Product information PI 62 Disk-type tool turret
Transcription
Product information PI 62 Disk-type tool turret
Product information PI 62 Disk-type tool turret with integrated tool direct drive series 2013-08-29 0.5.437.2xx 0.5.437.6xx ® Table of Contents Disk-Type Tool Turret Series 0.5.437.2xx / .6xx with Tool direct drive Description .............................................................................................................. 4 Technical Data ........................................................................................................ 6 Admissible Loads.................................................................................................... 8 Dimensions ........................................................................................................... 10 Precision ............................................................................................................... 18 Fluid Rotary Feed-Through................................................................................... 18 Performance Data for the Tool Coupling .............................................................. 20 Dimensions ........................................................................................................... 21 Type Key ................................................................................................................. 22 Ordering Details .................................................................................................... 23 You can request projection instruction PA 62. Note: The information contained in this Product Information is in conformity with knowledge at the point of printing. We reserve the right to perform modifications within the framework of continuous further development. PI_62_en_2013-08-29.fm PI 62 3 ® Series 0.5.437.2xx / .6xx Description Disk-Type Tool Turret Series 0.5.437.2xx / .6xx witht Tool direct drive Description These turrets are suitable for use on high-capacity turning machines for forward as well as equipollent reverse machining. They are equipped with all of the features and functions of modern high-performance and high-capacity tool turrets. Their robust design and short switching times mean they are also very well suited for heavy-duty use in series manufacture and very suitable for highest productivity for milling and drilling Features Two-motor Technology One inetegrated indexing drive and the tool drive share one motor Direct drive, high cutting speeds up to 12.000 rpm and highest milling power Highest degree of stability due to high locking forces hydraulic locking with special triple generating Hirth-type gear Not affected by collisions due to: Low kinetic energy of the indexing drive Fastening snap-ring groove for the tool disk Directly controllable with machine controller Cooling lubricant pressure up to 50 bar (Standard) Options: Central rotary feed-through for example for fluid-actuated tools highpressure cooling lubricant device, ... 4 PI 62 ® Series 0.5.437.2xx / .6xx Description 3 1 2 4 5 6 7 8 9 11 1 2 3 4 5 6 7 8 9 10 11 1) 10 1) Turret housing Tool disk Motor for tool drive Connection cooling lubricant Connection hydraulic turret lock and unlock Motor for indexing drive Connection elektric Connection air sealing turret Connection air sealing driven tool Connection cooling motor Connection hydraulic engaged and disengaged1) Only for 0.5.437.2xx PI 62 5 ® Series 0.5.437.2xx / .6xx Technical data indexing drive Technical data indexing drive Size Series Disk-type tool turret 0.5.437.2xx 16 8 Number of switching positions 12 20 16 8 12 Admissible tangential load (turret locked)1) kNm 1,8 3,6 Admissible mass moment of inertia of tools1)2) with tool disk and holder kgm2 3,2 6,3 Nm 32 63 Admissible out of balance (load moment) due to tooling see chart page 7 min-1 Admissible rpm Admissible drive torque Gear ratio swivel drive Nm 10 10 i 54 72 Switching times3)4) Rotate tool disk:5) • incl. acceleration and braking per partial step 30° s 0,12 0,2 • without acceleration and braking per additional partial s 0,06 0,08 Turret unlock/lock -hydraulic s 0,12 0,13 Tool drive engage/disengage -hydraulic s 0,08 0,08 20 16 50 50 Adm. switching frequency3) (median switching angle m =90°) Operating pressure Hydraulic ± 10% bar Cooling lubricant • standard bar 5 - 50 (filtering < 50µm)6) • High-pressure cooling lubricant device bar 150 cm3 30 45 Turret (incl. drive motor)6) Tool disk and tooling (adm) kg 125 160 kg 80 Adm. ambient temperature °C (filtering < 25µm)6) Fluid absorption volume Turret unlock/lock Mass 1) Higher values on request 2) Switching times on request 3) Conditions: - Fluid supply sufficiently large - Turret up to operating temperature - Without controller-related non-productive time - Switching times are dependent on mass moment of rotor - Further details see motor chart. 4) The swivel times are determined with an average load. Further details on request. calculation speed 4500 rpm 5) At design standard housing 6) Ensure compliance with the required filter fineness for the tools used. For example spindle heads with internal cooling lubricant supply. 6 PI 62 160 10 ... 40 16 ® Series 0.5.437.2xx / .6xx Recommended motors for indexing drive Recommended motors for indexing drive protection class IP 67 shaft-side J Zul. driving kgm2 min-1 swiveling times for 30°-step without acceleration and braking s Size of turret 16 20 SAUTER control unit EK 600 0,0003 4000 0,07 0,09 SAUTER with rotary encoder activation1) 0,0003 4500 0,06 0,08 Siemens 1FK7043 HD1) 0,0001 6000 0,05 0,06 Siemens 1FK70421) 0,0003 4500 0,06 0,08 Fanuc 2/5000 / 2/50001) 0,0003 4500 0,06 0,08 Delta with control unit 0,0003 4000 0,07 0,09 Mitsubishi HF 75 0,00015 4500 0,06 0,08 1) controlled via machine controll system PI 62 7 ® Series 0.5.437.2xx / .6xx Admissible Loads Admissible Loads Note The diagrams refer to static loads. In case of impact load (interrupted cutting), significantly lower values must be reckoned with. +Fy -Fz +Fz +Fx r -Fy force + Fy tangential loading Size 20 Size 16 8 PI 62 ® Series 0.5.437.2xx / .6xx Admissible Loads a -Fz +Fz +Fx r force +Fx shunt loading leading edge is the basis for dimension a +Fz; -Fz force + Fx longitudinal loading +Fx size 20 size 16 a size 20 size 16 r PI 62 9 ® Series 0.5.437.2xx / .6xx Dimension block shape Dimension block shape (NH Standard 1) N H NH B Q Dargestellt Block-Gehäuse NH 125 L1 J E X D O P C V W W W W L2 10 PI 62 ® Series 0.5.437.2xx / .6xx Dimension block shape series size Disk-Type turret 0.5.437.2xx block shape (NH standard 1) 16 20 NH 100 125 B 200 238 C 266 250 D 122 125 E 28 35 H 38 41 J M10 M12 L 1) SAUTER-Motor with control unit EK 600 L1 on request 403 SAUTER drive with rotary encoder activation L1 on request 431 Delta-Motor with control unit L1 on request 487 Siemens 1 FK7 43/42 L2 365 3511) Fanuc 2 / 2 L2 350 3361) Mitsubishi HF 75 L2 on request 351 N 278 293 O 240 295 P 132 185 ØQ 252 270 V 73 65 W 34 40 X 28 35 Hint! plus motor length! PI 62 11 ® Series 0.5.437.2xx / .6xx Dimension block shape Dimension block shape N H NH B Q Dargestellt Block-Gehäuse NH 140 J L1 E X D O P C V W WWW L2 12 PI 62 ® Series 0.5.437.2xx / .6xx Dimension block shape series size Disk-Type turret 0.5.437.2xx block shape 16 20 NH 115 140 B 215 265 C 244 300 D 100 110 E 28 35 H 38 41 J M10 M12 L SAUTER-Motor with control unit EK 600 L1 on request 403 SAUTER drive with rotary encoder activation L1 on request 431 Delta-Motor with control unit L1 on request 487 Siemens 1 FK7 43/42 L2 365 351 Fanuc 2 / 2 L2 350 336 Mitsubishi HF 75 L2 on request 351 N 278 293 O 220 270 P 132 175 ØQ 252 270 V 60 65 W 34 40 X 28 35 PI 62 13 ® Series 0.5.437.2xx / .6xx Dimension L-shape Dimension L-shape (NH standard 1) N H NH B Q Dargestellt L-Gehäuse NH 125 J L1 X E T D O P C V W W W W L2 14 PI 62 ® Series 0.5.437.2xx / .6xx Dimension L-shape series size Disk-Type turret 0.5.437.2xx L shape (NH standard 1) 16 20 NH 100 125 B 200 236 C 266 250 D 122 125 E 28 35 H 38 41 J M10 M12 L SAUTER-Motor with control unit EK 600 L1 on request 418 SAUTER drive with rotary encoder activation L1 on request 446 Delta-Motor with control unit L1 on request 502 Siemens 1 FK7 43/42 L2 365 366 Fanuc 2 / 2 L2 350 351 on request 350 N O 295 P 240 185 ØQ 132 270 T 252 100 V 73 124 W 95 40 X 34 35 PI 62 15 ® Series 0.5.437.2xx / .6xx Dimension L-shape Dimension L-shape (NH standard 2) N H NH B Q Dargestellt L-Gehäuse NH 140 J L1 E X D T O P C V W W W W L2 16 PI 62 ® Series 0.5.437.2xx / .6xx Dimension L-shape series size Disk-Type turret 0.5.437.2xx L shape (NH standard 2) 16 20 NH 115 140 B 215 265 C 244 300 D 100 110 E 28 35 H 38 41 J M10 M12 L SAUTER-Motor with control unit EK 600 L1 on request 418 SAUTER drive with rotary encoder activation L1 on request 446 Delta-Motor with control unit L1 on request 502 Siemens 1 FK7 43/42 L2 365 366 Fanuc 2 / 2 L2 350 351 Mitsubishi HF 75 L2 on request 366 N 278 350 O 220 270 P 132 175 ØQ 252 270 T 73 100 V 95 124 W 34 40 X 28 35 PI 62 17 ® Series 0.5.437.2xx / .6xx Precision / Fluid-Drehdurchführung Precision / Fluid-Drehdurchführung Repeating accuracy (Multiple move to a switching position from the same direction) ± 1,6“ X mm x ----------------------- m 100 mm Indexing precision (Multiple move to a switching position from different direction) ± 4“ X mm x ----------------------- m 100 mm Fluid Rotary Feed-Through All turrets are deliverable with central fluid rotary feed-through: „uncontrolled“ version – fluid supply in all switching positions e.g.for gripper actuation, also for sealing air „controlled“ version – fluid supply in one switching defined positions e.g.for KSS, for automatic tool changes, and similar actions Up to five of supply lines are routed through the centre of the turret. Operating pressure Padm = 150 bar (standard). 18 PI 62 ® Series 0.5.437.2xx / .6xx Admissible duty cycle (DC) Admissible duty cycle (DC) Tool drive Performance Diagram Padm 10% DC*) Pnom 100% DC*) Power rpm nnom nadm 10% DC*) Madm 100% DC*) Mnom power rpm nnom nadm *) specifications for mode apply to 2 min for performance. PI 62 19 ® Series 0.5.437.2xx / .6xx Performance Data for the Tool Coupling Performance Data for the Tool Coupling Size 16 Series 20 0.5.437.216 0.5.437.616 0.5.437.220 0.5.437.220 200V1) 0.5.437.620 200V1) Performance data Drive rating2) Pnom/ Padm kW 7,5/ 10,5 7,5/ 10,5 10,4 / 18 7,6 / 12 4,7 / 5,3 Torque3) Mnom / Madm Nm 16,5 / 30 16,5 / 30 33 / 56 18 / 37 18 / 41 rpm1)4) nnom/ nadm min-1 5000 / 12000 5000 / 6000 3000 / 10000 4000 / 10000 2500 / 10000 1,0 1,0 1,0 1,0 1,0 Gear ratio 1) 2) 3) 4) 20 i=n1 / n2 VDClv (direct current link voltage), without specification VDClv = 600V The values are reference values for short-term operation. Higher rpm generate more heat and noise. Torque limitation at motor converter required! The torque values apply to smooth-machining (such as thread drilling). In the case of machining with severe shock loads (e.g. face milling and similar operations) it is necessary to reduce the motor drive torque by 50% or more Higher rpm on request PI 62 ® Series 0.5.437.2xx / .6xx Dimensions Dimensions selectable working position A 12°° 3°° d 9°° H SW Size Series Disk-type tool turret 0.5.437.2xx 16 20 16x0,8 20x0,8 A 87 100 H 38 41 d1) 30 40 310 340 Coupling profil DIN 54801) distance Tool holder receptacle system cylinder shaft DIN 10889 (DIN 69880) SW 1) - standard Further on request Series Size Disk-type tool turret 0.5.437.6xx 16 interface distance 20 BTM 55-short A 87 H 38 d 45 SW standard on request 340 PI 62 21 ® Type key Type key 0 . 5 . 4 37 . 2 2 0 Series 0.5.437 Disk-type tool turret with tool direct drive coupling process with spindle positioning Type of design 2 Tools with switchable coupling 6 Tools with unswitchable coupling Size 16 20 22 PI 62 ® Ordering Details Ordering Details Company: ++49 (0) 7123-926-190 Street: ++49 (0) 7123-926-0 Postcode, City: [email protected] Name: Sauter Feinmechanik GmbH Postfach 1551 D-72545 Metzingen Germany Phone: Fax: e-mail: SAUTER-Disk-type tool turret 0.5.437.2xx / .6xx Ordering details Possible configurations Your selection Basis turett Housing shape Size Number of switching positions Motor for indexing drive L / Block (NH 1/2) 16 / 20 8 / 12 / 16 SAUTER / Siemens / Fanuc / ... Installation position Radial tool drivel Working position Tool disc 3°° / 9°° / 12°° SW Special requirements: PI 62 23
Similar documents
Product information PI 43.2 Disk-type tool turret
Conditions: - Fluid supply sufficiently large - Turret up to operating temperature - Without controller-related non-productive time - Switching times valid for high dynamic motor (e.g. 1FK7043) - F...
More information