Artex®system
Transcription
Artex®system
Registration | Articulation Artex®system – the perfect communication between dentist, dental technician and the patient. _ Full system Reliable and fast transfer of patient data from the facebow to the articulator _ Flexible Progressive and modular design of the overall system, an articulator is available for any indication _ Precise High-precision manufacturing in resistant materials ensures the lowest tolerances and appropriate robustness for day-to-day use _ Reliable A reliable, precision-designed system which has proved successful for maximum accuracy Registration | Articulation For maximum accuracy of fit for well-functioning dentures, working with an articulator is essential. The specific challenges are to record the patient’s jaw position quickly and reliably, and to transfer this information precisely and as simply as possible between the dentist and the dental technician. Artex® is renowned worldwide as being fully functional and reliable, and for dentists and dental technicians alike it is an effective aid in recording static jaw relationships and simulating jaw movements. The system‘s modular design means that it can be used for specific requirements, thereby offering maximum flexibility. The Artex®system: for the best possible link-up between dentist and dental technician. For the ultimate in reliability and accuracy. For perfect service to the patient. 02 | 03 system articulator The high-performance, precise and transferable system for simulating jaw movement. Artex®facebow Artex®articulators Artex®Articulators - effective, precise, stable and sensitive movement simulators. Related to everyday practice, reliable and competitively priced - Artex® is known for these qualities worldwide, and with these performance features it ranks amongst the most widely-distributed of articulators. The Artex® range employs a modular design and is geared to responding to the necessary demands. The facebow facilitates patient-analogous working using the articulator, with the articulator taking the place of the patient in simulating movement. For this reason, articulators need to exhibit the same sensitivity as teeth, function accurately and provide maximum stability simultaneously. Artex®transfer stand Splitex calibration Artex®transfer table A key challenge lies in the collaboration between the dentist and the dental technician. What the dental technician manufactures using the articulator needs to work well on the patient. For this, the articulator offers a unique opportunity to understand the patient‘s movements. A reproducible centric position ensures a safe start and end position. Defects smaller than 20 µm can be discovered, checked and corrected using the Artex® articulator. The facebow transfers the patient‘s maxillary position to the articulator, with reference to the cranium axis. Artex®system components + YOUR + POINTS articulator Light, robust, ergonomic and ultra-precise - the Artex®articulator simplifies and accelerates working on the model. Reproducible start-position and end-position of each movement Controllable centric position Receptor-fine simulation of motion High-precision No need to screw in model plates Integrated magnetic model plate system Light, robust and highly ergonomic Carbon material With the aid of this patient-analogous transfer, dentist and dental technician can communicate, conduct analysis and perform checks. Calibrated articulators make it easier to transfer the model from the practice to the laboratory: and dentures constructed using the articulator and checked for function will exhibit identical receptor-fine tactile sense in the patient. This receptor-fine Artex® precision has been impressively confirmed by a scientific study at Tuft’s University in Boston (USA). AT A GLANCE + Full system _ Transfer chain from facebow to articulator _ Fast and reliable transfer of patient data between dental practice and laboratory + System compatible Plenty of space for installing models, including with split-cast bases Generous working space _ Well thought out graduation of articulator types _ System entry can be matched consistently to the profile of requirements + Modular _ Intelligent, modular design of the entire Artex®system _ Can be used for all indications + Precise _ High-precision manufacturing in resistant materials ensures the lowest tolerances and appropriate robustness for day-to-day use + Proven _ System renowned and successful world-wide _ Built on the experience of 25 years in articulator construction The size of the gap between left molar and premolar, frontal view. _ Good frontal view of the working model, in a relaxed, seated position Can be tipped backwards Starting-point for every movement Secure centric position in non-arcon and arcon _ Easy handling and free access to the working models 3 non-tilt positions Scientifically tested precision: all 5 Artex articulators have smaller dimensional deviations than comparable competitors 04 | 05 | 06 Registration | Articulation 07 types Artex® Carbon Technical Data Chart SCI (Sagittal condylar inclination) Bennett-angle (HCI) Registration | Articulation Non-Arcon Design Arcon Design Artex CN Artex CT Artex CP Artex® CR Artex® SL 35° -15° to +60° -20° to +60° -20° to +60° -20° to + 60° ® ® ® 0° to +20° 0° to +20° -5° to +30° -5° to +30° 0° to +30° Protrusion – – – 0 to 6 mm stages from 1 mm to 5 mm Retrusion – – – 0 to 2 mm With SCI inserts (Surtrusion, retrusion, detrusion) ISS (Immediate Sideshift) – – – 0 to 1,5 mm (per side) Integrated in Bennett inserts Distraction – – 0 to 3 mm 0 to 3 mm 0 to 3 mm Centric design Centric click Centric click Centric lever for semi-axes Centric lever for semi-axes Centric slide lock Upper and lower articulator arms prevented from coming apart inadvertently in open centric by: Centric plate Centric plate Arcon clip Arcon clip Transversal slide lock Arbitrary pins for direct transfer with Artex facebow No Yes Yes Yes Yes _Non-Arconbasic model _Arconbasic model Characteristics _Most popular General design features _Integrated magnet system for magnetic retention of models _Lower articulator arm made of lightweight carbon _Anatomical incisal guidance table _Inner working height 126 mm _Three stable working positions (standing on its base/top or lying on its back) _Calibration with the Splitex system _Compatible with the Artex Classic range Order no Artex® Typ CN 217310 Artex® Typ CT 217320 Artex® Typ CP _Universal diagnostic and treatment unit _Ideal for model analysis, splint fabrication and correction 218750 Artex® Typ CR 218760 _Clear condylar assembly _Special SCI and HCI inserts in set 218790 Artex® Typ SL 08 | 09 Artex®system components Registration | Articulation The Artex®system – compatibility without compromise, and high functionality. calibration facebow Using the Splitex® key and Splitex® plate set, all Artex® articulators are calibrated similarly. This magnetic plate system serves as a metrical aid to calibrate different articulators. The precision of calibration is such that deviations are brought down to below 20 µm. This means that models can be mounted and changed with precision on any calibrated Artex®. The Artex® facebow is not just a success on account of its ease of handling, but also makes it possible to work rapidly and economically: in just two minutes, the cranium/axis relation is determined in corresponding to the patient‘s anatomy. Additionally, the ability to calibrate the Artex® articulators simplifies the process of transferring the model from the practice to the laboratory. Where both parties have a calibrated articulator, then only the models need to be transported, and not the complete articulator. Not only does this protect the articulator against handling problems, it also saves on postal charges. In functional diagnostics and treatment, it is an indispensable tool which considerably reduces grinding time at chairside. It can also be used for electronic registration as a standard facebow with Cadiax® compact. Splitex plate set for Carbon version Artex facebow _ Scientifically proven: Artex® articulators can be calibrated to a standardization with tolerances < 10 µm _ Splitex® counter plates prevent the risk of poor fit caused by plaster expansion and guarantee quick, precise adaptation to Splitex® metal plates Splitex keys Splitex counter-plates in black or white _ Cranium/axis relation determined in corresponding to the patient‘s anatomy in just two minutes _ Quick and secure the 3-D universal joint _ Cranium-axis oriented transfer of maxillary model to the articulator transfers the real jaw position precisely to the articulator and consequently reduces grinding time at the chairside _ Reliable reproducibility of arbitrary axis position using cushioned Leipzig Nasion + Leipzig Nasion 10 | 11 + Registration | Articulation transfer stand For optimally safe transport of patient data, the universal joint with bite fork is removed from the facebow and inserted into the transfer stand. There, the bite fork is fixed in plaster and then separated from the universal support. Now all the information is located securely and permanently on the removable transfer table, and can be safely transported. _ Saves time and plaster working at the dental practice, and ensures safe transport to the laboratory _ Saves on procurement of multiple facebows _ Saves time on mounting the maxillary model _ Simplest system on the market for transferring the facebow record from the dental practice to the laboratory + Splitex transfer stand Splitex transfer table Transfer stand Transfer table Mounting articulator 12 | 13 Accessories Accessories Artex®/Splitex® mounting articulator The mounting articulator is not used as an articulator, but can be understood as a device which protects this precision instrument. Since models can be freely exchanged between similarly-calibrated articulators, they do not need to be transported in the articulator but can be transferred using mounting articulators which are similarly calibrated to the same model settings. _ Safeguards articulators against water and plaster dirt _ Compatible with all types of facebow and transfer systems _ Centric and vertical height are fixed using rigid hinge axis/incisal pins _ Easy removal of the models due to a detachable magnet in the upper frame ! 217586 217589 217341 218160 217586C 217589C 218141 218142 217585 218140 217340 217585C @ 218162 218110C 218180 217345 218150 218170C 217260 217131 Artex® set-up index key for the mandible Fundamental scale for average-value alignment of the endentulous mandible model at the symphysis and retromolar pads Artex® set-up templates Guide for set-up of full dentures according to the Spee/ Wilson occlusion curve. The horizontally and vertically adjustable device with occlusal plane indicator and adjustable inclination supports the different templates. _ Flat template for average-value mounting of dentulous models _ 4 radius for adjustment to different tooth/set-up concepts _ Screw or magnet version, to be ordered separately or as a set Dr. Behrend type clinometer Adjustable Perspex® shield furnished with several vertical lines and two horizontal lines, for transferring physiognomic esthetic parameters. Once adjusted to the facebow, the horizontal lines can be aligned to match the eyes and the line of the anterior teeth, using the rotary control. The tooth position as determined is represented as an angle, and can be transferred to the articulator in the laboratory to recreate the position of the anterior teeth. _ Determines asymmetries and compensates them during set-up _ Supplies the technician with important esthetic information _ Helps to prevent remakes, improves function and esthetics Artex® anterior guidance Special accessory which fits in all Artex articulators, to mechanically individualize/program the anterior area. _ Micrometer pin to exactly raise/lower the anterior guidance in steps of 1/10 mm _ Individual anterior guidance using radially guided pin with infinitely variable table plate (protrusion 0-40 °, laterotrusion 0-70 °, turning to right and left) _ Cranked pin provides for unhindered access during anterior set-up and maintains clear sightlines Artex® set-up index key for the maxilla This facilitates average-value alignment of the endentulous maxilla at the remaining anatomical fold in the throat. The vertical adjustment of the support fork and the reciprocal bar facilitate improved individual positioning of the model. _ Semi-individual positioning in the articulator without facebow _ Basic version with screw thread, or conversion plate for the Splitex system Registration | Articulation Technical information: Dimensions: 67 x 35 x 46 mm, weight: 157 g Artex® Noplast Artex® Noplast facilitates rapid mechanical plaster-free model fixing. The freely moveable model plate safely holds the models in place, using the conventional method with a model table. With the help of female threaded screws, the joint discs avoid strain and distortion. _ Time-saving interim solution for model analysis and discussion _ For the making of individual trays, templates and for orthodontic apparatuses _ To check the function of CoCr cases on investment models _ Recommended only for interim work and allows working articulators to be used for main, definitive work, thus, saving on costs 14 | 15 Ordering information Registration | Articulation Artex® Type CN 217310 Artex Type CN Artex® Type CT 217320 Artex Type CT Artex® Type CP 218750 Artex Type CP Artex® Type CR 218760 Artex Type CR Artex® Type SL 218790 Artex® Type SL 217330 217331 215250 ^ $ ! @ & 217589 217341 218160 217586C 217589C 218141 218142 Modell plate blue (pair) Modell plate blue, 50 pcs. Retention Disks, 100 pcs. 217585 Splitex® 216010C Splitex key for Artex, 126 mm, Carbon-Version 216011 Splitex Spacer Plate +10 mm 216100C ! – ^ Splitex-Plate Set, Carbon-Version 216150 $ Retention Disks, 100 pcs. 216230 & Splitex-Counter Plate, 10 pcs. Premium white 216235 # 217586 Splitex-Counter plates 100 pcs. Classic black 218140 217340 217585C 218162 218110C 217131 218180 217345 218150 217260 218170C Artex®Setup index key for the maxilla 216255C incl. thread (Thread version) for Carbon-Version 216180 SplitexAlteration plate Artex®Anterior Guidance 217585C Anterior guidance pin for Carbon-Version 218170C Individ. anterior guidance, 0 – 70° protrusion, 0 – 40° laterotrusion pin, table, adjusting bolt for Carbon-Version 217260 Artex Incisal needle 217340 Plate anatomical for Carbon-Version 217345 Plate 0° for Carbon-Version 218110C Pin holder 217131 Cranked pin for Artex 218180 Micrometer pin ! Artex®mandibular index key 217700C ! 126 mm for Carbon-Version 216250C index key with Splitex, 126 mm for Carbon-Version % Artex®Setup Templates 217730C Template holder, thread for Carbon-Version 217740 Template flat 217741 Template R100 217742 Template R125 217744 Template R140 217746 Template R160 217749C Setup Templates, 6 pcs. for Carbon-Version 216260C Template holder with Splitex, 126 mm for Carbon-Version 216269C dito, with Template-Set 5 pcs. for Carbon-Version ® @ # Artex -Facebow 218600 ! – % 218620 ! Joint Support 218680 @ Leipzig Nasion 218607 # Porus Buttons „Standard“, pair 217650 $ Artex Quickbite, 10 pcs. 217928 % Tray Handle Optional accessory: $ ! % Artex® -Transfer Stand 218670C with table for Carbon-Version 216240 Splitex Transfer Stand complete Artex® -Transfer Table 217671C Carbon-Version 216270 Splitex-Version 218609 218610 218635 218690 217650 Porus Buttons long, pair Axis-plane Pointer w. screw Carrier for Facebow Cadiax compact, pair Nasion vertically adjustab. Artex-Quickbite, 10 pcs. Artex®Noplast 217480C Noplast for Artex Carbon-Version Artex® /Splitex® Mounting Articulator 216020C Splitex Mounting Dentist Mini Kit: Artex Facebow, Splitex Transfer Stand 218600 Artex Facebow 216240 Splitex Transfer Stand Articulator, 126 mm Carbon-Version Clinometer 219960C ! „Laboratory“ Clinometer @ „Operatory“ Clinometer 218110C Pin holder 217131 Cranked pin for Artex 219950 Dentist Kit: Free choosable Artex articulator, Splitex Plate Set, Artex Facebow, Splitex Transfer Stand 217310, 217320, 218750, 218760, 218790 Artex (CN, CT, CP, CR or SL) 216100C Splitex Plate Set 218600 Artex Facebow 216240 Splitex Transfer Stand Technician Kit: Free choosable Artex articulator, Splitex Plate Set, Counter Plates, Retention Disk, Splitex Key 217310, 217320, 218750, 218760, 218790 Artex (CN, CT, CP, CR or SL) 216100C Splitex Plate Set 216235 Counter Plates 216150 Retention Disks 216010C Splitex key 16 | 17 921717GB 0307 www.hellblau.com Amann Girrbach GmbH Herrschaftswiesen 1 6842 Koblach | Austria Fon +43 5523 62333-0 Fax +43 5523 55990 [email protected] www.amanngirrbach.com