Birtley Lintels Brochure PDF Brochure
Transcription
Birtley Lintels Brochure PDF Brochure
CI/SfB (31.9) Hh2 (M2) JULY 2012 Birtley Building Products Ltd Mary Avenue, Birtley, County Durham DH3 1JF. Tel: 0191 410 6631 Fax: 0191 410 0650 Email: [email protected] Internet: www.birtley-building.co.uk A member of the Hill & Smith Holdings Plc Group. Registered No:00602575 England. Registered Office: Springvale Business & Industrial Park, Bilston, Wolverhampton WV14 0QL The only complete range of lintels hot-dip galvanized after manufacture Contents Commitment to Quality: Supergalv Performance Features Lintel Reference 4-6 AT 50 Constructive Innovation: Product Specification 7 Custom-built Versatility: Purpose Made Lintels Technical Advisory Service 8-9 10 Firm Foundations: Design and Building Practice 11 - 12 Supergalv: The Complete Range of Lintels 13 - 30 Accessories: Archform and Soffit Cover 31 Bay 6: Corner Window Support System 32 - 33 Custom Specification: Fax Back Specification Form Page No Lintel Reference Page No 25 HDX 50 14 AT 70 25 HDX 70 15 AT 90 25 HDX 90 16 HDX 110 17 CB 50 14 HDX 130 18 CB 70 15 HDX 150 19 CB 90 16 HDX 50/130 20 CB 110 17 HDX 70/130 21 CB 130 18 HDX 90/130 22 CB 150 19 INT 100 30 CB 50/130 20 INT 100 HD 30 CB 70/130 21 LA 28 MBL 28 OB 190 27 SB 100 26 CB 90/130 22 CB 125/90/100 24 CB 50 HD 14 CB 70 HD 15 CB 90 HD 16 CB EV 50 24 CB EV 90 24 SB 100 HD 26 DC 200 27 SB 100 HDX 26 DC 200 HDX 27 SB 140 26 SB 140 HD 26 SB 140 HDX 26 SBL 200 27 34 - 35 EV 100 28 HS 50 14 SEMICIRCULAR HS 70 15 ARCHES 30 HS 90 16 SX 90 23 HS 110 17 HS 130 18 TF 50 29 HS 150 19 TF 50 HD 29 HS 50/130 20 XHD 90 23 HS 70/130 21 HS 90/130 22 HS 90/200 23 ACCESSORIES: HS 125/90/100 24 ARCHFORM 31 SOFFIT COVER 31 RENDER KEY BAY6 2 3 31 32-33 Commitment to Quality Performance Features Corrosion Protection With over 40 years experience in the specification, design and manufacture of steel lintels, Birtley Building Products stands at the forefront of technological change and innovation. All Supergalv lintels are protected by hot-dip galvanizing the complete lintel after fabrication. This process out performs all other protection systems by: Investment in manufacturing technology continues to underpin Birtley’s commitment to the UK lintel market, and to ensure that the Supergalv range maintains its leading position when measured by quality, performance, durability, design and cost-effectiveness. Fully protecting every surface, cut edge and weld with a metallurgically bonded zinc coating, where other systems actually remove zinc during fabrication and do not provide full protection to all surfaces. At the heart of Birtley’s lintel production today is a fully automated, computer-controlled manufacturing line that processes the product from raw coil to finished item in a single sequence. This maintains a consistent, precision, quality lintel while achieving extraordinary levels of output. The plant was custom designed to Birtley’s specification and manufactured by Europe’s leading suppliers of metal-forming machinery, and this multi-million pound investment underlines the long-term commitment of Birtley to the lintel industry. Creating a build-up of zinc coating at the most vulnerable points (edges etc.) which are more susceptible to damage on site and are the least protected in other systems. Depositing a minimum zinc coating thickness of 65µm in a metallurgical bond over the base steel. Optional ‘Ultragalv 2000’ (U2k) corrosion protection system. This achieves a coating thickness of 150µm by shotblasting the steel prior to galvanising. This is up to 7 times more Zinc corrosion protection than other lintels, and the life of a Zinc coating is directly proportional to its thickness. Insulation All external cavity wall lintels are insulated with expanded polystyrene blocks to BS EN 13163. The insulation is CFC, HCFC and HFA free and these agents are not used at any stage in manufacture. All lintels comply with Parts L1 and L2 of the Building Regulations approved documents. The insulation has an ozone depletion potential of zero, and being blown with pentane achieves a BREEAM credit for having a global warming potential of zero. Beyond the automated lintel line lies the state-of-the-art technology built in to the Company’s galvanizing facility, the UK’s first fullyautomated, hot-dip galvanizing plant. Commissioned at a cost of over £2.5 million, it incorporates one of the UK’s largest galvanizing baths. This computer-controlled facility utilises proven European technology to achieve a level and consistency of quality never before seen in this country, while substantially increasing Birtley’s capacity and lowering manufacturing costs. We have a fully-computerised lintel scheduling function where the expertise of our Technical Advisory Service provides support and advice in the specification of lintels, including the provision of structural calculations for building regulation submissions, and the design of special lintels or steelwork to suit particular projects or unusual forms of construction. All this is supported by extensive stocks held at Birtley of all the most popular lintel types, offering ready availability at all times. Flexible production systems ensure a rapid response to all other lintel requirements. Most important of all, though, is the close partnership which exists between Birtley and its nationwide network of builders’ merchants and distributors, whose commitment to stocks of Supergalv lintels allows them to provide an excellent level of service, whenever and wherever required. 4 The underside of the insulation is ridged to act as an efficient plaster key and the absence of a baseplate removes any possibility of a coldbridge occurring at the window head. Structural Performance The structural performance of Supergalv lintels is supported by systematic and extensive in-house testing and confirmed by independent testing. Lintels have been tested for structural performance, flexural strength and shear load resistance by the University of Wales School of Engineering and the University of Teesside Heavy Structures Test facility. The safe working loads shown are derived from calculations on the physical properties supported by tests, and refer to uniformly distributed loads applied in the ratio of: ‘CB’ range 1:1 to 1:3 ‘CB HD’ range 1:1 to 1:5 ‘HS’ ‘AT’ range 1:5 to 1:19 ‘HDX’ range 1:5 to 1:19 ‘SX’ range 1:5 to 1.19 ‘XHD’ range 1:5 to 1:19 For loads ratios beyond this range, or for any unusual loading conditions, please contact our Technical Department for advice. 5 Regulatory Authority Relative Performance of Corrosion Protection Systems as Applied to Steel Lintels Supergalv lintels are designed and manufactured taking into account the requirements of: The current British/European standard (BS EN 8452:2003) allows various grades of corrosion protection, with the responsibility for compliance resting with the specifier, who must take into account exposure categories and local climatic conditions. Don’t be caught out, specify the correct system for the job. - BSI - NHBC - HAPM (Housing Association Property Mutual) - Zurich Municipal Life to First Maintenance Chart - BRE Based on category 3 exposure (moderate to severe), as defined by ‘Galvanizers Association’ (1.5µm per annum Zinc atmospheric corrosion rate). All lintels conform fully to EN 845-2:2003. The Supergalv CB Range - feature-packed design for the 21st Century. The CB range is designed for ease of installation and to exceed the performance requirements of all existing standards. In applying state of the art technology to improve design standards, we have also recognised our duty to the environment by selecting an insulation system which is 100% CFC-free, HCFC free and has both an ozone depletion of zero, and a global warming potential of zero. 110 YEARS Thermal values of wall construction maintained through lintel. Easily installed, locating entirely within cavity. The Supergalv range is considered non-hazardous to health under normal conditions of use, as laid down by the COSHH regulations 1994. Please refer to page 11 for advice on the correct storage, handling and installation of lintels. 60 Manufacture 50 Supergalv lintels are produced from decoiled slit steel, cut to length and cold formed by press-braking. Where appropriate, seam welding to BS6265 1982 or spot welding to BS 1140 1980 completes fabrication. All lintels are then hot-dip galvanized following an extensive chemical pre-treatment, by immersion in our own galvanizing bath operating at a temperature of 450˚C. Lintels are then allowed to air cool to avoid any risk of distortion. 20 10 Fully insulated lintel - no air gaps, no interruptions, pure insulation. Although the Supergalv and Ultragalv processes offer the highest level of corrosion protection available, there may be instances where the use of stainless steel may be more appropriate, e.g. certain industrial applications, or marine environments. To satisfy these requirements we can offer our full range of lintels fabricated from stainless steel to BS EN 10088-2 (304 S15). Other grades may also be available, please contact Technical Department for advice. 80 30 Design provides firm location for masonry to maintain dimensions and integrity of cavity. Corrosion protection is provided by zinc to BS EN 1179: 2003 Health & Safety 40 Simple plastering and curtain-batten fixing etc. to blockwork. Supergalv lintels are manufactured from steel to BSEN 10025 Fe 430 A, having a minimum yield stress of 300 N/mm2. 90 70 No need to cut blocks. Material Where appropriate external wall lintels are insulated with CFC-free expanded polystyrene manufactured under BS EN ISO 9001 and BS 13163. 100 Just compare the features of the CB: Constructive Innovation 0 High-grade, flame retardant EPS insulation. Birtley ‘Ultragalv 2000’ (optional) Risk of cold bridging eliminated by thermal barrier of insulating foam and absence of steel bridge between outer and inner skin. Integral plaster-key in base flange eliminates need for messy and dangerous mesh. 150µm Birtley ‘Supergalv’ (standard) 65µm Other manufacturers 42µm Fire Resistance Supergalv lintels have been tested and approved to BS476 : Part 20 : 1987 for determination of the fire resistance of loadbearing elements of construction. Test reports are available on request. Zinc Corrosion Rates Category Category Category Category Category Base of insulating material provides additional plaster-key. Single thickness of steel simplifies locating within brickwork joint. 1 2 3 4 5 : : : : : 0.5µm 1.0µm 1.5µm 2.0µm 2.5µm per per per per per annum annum annum annum annum For other information and localised conditions, see the ‘Architects and Engineers Guide to Hot-Dip Galvanizing’, published by the Galvanizers Association, or check the web site www.galvanizing.org.uk The CB is designed to suit standard duty applications up to 3900mm long, with a Medium Duty range to 3000mm for loads up to 36kN. 6 Quality Assurance Birtley Building Products is a British Standards Institute (BSI) registered firm, with a quality system conforming to BS EN ISO 9001 : 2008, covering procedures for lintel manufacture and galvanizing. This commitment to quality is reinforced by the award of the BSI Kitemark to lintels within the range. All Supergalv lintels fully satisfy the requirements of EN 845-2:2003. 7 Custom-built Versatility Custom Options Purpose Made Lintels When the building design demands something out of the ordinary, Supergalv lintels can be custom-designed and manufactured to suit a wide variety of opening shapes, dimensions and loadings. Typical special applications include: Arch lintels, e.g. Natural Arch, Gothic Arch, Radius Arch Corner lintels Curved in Plan lintels Apex lintels Cant brick lintels Extra heavy duty lintels Roller shutter lintels Extra long span lintels (to 9.5m) Purpose-made lintels are designed and manufactured in close liaison with the specifier and contractor, including the provision of full structural calculations where required, ensuring that all requirements are satisfied and that installation is straightforward. As well as an infinite range of special lintel designs to suit any architectural design or loading requirement, Supergalv lintels are available in all cavity wall styles adapted to suit special circumstances. Please contact our Technical Advisory service for details and information on price and availability. Examples of these special service lintels are: CP Where the underside of the lintel is completely exposed, e.g. porches, driveways, etc., a closer plate can be welded prior to galvanizing to provide a neat, aesthetically pleasing finish to the soffit of the lintel. To specify, add ‘CP’ to the end of the lintel reference, e.g. CB50 CP. (Lintel will be supplied uninsulated, unless specified otherwise). NM Where the inner leaf of a cavity wall is fair-faced and the inner flange of the lintel is not plastered, the plaster key on this flange can be omitted. To specify, add ‘NM’ to the end of the lintel reference, e.g. CB50 NM. Manufactured within Birtley utilising CAD and CNC fabrication facilities, all purpose-made lintels comply fully with EN 845-2:2003, are manufactured within the QA systems of BS EN 9001 and, very importantly, are finished to the same standard of corrosion protection as the standard range of Supergalv lintels - i.e. 65µm zinc coating to all surfaces, applied by hot-dip galvanizing after fabrication. Optional ‘Ultragalv 2000’ offers minimum of 150µm of Zinc projection. Purpose made lintels are also available in stainless steel to BS EN 10088-2. ND To minimise the mortar bed thickness at the end bearings, e.g. when using stone heads and surrounds, the weather drip on the front flange of the lintel can be omitted. To specify, add ‘ND’ to the end of the lintel reference, e.g. CB50 ND. U2K ‘Ultragalv 2000’ maximum corrosion protection with 150µm Zinc coating. To specify add ‘U2K’ to the end of the lintel reference, e.g. CB50 U2K. Our technical department can also offer guidelines for installation of special lintels, as some designs, such as curved on plan and lengths over 4.8m which may need to be propped during installation. Patents Supergalv lintels and Birtley Building Products are protected by the following Patents and Trade Marks: 2 019 250 2 063 331 2 063 953 2 083 093 2 103 680 2 185 764 2 271 367 7 936 481 2001478 120787 Eire 8 9 Technical Advisory Service Birtley Building Products provides comprehensive technical support to designers, specifiers, builders and merchants covering all aspects of the design, specification and installation of Supergalv lintels. The service includes : Computer-based preparation of Lintel Schedules from drawings supplied (preferably plans, elevations and sections including floor joist layout and loadings, concrete floor directional spans and loading, and roof layout as appropriate). Provision of structural calculations for Building Regulation approval by individual calculation for specific locations. Advice on the use of lintels for unusual situations, e.g. reduced end bearings, point loadings, use of lintels in refurbishment projects, etc. Detailed drawings to illustrate the use of lintels in particular situations. Design & Building Practice for Steel Lintels Specifications NHBC Standards BS 5977: Part 1: 1981 (1986) AMD. 4796 Method for Assessment of Load. Part EN 845-2:2003 Specification for Prefabricated Lintels. BS 476: Parts 20 - 23 Test methods and criteria for the fire resistance of elements of building construction. BS EN ISO 1461:1999 Specification for Hot Dip Galvanized Coatings on Iron and Steel Articles. BS7668, BS EN 10029, BS EN 10025 Parts 1, 3, 4 and 5, and BS EN 10210 Part 1 Weldable Structural Steels. BS EN ISO 14713-2:2009 Protective Coating of Iron and Steel Structures Against Corrosion. 6: SUPERSTRUCTURE 6.1 External Masonry Walls Clause D6 (b) Design D9 Design M8 Materials Sitework S6 6.2 External Timber Framed Walls and Wall Panels Clause 8.2 (b) 6.3 Internal Walls Clause D5 Design S3 (F) Sitework Design Considerations PD 6697:2010 Recommendations for the design of masonry structures to BS EN 1996-1-1 and BS EN 1996-2. All Supergalv Lintels are designed to satisfy the following requirements: Loadings Building Regulations • The proportion of Live Load to Total Load carried by the Lintel must not exceed 50%. A safety factor of 1.6 is allowed in all published Safe Loads. REGULATION 4: Requirements relating to building work. REGULATION 6: Requirements relating to material change of use. • Point Loads are permissible in certain circumstances. REGULATION 7: Materials and workmanship. Schedule Part A: Part B: Part C: Part L: 1 Requirements Structure Fire Resistance to Moisture Conservation of Fuel and Power Approved A1: B3: B4: C4: L2: L3: Documents Loading Internal Fire Spread (Structure) External Fire Spread Resistance to Weather and Ground Moisture Resistance to the Passage of Heat (Dwellings) Resistance to the Passage of Heat (Buildings other than Dwellings) • A lintel shall have a maximum Horizontal or Vertical Deflection of 1/200 x the Effective Span* when subjected to the Safe Working Load. *(Effective Span = Distance between the Centres of Bearings) Dimensional Deviations Length Width & Height Straightness or bow +/- 15mm +/- 5mm 0.5% of the length, up to a maximum of 10mm Bearings • The end bearings for lintels should normally be not less than 100mm. In no case should the lintel tray extend less than 50mm beyond the cavity side of the solid masonry return to drain clear of a vertical dpc. Materials and Workmanship to Support Regulation 7. • The width of a lintel bearing on an inner leaf should be equal to at least 80% of the thickness of that leaf. • The overhang of masonry supported by lintel should not exceed 25mm. • The cavity widths shown in our tables are maximum dimensions and must not be exceeded. For details of which lintel ranges have been assessed see website 10 11 Design & Building Practice for Steel Lintels Damp Proof Systems HAPM Rating • Good building practice encourages the use of a separate damp proof course to a lintel in all external wall-situations, and Birtley Building Products endorses this approach in all circumstances. • The HAPM Component Life Manual assesses the life to first maintenance for Supergalv lintels as 45 years when used in accordance with the manufacturer’s instructions. This exceeds the maximum 35+ year rating of Class A standard. • Regardless of lintel profile or corrosion protection system, BRE and NHBC require the application of a separate dpc in all buildings in Scotland, Northern Ireland and all coastal regions and areas of Severe Exposure (as defined in BRE Digest 127) in England. Material Compatibility • Mortar must comply with the requirements of BS 5628 (Part 3: 1985). • Timber preservatives used for the protection of joinery components (e.g. windows) are unlikely to affect galvanized steel except that preservatives based on copper-chrome-arsenic (CCA) and inorganic flame retardants may attack galvanized steel (ref. BRE IS 11/77). • The cavity tray should have a vertical height of at least 140mm with a minimum rise of 100mm from the front of the cavity. The length of the tray should be such that it extends 150mm beyond the inner face of the cavity closer. The cavity tray should extend beyond the front toe of the lintel to protect door and window heads, with the upstand returned into the inner leaf masonry. • If possible, provision of all necessary fixing holes should be arranged so as to be carried out at the time of fabrication and before galvanizing. • Stop ends should be provided by turning up the ends of the tray, or by the use of separate self-adhesive units. A minimum of two bedweeps should be used at 450mm centres. Installation Advice • Do not use damaged lintels, inspect at delivery stage. Fire Resistance • Do not bear lintels onto cut blocks, always use full masonry units or padstones. • The BRE Fire Research Station ‘Guidelines for the Construction of Fire Resisting Structural Elements’ gives design recommendations applicable to lintels. • Do not dry bed lintels on bearings. Mortar beds should be used to prevent lintel settling under load. • Independent test reports in accordance with BS 476 are available from Supergalv Lintels. • Do use an additional DPC. Thermal Insulation • Do use stop ends and bedweeps (at 450mm centres) to all lintels in fairfaced masonry walls. • Normally the thermal conductivity of an exposed wall is limited to a maximum U Value of 0.35 W/m2K in dwellings and other residential buildings, industrial or storage buildings, where the prescribed maximum area for glazing and minimum standards of insulation for solid areas are adhered to. THE ONLY COMPLETE RANGE OF L I N T E L S HOT DIP GALVANIZED AFTER MANUFACTURE • Do ensure that open back lintels are filled with properly bonded masonry before work proceeds over. • Do ensure that both leaves of the cavity wall are raised equally to avoid eccentric loading of lintel flanges. • To avoid cold bridging over the wall face area behind the lintel, the masonry or insulation system of the designed value should be maintained to the head level of the lintel. • Do position concrete floor units carefully and gently to avoid impact damage and shock loads which may temporarily over stress the lintel with resultant excessive deflection or distortion. • Do make sure that the lintel toe projects beyond the window head to prevent water ingress. • Lintels of Open Back design achieve the same U value as the wall by being filled with the same blockwork and insulation material. This allows an increase in single glazed window area. Lintels of Box design can be supplied with expanded polystyrene blocks for additional insulation. • Do ensure that the maximum cavity width is not exceeded, and that masonry does not overhang by more than 25mm. Supergalv Lintels cannot be held responsible for any errors or omissions in this listing, nor for any consequences which may arise directly or indirectly from its use. As part of our policy of continuous product improvement we reserve the right to change specifications without notice. 12 13 Cavity Walls Cavity Walls We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width Outer Leaf Cavity Inner Leaf 250 to 270 STANDARD DUTY Overall Width 100 Outer Leaf 50 to 70 Cavity 100 to 115 Length Range mm CB 50 We recommend the use of an additional cavity tray with all external cavity wall lintels 750 - 1200 Inner Leaf Max UDL Depth kn mm 15 112 Weight kg/m 5.8 1350 - 1650 15 112 7.3 1800 - 2100 20 143 8.1 270 to 290 100 70 to 90 100 to 115 Length Range mm CB 70 STANDARD DUTY Max UDL Depth kn mm Weight kg/m 750 - 1200 15 106 5.8 1350 - 1650 15 106 7.3 1800 - 2100 20 148 8.1 2250 - 2400 22 148 9.9 2250 - 2400 22 148 10.1 2550 - 2700 26 175 11.0 2550 - 3000 26 185 11.6 2850 - 3000 26 190 11.6 3300 - 3900 26 200 14.2 3300 - 3900 26 205 Not recommended for the support of P.C.Concrete floors 14.2 Not recommended for the support of P.C.Concrete floors CB 50 HD MEDIUM DUTY 750 - 1500 36 153 10.1 1650 - 2100 36 205 14.2 2250 - 3000 36 205 CB 70 HD MEDIUM DUTY 750 - 1500 36 148 10.1 1650 - 2100 36 200 14.2 2250 - 3000 36 208 14.6 Not recommended for the support of P.C.Concrete floors 14.5 Not recommended for the support of P.C.Concrete floors HS 50 HEAVY DUTY HDX 50 EXTRA HEAVY DUTY 750 - 1200 70 225 19.4 1350 - 1800 70 225 19.4 HS 70 HEAVY DUTY 750 - 1200 70 225 19.4 1350 - 1800 70 225 19.4 1950 - 2100 60 225 19.4 1950 - 2100 60 225 19.4 2250 - 2700 60 225 19.4 2250 - 2700 60 225 19.4 2850 - 3000 55 225 19.4 2850 - 3000 55 225 19.4 3300 - 3900 50 2225 19.4 3300 - 3900 50 225 19.4 4200 - 4500 40 225 19.4 4200 - 4500 40 225 19.4 4800 35 225 19.4 4800 35 225 19.4 5100 25 225 19.4 5100 25 225 19.4 750 - 2100 100 225 31.1 2250 - 3300 80 225 31.1 3600 - 4200 70 225 31.1 750 - 2100 100 225 31.1 2250 - 3300 80 225 31.1 HDX 70 EXTRA HEAVY DUTY 3600 - 4200 70 225 31.1 4500 - 4800 60 225 31.1 4500 - 4800 60 225 31.1 5100 45 225 31.1 5100 45 225 31.1 Denotes Plaster Key 14 Denotes Plaster Key 15 Cavity Walls Cavity Walls We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width Outer Leaf Cavity Inner Leaf 290 to 310 STANDARD DUTY Overall Width 100 Outer Leaf 90 to 110 100 to 115 Length Range mm CB 90 We recommend the use of an additional cavity tray with all external cavity wall lintels 750 - 1200 Max UDL Depth kn mm 15 106 Weight kg/m 5.9 1350 - 1650 15 106 7.4 1800 - 2100 20 138 8.4 2250 - 2400 22 151 10.4 2550 - 3000 26 187 12.0 3300 - 3900 26 202 14.2 310 to 330 100 Cavity 110 to 130 Inner Leaf 100 to 115 Length Range mm CB 110 STANDARD DUTY Max UDL Depth kn mm Weight kg/m 750 - 1500 20 138 8.6 1650 - 2100 20 143 10.7 2250 - 2700 25 173 11.8 2850 - 3300 30 195 14.9 Not recommended for the support of P.C.Concrete floors Not recommended for the support of P.C.Concrete floors CB 90 HD MEDIUM DUTY 750 - 1500 36 138 10.5 1650 - 2100 36 195 13.9 2250 - 3000 36 202 14.2 HS 110 HEAVY DUTY Not recommended for the support of P.C.Concrete floors HS 90 HEAVY DUTY HDX 90 EXTRA HEAVY DUTY 750 - 1200 70 225 19.4 1350 - 1800 70 225 19.4 1950 - 2100 60 225 19.4 HDX 110 EXTRA HEAVY DUTY 750 - 2100 60 225 21.7 2250 - 2700 60 225 21.7 2850 - 3000 55 225 21.7 3300 - 3900 50 225 21.7 4200 - 4500 40 225 21.7 4800 35 225 21.7 5100 35 225 21.7 750 - 2100 100 225 31.1 2250 - 3300 80 225 31.1 3600 - 4200 70 225 31.1 2250 - 2700 60 225 19.4 4500 - 4800 60 225 31.1 2850 - 3000 55 225 19.4 5100 45 225 31.1 3300 - 3900 50 225 19.4 4200 - 4500 40 225 19.4 4800 35 225 19.4 5100 25 225 19.4 750 - 2100 100 225 31.1 2250 - 3300 80 225 31.1 3600 - 4200 70 225 31.1 4500 - 4800 60 225 31.1 5100 45 225 31.1 Versions also available for 125 to 140 inner leaf Denotes Plaster Key 16 Denotes Plaster Key 17 Cavity Walls Cavity Walls We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width Outer Leaf 330 to 350 STANDARD DUTY Overall Width 100 Outer Leaf HEAVY DUTY HDX 130 EXTRA HEAVY DUTY 100 130 to 150 Cavity 150 to 170 Inner Leaf 100 to 115 Inner Leaf 100 to 115 750 - 1500 Max UDL Depth kn mm 20 129 Weight kg/m 8.6 1650 - 2100 20 137 10.7 2250 - 2700 25 166 11.8 2850 - 3300 30 188 14.9 Length Range mm CB 150 STANDARD DUTY 750 - 2100 60 225 21.7 2250 - 2700 60 225 21.7 2850 - 3000 55 225 21.7 Max UDL Depth kn mm Weight kg/m 750 - 1500 20 115 8.6 1650 - 2100 20 118 10.7 2250 - 2700 25 152 11.8 2850 - 3300 30 174 14.9 Not recommended for the support of P.C.Concrete floors Not recommended for the support of P.C.Concrete floors HS 130 350 to 370 Cavity Length Range mm CB 130 We recommend the use of an additional cavity tray with all external cavity wall lintels HS 150 HEAVY DUTY 750 - 2100 60 225 21.7 2250 - 2700 60 225 21.7 2850 - 3000 55 225 21.7 3300 - 3900 50 225 21.7 3300 - 3900 50 225 21.7 4200 - 4500 40 225 21.7 4200 - 4500 40 225 21.7 4800 35 225 21.7 4800 35 225 21.7 5100 25 225 21.7 5100 25 225 21.7 750 - 2100 100 225 34.7 750 - 2100 100 225 34.7 2250 - 3300 80 225 34.7 3600 - 4200 70 225 34.7 2250 - 3300 80 225 34.7 3600 - 4200 70 225 34.7 HDX 150 EXTRA HEAVY DUTY 4500 - 4800 60 225 34.7 4500 - 4800 60 225 34.7 5100 45 225 34.7 5100 45 225 34.7 Versions also available for 125 to 140 inner leaf Versions also available for 125 to 140 inner leaf Denotes Plaster Key 18 Denotes Plaster Key 19 Cavity Walls Cavity Walls We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width Outer Leaf Cavity Inner Leaf 275 to 310 STANDARD DUTY Overall Width 100 Outer Leaf 50 to 70 Cavity 125 to 140 Length Range mm CB 50/130 We recommend the use of an additional cavity tray with all external cavity wall lintels 750 - 1200 Inner Leaf Max UDL Depth kn mm 15 108 Weight kg/m 5.9 1350 - 1500 15 108 7.4 1650 - 1800 20 140 8.5 295 to 330 100 70 to 90 125 to 140 Length Range mm CB 70/130 STANDARD DUTY Max UDL Depth kn mm Weight kg/m 750 - 1200 15 100 7.6 1350 - 1650 20 128 10.3 1800 - 2400 22 140 12.5 1950 - 2400 22 148 10.4 2550 - 2850 30 177 14.3 2550 - 2850 26 177 11.6 3000 - 3900 26 192 15.0 3000 - 3900 26 185 Not recommended for the support of P.C.Concrete floors 13.9 Not recommended for the support of P.C.Concrete floors HS 50/130 HEAVY DUTY HDX 50/130 EXTRA HEAVY DUTY 750 - 1200 60 225 16.5 1350 - 2100 60 225 18.0 2250 - 2700 60 225 19.5 HS 70/130 HEAVY DUTY 750 - 1200 60 225 16.5 1350 - 2100 60 225 18.0 2250 - 2700 60 225 19.5 2850 - 3000 55 225 19.5 2850 - 3000 55 225 19.5 3300 - 3900 50 225 19.5 3300 - 3900 50 225 19.5 4200 - 4800 40 225 19.5 4200 - 4800 40 225 19.5 5100 25 225 19.5 5100 25 225 19.5 750 - 2100 100 225 34.5 750 - 2100 100 225 34.5 2250 - 3300 80 225 34.5 3600 - 4200 70 225 34.5 2250 - 3300 80 225 34.5 3600 - 4200 70 225 34.5 HDX 70/130 EXTRA HEAVY DUTY 4500 - 4800 60 225 34.5 4500 - 4800 60 225 34.5 5100 45 225 34.5 5100 45 225 34.5 Denotes Plaster Key 20 Denotes Plaster Key 21 Cavity Walls Cavity Walls We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width Outer Leaf Cavity Inner Leaf 315 to 350 STANDARD DUTY Overall Width 100 Outer Leaf 90 to 110 Cavity 125 to 140 Length Range mm CB 90/130 We recommend the use of an additional cavity tray with all external cavity wall lintels 750 - 1200 Inner Leaf Max UDL Depth kn mm 15 90 Weight kg/m 7.6 1350 - 1650 20 118 10.3 1800 - 2400 22 130 12.5 HEAVY DUTY 100 90 to 110 190 to 215 Length Range mm HS 90/200 HEAVY DUTY Max UDL Depth kn mm Weight kg/m 750 - 1350 60 225 22.4 1500 - 2100 60 225 27.2 2250 - 3300 60 225 31.0 2550 - 2850 30 167 14.3 3600 - 4800 50 225 32.6 3000 - 3900 26 182 15.0 5100 35 225 32.6 Not recommended for the support of P.C.Concrete floors HS 90/130 380 to 425 750 - 1200 60 225 16.5 1350 - 2100 60 225 18.0 2250 - 2700 60 225 19.5 Versions also available for other cavity widths SX 90 HEAVY DUTY 750 - 4200 90 212 40.9 4500 - 4800 80 212 40.9 5100 - 5400 70 212 40.9 2850 - 3000 55 225 19.5 5700 65 212 40.9 3300 - 3900 50 225 19.5 6000 55 212 40.9 4200 - 4800 40 225 19.5 6300 50 212 40.9 5100 25 225 19.5 6600 45 212 40.9 Versions also available for other cavity widths. To achieve above loads lintels should be laterally restrained and propped during installation. HDX 90/130 EXTRA HEAVY DUTY 750 - 2100 100 225 34.5 2250 - 3300 80 225 34.5 3600 - 4200 70 225 34.5 4500 - 4800 60 225 34.5 5100 45 225 34.5 XHD 90 EXTREME DUTY 750 - 4200 120 240 56.6 4500 - 4800 100 240 56.6 5100 - 5400 90 240 56.6 5700 - 6600 65 240 56.6 Versions also available for other cavity widths. To achieve above loads lintels should be laterally restrained and propped during installation. Note: This lintel is supplied uninsulated. If required this should be carried out on site. Denotes Plaster Key 22 Denotes Plaster Key 23 Cavity Walls Attic Truss (Stonework) Supports attic trusses in open eaves condition We recommend the use of an additional cavity tray with all external cavity wall lintels Overall Width 320 to 350 Overall Width Outer Leaf 125 to 150 Outer Leaf Cavity Inner Leaf 95 to 110 100 to 115 Length Range mm 750 - 1500 CB 125/90/100 MEDIUM DUTY Cavity Inner Leaf Max UDL Depth kn mm 25 150 Weight kg/m 9.5 1650 - 2400 30 190 13.9 2550 - 3000 30 210 17.0 250 to 285 100 50 to 70 100 to 115 Length Range mm AT 50 HEAVY DUTY Max UDL Depth kn mm Weight kg/m 750 - 1800 35 150 9.8 1950 - 2400 35 150 12.2 2550 - 2700 35 150 14.7 750 - 1800 35 150 9.8 1950 - 2400 35 150 12.2 2550 - 2700 35 150 14.7 750 - 1800 35 150 9.8 1950 - 2400 35 150 12.2 2550 - 2700 35 150 14.7 Not recommended for the support of P.C.Concrete floors Versions are also available for other cavity widths HS 125/90/100 HEAVY DUTY 750 - 2100 60 225 17.7 2250 - 3300 50 225 17.7 3600 - 4200 40 225 19.0 4500 - 4800 35 225 19.0 Overall Width Outer Leaf 270 to 305 100 Versions also available for other cavity widths Cavity Inner Leaf Eaves AT 70 (Closed) Cavity Inner Leaf Cavity Inner Leaf 100 to 115 50 to 90 100 to 115 750 - 1200 CB EV 50 CB EV 90 HEAVY DUTY 70 to 90 15 103 5.2 1350 - 1500 15 103 6.4 1650 - 1800 20 131 7.4 1950 - 2100 20 138 7.6 2250 - 2700 26 192 11.3 Overall Width Outer Leaf Cavity 90 to 130 Inner Leaf 100 to 115 750 - 2100 20 160 7.9 2250 - 2700 20 185 13.0 AT 90 HEAVY DUTY 290 to 325 100 90 to 110 100 to 115 Denotes Plaster Key 24 Denotes Plaster Key 25 100 Internal Walls 200-215 Solid Walls Plastered both sides Lintels can be supplied insulated (extra charge) Length Range mm SB 100 STANDARD DUTY SB 100 HD HEAVY DUTY SB 100 HDX Max UDL Depth kn mm 750 - 1500 15 73 Weight kg/m 5.1 1650 - 1800 20 140 6.6 1950 - 2700 20 140 8.3 Length Range mm SBL 200 MEDIUM DUTY Max UDL Depth kn mm Weight kg/m 750 - 1500 20 142 9.0 1650 - 2100 20 142 10.1 2250 - 2700 20 142 11.3 2850 - 3600 25 215 11.2 2850 - 3000 25 218 13.8 3900 - 4500 30 215 16.8 3300 - 3600 40 219 17.2 4800 28 215 16.8 3900 - 4500 35 220 20.3 5100 24 215 16.8 4800 30 220 20.3 5100 28 215 20.3 750 - 1500 25 140 6.6 1650 - 2700 40 215 14.0 2850 - 3600 45 215 16.8 750 - 1500 60 140 11.5 1650 - 2700 60 215 16.8 Can be supplied pre-insulated at small extra charge OB 190 MEDIUM DUTY 750 - 1500 9 90 5.7 1650 - 2100 12 95 9.3 2250 - 2550 20 160 10.2 2700 - 3000 20 160 12.2 EXTRA HEAVY DUTY 140 Internal Walls DC 200 Plastered both sides SB 140 STANDARD DUTY SB 140 HD HEAVY DUTY 750 - 2100 25 140 8.2 2250 - 2700 25 140 10.2 2850 - 3600 25 215 13.0 3900 - 4200 45 215 19.5 4500 - 4800 35 215 19.5 5100 28 215 19.5 750 - 1500 35 140 10.2 1650 - 2700 40 215 16.3 2850 - 3600 45 215 19.5 HEAVY DUTY DC 200 HDX EXTRA HEAVY DUTY SB 140 HDX EXTRA HEAVY DUTY 750 - 1500 60 140 14.5 1650 - 2700 60 215 19.5 750 - 2100 60 225 15.3 2250 - 3000 50 225 15.3 3300 - 3900 50 225 18.4 4200 - 4800 30 225 18.4 750 - 2100 100 225 31.1 2250 - 3900 60 225 31.1 4200 - 4800 50 225 31.1 5100 30 225 31.1 Note: Max UDL figures may reduce if end bearings are less than 150mm. If in doubt check Technical Department Denotes Plaster Key 26 Denotes Plaster Key 27 100 External Walls Length Range mm MBL LIGHT DUTY Lintels above 1500 long should be propped. See notes opposite LA MEDIUM DUTY Lintels above 1500 long should be propped. See notes opposite EV 100 HEAVY DUTY Lintels above 3000 long should be propped. See notes opposite 750 - 900 Timber Frame Max UDL Depth kn mm 2 Weight kg/m 50 2.4 1050 - 1350 4 80 2.7 1500 - 2100 5 85 4.7 Use in lightly loaded locations such as meter boxes, garage personnel doors etc. Length Range mm TF 50 Weight kg/m 750 - 2100 8 185 4.6 2250 - 3000 10 185 5.9 3300 - 3900 10 185 7.0 Versions also available for other cavity widths Pinch batten must be used with TF 50 lintels 750 - 1500 6 90 4.5 1650 - 1800 6 119 5.3 1950 - 2400 10 158 6.2 2550 - 3000 13 215 7.5 3300 - 3900 8 215 7.5 TF 50 HD with cavity closer 750 - 2100 12 185 8.8 2250 - 300 15 185 10.1 3300 - 4800 10 185 11.2 Versions also available for other cavity widths Use to carry outer leaf and provide support for cavity tray where inner leaf is existing or supported separately. 750 - 1500 15 150 5.2 1650 - 2100 20 150 7.7 2250 - 3000 15 225 9.6 3300 - 4800 20 225 15.5 Lintels above 1200 long should be propped until lintel is fully loaded and brickwork has matured. Use horizontal timber spreader to avoid distorting lintel. Use single central prop for openings up to 2100. For larger openings use multiple props (max spacing 1200). Restraining clips (supplied) should be fixed to timber frame using 3 No 3.3mm Dia x 50 long galvanised nails. Clip should overlap lintel by 12mm as indicated by line on clip. Pinch batten must be used with TF 50 lintels 28 Max UDL Depth kn mm 29 Internal Walls Accessories Non load bearing Length Range mm 900 - 1200 INT 100 Max UDL Depth kn mm 5 Weight kg/m 20 1.9 LIGHT DUTY 750 - 2100 INT 100 HD 10 50 MEDIUM DUTY Supports arched soldier course over standard door and window openings. Can be used with all standard external wall lintels. Semicircular Arches Outer Leaf Cavity Inner Leaf Lintel Reference Opening Width Rise Span Opening Width Rise 475 450 - 500 75 2125 2100 - 2150 150 625 600 - 650 75 2225 2200 - 2250 150 675 650 - 700 75 2375 2350 - 2400 150 775 750 - 800 75 2425 2400 - 2550 150 925 900 - 950 75 1025 1000 - 1050 75 1075 1025 - 1100 75 1125 1100 - 1150 75 1225 1200 - 1250 75 1375 1350 - 1400 75 1525 1500 - 1550 75 1675 1650 - 1700 75 1775 1750 - 1800 75 1925 1900 - 1950 150 3.3 ARCHFORM Overall Width Span 275 to 315 100 75 to 100 Lengths Available SOFFIT COVER 100 to 125 900 Max UDL Weight Opening Radius Length kn kg mm mm mm SC600 20 10 600 300 900 SC 630 20 11 630 315 930 SC 900 20 15 900 450 1200 SC 915 20 15 915 457.5 1215 SC 1200 20 20 1200 600 1500 SC1500 20 25 1500 750 1800 1200 1500 1800 2100 Manufactured from UPVC, the soffit cover fits over the front flange of standard lintels to provide an aesthetically pleasing finish to the exposed soffit of the lintel. Available in white only. 2400 2700 4500 Other sizes and cavity widths can be made to order Lengths Available RENDER KEY 900 SLEEVE 1200 1500 1800 2100 140 wide mesh to inner leaf A separate shaped cavity tray should be used with all semicircular lintels This heavier gauge version of the soffit cover has keying ribs on the underside to accept a rendered finish, thus avoiding the need for special lintels, and the Health & Safety implications of welded mesh. 2400 2700 4500 Denotes Plaster Key 30 31 The Birtley The Birtley BAY 6 BAY 6 The easy way to support cavity walls above corner windows, bay windows etc. Bay 6 system is designed to support vertical loads only in standard duty loading conditions i.e. normal domestic construction with timber floor loads. Corner Window Support System Corner Window Support System • Uses standard components available ex-stock • Easy to transport and handle Bay 6 system can be used for sun lounges on the basis that separate provision is made for horizontal or windloads by structural engineer. • No special drawings or design work needed • Suits most standard wall constructions Maximum vertical load per support post : 10kn. • Hot-dip galvanized after fabrication System is intended for use in domestic loading conditions with timber floors and roofs. Do not use to support pre-cast concrete floors. If in doubt contact technical department for advice. Standard ex-stock lintels have hole punched in each end of rear flange for galvanizing purposes, this locates over dowel on top plate of post cap part number description P1645 support post - 1645 long recommended lintel 9 P3000 support post - 3000 long T90/250 90° cap plate - 250-270 walls CB50 14 8 T90/270 90° cap plate - 270-290 walls CB70 8 T90/290 90° cap plate - 290-310 walls CB90 8 T135/250 135° cap plate - 250-270 walls CB50 7 T135/270 135° cap plate - 270-290 walls CB70 7 T135/290 135° cap plate - 290-310 walls CB90 7 S10 spacer shim - 10 deep All measurements are shown in millimetres. Cap plate manufactured in 6 types, to suit 90˚ and 135˚ angles, and for 50, 70, and 90 cavity widths, 150 long spigot on underside locates into post Spacer shims for height adjustment Post stocked in two lengths, 1645 long for below sill fixing and 3000 long for fixing at foundation level (cut to required length on site) 48.3 dia x 5 circular section allows post to be rotated to desired position All components are hot-dip galvanized after fabrication to BS1461. With baseplate set 10mm from face of wall, post sits in cavity immediately behind outer leaf. This is the optimum position to accommodate post within junction of window frames. Unique baseplate shape allows use with 90˚ and 135˚ angles and 50 to 100 cavity widths All measurements are shown in millimetres. 32 weight (kg) 33 Note: Due to manufacturing limitations and tolerances, it is possible that in some instances the locating dowels may not quite line up with the punched holes in lintels. If this occurs please open up or re-drill holes in lintels. This will not affect the structural performance of the product. Fax Back Fax Back Please fill in required dimensions and fax to 0191 411 2558 Please fill in required dimensions and fax to 0191 411 2558 Semicircular Arch Apex Lintel PLASTER/RENDER REQUIREMENT. Please tick: No Mesh Half Mesh Full Mesh WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. PLASTER/RENDER REQUIREMENT. REMARKS Please tick: No Mesh Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. Fax back to WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. PLASTER/RENDER REQUIREMENT. Half Mesh Full Mesh Full Mesh REMARKS Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. Extended Semicircular Arch Please tick: No Mesh Half Mesh Arched Lintel Fax back to WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: Name Company LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. Project Fax No PLASTER/RENDER REQUIREMENT. REMARKS Please tick: No Mesh Half Mesh Full Mesh Project Fax No Telephone Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. e mail Gothic Arch e mail Three-Centred Lintel PLASTER/RENDER REQUIREMENT. Please tick: No Mesh Company REMARKS Telephone Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. Name Half Mesh Full Mesh WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: WALL CONSTRUCTION Outer Leaf: Cavity Width: Inner Leaf: LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. LOADING CONDITIONS Unless stated otherwise, we will select a steel thickness which will give the following safe loads. Up to 2100 long 20Kn 2100 to 3000 long 30Kn Above 3000 long Check with technical dept or supply working drawings. REMARKS Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. MARY AVENUE, BIRTLEY, CO.DURHAM DH3 1JF Telephone: 0191 410 6631 General Fax: 0191 410 0650 Sales: 0191 410 0132 Technical: 0191 411 2558 e mail: [email protected] Internet: www.birtley-building.co.uk www.lintels.com 34 PLASTER/RENDER REQUIREMENT. Please tick: No Mesh Half Mesh Full Mesh REMARKS Lintel is hot-dip galvanized after manufacture. Minimum coating weight 920G/M2 (Inc. both sides). We recommend the use of an additional damp proof tray with this lintel. MARY AVENUE, BIRTLEY, CO.DURHAM DH3 1JF Telephone: 0191 410 6631 General Fax: 0191 410 0650 Sales: 0191 410 0132 Technical: 0191 411 2558 e mail: [email protected] Internet: www.birtley-building.co.uk www.lintels.com 35