Residential Controls - LP
Transcription
Residential Controls - LP
Residential Controls 2 Robertshaw Heating Gas Valves - Pilot Models 1 700-204 Hydraulic 700-207 Hydraulic Remote 3/4” None 1/2” 1/2” 1/2” 3/4” None 1/2” 1/2” T E S F 5 6 7 OF 8 None 700-204 1/2” OFF 120 Volt 1/2” ON 700-451 None 3/4” 3/4” S ES PR 720-402 OFF Millivolt Side Outlet With Plug 3 4 Uni-Kit OUT 2 1/2” P I LO PT Step Open Uni-kit T PILO LO 1 700-505 1/2” T 24 Volt 720-406 700-501 3/4” Uni-Kit 720-402 720-474 Straight Thru SE 720-400 Inlet Size Regulator F OF Operator PILOT Part Number ON Combination gas valves feature a manual valve (gas cock), inlet/outlet screens, pilot gas filter, and pilot adjustment key. Safety magnets are slotted for ECO attachment. Uni-kit models have a pressure regulator set for natural gas and include conversion parts for LPGas applications. ON TH TP TH TP Robertshaw Small Capacity Valves - Pilot Models Small capacity gas heating valves are designed for space heaters, recreational vehicles and applications with limited space. All models include a manual valve (gas cock), automatic pilot safety, pilot valve, pilot gas filter and pilot adjusting key. Part Number Operator 710-203 Hydraulic 710-401 24 Volt AC 12 Volt DC 710-501 Millivolt R-3319 Millivolt Operator & Low Mass Dropout Regulator Inlet Size Straight Thru None 1/2” 1/2” Hi-Lo LP 1/2” 3/8” Main Valve Operated by Powerpile R-3319 Safety Operated with Low Mass Thermocouple 700-501 Side Outlet With Plug 1/2” None 710-203 710-501 Safety Operated with Powerpile Jumper 72 NT VE Residential Controls Robertshaw Universal Electronic Gas Valve The 720-079 works equally as well on intermittant pilot, direct spark or hot surface applications. The valve features manual valve, pilot valve (where applicable), dual automatic valves and a main gas pressure regulator all in a small compact body. A pilot plug is included for non-pilot applications. Part Number Inlet Size Straight Thru Side Outlet With Plug Hot Surface or Intermittant Pilot or Direct Spark Uni-Kit 1/2” 3/4” 1/2” 720-079 OF Regulator ON Operator F 720-079 T PILO ESS T PR OU Robertshaw Water Heater Controls 110-285 Shank Length 110-262 1/2” Inverted Flare - RH 160 1/2” FNPT 180 WARNING 1 3/8” 1/2” Inverted Flare - LH READ ALL INSTRUCTIONS BEFORE LIGHTING WARM 1/2” Inverted Flare - RH 1 1/2” 1/2” Inverted Flare - LH ROB E RT Robertshaw Water Heater Controls - Mobile Home 110-203 SH A W O FF For mobile home applications only. Convertible LP/Nat regulator Part Number VACATION 110-280 Outlet HOT 110-265 Inlet N TIO AU 110-262 High Stop OF C Part Number WARNING High Stop OF Inlet Outlet Shank Length 160 1/2 FNPT 1/2” Inverted Flare 1 1/4” 110-203 Robertshaw Add-on Pressure Regulator Kits Type 700 Series (7000) 710 Series (7000 LC) 1751-003 3.5” W.C. Nat X X 1751-004 3.5” W.C. Nat & 11.0” W.C. LP X X 1751-007 Reg Cover Plate X X 1751-013 11.0” W.C. LP X X 1751-016 11.0” W.C. LP X 1751-018 3.5” W.C. Nat X 1751-019 11.0” W.C. LP Step Opening X 1751-024 3.5” W.C. Nat X 1751-025 11.0” W.C. LP X Part Number 720 Series (7200) 73 722 Series (2000) 1751-003 1751-004 1751-013 1751-007 1751-016 1751-018 1751-019 1751-024 1751-025 Residential Controls Robertshaw Electronic Modules Ignition modules feature solid state logic and flame sensing to provide automatic sequencing that will ensure proper operation of gas fired heating systems. Both remote (two rod) and local (one rod) modules are available with various timing sequences to fit spark or hot surface ignition systems. All provide lockout should ignition fail to occur. Universal Spark Pilot Module Part Number 780-002 120 VAC NEUT RAL Sensing Pre-purge Trial Time # Trials Either None 60 sec 3 L2 780- 910 780-910 120 VAC HOT L1 V A L V E Sensing Pre-purge Ignitor Warmup Trial Time # Trials Either 34 sec or less 17 or 34 sec 4 or 7 sec 1 or 3 B U R N E R V A L V E GND J U M P E R HSI FACT ORY MODE FACT ORY PART L: HS845 -34P-I L-4T NO: 100-8 37-00 INPUT = 120 & HSI = 120V, 5A 24 VAC, 60 Hz VALVE = 24V, MAX 1.5A MAX TH CURR ENT = .20 AM + VALVE Universal Hot Surface Module Part Number HSI S E N S E WARNIN G HIGH VOLTAGE PRESENT DISCONN ECT POWER : BEFORE SERVICIN G NOT FIELD REPA IRABL E NOTI CE : LED HEART BEAT 1 FLASH 2 FLASH ES 3 FLASH ES TR 24 V A C STATU S NORMA L OPERAT ION IGNITIO N LOCKOU WEAK FLAME SIGNALT INTERN AL ERROR TR 24 V A C 780-910 Robertshaw Hot Surface Furnace Ignitors High purity silicon carbide ignitors with 17 second warmup. Three models (41-401, 41-402, 41-403) fit majority of hot surface furnaces. Models with no terminal connectors include ceramic wire nuts for universal installation Ceramic Block Style Terminal Connector Type 41-401 A A 41-402 B None C D 41-403 C None 2" 1-1/4" 41-404 C D 41-405 D None 41-406 E None 41-412 F D Part Number 41-405 CERAMIC BLOCK STYLES B A 1-5/8" 41-402 41-401 1-1/4" E F 1-7/8" 1-1/4" 41-404 41-403 TERMINAL CONNECTOR TYPE A D 41-406 41-412 Robertshaw Hot Surface Mini Ignitors The hot surface Mini Ignitors offer a high strength, compact, fast 3 second warmup ignitor for dependable ignition in a myriad of heating systems. 74 Part Number Package 41-603 Ignitor only 41-605 Ignitor with York conversion brackets & wire harness Housing Length 2.5 Residential Controls 24 Volt Wall Thermostats OFF 50 60 70 80 90 10 200-401 Robertshaw Heating 48-68 Sealed Contacts T87K1007 Honeywell Heating 40-90 Solid State Relay T87N1000 Honeywell Heat/Cool 40-90 Solid State Relay Positive Off UH-320 Robertshaw Heating 35-75 Open Contacts Positive Off 50 WHITE-RODGERS 50 50 60 70 80 10 21 32OC 7204 70 7204 200-501 Function Range F White Rodgers Heating 50-90 Robertshaw Heating FA N 80 70 80 90 ON 90 Honeywell Honeywell 60 90 70 80 80 T87N Features O 48-68 90 80 AT T87K Brand 70 B E RT S AW H 200-401 HE 70 Part Number 60 RO 90 60 Millivolt Wall Thermostats 80 90 50-90 70 TO Heating 7204 60 32OC AU White Rogers Open Contacts Positive Off 21 60 Features OF F Range OF COO L Function 60 Brand 90 Part Number Open Contacts Positive Off 35 45 55 65 75 50 60 70 80 90 R Sealed Contacts O B E R T S H A W R TMV Empire Heating 48-86 Sealed Contacts Positive Off OFF TMV UH-320 Transformer Part Number 620-403 Primary Secondary Power Features 120v 24v 40 VA Universal Mount 620-403 765-001 Limit Discs Cut In OF Part Number Part Number Temp Range OF Cut Out OF 3F05-1 90-130 3F05-2 140-180 765-001 90 775-002 140 765-002 110 775-003 150 765-003 120 775-006 180 765-004 130 775-007 190 765-005 140 775-008 200 765-007 160 775-010 230 765-009 180 775-011 250 775-012 300 140 Fan Discs Part Number Adjustable Fan Discs 0 18 0 16 0 17 75 150 3F05-1 Residential Controls Thermocouples 1980-30 Thermocouples generate a thermoelectric current that senses the pilot flame on gas-fired systems. The millivolt output from the thermocouple keeps the electric safety magnet in the gas control open. Q340A1074 Various mounting styles are available to provide secure mounting and proper position at the pilot burner. Length Robertshaw “Snap-Fit” Honeywell Baso “Slim Jim Baso “Husky” 18” 1980-18 Q340A1066 K19AT-18 K16BT-18 24” 1980-24 Q340A1074 K19AT-24 K16BT-24 30” 1980-30 Q340A1082 K19AT-30 K16BT-30 36” 1980-36 Q340A1090 K19AT-36 K16BT-36 48” 1980-48 ----- K19AT-48 K16WT-48 60” 1980-60 ----- ----- ----- 72” 1980-72 ----- ----- ----- Powerpiles Part Number 1950-001 1950-532 1951-001 1951-536 K19AT-24 K16WT-48 750 Millivolt Output Type Two-lead Coaxial With PG9 Length Yes No Coaxial 36” Yes PG9 Adapter No Two-Lead Junction Block Thermocouple TK5-24J 24” Length Junction block provides interruptable connection for remote limit switches etc. Metric Thermocouples Low Mass Thermocouples These thermocouples have metric threads on the control end and double band contruction for clamp style pilot attachment. Used with dual pilot assemblies to facilitate fast drop out of the gas valve main safety. Part Number R-2373 R-237 R-2371 R-1970 Pilot Connection Double Band for Clamp Style Pilots Valve Connection Metric 8M X 1 Length Part Number Pilot Connection Valve Connection 18” R-3473 24” 1960-027 US 7/16-27 Threaded US 11/32-32 Threaded 27” Fast Drop Out Thermocouple Length 18” 27” 750 MV Powerpile 39” 76 Dual Pilot Assy Pilot Assemblies Robertshaw Pilot Assemblies General Pilot All pilot assemblies include a natural gas and propane orifice. Choose bracket style, hood and flame pattern. 1800-100 1830-110 1830-111 Assembly includes natural gas and propane orifice. 1830-112 1810-100 1820-039 1820-029 1830-312 Honeywell Pilot Assemblies Direct Vent Pilot Assemblies All pilot assemblies include a natural gas and propane orifice. Choose bracket style, hood and flame pattern. Q314A4586 Q314A6094 R-2223 Dual Pilot R-2890 R-3466 LP M-151 Gasket R-3623 LP Powerpile (order separately) Two “mirrored” configurations are offered. Pilots have a flat mounting plate for gasketed direct vent use. Select the correct model by comparing the hood and mounting plate orientations. Q314A6102 Fireplace Log Pilots PCA36 Thermocouple Powerpile Electrode (order separately) Metric Direct Vent Pilot Popular metric direct vent pilot. Orifice, electrode, gasket and nuts sold separately. Thermocouple Electrode SIT SD Pilot Baso Pilot Assemblies Gasket All pilot assemblies include a natural gas and propane orifice. Choose bracket style, hood and flame pattern. J999MKA-2 J999MHA-2 J999MYA-2 77 CF-M10-25 M10 X 1 Breakaway Nut M10 X 1 Electrode Nut M10 X 1 Thermocouple Nut Residential Controls Pilot Tubing & Accessories Break-away Fittings Tubing Thread Size Tube Size CF-639 1/8” 1/8” CF-640 3/16” 3/16” Part Number Size (OD) Material Length 1/8” 3/16” Aluminum 1/4” 1/4” CF-641 50 ft. CF-643 Copper 1/4” R-1633 Pilot Tubing Length 5/8” 1/4” 1 1/8” 1/8” CF-M10-25 M10 X 1 1/4” 7/8” Compression Fittings Part Number Nut Ferrule OD Tube Size 61C-2 60C-2 1/8” 61C-3 60C-3 3/16” 61C-4 60C-4 1/4” 4590-817 60C-4 1/4” 61C-4 CF-641 R-1633 CF-M10-25 Metric Full Function Digital Multimeter Used to make closed circuit tests of the thermocouples using a suitable millivolt meter. 10-038 CF-643 4590-817 Long Comp Nut Millivolt Test Block Part Number 60C-4 Function Range DC Volts 400mV, 4V, 40V, 400V, 1000V Use on AC Volts 400mV, 4V, 40V, 400V Thermocouple 50-500 Hz DM383B DIGITAL MULTIMETER R M D ATA HOLD 10-038 750V 40 400uA, 4mA, 40mA, 400mA DC Current MAX 4A OHMS 4M 400K 40K 10A HOLD 40M 400m 4 DCV 40 400 4K 1000 400 750 400 400uA, 4mA, 40mA, 400mA Telescopic Lighter Great for those hard to reach pilots. Alligator clip holds match securely. Extends to 25” and retracts to 5” for handy pocket storage. AC Current 50-500 Hz 10A MAX FUSED ! ACA 500mA FUSED mA A CAT II 1000V CAT III 600V COM V DM383B Thermocouple Testing Use the DC Volts 400m range which provides a best resolution of 0.1 millivolt. 10-038 ADAPTER CONTROL BODY 78 400 4m 40m 10A 10A 4A 400m 400 Ohm, 4K Ohm, 40K Ohm 400K Ohm, 4M Ohm Safety Magnet Check TO MILLIVOLT METER 4A DCA A C A V 400m 400m 4A 40M Ohm BTL-11 4 4m 40m 10A Resistance 40 400 Powerpile Testing Use the DC Volts 4v range which provides a best resolution of 1 millivolt. Orifices Flat Tip Knurled Plug Orifice Part Number Length Threads PO-519 15/32” 1/8” MNPT PO-520 17/32” 1/4” MNPT PO-521 5/8” 3/8 MNPT PO-522 11/16” Bullet Tip Plug Orifice PO-519 PO-501 1/2” MNPT Hex Size Length 1/4” 11/32” 1/4-28 PO-544 5/16” 21/32” 5/16-18 PO-555 3/16” 9/32” PO-516 .136 Round 15/64” PO-560 7/32” .280” 8-32 1/4” 1/4-40 9/16” 1/2-20 PO-532 5/8” 45/64” 5/8-18 PO-534 7/8” 13/16” 3/4-16 5/16-27 3/8-27 PO-501 3/8-24 PO-504 PO-528 PO-530 PO-518 PS-676 OB-205 OB-207 OB-208 Hex Size Barrel Diameter Barrel Length Threads PO-531 3/8” .870” .250” .433” 1/16-27 PO-538 1/2” 1.180” .430” 9/16” .370” 9/16” 1/2” 5/8” 9/16” 3/8” .719” 5/16” PO-523 1/8-27 NPT PO-511 PO-543 3/8” 5/16” 1.058” .360” .433” .937” .500” .318” 1.063” .425” .408” PO-557 7/16-27 PO-537 1/4-18 NPT 3/8” 7/16” 1/2” 5/8” PO-554 PO-558 PO-556 9/16” PO-525 PO-505 79 Threads 6-32 PO-516 10-32 11/32” PO-527 Overall Length 1.115” 1/4” PO-508 Round Barrel Plug Orifice PS-675 1/2-27 PO-509 9/16” PO-510 7/8” 1/4-32 PO-553 PO-505 19/32” 5/16-32 Length 7/16” PO-561 5/8” PO-507 3/8” Hex Size 7/16” Part Number 3/8” Part Number 3/8” PO-542 PO-507 .286-36 3/8” PO-536 Threads PO-512 Threads 11/32” PO-529 Length Flat Tip Hex Plug Orifice 5/16” PO-515 Hex Size PO-533 Chamfered Tip Plug Orifice Part Number Part Number 1/4-28 5/16-24 7/32” 5/16-32 5/16” 11/32-32 7/16” 11/32-27 13/32” 3/8-32 7/16” 1/8 MNPT 3/8” 7/16-27 7/16-24 1/2” 9/16-18 43/64” 1/8-27 7/16” 1/2-24 1/2” 9/16-27 9/16” 1/2-27 19/32” 1/4 MNPT PO-559 11/16” 17/32” 5/8-27 PO-535 7/8” 9/16” 3/4-27 PO-511 Orifices Cap Orifice Part Number Specialty Pilot Orifices Hex Size OverallLength CO-401 .685” CO-400 .725” CO-403 .750” CO-408 1/2” Barrel Diameter .812” Threads 1/8 NPT 3/8-27 .428” CO-402 .725” 3/8-40 CO-406 .812” 3/8-27 CO-409 .815” 3/8-40 CO-405 9/16” .925” .550 Length For Tubing Size SD-4413 11/16” 1/4” CO-400 SD-4413 General Controls Pilot Orifices OverallLength GE-751 1.000” GE-752 1.000” GE-753 .750” GE-754 .875” 1/4” F Comp 5/16-32 GE-757 .225” ---- 8-32 Inlet MI-108 MI-110 .830” 3/16” M Comp 12-28 PS-692 1.125” 3/16” F Comp PS-693 1.140 PS-691 1.125 Part Number OverallLength BA-717 1.000” BA-713 1.375” BA-721 1.000” BA-718 1.250” BA-715 1.750” 1/4” M Comp BA-720 Outlet Retainer Clip Retaining Clip 1/4” F Comp PS-692 PS-693 1/4-28 BA-717 BA-721 1.000” Inlet Outlet 3/16” Breakaway 5/16-32 7/16-27 1/4” Inverted BA-715 7/16-27 BA-716 BA-719 1/8” FNPT 1.125” 1/8” MNPT GE-751 GE-752 GE-757 Part Number Length GR-821 .510” GR-813 .535” GR-803 .500” GR-804 .875” GR-800 .450” GR-801 .332” BA-713 BA-718 5/16-32 1/4” Breakaway Robertshaw Insert Orifices GE-754 Length Outlet BA-716 Adapter Needles Part Number Inlet BA-719 Part Number GE-753 PS-677 PS-677 Penn Baso Pilot Orifices Specialty Metric Insert Part Number OverallLength PS-691 1/2-20 CO-403 CO-408 CO-407 Part Number BA-720 For Tubing Size GR-821 GR-813 GR-803 GR-804 GR-800 GR-801 1/4” Robertshaw Threaded Orifices MI-108 11/16” Part Number GR-820 MI-110 80 Length Inlet Outlet .682” 1/4” M Comp 5/16-24 GR-820 Orifices Honeywell Pilot Orifices Part Number OverallLength MH-850 1.010” MH-854 1.125” MH-855 .812 1/8” FNPT MH-851 1.500” 1/4” Breakaway MH-852 1.250 1/8” FNPT Inlet Honeywell Insert Orifices Part Number Outlet MH-850 MH-856 1/4” Breakaway MH-851 MH-857 MH-858 MH-854 MH-852 OverallLength Inlet 1.875” 1/4” Breakaway WR-904 1.625” 1/8” FNPT WR-905 1.125” X 1.937” 1/4” Compression 1.375” 1/4” Breakaway WR-901 1.125” 1/8” FNPT WR-902 1.250” X 1.125” 1/4” Compression WR-900 WR-900 .437” WR-901 MH-858 MH-855 TL-063 Driving Tool TL-061 TL-062 Outlet Crimper WR-903 Ream Out Hole 7/16-20 TL-064 Narrow Crimper WR-904 Insert Adapter TL-070 Reamer WR-905 1/2-20 Crimp Adapter End MI-100 WR-906 Insert Adapter Completed Installation WR-902 TL-074 Anvil Tapered Broaches Range Part Number Range G-1939 #19 - #39 G-3015 .003” -.013” G-1960 #19 - #60 G-1008 .008” - .017” G-4080 #40 - # 80 G-1010 .010” - .017” G-1012 .012” - .017” G-3020 .003” -.013” 80 Individual Drills MH-857 Orifice Spudding Tools Drills And Drill Sets Part Number MH-856 1/4” Breakaway Handpiece WR-903 WR-906 .375” For Tubing Size 7/16-27 White Rodgers Pilot Orifices Part Number Length G-3015, G-1008, G-1010, G-1012 G-3020 Same as G-3015 but with handle G-4080 81
Similar documents
Fall P artners P ro gram 2012
Humidifier Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Humidifier Solenoid, Universal ����������������������������������������������������� 10 Humidifi...
More information