Perclose ProGlide - Il Club del Percutaneo
Transcription
Perclose ProGlide - Il Club del Percutaneo
Perclose ProGlide Suture-Mediated Closure System Large Hole (8.5F – 21F) Closure In-Service Presentation Perclose ProGlide Suture-Mediated Closure System Device Components Needle Plunger Handle Collar SUTURE TRIMMER Lever Marker Lumen Body Foot QuickCut Link Foot (Deployed) Guide Wire Exit Port Sheath ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 1 Proximal Guide Distal Guide Marker Port posterior side of device Perclose ProGlide Suture-Mediated Closure System Pre-Close Technique • The pre-close technique using at least 2 devices must be used when closing sheath sizes from 8.5F to 21F. – The pre-close technique is when the Perclose ProGlide suture can be placed around the arteriotomy at the beginning of the procedure and knot advancement can be placed on hold until the procedure is complete. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 2 Perclose ProGlide Suture-Mediated Closure System Pre-Procedural Prep device • Flush the Marker Lumen with heparinized saline. • Must observe saline dripping out the Marker Port. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 3 Perclose ProGlide Suture-Mediated Closure System Deployment • Place a 0.038" (or smaller) guide wire through the introducer sheath. • Remove the introducer sheath while applying pressure on the groin to maintain hemostasis. • Backload first of two ProGlide devices and advance until Guide Wire Exit Port is at skin level. • Remove the guide wire before the exit port crosses the skin line. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 4 Perclose ProGlide Suture-Mediated Closure System Positioning First Device 1. With the device lever and logo facing upwards (12 o’clock), advance the device into the artery until brisk pulsatile flow is observed exiting the Marker Lumen. 2. Rotate the device approximately 30 degrees towards the patient’s right side (approximately 10 o’clock). ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 5 Perclose ProGlide Suture-Mediated Closure System Needle Deployment 1. Keeping device at 45° angle, lift the Lever to deploy the Foot (NOTE: Foot Plate should NOT be opened before rotating the device). 2. Retract the device until a tactile sensation of the Foot is felt against the anterior wall of the artery and cessation of mark occurs. 3. Depress the Plunger until the black Collar meets the purple Body. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 6 Lever Perclose ProGlide Suture-Mediated Closure System Suture Retrieval 1. Remove the Plunger using the thumb as a fulcrum. 2. Pull the suture taut. 3. Use the QuickCut or sterile scissors to cut the suture. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 7 Perclose ProGlide Suture-Mediated Closure System Foot Parking 1. Relax device and return the lever to its original position to park the Foot. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 8 Perclose ProGlide Suture-Mediated Closure System First Device Suture Retrieval 1. Withdraw device until the guidewire port exits the skin line. 2. Remove the two suture limbs. 3. Immediately place a shodded hemostat or clamp to hold the two suture limbs together at the distal end of the non-rail suture limb (shortest limb with white tip). Placing hemostat on suture limbs prevents the knot from advancing. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 9 Perclose ProGlide Suture-Mediated Closure System First Device Suture Management 1. Gently pull on the clamp until the suture is taut. 2. Place the clamped 10 o’clock suture on the right side of the patient under a sterile towel. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 10 Perclose ProGlide Suture-Mediated Closure System Device Removal 1. Reinsert the guide wire. 2. Remove device, while holding compression above the puncture site and maintaining an adequate length of guide wire inside the artery. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 11 Perclose ProGlide Suture-Mediated Closure System Positioning Second Device 1. Rotate the device approximately 30 degrees towards the patient’s left side (approximately 2 o’clock). 2. Repeat device deployment and suture retrieval steps for the second device (see pages 6-8). ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 12 Perclose ProGlide Suture-Mediated Closure System Second Device Suture Retrieval 1. Withdraw device until the guidewire port exits the skin line. 2. Remove the two suture limbs. 3. Immediately place a shodded hemostat or clamp to hold the two suture limbs together at the distal end of the non-rail suture limb (shortest limb with white tip). Placing hemostat on suture limbs prevents the knot from advancing. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 13 Perclose ProGlide Suture-Mediated Closure System Second Device Suture Management 1. Gently pull on the clamp until the suture is taut. 2. Place the clamped suture on the left side of the patient under a sterile towel. 3. Knot advancement will be placed on hold at this point and the sutures set aside under sterile towels while the operator proceeds with the procedure. 4. Device is exchanged for an appropriately sized introducer sheath. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 14 Perclose ProGlide Suture-Mediated Closure System After the Procedure 1. After completing the procedure, a guide wire should be advanced into the artery. 2. Heavily irrigate the secured ProGlide sutures with heparinized saline. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 15 Perclose ProGlide Suture-Mediated Closure System Sheath Removal 1. Remove the clamp from the first suture placed at 10 o’clock. 2. Wrap the rail suture limb around your left forefinger. 3. While maintaining guide wire access, remove the entire sheath system and simultaneously pull the rail limb with slow, consistent increasing tension. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 16 Perclose ProGlide Suture-Mediated Closure System Sheath Removal 1. Remove the clamp from the 2 o’clock suture and advance the knot using the same technique and maintaining guide wire access. 2. DO NOT lock or excessively tighten the knot while the guide wire is still in the vessel. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 17 Perclose ProGlide Suture-Mediated Closure System Assess Hemostasis 1. Assess the site for adequate hemostasis. 2. Due to the size of the arteriotomy it is usually requires knot advancement multiple times and the Suture Trimmer may be needed to obtain hemostasis. DO NOT lock or excessively tighten the knot while the guide wire is still in the vessel. 3. Once bleeding is controlled, the operator should then remove the guide wire. IMPORTANT: DO NOT remove wire if there is not adequate hemostasis. By maintaining wire access you can place additional ProGlide devices. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 18 Perclose ProGlide Suture-Mediated Closure System Assess Hemostasis 1. If acceptable hemostasis is not observed, additional Perclose ProGlide SMC devices may be deployed at this point. Repeat deployment steps. – Third device should not be rotated. The device will be deployed in a straight cranial/ caudad position (logo facing the ceiling / 12 o’clock). 2. After deployment of this device, advance the knot in the same fashion. DO NOT lock the knot or excessively tighten the knot while the guide wire remains in the vessel. 3. Assess the site for adequate hemostasis. If bleeding is controlled, the operator should then remove the guide wire. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 19 Perclose ProGlide Suture-Mediated Closure System Knot Advancement with Suture Trimmer Advance the first suture placed at 10 o’clock 1. Wrap the rail suture limb around your left forefinger. 2. Retract Thumb Knob with right hand. Place the Suture Trimmer under the suture limb making an “x” or a “cross”. 3. Slide the Suture Trimmer back to load the suture into the Suture Gate. 4. Keeping the Thumb Knob retracted, turn the Suture Trimmer coaxial to the suture and then release the Thumb Knob to capture the suture. 5. Keeping the taut rail suture limb and Suture Trimmer coaxial to tissue tract, place the Suture Trimmer under the left thumb to assume a single-handed position and complete knot advancement with slow, consistent increasing tension until the suture is taut. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 20 Perclose ProGlide Suture-Mediated Closure System Locking the Knot Lock the knot of the first suture placed at 10 o’clock first 1. With the Suture Trimmer in place and the suture taut, tighten the knot by gently pulling the non-rail (shorter, white tipped) suture limb, keeping it coaxial to the tissue tract. 2. To ensure hemostasis is achieved the knot must be locked. 3. Test for hemostasis by having the patient cough or bend his/her leg. If hemostasis has not been achieved, assume the singlehanded position for 20 seconds, or until hemostasis is achieved. 4. Secure the knot again by gently pulling on the white tipped nonrail suture limb. Repeat the knot advancement and locking steps for second suture placed at 2 o’clock. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 21 Perclose ProGlide Suture-Mediated Closure System Suture Trimming Trim first suture placed at 10 o’clock first 1. While holding both suture limbs together and pulled taut, load both suture limbs into the Suture Trimmer. 2. Keeping the thumb knob at 12 o’clock, advance the Suture Trimmer to the arterial surface. 3. Keeping the sutures taut, pull back on the red Trimming Lever to cut the sutures. 4. Keep the red lever pulled back while removing the Suture Trimmer to avoid capturing subcutaneous tissue. Repeat these steps for second suture placed at 2 o’clock. NOTE: A Suture Trimmer is packaged with each device. It is recommended to use a new Suture Trimmer to trim each set of suture limbs. ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13 22 Abbott Vascular International BVBA Park Lane, Culliganlaan 2B, 1831 Diegem, Belgium, Tel: 32.2.714.14.11 Caution: This product is intended for use by or under the direction of a physician. Prior to use, it is important to read the package insert thoroughly for Instructions for Use, Warnings and Potential Complications associated with use of this device. Information contained herein for distribution outside the U.S. and Japan only. Please check the regulatory status of the device before distribution in areas where CE marking is not the regulation in force. Tests performed by and data on file at Abbott Vascular. All drawings are artist’s representations only and should not be considered as an engineering drawing or photograph. Photo(s) on file at Abbott Vascular. Perclose ProGlide is a trademark of the Abbott Group of Companies. www.AbbottVascular.com ©2013 Abbott. All rights reserved. AP2937461-OUS Rev. B 01/13