AC/DC Converter

Transcription

AC/DC Converter
AC/DC Converter
LO18-26C0513-03
Three-phase three wire or four wire open frame
switched-mode power supply
High isolated, ultra wide input voltage range
AC-DC converter for electric meters
FEATURES
 Ultra wide input voltage range:
65~460VAC/90~650VDC
 Any two wires connection from the three-phase





RoHS

three wire or four-wire system is available
Conduction/Radiation: Class B
Burst/Surge: Class 4
Input over-voltage protections
Output short circuit, over-current, over-voltage
protections
High efficiency, high reliability, low ripple & noise,
low standby power consumption
Long-life low-impedance electrolytic capacitors
LO18-26C0513-03----Ultra wide input voltage range open frame switched-mode power supply for electric-meter application. This AC-DC
converter is designed for electric-meter application and operates over a very wide input voltage range: 65-460VAC or 90-650VDC. It means
that this converter can operate with any two wires connection from the three-phase three wire or four-wire system. When failures happen in
the lines system resulting in input over-voltage, the converter will shut down to protect itself and the terminal devices from damage,
improving the reliability of the system. The isolation voltage is 4000VAC between input and output, and two outputs. The product meets
IEC/EN61000. So it is a design solution for electric-meter application sourced from a three-phase AC supply with the requirement of high
isolation voltage and rigorous EMC.
Selection Guide
Nominal Output Voltage and Current(Vo/Io)
Max. Capacitive Load (µF)
Part No.
Output
Power
(Vo1/Io1)
(Vo2/Io2)
(Vo3/Io3)
Efficiency
(220VAC, %/Typ.)
Vo1
Vo2
Vo3
LO18-26C0513-03
14.52W
5.6VDC/1.2A
13VDC/0.3A
13VDC/0.3A
78
5000
1000
1000
Input Specifications
Item
Operating Conditions
Input Voltage Range
Min.
Typ.
Max.
Unit
AC input
65
--
460
VAC
DC input
90
--
650
VDC
Hz
47
--
440
220VAC input, Io=100%
--
0.125
--
115VAC
--
25
--
220VAC
--
40
--
Input Over-voltage Protection
AC input
495
530
565
VAC
Leakage current
Vin=220VAC/50HZ
--
0.3
--
mA
Input Frequency
Input Current
Inrush Current
Hot Plug
A
Unavailable
Output Specifications
Item
Operating Conditions
Output Voltage Accuracy
Balance load
Line Regulation
Full load
Load Regulation
10%-100% load
Ripple & Noise*
Temperature Coefficient
Stand-by Power Consumption
Min.
Typ.
Max.
Main circuit (Vo1)
--
±2
--
Auxiliary circuit (Vo2/ Vo3)
--
±10
--
Main circuit (Vo1)
--
±0.5
--
Auxiliary circuit (Vo2/ Vo3)
--
±1.5
--
Main circuit (Vo1)
--
±2
--
Auxiliary circuit (Vo2/ Vo3)
--
±5
--
Main circuit (Vo1)
--
--
100
Auxiliary circuit (Vo2/ Vo3)
--
--
200
Main circuit (Vo1)
--
±0.02
--
Auxiliary circuit (Vo2/ Vo3)
--
±0.06
--
220VAC input, Io=0%
--
0.55
--
20MHz bandwidth
(peak-peak value)
2015.07.13-A/1
Unit
%
mV
%/℃
W
Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LO18-26C0513-03
Short Circuit Protection
Hiccup, continuous, self-recovery
Over-current Protection
110~250% Io, self-recovery
Over-voltage Protection
(Feedback-clamp) Voltage limited
Min. Load
10
--
--
Starting Time
--
650
--
--
100
--
Hold-up Time
220VAC input, Io=100%
%
ms
Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
4000
--
--
4000
--
--
Output 1-output 3
4000
--
--
Output 2-output 3
4000
--
--
Operating Temperature
-10
--
+70
Storage Temperature
-25
--
+85
Input-output
Isolation Voltage
Output 1-output 2
Test time: 1min
Storage Humidity
Altitude
Welding Temperature
--
--
90
Operating altitude
--
--
3000
Storage altitude
--
--
3000
Wave-soldering
260±5℃; time:5~10s
Manual-welding
360±10℃; time:3~5s
Switching Frequency
Power Derating
--
63
--
-10℃~0℃
3
--
--
+60℃~+70℃
3
--
--
Safety Standard
IEC60950
Safety Class
CLASS I I
MTBF
MIL-HDBK-217F@25℃ > 300,000 h
Unit
VAC
℃
%RH
m
KHz
%/℃
Physical Specifications
Dimension
100.00*50.00*35.00 mm
Weight
100g (Typ.)
Cooling Method
Free convection
EMC Specifications
EMI
EMS
CE
CISPR22/EN55022, CLASS B
RE
CISPR22/EN55022, CLASS B
ESD
IEC/EN61000-4-2 ±6KV/8KV
Perf. Criteria B
RS
IEC/EN61000-4-3 10V/m
perf. Criteria A
EFT
IEC/EN61000-4-4 ±4KV
perf. Criteria B
Surge
IEC/EN61000-4-5 ±2KV
perf. Criteria B
CS
IEC/EN61000-4-6 10 Vr.m.s
perf. Criteria A
PFM
IEC/EN61000-4-8 10A/m
perf. Criteria A
Voltage dips, short interruptions
and voltage variations
immunity
IEC/EN61000-4-11 0%-70%
perf. Criteria B
2015.07.13-A/1
Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LO18-26C0513-03
Tempera tu re Derati ng C ur ve
Outpu t Power P ercent(%)
Outpu t Power P er cen t(%)
Product Characteristic Curve
10 0
80
70
60
Inp ut volt ag e:
65 ~4 60VAC
90 ~6 50V DC
40
20
-10
0
Inpu t Voltage Dera ti ng C ur ve
10 0
80
40
65
90
70
60
Ambi ent Tem.(℃ )
Ambi ent temper atur e: 25℃
60
85
12 0
Inpu t Voltage
4 60
6 50
VAC
VDC
Note: This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
Design Reference
1. Typical application circuit
FUSE
NTC
L
+
C 1 C 2 TV S1
RL
C3
C 4 TV S2
RL
C5
C 6 TV S3
RL
AC(L) Vo 1
+
Vo2
+
N
AC ( N) Vo 3
-
Fig. 1
Model
C1/C3/C5
C2
C4
C6
TVS1
TVS2
TVS3
LO18-26C0513-03
1µF/50V
220µF/10V
120µF/25V
120µF/25V
SMBJ7.0A
SMBJ20A
SMBJ20A
Note: Output filtering capacitor C2/C4/C6 is electrolytic capacitor, it is recommended to use high frequency and low impedance electrolytic capacitor.
Capacitor withstand voltage derating should be 80% or above. C1/C3/C5 is ceramic capacitor, which is used to filter high-frequency noise. TVS is a
recommended component to protect post-circuits if converter fails.
2. EMC solution-recommended circuit
Fig. 2: Three-phase-four-wire hull-wave rectification application
2015.07.13-A/1
Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LO18-26C0513-03
Fig. 3: Three-phase-four-wire half-wave rectification application
Recommend Parameter For Higher EMC Standard Circuit
Components
Recommend Parameter
CX1/CX2/CX3
0.1μF/300VAC
MOV1/MOV2/MOV3
S20K550
F1/F2/ F3/ F4
3.15A 250V
R1/R4/R6
5-10Ω/5W
Dx
1.5A/1000V
Cx
47μF 400V
R2/R3/R5/R7
LCM
560KΩ/0.25W
>3mH
EMC solution-recommended circuit PCB layout
Three-phase-four-wire full-wave rectification application
Three-phase-four-wire half-wave rectification application
3. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to
download the Selection Guide of EMC Filter
2015.07.13-A/1
Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
AC/DC Converter
LO18-26C0513-03
Dimensions and Recommended Layout
Notes:
1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com . Packing
bag number: 58220010;
2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all
parameters in the datasheet;
3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal
4.
5.
6.
7.
input voltage and rated output load;
All index testing methods in this datasheet are based on our Company’s corporate standards;
The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model
products may exceed the requirements mentioned above. Please contact our technicians directly for specific information;
We can provide product customization service;
Specifications are subject to change without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China
Tel: 86-20-38601850-8801
Fax: 86-20-38601272
E-mail: [email protected]
2015.07.13-A/1
Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Similar documents

SIOV Metal Oxide Varistors

SIOV Metal Oxide Varistors ■ Wide operating voltage range 11 … 1100 VRMS ■ No derating up to 85 °C ambient ■ PSpice models

More information