6 SYLVAN WAY, THIRD FLOOR PARSIPPANY, NEW JERSEY 07054

Transcription

6 SYLVAN WAY, THIRD FLOOR PARSIPPANY, NEW JERSEY 07054
ALTERATIONS TO: AVIS BUDGET GROUP
6 SYLVAN WAY, THIRD FLOOR
PARSIPPANY, NEW JERSEY 07054
BLOCK: 202
LOT: 1.9
OCCUPANCY GROUP: B-BUSINESS
BUILDING IS FULLY SPRINKLERED
THERE IS NO CHANGE TO THE POSTED OCCUPANCY OR EGRESS.
PROJECT DESCRIPTION
THIS ALTERATION PROJECT INCLUDES SELECTIVE DEMOLITION OF NON STRUCTURAL
ELEMENTS, CONSTRUCTION OF INTERIOR PARTITIONS, REMOVAL AND REPLACEMENT OF
ACOUSTIC CEILING TILE, EXISTING GRID TO REMAIN, RELOCATION AND INSTALLATION
OF NEW LIGHTING, AND RENOVATIONS TO THE EXISTING PANTRY AREAS.MECHANICAL,
ELECTRICAL, PLUMBING AND FIRE PROTECTION WORK WILL BE ON A DESIGN BUILD
BASIS.
APPLICABLE CODES:
INTERNATIONAL BUILDING CODE - NJ ED., 2009
NATIONAL ELECTRICAL CODE, 2011
NATIONAL STANDARD PLUMBING CODE, 2009
ASHRAE 90.1-2007
INTERNATIONAL MECHANICAL CODE, 2009
INTERNATIONAL FUEL GAS CODE, 2009
REHABILITATION SUBCODE - NJAC 5:23-6
BARRIER-FREE SUBCODE - NJAC 5:23-7
ANSI A117.1-2003
GENERAL NOTES:
1. COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC
AUTHORITIES GOVERNING THE WORK.
s t u d i o 1 2 0 0, LLC
KEY SITE PLAN
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
LIST OF DRAWINGS:
LEGEND:
NTS
AREA OF WORK
2. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS REQUIRED BY PUBLIC AUTHORITIES
GOVERNING THE WORK.
SHADED AREA NOT IN
SCOPE (EXISTING TO REMAIN)
3. REVIEW DOCUMENTS, VERIFY DIMENSIONS AND FIELD CONDITIONS AND CONFIRM
THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE
ARCHITECT FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION.
4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT &
OWNER FOR REVIEW PRIOR TO PURCHASE, FABRICATION OR INSTALLATION.
5. COORDINATE WORK WITH THE OWNER, INCLUDING SCHEDULING TIME AND
LOCATIONS FOR DELIVERIES, BUILDING ACCESS, USE OF BUILDING SERVICES AND
FACILITIES, AND USE OF ELEVATORS. MINIMIZE DISTURBANCE OF BUILDING FUNCTIONS
AND OCCUPANTS.
6. TENANT WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" UNDER SEPARATE
CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS
SCHEDULE AND COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION
ARCHITECTURAL
CVR
PROJECT DESCRIPTION, GENERAL NOTES, SYMBOLS, & KEY SITE PLAN
A-0
CLEARANCES & GENERAL MOUNTING HEIGHTS
A-1A
CONSTRUCTION/ DEMOLITION PLAN (A) - SHOWING FURNITURE & POWER
A-1B
CONSTRUCTION/ DEMOLITION PLAN (B) - SHOWING FURNITURE & POWER
A-2A
REFLECTED CEILING DEMOLITION PLAN (A)
A-2B
REFLECTED CEILING DEMOLITION PLAN (B)
A-3A
REFLECTED CEILING PLAN (A)
A-3B
REFLECTED CEILING PLAN (B)
A-4A
FINISH PLAN (A)
A-4B
FINISH PLAN (B)
A-5
INTERIOR ELEVATIONS
A-6
INTERIOR ELEVATIONS
A-7
CONFERENCE ROOM PLAN, SECTION, AND ELEVATION DETAILS
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
7. COORDINATE TELECOMMUNICATIONS, DATA AND SECURITY SYSTEM INSTALLATIONS.
8. MAINTAIN EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, AND ALARMS IN
CONFORMANCE WITH CODES AND ORDINANCES.
CHANGE OF USE
NONE.
BASIC REQUIREMENTS
5:23-6.17
(A) TWO EXITS SHALL BE REQUIRED FOR STORIES WITH LESS THAN 500 OCCUPANTS.
(B) A MINIMUM OF TWO EGRESS DOORWAYS SHALL BE REQUIRED FOR ROOMS AND SPACES WITH AN
OCCUPANT LOAD GREATER THAN 50. ALL EGRESS DOORS SERVING AN OCCUPANT LOAD GREATER
THAN 50 SHALL SWING IN THE DIRECTION OF TRAVEL.
(C) THE CAPACITY OF THE MEANS OF EGRESS IN EACH WORK AREA SHALL BE DETERMINED IN
ACCORDANCE WITH NJAC 5:23-6.11(B).
(D) 2. DEAD END CORRIDORS MAY BE UP TO 70 FEET IN LENGTH IN A BUILDING WITH AN AUTOMATIC
SPRINKLER SYSTEM INSTALLED.
(E) MEANS OF EGRESS LIGHTING: ARTIFICIAL LIGHTING WITH AN INTENSITY OF NOT LESS THAN ONE
FOOT CANDLE AT FLOOR LEVEL SHALL BE REQUIRED DURING ALL TIMES THAT THE CONDITIONS OF
OCCUPANCY OF THE BUILDING REQUIRE THAT THE EXITS BE AVAILABLE.
(F) ILLUMINATED EXIT SIGNS SHALL BE PROVIDED FOR ALL REQUIRED MEANS OF EGRESS IN ALL
BUILDINGS, ROOMS OR SPACES REQUIRED TO HAVE MORE THAN ONE EXIT.
(J) STRUCTURAL ELEMENTS: STRUCTURAL ELEMENTS WHICH ARE UNCOVERED DURING THE
COURSE OF THE REHABILITATION AND WHICH ARE FOUND TO BE UNSOUND OR OTHERWISE
STRUCTURALLY DEFICIENT, SHALL BE REINFORCED, SUPPORTED OR REPLACED IN ACCORDANCE
WITH THE APPLICABLE STRUCTURAL DESIGN CRITERIA OF THE BUILDING SUBCODE. WHERE
STRUCTURAL ELEMENTS ARE SOUND, THERE IS NO EXCESSIVE DEFLECTION, AND FIXED LOADS ARE
NOT CHANGING IN A WAY THAT WILL INCREASE THE STRESSES ON EXISTING STRUCTURES BEYOND
THAT WHICH IS PERMITTED BY N.J.A.C. 5:23-6.7(C), EXISTING STRUCTURAL ELEMENTS SHALL BE
PERMITTED TO REMAIN.
(M) INTERIOR FINISHES SHALL COMPLY WITH N.J.A.C. 5:23-6.11(C).
(O) FIREBLOCKING AND DRAFTSTOPPING: WHEN THE WORK BEING PERFORMED CREATES OR
EXPOSES THE FRAMING OF ANY WALL, FLOOR, CEILING, OR ROOF, THE FRAMING SHALL COMPLY
WITH SECTION 717 OF THE BUILDING SUBCODE.
ALTERATION NOTES:
ALL WORK SHALL COMPLY WITH NJUCC 5:23-6.6 ALTERATIONS. IN PARTICULAR, THE WORK SHALL
MEET THE FOLLOWING:
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\CVR.dwg, 11/20/2012 5:04:05 PM
6.6 (C) 2. EXISTING FIRE ALARM, AUTOMATIC SPRINKLER, STANDPIPE, SMOKE CONTROL AND
EMERGENCY POWER SYSTEMS SHALL NOT BE REMOVED WITHOUT REPLACEMENT AND SHALL BE
MAINTAINED IN OPERATING CONDITION.
6.6 (C) 3. NO WORK SHALL BE UNDERTAKEN THAT DIMINISHES ACCESSIBILITY BELOW THAT WHICH IS
REQUIRED BY THE BARRIER FREE SUBCODE OF THE UNIFORM CONSTRUCTION CODE, N.J.A.C. 5:23-7.
6.6 (C) 4. CONSTRUCTION MATERIALS USED AS PART OF AN ALTERATION PROJECT SHALL BE
CONSISTENT WITH THE EXISTING CONSTRUCTION TYPE OR THE ALLOWABLE CONSTRUCTION TYPE,
WHICHEVER IS LESS RESTRICTIVE.
6.6 (E) 1. WHEN ANY WATER CLOSET IS REPLACED, THE REPLACEMENT WATER CLOSET SHALL
REQUIRE NOT MORE THAN 1.6 GALLONS OF WATER PER FLUSH AS REQUIRED BY THE PLUMBING
SUBCODE.
6.6 (E) 2. IN BUILDINGS REQUIRED BY THE BARRIER FREE SUBCODE TO BE ACCESSIBLE, WHEN
BATHROOMS OR TOILET ROOMS ARE ALTERED, THE FOLLOWING REQUIREMENTS PROVIDING
ACCESSIBILITY SHALL APPLY UNLESS THE REQUIREMENTS OF THE BARRIER FREE SUBCODE HAVE
BEEN MET:
6.6 (E) 2.ii. WHEN BATHROOM FIXTURES OR HARDWARE ARE REPLACED, THE REPLACEMENT
FIXTURES OR HARDWARE SHALL COMPLY WITH ICC/ANSI A117.1-2003, SECTIONS 603 THROUGH 608.
6.6 (E) 2.iii. WHEN SPACE IS RECONFIGURED, THE ALTERED SPACE SHALL COMPLY WITH THE BARRIER
FREE SUBCODE, N.J.A.C. 5:23-7.
6.6 (E) 3.i. WHEN NEW DOOR OPENINGS ARE CREATED OR DOOR ASSEMBLIES ARE REPLACED AND
THE REQUIRED DOOR WIDTH CAN BE ACHIEVED WITHIN THE EXISTING OPENING, THE NEW DOOR
SHALL COMPLY WITH ICC/ ANSI A117.1-2003, SECTION 404.
6.6 (E) 6. REPLACEMENT GLASS SHALL COMPLY WITH THE "SAFETY GLAZING" REQUIREMENTS OF THE
BUILDING SUBCODE AND SHALL BE INSTALLED IN THE "SPECIFIC HAZARDOUS LOCATIONS" AS
SPECIFIED BY SECTION 2406.3 OF THE BUILDING SUBCODE.
6.6 (E) 7. WHERE A FIREPROOFING MATERIAL IS REMOVED THAT IS INTEGRAL TO THE RATING OF AN
EXISTING FIRE-RATED ASSEMBLY, THE MATERIAL SHALL BE REPLACED SO THAT THE RATING IS
PRESERVED.
6.6 (E) 14. WHEN THE WORK BEING PERFORMED CREATES OR EXPOSES WOOD FRAMING OF ANY
WALL, FLOOR, CEILING, OR ROOF, FIRE-BLOCKING SHALL BE PROVIDED AS REQUIRED BY SECTION
717.2 OF THE BUILDING SUBCODE.
6.6 (E) 15. WHEN THE WORK BEING PERFORMED CREATES OR EXPOSES THE ENTIRE FRAMING OF
ANY WALL, FLOOR, CEILING, OR ROOF ASSEMBLY THAT IS PART OF THE BUILDING THERMAL
ENVELOPE (ENCLOSES CONDITIONED SPACE) AND THERE IS NO INSULATION IN THE CAVITIES,
INSULATION MEETING A MINIMUM R-VALUE SHALL BE INSTALLED THAT FILLS THE CAVITIES OF THE
FRAMED ASSEMBLY.
9. PROTECT AREA OF WORK AND ADJACENT AREAS FROM DAMAGE.
10. MAINTAIN WORK AREAS SECURE AND LOCKABLE DURING CONSTRUCTION.
COORDINATE WITH TENANT AND LANDLORD TO ENSURE SECURITY.
11. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OF CONFLICT,
CONSULT THE ARCHITECT.
MAIN
ENTRANCE
12. PARTITIONS ARE DIMENSIONED FROM FINISH FACE TO FINISH FACE, UNLESS
OTHERWISE NOTED. MAINTAIN DIMENSIONS MARKED "CLEAR". ALLOW FOR THICKNESS
OF FINISHES.
13. COORDINATE AND PROVIDE BLOCKING FOR MILLWORK AND ITEMS ATTACHED OR
MOUNTED TO WALLS OR CEILINGS.
14. WHERE EXISTING ACCESS PANELS CONFLICT WITH CONSTRUCTION, RELOCATE
PANELS TO ALIGN WITH AND FIT WITHIN NEW CONSTRUCTION.
15. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHES BY 1/4 INCH, UNLESS
OTHERWISE NOTED.
N
FIRE DEPARTMENT NOTES:
1. PROVIDE FIRE EXTINGUISHER CABINETS OR MOUNTING BRACKETS WHERE SHOWN ON
DRAWINGS WITHIN 75 FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON
EACH FLOOR, AND ADDITIONAL LOCATIONS AS REQUIRED BY FIRE DEPARTMENT FIELD
INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. PORTABLE EXTINGUISHERS ARE TO
BE PROVIDED BY TENANT OR LANDLORD AND HAVE A RATING NOT LESS THAN 2A.
2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON
DRAWINGS, AND ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT
INSPECTOR OR FIRE DEPARTMENT FIELD INSPECTOR. CONNECT EXIT SIGNS TO
EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES.
3. PROVIDE EMERGENCY LIGHTING PER ELECTRICAL DRAWINGS OF ONE FOOT-CANDLE
AT FLOOR LEVEL. COMPLY WITH BUILDING CODES.
4. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY
OR ANY SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN
APPROVED TYPE. ALL NEW DOORS SHALL HAVE APPROVED LEVER HANDLES.
5. DOORS OPENING INTO REQUIRED 1-HOUR, FIRE-RESISTIVE CORRIDORS SHALL BE
PROTECTED WITH A SMOKE OR DRAFT STOP ASSEMBLY HAVING A 20-MINUTE RATING
AND SHALL BE SELF-CLOSING.
6. EXIT DOORS SHALL SWING IN THE DIRECTION OF TRAVEL WHEN SERVING 50 OR MORE
PERSONS AND IN ANY HAZARDOUS AREA.
7. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDOR SHALL NOT EXCEED AN
END POINT FLAME SPREAD RATING: A. CLASS I, FLAME SPREAD 0-25, SMOKE DENSITY
150, FOR MATERIALS INSTALLED IN VERTICAL EXITS. B. CLASS II, FLAME SPREAD 26-75,
SMOKE DENSITY 300, FOR MATERIALS INSTALLED IN HORIZONTAL EXITS. C. CLASS III,
FLAME SPREAD 76-200, SMOKE DENSITY 450, FOR MATERIALS INSTALLED IN ANY OTHER
LOCATION.
8. DECORATIONS (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) SHALL BE
NON-COMBUSTIBLE OR BE FLAMEPROOFED IN AN APPROVED MANNER.
9. PROVIDE FIRE DAMPERS OR DOORS WHERE AIR DUCTS PENETRATE FIRE-RATED WALLS
OR CEILINGS.
10. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS,
FLAMMABLE GAS AND HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE
CODE REGULATIONS.
11. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE
CODE REQUIREMENTS.
12. EXTEND OR MODIFY EXISTING FIRE/LIFE SAFETY SYSTEM AS REQUIRED TO PROVIDE AN
APPROVED FIRE/ LIFE SAFETY SYSTEM. SUBMIT PLANS TO FIRE DEPARTMENT WITH
COMPLETE DESCRIPTION OF SEQUENCE OF OPERATION, AND OBTAIN APPROVAL
PRIOR TO INSTALLATION.
13. LOCATE THE CENTER OF FIRE ALARM INITIATING DEVICES 48" ABOVE THE LEVEL OF
THE FLOOR, WORKING PLATFORM, GROUND SURFACE OR SIDEWALK.
14. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE
HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT
MORE THAN 60 FLASHES PER MINUTE. ALL STROBES TO FLASH SIMULTANEOUSLY AS
REQUIRED BY CODE.
15. EXTEND OR MODIFY EXISTING AUTOMATIC FIRE EXTINGUISHING SYSTEM AS
REQUIRED TO PROVIDE AN APPROVED AUTOMATIC FIRE EXTINGUISHING SYSTEM.
SUBMIT PLANS TO FIRE DEPARTMENT AND OBTAIN APPROVAL PRIOR TO INSTALLATION.
16. AUTOMATIC SPRINKLER SYSTEMS SHALL BE SUPERVISED BY AN APPROVED CENTRAL,
PROPRIETARY OR REMOTE STATION SERVICE OR A LOCAL ALARM WHICH WILL GIVE AN
AUDIBLE SIGNAL AT A CONSTANTLY ATTENDED LOCATION.
SELECTIVE DEMOLITION NOTES:
1. COMPLY WITH APPLICABLE LOCAL, STATE AND FEDERAL CODES AND REGULATIONS
PERTAINING TO SAFETY OF PERSONS, PROPERTY AND ENVIRONMENTAL PROTECTION.
2. PROVIDE AND MAINTAIN BARRICADES, LIGHTING, AND GUARDRAILS AS REQUIRED BY
APPLICABLE CODES AND REGULATIONS TO PROTECT OCCUPANTS OF BUILDING AND
WORKERS.
3. ERECT AND MAINTAIN DUSTPROOF PARTITIONS AS REQUIRED TO PREVENT SPREAD
OF DUST, FUMES, AND SMOKE, ETC. TO OTHER PARTS OF THE BUILDING. ON
COMPLETION, REMOVE PARTITIONS AND REPAIR DAMAGED SURFACES TO MATCH
ADJACENT SURFACES.
4. IF DEMOLITION IS PERFORMED IN EXCESS OF THAT REQUIRED, RESTORE AFFECTED
AREAS AT NO COST TO THE OWNER.
5. REMOVE FROM SITE DAILY AND LEGALLY DISPOSE OF REFUSE, DEBRIS, RUBBISH, AND
OTHER MATERIALS RESULTING FROM DEMOLITION OPERATIONS.
6. REMOVE DESIGNATED PARTITIONS, COMPONENTS, BUILDING EQUIPMENT, AND
FIXTURES AS REQUIRED FOR NEW WORK.
7. REMOVE ABANDONED HVAC EQUIPMENT, INCLUDING DUCT WORK.
8. REMOVE ABANDONED ELECTRICAL, TELEPHONE AND DATA CABLING AND DEVICES,
UNLESS OTHERWISE NOTED.
9. REMOVE EXISTING FLOOR FINISHES WHERE INDICATED AND PREPARE SUBFLOOR AS
REQUIRED FOR NEW FLOOR FINISHES.
REFLECTED CEILING NOTES:
1. WHERE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE
PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING
METHODS MAY BE EMPLOYED: A. PROVIDE LATERAL SUPPORT BY FOUR WIRES OF
MINIMUM NO. 12 GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND
CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE
STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF
THE CEILING. PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH
DIRECTION, WITH THE FIRST POINT WITHIN 4' FROM EACH WALL. B. ALLOW FOR LATERAL
MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT TWO
ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT
THE OTHER TWO WALLS. C. PROVIDE VERTICAL SUPPORT AS REQUIRED IN BUILDING
CODES. IN ADDITION, VERTICALLY SUPPORT ENDS OF RUNNERS WITHIN 8" OF
DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING IS INTERRUPTED BY A WALL.
D. SUPPORT LIGHT FIXTURES AND AIR DIFFUSERS DIRECTLY BY WIRES TO THE STRUCTURE
ABOVE.
2. LOCATE REGISTERS AND LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPRINKLER
HEADS, SPEAKERS, RECESSED FIXTURES, AND SIMILAR CEILING ELEMENTS IN
ACOUSTICAL UNITS, UNLESS OTHERWISE NOTED.
3. FINISH HVAC DIFFUSERS, DRAPERY POCKETS, AND SPEAKER GRILLES TO MATCH
ADJACENT FINISH, UNLESS OTHERWISE NOTED.
POWER & COMMUNICATIONS NOTES:
1. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA AND SECURITY
SYSTEMS.
2. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH
MANUFACTURER TO ENSURE PROPER FIT AND FUNCTION.
3. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE AND OTHER
EQUIPMENT.
NO
SYMBOLS:
6. MOUNT STANDARD WALL OUTLETS, SWITCHES AND THERMOSTATS AT HEIGHTS
REQUIRED BY ACCESSIBILITY GUIDELINES, UNLESS OTHERWISE NOTED. WHEN
THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER, INSTALL BOTH ALIGNED
HORIZONTALLY WITH CENTER LINE AT +3'-2" ABOVE FINISHED FLOOR.
A
WALL TYPE
SECTION MARK
DOOR TAG
DETAIL TAG
SECTION NO.
DWG. NO.
1
A-2
DOOR NO.
101
DETAIL NO.
DWG. NO.
1
A-2
CEILING PAINT COLOR
P-1
ELEVATION
SECTION NO.
DWG. NO.
PARTITIONS
EXISTING (UNSHADED)
NEW (SHADED)
8. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO
NOT INSTALL BACK-TO-BACK.
9. PROVIDE MATCHING COVER PLATES, RECEPTACLES AND RELATED ITEMS. PROVIDE
ONE-PIECE TYPE GANG COVER PLATES, UNLESS OTHERWISE NOTED.
1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, AND FREE OF
IRREGULARITIES. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS
HAVE BEEN CORRECTED.
2. REPAIR EXISTING SURFACES TO REMAIN AS REQUIRED FOR APPLICATION OF NEW
FINISHES.
HVAC NOTES:
1. THE EXISTING HVAC SHALL REMAIN AND BE RE-WORKED IF NECESSARY AS A RESULT
OF THIS WORK. THIS INCLUDES RELOCATING DIFFUSERS, RETURN GRILLES, ETC.
SPRINKLER NOTES:
100
KEY NOTE TAG
X
EQUIPMENT AND
MILLWORK TAG
WALL FINISH
BASE FINISH
X
X
FINISH TAG
WALL FINISH
WALL FINISH
BASE FINISH
X
X
X
FLOOR FINISH
ABBREVIATIONS:
SPRINKLER HEAD
GYPSUM WALL BOARD
GYPSUM
HANDICAP
HOLLOW METAL
MAXIMUM
MINIMUM
MASONRY OPENING
METAL
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOT TO SCALE
ON CENTER
OUTSIDE DIAMETER
REQUIRED
SPECIFICATIONS
STEEL
STRUCTURAL
TOP OF
TYPICAL
UNLESS OTHERWISE NOTED
VINYL COMPOSITION TILE
VERIFY IN FIELD
XXX
FINISH TAG
DOOR PAINT
GWB.
GYP.
HC
HM
MAX.
MIN.
M.O.
MTL
N/A
N.I.C.
NO.
NTS
O.C.
O.D.
REQ.
SPECS.
STL
STRUCT.
T.O.
TYP.
U.O.N.
VCT
V.I.F.
1
A-2
ROOM NUMBER
1. THE EXISTING SPRINKLER SYSTEM SHALL REMAIN AND BE RE-WORKED IF NECESSARY AS
A RESULT OF THIS WORK. THIS INCLUDES RELOCATING SPRINKLER HEADS.
A.F.F.
ABOVE FINISHED FLOOR
ALIGN ALIGNMENT
ALUM. ALUMINUM
BD.
BOARD
BLDG
BUILDING
B.O.
BOTTOM OF
C.J.
CONTROL JOINT
CLG
CEILING
C.M.U. CONC. MASONRY UNIT
COL.
COLUMN
CONC. CONCRETE
CONT. CONTINUOUS
DEMO. DEMOLISH
DET.
DETAIL
DIA.
DIAMETER
DN.
DOWN
DWG.
DRAWING
EL. / ELEV.
ELEVATION
EQ.
EQUAL
F.E.
FIRE EXTINGUISHER
F.F.
FINISHED FLOOR
FLR.
FLOOR
FURN.
FURNITURE
GALV. GALVANIZED
11.19.2012
LEVEL LINE, START POINT
OR DATUM
7. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR
CLUSTER OF OUTLETS OR SWITCHES, UNLESS OTHERWISE NOTED.
FINISH NOTES:
FOR BID & PERMIT
DATE
NTS
4. GANG ADJACENT LIGHT SWITCHES AND COVER WITH A SINGLE PLATE.
5. PROVIDE LIGHT SWITCHING IN CONFORMANCE WITH ACCESSIBILITY REQUIREMENTS.
01
ISSUE
XXX
DOOR FINISH
FRAME FINISH
SUPPLY DIFFUSER ANEMOSTAT
PLATEAU TYPE U.O.N.
EXHAUST
FIRE STROBE
FS
FIRE SPEAKER STROBE
FSS
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
MOTION SENSOR
EXISTING DOOR
NEW DOOR
PROJECT DESCRIPTION,
GENERAL NOTES, SYMBOLS
& KEY SITE PLAN
DUPLEX OUTLET
CVR
1/4" - 1/2"
CHANGES IN LEVEL
(A) FRONT APPROACH, PULL SIDE
UNOBSTRUCTED HIGH SIDE REACH
CLEAR WIDTH OF DOORWAY
2
MOUNTING HEIGHTS
32" min
DOOR FRAME
1
COAT HOOK
60 " MIN
ADA COAT HOOK
12"
THERMOSTAT, INTERCOM OR 2ND ROW
OF RECEPTACLES CENTER TO CLUSTER
18" MIN
LIGHT SWITCH, DIMMERS, EGRESS
BUTTON, INTERCOM BUTTON,
CARD READER, ETC. CLUSTER,
(SEE PLAN FOR QUANTITY OF
EACH CLUSTER)
80"
DOORWAYS WITHOUT DOORS
CLEAR FLOOR
SPACE
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
30" MIN
NOTE: X = 12" MIN. IF BOTH
CLOSER AND LATCH ARE
PROVIDED.
36" MIN
A.F.F.
X
38"
X
48"
10" MAX
NOTE: X = 10" MAX IF
Y = 48" MAX.
X = >10" - 24" MAX IF
Y = 46" MAX
48" MIN
48" MIN
66"
CLEAR FLOOR AREA
46"
SCALE: NTS
34" MAX
1
THRESHOLDS
Y
1/4"
MAX
FIRE ALARM DEVICE
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
DOOR LEVER, PULL
POWER AND TELEPHONE RECEPTACLE
DOOR
OR OPENING
> 24"
36" MIN
s t u d i o 1 2 0 0, LLC
FINISH FLOOR
EDGE OF DOOR OR
SIDELIGHT PANEL
TYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS,
EGRESS BUTTONS, THERMOSTATS, ETC.
CERITFICATE OF AUTHORIZATION # AC-710
10" MAX
32" MIN
(B) FRONT APPROACH, PUSH SIDE
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
COAT HOOK
17" - 25"
24" MAX
FIRE ALARM DEVICE
(C&D) HINGE APPROACH, PULL SIDE
DOOR FRAME
12"
2 DOORS IN A SERIES
NOTE: X = 36" MIN. IF Y = 60" MIN.
X = 42" MIN. IF Y = 54" MIN.
KNEE & TOE CLEARANCE
THERMOSTAT, INTERCOM OR 2ND ROW
OF RECEPTACLES CENTER TO CLUSTER
MIRROR
LIGHT SWITCH, DIMMERS, EGRESS
BUTTON, INTERCOM BUTTON,
CARD READER, ETC. CLUSTER,
(SEE PLAN FOR QUANTITY OF
EACH CLUSTER)
80"
38"
46"
DOOR LEVER, PULL
POWER AND TELEPHONE RECEPTACLE
24" MAX
3'-4" MAX
DOOR
OR OPENING
60" MIN
2'-10" MAX
2'-5" MIN
2'-3" MIN
9" MIN
X
A.F.F.
66"
LINE OF
REQUIRED
CLEARANCE.
Y
48" MIN
INSULATE HOT WATER PIPES
AND DRAIN TO PREVENT
CONTACT.
(E) HINGE APPROACH, PUSH SIDE
32" MIN
MAX KNEE CLEARANCE 8" MIN 6" MAX TOE CLEARANCE
NOTE: X = 12" MIN. IF BOTH CLOSER
AND LATCH ARE PROVIDED.
Y = 42" MIN.
Y = 48" MIN IF BOTH CLOSER AND
LATCH ARE PROVIDED.
Y
36" MIN
1'-5" MIN DEPTH
X
FINISH FLOOR
TYPICAL LOCATION FOR TWO ROWS OF LIGHT SWITCHES,
DIMMERS, EGRESS BUTTONS, THERMOSTATS, ETC.
EDGE OF DOOR OR
SIDELIGHT PANEL
60" MIN
22" MIN
TYPICAL WALL
PANEL JOINT
2
SINK OR VANITY
SCALE: 1/2" = 1'-0"
UNOBSTRUCTED FORWARD REACH
CLEAR WIDTH AT TURN
NOTE:
X = 36" MIN IF Y = 60" MIN.
X = 42" MIN IF Y = 48" MIN.
EQ.
EQ.
EQ.
POWER AND TELEPHONE
RECEPTACLE &
CLUSTER HORIZONTALLY
MOUNTED,
CENTERED BETWEEN
PANEL JOINT
EQ.
Y
48" MAX
6"
2 DOORS IN A SERIES
15"
15" MIN
(F) LATCH APPROACH, PULL SIDE
FINISH FLOOR
Y
DOOR WIDTH
NOTE:
Y = 48" MIN.
Y = 54" MIN IF CLOSER IS
PROVIDED.
TYPICAL LOCATION FOR POWER AND TELEPHONE
OUTLETS AT WALL PANEL OR COLUMN
NO
01
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
24" MIN
UNOBSTRUCTED HIGH FORWARD REACH
48" MIN
NOTE: X = >20 - 25"
IF Y = 44" MAX.
X = 20" MAX IF
Y = 48" MAX
(G) LATCH APPROACH, PUSH SIDE
6"
SO HANDLE OF
EXTINGUISHER
IS 48" AFF
ELEC DATA
15"
Y
GRAB BAR AND ACCESSORIES
DOOR WIDTH
Y
NOTE:
Y = 42" MIN.
Y = 48" MIN IF CLOSER IS
PROVIDED.
BACKBOX
SIZES TO BE
CONFIRMED &
COORDINATED
WITH DATA/TEL
VENDOR.
48"
X
X < 48
FINISH FLOOR
24" MIN
X
TYPICAL LOCATION FOR FIRE
EXTINGUISHER/FIRE EXTINGUISHER
CABINET.
TYPICAL LOCATION FOR COMBINED
OUTLETS AT VISIBLE AREAS
3
REACH RANGES
SCALE: 1/2" = 1'-0"
36" MIN
LIMITS OF PROTRUDING OBJECTS
4" max
18" MIN
12" MIN
EQ.
12"
16"-18"
EQ.
WALL HUNG
TELEPHONE
24" MIN
4" MAX.
48"
48"
EDGE OF DOOR OR
SIDELIGHT PANEL
DOOR
OR OPENING
15"
15"
60" MIN
60" MIN.
31" MIN.
TYPICAL LOCATION FOR WALL HUNG TELEPHONE
AT WALL OR COLUMN
DOOR WIDTH
28" MIN
WALL OUTLET
48" MIN
60" MIN.
17"-19"
15" MIN
33"-36"
39"-41"
WHEELCHAIR ACCESSIBLE STALL
80" MIN
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
60" MIN
UNOBSTRUCTED SIDE REACH
4" MAX.
54" MIN
42" MIN
EQ.
12"
39"-41"
AMBULATORY ACCESSIBLE STALL
12" MAX
EQ.
RECESSED
PULLSTATION
SCALE: 1/2" = 1'-0"
80"
36" MIN.
CLEARANCES &
GENERAL MOUNTING
HEIGHTS
SCALE: 1/2" = 1'-0"
39"-41"
48"
CLEARANCES
33"-36"
15" MIN
4
7"-9"
17"-19"
CL
10"
MAX
CLEARANCES
24" MIN.*
48" MAX
18" MIN
60" MIN.
15" MIN
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-0_Clearances.dwg, 11/20/2012 5:04:11 PM
X
FIRE
EXTINGUISHER
CABINET
DOOR
OR OPENING
* AT AMBULATORY STALLS ONLY
EDGE OF DOOR OR
SIDELIGHT PANEL
TYPICAL LOCATION FOR SINGLE WALL MOUNTED
FIRE ALARM DEVICE /PULL STATION AT WALL OR COLUMN
5
CLEARANCES
SCALE: 1/2" = 1'-0"
6
CLEARANCES
SCALE: 1/2" = 1'-0"
7
GENERAL MOUNTING HEIGHTS
SCALE: 1/2" = 1'-0"
8
A-0
GENERAL NOTES:
B307
B308
B309
B310
B311
B312
B313
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ELECTRICAL SYMBOLS
SYM.
TYPE
3
WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED. NUMBER REPRESENTS
AMOUNT OF RECEPTICLES AT SYSTEM FURNITURE
DEDICATED WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED
1.
CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING WORK OF ALL CONSULTANTS AND
SUBCONTRACTORS, WHETHER HIRED BY THE OWNER
OR BY CONTRACTOR.
2.
CONTRACTOR IS RESPONSIBLE FOR ALL WORK
IDENTIFIED ON ALL DRAWINGS UNLESS OTHERWISE
NOTED.
3.
SHADED AREA ON PLAN INDICATES AREAS OUTSIDE
SCOPE OF WORK (NIC).
4.
REFER TO PLAN FOR ALL ELEVATION TAGS.
5.
ALL NEW INTERIOR FRAMING SHALL MATCH EXISTING
2X CONSTRUCTION OF ADJACENT WALLS U.O.N.
AND ARE SHOWN SHADED ON PLAN.
6.
DIMENSIONS SHOWN ARE MEASURED FROM FACE
OF FINISH WALL.
WALL MTD. QUAD RECEPTACLE, "R" DENOTES RELOCATED
1
GFCI
EQ-4
EQ-4
WALL MTD. GFCI DUPLEX RECEPTACLE
WALL MTD. "POWER INFEED" FOR VOICE/ DATA CONNECTIONS TO MODULAR
FURNITURE. COORDINATE W/ FURNITURE VENDOR. "R" AND "N" DENOTE
RELOCATED AND NEW. "E" DENOTES EXISTING.
B306
FLOOR MTD. "POWER INFEED" FOR VOICE/ DATA AND ELECTRICAL
CONNECTIONS TO MODULAR FURNITURE. CUT AND PATCH SLAB ACCORDINGLY
FOR FEED AND CONDUIT. RELOCATE EXISTING POWER IN-FEED AS INDICATED ON
PLAN FOR NEW FURNITURE LAYOUT. COORDINATE EXACT LOCATION WITH
FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW, "E" DENOTES
EXISTING.
4 3
4 3
4 3
ADMIN.
4 3
OFFICE
7.
CONTRACTOR SHALL PROVIDE FIRE RETARDANT
BLOCKING IN WALLS AS REQUIRED FOR MILLWORK,
LCD TV'S, ETC.
8.
THE ENTIRE AREA IN SCOPE SHALL BE THOROUGHLY
CLEANED, INCLUDING WAXING & POLISHING AT THE
COMPLETION OF CONSTRUCTION.
3
4 3
4 3
4 3
ADMIN.
WALL MTD. VOICE RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME
RUNS
2
EQ-1
EQ-10
OFFICE
4 3
13
4 3
B305
4 3
4 3
12 13
4
WALL MTD. COMBINATION VOICE/DATA RECEPTACLE, NUMBER REPRESENTS
AMOUNT OF CAT5 HOME RUNS
1
WALL MTD. CABLE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5
HOME RUNS
B304
OFFICE
EQ-24 EQ-27
2
EQ-26 EQ-28
A-5
EQ-29
6
4 3
10. REFER TO REFLECTED CEILING PLAN ON A-3A & A-3B
FOR NEW LIGHTING SPECIFICATION.
WALL MTD. CABLE T.V. CONNECTION
11. SEE EQUIPMENT SCHEDULE & ELECTRICAL SYMBOLS
THIS SHEET FOR MORE INFORMATION.
RECESSED FLOOR BOX , FSR 500P-S-C - 3" DEEP, CONFIRM WITH TENANT
COMPONENTS WITH
12. ALL NEW OUTLETS SHALL BE MTD. @ 18" A.F.F. U.O.N.
CR
CARD READER
EB
EGRESS OVERRIDE BUTTON
IR
INFRARED OVERHEAD RELEASE
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
14. DIMENSIONS AT FURNITURE LOCATIONS TO BE
COORDINATED AND CONFIRMED WITH FURNITURE
VENDOR, FURNITURE VENDOR WILL BE MARKING
OUT LOCATIONS OF FLOOR BOXES AND PANELS
EXISTING DATA AND DUPLEX TO REMAIN
E
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
13. CONTRACTOR SHALL BE RESPONSIBLE FOR
REMOVING ALL EXISTING CARPET, TILE, AND BASE IN
AREAS OF WORK. CONTRACTOR SHALL PREPARE
ALL SURFACES AS REQUIRED TO RECEIVE NEW
FINISHES.
B303
OFFICE
REFER TO FINISH PLAN ON A-4A & A-4B FOR ALL NEW
FINISHES.
9.
s t u d i o 1 2 0 0, LLC
15. EXISTING POWER AND DATA AT OFFICES TO REMAIN
U.O.N.
4 3
B302
OFFICE
PHASE III
16. GC SHALL REMOVE AND DISCARD ALL EXISTING 1X2
ACCENT WOOD TRIM BAND CURRENTLY INSTALLED
BETWEEN DOOR AT VARIOUS LOCATIONS
THROUGHOUT OPEN OFFICE AREAS.
4 3
EQUIPMENT SCHEDULE
B301
SYM.
DESCRIPTION
MANUFACTURER
MODEL NUMBER
NOTES
OFFICE
4 3
EQ-1
B300
EQ-2
MULTI FUNCTION PRINTER/COPIER
BY TENANT
PAPER SHREDDER BIN
CANON
-
5055
-
A307
A306
A305
A304
A303
A302
A301
A300
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
13
INSTALLED BY
CONTRACTOR. SPECIAL
PLUG - NEMA 5-20R
17. PROVIDE 3'-0" WIDE TRIMMED OPENING AND SIDE
LITE TO MATCH EXISTING (ALUMINUM EXTRUDED
GLASS CHANNEL WITH REMOVABLE STOP) TO ALL
PERIMETER OFFICES U.O.N. SEE DETAIL # 1 ON A-6.
TO BE RELOCATED
18. CONTRACTOR TO MODIFY OR RELOCATE EXISTING
POWER AND DATA INFEED AS REQUIRED BY NEW
FURNITURE.
19. CONTRACTOR TO RELOCATE ALL SWITCHES AS
REQUIRED DUE TO INSTALLATION OF NEW
SIDELIGHTS.
(FLOOR STANDING)
OFFICE
A308
EXISTING
NOTES
EQ-3
LASER JET DESKTOP PRINTER
HP
4015
TO BE RELOCATED, AS
SHOWN
EQ-4
LASER JET DESKTOP PRINTER
HP
4250
TO BE RELOCATED, AS
SHOWN
EQ-5
LASER PRINTER/COPIER BY TENANT
CANON
2050
EQ-30
3
5
16
A-6
1
2
A-6
A-6
4
EQ-6
POWER SHRED
FELLOWS
C-120
4
EQ-7
FAX
PITNEY BOWES
1630
1
OFFICE
4 3
4 3
4 3
4 3
13'-0"
A327
A328
OFFICE
OFFICE
4
4 3
23'-2"
A310
7
A343
HP
TO BE RELOCATED, AS
SHOWN
H
TO BE RELOCATED, AS
SHOWN
NJ2AVXTECPRT11
EQ-9
FAX
TOSHIBA
-
TO BE RELOCATED, AS
SHOWN
EQ-10
MULTI FUNCTION PRINTER/COPIER
BY TENANT
CANON
5185
PLUG - NEMA 5-20R TO BE
PROVIDED BY
CONTRACTOR
EQ-11
ENERGY STAR MINI FRIDGE
-
-
REMOVED FROM THE PLAN
EQ-12
LASER JET DESKTOP PRINTER
HP
9050
TO BE RELOCATED, AS
SHOWN
EQ-13
LASER PRINTER/COPIER BY TENANT
IKON CANON
CLASS -810
TO BE RELOCATED, AS
SHOWN
EQ-27
4 3
1
EQ-29
2
A-5
DESKTOP FAX
BROTHER
INTELLIFAX
OFFICE
A325
4
14
EQ-15
NOT USED
-
-
EQ-16
LASER JET DESKTOP PRINTER
HP
P4015N
EQ-17
LASER JET DESKTOP PRINTER
HP
P4650N
EQ-18
MULTI FUNCTION PRINTER/COPIER
BY TENANT
TOSHIBA
STUDIO 170F
EQ-19
LASER FAX
CANON
CLASS-730I
EQ-20
MULTI FUNCTION PRINTER/COPIER
BY TENANT
CANON
CLASS-730I
EQ-21
MULTI FUNCTION PRINTER/COPIER
BY TENANT
GENICOM
5000
EQ-22
FAX
LEXMARK
AVFLTLAZERO6
EQ-23
LOCKABLE CABINET
-
-
-
OFFICE
CONF. RM.
CONF. RM.
H
TO BE RELOCATED, AS
SHOWN
3
OFFICE
4 3
4 3
4 3
4 3
ADMIN.
3
REMOVE EXISTING POWER AND DATA INFEED AT
FLOOR OR WALL, SAFE OFF AND PATCH AS
REQUIRED
4
REMOVE DOOR, FRAME, & HARDWARE. INFILL
WALL SECTION TO MATCH EXISTING ADJACENT
WALL AS REQUIRED. PROVIDE NEW SIDELIGHT IN
INDICATED LOCATIONS.
5
CORE FLOOR FOR NEW TABLE TOP POWER &
DATA AT CONFERENCE TABLE. PROVIDE SEPARATE
CORES, ONE 3 4" FOR DUPLEX OUTLET & ONE 2"
FOR AV &DATA BELOW THE TABLE. AN
ADDITIONAL 2" CORE IN AN ADJACENT WALL TO
RUN CABLE FROM TABLE TOP TO CEILING
MOUNTED PROJECTOR. COORDINATE LOCATION
WITH EXISTING FURNITURE. COORDINATE WITH
FURNITURE VENDOR FOR THE INSTALLATION OF
NEW CABLE CUBBIE AT THE EXISTING
CONFERENCE TABLES. CABLE CUBBIE TO BE
PROVIDED BY OWNER.
6
DEMOLISH REMOVE AND DISCARD EXISTING
PANTRY MILLWORK. RELOCATE EXISTING
PLUMBING TO CONFORM TO NEW PANTRY
LAYOUT
7
DEMOLISH REMOVE AND DISCARD EXISTING
PARTITIONS REMOVE ALL POWER TO NEAREST
JUNCTION BOX, COORDINATE REMOVAL OF
DATA WITH TENANT.
8
CONTRACTOR TO COORDINATE POWER TO TABLE
TOP PRINTER(S) AND FAX(ES) WITH FURNITURE
VENDOR, PROVIDE ADDITIONAL CIRCUITS IF
NECESSARY.
9
PROVIDE FILM BAND UP TO 5'-6" A.F.F. SEE
ELEVATION.
TO BE RELOCATED, AS
SHOWN
X 1'-9" H
TO BE RELOCATED, AS
SHOWN
X 1'-6" H
TO BE RELOCATED, AS
SHOWN
X 1'-6" H
TO BE RELOCATED, AS
SHOWN
11 DEMOLISH REMOVE AND DISCARD ELECTRIC
WATER HEATHER IN CEILING.
TO BE RELOCATED,
CONTRACTOR TO
VERIFY PLUG TYPE
12 CONTRACTOR TO COORDINATE THE POWER AND
DATA CONNECTIONS FOR PRINTER. USE EXISTING
POWER AND DATA AT COLUMN, DO NOT
CONNECT EQUIPMENT TO WORKSTATION.
TO BE RELOCATED, AS
SHOWN
13
NO
01
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
1
A341
A323
A314
4 3
4 3
4 3
OFFICE
EQ-22
10 EXISTING EXECUTIVE PANTRY TO BE GUTTED,
DEMOLISH REMOVE AND DISCARD EXISTING
MILLWORK; SAFE OFF AND CAP EXISTING
ELECTRICAL AND PLUMBING. CONTRACTOR
SHALL COORDINATE LOCATION OF ALL NEW
ELECTRICAL WITH FURNITURE VENDOR AND
TENANT.
1
4 3
4 3
4 3
4 3
5
CONF. RM.
4 3
3
H
A324
8
CONTRACTOR SHALL VERIFY MAX. SIDE LITE WIDTH
@ THIS LOCATION.
-
N
A330
OFFICE
2
OFFICE
A329
OFFICE
NO SIDE LITE AT THIS LOCATION.
14
A312
A313
1
TO BE RELOCATED, AS
SHOWN
2820
5
A342
EQ-21
8'-2"
4 3
EQ-11
EQ-14
OFFICE
EQ-30
8
A326
EQ-2
EQ-28
4
9
4
CONF. ROOM
OFFICE
A-7
4
OFFICE
A345
4
A311
LASER JET DESKTOP PRINTER
X 1'-4" H
1
5
OFFICE
X 2'-6" H
TO BE RELOCATED, AS
SHOWN
10 11
4 3
A309
X 3'-5" H
1
X 1'-6" H
SEE EQUIPMENT SCHEDULE FOR PLUG
REQUIREMENT.
3'-0" 9 3/8"
ADMIN.
4 3
ADMIN.
4 3
4 3
17
4 3
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-1A_Construction.dwg, 11/20/2012 5:04:15 PM
4 3
4 3
EQ-8
ADMIN.
TO BE RELOCATED, AS
SHOWN
SHEET NOTES:
TYP.
ADMIN.
X 1'-4" H
A340
OFFICE
3'-0"
TO BE RELOCATED, AS
SHOWN
4
EQ-7
UNDER COUNTER REFRIGERATOR
SUMMIT
APPLIANCE
FF6ADA
WHITE
SUPPLIED & INSTALLED BY
CONTRACTOR
EQ-25
FULL SIZE REFRIGERATOR
GE
GTH21KBXWW
NEW
PROVIDED BY TENANT AND
INSTALLED BY
CONTRACTOR
17 PROTECT EXISTING WALL COVERING TO REMAIN
IN THIS AREA. SEE FINISH PLAN.
EQ-26
2.0 CU. FT. COUNTERTOP
MICROWAVE OVEN
G.E. PROFILE
PEB2060DMWW
WHITE
SUPPLIED BY TENANT
INSTALLED BY
CONTRACTOR
18 NEW DOOR, NEW HARDWARE OFFICE FUNCTION,
MATCH BUILDING STANDARD FINISH, BRUSHED
CHROME.
EQ-27
ADA STAINLESS STEEL BOWL SINK
ELUHAD2115
STAINLESS STEEL
UNDERMOUNT
SUPPLIED & INSTALLED BY
CONTRACTOR
STAINLESS STEEL
MATCH EXISTING
SUPPLIED & INSTALLED BY
CONTRACTOR
SUPPLIED BY TENANT,
CONTRACTOR TO PROVIDE
WATER CONNECTION W/
SHUT OFF
PLUG - NEMA 5-15R
PROVIDED BY
CONTRACTOR
19
1
OFFICE
4
16
PHASE II
1
1
4
5
EQ-28
A316
A317
A318
A319
A320
A321
A322
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
OFFICE
OFFICE
EQ-29
EQ-30
CONSTRUCTION/ DEMOLITION PLAN (A) - SHOWING FURNITURE & POWER
SCALE: 1/8" = 1'-0"
1
15 NEW WALL TALKER. REFER TO ELEVATION 6/A-6
FOR TYPICAL ELEVATION.
EQ-24
1
A315
14 PROVIDE POWER FOR WINDOW TREATMENT, SEE
FINISH PLAN FOR MORE INFORMATION.
ADA FAUCET
-
WATER DISPENSER
-
-
PROVIDE 1/4"
WATER LINE
PRINTER
CANON
3245
-
16 REMOVE EXISTING WALL COVERING AND PREP
FOR NEW FINISH.
19 EXISTING WALL COVERING, CARPET AND BASE TO
REMAIN, G.C. TO PROTECT AS REQUIRED.
ALTERNATES:
A.
GENERAL CONTRACTOR TO PROVIDE
DEDUCT UNIT PRICE FOR SIDE LIGHTS AT
OFFICE LOCATIONS.
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
CONSTRUCTION/ DEMOLITION
PLAN (A) - SHOWING
FURNITURE & POWER
A-1A
B314
B315
B316
B317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
E
E
E
SYM.
SYM.
TYPE
3
WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED. NUMBER REPRESENTS
AMOUNT OF RECEPTICLES AT SYSTEM FURNITURE
DESCRIPTION
MANUFACTURER
MODEL NUMBER
EQ-1
MULTI FUNCTION PRINTER/COPIER
BY TENANT
CANON
5055
EQ-2
PAPER SHREDDER BIN
-
-
NOTES
EXISTING
NOTES
E
B318a
WALL MTD. QUAD RECEPTACLE, "R" DENOTES RELOCATED
1.
CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING WORK OF ALL CONSULTANTS AND
SUBCONTRACTORS, WHETHER HIRED BY THE OWNER
OR BY CONTRACTOR.
2.
CONTRACTOR IS RESPONSIBLE FOR ALL WORK
IDENTIFIED ON ALL DRAWINGS UNLESS OTHERWISE
NOTED.
3.
SHADED AREA ON PLAN INDICATES AREAS OUTSIDE
SCOPE OF WORK (NIC).
4.
REFER TO PLAN FOR ALL ELEVATION TAGS.
5.
ALL NEW INTERIOR FRAMING SHALL MATCH EXISTING
2X CONSTRUCTION OF ADJACENT WALLS U.O.N.
AND ARE SHOWN SHADED ON PLAN.
INSTALLED BY
CONTRACTOR. SPECIAL
PLUG - NEMA 5-20R
DEDICATED WALL MTD. DUPLEX RECEPTACLE, "R" DENOTES RELOCATED
E
E
GENERAL NOTES:
EQUIPMENT SCHEDULE
ELECTRICAL SYMBOLS
B313
TO BE RELOCATED
(FLOOR STANDING)
OFFICE
R
R
R
1
3-drawer
WALL MTD. GFCI DUPLEX RECEPTACLE
GFCI
R
E
B318b
ADMIN.
ADMIN.
18487224
3-drawer
E
E
N
5-drawer
18487224
WALL MTD. VOICE RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5 HOME
RUNS
2
E
E
18487224
3-drawer
E
4
WALL MTD. COMBINATION VOICE/DATA RECEPTACLE, NUMBER REPRESENTS
AMOUNT OF CAT5 HOME RUNS
1
WALL MTD. CABLE/DATA RECEPTACLE, NUMBER REPRESENTS AMOUNT OF CAT 5
HOME RUNS
3
E
B319b
24724818
18487224
24724818
E
CR
CARD READER
EB
EGRESS OVERRIDE BUTTON
E
B320
24724818
18487224
5-drawer
E
TO BE RELOCATED, AS
SHOWN
EQ-4
LASER JET DESKTOP PRINTER
HP
4250
TO BE RELOCATED, AS
SHOWN
EQ-5
LASER PRINTER/COPIER BY TENANT
CANON
2050
X 1'-4" H
TO BE RELOCATED, AS
SHOWN
X 2'-6" H
6.
DIMENSIONS SHOWN ARE MEASURED FROM FACE
OF FINISH WALL.
TO BE RELOCATED, AS
SHOWN
7.
CONTRACTOR SHALL PROVIDE FIRE RETARDANT
BLOCKING IN WALLS AS REQUIRED FOR MILLWORK,
LCD TV'S, ETC.
X 1'-4" H
TO BE RELOCATED, AS
SHOWN
8.
THE ENTIRE AREA IN SCOPE SHALL BE THOROUGHLY
CLEANED, INCLUDING WAXING & POLISHING AT THE
COMPLETION OF CONSTRUCTION.
H
TO BE RELOCATED, AS
SHOWN
9.
REFER TO FINISH PLAN ON A-4A & A-4B FOR ALL NEW
FINISHES.
10. REFER TO REFLECTED CEILING PLAN ON A-3A & A-3B
FOR NEW LIGHTING SPECIFICATION.
EQ-6
POWER SHRED
FELLOWS
C-120
EQ-7
FAX
PITNEY BOWES
1630
EQ-8
LASER JET DESKTOP PRINTER
HP
NJ2AVXTECPRT11
EQ-9
FAX
TOSHIBA
-
TO BE RELOCATED, AS
SHOWN
5185
PLUG - NEMA 5-20R TO BE
PROVIDED BY
CONTRACTOR
RECESSED FLOOR BOX , FSR 500P-S-C - 3" DEEP, CONFIRM WITH TENANT
COMPONENTS WITH
N
3
4015
WALL MTD. CABLE T.V. CONNECTION
OFFICE
E
5'-33
4"
HP
B319a
OFFICE
24724818
18487224
18487224
3-drawer
N
E
24724818
24724818
ADMIN.
3-drawer
FLOOR MTD. "POWER INFEED" FOR VOICE/ DATA AND ELECTRICAL
CONNECTIONS TO MODULAR FURNITURE. CUT AND PATCH SLAB ACCORDINGLY
FOR FEED AND CONDUIT. RELOCATE EXISTING POWER IN-FEED AS INDICATED ON
PLAN FOR NEW FURNITURE LAYOUT. COORDINATE EXACT LOCATION WITH
FURNITURE VENDOR. "R" AND "N" DENOTE RELOCATED AND NEW, "E" DENOTES
EXISTING.
OFFICE
3'-71"
2
ADMIN.
LASER JET DESKTOP PRINTER
E
R
3-drawer
WALL MTD. "POWER INFEED" FOR VOICE/ DATA CONNECTIONS TO MODULAR
FURNITURE. COORDINATE W/ FURNITURE VENDOR. "R" AND "N" DENOTE
RELOCATED AND NEW. "E" DENOTES EXISTING.
EQ-3
OFFICE
INFRARED OVERHEAD RELEASE
IR
MULTI FUNCTION PRINTER/COPIER
BY TENANT
CANON
EQ-11
ENERGY STAR MINI FRIDGE
-
-
REMOVED FROM THE PLAN
EQ-12
LASER JET DESKTOP PRINTER
HP
9050
TO BE RELOCATED, AS
SHOWN
EQ-10
E
EXISTING DATA AND DUPLEX TO REMAIN
E
3-drawer
3-drawer
B321
8
OFFICE
EQ-17 EQ-2
EQ-13
2-drawer
EQ-14
24724818
R
18487224
IKON CANON
DESKTOP FAX
BROTHER
INTELLIFAX
CLASS -810
TO BE RELOCATED, AS
SHOWN
2820
TO BE RELOCATED, AS
SHOWN
E
R
E
9
LASER PRINTER/COPIER BY TENANT
E
B322
OFFICE
EQ-15
PHASE III
E
24724818
5-drawer
18487224
B323
E
5'-10"
R
C301
C302
C303
C304
C305
C306
C307
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
9
18487224
10
1
A-6
A-6
24724818
E
E
E
3-drawer
R
3-drawer
3-drawer
R
3'-101"
2
3'-01"
2
N
E
3-drawer
ADMIN.
EQ-4
4-drawer
N
N
E
N
E
3-drawer
E
E
E
OFFICE
EQ-28
EQ-25
EQ-24
3-drawer
EQ-1
EQ-26
R
EQ-29
CLASS-730I
EQ-21
MULTI FUNCTION PRINTER/COPIER
BY TENANT
GENICOM
5000
R
4'73
4"
5-drawer
EQ-22
FAX
LEXMARK
AVFLTLAZERO6
EQ-23
LOCKABLE CABINET
-
-
TO BE RELOCATED, AS
SHOWN
X 3'-5" H
TO BE RELOCATED,
CONTRACTOR TO
VERIFY PLUG TYPE
SHEET NOTES:
EQ-24
UNDER COUNTER REFRIGERATOR
SUMMIT
APPLIANCE
EQ-25
FULL SIZE REFRIGERATOR
EQ-26
X 1'-6" H
TO BE RELOCATED, AS
SHOWN
1
NO SIDE LITE AT THIS LOCATION.
2
CONTRACTOR SHALL VERIFY MAX. SIDE LITE WIDTH
@ THIS LOCATION.
3
REMOVE EXISTING POWER AND DATA INFEED AT
FLOOR OR WALL, SAFE OFF AND PATCH AS
REQUIRED
FF6ADA
WHITE
SUPPLIED & INSTALLED BY
CONTRACTOR
4
GE
GTH21KBXWW
NEW
PROVIDED BY TENANT AND
INSTALLED BY
CONTRACTOR
REMOVE DOOR, FRAME, & HARDWARE. INFILL
WALL SECTION TO MATCH EXISTING ADJACENT
WALL AS REQUIRED. PROVIDE NEW SIDELIGHT IN
INDICATED LOCATIONS.
5
2.0 CU. FT. COUNTERTOP
MICROWAVE OVEN
G.E. PROFILE
PEB2060DMWW
WHITE
SUPPLIED BY TENANT
INSTALLED BY
CONTRACTOR
EQ-27
ADA STAINLESS STEEL BOWL SINK
ELUHAD2115
STAINLESS STEEL
UNDERMOUNT
SUPPLIED & INSTALLED BY
CONTRACTOR
EQ-28
ADA FAUCET
-
STAINLESS STEEL
MATCH EXISTING
SUPPLIED & INSTALLED BY
CONTRACTOR
CORE FLOOR FOR NEW TABLE TOP POWER &
DATA AT CONFERENCE TABLE. PROVIDE SEPARATE
CORES, ONE 3 4" FOR DUPLEX OUTLET & ONE 2"
FOR AV &DATA BELOW THE TABLE. AN
ADDITIONAL 2" CORE IN AN ADJACENT WALL TO
RUN CABLE FROM TABLE TOP TO CEILING
MOUNTED PROJECTOR. COORDINATE LOCATION
WITH EXISTING FURNITURE. COORDINATE WITH
FURNITURE VENDOR FOR THE INSTALLATION OF
NEW CABLE CUBBIE AT THE EXISTING
CONFERENCE TABLES. CABLE CUBBIE TO BE
PROVIDED BY OWNER.
6
PROVIDE 1/4"
WATER LINE
SUPPLIED BY TENANT,
CONTRACTOR TO PROVIDE
WATER CONNECTION W/
SHUT OFF
DEMOLISH REMOVE AND DISCARD EXISTING
PANTRY MILLWORK. RELOCATE EXISTING
PLUMBING TO CONFORM TO NEW PANTRY
LAYOUT
7
-
PLUG - NEMA 5-15R
PROVIDED BY
CONTRACTOR
DEMOLISH REMOVE AND DISCARD EXISTING
PARTITIONS REMOVE ALL POWER TO NEAREST
JUNCTION BOX, COORDINATE REMOVAL OF
DATA WITH TENANT.
EQ-23
8
CONTRACTOR TO COORDINATE POWER TO TABLE
TOP PRINTER(S) AND FAX(ES) WITH FURNITURE
VENDOR, PROVIDE ADDITIONAL CIRCUITS IF
NECESSARY.
3-drawer
ALIGN
9
PROVIDE FILM BAND UP TO 5'-6" A.F.F. SEE
ELEVATION.
3-drawer
3-drawer
CANON
5-drawer
3-drawer
3-drawer
1"
3'-62
PHASE I
3-drawer
3245
OFFICE
18487224
18487224
24724818
18487224
C314
3'-6"
24724818
24724818
24724818
24724818
18487224
PRINTER
OFFICE
5-drawer
3-drawer
1"
3'-64
E
-
E
18487224
4'-21"
4
-
C313
E
4-drawer
3-drawer
WATER DISPENSER
E
E
E
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
R
24724818
24724818
24724818
24724818
24724818
18487224
18487224
18487224
18487224
18487224
18487224
11 DEMOLISH REMOVE AND DISCARD ELECTRIC
WATER HEATHER IN CEILING.
C315
E
OFFICE
8
E
E
2'-01"
4
EQ-3
PE
18487224
EQ-30
12
18487224
18487224
18487224
E
24724818
24724818
E
OFFICE
24724818
24724818
C327b
PE
13
E
24724818
24724818
24724818
24724818
24724818
ADMIN.
18487224
18487224
18487224
ADMIN.
18487224
E
18487224
ADMIN.
C327a
12 CONTRACTOR TO COORDINATE THE POWER AND
DATA CONNECTIONS FOR PRINTER. USE EXISTING
POWER AND DATA AT COLUMN, DO NOT
CONNECT EQUIPMENT TO WORKSTATION.
E
13
E
ADMIN.
C316
E
15 NEW WALL TALKER. REFER TO ELEVATION 6/A-6
FOR TYPICAL ELEVATION.
E
2
3-drawer
E
E
3-drawer
3-drawer
3-drawer
3-drawer
E
3-drawer
16 REMOVE EXISTING WALL COVERING AND PREP
FOR NEW FINISH.
E
17 PROTECT EXISTING WALL COVERING TO REMAIN
IN THIS AREA. SEE FINISH PLAN.
1
R
R
R
R
R
E
E
E
E
E
E
E
E
E
R
1
R
E
E
E
E
19 EXISTING WALL COVERING, CARPET AND BASE TO
REMAIN, G.C. TO PROTECT AS REQUIRED.
E
E
ALTERNATES:
A.
C326
C325
C324
C323
C322
C321
C320
C319
C318
C317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONSTRUCTION/ DEMOLITION PLAN (B) - SHOWING FURNITURE & POWER
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
18 NEW DOOR, NEW HARDWARE OFFICE FUNCTION,
MATCH BUILDING STANDARD FINISH, BRUSHED
CHROME.
E
E
SEE EQUIPMENT SCHEDULE FOR PLUG
REQUIREMENT.
14 PROVIDE POWER FOR WINDOW TREATMENT, SEE
FINISH PLAN FOR MORE INFORMATION.
OFFICE
OFFICE
SCALE: 1/8" = 1'-0"
NO
10 EXISTING EXECUTIVE PANTRY TO BE GUTTED,
DEMOLISH REMOVE AND DISCARD EXISTING
MILLWORK; SAFE OFF AND CAP EXISTING
ELECTRICAL AND PLUMBING. CONTRACTOR
SHALL COORDINATE LOCATION OF ALL NEW
ELECTRICAL WITH FURNITURE VENDOR AND
TENANT.
R
OFFICE
X 1'-6" H
TO BE RELOCATED, AS
SHOWN
E
PHASE II
TO BE RELOCATED, AS
SHOWN
3'-0"
EQ-30
4
E
OFFICE
C328
X 1'-6" H
E
E
4
4'-81"
4
E
C329
CANON
EQ-29
5-drawer
R
4
OFFICE
MULTI FUNCTION PRINTER/COPIER
BY TENANT
19. CONTRACTOR TO RELOCATE ALL SWITCHES AS
REQUIRED DUE TO INSTALLATION OF NEW
SIDELIGHTS.
OFFICE
N
N N
C331
E
OFFICE
14
CONF. RM.
EQ-20
TO BE RELOCATED, AS
SHOWN
C312
E
6
4-drawer
CONF. RM.
CLASS-730I
X 1'-9" H
E
C343
EQ-27
E E
EQ-10
E
C330
CANON
18. CONTRACTOR TO MODIFY OR RELOCATE EXISTING
POWER AND DATA INFEED AS REQUIRED BY NEW
FURNITURE.
OFFICE
15
C332
LASER FAX
17. PROVIDE 3'-0" WIDE TRIMMED OPENING AND SIDE
LITE TO MATCH EXISTING (ALUMINUM EXTRUDED
GLASS CHANNEL WITH REMOVABLE STOP) TO ALL
PERIMETER OFFICES U.O.N. SEE DETAIL # 1 ON A-6.
TO BE RELOCATED, AS
SHOWN
C311
E
EQ-15
A330
EQ-19
R
A-5
14
STUDIO 170F
16. GC SHALL REMOVE AND DISCARD ALL EXISTING 1X2
ACCENT WOOD TRIM BAND CURRENTLY INSTALLED
BETWEEN DOOR AT VARIOUS LOCATIONS
THROUGHOUT OPEN OFFICE AREAS.
H
OFFICE
3
5
TOSHIBA
15. EXISTING POWER AND DATA AT OFFICES TO REMAIN
U.O.N.
E
N
24724818
18487224
5'-93
4"
E
EQ-17
EQ-19
9
A-6
MULTI FUNCTION PRINTER/COPIER
BY TENANT
14. DIMENSIONS AT FURNITURE LOCATIONS TO BE
COORDINATED AND CONFIRMED WITH FURNITURE
VENDOR, FURNITURE VENDOR WILL BE MARKING
OUT LOCATIONS OF FLOOR BOXES AND PANELS
C310
2-drawer
5-drawer
E
EQ-18
13. CONTRACTOR SHALL BE RESPONSIBLE FOR
REMOVING ALL EXISTING CARPET, TILE, AND BASE IN
AREAS OF WORK. CONTRACTOR SHALL PREPARE
ALL SURFACES AS REQUIRED TO RECEIVE NEW
FINISHES.
01
ADMIN.
16
8
P4650N
12. ALL NEW OUTLETS SHALL BE MTD. @ 18" A.F.F. U.O.N.
E
1
R
HP
11. SEE EQUIPMENT SCHEDULE & ELECTRICAL SYMBOLS
THIS SHEET FOR MORE INFORMATION.
C309
OFFICE
1
3'-43
4"
1"
3'-52
3'-03"
4
E
A-7
LASER JET DESKTOP PRINTER
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
1
A-6
16
EQ-17
H
TO BE RELOCATED, AS
SHOWN
CERITFICATE OF AUTHORIZATION # AC-710
C308
N
24724818
3-drawer
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-1B_Construction.dwg, 11/20/2012 5:04:38 PM
E
18487224
03
7
E
E
24724818
18487224
3-drawer
24724818
PE N
24724818
E
R
3-drawer
24724818
18487224
P4015N
OFFICE
R
3-drawer
24724818
3-drawer
24724818
E
E
4-drawer
PE
E
E
R
3'-01"
4
N
E
TYP.
R
5'-8"
6'-63
4"
18487224
03
E
E
18487224
24724818
E
E
18487224
N
E
18487224
HP
A-6
EQ-10
5'-2"
24724818
LASER JET DESKTOP PRINTER
-
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
5
18487224
4
24724818
12
5-drawer
4
N
18487224
03
EQ-16
-
E
PE
E
-
CONF. RM.
E
18487224
24724818
1"
5'-54
-
OFFICE
C300
R
NOT USED
s t u d i o 1 2 0 0, LLC
1
CONSTRUCTION/ DEMOLITION
PLAN (B) - SHOWING
FURNITURE & POWER
GENERAL CONTRACTOR TO PROVIDE
DEDUCT UNIT PRICE FOR SIDE LIGHTS AT
OFFICE LOCATIONS.
A-1B
B307
B308
B309
B310
B311
B312
B313
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
GENERAL NOTES:
SYMBOLS
SYM.
TYPE
EXISTING 2X4 CEILING GRID TO REMAIN AND
BE PAINTED. NEW TILE ARMSTRONG DUNE
1773 2'X4' SQUARE EDGE LAY IN
EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
1.
ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED
AS REQUIRED SEE A-3A AND A-3B
2.
ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC.
SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE
ALL ABANDON WIRING AND RE-CIRCUIT AS
REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B
3.
ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN
U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR
RELOCATING ANY AS A RESULT OF THIS WORK, SEE
A-3A AND A-3B.
4.
REFER TO SYMBOLS FOR ALL NEW AND EXISTING
FIXTURES AND CEILINGS.
5.
ALL EMERGENCY LIGHT FIXTURES AND CIRCUITING
TO BE RETAINED PER ALL APPLICABLE CODES.
EXISTING RECESSED LIGHT FIXTURE TO BE
REMOVED U.O.N.
EXISTING CEILING MTD. DIFFUSER
EXISTING CEILING MTD. RETURN GRILLE
B306
OFFICE
EXISTING CEILING MTD. SMOKE DETECTOR
6.
CONTRACTOR SHALL ENSURE THAT AT COMPLETION
OF WORK ALL LIGHT FIXTURES ARE IN WORKING
CONDITION, WITH OPERABLE LAMPS.
APPROXIMATE EXISTING SPRINKLER HEAD
LOCATION
7.
EXISTING ILLUMINATED EXIST SIGN, ARROW
INDICATE DIRECTION HATCH INDICATES FACE
OF LETTERING
ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS
ARE TO BE REMOVED AND REPLACED AS INDICATED
ON A-3A AND A-3B
8.
SD
B305
OFFICE
EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
9.
EXISTING FIRE STROBE TO REMAIN U.N.O.
B304
OFFICE
ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS
INDICATED ON SHEET A-3A AND A-3B.
EXISTING CEILING SPEAKERS TO BE REMOVED AND
REINSTALLED BY AVIS BUDGET GROUP (ABG)
VENDOR. GC TO COORDINATE WITH ABG AND
VENDOR.
s t u d i o 1 2 0 0, LLC
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
10. EXISTING MOTION SENSORS TO BE REMOVED AND
REINSTALLED BY GC COORDINATE WITH ABG.
M
EXISTING MICROPHONE IN CEILING TO
REMAIN
W
EXISTING WIFI INTERNET BOOSTER
C
EXISTING CAMERA TO REMAIN
11. REMOVE ALL EXISTING CEILING TILE IN THE AREA OF
WORK AND PAINT EXISTING GRID, PROTECT ALL
EXISTING DEVICES SCHEDULED TO REMAIN.
P
EXISTING PROJECTOR TO REMAIN
12. EXIT SIGNS TO REMAIN.
S
EXISTING SPEAKERS/INTERCOM TO REMAIN
B303
PHASE III
OFFICE
KEY NOTES:
1
REMOVE EXISTING CEILING GRID AT THIS LOCATION.
B302
OFFICE
B301
OFFICE
B300
OFFICE
A308
A307
A306
A305
A304
A303
A302
A301
A300
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
1
NO
01
A309
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-2A_RCP.Demo.dwg, 11/20/2012 5:05:00 PM
OFFICE
1
A310
A343
OFFICE
OFFICE
A327
A328
OFFICE
OFFICE
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
A345
CONF. ROOM
A311
A326
OFFICE
OFFICE
A342
OFFICE
1
A325
OFFICE
A312
A329
A330
OFFICE
CONF. RM.
CONF. RM.
A324
OFFICE
A313
OFFICE
PLAN B
A341
CONF. RM.
A323
A314
OFFICE
OFFICE
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
A340
OFFICE
A315
OFFICE
1
REFLECTED CEILING
DEMOLITION PLAN (A)
A316
A317
A318
A319
A320
A321
A322
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
OFFICE
OFFICE
REFLECTED CEILING DEMOLITION PLAN (A)
SCALE: 1/8" = 1'-0"
1
A-2A
B313
B314
B315
B316
B317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
GENERAL NOTES:
SYMBOLS
SYM.
TYPE
EXISTING 2X4 CEILING GRID TO REMAIN AND
BE PAINTED. NEW TILE ARMSTRONG DUNE
1773 2'X4' SQUARE EDGE LAY IN
B318a
EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
OFFICE
1.
ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED
AS REQUIRED SEE A-3A AND A-3B
2.
ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC.
SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE
ALL ABANDON WIRING AND RE-CIRCUIT AS
REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B
3.
ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN
U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR
RELOCATING ANY AS A RESULT OF THIS WORK, SEE
A-3A AND A-3B.
4.
REFER TO SYMBOLS FOR ALL NEW AND EXISTING
FIXTURES AND CEILINGS.
5.
ALL EMERGENCY LIGHT FIXTURES AND CIRCUITING
TO BE RETAINED PER ALL APPLICABLE CODES.
EXISTING RECESSED LIGHT FIXTURE TO BE
REMOVED U.O.N.
EXISTING CEILING MTD. DIFFUSER
S
S
S
PHASE III
B318b
OFFICE
EXISTING CEILING MTD. RETURN GRILLE
EXISTING CEILING MTD. SMOKE DETECTOR
6.
CONTRACTOR SHALL ENSURE THAT AT COMPLETION
OF WORK ALL LIGHT FIXTURES ARE IN WORKING
CONDITION, WITH OPERABLE LAMPS.
APPROXIMATE EXISTING SPRINKLER HEAD
LOCATION
7.
ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS
ARE TO BE REMOVED AND REPLACED AS INDICATED
ON A-3A AND A-3B
SD
B319a
OFFICE
W
EXISTING ILLUMINATED EXIST SIGN, ARROW
INDICATE DIRECTION HATCH INDICATES FACE
OF LETTERING
S
EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
B319b
OFFICE
S
EXISTING FIRE STROBE TO REMAIN U.N.O.
9.
ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS
INDICATED ON SHEET A-3A AND A-3B.
EXISTING CEILING SPEAKERS TO BE REMOVED AND
REINSTALLED BY AVIS BUDGET GROUP (ABG)
VENDOR. GC TO COORDINATE WITH ABG AND
VENDOR.
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
10. EXISTING MOTION SENSORS TO BE REMOVED AND
REINSTALLED BY GC COORDINATE WITH ABG.
M
EXISTING MICROPHONE IN CEILING TO
REMAIN
W
EXISTING WIFI INTERNET BOOSTER
C
EXISTING CAMERA TO REMAIN
11. REMOVE ALL EXISTING CEILING TILE IN THE AREA OF
WORK AND PAINT EXISTING GRID, PROTECT ALL
EXISTING DEVICES SCHEDULED TO REMAIN.
P
EXISTING PROJECTOR TO REMAIN
12. EXIT SIGNS TO REMAIN.
S
EXISTING SPEAKERS/INTERCOM TO REMAIN
B320
OFFICE
8.
s t u d i o 1 2 0 0, LLC
KEY NOTES:
B321
OFFICE
REMOVE EXISTING CEILING GRID AT THIS LOCATION.
S
B322
OFFICE
B323
OFFICE
C300
CONF. RM.
S
S
C301
C302
C303
C304
C305
C306
C307
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
C308
S
OFFICE
C309
OFFICE
S
S
NO
S
ISSUE
DATE
S
01
S
S
FOR BID & PERMIT
11.19.2012
C310
S
OFFICE
W
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-2B_RCP.Demo.dwg, 11/20/2012 5:05:09 PM
E
E
E
E
C311
OFFICE
PHASE I
S
E
E
E
C343
E
OFFICE
C312
S
C331
OFFICE
OFFICE
E
E
E
E
E
E
E
E
C313
OFFICE
F
A330
CONF. RM.
C332
C330
CONF. RM.
OFFICE
S
S
S
4
S
C329
C314
OFFICE
OFFICE
W
PLAN A
C328
OFFICE
C315
OFFICE
C327b
OFFICE
S
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
C316
S
C327a
OFFICE
OFFICE
S
S
REFLECTED CEILING
DEMOLITION PLAN (B)
REFLECTED CEILING DEMOLITION PLAN (B)
SCALE: 1/8" = 1'-0"
C326
C325
C324
C323
C322
C321
C320
C319
C318
C317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1
A-2B
B307
B308
B309
B310
B311
B312
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
B313
OFFIC
GENERAL NOTES:
SYMBOLS
1.
ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED
AS REQUIRED SEE A-3A AND A-3B
EXISTING 2X4 CEILING GRID TO REMAIN AND
BE PAINTED. NEW TILE ARMSTRONG DUNE
1773 2'X4' SQUARE EDGE LAY IN
2.
ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC.
SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE
ALL ABANDON WIRING AND RE-CIRCUIT AS
REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B
EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
3.
ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN
U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR
RELOCATING ANY AS A RESULT OF THIS WORK, SEE
A-3A AND A-3B.
4.
REFER TO SYMBOLS FOR ALL NEW AND EXISTING
FIXTURES AND CEILINGS.
5.
ALL EMERGENCY EMERGENCY LIGHT FIXTURES AND
CIRCUITING TO BE RETAINED PER ALL APPLICABLE
CODES.
6.
CONTRACTOR SHALL ENSURE THAT AT COMPLETION
OF WORK ALL LIGHT FIXTURES ARE IN WORKING
CONDITION, WITH OPERABLE LAMPS, ALL AT SAME
COLOR TEMPERATURE.
7.
ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS
ARE TO BE REMOVED AND REPLACED AS INDICATED
ON A-3A AND A-3B
SYM.
TYPE
EXISTING RECESSED LIGHT FIXTURE TO BE
REMOVED U.O.N.
EXISTING CEILING MTD. DIFFUSER
B306
OFFICE
EXISTING CEILING MTD. RETURN GRILLE
SD
APPROXIMATE EXISTING SPRINKLER HEAD
LOCATION
5
B305
EXISTING CEILING MTD. SMOKE DETECTOR
EXISTING ILLUMINATED EXIST SIGN, ARROW
INDICATE DIRECTION HATCH INDICATES FACE
OF LETTERING
OFFICE
8.
ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS
INDICATED ON SHEET A-3A AND A-3B.
9.
CONTRACTOR SHALL NOTIFY ARCHITECT
IMMEDIATELY OF POTENTIAL OR ACTUAL CONFLICTS
W/ LIGHTING AND ABOVE CEILING DUCTS, PIPES,
ETC.
EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
NEW 2'X4' LIGHTOLIER COFFAIRE II
DIRECT/INDIRECT RECESSED
CFH2GPF232277HI 3 LAMP SUPER T-8.
B304
OFFICE
NEW 2'X2' LIGHTOLIER COFFAIRE II
DIRECT/INDIRECT RECESSED
CFH2GPF217277SBGLR 3 LAMP T-8.
NEW PENDANT LIGHTING TBD
B303
s t u d i o 1 2 0 0, LLC
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
10. PLANS INDICATE EXISTING LOCATIONS FOR
SPRINKLERS GC TO COORDINATE RELOCATION OF
SPRINKLERS HEADS, HVAC DIFFUSERS, HVAC RETURN
AIR GRILLS AND OTHER CEILING MTD DEVICES AS
REQUIRED BY NEW LIGHTING LAYOUT.
OFFICE
LYTECASTER 5' DIA. LED RECESSED DOWN
LIGHT. 277V / DIMMABLE / 900 LUMEN 3500 K
LAMP / FRAME IN KIT 1001LED09N35D2 /
WHITE CONE
SHEET NOTES:
EXISTING FIRE STROBE TO REMAIN U.N.O.
B302
M
OFFICE
W
1
PATCH AND REPAIR GRID TO LIKE NEW
CONDITIONS AS REQUIRED PRIOR TO PAINTING
AREA OF DEMOLITION.
2
CONTRACTOR SHALL VERIFY GRID & PROPOSED
LIGHT CONDITION IN THIS AREA. CONTRACTOR
SHALL SHIFT LIGHT TO NEXT BAY IF NECESSARY.
3
CONTRACTOR SHALL SHIFT EXISTING DIFFUSER OR
RETURN AS REQUIRED BY NEW LIGHTING LAY OUT.
4
CONTRACTOR SHALL RELOCATE EXISTING
SPRINKLER HEAD AS REQUIRED BY NEW LIGHTING
LAY OUT.
5
CONTRACTOR SHALL RELOCATE SMOKE
DETECTOR AS REQUIRED BY NEW LIGHTING LAY
OUT.
6
NEW GRID AND TILE AT THIS AREA.
7
EXTEND EXISTING GRID AS REQUIRED.
8
EXISTING GYP. BD. SOFFIT TO REMAIN.
9
EXISTING GRID AND TILE TO REMAIN IN THIS AREA.
EXISTING MICROPHONE IN CEILING TO
REMAIN
EXISTING WIFI INTERNET BOOSTER
C
EXISTING CAMERA TO REMAIN
B301
P
OFFICE
S
EXISTING PROJECTOR TO REMAIN
EXISTING SPEAKERS/INTERCOM TO REMAIN
PHASE III
B300
OFFICE
A308
A307
A306
A305
A304
A303
A302
A301
A300
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
10 DEMOLISHED CEILING GRID AND PROPOSED
CEILING GRID HEIGHTS DIFFER, GENERAL
CONTRACTOR TO VERIFY CLEARANCE ABOVE
CEILING FOR PROPOSED EQUIPMENT AND
LIGHTING, CONTACT ARCHITECT TO REVIEW
RESOLUTION OF ANY CONFLICTS PRIOR TO
INSTALLATION OF NEW MATERIAL.
6
NO
01
A309
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-3A_RCP.dwg, 11/20/2012 5:05:20 PM
OFFICE
6
4
A310
A343
OFFICE
OFFICE
A327
A328
OFFICE
OFFICE
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
A345
CONF. ROOM
A311
A326
OFFICE
OFFICE
A342
10
1
OFFICE
6
A325
OFFICE
4
4
A312
A329
A330
OFFICE
CONF. RM.
CONF. RM.
A324
OFFICE
4
5
A313
OFFICE
PLAN B
8
A341
CONF. RM.
8
A323
A314
OFFICE
OFFICE
8
A340
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
OFFICE
4
A315
OFFICE
6
REFLECTED CEILING PLAN (A)
A316
A317
A318
A319
A320
A321
A322
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
OFFICE
OFFICE
REFLECTED CEILING PLAN (A)
SCALE: 1/8" = 1'-0"
1
A-3A
B312
B313
B314
B315
B316
B317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
GENERAL NOTES:
SYMBOLS
1.
ALL EXISTING HVAC TO REMAIN AND BE RE-WORKED
AS REQUIRED SEE A-3A AND A-3B
EXISTING 2X4 CEILING GRID TO REMAIN AND
BE PAINTED. NEW TILE ARMSTRONG DUNE
1773 2'X4' SQUARE EDGE LAY IN
2.
ALL EXISTING ELECTRICAL SWITCHES, DIMMERS, ETC.
SHALL REMAIN U.O.N. CONTRACTOR TO REMOVE
ALL ABANDON WIRING AND RE-CIRCUIT AS
REQUIRED BY NEW LAYOUT, SEE A-3A AND A-3B
EXISTING 1'X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
3.
ALL EXISTING LIFE SAFETY EQUIPMENT SHALL REMAIN
U.O.N. CONTRACTOR SHALL BE RESPONSIBLE FOR
RELOCATING ANY AS A RESULT OF THIS WORK, SEE
A-3A AND A-3B.
4.
REFER TO SYMBOLS FOR ALL NEW AND EXISTING
FIXTURES AND CEILINGS.
5.
ALL EMERGENCY EMERGENCY LIGHT FIXTURES AND
CIRCUITING TO BE RETAINED PER ALL APPLICABLE
CODES.
SYM.
B318a
OFFICE
TYPE
EXISTING RECESSED LIGHT FIXTURE TO BE
REMOVED U.O.N.
EXISTING CEILING MTD. DIFFUSER
S
S
S
B318b
EXISTING CEILING MTD. RETURN GRILLE
OFFICE
SD
B319a
APPROXIMATE EXISTING SPRINKLER HEAD
LOCATION
OFFICE
W
EXISTING CEILING MTD. SMOKE DETECTOR
EXISTING ILLUMINATED EXIST SIGN, ARROW
INDICATE DIRECTION HATCH INDICATES FACE
OF LETTERING
PHASE III
S
CONTRACTOR SHALL ENSURE THAT AT COMPLETION
OF WORK ALL LIGHT FIXTURES ARE IN WORKING
CONDITION, WITH OPERABLE LAMPS, ALL AT SAME
COLOR TEMPERATURE.
7.
ALL EXISTING 1X4 LIGHT FIXTURES AND DOWN LIGHTS
ARE TO BE REMOVED AND REPLACED AS INDICATED
ON A-3A AND A-3B
8.
ALL EXISTING EXIT LIGHTS TO REMAIN, RELOCATE AS
INDICATED ON SHEET A-3A AND A-3B.
9.
CONTRACTOR SHALL NOTIFY ARCHITECT
IMMEDIATELY OF POTENTIAL OR ACTUAL CONFLICTS
W/ LIGHTING AND ABOVE CEILING DUCTS, PIPES,
ETC.
EXISTING 2X4' PARABOLIC LIGHT FIXTURE TO
BE REMOVED U.N.O.
B319b
S
6.
NEW 2'X4' LIGHTOLIER COFFAIRE II
DIRECT/INDIRECT RECESSED
CFH2GPF232277HI 3 LAMP SUPER T-8.
OFFICE
NEW 2'X2' LIGHTOLIER COFFAIRE II
DIRECT/INDIRECT RECESSED
CFH2GPF217277SBGLR 3 LAMP T-8.
B320
NEW PENDANT LIGHTING TBD
OFFICE
LYTECASTER 5' DIA. LED RECESSED DOWN
LIGHT. 277V / DIMMABLE / 900 LUMEN 3500 K
LAMP / FRAME IN KIT 1001LED09N35D2 /
WHITE CONE
B321
OFFICE
M
W
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
10. PLANS INDICATE EXISTING LOCATIONS FOR
SPRINKLERS GC TO COORDINATE RELOCATION OF
SPRINKLERS HEADS, HVAC DIFFUSERS, HVAC RETURN
AIR GRILLS AND OTHER CEILING MTD DEVICES AS
REQUIRED BY NEW LIGHTING LAYOUT.
SHEET NOTES:
1
PATCH AND REPAIR GRID TO LIKE NEW
CONDITIONS AS REQUIRED PRIOR TO PAINTING
AREA OF DEMOLITION.
2
CONTRACTOR SHALL VERIFY GRID & PROPOSED
LIGHT CONDITION IN THIS AREA. CONTRACTOR
SHALL SHIFT LIGHT TO NEXT BAY IF NECESSARY.
3
CONTRACTOR SHALL SHIFT EXISTING DIFFUSER OR
RETURN AS REQUIRED BY NEW LIGHTING LAY OUT.
4
CONTRACTOR SHALL RELOCATE EXISTING
SPRINKLER HEAD AS REQUIRED BY NEW LIGHTING
LAY OUT.
5
CONTRACTOR SHALL RELOCATE SMOKE
DETECTOR AS REQUIRED BY NEW LIGHTING LAY
OUT.
6
NEW GRID AND TILE AT THIS AREA.
7
EXTEND EXISTING GRID AS REQUIRED.
8
EXISTING GYP. BD. SOFFIT TO REMAIN.
9
EXISTING GRID AND TILE TO REMAIN IN THIS AREA.
EXISTING MICROPHONE IN CEILING TO
REMAIN
EXISTING WIFI INTERNET BOOSTER
S
C
EXISTING CAMERA TO REMAIN
B322
P
OFFICE
EXISTING PROJECTOR TO REMAIN
S
EXISTING SPEAKERS/INTERCOM TO REMAIN
B323
OFFICE
C300
CONF. RM.
C301
C302
C303
C304
C305
C306
C307
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
PHASE I
S
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
EXISTING FIRE STROBE TO REMAIN U.N.O.
R
S
s t u d i o 1 2 0 0, LLC
10 DEMOLISHED CEILING GRID AND PROPOSED
CEILING GRID HEIGHTS DIFFER, GENERAL
CONTRACTOR TO VERIFY CLEARANCE ABOVE
CEILING FOR PROPOSED EQUIPMENT AND
LIGHTING, CONTACT ARCHITECT TO REVIEW
RESOLUTION OF ANY CONFLICTS PRIOR TO
INSTALLATION OF NEW MATERIAL.
C308
S
OFFICE
C309
OFFICE
S
S
NO
S
S
01
S
S
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
C310
S
OFFICE
W
2
E
E
E
E
C311
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-3B_RCP.dwg, 11/20/2012 5:05:32 PM
A-7
OFFICE
S
E
E
E
C343
E
OFFICE
C312
S
C331
OFFICE
OFFICE
E
E
E
E
E
E
E
E
C313
OFFICE
F
A330
C332
C330
CONF. RM.
CONF. RM.
OFFICE
R
S
S
S
4
S
S
C314
C329
PLAN A
OFFICE
OFFICE
W
R
C328
OFFICE
C315
OFFICE
C327b
OFFICE
R
S
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
6
C316
S
C327a
OFFICE
S
6
OFFICE
S
6
6
REFLECTED CEILING PLAN (B)
REFLECTED CEILING PLAN (B)
SCALE: 1/8" = 1'-0"
C326
C325
C324
C323
C322
C321
C320
C319
C318
C317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1
A-3B
PAINT, WALL COVERING AND WINDOW TREATMENT SCHEDULE
TAG
P-1
MANUFACTURER
COLOR
BENJAMIN MOORE
ITEM #
FINISH
1078
FLAT AT WALLS DOOR
& FRAMES
SEMI-GLOSS
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
HILLCREST TAN
B307
B308
B309
B310
B311
B312
B313
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONTACT
TAG
P-2
BENJAMIN MOORE
BRIDGEWATER TAN
1096
FLAT FINISH
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
P-3
BENJAMIN MOORE
OAKWOOD MANOR
1095
FLAT FINISH
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
P-4
NOT USED
NOT USED
NOT USED
MANUFACTURER
NAME
COLOR/SIZE
ITEM #
CONTACT
WB-1
ARMSTRONG
NOT USED
WB-2
JOHNSONITE
4" STRAIGHT VINYL
BASE CONT. COIL
285
MORNING LIGHT
Karen Levey-Lynch
PHONE: (800) 899-8916 x 769
WB-3
JOHNSONITE
4" STRAIGHT VINYL
BASE CONT. COIL
129
SILK
Karen Levey-Lynch
PHONE: (800) 899-8916 x 769
WB-4
NOT USED
NOT USED
1
1
P-5
GENERAL NOTES:
WALL BASE SCHEDULE
NOT USED
B306
WB-5
NOT USED
NOT USED
WB-6
JOHNSONITE
NOT USED
WB-7
ARMSTRONG
4" STRAIGHT VINYL
BASE CONT. COIL
1.
CONTRACTOR SHALL FIELD VERIFY CONDITIONS
AND NOTIFY ARCHITECT OF ANY CHANGES.
2.
ALL FLOORS SHOULD BE SKIM COATED AS
NECESSARY TO ACHIEVE CLEAN SURFACES SO THAT
BLEMISHES DO NOT TELEGRAPH THROUGH FINISH
MATERIAL.
3.
ALL WALLS SHALL BE MADE READY TO RECEIVE
SCHEDULED FINISH. I.E.: FINISHED LAYER OF GYP.
BD. AS REQUIRED.
4.
ALL FINISHES SHALL BE APPLIED FREE OF SAGS,
RUNS, STREAKS, BRUSH OR ROLLER MARKS, ETC.
5.
CONTRACTOR TO RECEIVE FINAL APPROVAL ON
MATERIALS FROM ARCHITECT PRIOR TO ORDERING.
CONTRACTOR TO VERIFY ALL PRODUCT LEAD TIMES
AND ORDER MATERIAL ACCORDINGLY.
OFFICE
P-6
NOT USED
NOT USED
16
JENNIFER WALL
PHONE: 800-356-9301 x 8288
SAND
6.
FLOOR FINISH TRANSITIONS AT DOORS SHALL BE
CENTERED UNDER DOOR WHERE APPLICABLE.
7.
ALL MATERIALS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATION.
8.
ALL TRIM PAINT TO RECEIVE SEMI-GLOSS FINISH. ALL
WALL PAINT TO RECEIVE FLAT FINISH. ALL CEILING
PAINT TO RECEIVE FLAT FINISH.
WB-8
P-7
NOT USED
NOT USED
B305
P-8
P-9
BENJAMIN MOORE
SUPERWHITE
NOT USED
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
FLAT FINISH
WALL TILE SCHEDULE
OFFICE
C-1
P-2
WB-2
TAG
T-1
B304
P-10
P-11
BENJAMIN MOORE
ELK HORN
BENJAMIN MOORE
AF-105
TBD
FLAT FINISH
TBD
TBD
ITEM #
NOT USED
TBD
WC-2
TBD
WC-3
TBD
P-10
P-10
P-10
P-10
T-2
NOT USED
NOT USED
TBD
T-3
B303
T-3
DALTILE
TAG
B301
P665
B300
MANUFACTURER
SS-1
CORIAN
SS-2
NOT USED
SS-3
CAESARSTONE
OFFICE
A308
A307
A306
A305
A304
A303
A302
A301
A300
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
P-10
P-10
P-10
P-10
PL-1
NOT USED
PL-2
FORMICA
W.C.
DALTILE
KELLY HOLLAND-YOUNG
PHONE: 908-340-8400
14. FOR FLOORING REMOVAL, SEE SHEET A-1A AND
A-1B.
NAME
COLOR
SOLID SURFACE
COUNTERTOP
-
CANYON
SOLID SURFACE
COUNTERTOP
TBD
TBD
C-1
P-2
WB-2
C-1
P-3
WB-3
C-2
5342-58
MANUFACTU
RER
COLOR/SIZE
NAME
P-2
WB-2
VT-1
C-2
PLASTIC
LAMINATE
EARTH
CONTACT
DOLAN & TRAYNOR
CONTACT: CAROL DE VIETRO
PHONE: 800-696-8760
WENDIE GOTTE
CONTACT: CAESARSTONE
PHONE: (973) 474-6234
CONTACT: SAMANTHA SMITH
PHONE: 484-241-7300
FLOOR SCHEDULE
TAG
C-1
P-3
WB-3
AMTICO
LINEAR
J+J INVISION
CARPET TILE
BROKEN SLATE
MODULAR
(7950)
BENTLEY
PRINCE
STREET
INTERNATIONAL
GLAMOUR
BROADLOOM
AR0AL
A42
COLOR: LINEAR
MOCHA SIZE:
9" x 36"
COLOR: 342
COPPER
INSTALLATION:
QUARTER
TURNED
SIZE: 24" x 24"
MATERIAL
CLASSIFICATION
-
CONTACT
CONTACT: FLORENCE GARAFFA
PHONE: 732-606-9059
PROVIDE VINYL CARPET TO VINYL
TILE TRANSITION STRIP WHERE
REQUIRED. ARCHITECT TO SELECT
COLOR FROM MANUF. STANDARD
SELECTION
OFFICE
C-2
A310
P-3
WB-3
A327
A328
OFFICE
OFFICE
CLASS 1
CONTACT: SCOTT CUCCI
PHONE: 1.800.241.4586 x 7949
A-7
C-2
8IG34
0630R
7 STAR RESORTS
880110
CLASS 1
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
12' - 6" WIDTH.
1
P-10
P-10
P-3
WB-3
A345
2
OFFICE
C-2
P-3
WB-3
P-10
P-10
SS-1
OFFICE
C-2
P-10
WB-7
P-10
P-10
1 ACCENT WALL BAND THAT IS CURRENTLY
ALIGNED WITH THE DOOR FRAME AT OPEN
OFFICE AREAS SHALL BE REMOVED. PATCH
WALL AS REQUIRED PRIOR TO PAINTING.
2 REMOVE EXISTING PANTRY FLOORING. PATCH
SLAB AS REQUIRED TO RECEIVE NEW VINYL
TILE.
4 EXISTING WALL COVERING AND BASE TO
REMAIN. SEE SHEET A-1A FOR ALTERNATE IF
REQUIRED.
5 QUANTITY OF C-4 CARPET TO BE FIELD
VERIFIED. EXISTING CARPET TO REMAIN AND
PATCH WITH NEW AS REQUIRED BASED ON
FURNITURE RELOCATION.
6 REPLACE WITH NEW WB-2 WALL BASE.
7 REPAINT EXISTING CONVECTOR COVER P-11.
NO
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
FINISH SYMBOLS
FLOOR FINISH
P-10
P-10
P-3
WB-3
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
NOT USED
59224
COLOR:
SORBET
70135
TO MATCH
EXISTING
SIZE: 24" x 24"
CONTACT: MICHAEL MALFI
PHONE: 908-208-0389
CONTACT: MICHAEL MALFI
PHONE: 908-208-0389
SHAW
CONTRACT
GROUP
C-5
SHAW
CONTRACT
GROUP
CAMBRIC
5A050
COLOR: LENO
50172
TO MATCH
EXISTING
BROADLOOM
C-6
BENTLEY
PRINCE
STREET
HOLLYWOOD
SEQUEL
BROADLOOM
8HQ32
0630R
COLOR:
GATEWOOD
PARK 801507
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
C-7
BENTLEY
PRINCE
STREET
KINGS ROAD
BROADLOOM
8KR42
0630R
TBD
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
STRAIGHTFORWARD TILE
A325
P-3
WB-3
6
A312
A329
A330
OFFICE
CONF. RM.
CONF. RM.
P-3
WB-3
C-5
DOOR FINISH
C-4
OFFICE
5
COUNTER FINISH
DOOR FRAME FINISH
A342
P-10
P-10
NOT USED
A326
OFFICE
VT-1
T-3
C-5
C-3
P-10
P-10
CONF. ROOM
A311
SHEET NOTES:
WALL BASE FINISH
OFFICE
C-5
17. REPAINT EXISTING CONVECTOR COVERS IN
PERIMETER OFFICES TO MATCH ADJACENT WALL
U.O.N.
WALL FINISH
A343
OFFICE
16. ALL PERIMETER OFFICES TO RECEIVE C-2 CARPET
WITH P-3 PAINT AND WB-3.
01
1
A309
13. MATERIAL SHALL BE ORDERED FOR ALL (3) PHASES
CONCURRENTLY SO DYE LOT IS CONSISTENT.
COORDINATE WITH TENANT ON STORING OF
MATERIALS.
3 EXISTING FINISHES TO REMAIN AT THIS
LOCATION.
P-10
WB-7
1
ALL FACE AND SIDES OF GYP. BD. CEILINGS SHALL
BE PAINTED (P-8) U.O.N.
15. DOOR FRAMES TO BE PAINTED TO MATCH
ADJACENT COLOR U.O.N., SEMI-GLOSS FINISH.
REFER TO SHEET NOTES #1 BELOW FOR FURTHER
DETAIL.
OFFICE
PHASE III
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-4A_Finish.dwg, 11/20/2012 5:05:43 PM
MARACAS GLASS
LAKE SHORES BLEND
GLOSSY
SIZE: 1" x 1"
GROUT: HYDROMENT
COLOR:LINEN
H163
SURFACE SCHEDULE
LEO ALESSI
VERTICAL INTERIOR
PRODUCTS
PHONE: 212-991-4172
TBD
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
12. IF VINYL WALL COVERING EXISTS, REMOVE, PATCH
AND REPAIR TO RECEIVE NEW PAINT U.O.N.
B302
TBD
CERITFICATE OF AUTHORIZATION # AC-710
10. REFER TO A-5 FOR ALL INTERIOR ELEVATIONS.
SS-1
1
ARENSON
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
11. ALL MILLWORK SHALL BE (PL-2) PLASTIC LAMINATE
UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS
FOR MORE INFORMATION.
OFFICE
WT-1
CONTACT
NOT USED
OFFICE
WC-1
COLOR
VT-1
OFFICE
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
NAME
9.
NOT USED
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
MANUFACTURER
s t u d i o 1 2 0 0, LLC
A324
FLOOR TRANSITION
OFFICE
A313
OFFICE
C-5
P-3
WB-3
C-4
P-2
WB-2
3
A341
CONF. RM.
A323
1
A314
3
4
OFFICE
OFFICE
3
3
6
A340
A315
6
1
OFFICE
C-5
3
P-3
WB-3
C-5
P-3
WB-3
C-5
P-3
WB-3
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
3
OFFICE
6
C-5
P-3
WB-3
3
3
3
FINISH PLAN (A)
A316
A317
A318
A319
A320
A321
A322
OFFICE
OFFICE
OFFICE
OFFICE
CONF. RM.
OFFICE
OFFICE
FINISH PLAN (A)
SCALE: 1/8" = 1'-0"
1
A-4A
B312
B313
B314
B315
B316
B317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
PAINT, WALL COVERING AND WINDOW TREATMENT SCHEDULE
TAG
MANUFACTURER
COLOR
ITEM #
FINISH
P-1
BENJAMIN MOORE
HILLCREST TAN
1078
FLAT AT WALLS DOOR
& FRAMES
SEMI-GLOSS
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
P-2
BENJAMIN MOORE
BRIDGEWATER TAN
1096
FLAT FINISH
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
CONTACT
P-3
BENJAMIN MOORE
OAKWOOD MANOR
1095
FLAT FINISH
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
B318a
OFFICE
PHASE III
NOT USED
P-4
WALL BASE SCHEDULE
P-5
NOT USED
NOT USED
OFFICE
C-1
P-2
WB-2
P-6
P-10
WB-7
NOT USED
WB-1
ARMSTRONG
NOT USED
WB-2
JOHNSONITE
4" STRAIGHT VINYL
BASE CONT. COIL
285
MORNING LIGHT
Karen Levey-Lynch
PHONE: (800) 899-8916 x 769
WB-3
JOHNSONITE
4" STRAIGHT VINYL
BASE CONT. COIL
129
SILK
Karen Levey-Lynch
PHONE: (800) 899-8916 x 769
ITEM #
WB-4
NOT USED
NOT USED
WB-5
NOT USED
NOT USED
WB-6
JOHNSONITE
NOT USED
ARMSTRONG
4" STRAIGHT VINYL
BASE CONT. COIL
CONTACT
P-7
NOT USED
P-8
1.
CONTRACTOR SHALL FIELD VERIFY CONDITIONS
AND NOTIFY ARCHITECT OF ANY CHANGES.
2.
ALL FLOORS SHOULD BE SKIM COATED AS
NECESSARY TO ACHIEVE CLEAN SURFACES SO THAT
BLEMISHES DO NOT TELEGRAPH THROUGH FINISH
MATERIAL.
3.
ALL WALLS SHALL BE MADE READY TO RECEIVE
SCHEDULED FINISH. I.E.: FINISHED LAYER OF GYP.
BD. AS REQUIRED.
4.
ALL FINISHES SHALL BE APPLIED FREE OF SAGS,
RUNS, STREAKS, BRUSH OR ROLLER MARKS, ETC.
5.
CONTRACTOR TO RECEIVE FINAL APPROVAL ON
MATERIALS FROM ARCHITECT PRIOR TO ORDERING.
CONTRACTOR TO VERIFY ALL PRODUCT LEAD TIMES
AND ORDER MATERIAL ACCORDINGLY.
16
SAND
6.
FLOOR FINISH TRANSITIONS AT DOORS SHALL BE
CENTERED UNDER DOOR WHERE APPLICABLE.
7.
ALL MATERIALS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATION.
8.
ALL TRIM PAINT TO RECEIVE SEMI-GLOSS FINISH. ALL
Nancy Dougherty, AIA, LEED
WALL PAINT TO RECEIVE FLAT FINISH. ALL CEILING
NJ-AI 14861/NY-025099/CT-ARI.0011798
PAINT TO RECEIVE FLAT FINISH.
9.
ALL FACE AND SIDES OF GYP. BD. CEILINGS SHALL
BE PAINTED (P-8) U.O.N.
s t u d i o 1 2 0 0, LLC
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
NOT USED
BENJAMIN MOORE
SUPERWHITE
FLAT FINISH
WALL TILE SCHEDULE
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
TAG
MANUFACTURER
NAME
COLOR
ITEM #
CONTACT
CERITFICATE OF AUTHORIZATION # AC-710
B319b
OFFICE
P-9
NOT USED
NOT USED
T-1
NOT USED
NOT USED
10. REFER TO A-5 FOR ALL INTERIOR ELEVATIONS.
1
P-10
BENJAMIN MOORE
ELK HORN
AF-105
FLAT FINISH
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
TBD
DIANA RATAZZI
PHONE: 877-712-6567
CELL: 914-261-8603
T-2
B320
OFFICE
P-11
BENJAMIN MOORE
WC-1
TBD
WC-2
TBD
TBD
TBD
T-3
NOT USED
DALTILE
11. ALL MILLWORK SHALL BE (PL-2) PLASTIC LAMINATE
UNLESS OTHERWISE NOTED. REFER TO ELEVATIONS
FOR MORE INFORMATION.
NOT USED
MARACAS GLASS
P665
B321
OFFICE
WC-3
LAKE SHORES BLEND
GLOSSY
SIZE: 1" x 1"
GROUT: HYDROMENT
COLOR:LINEN
H163
12. IF VINYL WALL COVERING EXISTS, REMOVE, PATCH
AND REPAIR TO RECEIVE NEW PAINT U.O.N.
DALTILE
KELLY HOLLAND-YOUNG
PHONE: 908-340-8400
ARENSON
TBD
TBD
SURFACE SCHEDULE
LEO ALESSI
VERTICAL INTERIOR
PRODUCTS
PHONE: 212-991-4172
TBD
OFFICE
PHASE I
B323
TAG
MANUFACTURER
NAME
COLOR
SS-1
CORIAN
SOLID SURFACE
COUNTERTOP
SS-2
NOT USED
SS-3
CAESARSTONE
PL-1
NOT USED
PL-2
FORMICA
-
CANYON
CONTACT
DOLAN & TRAYNOR
CONTACT: CAROL DE VIETRO
PHONE: 800-696-8760
C300
CONF. RM.
C301
C302
C303
C304
C305
C306
C307
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
P-10
WB-7
SOLID SURFACE
COUNTERTOP
PLASTIC
LAMINATE
TBD
5342-58
TBD
EARTH
WENDIE GOTTE
CONTACT: CAESARSTONE
PHONE: (973) 474-6234
CONTACT: SAMANTHA SMITH
PHONE: 484-241-7300
OFFICE
TAG
1
VT-1
C309
P-2
WB-2
MANUFACTU
RER
AMTICO
COLOR/SIZE
NAME
LINEAR
AR0AL
A42
OFFICE
P-10
WB-7
C-1
C310
P-10
P-10
J+J INVISION
CARPET TILE
OFFICE
C-2
BENTLEY
PRINCE
STREET
16. ALL PERIMETER OFFICES TO RECEIVE C-2 CARPET
WITH P-3 PAINT AND WB-3.
BROKEN SLATE
MODULAR
(7950)
INTERNATIONAL
GLAMOUR
BROADLOOM
SHEET NOTES:
1 ACCENT WALL BAND THAT IS CURRENTLY
ALIGNED WITH THE DOOR FRAME AT OPEN
OFFICE AREAS SHALL BE REMOVED. PATCH
WALL AS REQUIRED PRIOR TO PAINTING.
2 REMOVE EXISTING PANTRY FLOORING. PATCH
SLAB AS REQUIRED TO RECEIVE NEW VINYL
TILE.
3 EXISTING FINISHES TO REMAIN AT THIS
LOCATION.
FLOOR SCHEDULE
C308
15. DOOR FRAMES TO BE PAINTED TO MATCH
ADJACENT COLOR U.O.N., SEMI-GLOSS FINISH.
REFER TO SHEET NOTES #1 BELOW FOR FURTHER
DETAIL.
17. REPAINT EXISTING CONVECTOR COVERS IN
PERIMETER OFFICES TO MATCH ADJACENT WALL
U.O.N.
OFFICE
C-1
13. MATERIAL SHALL BE ORDERED FOR ALL (3) PHASES
CONCURRENTLY SO DYE LOT IS CONSISTENT.
COORDINATE WITH TENANT ON STORING OF
MATERIALS.
14. FOR FLOORING REMOVAL, SEE SHEET A-1A AND
A-1B.
TBD
WT-1
B322
8IG34
0630R
COLOR: LINEAR
MOCHA SIZE:
9" x 36"
MATERIAL
CLASSIFICATION
-
CONTACT
CONTACT: FLORENCE GARAFFA
PHONE: 732-606-9059
PROVIDE VINYL CARPET TO VINYL
TILE TRANSITION STRIP WHERE
REQUIRED. ARCHITECT TO SELECT
COLOR FROM MANUF. STANDARD
SELECTION
4 EXISTING WALL COVERING AND BASE TO
REMAIN. SEE SHEET A-1A FOR ALTERNATE IF
REQUIRED.
5 QUANTITY OF C-4 CARPET TO BE FIELD
VERIFIED. EXISTING CARPET TO REMAIN AND
PATCH WITH NEW AS REQUIRED BASED ON
FURNITURE RELOCATION.
6 REPLACE WITH NEW WB-2 WALL BASE.
NO
ISSUE
DATE
7 REPAINT EXISTING CONVECTOR COVER P-11.
COLOR: 342
COPPER
INSTALLATION:
QUARTER
TURNED
SIZE: 24" x 24"
CLASS 1
7 STAR RESORTS
880110
CLASS 1
01
FOR BID & PERMIT
11.19.2012
CONTACT: SCOTT CUCCI
PHONE: 1.800.241.4586 x 7949
FINISH SYMBOLS
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
12' - 6" WIDTH.
FLOOR FINISH
C311
1
OFFICE
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-4B_Finish.dwg, 11/20/2012 5:05:55 PM
GENERAL NOTES:
JENNIFER WALL
PHONE: 800-356-9301 x 8288
WB-8
OFFICE
P-10
P-10
NAME
WB-7
NOT USED
B319a
P-10
P-10
MANUFACTURER
NOT USED
1
B318b
COLOR/SIZE
TAG
WALL FINISH
WALL BASE FINISH
P-10
P-10
C-3
NOT USED
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
NOT USED
C343
COUNTER FINISH
OFFICE
P-10
P-10
C331
C312
2
P-10
P-10
OFFICE
OFFICE
T-3
SS-1
C-4
SHAW
CONTRACT
GROUP
STRAIGHTFORWARD TILE
59224
VT-1
P-10
P-10
A330
C332
C330
CONF. RM.
CONF. RM.
OFFICE
CONTACT: MICHAEL MALFI
PHONE: 908-208-0389
CONTACT: MICHAEL MALFI
PHONE: 908-208-0389
DOOR FRAME FINISH
DOOR FINISH
FLOOR TRANSITION
C-5
SHAW
CONTRACT
GROUP
CAMBRIC
5A050
COLOR: LENO
50172
TO MATCH
EXISTING
BROADLOOM
C-6
BENTLEY
PRINCE
STREET
HOLLYWOOD
SEQUEL
BROADLOOM
8HQ32
0630R
COLOR:
GATEWOOD
PARK 801507
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
C-7
BENTLEY
PRINCE
STREET
KINGS ROAD
BROADLOOM
8KR42
0630R
TBD
CONTACT: SUSAN LANE
PHONE: (800) 423-4709 x5213
C313
OFFICE
COLOR:
SORBET
70135
TO MATCH
EXISTING
SIZE: 24" x 24"
P-10
WB-7
C329
C314
OFFICE
OFFICE
C328
OFFICE
C-1
P-2
WB-2
C315
OFFICE
1
C327b
1
OFFICE
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
C316
C327a
OFFICE
OFFICE
1
FINISH PLAN (B)
FINISH PLAN (B)
SCALE: 1/8" = 1'-0"
C326
C325
C324
C323
C322
C321
C320
C319
C318
C317
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
1
A-4B
6 1/4"
6 1/4"
2'-6"
s t u d i o 1 2 0 0, LLC
8
9
8
9
8
10
9
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
10
4
6
CERITFICATE OF AUTHORIZATION # AC-710
10
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
5
7
3
FLOOR PLAN - PANTRY 3
2
FLOOR PLAN - PANTRY 2
SCALE: 1" = 1'-0"
SCALE: 1" = 1'-0"
SCALE: 1" = 1'-0"
P-10
P-10
P-10
PAPER TOWEL
DISPENSER
BOBRICK B-2860
SCHLUTER - JOLLY 1/4" A60 AK
ANODIZED ALUMINUM
OR EQUAL
P-10
EXISTING SOFFIT TO REMAIN
EXISTING SOFFIT TO REMAIN
P-10
PAPER TOWEL DISPENSER
BOBRICK B-2860
PAPER TOWEL DISPENSER
BOBRICK B-2860
ADA BUILDING STANDARD
SINK & FAUCET,
SEE SECTION FOR
MODEL NUMBERS
ADA BUILDING STANDARD
SINK & FAUCET,
SEE SECTION FOR
MODEL NUMBERS
SCHLUTER - JOLLY - 1/4" A60 AK
ANODIZED ALUMINUM
OR EQUAL
WATER DISPENSER BY OWNER
SEE EQUIPMENT SCHEDULE
PROVIDE 1/2" DIA. HOLE FOR
WATERLINE.
SS-3
MICROWAVE BY OWNER
SEE EQUIPMENT SCHEDULE
SS-3
UNDER COUNTER FRIDGE
BY OWNER
SEE EQUIPMENT SCHEDULE
3'-8"
TRASH
WOOD FILLER TO MATCH
CABINETS AS REQUIRED.
PL-2
REF.
2'-10"
PL-2
UNDER COUNTER FRIDGE
(FOREGROUND)
SEE EQUIPMENT SCHEDULE
TRASH
2'-10"
3'-8"
UNDER COUNTER FRIDGE
BY OWNER
SEE EQUIPMENT SCHEDULE
REF.
SS-3
4"
4"
MICROWAVE BY OWNER
SEE EQUIPMENT SCHEDULE
T-3
WATER DISPENSER BY OWNER
SEE EQUIPMENT SCHEDULE
PROVIDE 1/2" DIA. HOLE FOR
WATERLINE.
4"
WATER DISPENSER BY OWNER
SEE EQUIPMENT SCHEDULE
PROVIDE 1/2" DIA. HOLE FOR
WATERLINE.
2'-0"
T-3
2'-0"
T-3
SCHLUTER - JOLLY - 1/4" A60 AK
ANODIZED ALUMINUM
OR EQUAL
2'-0"
EXISTING SOFFIT
TO REMAIN
PL-2
PL-2
REF.
2'-10"
P-10
MICROWAVE BY OWNER
SEE EQUIPMENT SCHEDULE
1
FLOOR PLAN - PANTRY 1
PL-2
NO
01
8
9
8
10
11.19.2012
9
10
2'-0 1/8"
3'-0" HOLD
2'-6"
6
INTERIOR ELEVATIONS - PANTRY 3
1'-6"
3'-6" HOLD
5
INTERIOR ELEVATIONS - PANTRY 2
SCALE: 1" = 1'-0"
2'-1 1/4"
1'-5"
1'-2 1/2"
3'-6" HOLD
1'-5"
4
INTERIOR ELEVATIONS - PANTRY 1
SCALE: 1" = 1'-0"
SCALE: 1" = 1'-0"
P-10
SCHLUTER - JOLLY 1/4" A60 AK
ANODIZED ALUMINUM
OR EQUAL
2'-6"
REFER TO ELEVATIONS
FOR WALL FINISH.
SCALE: 1" = 1'-0"
10
DETAIL @ ADA SINK
SCALE: 1" = 1'-0"
5 1/2" 1 1/2"
4"
PL-2
EQ.
HEAVY DUTY FULL
EXTENSION GLIDES, TYP.
WHITE MELAMINE
INTERIOR (TYP.)
4" PLASTIC LAMINATE TOEKICK.
3"
9
DETAIL @ CABINET DRAWERS
SCALE: 1" = 1'-0"
INTERIOR ELEVATIONS
10
2'-0"
DETAIL @ TRASH BIN
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
REFRIGERATOR
BY OWNER
"OUTWATER" PULLS
MODEL #7030-SC (TYP.)
NOTE: G.C. TO COORDINATE
SINK CLEARANCES WITH MILLWORK.
3"
TRASH
PLASTIC LAMINATE
DRAWER FACES (FULL
OVERLAY).
4"
4"
4"
4"
4" PLASTIC LAMINATE TOEKICK.
PLASTIC LAMINATE
CABINET FRONT
FINISHED PLASTIC
LAMINATE PANEL
BOTH SIDES/ REAR
TO MATCH EXTERIOR
PLASTIC LAMINATE INTERIOR (TYP.)
SCHEDULED COUNTER TOP.
EQ.
1'-11"
2'-4 1/2"
RUBBERMAID COMMERCIAL
WASTE BASKET 2'-6" MAX HEIGHT
GRAY
REFER TO A-0
FOR ACCESSIBILITY
CLEARANCES
2'-10"
PLASTIC LAMINATE CABINETRY
2'-0"
7"
1 1/2"
4"
"OUTWATER" PULLS
MODEL #7030-SC (TYP.)
NOTE:
G.C TO COORDINATE
TRASH BIN CLEARANCE
WITH CABINET
WIDTH & DEPTH
COUNTER TOP. SEE ELEVATIONS
FOR SURFACE MATERIAL AND
FINISH SCHEDULE FOR MORE
INFORMATION.
SS-3
4" BACKSPLASH TO
MATCH COUNTERTOP
EQ.
2'-0"
SCHEDULED COUNTER TOP
W/ 9" DIA. TRASH HOLE
5 1/2" 1 1/2"
1'-11"
4"
2'-0"
4"
4" BACKSPLASH TO
MATCH COUNTERTOP
REFER TO ELEVATIONS
FOR WALL FINISH.
UNDERMOUNT ADA SINK- ELKAY ELUHAD2115 OR EQUAL
& FAUCET - AMERICAN STANDARD 4205.000 OR EQUAL
2'-10"
REFER TO ELEVATIONS
FOR WALL FINISH
T-3
2'-0"
4" BACKSPLASH TO
MATCH COUNTERTOP
2'-10"
1'-6"
9
2'-10"
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-5_Elevations.dwg, 11/20/2012 5:06:12 PM
2'-5 7/8"
8
FOR BID & PERMIT
DATE
PLASTIC LAMINATE
4" TOE KICK,
MATCH CABINETS
PLASTIC LAMINATE
4" TOE KICK,
MATCH CABINETS
PLASTIC LAMINATE
4" TOE KICK,
MATCH CABINETS
ISSUE
1'-11 1/4"
8
1'-5 5/8"
INTERIOR ELEVATIONS - PANTRY 3
SCALE: 1" = 1'-0"
1'-6"
7
A-5
s t u d i o 1 2 0 0, LLC
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
CERITFICATE OF AUTHORIZATION # AC-710
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
BUTT JOINT GLASS
ALIGN
ALIGN TOP OF OPENING
W/EXISTING DOOR
ALIGN TOP OF OPENING
W/EXISTING DOOR
3/8" THICK
TEMPERED GLASS
3/8" THICK
TEMPERED GLASS
3M GLASS FILM FINE CRYSTAL
#SH2FNCR. SUPPLIED AND
INSTALLED BY GC
ALUMINUM FRAME IN TRIMMED
OPENING TO MATCH SIDE LITE
DETAIL.
SCHEDULED BASE
3M GLASS FILM FINE CRYSTAL
#SH2FNCR. APPLY TO
CONFERENCE SIDE OF GLASS.
TOP AND BOTTOM, ALUMINUM
FRAME IN TRIMMED OPENING
TO MATCH EXISTING SIDE LITE
DETAIL.
SCHEDULED BASE
*SEE PLAN FOR AREAS LESS
THAN 3'-0" V.I.F.
INTERIOR ELEVATION - CONFERENCE ROOM A-329
4
INTERIOR ELEVATION - CONFERENCE ROOM A-300
SCALE: 1/2" = 1'-0"
3
INTERIOR ELEVATION - CONFERENCE ROOM A-300
SCALE: 1/2" = 1'-0"
2
3'-0"
INTERIOR ELEVATION - SIDE LIGHT ELEVATION TYP.
SCALE: 1/2" = 1'-0"
1
SCALE: 1/2" = 1'-0"
NO
8"
VARIES
8"
01
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
4'-0"
WALLTALKER ERASE RITE
SEAMLESS HORIZONTAL
INSTALLATION, COLOR
05 OFF WHITE.
WALLTALKER 1" TACK
RAIL TO BE INSTALLED
ON 3 SIDES - COLOR
ACORN #86
WALLTALKER CLEAR SATIN
ANODIZED ALUMINUM
TRAY WITH ALUMINUM
END CAPS
INTERIOR ELEVATION - CONFERENCE ROOM A-330 ENTRANCE
7
SCALE: 1/2" = 1'-0"
2'-8"
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-6_Elevations.dwg, 11/20/2012 5:06:47 PM
HOLD 8 " DISTANCE
FROM LINE OF SOFFIT
OR ADJACENT WALL
INTERIOR ELEVATION - WALLTALKER TYPICAL INSTALLATION
6
SCALE: 1/2" = 1'-0"
SCALE: 1/2" = 1'-0"
BUTT JOINT GLASS
10"
10"
INTERIOR ELEVATION - CONFERENCE ROOM C-300
SCALE: 1/2" = 1'-0"
5
INTERIOR ELEVATION - CONFERENCE ROOM A-330 ENTRANCE
BUTT JOINT GLASS
3/8" THICK
TEMPERED GLASS
3M GLASS FILM FINE CRYSTAL
#SH2FNCR. SUPPLIED AND
INSTALLED BY GC
3/8" THICK
TEMPERED GLASS
3M GLASS FILM FINE CRYSTAL
#SH2FNCR. SUPPLIED AND
INSTALLED BY GC
ALUMINUM FRAME IN TRIMMED
OPENING TO MATCH SIDE LITE
DETAIL.
ALUMINUM FRAME IN TRIMMED
OPENING TO MATCH SIDE LITE
DETAIL.
SCHEDULED BASE
SCHEDULED BASE
10"
10
INTERIOR ELEVATION - CONFERENCE ROOM C-300
SCALE: 1/2" = 1'-0"
10"
9
INTERIOR ELEVATIONS
10"
INTERIOR ELEVATION - CONFERENCE ROOM C-332
SCALE: 1/2" = 1'-0"
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
8
A-6
2'-0"
2
C-7
s t u d i o 1 2 0 0, LLC
511 MILLBURN AVENUE
SHORT HILLS, NJ 07078
973.376.5111
973.376.5011
www.studio1200.com
4
CERITFICATE OF AUTHORIZATION # AC-710
C
Nancy Dougherty, AIA, LEED
NJ-AI 14861/NY-025099/CT-ARI.0011798
2'-0"
2'-0"
P
C-6
1
7
7
1
C-7
3
CONFERENCE ROOM A330 - REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"
3
3
3
2
1'-0"
7
WC-2
WB-8
3
3
1
CONFERENCE ROOM A330 - CONSTRUCTION PLAN - SHOWING FURNITURE & POWER
SCALE: 1/8" = 1'-0"
NO
S:\Avis Budget Group 3rd Flr FFE\5. Drawings & Specifications\5CD- Construction Documents\SHEET FILES\A-7_Conference board room.dwg, 11/20/2012 5:07:04 PM
01
ISSUE
FOR BID & PERMIT
DATE
11.19.2012
KEY NOTES:
1
PROVIDE POWER FOR MOTORIZED WINDOW
SHADES AND CONTROL WIRING FROM NEW
LIGHTING AND SCENE CONTROL SYSTEM.
2
DEMOLISH ALL SWITCHES AND REPLACE WITH NEW
LUTRON SYSTEM TO CONTROL LIGHTS AND WINDOW
TREATMENTS. PROVIDE THREE POSITION PRESET FOR
SUN SHADE AND TWO POSITION CONTROL FOR
BLACK OUT SHADE. LIGHTING TO HAVE 4 PRESET
SCENES.
3
EXISTING CREDENZA TO BE REFINISHED TO MATCH
EXISTING CONFERENCE ROOM TABLE. REMOVE
EXISTING WOOD TOP AND PROVIDE NEW SS-3
COUNTERTOP.
4
LINE OF EXISTING CONFERENCE ROOM TABLE
MODIFY EXISTING
WINDOW POCKET
POCKET AS REQUIRED
FOR FLUSH
INSTALLATION
NEW MECHANICAL
SHADING SYSTEM.
CONTRACTOR
SHALL COORDINATE
SEE FINISH PLAN FOR
SPECIFICAITON.
PROVIDE BLOCKING
AS REQUIRED.
LINE OF COLUMN
BEHIND.
NEW TRACK FOR
BLACK OUT SHADES
INSTALLED AT EACH
SIDE OF OPENING
ALTERATIONS TO:
AVIS BUDGET GROUP
THIRD FLOOR
6 SYLVAN WAY
PARSIPPANY, NJ 07054
EXISTING RADIATOR
TO REMAIN AND
REPAINT WITH P-11.
CONFERENCE ROOM
PLAN, SECTION, AND
ELEVATION DETAILS
EXTERIOR WALL DETAIL AND MECHANICAL SHADING DEVICE
SCALE: 1" = 1'-0"
3
A-7