THERMOMETERS - sfsi

Transcription

THERMOMETERS - sfsi
THERMOMETERS
14-4856
THERMOMETERS - CELSIUS, TEFLON ® COATED,
~; 1 0 / 3 0 , G R O U N D JOINT, YELLOW BACK,
PRECISION GRADE
14-486S
Similar to the 14-4855 series with the added feature of Teflon® coating to protect against shock as well as contamination in the event of
accidental breakage. The entire instrument is coated with Teflon, with
the exception of the ground joint. Accurate to within NIST (NBS)
tolerances.
Cet
:
:
Range::
-lO'C
::
~
75 mm Immersion
14-4856-01
14-4856-02
14-4856-03
100 mm Immersion
14-4856-04
14-4856-05
14-4856-06
125 mm Imme~ion
14-4856-07
14-4856-08
14-4856-09
150 mm Immersion
14-4856-10
14-4856-11
14-4856-12
190 mm Immersion
14-4856-13
14-4856-14
14-4856-15
215 mm Immersion
14-4856-16
14-4856-17
14-4856-18
250 mm Immerszon
14-4856-19
14-4856-20
14-4856-21
280 mm Immersion
14-4856-22
14-4856-23
14-4856-24
305 mm Immersion
14-4856-25
14-4856-26
14-4856-27
;:
(r.n
THERMOMETERS - LONG IMMERSION TYPE,
WITHOUT GROUND JOINT, YELLOW BACK
Mercury filled, yellow backed, etched stem, available in -10 to 250°C
and -10 to 360°C. Subdivisions on both ranges are 1°. Length of the
250% thermometers, exclusive of the immersion, is 11 inches; of the
360%, 12 inches. These thermometers can be used with the
thermometer adapters shown under 14-6900 to 14-6950.
;
i
:
-10 to 250°C
14-4865-22
14-4865-23
14-4865-24
14-4865-25
14-4865-26
14-4865-27
14-4865-28
14-4865-29
14-4865-30
4
5
6
7
8
g
10
11
12
41.47
43.57
45,36
47.77
48.51
50.29
51.13
55.44
56.38
-10 to 360°C
14-4866-22
14-4866-23
14-4866-24
14-4866-25
14-4866-26
14-4866-27
14-4868-28
14-4866-20
14-4866-30
4
5
5
7
8
9
10
11
12
43.57
45.04
44.70
50.92
52.71
56.17
58.90
60.16
60.16
110
150
250
45.36
48.30
52.39
110
150
250
49.14
50.40
53.13
110
150
250
50.08
58.02
55.96
110
150
250
55.96
57.22
59.43
116
150
250
59.53
61.42
64.89
110
150
250
67.72
67.72
70.56
THERMOMETERS - LOW TEMPERATURE, CELSIUS, RED
LIQUID FILLED, TOTAL IMMERSION
110
150
250
71.29
53.02
74.65
Made of solid thermometer tubing having a diameter of 6 to 7 mm
with expansion bulb and suspension ring. Liquid column is dyed red
to facilitate reading.
110
150
250
80.22
81.58
84.21
110
150
250
86.73
87.88
90.61
Renp
14-4700-01
14-4700-02
~
-100 to 50
-50 to 50
S U b - L e n g t h,
1
t
305
306
36.61
36.61
THERMOMETERS - CELSIUS, ~ 1 0 / 3 0 , GROUND
JOINT, WHITE BACK, ORGANIC FILLED, PRECISION
GRADE
Similar to the 14-4855 series but with colored spirit filling in place of
mercury.
Ca
NO.
14-4857-01
14-4857-02
14-4857-03
14-4887-04
14-4857-05
14-4857-06
14-4857-07
14-4857-08
:
;
Range,
%
-10
-10
-10
-10
-10
-10
-10
-10
to
to
to
to
to
to
to
to
110
150
110
150
110
150
110
150
Immersion,
m
76
76
100
tO0
125
125
150
150
:
Each
37.48
40.63
41.37
42.63
42.31
45.15
48.19
49.35
14-4780
THERMOMETER - LOW TEMPERATURE, CELSIUS,
ORGANIC FILLED, PRECISION GRADE
A total immersion thermometer filled with colored organic.
Approximate length is 350 mm. Range is -200 to +30°0. graduated
in 1° divisions.
cat.
:
~
:
14-4780-01
Low Temperature Thermometer
87.04
1155
THERMOMETERS
REPLACEMENT THERMOMETERS
Cat.
No.
14-4852
THERMOMETERS - TOTAL IMMERSION, YELLOW
BACK, RED LIQUID, ORGANIC FILLED, SAMA
PRECISION GRADE
Length is 305 mm. All thermometers are individually serialized.
:
i::
Sub,
Range
Each
14-4852-01
-20 to 110°C
1°C
25,09
14-4852-02
-20 to tSO°C
1%
25,09
14-4852-03
0 to 230°F
2°F
25.09
14-4852-04
0 1o 300°F
2°F
25.09
14-4852-05
35 to 50°C
1°C
08,57
14-4852-06
30 to 120°F
l°F
25.00
Range,°
Red Spirit Filled (For 14-4915)
14-4920-01
-30/120F
14-4920-02
+30/120F
14-4920-03
0/220F
14-4920-05
-35/50C
14-4020-06
-20/105C
Mercury Filled (For 14-4916)
14-4921-01
-30/120F
14-4921-02
+30/120F
14-4921-03
0/220F
14-4921-05
-35/50C
14-4021-06
-20/105C
SAFETY
25.09
25.09
25.09
27,30
25.09
25.09
25,09
25.09
14-4915
Available as red liquid filled or mercury filled. Cases are plated meta~
with pocket cJip. The metal tops in which thermometers are secured
have metal rings for suspension. Length is 165 ram, with toughened
bulb and permanent marking.
1156
~ Rng~
::
Sub-~
dlv.
:
THERMOMETERS - SAFETY, TEFLON ® COATED, YELLOW
BACK, MERCURIAL
These 76 mm immersion thermometers are sealed in an inert, transparent Teflon® jacket which absorbs shock and prevents shattering.
The jacket prevents contamination and also serves to retain the mercury and glass in case of breakage. Thermometers are 300 mm long.
All thermometers are serialized; accurate to NIST (NBS) tolerances.
Cat.
No~
Range
Sabdiv.
Each
14-4387-01
-20 to 110%
1°C
37.22
14-4387-02
-20 to 150°C
1°C
37.22
14-4387-03
-10 to 200°C
1°C
37.22
14-4387-11
60 to 260°C
1°C
42.00
14-4387-04
0 to 230°F
2°F
37.22
14-4387-05
0 to 300°F
2°F
37.22
14-4387-06
20 to 400°F
2°F
37.22
14-4387-12
140 to 500°F
2°F
42.00
THERMOMETERS - SAFETY, TEFLON ® COATED, WHITE
BACK, RED SPRIRIT FILLED
THERMOMETERS - POCKET, WITH METAL CASE
Ca
N~
Red Spirit Filled
14-4915-01
14-4915-02
14-4915-03
14-4915-05
14-4915-06
Mercury Filled
14-4916-01
14-4916-02
14-4916-03
14-4916-05
14-4916-06
17.74
17.74
17.74
17.74
17.74
14-4387
Similar to 14-4852 but 76 mm immersion. All Celsius thermometers
are in 1° divisions; all Fahrenheit thermometers are in 2 ° divisions.
Length is 305 mm.
-35 to 50°C
-20 to 110%
-20 to 150%
-10 to 200°C
-30 to 120°F
-O to 230%
0 to 300°F
20 to 400°F
17.74
17.74
17.74
17.74
17.74
THERMOMETERS
THERMOMETERS - PARTIAL IMMERSION, YELLOW
BACK, RED LIQUID, ORGANIC FILLED, SAMA
PRECISION GRADE
14-4853-01
14-4853-02
14-4853-03
14-4853-04
14-4853-05
14-4853-06
14-4883-07
14-4853-08
Each
Each
-30 to 120°F
+30 to 120°F
0 to 220°F
-35 to 50°C
-20 to 105%
2°F
l°F
2°F
1°C
1%
28.87
28,87
28.87
28.87
28.87
-30 to 120°F
+30 to 120°F
0 to 220°F
-35 to 50%
-20 to 105°C
2°F
I°F
2°F
1°C
1°C
25,41
28.87
28.87
25.41
25.41
Similar to 14-4387 except white back and red colored spirit filling.
Cat;
No.
14-4388-01
14-4388-02
14-4388-03
14-4388-04
14-4388-05
14-4388-06
14-4388-07
14-4388-08
14-4388-09
14-4388-10
Range.
-20 to 110%
-20 to 150%
-10 to 2000C
0 to 230°F
0 to 300°F
20 to 400°F
-50 to 50°C
-100 to 50%
-50 to 50°C
-100 to 5g°c
Subdi~
1°C
1°C
1%
2°F
2°F
2°F
t°C
1°C
1°C
t°C
Lenghl Immersian
nun
mm
Each
300
76
37.22
300
76
37.22
305
75
37.22
300
76
37.22
300
76
37.22
305
76
37.22
305
76
38.95
305
76
87.85
305
Total
38.95
305
Total
57.85
THERMOMETERS
DIAL-TYPE INDUSTRIAL THERMOMETERS
T
14-5432
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 2 1/2 INCH STEM
Industrial grade back-connected bE-metallic 3 inch diameter dial is ideal
for many applicatLons. Can be easily recalibrated with hex screw. Made
o1 18-8 type 304 stainless steel with all welded construction. Stern
diameter is r/4 with V2 inch NPT connection nut. Single scale in either
°F or %. Actuated by super-sensitive bE-metallic helix coil.
Bi-metallic element is dampened with silicone for minimum pointer
vibration and maximum heat transfer. Accuracry is _+1% around the
entire dial range. Dial is protected by extra heavy glass crystal Stern
should be immersed at least 2 inches in liquid and 4 inches in gases.
Length of stem is 2 ~/2 inches including threads, not suitable for gases.
Cat,
Temperatur~
NO~ :
:
Range,°
Subtly s ons;?
Each
14-5432-02
-40 to t60F
2
14-5452-03
25 to 125F
1
14-5432-04
0 to 220F
2
14-5432-06
50 to 300F
2
14-5432-07
50 to 400F
5
14-5432-08
50 to 500F
5
14-5482-09
150 to 750F
tO
14-5432-10
*200 to IO00F
10
14-5432-12
0 te 50C
0.5
14-5432-15
-10 to ltOC
1
14-5482-16
0 to 150C
1
14-5482-18
0 to 300C
5
*Not recommended for continuous use above 8OO°F
68,22
68.22
68.22
68.22
68.22
68.22
68.22
68,22
68,22
68.22
68.22
68.22
Similar to 14-5432, except with 4 inch stem. Length of stem is 4
inches including threads. Stern should be immersed at least 2 inches
in liquid and 4 inches in gases.
:
Temperaure
Range,~
: :
:
:SubdivisionS/'
14-5483-02
-40 to 160F
2
14-5433-03
25 to t25F
t
14-5433-04
0 to 220F
2
14-5433-06
50 to 300F
2
14-5433-07
50 to 400F
5
14-5453-08
50 to 500F
5
14-5433-09
150 to 750F
10
14-5438-10
*200 to 1000F
10
14-5433-12
0 to 50C
0.5
14-5483-15
-10 to ttOC
1
14-5433-16
0 to 150C
1
14-5433-18
0 te 30OC
5
*Not recommended for continuous use above 800°F
Similar to 14-5432 excem wltn 6-inch stem. Length of stem is 6
riches including [nraaas. Stem should be immersed at least 2 inches
in ilaUlO and 4 inches in gases.
Cat.
Temperature
No.
Range,°
Subdivisions,
°
Each
14-5434-02
-40 to 160F
2
63.22
14-5434-58
25 to 125F
1
68.22
14-5434-04
0 to 220F
2
68.22
14-5434-06
50 to 300F
2
68.22
14-5484-07
50 to 400F
5
68.22
14-5434-08
50 to 500F
5
68.22
14-5434-09
150 to 750F
10
68.22
14-5484-10
*200 to IO00F
t0
68.22
14-5434-12
0 to 50C
0.5
68.22
14-5434-15
-10 to 110C
t
68.22
14-5434-16
0 to 150C
1
68.22
14-5434-15
0 to 3000
5
63.22
Notes: * Not recommended for continuous use above 800°E
K~...
lh.~J
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, SACK-CONNECTED, 9 I N C H STEM
Similar to 14-5432, except with 9 inch stem. Length of stem is 9
inches including threads. Stem should be immersed at least 2 inches
in liquid and 4 inches in gases.
Cat,
NO.
14-5435-02
14-5435-03
14-5485-04
14-5435-06
14-5435-07
14-5435-08
14-5435-09
14-5435-10
14-5435-12
14-5435-15
14-5435-16
14-5485-18
Temperature
Range,Q -
Each
Subdivisions,°
-40 to 160F
2
68.22
25 to 125F
1
68,22
0 to 200F
2
68.22
50 to 300F
2
65.22
50 to 400F
5
68.22
50 to 500F
5
68.22
150 to 750F
10
68,22
*200 to IO00F
tO
58.22
0 to 50C
0.5
65.22
- 10 to tlOC
1
68.22
0 to 150C
1
68.22
0 to 300C
5
68.22
Notes: *Not recommended for continuous use above 80O°E
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 12 I N C H STEM
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 4 I N C H STEM
Cat;
NO
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 6 I N C H STEM
Each
68.22
83.22
68.22
68.22
68.22
58.22
68.22
68.22
65.22
68.22
68.22
68.22
Similar to 14-5432 except with 12-inch stem. Length of stem is 12
inches including threads. Stem should be immersed at least 2 inches
in liquid and 4 inches in gases.
Cat.
N~.
Temperature
Range,°
Subdivisions,
°
Each
14-5436-02
-40 to 160F
2
75,48
14-5436-03
25 to t25F
t
75.43
14-5436-04
0 to 220F
2
75.43
14-5436-06
50 to 300F
2
75.43
14-5436-07
50 to 400F
5
75.43
14-5436-00
50 to 500F
5
75.43
14-5436-09
150 to 750F
tO
75.43
14-5436-10
*200 to tOOOF
10
75.43
14-5436-12
0 to 50C
0,5
75.43
14-5486-15
-tO to 110C
1
75.43
14-5436-16
0 to 156C
1
75.43
14-5436-13
0 to 3000
5
75.43
Notes: *Not recommended tor continuous use above 800°E
1157
THERMOMETERS
00
Ul
DIAL-TYPE LABORATORY THERMOMETERS
14-5550
14-5555-01
14-5555-12
THERMOMETERS - LABORATORY, 1 3/4 I N C H O . D .
HEAD, 8 INCH SPIKE STEM, BI-METALLIC
These bi-metallic laboratory dial thermometers have a 1 3/4 inch dial
and an 8 inch pointed stem. Feature sturdy stainless steel
construction and super sensitive bi-metal silicone treated coil for fast
response. Anti-parallax dial has large, easy-to-read numbers with
raised graduations. Crystal is made of clear lexan plastic. Single scale
in either °F or °C. Can be easily recalibrated with hex screw. Accuracy
is 1% over the entire range. Stem should be immersed at least 2
inches in liquid and 4 inches in gases.
:Tempera~re :
14-6555-01
14-5555-82
14-5556-03
14-5555-04
14-5555-06
14-5555-06
14-5555-87
14-5555-08
14-6556-09
14-5555-10
14-5555-11
14-5555-12
14-5555-13
14-5555-14
14-5555-15
14-5555-16
14-5685-17
-100 to IOOF
25 to 125F
-40 to 160F
O to 18OF
O to 220F
O to 14OF
50 to 306F
50 to 4OOF
60 to 500F
20 to 240F
50 to 250F
-50 to IOOC
-10 to 110C
O to 1OOC
O to 150C
O to 250C
O to 60C
2
1
2
2
2
2
2
5
5
2
2
1
t
1
1
2
0.5
20.05
20.05
20.05
20.05
20.05
20.05
20.65
20.05
20,05
20.05
20,05
20.05
20.85
20.05
20.05
20.05
20.05
THERMOMETERS - POCKET DIAL, 1 I N C H O . D . HEAD,
BI-METALLIC
Bi-metallic, pocket thermometers with one inch dial and 5 inch pointed
stem feature stainless steel construction. Super sensitive bi-metal
silicone treated coil for fast response. Anti-parallax dial has large,
easy-to-read numbers with raised graduations. Crystal is made of
clear lexan plastic, Accurracy is 1% over the entire range. Supplied
with a plastic carrying case, which has attached pocket clip. Case can
be used as a handle.
Cat.
No!
14-5550-01
14-5650-02
14-5558-63
14-5550-04
14-5550-05
14-5550-06
14-5550-07
14-5550-08
14-5550-09
"
TemperalJre
Range,°
-40 to 16OF
25 to 125F
0 to 2OOF
50 to 500F
O to 156C
O to 250C
-40 to 70C
-10 to 110C
-40 to 120F
Subdivisions,
~
2
1
2
5
1
2
t
t
2
Each
17.22
17.22
17.22
17.22
17.22
17.22
17.22
17.22
17.22
DIGITAL THERMOMETERS
THERMOMETERS - LABORATORY, 2 I N C H O . D . HEAD,
8 I N C H SPIKE STEM, BI-METALLIC
Similar to 14-5555 except has a 2 inch diameter dial. Can be easily
calibrated with hex screw. Includes 8 inch spike stem. Accuracy is 1%
over the entire range. Stem should be immersed at least 2 inches in
liquid and 4 inches in gases.
: Temperaere
14-5580-01
14-5530-02
14-5530-03
14-5530-04
14-5530-05
14-5536-06
14-5530-07
14-5830-08
14-5530-09
14-5538-11
14-8830-12
14-5530-13
14-5530-14
14-8630-15
14-5530-16
1158
-100 to lOOF
25 to 125F
-40 to 16OF
0 to 180F
O to 220F
50 to 250F
50 to 30OF
50 to 40OF
50 to 500F
0 to 50C
-50 to IOOC
-10 to 110C
0 to tOOC
0 to 150C
O to 250C
. . . . . .
2
1
2
2
2
2
2
5
5
0.5
t
1
1
1
2
22-2967
DIGITAL POCKET THERMOMETER
28.56
28.56
26.56
26.56
28.56
28.56
28.56
28.86
28.66
28.56
28.56
28.56
28.66
28.56
Flat style digital pocket test thermometer originated as standard (not
an adaptation of other models). For use where conventional bimetal
pocket thermometers have been used. it will cover the range of-40
to 450°F with an accuracy of ±2°F (for -4 to 77°F) or ±4°F maximum
over entire range; has a resolution of O.I°E Large 0.25 inch high
oblong LC0 readout is easier to read than normal glass tbermometers. With instant update button and automatic shut-off. Features a
5 inch stainless steel stern for immersion. With red protective sheath
and pocket clip. Lifetime warranty.
Cat; :
Na~
Des~iption
|ach
28.56
22-2967-11
Digital Pocket Thermometer
29.50
THERMOMETERS
UI
22-3004
22-3002
THERMOMETERS - DIGITAL, POCKET, TRACEABLE
Lightweight thermometer with flat-profile design and built-in clip make
it ideal to carry in shirt pocket, Operating range is from -50 to 572°F
and 50 to 300°0 with resolution of 0.10 from -20 to 200°0 (1° otherwise) and accuracy of +-1.5°C.A hold button freezes a reading for later
use and another button switches from °F to °C. Large, bright LCD is
r/4 inch high and readings are updated every second.
Operates continuously for 11/2 years on a single replaceable
silver-oxide battery. Stern length is 3 r/e inches, stem diameter is 0.14
inch, overall length is 7 inches and weight is 1 ounce. Supplied with
protective probe guard case and certificate traceable to NI.STstandard.
22-3004-01
Pocket Thermometer
26.82
THERMOMETERS - DIGITAL, DIAL, TRACEABLE
Ideal for use in soil, cuvettes, food products and incubators. Choice
of °F or °C models with wide temperature ranges of -67 to 300°F or
-55 to 149°C. Resolution of 0.1 ° and accuracy -.1°. Large, bright
LCD display is 3/e inch high and readings are updated every 10
seconds. Stem length is 4 3/4 inches, stem diameter is 1/8 inch and
dial diameter is 1 1/2 inches in diameter, Operates for 1 V2 years on a
single silver-oxide battery. Supplied with protective case, battery, and
certificate traceable to NIST standard.
Ca~?
....
22-3062-01
22-3002-02
:
•
Digital Thermometeb -67 to 3OO°F
DigitalThermometer, 55 to 149°C
21.74
21.74
'\
22-3001
THERMOMETERS - L O N G - S T E M ,
DIGITAL, TRACEABLE
Long-stern thermometer fits into flasks, cuvettes, test tubes, and
beakers. Stainless steel probe is resistant to acids, bases, solvents
and most laboratory chemicals, Long stem allows user to make
measurements while stirring solutions. Also suitable for reading temperature in foods, gases, samples, and semi-solids. Temperature
range is -58 to 482°F and -50 to 250% with resolution of 0.1 ° from
-20 to 200 ° and 1° outside of this range. Accuracy is _+0.2% between
-20 and 100%. Reading are updated every second. Brilliant LCO
display is V4 inch high. Stainless steel stern is 8 inches long and 1/8
inch diameter. Overall length is 11 inches. Supplied with 1 year
battery and certificate traceable to NIST standard.
Cat
tfo.
22-3001-01
Long-Sterm Thermometer
28.15
21-2644
TEMPERATURE METER - PORTABLE, BATI'ERY
OPERATED, M O D E L T M P 5 0 , C O R N I N G ~
The Model TMP50 is a microprocessor based handheld meter that
accurately measures temperature in liquids, solids, and gases.
Features one button operation, LCD readout, K-type thermocouple
and housing, which is water and chemical resistant. Operating
temperature range from -40 to 550°C with resolution of 1°C and
accuracy _+2°C. Approximately 700 hours of operating battery life.
Overall dimensions are 7.3 x 1 .B x 0.9 inches. Supplied with general
purpose probe, battery and operating instructions. Optional probes
available for air, surface, and penetration applications.
cat.!:
:
Ce~.ni#g:
:
i
NO
::
21-2644-02
21-2644-85
21-2644-66
21-2644-67
21-2644-08
DesCrlption: '
475843
476452
476449
476450
476451
TemperatureMeter
GeneralPurpose Probe
Surface Probe
Air Probe
PenetrationProbe
;
Each
67.58
30.45
30.45
30.45
30.45
1159
THERMOMETERS
O
I-m
22-3006
THERMOMETERS - DIGITAL, DIAL, JUMBO DISPLAY,
TRACEABLE
Smooth, stainless steel probe is resistant to acids, bases, solvents,
and most laboratory chemicals. Provides continuous monitoring for
over a year. Includes on/off power switch and switch to change
between °F and °C. Operating temperature range is -58 to 302°F and
-50 to tSO°C with resolution of O.f ° from -20 to 200 ° and 1° outside
of this range. Accuracy is ±1°C between -20 and lOg°C. Extra large,
bright LCD display is 0.4 inch high and readings are updated every
second. Stem length is 5 r/4 inches, stem diameter is 1/8 inches, top
diameter is 2 1/8 inches, overall length is 6 r/2 inches and weight is 1
ounce. Supplied with replaceable silver-oxide battery and certificate
traceable to NIST standard.
Cat;i
:
No~ ~;
Description
Each
22-3006-01
Junrbo Display Dial Thermometer
30.24
22-3008
THERMOMETERS - DIGITAL, FULL-SCALE, TRACEABLE
Full-scale thermometer has large display, wide temperature range,
stainless steel probe and long cable. Operating temperature range is
-58 to 50O°F and -50 to 250°C with 0.1 ° resoJution from -20 to 200 °
and 1° otherwise. Accuracy is 1°C between -20 and tO0°C. Extralarge, bright LCD display is 0.4 inch high and readings are updated
every second. Thermometer has flip-open easel stand, spring clip
and magnetic back. Probe length is 5 ~rh6 inches, probe diameter is
~/8 inch, face diameter is 2 V8 inches, cable length is 10 feet and total
weight is 3 ounces. Silver-oxide battery operates continuously for
1 V2 years. Supplied complete with display, probe, cable, battery and
certificate traceable to NIST standard.
Cat,
No,
Description
Each
22-3008-01
Full Scale Thermometer
35.92
22-3010
22-3003
THERMOMETERS - BIG-DIGIT, DUAL DISPLAY,
MINIMUM/MAXIMUM
MEMORY, TRACEABLE
Big-Digit Thermometer offers easy to read temperatures from across
the lab. Dual displays permit reading ambient and probe temperatures simultaneously, Minimum/maximum memory reading may be
displayed or reset at the touch of a button. Temperature range of
ambient sensor, located inside of thermometer housing, is 23 to
122°F end -5 to 50°C. The external temperature probe with a 1g-foot
cable has an operating range of -58 to 158°F and -50 to 70°C.
Temperature resolution is O.t ° end accuracy is -+1°C. Minimum/maximum memory feature permits storing temperature records
overnight, on weekends or for longer time periods. Unit is equipped
with flip-open stand, a slot for wall mounting and a Velcro TM mounting
strip. Battery runs continuously for 1 year. Housing is high-impact,
chemical resistant ASS plastic with dimensions of 2 3/4 x 4 ~/4 x 3/4
inches and weight is 4 ounces. Supplied with AAA battery and
certificate traceable to NIST.
22-3010-01
1160
Desctiption
Big-Digit Thermometer
Each
30.77
THERMOMETERS - DIGITAL, SENTRY HIGH/LOW,
MEMORY, TRACEABLE
The Sentry High/Low Thermometer has a triple display, which
simultaneously shows high, low and current temperatures. Choice of
°F or °C models with temperature ranges of -58 to 158°F or-5O to 70°C
with resolution and accuracy of 1°. Sensor with 1g-foot cable may be
placed under water, in a refrigerator or in a freezer. Smag ~h6 inch
diameter cable allows refrigerator door to close. Simple one-button
operation resets the high/low memories. Operates continuously for
one year on supplied battery and includes low battery indicator. High
impact ASS plastic housing with flip stand, hanging hook and magnetic
back. Size is 2 5/8x 2 1/2x 3/4 inches and weight is 1.7 ounces. Supplied
with battery and certificate traceable to NIST standard.
Cat.
No.
Description
Each
22-3003-01
High/Low Thermometer, °F
31.42
22-3003-02
High/Low Thermometer, °C
31.42
22-3003-11
Replacement Probe
20.32
22-3003-12
AccessoryStainless Steel Probe
59.27
THERMOMETERS
22-3009
THERMOMETERS
TRACEABLE
- DIGITAL,
REFRIGERATOR/FREEZER,
Accurately monitors temperatures in refrigerators, freezers,water baths
and incubators with the enclosed "temperature buffered" sensor. Small
sealed bottle filled with glycol solution holds sensor and insulates against
rapid temperature changes when doors are opened. Triple display
simultaneously shows high, low and current temperatures. Minimum/
maximum display monitors readings overnight, on weekends or for
other periods of time. Alarm sounds when temperature rises above or
falls below set points. Alarm is programmable in 1° increments. Visual
and audible alarm signals continue for 12 hours even if temperature
returns to non-alarm range. Operating temperature range is -58 to
158°F and -50 to 700C with resolution of 1° and accuracy of +_10C.Tenfoot microcable permits refrigerator door to close. VelcroTM and magnetic strips are provided for mounting of both thermometer and bottle
sensor. High-impact, chemical resistant ABS housing is 2 3/4 x 4 V4 x
3/4 inches and weighs 4 ounces. Supplied with AA battery for one-year
continuous operation and certificate traceable to NIST standard.
C o t ;
:
H~
: :i
22-3005-01
OescrlptiOU
i :
:
Refrigerator/Freezer Thermometer
Each
36,91
22-3009
THERMOMETERS
TRACEABLE
- DIGITAL,
HIGH/LOW
22-3009-01
22-3009-11
22-3009-12
22-3009-13
22-3009-14
22o3009-16
22-3009-17
::
22-3007-01
DIGITAL
Each
High/Low Alarm Thermometer
43.99
COMPACT,
Description
:iech
Digital Thermometer
Replacement Probe
Accessory Micro Probe
AccessorySurface Probe
AccessoryAir/Gas Probe
Nylon Carrying Case
AC Adapter, 120V
399.00
51.32
86.61
119.64
85.10
14.70
30.77
22-2969-01
ALARM,
This thermometer is ideal for use in foods, soils, cuvettes, water baths,
and incubators. Both a high and low alarm may be programmed in 1°
increments. When temperature rises or falls below sot points, a 1 minute
audible alarm signals an out-of-range situation. Alarm automatically resets itself when temperature returns to within set points. Alarm mode
may be switched off when not required. Operating temperature range is
-58 to 500.8°F and -50 to 2600Cwith resolution of 0.1° and accuracy of
+_1°C.Switch from °F to °C or set high/low alarms. Digital display is 1 1/2
inches high and can be read from 10 feet. Stainless steel probe is 71/4
inches long, 1/8 inch diameter, with 3 foot cable and probe clip for handy
storage. Single battery runs continuously for 1 year. Supplied with probe,
AAA battery, and certificate traceable to NIST standard.
cat,:
PORTABLE,
Ideal for routine temperature measurements in soil, foods, cuvettes, gas
systems, water baths, and semi-solids. Operating temperature range is 40 to 3OO°Fand -40 to 150°C with resolution of 0.1" and accuracy of
_+0.2°C. Large, bright LCD display is V2 inch high and readings are
updated three times per second. Displays°F or °C at the push of a button.
Membrane keys offer a splash proof design. Universal stainless steel
probe is 61/4 inches long, probe diameter is ~/8 inch and cable is 5 feet.
Size is 3 1/2 x 5 1/2 x 1 ~/4 inches and weight is 8 ounces. Supplied with
probe, 9-volt battery and certificate traceable to NIST.
22-3007
THERMOMETERS
TRACEABLE
- DIGITAL,
22-2968-02
THERMOMETERS
Model TM-gA is a portable lightweight thermometer with a sealed
membrane touch pad. Will read in both °F and °C with an accuracy of
+_0.2°For °C or ±0.2% of reading, whichever is greater (32 to 120°F).
Temperature range is -40°F to +3gg°F with a resolution of 0.1°F or
°C, and an accuracy of ±B.2°F from -40 to +100°F; _+0.2%from 100
to 300°E Operational status is indicated on display. Constructed of
high impact resistant material making it perfect for field use. With 4
digit, 0.4 inch high backlighted LCD. Model TG-100A has the same
specifications, plus is rechargeable. Includes hard carrying case,
probe holder, rechargeable Nicad battery and recharger.
Cat;
NO~ :
:
:
Description
22-2966-01 TC-100A Digitat Rechargeable Thermometer
Portable, w/Case
22-2988-82
TM-99A Digital Thermometer
Portable, w/Case
Each
246.75
264.76
1161
THERMOMETERS
Ilam
22-2980
DIGITAL THERMOMETER - TYPE K THERMOCOUPLE,
BARNANT
22-2982
DIGITAL THERMOMETERS - TYPE J, K, OR T
THERMOCOUPLE, B A R N A N T
Portable, battery operated meter has a rugged housing and large ~/2 These easy-to-use meters are ideal for basic temperature monitoring
inch digital display with hold function to display °F or °C. Accepts all applications. Meters are available for J, K, or T type thermocouples.
type K thermocouple probes with ANSI miniconnectors. Field CAL Type K thermocouples are the most popular and offer a temperature
allows user to calibrate out error factor of individual probe.
range of -418 to 2501°F (-250 to 1372°C). Type J thermocouples
SPECIFICATIONS:
are rugged and reliable with a temperature range of -328 to t832°F
Temperature Range: -50 to 1999°F (-50 to 1300°C)
(-200 to IOOO"C). Type T thermocouples have the narrowest range
Resolution:
0.1 from -50 to 199.9;
but are ideal for low temperature applications with a range of -418 to
Auto ranging to 1 above 199.9
752°F (-250 to 400°C). The four button keypad is easy to operate
Accuracy:
±5% of reading or ±1°C
and includes on/off, C/F for °C or °F, hold and CAL. The CAL button is
whichever is greater
a "capture" mode for a single (ice) point field calibration offset. Field
Display:
31/2 Digit LCD, 1/2" High
calibration lockout feature prevents tampering and protects factory
Power:
One 9V Battery (Supplied)
settings. Housing is ABS/Polycarbonate impact resistant case with
Battery Life:
t20 Hours continous operation
sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for
Dimensions:
3"W x 6.5"H x I"D
Shipping Weight: 2.01bs.
splash and dust resistance.
One year manufacturer's warranty. Supplied with battery and SPECIFICATIONS:
Accuracy:
-+O.9°F (-+B.5°C) above g9°; _+2°F(zl°C)
instructions. Order Type K probe separately, see 22-2988,
Below 99° plus _+0.2% of reading
Resolution:
0.1 ° between -99.9 ° and 299.9°;
1° below 99.9°
Display:
3 3/4 Digit LCD, 1/2' High
22-2980-01
6OO-OOO0
Type K Thermometer
95.00
Power:
Two AA Batteries (Supplied)
Battery Life:
500 Hours minimum: Low Battery Indicator
Dimensions:
3.3'W x 6.2'H x f.2"D
Shinning Weight: O.71bs
Three year manufacturer's warranty. UL. cUL and CE certif .'c
Sunnlied with naperies instructions and certificate of conformance.
Order prone seoarateb, see 22-2988
Cat.
Bernant
No.
No.
gescriptla~
Each
22-2982-01 60D-1000
Type J Thermomezer
130.00
22-2982-02 600-1010
Type K Thermomezer
130 O0
22-2982-03 600-1020 Type T Thermometer
130.00
SEE OUR
CHROMATOGRAPHY
SELECTION
Chromatography Paper,
Columns, Ferrules, Injection
Port Liners, Septa, Sorbents,
Sprayers, TLC Plates,
Tanks, Vials
1162
SEE OUR SELECTION
OF SIEVE SHAKERS
ATM, CSC, W.S. Tyler
THERMOMETERS
........
,)
22-2986
22-2984
DIGITAL THERMOMETERS - DUAL INPUT J-T-E-K
THERMOCOUPLE, B A R N A N T
DIGITAL THERMOMETER A N D DATA LOGGER DUALOGR, THERMOCOUPLE, B A R N A N T
This meter accepts up to two thermocouple inputs and either J,K,T, or
E thermocouples. Manually stores up to 25 readings in
non-volatile memory. Features three 4-digit LCD displays and 12 button keypad for simplified set up and operation. Functions include on/
off, hold, calibration, °C/°F, J-T-E-K, maximum, minimum, differential
and store. Two point field calibration feature for offset and slope. User
can calibrate probe to known temperatures. Meter automatically stores
and adjusts for inherent probe error enabling unparalleled system
accuracy. Calibration lock out protects NIST traceable factory settings
and prevents tampering with field calibration values. Housing is ABS/
polycarbonate impact resistant case with sealed silicone rubber keypad
and built-in tilt stand. Rated IP 54 for splash and dust resistance.
The DuaLogR is a dual input portable thermometer and data logger,
which can manually store or automatically log up to 1000 sets of
readings in real time. Log interval is selectable from 1 second to 60
minutes. Data can be directly downloaded to the optional infrared
printer or to a computer with the optional RS232 interface adapter.
Meter accepts up to two thermocouple inputs, which can be selected
from the following types: J, K, T, E, R, S, N or B. Temperatures can be
displayed in °F, °C, °R, or °K scales. Resolution and input filtering are
selectable to improve readability during rapidly changing
temperatures. Features three 4-digit LCD displays and 12 button
keypad for easy operation. Capable of displaying minimum, maximum,
and differential readings simultaneously using one or two probes on
selectable, easy-to-read, muOi-data LCD. Two point field calibration
feature for offset and slope. User can calibrate the probe to one or two
known temperatures. Meter automatically stores and adjusts for
inherent probe error enabling unparalleled system accuracy. Calibration feature protects NIST traceable factory settings and prevents
tampering with field calibration values, Housing is ABS/polycarbonate
impact resistant case with sealed silicone rubber keypad and built-in tilt
stand. Rated IP54 for splash and dust resistance.
SPECIFICATIONS:
J: -328 to 1832% (-200 to IOOO°C)
T: -418 to 752°F (-250 to 4OO°C)
E: -418 to 1832°F (-250 to 1000°8)
K: -418 to 2501°F (-250 te 1372°C)
Accuracy:
±O.7°F (±O.4°C) above -238°F (-150°C); ±2°F
(±t°C) Below -238°F (-150°C);
plus ±0.1% of reading
Resolution:
0.1 ° at or below 999.9°; 1° greater 999.9°
Display:
Three 4-Digit LCD Displays,
0.4" and 0.2" High
Power:
Two AA Batteries (Supplied)
Battery Life:
500 Hours minimum; Low Battery Indicator
Dimensions:
3.3W" x 6.2"H x 1.2"D
Shipping Weight: O.71bs
Three year manufacturer's warranty. UL, cUL and CE certified. SupI~lied with batteries, instructions, and certificate of conformance. Order probe separately, see 22-2988.
Temperature
Ranges:
Cat
No~
22-2984-01
Bamant
No.
600-1040
:
Descrlption
Dual J-T-E-K
Thermometer
SEE OUR SELECTION
OF SYRINGE FILTERS
Osmonics, Pall, Whatman
:
EaCh
185.00
SPECIFICATIONS:
J: -328 to 1832°F (-200 to 1000°C)
K: -418 to 2501°F (-250 to 1372°C)
T: -418 to 752°F (-250 to 400°C)
E: -418 to 1832°F (-250 to IOOO°C)
R: 32 to 3241°F (0 to 1768°C)
S: -418 to 2372°F (0 to 1768°C)
N: -418 to 2372°F (-250 to 1300°C)
B: 392 to 3272°P (200 to 18go°c)
Accuracy:
Type 5, K, T, E and N: +0.7°F (±0.4°C)
Above -238°F (-150°C) ±2°F (-+1°C)
Below -238°F (-150°C);
plus ±0.1% of reading
Resolution:
0.1 ° less than or equal to 999.9°;
1° greater than 999.9°
Display:
Three 4-Digit LCD Displays,
6.4' and 0.2' High
Power
Two AA Batteries (Supplied)
Battery Life:
500 hours minimum, Low Battery indicator
Dimensions:
3.3'W x 6.2'H x 1.2'D2
Shipping Weigh1
0.71bs.
Three ~ear manufacturer's warranty. UL, cUL and CE certified. Supsued wlm oatrenes, instructions, and certificate of conformance. Oraer erode seoaretw, see 22-2988.
Temperature
Ranges:
Cat,
No.
22-2986-01
Barnnt
No.
Descriplien
600-1050
Thermometer/Data
Logger
Eech
240.00
1163
THERMOMETERS
.
.
.
.
.
. . . . . . . . . . . .
- - -
• ....
i t •
22-2988-01
i
=
.
.......
¸
22-2988-11
22-2988-41
THERMOCOUPLE PROBES - INTERGRAL HANDLE, BARNANT
Thermocouple Probes for use with Barnant Digital Thermometers and DualLogR thermometer/data logger. Can also be used with any thermocouple thermometer that accepts miniconnectors. Supplied with 5-foot coiled cables with PVC/PVCinsulation and miniconnectors. Cable are ANSI
color coded for easy identification: Type J cables are black, Type K are yellow, Type T are blue, and Type E are purple. Intergral probe handle is
5 1/e inches long glass-filled nylon. Choice of probes includes: general purpose, Teflon® coated general purpose, air/gas, surface and penetration.
General Purpose Probes
22-2988-01
601-1000
22-2988-02
601-0000
22-2988-03
601-2000
22-2988-04
601-3000
Teflon® Coated General Purpose Probes
22-2988.11
685-1757
22-2988-12
685-1657
22-2998-13
685-0057
22-2988-14
685-1257
Air/Gas Probes
22-2988-21
604-1000
22-2988-22
604-0000
22-2988-23
604-2000
22-2988-24
604-3000
Surface Probes
22-2988-31
602-1000
22-2988-32
602-0000
22-2988-33
602-2000
22-2988-34
602-3000
Penetration Probes
22-2988-41
603-1000
22-2988-42
603-0000
22-2988-43
603-2000
22-2988-44
603-3000
Maximum :
Temperature
Prabe
Length,in
Each
J
K
T
E
1400°F (760°C)
1652°F (900%)
550 °F (288°C)
1600°F (871°C)
4 15/16
4 15/16
4 15/16
4 15146
36.75
36.75
40.95
42.00
J
K
T
E
302°F
302°F
302°F
302 °F
(150%)
(150°C)
(150°C)
(150°C)
10
1O
10
10
57.75
57.75
57.75
59.85
J
K
T
E
572"F
572 °F
572°F
572°F
(300°C)
(30O°C)
(3go°c)
(3OO°C)
8 1/e
8 1/e
81/8
8 1/8
48,30
48.30
48.30
58.80
J
K
T
E
1200°F (649°6)
1200°F (649°C)
650 °F (343°C)
1200°F (649°C)
9 15/16
9 15/16
915/~e
915he
55.05
56.65
55.65
68.25
J
K
T
E
t4OO°F (760%)
1652°F (9OO°C)
550°F (288%)
1600% (871°C)
4
4
4
4
39.90
39.90
39.90
44.10
/
22-2986, 22-2987
21-2649
ACCESSORIES - FOR 22-2986, DUALOGR,
THERMOMETER AND DATA LOGGER, BARNANT
TEMPERATURE METER - PORTABLE, BATTERY
OPERATED, MODEL 309, CORNINGo
Accessories for DuaLogR thermometer and Data Logger. The
infrared printer is ideal for on-site documentation. Data is transferred
by infrared output, no cable to connect, just line up data transmission
LED located on top of instrument and position printer within 18 inches.
Print readings in real time from every three seconds to every 60 seconds or automatically print previously stored data. Printer supplied with
one roll of paper. Optional printer power adapter 110-240V, 50-6gHz
with 6-foot power cord. RS232 interface adapter connects data logger
to computer with 9-pin serial port for easy downloading of data. Does
not include software. Optional power adapter 115VAC for for DualLogR.
The Model 309 is a microprocessor based temperature measurement
system that uses a thermistor type of temperature input probe. This
portable, handheld unit accurately measures temperature in liquids, solids, and gases. Features include push button operation, LCD readout,
temperature display in °C or °E HI/LO recall, low battery indicator, and
auto off. Operating temperature range from -50 to 150°C with resolution
of 0.1°C and accuracy of ± 0.4°C. Approximately lOg hours of operating
battery life. Splash-proof housing with easy to use membrane keypad.
Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless
steel general purpose probe, wrist strap, battery and operating instructions. Optional probes available for air and penetration applications.
Cal.
Coming
Ne~
:
No.
Descrlptian
Each
21-2649-02
475852
Temperature Meter
155.40
21-2649-05
476604
GeneralPurpose Probe
60.90
21-2649-07
476605
Air Probe
76.65
21-2649-08
476606
Penetration Probe
60,90
22-2987-01
22-2987-02
22-2987-08
22-2987-04
22-2987-00
1164
600-0080
600-0082
37455-71
600-0090
600-0070
Infrared Printer
235.08
PrinterAdapte5 100-240VAC 65.00
PrinterPapeE Pkg. of 6 Rolls 12.00
RS232 Inte~ace Adapter
95.00
DuaLogRAdapter, t15VAC
31.00
THERMOMETERS
..-=
Ut
21-2650
TEMPERATURE METER - PORTABLE, BAI"rERY
OPERATED, MODEL 3 1 0 , C O R N I N G ®
The Model 310 is a microprocessor based temperature measurement
system that usesa K- typethermocouple with detachableprobe handle.This
portable, handhetdmeter is ideal for a wide rangeof temperature measurement applications. Features include push button operation, LCD readout,
temperature display in °C or oF,HI/LOrecall, tow battery indicator, and auto
off. Operatingtemperature rangefrom -50 to 950°C with resolution of 0.1°C
(-50 to 150) and 1°C (>150). Temperatureaccuracy is _+0.5°C or _+0.5%
(-50 to 150) and ± 1.0°C or _+0•5% (>150). Approximately100 hours of
operating batterylife. Splash-proof housing with easyto use keypad. Overall
dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general
purpose probe, wrist strap, battery and operating instructions. Optional
probes availablefor air, surface and penetrationapplications.
Cat; :
N0~
Carn!0it
" : N0
21-2650-02
21-2650-05
21-2650-06
21-2550-07
21-2650-08
21-2650-09
475853
476607
476610
476608
476609
470441
i
: : :
Descrlpt it~
:.!:
TemperatureMeter
General Purpose Probe
Surface Probe
Air Probe
PenetrationProbe
Probe Handle
i
:
Each
263.12
30.57
30.45
80.45
30.45
40.05
22-3035
HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M /
M A X I M U M M E M O R Y , TRACEABLE
Ideal for monitoring around-the-clock and for routine measurements
of relative humidity and temperature. Suitable for quality control
applications. Continuously and simultaneously displays relative
humidity and temperature in °E or °C with dual-recall memories.
Minimum and maximum memories may be displayed or cleared at
any time with the touch of a button. Environmental conditions can be
monitored overnight, on weekends, or for longer time periods.
Temperature range is 32° to t 22°F and 0° to 50°C with resolution and
accuracy of 1° . Humidity range is from 25 to 95% with resolution of
1%RH and accuracy of _+2% in mid-range to _+4% at the extreme
ends of range. East-response solid-state sensor displays changes in
less than 30 seconds. Large, easy-to-view 5/8 inch high digits are
updated once every second• Meets federal requirements for CLIA
specification 493.1207 for monitoring temperature and humidity in
labs. Case is shock and chemical-resistant ABS plastic. Size is 2 5/e x
3 7/8x 3/e inches and weight is 2 1/2ounces. Supplied with wall mount,
bench stand, solid-state sensors, switch to read °F/°C, two AAA
batteries and certificate traceable to NIST. Choice of three models
available. Catalog number 22-3035-01 offers digital humidity/temperature with dual minimum/maximum memories. Model 22-303502 offers digital humidity with minimum/maximum memory but
without temperature. Catalog number 22-3035-03 offers digital
humidity/temperature but without memories•
Cat;
NOi ~ . . . . .
PEN - DIGITAL,
Pocket pen with clip is easyto carry and is idealfor measuring humidify and
temperature levels. Pen continuously and simultaneously displays both RH
and °F or °C with dual-racall memories. Memory displays highest ano
lowest humidity/temperatura readings observed overnight or during any
time period. Easy-to-read LCD display is 1 1/2 inches high and is upoatea
once every second. Pocket pen has fast-response solid-state sensors.
which respondto changes in less than 30 seconds. Temperature range ~s
32° to 122°E and 0° to 59% with resolution of 0.1° and accuracy of +_1°C.
Relative humidity range is 2 to 98% with resolution of 1% and accuracy of
_+2%at mid-range to 4% at ends of range. Supplied with two s [ver-oxloe
batteriesfor 6 month of continuous operation. Caseis high-impact, chemical resistantABS plasticwith dimensions of 5 Vex 1 x 7/8inches and weight
of 1 1/2 ounces. Supplied with batteries and certificate traceable to NIST
Cat.
NO.
" .
22-3037-01
"
Descdptlon
:
22-3036-01 Hygrometer/Thermometer, Min/Max Memory
22-3035-02
HygrometerOnly with Min/Max Memory
22-3035-03 Hygrometer/Thermometer without Memory
22-3037
HYGROMETER/THERMOMETER
M E M O R Y , TRACEABLE
i
Des¢rlp0ee
Each
Hygrometer/Thermometer Pen
48.23
]Each
60.59
51.67
57.77
SEE OUR SELECTION
OF FILTER APPARATUS
Nalge Nunc, Osmonics,
Pall, Whatman
1165
THERMOMETERS
22-3036
HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M /
M A X I M U M MEMORY, TRACEABLE
Continuously and simultaneously displays relative humidity and
temperature in °F or °C with dual-recall memories. Minimum and maximum
memories may be displayedor clearedat any time with the touch of a button.
Conditions can be monitored overnight, on weekend or for longer time
periods. Contains ambient relativehumidity and temperaturesensors within
case and externaltemperature sensor with lO-foot cable. Externaltemperature probe rangeis-58 to 158°Fand -50 to 70°C.Ambient sensorrangeis 23
to 122°Fand -5 to 50°C. Temperatureresolution is t ° and accuracyis _+1°C.
Humidity rangeis 25 to 95% with resolution of 1% BA and accuracyof ±2%
in the mid-range to ~ % outside of mid-range. Fast response solid-state
sensors show display changes in lessthan 30 seconds. Large,easy-to-view
1 ~/8 inch high digits are updatedonce even/second. Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and
humidity. Caseis shockand chemical-resistant. Sizeis 3 7/8x 4 r/4 x3/4inches
and weight is 5.4 ounces. Supplied with flip-open stand, wall mount, AAA
batteryand certificatetraceableto NIST
22-3036-01
Digital Hygrometer/Thermometer
|.oh
56.50
22-3039
HYGROMETER/THERMOMETER - DIGITAL, TRACEABLE
ideal for constantly monitoring labs, fume hoods, plant areas and
storage facilities. Provides humidity and temperature readings
instantly. Humidity range is 25 to 95%BH with resolution of 1% and
accuracy of _+2%RH at mid-range to _+4% at ends of range.
Temperature range is 32° to 122°F and 0° to 50°C with resolution of
0.1 ° and accuracy of ±1 °C. Large, easy-to-read LCD has V2 inch high
digits. Modern design is housed in a rugged ABS plastic case with
dimensions of 3 ~/2 x 5 x 7/8 inches and weighs 6 ounces. Single AA
battery provides I 1/2 years of continuous operation. Supplied
complete with screw for wall mounting, plastic stand for bench use,
battery and certificate traceable to NIST.
Cal.
No,
Description
Each
22-3039-01
Digital Hygrometer/Thermometer
48.03
RECORDING THERMOMETERS
WEATHER H A W K RECORDING THERMOMETER
22-3038
HYGROMETER/THERMOMETER - DIGITAL, MEMORY,
TRACEABLE
Unit constantlymonitorstemperature and humiditywith memorycapabilityto
recall high and low readings. The instrument is always on, as there is no off
switch, and makes continuous readings.Equippedwith an ambient humidity/
temperature sensor inside of the housing and an externaltsmperatureprobe
with a 10 foot cable. Displaysimultaneouslyshows probetemperature,ambient temperature and ambient humidity Minimum anD maximum memory
readingsmay be recalledor clearedwith the rouce of a button. Humioayrange
is 25 to 95% RH with resolution of 1% and accuracyof _+2%at mid-rangeto
-+4°/°at ends of range, ambient temperature range is 32" to 122°Fand O" to
50°C. ExtemaJtemperature sensor range is -58° to 158°Fand -50° to 70°C
Temperature resolution is 0.1° and accurac~ is _+1"0.Bright LCD Digits are
V2 inch high. Case is high-impact, Chemical resls~am ABS nlastic with
dimensions of 3 V2 x 5 x 7/8inches and weight is 6 ounces.Two AA eanenes
provide one year of continuous operation. Suoolled comolete with ulastlc
stand, internal humidity/temperature sensor, and external zemeerature
sensor with 10 foot cable, AA batteriesand certificatetraceableto N S]~
22-0038-01
1166
Digital Hygrometer/Thermomezer
56.43
Provides a continuous record of temperature variations over a 7 day
period. Accuracy is ±I°E It can be used outdoors or in the laboratory
area, for example, in environmental cabinets. Dimensions are 13 x 7
x 7 inches high. The electrically driven drum revolves one complete
turn in seven days. The chart, in 2° divisions, ranges from -40 ° to
120°F and has colored bands which clearly indicate the significant
temperature zones for convenient reading. Complete with 40 foot
capillary tubing, 3-wire cord and plug, 52 charts, ink and
instructions. For operation on 110 volts, 60 Hz, AC.
(:at.
No.
Description
Each
22-2995-01
Weather Hawk Thermometer
600.00
SEE OUR SELECTION
OF FUME HOODS
Captair, Kewaunee, Labconco
THERMOMETERS
",4
22-3080
THERMOMETERS - R E C O R D I N G , P E R M A N E N T D R Y
STYLUS, PTC
22-3050
THERMOMETERS
BACHARACH
- R E C O R D I N G , TEMPSCRIBE,
These recording thermometers have a wide range of laboratory
applications such as continuous recording of temperatures in heated
or refrigerated incubators, controlled temperature rooms,
fermentation cabinets or similar compartments. They can also be
used for meteorological recordings if suitably protected from rain,
snow and direct sunlight. Each instrument consists of a hi-metallic
coil which has a thermal responsiveness of 0.5°F, recording pen and
chart which is turned by a sturdy spring-wound clock, all mounted in
a strong plastic case which can be flush mounted, suspended or set
on a level surface. Temperature chart is 4 1/2 inches in diameter. Each
unit is suppiied complete with two marker pens and 100 charts.
Ca
No.
:
Temperature
range
onecharf Temp.
~rn dv.
Time
dv.
:
:Each
22-3050-01
22-3050-02
22-3050-05
22-3050-06
22-3050-09
22-3050-11
-30 to 120°F 7 days 5°F
3 hr,
-30 to 120°F 24 hr.
5°F 15 min
40 to 10O°F 7 days 2°F
3 hn
40 to t00°F
24 hr
2°F 15 min
-tO to 50°F
7 days 2%
3 hr
30 to 50°0
7 days 2°C
3 hr.
RECORDER CHARTS-FOR 22-3050
Catalog suffix numbers correspond with those of the
Recorders, e.g., 22-3051-01 is for 22-3050-01.
Cot
:N~!!i ~' i~i:~:~il ~
~i~
: :i;
!
~
390.02
390.02
390.02
390.02
390,02
390.02
22-3050
Pkg
Qiy~Price!
~,:
22-3051-01
22-3051-02
22-3051-55
22-3051-06
22-3051-09
22-3051-11
100
100
105
100
100
100
-27.00
-27.00
- 27.00
- 27.00
- 27.00
-27.00
M A R K E R PENS - F O R TEMPSCRIBE R E C O R D I N G
THERMOMETERS
Two marker pens in two-compartment Mylar packet for use with 223050 Recording Thermometers. For use at -30 to +150°F; 0-100%
humidity. Provide 6 months to one year continuous use.
Cat;
::
:
N~
COoi":
22-3064-02
Red
Pko
: : Qty--Price i
2-
22.83
Portable unit records temperatures permanently over periods of up
to 24 hours or up to 7 days, Accuracy is _+2%of full scale range. Can
withstand rugged environment and rough handling. Ideal for use in
refrigerators, coldrooms, dairies, drying sheds, greenhouses as well
as in schools, hospitals, and offices. For wet environments or
extremely high humidity, the unit can be placed in a heavy
polyethylene bag or sealed container, Clock movement is spring
wound. A permanent, sharp stainless steel stylus presses against a
plastic coated 3 5/8 inch circular chart leaving a distinct black line
against the white paper and blue temperature and time graduations.
NIST certification available upon request. 100 charts are provided.
Cat~ -:
HO~!
=
Range°F/°C
Tlmerahge
=
22-3080-01
22-3080-02
22-3080-03
22-3080-04
22-3080-05
22-3080-06
22-3080-07
22-3050-08
22-3580-09
22-3080-10
22-3080-11
22-3080-12
22-3080-13
22-3080-14
-40 to 160°F
24 hrs.
40 to 160°F
7 days
0 to 10O°F
24 hrs.
0 to 1OO°F
7 days
20 to 220°F
24 hrs,
20 to 220°F
7 days
-5 to 50°C
7 days
-5 to 105%
24 hrs.
-5 to 105°C
7 days
-5 to 5O°C
24 hrs.
20 to t20°F
24 hrs.
20 to 120°F
7 days
-30 to 7O°F
24 hrs.
-30 to 70°F
7 days,
22-3080-15
-40 to 70%
24 hrs.
22-3080-16
-40 to 70°C
7 days
RECORDER CHARTS-FOR 22-3080
Catalog suffix numbers correspond with those of
Recorders, e.g., 22-3083-01 is for 22-3080-01.
Car.;
NQ~
:
~
22-3083-01
22-3083-82
22-3083-03
22-3083-04
22-8883-05
22-3083-06
22-3083-07
22-3883-08
22-3083-09
22-3083-10
22-3083-11
22-3083-12
22-3083-13
22-3083-14
22-3083-15
22-3083-16
MOUNTING
Each
504.00
504.00
504.00
504.00
504.00
504,00
504.00
504.00
504.00
504.00
504.00
504.00
504.05
504.00
504.00
504,00
22-3080
9kg
Qty-Pdce
100
100
100
100
100
180
180
100
100
100
100
100
100
100
100
100
-13.50
-13.50
-13.50
- 13.50
-13.50
- 13.55
-13.50
- 13.50
-13.50
- 13.50
- 13.50
- 13.50
-18.50
- 13.50
-13.50
- 13.50
BRACKET - STAINLESS STEEL
Cet, i .
22-3081-01
Description
" Each
Mounting Bracket
32.81
1167
THERMOMETERS
-,%
cO
22-3365
RELAY CONTROL - SOLID STATE, MECHANICAL,
P R I N C O T688
22-3230
THERMOREGULATOR - FULL RANGE TYPE,
M A G N A - S E T ~, P R I N C O
Fully adjustable, rapid setting thermoregulator with an accuracy to
0.002°0. Exclusive Pdnco Magna-Set principle brings accuracy and
sensitivity formerly unavailable in adjustable temperature controls.
Unique design features include a variable electrode with a magnetically controlled micrometer adjustment which permits changes of
0.005°C in operating temperature and improved mercury trap (or
reservoir) used in making the preliminary, rough adjustment.
Controls a well agitated constant temperature bath of good design to
within 0.01°C Under ideal conditions a variation as little as 0.002°C
has been maintained. Overall length is 335 mm including a two-piece
detachable connector and cord. Diameter of ooey iS 14 ram, A suoer
sensitive relay (22-3362-11 Js recommenaea: maximum capacity is
3 milliamperes at 110 volts 60 Hz. AC.
-~"
22-3230-11
DescriFtion
Thermoregulazor
Each
420.00
For use with laboratory thermoregulators and thermostats. Unit combines solid state and mechanical components to obtain the advantages of both. There are two input binding posts, two AC receptacles
and a load indicating pilot light. A one second time delay prevents
chattering. This relay controls a resistive load up to 1000 watts. It
operates on 115 volts, AC and provides an activating current of 100
microamperes at 7 volts DC. Complete with a heavy-duty line cord
and plug. Case measures 4 x 4 x 2 inches.
Cat.
No.
Description
22-3365-01
Relay Control
SEE OUR
GLOVE SELECTION
Disposable Gloves,
Reusable Gloves,
Chemical Resistant Gloves,
Temperature Resistant Gloves
22-3362
RELAY CONTROL - SOLID STATE, PRINCO T681SS
A heavy duty solid state controller for use with laoorazory mermoregulators, especially the 22-3230-1t. Controls cads frorr 25 to 1500
watts. "Percent Power" ala regulates power from O zo 100%.
Provides signal current of only 6 microamoeres to tl~e thermoregulator. With twin pilot lights, controlled Ioaa aria convemence outlets
and heavy duty 3-prong plug. Case measures 7 x 6 x 4 inches Ii~gh.
For operation on 115 volts. AC
22-3362-11
1168
Relay Control
Each
630.00
SEE OUR
BALANCE SELECTION
A & D Weighing, Acculab,
Ohaus, Sartorius,
Thermo Cahn, Troemner
Each
288.75
THERMOMETERS
SPECIAL-USE THERMOMETERS
...a
...a
14-5000
THERMOMETERS
- "EXACT-TEMPE"
ERTCO
Consists of an NIST traceable, Teflon®-coated thermometer in an unbreakable plastic bottle filled with propylene glycol, ethylene glycol or
vermiculite. Each thermometer has an individual serial number and has been listed against a standard calibrated at the National Institute of
Standards and Technology (NIST). A certificate of accuracy is supplied with each thermometer, Velcro is affixed to each bottle permitting the
thermometer to be attached to the wall or door of the instrument, reducing space and breakage problems. All thermometers are total
immersion.
cat
Range,
Length,
Div.,
Type
~
Liquid
Each
No. :
nslremeet
: C
ran.
C
14-5000-01
14-6000-02
14-5000-03
14-5000-04
14-5000-05
14-5000-08
14-6000-07
14-6000-08
14-5000-09
14-500G-10
14-5000-11
14-6000-12
Ultra-low Freezer
Freezer
Blood Bank
Refrigerator
Incubator
Oven
Oven
Freezer
Refrigerator
Incubator
Oven
Oven
-90 to 20
-30 to 0
-5 to 20
-5 to 15
-18 to 50
20 to 130
35 to 200
-30 to O
-5 to t5
18 to 50
20 to 130
35 to 200'
145
125
125
125
135
135
145
1 O0
125
1 go
135
145
1.0
0.5
0.5
0.5
0.5
1.0
1.0
1 .O
0.5
1 .O
1.0
1.0
Spirit
Spirit
Spirit
Spirit
Spirit
Spirit
Spirit
Mercury
Mercury
Mercury
Mercury
Mercury
PP Glycol
PP Glycol
Eth. Glycol
Eth. Glycol
Eth. Glycol
Vermiculite
Vermiculite
PP Glycol
PP Glycol
Eth. Glycol
Vermiculite
Vermiculite
58.48
46.41
70.14
46.41
46.41
48.41
78.01
46.41
46.41
46.41
46.41
78.01
SEE OUR SELECTION OF TUBING
Fluoropolymer, Latex, Norprene, Polyethylene, Polyvinyl Chloride,
Polyurethane, Pure Gum Rubber, Silicone, Teflon, Tygon
SEE OUR SELECTION OF PIPETTORS
BD Medical, BrandTech, Eppendorf, Finnpipette, Jencons,
LabBest, Oxford, Popper, Volac
1169
THERMOMETERS
~(~
14-5930
THERt~4OMETERS - PRECISION., FOR SPECIAL APPLICATIONS, ERTCO
All thermometers are serialized for the purpose of traceability and all are accurate to within NIST (NBS) tolerances.
rv~
IC
1.0
1.0
1.0
10
0.5
0.5
1.0
1.0
0.1
0.1
0.5
05
1.0
1.0
1.0
1O
1.0
1.0
0.5
0.5
1.0
10
1O
1.0
1O
1.0
1.0
10
t0
1O
1.0
1.0
2.0
20
tO
10
05
SFeda
:fea!utes*
1, 2
1, 2
Applkatlons
incubator, Water Bath
Incubator, Water Beth
Incubator, Water Bath
Incubator, Water Bath
Incubator, Water 6aths
Incubator, Water Bath
Incubator, Water Bath
Incubator, Water Beth
Coliform Incubator
Coliform Incubator
Block Heater, Water Bath
Block Heater, Water Bath
Block Heater, Water Bath
Block Heater, Water Beth
Short Immersion Bath
Short Immersion Bath
Blood Bank, Refrigerator
Blood Bank, Refrigerator
Incubator, Water Bath
Incubator, Water Beth
Autoclave, Max. Reg
Autoclave, Max. Reg
Ovens, Oil Baths
Ovens, Oil Baths
Ovens
Ovens
Ovens
Ovens, Oil Baths
Ovens, Oil Baths
Ovens, Oil Baths
Ovens, Oil Bathe
Ovens
Vacuum Ovens
Vecuum Ovens
Vecuam Ovens
Vacuum Ovens
Enzymology
14-5930-03
20 to 100
305
76
14-5930-13
20 to 100
305
76
14-5969-64
0 to 60
250
1 O0
14-5030-14
0 to 80
250
100
14-5930-01
0 to 50
305
150
i
14-5930-11
0 to 50
305
150
1
14-5930-02
O to 70
330
150
1
14-5930-12
6 to 70
330
150
1
14-5930-05
34.5 to 46
237
76
2
14-5930-15
34.5 to 46
237
76
2
14-5929-01
25 to 57
175
35
2
14-5929-11
25 to 57
175
35
2
14-5929-02
0 to 100
225
35
14-5929-12
0 to 100
225
35
14-5928-01
O to 50
1 O0
12
14-5928-11
0 to 50
1 O0
12
14-5927-01
-5 to 20
t 52
Total
2
14-5927-11
-5 to 20
152
Total
2
14-5930-06
25-37-56
240
76
2
14-5930-16
25-37-56
240
76
2
14-5930-07
80 to 135
200
Total
14-5930-17
80 to 135
200
Total
14-5925-01
O to 300
405
125
i
14-5925-02
O to 300
455
150
1
14-5925-03
0 to 300
610
305
1
14-5925-04
0 to 200
610
305
1
14-5925-14
0 to 200
610
305
1
14-6925-05
0 to 200
280
76
1
14-5925-15
0 to 200
280
76
1
14-5925-06
0 to 200
405
125
1
14-5925-16
0 to 200
405
125
1
14-5925-07
0 to 350
455
150
1
14-5926-01
24 to 130
135
Total
14-5926-11
24 to 130
135
Total
14-5926-02
35 to 200
180
Total
14-6926-12
35 to 209
180
Total
14-5032-01
24 to 38
300
95
*Special Features:
1. Immersion enlargement on thermometer stem 2. Arrows on scale indicating critical temperature
SEE OUR SELECTION OF BRUSHES
Assay, Beaker, Bottle, Buret, Camel Hair, Carboy,
Centrifuge Tube, Cylinder, Flask, Graduate, [mhoff Cone,
Pipet, Static Master, Test Tube
1170
Teflo.®
coaled
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yea
No
Yes
No
Yes
No
No
No
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Each
44.73
52.60
32.65
40.53
31.81
39.58
39.06
46.83
68.04
75.81
43.36
51.13
42.94
50.71
42.94
50.71
25.51
33.28
33.07
40.95
52.50
60.99
38.95
46.30
62.05
62,05
69.82
38.32
38.32
42.90
49,77
62.65
35.91
43.68
36.75
44,52
74.76
THERMOMETERS
THERMOMETERS - ASPHALT TESTING, THERMOMETER
ONLY
C=ti
NO,
14-5399-01
14-5399-02
Range,°F
:
|=ch
50-450
50-600
50,77
26.26
d
THERMOMETERS - CLINICAL, ASEPTO ®, B'D T M
Accurate and dependable fever thermometer with easy-to-read blue
scale. Reads in Fahrenheit. Supplied in white plastic case with Lok-ln
feature.
Cat;
:
Pkg
No, ~
9-DTMNo.
Typebulb
Qly- price
14-5885
THERMOMETERS - AIR I M M E R S I O N , CLEAN R O O M ,
PTC ®
These instruments are engineered to accurately measure ambient air
temperature within +_2% of full scale range. Ideally suited for
temperature-controlled clean rooms, cold rooms, laboratories and
large areas or volumes used in environmental testing, Three
temperature ranges are available: -20°F to +160°E O°F to 250°F and
O°F to 50O°E Dimensions: 2 inch diameter x height, 1 inch. An
ancillary hand is available for this instrument. It is held by a magnetic
clutch and will retain a maximum or minimum reading. One year
warranty. NIST certification available upon request.
Cal~
No,
14-5885-01
14-5885-02
14-5885-03
lu~ II
Range,~:
°F . . . . . . .
-20 to 160%
0 to 250°F
0 to 500°F
Subdlv.
2°
2°
5°
With Ancillary Hand
14-5885-04
-20 te 160°F
14-5885-05
0 to 250°F
14-5885-06
0 to 500°F
2°
2°
5°
.....
Each
68.25
68.25
68.25
14-4795-01
14-4795-02
524015
524025
Oral
Rectal
66-
29.42
29.42
14-5935
THERMOMETERS - D E W P O I N T
Totalimmersion thermometers with an overalllength of 255mm.
Cat.!
Noi
14-5935-91
14-5935-02
ana
Re,
-30 to 110
-90 to 40
Sub~
: dlv;
Each
1°
1°
30.66
51.34
87.93
87.93
87.93
THERMOMETERS - ASPHALT TESTING
Supplied with penetration nickel plated brass armor case. Overall
length 11 inches; 5 ° divisions.
Cat;
Noi
14-5398-01
14-5398-02
:
Thermometer Only
14-5399-01
14-5399-02
Renge~°F
50 - 450
50 - 600
Each
56.38
56.38
50 - 450
50 - 600
50.77
26.26
THERMOMETERS - ASPHALT TESTING, POCKET TYPE
100 - 450°F with epoxy coated bulb for penetration protection; 5
divisions. Complete with aluminum protective case.
No.
14-5406-01
14-5400-02
Range~ F
~~
Thermometer w/Case
Refil~ Only
Each
44.52
35.70
14-5780
THERMOMETER - DOUBLE SCALE, I N D O O R , COMFORT
METER TM, TAYLOR
With permacolor tube and magnifying lens. Wood grained frame
finish. Bold white numbers and graduations on a brown background.
Ranges are -60 to 130°F and -50 to 55°C. Overall dimensions are
7 5/8x 2 1/4 inches.
Ce|. :
No; :
14-5780-01
~
Description
Double Scale Thermometer
~
Each
11.95
1171
THERMOMETERS
C'q
r~
14-5850
THERMOMETERS - M A X I M U M REGISTERING,
MERCURIAL, W I T H PROTECTIVE CASE
14-5840
THERMOMETER - M A X I M U M
REGISTERING, TAYLOR
AND MINIMUM,
SELF
Complete with setting magnet and improved tube fastening. With a
range from 40 to 130°F in two degree divisions. High temperature is
registered at top of one side and low at top of other side. Mercury
filled. Dimensions are 10 V2x 2 3/sx 1 ~/4 inches.
o~
:
14-5840-01
:
Thermometer
:
Each
23.49
For general testing in applications where it is impractical to make an
immediate reading. The mercury column will not recede until shaken
down or reset similar to fever thermometers. Overall length is 61/2
inches. Available in fully enclosed pocket case or in open-faced armor
case. Cases are anodized aluminum and provided with pocket clip.
Cat.
Scale
SubNoi
ra~e
dlv.
Each
Complete
14-6850-11
14-6950-12
14-5650-13
14-5650-15
cat.
N0.
O to 220°F
50 to 3OO°F
50 to 40O°F
-20 to 150°C
2°
2°
2°
1°
renge
Replacement Thermometer-for 14-5850
14-5855-11
O to 220°F
14-5855-12
50 to 300°F
14-5655-13
50 to 400°C
14-5359-15
-20 to 150°C
45.36
45.36
45.36
45.36
Each
37.60
37.90
37.90
37.90
14-5842
THERMOMETER - M A X I M U M
REGISTERING, DUAL SCALE
AND MINIMUM,
SELF
Ranges are -40 to 5O°C in 1° divisions; -40 to 120°F in 2° divisions.
Mercury filled. Reset with the press of a button.
14-4975
14-5842-01
Thermometer
MICROCHEMISTRY KITS
SEE
Corning, Wheaton
12-9960 TO 12-9965
]172
75.00
THERMOMETERS - MERCURIAL, FLOATING DAIRY,
FAHRENHEIT
Has a transparent coating for protection against shattering on sides
of vat. The coating does not interfere with reading, and in case of
breakage prevents contamination by mercury and glass fragments;
is not affected by action of hot milk and will have no effect on the taste
or quality of the milk• Diameter is 15 mm; length is 270 mm.
Cat,
Range,
SubNe.
°F
dlv.,°
Eeck
14-4975-Ol
20 to 160
2
32.76
14-4975-02
20 to 220
2
34.02
THERMOMETERS
Q
14-5880
THERMOMETERS - SURFACE TEMPERATURE, DUAL
MAGNET, GLASS COVER, PTC ®
14-5900
THERMOMETERS - SPOT CHECK, 1 a/4 INCH DIAL, PTC~
Employs a bimetallic coil sensor which has direct contact with the
surface to be measured. In response to temperature, the sensor
expands or contracts causing the 1 3/4 inch dial itself to rotate. This
thermometer reads temperatures of all flat surfaces such as dies, hot
plates, heavy sheet metal, etc. It also reads ambient temperatures in
enclosed spaces, as well as in noncorrosive liquids and gases, up to
1000°E Accuracy is _+2% of full scale. NIST certification available
upon request.
Cat;
No.
:
Range,
F/°C " i
,
14-5900-01
14-5900-02
14-5900-03
14-5g00-04
14-5900-05
14-5900-06
14-5900-07
O to 270°F
50 to 320°F
50 to 5OO°F
50 to 1000%
10 to 160°C
10 to 260%
O to 525°C
S..b, :
dlv.
Each
2°
2°
5°
10 °
1°
2°
5°
36.75
36.75
36.75
21.00
36.75
36.75
21.00
Designedto be used on hodzontalor ferrous non-horizontalsurfaces. Dimetallic sensor is locatedin a draft shieldand is in virtual thermal contactwith
surface to be measuredgivinga relativelyquickresponsetime. Glasscovered
dual magnetsurface thermometeroperates across a total rangefrom -100
to +750°Fand-70 to +400°Cwith an accuracyof ±2%. Diameteris 2 inches.
Two Alnico magnetshold it securely in placeon horizontalor non-horizontal
steel or ferrous metalsurfaces. NISTcertificationavailableupon request.
CaI~
Na~
:
14-5880-01
14-5880-02
14-5880-03
14-5880-04
14-5880-05
14-5880-06
14-5880-07
14-5080-08
14-5880-09
14-5880-10
Range,
"F/°C
Subdlv,
Each
-100 to 160°F
0 to 150°F
O to 250°F
0 to 5OO°F
50 to 750°F
-70 to 70°C
-15 to 65%
-20 to 120°C
-20 to 250°C
10 to 400%
2°
1°
2°
5°
10 °
2°
1°
1°
2°
5°
52.44
52.44
52.44
52.44
29.95
52.44
52.44
52.44
52.44
29.95
THERMOMETERS - SPOT CHECK, I 3/4 INCH DIAL,
N O N - H O R I Z O N T A L SURFACES, PTC ®
Similar to 14-5900 but includes magnet and leaf spring for use on
non-horizontal ferrous surfaces or for permanent mounting. NIST
certification available upon request.
Car
: ~
" Range
NO,
: "Fp~ '
14-5901-91
0 to 270%
14-5901-02
50 to 320°F
14-5901-03
50 to 5OO°F
14-5901-04
50 to IOOO°F
14-5901-05
10 to t60°C
14-5901-06
10 to 260°C
14-5901-07
0 to 525°C
i
THERMOMETERS - SPOT CHECK, i
M A X - M I N , PTC ®
Sub, ; '
diW
2°
2°
5°
10 °
1°
2°
5°
3/4
:
Each
45.51
45.51
45.51
45.51
45.51
45.51
45.51
I N C H DIAL,
Similar to 14-5901 but with Max-MJn pointers to indicate lowest and
highest temperatures reached during the thermometer's exposure.
NIST certification available upon request.
Cat.
Ne~
14-5902-01
14-5902-02
14-5902-03
14-5902-04
14-5902-06
14-5902-07
i
Range,
:
"EpC
O to 270°F
50 to 320°F
50 to 500°F
50 to IOOO°F
10 to 260°C
0 to 525°C
gub.~ :
dl~;i
2°
2°
5°
10 °
2°
5°
!aCK
48.98
48.98
48.98
40.08
48.98
48.98
14-5881
THERMOMETERS - SURFACE TEMPERATURE, PTC ®
Thermometers are fully enclosed to protect bimetal from dirt and dust.
Diameteris 2 inches. Requires either a small magnet clamp to hold it
securely in place on non-horizontal steel or other ferrous metal surfaces, or heavy silicone grease which can be used to stick the thermometer to any flat surface. NIST certification available upon request.
Cob
No;
i
Range :
"F/"C
~
Subi ~
~ dlv~
:
EaCh
14-5881-01
-50 to 250~F
2°
47.00
14-5881-02
-50 to 110°C
2°
47.00
14-5081-03
0 te 300°F
2°
47.00
14-5881-04
-10 to 150°C
2°
47.00
14-5801-05
70 to 370°F
2=
47.00
14-5881-06
20 to 180%
2°
47.00
MAGNET AND LEAF SPRING, FOR 14-5881 THERMOMETER
Clampholdsthermometersecurely in placeon steelor otherferrous metals.
Cat~
Ne~
Description :
.
~ Each
14-5882-01
Magnetic Thermometer Clamp
5.00
THERMOMETER ADHESIVE-SILICONE, FOR 14-5881 THERMOMETER
Silicone grease holds thermometer securely on any flat surface.
Caf~
No~
14-5983-01
Description i
i
Thermometer Adhesive
Each
7.08
1173
THERMOMETERS
14-5903
THERMOMETERS - SURFACE, MINIATURE SPOT
CHECK, PTC ®
Designed to measure surface temperatures in limited space. Bimetallic
sensor comes in close contact with surface to be measured, providing
a very fast response time. Made of stainless steel, they are rugged and
will hold calibration indefinitely unless mishandled. Dial face (3/4 inch)
and graduations are fired ceramic on stainless steel. An ancillary pointer
is held by a magnetic clutch and indicates the highest or lowest temperature reached in a given period. It withstands vibration and jarring of
normal use and can be reset indefinitely. Ideal for testing temperatures
of electronic parts as well as heat exchangers, circulating ovens, lab
heaters, hot plates, etc. NIST certification available upon request.
14-5003-01
14-5963-02
14-5903-03
14-5903-04
14-5903-05
14-5903-06
:
°+
0 to 250°F
0 to 5OO°F
50 to 750°F
0 to 135°C
0 to 275°C '
10 to 4OO°C
Sub~:
dr. ~ ~
2°
5°
10 °
5°
5°
5°
hock
43.73
43.73
43.73
43.73
43.73
43.73
14-5695
THERMOMETERS - TANK, SCOOP-MASTER
One piece non-sparking cup-case molded out of a smooth, black,
heat and chemical resistant plastic. The cup capacity of 120 mL
meets with API and ASTM requirements. The scale is engraved on the
tube for greater accuracy. The permanently etched thermometer
tubes are furnished in Yellow Lens tubing for easier reading. Tube is
held in place by spring clips, and can be replaced without tools.
Overalllength, 355 mm.
Cat.
No.
Complete
14-5695-01
14-5605-02
14-5695-03
14-5695-04
14-5695-05
14-5695-06
14-5695-07
14-5695-08
Range,
°F/oC
Div.,
°F/°C
ASTM
No.
Each
-30 to 120°F
0 to 180°F
20 to 220°F
176 to 500°F
-34 to 49°6
-18 to 82°C
-7 to 105°C
77 to 260°C
1.O°F
1.0°F
1,0°F
20%
0.5°C
05°C
0,5°C
1.0°6
58F
59F
130F
60F
58C
59C
130C
60C
75.66
75.60
75,60
83.66
75.60
75.60
75.60
83.66
Cat.
No.
1174
Each
21.42
21.42
25.30
34.44
21.42
21.42
25.30
34.44
BACK
The 355 mm long cases are made form hardwood that is lacquered
to prevent absorption of the sample. The 100 mL capacity brass cup
is non-sparking. Thermometers are identical with those supplied with
14-5695 Seoopmaster, and are similarly mounted with easily
maneuverable spring clips.
14-5696-01
-30 to 120°F
14-5696-02
0 to 1800F
14-5696-03
20 to 220°F
14-5696-04
170 to 500°F
14-5696-05
-34 to 49%
14-5696-06
-18 to 82°C
14-5696-07
-7 to 105%
14-5696-08
77 to 260°C
Note: See 14-5700forrefills
ASTM
Noi
Replacement Thermometers- for 14-5695 and 14-5696
14-5700-01
-30 to 120°F
58F
14-5700-02
0 to 180%
59F
14-5700-03
20 to 220°F
130F
14-5700-04
170 to 50O°F
60F
14-5700-05
-34 to 49°C
58C
14-5700-06
-18 to 82%
59C
14-5700-07
-7 to 105°0
130C
14-5700-08
77 to 260%
600
14-5696
THERMOMETERS - TANK, W O O D
Range,
°F/°C
, ;Ely;,.
F/c:,
1.0°F
1.0°F
1.0°F
2.0°F
05°C
0.5°0
0.5°C
1.0+6
RSTm
~ NO
58F
59F
130F
60F
580
59C
130C
60C
+ Each
70.56
70.56
70.66
79.48
70.56
70.56
70.58
79.48
14-5936
THERMOMETERS - WEATHERING TEST
Precision thermometers manufactured according to specifications of
the California Natural Gas Association for weathering tests of fabrics
and other materials.
Cat.
No.
14-5936-01
14-5936-02
Range,
OF
0 to 45
-70 to 0
Suhdiv., Length, Immersion,
°F
mm
mm
0,2
0.5
395
345
37
115
Each
31.18
62.37
THERMOMETERS
rIMER
22-3040
HYGROMETER/THERMOMETER
- DIAL
22-3468
Provides humidity and temperature readings in an easy-to-read dJal
format. Large 6-inch diameter analog face displays 0 to 100% relative
humidity and temperature from -40 ° to 122°F (-40 ° to 50°C).
Temperature resolution is 1° and accuracy is _+1.5%. Humidity
resolution is 1%RH and accuracy is _+2.5% at 5O%RH. Ideal for
constantly monitoring labs, hallways, walk-ins, storage facilities, and
plant areas. Self-contained unit is stable, accurate and requires no
adjustment or maintenance. Supplied complete with screw for wall
mounting. Size is 6-inch diameter x 1 inch and weight is 8 ounces.
Cat
:
22-3040-01
:
:
:
Each
Dial Hygrnmeter/Therrnometer
71.22
CLOCKS - ELECTRIC, 2 4 H O U R ,
TYPE
LABORATORY
WALL
Clock has standard 12 hour black numbered outer dial with inner ring
of balance of 24 hours in red. White background. Clear plastic lens.
Diameter of dial, 12 inches. Housed in slim, 2 V2 inch deep case.
Available in quartz or regular 120 volts, 60 Hz, AC. UL listed. Quartz
clocks require one "AA" battery (not supplied).
Cat,
NQ
22-3468-02
22-3468-04
Dial dia.,
Type
Reg electric
Quartz
ini
12
12
Eech
44.78
55.78
ELECTRIC STOP TIMERS
THERMOMETER RACKS
22-3710
14-4375
THERMOMETER
T I M E R - KWIK-SET, L A B - C H R O N ,
RACK - POLYPROPYLENE
Suitable for holding up to 25 thermometers in the correct vertical
position, thus avoiding mercury separation, which often occurs when
thermometers are improperly stored. Manufactured from V4 inch
polypropylene, the rack is sturdy and will not tip. Sides have large
comfortable carry handles. The top and middle plates have 5/~6 inch
hole diameters. The bottom plate has convenient V8 inch diameter
drain holes. Overall dimensions are 8 x 10 x 5 3/4 inches deep. The
entire rack is steam autoclavable.
Cat;:
N~
14-4875-01
:
:
Descr ptlod
~::~
:
Thermometer Reck
:
::
Each,
LAB-LINE
Unit features a high torque, synchronous motor which assures
consistent accuracy regardless of voltage fluctuations or line load.
The large, illuminated timing switch requires only a light touch for
operation. Pushbutton reset instantly returns all numbers to zero;
electric brake. Steel housing is finished in baked enamel and
measures 7 x 4 x 4 inches high. With 6 foot, 3-wire cord and plug.
15-month warranty. For operation on 120 volts, 60 Hz, AC, 30 watts,
Cat.
No
22-3710-D1
T merrange
Dial divisiQa$
EaCh
To gggg.g seconds
0.1 second
311.85
30.95
1175
TENSIOMETERS
c0
22-2840
TENSIOMETER - PRECISION, D U N O U Y , CSC
22-2845
TENSIOMETER - INTERFACIAL, D U N O U Y , CSC
Similar to 22-2840 except has graduated dial which reads in both
directions from zero and a double vernier is provided. The two scales
and corresponding verniers are different colors to indicate upward or
downward measured force. The 6 cm ring and its supporting frame
are made of platinum-iridium wire and welded, includes metal case
and instructions. Weighs 27 pounds.
: :
22-2845-51
Each
Interfacial Tensiometer
4005.75
TENSIOMETER REPLACEMEf,ITS/ACCESSORIES - FOR 22-2845-01
The 6 cm replacement platinum-iridium tensJometer ring has stirrup
with parallel sides that are 25 mm high to permit the ring to be used in
upward and downward interfacial measurements as well as surface
tension measurements. Mean circumference is approximately 6 crn
indicated to 3 significant figures, and is marked with the ratio of the radii
of the ring and cross section of the wire. Packed with stirrup in a
protective container.
Adjustable ring alignment joint is used for easy and rapid leveling of
ring. Joint is slipped into the socket of the vertical limb of the tensiometer and then the ring is inserted into the socket of the joint. Joint allows
the plane of the ring to be adjusted parallel to the surface of the liquid.
22-2848-01
Steel Torsion Wire, pkg/3
22-2847-01 6 cm Platinum-Iridium Tensiometer Ring
22-2848-01
Ring Alignment Joint
22-2841
~ ii! [a(h;
22.85
395.70
138.60
Provides precise readings of upward interracial and surface tensions
by the ring method to values reproducible within -+0.05 dyne/era.
This instrument is specified for determining interfacial tension of oil
against water by the ring method in ASTM D97t and solutions of
surface-active agents in ASTM Dt331. It is also specified for testing
synthetic rubber lattices in ASTM D1417 and determining the surface
tension of industrial water and wastewater in ASTM D1590.
Completely assembled with torsion wire and platinum-iridium ring.
Includes metal case and instructions. Weighs 27 pounds.
Cal.
No.
22-2840-01
Descriplien
3375.00
TENSIOMETER REPLACEMENTS/ACCESSORIES-FOR 22-2840-01
The 4 cm platin um-irtdium tensiometer ring makes all surface tension
measurements when used in conjunction with 22-2840 Tensiometer.
It has a mean circumference of approximately 4 cm indicated to 3
significant figures, and is marked with the ratio of the radii of the ring
and cross section of the wire. The replacement 6 cm platinum-iridium
tensiometer ring has stirrup with parallel sides that are 25 mm high to
permit the ring to be used in upward interracial as well as surface
tension measurements. Mean circumference is 6 cm. Both are packed
with stirrup in a protective container.
Cat.
No.
22-2841-01
22-2842-01
22-2842-02
Description
Each
Steel Torsion Wire, pkg/3
16.00
4 cm Platinumdridium Tensiometer Ring 393.75
6 cm Platinum-iridium Tensiometer Ring 393.75
SEE OUR BALANCE ACCESSORIES
Balance Tables, Balance Weights, Forceps, Weighing Boats,
Weighing Dishes, Weighing Funnels, Weighing Papers
1148
Each
Precision Tensiometer
THERMOMETERS
ASTM THERMOMETERS
.l:z
14-5010
ASTM
THERMOMETERS
The liquid-in-glass thermometers in this listing conform to ASTM E 1 specifications and also to current Institute of Petroleum specifications
for accuracy, materials and construction. All thermometers have serial numbers, and therefore are traceable to NIST specifications. Etched
scales and numerals have pigments that are specially selected for permanency and resistance to common solvents.
,NG. :
:
14-5010-81
14-5012-01
14-5014-01
14-5016-01
14-5018-01
14-5020-01
14-6022-01
14-5024-01
14-5026-01
14-5025-01
14-5030-01
14-5032-01
14-5034-01
14-5036-01
14-5038-01
14-5040-01
14-5042-01
14-5044-01
14-5046-01
14-5048-01
14-5050-01
14-5052-01
14-5054-01
14-5056-01
14-5050-01
14-5060-01
14-5062-01
14-5064-01
14-5066-01
14-5068-01
14-5070-01
14-5072-01
14-5074-01
14-5076-01
14-5078-01
14-5080-01
14-5082-01
14-5084-01
14-5086-01
14-5080-01
14-5090-01
14-5092-01
14-5094-01
14-5096-01
14-5098-01
14-5100-01
14-5102-01
14-5104-01
14-5105-01
14-5106-01
14-5107-01
:
ASTM ~ ~
:
,
N~.:
:
: :
Descdptlan
1C
Partial Immersion
1F
Partia] Immersion
2C
Partial Immersion
2F
Partial Immersion
3C
Partial Immersion
3F
Partial Immersion
4C
Acid Heat
4F
Acid Heat
5C
Cloud and Pour
5F
Cloud and Pour
6C
Low Cloud and Poor
6F
Low Cloud and Pour
7C
Low Distillation
7F
Low Distillation
8C
High Distillation
8F
High DistilLation
9C
Pensky-Martens (Low)
9F
Pensky-Martens (Low)
10C
Pensky-Martens (High)
1OF
Pensky-Martens (High)
11C
Cleveland Open Flash
11F
Cleveland Open Flash
12C
Density (Wide Range)
12F
Density (Wide Range)
13C
Loss on Heat
14C
Paraffin Wax Melting Point
14F
Paraffin Wax Melting Point
15C
Low Softening Point
15F
Low Softening Point
16C
High Softening Point
16F
High Softening Point
t7C
Saybo[t Viscosity
17F
Saybolt Viscosity
16C
Saybolt Viscosity
18F
Saybolt Viscosity
19C
Saybolt Viscosity
tgF
Saybolt Viscosity
2OC
Saybolt Viscosity
20F
Saybolt Viscosity
21C
Saybott Viscosity
21F
Saybolt Viscosity
22C
Oxidation Stability
22F
Oxidation Stability
23C
Engler Viscosity
24C
Engler Viscosity
25C
Engler Viscosity
26C Stabgity Test of Soluble Nitrocellulose
270
Turpentine Distillation
28C
Kinematic Viscosity
28F
Kinematic Viscosity
29C
Kinematic Viscosity
Scde
~
renge
-20 to 150°C
0 to 3020F
-5 to 300°C
20 to 580°F
-5 to 400°C
20 to 760%
-1 to 105°C
30 to 220%
-38 to 50°C
-36 to 1200F
-80 to 20°C
-112 to 7g°F
-2 to 3OO°C
30 to 580°F
-2 to 400°D
30 to 760°F
-5 to 110°C
20 to 230°F
90 to 370°C
200 to 7OO°F
-6 to 400°C
20 to 760°F
-20 to 102%
-5 to 215°E
155 to 170°C
38 to 82%
100 to 180°F
-2 to 80°C
30 to 180°F
30 to 20O°C
85 to 392°F
19 to 27%
66 to 80°F
34 to 420C
94 to 108°F
49 to 57°C
120 to 134°F
57 to 65°C
134 to 148°F
79 to 87°C
174 to 158%
95 to 1030C
204 to 2180F
18 to 28°C
39 to 54°C
95 to 105°0
130 to 1400C
147 to 102°0
36.6 to 39.4%
97.5 to 102.5°F
52.6 to 55.4°C
Subdivisions
10°C
2.00F
1.0%
20°F
1.0%
2.0°F
0.5°C
1.0°F
I.O°C
2.0%
10°C
2.00F
1.0°C
2.0°F
1.0°C
2.0°F
0.5°C
1.O°F
2,O°C
5O°F
2.0°C
60°F
0.2%
0.5°F
0.5°C
0.1°C
O.2°F
0.2°C
O.5°F
O.5°C
I.O°F
O.t°C
O.2°F
0.1°C
0.2°F
O.I°C
O.2°F
0.1°C
O.2°F
0.1%
O.2°F
O.l°C
0.2°F
0,2°0
O.2°C
02°C
0.1°C
0.5%
O.05°C
O.l°F
O.05°C
Length,
:
mm , mmhrslen
Each
322
76 mm
22.23
322
76 mm
23.31
390
76 mm
28.76
390
76 mm
23.36
415
76 mm
34.87
415
76 mm
52.89
381
152 mm
31.69
381
152 mm
31.09
230
108 mm
24.81
230
108 mm
20.41
230
76 mm
30.83
230
76 mm
34.74
385
Total
29.61
385
Tota~
29.59
385
Total
34.89
385
Total
30.29
290
57 mm
25.54
290
57 mm
27.71
290
57 mm
33.19
290
57 mm
33.19
310
25 mm
82.79
310
25 mm
32.79
420
Tota~
38.96
420
Total
35.59
155
Total
55.07
375
79 mm
52.39
375
79 mm
41.60
395
Total
32.67
395
Total
32.57
395
Total
85.36
395
Total
35.36
275
Total
28.31
275
Total
28.29
275
Total
26.95
275
Total
26.96
275
Total
26.95
275
Total
26.96
275
Total
27.03
275
Total
25.81
275
Total
25.81
275
Total
81.00
275
Total
28.91
275
Total
26.94
212
90 mm
44.50
237
90 mm
44.50
212
90 mm
68.21
463
Total
66.21
301
76 mm
57.61
305
Total
120.96
305
Total
104.96
305
Total
120.90
(continued on next page)]
] 49
THERMOMETERS
A S T M THERMOMETERS
(continued from previous page)
Description
14-5108-01
14-5110-01
14-5112-01
14-5110-01
14-5118-01
14-5120-01
14-5122-01
14-5124-01
14-5128-01
14-5120-01
14-0130-01
14-5132-01
14-5134-01
14-5136-01
14-5138-01
14-5145-51
14-5141-01
14-5142-01
14-5143-01
14-5144-01
14-5145-01
14-5146-01
14-5147-01
14-5148-01
14-5149-01
14-5150-01
14-5151-01
14-5152-51
14-5154-01
14-5158-01
14-5150-01
14-5160-01
14-5164-01
14-5165-01
14-5166-01
14-5170-01
14-5172-01
14-5174-01
14-5176-01
14-5177-01
14-5178-01
14-5179-01
14-5180-01
14-5181-01
14-5182-01
14-5183-01
14-5184-51
14-5186-01
14-5190-01
14-5192-01
14-5194-01
14-5196-01
14-5198-01
14-5200-01
14-5202-01
14-5204-01
14-5206-01
14-5208-01
14-5210-01
14-5212-01
14-5214-01
14-5216-01
14-5218-01
14-5220-01
14-5222-01
14-5224-01
14-5225-01
14-5226-01
14-5227-01
1150
Scale
range
2gP
Kinematic Viscosity
127.5 to 132.5°F
35F
Kinematic Viscosity
207.5 to 212.5°F
31F
Reid Vapor Pressure
-30 to 120°F
330
Low Aniline Point
-38 to 42°C
33F
Low Aniline Point
-36,5 to 107.5°F
340
Medium Aniline Point
25 to 105°C
34F
Medium Aniline Point
77 to 221°F
35C
Aniline Point
90 to 170°C
35F
Aniline Point
194 to 338°F
360
Titer Test
-2 to 68°C
370
Solvents Distillation
-2 to 52°0
380
Solvents Distillation
24 to 78°C
390
So~vents Distillation
48 to 102°C
400
Solvents Distillation
72 to 126°C
41C
Solvents Distillation
98 to 152°C
420
Solvents Distillation
95 to 255°C
430
Kinematic Viscosity
-51.6 to -34°C
43F
Kinematic Viscosity
-61 to-29°F
440
Kinematic Viscosity
18.6 to 21.4%
44F
Kinematic Viscosity
66.5 to 71.5°F
450
Kinematic Viscosity
23.6 to 26.4°C
45 F
Kinematic Viscosity
74.5 to 79.5°F
460
Kinematic Viscosity
48.5 to 51.4"0
46F
Kinematic Viscosity
119.5 to 124.5°F
470
Kinematic Viscosity
58.5 to 61.4°C
47F
Kinematic Viscosity
137.5 to 142.5°F
480
Kinematic Viscosity
80.6 to 83.4°C
48F
Kinematic Viscosity
177.5 to 182.5°F
490
Stormer Viscosity
20 to 70°C
50F
Gas Calorimeter Inlet
54 to 101°F
51F
Gas Calorimeter Outlet
69 to 116°F
52C
ButadieneBoiling Point Range
-10 to 5°0
530
BenzeneFreezing Point (1969)
-0.6 to 10.4°C
540
Congealing Point
20 to 100.6°0
54F
Congealing Point
68 to 213°F
560
Bomb Calorimeter
19 to 35°C
56F
Bomb Calorimeter
66 to g5°F
570
Tag Closed Tester Low Range
-20 to 50°0
57F
Tag Closed Tester Low Range
-4 to 122°P
580
Tank Low
-34 to 49%
58F
Tank Low
-30 to 120°F
590
Tank Medium
-18 to 82°C
59F
Tank Medium
0 to 180°F
600
Tank High
77 to 260°C
60F
Tank High
170 to 500°F
- Case w/Cup only for all "Tank"Thermometers
610
Petrolatum Melting Point
32 to 127°C
61F
Petrolatum Melting Point
90 to 260°F
620
Precision*
-38 to 2°C
030
Precision*
-8 to 32°C
640
Precision*
25 to 55°C
650
Precision*
50 to 8O°C
660
Precision*
75 to 105°C
670
Precision*
95 to 155°C
680
Precision*
145 to 205°C
690
Precision*
195 to 305°C
700
Precision*
295 to 405%
62F
Precision*
-36 to 35°F
63F
Precision*
18 to 09°F
64 F
Precision*
77 to 131°F
65F
Precision*
122 to 176°F
66F
Precision*
107 to 221°F
67F
Precision*
203 to 311°F
68F
Precision*
293 to 401%
69F
Precision*
383 to 501°F
70F
Precision*
563 to 761%
710
Oil in Wax
-37 to 21°C
71F
Oil in Wax
-35 to 70°F
72C
Kinematic Viscosity
-19.4 to -16.6°C
Subdivisions
Length,
mm
0.1%
0.1°P
1.5°F
0.2°C
0.5°F
0.2°C
O.5°F
5.2%
5.5%
0.2°C
0.2°C
0.2%
0.2°C
0.2%
0.2°C
0.5°C
0.1°C
0.2°F
0.05°C
5.1%
0.55%
O.I°F
0.05%
0.1°F
0.05°C
O,l°F
0,0500'
O.I°F
0.2%
0.1%
O.l°F
0.1°C
0.1%
0.2°C
O,5°F
O.O2°C
O.05°F
0.5%
1.0°F
0.5°C
1.O°F
5.5%
1.0°F
1.0°0
2.0°F
0.2°C
0.5°F
O.l°C
O.I°C
5.1°C
0.1°C
0,1%
O.2°C
0.2°C
0.5°C
O.5°C
O.2°F
5.2%
O.2°F
O.2°F
O,2°F
O,5°F
O.5°F
1.0°F
1.0°F
0.5°C
I.D°F
0.05°C
305
305
305
420
420
420
420
420
420
405
395
395
395
395
395
395
420
421
305
355
305
305
305
305
305
305
305
305
305
468
468
162
189
310
310
585
585
287
287
303
303
303
303
303
303
380
380
379
379
379
379
379
379
379
379
379
379
379
379
379
379
379
379
379
379
355
355
305
Immersion
Each
Total
120.06
Total
112.04
Total
21.40
50 rnm
43.59
50 mm
43.88
50 mm
43.58
50 mm
48,82
51 mm
46.21
51 mm
46.21
45 mm
48,54
100 mm
51.84
100 mm
51.04
100 mm
51.04
100 mm
01.94
100 mm
51.94
100 mm
51.04
Total
227.80
Total
207.69
Total
104.21
Total
104.14
Total
104.13
Total
104.13
Total
184.13
Total
104.13
Total
104.14
Total
104.14
Total
117.70
Total
104.14
65 mm
51.36
Total
81.51
Total
84.01
Total
57.14
Total
48.11
Total
50.93
Total
00.93
Total
153.64
Total
153.64
57 mm
26.41
57 mm
26.41
Total
21.69
Total
21.63
Total
21.63
Total
20,43
Total
28.09
Total
28.09
45.00
79 mm
39.89
79 mm
39.89
Total
184.74
Total
213.29
Total
263.47
Total
174.89
Total
201.21
Total
201.03
Total
236.64
Total
271.04
Total
307.04
Total
184,74
Total
108.99
Total
174.87
Total
174.87
Total
201.21
Total
210.70
Totot
232.76
Total
273.01
Total
307.04
76 mm
38.13
76 mm
30.13
Total
133.65
(continued on next page)
THERMOMETERS
ASTM THERMOMETERS (continued from previous page)
C~|~:
::
:
Stole
NQ,
14-5228-01
14-5229-01
14-5230-01
14-5231-01
14-5232-01
14-5234-01
14-5236-61
14-5238-61
14-5240-01
14-5242-01
14-5244-01
14-5246-01
14-5240-01
14-5250-01
14-5252-01
14-5254-01
14-5256-01
14-5258-01
14-5260-01
14-5262-01
14-5264-01
14-5266-01
14-5268-01
14-5270-01
14-5272-01
14-5274-01
14-5276-01
14-5278-01
14-5280-01
14-5282-01
14-5284-01
14-5286-01
14-5288-01
14-5290-01
14-5291-01
14-5292-01
14-5293-01
14-5294-01
14-5295-01
14-5296-01
14-5298-01
14-5300-01
14-5302-01
14-5304-01
14-5306-01
14-5308-01
14-5310-01
14-5312-01
14-5314-01
14-5316-01
14-5318-01
14-5319-61
14-5320-01
14-5322-01
14-5324-01
14-5326-01
14-5327-01
14-5328-01
14-5905-01
14-5910-01
14-5332-01
14-5333-01
14-5334-01
14-5335-01
14-5336-01
14-5337-01
14-5338-61
14-5339-01
14-5340-01
72F
Kinematic Viscosity
73C
Kinematic Viscosity
73F
Kinematic Viscosity
74C
Kinematic Viscosity
74F
Kinematic Viscosity
75F
Antifreeze Freezing Point
76F
Antifreeze Freezing Point
77F
Saybolt Viscosity
78F
Saybott Viscosity
79F
Saybolt Viscosity
80F
Saybolt Viscosity
81F
Saybolt Viscosity
82C
Fuel Rating, Engine
83C
Fuel Rating, Air
84C
Fuel Rating, Orifice, Tank
85C
Fuel Rating, Surge
86C
Fuel Rating, Mix
87C
Fuel Rating, Coolant
82F
Fuel Rating, Engine
83F
Fuel Rating, Air
84F
Fuel Rating, Orifice, Tank
85F
Fuel Rating, Surge
86E
Fuel Rating, Mix
87F
Fuel Rating, Coolant
88C
Vegetable Oil Flash
88F
Vegetable Oil Flash
89C
Solidification Point
9OC
Solidification Point
91C
Solidification Point
g2C
Solidification Point
93C
Solidification Point
94C
Solidification Point
95C
Solidification Point
96C
Solidification Point
97C
Tank
97F
Tank
98C
Tank
98F
Tank
99C
Weathering Test
99F
Weathering Test
_
Non-sparking Armor for Above
100C
Solidification Point
101 C
Solidification Point
102C
Solvents Distillation
103C
Sofvents Distigation
104C
Solvents Distillation
105C
Solvents Distillation
106C
Solvents Distillation
107C
Solvents Distillation
108F
Saybolt Viscosity
109F
Saybolt Viscosity
110 C
Kinematic Viscosity
11 OF
Kinematic Viscosity
111C
Tar Acids Distillation
112C
Solidification Point Benzene
113C Softening Point (Bitumen) Wide Range
!13F Softening Point (Bitumen) Wide Range
114C
Aviation Fuel Freezing Point
1 t 5CU
BeckmanDifferential Upward
115CD
BeckmanDifferential Downward
116C
Bomb Calorimeter
117C
Bomb Calorimeter
1 t 8C
Kinematic Viscosity
118F
Kinematic Viscosity
119C
Antifreeze Freezing Point
119F
Antifreeze Freezing Point
t 2gc
Kinematic Viscosity
121 C
Kinematic Viscosity
122C
Brookfiefd Viscosity
-2.5 to 2.5°F
-41.4 to -38.6°C
-42.5 to -37.5°F
-55.4 to -52.6°C
-67.5 to -62.5°F
-35 to 35°F
-65 to 5°F
245 to 265°F
295 to 315°F
345 to 365°F
395 to 415°F
445 to 465°F
-15 to 105°C
15 to 7O°C
25 to 80°C
40 to 150°C
95 to 175°C
150 to 205°C
0 to 220°F
60 to 160°F
75 to 175°F
100 to 300°F
200 to 350°F
300 to 400°F
10 to 209°C
50 to 392°F
-20 to 10°C
0 to 30°C
20 to 50°C
40 to 70°C
60 to 90°C
80 to 110%
100 to 130°C
120 to 150°C
-18 to 49°C
0 to 1BO°F
16 to 82°C
60 to 180°F
-50 to 5°C
-55 to 40°F
145 to 205°D
195 to 305°C
123 to 177°C
148 to 202°C
173 to 227°C
198 to 252°C
223 to 277°C
248 to 302°C
270 to 290°F
320 to 340°F
133.6 to 136.4°C
272.5 to 277.5°F
170 to 250°C
4 to 6°C
-1 to 175°C
30 to 350°F
-80 to 20°C
0 to 6°C
6 to O°C
18.9 to 25.1°C
23.9 to 30.1°C
28.6 to 31.4°C
33.5 to BS.5°F
-38.3 to -30°C
-37 to -22°F
38.5 to 41.5°C
98.5 to 101.4°C
-45 te -35°C
Sub:divisions
0.1°F
O.05°C
0.1°F
O.05°C
Olt°F
O.5°F
O.5°F
O.5°F
O.5°F
O.5°F
O.5°F
O.5°F
1.0°C
1.0°C
1.0°C
1.0°C
1.0°C
I.O°C
2.0°F
t.O°F
1.0°F
2.O°F
2.O°F
I.O°F
1.0°C
2.0°F
O.I°C
O.I°C
B.I°C
0.1°C
0.1°C
0.1%
0.1%
O.I°C
g.5°C
1.0°F
B.5°C
1.0°F
0.20C
O.5°F
O.2°C
0.5°C
0.2°C
O.2°C
0.2°C
O.2°C
O.2°C
0.2°C
O.5°F
g.5°F
0.05%
B.I°F
0.2°C
O.O2°C
0.5°C
1 .g°F
0.5°C
O.Ol°C
001°C
O.Ol°C
B.Ol°C
0.05°C
01°F
0.1°C
O.2°F
O.05°C
005°C
O.I°C
Length
~ mm
305
305
305
305
305
408
408
275
275
275
275
275
162
171
383
310
167
172
162
171
383
310
167
172
287
267
370
370
370
370
370
370
370
370
303
303
303
303
302
302
*
370
370
395
395
395
395
395
395
275
275
305
305
395
215
405
405
300
640
640
609
609
305
305
420
420
305
305
300
Each
Total
121.24
Total
234.70
Total
234.71
Total
256.09
Total
225,71
,~m
100 mm
60.23
100 mm
180.86
Total
38.13
Total
44.62
Total
38.13
Total
44.62
Total
44.62
30 mm
33.90
40 mm
33,96
249 mm
35.43
181 mm
35.41
35 mm
40.49
40 mm
40.49
30 mm
33.96
40 mm
33.96
249 mm
33.43
181 mm
35.41
35 mm
40.40
40 mm
40.49
57 mm
38.51
57 mm
33.51
76 mm
80.21
76 mm
48.04
76 mm
46.26
76 mm
47.73
76 mm
47.73
76 mm
47.73
76 mm
46.83
76 mm
48.34
Total
27.13
Total
27.13
Total
27.13
Total
27.13
35 mm
132.30
35 mm
150.31
35.00
76 mm
46.21
76 mm
53.71
100 mm
51.81
100 mm
31.84
100 mm
51.83
100 mm
49.64
100 mm
51.07
100 mm
54.13
Total
37.91
Total
36.14
Total
120.54
Total
120.54
100 mm
97.03
Total
97.03
Total
36.60
Total
36.80
Total
38.70
Total
454.30
Total
420.00
Total
201.80
Total
201.80
Total
102.69
Total
223.50
100 mm
211.68
100 mm
223.50
Total
103.27
Total
115.21
Total
115.21
(continued on next page)
1151
qr.n
THERMOMETERS
ASTM THERMOMETERS (continued from previous page)
Scale
SubLength,
,..
divisions
m
14-5342-01
123C
Brookfield Viscosity
-35 to -25°C
8.1°C
300
14-5344-01
124C
Brookfield Viscosity
-25 to -15°C
0.1°0
300
14-5346-01
125C
Brookfield Viscosity
-15 to -5°C
0.1°0
300
14-5348-01
126C
Kinematic Viscosity
-27.4 to -24.6°C
8.05%
305
14-6549-01
126F
Kinematic Viscosity
-17.5 to -12.5°F
O.I°F
305
14-5356-61
1270
Kinematic Viscosity
-21.4 to 18.6%
0.05°C
305
14-5352-61
1280
Kinematic Viscosity
-1.4 to 1.4%
0.05°C
305
14-5353-01
123F
Kinematic Viscosity
29.5 to 34.5°F
0.1°F
305
14-5364-01
t29C
Kinematic Viscosity
91.6 to 94.4%
0.05°0
305
14-5355-01
129F
Kinematic Viscosity
197.5 to 202.5°F
O.I°F
305
14-5356-01
1300
Tank
-7 to 105°0
9.5°0
303
14-5357-01
t30F
Tank
20 to 220°F
1.0°F
303
14-5356-01
f32D
Kinematic Viscosity
148.6 to 151.4°C
0.08°C
305
* Thermometer sets available for 62-78C and 62-701:, see 14-4665. MERCURIAL THERMOMETERS
14-466e
THERMOMETER SET - ASTM, PRECISION, CALIBRATED
These sets of thermometers cover the range from -38 to 405°C or
-36 to 761°E Each set consists of 9 thermometers in a felt-lined
leatherette case, Each thermometer has been calibrated against NIST
standards and comes with a calibration document showing corrections to the nearest tenth of a scale division traceable to NIST. Each
incorporates the ice point (0% or 32°F) as a reference point. This
enables the user to validate and update the calibration document, to
insure accurate measurements over the life of the thermometer. Each
set contains nine ASTM thermometers Nos. 62-70C or 62-70E
14-4665-01
ASTM Nos. 62 - 700
2412.16
14-4665-02
ASTM Nos. 62 - 7OF
2412.16
Note:lndividualreplacementthermometers are also available
SEE OUR SELECTION
OF APPARELAprons, Boot/Shoe Covers,
Coats/Smocks, Coveralls,
Hoods/Head Covers, Sleeves
1152
Immersion
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Total
Each
115.21
115.21
115.21
151.60
151.60
151.60
127.30
127.30
119.00
119.00
34.96
34.98
119.00
REUNITING SEPARATEDMERCURYCOLUMNS*
The largestsingle causefor the failure of precisionthermometers in the lab is
due to separated mercury columns. This can occur in transif or in the lab. The
life of the instrument can be greatly extended if the following proceduresare
rigidly employed. Other methods may cause damage to the thermomete~
A. COOLINGMETHOD:
With the thermometerin an updght position gradually immerse ONLYthe bulb
in a solution of solid CO (Dry-Ice) and alcohol so that the mercury column
retreatsslowly into the butb. Do not cool the stem or mercury column. Keepthe
bulb in the solution until the main column as well as the separated portion
r~re~s into the bulb. Removeand swing thermometer in short arc forcing all
the mercury into the bulb. Most mercury thermometerscan be reunited using
this method regardless of range (with the exception of deep immersion thermometere) provided ONLYTHE BULB is immersed in the CO2
CAUTION:
1. Do not touch the bulb until it has warmed sufficiently for the mercury
to emerge from the bulb into the capillary.
2. Never subject the stem or mercury column to the CO solution as it will
freezethe mercury column in the capillaryand may causei~e bulb to fraofure.
B. HEATING METHOD:
This method applies to thermometers with a maximum range of 260% or
500°F, equipped with expansion chambers sufficiently large to accommodate the separ~ion plus a portion of the main column. Immerse as much of
bulb AND STEMas possible in a large beakercontaining a liquid whose flash
point is well abovethe highest indication of the thermometer being reunifed.
Heat the beakerstirring the liquid with the thermometer until the separation
and a portion of the main column enter the chambe~ Tap thermometer in
palm of gloved hand reuniting column. Allow to cool slowly.
CAUTION:
1. Never use open flame on bulb.
2. Never fill expansion chamber more than 2/3 full.
3. Make certain Flash Point of liquid is well above highest temperature
ndicated on the thermometer.
4. Thermometers WhOSe ranges exceed 260"0 or 500°F CAN NOT be
reurereo using heat without damaging the instrument.
*Courtesy of Ever Ready Thermometer Co., Inc.
THERMOMETRIC INFORMATION
Formulae for conversion of thermometer scales:
Degrees C =
(Degrees F - 32) x 5
9
Degrees F =
(Degrees C x 9) + 32
5
Emergent stem correction (for total immersion mercury thermometers):
Correction °C = 9.00016 n (T-t)
Correction °F = 0.00009 n (T-t)
n = The number o1 degrees of emergent mercury column.
T = bulb temperature.
[ = Mean temperature of emergent column.
THERMOMETERS
LAB GRADE
THERMOMETER
THERMOMETERS - YELLOW BACK, CELSIUS,
MERCURIAL, LAB GRADE
14-4380, 14-4385
Made of seasoned normal glass tubing with yellow background.
Scale is engraved on the stem which is 6 to 7 mm in diameter.
Tolerances are within those set by NIST (NBS). Feature non-roll
fittings; permanent markings; vertical numerals; toughened bulbs
and safe-seal packaging.
Cat,
Na
i:
:
Total Immersion
14-4465-01
14-4465-02
14-4465-93
14-4465-04
14-4465-05
Range
"C
:
:
Sub- "
div,~ :
LeRgth,
mm
:
Each
-35 to 50
-20 to 110
-20 to 150
-10 to 260
-10 to 400
1
1
1
1
2
305
305
305
405
405
11.65
11.23
11.55
16.43
19.63
76 mm Immersion
14-4470-01
-35 to 50
14-4470-02
-20 to 110
14-4470-03
-20 to 150
14-4470-04
-10 to 260
14-4470-05
-19 to 400
1
1
1
1
2
305
305
395
405
405
11.55
11.23
11.55
15.43
19.63
Cat~
Ha;
R~ga
C
Total Immersion
14-4380-01
-35 to 50
14-4380-02
-20 to 110
14-4380-03
-20 to 150
14-4380-04
-10 to 260
14-4380-05
-10 to 400
14-4380-06
-10 to 500*
76 mm Partial Immersion
14-4381-01
-35 to 50
14-4381-62
-20 to 110
14-4331-03
-20 to 150
14-4381-64
-10 to 260
14-4381-05
-10 to 400
14-4381-06
-10 to 500*
*White back borosilicate glass
S.~
dlv.
Length,
mm :
305
305
305
405
405
405
23.90
23.90
28.90
32.30
38.60
96.60
1
1
1
1
2
2
305
305
305
405
405
405
23.90
23.90
23.90
32.30
38.60
96.60
THERMOMETERS - YELLOW BACK, FAHRENHEIT,
MERCURIAL, PRECISION GRADE
Like 14-4465, 14-4470 but Fahrenheit.
Cat;
No.
:
Total Immersion
14-4510-01
14-4516-02
14-4510-03
14-4510-04
14-4510-05
°FR"g
e
Sub" :
dlv,°
Length,
rnm
Each
-30 to 120
0 to 230
0 to 300
20 to 500
20 to 750
1
2
2
2
5
305
305
305
405
495
11.55
11.23
11.55
15.43
19.63
76 mm Immersion
14-4515-01
-30 to 120
14-4515-02
0 to 230
14-4515-03
0 to 300
14-4515-04
20 to 560
14-4516-05
20 to 750
1
2
2
2
5
305
305
305
405
405
11.55
11.23
11.23
15.43
19.63
PRECISION
GRADE
THERMOMETERS
The general purpose glass laboratory thermometers in this listing
have been selected for specifications approved by the Scientific Apparatus Makers' Association in conjunction with the National Institute of
Standards and Technology (NIST) formerly the National Bureau of
Standards (NBS). They have been approved by Subcommittee V of
ASTM E26-05 and also meet American National Standard Institute
(ANSI) specifications. All thermometers listed are made from the
finest thermometric glass available for strength, clarity and thermal
sensitivity. Each is individually pointed at close intervals to assure
accuracy over the entire range and has its own individual serial
number. Partial immersion thermometers are calibrated (unless otherwise stated) for 76 mm immersion, measured from the bottom o1
the bulb. Nitrogen filled; suspension ring.
Range
°F
Each
1
1
1
1
2
2
THERMOMETERS - YELLOW BACK, FAHRENHEIT,
MERCURIAL
Cah
Noi
(.n
THERMOMETERS - YELLOW BACK, CELSIUS,
MERCURIAL, PRECISION GRADE
Sub,
dtv.°
Length,~ . . . . . . . .
ram.
Each
Total Immersion
14-4385-01
-30 to 120
1
14-4385-02
O to 230
2
14-4385-03
O to 300
2
14-4385-04
20 to 500
2
14-4365-05
20 to 750
5
14-4385-06
20 to 930*
5
76 mm Partial Immersion
14-4386-01
-30 to 120
1
14-4386-02
O to 230
2
14-4386-93
0 to 300
2
14-4386-04
20 to 500
2
14-4366-05
20 to 750
5
14-4386-06
20 to 930*
5
*Available in white back borosilicate glass only
THERMOMETERS - PRECISION, DOUBLE
MERCURIAL, 7 6 M M IMMERSION
305
305
305
405
405
405
23.30
23.50
23.30
32.30
38.60
96.90
305
305
305
405
405
405
23.60
23.90
23.90
32.30
38,60
66.90
SCALE,
Similar to 14-4381 series, except read in Celsius and Fahrenheit. Stems
are 6 to 7 mm O,D. and bulbs do not exceed stem diameter. Nitrogen
rests above the mercury, 14-4556-01 is 305 ram; others, 405 mm long.
Tops are finished with suspension rings.
Cot;
9nnge,
NO; :
C
14-4556-01 -20 to 110
14-4556-02 -10 to 260
14-4556-03 -10 to 400
THERMOMETER ARMORS
Range,
°F
0 to 230
20 to 500
20 to 750
sabdivv Subd!v.,
%
°F
Each
1
2
25.66
1
2
35.19
2
5
42.10
Thermometer armors only, made from heavy brass tubing, and nickel
plated. With top suspension ring on the screw cap. Suitable for use with
14-4380 to 14-4556 thermometers.
cat;
~
Na~
14-4576"30
14-4576-35
"
Forthermometer:
length,In
12
16
Each
12.00
15.43
1153
THERMOMETERS
14-4650
~1~
THEPJ~OMETERS - YELLOW BACK, MERCURIAL,
FRACTIONAL DEGREE, PRECISION GRADE
14-4855
These fractional degree thermometers have an 0.D. of 6 to 7 ram.
Bulbs do not exceed stem diameters, Nitrogen rests above mercury.
Totallmmersion-Celsius
14-4659-92
-1 to 51
14-4659-93
-1 to 101
14-4650-04
-1 to 201
76 mm Immersion-Celsius
14-4655-92
-1 to 51
14-4655-03
-1 to 101
14-4655-04
- t to 201
01
0.1
0.2
460
510
610
68.40
84.60
93.60
0.t
0.t
0.2
460
610
610
6B.40
64.00
93.60
Totallmmersion-Fahrenheit
14-4650-12
-30 to 124
0.2
460
14-4650-13
-30 to 214
0.2
610
14-4550-14
-30 to 394
0.5
610
76 mm Immersion-Fahrenheit
14-4655-12
-30 to 124
02
450
14-4655-13
-30 to 214
0.2
610
14-4666-14
-30 to 394
0.5
610
Factory certified Thermometers traceable to NIST, available
quest. Contact your local sales office for information.
68.46
84.00
93.60
68.40
54.00
93.60
on re-
14-4845
THERMOMETERS - CELSIUS, ADJUSTABLE BUSHING,
ERT¢O
Thermometers have an adjustable bushing with a standard taper of 10/
18. A neoprene grommet at the top of the bushing permits the thermometer to slide through, allowing a variety of immersion lengths. Vapor
temperatures and liquid temperatures may be taken alternately without
dismantling equipment. The 6 inch immersion length can be used for
flasks from 250 to 3000 mL, and the 12 inch for flasks from 5000 to
22,000 mL. Subdivided into 1°C divisions. Stems are yellow backed for
good legibility. Individual serial number I.D. is on each thermometer.
14-4845-01
A
6
-10 to 250
56.80
14-4845-02
B
12
-10 to 250
76.66
14-4845-03
C
6
- t 0 to 380
64.15
14-4845-04
D
12
-10 to 360
78.64
THERMOMETER BUSHING
Glass bushing with a 10/18 standard taper for replacement in
14-4845 thermometer. Includes neoprene grommet.
14-4850-01
1154
Thermometer Bushing
23.52
THERMOMETERS - CELSIUS, • 1 0 / 3 0 , GROUND
JOINT, YELLOW BACK, PRECISION GRADE
Available in 4 temperature ranges and 9 immersion lengths. The
graduations and figures are clearly etched and offer a sharp contrast
against the yellow background. Graduated in 1°C subdivisions. A
special type of construction eliminates the distortion of the bore
through the joint, and prevents the mercury column from separating
along the taper. Serialized to insure traceability.
76 mm Imme~on
14-4855-01
14-4855-92
14-4855-03
14-4855-04
100 mm Imme~ion
14-4855-05
14-4855-06
14-4855-07
14-4855-08
125 mm Immersion
14-4855-09
14-4855-10
14-4855-11
14-4855-12
150 mm Immersion
14-4855-13
14-4855-14
14-4855-15
14-4855.16
190 mm Imme~ion
14-4855-17
14-4855-18
14-4855-19
14-4855-20
216 mm Immersmn
14-4855-21
14-4855-22
14-4855-23
14-4855-24
250 mm Immersion
14-4855-25
14-4855-26
14-4855-27
14-4855-28
280 mm Immersion
14-4855-29
14-4855-30
14-4855-31
14-4856-32
Range,
-10°Cto °C
Each
110
150
250
360
41.33
44.86
49.79
49.96
110
150
250
360
44.86
49.74
49.51
49.74
110
150
250
360
49,74
49.51
49.77
49,50
110
150
250
360
49.77
50.17
52.29
54.30
110
150
250
360
59.17
52.26
54.31
55.66
110
150
250
369
59.95
59.95
62.89
65.73
110
150
250
360
63.52
65.62
66.88
71.19
110
150
250
360
72.34
73.92
76.33
81.06
THERMOMETERS
14-4856
THERMOMETERS - CELSIUS, TEFLON ® COATED,
~; 1 0 / 3 0 , G R O U N D JOINT, YELLOW BACK,
PRECISION GRADE
14-486S
Similar to the 14-4855 series with the added feature of Teflon® coating to protect against shock as well as contamination in the event of
accidental breakage. The entire instrument is coated with Teflon, with
the exception of the ground joint. Accurate to within NIST (NBS)
tolerances.
Cet
:
:
Range::
-lO'C
::
~
75 mm Immersion
14-4856-01
14-4856-02
14-4856-03
100 mm Immersion
14-4856-04
14-4856-05
14-4856-06
125 mm Imme~ion
14-4856-07
14-4856-08
14-4856-09
150 mm Immersion
14-4856-10
14-4856-11
14-4856-12
190 mm Immersion
14-4856-13
14-4856-14
14-4856-15
215 mm Immersion
14-4856-16
14-4856-17
14-4856-18
250 mm Immerszon
14-4856-19
14-4856-20
14-4856-21
280 mm Immersion
14-4856-22
14-4856-23
14-4856-24
305 mm Immersion
14-4856-25
14-4856-26
14-4856-27
;:
(r.n
THERMOMETERS - LONG IMMERSION TYPE,
WITHOUT GROUND JOINT, YELLOW BACK
Mercury filled, yellow backed, etched stem, available in -10 to 250°C
and -10 to 360°C. Subdivisions on both ranges are 1°. Length of the
250% thermometers, exclusive of the immersion, is 11 inches; of the
360%, 12 inches. These thermometers can be used with the
thermometer adapters shown under 14-6900 to 14-6950.
;
i
:
-10 to 250°C
14-4865-22
14-4865-23
14-4865-24
14-4865-25
14-4865-26
14-4865-27
14-4865-28
14-4865-29
14-4865-30
4
5
6
7
8
g
10
11
12
41.47
43.57
45,36
47.77
48.51
50.29
51.13
55.44
56.38
-10 to 360°C
14-4866-22
14-4866-23
14-4866-24
14-4866-25
14-4866-26
14-4866-27
14-4868-28
14-4866-20
14-4866-30
4
5
5
7
8
9
10
11
12
43.57
45.04
44.70
50.92
52.71
56.17
58.90
60.16
60.16
110
150
250
45.36
48.30
52.39
110
150
250
49.14
50.40
53.13
110
150
250
50.08
58.02
55.96
110
150
250
55.96
57.22
59.43
116
150
250
59.53
61.42
64.89
110
150
250
67.72
67.72
70.56
THERMOMETERS - LOW TEMPERATURE, CELSIUS, RED
LIQUID FILLED, TOTAL IMMERSION
110
150
250
71.29
53.02
74.65
Made of solid thermometer tubing having a diameter of 6 to 7 mm
with expansion bulb and suspension ring. Liquid column is dyed red
to facilitate reading.
110
150
250
80.22
81.58
84.21
110
150
250
86.73
87.88
90.61
Renp
14-4700-01
14-4700-02
~
-100 to 50
-50 to 50
S U b - L e n g t h,
1
t
305
306
36.61
36.61
THERMOMETERS - CELSIUS, ~ 1 0 / 3 0 , GROUND
JOINT, WHITE BACK, ORGANIC FILLED, PRECISION
GRADE
Similar to the 14-4855 series but with colored spirit filling in place of
mercury.
Ca
NO.
14-4857-01
14-4857-02
14-4857-03
14-4887-04
14-4857-05
14-4857-06
14-4857-07
14-4857-08
:
;
Range,
%
-10
-10
-10
-10
-10
-10
-10
-10
to
to
to
to
to
to
to
to
110
150
110
150
110
150
110
150
Immersion,
m
76
76
100
tO0
125
125
150
150
:
Each
37.48
40.63
41.37
42.63
42.31
45.15
48.19
49.35
14-4780
THERMOMETER - LOW TEMPERATURE, CELSIUS,
ORGANIC FILLED, PRECISION GRADE
A total immersion thermometer filled with colored organic.
Approximate length is 350 mm. Range is -200 to +30°0. graduated
in 1° divisions.
cat.
:
~
:
14-4780-01
Low Temperature Thermometer
87.04
1155
THERMOMETERS
REPLACEMENT THERMOMETERS
Cat.
No.
14-4852
THERMOMETERS - TOTAL IMMERSION, YELLOW
BACK, RED LIQUID, ORGANIC FILLED, SAMA
PRECISION GRADE
Length is 305 mm. All thermometers are individually serialized.
:
i::
Sub,
Range
Each
14-4852-01
-20 to 110°C
1°C
25,09
14-4852-02
-20 to tSO°C
1%
25,09
14-4852-03
0 to 230°F
2°F
25.09
14-4852-04
0 1o 300°F
2°F
25.09
14-4852-05
35 to 50°C
1°C
08,57
14-4852-06
30 to 120°F
l°F
25.00
Range,°
Red Spirit Filled (For 14-4915)
14-4920-01
-30/120F
14-4920-02
+30/120F
14-4920-03
0/220F
14-4920-05
-35/50C
14-4020-06
-20/105C
Mercury Filled (For 14-4916)
14-4921-01
-30/120F
14-4921-02
+30/120F
14-4921-03
0/220F
14-4921-05
-35/50C
14-4021-06
-20/105C
SAFETY
25.09
25.09
25.09
27,30
25.09
25.09
25,09
25.09
14-4915
Available as red liquid filled or mercury filled. Cases are plated meta~
with pocket cJip. The metal tops in which thermometers are secured
have metal rings for suspension. Length is 165 ram, with toughened
bulb and permanent marking.
1156
~ Rng~
::
Sub-~
dlv.
:
THERMOMETERS - SAFETY, TEFLON ® COATED, YELLOW
BACK, MERCURIAL
These 76 mm immersion thermometers are sealed in an inert, transparent Teflon® jacket which absorbs shock and prevents shattering.
The jacket prevents contamination and also serves to retain the mercury and glass in case of breakage. Thermometers are 300 mm long.
All thermometers are serialized; accurate to NIST (NBS) tolerances.
Cat.
No~
Range
Sabdiv.
Each
14-4387-01
-20 to 110%
1°C
37.22
14-4387-02
-20 to 150°C
1°C
37.22
14-4387-03
-10 to 200°C
1°C
37.22
14-4387-11
60 to 260°C
1°C
42.00
14-4387-04
0 to 230°F
2°F
37.22
14-4387-05
0 to 300°F
2°F
37.22
14-4387-06
20 to 400°F
2°F
37.22
14-4387-12
140 to 500°F
2°F
42.00
THERMOMETERS - SAFETY, TEFLON ® COATED, WHITE
BACK, RED SPRIRIT FILLED
THERMOMETERS - POCKET, WITH METAL CASE
Ca
N~
Red Spirit Filled
14-4915-01
14-4915-02
14-4915-03
14-4915-05
14-4915-06
Mercury Filled
14-4916-01
14-4916-02
14-4916-03
14-4916-05
14-4916-06
17.74
17.74
17.74
17.74
17.74
14-4387
Similar to 14-4852 but 76 mm immersion. All Celsius thermometers
are in 1° divisions; all Fahrenheit thermometers are in 2 ° divisions.
Length is 305 mm.
-35 to 50°C
-20 to 110%
-20 to 150%
-10 to 200°C
-30 to 120°F
-O to 230%
0 to 300°F
20 to 400°F
17.74
17.74
17.74
17.74
17.74
THERMOMETERS
THERMOMETERS - PARTIAL IMMERSION, YELLOW
BACK, RED LIQUID, ORGANIC FILLED, SAMA
PRECISION GRADE
14-4853-01
14-4853-02
14-4853-03
14-4853-04
14-4853-05
14-4853-06
14-4883-07
14-4853-08
Each
Each
-30 to 120°F
+30 to 120°F
0 to 220°F
-35 to 50°C
-20 to 105%
2°F
l°F
2°F
1°C
1%
28.87
28,87
28.87
28.87
28.87
-30 to 120°F
+30 to 120°F
0 to 220°F
-35 to 50%
-20 to 105°C
2°F
I°F
2°F
1°C
1°C
25,41
28.87
28.87
25.41
25.41
Similar to 14-4387 except white back and red colored spirit filling.
Cat;
No.
14-4388-01
14-4388-02
14-4388-03
14-4388-04
14-4388-05
14-4388-06
14-4388-07
14-4388-08
14-4388-09
14-4388-10
Range.
-20 to 110%
-20 to 150%
-10 to 2000C
0 to 230°F
0 to 300°F
20 to 400°F
-50 to 50°C
-100 to 50%
-50 to 50°C
-100 to 5g°c
Subdi~
1°C
1°C
1%
2°F
2°F
2°F
t°C
1°C
1°C
t°C
Lenghl Immersian
nun
mm
Each
300
76
37.22
300
76
37.22
305
75
37.22
300
76
37.22
300
76
37.22
305
76
37.22
305
76
38.95
305
76
87.85
305
Total
38.95
305
Total
57.85
THERMOMETERS
DIAL-TYPE INDUSTRIAL THERMOMETERS
T
14-5432
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 2 1/2 INCH STEM
Industrial grade back-connected bE-metallic 3 inch diameter dial is ideal
for many applicatLons. Can be easily recalibrated with hex screw. Made
o1 18-8 type 304 stainless steel with all welded construction. Stern
diameter is r/4 with V2 inch NPT connection nut. Single scale in either
°F or %. Actuated by super-sensitive bE-metallic helix coil.
Bi-metallic element is dampened with silicone for minimum pointer
vibration and maximum heat transfer. Accuracry is _+1% around the
entire dial range. Dial is protected by extra heavy glass crystal Stern
should be immersed at least 2 inches in liquid and 4 inches in gases.
Length of stem is 2 ~/2 inches including threads, not suitable for gases.
Cat,
Temperatur~
NO~ :
:
Range,°
Subtly s ons;?
Each
14-5432-02
-40 to t60F
2
14-5452-03
25 to 125F
1
14-5432-04
0 to 220F
2
14-5432-06
50 to 300F
2
14-5432-07
50 to 400F
5
14-5432-08
50 to 500F
5
14-5482-09
150 to 750F
tO
14-5432-10
*200 to IO00F
10
14-5432-12
0 te 50C
0.5
14-5432-15
-10 to ltOC
1
14-5482-16
0 to 150C
1
14-5482-18
0 to 300C
5
*Not recommended for continuous use above 8OO°F
68,22
68.22
68.22
68.22
68.22
68.22
68.22
68,22
68,22
68.22
68.22
68.22
Similar to 14-5432, except with 4 inch stem. Length of stem is 4
inches including threads. Stern should be immersed at least 2 inches
in liquid and 4 inches in gases.
:
Temperaure
Range,~
: :
:
:SubdivisionS/'
14-5483-02
-40 to 160F
2
14-5433-03
25 to t25F
t
14-5433-04
0 to 220F
2
14-5433-06
50 to 300F
2
14-5433-07
50 to 400F
5
14-5453-08
50 to 500F
5
14-5433-09
150 to 750F
10
14-5438-10
*200 to 1000F
10
14-5433-12
0 to 50C
0.5
14-5483-15
-10 to ttOC
1
14-5433-16
0 to 150C
1
14-5433-18
0 te 30OC
5
*Not recommended for continuous use above 800°F
Similar to 14-5432 excem wltn 6-inch stem. Length of stem is 6
riches including [nraaas. Stem should be immersed at least 2 inches
in ilaUlO and 4 inches in gases.
Cat.
Temperature
No.
Range,°
Subdivisions,
°
Each
14-5434-02
-40 to 160F
2
63.22
14-5434-58
25 to 125F
1
68.22
14-5434-04
0 to 220F
2
68.22
14-5434-06
50 to 300F
2
68.22
14-5484-07
50 to 400F
5
68.22
14-5434-08
50 to 500F
5
68.22
14-5434-09
150 to 750F
10
68.22
14-5484-10
*200 to IO00F
t0
68.22
14-5434-12
0 to 50C
0.5
68.22
14-5434-15
-10 to 110C
t
68.22
14-5434-16
0 to 150C
1
68.22
14-5434-15
0 to 3000
5
63.22
Notes: * Not recommended for continuous use above 800°E
K~...
lh.~J
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, SACK-CONNECTED, 9 I N C H STEM
Similar to 14-5432, except with 9 inch stem. Length of stem is 9
inches including threads. Stem should be immersed at least 2 inches
in liquid and 4 inches in gases.
Cat,
NO.
14-5435-02
14-5435-03
14-5485-04
14-5435-06
14-5435-07
14-5435-08
14-5435-09
14-5435-10
14-5435-12
14-5435-15
14-5435-16
14-5485-18
Temperature
Range,Q -
Each
Subdivisions,°
-40 to 160F
2
68.22
25 to 125F
1
68,22
0 to 200F
2
68.22
50 to 300F
2
65.22
50 to 400F
5
68.22
50 to 500F
5
68.22
150 to 750F
10
68,22
*200 to IO00F
tO
58.22
0 to 50C
0.5
65.22
- 10 to tlOC
1
68.22
0 to 150C
1
68.22
0 to 300C
5
68.22
Notes: *Not recommended for continuous use above 80O°E
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 12 I N C H STEM
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 4 I N C H STEM
Cat;
NO
THERMOMETERS - INDUSTRIAL, BI-METALLIC, 3 I N C H
DIAL, BACK-CONNECTED, 6 I N C H STEM
Each
68.22
83.22
68.22
68.22
68.22
58.22
68.22
68.22
65.22
68.22
68.22
68.22
Similar to 14-5432 except with 12-inch stem. Length of stem is 12
inches including threads. Stem should be immersed at least 2 inches
in liquid and 4 inches in gases.
Cat.
N~.
Temperature
Range,°
Subdivisions,
°
Each
14-5436-02
-40 to 160F
2
75,48
14-5436-03
25 to t25F
t
75.43
14-5436-04
0 to 220F
2
75.43
14-5436-06
50 to 300F
2
75.43
14-5436-07
50 to 400F
5
75.43
14-5436-00
50 to 500F
5
75.43
14-5436-09
150 to 750F
tO
75.43
14-5436-10
*200 to tOOOF
10
75.43
14-5436-12
0 to 50C
0,5
75.43
14-5486-15
-tO to 110C
1
75.43
14-5436-16
0 to 156C
1
75.43
14-5436-13
0 to 3000
5
75.43
Notes: *Not recommended tor continuous use above 800°E
1157
THERMOMETERS
00
Ul
DIAL-TYPE LABORATORY THERMOMETERS
14-5550
14-5555-01
14-5555-12
THERMOMETERS - LABORATORY, 1 3/4 I N C H O . D .
HEAD, 8 INCH SPIKE STEM, BI-METALLIC
These bi-metallic laboratory dial thermometers have a 1 3/4 inch dial
and an 8 inch pointed stem. Feature sturdy stainless steel
construction and super sensitive bi-metal silicone treated coil for fast
response. Anti-parallax dial has large, easy-to-read numbers with
raised graduations. Crystal is made of clear lexan plastic. Single scale
in either °F or °C. Can be easily recalibrated with hex screw. Accuracy
is 1% over the entire range. Stem should be immersed at least 2
inches in liquid and 4 inches in gases.
:Tempera~re :
14-6555-01
14-5555-82
14-5556-03
14-5555-04
14-5555-06
14-5555-06
14-5555-87
14-5555-08
14-6556-09
14-5555-10
14-5555-11
14-5555-12
14-5555-13
14-5555-14
14-5555-15
14-5555-16
14-5685-17
-100 to IOOF
25 to 125F
-40 to 160F
O to 18OF
O to 220F
O to 14OF
50 to 306F
50 to 4OOF
60 to 500F
20 to 240F
50 to 250F
-50 to IOOC
-10 to 110C
O to 1OOC
O to 150C
O to 250C
O to 60C
2
1
2
2
2
2
2
5
5
2
2
1
t
1
1
2
0.5
20.05
20.05
20.05
20.05
20.05
20.05
20.65
20.05
20,05
20.05
20,05
20.05
20.85
20.05
20.05
20.05
20.05
THERMOMETERS - POCKET DIAL, 1 I N C H O . D . HEAD,
BI-METALLIC
Bi-metallic, pocket thermometers with one inch dial and 5 inch pointed
stem feature stainless steel construction. Super sensitive bi-metal
silicone treated coil for fast response. Anti-parallax dial has large,
easy-to-read numbers with raised graduations. Crystal is made of
clear lexan plastic, Accurracy is 1% over the entire range. Supplied
with a plastic carrying case, which has attached pocket clip. Case can
be used as a handle.
Cat.
No!
14-5550-01
14-5650-02
14-5558-63
14-5550-04
14-5550-05
14-5550-06
14-5550-07
14-5550-08
14-5550-09
"
TemperalJre
Range,°
-40 to 16OF
25 to 125F
0 to 2OOF
50 to 500F
O to 156C
O to 250C
-40 to 70C
-10 to 110C
-40 to 120F
Subdivisions,
~
2
1
2
5
1
2
t
t
2
Each
17.22
17.22
17.22
17.22
17.22
17.22
17.22
17.22
17.22
DIGITAL THERMOMETERS
THERMOMETERS - LABORATORY, 2 I N C H O . D . HEAD,
8 I N C H SPIKE STEM, BI-METALLIC
Similar to 14-5555 except has a 2 inch diameter dial. Can be easily
calibrated with hex screw. Includes 8 inch spike stem. Accuracy is 1%
over the entire range. Stem should be immersed at least 2 inches in
liquid and 4 inches in gases.
: Temperaere
14-5580-01
14-5530-02
14-5530-03
14-5530-04
14-5530-05
14-5536-06
14-5530-07
14-5830-08
14-5530-09
14-5538-11
14-8830-12
14-5530-13
14-5530-14
14-8630-15
14-5530-16
1158
-100 to lOOF
25 to 125F
-40 to 16OF
0 to 180F
O to 220F
50 to 250F
50 to 30OF
50 to 40OF
50 to 500F
0 to 50C
-50 to IOOC
-10 to 110C
0 to tOOC
0 to 150C
O to 250C
. . . . . .
2
1
2
2
2
2
2
5
5
0.5
t
1
1
1
2
22-2967
DIGITAL POCKET THERMOMETER
28.56
28.56
26.56
26.56
28.56
28.56
28.56
28.86
28.66
28.56
28.56
28.56
28.66
28.56
Flat style digital pocket test thermometer originated as standard (not
an adaptation of other models). For use where conventional bimetal
pocket thermometers have been used. it will cover the range of-40
to 450°F with an accuracy of ±2°F (for -4 to 77°F) or ±4°F maximum
over entire range; has a resolution of O.I°E Large 0.25 inch high
oblong LC0 readout is easier to read than normal glass tbermometers. With instant update button and automatic shut-off. Features a
5 inch stainless steel stern for immersion. With red protective sheath
and pocket clip. Lifetime warranty.
Cat; :
Na~
Des~iption
|ach
28.56
22-2967-11
Digital Pocket Thermometer
29.50
THERMOMETERS
UI
22-3004
22-3002
THERMOMETERS - DIGITAL, POCKET, TRACEABLE
Lightweight thermometer with flat-profile design and built-in clip make
it ideal to carry in shirt pocket, Operating range is from -50 to 572°F
and 50 to 300°0 with resolution of 0.10 from -20 to 200°0 (1° otherwise) and accuracy of +-1.5°C.A hold button freezes a reading for later
use and another button switches from °F to °C. Large, bright LCD is
r/4 inch high and readings are updated every second.
Operates continuously for 11/2 years on a single replaceable
silver-oxide battery. Stern length is 3 r/e inches, stem diameter is 0.14
inch, overall length is 7 inches and weight is 1 ounce. Supplied with
protective probe guard case and certificate traceable to NI.STstandard.
22-3004-01
Pocket Thermometer
26.82
THERMOMETERS - DIGITAL, DIAL, TRACEABLE
Ideal for use in soil, cuvettes, food products and incubators. Choice
of °F or °C models with wide temperature ranges of -67 to 300°F or
-55 to 149°C. Resolution of 0.1 ° and accuracy -.1°. Large, bright
LCD display is 3/e inch high and readings are updated every 10
seconds. Stem length is 4 3/4 inches, stem diameter is 1/8 inch and
dial diameter is 1 1/2 inches in diameter, Operates for 1 V2 years on a
single silver-oxide battery. Supplied with protective case, battery, and
certificate traceable to NIST standard.
Ca~?
....
22-3062-01
22-3002-02
:
•
Digital Thermometeb -67 to 3OO°F
DigitalThermometer, 55 to 149°C
21.74
21.74
'\
22-3001
THERMOMETERS - L O N G - S T E M ,
DIGITAL, TRACEABLE
Long-stern thermometer fits into flasks, cuvettes, test tubes, and
beakers. Stainless steel probe is resistant to acids, bases, solvents
and most laboratory chemicals, Long stem allows user to make
measurements while stirring solutions. Also suitable for reading temperature in foods, gases, samples, and semi-solids. Temperature
range is -58 to 482°F and -50 to 250% with resolution of 0.1 ° from
-20 to 200 ° and 1° outside of this range. Accuracy is _+0.2% between
-20 and 100%. Reading are updated every second. Brilliant LCO
display is V4 inch high. Stainless steel stern is 8 inches long and 1/8
inch diameter. Overall length is 11 inches. Supplied with 1 year
battery and certificate traceable to NIST standard.
Cat
tfo.
22-3001-01
Long-Sterm Thermometer
28.15
21-2644
TEMPERATURE METER - PORTABLE, BATI'ERY
OPERATED, M O D E L T M P 5 0 , C O R N I N G ~
The Model TMP50 is a microprocessor based handheld meter that
accurately measures temperature in liquids, solids, and gases.
Features one button operation, LCD readout, K-type thermocouple
and housing, which is water and chemical resistant. Operating
temperature range from -40 to 550°C with resolution of 1°C and
accuracy _+2°C. Approximately 700 hours of operating battery life.
Overall dimensions are 7.3 x 1 .B x 0.9 inches. Supplied with general
purpose probe, battery and operating instructions. Optional probes
available for air, surface, and penetration applications.
cat.!:
:
Ce~.ni#g:
:
i
NO
::
21-2644-02
21-2644-85
21-2644-66
21-2644-67
21-2644-08
DesCrlption: '
475843
476452
476449
476450
476451
TemperatureMeter
GeneralPurpose Probe
Surface Probe
Air Probe
PenetrationProbe
;
Each
67.58
30.45
30.45
30.45
30.45
1159
THERMOMETERS
O
I-m
22-3006
THERMOMETERS - DIGITAL, DIAL, JUMBO DISPLAY,
TRACEABLE
Smooth, stainless steel probe is resistant to acids, bases, solvents,
and most laboratory chemicals. Provides continuous monitoring for
over a year. Includes on/off power switch and switch to change
between °F and °C. Operating temperature range is -58 to 302°F and
-50 to tSO°C with resolution of O.f ° from -20 to 200 ° and 1° outside
of this range. Accuracy is ±1°C between -20 and lOg°C. Extra large,
bright LCD display is 0.4 inch high and readings are updated every
second. Stem length is 5 r/4 inches, stem diameter is 1/8 inches, top
diameter is 2 1/8 inches, overall length is 6 r/2 inches and weight is 1
ounce. Supplied with replaceable silver-oxide battery and certificate
traceable to NIST standard.
Cat;i
:
No~ ~;
Description
Each
22-3006-01
Junrbo Display Dial Thermometer
30.24
22-3008
THERMOMETERS - DIGITAL, FULL-SCALE, TRACEABLE
Full-scale thermometer has large display, wide temperature range,
stainless steel probe and long cable. Operating temperature range is
-58 to 50O°F and -50 to 250°C with 0.1 ° resoJution from -20 to 200 °
and 1° otherwise. Accuracy is 1°C between -20 and tO0°C. Extralarge, bright LCD display is 0.4 inch high and readings are updated
every second. Thermometer has flip-open easel stand, spring clip
and magnetic back. Probe length is 5 ~rh6 inches, probe diameter is
~/8 inch, face diameter is 2 V8 inches, cable length is 10 feet and total
weight is 3 ounces. Silver-oxide battery operates continuously for
1 V2 years. Supplied complete with display, probe, cable, battery and
certificate traceable to NIST standard.
Cat,
No,
Description
Each
22-3008-01
Full Scale Thermometer
35.92
22-3010
22-3003
THERMOMETERS - BIG-DIGIT, DUAL DISPLAY,
MINIMUM/MAXIMUM
MEMORY, TRACEABLE
Big-Digit Thermometer offers easy to read temperatures from across
the lab. Dual displays permit reading ambient and probe temperatures simultaneously, Minimum/maximum memory reading may be
displayed or reset at the touch of a button. Temperature range of
ambient sensor, located inside of thermometer housing, is 23 to
122°F end -5 to 50°C. The external temperature probe with a 1g-foot
cable has an operating range of -58 to 158°F and -50 to 70°C.
Temperature resolution is O.t ° end accuracy is -+1°C. Minimum/maximum memory feature permits storing temperature records
overnight, on weekends or for longer time periods. Unit is equipped
with flip-open stand, a slot for wall mounting and a Velcro TM mounting
strip. Battery runs continuously for 1 year. Housing is high-impact,
chemical resistant ASS plastic with dimensions of 2 3/4 x 4 ~/4 x 3/4
inches and weight is 4 ounces. Supplied with AAA battery and
certificate traceable to NIST.
22-3010-01
1160
Desctiption
Big-Digit Thermometer
Each
30.77
THERMOMETERS - DIGITAL, SENTRY HIGH/LOW,
MEMORY, TRACEABLE
The Sentry High/Low Thermometer has a triple display, which
simultaneously shows high, low and current temperatures. Choice of
°F or °C models with temperature ranges of -58 to 158°F or-5O to 70°C
with resolution and accuracy of 1°. Sensor with 1g-foot cable may be
placed under water, in a refrigerator or in a freezer. Smag ~h6 inch
diameter cable allows refrigerator door to close. Simple one-button
operation resets the high/low memories. Operates continuously for
one year on supplied battery and includes low battery indicator. High
impact ASS plastic housing with flip stand, hanging hook and magnetic
back. Size is 2 5/8x 2 1/2x 3/4 inches and weight is 1.7 ounces. Supplied
with battery and certificate traceable to NIST standard.
Cat.
No.
Description
Each
22-3003-01
High/Low Thermometer, °F
31.42
22-3003-02
High/Low Thermometer, °C
31.42
22-3003-11
Replacement Probe
20.32
22-3003-12
AccessoryStainless Steel Probe
59.27
THERMOMETERS
22-3009
THERMOMETERS
TRACEABLE
- DIGITAL,
REFRIGERATOR/FREEZER,
Accurately monitors temperatures in refrigerators, freezers,water baths
and incubators with the enclosed "temperature buffered" sensor. Small
sealed bottle filled with glycol solution holds sensor and insulates against
rapid temperature changes when doors are opened. Triple display
simultaneously shows high, low and current temperatures. Minimum/
maximum display monitors readings overnight, on weekends or for
other periods of time. Alarm sounds when temperature rises above or
falls below set points. Alarm is programmable in 1° increments. Visual
and audible alarm signals continue for 12 hours even if temperature
returns to non-alarm range. Operating temperature range is -58 to
158°F and -50 to 700C with resolution of 1° and accuracy of +_10C.Tenfoot microcable permits refrigerator door to close. VelcroTM and magnetic strips are provided for mounting of both thermometer and bottle
sensor. High-impact, chemical resistant ABS housing is 2 3/4 x 4 V4 x
3/4 inches and weighs 4 ounces. Supplied with AA battery for one-year
continuous operation and certificate traceable to NIST standard.
C o t ;
:
H~
: :i
22-3005-01
OescrlptiOU
i :
:
Refrigerator/Freezer Thermometer
Each
36,91
22-3009
THERMOMETERS
TRACEABLE
- DIGITAL,
HIGH/LOW
22-3009-01
22-3009-11
22-3009-12
22-3009-13
22-3009-14
22o3009-16
22-3009-17
::
22-3007-01
DIGITAL
Each
High/Low Alarm Thermometer
43.99
COMPACT,
Description
:iech
Digital Thermometer
Replacement Probe
Accessory Micro Probe
AccessorySurface Probe
AccessoryAir/Gas Probe
Nylon Carrying Case
AC Adapter, 120V
399.00
51.32
86.61
119.64
85.10
14.70
30.77
22-2969-01
ALARM,
This thermometer is ideal for use in foods, soils, cuvettes, water baths,
and incubators. Both a high and low alarm may be programmed in 1°
increments. When temperature rises or falls below sot points, a 1 minute
audible alarm signals an out-of-range situation. Alarm automatically resets itself when temperature returns to within set points. Alarm mode
may be switched off when not required. Operating temperature range is
-58 to 500.8°F and -50 to 2600Cwith resolution of 0.1° and accuracy of
+_1°C.Switch from °F to °C or set high/low alarms. Digital display is 1 1/2
inches high and can be read from 10 feet. Stainless steel probe is 71/4
inches long, 1/8 inch diameter, with 3 foot cable and probe clip for handy
storage. Single battery runs continuously for 1 year. Supplied with probe,
AAA battery, and certificate traceable to NIST standard.
cat,:
PORTABLE,
Ideal for routine temperature measurements in soil, foods, cuvettes, gas
systems, water baths, and semi-solids. Operating temperature range is 40 to 3OO°Fand -40 to 150°C with resolution of 0.1" and accuracy of
_+0.2°C. Large, bright LCD display is V2 inch high and readings are
updated three times per second. Displays°F or °C at the push of a button.
Membrane keys offer a splash proof design. Universal stainless steel
probe is 61/4 inches long, probe diameter is ~/8 inch and cable is 5 feet.
Size is 3 1/2 x 5 1/2 x 1 ~/4 inches and weight is 8 ounces. Supplied with
probe, 9-volt battery and certificate traceable to NIST.
22-3007
THERMOMETERS
TRACEABLE
- DIGITAL,
22-2968-02
THERMOMETERS
Model TM-gA is a portable lightweight thermometer with a sealed
membrane touch pad. Will read in both °F and °C with an accuracy of
+_0.2°For °C or ±0.2% of reading, whichever is greater (32 to 120°F).
Temperature range is -40°F to +3gg°F with a resolution of 0.1°F or
°C, and an accuracy of ±B.2°F from -40 to +100°F; _+0.2%from 100
to 300°E Operational status is indicated on display. Constructed of
high impact resistant material making it perfect for field use. With 4
digit, 0.4 inch high backlighted LCD. Model TG-100A has the same
specifications, plus is rechargeable. Includes hard carrying case,
probe holder, rechargeable Nicad battery and recharger.
Cat;
NO~ :
:
:
Description
22-2966-01 TC-100A Digitat Rechargeable Thermometer
Portable, w/Case
22-2988-82
TM-99A Digital Thermometer
Portable, w/Case
Each
246.75
264.76
1161
THERMOMETERS
Ilam
22-2980
DIGITAL THERMOMETER - TYPE K THERMOCOUPLE,
BARNANT
22-2982
DIGITAL THERMOMETERS - TYPE J, K, OR T
THERMOCOUPLE, B A R N A N T
Portable, battery operated meter has a rugged housing and large ~/2 These easy-to-use meters are ideal for basic temperature monitoring
inch digital display with hold function to display °F or °C. Accepts all applications. Meters are available for J, K, or T type thermocouples.
type K thermocouple probes with ANSI miniconnectors. Field CAL Type K thermocouples are the most popular and offer a temperature
allows user to calibrate out error factor of individual probe.
range of -418 to 2501°F (-250 to 1372°C). Type J thermocouples
SPECIFICATIONS:
are rugged and reliable with a temperature range of -328 to t832°F
Temperature Range: -50 to 1999°F (-50 to 1300°C)
(-200 to IOOO"C). Type T thermocouples have the narrowest range
Resolution:
0.1 from -50 to 199.9;
but are ideal for low temperature applications with a range of -418 to
Auto ranging to 1 above 199.9
752°F (-250 to 400°C). The four button keypad is easy to operate
Accuracy:
±5% of reading or ±1°C
and includes on/off, C/F for °C or °F, hold and CAL. The CAL button is
whichever is greater
a "capture" mode for a single (ice) point field calibration offset. Field
Display:
31/2 Digit LCD, 1/2" High
calibration lockout feature prevents tampering and protects factory
Power:
One 9V Battery (Supplied)
settings. Housing is ABS/Polycarbonate impact resistant case with
Battery Life:
t20 Hours continous operation
sealed silicone rubber keypad and built-in tilt stand. Rated IP 54 for
Dimensions:
3"W x 6.5"H x I"D
Shipping Weight: 2.01bs.
splash and dust resistance.
One year manufacturer's warranty. Supplied with battery and SPECIFICATIONS:
Accuracy:
-+O.9°F (-+B.5°C) above g9°; _+2°F(zl°C)
instructions. Order Type K probe separately, see 22-2988,
Below 99° plus _+0.2% of reading
Resolution:
0.1 ° between -99.9 ° and 299.9°;
1° below 99.9°
Display:
3 3/4 Digit LCD, 1/2' High
22-2980-01
6OO-OOO0
Type K Thermometer
95.00
Power:
Two AA Batteries (Supplied)
Battery Life:
500 Hours minimum: Low Battery Indicator
Dimensions:
3.3'W x 6.2'H x f.2"D
Shinning Weight: O.71bs
Three year manufacturer's warranty. UL. cUL and CE certif .'c
Sunnlied with naperies instructions and certificate of conformance.
Order prone seoarateb, see 22-2988
Cat.
Bernant
No.
No.
gescriptla~
Each
22-2982-01 60D-1000
Type J Thermomezer
130.00
22-2982-02 600-1010
Type K Thermomezer
130 O0
22-2982-03 600-1020 Type T Thermometer
130.00
SEE OUR
CHROMATOGRAPHY
SELECTION
Chromatography Paper,
Columns, Ferrules, Injection
Port Liners, Septa, Sorbents,
Sprayers, TLC Plates,
Tanks, Vials
1162
SEE OUR SELECTION
OF SIEVE SHAKERS
ATM, CSC, W.S. Tyler
THERMOMETERS
........
,)
22-2986
22-2984
DIGITAL THERMOMETERS - DUAL INPUT J-T-E-K
THERMOCOUPLE, B A R N A N T
DIGITAL THERMOMETER A N D DATA LOGGER DUALOGR, THERMOCOUPLE, B A R N A N T
This meter accepts up to two thermocouple inputs and either J,K,T, or
E thermocouples. Manually stores up to 25 readings in
non-volatile memory. Features three 4-digit LCD displays and 12 button keypad for simplified set up and operation. Functions include on/
off, hold, calibration, °C/°F, J-T-E-K, maximum, minimum, differential
and store. Two point field calibration feature for offset and slope. User
can calibrate probe to known temperatures. Meter automatically stores
and adjusts for inherent probe error enabling unparalleled system
accuracy. Calibration lock out protects NIST traceable factory settings
and prevents tampering with field calibration values. Housing is ABS/
polycarbonate impact resistant case with sealed silicone rubber keypad
and built-in tilt stand. Rated IP 54 for splash and dust resistance.
The DuaLogR is a dual input portable thermometer and data logger,
which can manually store or automatically log up to 1000 sets of
readings in real time. Log interval is selectable from 1 second to 60
minutes. Data can be directly downloaded to the optional infrared
printer or to a computer with the optional RS232 interface adapter.
Meter accepts up to two thermocouple inputs, which can be selected
from the following types: J, K, T, E, R, S, N or B. Temperatures can be
displayed in °F, °C, °R, or °K scales. Resolution and input filtering are
selectable to improve readability during rapidly changing
temperatures. Features three 4-digit LCD displays and 12 button
keypad for easy operation. Capable of displaying minimum, maximum,
and differential readings simultaneously using one or two probes on
selectable, easy-to-read, muOi-data LCD. Two point field calibration
feature for offset and slope. User can calibrate the probe to one or two
known temperatures. Meter automatically stores and adjusts for
inherent probe error enabling unparalleled system accuracy. Calibration feature protects NIST traceable factory settings and prevents
tampering with field calibration values, Housing is ABS/polycarbonate
impact resistant case with sealed silicone rubber keypad and built-in tilt
stand. Rated IP54 for splash and dust resistance.
SPECIFICATIONS:
J: -328 to 1832% (-200 to IOOO°C)
T: -418 to 752°F (-250 to 4OO°C)
E: -418 to 1832°F (-250 to 1000°8)
K: -418 to 2501°F (-250 te 1372°C)
Accuracy:
±O.7°F (±O.4°C) above -238°F (-150°C); ±2°F
(±t°C) Below -238°F (-150°C);
plus ±0.1% of reading
Resolution:
0.1 ° at or below 999.9°; 1° greater 999.9°
Display:
Three 4-Digit LCD Displays,
0.4" and 0.2" High
Power:
Two AA Batteries (Supplied)
Battery Life:
500 Hours minimum; Low Battery Indicator
Dimensions:
3.3W" x 6.2"H x 1.2"D
Shipping Weight: O.71bs
Three year manufacturer's warranty. UL, cUL and CE certified. SupI~lied with batteries, instructions, and certificate of conformance. Order probe separately, see 22-2988.
Temperature
Ranges:
Cat
No~
22-2984-01
Bamant
No.
600-1040
:
Descrlption
Dual J-T-E-K
Thermometer
SEE OUR SELECTION
OF SYRINGE FILTERS
Osmonics, Pall, Whatman
:
EaCh
185.00
SPECIFICATIONS:
J: -328 to 1832°F (-200 to 1000°C)
K: -418 to 2501°F (-250 to 1372°C)
T: -418 to 752°F (-250 to 400°C)
E: -418 to 1832°F (-250 to IOOO°C)
R: 32 to 3241°F (0 to 1768°C)
S: -418 to 2372°F (0 to 1768°C)
N: -418 to 2372°F (-250 to 1300°C)
B: 392 to 3272°P (200 to 18go°c)
Accuracy:
Type 5, K, T, E and N: +0.7°F (±0.4°C)
Above -238°F (-150°C) ±2°F (-+1°C)
Below -238°F (-150°C);
plus ±0.1% of reading
Resolution:
0.1 ° less than or equal to 999.9°;
1° greater than 999.9°
Display:
Three 4-Digit LCD Displays,
6.4' and 0.2' High
Power
Two AA Batteries (Supplied)
Battery Life:
500 hours minimum, Low Battery indicator
Dimensions:
3.3'W x 6.2'H x 1.2'D2
Shipping Weigh1
0.71bs.
Three ~ear manufacturer's warranty. UL, cUL and CE certified. Supsued wlm oatrenes, instructions, and certificate of conformance. Oraer erode seoaretw, see 22-2988.
Temperature
Ranges:
Cat,
No.
22-2986-01
Barnnt
No.
Descriplien
600-1050
Thermometer/Data
Logger
Eech
240.00
1163
THERMOMETERS
.
.
.
.
.
. . . . . . . . . . . .
- - -
• ....
i t •
22-2988-01
i
=
.
.......
¸
22-2988-11
22-2988-41
THERMOCOUPLE PROBES - INTERGRAL HANDLE, BARNANT
Thermocouple Probes for use with Barnant Digital Thermometers and DualLogR thermometer/data logger. Can also be used with any thermocouple thermometer that accepts miniconnectors. Supplied with 5-foot coiled cables with PVC/PVCinsulation and miniconnectors. Cable are ANSI
color coded for easy identification: Type J cables are black, Type K are yellow, Type T are blue, and Type E are purple. Intergral probe handle is
5 1/e inches long glass-filled nylon. Choice of probes includes: general purpose, Teflon® coated general purpose, air/gas, surface and penetration.
General Purpose Probes
22-2988-01
601-1000
22-2988-02
601-0000
22-2988-03
601-2000
22-2988-04
601-3000
Teflon® Coated General Purpose Probes
22-2988.11
685-1757
22-2988-12
685-1657
22-2998-13
685-0057
22-2988-14
685-1257
Air/Gas Probes
22-2988-21
604-1000
22-2988-22
604-0000
22-2988-23
604-2000
22-2988-24
604-3000
Surface Probes
22-2988-31
602-1000
22-2988-32
602-0000
22-2988-33
602-2000
22-2988-34
602-3000
Penetration Probes
22-2988-41
603-1000
22-2988-42
603-0000
22-2988-43
603-2000
22-2988-44
603-3000
Maximum :
Temperature
Prabe
Length,in
Each
J
K
T
E
1400°F (760°C)
1652°F (900%)
550 °F (288°C)
1600°F (871°C)
4 15/16
4 15/16
4 15/16
4 15146
36.75
36.75
40.95
42.00
J
K
T
E
302°F
302°F
302°F
302 °F
(150%)
(150°C)
(150°C)
(150°C)
10
1O
10
10
57.75
57.75
57.75
59.85
J
K
T
E
572"F
572 °F
572°F
572°F
(300°C)
(30O°C)
(3go°c)
(3OO°C)
8 1/e
8 1/e
81/8
8 1/8
48,30
48.30
48.30
58.80
J
K
T
E
1200°F (649°6)
1200°F (649°C)
650 °F (343°C)
1200°F (649°C)
9 15/16
9 15/16
915/~e
915he
55.05
56.65
55.65
68.25
J
K
T
E
t4OO°F (760%)
1652°F (9OO°C)
550°F (288%)
1600% (871°C)
4
4
4
4
39.90
39.90
39.90
44.10
/
22-2986, 22-2987
21-2649
ACCESSORIES - FOR 22-2986, DUALOGR,
THERMOMETER AND DATA LOGGER, BARNANT
TEMPERATURE METER - PORTABLE, BATTERY
OPERATED, MODEL 309, CORNINGo
Accessories for DuaLogR thermometer and Data Logger. The
infrared printer is ideal for on-site documentation. Data is transferred
by infrared output, no cable to connect, just line up data transmission
LED located on top of instrument and position printer within 18 inches.
Print readings in real time from every three seconds to every 60 seconds or automatically print previously stored data. Printer supplied with
one roll of paper. Optional printer power adapter 110-240V, 50-6gHz
with 6-foot power cord. RS232 interface adapter connects data logger
to computer with 9-pin serial port for easy downloading of data. Does
not include software. Optional power adapter 115VAC for for DualLogR.
The Model 309 is a microprocessor based temperature measurement
system that uses a thermistor type of temperature input probe. This
portable, handheld unit accurately measures temperature in liquids, solids, and gases. Features include push button operation, LCD readout,
temperature display in °C or °E HI/LO recall, low battery indicator, and
auto off. Operating temperature range from -50 to 150°C with resolution
of 0.1°C and accuracy of ± 0.4°C. Approximately lOg hours of operating
battery life. Splash-proof housing with easy to use membrane keypad.
Overall dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless
steel general purpose probe, wrist strap, battery and operating instructions. Optional probes available for air and penetration applications.
Cal.
Coming
Ne~
:
No.
Descrlptian
Each
21-2649-02
475852
Temperature Meter
155.40
21-2649-05
476604
GeneralPurpose Probe
60.90
21-2649-07
476605
Air Probe
76.65
21-2649-08
476606
Penetration Probe
60,90
22-2987-01
22-2987-02
22-2987-08
22-2987-04
22-2987-00
1164
600-0080
600-0082
37455-71
600-0090
600-0070
Infrared Printer
235.08
PrinterAdapte5 100-240VAC 65.00
PrinterPapeE Pkg. of 6 Rolls 12.00
RS232 Inte~ace Adapter
95.00
DuaLogRAdapter, t15VAC
31.00
THERMOMETERS
..-=
Ut
21-2650
TEMPERATURE METER - PORTABLE, BAI"rERY
OPERATED, MODEL 3 1 0 , C O R N I N G ®
The Model 310 is a microprocessor based temperature measurement
system that usesa K- typethermocouple with detachableprobe handle.This
portable, handhetdmeter is ideal for a wide rangeof temperature measurement applications. Features include push button operation, LCD readout,
temperature display in °C or oF,HI/LOrecall, tow battery indicator, and auto
off. Operatingtemperature rangefrom -50 to 950°C with resolution of 0.1°C
(-50 to 150) and 1°C (>150). Temperatureaccuracy is _+0.5°C or _+0.5%
(-50 to 150) and ± 1.0°C or _+0•5% (>150). Approximately100 hours of
operating batterylife. Splash-proof housing with easyto use keypad. Overall
dimensions are 7.5 x 3.3 x 1.7 inches. Supplied with stainless steel general
purpose probe, wrist strap, battery and operating instructions. Optional
probes availablefor air, surface and penetrationapplications.
Cat; :
N0~
Carn!0it
" : N0
21-2650-02
21-2650-05
21-2650-06
21-2550-07
21-2650-08
21-2650-09
475853
476607
476610
476608
476609
470441
i
: : :
Descrlpt it~
:.!:
TemperatureMeter
General Purpose Probe
Surface Probe
Air Probe
PenetrationProbe
Probe Handle
i
:
Each
263.12
30.57
30.45
80.45
30.45
40.05
22-3035
HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M /
M A X I M U M M E M O R Y , TRACEABLE
Ideal for monitoring around-the-clock and for routine measurements
of relative humidity and temperature. Suitable for quality control
applications. Continuously and simultaneously displays relative
humidity and temperature in °E or °C with dual-recall memories.
Minimum and maximum memories may be displayed or cleared at
any time with the touch of a button. Environmental conditions can be
monitored overnight, on weekends, or for longer time periods.
Temperature range is 32° to t 22°F and 0° to 50°C with resolution and
accuracy of 1° . Humidity range is from 25 to 95% with resolution of
1%RH and accuracy of _+2% in mid-range to _+4% at the extreme
ends of range. East-response solid-state sensor displays changes in
less than 30 seconds. Large, easy-to-view 5/8 inch high digits are
updated once every second• Meets federal requirements for CLIA
specification 493.1207 for monitoring temperature and humidity in
labs. Case is shock and chemical-resistant ABS plastic. Size is 2 5/e x
3 7/8x 3/e inches and weight is 2 1/2ounces. Supplied with wall mount,
bench stand, solid-state sensors, switch to read °F/°C, two AAA
batteries and certificate traceable to NIST. Choice of three models
available. Catalog number 22-3035-01 offers digital humidity/temperature with dual minimum/maximum memories. Model 22-303502 offers digital humidity with minimum/maximum memory but
without temperature. Catalog number 22-3035-03 offers digital
humidity/temperature but without memories•
Cat;
NOi ~ . . . . .
PEN - DIGITAL,
Pocket pen with clip is easyto carry and is idealfor measuring humidify and
temperature levels. Pen continuously and simultaneously displays both RH
and °F or °C with dual-racall memories. Memory displays highest ano
lowest humidity/temperatura readings observed overnight or during any
time period. Easy-to-read LCD display is 1 1/2 inches high and is upoatea
once every second. Pocket pen has fast-response solid-state sensors.
which respondto changes in less than 30 seconds. Temperature range ~s
32° to 122°E and 0° to 59% with resolution of 0.1° and accuracy of +_1°C.
Relative humidity range is 2 to 98% with resolution of 1% and accuracy of
_+2%at mid-range to 4% at ends of range. Supplied with two s [ver-oxloe
batteriesfor 6 month of continuous operation. Caseis high-impact, chemical resistantABS plasticwith dimensions of 5 Vex 1 x 7/8inches and weight
of 1 1/2 ounces. Supplied with batteries and certificate traceable to NIST
Cat.
NO.
" .
22-3037-01
"
Descdptlon
:
22-3036-01 Hygrometer/Thermometer, Min/Max Memory
22-3035-02
HygrometerOnly with Min/Max Memory
22-3035-03 Hygrometer/Thermometer without Memory
22-3037
HYGROMETER/THERMOMETER
M E M O R Y , TRACEABLE
i
Des¢rlp0ee
Each
Hygrometer/Thermometer Pen
48.23
]Each
60.59
51.67
57.77
SEE OUR SELECTION
OF FILTER APPARATUS
Nalge Nunc, Osmonics,
Pall, Whatman
1165
THERMOMETERS
22-3036
HYGROMETER/THERMOMETER - DIGITAL, M I N I M U M /
M A X I M U M MEMORY, TRACEABLE
Continuously and simultaneously displays relative humidity and
temperature in °F or °C with dual-recall memories. Minimum and maximum
memories may be displayedor clearedat any time with the touch of a button.
Conditions can be monitored overnight, on weekend or for longer time
periods. Contains ambient relativehumidity and temperaturesensors within
case and externaltemperature sensor with lO-foot cable. Externaltemperature probe rangeis-58 to 158°Fand -50 to 70°C.Ambient sensorrangeis 23
to 122°Fand -5 to 50°C. Temperatureresolution is t ° and accuracyis _+1°C.
Humidity rangeis 25 to 95% with resolution of 1% BA and accuracyof ±2%
in the mid-range to ~ % outside of mid-range. Fast response solid-state
sensors show display changes in lessthan 30 seconds. Large,easy-to-view
1 ~/8 inch high digits are updatedonce even/second. Meets federal requirements for CLIA specification 493.1207 for monitoring temperature and
humidity. Caseis shockand chemical-resistant. Sizeis 3 7/8x 4 r/4 x3/4inches
and weight is 5.4 ounces. Supplied with flip-open stand, wall mount, AAA
batteryand certificatetraceableto NIST
22-3036-01
Digital Hygrometer/Thermometer
|.oh
56.50
22-3039
HYGROMETER/THERMOMETER - DIGITAL, TRACEABLE
ideal for constantly monitoring labs, fume hoods, plant areas and
storage facilities. Provides humidity and temperature readings
instantly. Humidity range is 25 to 95%BH with resolution of 1% and
accuracy of _+2%RH at mid-range to _+4% at ends of range.
Temperature range is 32° to 122°F and 0° to 50°C with resolution of
0.1 ° and accuracy of ±1 °C. Large, easy-to-read LCD has V2 inch high
digits. Modern design is housed in a rugged ABS plastic case with
dimensions of 3 ~/2 x 5 x 7/8 inches and weighs 6 ounces. Single AA
battery provides I 1/2 years of continuous operation. Supplied
complete with screw for wall mounting, plastic stand for bench use,
battery and certificate traceable to NIST.
Cal.
No,
Description
Each
22-3039-01
Digital Hygrometer/Thermometer
48.03
RECORDING THERMOMETERS
WEATHER H A W K RECORDING THERMOMETER
22-3038
HYGROMETER/THERMOMETER - DIGITAL, MEMORY,
TRACEABLE
Unit constantlymonitorstemperature and humiditywith memorycapabilityto
recall high and low readings. The instrument is always on, as there is no off
switch, and makes continuous readings.Equippedwith an ambient humidity/
temperature sensor inside of the housing and an externaltsmperatureprobe
with a 10 foot cable. Displaysimultaneouslyshows probetemperature,ambient temperature and ambient humidity Minimum anD maximum memory
readingsmay be recalledor clearedwith the rouce of a button. Humioayrange
is 25 to 95% RH with resolution of 1% and accuracyof _+2%at mid-rangeto
-+4°/°at ends of range, ambient temperature range is 32" to 122°Fand O" to
50°C. ExtemaJtemperature sensor range is -58° to 158°Fand -50° to 70°C
Temperature resolution is 0.1° and accurac~ is _+1"0.Bright LCD Digits are
V2 inch high. Case is high-impact, Chemical resls~am ABS nlastic with
dimensions of 3 V2 x 5 x 7/8inches and weight is 6 ounces.Two AA eanenes
provide one year of continuous operation. Suoolled comolete with ulastlc
stand, internal humidity/temperature sensor, and external zemeerature
sensor with 10 foot cable, AA batteriesand certificatetraceableto N S]~
22-0038-01
1166
Digital Hygrometer/Thermomezer
56.43
Provides a continuous record of temperature variations over a 7 day
period. Accuracy is ±I°E It can be used outdoors or in the laboratory
area, for example, in environmental cabinets. Dimensions are 13 x 7
x 7 inches high. The electrically driven drum revolves one complete
turn in seven days. The chart, in 2° divisions, ranges from -40 ° to
120°F and has colored bands which clearly indicate the significant
temperature zones for convenient reading. Complete with 40 foot
capillary tubing, 3-wire cord and plug, 52 charts, ink and
instructions. For operation on 110 volts, 60 Hz, AC.
(:at.
No.
Description
Each
22-2995-01
Weather Hawk Thermometer
600.00
SEE OUR SELECTION
OF FUME HOODS
Captair, Kewaunee, Labconco
THERMOMETERS
",4
22-3080
THERMOMETERS - R E C O R D I N G , P E R M A N E N T D R Y
STYLUS, PTC
22-3050
THERMOMETERS
BACHARACH
- R E C O R D I N G , TEMPSCRIBE,
These recording thermometers have a wide range of laboratory
applications such as continuous recording of temperatures in heated
or refrigerated incubators, controlled temperature rooms,
fermentation cabinets or similar compartments. They can also be
used for meteorological recordings if suitably protected from rain,
snow and direct sunlight. Each instrument consists of a hi-metallic
coil which has a thermal responsiveness of 0.5°F, recording pen and
chart which is turned by a sturdy spring-wound clock, all mounted in
a strong plastic case which can be flush mounted, suspended or set
on a level surface. Temperature chart is 4 1/2 inches in diameter. Each
unit is suppiied complete with two marker pens and 100 charts.
Ca
No.
:
Temperature
range
onecharf Temp.
~rn dv.
Time
dv.
:
:Each
22-3050-01
22-3050-02
22-3050-05
22-3050-06
22-3050-09
22-3050-11
-30 to 120°F 7 days 5°F
3 hr,
-30 to 120°F 24 hr.
5°F 15 min
40 to 10O°F 7 days 2°F
3 hn
40 to t00°F
24 hr
2°F 15 min
-tO to 50°F
7 days 2%
3 hr
30 to 50°0
7 days 2°C
3 hr.
RECORDER CHARTS-FOR 22-3050
Catalog suffix numbers correspond with those of the
Recorders, e.g., 22-3051-01 is for 22-3050-01.
Cot
:N~!!i ~' i~i:~:~il ~
~i~
: :i;
!
~
390.02
390.02
390.02
390.02
390,02
390.02
22-3050
Pkg
Qiy~Price!
~,:
22-3051-01
22-3051-02
22-3051-55
22-3051-06
22-3051-09
22-3051-11
100
100
105
100
100
100
-27.00
-27.00
- 27.00
- 27.00
- 27.00
-27.00
M A R K E R PENS - F O R TEMPSCRIBE R E C O R D I N G
THERMOMETERS
Two marker pens in two-compartment Mylar packet for use with 223050 Recording Thermometers. For use at -30 to +150°F; 0-100%
humidity. Provide 6 months to one year continuous use.
Cat;
::
:
N~
COoi":
22-3064-02
Red
Pko
: : Qty--Price i
2-
22.83
Portable unit records temperatures permanently over periods of up
to 24 hours or up to 7 days, Accuracy is _+2%of full scale range. Can
withstand rugged environment and rough handling. Ideal for use in
refrigerators, coldrooms, dairies, drying sheds, greenhouses as well
as in schools, hospitals, and offices. For wet environments or
extremely high humidity, the unit can be placed in a heavy
polyethylene bag or sealed container, Clock movement is spring
wound. A permanent, sharp stainless steel stylus presses against a
plastic coated 3 5/8 inch circular chart leaving a distinct black line
against the white paper and blue temperature and time graduations.
NIST certification available upon request. 100 charts are provided.
Cat~ -:
HO~!
=
Range°F/°C
Tlmerahge
=
22-3080-01
22-3080-02
22-3080-03
22-3080-04
22-3080-05
22-3080-06
22-3080-07
22-3050-08
22-3580-09
22-3080-10
22-3080-11
22-3080-12
22-3080-13
22-3080-14
-40 to 160°F
24 hrs.
40 to 160°F
7 days
0 to 10O°F
24 hrs.
0 to 1OO°F
7 days
20 to 220°F
24 hrs,
20 to 220°F
7 days
-5 to 50°C
7 days
-5 to 105%
24 hrs.
-5 to 105°C
7 days
-5 to 5O°C
24 hrs.
20 to t20°F
24 hrs.
20 to 120°F
7 days
-30 to 7O°F
24 hrs.
-30 to 70°F
7 days,
22-3080-15
-40 to 70%
24 hrs.
22-3080-16
-40 to 70°C
7 days
RECORDER CHARTS-FOR 22-3080
Catalog suffix numbers correspond with those of
Recorders, e.g., 22-3083-01 is for 22-3080-01.
Car.;
NQ~
:
~
22-3083-01
22-3083-82
22-3083-03
22-3083-04
22-8883-05
22-3083-06
22-3083-07
22-3883-08
22-3083-09
22-3083-10
22-3083-11
22-3083-12
22-3083-13
22-3083-14
22-3083-15
22-3083-16
MOUNTING
Each
504.00
504.00
504.00
504.00
504.00
504,00
504.00
504.00
504.00
504.00
504.00
504.00
504.05
504.00
504.00
504,00
22-3080
9kg
Qty-Pdce
100
100
100
100
100
180
180
100
100
100
100
100
100
100
100
100
-13.50
-13.50
-13.50
- 13.50
-13.50
- 13.55
-13.50
- 13.50
-13.50
- 13.50
- 13.50
- 13.50
-18.50
- 13.50
-13.50
- 13.50
BRACKET - STAINLESS STEEL
Cet, i .
22-3081-01
Description
" Each
Mounting Bracket
32.81
1167
THERMOMETERS
-,%
cO
22-3365
RELAY CONTROL - SOLID STATE, MECHANICAL,
P R I N C O T688
22-3230
THERMOREGULATOR - FULL RANGE TYPE,
M A G N A - S E T ~, P R I N C O
Fully adjustable, rapid setting thermoregulator with an accuracy to
0.002°0. Exclusive Pdnco Magna-Set principle brings accuracy and
sensitivity formerly unavailable in adjustable temperature controls.
Unique design features include a variable electrode with a magnetically controlled micrometer adjustment which permits changes of
0.005°C in operating temperature and improved mercury trap (or
reservoir) used in making the preliminary, rough adjustment.
Controls a well agitated constant temperature bath of good design to
within 0.01°C Under ideal conditions a variation as little as 0.002°C
has been maintained. Overall length is 335 mm including a two-piece
detachable connector and cord. Diameter of ooey iS 14 ram, A suoer
sensitive relay (22-3362-11 Js recommenaea: maximum capacity is
3 milliamperes at 110 volts 60 Hz. AC.
-~"
22-3230-11
DescriFtion
Thermoregulazor
Each
420.00
For use with laboratory thermoregulators and thermostats. Unit combines solid state and mechanical components to obtain the advantages of both. There are two input binding posts, two AC receptacles
and a load indicating pilot light. A one second time delay prevents
chattering. This relay controls a resistive load up to 1000 watts. It
operates on 115 volts, AC and provides an activating current of 100
microamperes at 7 volts DC. Complete with a heavy-duty line cord
and plug. Case measures 4 x 4 x 2 inches.
Cat.
No.
Description
22-3365-01
Relay Control
SEE OUR
GLOVE SELECTION
Disposable Gloves,
Reusable Gloves,
Chemical Resistant Gloves,
Temperature Resistant Gloves
22-3362
RELAY CONTROL - SOLID STATE, PRINCO T681SS
A heavy duty solid state controller for use with laoorazory mermoregulators, especially the 22-3230-1t. Controls cads frorr 25 to 1500
watts. "Percent Power" ala regulates power from O zo 100%.
Provides signal current of only 6 microamoeres to tl~e thermoregulator. With twin pilot lights, controlled Ioaa aria convemence outlets
and heavy duty 3-prong plug. Case measures 7 x 6 x 4 inches Ii~gh.
For operation on 115 volts. AC
22-3362-11
1168
Relay Control
Each
630.00
SEE OUR
BALANCE SELECTION
A & D Weighing, Acculab,
Ohaus, Sartorius,
Thermo Cahn, Troemner
Each
288.75
THERMOMETERS
SPECIAL-USE THERMOMETERS
...a
...a
14-5000
THERMOMETERS
- "EXACT-TEMPE"
ERTCO
Consists of an NIST traceable, Teflon®-coated thermometer in an unbreakable plastic bottle filled with propylene glycol, ethylene glycol or
vermiculite. Each thermometer has an individual serial number and has been listed against a standard calibrated at the National Institute of
Standards and Technology (NIST). A certificate of accuracy is supplied with each thermometer, Velcro is affixed to each bottle permitting the
thermometer to be attached to the wall or door of the instrument, reducing space and breakage problems. All thermometers are total
immersion.
cat
Range,
Length,
Div.,
Type
~
Liquid
Each
No. :
nslremeet
: C
ran.
C
14-5000-01
14-6000-02
14-5000-03
14-5000-04
14-5000-05
14-5000-08
14-6000-07
14-6000-08
14-5000-09
14-500G-10
14-5000-11
14-6000-12
Ultra-low Freezer
Freezer
Blood Bank
Refrigerator
Incubator
Oven
Oven
Freezer
Refrigerator
Incubator
Oven
Oven
-90 to 20
-30 to 0
-5 to 20
-5 to 15
-18 to 50
20 to 130
35 to 200
-30 to O
-5 to t5
18 to 50
20 to 130
35 to 200'
145
125
125
125
135
135
145
1 O0
125
1 go
135
145
1.0
0.5
0.5
0.5
0.5
1.0
1.0
1 .O
0.5
1 .O
1.0
1.0
Spirit
Spirit
Spirit
Spirit
Spirit
Spirit
Spirit
Mercury
Mercury
Mercury
Mercury
Mercury
PP Glycol
PP Glycol
Eth. Glycol
Eth. Glycol
Eth. Glycol
Vermiculite
Vermiculite
PP Glycol
PP Glycol
Eth. Glycol
Vermiculite
Vermiculite
58.48
46.41
70.14
46.41
46.41
48.41
78.01
46.41
46.41
46.41
46.41
78.01
SEE OUR SELECTION OF TUBING
Fluoropolymer, Latex, Norprene, Polyethylene, Polyvinyl Chloride,
Polyurethane, Pure Gum Rubber, Silicone, Teflon, Tygon
SEE OUR SELECTION OF PIPETTORS
BD Medical, BrandTech, Eppendorf, Finnpipette, Jencons,
LabBest, Oxford, Popper, Volac
1169
THERMOMETERS
~(~
14-5930
THERt~4OMETERS - PRECISION., FOR SPECIAL APPLICATIONS, ERTCO
All thermometers are serialized for the purpose of traceability and all are accurate to within NIST (NBS) tolerances.
rv~
IC
1.0
1.0
1.0
10
0.5
0.5
1.0
1.0
0.1
0.1
0.5
05
1.0
1.0
1.0
1O
1.0
1.0
0.5
0.5
1.0
10
1O
1.0
1O
1.0
1.0
10
t0
1O
1.0
1.0
2.0
20
tO
10
05
SFeda
:fea!utes*
1, 2
1, 2
Applkatlons
incubator, Water Bath
Incubator, Water Beth
Incubator, Water Bath
Incubator, Water Bath
Incubator, Water 6aths
Incubator, Water Bath
Incubator, Water Bath
Incubator, Water Beth
Coliform Incubator
Coliform Incubator
Block Heater, Water Bath
Block Heater, Water Bath
Block Heater, Water Bath
Block Heater, Water Beth
Short Immersion Bath
Short Immersion Bath
Blood Bank, Refrigerator
Blood Bank, Refrigerator
Incubator, Water Bath
Incubator, Water Beth
Autoclave, Max. Reg
Autoclave, Max. Reg
Ovens, Oil Baths
Ovens, Oil Baths
Ovens
Ovens
Ovens
Ovens, Oil Baths
Ovens, Oil Baths
Ovens, Oil Baths
Ovens, Oil Bathe
Ovens
Vacuum Ovens
Vecuum Ovens
Vecuam Ovens
Vacuum Ovens
Enzymology
14-5930-03
20 to 100
305
76
14-5930-13
20 to 100
305
76
14-5969-64
0 to 60
250
1 O0
14-5030-14
0 to 80
250
100
14-5930-01
0 to 50
305
150
i
14-5930-11
0 to 50
305
150
1
14-5930-02
O to 70
330
150
1
14-5930-12
6 to 70
330
150
1
14-5930-05
34.5 to 46
237
76
2
14-5930-15
34.5 to 46
237
76
2
14-5929-01
25 to 57
175
35
2
14-5929-11
25 to 57
175
35
2
14-5929-02
0 to 100
225
35
14-5929-12
0 to 100
225
35
14-5928-01
O to 50
1 O0
12
14-5928-11
0 to 50
1 O0
12
14-5927-01
-5 to 20
t 52
Total
2
14-5927-11
-5 to 20
152
Total
2
14-5930-06
25-37-56
240
76
2
14-5930-16
25-37-56
240
76
2
14-5930-07
80 to 135
200
Total
14-5930-17
80 to 135
200
Total
14-5925-01
O to 300
405
125
i
14-5925-02
O to 300
455
150
1
14-5925-03
0 to 300
610
305
1
14-5925-04
0 to 200
610
305
1
14-5925-14
0 to 200
610
305
1
14-6925-05
0 to 200
280
76
1
14-5925-15
0 to 200
280
76
1
14-5925-06
0 to 200
405
125
1
14-5925-16
0 to 200
405
125
1
14-5925-07
0 to 350
455
150
1
14-5926-01
24 to 130
135
Total
14-5926-11
24 to 130
135
Total
14-5926-02
35 to 200
180
Total
14-6926-12
35 to 209
180
Total
14-5032-01
24 to 38
300
95
*Special Features:
1. Immersion enlargement on thermometer stem 2. Arrows on scale indicating critical temperature
SEE OUR SELECTION OF BRUSHES
Assay, Beaker, Bottle, Buret, Camel Hair, Carboy,
Centrifuge Tube, Cylinder, Flask, Graduate, [mhoff Cone,
Pipet, Static Master, Test Tube
1170
Teflo.®
coaled
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yea
No
Yes
No
Yes
No
No
No
No
Yes
No
Yes
No
Yes
No
No
Yes
No
Yes
No
Each
44.73
52.60
32.65
40.53
31.81
39.58
39.06
46.83
68.04
75.81
43.36
51.13
42.94
50.71
42.94
50.71
25.51
33.28
33.07
40.95
52.50
60.99
38.95
46.30
62.05
62,05
69.82
38.32
38.32
42.90
49,77
62.65
35.91
43.68
36.75
44,52
74.76
THERMOMETERS
THERMOMETERS - ASPHALT TESTING, THERMOMETER
ONLY
C=ti
NO,
14-5399-01
14-5399-02
Range,°F
:
|=ch
50-450
50-600
50,77
26.26
d
THERMOMETERS - CLINICAL, ASEPTO ®, B'D T M
Accurate and dependable fever thermometer with easy-to-read blue
scale. Reads in Fahrenheit. Supplied in white plastic case with Lok-ln
feature.
Cat;
:
Pkg
No, ~
9-DTMNo.
Typebulb
Qly- price
14-5885
THERMOMETERS - AIR I M M E R S I O N , CLEAN R O O M ,
PTC ®
These instruments are engineered to accurately measure ambient air
temperature within +_2% of full scale range. Ideally suited for
temperature-controlled clean rooms, cold rooms, laboratories and
large areas or volumes used in environmental testing, Three
temperature ranges are available: -20°F to +160°E O°F to 250°F and
O°F to 50O°E Dimensions: 2 inch diameter x height, 1 inch. An
ancillary hand is available for this instrument. It is held by a magnetic
clutch and will retain a maximum or minimum reading. One year
warranty. NIST certification available upon request.
Cal~
No,
14-5885-01
14-5885-02
14-5885-03
lu~ II
Range,~:
°F . . . . . . .
-20 to 160%
0 to 250°F
0 to 500°F
Subdlv.
2°
2°
5°
With Ancillary Hand
14-5885-04
-20 te 160°F
14-5885-05
0 to 250°F
14-5885-06
0 to 500°F
2°
2°
5°
.....
Each
68.25
68.25
68.25
14-4795-01
14-4795-02
524015
524025
Oral
Rectal
66-
29.42
29.42
14-5935
THERMOMETERS - D E W P O I N T
Totalimmersion thermometers with an overalllength of 255mm.
Cat.!
Noi
14-5935-91
14-5935-02
ana
Re,
-30 to 110
-90 to 40
Sub~
: dlv;
Each
1°
1°
30.66
51.34
87.93
87.93
87.93
THERMOMETERS - ASPHALT TESTING
Supplied with penetration nickel plated brass armor case. Overall
length 11 inches; 5 ° divisions.
Cat;
Noi
14-5398-01
14-5398-02
:
Thermometer Only
14-5399-01
14-5399-02
Renge~°F
50 - 450
50 - 600
Each
56.38
56.38
50 - 450
50 - 600
50.77
26.26
THERMOMETERS - ASPHALT TESTING, POCKET TYPE
100 - 450°F with epoxy coated bulb for penetration protection; 5
divisions. Complete with aluminum protective case.
No.
14-5406-01
14-5400-02
Range~ F
~~
Thermometer w/Case
Refil~ Only
Each
44.52
35.70
14-5780
THERMOMETER - DOUBLE SCALE, I N D O O R , COMFORT
METER TM, TAYLOR
With permacolor tube and magnifying lens. Wood grained frame
finish. Bold white numbers and graduations on a brown background.
Ranges are -60 to 130°F and -50 to 55°C. Overall dimensions are
7 5/8x 2 1/4 inches.
Ce|. :
No; :
14-5780-01
~
Description
Double Scale Thermometer
~
Each
11.95
1171
THERMOMETERS
C'q
r~
14-5850
THERMOMETERS - M A X I M U M REGISTERING,
MERCURIAL, W I T H PROTECTIVE CASE
14-5840
THERMOMETER - M A X I M U M
REGISTERING, TAYLOR
AND MINIMUM,
SELF
Complete with setting magnet and improved tube fastening. With a
range from 40 to 130°F in two degree divisions. High temperature is
registered at top of one side and low at top of other side. Mercury
filled. Dimensions are 10 V2x 2 3/sx 1 ~/4 inches.
o~
:
14-5840-01
:
Thermometer
:
Each
23.49
For general testing in applications where it is impractical to make an
immediate reading. The mercury column will not recede until shaken
down or reset similar to fever thermometers. Overall length is 61/2
inches. Available in fully enclosed pocket case or in open-faced armor
case. Cases are anodized aluminum and provided with pocket clip.
Cat.
Scale
SubNoi
ra~e
dlv.
Each
Complete
14-6850-11
14-6950-12
14-5650-13
14-5650-15
cat.
N0.
O to 220°F
50 to 3OO°F
50 to 40O°F
-20 to 150°C
2°
2°
2°
1°
renge
Replacement Thermometer-for 14-5850
14-5855-11
O to 220°F
14-5855-12
50 to 300°F
14-5655-13
50 to 400°C
14-5359-15
-20 to 150°C
45.36
45.36
45.36
45.36
Each
37.60
37.90
37.90
37.90
14-5842
THERMOMETER - M A X I M U M
REGISTERING, DUAL SCALE
AND MINIMUM,
SELF
Ranges are -40 to 5O°C in 1° divisions; -40 to 120°F in 2° divisions.
Mercury filled. Reset with the press of a button.
14-4975
14-5842-01
Thermometer
MICROCHEMISTRY KITS
SEE
Corning, Wheaton
12-9960 TO 12-9965
]172
75.00
THERMOMETERS - MERCURIAL, FLOATING DAIRY,
FAHRENHEIT
Has a transparent coating for protection against shattering on sides
of vat. The coating does not interfere with reading, and in case of
breakage prevents contamination by mercury and glass fragments;
is not affected by action of hot milk and will have no effect on the taste
or quality of the milk• Diameter is 15 mm; length is 270 mm.
Cat,
Range,
SubNe.
°F
dlv.,°
Eeck
14-4975-Ol
20 to 160
2
32.76
14-4975-02
20 to 220
2
34.02
THERMOMETERS
Q
14-5880
THERMOMETERS - SURFACE TEMPERATURE, DUAL
MAGNET, GLASS COVER, PTC ®
14-5900
THERMOMETERS - SPOT CHECK, 1 a/4 INCH DIAL, PTC~
Employs a bimetallic coil sensor which has direct contact with the
surface to be measured. In response to temperature, the sensor
expands or contracts causing the 1 3/4 inch dial itself to rotate. This
thermometer reads temperatures of all flat surfaces such as dies, hot
plates, heavy sheet metal, etc. It also reads ambient temperatures in
enclosed spaces, as well as in noncorrosive liquids and gases, up to
1000°E Accuracy is _+2% of full scale. NIST certification available
upon request.
Cat;
No.
:
Range,
F/°C " i
,
14-5900-01
14-5900-02
14-5900-03
14-5g00-04
14-5900-05
14-5900-06
14-5900-07
O to 270°F
50 to 320°F
50 to 5OO°F
50 to 1000%
10 to 160°C
10 to 260%
O to 525°C
S..b, :
dlv.
Each
2°
2°
5°
10 °
1°
2°
5°
36.75
36.75
36.75
21.00
36.75
36.75
21.00
Designedto be used on hodzontalor ferrous non-horizontalsurfaces. Dimetallic sensor is locatedin a draft shieldand is in virtual thermal contactwith
surface to be measuredgivinga relativelyquickresponsetime. Glasscovered
dual magnetsurface thermometeroperates across a total rangefrom -100
to +750°Fand-70 to +400°Cwith an accuracyof ±2%. Diameteris 2 inches.
Two Alnico magnetshold it securely in placeon horizontalor non-horizontal
steel or ferrous metalsurfaces. NISTcertificationavailableupon request.
CaI~
Na~
:
14-5880-01
14-5880-02
14-5880-03
14-5880-04
14-5880-05
14-5880-06
14-5880-07
14-5080-08
14-5880-09
14-5880-10
Range,
"F/°C
Subdlv,
Each
-100 to 160°F
0 to 150°F
O to 250°F
0 to 5OO°F
50 to 750°F
-70 to 70°C
-15 to 65%
-20 to 120°C
-20 to 250°C
10 to 400%
2°
1°
2°
5°
10 °
2°
1°
1°
2°
5°
52.44
52.44
52.44
52.44
29.95
52.44
52.44
52.44
52.44
29.95
THERMOMETERS - SPOT CHECK, I 3/4 INCH DIAL,
N O N - H O R I Z O N T A L SURFACES, PTC ®
Similar to 14-5900 but includes magnet and leaf spring for use on
non-horizontal ferrous surfaces or for permanent mounting. NIST
certification available upon request.
Car
: ~
" Range
NO,
: "Fp~ '
14-5901-91
0 to 270%
14-5901-02
50 to 320°F
14-5901-03
50 to 5OO°F
14-5901-04
50 to IOOO°F
14-5901-05
10 to t60°C
14-5901-06
10 to 260°C
14-5901-07
0 to 525°C
i
THERMOMETERS - SPOT CHECK, i
M A X - M I N , PTC ®
Sub, ; '
diW
2°
2°
5°
10 °
1°
2°
5°
3/4
:
Each
45.51
45.51
45.51
45.51
45.51
45.51
45.51
I N C H DIAL,
Similar to 14-5901 but with Max-MJn pointers to indicate lowest and
highest temperatures reached during the thermometer's exposure.
NIST certification available upon request.
Cat.
Ne~
14-5902-01
14-5902-02
14-5902-03
14-5902-04
14-5902-06
14-5902-07
i
Range,
:
"EpC
O to 270°F
50 to 320°F
50 to 500°F
50 to IOOO°F
10 to 260°C
0 to 525°C
gub.~ :
dl~;i
2°
2°
5°
10 °
2°
5°
!aCK
48.98
48.98
48.98
40.08
48.98
48.98
14-5881
THERMOMETERS - SURFACE TEMPERATURE, PTC ®
Thermometers are fully enclosed to protect bimetal from dirt and dust.
Diameteris 2 inches. Requires either a small magnet clamp to hold it
securely in place on non-horizontal steel or other ferrous metal surfaces, or heavy silicone grease which can be used to stick the thermometer to any flat surface. NIST certification available upon request.
Cob
No;
i
Range :
"F/"C
~
Subi ~
~ dlv~
:
EaCh
14-5881-01
-50 to 250~F
2°
47.00
14-5881-02
-50 to 110°C
2°
47.00
14-5081-03
0 te 300°F
2°
47.00
14-5881-04
-10 to 150°C
2°
47.00
14-5801-05
70 to 370°F
2=
47.00
14-5881-06
20 to 180%
2°
47.00
MAGNET AND LEAF SPRING, FOR 14-5881 THERMOMETER
Clampholdsthermometersecurely in placeon steelor otherferrous metals.
Cat~
Ne~
Description :
.
~ Each
14-5882-01
Magnetic Thermometer Clamp
5.00
THERMOMETER ADHESIVE-SILICONE, FOR 14-5881 THERMOMETER
Silicone grease holds thermometer securely on any flat surface.
Caf~
No~
14-5983-01
Description i
i
Thermometer Adhesive
Each
7.08
1173
THERMOMETERS
14-5903
THERMOMETERS - SURFACE, MINIATURE SPOT
CHECK, PTC ®
Designed to measure surface temperatures in limited space. Bimetallic
sensor comes in close contact with surface to be measured, providing
a very fast response time. Made of stainless steel, they are rugged and
will hold calibration indefinitely unless mishandled. Dial face (3/4 inch)
and graduations are fired ceramic on stainless steel. An ancillary pointer
is held by a magnetic clutch and indicates the highest or lowest temperature reached in a given period. It withstands vibration and jarring of
normal use and can be reset indefinitely. Ideal for testing temperatures
of electronic parts as well as heat exchangers, circulating ovens, lab
heaters, hot plates, etc. NIST certification available upon request.
14-5003-01
14-5963-02
14-5903-03
14-5903-04
14-5903-05
14-5903-06
:
°+
0 to 250°F
0 to 5OO°F
50 to 750°F
0 to 135°C
0 to 275°C '
10 to 4OO°C
Sub~:
dr. ~ ~
2°
5°
10 °
5°
5°
5°
hock
43.73
43.73
43.73
43.73
43.73
43.73
14-5695
THERMOMETERS - TANK, SCOOP-MASTER
One piece non-sparking cup-case molded out of a smooth, black,
heat and chemical resistant plastic. The cup capacity of 120 mL
meets with API and ASTM requirements. The scale is engraved on the
tube for greater accuracy. The permanently etched thermometer
tubes are furnished in Yellow Lens tubing for easier reading. Tube is
held in place by spring clips, and can be replaced without tools.
Overalllength, 355 mm.
Cat.
No.
Complete
14-5695-01
14-5605-02
14-5695-03
14-5695-04
14-5695-05
14-5695-06
14-5695-07
14-5695-08
Range,
°F/oC
Div.,
°F/°C
ASTM
No.
Each
-30 to 120°F
0 to 180°F
20 to 220°F
176 to 500°F
-34 to 49°6
-18 to 82°C
-7 to 105°C
77 to 260°C
1.O°F
1.0°F
1,0°F
20%
0.5°C
05°C
0,5°C
1.0°6
58F
59F
130F
60F
58C
59C
130C
60C
75.66
75.60
75,60
83.66
75.60
75.60
75.60
83.66
Cat.
No.
1174
Each
21.42
21.42
25.30
34.44
21.42
21.42
25.30
34.44
BACK
The 355 mm long cases are made form hardwood that is lacquered
to prevent absorption of the sample. The 100 mL capacity brass cup
is non-sparking. Thermometers are identical with those supplied with
14-5695 Seoopmaster, and are similarly mounted with easily
maneuverable spring clips.
14-5696-01
-30 to 120°F
14-5696-02
0 to 1800F
14-5696-03
20 to 220°F
14-5696-04
170 to 500°F
14-5696-05
-34 to 49%
14-5696-06
-18 to 82°C
14-5696-07
-7 to 105%
14-5696-08
77 to 260°C
Note: See 14-5700forrefills
ASTM
Noi
Replacement Thermometers- for 14-5695 and 14-5696
14-5700-01
-30 to 120°F
58F
14-5700-02
0 to 180%
59F
14-5700-03
20 to 220°F
130F
14-5700-04
170 to 50O°F
60F
14-5700-05
-34 to 49°C
58C
14-5700-06
-18 to 82%
59C
14-5700-07
-7 to 105°0
130C
14-5700-08
77 to 260%
600
14-5696
THERMOMETERS - TANK, W O O D
Range,
°F/°C
, ;Ely;,.
F/c:,
1.0°F
1.0°F
1.0°F
2.0°F
05°C
0.5°0
0.5°C
1.0+6
RSTm
~ NO
58F
59F
130F
60F
580
59C
130C
60C
+ Each
70.56
70.56
70.66
79.48
70.56
70.56
70.58
79.48
14-5936
THERMOMETERS - WEATHERING TEST
Precision thermometers manufactured according to specifications of
the California Natural Gas Association for weathering tests of fabrics
and other materials.
Cat.
No.
14-5936-01
14-5936-02
Range,
OF
0 to 45
-70 to 0
Suhdiv., Length, Immersion,
°F
mm
mm
0,2
0.5
395
345
37
115
Each
31.18
62.37
THERMOMETERS
rIMER
22-3040
HYGROMETER/THERMOMETER
- DIAL
22-3468
Provides humidity and temperature readings in an easy-to-read dJal
format. Large 6-inch diameter analog face displays 0 to 100% relative
humidity and temperature from -40 ° to 122°F (-40 ° to 50°C).
Temperature resolution is 1° and accuracy is _+1.5%. Humidity
resolution is 1%RH and accuracy is _+2.5% at 5O%RH. Ideal for
constantly monitoring labs, hallways, walk-ins, storage facilities, and
plant areas. Self-contained unit is stable, accurate and requires no
adjustment or maintenance. Supplied complete with screw for wall
mounting. Size is 6-inch diameter x 1 inch and weight is 8 ounces.
Cat
:
22-3040-01
:
:
:
Each
Dial Hygrnmeter/Therrnometer
71.22
CLOCKS - ELECTRIC, 2 4 H O U R ,
TYPE
LABORATORY
WALL
Clock has standard 12 hour black numbered outer dial with inner ring
of balance of 24 hours in red. White background. Clear plastic lens.
Diameter of dial, 12 inches. Housed in slim, 2 V2 inch deep case.
Available in quartz or regular 120 volts, 60 Hz, AC. UL listed. Quartz
clocks require one "AA" battery (not supplied).
Cat,
NQ
22-3468-02
22-3468-04
Dial dia.,
Type
Reg electric
Quartz
ini
12
12
Eech
44.78
55.78
ELECTRIC STOP TIMERS
THERMOMETER RACKS
22-3710
14-4375
THERMOMETER
T I M E R - KWIK-SET, L A B - C H R O N ,
RACK - POLYPROPYLENE
Suitable for holding up to 25 thermometers in the correct vertical
position, thus avoiding mercury separation, which often occurs when
thermometers are improperly stored. Manufactured from V4 inch
polypropylene, the rack is sturdy and will not tip. Sides have large
comfortable carry handles. The top and middle plates have 5/~6 inch
hole diameters. The bottom plate has convenient V8 inch diameter
drain holes. Overall dimensions are 8 x 10 x 5 3/4 inches deep. The
entire rack is steam autoclavable.
Cat;:
N~
14-4875-01
:
:
Descr ptlod
~::~
:
Thermometer Reck
:
::
Each,
LAB-LINE
Unit features a high torque, synchronous motor which assures
consistent accuracy regardless of voltage fluctuations or line load.
The large, illuminated timing switch requires only a light touch for
operation. Pushbutton reset instantly returns all numbers to zero;
electric brake. Steel housing is finished in baked enamel and
measures 7 x 4 x 4 inches high. With 6 foot, 3-wire cord and plug.
15-month warranty. For operation on 120 volts, 60 Hz, AC, 30 watts,
Cat.
No
22-3710-D1
T merrange
Dial divisiQa$
EaCh
To gggg.g seconds
0.1 second
311.85
30.95
1175