AC/DC Converter
Transcription
AC/DC Converter
AC/DC Converter LO18-26C0513-03 Three-phase three wire or four wire open frame switched-mode power supply High isolated, ultra wide input voltage range AC-DC converter for electric meters FEATURES Ultra wide input voltage range: 65~460VAC/90~650VDC Any two wires connection from the three-phase RoHS three wire or four-wire system is available Conduction/Radiation: Class B Burst/Surge: Class 4 Input over-voltage protections Output short circuit, over-current, over-voltage protections High efficiency, high reliability, low ripple & noise, low standby power consumption Long-life low-impedance electrolytic capacitors LO18-26C0513-03----Ultra wide input voltage range open frame switched-mode power supply for electric-meter application. This AC-DC converter is designed for electric-meter application and operates over a very wide input voltage range: 65-460VAC or 90-650VDC. It means that this converter can operate with any two wires connection from the three-phase three wire or four-wire system. When failures happen in the lines system resulting in input over-voltage, the converter will shut down to protect itself and the terminal devices from damage, improving the reliability of the system. The isolation voltage is 4000VAC between input and output, and two outputs. The product meets IEC/EN61000. So it is a design solution for electric-meter application sourced from a three-phase AC supply with the requirement of high isolation voltage and rigorous EMC. Selection Guide Nominal Output Voltage and Current(Vo/Io) Max. Capacitive Load (µF) Part No. Output Power (Vo1/Io1) (Vo2/Io2) (Vo3/Io3) Efficiency (220VAC, %/Typ.) Vo1 Vo2 Vo3 LO18-26C0513-03 14.52W 5.6VDC/1.2A 13VDC/0.3A 13VDC/0.3A 78 5000 1000 1000 Input Specifications Item Operating Conditions Input Voltage Range Min. Typ. Max. Unit AC input 65 -- 460 VAC DC input 90 -- 650 VDC Hz 47 -- 440 220VAC input, Io=100% -- 0.125 -- 115VAC -- 25 -- 220VAC -- 40 -- Input Over-voltage Protection AC input 495 530 565 VAC Leakage current Vin=220VAC/50HZ -- 0.3 -- mA Input Frequency Input Current Inrush Current Hot Plug A Unavailable Output Specifications Item Operating Conditions Output Voltage Accuracy Balance load Line Regulation Full load Load Regulation 10%-100% load Ripple & Noise* Temperature Coefficient Stand-by Power Consumption Min. Typ. Max. Main circuit (Vo1) -- ±2 -- Auxiliary circuit (Vo2/ Vo3) -- ±10 -- Main circuit (Vo1) -- ±0.5 -- Auxiliary circuit (Vo2/ Vo3) -- ±1.5 -- Main circuit (Vo1) -- ±2 -- Auxiliary circuit (Vo2/ Vo3) -- ±5 -- Main circuit (Vo1) -- -- 100 Auxiliary circuit (Vo2/ Vo3) -- -- 200 Main circuit (Vo1) -- ±0.02 -- Auxiliary circuit (Vo2/ Vo3) -- ±0.06 -- 220VAC input, Io=0% -- 0.55 -- 20MHz bandwidth (peak-peak value) 2015.07.13-A/1 Unit % mV %/℃ W Page 1 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LO18-26C0513-03 Short Circuit Protection Hiccup, continuous, self-recovery Over-current Protection 110~250% Io, self-recovery Over-voltage Protection (Feedback-clamp) Voltage limited Min. Load 10 -- -- Starting Time -- 650 -- -- 100 -- Hold-up Time 220VAC input, Io=100% % ms Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation. General Specifications Item Operating Conditions Min. Typ. Max. 4000 -- -- 4000 -- -- Output 1-output 3 4000 -- -- Output 2-output 3 4000 -- -- Operating Temperature -10 -- +70 Storage Temperature -25 -- +85 Input-output Isolation Voltage Output 1-output 2 Test time: 1min Storage Humidity Altitude Welding Temperature -- -- 90 Operating altitude -- -- 3000 Storage altitude -- -- 3000 Wave-soldering 260±5℃; time:5~10s Manual-welding 360±10℃; time:3~5s Switching Frequency Power Derating -- 63 -- -10℃~0℃ 3 -- -- +60℃~+70℃ 3 -- -- Safety Standard IEC60950 Safety Class CLASS I I MTBF MIL-HDBK-217F@25℃ > 300,000 h Unit VAC ℃ %RH m KHz %/℃ Physical Specifications Dimension 100.00*50.00*35.00 mm Weight 100g (Typ.) Cooling Method Free convection EMC Specifications EMI EMS CE CISPR22/EN55022, CLASS B RE CISPR22/EN55022, CLASS B ESD IEC/EN61000-4-2 ±6KV/8KV Perf. Criteria B RS IEC/EN61000-4-3 10V/m perf. Criteria A EFT IEC/EN61000-4-4 ±4KV perf. Criteria B Surge IEC/EN61000-4-5 ±2KV perf. Criteria B CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A PFM IEC/EN61000-4-8 10A/m perf. Criteria A Voltage dips, short interruptions and voltage variations immunity IEC/EN61000-4-11 0%-70% perf. Criteria B 2015.07.13-A/1 Page 2 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LO18-26C0513-03 Tempera tu re Derati ng C ur ve Outpu t Power P ercent(%) Outpu t Power P er cen t(%) Product Characteristic Curve 10 0 80 70 60 Inp ut volt ag e: 65 ~4 60VAC 90 ~6 50V DC 40 20 -10 0 Inpu t Voltage Dera ti ng C ur ve 10 0 80 40 65 90 70 60 Ambi ent Tem.(℃ ) Ambi ent temper atur e: 25℃ 60 85 12 0 Inpu t Voltage 4 60 6 50 VAC VDC Note: This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE. Design Reference 1. Typical application circuit FUSE NTC L + C 1 C 2 TV S1 RL C3 C 4 TV S2 RL C5 C 6 TV S3 RL AC(L) Vo 1 + Vo2 + N AC ( N) Vo 3 - Fig. 1 Model C1/C3/C5 C2 C4 C6 TVS1 TVS2 TVS3 LO18-26C0513-03 1µF/50V 220µF/10V 120µF/25V 120µF/25V SMBJ7.0A SMBJ20A SMBJ20A Note: Output filtering capacitor C2/C4/C6 is electrolytic capacitor, it is recommended to use high frequency and low impedance electrolytic capacitor. Capacitor withstand voltage derating should be 80% or above. C1/C3/C5 is ceramic capacitor, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails. 2. EMC solution-recommended circuit Fig. 2: Three-phase-four-wire hull-wave rectification application 2015.07.13-A/1 Page 3 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LO18-26C0513-03 Fig. 3: Three-phase-four-wire half-wave rectification application Recommend Parameter For Higher EMC Standard Circuit Components Recommend Parameter CX1/CX2/CX3 0.1μF/300VAC MOV1/MOV2/MOV3 S20K550 F1/F2/ F3/ F4 3.15A 250V R1/R4/R6 5-10Ω/5W Dx 1.5A/1000V Cx 47μF 400V R2/R3/R5/R7 LCM 560KΩ/0.25W >3mH EMC solution-recommended circuit PCB layout Three-phase-four-wire full-wave rectification application Three-phase-four-wire half-wave rectification application 3. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to download the Selection Guide of EMC Filter 2015.07.13-A/1 Page 4 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LO18-26C0513-03 Dimensions and Recommended Layout Notes: 1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com . Packing bag number: 58220010; 2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet; 3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal 4. 5. 6. 7. input voltage and rated output load; All index testing methods in this datasheet are based on our Company’s corporate standards; The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model products may exceed the requirements mentioned above. Please contact our technicians directly for specific information; We can provide product customization service; Specifications are subject to change without prior notice. MORNSUN Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: [email protected] 2015.07.13-A/1 Page 5 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Similar documents
SIOV Metal Oxide Varistors
■ Wide operating voltage range 11 … 1100 VRMS ■ No derating up to 85 °C ambient ■ PSpice models
More information