Central Fan Catalog

Transcription

Central Fan Catalog
CENTRAL
W
NE
FAN CO.
ST
GE
AR
L
D’S
LAN
G
EN
3890 MYSTIC VALLEY PARKWAY, MEDFORD, MA 02155
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
INDEX
ITEM
PAGE
BLOWERS
Double Inlet . . . . . . . . . . . . . . .47
Duct Blower . . . . . . . . . . . . . . .23
General Industrial —
Material handling . . . . . .26, 27, 34, 35
General Purpose-utility . . . .28 thru 33
Pressure . . . . . . . . . . . . . . .27, 34
PVC-Corrosion Resistant . . .36, 37, 38
Supply or Make-Up (Roof Top) . . . .45
FANS
ALL ITEMS SHOWN IN THIS CATALOG ARE
CARRIED IN STOCK FOR IMMEDIATE DELIVERY
MANUFACTURERS OF
CENTRAL-AIRE
®
Exhaust Fans
FROM 8 TO 60 INCHES WITH SAFETY GUARDS
STOCKING DISTRIBUTOR FOR
ACME
FANTECH
PEERLESS
BROAN
FASCO
TJERNLUND
COOLAIR
LAU
VENT-AXIA
DELHI
NEW YORK
AND OTHERS
REPLACEMENT PARTS
Fan Blades
Electric Motors
Blower Wheels
Blower Shafts & Bearings
Belts
Pulleys
Attic . . . . . . . . . . . . . . . . . . .11
Bathroom . . . . . . . .15, 16, 18, 19, 20
Ceiling . . . . . . . . . . . . . . . . . .20
Darkroom . . . . . . . . . . . . . . . .21
Duct-In Line . . .16, 17, 20, 22, 23, 24, 25
Exhaust, prop. . . . . . . . . . .4, 5, 6, 7
Kitchen . . . . . . . . .16, 18, 19, 42, 43
Roof, axial up-blast . . . .BACK COVER
centrifugal up-blast . . . . .42, 43, 44
centrifugal . . . . . . . .16, 17, 40, 41
Sidewall, centrifugal . . . .16, 42, 43, 44
U.L., NFPA 96 APPROVED . . . . .42, 43
Window (Vent-Axia) . . . . . . . . . . .21
OTHER
Chemical resistance data . . . . . . .38
Curbs, roof . . . . . . . . . . . . .40, 46
Darkroom (Vent-Axia) . . . . . . . . .21
Draft inducers, duct boosters . . .12, 13
Make-up air fans . . . . . . . . . .14, 45
Motor & fan controls . . . . . . . . . .10
Relief-Supply vents . . . . . . . . . . .46
Shutters & louvers . . . . . . . . . .8, 9
Static vents . . . . . . . . . . . . . .9, 46
Special Motors . . . . . . . . . . . .5, 10
Thermostats . . . . . . . . . . . . . . .10
Vibration Isolators . . . . . . . . . . .39
General Ventilation Info . . . . . . . . . .2
General Motor Info . . . . . . . . . . . . .3
Fans & Blowers Repaired
CALL FOR PRICING.
Wholesale, distributor and OEM
discounts are quoted on request.
TERMS: Net 30 Days
We specialize in engineering practical solutions
to all ventilating problems.
Call direct to our engineering staff:
Phone: (781) 393-4456
1-800-937-4326
Fax: (781) 396-4581
www.centralfan.com
FREIGHT: F.O.B. Medford, MA
GUARANTEE: ONE YEAR
against defects in material or workmanship. We do not assume any responsibility
for incidental or consequential damages.
Details of terms and conditions; and limitations of warranty and liability available on
request.
ALL EQUIPMENT IS COMPLETELY ASSEMBLED AND TESTED BEFORE SHIPPING
PRICE $3.00
CATALOG #37
GENERAL INFORMATION
ASSUME: Air @ sea level (.075 lb/ft ), 70°F, 50% RH, 29.92 in. Hg. This is STP condition.
3
Volume varies directly
New CFM = Old CFM x
as speed:
Horsepower varies as
cube of speed:
New HP = Old HP x
Pressure varies as
square of volume:
New SP = Old SP x
Horsepower varies as
cube of volume:
New HP = Old HP x
1750 to 3500 RPM = 8 x HP
1140 to 1750 RPM = 3.6 x HP
850 to 1140 RPM = 2.4 x HP
RPM
( New
Old RPM )
RPM
( New
Old RPM )
CFM
( New
Old CFM )
CFM
( New
Old CFM )
3
2
NOISE, SOUND RATINGS, & SONES
3
Typical Sound Levels
Sones
VENTILATION OF HOODS & BOOTHS
Process
Canopy Hoods
Slotted Sides
Steam Tanks
Canopy Hood
Threshold of feeling
110
15,000 CFM blower
elevated train; chipping hammer,
loud street noise
90
90*
Noisy factory; highway auto
38
80
Shouting; noisy gathering
150–250
1500–2000
10
60
Average factory;
Average restaurant
75–150
9
50
Average office
75–125
1
40
Quiet home: average auditorium
Quiet conversation
30
Whisper
10
Sound proof room
Threshold of human audibility
75–250
100–150
200–250
Paint Spraying
Open Front Booth
Furnaces
Canopy Hood
Enclosed Booth
Laboratory Booth
Source
500,000 CFM blower
120
Canopy Hood
Island Hood
Updraft
Plating Tanks
dB
140
150
Capture
Velocity
FPM
Type of Hood
Kitchen Ranges
100–200
150–250
Open Front Booth
75–125
0
KITCHEN RANGE HOODS
1. CFM required is length x width (in feet) x velocity
as per above table.
(Depth of hood does not enter into calculations)
2. Hood should extend approximately 12 inches
beyond front and sides of range. Depth should
be two feet or more to accommodate bursts of
smoke.
3. Duct velocity can be 500 to 2000 FPM.
4. Two smaller ventilators are recommended in
place of one for more flexible operation and also
to provide ventilation should one fan fail.
Recommended ventilators for kitchen range
hoods are radial blade and backward curve
blowers.
5. U.L. classification YZHW and NFPA 96 provide
more detail.
STATIC PRESSURE LOSSES (in. H2O)
10'
.13
.31
.49
Duct Length
20'
.17
.35
.53
30'
.21
.39
.57
VEL.
FPM
1800
2000
2200
2400
2600
2800
3000
3200
3400
3600
3800
4000
4200
VP
In. Water
.202
.249
.302
.359
.421
.489
.561
.638
.721
.808
.900
.998
1.10
VEL.
FPM
4400
4600
4800
5000
5200
5400
5600
5800
6000
6200
6400
6600
6800
Recommended Ventilation Requirements
Max. occupant
Load, (persons
per 1000ft.2)
Classification
Auditorium
150
Classroom
50
CFM
per person
or area
Although fan noise is a function of a multitude of factors
the principal sources are (a) air turbulence (b) mechanical
and (c) vibration. Generally the quietest fan is also the most
mechanically efficient. Because a given fan location characteristics dictate audible noise, fan dBA cannot be guaranteed. However, relative noise levels of fans can be suitable
for considering one fan versus another.
The SONE number used in this catalog is a mathematically derived loudness (sound pressure) value as heard by
the human ear 5 feet from the inlet of the noise source in free
air (no ducts). Under these conditions, 10 SONES is twice as
loud as 5 SONES; or 20 SONES is 1/2 as loud as 40
SONES. Thus, SONE NUMBERS can be used as guides for
fan selection.
Where noise is a critical factor a more detailed, scientific analysis of the noise source and its surroundings would be
desirable. However, lined ducts, especially near the fan, provide ample sound attenuation for most clean air situations.
Also, to double the loudness (SONES) of a given fan, 13
more of the same fan must be added.
Training Shops
15
15
0.5 cfm/ft.2
Locker Room
Grease Filter
2" Mesh
Baffle
.25
.55
.25
.55
.25
.55
VP
In. Water
1.21
1.32
1.44
1.56
1.69
1.82
1.96
2.10
2.24
2.40
2.72
2.72
2.88
Education
*Max. permissible noise per 8 hr.-day
No. of
Elbows
0
1
2
VELOCITY PRESSURES
(At Std. Density .075#/Ft.3)
MOTOR RPM CHANGES & HP REQUIRED
BASIC FAN LAWS
30
20
Lounge
100
30
Dining Room
70
15
Restaurant
Offices
Conference Room
50
20
Office Space
7
20
Reception
60
20
Public Spaces
0.5 cfm/ft.2
Locker Rooms
Public Restrooms
75 cfm/closet
or urinal
Smoking Lounges
70
60
Specialty Shops
1.5/ft.2
Auto Service Stations
Beauty Salons
25
25
0.30 cfm/ft.2
Clothing Stores
1.0 cfm/ft.2
Pet Shops
Supermarkets
8
15
Sports & Facilities
Ball Rooms
100
25
Gymnasiums
30
20
Ice Rinks
0.5 cfm/ft.2
Swimming Pools
0.5 cfm/ft.2
Workrooms
ROOM SONES dBA CORRELATION
Darkrooms
0.5 cfm/ft.2
Duplicating, Printing
0.5 cfm/ft.2
SUPPLY OR MAKE-UP AIR
Unnecessary loss of summer air conditioning
or winter heating can be avoided if 80-90% of
exhaust air is supplied at or near the exhaust
hood. Make-up air appropriately introduced
into the exhaust hood need not be treated.
2
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Loudness, Sones
Based on average duct velocity of 1700 FPM.
CONVEYING VELOCITIES
Material
Sound Level dBA
CATALOG #37
www.centralfan.com
Air & Smoke
Residential
Public Buildings
Industrial
Kitchen Hood
Fine Dry Dust
Coarse Dust, Sawdust
Large Particles, Moist Material
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Duct Velocity
FPM
500–1000
1100–1500
1500–2000
500–2500
2500–3500
3000–4500
4500 & Up
MOTOR INFORMATION
Central Fan Co. uses motors that comply with EPACT (see page 10)
Follow all local electrical and safety codes, as well as the National
Electrical Code (NEC) and the Occupational Safety and Health Act
(OSHA).
TYPE OF MOTOR USUALLY REQUIRED
The great majority of small motors (1⁄2 HP & smaller) are 115 volts
single phase.
NEMA MOTOR FRAME DIMENSIONS-INCHES
Sizes of 3⁄4 to 11⁄2 are fairly divided between 208/230 volts single
phase and 208 to 550 volts 3 phase.
Sizes of 2 HP and larger are generally three phase as they are less
expensive and less troublesome than single phase motors.
1750
Frame
Size*
HP
3500
RPM
1750
RPM
1
⁄20
⁄12-1⁄3
1
⁄2-11⁄2
1
⁄8-1⁄2
3
⁄4-2
D
Shaft
Height
3
42
48
56
1
U
Shaft
Dia.
⁄8
⁄2
5
⁄8
7
⁄8
7
⁄8
11⁄8
11⁄8
13⁄8
13⁄8
15⁄8
15⁄8
17⁄8
17⁄8
1
11⁄2
3
1
2
143T
145T
5
5-71⁄2
3
5
182T
184T
10
15
71⁄2
10
213T
215T
20
25
15
20
254T
256T
30
40
25
30
284T
286T
V
2F
Shaft Parallel
Len. To Shaft
2E
Across
Shaft
BA
To First
Bolt Hole
31⁄2 slot
41⁄4 slot
47⁄8 slot
21⁄16
21⁄2
23⁄4
25⁄8
3
31⁄2
11⁄8
11⁄2
17⁄8
13⁄4
23⁄4
3
31⁄2
31⁄2
21⁄4
21⁄4
4
5
51⁄2
51⁄2
21⁄4
21⁄4
41⁄2
41⁄2
23⁄4
23⁄4
41⁄2
51⁄2
71⁄2
71⁄2
23⁄4
23⁄4
51⁄4
51⁄4
33⁄8
33⁄8
51⁄2
7
81⁄2
81⁄2
31⁄2
31⁄2
61⁄4
61⁄4
4
4
81⁄4
10
10
10
41⁄4
41⁄4
7
7
41⁄2
41⁄2
91⁄2
11
11
11
43⁄4
43⁄4
Frames without ‘T’ (preceding smaller size shaft). *3500 RPM motors are smaller.
APPROXIMATE MOTOR AMPS-1750 RPM *
HP
1
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1 Phase
115V
230V
200V
3 Phase
230V
460V
575V
3.0
4.0
5.2
7.0
1.5
2.0
2.6
3.5
.9
1.1
1.6
2.3
.8
1.0
1.4
2.0
.40
.50
.70
1.0
1
11⁄2
2
10.4
13.0
19.0
24.0
5.2
6.5
9.5
12.0
3.2
4.3
5.7
7.1
2.8
3.8
5.0
6.2
1.4
1.9
2.5
3.1
1.1
1.5
2.0
2.5
3
5
71⁄2
10
34.0
52.0
76.0
90.0
17.0
26.0
38.0
45.0
10.8
16.0
24.0
30.0
9.4
14.0
21.0
26.0
4.7
7.0
11.5
13.0
3.8
5.6
8.4
10.0
46.0
57.0
76.0
85.0
40.0
50.0
66.0
74.0
20.0
25.0
33.0
38.0
16.0
20.0
26.0
30.0
15
20
25
30
For 3600 RPM motors multiply by .90
For 1140 RPM motors multiply by 1.1
.32
.40
.56
.80
*60 Hertz
Starting amps are approximately five times running amps. Fuses
must be large enough to carry this current. Delayed action fuses of only
25% above rated current may be substituted for better protection.
NEMA VOLTAGE VARIATIONS *
Nameplate
Rating
EFFECT OF VOLTAGE IMBALANCE
A small voltage imbalance between phases will cause an abnormal
temperature rise and abnormal current. For example, temperature &
current will rise 6-10 times the voltage difference. Notify the power company if voltage exceeds 1% (2 volts at 200v).
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Suitable for line voltages
200/400
208,220 or 440
220/440
208,220,230 or 440,460
230/460
208,220,230,240 or 440,460,480
550 or 575
550 to 600
NEMA ratings are plus or minus 10% of nameplate.
*60 Hertz
Variations are suitable for fan or blower duty or other easy to start
applications only.
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
3
CENTRAL-AIRE
®
Model K Exhaust Fans
HEAVY DUTY-GENERAL PURPOSE-DIRECT DRIVE-ENCLOSED MOTOR
Quiet operating general purpose fans for ventilation of most small areas where the usual low pressure conditions exist. For long duct runs use a centrifugal blower.
Suitable for use in restaurants, bars, clubs, laundries, bakeries, barns, stores, offices, industrial plants and
electronic equipment cooling.
Moderately priced and economical in operation-Built for years of dependable service-Broad deep pitch blades
for quiet, high air delivery-Attractive design, Gray green finish. Quality is equal or superior to higher priced
fans.
• Thermally protected motors
• Variable speed operation
• Ball and sleeve bearings
• Aluminum fan blades
• OSHA type wire guards
• 125°F max. temp. of operation
General purpose exhaust fans
for most small areas.
Available with reverse air flow (suction type) at no extra charge.
Suitable for operation to 125°F—Over 125°F use a centrifugal blower
IMMEDIATE DELIVERY
MODEL K-SINGLE PHASE-115 VOLTS•
HP
1 Speed
S
Variable
Speed
Wall
V
Shutter
115 v.
Amps
Speed
RPM
0
APPROXIMATE CFM
Static Pressure (inches H2O)
1
1
3
.1
⁄8
⁄4
⁄8
*K80
*K10
1/80
1/40
X
X
X
X
A8
A10
.6
1.0
1550
1550
300
600
220
500
190
450
100
300
—
210
*K12
*K14
1/20
X
X
X
X
A12
A14
1.4
2.1
1550
1100
1000
1500
920
1300
880
1200
700
1000
450
720
1/6
X
X
X
—.
A16
1860
1800
1560
1330
1/4
X
X
—
—
A18
2900
2660
2570
2340
2100
*KB20
1/4
X
—
A20
1160
1160
1160
1160
1160
2000
*K18
2.8
2.4
4.9
3.8
3.8
3600
3400
3330
3000
2700
*KB24
1/2
X
—
A24
6.5
1160
5800
5500
5200
4600
3700
*K16
*KB16
*KB18
1/15
*115/208-230v 1Ø (Ball Bearing)
(v) Variable speed includes Solid State Control
(X) Available Model
K12
K14
16
18
71/2
8
K16
KB16
20
20
K18
KB18
3/4
15
17
14
16
11
13
1
1
19
19
18
18
22
22
105/8
13
1
1
21
21
20
20
KB20
24
13
1
23
22
KB24
30
13
11/2
27
26
3/4
⁄8
Ship
Wt.
7
12
15
20
28
30
29
32
35
51
•See p.5 for 3Ø Exhaust fans
Exhaust
Air Flow
Reverse (suction) air flow requires
motorized shutter with #C10 switch
See page 8
*Fan and shutter mount over the hole
**Add 2" for suction fan configuration
4
5
For mounting fan in opening larger than fan panel. Price
includes mounting fan and shutter on plywood (3⁄4" outdoor type) of required size painted green. Models K12K24 require next size shutter.
Dimensions (inches)
Shutter Min. Hole
B**
C
D
Round*
5
0
111/4
8
51/2
0
13
10
A
101/2
13
⁄2
MODEL K FAN AND SHUTTER ON PLYWOOD
ACCESSORIES:
Motorized shutter
Chemical resistant coating fan
Chemical resistant coating shutter
Model
No.
K8
K10
1
See Page 5 For Fans In This
Static Pressure Range
Model
No.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CENTRAL-AIRE
®
Model P Exhaust Fans
SPECIAL PURPOSE—DIRECT DRIVE—HIGH PERFORMANCE
Features include extra high outputs at higher static pressures, larger sizes,
3 phase and explosion proof motors.
•
•
•
•
•
•
Sturdy construction for years of heavy duty service
Fans may be mounted in any position
Available with plywood panels for easy window installation
Open drip proof Ball Bearing motors-1 & 2 Speed
Totally enclosed Ball Bearing motors-1 & 2 Speed
Explosion proof fans include non-sparking blade and Class I
Group D, Class II Group F and G motors (See below “caution”)
Explosion proof motors are single speed only
All fans available with reverse air flow (suction type).
Suitable for use to 125°F-Over 125°F use a centrifugal blower.
For applications with
special requirements
SINGLE PHASE: 115 VOLTS‡
Model
No.
P10
P12
P14
P16A
P16B
P18A
P18B
P20A
P20B
P24A
P24B
P24C
P30B
HP
1
⁄25
1
⁄6
1
⁄4
1
⁄8
1
⁄3
1
⁄6
1
⁄2
1
⁄4
3
⁄4
1
⁄2
1
⁄2
3
⁄4
11⁄2
Fan with safety guard.
3 PHASE: 208, 230, 460 VOLTS
With Open Motor
With Enclosed Motor
Expl. Proof*
1 Phase‡
3 Phase
1 Phase
3 Phase 1 Phase 3 Phase
1 Speed 2 Speed 1 Speed 1 Speed 2 Speed 1 Speed 1 Speed 1 Speed
S
M
T‡
S
M
T‡
SX
TX
CFM
Static Pressure (inches water)
RPM
0
1
1
⁄8
⁄4
5
⁄2
—
X
X(v)
—
—
—
1500
800
X
X
X
X
X
X
X
X
1750
1470
1350
1200
900
–0
–0
X
X
X
X
X
X
X
X
1750
2300
2100
1950
1600
1500
1400
X
X
—
X
X
X
X
X
—
X
—
X
X
X
—
X
1140
1750
2000
3150
1800
3050
1500
2800
1100
2600
800
2300
–0
2000
X
X
—
X
X
X
X
X
—
X
—
X
X
X
—
X
1140
1750
2900
4300
2600
4000
2200
3800
1700
3400
1500
3100
1300
2800
X
X
—
X
X
X
X
X
—
—
—
X
X
X
X
X
1140
1750
3600
6000
3300
5800
3000
5600
2700
5300
2400
5000
2000
4700
X
X
X
—
X
—
—
X
X
X
X
X
—
—
—
—
X
X
—
X
—
—
X
—
800
1140
1140
4800
6000
8000
4600
5800
6900
3900
5500
6200
2900
4500
5700
1800
3800
5500
1000
3400
5000
—
—
X
—
—
X
—
—
1140
11000 10500 10000
9500
9000
8100
Caution:
Explosion Proof motors and non-sparking blades are usually
required in operating environments where explosive or ignitable
gases or dust are present. Proper motor selection requires full
understanding of U.L. and N.E.C. code designations. Article 500
(N.E.C.) covers the requirements for electrical equipment and
wiring. Equipment selection and wiring is a customer (user)
responsibility. Motors and impellers misapplied in hazardous environments are dangerous to personnel and property.
Examples of some hazardous materials:
Class I (Gases, Vapors)
Group AAcetylene.
Group BButadiene, ethylene oxide, hydrogen, propylene oxide.
Group CAcetaldehyde, cyclopropane, diethyl ether, ethylene,
isoprene.
Group DAcetone, acrylonitrile, ammonia, benzene, butane,
ethylene dichloride, gasoline, hexane, methane,
methanol, naphtha, propane, propylene, styrene,
toluene, vinyl acetate, vinyl chloride, xylene.
Note: A motor rated for Class I, Group D should not be used in the presence of Group A,B or C substances; and a Class II, Group F & G motor
should not be used with Group E substances.
300
–0
(X) Available Model
Accessories:
Model
No.
P10
P12
P14
P16
P18
P20
P24
P30
Wall
Inlet Chem. Res.
Shutter Guard Coating*
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*Fan only. See page 8 for shutter
coating.
D
Opening
Nec.
(Round)
Approx.
Wt.
(Lbs.)
1
1
13
15
17
19
10
14
16
18
25
30
35
45
11⁄2
11⁄2
11⁄2
2
21
23
27
33
20
22
26
32
50
60
80
110
Dimensions (inches)
Class II (Combustibles Dusts)
Group EAluminum, magnesium and other metal dusts with similar characteristics.
Group FCarbon black, coke or coal dust.
Group GFlour, starch or grain dust.
Additionally, all hazardous location motors carry a “T code” which identifies
the maximum motor surface temp. (operating and burnout) which must be
correlated with the “minimum ignition temp.” of the hazardous substance.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
400
⁄8
X(v)
(v) Variable speed includes solid state control
480
1
⁄8
X
‡ See Pg.10 for 2 speed 3Ø, 208 1Ø and switches
*Incl. Non-sparking blade
700
3
Model
No.
A
B
C
P10
P12
P14
P16
13
16
18
20
10
11
12
13
0
P18
P20
P24
P30
22
24
30
36
13
13
14
15
⁄4
3
Model number indicates fan blade diameter.
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
5
CENTRAL-AIRE
®
Model R Exhaust Fans
ALL PURPOSE—BELT DRIVE—RUGGED WELDED CONSTRUCTION
All Purpose-Belt Drive-Rugged Welded Construction
An all purpose high performance fan suitable for ventilation of most large areas requiring dependable ventilation.
Large selection of speeds and motors to choose from to cover a wide range of commercial and industrial requirements.
Recommended for ventilation of stores, halls, offices, restaurants, garages, barns, air conditioning equipment
rooms and all types of industrial buildings.
Moderately priced yet built for years of dependable service.
WARNING:
OSHA guards recommended
when installing fan within
7' of floor.
SEE page 7
IMPORTANT FEATURES
•
•
•
•
•
•
•
All purpose exhaust fans
for most large areas.
SPECIFY EXHAUST
OR SUCTION
Quiet operation-High air output-Slow speed.
Flexible choice of speeds and motors available.
Easy and economical motor replacement if necessary.
Ball Bearing throughout-motor & fan.
Generously sized belt drive for trouble free operation.
Heavy duty propellers, designed for low static and high air volume…either exhaust or suction.
Not designed for motor reversing operations.
WITH OPEN MOTOR-WHEN ORDERING: SPECIFY LINE VOLTAGE AND PHASE
Model
R24
R30
R36
B
C*
D
E
F
C
D*
E
F
G
D
E*
F
G
H
Single Phase**
Three Phase
Approx. Tip
1 Speed 2 Speed 1 Speed 2 Speed Wall
Fan Speed Noise
S
M
T
R
Shutter RPM
FPM Rating
HP
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1
⁄3
1
⁄2
3
⁄4
1
11⁄2
1
⁄2
⁄4
3
1
11⁄2
2
3
⁄4
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
–
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
R42
E
F*
G
H
J
1
11⁄2
2
3
X
X
X
X
X
R48
F
G*
H
J
K
1
11⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
R54
G
H*
J
K
11⁄2
2
3
5
X
X
X
–
–
–
–
–
X
X
X
X
X
X
X
X
R60
H
J*
K
L
2
3
5
71⁄2
X
X
–
–
–
–
–
–
X
X
X
X
X
X
X
X
*Recommended for most commercial and industrial applications.
See page 10 for special motors. (X) Available models
**Single Phase 120v or 230v. See p.10 for 208v 1Ø.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
0
1
⁄8
1
⁄4
3
1
⁄8
5
⁄2
⁄8
540
600
690
750
850
3390
3770
4335
4710
5300
A
A
B
C
D
4800
5300
6000
7000
8000
3900
4600
5400
6400
7500
3100
4300
5600
6800
2800
3800
5400
3100
4300
3600
460
480
530
570
640
3770
4080
4710
5100
5890
A
A
B
C
D
7000
8000
9000
10000
12000
5700
6900
8100
9200
11300
4600
6500
8000
10300
4200
5400
8200
4400
6500
5300
480
600
620
700
760
3770
4712
5655
6597
7540
A
B
B
C
D
10000
12000
14000
16000
18000
8200
10300
12600
14700
17000
6900
10100 6400
12800 8600
15500 12200
7100
9800
7900
A42
400
480
520
600
670
3848
4398
5497
6322
7147
A
B
B
C
D
16000
18000
20000
22000
25000
13100
15400
18000
20200
23500
10400
14400 9200
17600 11900 9700
21500 17000 13500 11000
A48
400
460
500
580
650
3770
4712
5684
6597
8167
A
B
B
C
D
21000
24000
26000
30000
36000
17200
20600
23400
27600
33800
13900
16200 13200
24000 16200 13200
30900 24500 19500 16000
A54
300
350
420
500
4241
4948
5655
6361
A
B
B
C
27000
30000
35000
42000
23200
27000
32200
39500
15600
21600 13800
28000 18900 15400
36000 28500 22000 18500
A60
270
300
375
470
4271
4712
5890
6744
A
B
B
C
34000
41000
48000
55000
30600
37000
45000
53000
24500
32800
41000
49000
A24
A30
A36
See page 10 for motor controls.
18600
22100 18000
34000 27000 22000
44000 38000 33000
NOISE RATING
Applications
Dimensions & Accessories:
See next page
6
CFM
Static Pressure (inches water)
CATALOG #37
www.centralfan.com
Residences, Churches, Schools, Libraries
Stores, Offices, Hall, Restaurants
Laundries, Bakeries, Bowling Alleys
Very noisy locations
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Rating
A
A or B
B or C
B,C, D
CENTRAL-AIRE
®
Model R Exhaust Fans
DIMENSIONS (INCHES)
Panel Approx.
Sq.
Depth
A
B*
Model
No.
C
Shutter Opening Min.
(Sq.) Req. (Rd.) Wall
D
O*
W**
Approx.
Wt.
Lb.
24
30
36
42
30
36
42
48
14
15
16
17
11⁄2
2
21⁄4
21⁄2
27
33
39
45
26
32
38
44
6
7
8
10
70-100
90-120
100-140
130-150
R 48
R 54
R 60
54
60
66
18
27
27
21⁄4
2
2
51
57
63
50
56
62
12
14
16
160-200
270-320
390-470
R
R
R
R
Model number indicates fan blade diameter.
*Allows venturi penetration of wall.
**Shutter blades will flutter if fan blade is too close to shutter.
“W” dimension must be increased for higher RPM or where quieter operation is desired.
OSHA COMPLIANT FAN GUARD
20 gauge galvanized steel panels, expanded metal grille. Bolt together guards
shipped unassembled (mounting hardware included). Heavy gauge panels bolt
together to form housing. Grille fastens to housing with screws supplied. Guard
can be mounted directly to fan frame or wall.
GUARD DIMENSIONS
A
B
Depth
C
Ship
Wt.
24
30
36
42
30
36
42
48
30
36
42
48
20
20
30
30
35
40
60
90
R 48
R 54
R 60
54
60
66
54
60
66
32
34
37
120
200
256
Model
No.
R
R
R
R
ACCESSORIES
Model
R
R
R
R
#
*
**
Inlet
Guard
Motorized
Shutters
115 or
230 V #440V
Chem. Resis. Coating
Fan and Automatic
Motor
Shutter
Motor*
Two**
Disconnect
Speed
Switch
Controls
24
30
36
42
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
R 48
R 54
R 60
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
440V uses 115/230V motor with a transformer.
Mounted to fan panel.
All without overload protection (limited availability for larger HP’s see page 10).
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
7
Model A Aluminum Wall Shutters
AUTOMATIC-MOTORIZED-CHAIN OPERATED
EXTRA HEAVY DUTY FRAMES FOR DIMENSIONAL STABILITY
Model A
Model
No.
•
Frame is .080 x 1.50 extruded aluminum with mill finish & welded corners.
•
Aluminum blades are 26 gauge with 20 gauge galvanized reinforcement strip across
top of blade & felt seal on leading edge of blade for quiet closing.
•
Stainless steel bearings and pivot pins for extended life.
•
POSITIVE ACTION MOTORIZED SHUTTERS: Motor is securely bolted to frame.
Special linkage operates center rod for uniform and positive operation.
•
CHAIN OPERATED: For manual operation; coil spring positive closing.
Nominal
Dim. (Sq.)
I.D. O.D.
A
B
2600
FPM
Max
CFM
Automatic
Motorized**
Gravity 115 or
Operated 230 V.
440 ≠
Model A Motorized
Chain
Operated
A
A
A
A
8*
10
12
14
8
10
12
14
11
13
15
17
1150
1800
2600
3500
X
X
X
X
–.
X
X
X
–.
X
X
X
X
X
X
X
A
A
A
A
A
16
18
20
24
30
16
18
20
24
30
19
21
23
27
33
4600
5850
7200
10400
16250
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
A
A
A
A
A
36
42
48
54
60
36
42
48
54
60
39
45
51
57
63
23400
31850
41600
52650
65000
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
SIDE VIEW
AIR FLOW
FRONT VIEW
5
*Steel frame with 1 ⁄8 flange….this size only
**Also available as power close, fail open (for
elevator machine rooms). Maximum UPS ship size is A36, B36 ≠ 440V uses 115/230V motor
with a transformer
(X) Available models
Also available
DELAY SWITCH….MOUNTED ON SHUTTER
PROTECTIVE COATING
Motorized shutter will not open against substantial fan induced air flow. Delay switch should be
used to allow shutter to open fully before fan becomes operational. For 1Ø or 3Ø applications.
Delay Switch Model C10
Air Dry PVC Coating
.
Models A,B or BS
Model B Roof Fan Shutters
Flange-less steel frame-Felted aluminum blades-Can be used inside ducts. Opens in direction of air flow. Curb drop in type to
prevent backdraft when roof fan is not running. Sized to fit onto shelf of roof curb.
Model
No.
Nominal To 1500
O.D.
FPM Automatic
+0 - 1⁄8
Max.
Gravity
(Square) CFM
Operated
B
B
B
B
B
9
10
12
14
15
9
10
12
14
15
800
900
1300
1800
2100
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B
B
B
B
B
B
16
18
20
22
24
28
16
18
20
22
24
28
2400
3100
3900
4800
5700
7800
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
B
B
B
B
B
30
32
36
39
42
30
32
36
39
42
9000
10000
13000
15000
17900
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
20
24
28
321⁄2
391⁄2
3100
4800
7000
9000
14000
X
X
X
X
X
–
–
–
–
–
–
–
–
–
–
BS
BS
BS
BS
BS
18
22
26
30
37
(X) Available models
8
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Motorized
115 or #440V
230 V.
CATALOG #37
www.centralfan.com
#440V use 115/230V motor with a transformer
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
STATIONARY LOUVERS
• Extruded .081 aluminum alloy construction.
• Drainable blades-Falling water is drained to the side, removing cascading
water droplets from the air stream.
• Mitered corners for dimensional stability.
• Expanded 1⁄2" screen interior mounted. (insect screen optional)
• 11⁄2" flange is standard (channel frame optional).
• Standard mill finish (optional Baked Enamel, Kynar, Anodized).
• 4" deep frame (6" Available).
IN STOCK SIZES
Stock
No.
S61
Nominal
Size* (in.)
12 x 12
Free Area (ft2)
0.23
Intake
CFM**
250
Ship
Wt. Lbs.
9
S62
14 x 14
0.38
400
10
S63
16 x 16
0.53
570
12
S64
18 x 18
0.78
850
14
S66
24 x 24
1.64
1750
21
S67
30 x 30
2.81
3000
29
S68
36 x 36
4.31
4600
40
*Suggested hole size (Louver dimension
**max. cfm before
w/o flange 1⁄4" less)
Max. single section 96" x 96". For larger sizes
use multiple sections.
Other sizes and shapes, etc. Special Order
water penetration
begins (1075 FPM).
CUSTOM ORDER LOUVERS AND DAMPERS
COMBINATION LOUVERS
• Combination louvers integrate stationary blade and adjustable
blade construction in a single frame.
• All the features and options of stationary models.
• Blade edge gaskets.
BACKDRAFT DAMPERS
• .064 aluminum construction.
• Nylon bearings with Delrin pivot pins.
• PVC foam gasketed blades.
• Full 90 degree operation.
• Rear mounted exposed linkage.
• Flange and channel models available.
• Wide variety of manual, electric or pneumatic operators.
• Custom made to order maximum single size is 72" W x 96" H.
For larger sizes use multiple sections.
• Intake and exhaust installations.
• Vertical and horizontal models.
• Custom made to order maximum single size is
36" W x 72" H.
For larger sizes use multiple sections.
CONTROL DAMPERS
• Available in 13 ga. aluminum and 16 ga. steel
construction.
• Opposed blade and Parallel blade models.
• PVC foam gasketed blades.
• Low leakage models with stainless steel jam seals.
• Concealed end linkage.
• Wide variety of manual, electric or pneumatic
operators and operator accessories.
• Custom made to order.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
9
Motor Controls for Fans & Blowers
SINGLE SPEED CONTROLS
Manual
Type
Cat.
No.
Phase
Dimensions
Nema
Size
Poles
Fig.
H
W
D
Without
Overload
6810-G
7810-GD
1
3
2
–
2
71⁄2
–
10
1
1
2
3
A
A
4
4
21⁄4
21⁄4
21⁄2
21⁄2
Exp. Prf.
6810-E
1
1
2
–
00
1
B
63⁄4
31⁄2
43⁄4
B
3
1
43⁄4
Exp. Prf.
Fig. A
Maximum HP
208
460
115V
230
550
3
7810-E
1
7 ⁄2
–
10
00
3
6 ⁄4
3 ⁄2
TWO SPEED CONTROLS
Without
Overload
Protection
27956
2512KG22
C61
C62
27940
3 (2 Wdg.)
3 (2 Wdg.)
1
1
1
1/3
3/4
1
1/2
7 1/2
1/3
3/4
1
10
-
00
1
00
00
00
3
3
1
2
2
C
A
C
C
C
4 1/4
4 1/4
4 1/4
4 1/4
4 1/4
2 1/8
4 5/8
2 1/8
2 1/8
2 3/4
2 3/8
2 3/8
2
2 3/8
2 1/2
JV2
JV5
3 (1 Wdg.)
3 (1 Wdg.)
-
3
5
3
5
1
1
3
3
D
D
8
8
3
3
3 1/2
3 1/2
SOLID STATE VARIABLE
CONTROL
LINE VOLTAGE THERMOSTATS (1Ø)
Fig. B
Max HP
Max Motor Amps
Temp ºF
115V 230V 115V
230V Range
Diff
Model
Type
C73
C74
C74A
C76A
C77*
Heat/Cooling
Cooling (Attic)
Cooling (Attic)
Heat/Cooling
Heat/Cooling
3
⁄4
3
⁄4
–
3
⁄4
–
11⁄2
11⁄2
–
11⁄2
–
13.8
13.8
4.4
13.8
16
10
10
–
10
8
50-90
90-130
50-120
40-110
30-110
Switch
Type
2°
SPST
15°
SPST
15°
SPST
3°
SPDT
3° SPDT/SPDT
(Shaded Pole or Perm. Cap. Motors)
SINGLE PHASE
Model No.
C64
C65
C75
277V
C64-3
C65-3
*2-stage (2speed or 2 motors).
Fig. C
MOTOR DISCONNECT SWITCHES
HP
3
⁄4
1-2
3
5
71⁄2-10
Fig. D
*
Single Phase
1 Sp. 2 Sp.
X
X
X
X
X
–
–
–
–
–
460V-550V only
Three Phase
1 Sp. 2 Sp.
X
X
X
X
X
X
X
X
X*
–
(
Volts
Amps
120
6
120
10
230
6
277
6
3-wire control
for constant 115v
INPUT POWER SAVING (RPM CONTROL)
A significant reduction in energy consumption is realized when centrifugal fan
speeds are reduced only slightly. In applications where maximum demand volume
is not constant (VAV Systems), RPM control with inverters (variable frequency)
could result in considerable reduction in power consumption. (Fan power demand
varies with RPM3)
Analysis of each fan application will determine the suitability of various volume
control methods (Dampers, inlet vanes & inverters). Inverters available special order.
(X) Available
The Energy Policy Act (EPAct) took effect October 24, 1997. This law mandates efficiency standards for general purpose, three phase, 2,4 and 6 pole
AC motors from 1 to 200 horsepower manufactured for sale in the U.S. Many motors such as explosion proof, two speed, TEFC, single phase and others, are excluded. Central Fan will provide motors that comply with the mandate when applicable.
SPECIAL MOTORS
Two Speed
2 Winding
1 Wndg
1750/1140
1800/900
Special Enclosures
Enclosed
Expl. Proof
1750 or 3450
1750 or 3450
208v 1Ø ODP
277V
1Ø ODP
RPM
RPM
*High
Efficiency
1Ø
ODP
X
X
3Ø
ODP
–
–
3Ø
ODP
–
–
1Ø
X
X
3Ø
–
X
1Ø
X
X
3Ø
–
–
1750
–
X
3450
–
X
1725/1140
–
–
1750
–
X
1750
–
–
3450
–
–
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
1
11⁄2
X
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
X
2
3
–
–
X
X
X
X
X
–
X
X
–
–
X
X
X
X
X
–
–
–
–
–
X
X
X
X
5
71⁄2
–
–
X
–
X
X
–
–
X
X
–
–
X
X
–
–
–
–
–
–
–
–
X
X
X
X
HP
1
⁄4
1
⁄3
1
⁄2
3
⁄4
Note: 2-sp. XP motors not available.
See page 5 for expl. proof motor description.
* High efficiency motors suitable for use with VFD controls.
Note: All single phase ODP motors are not readily available marked for 208v 1Ø. (115v is std.) (X) Available
10
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
)
Residential Attic Fans
IMPORTANT FEATURES
Fan size selected should be capable of changing the entire volume of a
home in approximately two minutes. (Do not include the attic space unless
used for living .)
• Slow speed belt driven for quietness
• Ball bearing fan & motor-permanently lubricated
• Compact construction with no unnecessary weight
An average size home will require a 30 inch fan.
Operation with a time switch is recommended. Turn fan on for hours desired
and forget it. Fan shuts off automatically.
• Two types to choose from
• Single phase-115 Volts ODP
Time switch installs in single gang switch box. Two speed operation affords
additional flexibility. Two speed & timer switches in double gang box.
Atlas Wall Fans
Recommended for their quietness of operation. For attic window or wall installation in
homes with reasonably air tight attics. Two smaller fans may be used if space is not available for one large fan.
Fan installs against wall opening on the inside and the shutters on the outside. Shutters
close automatically when the fan stops, keeping rain, wind and insects out.
Ceiling opening may be used as an access to the attic if ceiling shutters are placed on
the attic floor unfastened.
FAN
Model
No.
R24B
R30C
R36D
R42E
HP
White
Motorized Two
1 Speed 2 Speed
Wall
Ceiling
Speed
S
M
Shutter Shutter* Switch
1
⁄4
⁄3
1
⁄2
3
⁄4
X
X
X
X
1
X
X
X
X
A24
A30
A36
A42
EM24
EM30
EM36
EM42
X
X
X
X
DIMENSIONS (inches)
Fan
RPM
Air
CFM
Volume
of home
(Cubic ft.)
540
480
400
350
4800
7000
10000
16000
9600
14000
20000
32000
Fan
O.D. Sq.
30
36
42
48
Fan
Wall Wall Shutter
Depth Opening Rd. O.D. Sq.
14
15
16
17
26
32
38
44
27
33
39
45
Wt.
Lb.
60
70
90
110
*Motorized ceiling shutters are recommended if attic space is not air tight. Ceiling shutter dimensions are shown with Lay Down Fans. See page 7 for safety guards.
(X) Available models
Twelve hour timer switch available.
Atlas Lay-Down Fans
Easily installed-Simply cut hole in attic floor over hallway, Lay Down fan over this
opening on top of sound absorbing plastic strips and install shutter on ceiling below.
Sufficient vent area must be provided to let the hot air out of the attic through
louvers on wall, vents under the eaves, or in ridge.
Aluminum shutters fit flush with ceiling.
Fan may be pulled up through ceiling opening.
Most economical installation is ceiling shutter not motorized.
FAN
Model
No.
RS24B
RS30B
RS36C
RS42C
HP
Gravity
White
Two
1 Speed 2 Speed Ceiling
Speed
S
M
Shutter* Switch
1
⁄4
⁄4
1
⁄3
1
⁄3
1
See page 7 for safety guards.
X
X
X
X
X
X
X
X
E24
E30
E36
E42
*Baked white enamel
Dimensions (Inches)
Fan
RPM
500
400
340
280
X
X
X
X
(X) Available models
Air
CFM
Volume
of home
(Cubic Ft.)
Fan
O.D.(Sq.)
Fan
Height
9000
13000
18000
24000
30
36
42
48
14
15
16
17
4500
6500
9000
12000
Min. Vent
Shutter
Ceiling Area Req.
Flange O.D. Opening (Sq. in.)
26
32
38
44
24
30
36
42
884
1248
1728
2300
Fan
Wt.
Lb.
60
70
80
90
Twelve hour timer switch available.
Central-Aire Attic Cooling Fans
FOR COOLING HOT ATTICS & REDUCING AIR CONDITIONING COSTS
For easy to install sidewall installation.
Complete with shutter and adjustable thermostat.
Safety inlet guard.
Lifetime lubricated quiet motors.
Model
Blade
Dia.
Max. attic
floor area
Sq. Feet*
CFM
HP
K12AF
K14AF
K16AF
12"
14"
16"
1000
1500
2000
1000
1500
2000
1
⁄20
1
⁄15
1
⁄8
Amp. RPM
1.4
2.1
2.4
Recommended setting for thermostat is 100 Degrees. (Shuts off at approx. 90)
*1 CFM per ft2 of attic for summer venting.
Recommended air intake area is exhaust CFM ÷ 300 = req. ft2
**
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
1500
1100
1100
Fan
O.D.
Opening
(Sq.) Nec. (Sq.)**
16"
18"
20"
13"
15"
17"
Ship
Wt.
Lb.
16
20
28
Optional humidistat
UL
120V 7.5 amps (max.)
adjustable setting Model PH
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
®
11
DRAFT INDUCERS
FOR VERTICAL VENTING
[See page 14 for make-up (combustion) air devices.]
DRAFT INDUCER SELECTION TABLE
TJERNLUND AUTO-DRAFT INDUCERS
assure positive draft when restricted boilers and furnaces, poor chimneys or negative pressures in building prevent proper
exhaust of combustion gas. The Venturi
action of Tjernlund Auto-Draft Inducers
starts air moving up the stack instantly,
keeps it moving smoothly. These units are
adaptable to all heating systems. They are
quick and easy to install and completely
automatic in operation. Tjernlund's unique
design and careful construction makes
them trouble-free and reduces maintenance to a minimum. The Vari-Draft
Control permits adjustment to the individual
job requirement.
Pipe
Size
In.
Heater
270°F
BTU Flue Gas
Input S.P. CFM
Model
No.
DJ-3
D-3
NOTE:
1. Inputs shown above are believed
to be maximum capacities for
inducers, when mounted on pipe
sizes shown for ordinary jobs
where a moderate amount of
mechanical induced draft is
required.
2. Consideration is given to typically
higher static pressure requirements for larger installations, for
the type of fuel burned, and for
the type of draft control installed.
3. Where pressure requirements
are unknown, or believed to be
unusually severe, ask for complete performance curves or consult factory.
DUCT BOOSTER
MODEL DB-2
®
I
IL
Heater
390°F
BTU Flue Gas
Input S.P. CFM
Heater
BTU
Input
530°F
Flue Gas
S.P. CFM
69000 .034
48
72000 .047
36
58000 .048
33
4
105000 .042
72
109000 .053
55
92000 .057
48
5
111000 .043
72
104000 .052
52
74000 .052
39
6
100000 .041
68
34000 .042
17
25000 .035
13
5
270000 .063
190
330000 .085
166
295000 .092
163
6
356000 .073
246
377000 .090
190
300000 .093
169
7
360000 .075
259
330000 .085
166
230000 .080
118
8
320000 .068
217
222000 .075
110
123000 .065
65
8
900000 .125
590 1200000 .143
603 1100000 .147
566
9
1110000 .135
765 1330000 .150
653 1100000 .148
566
10
1250000 .140
850 1260000 .145
615
840000 .136
440
12
1030000 .128
710
357
400000 .100
211
9
1460000 .145 1010 1970000 .175
989 1700000 .180
900
10
2080000 .170 1370 2460000 .185 1240 1900000 .180
1010
12
1920000 .160 1325 2230000 .182 1120 1500000 .170
789
14
1840000 .159 1270 1470000 .158
18
XL
Oil Firing
With
Bar. Draft
Control
3
16
HD
The Tjernlund Duct Booster is the
ORIGINAL money saving and energy efficient residential booster fan. It
increases the comfort level in hard
to heat or cool areas. No need to
adjust the whole house thermostat
or install auxillary heating or cooling
equipment. Fits round or flat forced
air heating/cooling ductwork. DB-2
features: easy installation, durability,
economical price and manual or
automatic operation. Boosts air flow
up to 275 CFM (8” duct).
Gas Firing
With
Bar. Draft
Control
Gas Firing
With
Draft Hood
710000 .115
740
825000 .135
453
184
900000 .120
620
650000 .113
340
350000 .095
650000 .099
450
440000 .095
220
200000 .075
106
16
4000000 .250 2760 4000000 .260 2010 3300000 .230
1763
18
3900000 .240 2650 3250000 .240 1660 2100000 .190
1103
20
2800000 .195 1935 2100000 .175 1079 1200000 .150
626
24
1500000 .150 1035 1100000 .125
503000 .110
266
20
5300000 .290 3690 5200000 .270 2440 3600000 .240
1870
24
3500000 .220 2415 3750000 .220 1680 2900000 .218
1550
527
MODEL D-3
MODEL I
®
Model PS 1505 Proving Switch (Available as accessory. Recommended)
Detects failure of motor or impeller & shuts off unit. (@ negative 0.05" w.c.)
Universal Control UC-1
Used in conjunction with PS1505 eliminates control circuit compatibility issues. The
UC-1 interlocks with dry contacts, 24VAC or 115V appliance control systems.
Simply connect the PS1505 to UC-1 and select the system voltage required.
Adjustable pre and post purge is also available. UC-1 can replace any relay or
timer/relay previously installed.
CLEAN AIR ONLY
DO NOT USE IN FLUE
Model
No.
DJ-3
Therm
Volts HZ RPM Watts Amps Prot.
115
1550
35
D-3
115
60
1550
I
IL
115
60
1725
1
XL
115
230
60
1725
3
HD
208
230
460
60
DB-2 DUCT BOOSTER
12
60
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
.43*
Unit
Dimensions (in)
H
D
X
Y
Ship
Wt.
57⁄8
25⁄8
75⁄8
8 lbs.
—
71⁄2
81⁄2
1
1
⁄8
141⁄2
Slot
W
1
⁄8
85⁄8 10 lbs.
4
41⁄8
123⁄4 31 lbs.
15
34 lbs.
17
⁄2
131⁄2
143⁄4
YES
187⁄8
181⁄2 101⁄2
51⁄8 163⁄4 53 lbs.
NO
27
163⁄4 25
6
74
.96
YES
⁄4HP
5.4
YES
⁄4HP
10.8
5.4
1725 2 HP
6.3
6.4
3.2
9
1
⁄2
9
7
83⁄4
10
3
241⁄2 176 lbs.
* Impedance protected
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
TJERNLUND PRODUCTS, INC.®
SIDE WALL VENTING
See P. 13 for make-up (combustion) air devices
FLUE GAS TEMP 600°F MAX. @ POWER VENTER
(DO NOT USE ON CONDENSING FURNACES)
HS-Series with Universal Control (UC-1)
UL
®
For all your gas and oil sidewall power venting needs. The UC-1
interlocks with dry contact 24VAC or 115V appliance control systems. UC-1 can replace any relay or timer/relay previously installed.
Adjustable pre & post purge, prover switch circuit and LED status
diagnostics indicators are all included. Accessories available for
multiple appliance control. (HSJ not recommended for oil).
Maximum Pipe Length (FT)
At Stack Temp
Inlet/
Outlet
Dia.
Model
Numbers
Vent
Pipe
BTU/HR
Input
4"
HS1
115V
1.76 amps
100'
100'
100'
23'
4"
150,000
200,000
250,000
300,000
100'
87'
40'
4'
60'
57'
12'
–n
35'
27'
–n
–n
6"
150,000
200,000
250,000
300,000
100'
100'
100'
30'
100'
100'
92'
–n
100'
100'
–n
–n
350,000
400,000
450,000
500,000
550,000
600,000
100'
100'
100'
100'
94'
15'
100'
100'
100'
72'
–n
–n
100'
100'
67'
–n
–n
–n
350,000
400,000
450,000
500,000
550,000
600,000
100'
100'
100'
100'
100'
67'
100'
100'
100'
100'
–n
–n
100'
100'
100'
–n
–n
–n
4"
6"
HS2
115V
2.0 amps
HS-3
100'
100'
100'
35'
4"
Inlet
Outlet
Dia.
Model
Numbers
Oil
Fired
500°F
50,000
75,000
100,000
125,000
HSJ
115V
1.76 amps
Gas
Fired
300°F 400°F
Maximum Pipe Length (FT)
At Stack Temp
Not
Recommended
n
Vent
Pipe
Dia.
25%
Dilution 400°F
Gas Fired
Power Burner
With
Barometric
Draft Control
8"
450,000
500,000
600,000
700,000
100'
100'
100'
7'
100'
100'
100'
100'
10"
450,000
500,000
600,000
700,000
100'
100'
100'
21'
100'
100'
100'
100'
8"
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
100'
100'
100'
70'
32'
5'
100'
100'
100'
100'
100'
100'
10"
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
100'
100'
100'
100'
97'
14'
100'
100'
100'
100'
100'
100'
12"
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
100'
100'
100'
100'
100'
34'
100'
100'
100'
100'
100'
100'
1,200,000
1,400,000
1,600,000
1,825,000
100'
100'
100'
29'
100'
100'
100'
100'
1,200,000
1,400,000
1,600,000
1,825,000
100'
100'
100'
72'
100'
100'
100'
100'
1,200,000
1,400,000
1,600,000
1,825,000
100'
100'
100'
100'
100'
100'
100'
100'
8"
115 VAC
1
⁄4 HP
3.2 AMP
HS-4
8"
115 VAC
1
⁄3 HP
6.3 AMP
6"
8"
BTU/HR
Input
100%
Dilution 300°F
Gas Fired
Atmospheric
With
Draft Hood Or
Draft Diverter
10"
HS-5
115/208/230 VAC
1 HP
6.2 AMP @ 208
6.3 AMP @ 230
13.1 AMP @ 115
10"
12"
14"
Accessory Controls
VH1-3-4-6
Model
VH1-8-10
HIGH TEMPERATURE VENT HOOD
Description
MAC-1E
To interlock 1 additional appliance
MAC-4E
To interlock 3-5 additional appliances
WHK-E
To interlock a millivolt water heater
NOTE: INSTALLATION MUST COMPLY WITH APPLICABLE CODES.
Dimensions
A Dia.
B
C
VH1-3
3"
VH1-4
4"
VH1-6
6"
Model
D
E
F
G
Rough-In
Dimensions
5 ⁄4"
7 ⁄4"
6 ⁄4" sq.
Ship
Wt. Lbs.
Water Heater Vent Kit
4
Water heaters rated at 50,000 BTU/hr. or less can be
vented by the VP-2. Water heaters rated from 51,000
to 120,000 BTU/hr. can be vented by the VP-3. Both
packages come complete except for the pipe.
6 ⁄4" sq.
1
8 ⁄2"
10"
71⁄2" sq.
71⁄8"
13"
85⁄8"
73⁄8" 11"
8" sq.
7
81⁄2" dia.
77⁄8"
12"
91⁄2" 101⁄2" 10"
9" dia.
6
1
10"
1
3
3
VH1-8
8"
151⁄4"
9"
183⁄8"
20"
–
–
81⁄2" dia
12
VH1-10
10"
151⁄4"
9"
183⁄8"
20"
–
–
101⁄2" dia
13
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
13
Tjernlund Products, Inc.
A cost effective way to ensure adequate combustion air for
maximum performance of heating appliances. The IN-FORCER
can be ducted up to 100 ft. allowing isolated mechanical rooms to
be supplied with outdoor combustion air. Optional control panel
allows interlock with up to 4 additional appliances.
Where the IN-FORCER supplies combustion and dilution air
each appliance must be electrically interlocked and supplied at the
rate of 50 CFM per 100,000 Btu/hr.
IN-FORCER MODEL APPLICATION CHART
Model
PAI-5*
5.4
Amps
115v
PAI-6*
5.8
Amps
115v
Not Applicable
Multiple IN-FORCERS may be installed for capacities larger than shown on chart. IN-FORCERS may be roof or wall mounted.
DIMENSIONS
*Universal Control Model UC-1
The UC-1 interlocks mechanical draft and combustion air systems with gas/oil
fired heating equipment. It can be activated by an 18-130 VAC heater control
signal, pressure switch or relay using a 5 VAC control supplied by dry contacts.
A UC-1 is needed with all PAI systems.
Accessory Controls
Model
Description
MAC-1E
To interlock 1 additional appliance
MAC-4E
To interlock 3-5 additional appliances
WHK-E
To interlock a millivolt water heater
14
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
PAI-7
Not Applicable
PAI-6
12.6
Amps
115v
6.3/6.2
Amps
208/230
Gas
Power Burner
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
6
98
6
100
8
100
8
100
8
100
8
100
8
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
PAI-5
1.5
Amps
115v
Oil Flame Retention
With Barometric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
6
100
8
100
8
100
8
100
8
100
8
95
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
PAI-4
PAI-4*
150,000
200,000
250,000
275,000
300,000
350,000
400,000
450,000
500,000
550,000
600,000
650,000
700,000
775,000
850,000
900,000
950,000
1,000,000
1,200,000
1,300,000
1,400,000
1,500,000
1,600,000
1,700,000
1,800,000
1,900,000
2,000,000
2,100,000
2,200,000
2,300,000
2,400,000
2,500,000
2,600,000
2,700,000
2,800,000
2,900,000
3,000,000
3,100,000
3,200,000
3,300,000
3,400,000
3,500,000
3,600,000
3,700,000
Gas Power Burner
With Barometric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
6
100
6
100
6
100
8
100
8
100
8
100
8
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
100
12
98
12
PAI-3
PAI-3*
1.26
Amps
115v
PAI-7*
BTU/HR
Input
Motor
Amps
Gas
Atmospheric
Max Duct
Rigid Duct
Length in
Diameter
Equiv. Feet
In Inches
100
6
100
6
100
6
100
8
100
8
100
8
100
8
52
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
100
10
95
10
100
12
100
12
100
12
100
12
100
12
100
12
100
12
98
12
Direct Drive Centrifugal Fans
FOR GENERAL VENTILATION SYSTEMS
INCLUDING RANGE HOOD EXHAUST
All fans by Fantech utilize unique external rotor motors. The motors totally enclosed design allows the fan to operate
in high moisture, lint and dust laden air. The motors are permanent split capacitor with automatic reset thermal overload protection and sealed ball bearings. All motors and impellers are designed as one integral unit for excellent motor
heat dissipation, even at a low RPM. Air stream temperature to 140°F and 100% speed controllable.
RVF Series Wall Mount
•
•
•
•
Simple to install no extras are needed
Galvanized steel housing with Baked Enamel finish
Housing removable for easy access to motor and wiring
Variable speed controllable
RPM
RVF4XL
2700
RVF6XL
3000
RVF8XL
2900
1.42
®
CFM @ S.P. (inches of H2O)
120V 1Ø
Amps
Model
UL
.1
.2
.4
.6
.84
180
172
154
136
118
1.46
360
346
315
285
258
410
392
348
312
282
235
Speed Control Model No. C64
.8
1.0
Ship
Wt. Lbs.
1.2
1.4
91
57
28
213
164
92
14
180
128
16
10
(See below for dampers.)
Dimensions In.
Model
a
b
c
d
e
RVF4XL
101⁄4
13
6
11⁄4
4
RVF6XL
141⁄4
17
6
11⁄2
6
RVF8XL
141⁄4
17
6
11⁄2
8
RE Series Roof or Wall Mount
•
•
•
•
DAMPERS
Spring Loaded Butterfly
Dia. (in.)
4
6
UL
®
Suitable for pitched roof or wall mounting
Galvanized steel housing with Baked Powder Coat finish
Cover easily removable for access to motor and wiring
Variable speed controllable
Model
RPM
120v 1Ø
Amps
0
RE6
RE8XL
RE10XL
2696
2830
3250
.80
1.48
3.61
227
409
753
1
⁄4
199
362
721
CFM @ S.P. (Inches of H2O)
3
1
3
⁄8
⁄2
⁄4
1
11⁄2
184
331
705
51
130
548
169
307
690
134
259
656
106
212
622
13⁄4
Ship
Wt. Lbs
508
15
15
20
Speed Control Model No. C64
Model
RSK4
RSK6
8
10
12
RSK8
RSK10
RSK12
14
16
RSK14
RSK16
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Dimensions In.
CATALOG #37
www.centralfan.com
Model
a
c
d
RE6
133⁄16
b
61⁄2
151⁄2
6
RE8XL
153⁄4
6
20
8
RE10XL
193⁄4
113⁄4
20
10
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
15
FG Series In-Line Mount
FOR GENERAL VENTILATION APPLICATIONS
• Galvanized steel housing
• Mounting bracket included for ease of installation
UL
• External wiring box for ease of connection
®
• Auto thermal
120V 1Ø
AMPS
.73
CFM @ S.P. (Inches of H2O)
0
148
1
1
3
1
3
139
130
120
111
90
⁄8
⁄4
⁄8
⁄2
⁄4
11⁄4
42
Ship
Wt. Lbs.
8
Duct
4"
RPM
2800
FG5XL
5"
2650
.76
191
175
161
146
131
102
75
45
–
8
FG6XL
6"
2950
1.26
392
368
346
326
305
263
228
191
150
11
FG8XL
1.
68
11⁄2
–
Model
FG4XL
8"
2950
1.31
521
496
469
440
411
345
282
231
180
12
FG10XL
10"
3000
2.11
590
565
541
519
496
442
394
339
290
14
FG12XL
12"
3250
3.21
801
783
765
747
729
692
655
611
566
21
Dimensions In.
d
D
FG4XL
7
a
1
1
4
93⁄4
FG5XL
6
1
1
5
93⁄4
FG6XL
65⁄8
1
1
6
131⁄8
8
133⁄8
10
133⁄8
12
16
Model
FG8XL
b
c
1
1
1 ⁄8
1
1
1 ⁄8
6
FG10XL
7
5 ⁄8
1 ⁄8
FG12XL
1
1
8 ⁄4
1 ⁄16
3
1 ⁄16
FR Series In-Line Mount
FOR HOSTILE ENVIRONMENT VENTILATION
•
•
•
•
•
DB 10 DRYER
BOOSTER SWITCH
U
L
Housing manufactured of thermoplastic resin
UL listed for outdoor use or wet locations
Waterproof gasket on wiring box
Mounting bracket included
Auto thermal
DO NOT USE IN COMBUSTIBLE ATMOSPHERE
Allows FR110 or RVF4 to be used as
booster fan for residential clothes dryers. The automatic pressure switch
turns fan off and on in 10 minute
cycles only when dryer is running.
Allows fans to be used on runs up to
80' and 6 elbows of 4" rigid duct.
(120v only)
®
CFM @ S.P. (Inches of H2O)
120V 1Ø
amps
0
.2
.4
.6
.8
1.0
Ship
Wt. Lbs
Model
Duct
RPM
1.5
FR110
4"
2900
.72
167
150
133
113
88
63
–
7
FR140
6"
2850
.53
214
190
162
132
99
46
–
7
FR160
6"
2750
1.14
289
260
233
206
179
154
89
8
FR225
8"
3100
1.35
429
400
366
332
297
260
168
11
FR250
10"
2850
2.04
649
600
553
506
454
403
294
13
Dimensions In.
PB100 BATH FAN
100 CFM fan, ceiling grille and grille
housing with damper. Uses 4" duct.
PB190 PREMIUM BATH FAN
190 CFM fan, ceiling grille and grille
housing with damper. Uses 6" duct.
Home Ventilating Institute guidelines
recommend one CFM per square foot
for bathrooms 100 ft2 and under. Over
100 ft2 use 50 CFM/fixture,
i.e., 1 toilet, 1 shower, 1 tub = 150 CFM.
Model
a
FR110
51⁄4
FR140
7
5 ⁄8
FR160
3
6 ⁄8
1
FR225
61⁄4
11⁄2
FR250
1
6 ⁄4
b
c
7
⁄8
1
–
7
⁄8
7
⁄8
7
⁄8
1
1 ⁄2
11⁄2
d1
d2
37⁄8
47⁄8
7
5 ⁄8
1
6 ⁄4
113⁄4
7
5 ⁄8
1
6 ⁄4
113⁄4
77⁄8
97⁄8
131⁄4
–
7
131⁄4
9 ⁄8
Speed Control
Mounting Clamps
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
91⁄2
Accessories:
4"
5"
6"
8"
10"
12"
C64
C64
C64
C64
C64
C64
Backdraft Damper RSK4 RSK5 RSK6 RSK8 RSK10
16
D
CATALOG #37
www.centralfan.com
FC4
FC5
FC6
FC8
FC10
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
RSK12
FC12
FKD Series In-Line Centrifugal Fans
•
•
•
•
•
•
•
Backward curve mixed flow fan impeller
100% Speed controllable ball bearing 115V motor with overload protection
Galvanized heavy gauge housing with baked powdercoat finish
Inlet and outlet slip type duct connections
Capable of operation in air stream temperatures up to 140°F
Terminal box prewired
UL approved
CFM @ S.P. (INCHES H2O)
Model
NEW
FKD 8XL
FKD 10XL
FKD 12XL
FKD 14XL
FKD 16XL
FKD 18XL
RPM
2700
2850
1700
1550
1600
1700
120V
Amps+
Sones*
2.99
4.84
4.80
7.12
12.40
3.75**
14.1
21.0
18.7
19.9
25.0
32.0
1/4
3/8
761
1187
1832
2416
4014
5995
720
1147
1746
2303
3880
5874
1/2
680
1100
1649
2180
3743
5754
11⁄4
1
3/4
595
1006
1423
1936
3452
5500
499
911
1066
1662
3137
5199
393
810
606
1294
2794
4909
11⁄2
2
286
696
460
843
2379
4602
1242
3703
Ship
Wt.
Lbs
16
22
46
52
84
95
*The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA Standard 301. Values shown are for installation
Type A: free inlet fan sone levels @ 1⁄2" W.G. Dampers see pg. 15.
**FKD18XL 230/460V 3PH (amps shown are for 460V)
FKD 8XL-10XL
FKD 12XL-14XL-16XL-18XL
Dimensions (inches)
Model
FKD8XL
FKD10XL
FKD12XL
FKD14XL
FKD16XL
NEW FKD18XL
A
8
10
12
14
16
18
A1
12
14
16
18
A2
14
16
18
20
C
121⁄2
14
177⁄8
193⁄4
221⁄8
221⁄4
D
151⁄2
15
187⁄8
201⁄4
231⁄4
291⁄4
E
7
8
F
15⁄8
15⁄8
15⁄8
13⁄4
⁄
78
11⁄2
11⁄4
2
FSD Series In-Line Centrifugal Fans
•
Backward curve mixed flow fan impeller
•
100% Speed controllable ball bearing 115V motor with overload protection
•
Galvanized heavy gauge housing with baked powdercoat finish
•
Inlet and outlet “ductmate” type duct connections
•
Capable of operation in air stream temperatures up to 140°F
•
Terminal box prewired
•
UL approved
CFM @ S.P. (INCHES H2O)
Model
RPM
120V
Amps+
FSD 18
FSD 20
FSD 22
FSD 26
1700
1600
1600
1700
4.80
6.36
15.00
3.82**
Sones*
1
12.4
14.1
21.0
27.0
2237
2921
4918
6644
⁄4
3
1
3
⁄4
1
1 ⁄4
1 ⁄2
2126
2766
4766
6473
1987
2605
4605
6317
1644
2241
4282
5981
1180
1829
3865
5608
658
1341
3337
5177
815
2716
3469
⁄8
⁄2
1
2
Ship
Wt.
Lbs
1308
1937
62
77
115
134
1
+Amperages are maximum for the given RPM. **FSD26 230/460V/3ø Amps shown are for 460V.
*The sound ratings shown are loudness values in fan sones at 5 ft. in hemispherical free field calculated per AMCA
Standard 301. Values shown are for installation Type A: free inlet fan sone levels @ 1⁄2" W.G. FSD26 is @3⁄4" W.G.
Side View
Inlet View
Speed Controls
Dimensions (inches)
Model
A sq.
C sq.
Model
FSD18
175⁄8
153⁄4
C64
6
FSD 20
193⁄4
173⁄4
10
FSD 22
211⁄2
C65
19
15
26
201⁄4
C66
FSD 26
7
Note: Flanges extend ⁄8" beyond
the “A” dimension
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
Max. Amps
Additional Accessories:
Backdraft Dampers Pg. 8
Vibration Isolators Pg. 39
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
17
BATHROOM FANS
ut
Abo
s
Ask iscount
ity D
t
n
a
Qu
UL
®
AMCA CERTIFIED
688
671, 676, 684
HD50, HD80
679
655
CEILING OR WALL MOUNTING - With backdraft damper - Plastic grille
Control†
CFM
Noise
Level
Sones
688*
671*
684*
676*
C64
C64
C64
C64
50
70
80
110
4.0
6.0
2.5
4.0
3
3
4
4
45
65
75
100
.9
1.15
.5
1.3
71⁄2
71⁄2
81⁄4
81⁄4
71⁄4
71⁄4
8
8
35⁄8
35⁄8
53⁄4
53⁄4
91⁄4
91⁄4
111⁄8
111⁄8
9
9
105⁄8
105⁄8
5
5
8
8
Commercial Duty
continuous operation
HD 50*
HD 80*
C64
C64
50
80
1.5
2.5
4
4
45
75
.4
.5
81⁄4
81⁄4
8
8
53⁄4
53⁄4
101⁄4 x 101⁄4
101⁄4 x 101⁄4
7
7
Fan with Light (100 watt)
Fan with Light & Heat (1300w.)
679*
655
#68
#66
70
70
3.5
4.0
4
4
65
65
2.
12.8
81⁄4
14
8
81⁄4
53⁄4
53⁄4
111⁄8 x 95⁄8
153⁄4 x 105⁄8
8
14
All 115V. AC
Type
Bathroom fans
Model
Economy
Deluxe
Premium
Premium
Model 655 has separate blower for heater.
†Optional model MHR control (see p.19)
Round
For
Outlet Area
Inches Sq. Ft.
*U.L. listed for use in tub/shower enclosure with GFCI wiring.
QTR80, QTR110
QTXE150
Amp
Housing Size
L
W
H
Grille
Size
x
x
x
x
Ship
Wt.
Lbs.
Metal grille for 671, 676, 684, 688 available.
QTR110L
162, 164
750
Model
Control**
CFM
Noise
Level
Sones
Fan Only
Fan Only
Fan Only
Fan w/Light/Nite Light
QTR80*
QTR110*
QTXE150*
QTR110L*
C64
C64
C64
#67
80
110
150
110
1.0
1.5
1.4
1.5
4
4
6
4
75
100
140
100
Fan w/Light/Nite Light
750*
#67
100
3.5
4
95
1.9
9
9
9
15 Rd.
12
Fan & 250 w. Infrared bulb (I bulb)
(2) 250w. Infrared bulbs (2 bulbs)
162†
164†
#68
#68
70
70
3.0
3.0
4
4
65
65
3.5
5.5
121⁄2
181⁄2
111⁄2
12
53⁄4
61⁄2
101⁄2 x 10
101⁄2 x 16
8
10
All 115V. AC
Type
*U.L. listed for use in tub/shower enclosure with GFCI branch wiring.
Round
Outlet
Inches
For
Area
Sq. Ft. Amp
**Optional model MHR control (see page 19)
.7
.9
.5
1.8
Housing Size
L
W
H
1
11 ⁄4
3
5
10 ⁄8
7 ⁄8
Grille
Size
13 x 14
13 x 14
14 x 15
123⁄8 x 14
Ship
Wt.
Lbs.
12.4
12.4
13.2
13.8
†R40 Infrared bulbs not included.
Broan Kitchen & Bathroom Fans
L300KMG
502, 503
All 115V. AC
Type
Wall or
Ceiling
Mount
Ceiling
Mount only
(No dampers)
673
Model
CFM
Noise
Level
Sones
Outlet
Size
Inches
Fan
Size
Dia.
503
502
L300KMG*
160
270
286
5.5
7.0
2.8
31⁄4 x 10
31⁄4 x 10
8
8
10
Blower
Amp.
1.7
1.7
2.7
673
505
504
60
180
350
4.0
4.5
6.5
61⁄4
81⁄4
101⁄4
6
8
10
1.0
1.5
1.7
504, 505
Housing Size
L
W
14
163⁄4
121⁄4
12
137⁄8
121⁄4
61⁄4 dia. X 55⁄16
81⁄4 dia. X 7
101⁄4 dia. X 7
H
White Polymer
Grille
Size†
Ship
Wt.
Lbs.
31⁄4
31⁄4
113⁄4
111⁄2 sq.
131⁄2 sq.
14 x 14
10
12
25
8 dia.
111⁄4 sq.
131⁄2 sq.
4
8
10
No. C64 variable speed control for all fans shown above.
No. 472 damper with reducer to 8" for Model 504
†Metal grille for models 502, 503, 504, 505 available.
*Suitable for use above cooking surface. Motor is thermally protected for higher temp., galv. steel impeller, metal grille. Dishwasher safe aluminum mesh filter LAFI (12" x 12" p. 19)
18
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
BROAN WALL FANS
With backdraft dampers - Unbreakable white polymer grilles (paintable)**
CFM
Noise
Level
Sones
RPM
Amp.
For Wall
Thickness
Exterior weatherhood
509
508
C64
C64
180
270
5.0
6.0
8
10
1500
1500
1.5
1.7
41⁄2 to 91⁄2
41⁄2 to 91⁄2
9"
11"
111⁄4
131⁄2
11
16
Chain-operated w/outside
door
507
506
C64
C64
250
480
5.0
6.5
8
10
1500
1500
1.5
1.7
41⁄2 to 91⁄2
41⁄2 to 91⁄2
9"
11"
111⁄4
131⁄2
11
13
Motor-door
12C
C64-3
380
4.5
10
1500
1.7
5 to 10
12" Sq.
131⁄2
20
12" Sq.
12" Sq.
131⁄2
131⁄2
8
9
All 115V AC
Type
Model
Room to room thru wall
511
510
Control*
(on fan)
(on fan)
**Optional metal grille available for 12C, 506, 507, 508, 509
180
380
Blade
Dia.
3.5
5.5
8
10
1500
1500
1
3 to 5 ⁄2
3 to 51⁄2
1.5
1.7
Hole
Required
Dia.
Grille
Size
Sq.
Ship
Wt.
Lb.
*Optional model MHR control (see below) electronic delay switch.
ACCESSORIES
WALL CAP
Spring Loaded Damper
Black Enamel Finish
Model 639
Flat roof installation
Aluminum – natural finish
Built-in screen
Curb mount installation
Aluminum – natural finish
Built-in screen
Model 611
Model 611CM
SHORT EAVE ELBOW
Damper & Grille
Black Enamel Finish
Model 430
3" or 4" WALL CAP
Damper
Aluminum
Model 642
TRANSITIONS
Duct Transition
Model
31⁄4" x 10" to 6"
31⁄4" x 10" to 7"
31⁄4" x 10" to 8"
411
412
413
ROOF CAP
Damper & Bird Screen
Black Enamel Finish
Model 634
Model 644 (Alum.)
6", 7" or 8" WALL CAP
Damper & Bird Screen
Aluminum
Model 641 (6")
Model 643 (8")
(No screen)
ROOF CAP
3" or 4" Duct
Damper & Bird Screen
Black Enamel Finish
Model 636
SWITCHES
Washable Filters
Model
8" OØ Aluminum (fits 505 & 509)
10" OØ Aluminum (fits 12C, 504, 508, 510 & 511)
LAF1 12" x 12" (fits L300KMG)
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
LONG EAVE ELBOW
Damper & Grille
Black Enamel Finish
Model 431
Model
Timers
C71-5
C71-15
C71-60
C72
5 min.
15 min.
60 min.
12 hr. (+ hold)
Control
Model
C64
C64-3
66
68
67
Vari-speedFor Model 12C
For Model 655
For Model 679, 162, 164
For QTR110L, 750
Model MHR: Electronic Fan-Light-Time Delay Control
120v 7.5 amp (fans) 120v 10.0 amp (heaters) 500 w. (lamps)
Adjustable timer allows fan operation after light switched off.
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
19
L100
L150
L200
L250
L300
LOWEST SOUND LEVELS IN THE INDUSTRY
•
•
•
•
•
•
•
•
•
L400
L500
L700
L900
L1500
Attractive white grille blends with any decor.
Specially designed resilient motor mount helps eliminate vibration
Low RPM motors are permanently lubricated and thermally protected.
Rugged 20 ga. steel housing with 1⁄2" acoustic insulation.
Automatic backdraft damper located within duct connector.
8 position adjustable mounting brackets permit installation flexibility.
Available in ceiling or in-line models.
Air volume may be varied with speed control.
Available in 240 vac and 277 vac (Special order).
CFM*
static press. (in water)
Ceiling
Model
In-Line
Model
0
L100
L150
L100L
L150L
L200
L250
L300
Motor
Max.
120v
RPM Amps
®
Wt.
Lbs.
⁄4
65
124
12
94
.8
1.4
640
710
1.1
1.3
6 Dia.
121⁄4
121⁄4
113⁄4
14 x 14 (P)**
23
186
242
296
177
233
287
144
201
254
1.8
2.3
2.9
740
830
905
1.8
2.1
2.6
8 Dia.
121⁄4
121⁄4
113⁄4
14 x 14 (P)**
23
344
463
640
299
434
607
182
339
534
2.4
3.1
4.6
735
810
960
1.4
2.2
2.9
41⁄2 x 181⁄2
211⁄2
121⁄4
113⁄4
231⁄4 x 14 (S)
34
877 842
1438 1371
793
1285
636
1103
4.0
8.4
650
955
3.0
5.0
8 x 12
22
18
18
237⁄8 x 197⁄8 (S)
64
⁄4
3
1
136
181
93
141
80
132
L200L
L250L
L300L
231
272
312
196
250
303
L400
L500
L700
L400L
L500L
L700L
480
538
722
388
491
667
L900
L1500
L900L
L1500L
918
1578
⁄8
3
⁄2
Housing (In.)
L
W
H
Grille
Molded Plastic (P)
Enameled Steel (S)
Sones
@ 1⁄10"
1
Outlet
Size (in.)
UL
*CFM is reduced slightly on in-line models
**Metal Grille L100-L300 Available at extra charge
High Volume Cabinet Ventilators
•
•
•
•
•
•
Designed for continuous operation.
May be installed in ceiling or wall.
Shipped in horizontal discharge - convertible to vertical discharge.
May be converted to ceiling fan with grille kit.
Air volume may be varied with speed control. (see below)
L2000 is 115v; L3500EXL is 230v 1Ø
L2000L
L3500EXL
(shown with optional
grille and damper kit)
CFM
static press. (in water)
1
1
⁄4
3
⁄8
1
3
Model
L2000L
0
⁄8
1891 1791
⁄2
⁄4
1657
1508
1347
808
1.0
–
L3500EXL
3608 3452
3278
3073
2893
2429
1693
UL
®
Motor
Sones
@ 1⁄10"
9.8
RPM
965
Volts
115
Amps
5.8
Wt.
Lbs.
89
14.8
1105
230
5.4
144
DIMENSIONS
Inlet
Outlet
Outside Dimensions
Model
A
B
C
D
H
W
L2000L
123⁄8
353⁄4
333⁄4
73⁄4
145⁄8
145⁄8
L3500EXL
1
14 ⁄2
1
43 ⁄2
3
41 ⁄8
3
9 ⁄4
3
16 ⁄4
3
16 ⁄4
L
38
3
45 ⁄4
Mounting Hole Spacing
E
73⁄4
1
10 ⁄4
Grille
F
G
N
Width
Length
333⁄4
125⁄8
395⁄8
161⁄4
395⁄8
3
41 ⁄4
5
12 ⁄8
3
47 ⁄8
3
18 ⁄8
471⁄4
ACCESSORIES
Speed Controls
C64 (L100-L900)
C65 (L1500-L2000L)
C75 (L3500EXL) 230V
Duct Transition
423 - 4 ⁄2" x 18" to 10" (L400-500-700)
T81212 - 8" x 12" to 12" (L900-1500)
1
20
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Wall Caps
641 - 6"
643 - 8"
613 - 12"
Roof Jacks
634 - 8"
437 - 12"
Damper Kit
D100 (L2000)
D101 (L3500EXL)
Grille Kit
G102 (L2000L)
G103 (L3500EXL)
CATALOG #37
www.centralfan.com
Radiation Dampers
RD1 L100-L300
RD2 L400-L700
RD3 L900 & L1500
Brick vent
BV8 - 73⁄4" x 81⁄8" x 4"
BV12 - 73⁄4" x 12" x 4"
BV16 - 73⁄4" x 155⁄8" x 4"
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
The T-Series range boasts features and a
specification that marks a radical departure
from current unit ventilation technology.
• Designer-styled
in two-tone grey to bring
slim sophisticated good looks to today's
commercial and residential environments.
• A Speed Control Pack which gives one of
three fixed speeds at the time of installation
without the need for a Controller. When set
on High, T-Series fans give a performance
which outclasses competitive products.
• Four sizes in each model, mean 12 performance options - so sizing is no longer a hit or
miss affair.
• An
advanced interlocking shutter system
effectively closing against backdraft — controlled by state-of-the-art electronics to
ensure quiet and reliable actuation whatever
the angle of installation. (exhaust or supply)
• A new system of mounting for Window
and
Roof models which accommodates varying
mounting thicknesses. Wall models have telescopic liners for all types of walls and a neat
decorative trim.
• For
cleaning, T-series units can be completely dismantled in minutes without the
need for special tools and all the non-electrical components can be washed thoroughly
in warm soapy water.
WINDOW MODEL
TX Model—with electronically controlled integral shutter
Technical Data
WINDOW
MODEL
TX6WW
Mounting Exhaust Performance
Impeller Hole øO
Guide (cfm)
O (in)
ø
(in)
Low Medium High
71⁄4
6
1
55
2.7
TX6WL
6
111⁄4 x 113⁄8
158
205
233
55
196
257
313
60
1.9
60
1.9
TX7WL
7 ⁄2 127⁄8 x 13
9
101⁄4
275
403
467
95
2.8
TX9WL
9
143⁄8 x 143⁄4
302
443
513
95
2.8
12
131⁄4
645
833
950
130
4.1
TX12WL
12
173⁄8 x 173⁄4
697
900
1027
130
4.1
Mounting Exhaust Performance
Impeller Hole ø
Guide (cfm)
O
ø
(in)
O (in)
Low Medium High
6
1
TX7RF
7 ⁄2
TX9RF
9
12
71⁄4
55
2.7
91⁄8 x 95⁄8
174
225
257
55
2.7
284
60
1.9
TX7PL
7 ⁄2 105⁄8 x 111⁄8
216
282
344
60
1.9
101⁄4
275
403
467
95
2.8
TX9PL
9
121⁄8 x 127⁄8
333
488
565
95
2.8
593
767
873
130
4.1
TX12PL
12
151⁄4 x 153⁄4
748
967
1108
130
4.1
TX6PL
6
Exhaust Performance
Guide (cfm)
Watts Sones
Low Medium High (Med) (Med)
233
13 ⁄4
172
Impeller Mounting
øO (in) Hole (in)
178
1
147
PANEL
MODEL
8 ⁄4
3
116
Watts Sones
(Med) (Med)
1
2.7
284
TX12WW
TX12RF
210
Exhaust Performance
Guide (cfm)
Watts Sones
Low Medium High (Med) (Med)
233
TX9WW
TX6RF
184
Impeller Mounting
øO (in) Hole (in)
178
7 ⁄2
ROOF
MODEL
145
WALL
MODEL
8 ⁄4
TX7WW
3
Watts Sones
(Med) (Med)
1
Darkroom Model: Exhaust or supply air ventilation without light intrusion . . .
automatic integral shutter. Darkroom model dimensions are similar to roof
model . . . except for the additional (interior) cowl. (derate 25%)
OPTIONAL CONTROLS (All models)
LIGHT-TIGHT GRILLE: black finish
Model LT 12 x 12
12" sq.
Model TFC 3 speed flush mntg. with reversing feature
Model LT 12 x 18
Model TSAT thermostat (41°-86°F)
12" x 18"
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Model TSC 3 speed surface mntg. with reversing feature
Model HSTAT humidistat (45%-90% RH)
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
21
IN-LINE CENTRIFUGAL
Direct drive or belt drive available
Galvanized steel construction
Aluminum airfoil impeller—non-overloading
Bearing assembly L-10 life of 200,000 hours
Operation to 200°F on belt drive applications; 140°F direct drive
Versatile . . . mounts in any position . . . square in/out
Easy access to all parts without disconnection of duct
AMCA B Spark resistant construction standard
NOT FOR GREASE EXHAUST
DIRECT DRIVE
SEE PP. 17, 23, 24, 25 FOR OTHER IN-LINE FANS
Model
No.
XD100
XD120 B
C
HP
1
⁄10
1
⁄8
⁄3
1
Single Phase
Three Phase
1 Speed 2 Speed 1 Speed 2 Speed
S
M
T
R
X
X
X
X(V)
X(V)
X
–
–
X
–
–
–
Accessories
@ 1⁄4"
Sones
Vib. Isol.
Vib. Isol.
Fan
RPM
0
3.0
7.5
10.0
1050
1300
‡1550
460
570
680
4.4
7.5
14.0
955
‡1140
1750
890
1068
1635
1
1
3
350
480
610
380
530
230
430
805
995
1590
650
910
1540
730
1490
⁄8
‡Maximum RPM shown with the standard one speed motor. For all lower RPMs add solid state speed controller.
Model
No.
A
XB9 B
C
D
BELT DRIVE
B
XB120 C
D
E
C
D
XB137 E
F
G
D
E
XB161 F
G
H
11.7
14.0
16.7
21.0
1878
2274
2524
2933
675
875
990
1100
525
700
875
1000
325
600
750
975
–
–
X
X
Supp. Brkt. w/Isol.
Drive Cover
Chemical
Resist. Coat
13
15
18
21
1570
1725
2060
2335
1360
1515
1845
2110
1235
1410
1760
2040
930
1250
1670
1965
X
X
X
X
X
–
X
X
X
X
Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating
12
14
18
21
26
1365
1605
1830
2060
2310
1790
2195
2560
2920
3310
1490
1945
2360
2755
3170
1275
1705
2120
2555
3010
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating
12
14
17
20
24
1210
1365
1570
1710
1865
2710
3095
3600
3940
4320
2485
2930
3470
3825
4215
2165
2680
3300
3690
4100
2375
3070
3510
3960
X
X
–
–
–
X
X
X
X
X
–
X
X
X
X
Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating
13
14
18
23
27
985
1055
1250
1410
1525
4285
4590
5560
6350
6910
3830
4215
5250
6080
6660
3375
3815
4930
5800
6400
1890
3160
4590
5510
6140
R
Accessories
1
X
X
X
X
–
X
X
–
–
X
X
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
1
11⁄2
1
⁄2
3
⁄4
1
1
1 ⁄2
2
3
⁄4
V=control included
Supp. Brkt. w/Isol.
Drive Cover
Chemical
Resist. Coat
T
1
⁄4
⁄2
3
⁄4
E
F
XB200 G
H
J
1
1
1 ⁄2
2
3
X
X
X
X
X
F
G
XB245
H
J
K
1
1
1 ⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating
12
16
19
25
34
735
855
965
1100
1295
6210
7375
8425
9700
11530
5675
6940
8045
9370
11250
4130
6435
7645
9055
10970
G
H
XB300
J
K
L
11⁄2
2
3
5
71⁄2
X
X
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
Supp.Brkt. w/Isol.
Drive Cover
Chemical
Resistant
Coating
13
16
20
23
30
595
670
775
875
1010
8340
9610
11340
12960
15125
7255
8720
10690
12370
14625
5560
7665
9800
11700
14090
*Single phase 120v or 230v. (X) Available models
See p. 10 for 208v, other special motors and controls.
Disconnect switches (p. 43)
1
3
⁄2
⁄4
1
37
290
105
1450
1290
860
(X) Available models
1
11⁄2
180
450
625
875
150
450
675
21⁄2
2
O.V. = 1.0 CFM
150
500
260
O.V. = .571 CFM
760
1545
1880
740
1580
720
680
O.V. = .421 CFM
1530
1930
2350
2825
5060
7160
8680
10860
1500
2045
2485
2160
3055
3580
3155
4885
5590
7600
10070
1350
2240
1550
5870
9080
12150
22
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Model
(Direct)
XD100
XD120
A
14
177⁄8
B
189⁄16
247⁄8
Model
(Belt)
XB9
XB120
XB137
XB161
XB200
XB245
XB300
XB365
A
14
177⁄8
201⁄2
241⁄4
30
363⁄4
45
543⁄4
B
181⁄2
247⁄8
281⁄8
3211⁄16
393⁄4
481⁄16
585⁄16
711⁄16
48
64
100
130
155
170
220
1445
3030
230
1155
O.V. = .184 CFM
300
3030
4870
330
2305
O.V. = .119 CFM
400
9180
450
5613
O.V. = .082 CFM
5570
8880
10925
13500
Ship
Wt.
O.V. = .291 CFM
10470
5665
600
720
Backdraft dampers, see p. 8.
DIMENSIONS
MODEL XB
Ship
Wt.
O.V. =.571 CFM
1
M
⁄6
⁄4
⁄3
1
⁄2
1
⁄14
⁄3
1
⁄2
3
⁄4
1
⁄13
⁄2
3
⁄4
⁄8
Fan
RPM
S*
1
⁄4
@ ⁄2"
Sones
HP
1
1
Approx. CFM
Static Pressure (inches of water)
Impeller
Size
97⁄8
1115⁄16
C
Max
12
113⁄16
113⁄16
1311⁄16
1311⁄16
1311⁄16
163⁄8
163⁄8
D
Max
14
151⁄4
151⁄4
181⁄2
181⁄2
181⁄2
20
20
MODEL XD
Impeller
Size
103⁄16
1115⁄16
1311⁄16
1
16 ⁄8
20
241⁄2
30
361⁄2
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Duct Blower and Duct Filter
All-purpose indoor cabinet blower with optional compact filter.
• Install in any position-ball bearing blower
• Insulated cabinet for quiet operation
• Drawer type filter rack for easy maintenance
• Access panels on both sides
DUCT
BLOWER
Model
No.
207
209
210
A
B
C
D
E
O.V.
FPM
759
1139
1519
1899
2409
RPM
567
822
975
1073
1469
BHP
.02
.07
.14
.21
.43
RPM
737
822
975
1149
1414
BHP
.04
.05
.14
.24
.48
RPM
1019
1051
1134
1272
1526
X
X
X
X
800
1000
1200
1400
1600
951
1189
1427
1665
1902
468
534
613
696
782
.06
.09
.15
.23
.34
581
625
682
750
828
.07
.12
.18
.26
.37
786
802
834
881
936
.12
.17
.24
.33
.44
974
964
979
1009
1050
.19
.23
.30
.40
.52
1130
1118
1115
1132
1162
.26
.31
.38
.48
.60
1379
1384
1371
1362
X
X
X
X
1000
1200
1400
1600
1800
964
1157
1350
1543
1736
422
470
525
582
642
.06
.10
.15
.22
.29
531
559
593
640
693
.09
.13
.18
.25
.33
713
728
749
770
807
.15
.20
.26
.33
.41
869
873
886
905
928
.23
.28
.34
.42
.51
998
1005
1009
1021
1040
.31
.40
.43
.52
.62
X
X
X
X
X
1600
2000
2400
2800
3200
3400
1097
1371
1646
1920
2194
2331
423
489
562
640
721
762
.12
.21
.35
.53
.78
.92
974
1217
1461
1704
1948
2142
1297
1461
1621
1785
1945
2110
2270
2464
323
372
431
491
553
604
302
328
356
384
413
442
472
508
.15
.26
.42
.59
.94
1.23
.40
.55
.72
.94
1.19
1.50
1.83
2.31
.17
.26
.40
.59
.83
.98
.21
.33
.49
.72
1.02
1.32
.50
.66
.83
1.06
1.32
1.65
1.98
2.48
658
690
734
786
846
877
529
546
575
608
646
679
448
460
473
491
510
532
555
584
.26
.37
.53
.73
.99
1.14
.34
.46
.66
.91
1.22
1.51
.74
.92
1.11
1.35
1.61
1.94
2.28
2.81
786
809
840
882
932
959
631
650
667
693
725
753
526
538
551
563
575
592
611
635
.35
.49
.66
.88
1.16
1.32
.49
.64
.81
1.10
1.44
1.77
.97
1.18
1.41
1.68
1.95
2.45
2.66
3.18
905
915
941
973
1015
2000
2500
3000
3500
4000
4400
4000
4500
5000
5500
6000
6500
7000
7600
507
559
620
687
758
796
399
432
471
523
580
628
351
373
395
420
445
471
499
533
716
736
754
771
798
823
610
605
615
630
641
653
666
687
1
B
C
9209 D
E
⁄4
⁄3
1
⁄2
3
⁄4
1
1
B
C
9210 D
E
⁄4
⁄3
1
⁄2
3
⁄4
1
C
⁄3
D 1⁄2
212
3
⁄4
9212 E
F 1
1
G 1 ⁄2
E
F
215
9215 G
H
J
F
G
9218 H
J
K
OUTDOOR DUCT BLOWER WITH HOOD
AND WEATHER RESISTANT CABINET
Single
Speed†
1Ø 3Ø
HP S†† T CFM
1
X
–
400
⁄6
1
X
X
600
⁄4
1
X
X
800
⁄3
1
X
X
1000
⁄2
3
X
X
1300
⁄4
1
218
For outdoor installation use heavy duty,
weather resistant 9200 models.
FILTER
3
⁄4
1
11⁄2
2
3
1
11⁄2
2
3
5
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
X
X
X
X
X
1
1
⁄8"
1
⁄4"
ACCESSORIES:
Vibration hangers
Aluminum mesh filters
Intake hood (includes filter)
RPM
2020
2051
2038
2053
.41
.48
.56
.65
1578
1590
.56
.67
1210
1221
1229
.47
.55
.65
1387
.66
.47
.61
.79
1.03
1.35
1106
1108
1118
1142
.72
.88
1.08
1.35
1276
1279
1278
.99
1.19
1.40
1420
1.27
.63
.83
1.09
1.27
1.65
2.01
1.28
1.44
1.69
2.00
2.32
2.7
3.07
3.61
856
879
899
918
935
950
754
752
746
741
750
765
777
791
.96
1.19
1.48
1.80
2.14
2.44
1.93
2.10
2.39
2.65
3.00
3.45
3.91
4.53
971
998
1020
1039
1058
1.30
1.58
1.92
2.31
2.74
1071
1101
1125
1146
1.65
2.0
2.37
2.81
868
871
869
864
857
858
868
2.62
2.96
3.22
3.58
3.79
4.20
4.69
967
971
973
972
969
3.32
3.75
4.03
4.51
4.82
DUCT BLOWER
18
153⁄8
209
21
210
221⁄4
212
215
218
80
90
90
100
115
150
170
240
275
330
INTAKE HOOD
FILTER
**Incl. Filters.
Duct Blower Dimension
207
.72
– .
H09
H10
H12
H15
H18
*S.P. drop @ max. CFM shown above.
Model
80
1751
Intake Hood
Model**
.171
.124
.124
.241
.182
.241
Ht.
B
Ship
Wt.
Lbs.
70
SEE P. 45 FOR ROOF MOUNTED, SIDE INTAKE AIR SUPPLY UNITS
Aluminum Mesh Filter
Model
S.P.*
Width
A
21⁄2"
RPM BHP
2242
.42
2286
.58
2292
.71
2"
BHP
.37
.45
.58
.70
*Static pressure reduction on blowers designed for higher pressure could result in motor overload.
(X) Available models
† 2 speed 1Ø or 3Ø page 10
†† 1 phase 120v or 230v. See p. 10 for 208v 1Ø
F207
F209
F210
F212
F215
F218
Static Pressure (inches water)*
3
1"
11⁄2"
⁄4"
BHP RPM BHP RPM BHP RPM BHP
.07
1257
.11
1448
.15 1761
.24
.12
1255
.16
1437
.20 1777
.32
.18
1308
.24
1473
.30 1768
.41
.29
1400
.35
1540
.43 1809
.57
.67
1618
.62
1713
.69
⁄2"
Length
C
Filter Dimensions
Outlet
Inlet
D
E
F
G
H
J
K
23
81⁄4
93⁄16
141⁄2
95⁄8
11⁄4
11⁄4
7
18
23
101⁄4
1113⁄16
171⁄2
113⁄4
11⁄4
13⁄4
20
243⁄4
113⁄8
131⁄8
183⁄4
133⁄8
11⁄4
13⁄4
27
23
331⁄2
28
271⁄2
137⁄16
155⁄8
231⁄2
161⁄8
11⁄4
13⁄4
32
157⁄8
185⁄8
28
191⁄2
25⁄8
13⁄4
411⁄2
34
44
195⁄8
225⁄8
35
24
23⁄4
13⁄4
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
⁄8
7
⁄8
7
⁄8
7
⁄8
7
⁄8
11⁄8
CATALOG #37
www.centralfan.com
L
Inlet
M
Z
A
B
N
P
Filter Size
157⁄8
133⁄8
–
173⁄4
153⁄8
16
131⁄2
141⁄8 x 165⁄8
19
16
21
21
18
191⁄8
161⁄8
163⁄4 x 197⁄8
201⁄4
18
26
221⁄4
20
203⁄8
181⁄8
183⁄4 x 211⁄8
213⁄4 x 257⁄8
25
21
31
27
23
251⁄8
211⁄8
301⁄2
25
34
321⁄2
263⁄4
305⁄8
251⁄8
253⁄4 x 31
353⁄8
315⁄8
40
37
331⁄4
351⁄4
311⁄2
321⁄4 x 357⁄8
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
23
Tubemaster
BELT DRIVE
TUBEAXIAL FANS
•
•
•
•
•
Heavy duty all welded aluminum propeller
Permanently lubricated ball bearings
Maximum operating temperature to 200° F
Tough acrylic epoxy finish
Designed to operate in any position
Note: Axial fans running at relatively high tip speeds tend to be noisy.
Describe installation when ordering if fan noise is a potential problem.
Important: Duct must not be sharply reduced or turned near fan inlet
or discharge.
Model
No.
C
HA12 D
E
C
D
HA16 E
F
D
HA18 E
F
G
Approx. CFM
Static pressure (inches water)
Approx.
1 Phase* 3 Phase Fan
HP
S
T
RPM
1
⁄3
1
⁄2
3
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1
⁄2
⁄4
3
1
11⁄2
3
⁄4
0
1
⁄4
3
⁄8
1
3
⁄2
⁄4
X
X
X
X
X
X
2320
2680
3070
1970
2270
2600
1790
2120
2470
1670
2030
2400
1520
1930
2330
X
X
X
X
X
X
X
X
1976
2267
2600
2855
2994
3435
3940
4326
2613
3121
3666
4077
2353
2919
3525
3952
1929
2683
3337
3806
2871
3463
X
X
X
X
X
X
X
X
1730
1980
2180
2495
4060
4640
5120
5860
3660
4270
4800
5580
3440
4080
4640
5450
3160
3880
4450
5300
2000
3370
4050
4980
X
X
X
X
X
1250
1375
1570
1730
1980
6750
7450
8500
9350
10660
5950
6750
7900
8800
10220
5520
6360
7600
8520
9970
5000
5910
7250
8250
9720
4650
6450
7950
9200
E
F
HA24 G
H
J
1
11⁄2
2
3
X
X
X
X
X
F
G
HA30 H
J
K
1
11⁄2
2
3
5
X
X
X
X
–.
X
X
X
X
X
942
1078
1187
1358
1610
10000
11500
12600
14450
17120
8800
10450
11750
13700
16440
8050
9850
11250
13250
16070
7050
9100
10650
12800
15680
G
HA36 H
J
K
11⁄2
2
3
5
X
X
X
–
X
X
X
X
799
880
1007
1193
14550
16050
18350
21750
12900
14500
17000
20600
11900
13700
16300
20100
10400
12650
15500
19400
H
HA42 J
K
L
M
2
3
5
71⁄2
10
X
X
–
–
–
X
X
X
X
X
683
781
926
1060
1170
19650
22500
26650
30500
33550
17250
20400
25000
29100
32240
15750
19250
24000
28300
31520
13700
17900
23000
27600
30780
*1 phase 120v or 230v. See p.10 for 208v 1Ø
1
1660
2130
6700
9150
11700
14890
7800
11700
18100
13800
20750
25900
29260
Est.
Ship
Wt.
1870
49
51
54
2924
67
69
72
73
4600
74
77
78
88
7630
8600
114
115
125
134
151
10250
13980
229
239
248
265
279
10250
16450
284
293
310
324
17700
23800
27530
564
581
595
646
666
See Page 10 for
• Enclosed motors
• Exp. Proof motors
• Multi-speed motors
• Motor controls
ACCESSORIES
Size
HA12
HA16
HA18
HA24
ComAcc- Chem.
panion Drive Belt ess resist. Disc.
Flanges Cover Guard Door Coat* Sw.
X
X
X
X
X X
X
X
X
X
X X
X
X
X
X
X X
X
X
X
X
X X
HA30
HA36
HA42
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*See page 38 for coatings
(X) Available accessories
See page 10 for 2-speed motors. (X) Available models
DIMENSIONS (INCHES)
Model
A
B
C
D
F
HA12
14.69
12.00
13.44
12.19
17.00
HA16
18.75
16.50
17.50
16.06
19.00
HA18
21.13
16.50
19.88
18.44
20.50
HA24
27.00
18.00
25.75
24.38
24.00
HA30
33.75
24.00
32.25
30.50
29.00
HA36
39.75
29.00
38.25
36.50
32.00
HA42
45.75
32.00
44.25
42.50
37.00
Dimensions are shown in inches.
24
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CENTRIFAN®
BELT DRIVE
IN-LINE CENTRIFUGAL FAN
•
•
•
•
Backward curved wheel
Space saving in-line, tubular design
Floor, wall or ceiling installation
Vane straightened air flow (except C1050)
Suitable for Kitchen Hood Exhaust
C
D
E
C1050 F
G
H
1 Speed
S
H.P.
1
⁄3
⁄2
⁄4
1
3
1
11⁄2
2
1
⁄3
⁄2
⁄4
Bearings and drive out of airstream
All welded, rugged 10-16 ga. steel const.
Max. temp. 150°F
Arr. #9 Class 1
See Pages 16, 17, 22, 23, 24 For Other In-Line Fans
SINGLE PHASE*
Model
No.
•
•
•
•
THREE PHASE
2 Speed 1 Speed
M
T
Approx. CFM
2 Speed
R
1
1
⁄4
3
⁄2
RPM
O.Vel @
1
⁄4 S.P.
S.P.
S.P.
S.P.
1
S.P.
11⁄2
S.P.
2
S.P.
21⁄2
S.P.
3
S.P.
31⁄2
S.P.
4
S.P.
⁄4
X
X
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
–
–
–
–
–
–
2010
2310
2639
2904
3325
3660
920
1086
1260
1408
1624
1794
1000
1180
1370
1530
1765
1950
900
1100
1300
1460
1700
1900
790
1000
1220
1390
1640
1850
640
900
1140
1310
1580
1800
–m
605
950
1160
1450
1675
–m
–m
660
970
1315
1560
–m
–m
–m
640
1150
1425
–m
–m
–m
–m
935
1275
–m
–m
–m
–m
–m
1100
–m
–m
–m
–m
–m
800
X
X
X
X
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
–
X
X
X
X
–
–
1447
1657
1897
2088
2390
2630
3011
1000
1173
1367
1500
1740
1933
2250
1500
1760
2050
2250
2610
2900
3375
1360
1640
1950
2175
2550
2825
3275
1175
1510
1850
2090
2460
2750
3210
750
1335
1725
2000
2400
2700
3150
–m
–m
1375
1750
2200
2550
3025
–m
–m
–m
1275
1975
2350
2900
–m
–m
–m
–m
1625
2150
2750
–m
–m
–m
–m
–m
1700
2550
–m
–m
–m
–m
–m
–m
2325
–m
–m
–m
–m
–m
–m
2000
X
X
X
X
X
X
–
X
X
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1194
1367
1504
1722
1895
2170
2458
1040
1217
1361
1560
1726
1991
2257
2350
2750
3075
3525
3900
4500
5100
2150
2600
2950
3410
3800
4435
5015
1900
2400
2775
3300
3700
4325
4950
–m
2150
2600
3150
3600
4235
4890
–m
–m
1900
2800
3300
4025
4700
–
–
–
2100
2925
3800
4500
–m
–m
–m
–m
–m
3450
4300
–m
–m
–m
–m
–m
2950
4000
–m
–m
–m
–m
–m
–m
3675
–m
–m
–m
–m
–m
–m
3100
C
D
E
C1220 F
G
H
J
1
11⁄2
2
3
D
E
F
C1500 G
H
J
K
1
11⁄2
2
3
5
E
F
C1820 G
H
J
K
1
11⁄2
2
3
5
X
X
X
X
X
–
X
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
1010
1112
1273
1401
1603
1901
1017
1130
1325
1479
1717
2048
3375
3750
4400
4910
5700
6800
3100
3500
4150
4700
5500
6625
2775
3210
3950
4500
5300
6450
2000
2900
3700
4300
5100
6300
–m
–m
2900
3800
4725
6000
–m
–m
–m
–m
4300
5700
–m
–m
–m
–m
3200
5350
–m
–m
–m
–m
–m
4900
–m
–m
–m
–m
–m
3900
–m
–m
–m
–m
–m
–m
F
G
H
C2220
J
K
L
1
11⁄2
2
3
5
71⁄2
X
X
X
X
–
–
X
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
790
910
1000
1160
1370
1550
1000
1200
1350
1550
1850
2000
5100
5900
6700
7800
9200
10300
4800
5700
6400
7500
9000
10100
4100
5200
6000
7200
8700
10000
3400
4600
5600
6700
8500
9800
–m
–m
4480
6100
8000
9500
–
–
–
5000
7200
9100
–
–
–
–
6500
8500
–m
–m
–m
–m
5580
7900
–m
–m
–m
–m
–m
7100
–m
–m
–m
–m
–m
6100
G
H
C2450 J
K
L
M
11⁄2
2
3
5
71⁄2
10
X
X
X
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
–
780
850
980
1160
1330
1470
1120
1250
1480
1720
2000
2200
6700
7400
8800
10400
12000
13000
6300
7200
8400
9800
11800
13000
5600
6600
7850
9700
11300
12600
4800
6000
7600
9500
11000
12200
–m
–m
6500
8800
10500
12000
–m
–m
–m
7800
9800
11400
–m
–m
–m
6600
9300
10800
–m
–m
–m
–m
8400
10000
–m
–m
–m
–m
7200
9000
–m
–m
–m
–m
–m
8400
1
3
1
⁄2
⁄4
3
3
⁄4
*1 phase 120v or 230v. See page 10 for 208v 1Ø and other special motors.
Bare
Wt.
110
130
195
260
390
460
(X) Available models
Model
Pair
Comp.
Flanges
Belt
Guard
Floor
Legs
Access
Door
Chemical
Resist.
Coating
Weather
Cover
Spark Resist.
C1050
X
X
X
X
X
X
C1220
X
X
X
X
X
X
X
X
X
X
X
C1500
X
X
X
X
X
X
X
X
X
X
X
C1820
X
X
X
X
X
X
X
X
X
X
X
C2220
X
X
X
X
X
X
X
X
X
X
X
C2450
X
X
X
X
X
X
X
X
X
X
X
Ceiling
Vlb.
Brackets Isolators
X
X
B*
C*
Disc.
Switch
X
X
X
SEE PAGES 16, 17, 22, 23, 24
FOR OTHER CENTRIFUGAL
IN-LINE FANS
*See page 38 for description of spark resist. constr.
(X) Available accessories
Fan Dimensions
Size
A
C1050
14
1
C1220
16
9
C1500
C1820
C2220
C2450
⁄8
⁄16
5
20 ⁄16
11
24 ⁄16
5
30 ⁄16
1
33 ⁄4
B
C
1
16
5
18
⁄2
⁄8
5
26 ⁄8
3
32 ⁄8
1
39 ⁄2
5
43 ⁄8
18
21
D
E
1
16
9
18
⁄8
⁄16
5
22 ⁄16
11
26 ⁄16
3
32 ⁄4
3
35 ⁄4
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
F
23
H
2
2
9
1
⁄2
1
18 ⁄4
1
22 ⁄2
–
–
–
–
–
–
–
–
26
⁄8
1
31 ⁄8
7
36 ⁄8
1
24
30
18
39
33
19
3
⁄4
3
43
⁄4
L
14
21
⁄4
1
12 ⁄4
3
14 ⁄8
1
K
⁄8
1
29 ⁄8
7
34 ⁄8
1
10
1
J
9
⁄2
1
22 ⁄4
1
26 ⁄2
1
9
G
1
1
12
1
2
2
CATALOG #37
www.centralfan.com
⁄16
⁄16
9
⁄16
9
⁄16
9
⁄16
7
⁄8
M
P
Q
4
5
8
19
3
15
4
5
8
22
5
17
4
4
6
6
N
⁄16
⁄16
5
⁄16
5
⁄16
5
⁄16
3
⁄8
12
⁄4
⁄8
1
24 ⁄2
1
29 ⁄2
12
–
16
–
8
BC
Shaft
Dia.
1
1
9
1
⁄8
⁄16
5
21 ⁄16
11
25 ⁄16
9
31 ⁄16
1
34 ⁄2
1
3
⁄16
⁄16
7
1 ⁄16
1
3
1
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
25
RADIAL BLADE BLOWERS
DIRECT DRIVE - ARRANGEMENT 4
Recommended for small kitchen hoods where grease filters may or may not
be used-also for air containing dirt, dust, lint or other foreign material.
Wheels-Constructed with straight radial blades of heavy cast aluminum-Self
cleaning.
Dynamically balanced, Spark resistant. Suitable for 250°F. Max.
CLOCKWISE ROTATION-bottom horizontal discharge is furnished unless otherwise specified. Discharge position and rotation can be changed. Rotation is as
viewed from motor end. (See page 31.)
CW-BH Blower
ASSEMBLED AND TESTED-WITH BALL BEARING MOTOR
WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION & DISCHARGE
115/230V
CFM
Static pressure (inches water)
SINGLE PHASE THREE PHASE
Model
No.
KE
KE
KE
KE
KE
8
9
11
12
14
1 Spd. 2 Spd.
1 Spd. 2 Spd.
⁄8
S
M
T
R
RPM
0
1
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
–
–
X
X
X
1750
1750
1750
1750
1750
550
880
1430
2375
3420
⁄6
1
⁄4
1
⁄2
1
2
Special Motors: Multi-speed, enclosed, expl. prf - see page 10
*Single phase - 120v or 230v
For 208v 1Ø - see page 10.
1
1
HP
3
⁄4
510
825
1385
2300
3325
1
⁄8
470
765
1335
2220
3230
3
⁄2
425
705
1275
2140
3125
365
635
1225
2060
3025
⁄4
1
150
480
1100
1890
2820
200
945
1700
2595
11⁄4
11⁄2
730
1485
2350
Ship
Wt.
Lb.
2
430
1185
2045
35
40
60
120
150
350
1010
(X) Available models
ACCESSORIES
Blower
Model
KE
KE
KE
KE
KE
Vibration
Pads
Drive
Cover
Chemical
Resistant
Coating
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8
9
11
12
14
*Square…Model A14 shutter (p. 8.)
Shutter
to fit
Discharge
Disc.
Switch
X
X
X
X
X*
X
X
X
X
X
(X) Available accessories
Outlet Velocity (FPM) =
CFM
Area (Sq. Ft.)
Tip Speed (FPM)
At 1750 RPM = 458 x Dia. (in.)
Construction is of 16 gauge steel housings and bases—
Arc welded for rigidity.
Finish is Dark Gray epoxy.
Blower Dimensions
Model
No.
KE-8
Wheel
73⁄4 x 4
KE-9
9x5
KE-11
7
3
1
1
10 ⁄8 x 5 ⁄8
KE-12
12 ⁄2 x 7 ⁄2
KE-14
131⁄2 x 81⁄8
Bore*
1
⁄2
1
⁄2
5
⁄8
5
⁄8
7
⁄8
Certified Dimension Prints furnished upon request
OUTLET
A
11
1
12 ⁄8
3
14 ⁄4
3
B
C
D
E
8
81⁄4
53⁄8
5
8
3
1
9
1
10 ⁄4
3
11 ⁄4
1
6 ⁄2
8
5
16 ⁄8
10 ⁄2
13 ⁄4
9 ⁄8
175⁄8
101⁄2
145⁄8
103⁄4
5
5 ⁄8
F
7
7
7
1
6 ⁄8
7 ⁄2
3
3
7 ⁄8
8 ⁄4
8
83⁄4
INLET
G
H
J
K
L
M*
1
6
45⁄8
63⁄4
67⁄8
103⁄4
5
5 ⁄8
3
7 ⁄4
1
7 ⁄8
3
6 ⁄4
1
9 ⁄8
1
8 ⁄8
13 ⁄4
10 ⁄8
1
8 ⁄2
1
11 ⁄2
1
10 ⁄2
3
15 ⁄16
111⁄8
93⁄8
125⁄8
113⁄8
163⁄4
⁄2
1
⁄2
3
⁄4
7
⁄8
7
⁄8
3
6 ⁄4
8
1
3
11 ⁄4
1
N
3
⁄8
3
⁄8
3
⁄8
9
⁄16
9
⁄16
O
P
R
V
X
33⁄4
8
8
–
81⁄2
1
9 ⁄4
–
93⁄8
3
–
113⁄4
5
4 ⁄16
9
1
5 ⁄16 10
3
1
10 ⁄4
1
1
6 ⁄8
13 ⁄4
13 ⁄4 11 ⁄8
17
7
141⁄2
145⁄8 121⁄4
17
*Bore & "M" varies with frame.
26
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Pressure Blowers
DIRECT DRIVE - ARRANGEMENT 4
Pressure blowers are generally used on industrial applications for small
high pressure exhaust systems where air is laden with dust or grit and also for
supplying high pressure air for conveying and cooking. Not suitable for heavy,
coarse material. See p. 34.
WHEELS—Constructed with straight radial blades of heavy cast aluminum
for self cleaning features, dynamically balanced and designed for efficient
operation—Spark resistant. Suitable for 250°F Max.
CLOCKWISE ROTATION—Bottom Horizontal discharge is furnished
unless otherwise specified. Discharge position and rotation can be changed.
Rotation is as viewed from motor end. (See p.31.)
CW-BH Blower
ASSEMBLED AND TESTED - WITH BALL BEARING MOTOR
WHEN ORDERING: INCLUDE PHASE, VOLTS, ROTATION AND DISCHARGE
Model
No.
PW
PW
PW
PW
PW
8
9
11
12
14
HP
With Standard
Open Motor
1 Phase* 3 Phase
S
T
1
⁄3
1
⁄3
X
X
X
X
–
1
2
5
X
X
X
X
X
*Single phase is 115V or 230V
RPM
1
3500
3500
3500
3500
3500
291
526
800
1190
2280
2
3
231
470
741
1130
2180
CFM
Static pressure (inches water)
5
6
7
8
4
165
410
676
1065
2070
330
600
1000
1960
200
500
930
1840
400
860
1720
300
780
1570
9
690
1400
575
1240
10
11
410
1080
880
12
Ship
Wt.
Lb.
670
35
40
65
80
135
(X) Available models
ACCESSORIES
Special Motor
Model
PW
PW
PW
PW
PW
8
9
11
12
14
Chemical
Vibration Drive Resistant
3Ø
Pads Cover Coating
Enclosed
Exp.Proof‡
1Ø
3Ø
1Ø
X
X
X
–
–
X
X
X
X
X
X
X
X
–
–
‡See p. 5 for motor description
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
Disc.
Switch
X
X
X
X
X
X
X
X
X
X
(X) Available accessories
Outlet Velocity (FPM) =
CFM
Area (Sq. Ft.)
OV
[4005
]2
Vel. Press.=
Tip Speed (FPM)
At 3500 RPM = 916 x Dia. (in.)
Construction is of 16 gauge steel housings and
bases—Arc welded for rigidity.
Finish is Dark Gray Baked epoxy.
Blower Dimensions
Blower
Wheel
3
1
PW-8
7 ⁄4 x 2 ⁄4
PW-9
9 x 23⁄4
PW-11
105⁄8 x 3
PW-12
121⁄2 x 3
PW-14
131⁄2 x 43⁄8
Bore*
Certified Dimension Prints furnished upon request
OUTLET
A
B
C
D
E
F
1
11
8
3
3
5
7
1
121⁄8
8
31⁄2
31⁄2
55⁄8
7
143⁄4
9
4
31⁄2
67⁄8
71⁄2
17
8
5
4
8
61⁄2
71⁄8
53⁄4
8
99⁄16
⁄2
⁄2
5
⁄8
7
⁄8
11⁄8
175⁄8
111⁄4
INLET
P
R
16
4
5
6 ⁄8
1
8 ⁄2
203⁄4
5
71⁄2
93⁄8
75⁄8
203⁄4
6
85⁄8
95⁄8
201⁄8
7
22
8
G
H
J
K
L
1
3
5 ⁄8
7
4 ⁄8
7
5 ⁄8
7
5 ⁄8
1
63⁄8
53⁄4
67⁄8
63⁄4
71⁄4
61⁄2
8
81⁄4
71⁄2
9
101⁄2
95⁄8
113⁄8
⁄2
⁄2
3
⁄4
3
⁄4
1
11
O
X
S
T
V
13 ⁄8
12
–
145⁄8
16
–
113⁄4
181⁄4
16
–
10
105⁄8
183⁄8
15
–
111⁄2
125⁄8
211⁄2
15
71⁄4
1
*Could vary depending on motor frame size used.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
27
DIRECT DRIVE UTILITY BLOWERS
FORWARD CURVE WHEELS - SINGLE INLET - ARRANGEMENT 4
For general ventilation where duct systems are required. Compact, easy to mount and quiet in operation, these
blowers are designed to deliver large volumes of air economically. Ideal for wash rooms, boiler rooms, restaurants, and
small hood exhaust.
Note: Low static pressure systems may overload certain motors. Where this condition exists, increase the static pressure with duct work, dampers, etc.
CLOCKWISE ROTATION—Bottom horizontal discharge (as shown in photo) furnished unless otherwise specified.
DISCHARGE POSITION easily changed to any one of eight different positions. Rotation as viewed from the motor end.
(See page 31.)
Suitable for temperatures to 250°F. (500° with slinger)
Wheels are heavy gauge steel construction. Available with spark resistant aluminum wheels.
CW-BH Blower
ASSEMBLED & TESTED: With Open Ball Bearing Motor.
CFM
Model
HP
D5 A
A
D6
B
1
A
D8
C
⁄6
⁄6
1
⁄6
1
⁄6
1
⁄3
D9 C
14
D11 E
12
Static Pressure (inches water)
120v Single Phase 3 Phase
1 Speed 2 Speed 1 Speed
S
M
T
1
⁄
⁄
1
⁄8
1
184
390
595
169
330
560
144
250
515
112
100
470
420
365
300
1140
1750
760
1150
680
1085
620
1050
535
1005
430
960
915
865
RPM
0
1750
1140
1750
3
⁄4
1
⁄8
5
⁄2
3
⁄8
⁄4
60
X
X
X
X
X(v)
X
X
X
X(v)
X
X
–
X
–
X
X
X(v)
X
850
1140
875
1180
835
1160
780
1125
680
1090
470
1035
965
855
X
X
X
850
1140
1520
2060
1380
1970
1290
1870
1145
1800
1010
1710
860
1605
1500
(V) = Variable speed includes solid state control
Ship
Wt.
11⁄4
1
25
25
25
750
40
40
580
70
1290
80
1020
(X) Available models
HIGH SPEED UTILITY BLOWERS
For high static pressure applications such as garage monoxide systems, electronic cooling and installations requiring extra long duct lengths.
115/230V
CFM
Static pressure (inches water)
SINGLE PHASE THREE PHASE
Model
No.
D**
D9 E**
F**
F**
D11 G**
H**
1 Spd. 2 Spd.
1 Spd. 2 Spd.
HP
S
M
T
R
RPM
1/2
1
X
X
X
X
X
X
X
X
–
1750
1
X
X
X
X
X
1720
1
11⁄2
2
X
X
X
X
–
–
X
X
X
–
–
X
1750
X
X
X
⁄2
3
⁄4
1
3/4
1020 895
X
X
1675 1620
X
X
X
X
X
X
*120v or 230v 1Ø See p.10 for 208v 1Ø motors. **D9D Not available spark resistant or CCW.
EXTRAS
Model
No.
1 1/4
1 1/2
1 3/4
2
810
1550
1550
733
1445
1445
615
1290
1290
2 1/4
1100
1100
X
1900
2500
1465
1840
2415
1425
1730
2240
1280
1600
2130
2 1/2
Ship
Wt.
Lb.
2 3/4
60
70
80
1120
1450
1990
X = Low S.P. will cause motor overload.
910
1280
1850
100
110
120
1040
1660
(X) Available models
Spark Shutter
Chemical
XP
Vib. Resist. to fit
Heat Resist.
Motor‡
Pads Wheel Disch. Slinger Coating 1 Phase
Drive
Cover
D5
D6
D8
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
D9
D11
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*Square…Model A8 (Page 8) ‡See p. 5 for motor description (X)Available accessories
SEE PAGES 36, 37, 38 FOR SOLID PVC BLOWERS
BLOWER DIMENSIONS
Model
No.
D5
D6
D8
D9†
D11 E,H
D11 F
D11 G
Wheel
⁄4 x 21⁄2
61⁄4 x 3
73⁄4 x 37⁄8
1
9 x 4 ⁄2†
5
10 ⁄8 x 51⁄4
105⁄8 x 3
5
10 ⁄8 x 4
4
A
3
28
C
B
3
⁄8
93⁄8
8
11
⁄8
14 ⁄4
3
8
8
1
11
D
1
⁄8
73⁄8
81⁄4
3
10 ⁄4
3
11 ⁄4
5
7
8
1
12
*M varies with motor frame size
OUTLET
⁄2
3
⁄8
41⁄4
53⁄8
1
6 ⁄2
3
E
3
6
5
7
5
⁄8
6 ⁄8
5
7
8
F
⁄4
41⁄4
3
7
7
10
INLET
G
1
⁄2
1
⁄2
1
⁄2
1
⁄2
3
⁄4
H
1
3
⁄2
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
3
3
⁄4
L
M*
1
⁄2
117⁄8
121⁄2
1
13 ⁄4
151⁄2
4
⁄8
4
6
6
45⁄8
63⁄4
67⁄8
5
3
1
3
6
⁄4
8
⁄8
†D9, C, E, F wheel = 9 x 41⁄2
K
⁄8
5
7
5
J
3
3
⁄8
6 ⁄4
5
⁄4
9 ⁄8
5
7
3
1
⁄8
8 ⁄8
7
1
1
11
N
3
⁄8
3
⁄8
3
⁄8
3
⁄8
3
⁄8
O
P
R
3
4
4
⁄4
31⁄8
33⁄4
3
4 ⁄8
2
5
1
5
6
⁄8
71⁄8
8
8
81⁄2
9
10
1
⁄4
10 ⁄4
As above (D11) except as shown
D9D wheel = 9 x 3 (cw steel only)
CATALOG #37
www.centralfan.com
X
5
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
9
3
⁄4
81⁄2
7
9
⁄8
⁄4
3
11
BELT DRIVE UTILITY BLOWERS
Recommended for clean air ventilation where static pressures do not vary
over a wide range. Use backward curved blowers (next page) where system
conditions vary or pressure not known.
Not recommended for kitchen hood exhaust.
BLOWER
DIMENSIONS
PAGE 31
Wheel rotation and discharge position - page 31
Blower dimensions - page 31
Special motors and controls - page 12
CCW
SIZES SHOWN ARE NORMAL STOCK. OTHER SIZES ALSO AVAILABLE.
115/230v
SINGLE PHASE
Model
No.
A
B
8 C
D
E
A
B
9 C
D
E
B
C
11 D
E
F
C
D
12 E
F
G
D
E
15 F
G
H
E
F
18 G
H
J
HP
1
⁄6
⁄4
⁄3
1
⁄2
3
⁄4
1
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
1
1
1
⁄3
1
⁄2
3
⁄4
1
11⁄2
1
⁄2
⁄4
3
1
11⁄2
2
3
⁄4
1
11⁄2
2
3
3
⁄4
CCW-TH Blower
See Note Below for CFM vs. RPM vs. S.P. Relationship
THREE PHASE
1
@ ⁄4" S.P.
1 Speed 2 Speed 1 Speed 2 Speed Blower
S
M
T
R
RPM*
Approx. CFM*
Static pressure (inches water)
⁄4
1
11⁄2
2
O.V.
FPM
1
1
3
⁄4
⁄2
X
X
X
X
X
–
X
X
X
X
–
X
X
X
X
–
–
–
–
–
1200
1300
1400
1600
1800
2200
2700
2900
3400
4000
650
800
850
1000
1200
590
700
800
950
1150
560
650
750
900
1100
500
600
700
850
1050
X
X
X
X
X
–
X
X
X
X
–
X
X
X
X
–
–
–
–
–
800
900
1000
1200
1400
1700
2000
2200
2600
3000
800
950
1050
1200
1400
750
875
1000
1150
1350
650
800
950
1100
1300
600
750
850
1000
1250
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
X
700
800
900
1100
1200
1700
2000
2400
2700
3100
1100
1300
1500
1700
2000
1050
1200
1400
1600
1900
950
1100
1250
1550
1800
800
1000
1200
1500
1700
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
–
X
X
X
X
600
700
800
900
1000
1900
2200
2600
2900
3400
1650
1900
2200
2500
2900
1500
1750
2100
2400
2800
1300
1650
2000
2200
2700
1150
1500
1900
2150
2600
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
500
600
700
800
900
2000
2300
2600
2900
3300
2500
2900
3300
3700
4200
2350
2800
3200
3600
4100
2100
2700
3000
3500
3800
1900
2400
2800
3400
3700
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
400
500
550
600
700
1900
2200
2500
2800
3100
3600
4100
4700
5300
5800
3400
3800
4500
5000
5700
3200
3600
4300
4800
5600
2800
3400
4100
4700
5500
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
350
400
450
500
550
1900
2100
2400
2700
3100
4300
4800
5600
6200
7200
4000
4500
5300
6000
7000
3500
4200
5000
5700
6700
3000
3700
4700
5300
6500
E
F
20 G
H
J
1
11⁄2
2
3
X
X
X
X
X
F
G
22 H
J
K
1
11⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
350
400
425
475
500
2000
2400
2600
3000
3200
5600
6700
7300
8500
9000
5000
6200
6800
8000
9000
4700
5600
6400
7600
9000
4200
5200
6200
7400
9000
F
G
24 H
J
K
1
11⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
300
350
400
450
500
1900
2200
2500
2900
3500
6600
7700
8800
10000
12000
5900
7200
8300
9600
11600
5200
6600
7600
9000
11100
4200
5900
6900
8500
10500
500
650
800
950
3
Ship
Wt.
O.V. = 3.38 x CFM
60
2
500
750
900
1
⁄2
650
800
750
80
O.V. = 2.14 X CFM
750
950
1200
900
1100
1000
65
900
90
O.V. = 1.57 X CFM
1050
1350
1600
1500
1300
105
O.V. = 1.17 X CFM
1200
1700
2000
2500
1400
1700
2300
1500
2000
1800
O.V. = .78 X CFM
2000
2500
3100
3500
2100
2800
3300
2400
3000
2700
O.V. = .53 X CFM
2800
3600
4200
5300
3200
3800
4900
3500
4500
4100
4800
4100
180
200
265
290
300
340
400
420
6200
7800
5200
7400
7000
O.V. = .29 X CFM
5100
6000
7500
9800
160
320
4000
5500
O.V. = .35 X CFM
4600
5400
6700
8400
140
280
O.V. = .43 X CFM
3900
4800
6000
75
5000
6000
8900
5800
7800
6500
430
460
510
1
*Exhibited blower RPM (above) relates to ⁄4 " static pressure performance only. Higher RPM are necessary to yield the performance shown at higher static pressures.
AMCA CLASSIFICATION
FOR SPARK RESISTANT
CONSTRUCTION
TYPE A
All parts of the fan in contact with
the air or gas being handled shall
be made of nonferrous material.
Steps must also be taken to
assure that the impeller, bearings,
and shaft are adequately attached
and/or restrained to prevent a lateral or axial shift in these components.
Model
8
9
11
12
15
18
20
22
24
Weather
Vib.
Cover Isolators
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
†Max temp. for Type "B" = 250°F.
Disch.
Shutter
X
X
X
X
X
X
X
X
X
For special motors - p.10
Access
Door
X
X
X
X
X
X
X
X
X
Blower Dimensions: (Page 31)
TYPE B
The fan shall have a nonferrous impeller and nonferrous ring about the opening through which the shaft passes.
Ferrous hubs, shafts, and hardware are allowed provided construction is such that a shift of impeller or shaft will not
permit two ferrous parts of the fan to rub or strike. Steps must also be taken to assure that the impeller, bearings,
and shaft are adequately attached and/or restrained to prevent a lateral or axial shift in these components.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Drain
X
X
X
X
X
X
X
X
X
CATALOG #37
www.centralfan.com
Chem. Spark Resist.
Resist.
Coat°
B†
C
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
NOT AVAILABLE
See Page 30 for Backward Curve
Low static pressure can result in motor overload on blowers designed to operate at higher static pressures.
°Coatings described p. 38
Heat
Slinger
500°F
X
X
X
X
X
X
X
X
X
Disc.
Switch
X
X
X
X
X
X
X
X
X
(X) Available acces-
TYPE C
The fan shall be so constructed that a shift
of the impeller or shaft will not permit two
ferrous parts of the fan to rub or strike.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
29
ULTRAFAN-PAK
BELT DRIVE UTILITY BLOWERS
NON-OVERLOADING
• Baked epoxy finish standard.
• Heavy gauge all welded construction.
AIR FOIL CONSTR.
STD. FOR SIZE 270
AND LARGER
• 250°F max. operating temp. (500°F with heat slinger)
• Full class I performance to 5" static pressure…AMCA certified.
• Self-aligning pillow block ball bearings with grease fitting (100,000 hrs.)
• Available in CW or CCW rotation and eight different discharge positions. (see next page)
• Suitable for kitchen hood exhaust, dirt laden air, or where system pressures may
vary or are unknown.
CW-BH Blower
SINGLE PHASE
Model
No.
C
D
105 E
F
D
E
122 F
G
D
E
135 F
G
THREE PHASE
1 Speed 2 Speed 1 Speed 2 Speed
HP
S
M
T
R
1
⁄3
1
⁄2
3
⁄4
1
1
⁄2
⁄4
3
1
11⁄2
1
⁄2
3
⁄4
1
11⁄2
3
⁄4
@1⁄2" S.P.
Blower
RPM
O.V.
FPM
1
⁄2
3
1
⁄4
1
1
⁄2
Approx. CFM*
Static pressure (inches water)
1
2
21⁄2
3
3 ⁄2
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
X
2069
2474
2890
3167
2100
2500
3000
3300
1300
1600
1900
2100
1200
1500
1800
2000
1100
1400
1700
1900
900
1300
1600
1800
700
1000
1400
1700
800
1300
1500
1000
1400
X
X
X
X
X
X
X
–
X
X
X
X
X
X
X
X
1744
1964
2187
2484
2300
2700
3000
3500
2000
2300
2600
3000
1800
2200
2500
2900
1700
2100
2400
2800
1400
1900
2200
2600
1200
1600
2000
2500
1300
1700
2300
1500
2100
X
X
X
X
X
X
X
–
X
X
X
X
X
X
X
X
1454
1666
1886
2107
2100
2500
2900
3300
2200
2600
3000
3400
2100
2500
2800
3300
1900
2300
2700
3200
1400
2000
2400
3000
1600
2100
2700
1700
2500
2200
X
X
–
–
X
X
X
X
X
X
X
X
1490
1652
1900
2106
2400
2700
3200
3600
3100
3500
4100
4600
2800
3200
3900
4400
2600
3000
3700
4200
2100
2600
3300
3900
1700
2200
3000
3500
2600
3300
2000
2900
800
1200
⁄2
1500 CFM Max. @ 5"
2 HP**
2400 CFM Max. @ 5"
3 HP**
1
1
1 ⁄2
2
F
G
165 H
J
1
11⁄2
2
3
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
1391
1604
1789
2070
2500
3000
3300
3900
3900
4600
5200
6100
3600
4400
5000
5900
3300
4100
4700
5700
2800
3600
4300
5200
2100
3200
3900
4800
2700
3400
4500
3000
4100
F
G
182 H
J
1
1
1 ⁄2
2
3
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
1195
1358
1501
1740
2300
2700
3000
3500
4300
5000
5600
6600
3900
4800
5400
6400
3600
4500
5200
6200
3000
3900
4900
5700
3400
4200
5300
3600
4900
3000
4500
G
H
200 J
K
11⁄2
2
3
5
X
X
X
–
–
–
–
–
X
X
X
X
X
X
X
X
1169
1293
1453
1759
2500
2800
3200
3900
5700
6400
7300
9000
5400
6100
7200
8800
5000
5800
7000
8600
4300
5100
6300
8200
3400
4500
6000
7700
3500
5300
7300
4500
6800
G
H
222 J
K
11⁄2
2
3
5
X
X
X
–
–
–
–
–
X
X
X
X
X
X
X
X
954
1051
1214
1418
2300
2600
3000
3600
6500
7300
8600
10200
6100
6900
8200
9800
5600
6500
7900
9700
4500
5600
7000
9300
4500
6400
8700
5400
7900
G
H
245 J
K
L
11⁄2
2
3
5
71⁄2
X
X
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
810
897
1035
1233
1419
2100
2400
2800
3400
4000
7300 6600 5900
8300 7700 7200
9800 9300 8900
11900 11500 11100
13900 13500 13000
4500
5900
7700
10300
12300
6600
9500
11600
8800
7600
10800 10000
9300
H
J
270 K
L
2
3
5
71⁄2
X
X
–
–
–
–
–
–
X
X
X
X
X
X
X
X
936
1046
1261
1448
2100
2400
2900
3400
8800 8000 7400
10000 9600 9200
12300 12000 11300
14300 14000 13600
6300
5000
8100
7100
10600
9500
12900 12000
6200
8800
8100
11000 10500
7300
9600
H
J
300 K
L
2
3
5
1
7 ⁄2
X
X
–
–
–
–
–
–
X
X
X
X
X
X
X
X
839
980
1177
1328
2100
2500
3100
3500
10800 9600 8700
12900 12000 11000
15800 15100 14200
18000 17600 17000
6700
9400
7400
12900 11400
16000 14200
10300
8500
13300 12600
J
K
330 L
M
3
5
1
7 ⁄2
10
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
–
859
1053
1213
1246
2400
3000
3500
3900
15000
18800
21900
24200
10000
14300 12300
17700 16000
20800 19500
10000
8200
14400 13000
18000 16700
3000 CFM Max. @ 5"
5 HP**
2500
3500 CFM Max. @ 5"
5 HP**
3800
4400 CFM Max. @ 5"
5 HP**
3900
5000 CFM Max. @ 5"
5 HP**
6200
6500 CFM Max. @ 5"
7 1⁄2 HP**
7300
6300
7900 CFM Max. @ 5"
10 HP**
9200 CFM Max. @ 5"
10 HP**
12000 CFM Max. @ 5"
15 HP**
10700
14000 CFM Max. @ 5"
15 HP**
15000
*CFM Exhibited is max for HP shown. Each model is capable of higher CFM than shown if equipped with larger motors at higher blower RPM. Note max. motor sizes.
**Max. motor size 2-speed switches - page 10. (X) Available models
30
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
5
1800
X
X
X
X
12600
16100
20000
22200
1
4
2000 CFM Max. @ 5"
3 HP**
E
F
150 G
H
13500
17200
21000
23500
4
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
ULTRAFAN-PAK
Max.
Disch.
CFM*
Shutter (75% F.A.)
Vib.
Isolators
Weather
Cover
Model
Access
Door
Drain
Chem.
Resist.
Coat**
Spark Resist.‡
Blower with Motor
B
C
Heat
Slinger
Disc.
Switch
Ship Wt.
HP
105
122
X
X
X
X
X
X
1400
1900
X
X
X
X
X
X
X
X
X
X
X
X
X
X
100
190
1
11⁄2
135
150
X
X
X
X
X
X
2300
2800
X
X
X
X
X
X
X
X
X
X
X
X
X
X
210
230
11⁄2
2
165
182
X
X
X
X
X
X
2900
3500
X
X
X
X
X
X
X
X
X
X
X
X
X
X
280
350
3
3
200
222
X
X
X
X
X
X
4300
5200
X
X
X
X
X
X
X
X
X
X
X
X
X
X
480
480
5
5
245
270
X
X
X
X
X
X
6300
7700
X
X
X
X
X
X
X
X
X
X
X
X
X
X
620
720
71⁄2
71⁄2
300
330
X
X
X
X
X
X
9400
9500
X
X
X
X
X
X
X
X
X
X
X
X
X
X
820
1100
71⁄2
10
*When centrifugal fan outlet velocities exceed 2000 ft/min. shutters and other fittings should be located at least 21⁄2 duct diameters of straight duct
from the blower discharge. Unpredictable shutter performance will result if the shutter is on the blower discharge. Blower performance is enhanced by
a properly designed expander (evasé) mounted on the discharge. Shutters ( and other fittings) should be installed downstream of the evasé.
**See p. 38 for coatings and pp. 36 and 37 for PVC and FRP blowers. ‡See p. 29 for spark resistant construction. (X) Available accessories
Blower Rotation & Discharge Designation (viewed from drive side)
Peerless ULTRAFAN-PAK Class I Arr. 10
OUTLET (OUTSIDE)
DIMENSIONS
Shaft
Dia.
Size Size Wheel
FC BC
Dia. CL. 1
8
73⁄4
9
9
105
15
10 ⁄2
101⁄2
11
12
1
3
⁄4
3
⁄4
3
⁄4
3
⁄4
INLET (OUTSIDE)
TH, DB, BH, UB
Straight Disch.
A
B
Max.
Motor
Frame
BAU, TAU, TAD, BAD
Angular Disch.
C
D
E
F
H
J
K
L
H
J
K
L
M
N
P
Q
R
S
91⁄8 13
81⁄4
53⁄8
141⁄4
71⁄2
6
45⁄8
63⁄4
67⁄8
103⁄8
61⁄4
73⁄8
51⁄4
201⁄8
33⁄4
8
–
–
18
181⁄2
103⁄8 13
103⁄4
61⁄2
141⁄4
83⁄8
63⁄4
55⁄8
73⁄4
71⁄8
115⁄8
71⁄2
81⁄4
61⁄8
203⁄4
45⁄16
9
–
–
18
181⁄2
3
7
3
1
1
7
5
1
7
3
1
1
5
7
1
T
12 ⁄8 13
11 ⁄4
8
14 ⁄4
10 ⁄4
7 ⁄8
6 ⁄4
9 ⁄8
8 ⁄16
13 ⁄4
8 ⁄8
9 ⁄8
7 ⁄8
19 ⁄8
6
12 ⁄8
–
–
20 ⁄2
17
127⁄8 13
113⁄4
8
141⁄4
103⁄4
77⁄8
63⁄4
91⁄8
81⁄16
131⁄4
87⁄8
95⁄8
71⁄8
211⁄2
51⁄8
10
–
–
201⁄2
17
95⁄8
237⁄8
63⁄8
131⁄4
111⁄4
123⁄4
251⁄4
20
122
121⁄4
1
163⁄8 131⁄2 131⁄4
95⁄8
131⁄2
143⁄4
101⁄8
81⁄2
111⁄2
101⁄2
165⁄8
103⁄4
121⁄2
135
131⁄2
1
175⁄8 131⁄2 145⁄8 103⁄4
131⁄2
16
111⁄8
93⁄8
125⁄8
113⁄8
181⁄4
117⁄8
133⁄4
10
243⁄8
7
141⁄2
123⁄8
137⁄8
257⁄8
20
150
15
1
191⁄4 151⁄2 161⁄4 113⁄4
151⁄2
175⁄8
123⁄8
103⁄8
141⁄8
123⁄8
201⁄8
131⁄4
151⁄4
111⁄8
267⁄8
71⁄2
161⁄8
133⁄8
147⁄8
275⁄8
22
165
161⁄2
1
213⁄8 15
151⁄2
193⁄4
135⁄8
113⁄8
151⁄2
135⁄8
217⁄8
145⁄8
163⁄4
121⁄4
271⁄2
81⁄2
177⁄8
141⁄2
17
301⁄8
22
1
3
7
173⁄4 13
5
1
1
1
5
1
5
1
1
5
5
18
182
18 ⁄4
1 ⁄16
23 ⁄8 17
19 ⁄8 14 ⁄4
17 ⁄2
21 ⁄2
15
12 ⁄8
17 ⁄8
14 ⁄8
24 ⁄8
16
18 ⁄2
13 ⁄8
30 ⁄8
20
200
20
13⁄16
25
211⁄2 157⁄8
17
233⁄8
161⁄2
133⁄4
183⁄4
153⁄4
263⁄8
175⁄8
203⁄8
147⁄8
311⁄2
22
222
221⁄4
13⁄16
273⁄8 161⁄2 24
173⁄8
17
253⁄4
181⁄4
151⁄4
207⁄8
171⁄4
29
191⁄2
225⁄8
161⁄2
24
245
241⁄2
17⁄16
301⁄4 161⁄2 261⁄4 191⁄4
163⁄4
235⁄8
201⁄8
167⁄8
23
197⁄8
321⁄2
211⁄2
247⁄8
270
27
17⁄16
33
211⁄4
161⁄2
261⁄4
221⁄8
181⁄2
251⁄4
211⁄2
353⁄8
235⁄8
300
30
111⁄16
361⁄4 161⁄2 321⁄4 233⁄8
161⁄2
291⁄2
245⁄8
201⁄2
281⁄8
235⁄8
393⁄8
330
33
111⁄16
391⁄2 213⁄8 353⁄8 257⁄8
215⁄8
331⁄8
271⁄8
221⁄2
307⁄8
255⁄8
43
17
161⁄2 29
1
5
3
1
3
19 ⁄8
15 ⁄4
18 ⁄4
33 ⁄8
25
10
211⁄2
177⁄8
201⁄8
361⁄4
25
323⁄4
105⁄8
237⁄8
193⁄8
225⁄8
393⁄4
26
181⁄4
335⁄8
113⁄4
263⁄8
211⁄4
241⁄2
427⁄8
26
273⁄8
20
345⁄8
125⁄8
29
233⁄4
261⁄2
47
26
263⁄8
301⁄2
221⁄4
36
133⁄4
321⁄4
26
283⁄4
517⁄8
27
287⁄8
331⁄2
243⁄8
413⁄8
15
353⁄8
283⁄8
311⁄8
581⁄8
303⁄8
9 ⁄8
V
7
⁄16
7
⁄16
7
⁄16
7
⁄16
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
1
⁄2
7
⁄8
X
Size
12
145T
12
145T
14
145T
14
145T
17
182T
17
182T
177⁄8
182T
191⁄2
184T
217⁄8
184T
233⁄4
213T
261⁄8
213T
273⁄4
215T
301⁄2
215T
333⁄4
254T
383⁄8
254T
NOTE: Letters “C” and “D” are outside housing dimensions.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
31
New York General Purpose Blowers
BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10
• FULL AMCA CLASS II CONSTRUCTION—
Rugged heavy gauge steel construction for dependable, trouble free
heavy duty service.
• AIRSTREAM TEMPERATURES TO 650°F—
Heat slingers for temperature > 200°F
Sizes 12 and 15 require PLR wheel > 200°F
• CHOICE OF TWO WHEEL DESIGNS — BOTH STOCKED
Acoustafoil-airfoil blade is quieter and more efficient for relatively clean air
PLR-flat BC blade for particulate laden air.
• STABLE PERFORMANCE FOR VAV SYSTEMS—
Acoustafoil wheel yields stable pressure curve from wide open to completely closed off.
• Motors are standard ODP
See p.10 for special motors
CW-TH
CW Rotation
SEE P.33 FOR
BLOWER DIMENSIONS
Performance data exhibited are for the acoustafoil wheel and depict typical maximum CFM at designated motor HP. Complete AMCA certified data
are available. PLR wheel performance will be different, especially for higher S.P. and corresponding low CFM. Both AcF and PLR models are stocked.
Acoustafoil
SINGLE PHASE
Model
No.
HP
3
⁄4
THREE PHASE
@ 2" S.P.
1 Speed 2 Speed Blower
T
R*
RPM
O.V.
FPM
–
–
–
–
–
–
2500
2800
3250
3600
3800
–n
1800
2200
2700
3200
3400
3400
1 Speed
S
2 Speed
M
X
–
–
–
–
–
X
X
X
X
X
X
E
F
G
123 H
J
K
1
1
1 ⁄2
2
3
5
X
X
X
X
X
X
F
G
153 H
J
K
L
1
1
1 ⁄2
2
3
5
1
7 ⁄2
X
X
X
X
X
X
X
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
–
–
1940
2220
2480
2860
2966
–n
1800
2300
2700
3300
3400
3400
G
H
J
183 K
L
M
1 ⁄2
2
3
5
1
7 ⁄2
10
1
X
X
X
X
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
–
–
–
1550
1720
2000
2352
–n
–n
1800
2200
2800
3400
3400
3400
H
J
K
223
L
M
N
2
3
5
1
7 ⁄2
10
15
X
X
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
–
–
1250
1500
1800
2012
–n
–n
1700
2300
3000
3400
3400
3400
J
K
273 L
M
N
P
3
5
1
7 ⁄2
10
15
20
X
–
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
–
–
–
1000
1220
1420
1563
–n
–n
1800
2500
3100
3400
3400
3400
K
L
M
303 N
P
W
5
1
7 ⁄2
10
15
20
25
–
–
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
–
–
–
–
1020
1180
1345
1397
–n
–n
2200
2800
3300
3400
3400
3400
L
M
N
333
P
W
X
7
10
15
20
25
30
–
–
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
–
–
–
–
–
1000
1120
1270
–n
–n
–n
2500
3000
3400
3400
3400
3400
1
⁄2
*2 speed - 1 winding
See page 10 for special motors and motor controls.
1
1
⁄2
1
2230
2550
2920
2923
1930
2250
2680
2923
1
⁄2
1740
2060
2540
2920
2923
MAX. Speed - 4900 RPM
3340
3850
4350
4385
2900
3580
3920
4385
3050
3200
3750
4385
Model AcF Approx. CFM
Static Pressure (inches water)
1
2
2 ⁄2
3
4
5
1520
1870
2340
2710
2923
1275
1600
2180
2520
2923
1030
1380
2000
2370
2923
(687)
950
1610
2040
2610
2923
(687)
(687)
(687)
1200
1700
2385
2923
765
1350
2100
2923
1400
2600
2300
2930
3400
4280
4385
1900
2610
3130
3930
4385
1500
2390
2900
3770
4385
(1031)
1600
2420
3300
4385
(1031)
(1031)
(1031)
1650
2840
4280
4385
2000
3700
4385
1000
2900
4127
3460
4225
5320
6527
2850
3780
4960
6527
2115
3100
4560
6200
6527
(1535)
1900
3600
5450
6527
(1535)
(1535)
(1535)
2420
4730
6500
6527
1500
3840
5800
6527
2000
4300
6100
4700
6500
8500
9689
3800
5600
7900
9689
2650
4800
7350
9400
9689
(2279)
3280
5900
8300
9689
(2279)
(2279)
(2279)
4560
7000
9100
9689
2950
6000
8100
9689
3200
5680
9100
7100
10400
12800
14245
6000
9500
11900
14245
4300
8400
11000
13400
14245
(3351)
3800
9500
12000
14245
(3351)
3355
7000
10400
14000
14245
(3351)
(3351)
4800
8200
12550
14245
4180
9150
12700
11200
14000
16900
17600
10000
13000
15700
17600
8400
12000
14800
17600
4750
9400
13000
16600
17600
(4135)
6300
10000
14800
17600
(4135)
4000
7200
13000
16200
17600
(4135)
15800
18000
21300
14000
17200
21300
12700
16000
20050
21300
8700
13000
18000
21300
5500
9200
15400
19000
21300
(5007)
6200
12300
17000
20500
21300
(5007)
Max. Speed - 3800 RPM
4980
5620
6500
4570
5280
6100
6527
4150
4800
5680
6527
Max. Speed - 3005 RPM
6950
8500
9689
6300
7880
9650
9689
5600
7000
9100
9689
Max. Speed - 2570 RPM
10850
13000
14245
9500
12000
14245
8700
11000
13700
14245
Max. Speed - 2010 RPM
15000
17600
14000
16400
17600
12700
15000
17600
Max. Speed - 1805 RPM
19000
21300
18000
21000
21300
17000
19800
21300
Max. Speed - 1650 RPM
6
8
7700
12200
15800
6260
11200
16000
19000
(X) Available models
ACCESSORIES
Set of
Vib. Disch. Access
Pads Shutter Door
X
X
X
X
X
X
Chem. Spark Resist.‡
Resist.
Drain Coating*
B
C
X
X
X
X
X
X
X
X
AcF
Model
123
153
Drive
Cover
X
X
183
223
X
X
X
X
X
X
X
X
X
X
X
X
X
X
273
303
333
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
See page 33 for blower dimensions. Solid PVC and FRP blowers pp. 36 and 37.
(X) Available accessories
32
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Disc.
Switch
X
X
Heat
Slinger
X
X
Bare
Wt.
145
195
X
X
X
X
X
X
300
425
X
X
X
X
X
X
X
X
X
645
720
940
*Blower coatings p.38.
‡See p. 29 for description
CATALOG #37
www.centralfan.com
AMCA Spark Resist Options
TYPE B: Blower equipped with Aluminum
wheel and shaft ring. (Not suitable for abrasive or 200°F plus. Use Type C.)
TYPE C: Blower equipped with non-ferrous
inlet cone, non-ferrous rubbing blocks, and
ring at housing opening thru which shaft
passes.
See p. 29 for AMCA spark resist. options.
SEE P. 33 FOR AVAILABLE
DISCHARGE POSITIONS
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
New York General Purpose Blower
BACKWARD CURVE - BELT DRIVE - SINGLE INLET - ARRANGEMENT 10
AVAILABLE FAN DISCHARGES - VIEWED FROM DRIVE SIDE
NEW YORK GEN. PURPOSE BLOWER - CLASS 2 -ARR. 10 - PLR WHEEL AND ACOUSTAFOIL WHEEL
DIMENSIONS (INCHES)
OUTLET
INLET
OUTLET
Model
A
B
C
D
E
F
G
H
J
K
L
M
12
15
18
22
27
30
33
151⁄2
171⁄2
211⁄4
251⁄2
321⁄2
321⁄2
391⁄2
10
12
14
17
201⁄2
221⁄2
241⁄2
123⁄8
151⁄8
181⁄2
221⁄2
271⁄4
303⁄8
333⁄8
133⁄4
167⁄8
201⁄2
247⁄8
301⁄4
331⁄2
367⁄8
77⁄8
93⁄4
113⁄4
143⁄8
173⁄8
193⁄8
211⁄4
13
157⁄8
193⁄8
235⁄8
285⁄8
317⁄8
35
103⁄8
123⁄4
151⁄2
187⁄8
227⁄8
253⁄8
28
313⁄16
365⁄16
3813⁄16
457⁄8
511⁄4
531⁄2
583⁄4
21⁄8
31⁄8
31⁄8
31⁄8
41⁄8
41⁄8
41⁄8
21⁄2
3
31⁄2
4
5
51⁄2
6
131⁄2
161⁄2
20
241⁄2
30
33
361⁄2
93⁄8
113⁄8
137⁄8
167⁄8
203⁄8
225⁄8
247⁄8
Shaft
Model
R
S
T
V
W
a
b
c
d
Dia.
12
15
18
22
27
30
33
65⁄8
75⁄8
93⁄8
113⁄8
133⁄8
141⁄2
155⁄8
163⁄8
183⁄8
173⁄8
203⁄8
203⁄4
203⁄4
233⁄4
73⁄8
87⁄8
93⁄8
107⁄8
135⁄8
135⁄8
16
61⁄2
8
81⁄4
93⁄4
113⁄4
113⁄4
14
8
91⁄2
101⁄4
113⁄4
143⁄4
143⁄4
17
115⁄8
141⁄8
171⁄4
21
253⁄8
281⁄4
311⁄8
161⁄4
193⁄4
235⁄8
283⁄4
343⁄4
383⁄8
421⁄8
127⁄8
153⁄4
191⁄8
231⁄4
281⁄4
313⁄8
345⁄8
91⁄4
113⁄8
137⁄8
163⁄4
203⁄8
225⁄8
251⁄4
17⁄16
17⁄16
111⁄16
115⁄16
115⁄16
115⁄16
23⁄16
*Approximate shipping weight in lbs.
Model no. is approx. wheel dia.
Keyway
Base
holes
3
⁄8 x 3⁄16
3
⁄8 x 3⁄16
3
⁄8 x 3⁄16
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
9
⁄16
9
⁄16
9
⁄16
9
⁄16
3
⁄4
3
⁄4
3
⁄4
N
1915⁄16
2115⁄16
2115⁄16
26
267⁄8
267⁄8
297⁄8
CATALOG #37
www.centralfan.com
Q
61⁄8
71⁄4
83⁄4
101⁄4
121⁄2
133⁄8
143⁄4
Maximum
motor frame**
Bare
fan
weight*
Open
TE
145
195
300
425
645
720
940
184T
215T
215T
256T
284T
284T
324T
184T
215T
215T
254T
254T
254T
286T
**These maxima can be exceeded on most model sizes. . . with special assembly techniques
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
O
311⁄2
359⁄16
389⁄16
455⁄8
501⁄2
523⁄4
58
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
Tolerance: ±
1
⁄8"
33
NEW YORK G.I. BLOWERS
GENERAL INDUSTRIAL - BELT DRIVEN - FLAT RADIAL WHEELS
INDUSTRIAL AIR-MOVING APPLICATIONS
• Dust Collection
• Combustion air
• Pneumatic Conveying
• Heat recovery
• Moisture blow-off
• Incinerators
• Oven and dryer exhaust
(NICKELALUMINUM
BRONZE)
CW-TH
LS WHEEL
(STEEL)
CW-UB
Models 144 & Larger
Series 20 Arrangement 10
Flat radial-blade design best for material-conveying applications with airstreams containing
coarse material or heavy dust and particulate.
Models 85, 106, 126 – With nickel-aluminum bronze wheel 180°F Max. temp. (300° with heat
slinger)
Model 144 & up - With steel wheels Type LS 200°F Max. temp. (600° with heat slinger)
Compact Models 85, 106, 126
Arrangement 9
AMCA CERTIFIED
AMCA CERTIFIED
ASSEMBLED & TESTED- WITH OPEN BALL BEARING MOTOR & ADJUSTABLE SHEAVE DRIVE
1
⁄4
⁄3
1
⁄2
3
⁄4
1
⁄2
3
⁄4
B
C
85 D
E
X
X
X
X
1
D
E
106 F
G
H
X
X
X
X
X
1
11⁄2
2
3
⁄4
E
F
126 G
H
J
X
X
X
X
X
1
11⁄2
2
3
Series
20
3 PHASE
1 SP
2 SP‡
T
R
1 PHASE*
Model
No.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
1
⁄4
1
⁄2
1
2
3
–
3360
3585
4050
330
380
470
556
300
351
465
530
230
310
415
505
145
230
345
465
60
145
270
392
2780
3000
3250
3580
3890
740
880
1000
1200
–n
695
850
1000
1100
–n
640
790
920
1050
1200
520
670
810
970
1100
420
560
700
900
1040
300
500
620
830
960
2400
2520
2830
3000
3300
1140
1270
–n
–n
–n
1100
1250
1400
–n
(Max. Safe
1000
840
700
1160
990
870
1380
1240
1100
1300
–n
1400
RPM = 4000 @ 70°F)
580
750
990
1210
1440
4
6
8
10
–n (Max. safe RPM = 4800 @ 70°F)
60
–n
–n
–n
220
60
–n
–n
345
235
–n
–n
60
70
122 (RPM Max. = 4600 @70°F)
300
180
–n
500
350
250
710
575
465
860
750
630
280
490
780
1000
1300
–n
200
600
790
1175
–n
–n
360
640
1010
75
90
100
130
Exhibited performance data are condensed. Each blower can be equipped
to perform at greater capacity with higher RPM and HP.
3 PHASE
1 SPD
S
2 SPD
M
1 SPD
T
2 SPD‡
R
Fan
RPM**
CFM @ Static Pressure (in. water)
8
10
14
16
2
4
6
F
G
144 H
J
K
1
11⁄2
2
3
5
X
X
X
X
X
X
–
–
–
–
X
X
X
X
X
X
X
X
X
–
2000
2110
2360
2510
2870
1120
1460
1710
2100
2500
770
1050
1300
1710
2300
420
774
1035
1440
2050
G
H
174 J
K
L
11⁄2
2
3
5
71⁄2
X
X
X
X
X
–
–
–
–
–
X
X
X
X
X
X
X
X
–
–
1680
1751
1900
2150
2400
1750
2150
2660
3400
3800
1200
1520
2140
2850
3600
720
1100
1600
2400
3100
G
194 H
J
K
1
1 ⁄2
2
3
5
X
X
–
–
–
–
–
–
X
X
X
X
X
X
X
X
1446
1504
1618
1822
1975
2350
2850
3600
1250
1650
2250
3100
700
1100
1700
2600
H
J
224 K
L
M
2
3
5
71⁄2
10
X
X
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
–
–
1220
1300
1430
1585
1720
2750
3500
4550
5220
5600
1800
2680
3800
4670
5400
1100
1800
3000
4100
4950
J
K
264 L
M
N
3
5
71⁄2
10
15
X
–
–
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
–
–
1070
1150
1270
1375
1490
3850
5200
6300
7100
8000
2700
3950
5300
6340
7200
1700
3000
4300
5280
6800
2200
3400
4500
6050
K
L
294 M
N
P
5
71⁄2
10
15
20
–
–
–
–
–
–
–
–
–
–
X
X
X
X
X
–
–
–
–
–
970
1060
1130
1250
1320
6030
7400
8400
9800
11000
4400
6000
7260
9100
10000
2900
4600
5900
7800
9200
2080
3400
4700
6678
8480
HP
Ship
Wt.
Lbs.
CFM @ Static Pressure (in. water)
Fan
RPM**
NOT AVAILABLE
HP
1 PHASE*
1 SPD 2 SP
S
M
NOT AVAILABLE
Compact
Model
No.
500
775
1200
1720
635
1250
2050
2750
517
950
1530
518
1200
880
1750
2440
1100
1800
18
22
(Max. RPM @ 70°F = 4600)
180
1020
225
800
430
(Max. RPM @ 70°F = 3745)
235
760
1600
330
1300
750
(Max. RPM @ 70°F = 3114)
600
1250
2100
800
1700
950
1750
2750
3600
1800
2700
1300
2700
3720
5250
1240
2400
3950
2500
3800
5700
7300
2100
3940
5460
365
420
(Max. RPM @ 70°F = 2635)
1120
2300
3350
4200
Ship
Wt.
Lbs.
1310
2230
1850
920
500
580
(Max. RPM @ 70°F = 2280)
635
1760
3380
720
2860
1736
(Max. RPM @ 70°F = 1995)
890
3180
4700
990
2500
4100
2600
**Fan RPM listed will result in CFM shown @ 4" S.P. Other CFM exhibited are maxima at corresponding S.P. and motor HP, and will require other RPM.
‡ One winding
See page 10 for special motors. *120v or 230v 1Ø See page 10 for 208v. 1Ø (X) Available models
AMCA Spark Resistant Options
ACCESSORIES
Model
Drive
Cover
Vib.
Isolators
Drain
Fitting in
Housing
Bolted
Access
Door
Bare
Blower
TYPE C
Spark
Resist.
Heat
Slinger
Chemical
Resistant
Coating†
Inlet
Flange◊
Outlet
Flange◊
Disc.
Swich
85
106
126
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*
*
*
X
X
X
X
X
X
–
–
–
–
–
–
X
X
X
144
174
194
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
224
264
294
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*Models 85, 106 and 126 are not available as Type C. They are avail. as Type B
34
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
†See p. 38 for coatings. ◊Welded to housing (X) Available accessories
CATALOG #37
www.centralfan.com
TYPE B: Blower equipped with
non-ferrous wheel and shaft ring.
(Not suitable for abrasives or
200°F plus. Use Type C.)
TYPE C: A spark-resistant alloy
buffer attached to the housing
interior adjacent to the wheel front
and back and a buffer at the housing shaft opening. Suitable to
600°F w/slinger. (Series 20 only)
Dimensions p. 35
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
NEW YORK
GEN. INDUSTRIAL
BLOWER
ARR. 10
LS WHEEL
(STEEL)
L, M, & D ARE OUTSIDE DIMENSIONS
DIMENSIONS (Inches)
OUTLET
INLET
OUTLET
Size
A
B
C
D
E
F
G
H
J
K
L
M
N
O
144
174
194
224
151⁄2
171⁄2
211⁄4
251⁄2
101⁄2
125⁄8
14
161⁄2
111⁄8
131⁄8
16
187⁄8
81⁄4
101⁄8
101⁄4
13
93⁄8
111⁄8
117⁄8
14
12
141⁄2
18
211⁄4
101⁄4
121⁄4
137⁄8
163⁄8
30
341⁄8
363⁄8
413⁄8
15⁄8
15⁄8
31⁄8
31⁄8
21⁄2
3
31⁄2
4
9
11
11
13
77⁄8
91⁄2
93⁄4
103⁄4
20
22
22
26
197⁄8
217⁄8
337⁄8
387⁄8
264
294
334
364
28
321⁄2
391⁄2
391⁄2
181⁄2
21
23
251⁄2
213⁄4
245⁄8
273⁄8
301⁄4
15
167⁄8
183⁄4
203⁄4
161⁄8
181⁄4
203⁄8
221⁄2
241⁄2
273⁄4
307⁄8
341⁄8
187⁄8
213⁄8
237⁄8
263⁄8
441⁄2
48
531⁄8
56
41⁄8
41⁄8
41⁄8
51⁄4
41⁄2
51⁄2
6
6
15
17
19
21
123⁄8
14
155⁄8
171⁄4
26
267⁄8
297⁄8
30
411⁄2
44
485⁄8
503⁄8
Size
Q
R
S
T
V
W
a
b
c
d
Shaft
diameter
144
174
194
224
–
–
6
61⁄2
57⁄8
65⁄8
71⁄4
81⁄4
163⁄8
183⁄8
173⁄8
203⁄8
73⁄8
87⁄8
93⁄8
107⁄8
61⁄2
8
81⁄4
93⁄4
8
91⁄2
101⁄4
113⁄4
103⁄4
131⁄8
15
175⁄8
16
191⁄4
225⁄8
265⁄8
111⁄2
133⁄4
17
20
93⁄4
111⁄2
13
151⁄4
17⁄16
17⁄16
111⁄16
115⁄16
264
294
334
364
77⁄8
85⁄8
93⁄8
101⁄4
93⁄8
101⁄8
11
117⁄8
197⁄8
203⁄4
233⁄4
233⁄4
121⁄4
135⁄8
16
16
11
113⁄4
14
14
13
143⁄4
17
17
201⁄4
23
253⁄4
281⁄2
303⁄8
343⁄8
381⁄8
421⁄8
23
261⁄8
291⁄4
321⁄4
171⁄2
197⁄8
223⁄8
245⁄8
115⁄16
115⁄16
23⁄16
23⁄16
Keyway
⁄8 x 3⁄16
⁄8 x 3⁄16
3
⁄8 x 3⁄16
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
1
⁄2 x 1⁄4
Base
holes
3
9
3
9
⁄16
⁄16
9
⁄16
9
⁄16
3
⁄4
3
⁄4
3
⁄4
3
⁄4
NEW YORK COMPACT G.I. BLOWER NICKEL—ALUMINUM—BRONZE RADIAL WHEEL
ARRANGEMENT 9
DIMENSIONS (Inches)
OUTLET
Model
85
106
126
INLET
A
B
C
D*
E
F
G
H
101⁄2
101⁄2
121⁄2
6
71⁄2
81⁄2
63⁄8
77⁄8
10
45⁄8
55⁄8
7
53⁄8
65⁄8
71⁄2
67⁄8
81⁄2
111⁄4
57⁄8
71⁄4
83⁄4
17
19
221⁄8
Dimensions should not be used for construction unless certified.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
OUTLET
L*
M*
N
5
6
8
35⁄8
55⁄8
55⁄8
101⁄4
101⁄4
125⁄8
R
33⁄8
43⁄8
4
**Angular discharge dimensions.
CATALOG #37
www.centralfan.com
S
T
U
a**
b**
c**
d**
Shaft
Dia.
6
6
101⁄2
61⁄4
61⁄4
81⁄8
63⁄4
63⁄4
85⁄8
61⁄4
73⁄4
93⁄8
91⁄8
111⁄4
137⁄8
65⁄8
8
105⁄8
55⁄8
63⁄4
81⁄8
1
1
1
See figure above.
*D,. L and M are outside dimensions.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
35
GENERAL-PURPOSE
FUME EXHAUSTERS
Corrosion-Resistant resin construction for use in severe chemical environments
•
•
•
•
•
•
•
Fiberglass reinforced plastic construction
For severe corrosive fumes and aerosols
Efficient backwardly inclined wheel
Blower discharge rotatable
Standard CW wheel rotation is stock unit
Flanged outlet-slip inlet
250°F max. operating temperature
• WEATHER/DRIVE COVER STD.
STANDARD MOTORS ARE ODP.
SINGLE PHASE
Model
No.
C
D
E
GFE12 F
G
H
J
D
E
F
GFE15 G
H
J
K
E
F
G
GFE18 H
J
K
L
M
HP
1
⁄3
⁄2
⁄4
1
3
1
11⁄2
2
3
1
⁄2
3
⁄4
1
11⁄2
2
3
5
3
⁄4
1
11⁄2
2
3
5
71⁄2
10
CCW Rotation
(special order
for CCW units)
NOTE: Sizes 24, 30 & 36 are also available with several
week lead time.
(See page 37 for other plastic blowers.)
CW-UB (stock unit)
SEE PAGE 10 FOR SPECIAL MOTORS.
THREE PHASE
@
1
⁄2" S.P.
CFM
1 Speed
S
2 Speed
M
1 Speed
T
2 Speed
R
Blower
RPM
O.V.
FPM
X
X
X
X
X
X
X
X
X
X
–
–
–
–
X
X
X
X
X
X
X
–
X
X
–
–
–
–
1846
2197
2560
2925
3315
3506
3506
1600
1700
2400
2800
3200
3400
–0
1360
1700
2040
2300
2720
2890
1020
1400
1800
2100
2500
2800
765
1125
1530
1825
2300
2650
2890
850
1275
1600
2100
2450
2720
X
X
X
X
X
X
X
X
X
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
–
–
–
1550
1820
2090
2285
2500
2950
3195
1400
1700
2000
2200
2400
3000
3200
1750
2150
2450
2850
3200
3750
1400
1806
2125
2600
2900
3550
4128
1050
1525
1875
2400
2800
3300
3870
645
1200
1550
2100
2500
3100
3612
X
X
X
X
X
X
X
–
X
X
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
1220
1350
1575
1715
1975
2385
2638
2638
1600
1900
2300
2500
2900
3600
4000
–0
3150
3600
4300
4800
5600
6900
2500
3000
3800
4400
5100
6500
7680
1950
2500
3300
4000
4800
6200
7300
(See page 10 for other motors.)
Optional set of vibration isolators available.
1
⁄2
Static Pressure - inches of water
1
11⁄2
2
3
(10" S.P. Max.)
5
6
Approx.
Ship
Wt.
3800RPM Max @ 70°F
150
4
850
1200
1700
2150
2550
800
1350
1750
2210
950
1400
2040
1100
1700
220
3315 RPM Max. @ 70°F
950
1600
2050
2700
3354
1100
1600
2400
3096
1100
1950
2838
200
600
1550
2322
260
2900 RPM Max. @ 70°F
1920
2880
3500
4400
5850
7000
7680
1900
2650
3750
5150
6450
7296
1800
3000
4600
5900
6912
2300
4000
5400
6528
290
3400
4650
6144
350
(X) Available models
( )
SLIP
INLET
Tolerance ±1⁄8"
O.D. of inlet collar. Slip inlet only
36
Size
A•
B•
C*
D
12
15
18
91⁄8
111⁄8
135⁄8
133⁄4
167⁄8
203⁄4
13
16
191⁄2
341⁄8
385⁄8
413⁄4
E
81⁄2
91⁄2
103⁄4
•Inside dimensions
*Outside dimensions
F
G
H
J
K
L
M
N
Q
25
28
293⁄8
151⁄2
171⁄2
211⁄4
141⁄4
171⁄8
203⁄8
93⁄4
12
135⁄8
12
145⁄8
16
121⁄4
145⁄8
173⁄8
131⁄8
161⁄8
191⁄2
321⁄2
361⁄2
383⁄4
53⁄4
63⁄4
81⁄4
Shaft
Dia.
Base
holes
Bare
fan
weight
Open
TE
135
170
240
184T
215T
215T
184T
215T
215T
Size
R
S
T
V
W
a
b
c
d
12
15
18
67⁄8
87⁄8
93⁄4
163⁄8
173⁄8
173⁄8
73⁄8
87⁄8
93⁄8
61⁄2
8
81⁄4
8
91⁄2
101⁄4
131⁄2
151⁄2
18
181⁄8
211⁄4
251⁄8
12
14
165⁄8
165⁄8
193⁄4
233⁄4
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
13⁄16
17⁄16
111⁄16
5
⁄8
5
⁄8
5
⁄8
Maximum
motor frame
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Lab Blowers
DIRECT DRIVE
SEE PP. 36, 38 FOR FRP BELT DRIVEN BLOWERS AND A
BRIEF LISTING OF SOME CORROSIVE VAPORS AND
PROTECTIVE COATINGS FOR METALS.
CCW-UB
Model AA, A
Lab blowers for corrosion resistance where metal blowers with or without protective coatings prove unsatisfactory.
Standard motors are ODP and not exposed to ducted fumes through blower. Max. temp. - 140°F.
Model AA - Polypropylene wheel and PVC housing CCW-UB or CCW-TH
Model A - Polypropylene wheel and FRP housing CCW rotation - any disch.
NOTE: When strong oxidizing acids (nitric, sulfuric, chronic) are present use Model A with PVC wheel
PVC wheel is not suitable when vapor phase solvents are present, however.
Model
AA
A
HP
1
⁄6
⁄3
1
RPM
1725
1725
*1Phase
1 SPD 2 SPD
S
M
X
X
3 Phase
Motor
T
Cover
0
X
X
X
X
250
1100
X
X
DO NOT EXPOSE
THESE BLOWERS TO
PERCHLORIC ACID.
Shp.
CFM @ S.P.
1
⁄2
1
11⁄2
Wt. Lbs.
180
995
800
500
30
50
1
⁄4
225
1025
(X) Available models
*1Ø X.P. models available.
Dimensions
INLET
OUTLET
Model
A, in.
B, in.
C, in.
D, in.
E, in.
F, in.
G, in.
J, in.
K, in.
AA
A
55⁄8
91⁄2
65⁄8
71⁄4
33⁄4
41⁄2
51⁄2
8
9
101⁄2
7
71⁄4
131⁄2
171⁄4
11
151⁄8
41⁄2
8
Belt Drive Industrial PVC Blowers
Corrosion Resistant Radial Blade Blower
See page 38 for summary
of chemical activity
*NOTE: SPECIFY
CHEMICAL SUBSTANCE
& OPERATING TEMP.
AMCA CERTIFIED
SOLID POLYVINYL CHLORIDE HOUSING
•
•
•
•
•
•
•
Clockwise Rotation
Upblast Discharge
ARR. #9
100% corrosion Resistant to most inorganic chemicals*
Non-flammable…Self extinguishing
Operation to 150°F
Electrical Insulator
Drain
Steel Reinforced Wheel
Belt and shaft guard standard
See p. 36 for FRP blowers
BELT DRIVE WITH TEFC MOTOR*
Model
No.
HP
1
⁄3
⁄2
3
⁄4
C
D
PVC10 E
F
G
1
11⁄2
E
F
PVC14 G
H
J
1
11⁄2
2
3
F
G
PVC17 H
J
K
1
11⁄2
2
3
5
Wheel
Dia.
101⁄2
1
3
⁄4
O.V =
CFM
0.196
14
O.V. =
CFM
0.349
171⁄2
O.V. =
CFM
0.545
Blwr.
RPM
@ 1"
1
3
Phase Phase
S
T*
DIMENSIONS
CFM
Static Pressure (inches water)
1
2
3
4
5
6
400
550
700
800
950
300
450
600
700
850
200
350
500
650
800
250
450
550
750
350
500
650
7
Approx.
Ship
Wt.
Lbs.
1829
2157
2390
2632
3013
X
X
X
X
X
X
X
X
X
X
500
650
750
850
1000
1510
1660
1910
2068
2393
X
X
X
X
–
X
X
X
X
X
1050
1200
1450
1600
1900
900 700 500
1050 900 700 550 400
1300 1150 1000 850 700 550
1450 1350 1200 1050 950 800
1750 1650 1550 1400 1300 1000
220
1175
1225
1442
1625
1709
X
X
X
–
–
X
X
X
X
X
1550
1850
2100
2450
2600
1250
1600
1850
2250
2600
260
*See p. 10 for special motors including 2-speed
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
(X) Available models
900
1350
1600
2050
2600
600
1050 800
1350 1100 900 650
1850 1650 1400 1200
2500 2300 2100 1900
175
10
A
B
C
D O.D.
E
F
G
J
K O.D.
L
M
N
P
R Max.
S Max.
T
V
1
10 ⁄2
91⁄16
815⁄16
6
4
11
14
17
6
75⁄8
123⁄4
133⁄4
15
181⁄2
141⁄2
93⁄4
13⁄16
Model
14
1
14 ⁄4
12
1015⁄16
8
5
14
16
18
8
99⁄16
143⁄4
16
171⁄4
231⁄2
165⁄16
121⁄2
13⁄16
17
171⁄4
1415⁄16
135⁄8
10
6
17
17
19
10
111⁄8
153⁄4
191⁄2
203⁄4
26
183⁄4
151⁄2
17⁄16
Vibration isolators available
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
37
Caution: Use these data as a guide only at 70°F.
Consult the chemical mfr. for complete data.
CHEMICAL RESISTANCE OF
POLYVINYL CHLORIDE (PVC) & VINYL ESTER (FRP)
PVC provides FAIR-EXCELLENT protection to base metals exposed
to the following chemicals at room temperature:
Acetic acid (dilute)
Alcohol-methyl ethyl
Aluminum chloride
o Aluminum flouride
Aluminum hydroxide
Aluminum nitrate
Aluminum sulphate
Alum
Ammonia gas (Dry)
Ammonium chloride
Ammonium carbonate
o Ammonium hydroxide
Ammonium nitrate
Ammonium sulphate
•
•
•
•
•
•
•
•
•
•
Aqua regia
Barium carbonate
Beer
Benzoic acid
Calcium carbonate
Calcium chloride
Calcium nitrate
Calcium sulphate
Caustic
Chlorine
Chromic acid
Citric acid
Copper sulphate
Crude oil
Ethyl alcohol
Does not actively corrode bare aluminum
•
Ethylene glycol
Ferric chloride
Ferric nitrate
Ferric sulphate
o Flourine
o Formaldehyde
o Hydrochloric acid
Hydrogen peroxide
Hydrogen sulphide
Kerosene
Lead acetate
Magnesium carbonate
Magnesium chloride
Magnesium sulphate
•
•
•
•
•
•
•
•
•
•
•
•
•
Mineral oil
Naptha
Nitric acid (dilute)
Nitrous oxide
Oxygen
Perchloric acid (dilute)
Phosphoric acid
Photo solutions
Plating solutions
Propane
o Potassium hydroxide
Soda ash
Sodium chloride
Sodium cyanide
Sodium hydroxide
•
•
•
Sodium nitrate
Sodium sulphate
Stannous chloride
Sulphuric acid (dilute)
Tannic acid
Trisodium phos.
Urea
Water-salt
Zinc chloride
Zinc sulphate
o Will attack glass in FRP or Vinyl Ester
PVC is ATTACKED to the degree that it does NOT provide adequate protection
against the following chemicals at room temperature:
•
†
*
o*
*
*
*
*
o*
•
•
Acetone
Alcohol-Amyl, Benzyl
Ammonia (liquid)
Ammonium flouride
Ammonium phosphate
Amyl acetate
Amyl chloride
Aniline
•
•
*
*
•
*
*
*
•
Asphalt
Benzene
Bromine
Butane
Butyl acetate
Carbon tet.
Chloroform
Creosote
Esters
Does not actively corrode bare aluminum
o
o
*
•
*
*
*
*
o*
*
Ethers
Ethly acetate
Ethylene oxide
Formic acid
Gasoline
Heptane
Hexane
Hydrogen phosphide
Hydroflouric acid
Iodine
†Use 316 stainless
* Use PVDF
† Ketones
Methyl-Ethyl ketone
Methylene chloride
* Naphthalene
Nitric acid (anhyd.)
o* Phenol
Phosgene
* Propyl alcohol
* Sodium bisulphate
* Sodium nitrite
* Sodium peroxide
•
•
•
•
* Sodium acetate
* Sodium phosphate
* Stearic acid
Sulphate liquors
* Sulphur dioxide (wet)
* Toluene
o* Trichlorethylene
* Turpentine
Vinyl acetate
* Xylene
•
•
•
•
•
o Will attack glass in FRP or Vinyl Ester
Coatings Summary: (Central Fan will apply the following coatings.)
PVC-Sprayed, air dryed, multilayer coatings have good-to-excellent resistance to most acids, alkalies and marine exposures. Coatings are flexible,
fairly durable, and good to 150°F. The most commonly used protective coating. Unsuitable in most vapor phase organic solvents.
Eisenheiss-Synthetic polyester resin which is sprayed, air dryed in multilayer coatings providing tough impermeable coatings good to 150°F.
Chemical resistance similar to PVC except notably a slightly better performance when exposed to tricholorethylene, benzene, carbon tet., or gasoline. Does not perform well in hydrogen peroxide.
Heresite-A sprayed phenolic resin coating which provides good resistance to most common solvents, organic and inorganic acids. Not
recommended for caustics, alkalies, and oxidizing agents. Good to 120°F. Affords fair resistance to methyl ethyl ketone, methylene chloride,
trichlorethylene.
Epoxy-One of the most durable all-purpose coatings which withstands reasonable abrasion and most chemicals.
Baked epoxy-(Factory applied by Peerless on all blowers) effectively protects carbon steel surfaces from normal atmospheric conditions. Is attacked
by acids, alkalies, and certain solvents. Can provide effective undercoating. CENTRAL FAN DOES NOT APPLY BAKED EPOXY COATINGS.
NOTE: BECAUSE OF THE INHERENT FRAGILITY OF ALL COATINGS, NO EXPLICIT WARRANTY OF SERVICEABILITY CAN BE MADE.
BLOWERS: Rigid PVC has good all-around corrosion resistance and is usually the economic material of choice. However, PVC becomes brittle at sub-zero temperatures and loses its strength above 150°F. Thus, steel reinforcement is used in PVC blower wheels. Do not use FRP above 250°F, or PVDF above 180°F.
All are spark resistant (electric insulator). Graphite impregnation into FRP can make it conductive to control static electricity. UV radiation (direct sun) will
destroy polypropylene. Although slightly more in initial cost, FRP blowers prove to be more economical where the environment is severe and maximum durability is desired. Polyvinylidene (PVDF) will withstand inorganic acids and bases, organic acids, alcohols, aliphatic and aromatic hydrocarbons and halogenated solvents and halogens (except fluorine).
38
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Isolators for Vibration and Noise Control
The most effective vibration and noise control is obtained when the isolator deflects up to its maximum limit…without exceeding that maximum deflection.
For proper selection:
1. Equipment weight - greater deflection (up to max.) provides maximum isolation
2. Equipment RPM - lower than 1200RPM use springs for maximum isolation (Higher RPM’s use rubber regardless of substructure)
3. Equipment Location(a)Rigid sub-structure-use rubber or springs
(b)Flexible sub-structure-use springs (such as on upper levels of building)
Model
Isolator
Color
Cap
lbs.
A
RD
RD
RD
RD
RD
Blue
Red
Blue
Red
Black
35
70
135
240
375
.40
.40
.50
.50
.50
B
FDS-35
FDS-70
FDS-120
FDS-220
FDS-370
Blue
Green
Gray
Brown
Orange
35
70
120
220
370
C
FRS-35
FRS-70
FRS-120
FRS-220
FRS-375
Blue
Green
Gray
Brown
Orange
D
SL-35
SL-70
SL-120
SL-220
SL-370
Fig.
Max. Defl.
In.
Spring
O.D.
Dimensions (in.)
A
B
C
D
E
F
.–
.–
.–
.–
.–
1.75
1.75
2.37
2.37
2.37
3.13
3.13
3.87
3.87
3.87
.85
.85
1.25
1.25
1.25
5⁄
16
5⁄
16
3 ⁄8
3⁄
8
3⁄
8
1.25
1.25
1.75
1.75
1.75
2.37
2.37
3.00
3.00
3.00
.34
.34
.34
.34
.34
1.52
1.36
1.18
1.10
1.00
1.75
1.75
1.75
1.75
1.75
2.63
2.63
2.63
2.63
2.63
2.63
2.63
2.63
2.63
2.63
3.50
3.50
3.50
3.50
3.50
.62
.62
.62
.62
.62
3.88
3.88
3.88
3.88
3.88
3⁄
8
3⁄
8
3⁄
8
3⁄
8
3⁄
8
.–
.–
.–
.–
.–
35
70
120
220
370
1.52
1.36
1.18
1.10
1.00
1.75
1.75
1.75
1.75
1.75
3.0
3.0
3.0
3.0
3.0
4.75
4.75
4.75
4.75
4.75
5.0
5.0
5.0
5.0
5.0
.50
.50
.50
.50
.50
5.0
5.0
5.0
5.0
5.0
3.75
3.75
3.75
3.75
3.75
.44
.44
.44
.44
.44
Blue
Green
Gray
Brown
Orange
35
70
120
220
370
1.52
1.36
1.18
1.10
1.00
1.75
1.75
1.75
1.75
1.75
2.12
2.12
2.12
2.12
2.12
6.12
6.12
6.12
6.12
6.12
3.50
3.50
3.50
3.50
3.50
3⁄
8
3⁄
8
3⁄
8
3⁄
8
3⁄
8
4.00
4.00
4.00
4.00
4.00
5.63
5.63
5.63
5.63
5.63
.31
.31
.31
.31
.31
RHD-35
RHD-75
RHD-120
RHD-170
Blue
Red
Green
Black
35
75
120
170
.40
.40
.40
.50
.–
.–
.–
.–
2.25
2.25
2.25
3.00
2.0
2.0
2.0
2.25
3.0
3.0
3.0
4.5
.421
.421
.421
.656
1.37
1.37
1.37
1.87
.375
.375
.375
.625
.–
.–
.–
.–
F
SH-35
SH-70
SH-120
SH-220
SH-370
Blue
Green
Gray
Brown
Orange
35
70
120
220
370
1.52
1.36
1.18
1.10
1.00
1.75
1.75
1.75
1.75
1.75
3.69
3.69
3.69
3.69
3.69
2.25
2.25
2.25
2.25
2.25
5.25
5.25
5.25
5.25
5.25
.88
.88
.88
.88
.88
3.00
3.00
3.00
3.00
3.00
.–
.–
.–
.–
.–
.–
.–
.–
.–
.–
G
SRH-35
SRH-70
SRH-120
SRH-220
SRH-370
Blue
Green
Gray
Brown
Orange
35
70
120
220
370
1.55
1.42
1.29
1.30
1.33
1.75
1.75
1.75
1.75
1.75
3.69
3.69
3.69
3.69
3.69
2.25
2.25
2.25
2.25
2.25
7.38
7.38
7.38
7.38
7.38
.75
.75
.75
.75
.75
3.00
3.00
3.00
3.00
3.00
1.48
1.48
1.48
1.48
1.48
.–
.–
.–
.–
.–
H
ARS-30
ARS-70
(For VAV)
Boxes
30
70
.50
.50
.–
.–
4.75
4.75
2.19
2.19
.50
.50
.27
.27
.–
.–
.–
.–
.–
.–
E
35
70
135
240
375
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
G
39
Centrifugal Roof Exhausters
Direct Driven
• All aluminum construction - compact design
• A non-overloading, aluminum wheel
• Quiet, vibration free motor mountings
• Motor outside exhaust air stream, auto thermal, ODP
• Bird screen
• Disconnect switch
• Galvanized steel frame for strength
Roof
Model
HP
120v 1 Phase
3 Phase
1 Speed Var. Sp. 1 Speed
S
M
T
PRN80
2.0 Amps
1
X
X(v)
–
PRN100
3.0 Amps
1
X
X(v)
–
PRN110
3.0 Amps
1
⁄10
1750 RPM
120v 1Ø
XP Motor
SX†
12"
Ht.
Curb
Drop-in
Shutter
.
–
B9.
C1312
⁄6 HP
B12
C1512
B12
C1512
B16
.
C2012
B16
C2012
.
⁄10
⁄10
X
X(v)
–
PRN126
3.0 Amps
1
X
X(v)
–
PRN145
6.3 Amps
1
X
X(v)
–
⁄4
1
.
1
⁄6 HP
1
⁄4 HP
.
⁄2
1
⁄2 HP
RPM
Sones
@ 1⁄4
0
B
9
131⁄4
163⁄8
C
183⁄4
211⁄8
273⁄4
E
37⁄8
47⁄8
1
⁄8
3
⁄2
⁄4
1
328
248
*1550
5.8
4.0
3.0
770
650
520
430
690
550
410
270
610
450
210
520
280
380
11.3
7.6
4.7
1090
910
740
600
990
790
590
420
890
670
400
780
510
650
270
12.0
9.0
6.6
1760
1410
1140
1670 1560 1450 1320 1040
1290 1150 980 800 270
980 790 540 150
14.5
10.7
7.6
2540
2030
1640
2420 2300 2180 2060 1780 1440
1880 1730 1580 1400 920
1460 1270 1030 710
1300
1050
850
*1550
1300
1050
860
*1625
1300
1050
*1625
1300
1050
Shutter
O.D.
9
12
16
• 18 gauge galv. steel
• fiberglass insulation
• neoprene pad
• continuous welds
• sturdy shutter shelf
• self flashing
Standard height = 12"
(other heights available)
Curb
O.D.
I.D.
121⁄2
91⁄2
1
15 ⁄4
12
20
163⁄4
24
27
210
27
680
43
46
Dimensions
Curb
Model
No.
O.D.
I.D.
C1312
C1512
121⁄2
151⁄4
91⁄4
12
8
10
18
21
C1912
C2012
181⁄2
20
151⁄4
163⁄4
131⁄2
143⁄4
26
31
C2412
C2812
231⁄2
271⁄2
201⁄4
241⁄4
181⁄4
221⁄4
34
39
C3212
C3412
311⁄2
331⁄2
281⁄4
301⁄4
261⁄4
281⁄4
43
46
C3612
C3812
351⁄2
371⁄2
321⁄4
341⁄4
301⁄4
*
48
50
C4012
C4312
391⁄2
43
361⁄4
393⁄4
341⁄4
373⁄4
52
56
C4612
C4912
451⁄2
49
421⁄4
453⁄4
401⁄4
65
69
C5512
C6112
55
61
513⁄4
573⁄4
Ship
Wt.
M
*
*
*
* No shelf
CURB ADAPTERS**
Model
No.
Pitched curbs are special order.
CURB ADAPTERS
• Sturdy…weather tight.
• Continuous welds.
• 18 ga. galv. steel
Adapter permits equal (based on performance) fan
replacement without disturbing existing roof curb.
**Many other sizes not shown are in stock.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
3
⁄4
382
ROOF FAN CURBS AND ADAPTERS
40
1
⁄8
9.0
DIMENSIONS
A
131⁄2
16
21
1
*1550
*Maximum RPM shown obtained with the standard one speed motor. For all other RPMs add solid state speed controller
(v) Variable speed w/control. Chemical resistant coating available (X) Available models
† Because of 1725 RPM XP motor, the CFM shown will be increased proportionately.
Expl. Proof motors are single speed only. Disc. sw. extra (Not installed) See p. 10
Model
PRN 80
PRN 100, 110
PRN 126, 145
Ship
Wt.
lbs.
(Fan)
CFM
Static Press. (in. water)
CATALOG #37
www.centralfan.com
Dimensions
A
B
CA 1815
CA 1855
CA 1915
18
181⁄2
19
151⁄2
151⁄2
151⁄2
CA 2015
CA 2118
201⁄2
21
151⁄2
181⁄2
CA 2218
CA 2220
22
22
181⁄2
201⁄2
CA 2515
CA 2518
CA 2520
25
25
25
151⁄2
181⁄2
201⁄2
CA 2820
CA 2823
28
28
201⁄2
231⁄2
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
75
80
CENTRIFUGAL EXHAUSTERS
FEATURES
• New, quiet, high efficiency PV models
• Heavy gauge aluminum housings
• Non-overloading aluminum impeller
• Performance certified to 2" static press.
• Prelubricated, sealed bearings
• Motor and drive out of exhaust stream
• Bird screen
• Welded 18 ga. galv. insulated curb std.
curb ht. = 12" See p. 40 for curb detail.
ALUMINUM IMPELLER
SINGLE PHASE*
Model
No.
PV75 A
B
A
PV100 B
C
A
PV120 B
C
B
PV135 C
D
C
PV150 D
E
B
C
PV165 D
E
F
D
E
PV180
F
G
D
E
PV200 F
G
H
D
E
PV240 F
G
H
HP
1
⁄6
1
⁄4
1
⁄6
1
⁄4
1
⁄3
1
⁄6
1
⁄4
1
⁄3
1
⁄4
1
⁄3
1
⁄2
1
⁄3
1
⁄2
3
⁄4
1
⁄14
⁄3
1
⁄2
3
⁄4
1
1
⁄2
3
⁄4
1
11⁄2
1
⁄2
3
⁄4
1
1
1 ⁄2
2
1
⁄2
3
⁄4
1
1
1 ⁄2
2
3
⁄4
3 PHASE
1 Speed 2 Speed 1 Speed
S
M
T
BELT DRIVEN
CFM
2 Speed
R
12"
Curb Shutter
Static Pressure (inches H2O)
1
1
3
1
⁄4
⁄2
⁄4
Fan
RPM
Sones
@ 1⁄4"
0
8.6
10.7
830
940
730
860
620
770
480
660
140
530
11⁄2
X
X
–
X
–
X
–
–
C2012
B16
1669
1909
X
X
X
–
X
X
–
X
X
–
–
–
C2012
B16
1625
1869
1993
9.1
12.5
14.6
1200
1400
1500
1100
1300
1400
850
1200
1300
550
1000
1200
300
700
1100
600
X
X
X
–
X
X
–
X
X
–
–
–
C2012
1300
1580
1750
7.8
10.9
13.4
1440
1750
1940
1270
1610
1810
1050
1450
1680
730
1270
1520
1020
1345
750
X
X
X
X
X
X
X
X
X
–
–
X
C2012
B16
1480
1616
1823
11.7
13.6
17.1
2000
2200
2500
1800
2000
2300
1600
1800
2200
1200
1600
2000
900
1300
1800
X
X
X
X
X
X
X
X
X
–
X
X
B20
1185
1365
1555
11.2
14.1
17.6
2500
2870
3270
2240
2650
3080
1950
2400
2870
1610
2130
2660
1170
1830
2410
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
X
B20
975
1074
1244
1456
1584
9.1
11.4
15.7
19.2
21
2700
3000
3400
3900
4200
2200
2500
3000
3600
3900
1700
2100
2700
3300
3700
1100
1600
2300
2900
3400
X
X
X
X
X
X
X
–
X
X
X
X
X
X
X
X
B24
830
940
1050
1185
11.7
15.6
19.7
22.0
4340
4920
5490
6200
3800
4440
5060
5800
3080
3920
4600
5430
1930
3100
4030
5010
2020
3250
4440
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
B24
798
904
1000
1133
1250
10.9
13.9
16.7
20
23
4500
5100
5700
6500
7100
3900
4600
5200
6000
6700
2900
3700
4600
5500
6300
1900
3000
3800
5000
5800
1400
2100
3200
4200
5200
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
657
758
856
977
1033
10.4
13.7
17
21
23
5900
6700
7400
8500
8800
4800
5800
6700
7800
8300
3400
4600
5600
6900
7800
2200
3300
4500
6100
7200
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
583
646
749
814
834
15.5
18
21
24
25
8800
9800
11000
12000
–m
7400 5900
8400 7000
10000 8800
11000 10100
11300 10600
4000
5500
7400
9000
9900
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
443
515
571
658
731
13
16.1
18.7
23
27
12200
14000
15500
17600
19000
10000
12100
13700
16100
18100
E
F
PV300 G
H
J
1
1
1 ⁄2
2
3
X
X
X
X
X
F
G
PV365 H
J
K
1
11⁄2
2
3
5
X
X
X
X
–
C2412
C2412
C2812
C2812
C3412
C4012
C4612
B16
B30
B36
B42
2
Ship
wt.
lbs.
85
85
90
93
1300
400
97
111
730
1840
119
112
1800
2600
3200
1600
2400
1600
130
206
2870
227
207
3000
3800
2100
226
254
2400
3300
5000
6500
2600
4600
1000
274
360
3400
6000
7800
9200
5200
7500
3900
418
7500 4600 2700
10000 8200 5200
12000 10000 7900
14600 13000 11400 7300
17200 16200 15300 12800 10000
422
487
*Single phase 120v or 230v. See p. 10 for 208v 1Ø and other special motors. See p. 10 for other special motors. (X) Available models
Motor controls p.10
DIMENSIONS
12" CURB
SHUTTER
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Model
A
B
C
ID
OD
PV 75
PV 100
21
21
231⁄2
1
23 ⁄2
233⁄4
3
23 ⁄4
2
2
D
20
20
163⁄4
3
16 ⁄4
16
16
PV 120
PV 135
21
21
263⁄4
263⁄4
291⁄2
291⁄2
2
2
20
20
163⁄4
163⁄4
16
16
PV 150
PV 165
24
24
31
31
35
35
2
2
231⁄2
231⁄2
20 ⁄4
201⁄4
20
20
PV 180
PV 200
28
28
351⁄2
1
35 ⁄2
391⁄2
1
39 ⁄2
2
2
271⁄2
1
27 ⁄2
241⁄4
1
24 ⁄4
24
24
PV 240
34
381⁄2
461⁄2
2
331⁄2
301⁄4
30
PV 300
40
37
53
2
391⁄2
361⁄4
36
PV 365
46
46
64
2
45
CATALOG #37
www.centralfan.com
OD
1
⁄2
1
1
42
⁄4
42
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
41
MEETS NATIONAL FIRE
PROTECTION ASSOCIATION
STANDARD NFPA 96
LISTED CLASSIFICATION
YZHW
SUBJECT 762
UL
®
BELT DRIVE
Centrifugal Upblast Ventilators for
Commercial Kitchen Exhaust Systems
BELT DRIVE
Roof and Wall Mounting
• UL LISTED • NFPA 96 COMPLIANCE • AMCA CERTIFIED AIR & SOUND• • GREASE COLLECTOR & DRAIN
• BIRD SCREEN • ALUMINUM WHEEL & HOUSING • PRELUBRICATED SEALED BEARINGS • EXTERNAL WIRING BOX
IF NFPA 96 COMPLIANCE REQUIRED SEE NOTE BELOW
Model
No.
HP
1
⁄4
⁄3
1
⁄2
3
⁄4
C 1⁄3
D 1⁄2
PNU165RG E 3⁄4
B
C
PNU135RG D
E
1 PHASE‡
3 PHASE
1 Speed 2 Speed 1 Speed 2 Speed
S
M
T
R
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
F 1
G 11⁄2
X
X
X
X
X
X
X
X
X
–m
X
X
X
X
X
–
X
X
X
X
D 1⁄2
E 3⁄4
PNU200RG F 1
G 11⁄2
H 2
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
1
3
⁄4
E
F
PNU245RG G
H
J
1
11⁄2
2
3
X
X
X
X
X
F
G
PNU300RG H
Roof J
Only K
1
11⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
G
H
PNU365RG J
Roof K
Only L
11⁄2
2
3
5
71⁄2
X
X
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
‡1 phase 120v or 230v.
Curb
12"
Optional Fan
18" Shutter RPM
2012
2230
2565
2950
1774
2016
2380
2790
1527
1788
2187
2630
1282
1578
1992
2455
B24
1120
1287
1480
1632
1771
13.8
17.0
22.0
25.0
27.0
2936
3377
3881
4400
4708
2570
3064
3608
4100
4487
2196
2728
3323
3750
4277
1810
2417
3034
3390
4071
2063
2766
3050
3866
B24
948
1085
1194
1360
1496
14.0
17.2
21.0
26.0
28.0
4414
5052
5560
6328
6966
3746
4406
4924
5698
6332
3285
4064
4666
5548
6263
2664
3574
4216
5145
5897
1724
2994
3742
4752
5532
B30
725
797
913
1005
1150
15.3
17.5
21.0
24.0
27.0
5890
6474
7417
8164
9342
5188
5840
6863
7660
8900
4448
5185
6297
7150
8460
3588
4457
5706
6632
8010
B36
596
692
760
879
987
14.5
17.3
21.0
26.0
31.0
9541
10652
11615
13225
14622
7975
9515
10625
12450
14131
6373
8215
9575
11515
13619
5078
6910
8480
10225
13055
490
548
633
757
813
15.2
17.0
23.0
31.0
35.0
13750
15022
17503
20500
21692
11810
13500
15925
19390
20967
9914
11640
14350
18175
20210
7700
9575
12410
16750
19378
C2818*
C2812
C2818*
C3412
C3418*
C4012
C4018*
C4612
B42
C4618*
See page 10 for special motors and disconnect switches
*NFPA 96 Requires:
• Min. curb height 18" (disch. > 40" above roof)
Fan-curb hinge assembly to allow cleaning fan and duct
500 FPM min. duct velocity
External grease trough
Prohibits duct damper (shutter)
A
B
273⁄8
PNU165
PNU200
PNU245
28
28
34
26
1
31 ⁄2
1
36 ⁄4
1
Curb
1
⁄6-3⁄4
1-2
3
5
71⁄2-10
Shutter
Wall Flange
C
D
OD
ID
OD
OD
Flange
221⁄8
231⁄2
201⁄4
20
231⁄2
271⁄2
38
3
39 ⁄4
3
44 ⁄4
3
22 ⁄2
3
28 ⁄4
1
31 ⁄2
1
27 ⁄2
1
27 ⁄2
1
33 ⁄2
1
1
24 ⁄4
1
24 ⁄4
24
24
1
311⁄2
1
311⁄2
1
27 ⁄2
27 ⁄2
1
30
33 ⁄2
371⁄2
1
30 ⁄4
PNU300
40
42 ⁄2
55 ⁄8
34 ⁄4
39 ⁄2
36 ⁄4
36
–
–
PNU365
46
46
66
411⁄4
451⁄2
421⁄4
42
–
–
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Ship
Wt.
120
1320
1960
1500
135
180
2066
2600
3300
2700
215
240
2457
3878
4807
2645
3918
275
290
3510
5060
6074
7556
2289
4780
6570
5346
340
415
5701
7125
9580
12444
8196
11262
9904
530
510
8473
10885
15479
18476
12450
16730
Single Phase
HP
331⁄2
1
2
13815
620
Motor Disconnect Switches
(PNU245 max. size for wall mtg.)
#Requires smaller O.D. curb
(PNU245 max. size for hinge kit)
1
882
1333
1810
2290
11⁄2
(X) Available models
ACCESSORIES:
Curb hinge kit#
External grease trough
Wall mount flange
Dimensions
24
⁄4
14.5
16.2
17.5
21.0
C2812
Model
0
1
1400
1550
1780
2050
C2418*
PNU135
CFM
Static Pressure (in. H2O)
3
⁄2
⁄4
1
1
B20
C2412
NOTE:
•
•
•
•
Sones
@ 1⁄4"
CATALOG #37
www.centralfan.com
Three Phase
1 Sp.
2 Sp.
1 Sp.
X
X
X
–
–
X
X
–
–
–
X
X
X
X
X*
*460V-550V only
2 Sp.
X
X
X
X
–
(X) Available
WALL MOUNT
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
43
Belt Drive
Centrifugal Upblast Ventilators
Roof and Wall Mounting
•
•
•
•
•
•
•
•
BELT DRIVE
Suitable for mounting on roof or wall applications
Exhausts air containing odors, fumes, grease etc.
Integral trough and drain allow for drainage of liquids
Bird screen
Pre-lubricated sealed ball bearings
Motor and drive assembly out of exhaust air
Heavy gauge, aluminum construction - non-overloading wheel
Welded 18 ga. galv. Insulated curb (std. 12" high) Special curbs page 40.
1 PHASE*
Model
No.
B
C
PNU8RF D
E
HP
1
⁄4
⁄3
1
⁄2
3
⁄4
1
⁄4
1
⁄3
1
⁄2
3
⁄4
1
⁄3
1
⁄2
3
⁄4
3 PHASE
1 Speed 2 Speed 1 Speed 2 Speed
S
M
T
R
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
–
X
X
C
D
PNU165RF E
F 1
G 11⁄2
X
X
X
X
X
X
X
X
X
–
X
X
X
X
X
–
X
X
X
X
D 1⁄2
E 3⁄4
PNU200RF F 1
G 11⁄2
H 2
X
X
X
X
X
X
X
X
–
–
X
X
X
X
X
X
X
X
X
X
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
B
C
PNU135RF D
E
1
3
⁄4
E
F
PNU245RF G
H
J
1
11⁄2
2
3
X
X
X
X
X
F
G
PNU300RF H
Roof J
Only K
1
11⁄2
2
3
5
X
X
X
X
–
X
–
–
–
–
X
X
X
X
X
X
X
X
X
X
G
H
PNU365RF J
Roof K
Only L
11⁄2
2
3
5
71⁄2
X
X
X
–
–
–
–
–
–
–
X
X
X
X
X
X
X
X
X
X
*1 phase 120v or 230v.
(X) Available models
12"
Curb
CFM
Static Pressure (in. H2O)
1
3
⁄2
⁄4
1
11⁄2
2
485
540
640
750
440
500
600
720
390
450
525
690
350
415
525
660
225
330
450
590
200
375
530
2012
2230
2585
2950
1774
2016
2380
2790
1527
1788
2187
2630
1282
1578
1992
2455
882
1333
1810
2290
13.8
17.0
22.0
25.0
27.0
2936
3377
3881
4400
4708
2570
3064
3608
4100
4487
2196
2728
3323
3750
4277
1810
2417
3034
3390
4071
2063
2766
3050
3866
948
1085
1194
1360
1496
14.0
17.2
18.2
21.0
24.0
4414
5052
5560
6328
6332
3746
4406
4924
5698
6615
3285
4064
4666
5548
6263
2664
3574
4216
5145
5897
1724
2994
3742
4752
5532
B30
725
797
913
1005
1150
15.3
17.5
21.0
24.0
27.0
5890
6474
7417
8164
9342
5188
5840
6863
7660
8900
4448
5185
6297
7150
8460
3588
4457
5706
6632
8010
3510
5060
6074
7556
B36
596
692
760
879
987
14.5
17.3
21.0
26.0
31.0
9541
10652
11615
13225
14622
7975
9515
10625
12450
14131
6373
8215
9575
11515
13619
5078
6910
8480
10225
13055
490
548
633
757
813
15.2
17.0
23.0
31.0
35.0
13750
15022
17503
20500
21692
11810
13500
15925
19390
20967
9914
11640
14350
18175
20210
7700
9575
12410
16750
19378
Fan
RPM
Sones
@ 1⁄4"
0
B20
2103
2315
2705
3131
11.1
12.6
16.1
19.9
530
600
700
800
B20
1400
1550
1780
2050
14.5
16.2
17.5
21.0
B24
1120
1287
1480
1632
1771
B24
Shutter
C2412
C2412
C2812
C2812
C3412
C4012
C4612
B42
1
⁄4
See page 10 for special motors
44
Dimensions
A
B
C
24
273⁄8 331⁄2
24
273⁄8 331⁄2
28
26
38
28
311⁄2
393⁄4
1
34
36 ⁄4
443⁄4
1
40
42 ⁄2
553⁄8
46
46
66
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
D
221⁄8
221⁄8
221⁄2
283⁄4
311⁄2
341⁄4
411⁄4
Curb
OD
ID
231⁄2
201⁄4
231⁄2
201⁄4
1
27 ⁄2
241⁄4
1
27 ⁄2
241⁄4
1
33 ⁄2
301⁄4
1
39 ⁄2
361⁄4
1
45 ⁄2
421⁄4
Ship
Wt.
120
140
120
1320
1960
1500
135
180
2066
2600
3300
2700
215
240
2457
3878
4807
2645
3918
275
290
2289
4780
6570
5346
340
415
5701
7125
9580
12444
8196
11262
9904
530
510
8473
10885
15479
18476
12450
16730
13815
620
Motor Disconnect Switches
ACCESSORIES:
Curb hinge kit (Requires smaller O.D. curb. PNU245 max. size.)
External grease trough
Wall mount flange (PNU245 max. size for wall mtg.)
Chemical resistant coating
Model
PNU8
PNU135
PNU165
PNU200
PNU245
PNU300
PNU365
KITCHEN EXHAUST FANS
NFPA 96 AND UL YZHW #762
PAGES 42,43
Shutter
OD
20
20
24
24
30
36
42
CATALOG #37
www.centralfan.com
Wall Flange
OD
Flange
231⁄2
271⁄2
1
23 ⁄2
271⁄2
1
27 ⁄2
311⁄2
1
27 ⁄2
311⁄2
1
33 ⁄2
371⁄2
–
–
–
–
Single Phase Three Phase
HP
1 Sp.
2 Sp.
⁄6-3⁄4
X
X
X
–
–
X
X
–
–
–
1
1-2
3
5
71⁄2-10
1 Sp. 2 Sp.
*460V-550V only
WALL MOUNT
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
X
X
X
X
X*
X
X
X
X
–
ROOF AIR SUPPLY
SIDE INTAKE
CONSERVES ENERGY IN MAKE-UP AIR SYSTEMS
• Can be located on roof directly over kitchen exhaust hoods, reducing
cost of electrical hook-up, expensive insulated interior ducts and fittings.
• May also reduce the number of roof penetrations required.
FEATURES
• Easy on site addition of duct extension* to meet code requirements
for supply and exhaust separation
• Permanent filters serviceable from exterior of unit.
• Blower equipped with ball bearings with an operating temperature
range of -65° to +250°F.
• Latched top cover provides easy access to blower, motor and
drives.
• Weather resistant finish of enamel paint on galvanized steel.
• Permanent aluminum mesh filters mounted in intake hood (except
Model SIS-20)
• SIS-20 has large drawer type filter section with screened inlet (not illustrated).
• Large filter surface areas for efficient filtering (Intake velocities
do not exceed 600 FPM)
*Intake duct not supplied
Model
No.
B
C
D
SIS9
E
F
G
HP
1
⁄4
⁄3
⁄2
3
⁄4
1
1
1
1
1 ⁄2
1
⁄3
C
1
⁄2
D
3
SIS10 E
⁄4
F 1
1
G 1 ⁄2
1
D
⁄2
3
E
⁄4
SIS12 F 1
1
G 1 ⁄2
H 2
3
⁄4
E
F 1
1
SIS15 G 1 ⁄2
H 2
J 3
F 1
1
G 1 ⁄2
SIS18 H 2
J 3
K 5
H 2
J 3
SIS20 K 51
L 7 ⁄2
M 10
SINGLE SPEED*
12"
1 Phase 3 Phase
S*
T
Roof
Curb
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
–
X
X
–
–
–
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Static Pressure (inches water)°°
Supply°
Shutter
1
1
⁄4"
3
⁄2"
⁄4"
1
1 ⁄2"
1"
CFM
RPM
HP
RPM
HP
RPM
HP
RPM
C2412 BS18
600
800
1200
1600
1800
2000
577
622
746
901
985
1072
.06
.10
.23
.46
.63
.84
785
809
899
1022
1092
1168
.11
.15
.30
.56
.73
.95
964
968
1032
1139
1200
1265
.16
.21
.38
.66
.85
1.08
1115
1108
1155
1295
1302
1362
C2812 BS22
800
1200
1600
2000
2400
525
600
701
810
925
.08
.18
.33
.58
.93
704
754
828
923
1029
.14
.26
.45
.71
1.09
874
881
945
1023
1118
.20
.34
.55
.85
1.25
C3212 BS26
1600
2000
2400
2800
3000
3400
497
551
614
685
721
792
.21
.34
.52
.77
.92
1.28
633
671
721
775
805
870
.31
.45
.66
.93
1.10
1.48
767
778
816
865
891
945
C3612 BS30
2000
2500
3000
3500
4000
4500
5000
384
409
444
486
533
584
637
.23
.36
.54
.78
1.09
1.50
2.01
508
527
521
577
610
649
692
.37
.53
.73
.99
1.32
1.74
2.25
C3612 BS30
4000
4500
5000
5500
6000
6500
7000
7500
378
402
428
456
485
515
546
578
.65
.85
1.11
1.41
1.77
2.18
2.67
3.22
464
484
505
527
551
576
602
630
C4312 BS37
5000
6000
7000
8000
9000
10000
11000
12000
374
419
464
512
562
614
667
720
.85
1.31
1.90
2.69
3.68
4.91
6.47
8.20
443
482
529
571
616
662
709
758
HP
1
2"
2 ⁄2"
RPM
HP
Ship
Wt.
RPM
HP
RPM
HP
.23
.28
.47
.77
.97
1.21
1346
1367
1377
1439
1483
1536
.36
.45
.65
.98
1.20
1.47
1573
1570
1618
1652
.62
.84
1.21
1.45
1743
1752
1784
.79
1.06
1.46
1013
997
1051
1118
1201
.27
.42
.66
.99
1.42
1299
1231
1234
1293
.41
.60
.87
1.25
1404
1433
1408
.56
.80
1.10
1555
1600
1584
.72
1.00
1.34
.42
.58
.80
1.10
1.27
1.68
884
886
905
945
969
1020
.55
.72
.95
1.26
1.45
1.88
1075
1083
1085
1099
1114
.82
1.04
1.29
1.61
1.81
1233
1245
1252
1.11
1.37
1.67
1371
1386
1.41
1.72
622
623
643
667
691
720
755
.37
.70
.94
1.24
1.58
2.01
2.55
721
717
723
744
769
792
819
.73
.88
1.14
1.48
1.87
2.32
2.86
871
883
878
881
898
922
1.10
1.35
1.58
1.94
2.41
2.95
988
1014
1019
1014
1017
1.46
1.84
2.15
2.47
2.95
1088
1121
1138
1.81
2.30
2.74
200
.93
1.15
1.40
1.72
2.10
2.54
3.05
3.63
537
553
572
592
669
635
658
682
1.22
1.49
1.78
2.10
2.47
2.92
3.44
4.05
620
617
632
650
669
690
711
733
1.60
1.80
2.14
2.52
2.92
3.37
3.89
4.49
780
774
757
756
770
787
806
2.57
2.85
2.97
3.29
3.79
4.36
4.94
893
900
899
883
870
3.29
3.83
4.28
4.72
4.72
987
999
3.97
4.63
345
1.17
1.69
2.36
3.21
4.26
5.53
7.06
8.88
513
539
576
618
663
708
753
799
1.53
2.08
2.80
3.72
4.85
6.19
7.78
9.64
581
597
625
662
704
748
793
1.92
2.50
3.26
4.23
5.41
6.84
8.51
701
710
724
748
780
818
861
3.66
3.45
4.25
5.29
6.57
8.10
9.90
797
812
821
835
857
887
3.66
4.50
5.38
6.45
7.79
9.40
879
899
910
920
934
4.50
5.55
6.60
7.72
9.10
84
110
104
130
140
173
267
387
670
800
*Single phase 120v or 230v
Damper spring return. (See p. 8.)
°Supply damper is mounted in horizontal plane; opens downward with airflow.
See page 10 for special motors
All dampers are square. Model No. indicates size - nominal size minus 1⁄8".
°°Static pressure reduction on blowers designed for higher pressure could result in motor overload (X) Available models
Curb Cap
Model
SIS9
SIS10
SIS12
SIS15
SIS18
SIS20
Dimensions
A*
B
D
E
F
G
H
L
243⁄8
283⁄8
323⁄8
363⁄8
363⁄8
443⁄8
193⁄8
213⁄8
245⁄8
283⁄8
421⁄2
49
101⁄4
113⁄8
137⁄16
157⁄8
187⁄8
243⁄4
113⁄16
131⁄8
155⁄8
185⁄8
217⁄8
243⁄4
69⁄32
75⁄8
81⁄16
81⁄2
71⁄4
913⁄16
71⁄16
81⁄2
93⁄8
73⁄4
6
147⁄16
71⁄16
81⁄2
93⁄8
125⁄16
111⁄2
53⁄16
191⁄4
201⁄2
253⁄8
313⁄16
355⁄8
385⁄8
M
169⁄16
189⁄16
219⁄16
2513⁄16
3211⁄16
359⁄16
Z
211⁄4
253⁄4
303⁄4
331⁄2
401⁄4
451⁄2
*Inside dimension
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
45
Exhaust Relief or Fresh Air Intake
Gravity Trimline Ventilators
LOW SILHOUETTE
• Hood perimeter opening-to-throat area = 2:1
• Inlet velocity at hood opening less than 650 FPM
to prevent snow intake
• Welded, heavy (.080") aluminum
• Bird screen
• Optional powered fan supply or exhaust
OUTSIDE DIMENSION
Dimensions
Vent
Model
12"
High Curb
Intake
115v
Motorized
Shutter
A°
C
E
O.D.
I.D.
Vent
Ship
Wt.
IV 1212
IV 1616
IV 2020
C2012
C2412
C2812
BM15L
BM20L
BM24L
B15
B20
B24
1300
2310
3500
1.0
1.8
2.8
20
24
28
21
28
35
7
9
11
181⁄2
231⁄2
271⁄2
151⁄4
201⁄4
241⁄4
37
46
74
IV 2424
IV 3030
IV 3636
C3212
C3612
C4312
BM28L
BM32L
BM39L
B28
B32
B39
5240
7870
11610
4.0
6.25
9.0
32
38
44
42
53
63
11
13
15
311⁄2
351⁄2
43
281⁄4
323⁄4
393⁄4
79
116
140
Exhaust†
Gravity
Shutter
Supply
CFM*
.18" S.P.
**Throat
Area
Sq. Ft.
Vent
12" Curb
*Max. supply for < 650 FPM (snow intake velocity) Max. exhaust. = 1.5X air supply
°Outside dimension
†Gravity damper will not operate as barometric damper.
**Throat dimensions equivalent to model number (X) Available models
ROOF FAN CURBS AND ADAPTERS
• 18 gauge galv. steel
• fiberglass insulation
• neoprene pad
• continuous welds
• sturdy shutter shelf
• self flashing
Standard height = 12"
(other heights available)
Pitched curbs are special order.
Adapter permits equal (based on performance) fan replacement without
disturbing existing roof curb. Many other sizes not shown available.
• Sturdy…weather tight
• Continuous welds.
• 18 ga. galv. Steel.
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
DIMENSIONS
M
Ship
Wt.
O.D.
I.D.
C1312
C1512
121⁄2
151⁄4
91⁄4
12
8
10
18
21
C1912
C2012
181⁄2
20
151⁄4
163⁄4
131⁄2
143⁄4
26
31
C2412
C2812
231⁄2
271⁄2
201⁄4
241⁄4
181⁄4
221⁄4
34
39
C3212
C3412
311⁄2
331⁄2
281⁄4
301⁄4
261⁄4
281⁄4
43
46
C3612
C3812
351⁄2
371⁄2
321⁄4
341⁄4
301⁄4
*
48
50
C4012
C4312
391⁄2
43
361⁄4
393⁄4
341⁄4
373⁄4
52
56
C4612
C4912
451⁄2
49
421⁄4
453⁄4
401⁄4
65
69
C5512
C6112
55
61
513⁄4
573⁄4
*
*
*
75
80
*No shelf
CURB ADAPTERS
CURB ADAPTERS
46
Curb
Model
No.
CATALOG #37
www.centralfan.com
Dimensions
Model
No.
A
B
CA 1815
CA 1855
CA 1915
18
181⁄2
19
151⁄2
151⁄2
151⁄2
CA 2015
CA 2118
201⁄2
21
151⁄2
181⁄2
CA 2218
CA 2220
22
22
181⁄2
201⁄2
CA 2515
CA 2518
CA 2520
25
25
25
151⁄2
181⁄2
201⁄2
CA 2820
CA 2823
28
28
201⁄2
231⁄2
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
Lau Double Inlet Blowers
FORWARD CURVE - DOUBLE WIDTH WHEELS - BELT DRIVE
Low cost double inlet blowers with double width wheels for those applications not requiring duct to the inlet end.
Their compact design and quietness of operation make these blowers popular for residential and commercial
heating and air conditioning.
Belt driven for flexible choice of speeds and air outputs, with standard motors that are easy and economical to
replace if necessary.
CLOCKWISE OR CCW ROTATION - (facing motor shaft). Bottom horizontal discharge unless otherwise specified. Discharge position can be easily changed.
Long life bronze bearings - Oversized belt drive - True running balanced wheels. Furnished with soft rubber
vibration bushings. Use ball bearings for 3/4 HP or greater motor.
BARE BLOWER
(NO MOTOR DRIVE)
Model
Wt.
No.
Lbs
A9-6
17
A9-7
19
A9-9
22
A10-6
22
A10-8
23
A10-10
26
A12-6
37
A12-9
39
A12-12*
41
A15-9
50
A15-11
52
A15-15*
65
A18-13
90
A18-18*
100
See p.10 for special motors
Assembled & Tested Blower
(With motor and drive on blower)
Model
A
B
C
D
E*
F*
G*
H*
HP
1Ø 1 Speed
1Ø 2 Speed
3Ø 1 Speed
1
X
X
X
–
X
X
–
X
X
1
X
X
X
X
X
X
X
X
X
11⁄2
2
X
X
–
–
X
X
⁄6
1
⁄4
1
⁄3
1
⁄2
3
⁄4
*Use ball bearings
(X) Available models
DIMENSIONS
Model
Number
A
A
A
A
A
A
A
A
A
A
A
A
A
A
9-6 ACE
9-7 ACE
9-9 ACE
10-6 ACE
10-8 ACE
10-10 ACE
12-6 ACE
12-9 ACE
12-12 ACE
15-9 ACE
15-11 ACE
15-15 ACE
18-13 ACE
18-18 ACE
K
81⁄4
93⁄16
117⁄8
81⁄4
101⁄2
131⁄8
813⁄16
123⁄8
153⁄4
1213⁄16
1411⁄16
185⁄8
173⁄8
217⁄8
E
A
101⁄4
101⁄4
101⁄4
113⁄8
113⁄8
113⁄8
137⁄16
137⁄16
137⁄16
157⁄8
157⁄8
157⁄8
187⁄8
187⁄8
157⁄16
157⁄16
157⁄16
171⁄4
171⁄4
171⁄4
207⁄16
207⁄16
207⁄16
241⁄8
241⁄8
241⁄8
293⁄16
293⁄16
B
1415⁄16
1415⁄16
1415⁄16
161⁄2
161⁄2
161⁄2
195⁄16
195⁄16
195⁄16
225⁄8
225⁄8
225⁄8
27
27
Shaft
Size
⁄4
⁄4
⁄4
3
⁄4
3
⁄4
3
⁄4
3
3
3
1
1
1
1
1
1
1
1
BLOWER PERFORMANCE
1
⁄4" SP
CFM
400
600
800
1000
400
600
800
1000
600
800
1000
1200
1400
400
600
800
1000
1200
1400
600
800
1000
1200
1400
800
1000
1200
1400
1600
1800
600
800
1000
1200
1400
1600
1800
1000
1200
1400
1600
1800
2000
1400
1600
1800
2000
2200
2400
2600
1500
2000
2500
3000
3500
4000
4500
5000
2000
2500
3000
3500
4000
2000
2500
3000
3500
4000
4500
3000
3500
4000
4500
5000
5500
6000
3000
3500
4000
4500
5000
5500
6000
6500
7000
RPM
556
575
630
700
553
586
599
644
566
589
623
663
710
491
500
529
577
635
695
477
492
517
550
586
490
507
529
558
591
635
414
417
439
472
509
542
581
400
410
424
447
470
496
424
436
451
463
486
507
530
347
375
411
458
493
540
589
637
344
368
396
441
479
350
370
395
429
467
505
309
327
352
377
400
427
455
302
315
340
351
367
388
407
423
439
HP
.07
.09
.12
.18
.07
.09
.11
.14
.10
.12
.15
.19
.25
.06
.09
.12
.16
.21
.30
.06
.10
.12
.17
.21
.13
.16
.18
.22
.25
.32
.11
.11
.14
.18
.23
.30
.32
.11
.13
.15
.19
.23
.27
.16
.18
.22
.26
.30
.36
.42
.17
.25
.36
.52
.73
1.05
1.37
1.75
.21
.30
.41
.50
.84
.20
.27
.36
.49
.68
.88
.31
.41
.58
.70
.90
1.17
1.33
.28
.36
.48
.61
.74
.90
1.12
1.28
1.50
1
⁄2" SP
RPM
783
769
794
845
807
790
793
813
788
787
803
828
863
704
686
697
724
765
813
700
693
690
727
734
700
693
705
718
739
763
593
577
586
602
623
647
677
566
563
566
575
580
600
574
579
587
596
609
623
638
472
483
503
534
564
605
648
690
459
467
487
512
543
480
488
504
524
552
579
415
423
435
448
463
483
502
414
418
427
437
449
463
476
492
508
HP
.11
.13
.16
.22
.09
.13
.16
.19
.14
.16
.20
.25
.32
.11
.13
.16
.21
.29
.38
.11
.14
.17
.23
.28
.20
.21
.26
.29
.34
.40
.18
.19
.22
.27
.32
.37
.43
.18
.21
.23
.27
.31
.37
.26
.29
.32
.37
.42
.47
.54
.24
.34
.46
.62
.87
1.22
1.58
2.05
.30
.40
.53
.73
1.00
.31
.40
.52
.67
.86
1.06
.52
.58
.73
.90
1.10
1.36
1.62
.47
.56
.65
.80
.96
1.13
1.36
1.60
1.87
3
⁄4" SP
RPM
992
950
958
986
986
954
946
954
998
972
964
980
1005
872
841
838
854
880
918
863
836
829
836
847
859
843
841
847
863
883
735
712
708
712
726
744
765
714
697
688
689
695
705
700
702
704
711
718
728
740
582
576
590
608
633
667
703
745
562
563
573
590
611
595
592
598
610
626
647
497
500
506
514
527
541
557
505
503
505
511
521
531
542
556
571
HP
.15
.17
.21
.27
.14
.19
.22
.26
.20
.23
.27
.33
.40
.15
.16
.21
.27
.34
.45
.17
.18
.22
.30
.35
.28
.30
.33
.38
.43
.50
.24
.26
.30
.34
.39
.45
.55
.28
.29
.32
.36
.41
.48
.33
.37
.42
.47
.52
.58
.65
.34
.44
.60
.81
1.06
1.42
1.80
2.30
.42
.52
.67
.89
1.17
.45
.55
.67
.83
1.02
1.25
.64
.76
.92
1.11
1.38
1.60
1.89
.61
.71
.83
.99
1.19
1.42
1.67
1.88
2.20
1" SP
RPM
1156
1102
1092
1100
1133
1118
1097
1092
1148
1127
1109
1111
1123
1014
983
963
969
989
1017
1013
981
963
958
960
1002
977
967
968
987
991
852
835
812
811
820
832
851
828
815
800
794
791
795
816
809
811
812
817
823
831
666
657
665
680
702
729
761
800
654
652
654
663
679
695
682
679
685
695
712
570
571
576
582
590
599
613
593
585
581
583
589
596
606
616
629
HP
.19
.21
.25
.37
.19
.22
.31
.34
.25
.29
.33
.39
.47
.18
.21
.26
.31
.40
.52
.22
.25
.31
.35
.44
.37
.38
.42
.45
.53
.60
.30
.32
.36
.41
.47
.54
.64
.36
.38
.42
.45
.51
.57
.42
.47
.51
.56
.62
.69
.76
.43
.56
.72
.95
1.23
1.55
2.02
2.50
.52
.66
.82
1.05
1.32
.56
.69
.81
.97
1.17
1.44
.76
.94
1.13
1.37
1.54
1.85
2.14
.82
.93
1.06
1.22
1.43
1.66
1.94
2.20
2.52
*Ball bearings std.
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
CATALOG #37
www.centralfan.com
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
47
American
Coolair
BELT DRIVE UPBLAST AXIAL ROOF FAN
•
•
•
•
Heavy gauge steel construction with baked epoxy finish
Fiberglass butterfly dampers serve as skylight when not in operation
Unpainted galvanized steel windband
Magnetic latches prevent damper flap when fan is not in operation
SPECIAL ORDER MODELS JT AND HS
MODEL JBH
• JT Model has motor & drive removed from air stream and accessible from roof.
• HS model for heat & smoke removal. Continuous operation at 650°F. Intermittent to 1200°F
STD. Model JBH
Open Motor*
Model
No.
HP
1 Phase
S
3 Phase
T
X
X
X
Model JBH Performances
CFM
Static pressure (inches H2O)
12"
High
Curb
Fan
RPM
0
949
1048
1075
7901
8725
8950
6564
7537
7795
6860
7143
C4312
798
887
965
1113
11780
13094
14245
16430
9724
11255
12559
14969
10279
11692
14234
607
670
725
826
15425
17026
18423
20990
14082
15774
18688
14162
17417
15759
19534
1
3
⁄4
E
JBH24 F
G
3
1
11⁄2
X
X
X
F
JBH30 G
H
J
1
11⁄2
2
3
X
X
X
X
X
X
X
X
F
JBH36 G
H
J
1
11⁄2
2
3
X
X
X
X
X
X
X
X
C4912
G
JBH42 H
J
1
1 ⁄2
2
3
X
X
X
X
X
X
C5512
533
579
659
20363
22121
25177
15703
18007
21857
H
JBH48 J
2
3
X
X
X
X
C6112
469
533
26870
30537
20378
25086
⁄4
C3812
⁄8
1
⁄2
Sones
@5'
JBH
Ship
Wt.
31
38
40
240
242
282
26
31
36
48
315
335
340
362
23
27
31
38
367
385
395
412
27
31
38
470
475
500
29
35
620
640
5000†
6489
7700†
10727
13478
9000†
15989
14000†
17737
17000†
21687
† Min. CFM to yield O.V. = 1850 FPM prevents entry of rain during operation. Low speed operation (2-sp. motor) could allow PPT. entry
Two speed operation is therefore limited. *Special motors p. 10. (X) Available models
Note: Motor and drive assembled and tested on fan panel
Fan panel, dampers and windband are separate for ease of handling in shipping and site location.
SPECIAL ORDER MODELS JT-HS
STANDARD MODEL JBH
MODEL JBH
DIMENSIONS
Model
No.
A
B
C
D
JBH 24
JBH 30
32
38
283⁄4
335⁄8
38
44
32
38
117⁄8
163/4
51⁄8
51⁄8
JBH 36
JBH 42
44
50
335⁄8
381⁄2
50
56
44
50
17
17
JBH 48
56
391⁄2
62
56
17
48
E
F
MODEL JT
Model
No.
MODEL HS
DIMENSIONS
Model
No.
DIMENSIONS
A
B
C
D
H
J
JT 24
JT 30
32
38
531⁄4
581⁄4
38
44
301⁄4
361⁄4
28
28
301⁄2
341⁄2
HS 24
HS 30
57
57
51⁄8
51⁄8
JT 36
JT 42
44
50
661⁄8
71
50
56
421⁄4
481⁄2
36
36
415⁄8
451⁄4
HS 36
HS 42
51⁄8
JT 48
56
71
62
545⁄8
36
483⁄4
HS 48
CENTRAL FAN CO., INC.
3890 MYSTIC VALLEY PKWY.
MEDFORD, MA 02155
CATALOG #37
www.centralfan.com
A
B
D
F
18
18
67
78
14
38
30
14
44
36
SEE MODEL
JT
15
50
42
17
56
48
C
88
20
27
62
PHONE: (781) 393-4456
1-800-937-4326
FAX: (781) 396-4581
54
19
20

Similar documents