6 SYLVAN WAY, THIRD FLOOR PARSIPPANY, NEW JERSEY 07054
Transcription
6 SYLVAN WAY, THIRD FLOOR PARSIPPANY, NEW JERSEY 07054
ALTERATIONS TO: AVIS BUDGET GROUP 6 SYLVAN WAY, THIRD FLOOR PARSIPPANY, NEW JERSEY 07054 BLOCK: 202 LOT: 1.9 OCCUPANCY GROUP: B-BUSINESS BUILDING IS FULLY SPRINKLERED THERE IS NO CHANGE TO THE POSTED OCCUPANCY OR EGRESS. PROJECT DESCRIPTION THIS ALTERATION PROJECT INCLUDES SELECTIVE DEMOLITION OF NON STRUCTURAL ELEMENTS, CONSTRUCTION OF INTERIOR PARTITIONS, REMOVAL AND REPLACEMENT OF ACOUSTIC CEILING TILE, EXISTING GRID TO REMAIN, RELOCATION AND INSTALLATION OF NEW LIGHTING, AND RENOVATIONS TO THE EXISTING PANTRY AREAS.MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION WORK WILL BE ON A DESIGN BUILD BASIS. APPLICABLE CODES: INTERNATIONAL BUILDING CODE - NJ ED., 2009 NATIONAL ELECTRICAL CODE, 2011 NATIONAL STANDARD PLUMBING CODE, 2009 ASHRAE 90.1-2007 INTERNATIONAL MECHANICAL CODE, 2009 INTERNATIONAL FUEL GAS CODE, 2009 REHABILITATION SUBCODE - NJAC 5:23-6 BARRIER-FREE SUBCODE - NJAC 5:23-7 ANSI A117.1-2003 GENERAL NOTES: 1. COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC AUTHORITIES GOVERNING THE WORK. s t u d i o 1 2 0 0, LLC KEY SITE PLAN 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com LIST OF DRAWINGS: LEGEND: NTS AREA OF WORK 2. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES GOVERNING THE WORK. SHADED AREA NOT IN SCOPE (EXISTING TO REMAIN) 3. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION. 4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT & OWNER FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION. 5. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS AND OCCUPANTS. 6. TENANT WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION ARCHITECTURAL CVR PROJECT DESCRIPTION, GENERAL NOTES, SYMBOLS, & KEY SITE PLAN A-0 CLEARANCES & GENERAL MOUNTING HEIGHTS A-1A CONSTRUCTION/ DEMOLITION PLAN (A) - SHOWING FURNITURE & POWER A-1B CONSTRUCTION/ DEMOLITION PLAN (B) - SHOWING FURNITURE & POWER A-2A REFLECTED CEILING DEMOLITION PLAN (A) A-2B REFLECTED CEILING DEMOLITION PLAN (B) A-3A REFLECTED CEILING PLAN (A) A-3B REFLECTED CEILING PLAN (B) A-4A FINISH PLAN (A) A-4B FINISH PLAN (B) A-5 INTERIOR ELEVATIONS A-6 INTERIOR ELEVATIONS A-7 CONFERENCE ROOM PLAN, SECTION, AND ELEVATION DETAILS CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 7. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS. 8. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN CONFORMANCE WITH CODES AND ORDINANCES. CHANGE OF USE NONE. BASIC REQUIREMENTS 5:23-6.17 (A) TWO EXITS SHALL BE REQUIRED FOR STORIES WITH LESS THAN 500 OCCUPANTS. (B) A MINIMUM OF TWO EGRESS DOORWAYS SHALL BE REQUIRED FOR ROOMS AND SPACES WITH AN OCCUPANT LOAD GREATER THAN 50. ALL EGRESS DOORS SERVING AN OCCUPANT LOAD GREATER THAN 50 SHALL SWING IN THE DIRECTION OF TRAVEL. (C) THE CAPACITY OF THE MEANS OF EGRESS IN EACH WORK AREA SHALL BE DETERMINED IN ACCORDANCE WITH NJAC 5:23-6.11(B). (D) 2. DEAD END CORRIDORS MAY BE UP TO 70 FEET IN LENGTH IN A BUILDING WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED. (E) MEANS OF EGRESS LIGHTING: ARTIFICIAL LIGHTING WITH AN INTENSITY OF NOT LESS THAN ONE FOOT CANDLE AT FLOOR LEVEL SHALL BE REQUIRED DURING ALL TIMES THAT THE CONDITIONS OF OCCUPANCY OF THE BUILDING REQUIRE THAT THE EXITS BE AVAILABLE. (F) ILLUMINATED EXIT SIGNS SHALL BE PROVIDED FOR ALL REQUIRED MEANS OF EGRESS IN ALL BUILDINGS, ROOMS OR SPACES REQUIRED TO HAVE MORE THAN ONE EXIT. (J) STRUCTURAL ELEMENTS: STRUCTURAL ELEMENTS WHICH ARE UNCOVERED DURING THE COURSE OF THE REHABILITATION AND WHICH ARE FOUND TO BE UNSOUND OR OTHERWISE STRUCTURALLY DEFICIENT, SHALL BE REINFORCED, SUPPORTED OR REPLACED IN ACCORDANCE WITH THE APPLICABLE STRUCTURAL DESIGN CRITERIA OF THE BUILDING SUBCODE. WHERE STRUCTURAL ELEMENTS ARE SOUND, THERE IS NO EXCESSIVE DEFLECTION, AND FIXED LOADS ARE NOT CHANGING IN A WAY THAT WILL INCREASE THE STRESSES ON EXISTING STRUCTURES BEYOND THAT WHICH IS PERMITTED BY N.J.A.C. 5:23-6.7(C), EXISTING STRUCTURAL ELEMENTS SHALL BE PERMITTED TO REMAIN. (M) INTERIOR FINISHES SHALL COMPLY WITH N.J.A.C. 5:23-6.11(C). (O) FIREBLOCKING AND DRAFTSTOPPING: WHEN THE WORK BEING PERFORMED CREATES OR EXPOSES THE FRAMING OF ANY WALL, FLOOR, CEILING, OR ROOF, THE FRAMING SHALL COMPLY WITH SECTION 717 OF THE BUILDING SUBCODE. ALTERATION NOTES: ALL WORK SHALL COMPLY WITH NJUCC 5:23-6.6 ALTERATIONS. IN PARTICULAR, THE WORK SHALL MEET THE FOLLOWING: S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\CVR.dwg, 11/20/2012 5:04:05 PM 6.6 (C) 2. EXISTING FIRE ALARM, AUTOMATIC SPRINKLER, STANDPIPE, SMOKE CONTROL AND EMERGENCY POWER SYSTEMS SHALL NOT BE REMOVED WITHOUT REPLACEMENT AND SHALL BE MAINTAINED IN OPERATING CONDITION. 6.6 (C) 3. NO WORK SHALL BE UNDERTAKEN THAT DIMINISHES ACCESSIBILITY BELOW THAT WHICH IS REQUIRED BY THE BARRIER FREE SUBCODE OF THE UNIFORM CONSTRUCTION CODE, N.J.A.C. 5:23-7. 6.6 (C) 4. CONSTRUCTION MATERIALS USED AS PART OF AN ALTERATION PROJECT SHALL BE CONSISTENT WITH THE EXISTING CONSTRUCTION TYPE OR THE ALLOWABLE CONSTRUCTION TYPE, WHICHEVER IS LESS RESTRICTIVE. 6.6 (E) 1. WHEN ANY WATER CLOSET IS REPLACED, THE REPLACEMENT WATER CLOSET SHALL REQUIRE NOT MORE THAN 1.6 GALLONS OF WATER PER FLUSH AS REQUIRED BY THE PLUMBING SUBCODE. 6.6 (E) 2. IN BUILDINGS REQUIRED BY THE BARRIER FREE SUBCODE TO BE ACCESSIBLE, WHEN BATHROOMS OR TOILET ROOMS ARE ALTERED, THE FOLLOWING REQUIREMENTS PROVIDING ACCESSIBILITY SHALL APPLY UNLESS THE REQUIREMENTS OF THE BARRIER FREE SUBCODE HAVE BEEN MET: 6.6 (E) 2.ii. WHEN BATHROOM FIXTURES OR HARDWARE ARE REPLACED, THE REPLACEMENT FIXTURES OR HARDWARE SHALL COMPLY WITH ICC/ANSI A117.1-2003, SECTIONS 603 THROUGH 608. 6.6 (E) 2.iii. WHEN SPACE IS RECONFIGURED, THE ALTERED SPACE SHALL COMPLY WITH THE BARRIER FREE SUBCODE, N.J.A.C. 5:23-7. 6.6 (E) 3.i. WHEN NEW DOOR OPENINGS ARE CREATED OR DOOR ASSEMBLIES ARE REPLACED AND THE REQUIRED DOOR WIDTH CAN BE ACHIEVED WITHIN THE EXISTING OPENING, THE NEW DOOR SHALL COMPLY WITH ICC/ ANSI A117.1-2003, SECTION 404. 6.6 (E) 6. REPLACEMENT GLASS SHALL COMPLY WITH THE "SAFETY GLAZING" REQUIREMENTS OF THE BUILDING SUBCODE AND SHALL BE INSTALLED IN THE "SPECIFIC HAZARDOUS LOCATIONS" AS SPECIFIED BY SECTION 2406.3 OF THE BUILDING SUBCODE. 6.6 (E) 7. WHERE A FIREPROOFING MATERIAL IS REMOVED THAT IS INTEGRAL TO THE RATING OF AN EXISTING FIRE-RATED ASSEMBLY, THE MATERIAL SHALL BE REPLACED SO THAT THE RATING IS PRESERVED. 6.6 (E) 14. WHEN THE WORK BEING PERFORMED CREATES OR EXPOSES WOOD FRAMING OF ANY WALL, FLOOR, CEILING, OR ROOF, FIRE-BLOCKING SHALL BE PROVIDED AS REQUIRED BY SECTION 717.2 OF THE BUILDING SUBCODE. 6.6 (E) 15. WHEN THE WORK BEING PERFORMED CREATES OR EXPOSES THE ENTIRE FRAMING OF ANY WALL, FLOOR, CEILING, OR ROOF ASSEMBLY THAT IS PART OF THE BUILDING THERMAL ENVELOPE (ENCLOSES CONDITIONED SPACE) AND THERE IS NO INSULATION IN THE CAVITIES, INSULATION MEETING A MINIMUM R-VALUE SHALL BE INSTALLED THAT FILLS THE CAVITIES OF THE FRAMED ASSEMBLY. 9. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE. 10. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION. COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY. 11. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT, CONSULT THE ARCHITECT. MAIN ENTRANCE 12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS OF FINISHES. 13. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR MOUNTED TO WALLS OR CEILINGS. 14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION. 15. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS OTHERWISE NOTED. N FIRE DEPARTMENT NOTES: 1. PROVIDE FIRE EXTINGUISHER CABINETS OR MOUNTING BRACKETS WHERE SHOWN ON DRAWINGS WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL LOCATIONS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. PORTABLE EXTINGUISHERS ARE TO BE PROVIDED BY TENANT OR LANDLORD AND HAVE A RATING NOT LESS THAN 2A. 2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. 3. PROVIDE EMERGENCY LIGHTING PER ELECTRICAL DRAWINGS OF ONE FOOT-CANDLE AT FLOOR LEVEL. COMPLY WITH BUILDING CODES. 4. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES. 5. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING AND SHALL BE SELF-CLOSING. 6. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE PERSONS AND IN ANY HAZARDOUS AREA. 7. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY 150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME SPREAD 26-75, SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III, FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER LOCATION. 8. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE NON-COMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER. 9. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS OR CEILINGS. 10. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. 11. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. 12. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 13. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK. 14. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. ALL STROBES TO FLASH SIMULTANEOUSLY AS REQUIRED BY CODE. 15. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION. 16. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL, PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION. SELECTIVE DEMOLITION NOTES: 1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION. 2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND WORKERS. 3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH ADJACENT SURFACES. 4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED AREAS AT NO COST TO THE OWNER. 5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS. 6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND FIXTURES AS REQUIRED FOR NEW WORK. 7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK. 8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES, UNLESS OTHERWISE NOTED. 9. REMOVE EXISTING FLOOR FINISHES WHERE INDICATED AND PREPARE SUBFLOOR AS REQUIRED FOR NEW FLOOR FINISHES. REFLECTED CEILING NOTES: 1. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: A. PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM NO. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. B. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER TWO WALLS. C. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING CODES. IN ADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL. D. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE ABOVE. 2. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED. 3. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH ADJACENT FINISH, UNLESS OTHERWISE NOTED. POWER & COMMUNICATIONS NOTES: 1. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY SYSTEMS. 2. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION. 3. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER EQUIPMENT. NO SYMBOLS: 6. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS REQUIRED BY ACCESSIBILITY GUIDELINES, UNLESS OTHERWISE NOTED. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +3'-2" ABOVE FINISHED FLOOR. A WALL TYPE SECTION MARK DOOR TAG DETAIL TAG SECTION NO. DWG. NO. 1 A-2 DOOR NO. 101 DETAIL NO. DWG. NO. 1 A-2 CEILING PAINT COLOR P-1 ELEVATION SECTION NO. DWG. NO. PARTITIONS EXISTING (UNSHADED) NEW (SHADED) 8. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL BACK-TO-BACK. 9. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED. 1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, AND FREE OF IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 2. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW FINISHES. HVAC NOTES: 1. THE EXISTING HVAC SHALL REMAIN AND BE RE-WORKED IF NECESSARY AS A RESULT OF THIS WORK. THIS INCLUDES RELOCATING DIFFUSERS, RETURN GRILLES, ETC. SPRINKLER NOTES: 100 KEY NOTE TAG X EQUIPMENT AND MILLWORK TAG WALL FINISH BASE FINISH X X FINISH TAG WALL FINISH WALL FINISH BASE FINISH X X X FLOOR FINISH ABBREVIATIONS: SPRINKLER HEAD GYPSUM WALL BOARD GYPSUM HANDICAP HOLLOW METAL MAXIMUM MINIMUM MASONRY OPENING METAL NOT APPLICABLE NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OUTSIDE DIAMETER REQUIRED SPECIFICATIONS STEEL STRUCTURAL TOP OF TYPICAL UNLESS OTHERWISE NOTED VINYL COMPOSITION TILE VERIFY IN FIELD XXX FINISH TAG DOOR PAINT GWB. GYP. HC HM MAX. MIN. M.O. MTL N/A N.I.C. NO. NTS O.C. O.D. REQ. SPECS. STL STRUCT. T.O. TYP. U.O.N. VCT V.I.F. 1 A-2 ROOM NUMBER 1. THE EXISTING SPRINKLER SYSTEM SHALL REMAIN AND BE RE-WORKED IF NECESSARY AS A RESULT OF THIS WORK. THIS INCLUDES RELOCATING SPRINKLER HEADS. A.F.F. ABOVE FINISHED FLOOR ALIGN ALIGNMENT ALUM. ALUMINUM BD. BOARD BLDG BUILDING B.O. BOTTOM OF C.J. CONTROL JOINT CLG CEILING C.M.U. CONC. MASONRY UNIT COL. COLUMN CONC. CONCRETE CONT. CONTINUOUS DEMO. DEMOLISH DET. DETAIL DIA. DIAMETER DN. DOWN DWG. DRAWING EL. / ELEV. ELEVATION EQ. EQUAL F.E. FIRE EXTINGUISHER F.F. FINISHED FLOOR FLR. FLOOR FURN. FURNITURE GALV. GALVANIZED 11.19.2012 LEVEL LINE, START POINT OR DATUM 7. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED. FINISH NOTES: FOR BID & PERMIT DATE NTS 4. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE. 5. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH ACCESSIBILITY REQUIREMENTS. 01 ISSUE XXX DOOR FINISH FRAME FINISH SUPPLY DIFFUSER ANEMOSTAT PLATEAU TYPE U.O.N. EXHAUST FIRE STROBE FS FIRE SPEAKER STROBE FSS ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 MOTION SENSOR EXISTING DOOR NEW DOOR PROJECT DESCRIPTION, GENERAL NOTES, SYMBOLS & KEY SITE PLAN DUPLEX OUTLET CVR 1/4" - 1/2" CHANGES IN LEVEL (A) FRONT APPROACH, PULL SIDE UNOBSTRUCTED HIGH SIDE REACH CLEAR WIDTH OF DOORWAY 2 MOUNTING HEIGHTS 32" min DOOR FRAME 1 COAT HOOK 60 " MIN ADA COAT HOOK 12" THERMOSTAT, INTERCOM OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER 18" MIN LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. CLUSTER, (SEE PLAN FOR QUANTITY OF EACH CLUSTER) 80" DOORWAYS WITHOUT DOORS CLEAR FLOOR SPACE CLEAR WIDTH OF AN ACCESSIBLE ROUTE 30" MIN NOTE: X = 12" MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED. 36" MIN A.F.F. X 38" X 48" 10" MAX NOTE: X = 10" MAX IF Y = 48" MAX. X = >10" - 24" MAX IF Y = 46" MAX 48" MIN 48" MIN 66" CLEAR FLOOR AREA 46" SCALE: NTS 34" MAX 1 THRESHOLDS Y 1/4" MAX FIRE ALARM DEVICE 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com DOOR LEVER, PULL POWER AND TELEPHONE RECEPTACLE DOOR OR OPENING > 24" 36" MIN s t u d i o 1 2 0 0, LLC FINISH FLOOR EDGE OF DOOR OR SIDELIGHT PANEL TYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC. CERITFICATE OF AUTHORIZATION # AC-710 10" MAX 32" MIN (B) FRONT APPROACH, PUSH SIDE Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 COAT HOOK 17" - 25" 24" MAX FIRE ALARM DEVICE (C&D) HINGE APPROACH, PULL SIDE DOOR FRAME 12" 2 DOORS IN A SERIES NOTE: X = 36" MIN. IF Y = 60" MIN. X = 42" MIN. IF Y = 54" MIN. KNEE & TOE CLEARANCE THERMOSTAT, INTERCOM OR 2ND ROW OF RECEPTACLES CENTER TO CLUSTER MIRROR LIGHT SWITCH, DIMMERS, EGRESS BUTTON, INTERCOM BUTTON, CARD READER, ETC. CLUSTER, (SEE PLAN FOR QUANTITY OF EACH CLUSTER) 80" 38" 46" DOOR LEVER, PULL POWER AND TELEPHONE RECEPTACLE 24" MAX 3'-4" MAX DOOR OR OPENING 60" MIN 2'-10" MAX 2'-5" MIN 2'-3" MIN 9" MIN X A.F.F. 66" LINE OF REQUIRED CLEARANCE. Y 48" MIN INSULATE HOT WATER PIPES AND DRAIN TO PREVENT CONTACT. (E) HINGE APPROACH, PUSH SIDE 32" MIN MAX KNEE CLEARANCE 8" MIN 6" MAX TOE CLEARANCE NOTE: X = 12" MIN. IF BOTH CLOSER AND LATCH ARE PROVIDED. Y = 42" MIN. Y = 48" MIN IF BOTH CLOSER AND LATCH ARE PROVIDED. Y 36" MIN 1'-5" MIN DEPTH X FINISH FLOOR TYPICAL LOCATION FOR TWO ROWS OF LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC. EDGE OF DOOR OR SIDELIGHT PANEL 60" MIN 22" MIN TYPICAL WALL PANEL JOINT 2 SINK OR VANITY SCALE: 1/2" = 1'-0" UNOBSTRUCTED FORWARD REACH CLEAR WIDTH AT TURN NOTE: X = 36" MIN IF Y = 60" MIN. X = 42" MIN IF Y = 48" MIN. EQ. EQ. EQ. POWER AND TELEPHONE RECEPTACLE & CLUSTER HORIZONTALLY MOUNTED, CENTERED BETWEEN PANEL JOINT EQ. Y 48" MAX 6" 2 DOORS IN A SERIES 15" 15" MIN (F) LATCH APPROACH, PULL SIDE FINISH FLOOR Y DOOR WIDTH NOTE: Y = 48" MIN. Y = 54" MIN IF CLOSER IS PROVIDED. TYPICAL LOCATION FOR POWER AND TELEPHONE OUTLETS AT WALL PANEL OR COLUMN NO 01 ISSUE FOR BID & PERMIT DATE 11.19.2012 24" MIN UNOBSTRUCTED HIGH FORWARD REACH 48" MIN NOTE: X = >20 - 25" IF Y = 44" MAX. X = 20" MAX IF Y = 48" MAX (G) LATCH APPROACH, PUSH SIDE 6" SO HANDLE OF EXTINGUISHER IS 48" AFF ELEC DATA 15" Y GRAB BAR AND ACCESSORIES DOOR WIDTH Y NOTE: Y = 42" MIN. Y = 48" MIN IF CLOSER IS PROVIDED. BACKBOX SIZES TO BE CONFIRMED & COORDINATED WITH DATA/TEL VENDOR. 48" X X < 48 FINISH FLOOR 24" MIN X TYPICAL LOCATION FOR FIRE EXTINGUISHER/FIRE EXTINGUISHER CABINET. TYPICAL LOCATION FOR COMBINED OUTLETS AT VISIBLE AREAS 3 REACH RANGES SCALE: 1/2" = 1'-0" 36" MIN LIMITS OF PROTRUDING OBJECTS 4" max 18" MIN 12" MIN EQ. 12" 16"-18" EQ. WALL HUNG TELEPHONE 24" MIN 4" MAX. 48" 48" EDGE OF DOOR OR SIDELIGHT PANEL DOOR OR OPENING 15" 15" 60" MIN 60" MIN. 31" MIN. TYPICAL LOCATION FOR WALL HUNG TELEPHONE AT WALL OR COLUMN DOOR WIDTH 28" MIN WALL OUTLET 48" MIN 60" MIN. 17"-19" 15" MIN 33"-36" 39"-41" WHEELCHAIR ACCESSIBLE STALL 80" MIN ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 60" MIN UNOBSTRUCTED SIDE REACH 4" MAX. 54" MIN 42" MIN EQ. 12" 39"-41" AMBULATORY ACCESSIBLE STALL 12" MAX EQ. RECESSED PULLSTATION SCALE: 1/2" = 1'-0" 80" 36" MIN. CLEARANCES & GENERAL MOUNTING HEIGHTS SCALE: 1/2" = 1'-0" 39"-41" 48" CLEARANCES 33"-36" 15" MIN 4 7"-9" 17"-19" CL 10" MAX CLEARANCES 24" MIN.* 48" MAX 18" MIN 60" MIN. 15" MIN S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-0_Clearances.dwg, 11/20/2012 5:04:11 PM X FIRE EXTINGUISHER CABINET DOOR OR OPENING * AT AMBULATORY STALLS ONLY EDGE OF DOOR OR SIDELIGHT PANEL TYPICAL LOCATION FOR SINGLE WALL MOUNTED FIRE ALARM DEVICE /PULL STATION AT WALL OR COLUMN 5 CLEARANCES SCALE: 1/2" = 1'-0" 6 CLEARANCES SCALE: 1/2" = 1'-0" 7 GENERAL MOUNTING HEIGHTS SCALE: 1/2" = 1'-0" 8 A-0 GENERAL NOTES: B307 B308 B309 B310 B311 B312 B313 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE ELECTRICAL SYMBOLS SYM. TYPE 3 WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED. NUMBER REPRESENTS AMOUNT OF RECEPTICLES AT SYSTEM FURNITURE DEDICATED WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK OF ALL CONSULTANTS AND SUBCONTRACTORS, WHETHER HIRED BY THE OWNER OR BY CONTRACTOR. 2. CONTRACTOR IS RESPONSIBLE FOR ALL WORK IDENTIFIED ON ALL DRAWINGS UNLESS OTHERWISE NOTED. 3. SHADED AREA ON PLAN INDICATES AREAS OUTSIDE SCOPE OF WORK (NIC). 4. REFER TO PLAN FOR ALL ELEVATION TAGS. 5. ALL NEW INTERIOR FRAMING SHALL MATCH EXISTING 2X CONSTRUCTION OF ADJACENT WALLS U.O.N. AND ARE SHOWN SHADED ON PLAN. 6. DIMENSIONS SHOWN ARE MEASURED FROM FACE OF FINISH WALL. WALL MTD. QUAD RECEPTACLE, "R" DENOTES RELOCATED 1 GFCI EQ-4 EQ-4 WALL MTD. GFCI DUPLEX RECEPTACLE WALL MTD. "POWER INFEED" FOR VOICE/ DATA CONNECTIONS TO MODULAR FURNITURE. COORDINATE W/ FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW. "E" DENOTES EXISTING. B306 FLOOR MTD. "POWER INFEED" FOR VOICE/ DATA AND ELECTRICAL CONNECTIONS TO MODULAR FURNITURE. CUT AND PATCH SLAB ACCORDINGLY FOR FEED AND CONDUIT. RELOCATE EXISTING POWER IN-FEED AS INDICATED ON PLAN FOR NEW FURNITURE LAYOUT. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW, "E" DENOTES EXISTING. 4 3 4 3 4 3 ADMIN. 4 3 OFFICE 7. CONTRACTOR SHALL PROVIDE FIRE RETARDANT BLOCKING IN WALLS AS REQUIRED FOR MILLWORK, LCD TV'S, ETC. 8. THE ENTIRE AREA IN SCOPE SHALL BE THOROUGHLY CLEANED, INCLUDING WAXING & POLISHING AT THE COMPLETION OF CONSTRUCTION. 3 4 3 4 3 4 3 ADMIN. WALL MTD. VOICE RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME RUNS 2 EQ-1 EQ-10 OFFICE 4 3 13 4 3 B305 4 3 4 3 12 13 4 WALL MTD. COMBINATION VOICE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT5 HOME RUNS 1 WALL MTD. CABLE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME RUNS B304 OFFICE EQ-24 EQ-27 2 EQ-26 EQ-28 A-5 EQ-29 6 4 3 10. REFER TO REFLECTED CEILING PLAN ON A-3A & A-3B FOR NEW LIGHTING SPECIFICATION. WALL MTD. CABLE T.V. CONNECTION 11. SEE EQUIPMENT SCHEDULE & ELECTRICAL SYMBOLS THIS SHEET FOR MORE INFORMATION. RECESSED FLOOR BOX , FSR 500P-S-C - 3" DEEP, CONFIRM WITH TENANT COMPONENTS WITH 12. ALL NEW OUTLETS SHALL BE MTD. @ 18" A.F.F. U.O.N. CR CARD READER EB EGRESS OVERRIDE BUTTON IR INFRARED OVERHEAD RELEASE CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 14. DIMENSIONS AT FURNITURE LOCATIONS TO BE COORDINATED AND CONFIRMED WITH FURNITURE VENDOR, FURNITURE VENDOR WILL BE MARKING OUT LOCATIONS OF FLOOR BOXES AND PANELS EXISTING DATA AND DUPLEX TO REMAIN E 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com 13. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EXISTING CARPET, TILE, AND BASE IN AREAS OF WORK. CONTRACTOR SHALL PREPARE ALL SURFACES AS REQUIRED TO RECEIVE NEW FINISHES. B303 OFFICE REFER TO FINISH PLAN ON A-4A & A-4B FOR ALL NEW FINISHES. 9. s t u d i o 1 2 0 0, LLC 15. EXISTING POWER AND DATA AT OFFICES TO REMAIN U.O.N. 4 3 B302 OFFICE PHASE III 16. GC SHALL REMOVE AND DISCARD ALL EXISTING 1X2 ACCENT WOOD TRIM BAND CURRENTLY INSTALLED BETWEEN DOOR AT VARIOUS LOCATIONS THROUGHOUT OPEN OFFICE AREAS. 4 3 EQUIPMENT SCHEDULE B301 SYM. DESCRIPTION MANUFACTURER MODEL NUMBER NOTES OFFICE 4 3 EQ-1 B300 EQ-2 MULTI FUNCTION PRINTER/COPIER BY TENANT PAPER SHREDDER BIN CANON - 5055 - A307 A306 A305 A304 A303 A302 A301 A300 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONF. RM. 13 INSTALLED BY CONTRACTOR. SPECIAL PLUG - NEMA 5-20R 17. PROVIDE 3'-0" WIDE TRIMMED OPENING AND SIDE LITE TO MATCH EXISTING (ALUMINUM EXTRUDED GLASS CHANNEL WITH REMOVABLE STOP) TO ALL PERIMETER OFFICES U.O.N. SEE DETAIL # 1 ON A-6. TO BE RELOCATED 18. CONTRACTOR TO MODIFY OR RELOCATE EXISTING POWER AND DATA INFEED AS REQUIRED BY NEW FURNITURE. 19. CONTRACTOR TO RELOCATE ALL SWITCHES AS REQUIRED DUE TO INSTALLATION OF NEW SIDELIGHTS. (FLOOR STANDING) OFFICE A308 EXISTING NOTES EQ-3 LASER JET DESKTOP PRINTER HP 4015 TO BE RELOCATED, AS SHOWN EQ-4 LASER JET DESKTOP PRINTER HP 4250 TO BE RELOCATED, AS SHOWN EQ-5 LASER PRINTER/COPIER BY TENANT CANON 2050 EQ-30 3 5 16 A-6 1 2 A-6 A-6 4 EQ-6 POWER SHRED FELLOWS C-120 4 EQ-7 FAX PITNEY BOWES 1630 1 OFFICE 4 3 4 3 4 3 4 3 13'-0" A327 A328 OFFICE OFFICE 4 4 3 23'-2" A310 7 A343 HP TO BE RELOCATED, AS SHOWN H TO BE RELOCATED, AS SHOWN NJ2AVXTECPRT11 EQ-9 FAX TOSHIBA - TO BE RELOCATED, AS SHOWN EQ-10 MULTI FUNCTION PRINTER/COPIER BY TENANT CANON 5185 PLUG - NEMA 5-20R TO BE PROVIDED BY CONTRACTOR EQ-11 ENERGY STAR MINI FRIDGE - - REMOVED FROM THE PLAN EQ-12 LASER JET DESKTOP PRINTER HP 9050 TO BE RELOCATED, AS SHOWN EQ-13 LASER PRINTER/COPIER BY TENANT IKON CANON CLASS -810 TO BE RELOCATED, AS SHOWN EQ-27 4 3 1 EQ-29 2 A-5 DESKTOP FAX BROTHER INTELLIFAX OFFICE A325 4 14 EQ-15 NOT USED - - EQ-16 LASER JET DESKTOP PRINTER HP P4015N EQ-17 LASER JET DESKTOP PRINTER HP P4650N EQ-18 MULTI FUNCTION PRINTER/COPIER BY TENANT TOSHIBA STUDIO 170F EQ-19 LASER FAX CANON CLASS-730I EQ-20 MULTI FUNCTION PRINTER/COPIER BY TENANT CANON CLASS-730I EQ-21 MULTI FUNCTION PRINTER/COPIER BY TENANT GENICOM 5000 EQ-22 FAX LEXMARK AVFLTLAZERO6 EQ-23 LOCKABLE CABINET - - - OFFICE CONF. RM. CONF. RM. H TO BE RELOCATED, AS SHOWN 3 OFFICE 4 3 4 3 4 3 4 3 ADMIN. 3 REMOVE EXISTING POWER AND DATA INFEED AT FLOOR OR WALL, SAFE OFF AND PATCH AS REQUIRED 4 REMOVE DOOR, FRAME, & HARDWARE. INFILL WALL SECTION TO MATCH EXISTING ADJACENT WALL AS REQUIRED. PROVIDE NEW SIDELIGHT IN INDICATED LOCATIONS. 5 CORE FLOOR FOR NEW TABLE TOP POWER & DATA AT CONFERENCE TABLE. PROVIDE SEPARATE CORES, ONE 3 4" FOR DUPLEX OUTLET & ONE 2" FOR AV &DATA BELOW THE TABLE. AN ADDITIONAL 2" CORE IN AN ADJACENT WALL TO RUN CABLE FROM TABLE TOP TO CEILING MOUNTED PROJECTOR. COORDINATE LOCATION WITH EXISTING FURNITURE. COORDINATE WITH FURNITURE VENDOR FOR THE INSTALLATION OF NEW CABLE CUBBIE AT THE EXISTING CONFERENCE TABLES. CABLE CUBBIE TO BE PROVIDED BY OWNER. 6 DEMOLISH REMOVE AND DISCARD EXISTING PANTRY MILLWORK. RELOCATE EXISTING PLUMBING TO CONFORM TO NEW PANTRY LAYOUT 7 DEMOLISH REMOVE AND DISCARD EXISTING PARTITIONS REMOVE ALL POWER TO NEAREST JUNCTION BOX, COORDINATE REMOVAL OF DATA WITH TENANT. 8 CONTRACTOR TO COORDINATE POWER TO TABLE TOP PRINTER(S) AND FAX(ES) WITH FURNITURE VENDOR, PROVIDE ADDITIONAL CIRCUITS IF NECESSARY. 9 PROVIDE FILM BAND UP TO 5'-6" A.F.F. SEE ELEVATION. TO BE RELOCATED, AS SHOWN X 1'-9" H TO BE RELOCATED, AS SHOWN X 1'-6" H TO BE RELOCATED, AS SHOWN X 1'-6" H TO BE RELOCATED, AS SHOWN 11 DEMOLISH REMOVE AND DISCARD ELECTRIC WATER HEATHER IN CEILING. TO BE RELOCATED, CONTRACTOR TO VERIFY PLUG TYPE 12 CONTRACTOR TO COORDINATE THE POWER AND DATA CONNECTIONS FOR PRINTER. USE EXISTING POWER AND DATA AT COLUMN, DO NOT CONNECT EQUIPMENT TO WORKSTATION. TO BE RELOCATED, AS SHOWN 13 NO 01 ISSUE FOR BID & PERMIT DATE 11.19.2012 1 A341 A323 A314 4 3 4 3 4 3 OFFICE EQ-22 10 EXISTING EXECUTIVE PANTRY TO BE GUTTED, DEMOLISH REMOVE AND DISCARD EXISTING MILLWORK; SAFE OFF AND CAP EXISTING ELECTRICAL AND PLUMBING. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ELECTRICAL WITH FURNITURE VENDOR AND TENANT. 1 4 3 4 3 4 3 4 3 5 CONF. RM. 4 3 3 H A324 8 CONTRACTOR SHALL VERIFY MAX. SIDE LITE WIDTH @ THIS LOCATION. - N A330 OFFICE 2 OFFICE A329 OFFICE NO SIDE LITE AT THIS LOCATION. 14 A312 A313 1 TO BE RELOCATED, AS SHOWN 2820 5 A342 EQ-21 8'-2" 4 3 EQ-11 EQ-14 OFFICE EQ-30 8 A326 EQ-2 EQ-28 4 9 4 CONF. ROOM OFFICE A-7 4 OFFICE A345 4 A311 LASER JET DESKTOP PRINTER X 1'-4" H 1 5 OFFICE X 2'-6" H TO BE RELOCATED, AS SHOWN 10 11 4 3 A309 X 3'-5" H 1 X 1'-6" H SEE EQUIPMENT SCHEDULE FOR PLUG REQUIREMENT. 3'-0" 9 3/8" ADMIN. 4 3 ADMIN. 4 3 4 3 17 4 3 S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-1A_Construction.dwg, 11/20/2012 5:04:15 PM 4 3 4 3 EQ-8 ADMIN. TO BE RELOCATED, AS SHOWN SHEET NOTES: TYP. ADMIN. X 1'-4" H A340 OFFICE 3'-0" TO BE RELOCATED, AS SHOWN 4 EQ-7 UNDER COUNTER REFRIGERATOR SUMMIT APPLIANCE FF6ADA WHITE SUPPLIED & INSTALLED BY CONTRACTOR EQ-25 FULL SIZE REFRIGERATOR GE GTH21KBXWW NEW PROVIDED BY TENANT AND INSTALLED BY CONTRACTOR 17 PROTECT EXISTING WALL COVERING TO REMAIN IN THIS AREA. SEE FINISH PLAN. EQ-26 2.0 CU. FT. COUNTERTOP MICROWAVE OVEN G.E. PROFILE PEB2060DMWW WHITE SUPPLIED BY TENANT INSTALLED BY CONTRACTOR 18 NEW DOOR, NEW HARDWARE OFFICE FUNCTION, MATCH BUILDING STANDARD FINISH, BRUSHED CHROME. EQ-27 ADA STAINLESS STEEL BOWL SINK ELUHAD2115 STAINLESS STEEL UNDERMOUNT SUPPLIED & INSTALLED BY CONTRACTOR STAINLESS STEEL MATCH EXISTING SUPPLIED & INSTALLED BY CONTRACTOR SUPPLIED BY TENANT, CONTRACTOR TO PROVIDE WATER CONNECTION W/ SHUT OFF PLUG - NEMA 5-15R PROVIDED BY CONTRACTOR 19 1 OFFICE 4 16 PHASE II 1 1 4 5 EQ-28 A316 A317 A318 A319 A320 A321 A322 OFFICE OFFICE OFFICE OFFICE CONF. RM. OFFICE OFFICE EQ-29 EQ-30 CONSTRUCTION/ DEMOLITION PLAN (A) - SHOWING FURNITURE & POWER SCALE: 1/8" = 1'-0" 1 15 NEW WALL TALKER. REFER TO ELEVATION 6/A-6 FOR TYPICAL ELEVATION. EQ-24 1 A315 14 PROVIDE POWER FOR WINDOW TREATMENT, SEE FINISH PLAN FOR MORE INFORMATION. ADA FAUCET - WATER DISPENSER - - PROVIDE 1/4" WATER LINE PRINTER CANON 3245 - 16 REMOVE EXISTING WALL COVERING AND PREP FOR NEW FINISH. 19 EXISTING WALL COVERING, CARPET AND BASE TO REMAIN, G.C. TO PROTECT AS REQUIRED. ALTERNATES: A. GENERAL CONTRACTOR TO PROVIDE DEDUCT UNIT PRICE FOR SIDE LIGHTS AT OFFICE LOCATIONS. ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 CONSTRUCTION/ DEMOLITION PLAN (A) - SHOWING FURNITURE & POWER A-1A B314 B315 B316 B317 OFFICE OFFICE OFFICE OFFICE OFFICE E E E SYM. SYM. TYPE 3 WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED. NUMBER REPRESENTS AMOUNT OF RECEPTICLES AT SYSTEM FURNITURE DESCRIPTION MANUFACTURER MODEL NUMBER EQ-1 MULTI FUNCTION PRINTER/COPIER BY TENANT CANON 5055 EQ-2 PAPER SHREDDER BIN - - NOTES EXISTING NOTES E B318a WALL MTD. QUAD RECEPTACLE, "R" DENOTES RELOCATED 1. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WORK OF ALL CONSULTANTS AND SUBCONTRACTORS, WHETHER HIRED BY THE OWNER OR BY CONTRACTOR. 2. CONTRACTOR IS RESPONSIBLE FOR ALL WORK IDENTIFIED ON ALL DRAWINGS UNLESS OTHERWISE NOTED. 3. SHADED AREA ON PLAN INDICATES AREAS OUTSIDE SCOPE OF WORK (NIC). 4. REFER TO PLAN FOR ALL ELEVATION TAGS. 5. ALL NEW INTERIOR FRAMING SHALL MATCH EXISTING 2X CONSTRUCTION OF ADJACENT WALLS U.O.N. AND ARE SHOWN SHADED ON PLAN. INSTALLED BY CONTRACTOR. SPECIAL PLUG - NEMA 5-20R DEDICATED WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED E E GENERAL NOTES: EQUIPMENT SCHEDULE ELECTRICAL SYMBOLS B313 TO BE RELOCATED (FLOOR STANDING) OFFICE R R R 1 3-drawer WALL MTD. GFCI DUPLEX RECEPTACLE GFCI R E B318b ADMIN. ADMIN. 18487224 3-drawer E E N 5-drawer 18487224 WALL MTD. VOICE RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME RUNS 2 E E 18487224 3-drawer E 4 WALL MTD. COMBINATION VOICE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT5 HOME RUNS 1 WALL MTD. CABLE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME RUNS 3 E B319b 24724818 18487224 24724818 E CR CARD READER EB EGRESS OVERRIDE BUTTON E B320 24724818 18487224 5-drawer E TO BE RELOCATED, AS SHOWN EQ-4 LASER JET DESKTOP PRINTER HP 4250 TO BE RELOCATED, AS SHOWN EQ-5 LASER PRINTER/COPIER BY TENANT CANON 2050 X 1'-4" H TO BE RELOCATED, AS SHOWN X 2'-6" H 6. DIMENSIONS SHOWN ARE MEASURED FROM FACE OF FINISH WALL. TO BE RELOCATED, AS SHOWN 7. CONTRACTOR SHALL PROVIDE FIRE RETARDANT BLOCKING IN WALLS AS REQUIRED FOR MILLWORK, LCD TV'S, ETC. X 1'-4" H TO BE RELOCATED, AS SHOWN 8. THE ENTIRE AREA IN SCOPE SHALL BE THOROUGHLY CLEANED, INCLUDING WAXING & POLISHING AT THE COMPLETION OF CONSTRUCTION. H TO BE RELOCATED, AS SHOWN 9. REFER TO FINISH PLAN ON A-4A & A-4B FOR ALL NEW FINISHES. 10. REFER TO REFLECTED CEILING PLAN ON A-3A & A-3B FOR NEW LIGHTING SPECIFICATION. EQ-6 POWER SHRED FELLOWS C-120 EQ-7 FAX PITNEY BOWES 1630 EQ-8 LASER JET DESKTOP PRINTER HP NJ2AVXTECPRT11 EQ-9 FAX TOSHIBA - TO BE RELOCATED, AS SHOWN 5185 PLUG - NEMA 5-20R TO BE PROVIDED BY CONTRACTOR RECESSED FLOOR BOX , FSR 500P-S-C - 3" DEEP, CONFIRM WITH TENANT COMPONENTS WITH N 3 4015 WALL MTD. CABLE T.V. CONNECTION OFFICE E 5'-33 4" HP B319a OFFICE 24724818 18487224 18487224 3-drawer N E 24724818 24724818 ADMIN. 3-drawer FLOOR MTD. "POWER INFEED" FOR VOICE/ DATA AND ELECTRICAL CONNECTIONS TO MODULAR FURNITURE. CUT AND PATCH SLAB ACCORDINGLY FOR FEED AND CONDUIT. RELOCATE EXISTING POWER IN-FEED AS INDICATED ON PLAN FOR NEW FURNITURE LAYOUT. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW, "E" DENOTES EXISTING. OFFICE 3'-71" 2 ADMIN. LASER JET DESKTOP PRINTER E R 3-drawer WALL MTD. "POWER INFEED" FOR VOICE/ DATA CONNECTIONS TO MODULAR FURNITURE. COORDINATE W/ FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW. "E" DENOTES EXISTING. EQ-3 OFFICE INFRARED OVERHEAD RELEASE IR MULTI FUNCTION PRINTER/COPIER BY TENANT CANON EQ-11 ENERGY STAR MINI FRIDGE - - REMOVED FROM THE PLAN EQ-12 LASER JET DESKTOP PRINTER HP 9050 TO BE RELOCATED, AS SHOWN EQ-10 E EXISTING DATA AND DUPLEX TO REMAIN E 3-drawer 3-drawer B321 8 OFFICE EQ-17 EQ-2 EQ-13 2-drawer EQ-14 24724818 R 18487224 IKON CANON DESKTOP FAX BROTHER INTELLIFAX CLASS -810 TO BE RELOCATED, AS SHOWN 2820 TO BE RELOCATED, AS SHOWN E R E 9 LASER PRINTER/COPIER BY TENANT E B322 OFFICE EQ-15 PHASE III E 24724818 5-drawer 18487224 B323 E 5'-10" R C301 C302 C303 C304 C305 C306 C307 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 9 18487224 10 1 A-6 A-6 24724818 E E E 3-drawer R 3-drawer 3-drawer R 3'-101" 2 3'-01" 2 N E 3-drawer ADMIN. EQ-4 4-drawer N N E N E 3-drawer E E E OFFICE EQ-28 EQ-25 EQ-24 3-drawer EQ-1 EQ-26 R EQ-29 CLASS-730I EQ-21 MULTI FUNCTION PRINTER/COPIER BY TENANT GENICOM 5000 R 4'73 4" 5-drawer EQ-22 FAX LEXMARK AVFLTLAZERO6 EQ-23 LOCKABLE CABINET - - TO BE RELOCATED, AS SHOWN X 3'-5" H TO BE RELOCATED, CONTRACTOR TO VERIFY PLUG TYPE SHEET NOTES: EQ-24 UNDER COUNTER REFRIGERATOR SUMMIT APPLIANCE EQ-25 FULL SIZE REFRIGERATOR EQ-26 X 1'-6" H TO BE RELOCATED, AS SHOWN 1 NO SIDE LITE AT THIS LOCATION. 2 CONTRACTOR SHALL VERIFY MAX. SIDE LITE WIDTH @ THIS LOCATION. 3 REMOVE EXISTING POWER AND DATA INFEED AT FLOOR OR WALL, SAFE OFF AND PATCH AS REQUIRED FF6ADA WHITE SUPPLIED & INSTALLED BY CONTRACTOR 4 GE GTH21KBXWW NEW PROVIDED BY TENANT AND INSTALLED BY CONTRACTOR REMOVE DOOR, FRAME, & HARDWARE. INFILL WALL SECTION TO MATCH EXISTING ADJACENT WALL AS REQUIRED. PROVIDE NEW SIDELIGHT IN INDICATED LOCATIONS. 5 2.0 CU. FT. COUNTERTOP MICROWAVE OVEN G.E. PROFILE PEB2060DMWW WHITE SUPPLIED BY TENANT INSTALLED BY CONTRACTOR EQ-27 ADA STAINLESS STEEL BOWL SINK ELUHAD2115 STAINLESS STEEL UNDERMOUNT SUPPLIED & INSTALLED BY CONTRACTOR EQ-28 ADA FAUCET - STAINLESS STEEL MATCH EXISTING SUPPLIED & INSTALLED BY CONTRACTOR CORE FLOOR FOR NEW TABLE TOP POWER & DATA AT CONFERENCE TABLE. PROVIDE SEPARATE CORES, ONE 3 4" FOR DUPLEX OUTLET & ONE 2" FOR AV &DATA BELOW THE TABLE. AN ADDITIONAL 2" CORE IN AN ADJACENT WALL TO RUN CABLE FROM TABLE TOP TO CEILING MOUNTED PROJECTOR. COORDINATE LOCATION WITH EXISTING FURNITURE. COORDINATE WITH FURNITURE VENDOR FOR THE INSTALLATION OF NEW CABLE CUBBIE AT THE EXISTING CONFERENCE TABLES. CABLE CUBBIE TO BE PROVIDED BY OWNER. 6 PROVIDE 1/4" WATER LINE SUPPLIED BY TENANT, CONTRACTOR TO PROVIDE WATER CONNECTION W/ SHUT OFF DEMOLISH REMOVE AND DISCARD EXISTING PANTRY MILLWORK. RELOCATE EXISTING PLUMBING TO CONFORM TO NEW PANTRY LAYOUT 7 - PLUG - NEMA 5-15R PROVIDED BY CONTRACTOR DEMOLISH REMOVE AND DISCARD EXISTING PARTITIONS REMOVE ALL POWER TO NEAREST JUNCTION BOX, COORDINATE REMOVAL OF DATA WITH TENANT. EQ-23 8 CONTRACTOR TO COORDINATE POWER TO TABLE TOP PRINTER(S) AND FAX(ES) WITH FURNITURE VENDOR, PROVIDE ADDITIONAL CIRCUITS IF NECESSARY. 3-drawer ALIGN 9 PROVIDE FILM BAND UP TO 5'-6" A.F.F. SEE ELEVATION. 3-drawer 3-drawer CANON 5-drawer 3-drawer 3-drawer 1" 3'-62 PHASE I 3-drawer 3245 OFFICE 18487224 18487224 24724818 18487224 C314 3'-6" 24724818 24724818 24724818 24724818 18487224 PRINTER OFFICE 5-drawer 3-drawer 1" 3'-64 E - E 18487224 4'-21" 4 - C313 E 4-drawer 3-drawer WATER DISPENSER E E E ISSUE FOR BID & PERMIT DATE 11.19.2012 R 24724818 24724818 24724818 24724818 24724818 18487224 18487224 18487224 18487224 18487224 18487224 11 DEMOLISH REMOVE AND DISCARD ELECTRIC WATER HEATHER IN CEILING. C315 E OFFICE 8 E E 2'-01" 4 EQ-3 PE 18487224 EQ-30 12 18487224 18487224 18487224 E 24724818 24724818 E OFFICE 24724818 24724818 C327b PE 13 E 24724818 24724818 24724818 24724818 24724818 ADMIN. 18487224 18487224 18487224 ADMIN. 18487224 E 18487224 ADMIN. C327a 12 CONTRACTOR TO COORDINATE THE POWER AND DATA CONNECTIONS FOR PRINTER. USE EXISTING POWER AND DATA AT COLUMN, DO NOT CONNECT EQUIPMENT TO WORKSTATION. E 13 E ADMIN. C316 E 15 NEW WALL TALKER. REFER TO ELEVATION 6/A-6 FOR TYPICAL ELEVATION. E 2 3-drawer E E 3-drawer 3-drawer 3-drawer 3-drawer E 3-drawer 16 REMOVE EXISTING WALL COVERING AND PREP FOR NEW FINISH. E 17 PROTECT EXISTING WALL COVERING TO REMAIN IN THIS AREA. SEE FINISH PLAN. 1 R R R R R E E E E E E E E E R 1 R E E E E 19 EXISTING WALL COVERING, CARPET AND BASE TO REMAIN, G.C. TO PROTECT AS REQUIRED. E E ALTERNATES: A. C326 C325 C324 C323 C322 C321 C320 C319 C318 C317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONSTRUCTION/ DEMOLITION PLAN (B) - SHOWING FURNITURE & POWER ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 18 NEW DOOR, NEW HARDWARE OFFICE FUNCTION, MATCH BUILDING STANDARD FINISH, BRUSHED CHROME. E E SEE EQUIPMENT SCHEDULE FOR PLUG REQUIREMENT. 14 PROVIDE POWER FOR WINDOW TREATMENT, SEE FINISH PLAN FOR MORE INFORMATION. OFFICE OFFICE SCALE: 1/8" = 1'-0" NO 10 EXISTING EXECUTIVE PANTRY TO BE GUTTED, DEMOLISH REMOVE AND DISCARD EXISTING MILLWORK; SAFE OFF AND CAP EXISTING ELECTRICAL AND PLUMBING. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ELECTRICAL WITH FURNITURE VENDOR AND TENANT. R OFFICE X 1'-6" H TO BE RELOCATED, AS SHOWN E PHASE II TO BE RELOCATED, AS SHOWN 3'-0" EQ-30 4 E OFFICE C328 X 1'-6" H E E 4 4'-81" 4 E C329 CANON EQ-29 5-drawer R 4 OFFICE MULTI FUNCTION PRINTER/COPIER BY TENANT 19. CONTRACTOR TO RELOCATE ALL SWITCHES AS REQUIRED DUE TO INSTALLATION OF NEW SIDELIGHTS. OFFICE N N N C331 E OFFICE 14 CONF. RM. EQ-20 TO BE RELOCATED, AS SHOWN C312 E 6 4-drawer CONF. RM. CLASS-730I X 1'-9" H E C343 EQ-27 E E EQ-10 E C330 CANON 18. CONTRACTOR TO MODIFY OR RELOCATE EXISTING POWER AND DATA INFEED AS REQUIRED BY NEW FURNITURE. OFFICE 15 C332 LASER FAX 17. PROVIDE 3'-0" WIDE TRIMMED OPENING AND SIDE LITE TO MATCH EXISTING (ALUMINUM EXTRUDED GLASS CHANNEL WITH REMOVABLE STOP) TO ALL PERIMETER OFFICES U.O.N. SEE DETAIL # 1 ON A-6. TO BE RELOCATED, AS SHOWN C311 E EQ-15 A330 EQ-19 R A-5 14 STUDIO 170F 16. GC SHALL REMOVE AND DISCARD ALL EXISTING 1X2 ACCENT WOOD TRIM BAND CURRENTLY INSTALLED BETWEEN DOOR AT VARIOUS LOCATIONS THROUGHOUT OPEN OFFICE AREAS. H OFFICE 3 5 TOSHIBA 15. EXISTING POWER AND DATA AT OFFICES TO REMAIN U.O.N. E N 24724818 18487224 5'-93 4" E EQ-17 EQ-19 9 A-6 MULTI FUNCTION PRINTER/COPIER BY TENANT 14. DIMENSIONS AT FURNITURE LOCATIONS TO BE COORDINATED AND CONFIRMED WITH FURNITURE VENDOR, FURNITURE VENDOR WILL BE MARKING OUT LOCATIONS OF FLOOR BOXES AND PANELS C310 2-drawer 5-drawer E EQ-18 13. CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL EXISTING CARPET, TILE, AND BASE IN AREAS OF WORK. CONTRACTOR SHALL PREPARE ALL SURFACES AS REQUIRED TO RECEIVE NEW FINISHES. 01 ADMIN. 16 8 P4650N 12. ALL NEW OUTLETS SHALL BE MTD. @ 18" A.F.F. U.O.N. E 1 R HP 11. SEE EQUIPMENT SCHEDULE & ELECTRICAL SYMBOLS THIS SHEET FOR MORE INFORMATION. C309 OFFICE 1 3'-43 4" 1" 3'-52 3'-03" 4 E A-7 LASER JET DESKTOP PRINTER Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 1 A-6 16 EQ-17 H TO BE RELOCATED, AS SHOWN CERITFICATE OF AUTHORIZATION # AC-710 C308 N 24724818 3-drawer S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-1B_Construction.dwg, 11/20/2012 5:04:38 PM E 18487224 03 7 E E 24724818 18487224 3-drawer 24724818 PE N 24724818 E R 3-drawer 24724818 18487224 P4015N OFFICE R 3-drawer 24724818 3-drawer 24724818 E E 4-drawer PE E E R 3'-01" 4 N E TYP. R 5'-8" 6'-63 4" 18487224 03 E E 18487224 24724818 E E 18487224 N E 18487224 HP A-6 EQ-10 5'-2" 24724818 LASER JET DESKTOP PRINTER - 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com 5 18487224 4 24724818 12 5-drawer 4 N 18487224 03 EQ-16 - E PE E - CONF. RM. E 18487224 24724818 1" 5'-54 - OFFICE C300 R NOT USED s t u d i o 1 2 0 0, LLC 1 CONSTRUCTION/ DEMOLITION PLAN (B) - SHOWING FURNITURE & POWER GENERAL CONTRACTOR TO PROVIDE DEDUCT UNIT PRICE FOR SIDE LIGHTS AT OFFICE LOCATIONS. A-1B B307 B308 B309 B310 B311 B312 B313 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE GENERAL NOTES: SYMBOLS SYM. TYPE EXISTING 2X4 CEILING GRID TO REMAIN AND BE PAINTED. NEW TILE ARMSTRONG DUNE 1773 2'X4' SQUARE EDGE LAY IN EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. 1. ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED AS REQUIRED SEE A-3A AND A-3B 2. ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC. SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE ALL ABANDON WIRING AND RE-CIRCUIT AS REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B 3. ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY AS A RESULT OF THIS WORK, SEE A-3A AND A-3B. 4. REFER TO SYMBOLS FOR ALL NEW AND EXISTING FIXTURES AND CEILINGS. 5. ALL EMERGENCY LIGHT FIXTURES AND CIRCUITING TO BE RETAINED PER ALL APPLICABLE CODES. EXISTING RECESSED LIGHT FIXTURE TO BE REMOVED U.O.N. EXISTING CEILING MTD. DIFFUSER EXISTING CEILING MTD. RETURN GRILLE B306 OFFICE EXISTING CEILING MTD. SMOKE DETECTOR 6. CONTRACTOR SHALL ENSURE THAT AT COMPLETION OF WORK ALL LIGHT FIXTURES ARE IN WORKING CONDITION, WITH OPERABLE LAMPS. APPROXIMATE EXISTING SPRINKLER HEAD LOCATION 7. EXISTING ILLUMINATED EXIST SIGN, ARROW INDICATE DIRECTION HATCH INDICATES FACE OF LETTERING ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS ARE TO BE REMOVED AND REPLACED AS INDICATED ON A-3A AND A-3B 8. SD B305 OFFICE EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. 9. EXISTING FIRE STROBE TO REMAIN U.N.O. B304 OFFICE ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS INDICATED ON SHEET A-3A AND A-3B. EXISTING CEILING SPEAKERS TO BE REMOVED AND REINSTALLED BY AVIS BUDGET GROUP (ABG) VENDOR. GC TO COORDINATE WITH ABG AND VENDOR. s t u d i o 1 2 0 0, LLC 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 10. EXISTING MOTION SENSORS TO BE REMOVED AND REINSTALLED BY GC COORDINATE WITH ABG. M EXISTING MICROPHONE IN CEILING TO REMAIN W EXISTING WIFI INTERNET BOOSTER C EXISTING CAMERA TO REMAIN 11. REMOVE ALL EXISTING CEILING TILE IN THE AREA OF WORK AND PAINT EXISTING GRID, PROTECT ALL EXISTING DEVICES SCHEDULED TO REMAIN. P EXISTING PROJECTOR TO REMAIN 12. EXIT SIGNS TO REMAIN. S EXISTING SPEAKERS/INTERCOM TO REMAIN B303 PHASE III OFFICE KEY NOTES: 1 REMOVE EXISTING CEILING GRID AT THIS LOCATION. B302 OFFICE B301 OFFICE B300 OFFICE A308 A307 A306 A305 A304 A303 A302 A301 A300 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONF. RM. 1 NO 01 A309 S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-2A_RCP.Demo.dwg, 11/20/2012 5:05:00 PM OFFICE 1 A310 A343 OFFICE OFFICE A327 A328 OFFICE OFFICE ISSUE FOR BID & PERMIT DATE 11.19.2012 A345 CONF. ROOM A311 A326 OFFICE OFFICE A342 OFFICE 1 A325 OFFICE A312 A329 A330 OFFICE CONF. RM. CONF. RM. A324 OFFICE A313 OFFICE PLAN B A341 CONF. RM. A323 A314 OFFICE OFFICE ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 A340 OFFICE A315 OFFICE 1 REFLECTED CEILING DEMOLITION PLAN (A) A316 A317 A318 A319 A320 A321 A322 OFFICE OFFICE OFFICE OFFICE CONF. RM. OFFICE OFFICE REFLECTED CEILING DEMOLITION PLAN (A) SCALE: 1/8" = 1'-0" 1 A-2A B313 B314 B315 B316 B317 OFFICE OFFICE OFFICE OFFICE OFFICE GENERAL NOTES: SYMBOLS SYM. TYPE EXISTING 2X4 CEILING GRID TO REMAIN AND BE PAINTED. NEW TILE ARMSTRONG DUNE 1773 2'X4' SQUARE EDGE LAY IN B318a EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. OFFICE 1. ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED AS REQUIRED SEE A-3A AND A-3B 2. ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC. SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE ALL ABANDON WIRING AND RE-CIRCUIT AS REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B 3. ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY AS A RESULT OF THIS WORK, SEE A-3A AND A-3B. 4. REFER TO SYMBOLS FOR ALL NEW AND EXISTING FIXTURES AND CEILINGS. 5. ALL EMERGENCY LIGHT FIXTURES AND CIRCUITING TO BE RETAINED PER ALL APPLICABLE CODES. EXISTING RECESSED LIGHT FIXTURE TO BE REMOVED U.O.N. EXISTING CEILING MTD. DIFFUSER S S S PHASE III B318b OFFICE EXISTING CEILING MTD. RETURN GRILLE EXISTING CEILING MTD. SMOKE DETECTOR 6. CONTRACTOR SHALL ENSURE THAT AT COMPLETION OF WORK ALL LIGHT FIXTURES ARE IN WORKING CONDITION, WITH OPERABLE LAMPS. APPROXIMATE EXISTING SPRINKLER HEAD LOCATION 7. ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS ARE TO BE REMOVED AND REPLACED AS INDICATED ON A-3A AND A-3B SD B319a OFFICE W EXISTING ILLUMINATED EXIST SIGN, ARROW INDICATE DIRECTION HATCH INDICATES FACE OF LETTERING S EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. B319b OFFICE S EXISTING FIRE STROBE TO REMAIN U.N.O. 9. ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS INDICATED ON SHEET A-3A AND A-3B. EXISTING CEILING SPEAKERS TO BE REMOVED AND REINSTALLED BY AVIS BUDGET GROUP (ABG) VENDOR. GC TO COORDINATE WITH ABG AND VENDOR. 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 10. EXISTING MOTION SENSORS TO BE REMOVED AND REINSTALLED BY GC COORDINATE WITH ABG. M EXISTING MICROPHONE IN CEILING TO REMAIN W EXISTING WIFI INTERNET BOOSTER C EXISTING CAMERA TO REMAIN 11. REMOVE ALL EXISTING CEILING TILE IN THE AREA OF WORK AND PAINT EXISTING GRID, PROTECT ALL EXISTING DEVICES SCHEDULED TO REMAIN. P EXISTING PROJECTOR TO REMAIN 12. EXIT SIGNS TO REMAIN. S EXISTING SPEAKERS/INTERCOM TO REMAIN B320 OFFICE 8. s t u d i o 1 2 0 0, LLC KEY NOTES: B321 OFFICE REMOVE EXISTING CEILING GRID AT THIS LOCATION. S B322 OFFICE B323 OFFICE C300 CONF. RM. S S C301 C302 C303 C304 C305 C306 C307 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE C308 S OFFICE C309 OFFICE S S NO S ISSUE DATE S 01 S S FOR BID & PERMIT 11.19.2012 C310 S OFFICE W S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-2B_RCP.Demo.dwg, 11/20/2012 5:05:09 PM E E E E C311 OFFICE PHASE I S E E E C343 E OFFICE C312 S C331 OFFICE OFFICE E E E E E E E E C313 OFFICE F A330 CONF. RM. C332 C330 CONF. RM. OFFICE S S S 4 S C329 C314 OFFICE OFFICE W PLAN A C328 OFFICE C315 OFFICE C327b OFFICE S ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 C316 S C327a OFFICE OFFICE S S REFLECTED CEILING DEMOLITION PLAN (B) REFLECTED CEILING DEMOLITION PLAN (B) SCALE: 1/8" = 1'-0" C326 C325 C324 C323 C322 C321 C320 C319 C318 C317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 1 A-2B B307 B308 B309 B310 B311 B312 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE B313 OFFIC GENERAL NOTES: SYMBOLS 1. ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED AS REQUIRED SEE A-3A AND A-3B EXISTING 2X4 CEILING GRID TO REMAIN AND BE PAINTED. NEW TILE ARMSTRONG DUNE 1773 2'X4' SQUARE EDGE LAY IN 2. ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC. SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE ALL ABANDON WIRING AND RE-CIRCUIT AS REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. 3. ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY AS A RESULT OF THIS WORK, SEE A-3A AND A-3B. 4. REFER TO SYMBOLS FOR ALL NEW AND EXISTING FIXTURES AND CEILINGS. 5. ALL EMERGENCY EMERGENCY LIGHT FIXTURES AND CIRCUITING TO BE RETAINED PER ALL APPLICABLE CODES. 6. CONTRACTOR SHALL ENSURE THAT AT COMPLETION OF WORK ALL LIGHT FIXTURES ARE IN WORKING CONDITION, WITH OPERABLE LAMPS, ALL AT SAME COLOR TEMPERATURE. 7. ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS ARE TO BE REMOVED AND REPLACED AS INDICATED ON A-3A AND A-3B SYM. TYPE EXISTING RECESSED LIGHT FIXTURE TO BE REMOVED U.O.N. EXISTING CEILING MTD. DIFFUSER B306 OFFICE EXISTING CEILING MTD. RETURN GRILLE SD APPROXIMATE EXISTING SPRINKLER HEAD LOCATION 5 B305 EXISTING CEILING MTD. SMOKE DETECTOR EXISTING ILLUMINATED EXIST SIGN, ARROW INDICATE DIRECTION HATCH INDICATES FACE OF LETTERING OFFICE 8. ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS INDICATED ON SHEET A-3A AND A-3B. 9. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF POTENTIAL OR ACTUAL CONFLICTS W/ LIGHTING AND ABOVE CEILING DUCTS, PIPES, ETC. EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. NEW 2'X4' LIGHTOLIER COFFAIRE II DIRECT/INDIRECT RECESSED CFH2GPF232277HI 3 LAMP SUPER T-8. B304 OFFICE NEW 2'X2' LIGHTOLIER COFFAIRE II DIRECT/INDIRECT RECESSED CFH2GPF217277SBGLR 3 LAMP T-8. NEW PENDANT LIGHTING TBD B303 s t u d i o 1 2 0 0, LLC 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 10. PLANS INDICATE EXISTING LOCATIONS FOR SPRINKLERS GC TO COORDINATE RELOCATION OF SPRINKLERS HEADS, HVAC DIFFUSERS, HVAC RETURN AIR GRILLS AND OTHER CEILING MTD DEVICES AS REQUIRED BY NEW LIGHTING LAYOUT. OFFICE LYTECASTER 5' DIA. LED RECESSED DOWN LIGHT. 277V / DIMMABLE / 900 LUMEN 3500 K LAMP / FRAME IN KIT 1001LED09N35D2 / WHITE CONE SHEET NOTES: EXISTING FIRE STROBE TO REMAIN U.N.O. B302 M OFFICE W 1 PATCH AND REPAIR GRID TO LIKE NEW CONDITIONS AS REQUIRED PRIOR TO PAINTING AREA OF DEMOLITION. 2 CONTRACTOR SHALL VERIFY GRID & PROPOSED LIGHT CONDITION IN THIS AREA. CONTRACTOR SHALL SHIFT LIGHT TO NEXT BAY IF NECESSARY. 3 CONTRACTOR SHALL SHIFT EXISTING DIFFUSER OR RETURN AS REQUIRED BY NEW LIGHTING LAY OUT. 4 CONTRACTOR SHALL RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED BY NEW LIGHTING LAY OUT. 5 CONTRACTOR SHALL RELOCATE SMOKE DETECTOR AS REQUIRED BY NEW LIGHTING LAY OUT. 6 NEW GRID AND TILE AT THIS AREA. 7 EXTEND EXISTING GRID AS REQUIRED. 8 EXISTING GYP. BD. SOFFIT TO REMAIN. 9 EXISTING GRID AND TILE TO REMAIN IN THIS AREA. EXISTING MICROPHONE IN CEILING TO REMAIN EXISTING WIFI INTERNET BOOSTER C EXISTING CAMERA TO REMAIN B301 P OFFICE S EXISTING PROJECTOR TO REMAIN EXISTING SPEAKERS/INTERCOM TO REMAIN PHASE III B300 OFFICE A308 A307 A306 A305 A304 A303 A302 A301 A300 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONF. RM. 10 DEMOLISHED CEILING GRID AND PROPOSED CEILING GRID HEIGHTS DIFFER, GENERAL CONTRACTOR TO VERIFY CLEARANCE ABOVE CEILING FOR PROPOSED EQUIPMENT AND LIGHTING, CONTACT ARCHITECT TO REVIEW RESOLUTION OF ANY CONFLICTS PRIOR TO INSTALLATION OF NEW MATERIAL. 6 NO 01 A309 S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-3A_RCP.dwg, 11/20/2012 5:05:20 PM OFFICE 6 4 A310 A343 OFFICE OFFICE A327 A328 OFFICE OFFICE ISSUE FOR BID & PERMIT DATE 11.19.2012 A345 CONF. ROOM A311 A326 OFFICE OFFICE A342 10 1 OFFICE 6 A325 OFFICE 4 4 A312 A329 A330 OFFICE CONF. RM. CONF. RM. A324 OFFICE 4 5 A313 OFFICE PLAN B 8 A341 CONF. RM. 8 A323 A314 OFFICE OFFICE 8 A340 ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 OFFICE 4 A315 OFFICE 6 REFLECTED CEILING PLAN (A) A316 A317 A318 A319 A320 A321 A322 OFFICE OFFICE OFFICE OFFICE CONF. RM. OFFICE OFFICE REFLECTED CEILING PLAN (A) SCALE: 1/8" = 1'-0" 1 A-3A B312 B313 B314 B315 B316 B317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE GENERAL NOTES: SYMBOLS 1. ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED AS REQUIRED SEE A-3A AND A-3B EXISTING 2X4 CEILING GRID TO REMAIN AND BE PAINTED. NEW TILE ARMSTRONG DUNE 1773 2'X4' SQUARE EDGE LAY IN 2. ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC. SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE ALL ABANDON WIRING AND RE-CIRCUIT AS REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. 3. ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR RELOCATING ANY AS A RESULT OF THIS WORK, SEE A-3A AND A-3B. 4. REFER TO SYMBOLS FOR ALL NEW AND EXISTING FIXTURES AND CEILINGS. 5. ALL EMERGENCY EMERGENCY LIGHT FIXTURES AND CIRCUITING TO BE RETAINED PER ALL APPLICABLE CODES. SYM. B318a OFFICE TYPE EXISTING RECESSED LIGHT FIXTURE TO BE REMOVED U.O.N. EXISTING CEILING MTD. DIFFUSER S S S B318b EXISTING CEILING MTD. RETURN GRILLE OFFICE SD B319a APPROXIMATE EXISTING SPRINKLER HEAD LOCATION OFFICE W EXISTING CEILING MTD. SMOKE DETECTOR EXISTING ILLUMINATED EXIST SIGN, ARROW INDICATE DIRECTION HATCH INDICATES FACE OF LETTERING PHASE III S CONTRACTOR SHALL ENSURE THAT AT COMPLETION OF WORK ALL LIGHT FIXTURES ARE IN WORKING CONDITION, WITH OPERABLE LAMPS, ALL AT SAME COLOR TEMPERATURE. 7. ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS ARE TO BE REMOVED AND REPLACED AS INDICATED ON A-3A AND A-3B 8. ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS INDICATED ON SHEET A-3A AND A-3B. 9. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY OF POTENTIAL OR ACTUAL CONFLICTS W/ LIGHTING AND ABOVE CEILING DUCTS, PIPES, ETC. EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO BE REMOVED U.N.O. B319b S 6. NEW 2'X4' LIGHTOLIER COFFAIRE II DIRECT/INDIRECT RECESSED CFH2GPF232277HI 3 LAMP SUPER T-8. OFFICE NEW 2'X2' LIGHTOLIER COFFAIRE II DIRECT/INDIRECT RECESSED CFH2GPF217277SBGLR 3 LAMP T-8. B320 NEW PENDANT LIGHTING TBD OFFICE LYTECASTER 5' DIA. LED RECESSED DOWN LIGHT. 277V / DIMMABLE / 900 LUMEN 3500 K LAMP / FRAME IN KIT 1001LED09N35D2 / WHITE CONE B321 OFFICE M W CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 10. PLANS INDICATE EXISTING LOCATIONS FOR SPRINKLERS GC TO COORDINATE RELOCATION OF SPRINKLERS HEADS, HVAC DIFFUSERS, HVAC RETURN AIR GRILLS AND OTHER CEILING MTD DEVICES AS REQUIRED BY NEW LIGHTING LAYOUT. SHEET NOTES: 1 PATCH AND REPAIR GRID TO LIKE NEW CONDITIONS AS REQUIRED PRIOR TO PAINTING AREA OF DEMOLITION. 2 CONTRACTOR SHALL VERIFY GRID & PROPOSED LIGHT CONDITION IN THIS AREA. CONTRACTOR SHALL SHIFT LIGHT TO NEXT BAY IF NECESSARY. 3 CONTRACTOR SHALL SHIFT EXISTING DIFFUSER OR RETURN AS REQUIRED BY NEW LIGHTING LAY OUT. 4 CONTRACTOR SHALL RELOCATE EXISTING SPRINKLER HEAD AS REQUIRED BY NEW LIGHTING LAY OUT. 5 CONTRACTOR SHALL RELOCATE SMOKE DETECTOR AS REQUIRED BY NEW LIGHTING LAY OUT. 6 NEW GRID AND TILE AT THIS AREA. 7 EXTEND EXISTING GRID AS REQUIRED. 8 EXISTING GYP. BD. SOFFIT TO REMAIN. 9 EXISTING GRID AND TILE TO REMAIN IN THIS AREA. EXISTING MICROPHONE IN CEILING TO REMAIN EXISTING WIFI INTERNET BOOSTER S C EXISTING CAMERA TO REMAIN B322 P OFFICE EXISTING PROJECTOR TO REMAIN S EXISTING SPEAKERS/INTERCOM TO REMAIN B323 OFFICE C300 CONF. RM. C301 C302 C303 C304 C305 C306 C307 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE PHASE I S 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com EXISTING FIRE STROBE TO REMAIN U.N.O. R S s t u d i o 1 2 0 0, LLC 10 DEMOLISHED CEILING GRID AND PROPOSED CEILING GRID HEIGHTS DIFFER, GENERAL CONTRACTOR TO VERIFY CLEARANCE ABOVE CEILING FOR PROPOSED EQUIPMENT AND LIGHTING, CONTACT ARCHITECT TO REVIEW RESOLUTION OF ANY CONFLICTS PRIOR TO INSTALLATION OF NEW MATERIAL. C308 S OFFICE C309 OFFICE S S NO S S 01 S S ISSUE FOR BID & PERMIT DATE 11.19.2012 C310 S OFFICE W 2 E E E E C311 S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-3B_RCP.dwg, 11/20/2012 5:05:32 PM A-7 OFFICE S E E E C343 E OFFICE C312 S C331 OFFICE OFFICE E E E E E E E E C313 OFFICE F A330 C332 C330 CONF. RM. CONF. RM. OFFICE R S S S 4 S S C314 C329 PLAN A OFFICE OFFICE W R C328 OFFICE C315 OFFICE C327b OFFICE R S ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 6 C316 S C327a OFFICE S 6 OFFICE S 6 6 REFLECTED CEILING PLAN (B) REFLECTED CEILING PLAN (B) SCALE: 1/8" = 1'-0" C326 C325 C324 C323 C322 C321 C320 C319 C318 C317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 1 A-3B PAINT, WALL COVERING AND WINDOW TREATMENT SCHEDULE TAG P-1 MANUFACTURER COLOR BENJAMIN MOORE ITEM # FINISH 1078 FLAT AT WALLS DOOR & FRAMES SEMI-GLOSS DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 HILLCREST TAN B307 B308 B309 B310 B311 B312 B313 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONTACT TAG P-2 BENJAMIN MOORE BRIDGEWATER TAN 1096 FLAT FINISH DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 P-3 BENJAMIN MOORE OAKWOOD MANOR 1095 FLAT FINISH DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 P-4 NOT USED NOT USED NOT USED MANUFACTURER NAME COLOR/SIZE ITEM # CONTACT WB-1 ARMSTRONG NOT USED WB-2 JOHNSONITE 4" STRAIGHT VINYL BASE CONT. COIL 285 MORNING LIGHT Karen Levey-Lynch PHONE: (800) 899-8916 x 769 WB-3 JOHNSONITE 4" STRAIGHT VINYL BASE CONT. COIL 129 SILK Karen Levey-Lynch PHONE: (800) 899-8916 x 769 WB-4 NOT USED NOT USED 1 1 P-5 GENERAL NOTES: WALL BASE SCHEDULE NOT USED B306 WB-5 NOT USED NOT USED WB-6 JOHNSONITE NOT USED WB-7 ARMSTRONG 4" STRAIGHT VINYL BASE CONT. COIL 1. CONTRACTOR SHALL FIELD VERIFY CONDITIONS AND NOTIFY ARCHITECT OF ANY CHANGES. 2. ALL FLOORS SHOULD BE SKIM COATED AS NECESSARY TO ACHIEVE CLEAN SURFACES SO THAT BLEMISHES DO NOT TELEGRAPH THROUGH FINISH MATERIAL. 3. ALL WALLS SHALL BE MADE READY TO RECEIVE SCHEDULED FINISH. I.E.: FINISHED LAYER OF GYP. BD. AS REQUIRED. 4. ALL FINISHES SHALL BE APPLIED FREE OF SAGS, RUNS, STREAKS, BRUSH OR ROLLER MARKS, ETC. 5. CONTRACTOR TO RECEIVE FINAL APPROVAL ON MATERIALS FROM ARCHITECT PRIOR TO ORDERING. CONTRACTOR TO VERIFY ALL PRODUCT LEAD TIMES AND ORDER MATERIAL ACCORDINGLY. OFFICE P-6 NOT USED NOT USED 16 JENNIFER WALL PHONE: 800-356-9301 x 8288 SAND 6. FLOOR FINISH TRANSITIONS AT DOORS SHALL BE CENTERED UNDER DOOR WHERE APPLICABLE. 7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATION. 8. ALL TRIM PAINT TO RECEIVE SEMI-GLOSS FINISH. ALL WALL PAINT TO RECEIVE FLAT FINISH. ALL CEILING PAINT TO RECEIVE FLAT FINISH. WB-8 P-7 NOT USED NOT USED B305 P-8 P-9 BENJAMIN MOORE SUPERWHITE NOT USED DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 FLAT FINISH WALL TILE SCHEDULE OFFICE C-1 P-2 WB-2 TAG T-1 B304 P-10 P-11 BENJAMIN MOORE ELK HORN BENJAMIN MOORE AF-105 TBD FLAT FINISH TBD TBD ITEM # NOT USED TBD WC-2 TBD WC-3 TBD P-10 P-10 P-10 P-10 T-2 NOT USED NOT USED TBD T-3 B303 T-3 DALTILE TAG B301 P665 B300 MANUFACTURER SS-1 CORIAN SS-2 NOT USED SS-3 CAESARSTONE OFFICE A308 A307 A306 A305 A304 A303 A302 A301 A300 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE CONF. RM. P-10 P-10 P-10 P-10 PL-1 NOT USED PL-2 FORMICA W.C. DALTILE KELLY HOLLAND-YOUNG PHONE: 908-340-8400 14. FOR FLOORING REMOVAL, SEE SHEET A-1A AND A-1B. NAME COLOR SOLID SURFACE COUNTERTOP - CANYON SOLID SURFACE COUNTERTOP TBD TBD C-1 P-2 WB-2 C-1 P-3 WB-3 C-2 5342-58 MANUFACTU RER COLOR/SIZE NAME P-2 WB-2 VT-1 C-2 PLASTIC LAMINATE EARTH CONTACT DOLAN & TRAYNOR CONTACT: CAROL DE VIETRO PHONE: 800-696-8760 WENDIE GOTTE CONTACT: CAESARSTONE PHONE: (973) 474-6234 CONTACT: SAMANTHA SMITH PHONE: 484-241-7300 FLOOR SCHEDULE TAG C-1 P-3 WB-3 AMTICO LINEAR J+J INVISION CARPET TILE BROKEN SLATE MODULAR (7950) BENTLEY PRINCE STREET INTERNATIONAL GLAMOUR BROADLOOM AR0AL A42 COLOR: LINEAR MOCHA SIZE: 9" x 36" COLOR: 342 COPPER INSTALLATION: QUARTER TURNED SIZE: 24" x 24" MATERIAL CLASSIFICATION - CONTACT CONTACT: FLORENCE GARAFFA PHONE: 732-606-9059 PROVIDE VINYL CARPET TO VINYL TILE TRANSITION STRIP WHERE REQUIRED. ARCHITECT TO SELECT COLOR FROM MANUF. STANDARD SELECTION OFFICE C-2 A310 P-3 WB-3 A327 A328 OFFICE OFFICE CLASS 1 CONTACT: SCOTT CUCCI PHONE: 1.800.241.4586 x 7949 A-7 C-2 8IG34 0630R 7 STAR RESORTS 880110 CLASS 1 CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 12' - 6" WIDTH. 1 P-10 P-10 P-3 WB-3 A345 2 OFFICE C-2 P-3 WB-3 P-10 P-10 SS-1 OFFICE C-2 P-10 WB-7 P-10 P-10 1 ACCENT WALL BAND THAT IS CURRENTLY ALIGNED WITH THE DOOR FRAME AT OPEN OFFICE AREAS SHALL BE REMOVED. PATCH WALL AS REQUIRED PRIOR TO PAINTING. 2 REMOVE EXISTING PANTRY FLOORING. PATCH SLAB AS REQUIRED TO RECEIVE NEW VINYL TILE. 4 EXISTING WALL COVERING AND BASE TO REMAIN. SEE SHEET A-1A FOR ALTERNATE IF REQUIRED. 5 QUANTITY OF C-4 CARPET TO BE FIELD VERIFIED. EXISTING CARPET TO REMAIN AND PATCH WITH NEW AS REQUIRED BASED ON FURNITURE RELOCATION. 6 REPLACE WITH NEW WB-2 WALL BASE. 7 REPAINT EXISTING CONVECTOR COVER P-11. NO ISSUE FOR BID & PERMIT DATE 11.19.2012 FINISH SYMBOLS FLOOR FINISH P-10 P-10 P-3 WB-3 CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 NOT USED 59224 COLOR: SORBET 70135 TO MATCH EXISTING SIZE: 24" x 24" CONTACT: MICHAEL MALFI PHONE: 908-208-0389 CONTACT: MICHAEL MALFI PHONE: 908-208-0389 SHAW CONTRACT GROUP C-5 SHAW CONTRACT GROUP CAMBRIC 5A050 COLOR: LENO 50172 TO MATCH EXISTING BROADLOOM C-6 BENTLEY PRINCE STREET HOLLYWOOD SEQUEL BROADLOOM 8HQ32 0630R COLOR: GATEWOOD PARK 801507 CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 C-7 BENTLEY PRINCE STREET KINGS ROAD BROADLOOM 8KR42 0630R TBD CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 STRAIGHTFORWARD TILE A325 P-3 WB-3 6 A312 A329 A330 OFFICE CONF. RM. CONF. RM. P-3 WB-3 C-5 DOOR FINISH C-4 OFFICE 5 COUNTER FINISH DOOR FRAME FINISH A342 P-10 P-10 NOT USED A326 OFFICE VT-1 T-3 C-5 C-3 P-10 P-10 CONF. ROOM A311 SHEET NOTES: WALL BASE FINISH OFFICE C-5 17. REPAINT EXISTING CONVECTOR COVERS IN PERIMETER OFFICES TO MATCH ADJACENT WALL U.O.N. WALL FINISH A343 OFFICE 16. ALL PERIMETER OFFICES TO RECEIVE C-2 CARPET WITH P-3 PAINT AND WB-3. 01 1 A309 13. MATERIAL SHALL BE ORDERED FOR ALL (3) PHASES CONCURRENTLY SO DYE LOT IS CONSISTENT. COORDINATE WITH TENANT ON STORING OF MATERIALS. 3 EXISTING FINISHES TO REMAIN AT THIS LOCATION. P-10 WB-7 1 ALL FACE AND SIDES OF GYP. BD. CEILINGS SHALL BE PAINTED (P-8) U.O.N. 15. DOOR FRAMES TO BE PAINTED TO MATCH ADJACENT COLOR U.O.N., SEMI-GLOSS FINISH. REFER TO SHEET NOTES #1 BELOW FOR FURTHER DETAIL. OFFICE PHASE III S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-4A_Finish.dwg, 11/20/2012 5:05:43 PM MARACAS GLASS LAKE SHORES BLEND GLOSSY SIZE: 1" x 1" GROUT: HYDROMENT COLOR:LINEN H163 SURFACE SCHEDULE LEO ALESSI VERTICAL INTERIOR PRODUCTS PHONE: 212-991-4172 TBD Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 12. IF VINYL WALL COVERING EXISTS, REMOVE, PATCH AND REPAIR TO RECEIVE NEW PAINT U.O.N. B302 TBD CERITFICATE OF AUTHORIZATION # AC-710 10. REFER TO A-5 FOR ALL INTERIOR ELEVATIONS. SS-1 1 ARENSON 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com 11. ALL MILLWORK SHALL BE (PL-2) PLASTIC LAMINATE UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS FOR MORE INFORMATION. OFFICE WT-1 CONTACT NOT USED OFFICE WC-1 COLOR VT-1 OFFICE DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 NAME 9. NOT USED DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 MANUFACTURER s t u d i o 1 2 0 0, LLC A324 FLOOR TRANSITION OFFICE A313 OFFICE C-5 P-3 WB-3 C-4 P-2 WB-2 3 A341 CONF. RM. A323 1 A314 3 4 OFFICE OFFICE 3 3 6 A340 A315 6 1 OFFICE C-5 3 P-3 WB-3 C-5 P-3 WB-3 C-5 P-3 WB-3 ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 3 OFFICE 6 C-5 P-3 WB-3 3 3 3 FINISH PLAN (A) A316 A317 A318 A319 A320 A321 A322 OFFICE OFFICE OFFICE OFFICE CONF. RM. OFFICE OFFICE FINISH PLAN (A) SCALE: 1/8" = 1'-0" 1 A-4A B312 B313 B314 B315 B316 B317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE PAINT, WALL COVERING AND WINDOW TREATMENT SCHEDULE TAG MANUFACTURER COLOR ITEM # FINISH P-1 BENJAMIN MOORE HILLCREST TAN 1078 FLAT AT WALLS DOOR & FRAMES SEMI-GLOSS DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 P-2 BENJAMIN MOORE BRIDGEWATER TAN 1096 FLAT FINISH DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 CONTACT P-3 BENJAMIN MOORE OAKWOOD MANOR 1095 FLAT FINISH DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 B318a OFFICE PHASE III NOT USED P-4 WALL BASE SCHEDULE P-5 NOT USED NOT USED OFFICE C-1 P-2 WB-2 P-6 P-10 WB-7 NOT USED WB-1 ARMSTRONG NOT USED WB-2 JOHNSONITE 4" STRAIGHT VINYL BASE CONT. COIL 285 MORNING LIGHT Karen Levey-Lynch PHONE: (800) 899-8916 x 769 WB-3 JOHNSONITE 4" STRAIGHT VINYL BASE CONT. COIL 129 SILK Karen Levey-Lynch PHONE: (800) 899-8916 x 769 ITEM # WB-4 NOT USED NOT USED WB-5 NOT USED NOT USED WB-6 JOHNSONITE NOT USED ARMSTRONG 4" STRAIGHT VINYL BASE CONT. COIL CONTACT P-7 NOT USED P-8 1. CONTRACTOR SHALL FIELD VERIFY CONDITIONS AND NOTIFY ARCHITECT OF ANY CHANGES. 2. ALL FLOORS SHOULD BE SKIM COATED AS NECESSARY TO ACHIEVE CLEAN SURFACES SO THAT BLEMISHES DO NOT TELEGRAPH THROUGH FINISH MATERIAL. 3. ALL WALLS SHALL BE MADE READY TO RECEIVE SCHEDULED FINISH. I.E.: FINISHED LAYER OF GYP. BD. AS REQUIRED. 4. ALL FINISHES SHALL BE APPLIED FREE OF SAGS, RUNS, STREAKS, BRUSH OR ROLLER MARKS, ETC. 5. CONTRACTOR TO RECEIVE FINAL APPROVAL ON MATERIALS FROM ARCHITECT PRIOR TO ORDERING. CONTRACTOR TO VERIFY ALL PRODUCT LEAD TIMES AND ORDER MATERIAL ACCORDINGLY. 16 SAND 6. FLOOR FINISH TRANSITIONS AT DOORS SHALL BE CENTERED UNDER DOOR WHERE APPLICABLE. 7. ALL MATERIALS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATION. 8. ALL TRIM PAINT TO RECEIVE SEMI-GLOSS FINISH. ALL Nancy Dougherty, AIA, LEED WALL PAINT TO RECEIVE FLAT FINISH. ALL CEILING NJ-AI 14861/NY-025099/CT-ARI.0011798 PAINT TO RECEIVE FLAT FINISH. 9. ALL FACE AND SIDES OF GYP. BD. CEILINGS SHALL BE PAINTED (P-8) U.O.N. s t u d i o 1 2 0 0, LLC 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com NOT USED BENJAMIN MOORE SUPERWHITE FLAT FINISH WALL TILE SCHEDULE DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 TAG MANUFACTURER NAME COLOR ITEM # CONTACT CERITFICATE OF AUTHORIZATION # AC-710 B319b OFFICE P-9 NOT USED NOT USED T-1 NOT USED NOT USED 10. REFER TO A-5 FOR ALL INTERIOR ELEVATIONS. 1 P-10 BENJAMIN MOORE ELK HORN AF-105 FLAT FINISH DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 TBD DIANA RATAZZI PHONE: 877-712-6567 CELL: 914-261-8603 T-2 B320 OFFICE P-11 BENJAMIN MOORE WC-1 TBD WC-2 TBD TBD TBD T-3 NOT USED DALTILE 11. ALL MILLWORK SHALL BE (PL-2) PLASTIC LAMINATE UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS FOR MORE INFORMATION. NOT USED MARACAS GLASS P665 B321 OFFICE WC-3 LAKE SHORES BLEND GLOSSY SIZE: 1" x 1" GROUT: HYDROMENT COLOR:LINEN H163 12. IF VINYL WALL COVERING EXISTS, REMOVE, PATCH AND REPAIR TO RECEIVE NEW PAINT U.O.N. DALTILE KELLY HOLLAND-YOUNG PHONE: 908-340-8400 ARENSON TBD TBD SURFACE SCHEDULE LEO ALESSI VERTICAL INTERIOR PRODUCTS PHONE: 212-991-4172 TBD OFFICE PHASE I B323 TAG MANUFACTURER NAME COLOR SS-1 CORIAN SOLID SURFACE COUNTERTOP SS-2 NOT USED SS-3 CAESARSTONE PL-1 NOT USED PL-2 FORMICA - CANYON CONTACT DOLAN & TRAYNOR CONTACT: CAROL DE VIETRO PHONE: 800-696-8760 C300 CONF. RM. C301 C302 C303 C304 C305 C306 C307 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE P-10 WB-7 SOLID SURFACE COUNTERTOP PLASTIC LAMINATE TBD 5342-58 TBD EARTH WENDIE GOTTE CONTACT: CAESARSTONE PHONE: (973) 474-6234 CONTACT: SAMANTHA SMITH PHONE: 484-241-7300 OFFICE TAG 1 VT-1 C309 P-2 WB-2 MANUFACTU RER AMTICO COLOR/SIZE NAME LINEAR AR0AL A42 OFFICE P-10 WB-7 C-1 C310 P-10 P-10 J+J INVISION CARPET TILE OFFICE C-2 BENTLEY PRINCE STREET 16. ALL PERIMETER OFFICES TO RECEIVE C-2 CARPET WITH P-3 PAINT AND WB-3. BROKEN SLATE MODULAR (7950) INTERNATIONAL GLAMOUR BROADLOOM SHEET NOTES: 1 ACCENT WALL BAND THAT IS CURRENTLY ALIGNED WITH THE DOOR FRAME AT OPEN OFFICE AREAS SHALL BE REMOVED. PATCH WALL AS REQUIRED PRIOR TO PAINTING. 2 REMOVE EXISTING PANTRY FLOORING. PATCH SLAB AS REQUIRED TO RECEIVE NEW VINYL TILE. 3 EXISTING FINISHES TO REMAIN AT THIS LOCATION. FLOOR SCHEDULE C308 15. DOOR FRAMES TO BE PAINTED TO MATCH ADJACENT COLOR U.O.N., SEMI-GLOSS FINISH. REFER TO SHEET NOTES #1 BELOW FOR FURTHER DETAIL. 17. REPAINT EXISTING CONVECTOR COVERS IN PERIMETER OFFICES TO MATCH ADJACENT WALL U.O.N. OFFICE C-1 13. MATERIAL SHALL BE ORDERED FOR ALL (3) PHASES CONCURRENTLY SO DYE LOT IS CONSISTENT. COORDINATE WITH TENANT ON STORING OF MATERIALS. 14. FOR FLOORING REMOVAL, SEE SHEET A-1A AND A-1B. TBD WT-1 B322 8IG34 0630R COLOR: LINEAR MOCHA SIZE: 9" x 36" MATERIAL CLASSIFICATION - CONTACT CONTACT: FLORENCE GARAFFA PHONE: 732-606-9059 PROVIDE VINYL CARPET TO VINYL TILE TRANSITION STRIP WHERE REQUIRED. ARCHITECT TO SELECT COLOR FROM MANUF. STANDARD SELECTION 4 EXISTING WALL COVERING AND BASE TO REMAIN. SEE SHEET A-1A FOR ALTERNATE IF REQUIRED. 5 QUANTITY OF C-4 CARPET TO BE FIELD VERIFIED. EXISTING CARPET TO REMAIN AND PATCH WITH NEW AS REQUIRED BASED ON FURNITURE RELOCATION. 6 REPLACE WITH NEW WB-2 WALL BASE. NO ISSUE DATE 7 REPAINT EXISTING CONVECTOR COVER P-11. COLOR: 342 COPPER INSTALLATION: QUARTER TURNED SIZE: 24" x 24" CLASS 1 7 STAR RESORTS 880110 CLASS 1 01 FOR BID & PERMIT 11.19.2012 CONTACT: SCOTT CUCCI PHONE: 1.800.241.4586 x 7949 FINISH SYMBOLS CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 12' - 6" WIDTH. FLOOR FINISH C311 1 OFFICE S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-4B_Finish.dwg, 11/20/2012 5:05:55 PM GENERAL NOTES: JENNIFER WALL PHONE: 800-356-9301 x 8288 WB-8 OFFICE P-10 P-10 NAME WB-7 NOT USED B319a P-10 P-10 MANUFACTURER NOT USED 1 B318b COLOR/SIZE TAG WALL FINISH WALL BASE FINISH P-10 P-10 C-3 NOT USED CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 NOT USED C343 COUNTER FINISH OFFICE P-10 P-10 C331 C312 2 P-10 P-10 OFFICE OFFICE T-3 SS-1 C-4 SHAW CONTRACT GROUP STRAIGHTFORWARD TILE 59224 VT-1 P-10 P-10 A330 C332 C330 CONF. RM. CONF. RM. OFFICE CONTACT: MICHAEL MALFI PHONE: 908-208-0389 CONTACT: MICHAEL MALFI PHONE: 908-208-0389 DOOR FRAME FINISH DOOR FINISH FLOOR TRANSITION C-5 SHAW CONTRACT GROUP CAMBRIC 5A050 COLOR: LENO 50172 TO MATCH EXISTING BROADLOOM C-6 BENTLEY PRINCE STREET HOLLYWOOD SEQUEL BROADLOOM 8HQ32 0630R COLOR: GATEWOOD PARK 801507 CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 C-7 BENTLEY PRINCE STREET KINGS ROAD BROADLOOM 8KR42 0630R TBD CONTACT: SUSAN LANE PHONE: (800) 423-4709 x5213 C313 OFFICE COLOR: SORBET 70135 TO MATCH EXISTING SIZE: 24" x 24" P-10 WB-7 C329 C314 OFFICE OFFICE C328 OFFICE C-1 P-2 WB-2 C315 OFFICE 1 C327b 1 OFFICE ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 C316 C327a OFFICE OFFICE 1 FINISH PLAN (B) FINISH PLAN (B) SCALE: 1/8" = 1'-0" C326 C325 C324 C323 C322 C321 C320 C319 C318 C317 OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE 1 A-4B 6 1/4" 6 1/4" 2'-6" s t u d i o 1 2 0 0, LLC 8 9 8 9 8 10 9 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com 10 4 6 CERITFICATE OF AUTHORIZATION # AC-710 10 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 5 7 3 FLOOR PLAN - PANTRY 3 2 FLOOR PLAN - PANTRY 2 SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" P-10 P-10 P-10 PAPER TOWEL DISPENSER BOBRICK B-2860 SCHLUTER - JOLLY 1/4" A60 AK ANODIZED ALUMINUM OR EQUAL P-10 EXISTING SOFFIT TO REMAIN EXISTING SOFFIT TO REMAIN P-10 PAPER TOWEL DISPENSER BOBRICK B-2860 PAPER TOWEL DISPENSER BOBRICK B-2860 ADA BUILDING STANDARD SINK & FAUCET, SEE SECTION FOR MODEL NUMBERS ADA BUILDING STANDARD SINK & FAUCET, SEE SECTION FOR MODEL NUMBERS SCHLUTER - JOLLY - 1/4" A60 AK ANODIZED ALUMINUM OR EQUAL WATER DISPENSER BY OWNER SEE EQUIPMENT SCHEDULE PROVIDE 1/2" DIA. HOLE FOR WATERLINE. SS-3 MICROWAVE BY OWNER SEE EQUIPMENT SCHEDULE SS-3 UNDER COUNTER FRIDGE BY OWNER SEE EQUIPMENT SCHEDULE 3'-8" TRASH WOOD FILLER TO MATCH CABINETS AS REQUIRED. PL-2 REF. 2'-10" PL-2 UNDER COUNTER FRIDGE (FOREGROUND) SEE EQUIPMENT SCHEDULE TRASH 2'-10" 3'-8" UNDER COUNTER FRIDGE BY OWNER SEE EQUIPMENT SCHEDULE REF. SS-3 4" 4" MICROWAVE BY OWNER SEE EQUIPMENT SCHEDULE T-3 WATER DISPENSER BY OWNER SEE EQUIPMENT SCHEDULE PROVIDE 1/2" DIA. HOLE FOR WATERLINE. 4" WATER DISPENSER BY OWNER SEE EQUIPMENT SCHEDULE PROVIDE 1/2" DIA. HOLE FOR WATERLINE. 2'-0" T-3 2'-0" T-3 SCHLUTER - JOLLY - 1/4" A60 AK ANODIZED ALUMINUM OR EQUAL 2'-0" EXISTING SOFFIT TO REMAIN PL-2 PL-2 REF. 2'-10" P-10 MICROWAVE BY OWNER SEE EQUIPMENT SCHEDULE 1 FLOOR PLAN - PANTRY 1 PL-2 NO 01 8 9 8 10 11.19.2012 9 10 2'-0 1/8" 3'-0" HOLD 2'-6" 6 INTERIOR ELEVATIONS - PANTRY 3 1'-6" 3'-6" HOLD 5 INTERIOR ELEVATIONS - PANTRY 2 SCALE: 1" = 1'-0" 2'-1 1/4" 1'-5" 1'-2 1/2" 3'-6" HOLD 1'-5" 4 INTERIOR ELEVATIONS - PANTRY 1 SCALE: 1" = 1'-0" SCALE: 1" = 1'-0" P-10 SCHLUTER - JOLLY 1/4" A60 AK ANODIZED ALUMINUM OR EQUAL 2'-6" REFER TO ELEVATIONS FOR WALL FINISH. SCALE: 1" = 1'-0" 10 DETAIL @ ADA SINK SCALE: 1" = 1'-0" 5 1/2" 1 1/2" 4" PL-2 EQ. HEAVY DUTY FULL EXTENSION GLIDES, TYP. WHITE MELAMINE INTERIOR (TYP.) 4" PLASTIC LAMINATE TOEKICK. 3" 9 DETAIL @ CABINET DRAWERS SCALE: 1" = 1'-0" INTERIOR ELEVATIONS 10 2'-0" DETAIL @ TRASH BIN ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 REFRIGERATOR BY OWNER "OUTWATER" PULLS MODEL #7030-SC (TYP.) NOTE: G.C. TO COORDINATE SINK CLEARANCES WITH MILLWORK. 3" TRASH PLASTIC LAMINATE DRAWER FACES (FULL OVERLAY). 4" 4" 4" 4" 4" PLASTIC LAMINATE TOEKICK. PLASTIC LAMINATE CABINET FRONT FINISHED PLASTIC LAMINATE PANEL BOTH SIDES/ REAR TO MATCH EXTERIOR PLASTIC LAMINATE INTERIOR (TYP.) SCHEDULED COUNTER TOP. EQ. 1'-11" 2'-4 1/2" RUBBERMAID COMMERCIAL WASTE BASKET 2'-6" MAX HEIGHT GRAY REFER TO A-0 FOR ACCESSIBILITY CLEARANCES 2'-10" PLASTIC LAMINATE CABINETRY 2'-0" 7" 1 1/2" 4" "OUTWATER" PULLS MODEL #7030-SC (TYP.) NOTE: G.C TO COORDINATE TRASH BIN CLEARANCE WITH CABINET WIDTH & DEPTH COUNTER TOP. SEE ELEVATIONS FOR SURFACE MATERIAL AND FINISH SCHEDULE FOR MORE INFORMATION. SS-3 4" BACKSPLASH TO MATCH COUNTERTOP EQ. 2'-0" SCHEDULED COUNTER TOP W/ 9" DIA. TRASH HOLE 5 1/2" 1 1/2" 1'-11" 4" 2'-0" 4" 4" BACKSPLASH TO MATCH COUNTERTOP REFER TO ELEVATIONS FOR WALL FINISH. UNDERMOUNT ADA SINK- ELKAY ELUHAD2115 OR EQUAL & FAUCET - AMERICAN STANDARD 4205.000 OR EQUAL 2'-10" REFER TO ELEVATIONS FOR WALL FINISH T-3 2'-0" 4" BACKSPLASH TO MATCH COUNTERTOP 2'-10" 1'-6" 9 2'-10" S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-5_Elevations.dwg, 11/20/2012 5:06:12 PM 2'-5 7/8" 8 FOR BID & PERMIT DATE PLASTIC LAMINATE 4" TOE KICK, MATCH CABINETS PLASTIC LAMINATE 4" TOE KICK, MATCH CABINETS PLASTIC LAMINATE 4" TOE KICK, MATCH CABINETS ISSUE 1'-11 1/4" 8 1'-5 5/8" INTERIOR ELEVATIONS - PANTRY 3 SCALE: 1" = 1'-0" 1'-6" 7 A-5 s t u d i o 1 2 0 0, LLC 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com CERITFICATE OF AUTHORIZATION # AC-710 Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 BUTT JOINT GLASS ALIGN ALIGN TOP OF OPENING W/EXISTING DOOR ALIGN TOP OF OPENING W/EXISTING DOOR 3/8" THICK TEMPERED GLASS 3/8" THICK TEMPERED GLASS 3M GLASS FILM FINE CRYSTAL #SH2FNCR. SUPPLIED AND INSTALLED BY GC ALUMINUM FRAME IN TRIMMED OPENING TO MATCH SIDE LITE DETAIL. SCHEDULED BASE 3M GLASS FILM FINE CRYSTAL #SH2FNCR. APPLY TO CONFERENCE SIDE OF GLASS. TOP AND BOTTOM, ALUMINUM FRAME IN TRIMMED OPENING TO MATCH EXISTING SIDE LITE DETAIL. SCHEDULED BASE *SEE PLAN FOR AREAS LESS THAN 3'-0" V.I.F. INTERIOR ELEVATION - CONFERENCE ROOM A-329 4 INTERIOR ELEVATION - CONFERENCE ROOM A-300 SCALE: 1/2" = 1'-0" 3 INTERIOR ELEVATION - CONFERENCE ROOM A-300 SCALE: 1/2" = 1'-0" 2 3'-0" INTERIOR ELEVATION - SIDE LIGHT ELEVATION TYP. SCALE: 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0" NO 8" VARIES 8" 01 ISSUE FOR BID & PERMIT DATE 11.19.2012 4'-0" WALLTALKER ERASE RITE SEAMLESS HORIZONTAL INSTALLATION, COLOR 05 OFF WHITE. WALLTALKER 1" TACK RAIL TO BE INSTALLED ON 3 SIDES - COLOR ACORN #86 WALLTALKER CLEAR SATIN ANODIZED ALUMINUM TRAY WITH ALUMINUM END CAPS INTERIOR ELEVATION - CONFERENCE ROOM A-330 ENTRANCE 7 SCALE: 1/2" = 1'-0" 2'-8" S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-6_Elevations.dwg, 11/20/2012 5:06:47 PM HOLD 8 " DISTANCE FROM LINE OF SOFFIT OR ADJACENT WALL INTERIOR ELEVATION - WALLTALKER TYPICAL INSTALLATION 6 SCALE: 1/2" = 1'-0" SCALE: 1/2" = 1'-0" BUTT JOINT GLASS 10" 10" INTERIOR ELEVATION - CONFERENCE ROOM C-300 SCALE: 1/2" = 1'-0" 5 INTERIOR ELEVATION - CONFERENCE ROOM A-330 ENTRANCE BUTT JOINT GLASS 3/8" THICK TEMPERED GLASS 3M GLASS FILM FINE CRYSTAL #SH2FNCR. SUPPLIED AND INSTALLED BY GC 3/8" THICK TEMPERED GLASS 3M GLASS FILM FINE CRYSTAL #SH2FNCR. SUPPLIED AND INSTALLED BY GC ALUMINUM FRAME IN TRIMMED OPENING TO MATCH SIDE LITE DETAIL. ALUMINUM FRAME IN TRIMMED OPENING TO MATCH SIDE LITE DETAIL. SCHEDULED BASE SCHEDULED BASE 10" 10 INTERIOR ELEVATION - CONFERENCE ROOM C-300 SCALE: 1/2" = 1'-0" 10" 9 INTERIOR ELEVATIONS 10" INTERIOR ELEVATION - CONFERENCE ROOM C-332 SCALE: 1/2" = 1'-0" ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 8 A-6 2'-0" 2 C-7 s t u d i o 1 2 0 0, LLC 511 MILLBURN AVENUE SHORT HILLS, NJ 07078 973.376.5111 973.376.5011 www.studio1200.com 4 CERITFICATE OF AUTHORIZATION # AC-710 C Nancy Dougherty, AIA, LEED NJ-AI 14861/NY-025099/CT-ARI.0011798 2'-0" 2'-0" P C-6 1 7 7 1 C-7 3 CONFERENCE ROOM A330 - REFLECTED CEILING PLAN SCALE: 1/8" = 1'-0" 3 3 3 2 1'-0" 7 WC-2 WB-8 3 3 1 CONFERENCE ROOM A330 - CONSTRUCTION PLAN - SHOWING FURNITURE & POWER SCALE: 1/8" = 1'-0" NO S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-7_Conference board room.dwg, 11/20/2012 5:07:04 PM 01 ISSUE FOR BID & PERMIT DATE 11.19.2012 KEY NOTES: 1 PROVIDE POWER FOR MOTORIZED WINDOW SHADES AND CONTROL WIRING FROM NEW LIGHTING AND SCENE CONTROL SYSTEM. 2 DEMOLISH ALL SWITCHES AND REPLACE WITH NEW LUTRON SYSTEM TO CONTROL LIGHTS AND WINDOW TREATMENTS. PROVIDE THREE POSITION PRESET FOR SUN SHADE AND TWO POSITION CONTROL FOR BLACK OUT SHADE. LIGHTING TO HAVE 4 PRESET SCENES. 3 EXISTING CREDENZA TO BE REFINISHED TO MATCH EXISTING CONFERENCE ROOM TABLE. REMOVE EXISTING WOOD TOP AND PROVIDE NEW SS-3 COUNTERTOP. 4 LINE OF EXISTING CONFERENCE ROOM TABLE MODIFY EXISTING WINDOW POCKET POCKET AS REQUIRED FOR FLUSH INSTALLATION NEW MECHANICAL SHADING SYSTEM. CONTRACTOR SHALL COORDINATE SEE FINISH PLAN FOR SPECIFICAITON. PROVIDE BLOCKING AS REQUIRED. LINE OF COLUMN BEHIND. NEW TRACK FOR BLACK OUT SHADES INSTALLED AT EACH SIDE OF OPENING ALTERATIONS TO: AVIS BUDGET GROUP THIRD FLOOR 6 SYLVAN WAY PARSIPPANY, NJ 07054 EXISTING RADIATOR TO REMAIN AND REPAINT WITH P-11. CONFERENCE ROOM PLAN, SECTION, AND ELEVATION DETAILS EXTERIOR WALL DETAIL AND MECHANICAL SHADING DEVICE SCALE: 1" = 1'-0" 3 A-7