Eurocode 4 - 1.2 composite structures
Transcription
Eurocode 4 - 1.2 composite structures
EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop Some Information on Eurocode 4 – part 1.2 (mainly from DIFISEK project report) Joël KRUPPA CTICM Coordinator CEN TC 250 / Horizontal Group "FIRE" 1 EUROCODES Background and Applications Composite slabs & beams Options Brussels, 18-20 February 2008 – Dissemination of information workshop 2 Flat concrete slab or composite slab with profiled steel sheeting Shear connectors Profiles with or without Fire protection material slabs Reinforcing bar Shear connectors Optional slab Stirrups welded to web of profile Reinforcing bar beams Composite columns Options EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop (a) (b) 3 (c) a: steel embedded in concrete (traditional approach) b: concrete between flanges (f.r. dependent on reinforcement) c: concrete filled SHS - without reinforcement with reinforcement (f.r. ca. 30 minutes or less) (f.r. dependent on reinforcement) EUROCODES Background and Applications Calculation procedure thermal response Composite elements Brussels, 18-20 February 2008 – Dissemination of information workshop Non-uniform temperature distribution Load bearing and (possibly) separating function ¾ Load bearing capacity ¾ Thermal insulation ¾ Integrity Options ¾ tabulated data ¾ simple calculation model ¾ advanced calculation model 4 EUROCODES Background and Applications Tabulated data (steel and concrete composite members) Brussels, 18-20 February 2008 – Dissemination of information workshop Composite beams Slab Concrete for insulation 5 Composite columns EUROCODES Background and Applications Tabulated data and relevant parameters (composite columns – prEN1994-1-2) Brussels, 18-20 February 2008 – Dissemination of information workshop ef As h Ac us ew b us Standard Fire Resistance R30 R60 R90 R120 Minimum ratio of web to flange thickness ew/ef 1 Minimum cross-sectional dimensions for load level 1.1 1.2 1.3 minimum dimensions h and b [mm] minimum axis distance of reinforcing bars us [mm] minimum ratio of reinforcement As/(Ac+As) in % 2 Minimum cross-sectional dimensions for load level 2.1 2.2 2.3 minimum dimensions h and b [mm] minimum axis distance of reinforcing bars us [mm] minimum ratio of reinforcement As/(Ac+As) in % 3 Minimum cross-sectional dimensions for load level 3.1 3.2 3.3 minimum dimensions h and b [mm] minimum axis distance of reinforcing bars us [mm] minimum ratio of reinforcement As/(Ac+As) in % Standard fire rating Load level 0,5 ηfi,t ≤ 0,28 160 - 200 50 4 300 50 3 400 70 4 ηfi,t ≤ 0,47 160 - 300 50 4 400 70 4 - ηfi,t ≤ 0,66 160 40 1 400 70 4 - - Section dimension Reinforcing steel Concrete cover 6 EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop Composite Beams 7 EUROCODES Background and Applications Totally encased steel sections Brussels, 18-20 February 2008 – Dissemination of information workshop 8 EUROCODES Background and Applications How to apply tabulated data in fire design (two different situations) Brussels, 18-20 February 2008 – Dissemination of information workshop VERIFICATION PRE-DESIGN Rd of θ20°C Efi.d and Ed Efi.d ηfi,t = Efi.d / Ed ηfi,t = Efi.d / Rd Standard fire rating Section dimension reinforcing steel concrete cover Section dimension reinforcing steel concrete cover Standard fire rating Rd ≥ E d 9 EUROCODES Background and Applications Concrete with only insulation function Brussels, 18-20 February 2008 – Dissemination of information workshop 10 EUROCODES Background and Applications Composite elements Calculation rules thermal response Brussels, 18-20 February 2008 – Dissemination of information workshop Similar to concrete elements Complications due to shape Simple calculation rules available 11 EUROCODES Background and Applications Thermal response composite elements Advanced model (illustration) Brussels, 18-20 February 2008 – Dissemination of information workshop 12 1200 temperature [°C] Temperatuur [0 C] ==> G computer simulation 1000 A F E B D C B A 800 C 600 D 400 E F 200 G 0 0 30 60 90 120 time [min] Tijd [min] ==> test vs. simulation EUROCODES Background and Applications Composite elements Simple calculation models thermal response Brussels, 18-20 February 2008 – Dissemination of information workshop Semi-empirical approach Parameter study based on systematic calculation with advanced calculation model Direct application of advanced calculation model 13 Simple calculation models Semi-empirical approach EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 14 b Z ef u1 Y bc,fi h h w,fi u2 bc,fi ew Reduced cross section Components cross section: flanges steel section web steel section concrete re-bars For each component: reduced strength and/or reduced area Simple calculation models Parameter study approach EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 15 ¾ Composite slabs with profiled steel sheet Decking type re-entrant (6x) trapezoidal (49x) (LWC) Concrete depth HB [mm] 50, 60, 70, 80, 90, 100, 110, 120 Concrete type NCW and LWC ENV 1994-1-1 standard fire conditions profiled shape deckings taken into account thermal properties according to EC average moisture content: 4% (NWC) and 5% Note: total number of simulations: 880 EUROCODES Background and Applications Typical temperature distribution at the unexposed side of a composite slab Brussels, 18-20 February 2008 – Dissemination of information workshop 16 temperature [°C] Insulation criterion: average -ΔΘav ≤ 140 ºC -ΔΘ max ≤ 180 ºC Composite slabs Thermal insulation (illustration) EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 17 Issues: h1 tf = tf (l1, l2, …, A/Lr, φ) h2 l3 l2 l1 A Lr with: l1, l2, .. A Lr φ geometry slab volume rib exposed surface rib configuration factor tf = a0 + a1·h1 + a2· φ + a3·A/Lr + a4·1/L3 + a5·A/Lr·1/l3 [min] with: ai coefficients, depending on duration of s.f.c. exposure Thermal insulation composite slabs Verification simple calculation rule EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 1.25 Unsafe Fire resistance (new rule) Fire resistance (adv. model) Fire resistance (Eurocode 4) Fire resistance (adv. model) . [-] ==> . [-] ==> 1.50 1.00 Safe 0.75 0.50 30 60 90 120 μ 0.962 σ 0.148 150 180 210 18 1.50 1.25 Unsafe 1.00 Safe 0.75 0.50 30 60 90 120 μ 1.015 σ 0.073 150 180 210 Fire resistance (adv. model) [min] ==> Fire resistance (adv. model) [min] ==> (a) ENV rule (b) new rule Composite slabs Thermal response positive reinforcement EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 19 compression zone concrete (20 °C) z u2 u3 u1 Temperature reinforcement has significant impact on M+p,Θ Θr = Θr (u1 , A/O, l3, z ..) z = z(u1, u2,u3) Note: steel sheet may significantly contribute to the load bearing capacity! EUROCODES Background and Applications Thermal response positive reinforcement Simple calculation rule Brussels, 18-20 February 2008 – Dissemination of information workshop 1.50 1 /2L3 u1 O α A Temperature (EC 4) Temperature (adv. model) /2L3 H safe 1.25 1 Temperature (new rule) . Temperature (adv. model) [-] ==> . [-] ==> 1.50 20 1.00 unsafe 0.75 0.50 350 450 μ 0.913 σ 0.082 550 650 750 u1 O α A 1.00 unsafe 0.75 0.50 350 450 μ 0.981 σ 0.032 550 650 0 0 Temperature (adv. model) [ C] ==> (a) ENV rule H safe 1.25 Temperature (adv. model) [ C] ==> (b) new rule 750 EUROCODES Composite slabs Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop h3 h1 h2 heff l2 l1 21 h3 h1 h2 l3 l1 l3 chape béton tôle d'acier l2 Thermal Insulation (ISO fire) I 30 Equivalent thickness heff[mm] 60 – h3 I 60 80 – h3 I 90 100 – h3 I 120 120 – h3 EUROCODES Background and Applications Concrete filled SHS columns Resistance to fire (traditional approach) Brussels, 18-20 February 2008 – Dissemination of information workshop Design charts available Unpractical Need for “user friendly” design tool ⇒ e.g. POTFIRE no. concrete rebar quality 1 C20 2 C20 3 C20 4 C30 5 C30 6 C30 7 C40 8 C40 9 C40 % 1.0 2.5 4.0 1.0 2.5 4.0 1.0 2.5 4.0 22 EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop input POTFIRE In- & output output 23 Validation POTFIRE EUROCODES Background and Applications temperature test Brussels, 18-20 February 2008 – Dissemination of information workshop 24 1100 assumptions: 1000 - αconv = 25 W/m2k 900 800 - εres 700 = 0.7 600 500 400 Concrete Filled Steel Hollow Section 300 200 100 0 0 100 200 300 400 500 600 700 800 900 1000 1100 temperature (Potfire) EUROCODES Background and Applications Logiciels de calcul Brussels, 18-20 February 2008 – Dissemination of information workshop Logiciels « AFcolumn » et « AFbeam » Développés par ProfilARBED Peuvent être obtenus sur le site www.arcelormittal.com 25 EUROCODES Background and Applications Simple calculation model (steel and composite members) Brussels, 18-20 February 2008 – Dissemination of information workshop Beams (steel or composite) 26 Columns EUROCODES Background and Applications Simple calculation model (composite beam) - plastic resistance theory Brussels, 18-20 February 2008 – Dissemination of information workshop 27 Concrete slab S1 Steel section Connector S1 Section S1 + Fc - D+ + + Ft Section geometry Temperature distibution Stress distribution Moment resistance + Mfi,Rd+ = Ft × D + EUROCODES Background and Applications Composite beams Brussels, 18-20 February 2008 – Dissemination of information workshop 28 b eff hc b2 e2 ew h hw e1 b1 ¾bare 3 0 m in température [°C] 1000 800 1 5 m in 600 400 200 0 0 100 200 300 400 500 fa c te u r d e m a ssive té [m -1] ¾insulated 15 m m 1000 l'acier [°C] température de E C H A U F F E M E N T : 9 0 m in . 20 m m 800 600 400 25 m m 30 35 40 45 50 55 200 0 0 100 200 300 400 fa c te u r d e m a s s iv e té ( S / V e n m - 1 ) m m m m m m EUROCODES Background and Applications Simple calculation model (composite column) - buckling curve Brussels, 18-20 February 2008 – Dissemination of information workshop P Aai Acj Lfi Z 1.0 χ(λθ) Y 0.5 Ask 0 Effective section Appropriate buckling curve Load capacity: Nfi.Rd = χ(λθ) Nfi.pl.Rd χ(λθ) ⇐ strength and rigidity of effective section + column buckling length Lfi λθ 29 Construction details shall be respected in order to EUROCODES Background and Applications consistent with numerical models Brussels, 18-20 February 2008 – Dissemination of information workshop Reinforcing bars between slab and edge columns φ12 in S500 Maximum gap of 15 mm between beam and column and between lower flange of the beam gap gap ≤ 15 mm 30 EUROCODES Background and Applications Construction details to get hogging moment resistance in fire situation Brussels, 18-20 February 2008 – Dissemination of information workshop Join detail - Example Continuous reinforcing bar studs gap Sections with infilled concrete A limited gap allowing to develop a hogging moment in the fire situation 31 EUROCODES Background and Applications Construction details for connection between concrete and steel Brussels, 18-20 February 2008 – Dissemination of information workshop Connection between steel profile and encased concrete φr ≥ 8 mm φs ≥ 6 mm welding aw ≥ 0,5 φs hν studs d ≥ 10 mm hν ≥ 0,3b lw ≥ 4 φs φr ≥ 8 mm b Welding of stirrups to the web Welding of studs to the web 32 EUROCODES Background and Applications Fire design by global structural analysis Brussels, 18-20 February 2008 – Dissemination of information workshop Application requirement of advanced calculation models ¾requirement on material models • strain composition • kinematical material model • strength during cooling phase ¾step by step iterative solution procedure ¾check of possible failure untreated in direct analysis • rupture due to excessive steel elongation • cracking and crushing of concrete 33 EUROCODES Background and Applications Global analysis of steel and concrete composite floor under localised fire Brussels, 18-20 February 2008 – Dissemination of information workshop 34 Composite slab Steel deck: 0.75 mm Standard part of the floor system 3.2 m 4.2 m 15 m 10 m 15 m 10 m 10 m 15 m EUROCODES Background and Applications Choice of structural model Brussels, 18-20 February 2008 – Dissemination of information workshop Two different structural models may be adopted ¾2D composite frame model (beam elements) • membrane effect is limited to one direction due to 1D effect slab model • load redistribution is not possible between parallel beams ¾3D composite floor model (multi-type element) • membrane effect over whole floor area • load redistribution becoming possible with help of shell elements More realistic to apply 3D composite floor model 35 EUROCODES Background and Applications Validity of 3D composite floor model Test 3D calculation model 36 Hori. Disp. (mm) Vert. Disp. (mm) Brussels, 18-20 February 2008 – Dissemination of information workshop 0 0 15 Time (min) 30 45 60 75 -40 -80 -120 -160 Test Cal. 3D Cal. 2D -200 60 40 20 0 0 20 40 Time (min) 60 80 EUROCODES Background and Applications Strategy of 3D composite floor modelling Brussels, 18-20 February 2008 – Dissemination of information workshop 37 Fire area Global structure without composite slab Detail of numerical modelling EUROCODES Background and Applications Mechanical loading and boundary conditions Brussels, 18-20 February 2008 – Dissemination of information workshop 38 Uniformly distributed load: G + Ψ1,1Q θ=0 Continuity condition of concrete slab θ=0 Continuity condition of columns EUROCODES Background and Applications Mechanical response of the structure Brussels, 18-20 February 2008 – Dissemination of information workshop 39 ¾Total deflection of the floor and check of the corresponding failure criteria 140 mm 20 min 310 mm 40 min EUROCODES Background and Applications Mechanical response of the structure Brussels, 18-20 February 2008 – Dissemination of information workshop 40 ¾Total deflection of the floor and check of the corresponding failure criteria 110 mm ≤ L/20 = 500 mm 230 mm Deflection (mm) 0 - 50 -100 -150 -200 Main beam -250 -300 60 min Secondary beam 0 10 20 30 40 50 Time (min) 280 mm ≤ L/20 = 750 mm 60 EUROCODES Background and Applications Mechanical response of the structure Brussels, 18-20 February 2008 – Dissemination of information workshop 41 ¾Check of failure criteria: elongation of reinforcing steel 1.4 % ≤ 5 % 1.3 % ≤ 5 % Strain of reinforcing steel // slab span Strain of reinforcing steel ⊥ slab span EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop Unbraced frame – R + 3 42 EUROCODES Design Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 43 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 1.0 G + 0.3 Q 0.5 W 0.5 W 0.5 W Unbraced frame Edge column temperature EUROCODES Background and Applications Time : 90 minutes Brussels, 18-20 February 2008 – Dissemination of information workshop 44 955 926 845 750 671 606 553 510 475 448 428 413 405 403 405 413 428 448 475 510 553 606 671 750 845 926 955 Y X Temperature (°C) 956 927 847 753 675 611 558 516 482 455 435 420 412 409 412 420 435 455 482 516 558 611 675 753 847 927 956 957 929 851 759 683 621 570 529 496 469 449 435 426 423 426 435 449 469 496 529 570 621 683 759 851 929 957 958 931 855 767 694 636 589 550 517 491 471 457 448 446 448 457 471 491 517 550 589 636 694 767 855 931 958 960 934 860 775 707 655 614 578 546 518 498 485 477 474 477 485 498 518 546 578 614 655 707 775 860 934 960 963 937 866 782 714 674 654 619 578 551 532 519 511 509 511 519 532 551 578 619 654 674 714 782 866 937 963 966 941 873 791 718 683 680 654 614 590 573 561 554 552 554 561 573 590 614 654 680 683 718 791 873 941 966 969 947 884 807 729 686 683 674 655 637 623 613 607 606 607 613 623 637 655 674 683 686 729 807 884 947 969 973 954 901 835 770 729 718 714 707 695 685 677 672 671 672 677 685 695 707 714 718 729 770 835 901 954 973 1000 A External Column A 900 B 800 C 700 B 600 500 400 C 300 200 100 0 0 10 20 30 40 50 60 70 80 Time (min) 90 977 963 923 875 835 807 791 782 775 767 760 755 751 750 751 755 760 767 775 782 791 807 835 875 923 963 977 981 972 950 923 901 884 873 866 860 855 851 848 846 845 846 848 851 855 860 866 873 884 901 923 950 972 981 983 980 972 963 954 947 941 937 934 931 929 927 926 926 926 927 929 931 934 937 941 947 954 963 972 980 983 983 983 981 977 973 969 966 963 960 958 957 956 955 955 955 956 957 958 960 963 966 969 973 977 981 983 983 Central column temperature EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 45 954 924 842 745 663 595 538 487 443 407 378 354 335 320 308 300 296 294 294 296 301 308 320 335 354 378 408 444 488 538 595 663 745 843 925 955 Y X 955 925 844 748 667 600 544 494 451 415 386 362 343 328 316 309 305 303 303 305 309 317 328 343 362 386 415 451 494 544 600 667 748 845 926 955 956 927 847 753 675 610 556 508 465 430 401 378 359 344 333 327 324 323 323 324 327 333 344 359 378 401 430 466 508 556 611 676 754 848 927 956 957 930 852 762 687 627 576 530 488 453 425 402 384 369 359 354 353 353 353 353 354 359 369 384 402 425 454 489 531 576 627 688 762 853 930 957 959 932 858 770 700 647 603 561 519 483 455 432 415 401 392 389 391 395 395 391 389 392 401 415 433 455 483 519 561 603 647 700 770 858 933 959 962 936 863 778 708 666 645 604 553 518 491 469 453 440 431 427 439 451 451 439 427 431 440 453 470 491 518 553 604 645 667 708 778 864 936 962 965 940 871 787 712 676 673 640 592 560 535 516 500 488 478 472 478 487 487 478 472 478 488 500 516 536 560 592 640 673 676 713 787 871 940 965 968 946 882 803 723 679 676 663 637 611 590 573 559 547 536 526 507 492 492 507 526 536 547 559 573 590 611 637 663 676 679 723 803 883 946 968 Temperature (°C) Central Column 1000 A 900 A 800 700 B B 600 D 500 D 400 300 C 200 100 0 0 10 20 30 40 50 60 70 80 90 Time (min) C 972 953 899 832 765 723 712 705 692 674 657 643 631 620 609 596 570 549 549 570 596 609 620 631 643 657 674 692 705 712 723 765 832 899 953 972 976 962 922 872 832 803 785 774 763 751 739 728 718 709 699 687 673 664 664 673 687 699 709 718 728 739 751 763 774 785 803 832 872 922 962 976 980 972 949 922 899 882 869 860 852 844 837 830 824 817 811 804 796 792 792 796 804 811 817 824 830 837 844 852 860 870 882 899 922 949 972 980 983 980 972 962 953 945 939 933 929 925 921 917 913 910 907 903 900 899 899 900 903 907 910 913 917 921 925 929 934 939 945 953 962 972 980 983 983 983 980 976 972 967 963 960 957 954 951 948 946 943 941 939 938 937 937 938 939 941 943 946 948 951 954 957 960 963 967 972 976 980 983 983 Bean-slab temperature EUROCODES Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 38 41 44 49 54 61 66 66 68 72 76 81 86 92 99 107 118 131 147 165 185 209 236 266 301 340 383 433 489 552 624 705 799 860 39 41 45 49 54 61 66 66 68 71 75 80 85 91 97 103 111 120 135 154 175 199 225 254 287 325 367 416 472 536 612 701 810 876 41 44 47 51 56 62 66 66 68 72 76 81 86 92 97 101 104 110 125 145 165 188 212 240 271 306 346 393 449 516 598 700 828 903 46 49 52 56 60 64 67 67 71 79 86 92 97 102 107 114 123 133 146 163 182 202 224 249 278 311 349 395 451 518 603 709 843 921 55 59 63 67 72 76 80 83 89 98 109 120 129 138 148 159 173 186 199 213 229 246 266 288 314 344 380 424 477 543 625 729 859 934 68 74 80 86 92 99 110 122 132 144 159 176 193 209 225 240 255 269 283 297 311 327 343 363 385 412 444 483 531 591 666 760 878 946 87 94 103 116 130 144 163 182 200 220 242 265 289 314 339 363 384 402 417 430 443 456 469 485 503 524 551 583 622 671 732 808 903 958 115 127 144 166 192 218 247 274 300 327 354 385 424 473 525 568 598 617 630 641 650 659 668 678 690 704 721 741 766 797 835 881 937 969 143 162 187 217 251 289 329 367 400 432 463 495 534 627 750 815 836 847 855 860 864 868 872 876 881 887 894 902 912 925 940 957 971 977 168 191 222 260 307 361 419 471 512 546 576 603 624 46 195 224 262 310 373 454 570 645 679 721 745 762 771 230 266 315 378 461 575 753 270 315 374 449 546 673 849 294 344 407 485 582 703 861 300 352 416 494 590 709 865 302 354 418 496 592 710 865 303 354 418 496 592 711 865 303 354 418 496 592 711 865 303 354 418 496 592 711 865 Y X Temperature Beam (°C) 1000 A 900 800 D C 700 600 500 B 400 300 A 200 B C D 100 0 0 10 20 30 40 50 60 70 80 90 Time (min) EUROCODES Deformations of the frame Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 47 Horizontal displacement HD (mm) 160 140 120 100 80 60 40 20 0 0 10 20 30 40 50 60 Time (min) Y X HD 70 EUROCODES Braced frame Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 48 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q 1.0 G + 0.5 Q Braced frame EUROCODES Deformation of frame Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop 0 0 49 10 20 -50 -100 -150 -200 -250 -300 -350 VD -400 Vertical displacement VD (mm) Y X 30 40 Time (min) 50 60 EUROCODES Comparison Background and Applications Brussels, 18-20 February 2008 – Dissemination of information workshop N ° o f ca se a se 1 R e s tr a in t c o n d itio n u n b ra ced φ 16 u n b ra ced 200 φ20 o f b ea m m in u te s 4 4 .5 280 300 m in u te s 300 200 φ20 6 0 .5 280 300 m in u te s 300 200 φ20 200 F ir e r e s is ta n o f th e fra m 3 7 .5 280 300 φ 16 300 u n b ra ced d im e n s io n 300 200 200 a se 3 d im e n s io n o f c e n t r a l c o lu m n 200 200 a se 2 50 d im e n s io n o f e x t e r n a l c o lu m n φ20 1000 a se 4 300 u n b ra ced 200 a se 5 φ20 b ra ced 200 φ 16 4 7 .5 280 300 m in u te s 300 200 6 4 .0 m in u te s 300 φ20 200 200 70 269 300 φ 16 1000 a se 6 200 b ra ced 200 70 269 300 φ 16 200 φ 16 300 6 0 .0 m in u te s