot cable. Externaltemperature probe rangeis-58 to 158°Fand -50 to 70°C.Ambient sensorrangeis 23 to 122°Fand -5 to 50°C. Temperatureresolution is t ° and accuracyis _+1°C. Humidity rangeis 25 to 95% with resolution of 1% BA and accuracyof ±2% in the mid-range to ~ % outside of mid-range. Fast response solid-state sensors show display changes in lessthan 30 seconds. Large,easy-to-view 1 ~/8 inch high digits are updatedonce even/second. Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and humidity. Caseis shockand chemical-resistant. Sizeis 3 7/8x 4 r/4 x3/4inches and weight is 5.4 ounces. Supplied with flip-open stand, wall mount, AAA batteryand certificatetraceableto NIST 22-3036-01 Digital Hygrometer/Thermometer |.oh 56.50 22-3039 HYGROMETER/THERMOMETER - DIGITAL, TRACEABLE ideal for constantly monitoring labs, fume hoods, plant areas and storage facilities. Provides humidity and temperature readings instantly. Humidity range is 25 to 95%BH with resolution of 1% and accuracy of _+2%RH at mid-range to _+4% at ends of range. Temperature range is 32° to 122°F and 0° to 50°C with resolution of 0.1 ° and accuracy of ±1 °C. Large, easy-to-read LCD has V2 inch high digits. Modern design is housed in a rugged ABS plastic case with dimensions of 3 ~/2 x 5 x 7/8 inches and weighs 6 ounces. Single AA battery provides I 1/2 years of continuous operation. Supplied complete with screw for wall mounting, plastic stand for bench use, battery and certificate traceable to NIST. Cal. No, Description Each 22-3039-01 Digital Hygrometer/Thermometer 48.03 RECORDING THERMOMETERS WEATHER H A W K RECORDING THERMOMETER 22-3038 HYGROMETER/THERMOMETER - DIGITAL, MEMORY, TRACEABLE Unit constantlymonitorstemperature and humiditywith memorycapabilityto recall high and low readings. The instrument is always on, as there is no off switch, and makes continuous readings.Equippedwith an ambient humidity/ temperature sensor inside of the housing and an externaltsmperatureprobe with a 10 foot cable. Displaysimultaneouslyshows probetemperature,ambient temperature and ambient humidity Minimum anD maximum memory readingsmay be recalledor clearedwith the rouce of a button. Humioayrange is 25 to 95% RH with resolution of 1% and accuracyof _+2%at mid-rangeto -+4°/°at ends of range, ambient temperature range is 32" to 122°Fand O" to 50°C. ExtemaJtemperature sensor range is -58° to 158°Fand -50° to 70°C Temperature resolution is 0.1° and accurac~ is _+1"0.Bright LCD Digits are V2 inch high. Case is high-impact, Chemical resls~am ABS nlastic with dimensions of 3 V2 x 5 x 7/8inches and weight is 6 ounces.Two AA eanenes provide one year of continuous operation. Suoolled comolete with ulastlc stand, internal humidity/temperature sensor, and external zemeerature sensor with 10 foot cable, AA batteriesand certificatetraceableto N S]~ 22-0038-01 1166 Digital Hygrometer/Thermomezer 56.43 Provides a continuous record of temperature variations over a 7 day period. Accuracy is ±I°E It can be used outdoors or in the laboratory area, for example, in environmental cabinets. Dimensions are 13 x 7 x 7 inches high. The electrically driven drum revolves one complete turn in seven days. The chart, in 2° divisions, ranges from -40 ° to 120°F and has colored bands which clearly indicate the significant temperature zones for convenient reading. Complete with 40 foot capillary tubing, 3-wire cord and plug, 52 charts, ink and instructions. For operation on 110 volts, 60 Hz, AC. (:at. No. Description Each 22-2995-01 Weather Hawk Thermometer 600.00 SEE OUR SELECTION OF FUME HOODS Captair, Kewaunee, Labconco THERMOMETERS ",4 22-3080 THERMOMETERS - R E C O R D I N G , P E R M A N E N T D R Y STYLUS, PTC 22-3050 THERMOMETERS BACHARACH - R E C O R D I N G , TEMPSCRIBE, These recording thermometers have a wide range of laboratory applications such as continuous recording of temperatures in heated or refrigerated incubators, controlled temperature rooms, fermentation cabinets or similar compartments. They can also be used for meteorological recordings if suitably protected from rain, snow and direct sunlight. Each instrument consists of a hi-metallic coil which has a thermal responsiveness of 0.5°F, recording pen and chart which is turned by a sturdy spring-wound clock, all mounted in a strong plastic case which can be flush mounted, suspended or set on a level surface. Temperature chart is 4 1/2 inches in diameter. Each unit is suppiied complete with two marker pens and 100 charts. Ca No. : Temperature range onecharf Temp. ~rn dv. Time dv. : :Each 22-3050-01 22-3050-02 22-3050-05 22-3050-06 22-3050-09 22-3050-11 -30 to 120°F 7 days 5°F 3 hr, -30 to 120°F 24 hr. 5°F 15 min 40 to 10O°F 7 days 2°F 3 hn 40 to t00°F 24 hr 2°F 15 min -tO to 50°F 7 days 2% 3 hr 30 to 50°0 7 days 2°C 3 hr. RECORDER CHARTS-FOR 22-3050 Catalog suffix numbers correspond with those of the Recorders, e.g., 22-3051-01 is for 22-3050-01. Cot :N~!!i ~' i~i:~:~il ~ ~i~ : :i; ! ~ 390.02 390.02 390.02 390.02 390,02 390.02 22-3050 Pkg Qiy~Price! ~,: 22-3051-01 22-3051-02 22-3051-55 22-3051-06 22-3051-09 22-3051-11 100 100 105 100 100 100 -27.00 -27.00 - 27.00 - 27.00 - 27.00 -27.00 M A R K E R PENS - F O R TEMPSCRIBE R E C O R D I N G THERMOMETERS Two marker pens in two-compartment Mylar packet for use with 223050 Recording Thermometers. For use at -30 to +150°F; 0-100% humidity. Provide 6 months to one year continuous use. Cat; :: : N~ COoi": 22-3064-02 Red Pko : : Qty--Price i 2- 22.83 Portable unit records temperatures permanently over periods of up to 24 hours or up to 7 days, Accuracy is _+2%of full scale range. Can withstand rugged environment and rough handling. Ideal for use in refrigerators, coldrooms, dairies, drying sheds, greenhouses as well as in schools, hospitals, and offices. For wet environments or extremely high humidity, the unit can be placed in a heavy polyethylene bag or sealed container, Clock movement is spring wound. A permanent, sharp stainless steel stylus presses against a plastic coated 3 5/8 inch circular chart leaving a distinct black line against the white paper and blue temperature and time graduations. NIST certification available upon request. 100 charts are provided. Cat~ -: HO~! = Range°F/°C Tlmerahge = 22-3080-01 22-3080-02 22-3080-03 22-3080-04 22-3080-05 22-3080-06 22-3080-07 22-3050-08 22-3580-09 22-3080-10 22-3080-11 22-3080-12 22-3080-13 22-3080-14 -40 to 160°F 24 hrs. 40 to 160°F 7 days 0 to 10O°F 24 hrs. 0 to 1OO°F 7 days 20 to 220°F 24 hrs, 20 to 220°F 7 days -5 to 50°C 7 days -5 to 105% 24 hrs. -5 to 105°C 7 days -5 to 5O°C 24 hrs. 20 to t20°F 24 hrs. 20 to 120°F 7 days -30 to 7O°F 24 hrs. -30 to 70°F 7 days, 22-3080-15 -40 to 70% 24 hrs. 22-3080-16 -40 to 70°C 7 days RECORDER CHARTS-FOR 22-3080 Catalog suffix numbers correspond with those of Recorders, e.g., 22-3083-01 is for 22-3080-01. Car.; NQ~ : ~ 22-3083-01 22-3083-82 22-3083-03 22-3083-04 22-8883-05 22-3083-06 22-3083-07 22-3883-08 22-3083-09 22-3083-10 22-3083-11 22-3083-12 22-3083-13 22-3083-14 22-3083-15 22-3083-16 MOUNTING Each 504.00 504.00 504.00 504.00 504.00 504,00 504.00 504.00 504.00 504.00 504.00 504.00 504.05 504.00 504.00 504,00 22-3080 9kg Qty-Pdce 100 100 100 100 100 180 180 100 100 100 100 100 100 100 100 100 -13.50 -13.50 -13.50 - 13.50 -13.50 - 13.55 -13.50 - 13.50 -13.50 - 13.50 - 13.50 - 13.50 -18.50 - 13.50 -13.50 - 13.50 BRACKET - STAINLESS STEEL Cet, i . 22-3081-01 Description " Each Mounting Bracket 32.81 1167 THERMOMETERS -,% cO 22-3365 RELAY CONTROL - SOLID STATE, MECHANICAL, P R I N C O T688 22-3230 THERMOREGULATOR - FULL RANGE TYPE, M A G N A - S E T ~, P R I N C O Fully adjustable, rapid setting thermoregulator with an accuracy to 0.002°0. Exclusive Pdnco Magna-Set principle brings accuracy and sensitivity formerly unavailable in adjustable temperature controls. Unique design features include a variable electrode with a magnetically controlled micrometer adjustment which permits changes of 0.005°C in operating temperature and improved mercury trap (or reservoir) used in making the preliminary, rough adjustment. Controls a well agitated constant temperature bath of good design to within 0.01°C Under ideal conditions a variation as little as 0.002°C has been maintained. Overall length is 335 mm including a two-piece detachable connector and cord. Diameter of ooey iS 14 ram, A suoer sensitive relay (22-3362-11 Js recommenaea: maximum capacity is 3 milliamperes at 110 volts 60 Hz. AC. -~" 22-3230-11 DescriFtion Thermoregulazor Each 420.00 For use with laboratory thermoregulators and thermostats. Unit combines solid state and mechanical components to obtain the advantages of both. There are two input binding posts, two AC receptacles and a load indicating pilot light. A one second time delay prevents chattering. This relay controls a resistive load up to 1000 watts. It operates on 115 volts, AC and provides an activating current of 100 microamperes at 7 volts DC. Complete with a heavy-duty line cord and plug. Case measures 4 x 4 x 2 inches. Cat. No. Description 22-3365-01 Relay Control SEE OUR GLOVE SELECTION Disposable Gloves, Reusable Gloves, Chemical Resistant Gloves, Temperature Resistant Gloves 22-3362 RELAY CONTROL - SOLID STATE, PRINCO T681SS A heavy duty solid state controller for use with laoorazory mermoregulators, especially the 22-3230-1t. Controls cads frorr 25 to 1500 watts. "Percent Power" ala regulates power from O zo 100%. Provides signal current of only 6 microamoeres to tl~e thermoregulator. With twin pilot lights, controlled Ioaa aria convemence outlets and heavy duty 3-prong plug. Case measures 7 x 6 x 4 inches Ii~gh. For operation on 115 volts. AC 22-3362-11 1168 Relay Control Each 630.00 SEE OUR BALANCE SELECTION A & D Weighing, Acculab, Ohaus, Sartorius, Thermo Cahn, Troemner Each 288.75 THERMOMETERS SPECIAL-USE THERMOMETERS ...a ...a 14-5000 THERMOMETERS - "EXACT-TEMPE" ERTCO Consists of an NIST traceable, Teflon®-coated thermometer in an unbreakable plastic bottle filled with propylene glycol, ethylene glycol or vermiculite. Each thermometer has an individual serial number and has been listed against a standard calibrated at the National Institute of Standards and Technology (NIST). A certificate of accuracy is supplied with each thermometer, Velcro is affixed to each bottle permitting the thermometer to be attached to the wall or door of the instrument, reducing space and breakage problems. All thermometers are total immersion. cat Range, Length, Div., Type ~ Liquid Each No. : nslremeet : C ran. C 14-5000-01 14-6000-02 14-5000-03 14-5000-04 14-5000-05 14-5000-08 14-6000-07 14-6000-08 14-5000-09 14-500G-10 14-5000-11 14-6000-12 Ultra-low Freezer Freezer Blood Bank Refrigerator Incubator Oven Oven Freezer Refrigerator Incubator Oven Oven -90 to 20 -30 to 0 -5 to 20 -5 to 15 -18 to 50 20 to 130 35 to 200 -30 to O -5 to t5 18 to 50 20 to 130 35 to 200' 145 125 125 125 135 135 145 1 O0 125 1 go 135 145 1.0 0.5 0.5 0.5 0.5 1.0 1.0 1 .O 0.5 1 .O 1.0 1.0 Spirit Spirit Spirit Spirit Spirit Spirit Spirit Mercury Mercury Mercury Mercury Mercury PP Glycol PP Glycol Eth. Glycol Eth. Glycol Eth. Glycol Vermiculite Vermiculite PP Glycol PP Glycol Eth. Glycol Vermiculite Vermiculite 58.48 46.41 70.14 46.41 46.41 48.41 78.01 46.41 46.41 46.41 46.41 78.01 SEE OUR SELECTION OF TUBING Fluoropolymer, Latex, Norprene, Polyethylene, Polyvinyl Chloride, Polyurethane, Pure Gum Rubber, Silicone, Teflon, Tygon SEE OUR SELECTION OF PIPETTORS BD Medical, BrandTech, Eppendorf, Finnpipette, Jencons, LabBest, Oxford, Popper, Volac 1169 THERMOMETERS ~(~ 14-5930 THERt~4OMETERS - PRECISION., FOR SPECIAL APPLICATIONS, ERTCO All thermometers are serialized for the purpose of traceability and all are accurate to within NIST (NBS) tolerances. rv~ IC 1.0 1.0 1.0 10 0.5 0.5 1.0 1.0 0.1 0.1 0.5 05 1.0 1.0 1.0 1O 1.0 1.0 0.5 0.5 1.0 10 1O 1.0 1O 1.0 1.0 10 t0 1O 1.0 1.0 2.0 20 tO 10 05 SFeda :fea!utes* 1, 2 1, 2 Applkatlons incubator, Water Bath Incubator, Water Beth Incubator, Water Bath Incubator, Water Bath Incubator, Water 6aths Incubator, Water Bath Incubator, Water Bath Incubator, Water Beth Coliform Incubator Coliform Incubator Block Heater, Water Bath Block Heater, Water Bath Block Heater, Water Bath Block Heater, Water Beth Short Immersion Bath Short Immersion Bath Blood Bank, Refrigerator Blood Bank, Refrigerator Incubator, Water Bath Incubator, Water Beth Autoclave, Max. Reg Autoclave, Max. Reg Ovens, Oil Baths Ovens, Oil Baths Ovens Ovens Ovens Ovens, Oil Baths Ovens, Oil Baths Ovens, Oil Baths Ovens, Oil Bathe Ovens Vacuum Ovens Vecuum Ovens Vecuam Ovens Vacuum Ovens Enzymology 14-5930-03 20 to 100 305 76 14-5930-13 20 to 100 305 76 14-5969-64 0 to 60 250 1 O0 14-5030-14 0 to 80 250 100 14-5930-01 0 to 50 305 150 i 14-5930-11 0 to 50 305 150 1 14-5930-02 O to 70 330 150 1 14-5930-12 6 to 70 330 150 1 14-5930-05 34.5 to 46 237 76 2 14-5930-15 34.5 to 46 237 76 2 14-5929-01 25 to 57 175 35 2 14-5929-11 25 to 57 175 35 2 14-5929-02 0 to 100 225 35 14-5929-12 0 to 100 225 35 14-5928-01 O to 50 1 O0 12 14-5928-11 0 to 50 1 O0 12 14-5927-01 -5 to 20 t 52 Total 2 14-5927-11 -5 to 20 152 Total 2 14-5930-06 25-37-56 240 76 2 14-5930-16 25-37-56 240 76 2 14-5930-07 80 to 135 200 Total 14-5930-17 80 to 135 200 Total 14-5925-01 O to 300 405 125 i 14-5925-02 O to 300 455 150 1 14-5925-03 0 to 300 610 305 1 14-5925-04 0 to 200 610 305 1 14-5925-14 0 to 200 610 305 1 14-6925-05 0 to 200 280 76 1 14-5925-15 0 to 200 280 76 1 14-5925-06 0 to 200 405 125 1 14-5925-16 0 to 200 405 125 1 14-5925-07 0 to 350 455 150 1 14-5926-01 24 to 130 135 Total 14-5926-11 24 to 130 135 Total 14-5926-02 35 to 200 180 Total 14-6926-12 35 to 209 180 Total 14-5032-01 24 to 38 300 95 *Special Features: 1. Immersion enlargement on thermometer stem 2. Arrows on scale indicating critical temperature SEE OUR SELECTION OF BRUSHES Assay, Beaker, Bottle, Buret, Camel Hair, Carboy, Centrifuge Tube, Cylinder, Flask, Graduate, [mhoff Cone, Pipet, Static Master, Test Tube 1170 Teflo.® coaled No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yea No Yes No Yes No No No No Yes No Yes No Yes No No Yes No Yes No Each 44.73 52.60 32.65 40.53 31.81 39.58 39.06 46.83 68.04 75.81 43.36 51.13 42.94 50.71 42.94 50.71 25.51 33.28 33.07 40.95 52.50 60.99 38.95 46.30 62.05 62,05 69.82 38.32 38.32 42.90 49,77 62.65 35.91 43.68 36.75 44,52 74.76 THERMOMETERS THERMOMETERS - ASPHALT TESTING, THERMOMETER ONLY C=ti NO, 14-5399-01 14-5399-02 Range,°F : |=ch 50-450 50-600 50,77 26.26 d THERMOMETERS - CLINICAL, ASEPTO ®, B'D T M Accurate and dependable fever thermometer with easy-to-read blue scale. Reads in Fahrenheit. Supplied in white plastic case with Lok-ln feature. Cat; : Pkg No, ~ 9-DTMNo. Typebulb Qly- price 14-5885 THERMOMETERS - AIR I M M E R S I O N , CLEAN R O O M , PTC ® These instruments are engineered to accurately measure ambient air temperature within +_2% of full scale range. Ideally suited for temperature-controlled clean rooms, cold rooms, laboratories and large areas or volumes used in environmental testing, Three temperature ranges are available: -20°F to +160°E O°F to 250°F and O°F to 50O°E Dimensions: 2 inch diameter x height, 1 inch. An ancillary hand is available for this instrument. It is held by a magnetic clutch and will retain a maximum or minimum reading. One year warranty. NIST certification available upon request. Cal~ No, 14-5885-01 14-5885-02 14-5885-03 lu~ II Range,~: °F . . . . . . . -20 to 160% 0 to 250°F 0 to 500°F Subdlv. 2° 2° 5° With Ancillary Hand 14-5885-04 -20 te 160°F 14-5885-05 0 to 250°F 14-5885-06 0 to 500°F 2° 2° 5° ..... Each 68.25 68.25 68.25 14-4795-01 14-4795-02 524015 524025 Oral Rectal 66- 29.42 29.42 14-5935 THERMOMETERS - D E W P O I N T Totalimmersion thermometers with an overalllength of 255mm. Cat.! Noi 14-5935-91 14-5935-02 ana Re, -30 to 110 -90 to 40 Sub~ : dlv; Each 1° 1° 30.66 51.34 87.93 87.93 87.93 THERMOMETERS - ASPHALT TESTING Supplied with penetration nickel plated brass armor case. Overall length 11 inches; 5 ° divisions. Cat; Noi 14-5398-01 14-5398-02 : Thermometer Only 14-5399-01 14-5399-02 Renge~°F 50 - 450 50 - 600 Each 56.38 56.38 50 - 450 50 - 600 50.77 26.26 THERMOMETERS - ASPHALT TESTING, POCKET TYPE 100 - 450°F with epoxy coated bulb for penetration protection; 5 divisions. Complete with aluminum protective case. No. 14-5406-01 14-5400-02 Range~ F ~~ Thermometer w/Case Refil~ Only Each 44.52 35.70 14-5780 THERMOMETER - DOUBLE SCALE, I N D O O R , COMFORT METER TM, TAYLOR With permacolor tube and magnifying lens. Wood grained frame finish. Bold white numbers and graduations on a brown background. Ranges are -60 to 130°F and -50 to 55°C. Overall dimensions are 7 5/8x 2 1/4 inches. Ce|. : No; : 14-5780-01 ~ Description Double Scale Thermometer ~ Each 11.95 1171 THERMOMETERS C'q r~ 14-5850 THERMOMETERS - M A X I M U M REGISTERING, MERCURIAL, W I T H PROTECTIVE CASE 14-5840 THERMOMETER - M A X I M U M REGISTERING, TAYLOR AND MINIMUM, SELF Complete with setting magnet and improved tube fastening. With a range from 40 to 130°F in two degree divisions. High temperature is registered at top of one side and low at top of other side. Mercury filled. Dimensions are 10 V2x 2 3/sx 1 ~/4 inches. o~ : 14-5840-01 : Thermometer : Each 23.49 For general testing in applications where it is impractical to make an immediate reading. The mercury column will not recede until shaken down or reset similar to fever thermometers. Overall length is 61/2 inches. Available in fully enclosed pocket case or in open-faced armor case. Cases are anodized aluminum and provided with pocket clip. Cat. Scale SubNoi ra~e dlv. Each Complete 14-6850-11 14-6950-12 14-5650-13 14-5650-15 cat. N0. O to 220°F 50 to 3OO°F 50 to 40O°F -20 to 150°C 2° 2° 2° 1° renge Replacement Thermometer-for 14-5850 14-5855-11 O to 220°F 14-5855-12 50 to 300°F 14-5655-13 50 to 400°C 14-5359-15 -20 to 150°C 45.36 45.36 45.36 45.36 Each 37.60 37.90 37.90 37.90 14-5842 THERMOMETER - M A X I M U M REGISTERING, DUAL SCALE AND MINIMUM, SELF Ranges are -40 to 5O°C in 1° divisions; -40 to 120°F in 2° divisions. Mercury filled. Reset with the press of a button. 14-4975 14-5842-01 Thermometer MICROCHEMISTRY KITS SEE Corning, Wheaton 12-9960 TO 12-9965 ]172 75.00 THERMOMETERS - MERCURIAL, FLOATING DAIRY, FAHRENHEIT Has a transparent coating for protection against shattering on sides of vat. The coating does not interfere with reading, and in case of breakage prevents contamination by mercury and glass fragments; is not affected by action of hot milk and will have no effect on the taste or quality of the milk• Diameter is 15 mm; length is 270 mm. Cat, Range, SubNe. °F dlv.,° Eeck 14-4975-Ol 20 to 160 2 32.76 14-4975-02 20 to 220 2 34.02 THERMOMETERS Q 14-5880 THERMOMETERS - SURFACE TEMPERATURE, DUAL MAGNET, GLASS COVER, PTC ® 14-5900 THERMOMETERS - SPOT CHECK, 1 a/4 INCH DIAL, PTC~ Employs a bimetallic coil sensor which has direct contact with the surface to be measured. In response to temperature, the sensor expands or contracts causing the 1 3/4 inch dial itself to rotate. This thermometer reads temperatures of all flat surfaces such as dies, hot plates, heavy sheet metal, etc. It also reads ambient temperatures in enclosed spaces, as well as in noncorrosive liquids and gases, up to 1000°E Accuracy is _+2% of full scale. NIST certification available upon request. Cat; No. : Range, F/°C " i , 14-5900-01 14-5900-02 14-5900-03 14-5g00-04 14-5900-05 14-5900-06 14-5900-07 O to 270°F 50 to 320°F 50 to 5OO°F 50 to 1000% 10 to 160°C 10 to 260% O to 525°C S..b, : dlv. Each 2° 2° 5° 10 ° 1° 2° 5° 36.75 36.75 36.75 21.00 36.75 36.75 21.00 Designedto be used on hodzontalor ferrous non-horizontalsurfaces. Dimetallic sensor is locatedin a draft shieldand is in virtual thermal contactwith surface to be measuredgivinga relativelyquickresponsetime. Glasscovered dual magnetsurface thermometeroperates across a total rangefrom -100 to +750°Fand-70 to +400°Cwith an accuracyof ±2%. Diameteris 2 inches. Two Alnico magnetshold it securely in placeon horizontalor non-horizontal steel or ferrous metalsurfaces. NISTcertificationavailableupon request. CaI~ Na~ : 14-5880-01 14-5880-02 14-5880-03 14-5880-04 14-5880-05 14-5880-06 14-5880-07 14-5080-08 14-5880-09 14-5880-10 Range, "F/°C Subdlv, Each -100 to 160°F 0 to 150°F O to 250°F 0 to 5OO°F 50 to 750°F -70 to 70°C -15 to 65% -20 to 120°C -20 to 250°C 10 to 400% 2° 1° 2° 5° 10 ° 2° 1° 1° 2° 5° 52.44 52.44 52.44 52.44 29.95 52.44 52.44 52.44 52.44 29.95 THERMOMETERS - SPOT CHECK, I 3/4 INCH DIAL, N O N - H O R I Z O N T A L SURFACES, PTC ® Similar to 14-5900 but includes magnet and leaf spring for use on non-horizontal ferrous surfaces or for permanent mounting. NIST certification available upon request. Car : ~ " Range NO, : "Fp~ ' 14-5901-91 0 to 270% 14-5901-02 50 to 320°F 14-5901-03 50 to 5OO°F 14-5901-04 50 to IOOO°F 14-5901-05 10 to t60°C 14-5901-06 10 to 260°C 14-5901-07 0 to 525°C i THERMOMETERS - SPOT CHECK, i M A X - M I N , PTC ® Sub, ; ' diW 2° 2° 5° 10 ° 1° 2° 5° 3/4 : Each 45.51 45.51 45.51 45.51 45.51 45.51 45.51 I N C H DIAL, Similar to 14-5901 but with Max-MJn pointers to indicate lowest and highest temperatures reached during the thermometer's exposure. NIST certification available upon request. Cat. Ne~ 14-5902-01 14-5902-02 14-5902-03 14-5902-04 14-5902-06 14-5902-07 i Range, : "EpC O to 270°F 50 to 320°F 50 to 500°F 50 to IOOO°F 10 to 260°C 0 to 525°C gub.~ : dl~;i 2° 2° 5° 10 ° 2° 5° !aCK 48.98 48.98 48.98 40.08 48.98 48.98 14-5881 THERMOMETERS - SURFACE TEMPERATURE, PTC ® Thermometers are fully enclosed to protect bimetal from dirt and dust. Diameteris 2 inches. Requires either a small magnet clamp to hold it securely in place on non-horizontal steel or other ferrous metal surfaces, or heavy silicone grease which can be used to stick the thermometer to any flat surface. NIST certification available upon request. Cob No; i Range : "F/"C ~ Subi ~ ~ dlv~ : EaCh 14-5881-01 -50 to 250~F 2° 47.00 14-5881-02 -50 to 110°C 2° 47.00 14-5081-03 0 te 300°F 2° 47.00 14-5881-04 -10 to 150°C 2° 47.00 14-5801-05 70 to 370°F 2= 47.00 14-5881-06 20 to 180% 2° 47.00 MAGNET AND LEAF SPRING, FOR 14-5881 THERMOMETER Clampholdsthermometersecurely in placeon steelor otherferrous metals. Cat~ Ne~ Description : . ~ Each 14-5882-01 Magnetic Thermometer Clamp 5.00 THERMOMETER ADHESIVE-SILICONE, FOR 14-5881 THERMOMETER Silicone grease holds thermometer securely on any flat surface. Caf~ No~ 14-5983-01 Description i i Thermometer Adhesive Each 7.08 1173 THERMOMETERS 14-5903 THERMOMETERS - SURFACE, MINIATURE SPOT CHECK, PTC ® Designed to measure surface temperatures in limited space. Bimetallic sensor comes in close contact with surface to be measured, providing a very fast response time. Made of stainless steel, they are rugged and will hold calibration indefinitely unless mishandled. Dial face (3/4 inch) and graduations are fired ceramic on stainless steel. An ancillary pointer is held by a magnetic clutch and indicates the highest or lowest temperature reached in a given period. It withstands vibration and jarring of normal use and can be reset indefinitely. Ideal for testing temperatures of electronic parts as well as heat exchangers, circulating ovens, lab heaters, hot plates, etc. NIST certification available upon request. 14-5003-01 14-5963-02 14-5903-03 14-5903-04 14-5903-05 14-5903-06 : °+ 0 to 250°F 0 to 5OO°F 50 to 750°F 0 to 135°C 0 to 275°C ' 10 to 4OO°C Sub~: dr. ~ ~ 2° 5° 10 ° 5° 5° 5° hock 43.73 43.73 43.73 43.73 43.73 43.73 14-5695 THERMOMETERS - TANK, SCOOP-MASTER One piece non-sparking cup-case molded out of a smooth, black, heat and chemical resistant plastic. The cup capacity of 120 mL meets with API and ASTM requirements. The scale is engraved on the tube for greater accuracy. The permanently etched thermometer tubes are furnished in Yellow Lens tubing for easier reading. Tube is held in place by spring clips, and can be replaced without tools. Overalllength, 355 mm. Cat. No. Complete 14-5695-01 14-5605-02 14-5695-03 14-5695-04 14-5695-05 14-5695-06 14-5695-07 14-5695-08 Range, °F/oC Div., °F/°C ASTM No. Each -30 to 120°F 0 to 180°F 20 to 220°F 176 to 500°F -34 to 49°6 -18 to 82°C -7 to 105°C 77 to 260°C 1.O°F 1.0°F 1,0°F 20% 0.5°C 05°C 0,5°C 1.0°6 58F 59F 130F 60F 58C 59C 130C 60C 75.66 75.60 75,60 83.66 75.60 75.60 75.60 83.66 Cat. No. 1174 Each 21.42 21.42 25.30 34.44 21.42 21.42 25.30 34.44 BACK The 355 mm long cases are made form hardwood that is lacquered to prevent absorption of the sample. The 100 mL capacity brass cup is non-sparking. Thermometers are identical with those supplied with 14-5695 Seoopmaster, and are similarly mounted with easily maneuverable spring clips. 14-5696-01 -30 to 120°F 14-5696-02 0 to 1800F 14-5696-03 20 to 220°F 14-5696-04 170 to 500°F 14-5696-05 -34 to 49% 14-5696-06 -18 to 82°C 14-5696-07 -7 to 105% 14-5696-08 77 to 260°C Note: See 14-5700forrefills ASTM Noi Replacement Thermometers- for 14-5695 and 14-5696 14-5700-01 -30 to 120°F 58F 14-5700-02 0 to 180% 59F 14-5700-03 20 to 220°F 130F 14-5700-04 170 to 50O°F 60F 14-5700-05 -34 to 49°C 58C 14-5700-06 -18 to 82% 59C 14-5700-07 -7 to 105°0 130C 14-5700-08 77 to 260% 600 14-5696 THERMOMETERS - TANK, W O O D Range, °F/°C , ;Ely;,. F/c:, 1.0°F 1.0°F 1.0°F 2.0°F 05°C 0.5°0 0.5°C 1.0+6 RSTm ~ NO 58F 59F 130F 60F 580 59C 130C 60C + Each 70.56 70.56 70.66 79.48 70.56 70.56 70.58 79.48 14-5936 THERMOMETERS - WEATHERING TEST Precision thermometers manufactured according to specifications of the California Natural Gas Association for weathering tests of fabrics and other materials. Cat. No. 14-5936-01 14-5936-02 Range, OF 0 to 45 -70 to 0 Suhdiv., Length, Immersion, °F mm mm 0,2 0.5 395 345 37 115 Each 31.18 62.37 THERMOMETERS rIMER 22-3040 HYGROMETER/THERMOMETER - DIAL 22-3468 Provides humidity and temperature readings in an easy-to-read dJal format. Large 6-inch diameter analog face displays 0 to 100% relative humidity and temperature from -40 ° to 122°F (-40 ° to 50°C). Temperature resolution is 1° and accuracy is _+1.5%. Humidity resolution is 1%RH and accuracy is _+2.5% at 5O%RH. Ideal for constantly monitoring labs, hallways, walk-ins, storage facilities, and plant areas. Self-contained unit is stable, accurate and requires no adjustment or maintenance. Supplied complete with screw for wall mounting. Size is 6-inch diameter x 1 inch and weight is 8 ounces. Cat : 22-3040-01 : : : Each Dial Hygrnmeter/Therrnometer 71.22 CLOCKS - ELECTRIC, 2 4 H O U R , TYPE LABORATORY WALL Clock has standard 12 hour black numbered outer dial with inner ring of balance of 24 hours in red. White background. Clear plastic lens. Diameter of dial, 12 inches. Housed in slim, 2 V2 inch deep case. Available in quartz or regular 120 volts, 60 Hz, AC. UL listed. Quartz clocks require one "AA" battery (not supplied). Cat, NQ 22-3468-02 22-3468-04 Dial dia., Type Reg electric Quartz ini 12 12 Eech 44.78 55.78 ELECTRIC STOP TIMERS THERMOMETER RACKS 22-3710 14-4375 THERMOMETER T I M E R - KWIK-SET, L A B - C H R O N , RACK - POLYPROPYLENE Suitable for holding up to 25 thermometers in the correct vertical position, thus avoiding mercury separation, which often occurs when thermometers are improperly stored. Manufactured from V4 inch polypropylene, the rack is sturdy and will not tip. Sides have large comfortable carry handles. The top and middle plates have 5/~6 inch hole diameters. The bottom plate has convenient V8 inch diameter drain holes. Overall dimensions are 8 x 10 x 5 3/4 inches deep. The entire rack is steam autoclavable. Cat;: N~ 14-4875-01 : : Descr ptlod ~::~ : Thermometer Reck : :: Each, LAB-LINE Unit features a high torque, synchronous motor which assures consistent accuracy regardless of voltage fluctuations or line load. The large, illuminated timing switch requires only a light touch for operation. Pushbutton reset instantly returns all numbers to zero; electric brake. Steel housing is finished in baked enamel and measures 7 x 4 x 4 inches high. With 6 foot, 3-wire cord and plug. 15-month warranty. For operation on 120 volts, 60 Hz, AC, 30 watts, Cat. No 22-3710-D1 T merrange Dial divisiQa$ EaCh To gggg.g seconds 0.1 second 311.85 30.95 1175