potbelly sandwich shop

Transcription

potbelly sandwich shop
Sheet List Table
LEGENDS NOTES & ABBREVIATIONS
A0.2
EGRESS PLAN
A1.0
PENETRATION &TRENCHING PLAN
A1.1
CONSTRUCTION PLAN
A1.1a
ENLARGED SERVICE LINE PLAN
LANDLORD:
A1.2
REFLECTED CEILING PLAN
CORPORATE OFFICE PROPERTIES TRUST
6711 COLUMBIA GATEWAY DRIVE, SUITE 300
COLUMBIA, MD 21046
CONTACT: ANDREW WELKER
PH: 443-285-5668
EMAIL: [email protected]
A1.3
FLOOR FINISH PLAN
A1.4
FURNITURE FIXTURE AND EQUIPMENT PLAN
A1.5
CASEWORK PLAN
A1.6
ENLARGED TOILET ROOM PLANS & DETAILS
A2.0
DOOR SCHEDULES & DETAILS
A2.1
FINISH SCHEDULE
A2.2
FINISH SCHEDULE (CONT.)
A2.3
FURNITURE FIXTURE & EQUIPMENT SCHEDULES
A2.4
FURNITURE FIXTURE & EQUIPMENT SCHEDULES (CONT.)
A2.5
PLUMBING SCHEDULE
A2.6
LIGHTING SCHEDULE
A2.7
CASEWORK SCHEDULE
A2.8
CASEWORK SCHEDULE (CONT.)
A2.9
CASEWORK SCHEDULE (CONT.)
A3.0
EXTERIOR ELEVATIONS
A4.0
INTERIOR ELEVATIONS
A4.1
INTERIOR ELEVATIONS
A4.2
INTERIOR ELEVATIONS
A4.3
INTERIOR ELEVATIONS
A4.4
INTERIOR ELEVATIONS
A4.5
INTERIOR ELEVATIONS
A5.0
INTERIOR DETAILS
A5.1
INTERIOR DETAILS
A5.2
INTERIOR DETAILS
A5.3
INTERIOR DETAILS
A5.4
INTERIOR DETAILS
AS1.0
ARCHITECTURAL SPECIFICATIONS
AS1.1
ARCHITECTURAL SPECIFICATIONS
AS1.2
ARCHITECTURAL SPECIFICATIONS
AS1.3
ARCHITECTURAL SPECIFICATIONS
AS1.4
ARCHITECTURAL SPECIFICATIONS
S1.0
ROOF FRAMING PLAN GENERAL NOTES
M1.0
MECHANICAL LEGEND AND NOTES
M2.0
MECHANICAL PLAN
M3.0
MECHANICAL SCHEDULES
M4.0
MECHANICAL DETAILS
M5.0
MECHANICAL ROOF PLAN
M6.0
EXHAUST HOOD DRAWINGS
P1.0
PLUMBING LEGEND AND NOTES
P2.0
PLUMBING SUPPLY AND SCHEDULES
P3.0
PLUMBING WASTE PLAN
P4.0
PLUMBING SCHEDULE
P5.0
PLUMBING RISERS
P6.0
PLUMBING DETAILS
E1.0
ELECTRICAL LEGEND AND NOTES
E2.0
POWER PLAN
E3.0
LIGHTING PLAN
E4.0
SYSTEMS PLAN
E5.0
LIGHTING SCHEDULE
E6.0
ELECTRICAL PANEL SCHEDULES
E7.0
ELECTRICAL DETAILS
PROJECT CONTACTS
SITE VICINITY MAP
CLIENT / OWNER PROJECT MGR:
POTBELLY SANDWICH WORKS, INC.
PROJECT
LOCATION
NORTH
111 N. CANAL, SUITE 850
CHICAGO, ILLINOIS 60606
DESIGN MNGR: CASSIE BURTON
PH: 312-475-3847
EMAIL: [email protected]
CONSTRUCTION MNGR: PAULA OLDHAM
PH: 774-270-6995
ARCHITECT:
MEP ENGINEER:
DXU, LLC
404 S. WELLS STREET, SUITE 300
CHICAGO, IL 60607
CONTACT: ANTHONY VOLPE
PH: 312-955-0334 X 101
EMAIL: [email protected]
AEDIFICA CASE ENGINEERING
782 MERUS COURT
FENTON, MO 63026
SITE KEY PLAN
A
APPLICABLE CODES
AREA
OF WORK
BUILDING CODE:
PLUMBING CODE:
MECHANICAL CODE:
ELECTRICAL CODE:
ENERGY CODE:
FIRE CODE:
ACCESSIBILITY CODE:
2012 INTERNATIONAL BUILDING CODE
2012 INTERNATIONAL PLUMBING CODE
2012 INTERNATIONAL MECHANICAL CODE
2011 NATIONAL ELECTRICAL CODE
2012 INTERNATIONAL ENERGY CONSERVATION CODE
2012 NATIONAL FIRE PROTECTION ASSOCIATION
MARYLAND ACCESSIBILITY CODE
SITE INFORMATION/OCCUPANCY
BUILDING DESCRIPTION:
PROJECT DESCRIPTION:
NORTH
COMMERCIAL TENANT IMPROVEMENTS TO EXISTING
BUILDING
W1
IIB
A-2
RESTAURANT
2,320 SQ.FT.
1
33'-8" APPROX.
ZONING:
CONSTRUCTION TYPE:
OCCUPANCY CLASSIFICATION:
USE GROUP:
AREA OF CONSTRUCTION:
# OF STORIES:
BUILDING HEIGHT:
ROOM
DINING FIXED
SERVICE/PREP
AREA (SF)
1,193 SQ. FT.
669 SQ. FT.
# FIXTURES REQUIRED:
MEN:
WOMEN:
SERVICE SINK: DRINKING
FOUNTAIN:
# OF FIXTURES PROVIDED:
MEN:
WOMEN:
SERVICE SINK:
DRINKING FOUNTAIN:
OCCUPANCY
1,193/15=80
669/200=3
TOTAL OCCUPANT LOAD:
TOTAL # OF SEATS:
83
49 (INTERIOR)
12 (EXTERIOR)
1 WC, 1 LAV
1 WC, 1 LAV
1
1
1 WC, 1 LAV
1 WC, 1 LAV
1
WATER SERVICE IS PROVIDED DIRECTLY TO CUSTOMER
REQUIRED EGRESS WIDTH:
COMMON PATH OF EGRESS:
MAXIMUM EXIT TRAVEL DISTANCE:
# EXITS REQUIRED:
# EXITS PROVIDED:
44"
75'
250' (W/SPRINKLER SYSTEM)
2
2
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
COVER AND
GENERAL
INFORMATION
SHEET NUMBER
A0.0
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.0 COVER & GENERAL INFORMATION.DWG
A0.1
JYOU
COVER & GENERAL INFORMATION
5/23/2016 10:28:57 AM
A0.0
PROJECT NUMBER: 16-059
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
Sheet Title
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
POTBELLY SANDWICH SHOP
Sheet
Number
FP
FLR
FRA
FT
FV
GA
GALV
GC
GRND
GWB
HC
HD
HDR
HDWD
HDWR
HM
HORZ
HR
HT
HVAC
HW
ID
IF
IG
INSUL
MFG
MIN
NAT
NIC
NL
NSF
NTS
OA
OC
OD
OF
OFI
OPNG
OPP
PC
PERP
PLAM
PLEX
PLYWD
PM
POC
POS
PSW
PSW-HUB
PSW-CS
PT
QT
R
RECEPT
REF
REFRIG
REQ('D)
REV
RND
RO
SC
SF
SHT
SHT MTL
SIM
SOL
SPEC
SQ
ST
SS
STG
STRUCT
STL
SUSP
SW
T&G
TEL
TEMP
TYP
UC
UNO
V
VAL
VCT
VD
VERT
VIF
WD
WH
XFMR
ELEVATION TAG
TOP = ELEVATION NUMBER
BOTTOM = SHEET NUMBER
1
A0.1
1.
DETAIL TAG
TOP = ELEVATION NUMBER
BOTTOM = SHEET NUMBER
SECTION TAG
TOP = ELEVATION NUMBER
BOTTOM = SHEET NUMBER
1
101
2.
REVISION CLOUD / TAG
NUMBER DENOTES NUMBER OF ADDENDUMS
TRUE NORTH
SHOWS DIRECTION OF MAGNETIC NORTH
PLAN NORTH
AS REFERENCED TO IN ALL DRAWINGS CONTAINED
IN THIS SET
NORTH
HEIGHT
DATUM
3.
##
DOOR TAG
NUMBER DENOTES DOOR REFERENCE TO DOOR SCHEDULE
D####
WINDOW TAG
LETTER DENOTES WINDOW REFERENCE
#
FURNITURE / ACCESSORY / CASEWORK / EQUIPMENT /
SIGNAGE TAG
NUMBER DENOTES REFERENCE TO FURNITURE &
ACCESSORIES SCHEDULE
X###
FINISH TAG
NUMBER DENOTES INTERIOR FINISH MATERIAL, REFER TO
FINISH SCHEDULE
L-3
AFF HEIGHT TAGS
HEIGHT ABOVE FINISHED FLOOR
X'-X" AFF
WALL TYPE TAG
LETTER DENOTES WALL TYPE
X
WALL BLOCKING TAG
LETTER DENOTES WALL BLOCKING LOCATION
X
5.
G.C. TO COORDINATE LAYOUT, ROUTING, AND INSTALLATION OF ALL NEW MECHANICAL, ELECTRICAL, FIRE
PROTECTION, AND PLUMBING WORK WITH EXISTING MEP/FP SYSTEMS, AND WITH EXISTING STRUCTURE TO
REMAIN. REPORT ALL DISCREPANCIES TO OWNER'S REP IN WRITING PRIOR TO SUBMITTING BID PACKAGE.
6.
EACH CONTRACTOR OR SUBCONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, AND LICENSES
REQUIRED FOR PROPER EXECUTION OF THEIR PORTION OF THE WORK. THIS EXCLUDES MAIN BUILDING
PERMITS, BUSINESS & HEALTH LICENSES.
7.
EACH CONTRACTOR OR SUBCONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF ALL APPLICABLE LAWS
AND ORDER OF PUBLIC OFFICIALS WITH JURISDICTION FOR SAFETY OF PERSONS/PROPERTY.
8.
ALL WORK SHALL BE DONE BY LICENSED CONTRACTORS AND IN CONFORMANCE WITH ALL NATIONAL, STATE,
COUNTY, AND LOCAL CODES. ANY VARIANCE/NON-COMPLIANCE WITH LOCAL CODE TO BE REPORTED TO
OWNER'S REP IN WRITING PRIOR TO BIDS.
0
1'
2'
GRAPHIC SCALE
DENOTES SCALE OF DRAWING
GC TO INSTALL ALL OWNER PROVIDED DECOR ITEMS AS SHOWN IN DECOR PACKAGE TO BE FORTHCOMING,
INCLUDING ALL MENU BOARDS AND MARKETING SIGNAGE.
2.
POTBELLY WILL PROVIDE WITH DECOR PACKAGE:
A. PLYWOOD MENU BACKERS
D. BLACK METAL BRACKETS WITH SET SCREWS TO HOLD PIPE
E. SOUP/SHAKE MENU BOARDS
F. DESSERT MENU BOARD
G. ALL FRAMED DECOR ITEMS AND KNICK KNACKS
3.
GC WILL NEED TO SUPPLY:
A. 2 21" 16 GAUGE FINISH NAILS FOR ALL PICTURE FRAME DECOR PIECES
B. PLASTIC ANCHORS TO BE USED AT BRICK AND 2-4 SCREWS PER FRAME
DEPENDING UPON SIZE, USE MORE IF LARGER THAN 24" X 36".
C. CLEAR LIQUID NAILS
D. MISCELLANEOUS FASTENERS AND HANGING HARDWARE INCLUDING BUT NOT LIMITED TO:
4.
GENERAL DECOR INSTALLATION INSTRUCTIONS:
A. ALL PICTURE FRAMES ARE NAILED TO THE WALL WITH NAIL GUN. USE MINIMUM OF 4 NAILS PER
PIECE.
B. PLATES TO BE SET ON LEDGES, GLUED ON TOP AND BOTTOM WITH CLEAR LIQUID NAILS.
C. ALL KNICK KNACKS TO BE GLUED DOWN WITH CLEAR LIQUID NAILS.
D. HAND WASHING SIGNS TO BE AFIXED TO WALL NEAR PAPER TOWEL DISPENSERS WITH DOUBLE
STICK TAPE (PROVIDED ON BACK OF SIGN).
E. DO NOT USE LIQUID NAILS TO ATTACH ARTWORK TO WALLS UNLESS UNABLE TO NAIL DIRECTLY.
5.
MAIN MENU BOARD INSTALLATION INSTRUCTIONS:
A.
G.C. & ALL SUBS TO FAMILIARIZE THEMSELVES WITH THE BASE BUILDING AND TO VERIFY WITH LANDLORD
BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO BASE BUILDING.
EDGE.
11.
G.C. ASSUMES COMPLETE RESPONSIBILITY WHEN OWNER FURNISHED ITEMS ARE ACCEPTED AND RECEIVED
BY G.C.
12.
G.C. TO ENSURE THAT A COMPLETE SET OF CONSTRUCTION DOCUMENTS IS GIVEN TO ALL
SUBCONTRACTORS PRIOR TO BID SUBMISSION.
13.
DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS TAKE PRECEDENT. IN CASE OF DISCREPANCIES OR
CONFLICTS, NOTIFY OWNER'S REP IMMEDIATELY. ALL DIMENSIONS ARE FROM FACE OF FINISH SURFACE TO
FACE OF FINISH SURFACE UNLESS OTHERWISE NOTED.
14.
ALL WOOD IN CONTACT WITH CONCRETE AND AT EXTERIOR LOCATIONS MUST BE PRESSURE TREATED
MOISTURE RESISTANT WOOD.
F. IF THE MENU WILL BE HANGING FROM THE CEILING: THE PIPE WILL BE SUPPLIED WITH TWO EYE
BOLTS ATTACHED. USE THE PROPER HARDWARE FOR ANCHORING INTO THE CEILING OR
15.
ALL WALL CONSTRUCTION FACING PLUMBING FIXTURE AREAS MUST UTILIZE MOISTURE RESISTANT GYPSUM
BOARD UNLESS OTHERWISE NOTED.
16.
G.C. TO FILL AND STAIN ALL NAIL HOLES.
CEILING OR STRUCTURAL JOIST TO THE EYE BOLTS IN THE PIPE.
G. WHEN THE PIPE IS SECURE, HANG THE ASSEMBLED MENU PANELS IN THE ORDER INDICATED IN
INSTALL GUIDE IN CONSTRUCTION BINDER.
17.
G.C. TO CAULK ALL BASE AND CHAIR RAIL TO DISSIMILAR MATERIALS.
18.
G.C. TO PROVIDE AS BUILT DRAWINGS (CONSISTING OF REDLINED CONSTRUCTION DRAWINGS) TO OWNER'S
REP WITHIN TWO WEEKS OF COMPLETION OF PROJECT, PRIOR TO FINAL PAYMENT.
19.
G.C. TO COVER WINDOWS AS REQUIRED, DURING CONSTRUCTION WITH CRAFT PAPER TO 10 FT. CONFIRM
WITH CENTER RULES & REGULATIONS.
THE BRACKETS OVER THE PILOT HOLES. THIS WILL ALSO ALLOW FOR ADJUSTMENT LATER IF THE
MENU PANELS ARE NOT HANGING SQUARE TO THE PIPE WHEN FINISHED.
C. TAKE 1 CARRIAGE BOLT AND 1 WING NUT FROM THE BAG AND BOLT THE BAG WITH THE REST
OF THE HARDWARE TO ONE OF THE PLYWOOD PANELS FOR THE OPERATIONS TEAM TO USE
LATER FOR ATTACHING THE MENU PANELS.
D. IF THE MENU REQUIRES A STANDARD WALL MOUNT WITH BRACKETS: MOUNT THE BRACKETS
WITH SCREWS AND/OR ANCHORS IN THE SPECIFIED LOCATION, MAKING SURE TO LEAVE AT LEAST
E. NUMBER OF BRACKETS REQUIRED PER MENU:
6.
22. INSTALLATION & FINISHING OF WOOD FLOORING, CONCRETE STAIN AND KITCHEN PAINT TO BE BID AS NIGHT
WORK.
23.
24.
25.
ALL LIGHT SWITCHES, THERMOSTATS, SECURITY ALARMS, ELECTRICAL OUTLETS, ETC. MUST BE MOUNTED
TO MEET ALL GOVERNING ACCESSIBILITY REQUIREMENTS FOR FLOOR & HEIGHT CLEARANCES AND ONE
HAND GRASPING OPERATION.
FLAME SPREAD RATINGS FOR INSULATION AND FINISHES:
A. ALL CONCEALED BATT & BLANKET INSULATION TO BE USED IN THE WALL AND ATTIC IS TO BE CLASS A
OR BETTER, FLAME SPREAD 25 OR LESS & A SMOKE-DEVELOPED RATING OF 450 OR LESS WHEN TESTED IN
ACCORDANCE WITH ASTM E84.
B. ALL WALL & CEILING FINISHES TO BE CLASS B OR BETTER, FLAME SPREAD 26-75 WITH MAXIMUM SMOKE
DEVELOPED OF 450 OR LESS WHEN TESTED IN ACCORDANCE WITH ASTM E84.
C. ALL INTERIOR TRIM TO BE CLASS 2, FLAME SPREAD 76-200 WITH MAXIMUM SMOKE DEVELOPED OF 450.
ALL DECORATIVE MATERIALS SHALL BE NONCOMBUSTIBLE OR MAINTAIN FLAME RESISTANCE IN
ACCORDANCE WITH SECTION 807.2
D. FLOOR COVERINGS TO HAVE A FLAME SPREAD RATING NOT TO EXCEED 75.
ALL COMBUSTIBLE INTERIOR FINISH & TRIM ITEMS ARE TO BE APPLIED DIRECTLY TO A NON-COMBUSTIBLE
BASE.
26. PROVIDE AND INSTALL OCCUPANCY SIGN IN A CONSPICUOUS LOCATION IN ACCORDANCE WITH STATE &
LOCAL CODES.
27. IF THE LANDLORD OR BUILDING REPRESENTATIVE REQUIRES X-RAYING OF FLOOR, ALL COSTS SHALL BE
INCLUDED IN THE GENERAL CONTRACTOR'S ORIGINAL BID.
28. G.C SHALL VERIFY THE LOCATION OF ALL UTILITIES.
SOUP/SHAKE MENU BOARD INSTALLATION INSTRUCTIONS:
A. INSTALL PLASTIC WALL ANCHORS AND #10 SCREWS IN THE DRYWALL, CENTERED AND
SPACED TO MATCH THE DISTANCE BETWEEN THE D-RING HANGERS IN THE BACK OF THE
MENUS. LEAVE THE SCREW HEADS FAR ENOUGH AWAY FROM THE WALL TO CATCH THE
D-RING HANGERS AND MAKE SURE THE MENU IS HANGING FLAT AGAINST THE WALL.
7.
DESSERT MENU INSTALLATION INSTRUCTIONS:
A. CENTER MENU FRAME OVER ICE CREAM CABINET IN BOTH WIDTH AND HEIGHT OR AS PER
PSW REP DIRECTION.
B. NAIL TO WALL WITH NAIL GUN USING MINIMUM 8 NAILS.
C. PLACE CHALKBOARD PANEL ON HOOKS IN CENTER OF MENU FRAME.
D. TOUCH UP NAIL HOLES/BLEMISHES AS NEEDED ON MENU FRAME WITH TOUCH UP PAINT.
8.
A-FRAME TOPPER INSTALLATION INSTRUCTIONS:
A. REMOVE BOTH EXISTING BLACK FRAMES THAT HOLD THE CHALKBOARDS AND PRINTED
20. KEEP DRIVEWAYS AND ENTRANCES CLEAR AT ALL TIMES. EACH SUBCONTRACTOR SHALL REMOVE RUBBISH
AT THE COMPLETION OF HIS WORK. PROMPTLY REPAIR ANY DAMAGE DONE TO ADJACENT
PROPERTY/TENANT SPACES AT NOT COST TO OWNER.
TWO (2) FIRE EXTINGUISHERS TO BE SUPPLIED BY OWNER, LOCATED BY FIRE MARSHAL, INSTALLED BY G.C.
FIRE EXTINGUISHERS: LARSON #MP5 WITH UL RATING OF 2A-10B:C
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
R
955
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
HANGING APPLICATION FOR MENU BOARDS)
WELDED-LINK CHAIN, CUT TO SIZE ON SITE (IF HANGING APPLICATION FOR MENU BOARDS)
G.C SHALL VERIFY ALL EQUIPMENT, MILLWORK, AND OTHER ITEMS BEING FURNISHED BY OWNER OR
OWNER'S CONTRACTORS FOR WHICH G.C IS RESPONSIBLE FOR INSTALLING ARE IN GOOD CONDITION.
21.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
C. BOX OF HARDWARE WITH QUANTITIES SPECIFIC TO MENU SIZE INCLUDING:
10.
S
S
REFER TO FURNISHINGS, FIXTURE & EQUIPMENT SHEET FOR ALL EQUIPMENT LOCATIONS. REFER TO
EQUIPMENT MANUAL & ENGINEERING DWGS. FOR EQUIPMENT REQUIREMENTS. NOTIFY OWNER'S REP OF
ANY DISCREPANCIES.
G.C. TO COMPLY WITH LANDLORD'S AND OWNER'S RULES AND REGULATIONS REGARDING CONSTRUCTION
WITHIN THE BUILDING. GC & ALL SUBCONTRACTORS SHALL FAMILIARIZE THEMSELVES WITH THE BASE
BUILDING AND TO VERIFY WITH THE LANDLORD BEFORE MODIFYING OR ATTACHING NEW CONSTRUCTION TO
BASE BUILDING. GC SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER
SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE COURSE OF THE WORK.
9.
1.
ALL EXISTING CONDITIONS, STRUCTURAL AND MECHANICAL CONNECTIONS TO ALL EXISTING BUILDING
SERVICES MUST BE FIELD VERIFIED PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES SHALL BE
REFLECTED AND NO ADJUSTMENT TO BID PRICE SHALL BE MADE AFTER BID SUBMISSION. SUBMISSION OF
BID SHALL BE UNDERSTOOD AND CONSTRUED AS CONTRACTOR HAVING VERIFIED ALL EXISTING CONDITION.
WHETHER OR NOT SHOWN ON DRAWINGS AND HAVING TAKEN INTO ACCOUNT ANY ADJUSTMENT
NECESSARY TO FULFILL THE DESIGN INTENT IN FULL AND COMPLETELY.
4.
ELEVATION BENCHMARK
KEY NOTE
NUMBER DENOTES REFERENCE TO KEY NOTES ON
SPECIFIED SHEET
GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL SITE
CONDITIONS PERTAINING TO THIS PROJECT PRIOR TO SUBMISSION OF BIDS. ANY DISCREPANCIES FOUND
DURING SITE INVESTIGATION TO BE REPORTED TO OWNER'S REP IN WRITING PRIOR TO BID SUBMISSION.
G.C. TO ENSURE THAT EXISTING STRUCTURE IS NOT ALTERED OR DAMAGED WITH EXCEPTION OF
MODIFICATIONS SHOWN ON DRAWINGS. ALL INSTALLATIONS AND ALL CONNECTIONS TO EXISTING BUILDING
MECHANICAL SYSTEMS SHALL BE COORDINATED WITH AND PERFORMED UNDER THE SUPERVISION OF THE
LANDLORD'S REPRESENTATIVE.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.1 LEGENDS NOTES & ABBREVIATIONS.DWG
FOS
FRP
LL
MAX
MC
MDF
MECH
MEP
INFORMATION
INDIRECT WASTE
KITCHEN EQUIPMENT
CONSULTANT
LANDLORD
MAXIMUM
MECHANICAL CONTRACTOR
MEDIUM DENSITY FIBERBOARD
MECHANICAL
MECHANICAL, ELECTRICAL
AND PLUMBING
MANUFACTURER
MINIMUM
NATURAL
NOT IN CONTRACT
NIGHT LIGHT
NATIONAL SANITATION
FOUNDATION
NOT TO SCALE
OVER ALL
ON CENTER
OUTSIDE DIAMETER
OUTSIDE FACE
OWNER FURNISHED ITEM
OPENING
OPPOSITE
PLUMBING CONTACTOR
PERPENDICULAR
PLASTIC LAMINATE
PLEXIGLAS
PLYWOOD
PROJECT MANAGER
POINT OF CONNECTION
POINT OF SALE
POTBELLY SANDWICH WORKS
POTBELLY SANDWICH WORKS HUBBARD WAREHOUSE
POTBELLY SANDWICH WORKS CONSTRUCTION SERVICES
PAINT
QUARRY TILE
RADIUS
RECEPTACLE
REFERENCE
REFRIGERATOR
REQUIRED
REVISED/REVISION
ROUND
REVERSE OSMOSIS
SOLID CORE
SQUARE FEET
SHEET
SHEET METAL
SIMILAR
SOLID
SPECIFICATION(S)
SQUARE
STAIN
STAINLESS STEEL
STORAGE
STRUCTURAL
STEEL
SUSPENDED
SOFTENED WATER
TONGUE & GROOVE
TELEPHONE
TEMPORARY
TYPICAL
UNDERCOUNTER
UNLESS NOTED OTHERWISE
VENT
VALIDATION
VINYL COMPOSITION TILE
VENDOR
VERTICAL
VERIFY IN FIELD
WOOD
WATER HEATER
TRANSFORMER
WITH THE WASHERS AND WING NUTS (THESE CANNOT BE USED WITH THE TOP FRAME).
B. PRE-DRILL 5 PILOT HOLES IN THE TOP OF ONE SIDE OF THE A-FRAME STRUCTURE. (THE TOP
FRAME ONLY FASTENS TO ONE SIDE SO IT CAN STILL OPEN AND CLOSE)
C. PLACE THE TOP FRAME ON TOP OF THE FULLY OPENED A-FRAME AND ADJUST SO THAT IT
SITS LEVEL.
D. SCREW UP THROUGH THE A-FRAME INTO THE BOTTOM OF THE TOP FRAME WITH THE 5
PROVIDED SCREWS (SEE SKETCH).
SHEET TITLE
LEGENDS
NOTES &
ABBREVIATIONS
JYOU
FIXT
FLEX
FOC
FOG
FOH
FOIC
INFO
IW
KEC
DECOR INSTALL NOTES
SHEET NUMBER
A0.1
3/18/2010 12:52:23 PM
FIN
FIO
AIR CONDITIONING
ACCESSIBLE
ACOUSTICAL CEILING TILE
ADJUSTABLE
ABOVE FINISHED FLOOR
ALUMINUM
AMPERAGE
APPROXIMATE
ARCHITECTURAL
BOARD
BUILDING
BLOCKING
BOTTOM OF BEAM
BACK OF HOUSE
CABINET
CONDENSATE DRAIN
CIRCUIT
CEILING
CLEAR/CLEARANCE
CONSTRUCTION MANAGER
CEMENT
CONCRETE MASONRY UNIT
CENTERS
COMPANY
COORDINATE
CENTER
CENTERLINE
COLUMN
COMPARTMENT
CONCRETE
CONTINUOUS
CONSTRUCTION
COORDINATE
CERAMIC TILE
COLD WATER
DEGREES
DIAMETER
DIMENSION
DOWN
DETAIL
DISHWASHER
DRAWINGS
EACH
ELECTRICAL CONTRACTOR
ELECTRICAL
ELEVATION
EQUAL
EQUIPMENT
EXISTING
EXPOSED
EXTERIOR
FLOOR CLEANOUT
FURNITURE, FURNISHINGS
AND EQUIPMENT
FINISHED
FURNISHED & INSTALLED
BY OWNER
FIXTURE
FLEXIBLE
FACE OF CABINET
FACE OF GLAZING
FRONT OF HOUSE
FURNISHED BY OWNER &
INSTALLED BY CONTRACTOR
FACE OF STUD
FIBERGLASS REINFORCED
PANEL
FIRE PROTECTION
FLOOR
FRAME
FOOT/FEET
FIELD VERIFY
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GROUND
GYPSUM WALL BOARD
HOLLOW CORE
HEAD
HEADER
HARDWOOD
HARDWARE
HOLLOW METAL
HORIZONTAL
HOUR
HEIGHT
HEATING VENTILATING AIR
CONDITIONING
HOT WATER
INSIDE DIAMETER
INSIDE/INTERIOR FACE
INDEPENDENT GROUND
INSULATION
GENERAL NOTES
PROJECT NUMBER: 16-059
AC
ACC
ACT
ADJ
AFF
ALUM
AMP
APPROX
ARCH
BD
BLDG
BLKG
BOB
BOH
CAB
CD
CKT
CLG
CLR
CM
CMNT
CMU
CNTRS
CO
COORD
CTR
CL
COL
COMP
CONC
CONT
CONST
COORD
CT
CW
DEG
DIA
DIM
DN
DTL
DW
DWG(S)
EA
EC
ELEC
ELEV
EQ
EQUIP
EXIST
EXP
EXT
FCO
FFE
SYMBOLS LEGEND
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ABBREVIATIONS
OCCUPANCY CALCULATION
KITCHEN - SERVICE/PREP= 669 SQ. FT. / 200 SF PER OCC
= 3 OCCUPANTS
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
ASSEMBLY - RESTAURANTS = 1,193 SQ. FT. /15 SF PER OCC = 80
(49 INTERIOR DINING SEATS & 12 EXTERIOR SEATS)
TOTAL = 83 OCCUPANTS (80 - DINING ROOM, 3 KITCHEN)
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
KEY NOTES
1
ADA TABLE LOCATION
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
EXITING CALCULATION
WALK-IN
COOLER/
FREEZER
SERVICE
LINE
PREP
ROOM
GENERAL NOTES
A.
DASHED LINE INDICATES CLEAR PATH OF EGRESS
NOTE: Posting of occupant load. Every room or space that is
an assembly occupancy shall have the occupant load of the
room or space posted in a conspicuous place, near the main exit
or exit access doorway from the room or space. Posted signs
shall be of an approved legible permanent design and shall be
maintained by the owner or authorized agent.
8'-1"
18'-5"
ISSUE DATE
6'-3"
26'-8"
6'-3"
16'-11"
14'-11"
30'-10"
4'-11"
PROJECT NUMBER: 16-059
QUEUING
AREA
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
MAXIMUM TRAVEL DISTANCE ALLOWED (SPRINKLED) - 250'
MAXIMUM TRAVEL DISTANCE PROVIDED
DINING 42'-9"
KITCHEN 63'-6"
TOILET
ROOM
VESTIBULE
4'-11"
"
2
8'-
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
5'-0"
8'-0"
"
3"
"
8'-
9'-3"
3
6'-
17'-2
6'-7"
26'-9"
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A0.2 EGRESS PLAN.DWG
4'-2"
2'-0"
MUSICIAN
AREA
DINING
ROOM
WOMEN'S
TOILET
ROOM
MEN'S
TOILET
ROOM
EGRESS
PLAN
UTILITY
CLOSET
NORTH
JYOU
SHEET TITLE
01 EGRESS PLAN
SCALE: 1/4"=1'-0"
A0.2
3/18/2010 12:53:00 PM
SHEET NUMBER
KEY NOTES
63'-10"
61'-6"
61'-0"
1
FLOOR DRAIN. REFER TO PLUMBING DRAWINGS FOR MORE
INFORMATION.
2
FLOOR SINK. REFER TO PLUMBING DRAWINGS FOR MORE
INFORMATION.
3
NOT USED
4
STUB-UP PENETRATION TO BE LOCATED ON CENTERLINE OF WALL
OR AS REQUIRED PER CONDITIONS.
5
FLOOR PENETRATION FOR TOILET. REFER TO MANUFACTURER'S
CUTSHEET FOR STUB-UP LOCATION RELATIVE TO FINISHED WALL.
6
WASTE LINE PENETRATIONS. SEE PLUMBING SHEETS FOR
INDIVIDUAL LINE SPECIFICATIONS.
7
NOT USED
8
FLOOR CLEANOUT. REFER TO PLUMBING DRAWINGS FOR MORE
INFORMATION.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
52'-3"
44'-5 1/2"
44'-4"
28'-11"
28'-5"
3'-0"
1'-11"
4
P206
P208
1
P206
2
2
1
P208
8'-10 1/2"
10'-0"
10'-10 1/2"
13'-9"
16'-5"
16'-10 1/2"
2
7'-8"
P206
1'-6"
4'-6"
2'-6"
5'-0"
2
4
1'-8"
4
2'-0"
4
P206
P208
1
4
5
A.
G.C. RESPONSIBLE FOR CONCRETE SLAB AFTER INSTALLING UTILITIES
UNDER SLAB. COORDINATE WITH LANDLORD.
5
P208
1
GENERAL NOTES
PROJECT NUMBER: 16-059
15'-1 1/2"
14'-8"
14'-3"
13'-1 1/2"
10'-1"
8'-8"
8'-0 1/2"
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
21'-9 1/2"
ISSUE DATE
1
ISSUE
DD SET
95% SET
6
P208
4
P208
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.0 TRENCHING & PENETRATION PLAN.DWG
1
DATE
04-26-2016
05-23-2016
1'-5"
4'-6"
NORTH
PENETRATION
& TRENCHING
PLAN
JYOU
SHEET TITLE
SHEET NUMBER
TRENCHING & PENETRATION PLAN
SCALE: 1/4" = 1'-0"
A1.0
----
01
KEY NOTES
WALL TYPE LEGEND
4'-4" AFF
5C
5D
4'-0" AFF
COOLER / FREEZER WALL:
BY MANUFACTURER
EXISTING STRUCTURAL BUILDING COMPONENTS
(COLUMNS, BEAMS, TRUSSES) TO REMAIN. MAINTAIN
EXISTING RATING AS REQ'D BY LOCAL CODES.
3
ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS
4
NOT USED
PARTIAL HEIGHT WALL (QUEUING LINE WALL):
20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 34" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT.
WALK-IN
COOLER/
FREEZER
SERVICE
LINE
PREP
ROOM
71'-2 1/2" VIF
INTERIOR DIMENSION
1'-2"
6'-0"
29'-3"
5
NOT USED
6
NOT USED
7
WROUGHT IRON STANCHIONS WITH QUEUING LINE CHAIN.
REFER TO DETAIL 13/A5.0.
8
G.C. CONSTRUCTED DIEWALL WITH CASEWORK PANELS AT
SERVICE COUNTER. REFER TO SHEET A1.5.
9
FRAMED OPENING WITH 11-1/2" CURB FOR REACH-IN COOLER.
COORDINATE WITH EQUIPMENT. REFER TO DETAIL 04/A5.0.
10
CLOSURE ANGLE. SEE DETAIL 09/A5.0.
23'-6 1/2"
6'-2"
11
PROVIDE CONTINUOUS BLOCKING IN PARTITION FOR
WALL-HUNG LAVATORY, GRAB BARS, BABY CHANGING
STATION, ETC. REFER TO ENLARGED PLAN DETAIL13/A1.6
12
EXISTING ALUMINUM STOREFRONT
13
OVERHEAD CABINETS AT BACKLINE, REFER TO INTERIOR
ELEVATIONS FOR LOCATION. PROVIDE BLOCKING IN WALL.
14
STAINLESS STEEL CORNER GUARD
15
NOT USED
12
16
2
13
13
4
1
2
3
14
A5.0
02
A4.0
03
A4.3
01
A4.3
03
A4.0
1
2'-3"
14
2'-3"
1
A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
13
A1.6
D005
3A
2
3A
3
12
8
9
3'-9"
7
TYP
5'-3"
D001
9'-7"
3
03
A4.1
2A
02
A4.1
2A
8'-6" HOLD
A5.1
2A
2
2
D002
4
6"
2A
2
01
A4.2
2
14
1
D007
2
6'-0 1/2"
2
04
A4.1
2
7'-9"
COOLER DIM
3'-8 1/2"
01
A4.1
3
D009
10
5'-1"
01
A4.4
2A
02
A4.1
5'-8"
02
A4.3
C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL &
INSIDE OF DOOR JAMB U.N.O.
2
D008
D006
25'-10"
2
9"
16
01
A4.0
B. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR
CONSTRUCTION PURPOSES.
29'-1" VIF
INTERIOR DIMENSION
03
A4.1
5'-0"
TYP
7"
A1.1a
C
7"
8
7
14'-5 1/2"
COOLER DIM
01
3'-8 1/2"
4
2
02
A4.4
4'-6"
5'-7"
TOILET
ROOM
VESTIBULE
02
A3.0
12
7'-0"
D010
2
MUSICIAN
AREA
01
CONSTRUCTION PLAN
12
03
A3.0
12
77'-9 1/2" VIF
INTERIOR DIMENSION
DINING
ROOM
C
Wells
H
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
R
955
S
0334
D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT &
SHELVING.
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS &
SPECIFICATIONS.
G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE
OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. ALL DOORS
EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR
WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT
EXCEED:
A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS.
B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS.
2A
H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF
EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE
FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL
KNOWLEDGE OR SPECIAL EFFORT.
2
12
R
4 0 4 S.
F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS.
1
04
A4.3
PROVIDE BLOCKING IN WALL FOR WALL HUNG MENU
BOARD AND BOH SHELVING. SEE INTERIOR ELEVATIONS
FOR MORE INFORMATION.
GENERAL NOTES
7'-10"
7'-11"
10
2A
01
A3.0
16
3
D004
22'-7 1/2"
12'-5"
04
A4.0
2
8'-9"
13
6
1
3'-10"
4
2'-3"
ALIGN
1
1
3'-2 1/2"
16
2
A
ILLINOIS DESIGN FIRM # 184.006688
CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION.
QUEUING
AREA
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.1 CONSTRUCTION PLAN.DWG
8
2
12
J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED.
WOMEN'S
TOILET
ROOM
MEN'S
TOILET
ROOM
UTILITY
CLOSET
NORTH
SCALE: 1/4" = 1'-0"
I. ADDITIONAL ROOF PENETRATIONS REQUIRED BY PSW SHALL BE
INSTALLED BY LANDLORD'S ROOF CONTRACTOR AT PSW'S
EXPENSE. VIOLATIONS OF THE LANDLORD'S ROOF
REQUIREMENTS WILL RESULT IN A SURRENDER OF PSW'S OR
CONTRACTOR'S SECURITY DEPOSIT. PSW SHALL HAVE THE
OPTION TO SET ALL CURBS AND SLEEVES FOR ROOF
PENETRATIONS PRIOR TO ROOF WORK BEING COMPLETE.
SHEET TITLE
CONSTRUCTION
PLAN
JYOU
4 85"
2'-10" AFF
SHEET NUMBER
A1.1
3/18/2010 1:14:04 PM
4A
5B
EXISTING DEMISING WALL. PATCH AND REPAIR GYP. BD. AS
REQUIRED TO MAINTAIN EXISTING RATING. CONFIRM WALL
CONSTRUCTION AND NOTIFY PSW OF ANY DISCREPANCIES
OR ISSUES.
PROJECT NUMBER: 16-059
4 41"
6 41"
4
1'-11" AFF
FURRED WALL TO 6" ABOVE CLG:
20 GA 3 58" MTL STUDS 16" OC WITH 58" TYPE "X" GWB ON ONE SIDE TO 13'-0" AFF. DRYWALL SCREWS AT 12" OC. APPLY
CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION.
7
FURRED PLUMBING WALL TO 6" ABOVE CLG:
20 GA 3 5/8" MTL STUDS @ 4 & 6" MTL STUDS @ 4A 16" OC WITH 85" GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG.
DRYWALL SCREWS AT 10" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 &
A5.3 FOR MORE INFORMATION.
EXISTING WALL
5A
1
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
4 87"
3A
5D
6
PLUMBING WALL TO 6" ABOVE CLG:
20 GA 3 5/8" MTL STUDS @ 3 & 6" MTL STUDS @ 3A WITH 58" GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG.
DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE
ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE
INFORMATION.
7 1/4"
3
5C
4 4"1
EXISTING WALL
2A
5B
5 81"
4 78"
2
5A
FULL HEIGHT PARTITION WALL:
20 GA 3 85" MTL STUDS 16" OC @ 2, & EXISTING STUDS @ 2A WITH 58" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE
CLG. IF APPLICABLE. DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE
TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3
FOR MORE INFORMATION.
PARTIAL HEIGHT WALL :
20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 1/2" PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT BELOW.
REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT BOARD AT BASE
WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION.
10 1/2"
EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION
1
KEY NOTES
EXISTING CONSTRUCTION TO REMAIN, PATCH & REPAIR TO LIKE NEW CONDITION
4 41"
4A
4 85"
5C
5D
4 4"1
5B
6
PLUMBING WALL TO 6" ABOVE CLG:
20 GA 3 5/8" MTL STUDS @ 3 & 6" MTL STUDS @ 3A WITH 58" GREEN BOARD ON ONE OR BOTH SIDES TO 6" ABOVE CLG.
DRYWALL SCREWS AT 10" OC. 45 DEGREE MTL STUD REINFORCEMENT AT 48" OC ABOVE CLG LINE TO STRUCTURE
ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE
INFORMATION.
5A
1'-11" AFF
2'-10" AFF
5B
5C
4'-4" AFF
5D
4'-0" AFF
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
FURRED WALL TO 6" ABOVE CLG:
20 GA 3 58" MTL STUDS 16" OC WITH 58" TYPE "X" GWB ON ONE SIDE TO 13'-0" AFF. DRYWALL SCREWS AT 12" OC. APPLY
CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION.
A
R
4 0 4 S.
COOLER / FREEZER WALL:
BY MANUFACTURER
7
FURRED PLUMBING WALL TO 6" ABOVE CLG:
20 GA 3 5/8" MTL STUDS @ 4 & 6" MTL STUDS @ 4A 16" OC WITH 58" GREEN BOARD ON ONE SIDE TO 6" ABOVE CLG.
DRYWALL SCREWS AT 10" OC. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 &
A5.3 FOR MORE INFORMATION.
8
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PARTIAL HEIGHT WALL (QUEUING LINE WALL):
20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 34" LUAN PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT.
CROSSHATCH INDICATES WALLS TO BE INSULATED. PROVIDE R13 MINIMUM BATT INSULATION.
GENERAL NOTES
A. GC TO VERIFY ALL DIMENSIONS AND NOTIFY PSW
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
02
A5.4
C. ALL DIMENSIONS ARE TAKEN FROM FACE OF FINISH WALL &
INSIDE OF DOOR JAMB U.N.O.
5C
D. REFER TO SHEET A1.4 FOR FURNITURE, EQUIPMENT &
SHELVING.
3'-2"
10'-5"
2'-8"
ALIGN
B. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS FOR
CONSTRUCTION PURPOSES.
PROJECT NUMBER: 16-059
4
6 41"
EXISTING WALL
FULL HEIGHT PARTITION WALL:
20 GA 3 58" MTL STUDS 16" OC @ 2, & EXISTING STUDS @ 2A WITH 85" TYPE "X" GWB ON BOTH SIDES TO DECK OR 6" ABOVE
CLG. IF APPLICABLE. DRYWALL SCREWS AT 12" OC. 45 DEGREE MTL STUD REINFORMCEMENT AT 48" OC ABOVE CLG LINE
TO STRUCTURE ABOVE. APPLY CEMENT BOARD AT BASE WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3
FOR MORE INFORMATION.
PARTIAL HEIGHT WALL :
20 GA 3 58" MTL STUDS 16" OC AND 2"X2"' STEEL PIPES WITH 1/2" PLYWOOD ON BOTH SIDES TO SPECIFIED HEIGHT BELOW.
REFER TO WALL SECTIONS ON A5.4 FOR MORE INFORMATION ON CONSTRUCTION. APPLY CEMENT BOARD AT BASE
WHERE WATERPROOFING IS APPLIED. REFER TO A1.3 & A5.3 FOR MORE INFORMATION.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
3A
5A
5 81"
3
EXISTING WALL
4 87"
2A
7 1/4"
2
4 78"
1
10 1/2"
WALL TYPE LEGEND
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
E. REFER TO PLUMBING SHEETS FOR FIXTURE LOCATIONS &
SPECIFICATIONS.
29'-8"
5B
6'-10"
3'-6"
F. REFER TO SHEET A2.0 FOR DOOR SCHEDULE AND DETAILS.
3'-0"
G. ALL MEANS OF EGRESS DOOR OPENING HARDWARE SHALL BE
OPERATED BY A SINGLE HAND WITHOUT MEANS OF TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. ALL DOORS
EQUIPPED WITH PANIC HARDWARE MUST MAINTAIN A 32" CLEAR
WIDTH. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT
EXCEED:
A. 8.5 L.B.F. (37.7N) FOR EXTERIOR DOORS.
B. 5.0 L.B.F. (22.2N) FOR INTERIOR DOORS.
5C
01
A5.4
03
A5.4
04
A5.4
02
A5.4
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.1A ENLARGED CONSTRUCTION PLAN.DWG
3'-10"
8'-9"
01
A5.4
H. DOORS INDICATED AS PART OF THE REQUIRED MEANS OF
EGRESS SHALL HAVE HARDWARE WHICH IS READILY OPERABLE
FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY, SPECIAL
KNOWLEDGE OR SPECIAL EFFORT.
J. PROVIDE FIRE TREATED WOOD BLOCKING WHERE REQUIRED.
NORTH
ENLARGED
SERVICE LINE
PLAN
JYOU
SHEET TITLE
01
ENLARGED SERVICE LINE CONSTRUCTION PLAN
SCALE: 3/8" = 1'-0"
A1.1a
3/18/2010 1:14:04 PM
SHEET NUMBER
KEY NOTES
29'-9"
05
A5.2
5'-0"
3'-6"
5 1/2"
EQ
EQ
1'-6"
1'-6"
2'-6"
1'-6"
10'-11"
HOOD DIMENSION CENTERLINE
01 ENLARGED REFLECTED CEILING PLAN
SERVICE
LINE
OPEN TO
STRUCTURE
10'-1" A.F.F.
CL-06
WALK-IN
COOLER/
FREEZER
CL-08
3
SUBMARINE DUCT WITH ROTATING PROPELLER. REFER
TO DETAIL 13/A5.2 AND MECHANICAL DRAWINGS FOR
MORE INFO
4
NOT USED
5
KITCHEN EXHAUST HOOD. REFER TO MECH DRAWINGS
FOR MORE INFORMATION
NOT USED
7
NOT USED
8
MARKETING HANGING SIGN, REFER TO DETAIL 08/A5.2
9
NOT USED
10
NOT USED
11
CEILING HUNG MARKETING SIGN/MENU.
12
CUT DOWN CEILING HUNG TRACK TO MATCH GIVEN
DIMENSION.
13
3/8"=1'-0"
SCALE:
2x4 VINYL CEILING TILE - WHITE
10'-6" A.F.F.
CL-01
GYP. BD. BULKHEAD W/ WOOD TRIM
01
1
L500
1'-6"
L210
3'-1"
C
3'-6"
EQ
1'-6"
A1.2
5
L302
L302
L602
2' X 2' LAY-IN METAL CLG. PANEL. IN
METAL CEILING GRID W/ 12" X 12"
PATTERN (FULL PANELS TO BE
CENTERED OVER SERVICE AREA)
L302
04
A5.2
5
L502
L104
L102
2'-6"
1'-2"
L208
L617
L617
7'-6"
S203
8 11
L107
L107
L107
2
5'-10"
3'-6"
L500
EQ
EQ
03
A5.2
L200
L500
7'-8"
L208
EQ
PT-04
L305
L617
L208
L615
L109
L208
L618
L109
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
C
EQ
5'-0"
EQ
EQ
5'-0"
EQ
EQ
5'-0"
S100
L100
L100
L100
L500
L100
MUSICIAN
AREA
DINING
ROOM
OPEN TO
STRUCTURE
OPEN TO
STRUCTURE
PT-19
REFLECTED CEILING PLAN
PT-19
L100
L100
L208
L615
L618
L208
L615
L617
EQ
L100
R
S
0334
C. COORDINATE LOCATIONS OF WALL MOUNTED J-BOXES
WITH ELEVATIONS.
D. ALL MECHANICAL DIFFUSERS AND SUPPLY GRILLES TO
BE PAINTED TO MATCH SURROUNDING MATERIAL.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
E. SPRINKLER HEADS (IF REQUIRED) WITHIN 10'-0" OF
OVEN SHOULD BE HIGH HEAT RATED.
H. PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR EACH
FIXTURE.
S
L502
2'-0"
E
955
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
G. ALL DIMENSIONS ARE FROM WALL FINISH TO WALL
FINISH.
J. CONFIRM RECEIPT AND STORE FIXTURES UPON
ARRIVAL AT SITE.
L601
WINDOW
02
H
3'-0"
L102
L601
C
Wells
F. ALL EXPOSED DUCTWORK, BEAMS, JOISTS, DECKING,
PIPES, CONDUIT, ETC. AT CEILING SPACE THROUGHOUT
DINING & QUEUING AREAS SHALL BE PAINTED AS NOTED.
EQ
8'-0"
L109
4'-0"
L615
8'-0"
1'-6"
2'-0"
TOILET
ROOM
VESTIBULE
C
5'-10"
EQ
EQ
EQ
B. REFER TO SHEET A2.4 FOR SIGNAGE SCHEDULE.
8'-6" A.F.F.
L502
R
4 0 4 S.
A. REFER TO SHEET A2.6 FOR LIGHT FIXTURE SCHEDULE
3'-0"
C
5'-10"
S
L202
2
L210
1'-6"
L617
L502
EQ
EQ
L615
L107
"
3'-0
EQ
L202
EQ
S220
L207
S
10
A5.2
EQ
L617
EQ
EQ
7'-7 1/2"
L208
L615
S100
GENERAL NOTES
L203
7'-0"
L614
EQ
EQ
EQ
L615
S
EQ
C
EQ
EQ
1'-6"
C
L104
L602
L302
2'-6"
8'-10 1/2"
PAINTED GYP. BD. CEILING
L602
EQ
L613
L500
S
1'-8 1/2"
L208
1'-8 1/2"
L617
3'-0"
5'-0"
C
L615
A
CLD TO BE USED ON TRACK FIXTURES ONLY IF
REQUIRED BY CODE. ELECTRICAL ENGINEER TO
VERIFY.
MANUF
L613
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
LEGEND
PREP
ROOM
8'-0" A.F.F.
PT-19
PREFABRICATED COOLER CEILING
PROJECT NUMBER: 16-059
QUEUING
AREA
2
ILLINOIS DESIGN FIRM # 184.006688
15
A5.2
5'-0"
1'-6" X 1'-6" GYP. BOARD SOFFIT AT BAG IN THE BOX.
6
1'-9"
4'-6"
1
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
5'-0"
2'-0"
8'-0"
HOOD DIMENSION CENTERLINE
ALIGN
3'-6"
10'-6"
4"
2'-6"
8'-2"
HOOD DIMENSION CENTERLINE
HOOD DIMENSION CENTERLINE
K. PROVIDE AND INSTALL CONDUIT, J-BOXES, AND WIRING
FOR ALL FIXTURES.
L500
WOMEN'S
TOILET
ROOM
8'-6" A.F.F.
PT-04
MEN'S
TOILET
ROOM
8'-6" A.F.F.
L. COORDINATE LOCATIONS OF EMERGENCY LIGHTING AT
BACK SERVICE LINE WITH INTERIOR ELEVATIONS.
UTILITY
CLOSET
8'-6" A.F.F.
PT-04
M. REFER TO DETAIL 9/A5.2 FOR PENDANT LIGHT JBOX
MOUNTING DTL.
NORTH
PT-04
SCALE: 1/4" = 1'-0"
N. REFER TO DETAIL 14/A5.2 FOR CEILING FAN MOUNTING
DTL
O. REFER TO DETAIL 7/A5.2 & 12/A5.2 FOR TRACK LIGHT
MOUNTING DETAILS.
SHEET TITLE
REFLECTED
CEILING
PLAN
SHEET NUMBER
A1.2
ROOM FINISH SCHEDULE
WALLS
CEILING
WOOD
PAINT,
WALLCOVERING,
WOOD
CEILING HEIGHT
OPEN, PAINT
PAINT
OPEN
QUARRY TILE
CERAMIC TILE, PAINT
METAL PANEL
10'-1"
QUARRY TILE
QUARRY TILE
FRP, PAINT
ACT
10'-6"
CERAMIC TILE
WOOD
PAINT,
WALLCOVERING
GYP. BOARD, PAINT
8'-6"
GYP. BOARD, PAINT
8'-6"
CONCRETE
WOOD
SERVICE LINE
QUARRY TILE
PREP AREA
TOILET ROOM
VESTIBULE
TAG
LEGEND
DESCRIPTION
SIZE
FT01
QUARRY
TILE
6"X6"
FT03
CERAMIC TILE WHITE
1"X1"
CERAMIC TILE BLACK
1"X1"
GROUT
REMARKS
1
LEAVE OUT FLOOR FINISH AS NOTED
LATICRETE
#45 RAVEN
REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR
INSTALLATION INSTRUCTIONS
2
FREEZER FLOOR FINISH INCLUDED WITH
COOLER/FREEZER ASSEMBLY.
LATICRETE
#45 RAVEN
REFER TO ENLARGED PLAN DETAIL FOR PATTERN. REFER TO
ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION
INSTRUCTIONS
3
NOT USED
LATICRETE
#45 RAVEN
REFER TO ENLARGED PLAN DETAIL FOR PATTERN. REFER TO
ARCHITECTURAL SPECIFICATIONS SHEETS FOR INSTALLATION
INSTRUCTIONS
OPEN
OPEN, PAINT
QUEUING
COMMENTS
WOMEN'S TOILET ROOM
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE, PAINT
MEN'S TOILET ROOM
CERAMIC TILE
CERAMIC TILE
CERAMIC TILE, PAINT
GYP. BOARD, PAINT
8'-6"
WALK-IN COOLER
QUARRY TILE
QUARRY TILE
STAINLESS STEEL
STAINLESS STEEL
8'-0"
WALK-IN FREEZER
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
8'-0"
UTILITY CLOSET
QUARRY TILE
QUARRY TILE
FRP, PAINT
ACT
8'-6"
QUEUING
AREA
FT04
3'X3' SCORING
WITH 1/8"W X
1/8"D MAX.
CONCRETE
TOPPING
FT05
REFER TO ARCHITECTURAL SPECIFICATIONS SHEETS FOR
INSTALLATION AND FINISHING INSTRUCTIONS
N/A
4
NOT USED
5
FLOOR SINK/DRAIN LOCATION. REFER TO PLUMBING
DRAWINGS FOR DETAILS.
6
SLOPE 1/8" PER FOOT TO DRAINS.
7
WALK OFF MAT
FT16
WALK-IN
COOLER/
FREEZER
SERVICE
LINE
FT05
FT01
WB04
WB01
12 X 9
APPLY BEAD OF SILICONE AROUND PERIMETER OF DINING
ROOM WHERE WOOD BASE MEETS CONCRETE FLOOR.
USE CLEAR SILICONE.
REFER TO CONSTRUCTION BINDER FOR INSTALLATION
INSTRUCTIONS
N/A
PREP
ROOM
FT01
WB01
FT01
10
A5.3
P206
5
14
A5.3
P206
P208
03
A5.3
5
P206
5
5
P208
5
GENERAL NOTES
P206
P208
6"
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
WB01
5
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
5
6
A. REFER TO FINISH SCHEDULE ON SHEET A2.1 & A2.2 FOR
MORE INFORMATION.
02
A5.3
B. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED AS
PER PSW SPECIFICATIONS, NO SUBSTITUTIONS.
6
15
A5.3
P208
C.
5
D. ALL AREAS INDICATED TO RECEIVE WATERPROOFING WHICH
ARE NOT SLAB ON GRADE TO HAVE FULL WATERPROOFING
INSTALLED AND RUN 6" UP WALL AND MILLWORK.
6
TOILET
ROOM
VESTIBULE
P208
5
5'-0"
6
FT03
1
11
A5.3
LINE DESIGNATES LIMITS OF WATERPROOFING.
FT04
E. ALL AREAS INDICATED TO RECEIVE WATERPROOFING WHICH
ARE SLAB ON GRADE TO HAVE WATERPROOFING INSTALLED 6"
UP WALL & MILLWORK AND 6" OUT ON FLOOR.
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
F. ALL CUT TILES TO BE PUMICED SMOOTH.
WB02
4'-8"
1
2
6
H. PROVIDE LEVELING AGENT AS DEEMED NECESSARY TO
ALLOW ACCEPTABLE FINISH FOR FLOOR TILE.
08
A5.3
0"
3'-
5
3'-
0"
08
A5.3
G. INSTALL QUARRY TILE COVE BASE AT SERVICE LINE DIE
WALL AFTER CABINETRY HAS BEEN SET.
P208
05
A5.3
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.3 FLOOR FINISH PLAN.DWG
CONCRETE
BASE
PROJECT NUMBER: 16-059
DINING
FLOOR
KEY NOTES
*REFER TO SHEET A2.1 FOR FINISH SCHEDULE*
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ROOM NAME
FLOOR FINISH LEGEND
7
6"
09
A5.3
CONCRETE SCORING
PATTERN START POINT
DINING
ROOM
FT05
FT05
WB04
WB04
WOMEN'S
TOILET
ROOM
FT03
WB02
01
FT04
MEN'S
TOILET
ROOM
FT03
FT04
UTILITY
CLOSET
FT01
NORTH
WB01
FLOOR
FINISH
PLAN
SHEET NUMBER
WB02
FLOOR FINISH PLAN
SCALE:
1/4" = 1'-0"
A1.3
3/18/2010 1:17:52 PM
MUSICIAN
AREA
JYOU
SHEET TITLE
KEY NOTES
1
INSTALL 3-COMP SINK MINIMUM OF 3" OFF OF SIDE
WALLS, IF SPACE ALLOWS.
2
INTERIOR WINDOW SHADES AT WINDOWS AS
INDICATED
3
BAG-N-BOX. REFER TO DETAIL 11/A5.0
4
PROVIDE BLOCKING IN WALL
5
INSTALL MANAGER'S DESK MINIMUM OF 2" OFF OF
SIDE WALL.
6
7
GC TO PROVIDE AND INSTALL 4'-0" LENGTH OF STRAIGHT
LINK MACHINE CHAIN, #4 SIZE AND COMBINATION PAD LOCK
FOR CO2 TANK.
APPLY SILICONE SEAL AROUND PERIMETER OF SAFE. USE
CLEAR SILICONE.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
WALK-IN
COOLER/
FREEZER
SERVICE
LINE
PREP
ROOM
M121
M114
E403
M113
E401
E226
E410
E304
E248
E201
E409
M109
P204
A. REFER TO FFE SCHEDULES ON SHEET A2.2-A2.5 FOR TAG
DESIGNATIONS.
M115
B. ALL EQUIPMENT AND INSTALLATION TO MEET SDF STANDARDS
OR EQUIVALENT.
M107
E402
E215
P601
M107
P603
P406
P211
P805
M143
P600
M141
P201
E247
C. G.C. TO SET EQUIPMENT AND FURNITURE AS PER THIS SHEET.
MAINTAIN CLEARANCE WIDTHS AS PER ACCESSIBILITY GUIDELINES
AND DIMENSIONS AS PER SHEET A0.1.
P605
P401
5
1
7
D.
HATCHING INDICATES MILLWORK ITEMS, REFER
TO SHEET A1.2 FOR FURTHER INFORMATION.
F302
2
E. WHERE GC IS REQUIRED TO INSTALL ANY FIXED SEATING,
TABLES, COUNTERS, ETC., A REMOVABLE SCREW IS TO BE TAPPED
INTO FLOORING, NOT NAILED.
F121
F302
M146
E250
E252
E403
M103
M106
E251
3
S204
E105
6
M111
M136
S201
E207
P702
S221
13
F121
A1.6
F302
F301
2
S223
E406
F117
E304
E226
F502
S101
M113
E221
E302
4
E208
S203
E103
M123
F115
F300
F201
F301
2
F203
F110
F206
F300
F301
F109
F501
F301
F206
F109
F501
F301
F206
S219
F108
F301
P210
M135
S207
S208
E213
E222
E219
TOILET
ROOM
VESTIBULE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
M104
S220
4
S213
S225
S224
F200
F200
F300
F102
F101
P807
S225
F500
S222A
F201
F107
4 S216A
F200
F300
F301
ISSUE DATE
P205
P102
S207
M112
P401
P210
P102
P715
M155
S209
M111
E223
F102
F200
F300
F102
F200
F300
F101
E221
E222
P800
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.4 FURNITURE FIXTURE AND EQUIPMENT
PLAN.DWG
P405
F300
E221
F200
F300
F112
F300
F301
F407
13'-4"
F301
F113
F201
S101
S222A
F407
F121
F121
F121
F121
F302
F302
F302
F302
MUSICIAN
AREA
DINING
ROOM
F301
F100
F201
F301
F112
F304
F200
F101
F100
F200
F200
SHEET TITLE
WOMEN'S
TOILET
ROOM
MEN'S
TOILET
ROOM
FF & E
PLAN
UTILITY
CLOSET
JYOU
11'-0"
F302
P410
4
PROJECT NUMBER: 16-059
QUEUING
AREA
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
GENERAL NOTES
NORTH
01
FURNITURE, FIXTURE AND EQUIPMENT PLAN
SCALE: 1/4" = 1'-0"
A1.4
6/18/2009 5:13:48 PM
SHEET NUMBER
KEY NOTES
QUEUING
AREA
WALK-IN
COOLER/
FREEZER
SERVICE
LINE
PREP
ROOM
C122
2
5
GC TO SUPPLY DURAROCK AT SERVICE LINE SIDE OF
END WALL AS INDICATED.
A1.5
7
4 HIGH CHIP CUBBIE TO SIT ON WALL
C300
8
COORDINATE THE LOCATION OF PANELS AND SPRAY
PAINT PLYWOOD SUBSTRATE WITH BLACK PAINT TO
HIDE EXPOSED REVEAL BETWEEN MILLWORK PANELS.
COORDINATE AS NEEDED AND PAINT PRIOR TO PANEL
INSTALL.
9
1" METAL SUPPORT POST. PROVIDED BY RETAIL
INSTALLED BY GC.
10
CHALK BOARD PANELS BETWEEN METAL SUPPORT
POSTS. PROVIDED BY RETAIL, INSTALLED BY GC.
11
2" PIPE LEG SUPPORT. PROVIDED BY RETAIL INSTALLED
BY GC.
12
SOLID SURFACE POS SHROUDS. INSTALLATION OF
SHROUDS SHOULD BE COORDINATED WITH POS
INSTALLATION.
13
ADD GROMMET LOCATIONS IN FIELD AT POS COUNTER.
03
C304
A1.5
8
C121
TYP.
C303
C301
C205
1'-6"
C204
6
6
7
C203
C202
6
6
C201
W312
V208
W317
W319
W304
W320
COOLER
TRIM
W305
BEADBOARD
W315
V208
2'-6"
W305
BEADBOARD
W304
W305
BEADBOARD
1
W304
W305
BEADBOARD
W304
C134
TOILET
ROOM
VESTIBULE
W304
V209
W322
1'-6"
C123
C200
W316
3
W305
BEADBOARD
W312
W304
W322
W312
V208
C125
W305
BEADBOARD
GENERAL NOTES
A. REFER TO CASEWORK SCHEDULE SHEET A2.7 & A2.8
FOR INFORMATION.
MUSICIAN
AREA
DINING
ROOM
WOMEN'S
TOILET
ROOM
MEN'S
TOILET
ROOM
UTILITY
CLOSET
NORTH
C. GC TO TOUCH UP CASEWORK PIECES AS NEEDED UPON
COMPLETION USING VENDOR PROVIDED TOUCH UP KIT.
D. GC TO CAULK ALL EXPOSED SEAMS, JOINTS, ETC. WITH
CLEAR SILICONE SEALANT. DO NOT CAULK MOVEABLE
CASEWORK PIECES TO WALL.
CASEWORK PLAN
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
A104 11
11 A104
A103 10
10 A103
A100
9
9
A100
8"
1'-10"
8"
2"
1'-10"
Count
4
2
2
1
1
A107 12
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.5 CASEWORK PLAN.DWG
SCALE: 1/4" = 1'-0"
CASEWORK ACCESSORIES
ITEM
A100
A103
A104
A105
A107
B. ALL MDF TRIM TO COME PRIMED FROM VENDOR. GC TO
APPLY FINAL FINISH IN FIELD. REFER TO CASEWORK
SCHEDULE FOR FINISH DESIGNATIONS.
SHEET TITLE
CASEWORK
PLAN
1'-1"
01
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
JYOU
1
NOT USED
AFFIX MILLWORK PANELS & TOP CAP TO FACE/TOP OF
DIE WALL AS PER MILLWORK SHOP DRAWINGS.
02
6
4
6
C306
C206
REFER TO ELEVATION SHEETS FOR LOCATION AND
FINISH OF PICTURE FRAME.
1'-2"
SHEET NUMBER
02 ENLARGED DETAIL
SCALE: 1/2" = 1'-0"
03 ENLARGED DETAIL
SCALE: 1/2" = 1'-0"
A1.5
6/18/2009 5:14:17 PM
6
3
W305
5'-0"
W305
BEADBOARD
REFER TO ELEVATION SHEETS FOR LOCATION OF
CHAIR RAIL AT TILE.
V201
1'-10"
W309
W304
2
PROJECT NUMBER: 16-059
6"
1 X 2 WOOD TRIM AT FINISH TRANSITION. REFER TO
ELEVATIONS FOR MORE INFORMATION.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
C130
1
1'-8 1/2"
SURFACE MOUNTED
LIGHT FIXTURE
1'-6"
WALL SCONCE
SURFACE MOUNTED
LIGHT FIXTURE
CLEANING
CHECKLIST
PAPER TOWEL
DISPENSER
MOTION SENSOR
LIGHT SWITCH
SOAP DISPENSER
MIRROR
A
1'-6"
FLOOR MOUNTED
WATER CLOSET
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
5'-0"
WALL HUNG
LAVATORY
COAT HOOK
A
01
C
Wells
ILLINOIS DESIGN FIRM # 184.006688
4'-4"
B.O. SIGN
EQ.
3'-4"
B.O. MIRROR GLASS
2'-10"
T.O. SINK
3'-4"
REFER TO
CUTSHEET
3'-0"
1'-5"
1'-7"
3'-3"
3'-0"
5'-0"
EQ.
TOILET PAPER
DISPENSER
R
4 0 4 S.
4'-0"
T.O. LIGHT SWITCH
36" HORIZONTAL
GRAB BAR
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
D
C
TOILET ROOM ELEVATIONS
SCALE: 1/2" = 1'-0"
KEYNOTES
1
TOILET ROOM SIGNAGE - MEN & WOMEN WITH SYMBOL & BRAILLE. REFER TO DETAIL 07/A1.6 FOR MOUNTING LOCATION.
2
TOILET ROOM SIGNAGE - MEN & WOMEN VINYL LETTERS APPLIED TO
DOOR AT A MINIMUM OF 49" A.F.F. MEASURED TO THE BASELINE OF
THE LOWEST TACTILE CHARACTER AND A MAX OF 60" A.F.F. TO THE
BASELINE FO THE HIGHEST TACTILE CHARACTER.
PT05
WT04
3'-8"
14 COURSES
WT-0X
7'-6"
6"
TYP
7'-5"
2'-0" TYP
1'-0"
TYP
3'-0"
TYP
PROJECT NUMBER: 16-059
18" H VERTICAL
GRAB BAR
SURFACE MOUNTED
LIGHT FIXTURE
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
TOILET ROOM
CABINET
9'-2"
NOTE: PROVIDE CEMENT BOARD FROM FINISHED FLOOR TO 4'-0" AFF.
PROVIDE GREEN BOARD FROM 4'-0" TO FINISHED CEILING
GENERAL NOTES
P611B
P210
B
P406
01
A1.6
B. REFER TO SHEET A2.1 & A2.2 FOR FINISH SCHEDULE.
D
C. REFER TO SHEET A2.3 AND A2.4 FOR FFE SCHEDULES.
1'-6"
M209
C
S208
D. REFER TO ELEVATIONS THIS SHEET FOR ACCESSORY MOUNTING
HEIGHTS.
1
5'-3"
4'-1"
5'-2"
PROVIDE INSULATION
AT HOT WATER AND
DRAIN PIPES UNDER
LAVATORY
SHEET TITLE
ENLARGED TOILET
ROOM PLANS
& DETAILS
PROVIDE
WATERPROOFING UP
WALL 6"
11
SINK SECTION
SCALE: 1" = 1'-0"
JYOU
2'-10"
T.O. SINK
2'-5 1/4"
B.O. SINK
HOLD WATER/DRAIN
LINES AS HIGH AS
POSSIBLE
07
7"
7"
PROVIDE CLEAR
SEALANT AT
LAVATORY TO WALL
CONNECTION
3'-4"
B.O. MIRROR GLASS
-
07
OPP
DATE
04-26-2016
05-23-2016
A. REFER TO DETAIL 06/A1.6 FOR TYPICAL FINISH CALLOUTS IN TOILET
ROOMS.
A
1'-6"
TYP
ISSUE
DD SET
95% SET
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A1.6 ENLARGED TOILET ROOM PLANS &
DETAILS.DWG
SCALE: 1/2" = 1'-0"
3'-5"
1'-8 1/2"
07
ISSUE DATE
SHEET NUMBER
12
NOT USED
SCALE:
13
ENLARGED TOILET ROOM PLAN
SCALE: 1/2"=1'-0"
A1.6
2/4/2010 1:55:52 PM
SCALE: 1/2" = 1'-0"
TYPICAL DOOR ELEV.
3'-0" TYP M204
3'-3" TYP M203
TOILET WALL FINISH ELEV.
3'-6"
TYP
06
1'-0"
TYP
4"
WB02
HARDWARE GROUPS
W300
07
-
SET #8 AT PREP TO DINING DOOR TYPE G
AT RESTROOM DOOR TYPE G
(1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER HINGE CO., MODEL #BB1279 4
-1/2"X4-1/2" 10 A - LENGTH TO FIT DOOR HEIGHT PER MANUFACTURER
(1) SIMPLEX 5021 XS WL 744 41 KEYPAD LOCK
(1) WALL STOP, US10B, HAGER HINGE COMPANY, MODEL #236W
(1) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B
(1) CLOSER, HAGER 5100 X RW/PA DBZ
(1) ROCKWOOD 461 KICKDOWN US10B
(1) DOOR VIEWER, IVES MODEL #U698 B3
SILENCERS
(1) PR. HAGER BUTT HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER
HINGE CO., MODEL #BB1279 4 -1/2"X4-1/2" 10 A - LENGTH TO FIT DOOR
HEIGHT PER MANUFACTU
(1) WALL STOP, US10B, HAGER HINGE COMPANY, MODEL #236W
(1) 6"x34" KICK PLATES, HAGER, MODEL #190S-10B
(1) CLOSER, HAGER 5100 X RW/PA DBZ
(1) ROCKWOOD 461 KICKDOWN US10B
(1)
AVALON 613
SILENCERS
SET #9 AT SERVICE/PREP DOOR TYPE C
CONTACT ELIASON FOR MORE INFORMATION
ITEM NO: SCP-12-RHPTBELLY
ROD WAGNER: 269-615-1105 | [email protected]
SET #1A AT EXTERIOR ENTRY DOORS TYPE B
11
-
(1)
(1)
(1)
(1)
(1)
SET #7 AT CAFE DOOR TYPE E
DOOR TRIM DETAIL
B.
PROVIDE DOOR SILENCERS (3 PER DOOR) AT ALL DOORS. ALL EXTERIOR DOOR BUTTS TO HAVE
NON-RISING PINS. ALL HARDWARE TO HAVE OIL RUBBED ANTIQUE BRASS FINISH. NO POLISHED
BRASS.
C.
PINE OR POPLAR ARE ACCEPTABLE WOOD SPECIES FOR TRIM WHERE MDF IS NOT USED. SELECT
AVAILABLE SPECIES & USE THROUGHOUT.
D.
HOLLOW METAL DOORS AND FRAMES TO BE PAINTED, WOOD DOORS TO BE STAINED IN FIELD. SEE
AS1.2 FOR MORE INFO.
E.
GC TO VERIFY IF EXISTING HARDWARE ( PROVIDED BY LANDLORD) MEETS CODE ON ALL
EMERGENCY EXIT DOORS. IF NOT, GC TO PROVIDE AND INSTALL HARDWARE. VERIFY HARDWARE
TYPE WITH PSW CONSTRUCTION MANAGER.
F.
G.C. TO CONTACT POTBELLY VENDOR FOR HARDWARE.
BRIDGET JELONEK
LAFORCE, INC.
PH: 630.325.1950 x1603
EM: [email protected]
DOOR, FRAME AND HARDWARE SCHEDULE
NUMBER
FRP AS
SCHEDULED
1X6 WOOD
CASING
W308
1/4" SHIM SPACE
HOLLOW METAL
FRAME.
1X3 WOOD JAMB
W318
DOOR AS
SCHEDULED
3/4"
SERVICE
LOCATION
NOMINAL
SIZE
FRAME
MAT FIN
HARDWARE
HEAD JAMB THRSHLD
DOOR
TYPE MAT FIN PRVD INSTL DETAIL DETAIL DETAIL TYPE PRVD INSTL
REMARKS
EXISTING HARDWARE WITH
NEW CORES - CORES PROVIDED
AND INSTALLED BY VD - REFER
TO GENERAL NOTE E
D001
ENTRY (EXISTING) 3'-0" X 8'-0" X 1 3/4"
AL/G
-
B
ALUM
-
EX
EX
EX
EX
06/A5.3
1A
LL
LL
D002
UTILITY CLOSET
(2)3'-0" X 7'-0" X 1 3/4"
HM
PT-33
G
SC
ST-2
G.C.
G.C.
06/A2.0
06/A2.0
08/A5.3
8
G.C.
G.C.
D003
DINING / SERVICE
3'-0" X 2'-6" X 1 3/4"
WD
ST-3
E
SC
PLAM
G.C.
G.C.
-
12&13/A2.0
03/A5.3
7
G.C.
G.C.
DUAL ACTION DOOR
SWING
D004
SERVICE / PREP
3'-0" X 7'-0" X 1 3/4"
WD
ST-3
C
SC
PLAM
G.C.
G.C.
07/A2.0
11/A2.0
--
9
G.C.
G.C.
DUAL ACTION DOOR
SWING
D005
WALK-IN
REFRGIERATOR
BY V.D.
-
-
-
V.D.
V.D.
-
-
-
-
V.D.
V.D.
D006
WALK-IN FREEZER BY V.D.
-
-
-
V.D.
V.D.
-
-
-
-
V.D.
V.D.
D007
PREP/DINING
(HALL)
3'-0" X 7'-0" X 1 3/4"
HM
PT-33
G
SC
ST-2
G.C.
G.C.
06/A2.0
06/A2.0
08/A5.3
8
G.C.
G.C.
D008
WOMEN'S TOILET
ROOM
3'-0" X 7'-0" X 1 3/4"
HM
PT-33
G
SC
ST-2
G.C.
G.C.
06/A2.0
06/A2.0
5
G.C.
G.C.
PROVIDE HC 'WOMENS'
SIGNAGE
D009
MEN'S TOILET
ROOM
3'-0" X 7'-0" X 1 3/4"
HM
PT-33
G
SC
ST-2
G.C.
G.C.
06/A2.0
06/A2.0
5
G.C.
G.C.
PROVIDE HC 'MENS'
SIGNAGE
D010
REAR EXIT
(EXISTING)
3'-0" X 7'-0" X 1 3/4"
HM
PT-33
B
HM
PT-33
EX
EX
EX
EX
09/A5.3
6
LL
LL
ADDRESS/SIGNAGE
AS REQ'D BY LL
D011
SIDE ENTRY
(EXISTING)
3'-0" X 8'-0" X 1 3/4"
AL/G
-
B
ALUM
-
EX
EX
EX
EX
09/A5.3
1A
LL
LL
3/4"
PREP
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
ALL DOOR ACTIVATING HARDWARE SHALL BE INSTALLED BETWEEN 3'-2" A.F.F & 3'-8" A.F.F.
SCALE: 1/2" = 1'-0"
R
4 0 4 S.
A.
CONTACT ELIASON FOR MORE INFORMATION
ITEM NO: SCPCF-RHPTBELLY
ROD WAGNER: 269-615-1105 | [email protected]
01
A
GENERAL NOTES
HAGER (OR EQUAL) ROTON HINGES, TO MATCH STOREFRONT
SYSTEM, UL LISTED, HAGER HINGE CO., MODEL #780-224HD - LENGTH
TO FIT DOOR, HEIGHT PER MANUFACTURER
CLOSER, LCN, MODEL #4041 EDA W/ PA DKBZ
ALUMINUM THRESHOLD BY NATIONAL GUARD-(SUPPLIED BY G.C.)
PERIMETER WEATHER STRIPPING = NATIONAL GUARD NGP # 160V
DKB
SWEEPS = NATIONAL GUARD 1025 VDKB WITH SILENCERS
4" X 16" INT. PUSH PLATE, HAGER, #30S-US10B-SP313
PANIC BAR, VON DUPRIN, #22EO-SP313 EXIT ONLY- IF REQUIRED BY
CODE
EXTERIOR PULL, VON DUPRIN, #230DT- SP313 (NO CYLINDER HOLE)
(1)
(1)
(3)
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
EXISTING HARDWARE WITH
NEW CORES - CORES PROVIDED
AND INSTALLED BY VD - REFER
TO GENERAL NOTE E
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PROJECT NUMBER: 16-059
SET #5
(1) PR. HAGER ROTON HINGES, ANODIZED DARK BRONZE, UL LISTED, HAGER
HINGE CO., MODEL #780-224HD - LENGTH TO FIT DOOR, HEIGHT PER
MANUFACTURER
(2) 6"X34" KICK PLATES, HAGER, MODEL #190S-US10B
(1) CLOSER, LCN, MODEL #4041 EDA DKB
(1) PUSH BAR - PANIC HARDWARE, VON DUPRIN, #22EO-SP313
(1) EXTERIOR DOOR PULL, VON DUPRIN, #230DT-SP313 (NO CYLINDER HOLE)
(1) 4"X16" INTERIOR PUSH PLATE, HAGER, #30S-US10B (MOUNT BELOW PUSH
BAR)
(1) THRESHOLD BY NATIONAL GUARD-DARK BRONZE ANODIZED
(1) SWEEP W/ SILENCERS, NATIONAL GUARD 1025 VDKB
(1) HOLD OPEN, IVES, #FS544 SP313
WOOD CASING
DOOR STOP
AS NOTED
AT INTERIOR ENTRY
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
SET #2
ISSUE DATE
06
HEAD/JAMB DETAIL
SCALE:
3" = 1'-0"
07
HEAD DETAIL
SCALE:
3" = 1'-0"
08
NOT USED
ISSUE
DD SET
95% SET
SCALE:
DATE
04-26-2016
05-23-2016
DOOR TYPES
1
2"
SERVICE
SERVICE
1
2"
PLYWOOD
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.0 DOOR SCHEDULES & DETAILS.DWG
1X6 WOOD CASING
PLYWOOD
3/4"
7'-0"
W300
NOT USED
ELIASON - SCP12 - RHPTBELLY
(SINGLE DOOR) 3/4" SOLID CORE
LAMINATED
1/4" SHIM SPACE
3-5/8" METAL STUD
WITH WOOD BLOKING
5 1/2"
1/4" SHIM SPACE
5 1/2"
1/4" SHIM SPACE
3-5/8" METAL STUD
WITH WOOD BLOKING
EXISTING
A
C
3/4"
B
1
2"
PLYWOOD STRIP
3
4"
PANEL CLEAT
1
2"
PLYWOOD STRIP
HOLLOW METAL
FRAME
PAINT PT-33
1X3 WOOD JAMB
CASEWORK PANEL
3
4"
DINING
DINING
1X6 WOOD JAMB
CAFE DOOR
11
SCALE:
3" = 1'-0"
12
JAMB DETAIL
CAFE DOOR
SCALE:
3" = 1'-0"
13
JAMB DETAIL
DOOR VIEWER
CASEWORK PANEL
1X6 WOOD JAMB
JAMB DETAIL
PANEL CLEAT
HOLLOW METAL
DOOR
PAINT PT-33
3" = 1'-0"
SOLID CORE
DOOR
STAIN ST-02
NOT USED
SHEET TITLE
DOOR
SCHEDULES &
DETAILS
SHEET NUMBER
EXISTING
D
SCALE:
ELIASON - SCPCF - RHPTBELLY
(RIGHT-HAND SINGLE DOOR)
STRAIGHT CUT TOP & BOTTOM
EDGE.
3'-0"
4"
W318
5'-0"
PREP
HOLLOW METAL
FRAME
PAINT PT-33
2'-6"
FRP AS SCHEDULED
E
F
G
A2.0
3/18/2010 1:58:02 PM
SERVICE
3'-0"
JYOU
FRP AS SCHEDULED
FRP AS SCHEDULED
ITEM #
DESCRIPTION
MANUFACTURER
SPECIFICATION
SIZE
GROUT
FURN INSTALL
PSW SPEC
REQD
COMMENTS
FLOORING
FT01
FT02
FT03
FT04
QUARRY TILE
QUARRY TILE (ALTERNATE)
PORCELAIN TILE
DALTILE
DALTILE
DALTILE
OQ84-RED PAVER - SMOOTH; SKU #OQ84661PB
OQ81 - RED PAVER - SURETREAD; SKU #0Q81661PB
KEYSTONE D317; 1" BISCUIT PORCELAIN HEXAGON SKU #D3171HEXMS1P
KEYSTONE D311; 1" BLACK PORCELAIN HEXAGON SKU #D3111HEXMS1P
6" X 6"
6" X 6"
1" X 1'
LATICRETE #45 RAVEN
LATICRETE #45 RAVEN
LATICRETE #45 RAVEN
GC
GC
GC
ALTERNATE TO BE USED ONLY IF REQ'D BY LOCAL JURISDICTION; CONTACT:
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
GC
FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY
NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
GC
FOR ENTRY VESTIBULE & RESTROOMS AS PER DRAWINGS; REFERENCE POTBELLY
NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
DALTILE
FT05
CONCRETE TOPPING
DIAMOND GRIND SURFACE W/ A PLANETARY HEAD DIAMOND GRIND SYSTEM.
SCORE CUT SYSTEM AND INSTALL WITH MONGOOSE DECORATIVE SCORE CUT
SCOFIELD CONCRETE SEALANT SAW SYSTEM. APPLY 2 COATS OF SEALANT.
3' X 3' SCORING WITH
1/8"W X 1/8"D. MAX.
NA
GC
GC
CAULK ALL EXPANSION JOINTS. REFER TO ARCHITECTURAL SPECIFICATIONS &
CONSTRUCTION MANUAL FOR COMPLETE SPECIFICATIONS.
FT06
PORCELAIN TILE
ERGON
24" X 24"
LATICRETE #45 RAVEN
GC
GC
CONTACT: MICHAEL MONTORSI (630) 539-4470 OR [email protected]
FT07
WOOD PLANK
1 1/2" FACE STAGGERED
NA
GC
GC
FT11
CONCRETE FLOOR TOPPER/FILLER
MAPEI
PLANITOP X REPAIR MORTAR
NA
NA
GC
GC
FOR USE ON EXISTING CONCRETE SURFACES IN NEED OF REPAIR. REFER TO
CONSTRUCTION MANUAL FOR FURTHER INFORMATION.
FT12
LUXURY VINYL TILE (LVT)
AMTICO
AROSMS43 STRIA BASALT
18" X 18"
NA
GC
GC
USE MANUFACTURER RECOMMENDED ADHESIVE AND INSTALLATION METHOD.
CONTACT RACHEL STOCKARD FOR PRICING 630-335-0939
FT16
WALK OFF MAT
IMPACT SPECIALTIES
HELIX Z-1 TILE, BLACK WITH BLACK FRAME
12" X 9"
NA
GC
GC
CONTACT LOCAL IMPACT SPECIALTIES REPRESENTATIVE, CONTACT JENNY MCCARTHY
FOR PRICING 312.859.3689
FT17
PORCELAIN TILE
ERGON
ARCHITECT RESIN, HONGKONG TAUPE 809G7R
32"X32"
LATICRETE #45 RAVEN
GC
GC
FT18
PORCELAIN TILE
DALTILE
VERANDA TONES, REDLAND HILLS P531 SKU #P5016531P
6.5" X 20"
LATICRETE #45 RAVEN
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
GC
INTEGRAL COVE BASE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT WHEN
ORDERING (P): 877.556.5728 ; (E): [email protected]
GC
GC
INTEGRAL COVE BASE; CAULK BASE AT FLOOR MATERIAL; CONTACT: REFERENCE
POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
VD
GC
ECOLOGIK GRIGIO
GC
GC
PORCELAIN TILE
1" X 1"
LATICRETE #45 RAVEN
GC
STANDARD FLOOR TILE AT SERVICE LINE & BOH; CONTACT: REFERENCE POTBELLY
NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
GENERAL NOTES
A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR
ELEVATIONS FOR EXACT FINISHES.
B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS.
C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE
WR01 PRIOR TO APPLYING FINISHED MATERIAL.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
D. REFER TO SHEET A1.2 FOR CEILING HEIGHTS.
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
CONTACT: MICHAEL MONTORSI (630) 539-4470 OR [email protected]
DALTILE
P-3665 0W81 RED PAVER COVE BASE SKU #0Q81P3365F1PB
4 1/4" X 6"
6" X 6"
LATICRETE #45 RAVEN
GC
WB02
CERAMIC TILE BASE
DALTILE
ROUND TOP COVE BASE #S-3419T; BLACK K111 SEMI-GLOSS SKU
#K111S3419T1P1
WB03
WOOD BASE & SHOE
RETAIL FIXTURES
CASEWORK ITEM #W306 WITH CASEWORK ITEM #W307
5/8" X 5 1/4"
WB04
WOOD BASE
RETAIL FIXTURES
CASEWORK ITEM #W325
1" x 4"
NA
VD
GC
WB05
CERAMIC BASE (BATHROOM)
DALTILE
COLOUR SCHEME PC36C9TB, UPTOWN TAUPE B904 SKU #B904PC36C9TB1P2
6" X 12"
LATICRETE #18 SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WB06
CERAMIC BASE (CASEWORK)
DALTILE
VERANDA SOLIDS, GRAVEL P501 SKU #P50165201P
6-1/2" X 20"
LATICRETE #45 RAVEN
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WB07
PORCELAIN TILE
DALTILE
VERANDA SOLIDS, RAWHIDE P525
6-1/2" X 20"
LATICRETE #43 CHOCOLATE
TRUFFLE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
DALTILE
COLOR:GARDEN SPOT #0141; SEMI-GLOSS SKU #014136MOD1P2
3" X 6"
LATICRETE #45 RAVEN
GC
GC
CUSTOM ORDER TILE. ALLOW 4 WEEKS. CONTACT: REFERENCE POTBELLY NATIONAL
ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E): [email protected]
3" X 6"
LATICRETE #45 RAVEN. IF
REQ'D BY CODE USE #18
SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
LATICRETE #45 RAVEN
WALLS
WT01
NOT USED
WT02
CERAMIC TILE
CERAMIC TILE
DALTILE
COLOR: BISCUIT K175, SEMI-GLOSS SKU #K17536MOD1P4
2" X 6"
LATICRETE #45 RAVEN
GC
GC
BULLNOSE ALONG 6" EDGE; CONTACT: REFERENCE POTBELLY NATIONAL ACCOUNT
WHEN ORDERING (P): 877.556.5728 ; (E): [email protected]
WT04
CERAMIC TILE
DALTILE
BULLNOSE S-4269; COLOR: BLACK K111, SEMI-GLOSS SKU #K111S42691P2
WT06
CERAMIC TILE
DALTILE
BLACK QUARTER ROUND A106; COLOR BLACK K111, SEMI-GLOSS SKU
#K111A1061P2
3/4" X 6"
LATICRETE #45 RAVEN
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WT07
MOSAIC TILE
PSW-HUBBARD
1"X1" CUSTOM MOSAIC TILE
1" X 1"
TBD
PSW
GC
REFER TO DRAWINGS
WT10
CERAMIC TILE (BULLNOSE BACKLINE)
DALTILE
RITTENHOUSE SQUARE, S-4369, COLOR: BISCUIT K175 SEMI-GLOSS SKU
#K175S4369MOD1P2
3" X 6"
LATICRETE #18 SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WT11
GLASS TILE (CHIP CUBBIE)
DALTILE
ISIS GLASS MOSAICS, CANDY APPLE RES IS19 SKU #IS1911MS1P
1" X 1" (12" X 12" SHEETS)
LATICRETE #18 SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WT12
CERAMIC TILE (CHIP CUBBIE)
PSW-HUBBARD
CUSTOM MOSAIC TILE
TBD
TBD
VD
GC
CONTACT ROCKWELL (POTBELLY WAREHOUSE) 312.279.0107
5/8" X 3"
LATICRETE #18 SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WT13
MOSAIC TILE
DALTILE
FASHION ACCENTS, ILLUMINI LAKE F015 SKU # F015583MS1P
WT14
MOSAIC TILE
DALTILE
FASHION ACCENTS, ILLUMINI LAKE F011 SKU #F0115858MS1P
5/8" X 5/8"
LATICRETE #18 SAUTERNE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WT15
PORCELAIN TILE
DALTILE
TERRACE, CHERRY P104 SKU #P1046361P
6"X36"
LATICRETE #43 CHOCOLATE
TRUFFLE
GC
GC
REFERENCE POTBELLY NATIONAL ACCOUNT WHEN ORDERING (P): 877.556.5728 ; (E):
[email protected]
WC01
CUSTOM WALLCOVERING
VARIES
PSW
GC
WC02
CUSTOM WALLCOVERING
VARIES
PSW
GC
WC03
CUSTOM WALLCOVERING
VARIES
PSW
GC
WR01
RANDOM TROWEL TEXTURE
GC
GC
FRP-01
FIBERGLASS REINFORCED PLASTIC
PANELS
GLASLINER (OR SIMILAR)
1200 SERIES; .090" THICKNESS; COLOR: WHITE TEXTURED
4' X 8' (OR 10')
GC
GC
CL01
ACOUSTIC CEILING TILE
ARMSTRONG
CLEAN ROOM VL#870- WHITE, WITH 15/16" METAL SUSPENSION GRID
24" X 48"
NA
GC
GC
CL06
STAMPED METAL LAY-IN PANEL
TIN MAN
12-10 VICTORIAN (LARGE)
24" X 24"
NA
VD
GC
CL07
STAMPED METAL LAY-IN PANEL
TIN MAN
VICTORIAN (SMALL)
24" X 24"
NA
VD
GC
ARMSTRONG OR EQUAL
15/16" ALUMINUM SUSPENDED CEILING GRID TO BE PAINTED WITH RUSTOLEUM
BRIGHT COAT METALLIC FINISH , ALUMINUM 7715-830
NA
GC
GC
DRYWALL MUD APPLIED TO WALL SURFACE WITH 8" FLAT TROWEL KNIFE. LIGHT
STUCCO THICKNESS. USE RANDOM PATTERN TO MATCH PSW SAMPLE
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
REFER TO DRAWINGS FOR HEIGHT. SEAL ALL EDGES & MOULDINGS
CEILING
PAINTED LAY-IN CEILING GRID
SHEET TITLE
COUNTERTOPS
CN01
SOLID SURFACE
CORIAN
SAHARA - POLISHED FINISH
REFER TO MILLWORK
DRAWINGS
NA
VD
GC
CN02
GRANITE COUNTERTOPS
QUADRO
SKU #142855
49" W X 3/4" TH W/ OGEE
EDGE
NA
GC
GC
CN03
SOLID SURFACE
LG
MACCHIATO- POLISHED FINISH
REFER TO MILLWORK
DRAWINGS
VD
GC
FOUND AT HOME DEPOT
FINISH
SCHEDULE
JYOU
CL08
CUT COUNTERTOP TO FIT, V.I.F. UNDERMOUNT BOWL
SHEET NUMBER
PAINTS
PT01
PAINT
BENJAMIN MOORE NATURA
AC-2 BERKSHIRE BEIGE - EGGSHELL FINISH
GC
GC
PT02
PAINT
BENJAMIN MOORE NATURA
AC-17 SEA PINE - SEMI-GLOSS FINISH
GC
GC
PT03
PAINT
BENJAMIN MOORE NATURA
1267 RUBY DUSK - EGGSHELL FINISH
GC
GC
A2.1
3/17/2010 5:34:34 PM
WT03
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.1 FINISH SCHEDULE.DWG
QUARRY TILE BASE
PROJECT NUMBER: 16-059
WB01
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
BASE
PT04
PAINT
BENJAMIN MOORE NATURA
944 ALBANY WHITE - EGGSHELL FINISH, SEMI-GLOSS FINISH FOR CEILING
GC
GC
GC
GC
PT05
PAINT
BENJAMIN MOORE NATURA
2160-40 ROASTED SESAME SEED - EGGSHELL FINISH; SEMI-GLOSS IN TOILET
ROOMS
PT06
PAINT
BENJAMIN MOORE NATURA
2174-30 SEDONA CLAY- EGGSHELL FINISH
GC
GC
PT07
PAINT
BENJAMIN MOORE NATURA
HC-72 BRANCHPORT BROWN - EGGSHELL FINISH
GC
GC
GENERAL NOTES
A. FINISH MATERIALS VARY ON WALLS. REFER TO INTERIOR
ELEVATIONS FOR EXACT FINISHES.
B. NO SUBSTITUTIONS ALLOWED ON ANY SPECIFICATIONS.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
C. REFER TO PSW FURNISHED SAMPLE FOR TROWEL TEXTURE
WR01 PRIOR TO APPLYING FINISHED MATERIAL.
PT09
PAINT
BENJAMIN MOORE NATURA
2144-10 GUACAMOLE - EGGSHELL FINISH
GC
GC
PT10
PAINT
BENJAMIN MOORE NATURA
2120-10 JET BLACK - GLOSS - MARINE FINISH
GC
GC
D. REFER TO SHEET A1.2 FOR CEILING HEIGHTS.
A
R
4 0 4 S.
PT11
PAINT
BENJAMIN MOORE NATURA
HC-32 STANDISH WHITE - GLOSS FINISH
GC
GC
PT12
PAINT
BENJAMIN MOORE NATURA
HC-49 MAYFLOWER RED- EGGSHELL FINISH
GC
GC
PT13
NOT USED
PT14
PAINT
BENJAMIN MOORE NATURA
E-22 COTTAGE RED - GLOSS FINISH
GC
GC
PT15
PAINT
BENJAMIN MOORE NATURA
E-43 ESSEX GREEN - ENAMEL ALKYD HIGH GLOSS FINISH AT EXTERIOR;
EGGSHELL AT INTERIOR
GC
GC
PT16
PAINT
BENJAMIN MOORE NATURA
2165- 20 GOLDEN MEADOW - EGGSHELL FINISH
GC
GC
PT17
PAINT
BENJAMIN MOORE NATURA
1307 GERAMUM - EGGSHELL FINISH
GC
GC
PT18
PAINT
BENJAMIN MOORE NATURA
2103-20 ENGLISH MANOR- EGGSHELL FINISH
GC
GC
PT19
PAINT
BENJAMIN MOORE NATURA
AC-3 TEXAS LEATHER - EGGSHELL FINISH
GC
GC
PT20
NOT USED
PT21
PAINT
BENJAMIN MOORE NATURA
2020-10 BUMBLE BEE YELLOW - SEMI-GLOSS FINISH
GC
GC
SUBMARINE DUCT COLOR
PT22
PAINT
BENJAMIN MOORE NATURA
2021-50 YELLOW LOTUS - SEMI-GLOSS FINISH
GC
GC
SUBMARINE DUCT COLOR
PT23
PAINT
BENJAMIN MOORE NATURA
2145-20 TERRAPIN GREEN - SEMI-GLOSS FINISH
GC
GC
SUBMARINE DUCT COLOR
PT24
PAINT
BENJAMIN MOORE NATURA
2001-10 RUBY RED - SEMI-GLOSS FINISH
GC
GC
SUBMARINE DUCT COLOR
PT25
PAINT
BENJAMIN MOORE NATURA
HC-7 BRYANT GOLD - EGGSHELL FINISH
GC
GC
PT26
PAINT
BENJAMIN MOORE NATURA
2145-30 BROOKSIDE MOSS - EGGSHELL FINISH
GC
GC
PT27
PAINT
BENJAMIN MOORE NATURA
2062-20 GENTLEMAN'S GRAY - EGGSHELL FINISH
GC
GC
PT28
PAINT
BENJAMIN MOORE NATURA
HC-158 NEWBURG GREEN - EGGSHELL FINISH
GC
GC
PT29
PAINT
BENJAMIN MOORE NATURA
HC-136 WATERBURY GREEN - EGGSHELL FINISH
GC
GC
PT30
PAINT
BENJAMIN MOORE NATURA
2164-10 SADDLE BROWN - EGGSHELL FINISH
GC
GC
PT31
PAINT
BENJAMIN MOORE NATURA
692 - JACK PINE - EGGSHELL FINISH
GC
GC
PT32
PAINT
BENJAMIN MOORE NATURA
2118-40 SEA LIFE- EGGSHELL FINISH
GC
GC
PT33
PAINT
BENJAMIN MOORE NATURA
2107-10 CHOCOLATE CANDY BROWN - EGGSHELL FINISH
GC
GC
PT34
NOT USED
NOT USED
GC
GC
PT35
PAINT
BENJAMIN MOORE NATURA
2135-60 SUMMER SHOWER - SEMI-GLOSS FINISH
GC
GC
PT36
PAINT
BENJAMIN MOORE NATURA
2158-30 DELIGHTFUL GOLDEN - EGGSHELL FINISH
GC
GC
PT37
PAINT
BENJAMIN MOORE NATURA
2175-30 RUST - EGGSHELL FINISH
GC
GC
PT38
PAINT
BENJAMIN MOORE NATURA
2154-50 STRAW- SEMI-GLOSS
GC
GC
PT39
PAINT
BENJAMIN MOORE NATURA
1672 ALFRESCO- EGGSHELL FINISH
GC
GC
PT40
PAINT
BENJAMIN MOORE NATURA
697 SCENIC DRIVE- EGGSHELL FINISH
GC
GC
PT41
PAINT
BENJAMIN MOORE NATURA
007 PINATA
GC
GC
PT42
SPECIALITY PAINT
SCUFFMASTER
AMBIENT DESIGN, COLOR: TB102 (TO MATCH BM2144010)
GC
GC
REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
PT43
SPECIALITY PAINT
SCUFFMASTER
AMBIENT DESIGN, COLOR: TB101 (TO MATCH BMHC-158)
GC
GC
REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
PT44
SPECIALITY PAINT
SCUFFMASTER
AMBIENT DESIGN, COLOR: TB099 (TO MATCH BM2107-10)
GC
GC
REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS
PT45
NOT USED
PT46
PAINT
BENJAMIN MOORE NATURA
2062-40 BLUE DAISY - EGGSHELL FINISH
GC
GC
PT47
PAINT
BENJAMIN MOORE NATURA
2049-30 TEAL OCEAN - EGGSHELL FINISH
GC
GC
ST01
STAIN
SHERWIN WILLIAMS
S64WCY6378-4357
GC
GC
ST02
STAIN
SHERWIN WILLIAMS
S64WXN1482-4357
GC
GC
ST03
STAIN
SHERWIN WILLIAMS
S64WXN12787
GC
GC
ST04
STAIN
SHERWIN WILLIAMS
S61WCY6378-4357
GC
GC
ST05
STAIN
MINWAX
50:50 MIX; PROVINCIAL #211 & GOLDEN OAK #210B
GC
GC
ST06
STAIN
ZINSSER
AMBER SHELLAC; 00701 BULLS EYE
GC
GC
PROVIDE (3) COATS, SANDED BETWEEN. TYPICAL AT CEDAR PANELS & WALL PANELS AS
NOTED ON ELEVATIONS.
ST07
STAIN
MINWAX
TINTED POLYURETHANE; PRIME WITH PT-03, THEN (2) COATS POLYSHADES
BOMBAY MAHOGHANY - GLOSS FINISH
GC
GC
PROVIDE (3) COATS, SANDED BETWEEN.
ST08
STAIN
BEHR
#501 NATURAL CEDAR
GC
GC
PROVIDE (3) COATS - FOR EXTERIOR USE AT CEDAR PLANKS
ST09
STAIN
MINWAX
MEDIUM RED; 1:1 RATIO OF RED SEDONA #222, JACOBEAN #2750 & (2) COATS
AMER SHELLAC
GC
GC
ST10
STAIN
SHERWIN WILLIAMS
M64F533 TINT
GC
GC
ST11
PAINT
BENJAMIN MOORE NATURA
PAINT PT-10
GC
GC
ST12
STAIN
MINWAX
LIGHT; IPSWICH OR GOLDEN OAK
GC
GC
FURNITURE STAIN
ST13
STAIN
MINWAX
MEDIUM: PROVINCIAL OR MAHOGHANY
GC
GC
FURNITURE STAIN
ST14
STAIN
MINWAX
DARK; SPECIAL WALNUT OR EBONY
GC
GC
FURNITURE STAIN
ST-15
STAIN
MINWAX
DARK; WATER BASED OIL MODIFIED POLYURETHANE - ROYAL WALNUT
GC
GC
ST-16
STAIN
MINWAX
POLYSHADES BOMBAY MAHOGANY - SATIN FINISH
GC
GC
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ALL DOORS AND TRIM UNLESS NOTED OTHERWISE
PROJECT NUMBER: 16-059
NOT USED
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
PT08
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.2 FINISH SCHEDULE (CONT.).DWG
STAINS
FINISH
SCHEDULE
(CONT.)
JYOU
SHEET TITLE
BR01
FULL MODULAR BRICK
GLEN-GERY BRICK
4-HB MOLDED FACE BRICK - BURGUNDY RANGE (DARK ROSE) SAND TEXTURE
GC
GC
BR02
THIN BRICK
GLEN-GERY BRICK
ABERDEEN THIN BRICK WITH THIN BRICK CORNERS - BURGUNDY RANGE PAPERCUT TEXTURE
GC
GC
A2.2
10/9/2009 3:17:59 PM
SHEET NUMBER
BRICK
MODEL #
Count
EQUIPMENT SCHEDULE
FURN
FINISH
INSTALL
VOLTS
WATTS
AMP
PLUG
COMMENTS
E103
SLIDING DOOR ASSEMBLY W/ SHELVES
ARDCO
CUSTOM SHELVES - (7) FLAT STYLE ON 1" SLOPE W/O DIVIDERS
E105
REFRIGERATED FRONT LOAD STATION
TRUE
TPP-44D-2 W/ S/S BUMPER
1
300 SERIES S/S
VD
VD
120/1
8.6
5-15P
W/ 5" CASTERS.
E106
REFRIGERATED DRESS STATION
TRUE
TSSU-27-12M-C
3
300 SERIES S/S
VD
VD
120/1
4.9
5-15P
W/ 5" CASTERS.
E107
REFRIGERATED DRESS/SALAD STATION
RANDELL
9412-32D-7
2
S/S
VD
VD
120/1
5.5
5-15P
W/ 2 1/2" CASTERS.
E128
37" ICE-CREAM DIPPING CABINET
NELSON
6DIP
1
S/S & WHITE ENAMEL
VD
VD
115V
8
E130
WORKTOP REFRIGERATOR
TRUE
TUC-27
1
S/S
VD
VD
115/60/1
3.9
5-15P
CONFIRM HINGE SIDE, W/ SHAKE STATION MODIFICATION
E201
WALL SHELF ASSEMBLY - 42"
METRO
(2) 42" W DOUBLE TIER - METROSEAL WALL SHELVES WITH SMARTWALL COMPONENTS
2
GREEN EPOXY
VD
VD
18" D UPPER SHELF, 14" D LOWER SHELF - SEE ELEVATIONS FOR MOUNTING HEIGHTS. PROVIDE BLOCKING IN WALL.
E207
DRY STORAGE SHELVING W/ CASTERS- 48" W
FOCUS
SHELVES: FF1848G W/ 4 TIERS POSTS: FGN086G 86"H
4
GREEN EPOXY
VD
VD
INCLUDES CASTERS: FSCAST5
1
BLACK EPOXY
VD
VD
REFER TO PLAN FOR ROUGH OPENING DIMENSIONS- SEE VENDOR CUTSHEET FOR INFO
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
E208
MEATBALL WARMER WIRE SHELVING W/ CASTERS
FOCUS
SHELVES: FF1430C W/ 2 TIERS, (1) S/S FLAT SOLID SHELF POSTS: FGN033C 33"H
1
S/S
VD
VD
E209
SALAD SHELF
ELKAY
SSP TOP MOUNT SHELF FOR RANDELL UNIT
2
S/S
VD
VD
E210
WRAPPING PAPER SHELF
ELKAY
12 1/2" X 27 1/2" SHELF W/ DIVIDER & BRACKETS
3
S/S
VD
VD
E213
STAINLESS STEEL WALL SHELF- 24"
ADVANCE TABCO
WS-KD-24X
2
S/S
VD
VD
11 1/8"W X 2'
E215
MOBILE DUNNAGE RACK 48"
FOCUS
FFMDR1848GN 18" X 48" X 13.5 H"
1
GREEN EPOXY
VD
VD
USED AT WALK-IN FREEZER & BREAD BOX STORAGE
E219
CHEMICAL SHELF- 14" X 24"
FOCUS
SHELVES: FF1424G W/ 6 TIERS POSTS: FGN086G
1
GREEN EPOXY
VD
VD
COOLER SHELVING, INCLUDES CASTERS: FSCAST5
E221
WALK-IN WIRE STORAGE SHELF- 18" X 36"
FOCUS
CAMSHELVING ELEMENTS SERIES 36" - ESK1836V W/ 4 TIERS; POSTS: EPK1872
4
POLYPROPYLENE
VD
VD
COOLER SHELVING, INCLUDES CASTERS: FSCAST5
E222
WALK-IN WIRE STORAGE SHELF- 18" X 42"
FOCUS
CAMSHELVING ELEMENTS SERIES 42" - ESK1842V W/ 4 TIERS; POSTS: EPK1872
2
POLYPROPYLENE
VD
VD
COOLER SHELVING, INCLUDES CASTERS: FSCAST5
E223
WALK-IN WIRE STORAGE SHELF- 18" X 48"
FOCUS
CAMSHELVING ELEMENTS SERIES 48" - ESK1848V W/ 4 TIERS; POSTS: EPK1872
1
POLYPROPYLENE
VD
VD
COOLER SHELVING, INCLUDES CASTERS: FSCAST5
E226
OVEN STAND - TURBOCHEF
ELKAY
CUSTOM - 42" X 31"
2
S/S
VD
VD
TO BE USED WITH E304/E304A
E247
DRYING WALL SHELF ASSEMBLY - 42"
METRO
(2) 42" W DOUBLE TIER - METROSEAL WALL SHELVES WITH SMARTWALL COMPONENTS
2
GREEN EPOXY
VD
VD
AT 3 COMP SINK ONLY. 18" D UPPER SHELF, 14" D LOWER SHELF - SEE ELEVATIONS FOR MOUNTING HEIGHTS. PROVIDE BLOCKING IN WALL.
E248
BUN PAN RACK
CHANNEL MANUFACTURING
401AC
2
ALUM
VD
VD
E250
MOBILE CART
FOCUS
21" x 30"
2
S/S
VD
VD
E251
SUPPORT SHELF
FOCUS
21" x 30"
1
SS
VD
VD
E252
DUNNAGE RACK AT SODA 36"
FOCUS
24" x 36" FF2436C SHELF, 7" FG007C STATIONARY POSTS
1
SS
VD
VD
E302
MEATBALL WARMER
VOLLRATH
72051
1
S/S
VD
VD
120/1
1600
13.3
5-15P
WITH DRAIN
E302A
MEATBALL WARMER FOR SOUP
VOLLRATH
72051
1
S/S
VD
VD
120/1
1600
13.3
5-15P
WITH DRAIN
E304
CONVEYER OVEN - HIGH HEAT (REGULAR)
TURBOCHEF GLOBAL OPERATIONS
HIGH h CONVEYER 2020
2
S/S
VD
VD
208/240
50
UL 4 PIN
PLUG TO BE 60 AMP
E401
SLICER
BERKEL INC.
X13AE
1
VD
VD
115/60/1
7
E402
CAN OPENER
EDLUND
1S
1
S/S
VD
VD
SECURE TO UNDERSIDE OF TABLE
E403
SCALE
EDLUND
DS SERIES II- DS-10-PB #53300
3
S/S
VD
PSW
115V AC ADAPTER INCLUDED
E404
FAX MACHINE
BROTHER
MFC-7440N
1
VD
VD
COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT FOR EXISTING STORES
E405
SAFE
CORPORATE SAFE SPECIALISTS
B3121DM
1
VD
VD
E406
POS
RADIANT SYSTEMS
P1520
3
VD
VD
COORDINATE INSTALL WITH RTG FOR NEW STORES, PSW IT SUPPORT FOR EXISTING STORES
E409
SODA RACK & CARBONATOR
PROFITMASTER DISPLAYS, INC.
BIB FLEX RACK SYSTEM, 28" W X 16" D X74" H, ITEM #44239 WITH WALL MOUNT ITEM #44249
1
VD
VD
BAG IN THE BOX RACK
E410
CO2 TANK
1
VD
VD
GC TO PROVIDE AND INSTALL 4'-0" STRAIGHT LINK CHAIN #4 SIZE AND COMBO PAD LOCK
E427
COUNTER MOUNTED BLENDER
2
VD
VD
ITEM #
DESCRIPTION
MANUFACTURER
FURNITURE SCHEDULE
Count
FINISH
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PROVIDE (3) WILDSIDE JARS & (3) RED SPATULAS PER BLENDER
MODEL #
I
ILLINOIS DESIGN FIRM # 184.006688
W/ SLAW TRAY
15
S t .,
FURN
INSTALL
COMMENTS
F100
24" X 28" TABLE
RETAIL FIXTURE
2
ST-12
VD
GC
F101
24" X 28" TABLE
RETAIL FIXTURE
3
ST-13
VD
GC
F102
24" X 28" TABLE
RETAIL FIXTURE
3
ST-14
VD
GC
F107
34" X 34" TABLE
PSW-HUB
1
CUSTOM
PSW-HUB
GC
F108
28" X 46" TABLE
RETAIL FIXTURE
1
ST-12
VD
GC
F109
28" X 46" TABLE
RETAIL FIXTURE
2
ST-13
VD
GC
F110
28" X 46" TABLE
RETAIL FIXTURE
1
ST-14
VD
GC
F112
24" ROUND TABLE
PSW-HUB
2
CUSTOM
PSW-HUB
GC
F113
30" ROUND TABLE
PSW-HUB
1
CUSTOM
PSW-HUB
GC
F115
42" ROUND TABLE
PSW-HUB
1
CUSTOM
PSW-HUB
GC
F117
STAND UP COUNTER
RETAIL FIXTURE
1
ST-13
VD
GC
F121
OUTDOOR TABLE (WI) - 30"
FOUR SEASONS
PB-WITABLE-30
6
BLACK WROUGHT IRON
VD
GC
F200
SHORT CAST IRON BASE
BARN FURNITURE
DRDFDS24
9
BLACK WRINKLE WROUGHT IRON
VD
GC
F201
HIGH BAR BASE - 30"
BARN FURNITURE
DRDHC3030BH
4
BLACK WRINKLE
VD
GC
STANDARD HIGH BASE- 30 x 30" cross base with bar height column
F203
ADA LEGS
BARN FURNITURE
DRDHC2205
1
BLACK
VD
GC
SET OF 2, TYPICAL AT ADA TABLE
F206
HIGH SINGLE PIPE W/ WALL CLEAT
RETAIL FIXTURE
3
BLACK
VD
GC
BASE FOR HIGH TOP 28 X 46 OR ALONG WALL
F300
CHAIR - INDOOR
BARN FURNITURE
SCHOOLHOUSE CH3004
17
MEDIUM FINISH
VD
GC
F301
BARSTOOL
BARN FURNITURE
SCHOOLHOUSE ST3004
30
MEDIUM FINISH
VD
GC
F302
OUTDOOR CHAIR (WI)
FOUR SEASONS
PB-WICHAIR
12
BLACK WROUGHT IRON
VD
GC
F304
CUSTOM BENCH
PSW-HUB
1
CUSTOM
PSW-HUB
GC
F407
OUTDOOR TRASH RECEPTACLE
FOUR SEASONS
2
BLACK POWDER COATED
VD
GC
F500
DECORATIVE STOVE
CUSTOM POTBELLY HERITAGE ITEM
1
CUSTOM
PSW-HUB
PSW
F501
STANCHION
PSW-HUB
3
WROUGHT IRON
PSW-HUB
GC
F502
CHAIN AT STANCHION
PSW-HUB
2
METAL
PSW-HUB
GC
SHEET TITLE
F503
CUSTOM BUILT SUBMARINE
GC
1
PAINT PT21, PT22, PT23, PT24
GC
GC
FF & E
SCHEDULES
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.3 FURNITURE FIXTURE & EQUIPMENT
SCHEDULES.DWG
A1-48Q-43S SMOOTHER Q15 WILDSIDE
CHROME
H
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
BLENDTEC
HAMMER-TONE
INCLUDES: 1430FS, FGN033C & FSCAST5
C
Wells
SEE PLAN A1.4 FOR LENGTH
ALL EXPOSED FASTENERS TO BE PAINTED BLACK
JYOU
MANUFACTURER
SHEET NUMBER
A2.3
3/15/2010 2:14:11 PM
DESCRIPTION
PROJECT NUMBER: 16-059
ITEM #
FURN.
INSTALL
COMMENTS
Name
DESCRIPTION
MANUFACTURER
PRODUCT #
Count
FINISH
FURN. INSTALL
COMMENTS
M103
CUP DISPENSER
SAN JAMAR
C2410C18
3
VD
VD
GC
M104
MOP/BROOM HANGER
CARLISLE
4073100
1
VD
VD
PSW
GC
M106
BREAD BIN
ELKAY
54"L X 10 1/2"W, SLOPED TOP/OPENING
1
S/S
VD
VD
48" x 72"
PSW
GC
M107
KNIFE RACK
EDLUND
KR-700
2
S/S
VD
VD
36" x 55"
PSW
GC
M109
30" WORK TABLE W/ CASTERS
ELKAY
24"D X 30"L
1
S/S
VD
VD
INCLUDES 5" CASTERS
2
PSW
GC
M111
CORNER GUARD
ADE
U SHAPE OR L SHAPE - 42"H AT FRP / 57"H AT TILE
3
S/S
VD
VD
INSTALLED PER PSW LOCATIONS ON DWGS
HANDICAPPED TOILET ROOM SIGN
2
GC
GC
M112
COAT RACK
EX-CELL
700-SA - 6 HOOK
2
ALUM
VD
VD
PSW
11 X 17 CHALKBOARD SIGN
1
17" X 11"
PSW
GC
M113
PAN RACK
NEW AGE
98485
2
ALUM
VD
VD
S212A
PSW
WALLPAPER "OFFERINGS" PANELS
2
43" x 14"
PSW
GC
LOCATED AT BACKLINE CABINETS
M114
CUTTING BOARD / SINK COVER
SAN JAMAR
1
WHITE POLY
VD
VD
S213
PSW
COMMUNITY BOARD
1
VARIES
PSW
GC
CHOOSE 38"X38" OR 56"X27"
M115
CUTTING BOARD - PREP ROOM
SAN JAMAR
CB182412WH
1
WHITE POLY
VD
VD
PROVIDE POWER AT 96" OR AS INDICATED ON
ELECTRICAL DWGS. DESIGN MGR TO SPECIFY VERTICAL
(26X43) OR HORIZONTAL (43X26)
M121
SLICER SLAW TRAY
BERKEL INC.
3875-00241
1
VD
VD
M123
MEATBALL WARMER PANS
VOLLRATH
30043, 30362, 75220 & 75230
4
VD
VD
PSW
PSW
GC
GC
S100
SIGN VENDOR
LOGO WALL SIGN
2
S201
PSW
SOUP/SHAKE MENU BOARD
1
S202
PSW
DESSERT MENU BOARD
S203
PSW
S204
VD
VD
28 1/2"X 31"
PSW
1
31"X 56 1/2"
MENU BOARD - LARGE
1
PSW
MENU BOARD - MEDIUM
1
S207
PSW
CLEANING CHECKLIST
S208
GC
S209
INTERNALLY ILLUMINATED
LOCATED IN RESTROOMS
S/S
S216A
PSW
YA GOTTA GET IT HOT' SIGN - VERTICAL
1
VARIES
PSW
GC
S218
PSW
HANGING 'PHONE AHEAD' ARROW
1
24" X 24"
PSW
GC
M131
GARBAGE TOTE - EXTRA-LARGE
RUBBERMAID
9W2700-GY
1
S219
PSW
ORDER HERE FINGER SIGN
1
14 1/2" X 35"
PSW
GC
M135
EMPLOYEE LOCKER
GLOBAL INDUSTRIES
PENCO VANGUARD LOCKER SIX TIER, #WG480954GY
1
M136
COOLER CURTAIN
CURTON PRODUCTS
M-108-PR-4080
1
VD
VD
S220
RETAIL FIXTURE
HANGING MARKETING SIGN
1
29" X 47"
VD
GC
M138
TICKET RAIL
SAN JAMAR
CK6536A
1
VD
VD
S221
PSW
OUR SANDWICHES SIGN
1
23 3/4" X 18"
PSW
GC
M141
AUTOMATIC SOAP DISPENSER
POWERFOAM
PUSH AT HAND SINKS
2
VD
VD
S222A
PSW
VINYL STORE HOURS - 24"
2
PSW
GC
M142
SAFE BASE
CORPORATE SAFE SPECIALIST
2820-4
1
VD
VD
S223
PSW
VINYL WINDOW MARKETING MESSAGE
1
PSW
GC
M143
PAPER TOWEL DISPENSER - AUTOMATIC
TORK
H1 MATIC SYSTEM 551028A BLACK
4
MOLDED PLASTIC
VD
VD
S224
PSW
VINYL SANDWICH MAKERS ONLY SIGN
1
PSW
GC
M145
4"H BACKSPLASH
CUSTOM
CUSTOM - 4"HX27"L 18GA. S/S BACKSPLASH
1
S/S
VD
VD
PSW
VINYL TOILET ROOM DOOR SIGNS - MEN &
WOMEN
2
PSW
M146
SINGLE TOPPING STATION DRY PRODUCT
DISPSENSER
SERVER PRODUCTS
87215 W/ 87217 WALL MOUNT BRACKET, 87199 1/9 SIZE JAR:
CLEAR, 87253 HINGE LID: CLEAR, 81516 SERVING SPOON: CLEAR
1
S/S
VD
VD
M147
PUMP RAIL COMBO
SERVER PRODUCTS
SR-3 82870 W/ 82120 S/S PUMPS AND 82557 JARS
1
SS
VD
VD
M148
CUP & LID ORGANIZER
DISPENSE-RITE
LID-3BT
2
POLY
VD
VD
M149
STRAW HOLDER
DISPENSE-RITE
MSH-1
2
ACRYLIC
VD
VD
M150
DRAINER BOARD
SSP, INC.
CUSTOM - 12"W X 12"D
1
VD
VD
M151
HANDS FREE SOAP DISPENSER
POWERFOAM
AUTOMATIC AT TOILET ROOMS
2
BLACK
VD
VD
3
S/S
VD
VD
S225
CEILING MOUNTED; PROVIDE POWER AT CEILING- FLUSH
OUTLET AT TIN CEILING; SPOTLIGHT AT OPEN CEILING
GC
STEEL, COLOR: GRAY
BLACK
S300
PSW
ORDER YOUR SHAKE NOW SIGN
1
29" X 19"
PSW
GC
S301
PSW
PICKLE SIGN
1
9" X 5"
PSW
PSW
S302
PSW
EMPLOYEES MUST WASH HANDS SIGN
4
6.5" X 8"
PSW
GC
S303
PSW
ADA ASSISTANCE SIGN WITH BELL
1
9" X 11.5"
PSW
GC
S304
PSW
NEED ASSISTANCE STROLLER/ADA SIGN
1
12" X 15"
PSW
GC
S305
PSW
THANKS FOR YOUR BUSINESS SIGN
1
21" X 27"
PSW
GC
S306
PSW
CHIPS PRICE SIGN
1
12" X 1.25"
PSW
GC
M154
DRESS STATION RISER SHELF
SPOKANE STAINLESS
PRODUCTS
S307
PSW
COUNTERTOP MARKETING PIPE SIGN
1
22" X 11"
PSW
PSW
M155
BEVERAGE GLIDES
ADE
CUSTOM MODEL NO. RTC
1
VD
VD
S308
PSW
HOT PEPPERS PRICE SIGN
1
5" X 7"
PSW
PSW
M156
STAINLESS STEEL TABLE 36" ON
CASTERS
ELKAY FOODSERVICE
PRODUCTS
WT36S36-BS - 36"D X 36"
1
VD
VD
S309
PSW
HAND SANITIZER STAND AND SIGN
1
9" X 60"
PSW
GC
M200
MIRROR
PSW-HUBBARD
CUSTOM
2
PSW
GC
S310
PSW
FOUNTAIN CUP/LID HOLDER
1
16.5" X 5.5"
PSW
PSW
M201
3'-6" HORIZONTAL GRAB BAR
BOBRICK
B-6806 SERIES
2
S/S
GC
GC
S311
PSW
LUNCH BOX COOKIE HOLDER
1
6" X 10" X 12"
PSW
PSW
M202
3'-0" HORIZONTAL GRAB BAR
BOBRICK
B-6806 SERIES
2
S/S
GC
GC
S312
PSW
DESSERT RISER
1
18 X 8 X 19
PSW
PSW
M203
1'-6" VERTICAL GRAB BAR
BOBRICK
B-6806 SERIES
2
S/S
GC
GC
S313
PSW
A-FRAME - EXTERIOR SIGN
1
49"x29"
PSW
GC
M204
DOUBLE ROLL TOILET TISSUE DISPENSER
BOBRICK
B-2740
2
CHROME
VD
VD
S314
PSW
A-FRAME TOPPER
1
24" X 17"
PSW
GC
M205
BABY CHANGING TABLE
KOALA KARE
KB200
2
CREAM
GC
GC
S315
PSW
A-FRAME CHALKBOARDS
1
22.5" X 37"
PSW
GC
M206
COAT HOOK
BOBRICK
B-6707
2
S/S
VD
VD
S316
PSW
P&H CUTTING BOARD
1
17" X 9"
PSW
GC
M207
TRASH CAN
2
CHROME
PSW
PSW
S317
PSW
FOUNTAIN DRINK PRICE HOLDER
1
11" X 6.25"
PSW
GC
M209
SANITARY NAPKIN DISPOSAL
1
SS
VD
VD
S318
PSW
STOVE PLAQUE
1
9" X 6"
PSW
GC
S319
PSW
COFFEE CONDIMENT RISER AND SIGN
1
10.5 X 38 X 22
PSW
PSW
S320
PSW
KIDS MENU
1
13" X 18.5"
PSW
GC
S321
PSW
PROMISE SIGN SQUARE
1
28"X28"
PSW
GC
S322
PSW
PROMISE SIGN HORIZONTAL
1
32"X18"
PSW
GC
S323
PSW
PROMISE SIGN VERTICAL
1
18"X32"
PSW
GC
S324
PSW
A WRECK
1
23"x19" framed
PSW
GC
S325
PSW
EXTRAS
1
19"x23" framed
PSW
GC
S326
PSW
SAVE TIME BEAT THE LINE
1
23"x19" framed
PSW
GC
S327
PSW
COOKIES POSTER
1
15"x21" framed
PSW
GC
S328
PSW
SHAKES POSTER
1
27"x33" framed
PSW
GC
S329
PSW
DELICIOUS SIGN - LARGE
1
8' LONG
PSW
GC
S330
PSW
DELICIOUS SIGN - SMALL
1
4' LONG
PSW
GC
S331
PSW
PEACE, LOVE & POTBELLY SIGN - LARGE
1
8' LONG
PSW
GC
S332
PSW
PEACE, LOVE & POTBELLY SIGN - SMALL
1
4' LONG
PSW
GC
S333
PSW
OUR SANDWICHES ARE SO GOOD
1
20" x 11"
PSW
GC
S334
PSW
KEEP AMERICA BEAUTIFUL
1
12" x 10"
PSW
GC
S335
PSW
GREEN STATEMENT PLAQUE
1
10.5" x 17"
PSW
GC
S336
PSW
CHECK OUT OUR DRIVE THRU
1
16" X 20"
PSW
GC
S337
PSW
START HERE SIGN
1
8" X 40"
PSW
GC
S338
PSW
AMERICAN FLAG
1
60" X 36"
PSW
GC
PLACED OUTSIDE IN FRONT OF STORE- MOVEABLE
BOBRICK
B-270
INCLUDES S/S BACK PLATE & 14" SKIRT
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
USED WITH ITEM #P204
12X12X 78; 6 OPENINGS. MAY SUBSTITUTE.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PLACE ON POTBELLY STOVE W/ PROVIDED CHAIN
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.4 FURNITURE FIXTURE & EQUIPMENT
SCHEDULES (CONT.).DWG
DIMS.- HxW
SHEET TITLE
FF & E
SCHEDULES
(CONT)
JYOU
Count
SHEET NUMBER
A2.4
3/15/2010 2:14:44 PM
DESCRIPTION
PROJECT NUMBER: 16-059
MANUFACTURER
MISCELLANEOUS
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ITEM #
SIGNAGE SCHEDULE
Count
FINISH
FURN.
INSTALL
P102
WATER CLOSET-FLO WISE WITH AUTOMATIC FLUSH
AMERICAN STANDARD
MADERA FLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067
HARD WIRED SELECTRONIC FLUSH VALVE (P104)
2
WHITE
GC
GC
P201
THREE COMPARTMENT SINK
ELKAY
3C16X20 - 2 - 18X, 20"D X 88"L, 10"H REAR SPLASH, LEFT & RT
HAND 18" DRAINBOARDS
1
SS
VD
GC
P204
STAINLESS STEEL WORKTABLE W/ SINK - PREP TABLE
ELKAY
SLWT30X84BS
1
SS
VD
P205
MOP SINK W/ FAUCET
FIAT
MOLDED STONE INTEGRAL DRAIN MSBID2424 W/ 830AA
SERVICE FAUCET
1
WHITE
P206
FLOOR SINK
SIOUX MANUFACTURING
861-23X W/ HALF GRATE 861-52i
P208
FLOOR DRAIN
SIOUX MANUFACTURING
P210
WALL-HUNG LAVATORY
AMERICAN STANDARD
VOLTS
PLUMBING SCHEDULE
WATTS
AMP
PLUG
HW. SUPPLY CW. SUPPLY
TW. SUPPLY
WASTE
VENT
PROVIDE WITH 5905.100 HEAVY DUTY AMERICAN STANDARD SEAT, FLUSH VALVE #6065.121.002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE
POWER.
1"
4"
3/4"
3/4"
(3) 2"
INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET
GC
3/4"
3/4"
1-1/2"
PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #P601 FOR FAUCET
GC
GC
1/2"
1/2"
3"
2"
4
GC
GC
3"
2"
842-3-P-NQ
6
GC
GC
3"
2"
LUCERNE 0355.012
2
VD
GC
WHITE
2"
COMMENTS
1/2"
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
VACUUM BREAKER
PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TRAP
SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE.
A
R
4 0 4 S.
HAND SINK
ELKAY
SEHS-17X - 17"L X 15"W X 5"D W/ SIDE SPLASHES
2
P215
SHAKE STATION (RIGHT HAND VERSION)
ELKAY
CUSTOM BACK BEVERAGE COUNTER
P401
CHEMICAL DISPENSER
CHEMICAL DISPENSER
P405
HOSE BIB
P406
SS
VD
GC
1/2"
1
VD
VD
1/2"
PROVIDE TEMPERING VALVE
1629WML/1629WMR
2
VD
VD
1/2"
CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR
WOODFORD
#17
1
GC
GC
TEMPERING VALVE
LEONARD
220
4
GC
GC
P408
BUILT-IN DIPPERWELL
T&S BRASS
006678-45 W/ B2282-F03
1
SS
VD
VD
P409
RINSER
BLENDTEC
JRE-610 LITTLE BLACK RINSER
1
SS
VD
VD
P410
TEA BREWER
BUNN
TB3Q
1
VD
VD
P600
3 COMP SINK FAUCET
T&S BRASS
B-0230-LN FAUCET; 064X 16" SWING NOZZLE W/ STREAM
REGULATOR
1
VD
GC
1/2"
1/2"
P601
PREP TABLE SINK FAUCET
T&S BRASS
B-0225-LN FAUCET; 135X 12" SWIVEL GOOSENECK
1
VD
GC
1/2"
1/2"
P603
HAND SINK FAUCET
T&S BRASS
B-1115-LN FAUCET; 131X SWING GOOSENECK; 1136-45 TEFLON
SEAT WASHERS
2
BRONZE
VD
GC
1/2"
1/2"
P605
SPRAYER NOZZLE
T&S BRASS
B-0133 W/ 063X, B-0155-LNEZ & B-0970-FEZ
1
CHROME
VD
GC
1/2"
P610
SHAKE STATION FAUCET & TEMPERING VALVE
T&S BRASS
B-0306
1
CHROME
VD
VD
1/2"
P611B
LEVER LAVATORY FAUCET-4" SPREAD
MOEN
8413SP
2
CHROME
VD
VD
1/2"
P702
WALK-IN COOLER/FREEZER - END DOOR
KOLPAK
CUSTOM
1
VD
GC
P704
SODA/ICE DISPENSER
CORNELIUS
IDC255
1
VD
VD
120/60
9.3
3/8"
3/4"
P707
ICE MAKER AT SODA MACHINE- AIR-COOLED
HOSHIZAKI AMERICA, INC.
KML-451MAH
1
VD
VD
115/60/1
10.3
1/2"
3/4"
P715
COOLER REFRIGERATION SYSTEM - REMOTE
COOLER
KOLPAK
POLAR PAK
1
VD
GC
208-230/60/
1
ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY
EQUIPMENT VENDOR
P716
COOLER REFRIGERATION SYSTEM - REMOTE
FREEZER
KOLPAK
POLAR PAK
1
VD
GC
208-230/60/
1
ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY
EQUIPMENT VENDOR
P800
GAS WATER HEATER
BRADFORD WHITE OR EQUAL
EF-60T-199
1
GC
GC
120/1
P804
ICE MAKER CONNECTION HOSE
DORMONT MANUFACTURING
W37B2Q48
1
VD
GC
P805
LEVER TWIST WASTES
T&S BRASS
B-3950
2
VD
GC
P807
WATER HEATER STAND
NATIONAL HOT WATER
PK101
1
GC
GC
SS
1/2"
1-1/2"
3/4"
1/2"
120/1/60
1780
14.8
NEMA 5-1SP
1-1/2"
SEE ITEM #P603 FOR FAUCET. PROVIDE TEMPERING VALVE.
USE FREEZELESS WALL FAUCET MOUNTED AT 32" AFF
1 1/2"
FAUCET INCLUDED
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
1/4"
PROVIDE TEMPERING VALVE
8" WALL MOUNT FAUCET, ADD-ON FAUCET W/ 8" SWING NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY
VALVE, VACUUM BREAKER & 6" WALL BRACKET & LEVER HANDLES
1/2"
USE FOR NEW STORES
REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR
1.8
H
1"
1"
STANDARD AIR COOLED UNIT
REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANK TO BE PROVIDED.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
P211
C
Wells
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.5 PLUMBING SCHEDULE.DWG
MODEL #
SHEET TITLE
PLUMBING
SCHEDULE
JYOU
MANUFACTURER
SHEET NUMBER
A2.5
1/13/2010 3:27:21 PM
DESCRIPTION
PROJECT NUMBER: 16-059
ITEM #
MODEL
LAMP
FURN INSTALL
VOLTS
WATTS
B.O. FIXTURE
COMMENTS
L100
DECORATIVE PENDANT - 14"
CON-TEC
SCHOOL HOUSE FIXTURE
11
CM5601150 W/ 8' ASSEMBLY
PHILIPS 11A19/END/2700/DIM 6/1
VD
GC
120
23
7'-9" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L102
ANTIQUE GLOBE FIXTURE
CUSTOM BY PSW
DECORATIVE CHAIN HUNG FIXTURE WITH VINTAGE COLORED TEXTURE GLASS SHADE
5
CUSTOM
PHILIPS EL/MDT2 13W
VD
GC
120
14
7'-9" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L104
WALL SCONCE - TOILET ROOM
REJUVENATION
SELMA WHITE PORCELEIN
2
A4631 / B2002 SHADE
PHILIPS EL/MDT 23W
VD
GC
120
23
CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF
L107
DECORATIVE PENDANT - 12"
REJUVENATION
BALDWIN - SINGLE CHAIN PENDANT OIL RUBBED BRONZE W/ 12" OPAL SHADE
4
A3167 / B5937 12" OPAL STEPPED SHADE
23W GU24 LAMP
VD
GC
120
23
7'-9" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L109
CYLINDER PENDANT
CON-TECH
6" CYLINDER PENDANT W/ 24" STEM KIT AND MONOPOINT
3
CF6-42P-C-B / CSK24-B / LA18-B
PHILIPS PL-T 42W/835/4P/ALTO
VD
GC
13'-0" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L200
CEILING MOUNTED FIXTURE
THOMAS LIGHTING
2-LIGHT CEILING MTD, PAINTED BRONZE, 13 1/4"
1
PL869263L
2 (13W) CFQ13/G24q/827 (4 PIN)
VD
GC
120
26
CEILING MOUNTED
L202
CEILING MOUNTED TOILET RM FIXTURE
REJUVENATION
FRANCIS BLACK PORCELEIN W/ BLACK STRIPED SHADE
2
A7685 / B1489 BLACK STRIPED SHADE
23W GU24 LAMP
VD
GC
120
23
N/A
L203
SURFACE MOUNT COOLER STRIP LIGHT
METALUX VAPORITE
1 X4 STRIP LIGHT (2) LAMP
1
VT-232-120-EB81
GE F28T8/SP35/UMX/ECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS
VD/GC
GC
120
L207
LED TRACK HEAD (MENU)
CON-TEC
PAR30 ROUND BACK CYLINDER TRACK HEAD
8
CTL230-B
SOLAIS LR30LN/25/30K/18W/1000/BK
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L208
LED TRACK HEAD (WALL FLOOD)
CON-TEC
PAR30 ROUND BACK CYLINDER TRACK HEAD
23
CTL230-B
SOLAIS LR30LN/40/30K/18W/1000/BK
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L210
LINEAR TRACK FIXTURE 48"
CON-TEC
LINEAR SLIM STYLE WALLWASH
3
CTL14154/HO-B
PHILIPS F54T5/835/HO/ALTO
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 13'-6" AFF
SEE DETAIL 12/A5.2
L302
RECESSED 2 X 4
COOPER
METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE
5
METALUX 2GR8-332A-UNV-EB81-U, 2X4 RECESSED
(3) PHILIPS LED T8 LAMPS; PRODUCT NO: 45359-7; ORDERING CODE: 12T8/48-3500 IF 10/1
VD
GC
L305
RECESSED 2 X 2
COOPER
METALUX, 2X2, 2 LAMP FLUORESCENT FIXTURE
1
2GC8-317A-UNV-EB81-U
(3) F17T8/SP35/ ITEM #45743
VD
GC
L310
6" RECESSED DOWNLIGHT (LED)
CON-TEC
6" INCADESCENT HOUSING AND TRIM
2
RL38 + CTR1902-WHT
SOLAIS LR38/25/30K/1025BK
VD
GC
L311
6" RECESSED DOWNLIGHT W/ WALLWASH (LED)
CON-TEC
6" INCADESCENT HOUSING AND WALLWASH TRIM
1
RL38 + CTR3807-WHT
LR38/25/30K/1025BK
VD
GC
L500
EMERGENCY LIGHT
TECHNICAL CONSUMER PRODUCTS
EMERGENCY LIGHT TCP 20760 Emergency
7
20760
EMERGENCY HALOGEN LIGHTS
VD
GC
L502
EMERGENCY EXIT SIGN W/ LIGHTS
TECHNICAL CONSUMER PRODUCTS
COMBO EMERGENCY EXIT SIGN W/ (2) HEADS
4
TCP 20723
VD
GC
L601
WALL MOUNTED SPEAKER
SOUNDTUBE
WALL MOUNT SPEAKER
2
SM400I
VD
VD
GC TO INSTALL BACKER BOX FOR SPEAKERS
L602
CEILING MOUNTED SPEAKER
LOWELL
8" DUAL CONE SPEAKER ASSEMBLY
3
R SERIES
VD
VD
GC TO INSTALL BACKER BOX FOR SPEAKERS
L610
72" EXTENSION ROD
REVOLUTION LIGHTING
72" IRON DOWN ROD - DR72VB
2
DR72VB
VD
GC
FOR USE WITH L400 CEILING FAN.
L611
LAMP CHANGER KIT
MR. LONGARM INC.
LAMP CHANGER KIT
1
B8601 3030
VD
GC
L613
3' X 5' EXHAUST HOOD
JD HIGGINS
SS HOOD W/ 18" ENCLOSURE PANEL
2
3624
VD
GC
L614
4'-0" BLACK TRACK
CON-TECH
4'-0" BLACK TRACK FOR LED TRACK HEADS
2
LT-4-B
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L615
6'-0" BLACK TRACK
CON-TECH
6'-0" BLACK TRACK FOR LED TRACK HEADS
12
LT-6-B
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L617
TRACK END FEED
CON-TECH
END FEED (ONE NEEDED FOR EACH TRACK)
9
LA-10-B
VD
GC
L618
TRACK CONNECTOR
CON-TECH
CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER
4
LA-2-B
VD
GC
L619
TRACK CORNER CONNECTOR
CON-TECH
CONNECTOR TO FIT TRACKS AT A 90 ANGLE
1
LA-12-B
VD
GC
L620
CURRENT LIMITING DEVICE
CON-TECH
CURRENT LIMITING POER FEED
5
LA-23-RN
VD
GC
120
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
FIXTURE BY VENDOR, LAMPS BY GC
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
6
WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERING
DRAWINGS
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.6 LIGHTING SCHEDULE.DWG
Count
SHEET TITLE
LIGHTING
SCHEDULE
JYOU
DESCRIPTION
SHEET NUMBER
A2.6
3/17/2010 5:39:48 PM
MANUFACTURER
PROJECT NUMBER: 16-059
TYPE
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ITEM #
LIGHTING SCHEDULE
ITEM #
DESCRIPTION
MANUFACTURER
MODEL #
SPECIFICATION
FURN
FINISH
INSTALL
A100
SHROUD SUPPORT - END, 18" H
CR LAURENCE (RETAIL)
SBPP08EBS
CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END
PARTITION POST
A101
SHROUD SUPPORT - MIDDLE, 18" H
CR LAURENCE (RETAIL)
SBPP08CBS
CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END
PARTITION POST
STAINLESS STEEL
VD
GC
A102
SHROUD SUPPORT - ANGLE (90), 18"
H
CR LAURENCE (RETAIL)
SBPP08LBS
CRL BRUSHED STAINLESS 18" x 1" SBPP08 SLIMLINE SERIES ROUND END
PARTITION POST
STAINLESS STEEL
VD
GC
A103
CHALK BOARD PANEL
RETAIL FIXTURE
STAINLESS STEEL
VD
GC
A104
2" STAINLESS STEEL SUPPORT LEG
RETAIL FIXTURE
WOOD SUBSTRATE WITH CHALKBOARD PAINT
VD
GC
A105
WALL CLEAT (COUNTER TOP
SUPPORT)
RETAIL FIXTURE
STAINLESS STEEL
VD
GC
A106
WOOD CHIP CUBBIE BASKET
RETAIL FIXTURE
WOOD
VD
GC
A107
POS SHROUDS
RETAIL FIXTURE
SOLID SURFACE
VD
GC
STAINLESS STEEL
VD
GC
COMMENTS
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
C116
SODA/ICE MACHINE SHROUD
RETAIL FIXTURE
PBSFC
68" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER
#RC60
C117
SODA/ICE MACHINE SHROUD (TX
ONLY)
RETAIL FIXTURE
PBSFC-TX
78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER
#RC60
STAIN: ST03; METAL PANEL: DAKOTA BLACK
VD
GC
STAIN: ST03; METAL PANEL: DAKOTA BLACK
VD
GC
TO BE USED AT TEXAS STORES ONLY
C119
DT ASSEMBLY COUNTER
RETAIL FIXTURE
CUSTOM
SOLID SURFACE COUNTER TOP (CN03)
VD
GC
C120
DT SODA COUNTER
RETAIL FIXTURE
CUSTOM
SOLID SURFACE COUNTER TOP (CN03)
VD
GC
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
DRIVE-THU LOCATIONS ONLY
DRIVE-THU LOCATIONS ONLY
C122
MANAGER'S DESK
RETAIL FIXTURE
PBMDSK
ALMONDINE MELAMINE
VD
GC
ESPRESSO FINISH
GC
GC
RESTROOM WALL CABINET
HOME DEPOT (OR EQUAL)
TREW2428
FOREMOST HAVEN WALL CABINET WITH 2 DOORS, 2 ADJ. SHELVES &
POLISHED CHROME KNOBS
MAY SUBSTITUTE FOR EQUAL SPECIFICATION. GC TO PROVIDE KEY AND LOCK.
STEEL FRAME - 2X2 18GA. SQUARE TUBING, WELDED CONSTRUCTION,
SMOOTH GRIND ALL EXPOSED WELDS; LEGS - 1/4X2O STAINLESS STEEL
LEGS W/ LEVELERS; SIDE PANELS - 3/4" BALTIC BIRCH/MELAMINE ATTACHED
TO STEEL FRAME; COUNTER: CORIAN OVER PLYWOOD
STEEL FRAME: BLACK POWDER COAT;
COUNTER: CORIAN -CN01; DOORS: ST03; SIDE
PANELS: ST-03; INTERIOR: ALMOND MELAMINE
VD
GC
C131
LARGE SODA CABINET (P-LAM)
RETAIL FIXTURE
C132
SODA/ICE MACHINE SHROUD (P-LAM)
RETAIL FIXTURE
PBSFC
68" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER
#RC60
STAIN: ST03; METAL PANEL: DAKOTA BLACK
VD
GC
C133
SODA/ICE MACHINE SHROUD (TX
ONLY) (P-LAM)
RETAIL FIXTURE
PBSFC-TX
78" HIGH - 3/4" PLYWOOD WITH METAL SCREENING PANEL - OUTWATER
#RC60
STAIN: ST03; METAL PANEL: DAKOTA BLACK
VD
GC
C134
TRASH - LARGE (PLAM)
RETAIL FIXTURE
PBLT
PLASTIC LAMINATE VERSION, CN-01 TOP
VD
GC
C135
TRASH - SMALL (PLAM)
RETAIL FIXTURE
PBST
PLASTIC LAMINATE VERSION, CN-01 TOP
VD
GC
C136
TRASH- SLIM JIM (PLAM)
RETAIL FIXTURE
PLASTIC LAMINATE VERSION, CN-01 TOP
VD
GC
TO BE USED AT TEXAS STORES ONLY
PROJECT NUMBER: 16-059
C123
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
3/4" MELAMINE
ISSUE DATE
SM SODA CABINET (P-LAM)
RETAIL FIXTURE
VD
GC
C139
LARGE SODA CABINET W/ BIB RACK
BELOW (P-LAM)
RETAIL FIXTURE
VD
GC
C140
SM SODA CABINET W/ BIB RACK
BELOW (P-LAM)
RETAIL FIXTURE
VD
GC
C200
ADA COUNTER FRONT PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (35-3/4"" W - VERIFY WITH SHOP DRAWINGS)
STAIN: ST03
VD
GC
C201
ORDER COUNTER FRONT PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (41-3/4" W - VERIFY WITH SHOP DRAWINGS)
STAIN: ST03
VD
GC
STAIN: ST03
VD
GC
STAIN: ST03
VD
GC
C202
CHIP CUBBIE (7 BAYS WIDE, 3 HIGH)
RETAIL FIXTURE
CUSTOM
CABINET - 3/4" BIRCH PLYWOOD SIDES AND INNER BACK, 3/4" SQ SOLID
WOOD EDGING, MELAMINE BACK PANEL; COUNTER - 3/4" BIRCH PLYWOOD
OVER 3/4" PLYWOOD SUBSTRATE W/ 3/4" BIRCH DROP EDGE
C203
DRESS COUNTER FRONT PANEL
RETAIL FIXTURE
CUSTOM
WOOD PANEL (SIZE VARIES - VERIFY WITH SHOP DRAWINGS)
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.7 CASEWORK SCHEDULE.DWG
C138
C204
POS FRONT PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (94-3/4" W - VERIFY WITH SHOP DRAWINGS)
STAIN: VARIES
VD
GC
C205
POS SIDE PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (46" W - VERIFY WITH SHOP DRAWINGS)
STAIN: VARIES
VD
GC
C206
END WALL HIGH PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (36" W - VERIFY WITH SHOP DRAWINGS)
C207
POS HIGH PANEL FRONT - DRIVE
THRU
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (51-1/4" W - VERIFY WITH SHOP DRAWINGS)
STAIN: VARIES
VD
GC
C208
POS HIGH PANEL SIDE - DRIVE THRU
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (46" W - VERIFY WITH SHOP DRAWINGS)
STAIN: VARIES
VD
GC
C209
ORDER/LOAD FRONT PANEL
RETAIL FIXTURE
CUSTOM
CUSTOM WOOD PANEL (47 3/4"" W - VERIFY WITH SHOP DRAWINGS)
STAIN: VARIES
VD
GC
CASEWORK
SCHEDULE
JYOU
SHEET TITLE
A2.7
9/29/2009 10:05:16 AM
SHEET NUMBER
MANUFACTURER
MODEL #
SPECIFICATION
FURN
FINISH
INSTALL
C300
ADA COUNTER
RETAIL FIXTURE
CUSTOM
SOLID SURFACE COUNTER TOP
MACCHIATO- POLISHED FINISH
VD
GC
C301
ORDER COUNTER TOP CAP
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C302
NOT USED
C303
DRESS COUNTER TOP CAP
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
MACCHIATO- POLISHED FINISH
VD
GC
COMMENTS
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
POS COUNTER
RETAIL FIXTURE
CUSTOM
SOLID SURFACE COUNTER TOP
MACCHIATO- POLISHED FINISH
VD
GC
RETAIL FIXTURE
CUSTOM
SOLID SURFACE COUNTER TOP
MACCHIATO- POLISHED FINISH
VD
GC
C305
POS COUNTER TOP CAP (SIDE)
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C306
END WALL TOP CAP
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C307
POS DT HIGH WALL TOP CAP
(FRONT)
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C308
POS DT HIGH WALL TOP CAP (SIDE)
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C309
ORDER/LOAD TOP CAP
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP - 9"
MACCHIATO- POLISHED FINISH
VD
GC
C310
DT WINDOW TOP CAP
RETAIL FIXTURE
CUSTOM
SOLID SURFACE TOP CAP -CUSTOM SIZE
PBSDW
SIDES/BACK/BOTTOM - 3/4 BIRCH PLYWOOD; BACKSPLASH - 3/4" MAPLE
TRIM; FACE FRAME - 3/4" X 2" MAPLE TRIM; CORNER TRIM - 1X1 TRIM;
PULLS - ROUND FLUSH PULL
STAIN ALL: ST04; PULLS: DARK BRONZE
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" 1/4"
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 43 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”)
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 43 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”)
V201
BACKLINE WALL CABINET - OPEN
RETAIL FIXTURE
RETAIL FIXTURE
V202
BACKLINE WALL CABINET - WOOD
RETAIL FIXTURE
V203
BACKLINE SHELVING
RETAIL FIXTURE
3/4" BIRCH PLYWOOD (3) W/ MAPLE D.E.
ST01
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL
V204
BACKLINE WALL CABINET - OPEN 40"
RETAIL FIXTURE
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" 1/4"
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 28 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”)
V205
BACKLINE WALL CABINET - WOOD 40"
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 28 1/4" (VISIBLE AREA 13-7/8” x 27-3/4”)
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" 1/4"
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 18-1/4” (VISIBLE AREA 13-7/8” x 17-3/4”)
PBUNG
SIDES/TOP/BOTTOM - 3/4" PLYWOOD; BACK - 3/8" BEADBOARD; FACE
FRAME - 3/4" X 2" MAPLE; SHELVES - (3) 3/4" PLYWOOD W/ MAPLE DROPPED
EDGE; DOORS - 3/4" X 2-1/4" POPLAR W/ WOOD PANEL INSERTS
SIDES/TOP/BOTTOM: ST11; BACK/SHELVES:
ST02
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL; CABINETPANEL SIZE 14-3/8” x 18-1/4” (VISIBLE AREA 13-7/8” x 17-3/4”)
RETAIL FIXTURE
V206
BACKLINE WALL CABINET - OPEN 30"
V207
BACKLINE WALL CABINET - WOOD 30"
RETAIL FIXTURE
V208
MENU HOLDER
RETAIL FIXTURE
VD
GC
LOCATE AS PER PLAN OR PSW DIRECTION
V209
TRAY HOLDER
RETAIL FIXTURE
VD
GC
ATTACH TO SIDE OF TRASH CABINETS
V210
BACKLINE WALL CABINET (PLAM)
RETAIL FIXTURE
PBUNG
PLASTIC LAMINATE VERSION
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL
V211
ICE CREAM WALL CABINET (PLAM)
RETAIL FIXTURE
PBSDW
PLASTIC LAMINATE VERSION
VD
GC
PROVIDE 3/4" FRT PLYWOOD BACKING IN WALL
W300
DECORATIVE DOOR CASING
RETAIL FIXTURE
POPLAR
STAINED BY RETAIL FIXTURE: ST-03
VD
GC
AT ALL DOORS UNLESS NOTED OTHERWISE
W301
CORNER TRIM
RETAIL FIXTURE
1" X 1" SOLID POPLAR CORNER TRIM (8' AT CEDAR, 4' AT BEADBOARD)
VARIES: GC TO STAIN ST-06 AT CEDAR / GC TO
PAINT: PT-04 AT BEAD BOARD
VD
GC
W302
TOP CAP
RETAIL FIXTURE
1" X 3" SOLID POPLAR TOP CAP
STAINED BY RETAIL FIXTURE: ST-01
VD
GC
INSTALL WITH POPLAR QUARTER ROUND
W303
CEDAR PLANKS - INTERIOR
RETAIL FIXTURE
1" X 6" TONGUE AND GROOVE CEDAR PLANKS
GC TO STAIN: ST-06
VD
GC
6" W PLANKS. INSTALL 1X3 WOOD CAP WITH QUARTER ROUND TRIM PIECE AT TOP, SMOOTH SIDE TO FACE OUT
W304
BEADBOARD PANELING
RETAIL FIXTURE
GEORGIA PACIFIC SANDED 1 1/2" O.C. BEAD PATTERN
STAINED BY RETAIL FIXTURE: ST-10
VD
GC
4' X 8' X 11/32" PANELS
W305
CHAIR RAIL
RETAIL FIXTURE
POPLAR
GC TO PAINT: PT-04
VD
GC
AT TOP OF BEAD BOARD
W306
QUARTER ROUND TRIM
RETAIL FIXTURE
POPLAR (AT CEDAR ONLY)
GC TO STAIN ST-06
VD
GC
AT ALL WOOD BASE AND SERVICE LINE
W309
WOOD APRON/ WALLTRIM/ DOOR
JAMB
RETAIL FIXTURE
1" X 6" POPLAR
STAINED BY RETAIL FIXTURES: VARIES (SOFFIT
TRIM: ST-04 / WALL TRIM ST-03)
VD
GC
AT ALL WINDOWS AS NOTED IN ELEVATIONS
W310
WOOD SILL
RETAIL FIXTURE
POPLAR
STAINED BY RETAIL FIXTURES: ST-03
VD
GC
AT ALL WINDOWS AS NOTED IN ELEVATIONS
W312
STANDING TRIM - STAINED
RETAIL FIXTURE
1" X 2" POPLAR TRIM
STAINED BY RETAIL FIXTURES; REFER TO
INTERIOR ELEVATIONS FOR MORE INFORMATION
VD
GC
REFER TO ELEVATIONS
W312A
STANDING TRIM - PAINTED
RETAIL FIXTURE
1" X 2" POPLAR TRIM
PAINTED BY GC; REFER TO INTERIOR
ELEVATIONS FOR MORE INFORMATION
VD
GC
REFER TO ELEVATIONS
VD
GC
AT TOP OF DOOR HEADS AS NOTED IN ELEVATIONS
VD
GC
RETAIL FIXTURE
W313
TRIM CAP
RETAIL FIXTURE
2" X 2" SOLID POPLAR
STAINED BY RETAIL FIXTURES: VARIES (SOFFIT
TRIM: ST-04 / WALL TRIM ST-03)
W314
PLINTH BLOCK AT COOLER TRIM
RETAIL FIXTURE
1-3/4" X 7-3/4" X 10" POPLAR PLINTH BLOCK
STAINED BY RETAIL FIXTURES: ST-03
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
POS COUNTER
ICE CREAM WALL CABINET
S t .,
ILLINOIS DESIGN FIRM # 184.006688
C304A
V200
H
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
C304
C
Wells
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.8 CASEWORK SCHEDULE (CONT.).DWG
DESCRIPTION
PROJECT NUMBER: 16-059
ITEM #
CEDAR TOP CAP
GC
2" X 8" CEDAR TOP CAP
GC TO STAIN: ST-06
GC
GC
AT TOP OF PARTIAL HEIGHT WALL AND SILL AT COOLER
W316
ROSETTE BLOCK (AT COOLER TRIM)
RETAIL FIXTURE
1" X 7-3/4" X 7-3/4" TH. BULL'S EYE BLOCK WITH ROSETTE CARVING
STAINED BY RETAIL FIXTURES: ST-03
VD
GC
AT COOLER TRIM
W317
PLYWOOD PANELS
GEORGIA PACIFIC
GRADE "B" SMOOTH FINISH
GC TO STAIN: ST-06
GC
GC
4' X 8' LUAN PLYWOOD PANELS, SMOOTH ON ONE SIDE. GLUE AND INSTALL TRIM AND NAILS
W318
FLAT DOOR CASING
RETAIL FIXTURE
1" X 3 1/2" POPLAR TRIM WITH MITERED CORNER
STAINED BY RETAIL FIXTURES: ST-03
VD
GC
DOOR TRIM IN BACK OF HOUSE AS NOTED IN ELEVATIONS
CASEWORK
SCHEDULE
SHEET NUMBER
A2.8
9/29/2009 10:05:16 AM
W315
JYOU
SHEET TITLE
SPECIFICATION
FINISH
FURN
INSTALL
COMMENTS
W319
COOLER TRIM BACK BAND
RETAIL FIXTURE
POPLAR
STAINED BY RETAIL FIXTURES: ST-03
VD
GC
INSTALL AROUND COOLER OPENING AS NOTED ON ELEVATIONS
W320
COOLER APRON PACKAGE
PSW - HUB
WOOD FRAMED CUSTOM MOSAIC TILE PANEL
STAINED BY PSW-HUB
PSW-HUB
GC
INSTALL AT APRON OF COOLER AS NOTED ON ELEVATIONS. COORDINATE DIMENSIONS WITH PSW REP
W321
POLE WRAP
TAMBOUR POLE WRAP
8' HIGH - VARIOUS LENGTHS AVAILABLE (12", 16" OR 48")
REFER TO ELEVATIONS
GC
GC
AVAILABLE AT HOME DEPOT AND LOWES
RETAIL FIXTURE
COLUMN - CLEAR PINE SMOOTH COLUMN AND ENDS; BACK PANEL - 3/8"
BEADBOARD BACK; TOP/BOTTOM/SIDES/SHELVES - 1-1/2" CONSTRUCTION
GRADE LUMBER, PANEL INSERTS - 3/4" PLYWOOD
STAINED BY RETAIL FIXTURES: ST-01
VD
GC
PROVIDE ELECTRICAL AS REQUIRED
W322
BOOKCASE
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
6" CEDAR PLANKS - EXTERIOR
GC
6" ROUGH SEWN CEDAR PLANKS
GC TO STAIN: ST-08
GC
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
GC
W324
4" CEDAR PLANKS - EXTERIOR
GC
4" ROUGH SEWN CEDAR PLANKS
GC TO STAIN: ST-08
GC
GC
W325
4" BEVEL BASE
RETAIL FIXTURE
1"X4" POPLAR WITH BEVEL EDGE
STAINED BY RETAIL FIXTURES: ST-03
GC
GC
AT ALL WOOD BASE
W326
4" CHAIR RAIL
RETAIL FIXTURE
1"X4" POPLAR
STAINED BY RETAIL FIXTURES: ST-03
GC
GC
AT ALL WOOD CHAIR RAIL
ADL2
4 X 4 CEDAR POSTS
GC
4" X 4" X 9' H CEDAR POSTS
STAIN: ST-06
GC
GC
BACK POSTS AT PLATFORM
ADL3
6 X 6 DECORATIVE POSTS
RETAIL FIXTURE
6" X 6" X 9' H DECORATIVE POST
PAINT PT-11 OR STAIN:ST-10
VD
GC
FRONT POST AT PLATFORM
ADL5
PICTURE FRAME
RETAIL FIXTURE
1" X 2" FLAT WOOD TRIM
PAINTED BY GC; REFER TO INTERIOR
ELEVATIONS FOR MORE INFORMATION
VD
GC
REFER TO ELEVATIONS
ADL6
DECORATIVE WOOD PANELS
GC
18" W WOOD BI-FOLD DOOR
PAINT: PT-01
GC
GC
REFER TO ELEVATIONS
ADL7
PLATFORM ABOVE BOOTH
GC
GC
GC
REFER TO ELEVATIONS
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
W323
C
Wells
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A2.9 CASEWORK SCHEDULE (CONT.).DWG
MODEL #
SHEET TITLE
CASEWORK
SCHEDULE
JYOU
MANUFACTURER
SHEET NUMBER
A2.9
9/29/2009 10:05:16 AM
DESCRIPTION
PROJECT NUMBER: 16-059
ITEM #
KEY NOTES
S223
S222A 10
S209
4
2
3
8
8
6
6
9
7
30'-2" VIF PSW SPACE
01
EXISTING SOUTH ELEVATION
SCALE: 3/16" = 1'-0"
EXISTING NORTH ELEVATION
02
SCALE: 3/16" = 1'-0"
2
EXISTING STOREFRONT
3
EXISTING AWNING
4
EXISTING FRONT ENTRY
5
EXISTING SIDE ENTRY
6
EXISTING SCONCES
7
BRICK
8
EIFS
9
REAR DOOR
10
VINYL LOGO & STORE HOURS ON DOOR
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PROJECT NUMBER: 16-059
7
1
INTERNALLY ILLUMINATED WALL SIGN
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
3
1
1
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
1
8
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A3.0 EXTERIOR ELEVATIONS.DWG
7
6
3
5
3
2
6
3
2
EXTERIOR
ELEVATIONS
7
JYOU
SHEET TITLE
03
EXISTING EAST ELEVATION
SCALE: 3/16" = 1'-0"
A3.0
12/21/2009 4:27:39 PM
SHEET NUMBER
KEY NOTES
PT-37
PT-37
31
PT-19
W312
5
SWINGING SERVICE DOOR.
6
DOOR TRIM, REFER TO DETAIL 01/A2.0.
7
VINYL MARKETING MESSAGE ON WINDOW.
8
PROVIDE BLOCKING IN WALL
9
COOLER OPENING WITH TRIM SURROUND.
REFER TO DETAIL 04/A5.0 .
10
1x2 WOOD TRIM.
11
CEDAR TONGUE AND GROOVE PANELS.
12
BEADBOARD PANELS.
13
CUSTOM WALLPAPER.
14
SODA CABINET. REFER TO MILLWORK AND
PLUMBING SHEETS.
4'-4"
T.O. WALL
15
4'-0"
T.O. DOOR
16
BACK BOARD CABINET-LOWEST SHELF TO
BE 6" D.
SERVICE LINE CABINETRY. REFER TO CASEWORK
SHEET FOR INFORMATION.
26
16'-0"
B.O. DECK L.P.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
13'-0"
T.O. TRIM
PT-47
WR01
28
W305
PT-04
4'-0"
T.O. TRIM
12
W304
0'-0"
B.O. FIN. FLR
WB-04
2
01
1
18
4
S222A
42
S209
43
S223
7
2
SCALE: 3/8"=1'-0"
WR01
8
S221
45
8
S201
02
ENTRY FROM SERVICE TO DINING
PT-19
SCALE: 3/8"=1'-0"
PT-19
8
2'-2"
35
27
SMALL TRASH CAN.
18
LARGE TRASH CAN.
19
BOOTH SEATING.
20
BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL
SHEETS FOR POWER REQUIREMENTS.
21
DISPLAY PLATFORM ABOVE.
22
PARTIAL HEIGHT WALL AT QUEUING LINE.
23
END WALL AT SERVICE LINE. GC TO PROVIDE 5 8"
DUROCK AT MILLWORK WALL TO RECEIVE TILE.
24
4X4 CEDAR POSTS AT BACK OF PLATFORM
25
CUSTOM POSTS AT FRONT OF PLATFORM,
COORD WITH PSW REP.
26
STANDING TRIM
27
1X6 END TRIM
28
CHAIR RAIL.
29
CORNER MOULDING, TYPICAL AT ALL EXPOSED
CORNERS.
30
SUBMARINE DUCT WITH ROTATING PROPELLER,
REFER TO DETAIL 13/A5.2.
31
HVAC DUCT, PAINTED PT-19. REFER TO
MECHANICAL SHEETS FOR INFORMATION.
32
MECHANICAL HOOD AT OVENS.
33
HANGING MARKETING SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
"YA GOTTA GET IT HOT" SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
1
ELEVATION AT ENTRY
44
17
S216A
8
34
W309
YA
GOTTA
GET IT
13
PT-02
28
PT-04
34
WC-01
W305
W305
W303
11
WT-02
W319
03
ELEVATION AT SERVICE/DINING
35
SOUP/SHAKE MENU BOARD.
36
SANDWICH MENU BOARD.
37
DESSERT MENU BOARD.
38
DECORATIVE TILE PANEL AT COOLER APRON
39
PAPER TOWEL DISPENSER
40
SOAP DISPENSER
41
WALL MOUTED SERVICE SINK
42
VINYL STORE LOGO AND HOURS
43
11X17 CHALKBOARD SIGN
44
OUR SANDWICHES SIGN
45
ORDER HERE FINGER
46
SOLID SURFACE COUNTER TOP AND TOP CAP.
OPEN
9
SCALE: 3/8"=1'-0"
04
ENTRY FROM DINING/SERVICE
SCALE: 3/8"=1'-0"
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.0 INTERIOR ELEVATIONS.DWG
4
INTERIOR ILLUMINATED WINDOW SIGNAGE.
PROVIDE POWER. REFER TO ELECTRICAL
DRAWINGS.
ENTRY DOORS.
3
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
EXISTING COLUMN.
SHEET NUMBER
A4.0
12/21/2009 4:28:08 PM
2
PROJECT NUMBER: 16-059
EXISTING STOREFRONT SYSTEM TO REMAIN.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
1
KEY NOTES
PT-19
WR01
PT-37
PT-19
WR01
INTERIOR ILLUMINATED WINDOW SIGNAGE.
PROVIDE POWER. REFER TO ELECTRICAL
DRAWINGS.
PT-37
4
ENTRY DOORS.
5
SWINGING SERVICE DOOR.
6
DOOR TRIM, REFER TO DETAIL 01/A2.0.
7
VINYL MARKETING MESSAGE ON WINDOW.
8
PROVIDE BLOCKING IN WALL
9
COOLER OPENING WITH TRIM SURROUND.
REFER TO DETAIL 04/A5.0 .
10
1x2 WOOD TRIM.
11
CEDAR TONGUE AND GROOVE PANELS.
12
BEADBOARD PANELS.
13
CUSTOM WALLPAPER.
PT-04
14
SODA CABINET. REFER TO MILLWORK AND
PLUMBING SHEETS.
4'-0"
T.O. TRIM
15
BACK BOARD CABINET-LOWEST SHELF TO
BE 6" D.
SERVICE LINE CABINETRY. REFER TO CASEWORK
SHEET FOR INFORMATION.
16'-0"
B.O. DECK L.P.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
13'-0"
T.O. TRIM
3'-0"
16
0'-0"
B.O. FIN. FLR
1
01
2
1
1
2
1
ELEVATION AT DINING
S222A
42
4
26
PT-19
W312
PT-19
WC-02
13
W326
16'-0"
B.O. DECK L.P.
13'-0"
T.O. TRIM
7'-0"
T.O. TRIM
W303
0'-0"
B.O. FIN. FLR
2
02
ELEVATION AT DINING
18
LARGE TRASH CAN.
19
BOOTH SEATING.
20
BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL
SHEETS FOR POWER REQUIREMENTS.
21
DISPLAY PLATFORM ABOVE.
22
PARTIAL HEIGHT WALL AT QUEUING LINE.
23
END WALL AT SERVICE LINE. GC TO PROVIDE 5 8"
DUROCK AT MILLWORK WALL TO RECEIVE TILE.
24
4X4 CEDAR POSTS AT BACK OF PLATFORM
25
CUSTOM POSTS AT FRONT OF PLATFORM,
COORD WITH PSW REP.
26
STANDING TRIM
27
1X6 END TRIM
28
CHAIR RAIL.
29
CORNER MOULDING, TYPICAL AT ALL EXPOSED
CORNERS.
30
SUBMARINE DUCT WITH ROTATING PROPELLER,
REFER TO DETAIL 13/A5.2.
31
HVAC DUCT, PAINTED PT-19. REFER TO
MECHANICAL SHEETS FOR INFORMATION.
32
MECHANICAL HOOD AT OVENS.
33
HANGING MARKETING SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
"YA GOTTA GET IT HOT" SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
34
W326
11
SMALL TRASH CAN.
2
SCALE: 3/8"=1'-0"
PT-37
17
35
SOUP/SHAKE MENU BOARD.
36
SANDWICH MENU BOARD.
37
DESSERT MENU BOARD.
38
DECORATIVE TILE PANEL AT COOLER APRON
39
PAPER TOWEL DISPENSER
40
SOAP DISPENSER
41
WALL MOUTED SERVICE SINK
42
VINYL STORE LOGO AND HOURS
43
11X17 CHALKBOARD SIGN
44
OUR SANDWICHES SIGN
45
ORDER HERE FINGER
46
SOLID SURFACE COUNTER TOP AND TOP CAP.
1
SCALE: 3/8"=1'-0"
R
4 0 4 S.
C
H
Wells
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.1 INTERIOR ELEVATIONS.DWG
PT-19
26
3
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
W312
PT-37
EXISTING COLUMN.
SHEET NUMBER
A4.1
12/21/2009 4:28:38 PM
WR01
PT-09
2
PROJECT NUMBER: 16-059
PT-19
PT-09
EXISTING STOREFRONT SYSTEM TO REMAIN.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
PT-09
1
KEY NOTES
3
INTERIOR ILLUMINATED WINDOW SIGNAGE.
PROVIDE POWER. REFER TO ELECTRICAL
DRAWINGS.
PT-19
4
ENTRY DOORS.
5
SWINGING SERVICE DOOR.
6
DOOR TRIM, REFER TO DETAIL 01/A2.0.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
26
PT-19
12
A5.0
VINYL MARKETING MESSAGE ON WINDOW.
8
PROVIDE BLOCKING IN WALL
9
COOLER OPENING WITH TRIM SURROUND.
REFER TO DETAIL 04/A5.0 .
10
1x2 WOOD TRIM.
11
CEDAR TONGUE AND GROOVE PANELS.
12
BEADBOARD PANELS.
13
CUSTOM WALLPAPER.
14
SODA CABINET. REFER TO MILLWORK AND
PLUMBING SHEETS.
15
BACK BOARD CABINET-LOWEST SHELF TO
BE 6" D.
SERVICE LINE CABINETRY. REFER TO CASEWORK
SHEET FOR INFORMATION.
16
WB-04
01 ELEVATION AT DINING
02 ELEVATION AT PARTIAL HEIGHT WALL
SCALE: 3/8"=1'-0"
PT-16
PT-19
WR01
SCALE: 3/8"=1'-0"
PT-37
WC-01
13
PT-19
WR01
PT-19
S218
PT-03
16'-0"
B.O. DECK L.P.
26
PT-19
W312
13'-0"
T.O. TRIM
10'-0"
B.O. SOFFIT
PT-04
W305
4'-0"
T.O. TRIM
12
SMALL TRASH CAN.
18
LARGE TRASH CAN.
19
BOOTH SEATING.
20
BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL
SHEETS FOR POWER REQUIREMENTS.
21
DISPLAY PLATFORM ABOVE.
22
PARTIAL HEIGHT WALL AT QUEUING LINE.
23
END WALL AT SERVICE LINE. GC TO PROVIDE 5 8"
DUROCK AT MILLWORK WALL TO RECEIVE TILE.
24
4X4 CEDAR POSTS AT BACK OF PLATFORM
25
CUSTOM POSTS AT FRONT OF PLATFORM,
COORD WITH PSW REP.
26
STANDING TRIM
27
1X6 END TRIM
28
CHAIR RAIL.
29
CORNER MOULDING, TYPICAL AT ALL EXPOSED
CORNERS.
30
SUBMARINE DUCT WITH ROTATING PROPELLER,
REFER TO DETAIL 13/A5.2.
31
HVAC DUCT, PAINTED PT-19. REFER TO
MECHANICAL SHEETS FOR INFORMATION.
32
MECHANICAL HOOD AT OVENS.
33
HANGING MARKETING SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
"YA GOTTA GET IT HOT" SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
34
7'-0"
28
7'-5 1/2" A.F.F.
PT-37
17
35
SOUP/SHAKE MENU BOARD.
36
SANDWICH MENU BOARD.
37
DESSERT MENU BOARD.
38
DECORATIVE TILE PANEL AT COOLER APRON
39
PAPER TOWEL DISPENSER
40
SOAP DISPENSER
41
WALL MOUTED SERVICE SINK
42
VINYL STORE LOGO AND HOURS
43
11X17 CHALKBOARD SIGN
44
OUR SANDWICHES SIGN
45
ORDER HERE FINGER
46
SOLID SURFACE COUNTER TOP AND TOP CAP.
47
GLASS TILE ON FACE OF CHIP CUBBIE BASE.
TYPICAL OF (3) SIDES.
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
2
WB-04
03 ELEVATION AT SERVICE LINE
14
WB-06
SCALE: 3/8"=1'-0"
R
S
0334
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
W304
0'-0"
B.O. FIN. FLR
E
955
ILLINOIS DESIGN FIRM # 184.006688
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
W312
7
C
Wells
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.2 INTERIOR ELEVATIONS.DWG
EXISTING COLUMN.
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
WR01
2
SHEET NUMBER
A4.2
12/21/2009 4:29:06 PM
PT-27
EXISTING STOREFRONT SYSTEM TO REMAIN.
PROJECT NUMBER: 16-059
1
KEY NOTES
3
INTERIOR ILLUMINATED WINDOW SIGNAGE.
PROVIDE POWER. REFER TO ELECTRICAL
DRAWINGS.
4
ENTRY DOORS.
5
SWINGING SERVICE DOOR.
6
DOOR TRIM, REFER TO DETAIL 01/A2.0.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
7
VINYL MARKETING MESSAGE ON WINDOW.
8
PROVIDE BLOCKING IN WALL
9
COOLER OPENING WITH TRIM SURROUND.
REFER TO DETAIL 04/A5.0 .
10
1x2 WOOD TRIM.
11
CEDAR TONGUE AND GROOVE PANELS.
12
BEADBOARD PANELS.
13
CUSTOM WALLPAPER.
14
SODA CABINET. REFER TO MILLWORK AND
PLUMBING SHEETS.
15
BACK BOARD CABINET-LOWEST SHELF TO
BE 6" D.
SERVICE LINE CABINETRY. REFER TO CASEWORK
SHEET FOR INFORMATION.
16
W322
01 ELEVATION AT FRON SERICE LINE WALL - INTERIOR
SCALE: 3/8"=1'-0"
S204
02
20
ELEVATION AT HALF WALL
SCALE: 3/8"=1'-0"
8
17
SMALL TRASH CAN.
18
LARGE TRASH CAN.
19
BOOTH SEATING.
20
BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL
SHEETS FOR POWER REQUIREMENTS.
21
DISPLAY PLATFORM ABOVE.
22
PARTIAL HEIGHT WALL AT QUEUING LINE.
23
END WALL AT SERVICE LINE. GC TO PROVIDE 5 8"
DUROCK AT MILLWORK WALL TO RECEIVE TILE.
24
4X4 CEDAR POSTS AT BACK OF PLATFORM
25
CUSTOM POSTS AT FRONT OF PLATFORM,
COORD WITH PSW REP.
26
STANDING TRIM
27
1X6 END TRIM
28
CHAIR RAIL.
29
CORNER MOULDING, TYPICAL AT ALL EXPOSED
CORNERS.
30
SUBMARINE DUCT WITH ROTATING PROPELLER,
REFER TO DETAIL 13/A5.2.
31
HVAC DUCT, PAINTED PT-19. REFER TO
MECHANICAL SHEETS FOR INFORMATION.
32
MECHANICAL HOOD AT OVENS.
33
HANGING MARKETING SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
"YA GOTTA GET IT HOT" SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
34
4'-0"
3'-8"
6"
W322
03 ELEVATION AT SERVICE LINE BACK WALL
SCALE: 3/8"=1'-0"
20
WALL
04 ELEVATION AT HALF
SCALE: 3/8"=1'-0"
35
SOUP/SHAKE MENU BOARD.
36
SANDWICH MENU BOARD.
37
DESSERT MENU BOARD.
38
DECORATIVE TILE PANEL AT COOLER APRON
39
PAPER TOWEL DISPENSER
40
SOAP DISPENSER
41
WALL MOUTED SERVICE SINK
42
VINYL STORE LOGO AND HOURS
43
11X17 CHALKBOARD SIGN
44
OUR SANDWICHES SIGN
45
ORDER HERE FINGER
46
SOLID SURFACE COUNTER TOP AND TOP CAP.
47
GLASS TILE ON FACE OF CHIP CUBBIE BASE.
TYPICAL OF (3) SIDES.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
7'-0"
4 0 4 S.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.3 INTERIOR ELEVATIONS.DWG
EXISTING COLUMN.
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
2
SHEET NUMBER
A4.3
12/21/2009 4:29:41 PM
EXISTING STOREFRONT SYSTEM TO REMAIN.
PROJECT NUMBER: 16-059
1
KEY NOTES
31
PT-19
W312
WR01
26
PT-19
WR01
PT-19
PT-37
16'-0"
B.O. DECK L.P.
16'-0"
B.O. DECK L.P.
3
4
ENTRY DOORS.
5
SWINGING SERVICE DOOR.
6
DOOR TRIM, REFER TO DETAIL 01/A2.0.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
13'-0"
T.O. TRIM
13'-0"
T.O. TRIM
4'-0"
W312
EQ
26
PT-19
EQ
7'-0"
7'-0"
B.O.HEADER
7'-6"
02
A5.0
02
A5.0
4'-0"
T.O. WALL
OPEN
BEYOND
4'-0"
T.O. WALL
7
VINYL MARKETING MESSAGE ON WINDOW.
8
PROVIDE BLOCKING IN WALL
9
COOLER OPENING WITH TRIM SURROUND.
REFER TO DETAIL 04/A5.0 .
10
1x2 WOOD TRIM.
11
CEDAR TONGUE AND GROOVE PANELS.
12
BEADBOARD PANELS.
13
CUSTOM WALLPAPER.
14
SODA CABINET. REFER TO MILLWORK AND
PLUMBING SHEETS.
15
BACK BOARD CABINET-LOWEST SHELF TO
BE 6" D.
SERVICE LINE CABINETRY. REFER TO CASEWORK
SHEET FOR INFORMATION.
16
0'-0"
B.O. FIN. FLR
W312
01
S213
PT-04
0'-0"
B.O. FIN. FLR
WB-04
8
WB-04
ELEVATION AT DINING/DOOR TO PREP/TOILET VESTIBULE
PT-16
SCALE: 3/8"=1'-0"
PT-16
02
ELEVATION AT REAR EXIT
PT-16
PT-16
8'-6"
B.O. CEILING
7'-0"
B.O. HEADER
28
PT-04
7'-0"
B.O. HEADER
W305
W305
PT-04
4'-0"
T.O. TRIM
W304
W304
0'-0"
B.O. FIN. FLR.
W308
03 ELEVATION AT RESTROOM
SCALE: 3/8"=1'-0"
7'-0"
B.O. HEADER
4'-0"
T.O. WALL
0'-0"
B.O. FIN. FLR
0'-0"
B.O. FIN. FLR
W308
04 ELEVATION AT RESTROOM
SCALE: 3/8"=1'-0"
05 ELEV AT RR VESTIBULE
SCALE: 3/8"=1'-0"
SMALL TRASH CAN.
18
LARGE TRASH CAN.
19
BOOTH SEATING.
20
BOOKSHELF WITH LIGHT. REFER TO ELECTRICAL
SHEETS FOR POWER REQUIREMENTS.
21
DISPLAY PLATFORM ABOVE.
22
PARTIAL HEIGHT WALL AT QUEUING LINE.
23
END WALL AT SERVICE LINE. GC TO PROVIDE 5 8"
DUROCK AT MILLWORK WALL TO RECEIVE TILE.
24
4X4 CEDAR POSTS AT BACK OF PLATFORM
25
CUSTOM POSTS AT FRONT OF PLATFORM,
COORD WITH PSW REP.
26
STANDING TRIM
27
1X6 END TRIM
28
CHAIR RAIL.
29
CORNER MOULDING, TYPICAL AT ALL EXPOSED
CORNERS.
30
SUBMARINE DUCT WITH ROTATING PROPELLER,
REFER TO DETAIL 13/A5.2.
31
HVAC DUCT, PAINTED PT-19. REFER TO
MECHANICAL SHEETS FOR INFORMATION.
32
MECHANICAL HOOD AT OVENS.
33
HANGING MARKETING SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
"YA GOTTA GET IT HOT" SIGN. REFER TO
ELECTRICAL SHEETS FOR POWER
REQUIREMENTS.
34
12
0'-0"
B.O. FIN. FLR.
17
8'-6"
B.O. CEILING
28
4'-0"
T.O. TRIM
12
SCALE: 3/8"=1'-0"
06 ELEV AT RR VESTIBULE
SCALE: 3/8"=1'-0"
R
4 0 4 S.
35
SOUP/SHAKE MENU BOARD.
36
SANDWICH MENU BOARD.
37
DESSERT MENU BOARD.
38
DECORATIVE TILE PANEL AT COOLER APRON
39
PAPER TOWEL DISPENSER
40
SOAP DISPENSER
41
WALL MOUTED SERVICE SINK
42
VINYL STORE LOGO AND HOURS
43
11X17 CHALKBOARD SIGN
44
OUR SANDWICHES SIGN
45
ORDER HERE FINGER
46
SOLID SURFACE COUNTER TOP AND TOP CAP.
47
GLASS TILE ON FACE OF CHIP CUBBIE BASE.
TYPICAL OF (3) SIDES.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.4 INTERIOR ELEVATIONS.DWG
WR01
INTERIOR ILLUMINATED WINDOW SIGNAGE.
PROVIDE POWER. REFER TO ELECTRICAL
DRAWINGS.
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
13
EXISTING COLUMN.
SHEET NUMBER
A4.4
12/21/2009 4:30:21 PM
WC-03
PT-27
2
PROJECT NUMBER: 16-059
PT-19
PT-03
EXISTING STOREFRONT SYSTEM TO REMAIN.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
PT-27
1
KEY NOTES
5'-9" BLOCKING
10'-6"
B.O. CEILING
10'-6"
B.O. CEILING
6'-11"
BLOCKING
3
MANAGERS DESK. REFER TO DETAIL 12/A5.1
FOR ADDITIONAL INFO.
4
PROVIDE BLOCKING IN WALL
5
MOP BASIN. REFER TO PLUMBING DRAWINGS.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
0'-0"
B.O. FIN. FLR
3
ELEVATION AT PREP ROOM
13
SCALE: 3/8"=1'-0"
02
13
ELEVATION AT PREP ROOM
7
WALL MOUNTED HAND SINK. REFER TO
PLUMBING DRAWINGS.
8
3-COMP. SINK. REFER TO PLUMBING DRAWINGS.
9
SOAP DISPENSER
10
SHELVING ON CASTERS
11
PAPER TOWEL DISPENSER
12
WALK-IN COOLER/FREEZER
13
STAINLESS STEEL CORNER GUARD
14
BAG-N-BOX. REFER TO DETAIL 11/A5.0
SCALE: 3/8"=1'-0"
10'-6"
B.O. CEILING
WALK IN
COOLER
0'-0"
B.O. FIN. FLR
PREP TABLE. REFER TO PLUMBING DRAWINGS
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
2
04
A5.2
10'-6"
B.O. CEILING
6
15
NOT USED
16
LOCATION OF CHEMICAL DISPENSER.
17
6" DIA. PVC SLEEVE LOCATED IN GYP. BD. SOFFIT
FOR SODA LINES. REFER TO DETAIL 11/A5.0
18
WATER HEATER.
PROJECT NUMBER: 16-059
01
8
EMPLOYEE COAT HOOKS
6'-2"
4'-0"
5'-2"
4'-0"
3'-9"
0'-0"
B.O. FIN. FLR
WB-01
2
ILLINOIS DESIGN FIRM # 184.006688
6'-4"
7'-7"
6'-0" BLOCKING
3'-8"
BLOCKING
ELECTRICAL PANELS
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
4
1
0'-0"
B.O. FIN. FLR
ISSUE DATE
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A4.5 INTERIOR ELEVATIONS.DWG
SCALE: 3/8"=1'-0"
DATE
04-26-2016
05-23-2016
SHEET TITLE
INTERIOR
ELEVATIONS
JYOU
3'-0" FAUCET
0'-0"
B.O. FIN. FLR.
16
3'-0" FAUCET
6'-3" SHELF
SCALE: 3/8"=1'-0"
ELEVATION
AT
PREP
ROOM
04
6'-3" SHELF
ELEVATION
AT
PREP
ROOM
03
ISSUE
DD SET
95% SET
05 ELEV. AT UTILITY ROOM
SCALE: 3/8"=1'-0"
06 ELEV. AT UTILITY ROOM
SCALE: 3/8"=1'-0"
07 ELEV. AT UTILITY ROOM
SCALE: 3/8"=1'-0"
08 ELEV. AT UTILITY ROOM
SCALE: 3/8"=1'-0"
A4.5
12/21/2009 4:30:21 PM
SHEET NUMBER
5/8" GYP BD ON 3
5/8" METAL STUD
FRAMING
WOOD CAP W313
15
A5.0
COOLER APRON
PACKAGE
W320
TILE JAMB WITH
SEALANT AT SIDES,
NOT GROUT (TILE TO
MATCH TILE BEHIND
SERVICE LINE)
A
W300 W319
SCALE: 1 1/2" = 1'-0"
03
SCALE: 3" = 1'-0"
07
SECTION @ END CONDITON
SCALE: 1" = 1'-0"
08
SECTION @ LOW WALL
GYP BD / METAL STUD
WALL
SCALE: 1" = 1'-0"
09
CLOSURE DETAIL
SCALE: 3" = 1'-0"
WOOD ROSETTE
W316
10
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
10 1/2"
10 1/2"
2"
6 1/2"
WOOD APRON
W309
STAINLESS STEEL
CLOSURE STRIPS
ATTACHED TO COOLER
WALL ONLY FROM
VENDOR
E
300
1"
WOOD TRIM (2X2 CUT TO SIZE)
W313
COOLER HEAD
SCALE: 3" = 1'-0"
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
1 1/2" DIA. EYEBOLT
ON IRON STANCHION
COOLER
W302
PREFABRICATED COOLER
QUEUING
LINE
METAL CHAIN
CONT. SEALANT (BOTH SIDES TYP.)
7 3/4"
QUARTER ROUND TRIM
2 1/2" QUARRY TILE BASE
W306
QUARRY TILE FLOORING ON THINSET
GROUT OVER WATERPROOF
MEMBRANE
CEDAR TONGUE &
GROOVE PLANKS W303
SMOOTH FACE OUTGC TO
STAIN CEDAR ST-06
VARIES
7'-0"
TOP OF WOOD TRIM
7'-7"
CO2 TANK SECURED TO
RACK WITH CHAIN BY GC
W300 W319
GYP BD WALL
TILE JAMB
3/4" BASE PLATE W/ 3/8" X 3"
CONCRETE WEDGE FASTENERS
SILICONE BEAD AT
PERIMETER (CLEAR)
WALK-IN
COOLER
EXISTING CONCRETE SLAB
SHEET TITLE
NOTE: PAINT FASTENERS TO
MATCH BASE PLATE. DO NOT PAINT
UNFINISHED WROUGHT IRON
STANCHION
WOOD BASE
WB04
LEAVE 7 1/2" MIN. GAP
FOR BIB PUMP
DOOR CASING W/ BACK
BAND
1/4" MIN.
WROUGHT IRON STANCHIONS
BAG IN THE BOX RACKS
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.0 INTERIOR DETAILS.DWG
POPLAR TOP CAP
WATER LINE
WALL SHELF FOR
CARBONATOR
QUEUING
LINE
TILE JAMB
6" DIA. PVC
SLEEVE FOR
SODA LINES
ELECTRICAL OUTLET
CL @ 7'-7"
SILICONE BEAD AT
PERIMETER (CLEAR)
WALK-IN
COOLER
WOOD BASE WB04
NOTE: LEAVE
2" GAP AT
SIDE AND
BACK WALL
BLOCKING IN WALL
SILICONE BEAD AT
PERIMETER (CLEAR)
PREFAB COOLER WALLS
FROM VENDOR
T
Suite
NOTE: IF NOT SLAB ON GRADE,
COOLER WILL BE PROVIDED WITH
INTEGRAL FLOORING. NO QUARRY
TILE FLOOR OR BASE INSIDE COOLER
WHEN NOT SLAB ON GRADE
NOTE: ALL DISSIMILAR MATERIALS
TO HAVE FLEXIBLE GROUT
INTERIOR
DETAILS
JYOU
SCALE: 1/2" = 1'-0"
WOOD BASE WB04
3/4" SQ WELDED
BASE PLATE W/ 3/8"
X 3" CONCRETE
WEDGE FASTENERS
DOOR CASING
W300
1" CLEAR BETWEEN GYP
BD AND COOLER WALL
3 5/8" METAL STUD WITH 2" X 2"
STEEL PIPE W/ 3/4" SQ WELDED
BASE PLATE W/ 3/8" X 3"
CONCRETE WEDGE FASTENERS
(WALL TYPE 8)
3'-0"
6"
MILLWORK
SODA
CABINET
4'-0"
TO T.O. WOOD TRIM
WOOD CORNER TRIM W301
AT ALL (4) EDGES
GC TO PAINT PT-04
WOOD CAP W313
1 1/2"
1'-2"
4'-0"
TO T.O. WOOD TRIM
3/4" PLYWOOD PANELS W317
OVER METAL STUDS ON
OUTSIDE FACE - BOTH SIDES
GC TO STAIN ST-06.
3/4" PLYWOOD PANELS W317
ON OUTSIDE FACE - BOTH SIDES
GC TO STAIN ST-06
I
SCALE: 3/4" = 1'-0"
1" MIN.
6" DIA. PVC
CENTERED IN
CHASE
S t .,
SEALANT
2"
12" X 12" CEDAR TOP CAP,
SIMILAR TO W315
GC TO STAIN ST-06
5/8" GYP BD,
TYP.
06
COOLER OPENING - SECTION ELEVATION
CEDAR TOP CAP W315
GC TO STAIN ST-06
METAL STUDS
CHASE @ SODA CABINET
04
B.O. SILL
A.F.F.
HOLD
END COND. @ LOW WALL
COOLER APRON
PACKAGE W320
ALIGN WITH B.O.
CEDAR CAP
1'-3 1/2"
02
SCALE:
BEADBOARD WAINSCOT
7 3/4"
1/4
MIN.
01
NOT USED
EDGE OF CEDAR TOP
CAP
11 1/2"
SILICONE BEAD AT
PERIMETER (CLEAR)
1'-0"
LINE OF WOOD CUT
PATTERN AT CAP, TYP.
H
2X8 CEDAR CAP
(1" OVERHANG)
W315
5 1/2"
WOOD BASE
WB04
C
Wells
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
DOOR CASING
W/ BACK BAND
BEYOND
2X8 CEDAR CAP
(1" OVERHANG)
W315
5'-0"
HOLD
R
4 0 4 S.
PROJECT NUMBER: 16-059
OPEN FOR
REACH-IN
COOLER
6'-5 1/2"
5'-7"
OPENING IN COOLER
5'-5 1/2"
9"
PARTIAL HGT. WALL
1'-0"
MILLWORK CAP
5'-3 3/4"
R.O.
QUEUING
LINE
2"
8"
MILLWORK CAP
5"
PARTIAL
HGT. WALL
4'-0"
TOP TO WOOD TRIM
W304 OR W317
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
-
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
5'-2"
DOOR FLANGE
10
5'-8 3/4"
DOOR FLANGE
10
A5.0
ROUGH OPENING
WOOD APRON
W309
WALK-IN
WOOD TRIM
COOLER
W313
DOOR CASING
W/ BACK BAND
W300 W319
7 3/4"
7 3/4"
DOOR CASING
W300
WOOD ROSETTE
W316
5'-8 3/4"
7 3/4"
7 3/4"
3 5/8" METAL STUD
WALL, TYP.
1'-0"
MILLWORK CAP
9"
PARTIAL HGT. WALL
2"
BEADBOARD OR
PLYWOOD PANELS AS
NOTED ON INTERIOR
ELEVATIONS
07
A5.0
5'-10"
CHAIR RAIL W305
GC TO PAINT PT-04
SHEET NUMBER
11
BAG-N-BOX
SCALE: 1/2" = 1'-0"
12
CEDAR PANELING
SCALE: 1 1/2" = 1'-0"
13
STANCHION DETAIL
SCALE: 1 1/2" = 1'-0"
14
COOLER BASE
SCALE: 1 1/2" = 1'-0"
15
COOLER JAMB
SCALE: 3" = 1'-0"
A5.0
2/4/2010 2:24:57 PM
7 1/2"
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
03
SCALE:
NOT USED
SCALE:
2'-0"
COMPRESSOR
ALLOW ADEQUATE
SPACE & VENTILATION
FOR TOP MOUNT
COMPRESSOR. GC TO
PROVIDE ACCESS FOR
SERVICE.
REFER TO
CONSTRUCTION PLAN
PHONE
SYSTEM
1'-2"
PRINTER
SHRED
SAFE
3'-2"
2'-2"
2'-3"
FILE
CABINET
1'-6"
3'-8"
NETBOOK
4'-10 1/2"
SERVER
1'-9"
12
POWER
SUPPLY
3'-9 3/4"
6'-0" BLOCKING
MUSIC PLAYER
& AMP
T-STATS
EMPTY
JBOX FOR
FUTURE
DESK TOP
ON WALL
BRACKETS
5/8" DRYWALL
TO BOX
LOCKABLE
CABINET
07
A5.1
SWITCH
VOLUME
CONTROLS
PHONE
CEDAR TOP CAP
DOOR FRAME
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.1 INTERIOR DETAILS.DWG
PROVIDE
BLOCKING
IN WALL
5'-0 3/4"
COOLER OPENING
1/4" TILE TO BOX
PATCH PANEL
1'-2"
OPENING
DATE
04-26-2016
05-23-2016
5/8" FLANGE
6'-0" BLOCKING
3'-6"
1'-9"
1'-9"
J BOX
ADJUSTABLE
SHELF
ON WALL
STANDARDS
ISSUE
DD SET
95% SET
5'-2"
DOOR FLANGE
NOTE: REFER
TO DETAIL
7/E7.0 FOR
POWER & DATA
RECEPTACLE
LOCATIONS
ISSUE DATE
G.C. TO INSTALL
TRIM AFTER DOOR
IS INSTALLED
SCALE: 1/2" = 1'-0"
66 BLOCK
07
SCALE:
SECTION AT COOLER
7'-9"
06
NOT USED
1'-0"
10 1/2"
11 1/2"
5/8" GYP BD TO BOX
5'-3 3/4"
ROUGH OPENING
1/4" TILE TO BOX
5'-7"
5/8" FLANGE
5'-8 1/4"
5'-10"
ROUGH OPEN'G
TILE BAND W/
SEALANT,
NOT GROUT
8'-6"
DOOR FRAME
WALL
MOUNTED
EQUIPMENT
RACK
SHEET TITLE
INTERIOR
DETAILS
MONITOR
ARM
JYOU
SCALE:
NOT USED
SHEET NUMBER
ELEV AT MANAGER DESK
SCALE: 1/2" = 1'-0"
13
NOT USED
SCALE:
14
PLAN AT COOLER
SCALE: 1/2" = 1'-0"
A5.1
3/30/2010 3:45:27 PM
02
PROJECT NUMBER: 16-059
NOT USED
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
01
8'-6" A.F.F.
B.O. GYP. CLG.
CEILING TILE TO RETURN
VERTICALLY TO TOP OF
COOLER
SUSPENDED GRID
SYSTEM
SUSPENDED ACT CEILING
METAL PANELS IN
SUSPENDED GRID
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
10'-6" A.F.F
T.O. FIN. FLOOR
WOOD APRON
W309
FRT WOOD BLOCKING
7'-0" A.F.F.
B.O. HEADER
HALLWAY
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
ALIGN
1/4" SHIM SPACE
A
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
DINING
WALK-IN
COOLER
WOOD CASING
W308
WALL BEYOND
5"
HEADER AT T.R. VESTIBULE
SCALE: 3"=1'-0"
SOFFIT AT COOLER DETAIL
04
SCALE: 1" = 1'-0"
PROVIDE SECONDARY
UNISTRUT FRAMING
TO EXISTING ROOF STRUCTURE
(AS REQUIRED)
05
CLG TRIM DETAIL
SCALE: 3"=1'-0"
PROVIDE SECONDARY
UNISTRUT FRAMING
TO EXISTING ROOF STRUCTURE
(AS REQUIRED)
RIGID CONDUIT FROM CEILING
TO J-BOX
RIGID CONDUIT FROM CEILING
TO J-BOX
GC TO ATTACH CHAIN TO
UNISTRUT
ALL THREAD HARDWARE TO
STABILIZE TRACK FIXTURE TO
UNISTRUT AND TRACK SPACED
AS REQUIRED ALONG TRACK
LENGTH
B.O. J-BOX
12'-9" A.F.F. (SEE NOTE)
B.O. J-BOX
CUSTOM MARKETING SIGN
TO SLIDE IN TO FRAME
J-BOX
J-BOX
LIGHT FIXTURE AS SCHEDULED
TRACK END FEED
LIGHT FIXTURE AS
SCHEDULED
8'-0" A.F.F.
B.O. SIGN
NOTE:
J-BOX AT 11'-6" A.F.F.: INTERIOR
DECORATIVE FIXTURES (L100, L101, L102,
L107, L108)
J-BOX AT 16'-1" A.F.F.: FIXTURE L109
12'-0" A.F.F. (SEE NOTE)
B.O. FIXTURE
SCALE:
07
TRACK FIXTURE MOUNTING
SCALE: 1-1/2"=1'-0"
08
MARKETING HANGING SIGN
SCALE: N.T.S.
PROVIDE SECONDARY
UNISTRUT FRAMING
TO EXISTING ROOF STRUCTURE
(AS REQUIRED)
LIGHT FIXT MOUNTING
09
SCALE: 1 1/2"=1'-0"
PROVIDE SECONDARY
UNISTRUT FRAMING
TO EXISTING ROOF STRUCTURE
(AS REQUIRED). EC TO PROVIDE
BRACING AT STRUCTURE
X'-X" MAX
ALL THREAD HARDWARE TO
STABILIZE TRACK FIXTURE TO
UNISTRUT AND TRACK SPACED
AS REQUIRED ALONG TRACK
LENGTH
PROPELLER & NOSE
13'-0" A.F.F. (SEE NOTE)
B.O. FIXTURE
SCALE: 1 1/2" = 1'-0"
SUSPENDED GRID
SYSTEM
TYP.
TRACK END FEED
LIGHT FIXTURE AS
SCHEDULED
SCALE:
WOOD TRIM CAP
ST-04 W313
METAL PANELS IN
SUSPENDED GRID
12-0" A.F.F. (DECK)
T.O. J-BOX
J-BOX
TRACK FIXTURE MOUNTING
GYP BD UP TO B.O. CEILING
STRUCTURE
EC TO PROVIDE BALL JOINT AT
J-BOX
13'-9" A.F.F. (SEE NOTE)
B.O. J-BOX
12
PROVIDE DIAG METAL STUD
RE-INFORCMENT FROM B.O. SOFFIT
BACK TO STRUCTURE, TYP.
RIGID CONDUIT FROM CEILING
TO J-BOX
J-BOX
NOT USED
SCALE:
DATE
04-26-2016
05-23-2016
3 5/8" STUD SOFFIT WALL AT 16"
O.C. TIED BACK TO DECK, TYP.
12" SPIRAL DUCT
RIGID CONDUIT FROM CEILING
TO J-BOX
11
10
NOT USED
ISSUE
DD SET
95% SET
5 1/2"
06
NOT USED
ISSUE DATE
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.2 INTERIOR DETAILS.DWG
SCALE:
03
13
NOTE:
BOTTOM OF LOWEST PORTION OF
DUCT TO BE AT 10'-0" AFF.
PAINT FINISH TO BE SEMI-GLOSS
GRAPHIC STICKERS TO BE
PROVIDED BY OWNER AND
INSTALLED BY GC
SUBMARINE FINISH DETAIL
SCALE: NTS
10'-0" A.F.F
SWIVEL PLATE
CEILING FAN EXTENSION ROD
AS SCHEDULED
B.O. BULKHEAD
FRT WOOD BLOCKING
1X6 (BEYOND) W309 ST-04
14
CEILING FAN MOUNTING
SCALE: 3"=1'-0"
15
5 1/2"
WOOD APRON
ST-04 W309
CEILING TRIM DETAIL
SCALE: 3"=1'-0"
SHEET TITLE
INTERIOR
DETAILS
JYOU
NOT USED
SHEET NUMBER
A5.2
3/30/2010 3:48:03 PM
SCALE:
02
PROJECT NUMBER: 16-059
NOT USED
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
01
SERVICE
RESTROOM
MARBLE
THRESHOLD
THINSET TO BE
TAPERED @ LAST
TIME COURSE
5"
1/2"
1
4"
1/4"MAX.
MAX.
6"
BULLNOSE TILE
6"
1 38"
1/2" MAX.
1/4"MAX.
1/4" MAX.
WHITE TILE
FT03
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
MOSAIC TILE
QUARRY TILE-SET
IN THIN SET
MORTAR BED
CONCRETE
SLAB
1'-0"
DINING
CAFE DOOR
WHERE OCCURS
1/2" TOTAL
1'-0"
BLACK BORDER TILE
FT04
DINING
WATERPROOFING
MEMBRANE
(WHERE APPLICABLE)
1/8" X 1/8"
SCORING
PER PLAN
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
EXISTING
CONCRETE
SLAB
SCORING PER PLANREFER TO FINISH PLAN
02
EXTERIOR
TRANSITION DETAIL
SCALE: 3"=1'-0"
PREP
04
NOT USED
SCALE:
DINING
DINING
05
MARBLE THRESHOLD
SCALE: 3" = 1'-0"
WOOD OR METAL STUD WALL BEYOND
EXTERIOR
CERAMIC TILE - REFER TO
FINISH SCHEDULE
MOISTURE RESISTANT GYPSUM
BOARD FROM 6" TO CEILING
1/2" TOTAL
WEATHER
STRIPPING
WEATHER
STRIPPING
EXISTING
FOUNDATION
THINSET TO BE
TAPERED @ LAST
TIME COURSE
SEALED CONCRETE
FLOORING
CONTINUOUS WATERPROOFING
6" UP WALL
INTEGRAL QUARRY TILE COVE
BASE W/ BULLNOSE EDGE
QUARRY TILE FLOORING
6"
CONC. SCORING
EXISTING
CONCRETE
SLAB
WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE
BACK WALL AND AT KITCHEN AT NON-SLAB ON GRADE
CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.)
EXISTING
FOUNDATION
NOTE: PROVIDE ANODIZED BRONZE THRESHOLD
NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS
FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/
FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL.
ISSUE DATE
NOTE: PROVIDE ANODIZED BRONZE THRESHOLD
06
TRANSITION DETAIL
SCALE: 3" = 1'-0"
07
NOT USED
SCALE:
08
TRANSITION DETAIL
SCALE: 3"=1'-0"
09
TRANSITION DETAIL
SCALE: 3"=1'-0"
10
QUARRY TILE COVE BASE
SCALE: 3"=1'-0"
FRP - REFER TO FINISH SCHEDULE
(END 2" FROM THE FLOOR)
CERAMIC TILE - REFER TO
FINISH SCHEDULE
MOISTURE RESISTANT GYPSUM
BOARD FROM 6" TO CEILING
MOISTURE RESISTANT GYPSUM
BOARD FROM 6" TO CEILING
CONTINUOUS SEALANT
5/8" DUROCK (6" HIGH)
1'-0"
DUROCK
1'-0"
DUROCK
CONTINUOUS SEALANT
CONTINUOUS WATERPROOFING
6" UP WALL
INTEGRAL QUARRY TILE COVE
BASE W/ BULLNOSE EDGE
QUARRY TILE FLOORING
5/8" DUROCK (6" HIGH)
CONTINUOUS WATERPROOFING
6" UP WALL
BULLNOSE CERAMIC TILE COVE
BASE
CERAMIC TILE & GROUT BED
2"
TAPERED ALUMINUM
FRAME BLACK FINISH
DATE
04-26-2016
05-23-2016
WOOD OR METAL STUD WALL
BEYOND
WOOD OR METAL STUD WALL BEYOND
HELIX WALK OFF MAT BY
GRAND ENTRANCE
ISSUE
DD SET
95% SET
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.3 INTERIOR DETAILS.DWG
EXISTING
CONCRETE
SLAB
CONCRETE
SLAB
5/8" DUROCK (6" HIGH)
1/8"
MAX.
BULLNOSE TILE
1/2"
MAX.
BACKER ROD & SEAL
DOOR- SEE
SCHEDULE
BACKER ROD & SEAL
1/8"
MAX.
HELIX WALK OFF MAT BY
GRAND ENTRANCE
QUARRY TILE-SET
IN THIN SET
MORTAR BED
CONTINUOUS SEALANT
1/2"
MAX.
DOOR- SEE
SCHEDULE
FULL SADDLE ANODIZED
BRONZE THRESHOLD SET
IN CONT. SEALANT BED BY
G.C.- REFER TO FLOOR
FINISH PLAN SHEET
1'-0"
DUROCK
PREP DOOR
WHERE OCCURS
FULL SADDLE ANODIZED
BRONZE THRESHOLD SET
IN CONT. SEALANT BED BY
G.C.- REFER TO FLOOR
FINISH PLAN SHEET
EXISTING
CONCRETE
SLAB
WATERPROOFING THROUGHOUT PREP AREA, SERVICE LINE
BACK WALL AND AT KITCHEN AT NON-SLAB ON GRADE
CONDITIONS ONLY-APPLY TO FACE OF DUROCK 6" HIGH (TYP.)
NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS
FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/
FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL.
SURFACE MOUNTED TAPERED ALUMINUM FRAME
CONTACT LOCAL IMPACT SPECIALTIES FOR MORE INFORMATION.
11
WALK OFF MAT
SCALE: 3" = 1'-0"
12
WALK OFF MAT
SCALE:
13
NOT USED
SCALE:
14
TILE COVE BASE @ FRP
SCALE: 3"=1'-0"
WATERPROOFING THROUGHOUT TOILET ROOM AT
NON-SLAB ON GRADE CONDITIONS ONLY- APPLY TO
FACE OF DUROCK 6" HIGH (TYP.)
NOTE: RUN WATERPROOFING TO TOP OF DUROCK . REFER TO FLOOR PLANS
FOR LOCATIONS. WATERPROOFING TO BE OF CONTINUOUS APPLICATION W/
FLOOR WATERPROOFING FOR TOTAL WATERPROOF SEAL.
15
CERAMIC TILE COVE BASE
SCALE: 3"=1'-0"
SHEET TITLE
INTERIOR
DETAILS
JYOU
DINING
SCALE: 3"=1'-0"
03
SHEET NUMBER
A5.3
3/30/2010 3:53:03 PM
SCALE:
ENLARGED MOSAIC DETAIL
PROJECT NUMBER: 16-059
NOT USED
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
01
3'-0"
ALL SUBSTRATE BEHIND
PANEL REVEALS TO BE
PAINTED BLACK BY G.C.
1 1/2"
3-5/8" METAL STUD @ 16" O.C.
WITH 1/2" PLYWOOD AND
FRP ON SERVICE SIDE (BY
GC)
1"
1 1/2"
1"
WOOD BLOCKING, TYP.
1"
SOLID SURFACE TOP CAP
CN-03 (BY RETAIL, INSTALLED
BY GC) BOLTED TO BLOCKING
FROM UNDERNEATH
1 1/2"
QUARRY TILE BASE
6"
CEMENT BOARD WITH
CERAMIC TILE BASE WB-06
(BY GC)
1"
1'-11"
7 1/4"
CLEAT ATTACHMENT (BY
RETAIL, INSTALLED BY GC)
ON 21" PLYWOOD SUBSTRATE,
5" STRIP (BY GC)
1
2"
04
-
10"
3/4"
SCALE: 1" = 1'-0"
02
1' X 1' ACCESS PANEL (BY GC)
(2) LAYERS 21" PLYWOOD ON 1"
HAT CHANNEL (BY GC) WITH
CERAMIC TILE (WT-11)
9/16"
ORDER/LOAD STATION
SCALE: 1"=1'-0"
03
CHIP CUBBIE
SCALE: 1"=1'-0"
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
CERAMIC TILE WT-11
(PROVIDED AND
INSTALED BY GC)
STAINLESS STEEL TILE EDGE
FINISH TRIM, SCHLUTER
RONDEC OR EQUAL (BY GC)
4 3/4"
7"
STAINLESS STEEL TILE
CORNER FINISH TRIM,
SCHLUTER ECK-K (169 ")
OR EQUAL (BY GC)
A
04
CHIP CUBBIE CORNER DTL
SCALE: 3"=1'-0"
PROJECT NUMBER: 16-059
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ADA COUNTER/POS COUNTER
1" HAT CHANNEL (BY GC)
(2) LAYERS 21" PLYWOOD
ON 1" HAT CHANNEL (BY
GC)
CEMENT BOARD WITH
CERAMIC TILE BASE WB-06
(BY GC)
4 3/4"
7"
CERAMIC TILE WT-11
(PROVIDED AND
INSTALED BY GC)
1
2"
QUARRY TILE BASE (BY GC)
1 1/2"
(2) 3 5/8" METAL STUD @ 16" O.C.
WITH 21" PLYWOOD/FRP ON
SERVICE SIDE (BY GC)
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
5'-0"
8 1/4"
3
4"
9"
CEMENT BOARD WITH
CERAMIC TILE BASE WB-06
(BY GC)
1'-10 1/4"
1'-0"
1
2"
3-5/8" METAL STUD @ 16" O.C.
WITH 1/2" PLYWOOD AND FRP
ON SERVICE SIDE (BY GC)
6"
4'-1 1/2"
4'-2 1/2"
2" DIA. PIPE LEG (BY RETAIL,
INSTALL BY GC) SEE FLOOR
PLAN FOR LOCATION
5"
1-1/2" WOOD PANEL W/ WALL
CLEATS (BY RETAIL,
INSTALLED BY GC)
2'-10"
5"
5"
CLEAT ATTACHMENT (BY
RETAIL, INSTALLED BY GC)
ON 21" PLYWOOD SUBSTRATE,
5" STRIP (BY GC)
3 1/2"
4'-4"
3/4"
CHIP CUBBIE BOLT TO
BLOCKING (BY PSW,
INSTALLED BY GC)
FRP UP BACK OF CHIP
CUBBIE
WOOD BLOCKING, TYP.
3
4"
01
ALL SUBSTRATE BEHIND
PANEL REVEALS TO BE
PAINTED BLACK BY G.C.
9 1/2"
9/16"
SOLID SURFACE
COUNTERTOP CN03 (BY
RETAIL, INSTALL GC)
ISSUE DATE
R:\POTBELLY\16-059 BAL-ELKRIDGE LANDING\DWGS\A\A5.4 INTERIOR DETAILS.DWG
SHEET TITLE
INTERIOR
DETAILS
JYOU
SCALE:
DATE
04-26-2016
05-23-2016
SHEET NUMBER
A5.4
3/30/2010 3:53:03 PM
05
NOT USED
ISSUE
DD SET
95% SET
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
B1-10 CONTRACT DOCUMENTS: WILL BE MADE AVAILABLE FOR REPRODUCTION
AND USE VIA THE POTBELLY FTP SITE.
BIDDING INSTRUCTIONS
B1-01 PROPOSALS
A) PROPOSALS ON COMPLETE WORK ON EACH DIVISION AS DESCRIBED IN
FOLLOWING SPECIFICATIONS, IN SUCH SUBSEQUENT ADDENDA AS MAY BE
ISSUED DURING PERIOD OF BIDDING, AND SHOWN IN ACCOMPANYING
DRAWINGS WILL BE RECEIVED AT THE TIME AND PLACE AS DIRECTED BY
POTBELLY HEREINAFTER REFERRED TO AS POTBELLY REPRESENTATIVE.
B) BASE PROPOSALS ON MATERIALS AND METHODS DESCRIBED IN
SPECIFICATIONS, INCLUDE ALL LOCAL, STATE AND FEDERAL TAXES IN BID.
QUOTE ALL ALTERNATES AND UNIT PRICES LISTED, FOR WHICH PRICE SHALL
BE TOTAL COST TO OWNER INCLUDING ALL OVERHEAD AND PROFIT.
C) LIST SUBCONTRACTORS, MATERIAL SUPPLIERS AND MANUFACTURERS IN
SPACES PROVIDED ON FORM OF PROPOSAL.
B1-02 STANDARDS
A) ARTICLES, DEVICES, MATERIALS, FORMS OF CONSTRUCTION, FIXTURES,
ETC., NAMED IN SPECIFICATIONS TO DENOTE KIND AND QUALITY DESIRED ARE
"STANDARDS". BASE ALL PROPOSALS ON SAME.
B) ANY MAKE OF MATERIALS AND APPARATUS SPECIFIED ACCEPTABLE TO
OWNER, UNLESS OTHERWISE STATED. BASE BID ON ANY MAKE SPECIFIED,
CONTRACTOR NOT REQUIRED TO STATE SELECTION OF SPECIFIED MAKE UNTIL
AFTER AWARD OF CONTRACT, EXCEPT THOSE REQUIRED LISTED ON BID DATE
ON FORM OF PROPOSAL.
C) CONTRACTORS SHALL BID PROJECT USING STANDARDS SPECIFIED.
SUCCESSFUL BIDDER SHALL MAKE WRITTEN APPLICATION FOR APPROVAL OF
OTHER MATERIAL OR APPARATUS WHEN SPECIFICATIONS REFER TO "OR
APPROVED," ETC. BIDDER DESIRING TO PROPOSE SUBSTITUTIONS MAY DO SO
IN ACCORDANCE WITH ARTICLE B1-03 AND SECTION 016000.
B1-03. FINAL APPROVAL OF SUCH PROPOSALS WILL BE THE POTBELLY DIRECTOR
OF CONSTRUCTION.
B1-03 SUBSTITUTIONS
A) IT IS NOT THE INTENT OF SPECIFICATIONS TO EXCLUDE USE OF
MERITORIOUS PRODUCTS OF EQUAL VALUE. EXCEPT WHERE PRODUCTS ARE
SPECIFIED "NO SUBSTITUTION," BIDDERS ARE INVITED TO SUBMIT
SUBSTITUTIONS WITH THEIR BIDS OF OTHER MAKES OF MATERIAL AND
APPARATUS FOR ARCHITECT AND OWNER CONSIDERATION.
B) IF BIDDER PROPOSES SUBSTITUTIONS OF MATERIALS, FIXTURES, ARTICLES,
DEVICES, METHODS OF CONSTRUCTION, ARRANGEMENT OF COMPONENTS, OR
OTHER ITEMS DIFFERENT FROM THOSE CALLED FOR BY DRAWINGS AND
SPECIFICATIONS, BID PRICE FOR SUBSTITUTIONS MUST INCLUDE ALL COSTS
INVOLVED. INCLUDING ANY AND ALL COSTS FOR WORK REQUIRED BY OTHER
CONTRACTORS OR SUBCONTRACTORS NECESSITATED BY PROPOSED
SUBSTITUTION, OR CHANGE. BIDDERS DESIRING CONSIDERATION FOR THE
USE OF MATERIALS, EQUIPMENT, ETC., NOT IN SPECIFICATIONS MAY SUBMIT
PROPOSALS FOR SUBSTITUTIONS OF SAME FOR STANDARDS AS SPECIFIED,
USING "SUBSTITUTION FORM" ATTACHED TO FORM OF PROPOSAL LISTING.
FOR EACH PROPOSED CHANGE (1) "STANDARD" SPECIFIED, (2) SUBSTITUTION,
AND (3) CHANGE IN BID PRICE, (OR "NO CHANGE"). FURNISH OWNER
COMPLETE SPECIFICATIONS AND DESCRIPTION OF PROPOSED SUBSTITUTION
CONSIDERED FOR ACCEPTANCE, UPON REQUEST.
C) SUBSTITUTIONS ACCEPTED MUST BE INCORPORATED IN FORMAL
CONTRACT. NO SUBSTITUTIONS ALLOWED SUBSEQUENT TO AWARD OF
CONTRACT. SUBSTITUTIONS WILL NOT AFFECT DETERMINATION OF LOWEST
BID.
D) IF BIDDER NAMES NO SUBSTITUTE ON HIS "SUBSTITUTION SHEET",
"STANDARDS" SPECIFIED SHALL BE USED. OWNER RESERVES RIGHT TO
ACCEPT ANY ALTERNATE, OR SUBSTITUTION BID PROVIDED SUCH ACTION
TAKEN IN SUFFICIENT TIME NOT TO DELAY PROGRESS OF WORK, OR INCUR
ADDITIONAL EXPENSE TO CONTRACTOR.
B1-04 ADDENDA: LIST ADDENDA ISSUED DURING BIDDING PERIOD ON FORM OF
PROPOSAL, AND IN CLOSING CONTRACT, THEY SHALL BECOME A PART THEREOF.
BIDDER IS RESPONSIBLE FOR TRANSMITTING ADDENDA INFORMATION TO ALL
CONCERNED WITH HIS BID. ACKNOWLEDGE RECEIPT OF ADDENDA IN SPACE
PROVIDED, ON FORM OF PROPOSAL.
B1-05 PROPOSAL FORMS (BID FORMS)
A) SUBMIT PROPOSAL ON FORM PROVIDED, FULLY COMPLETING ALL BLANK
SPACES IN FORM; STATE TOTAL BOTH IN WRITING AND IN FIGURES; SIGNATURE
SHALL BE IN LONGHAND AND COMPLETED FORM SHALL BE WITHOUT
INTERLINEATION, ALTERATION, OR ERASURE. SUBMIT PROPOSALS IN
DUPLICATE, MARKED ON OUTSIDE OF ENVELOPE WITH TITLE OF WORK AND
NAME OF BIDDER. OBTAIN PROPOSAL FORMS FROM POTBELLY
REPRESENTATIVE AND MAIL, OR DELIVER BID PER HIS INSTRUCTIONS.
B) ALL BIDDERS ARE CAUTIONED TO ALLOW AMPLE TIME FOR TRANSMITTAL OF
BIDS. BID RECEIVED AFTER SPECIFIED TIME WILL NOT BE ACCEPTED OR
RECOGNIZED. THE TIME OF RECEIPT WILL DETERMINE THE ACCEPTABILITY OF
MAILED BIDS, REGARDLESS OF POSTMARK.
C) ANY BID MAY BE WITHDRAWN PRIOR TO THE TIME SCHEDULED ABOVE FOR
THE OPENING OF BIDS OR AUTHORIZED POSTPONEMENT THEREOF. NO BID
MAY BE WITHDRAWN FOR THIRTY (30) DAYS, SATURDAYS, SUNDAYS, AND
LEGAL HOLIDAYS EXCLUDED AFTER OPENING OF GENERAL BIDS. NO
TELEPHONE OR TELEGRAPHIC BID, CHANGE IN BID OR WITHDRAWAL BID WILL
BE RECEIVED OR RECOGNIZED.
D) TELEFAX BIDS MAY BE RECEIVED AT OWNER'S OPTION.
B1-11 EXAMINATION OF SITE
A) THE CONTRACTOR SHALL EXAMINE THE SITE, DRAWINGS, SPECIFICATIONS,
AND CONTRACT FORM FOR THE WORK PRIOR TO SUBMITTING PROPOSAL AND
FULLY INFORM HIMSELF OF THE CONDITIONS UNDER WHICH THE WORK MUST
BE COMPLETED AND ASSUME RESPONSIBILITY FOR ANY UNUSUAL AND
UNFORESEEN DIFFICULTIES TO BE OVERCOME IN COMPLETING THE WORK.
B) THE CONTRACTOR AND ALL SUBCONTRACTORS MUST VERIFY DIMENSIONS
AND MEASUREMENTS OF ANY EXISTING CONDITIONS PRIOR TO ORDERING
MATERIALS OR DOING WORK THAT REQUIRES COORDINATION WITH OTHER
TRADES OR EXISTING CONDITIONS. NO CLAIM BASED ON DIFFERENCE
BETWEEN ACTUAL DIMENSIONS AND THOSE SHOWN ON DRAWINGS WILL BE
CONSIDERED.
B1-12 BOND: BIDDER TO WHOM CONTRACT IS AWARDED SHALL QUALIFY TO
EXECUTE, AND SHALL EXECUTE A PERFORMANCE BOND AND LABOR AND
MATERIAL PAYMENT BOND FOR 100% OF AMOUNT OF CONTRACT, IF DIRECTED BY
OWNER. BOND PREMIUMS PAID BY OWNER. FORM UTILIZED SHALL BE CURRENT
EDITION OF AIA FORM A-311. EXECUTE AND DELIVER BOND TO OWNER WITHIN
FIFTEEN (15) DAYS AFTER SIGNING CONTRACT, IF BOND DEEMED NECESSARY.
B1-13 SUBCONTRACTORS, SUPPLIERS, MATERIALS AND EQUIPMENT: LIST NAME,
IN PLACES PROVIDED ON PROPOSAL FORM, ALL SUBCONTRACTORS, SUPPLIERS,
MATERIALS AND EQUIPMENT REQUESTED ON WHOM OR WHICH BID IS BASED AND
WHOM BIDDER INTENDS TO EMPLOY OR WHICH HE INTENDS TO USE. COMPLETE
ALL SPACES IN FORM OF PROPOSAL. SEE SUPPLEMENTARY GENERAL
CONDITIONS, ARTICLE 28.
B1-14 BIDDING PROCEDURE
A) SUBMIT BIDS USING APPROVED PROPOSAL FORMS, COPIES ARE AVAILABLE
FROM POTBELLY REPRESENTATIVE. COMBINED PROPOSAL IS INVITED ON
ENTIRE CONTRACT INCLUDING GENERAL CONTRACT, PLUMBING, HEATING, AIR
CONDITIONING AND VENTILATING, AND ELECTRICAL. SUBMIT AS ONE TOTAL
CONTRACT AMOUNT IN SPACE PROVIDED ON FORM OF PROPOSAL. SUBMIT
PROPOSAL ON OWNER SUPPLIED "FORM OF PROPOSAL" UNDER THIS FORM,
CONTRACT AMOUNT IF FIXED AND CONTRACTOR GUARANTEES A LIMIT OF
CONSTRUCTION COST.
B) BIDS BY INVITATION ONLY. OWNER RESERVES RIGHT TO REJECT ANY, OR
ALL BIDS.
C) BIDDERS AND THEIR PROPOSED SUBCONTRACTORS COMPETENCY AND
RESPONSIBILITY WILL BE CONSIDERED IN MAKING AWARD.
B1-15 UTILITY COMPANIES REGULATIONS COMPLY WITH REGULATIONS OF LOCAL
UTILITY COMPANIES PRIOR TO SUBMISSION OF PROPOSAL. DETERMINE FROM
EACH UTILITY COMPANY SUPPLYING SERVICE TO PROJECT ALL REQUIREMENTS
AND INCLUDE COST OF SAME IN BID COST OF RELOCATION OF UTILITIES SERVICE
LINES INTERFERING WITH CONSTRUCTION SHALL BE INCLUDED IN CONTRACTOR'S
PROPOSAL.
B1-07 EXAMINATION OF DOCUMENTS: BIDDERS EXAMINE ALL CONTRACT
DOCUMENTS, INCLUDING ALL DRAWINGS AND SPECIFICATIONS FOR ALL DIVISIONS
OF WORK AS WELL AS HIS OWN, NOTING PARTICULARLY ALL REQUIREMENTS
WHICH AFFECT HIS WORK IN ANYWAY. FAILURE OF BIDDER TO ACQUAINT HIMSELF
WITH QUANTITY AND CHARACTER OF WORK REQUIRED TO COMPLETE HIS
DIVISION OF CONTRACT IN CONFORMITY WITH ALL REQUIREMENTS FOR PROJECT
WILL NOT BE CONSIDERED AS BASIS FOR EXTRA COMPENSATION.
B1-08 INQUIRIES: SHOULD BIDDER FIND DISCREPANCIES OR OMISSIONS IN
DRAWINGS OR SPECIFICATIONS, OR HAVE DOUBT OF THEIR MEANING, NOTIFY
ARCHITECT OR POTBELLY REPRESENTATIVE AT ONCE. ARCHITECT WILL ISSUE
WRITTEN INSTRUCTIONS TO ALL BIDDERS REGARDING SAME. NEITHER
ARCHITECT, NOR POTBELLY REPRESENTATIVE WILL BE RESPONSIBLE FOR ANY
ORAL INSTRUCTIONS. INQUIRIES IN REGARD TO BID SHALL BE MADE MINIMUM OF
ONE (1) WEEK PRIOR TO BID RECEIPT DATE.
B1-09 CONTRACT AWARD: OWNER WILL CONSIDER COMPETENCY AND
RESPONSIBILITY OF BIDDERS AND SUBCONTRACTORS IN MAKING AWARD. OWNER
ARTICLE 2 - DEFINITIONS: NOTICES:
CONTRACT DOCUMENTS
A) OWNER-CONTRACTOR AGREEMENT.
B) GENERAL CONDITIONS:
C) SUPPLEMENTARY GENERAL CONDITIONS: (IN SPECIFICATIONS, OF WHICH
THIS IS A PART.)
D) GENERAL SPECIFICATIONS.
E) DRAWINGS AND ISSUED ADDENDA.
OWNER
WHERE REFERENCED IN THE SPECIFICATIONS, THE "OWNER" OR "OWNER'S
REPRESENTATIVE" SHALL MEAN "THE OWNER'S DIRECTOR OF CONSTRUCTION,"
AS DESIGNATED IN THE EXECUTED OWNER-CONTRACTOR AGREEMENT.
POTBELLY SANDWICH SHOP
222 MERCHANDISE MART PLAZA
23RD FLOOR
CHICAGO, ILLINOIS 60654
312.951.0600
ARCHITECT
AS NAMED ON COVER SHEET
CONTRACTOR
AS NAMED IN CONSTRUCTION CONTRACT, UNLESS OTHERWISE DEFINED, SUCH
AS GENERAL CONTRACTOR OR ELECTRICAL CONTRACTOR, TERM
CONTRACTOR SHALL BE UNDERSTOOD TO MEAN ANY CONTRACTOR OR
CONTRACTORS WHO HAVE ENTERED INTO SEPARATE CONTRACT WITH OWNER.
B1-16 CODES AND RESTRICTIONS THIS BUILDING DESIGN IS BASED UPON LOCAL
BUILDING CODES. SHOULD PROVISIONS OF PREVAILING LOCAL BUILDING
AUTHORITIES OR CODES GOVERNING AREA FOR CONSTRUCTION OF THIS
BUILDING DIFFER FROM THOSE PROVISIONS OF THE LOCAL CODE, IT WILL BE THE
RESPONSIBILITY OF BIDDER TO ADVISE ARCHITECT IMMEDIATELY OF SAME AND
TO BID PROJECT ACCORDING TO GOVERNING CODES. AN ADDENDUM WILL BE
ISSUED INSTRUCTING ALL BIDDERS.
GENERAL CONTRACTOR
AS NAMED IN CONSTRUCTION CONTRACT. CONTRACTOR FOR ALL OF WORK
EXCEPT THOSE PARTS FOR WHICH OWNER HAS CONTRACTED SEPARATELY.
CONTRACT FORMS
REQUEST FOR QUOTATION
LETTER OR FORM ISSUED AFTER AWARD OF CONTRACT REQUESTING CHANGE
OR AMENDMENT OF CONTRACT DOCUMENTS. CHANGE ORDER IS ISSUED,
FROM THIS INFORMATION.
DIVISION B - CONSTRUCTION CONTRACT FORM: FURNISHED BY THE GENERAL
CONTRACTOR. UNLESS OTHERWISE AGREEABLE TO THE OWNER, USE AIA 107 AGREEMENT BETWEEN OWNER AND CONTRACTOR FOR A PROJECT OF LIMITED
SCOPE, MODIFIED TO INCORPORATE THE GENERAL AND SUPPLEMENTARY
CONDITIONS HEREIN..
PERFORMANCE BOND: PERFORMANCE AND MATERIALS BOND SHALL BE
EXECUTED ON AMERICAN INSTITUTE OF ARCHITECTS PERFORMANCE BOND. A.I.A.
DOCUMENT NUMBER 311, CURRENT EDITION. THIS FORM IS AVAILABLE FOR
INSPECTION IN ARCHITECT'S OFFICE AND IS NOT BOUND WITHIN THIS SET OF
SPECIFICATIONS. BOND SHALL BE IN THE AMOUNT OF 100% OF CONTRACT; BOND
TO BE PAID BY OWNER, IF REQUIRED.
B) CONTRACTOR LIABLE AND RESPONSIBLE FOR MAKING, AT HIS OWN
EXPENSE, ANY AND ALL REPAIRS REQUIRED BY REASON OF DAMAGE
RESULTING FROM PERFORMANCE, NON-PERFORMANCE OR IMPROPER
PERFORMANCE OF WORK PROVIDED; HOWEVER, THAT CONTRACTOR SHALL
NOT REPAIR ANY DAMAGE DIRECTLY CAUSED SOLELY BY ACTS OF OWNER. IF
REPAIRS ARE NOT PROMPTLY MADE, OWNER MAY MAKE REPAIRS AND DEDUCT
COSTS FROM AMOUNTS OTHERWISE DUE TO CONTRACTOR AT THAT TIME OR
BILL CONTRACTOR FOR SAID COSTS.
C) CONTRACTOR TAKE WHATEVER PRECAUTIONS ARE NECESSARY TO
PROTECT PREMISES BELONGING TO OWNER COMPRISING OR BEING IN VICINITY
THEREOF, SO AS TO SAFEGUARD ALL STRUCTURES, FIXTURES, FURNISHINGS
AND EQUIPMENT LOCATED THEREON. PROTECT ALL ADJACENT PROPERTY AND
PROPERTY IN VICINITY FROM DAMAGE. HOLD OWNER HARMLESS FROM ANY
DAMAGES.
ARTICLE 6 - CONTRACTOR'S RESPONSIBILITY
CONTRACTOR AGREES TO INDEMNIFY OWNER AGAINST ANY AND ALL CLAIMS,
LOSS, DAMAGE, COSTS AND EXPENSE ARISING FROM INJURY TO OR DEATH OF
PERSONS OR DAMAGE TO PROPERTY AND EMPLOYEES OF OWNER,
OCCURRING, WHOLLY OR IN PART, AS RESULT OF WORK DONE OR OMITTED, OR
CONTRACTED TO BE DONE; BUT, NOT DONE BY CONTRACTOR OR HIS
SUBCONTRACTORS, IF ANY, OR EMPLOYEES OR AGENTS OR INVITEES OF
CONTRACTOR OR ANY SUBCONTRACTORS, REGARDLESS OF WHETHER ANY
SUCH INJURY TO OR DEATH OF PERSONS OR DAMAGE TO OR DESTRUCTION OF
PROPERTY IS DUE OR CLAIMED TO BE DUE, IN WHOLE OR IN PART, TO ANY
NEGLIGENCE OR FAULT OF OWNER OR HIS EMPLOYEES, AGENTS OR INVITEES,
EXCEPT CLAIMS, LOSS, DAMAGE, COSTS OR EXPENSE RESULTING SOLELY
FROM THE WILLFUL ACTION OF OWNER.
ADDENDUM
LETTER OR FORM CLARIFYING, AMENDING, OR INTERPRETING CONTRACT
DOCUMENTS ISSUED BEFORE RECEIPT OF BIDS.
CHANGE ORDER
LETTER OR FORM AUTHORIZING CHANGES IN THE CONTRACT DOCUMENTS
EXECUTED PER THE GENERAL CONDITIONS.
FIELD ORDER
LETTER OR FORM AUTHORIZING CHANGES WHICH DO NOT CHANGE THE
CONTRACT AMOUNT.
WORK
ALL THAT WHICH SHALL BE DONE, PER ARTICLE 1 OF GENERAL CONDITIONS.
OWNER NOT RESPONSIBLE IN ANY MANNER FOR THE PROPERTY OF
CONTRACTOR, CONTRACTOR'S EMPLOYEES, OR SUBCONTRACTORS OR
SUBCONTRACTOR'S EMPLOYEES.
ARTICLE 7 - PAYMENTS BY CONTRACTOR
CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS REQUIRED FOR
WORK AND SHALL PAY FOR ALL FEES, TAXES, ROYALTIES, RENTS, PENALTIES
AND CHARGES AS MAY BE REQUIRED FOR WORK EXCEPT AS HEREINAFTER
SPECIFICALLY PROVIDED. OWNER RESERVES RIGHT TO TAKE OUT ANY, OR ALL
PERMITS. THESE PAYMENTS SHALL BE IN ADDITION TO ANY PAYMENTS TO
OWNER UNDER ANY TERMS, CONDITION, OR PROVISION OF CONTRACT
DOCUMENTS. OWNER WILL PAY ALL REAL ESTATE ASSESSMENTS AND REAL
ESTATE TAXES. SIGN PERMIT SHALL BE OBTAINED BY SIGN CONTRACTOR AT
HIS EXPENSE.
SPECIAL INSPECTIONS REQUIRED UNDER PROVISIONS OF BUILDING CODE OR
UTILITY COMPANY REGULATIONS ARRANGED AND PAID FOR BY CONTRACTOR.
ARTICLE 9 - MEASUREMENTS
BEFORE ANY MATERIAL IS FABRICATED, CONTRACTOR AND EACH
SUBCONTRACTOR SHALL TAKE ALL NECESSARY MEASUREMENTS AND LAY OUT
WORK INCLUDED IN HIS CONTRACT, AND SHALL BE RESPONSIBLE FOR PROPER
FITTING AND ACCURACY.
ARTICLE 10 - MATERIALS
PLACE ORDERS FOR MATERIALS AND EQUIPMENT TO BE EMPLOYED IN WORK;
OTHER THAN THOSE DESIGNATED FURNISHED BY OWNER, AS SOON AS
POSSIBLE AFTER AWARD OF CONTRACT. CONTRACTOR SHALL KEEP OWNER,
ARCHITECT, AND POTBELLY REPRESENTATIVE INFORMED AS TO AVAILABILITY
OF ALL SPECIFIED MATERIALS AND EQUIPMENT, ADVISE THEM PROMPTLY IN
WRITING OF ALL ORDERS PLACED, AND OF SUCH MATERIALS AND EQUIPMENT
AS MAY NOT BE OBTAINABLE FOR PURPOSES OF CONTRACT, WHETHER DUE TO
CONDITIONS OF MARKET OR OTHER LIMITING AND GOVERNING FACTORS.
ARTICLE 3 - ABBREVIATIONS
ARTICLE 11 - WARRANTY OF TITLE
DIVISION C - GENERAL CONDITIONS
GENERAL CONDITIONS OF CONTRACT FOR CONSTRUCTION - CONSTRUCTION
MANAGER AS ADVISOR, AS PUBLISHED BY THE AMERICAN INSTITUTE OF
ARCHITECTS, AIA DOCUMENT NUMBER A-232, 2009 EDITION, SHALL APPLY TO
GENERAL CONTRACT AS WELL AS ALL SUBCONTRACTS, EXCEPT AS SAID GENERAL
CONDITIONS MAY BE ABROGATED, AMPLIFIED, MODIFIED, OR NULLIFIED BY
SUPPLEMENTARY GENERAL CONDITIONS, CONTAINED IN THESE SPECIFICATIONS,
SAID GENERAL CONDITIONS AND SAID SUPPLEMENTARY GENERAL CONDITIONS
HAVE BEEN CAREFULLY READ AND CONSIDERED PART OF THE SPECIFICATIONS.
SUPPLEMENTARY GENERAL CONDITIONS
A) CONTRACTOR PROVIDES ALL ITEMS, ARTICLES, MATERIALS, OPERATIONS
OR METHODS INDICATED ON PLANS, SECTIONS AND/OR DETAILS, INCLUDING
ALL LABOR, MATERIALS, EQUIPMENT AND INCIDENTALS REQUIRED OR
NECESSARY FOR THEIR COMPLETION.
B) CALL ERRORS OR INCONSISTENCIES IN DRAWINGS OR SPECIFICATIONS TO
THE ATTENTION OF THE ARCHITECT OR POTBELLY REPRESENTATIVE FOR
PROPER ADJUSTMENT. DO NOT PROCEED WITH WORK IN CASES OF
UNCERTAINTY.
C) CONTRACTOR AGREES THAT WORK HEREIN DESCRIBED SHALL BE
COMPLETE IN EVERY DETAIL, EVEN THOUGH EVERY ITEM NECESSARILY
INVOLVED IS NOT PARTICULARLY MENTIONED. CONTRACTOR SHALL PROVIDE
ALL LABOR AND MATERIALS NECESSARY FOR COMPLETION OF WORK
DESCRIBED IN CONTRACT DOCUMENTS, AND NOT AVAIL HIMSELF OF ANY
MANIFESTLY UNINTENTIONAL ERROR OR OMISSION SHOULD SUCH EXIST.
D) SHOULD CONTRACT DOCUMENTS DISAGREE AS TO QUALITY OR QUANTITY
OF WORK, PROVIDE BETTER QUALITY OR GREATER QUANTITY UNLESS
INSTRUCTED OTHERWISE BY ARCHITECT IN WRITING.
E) CERTAIN SPECIFICATIONS AND CERTAIN OF OTHER CONTRACT DOCUMENTS,
INCLUDING THESE GENERAL CONDITIONS, ARE OF SIMPLIFIED TYPE AND
INCLUDE INCOMPLETE SENTENCES. OMISSION OF WORDS OR PHRASES, SUCH
AS "THE CONTRACTOR SHALL", "IN CONFORMITY THEREWITH", "SHALL BE", "AS
NOTED", "A", "AN", "THERE", AND "ALL" ARE INTENTIONAL. OMITTED WORDS
SHALL BE SUPPLIED INFERENCE IN SAME MANNER AS THEY ARE WHEN A NOTE
OCCURS ON DRAWINGS, WORDS "SHALL BE" OR "SHALL BE SUPPLIED" BY
INFERENCE PARTICULARLY WHEN A COLON OR HYPHEN IS USED WITHIN
SENTENCE OR PHRASES.
REFERENCE TO TECHNICAL SOCIETY'S ORGANIZATION BODIES OR DOCUMENTS IS
MADE IN SPECIFICATIONS IN ACCORDANCE WITH FOLLOWING ABBREVIATIONS:
AIA AMERICAN INSTITUTE OF ARCHITECTS
ACI AMERICAN CONCRETE INSTITUTE
AIEE AMERICAN INSTITUTE OF ELECTRICAL ENGINEERS
AHJ AUTHORITY HAVING JURISDICTION
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ASA AMERICAN STANDARDS ASSOCIATION
ASLA AMERICAN SOCIETY OF LANDSCAPE ARCHITECTS
ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AWI ARCHITECTURAL WOODWORK INSTITUTE
AWSC AMERICAN WELDING SOCIETY CODE
FS FEDERAL SPECIFICATIONS
ICC INTERNATIONAL CODE COUNCIL
NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NBS NATIONAL BUREAU OF STANDARDS
NEC NATIONAL ELECTRICAL CODE
SJI STEEL JOIST INSTITUTE
SPR SIMPLIFIED PRACTICE RECOMMENDATION
UL UNDERWRITER'S LABORATORIES, INC.
BOCA BUILDING OFFICIALS CODE ASSOCIATION
UBC UNIFORM BUILDING CODE
SBCCI STANDARD BUILDING CODE CONGRESS INTERNATIONAL
NO MATERIALS, SUPPLIES, OR EQUIPMENT INCORPORATED IN WORK SHALL BE
PURCHASED SUBJECT TO ANY CHATTEL MORTGAGE OR UNDER A CONDITIONAL
SALE OR OTHER AGREEMENT BY WHICH AN INTEREST THEREIN, OR IN ANY
PART THEREOF, IS RETAINED BY SELLER, SUPPLIER, OR MANUFACTURER.
ARTICLE 12 - MOVING OF MATERIALS
IF IT BECOMES NECESSARY DURING PROGRESS OF WORK TO MOVE MATERIALS
WHICH ENTER INTO CONSTRUCTION, OR EQUIPMENT TEMPORARILY PLACED,
CONTRACTOR FURNISHING SAME SHALL, WHEN DIRECTED BY POTBELLY, MOVE
THEM WITHOUT COST TO OWNER.
ARTICLE 13 - WORKMEN AND WORKMANSHIP
A) CONTRACTOR MAINTAIN ORDER AND DISCIPLINE AMONG WORKMEN AT ALL
TIMES.
B) WORKMANSHIP: ONLY ARTISANS AND MECHANICS QUALIFIED THROUGH
EXPERIENCE IN THEIR RESPECTIVE BRANCHES SHALL EXECUTE OR PERFORM
WORK. ARCHITECT, OR POTBELLY REPRESENTATIVE IS NOT ON JOB SITE AT
ALL TIMES; HOWEVER, WORK INSTALLED CONTRARY TO CONTRACT
DOCUMENTS SHALL BE REMOVED AND REPLACED WITHOUT DELAY, IN
CONFORMITY WITH CONTRACT DOCUMENTS WHEN DIRECTED BY ARCHITECT,
OR POTBELLY REPRESENTATIVE WITHOUT ADDITIONAL COST TO OWNER.
C) WORKMEN NOT COMPLYING WITH PROVISIONS OF CONTRACT DOCUMENTS
SHALL BE IMMEDIATELY REMOVED BY CONTRACTOR FROM ANY PREMISES
BELONGING TO OWNER UPON NOTICE OF ARCHITECT OR POTBELLY
REPRESENTATIVE.
ARTICLE 4 - CODES AND STANDARDS
ARTICLE 14 - PROSECUTION OF WORK
MATERIAL SUPPLIERS SUBMIT EVIDENCE, IF REQUESTED, MATERIAL IN
QUESTION COMPLIES WITH APPLICABLE CURRENT CODES AND STANDARDS AS
REFERRED TO IN SPECIFICATIONS.
ARTICLE 5 - DAMAGE RESULTING FROM WORK
A) GENERAL CONTRACTOR/CONTRACTOR IS SOLELY RESPONSIBLE FOR
EXPENSES INCURRED OR DAMAGE CAUSED BY DEFECTIVE OR ILLTIMED WORK
PERFORMED OR WHICH HE FAILS TO PERFORM PER HIS CONTRACT.
BEFORE STARTING AND INTERMITTENTLY AS WORK PROGRESSES,
CONTRACTOR AND SUBCONTRACTORS EXAMINE WORK INSTALLED BY OTHERS
INSOFAR AS IT APPLIES TO HIS WORK AND PROMPTLY NOTIFY ARCHITECT OR
POTBELLY REPRESENTATIVE IF CONDITIONS EXIST THAT PREVENT HIM GIVING
SATISFACTORY RESULTS.
IT IS DUTY OF CONTRACTOR TO NOTIFY VARIOUS SUBCONTRACTORS WHEN
THEIR PRESENCE IS REQUIRED, EXPEDITE FLOW OF MATERIALS AND SECURE
NECESSARY INSPECTIONS. CONTRACTOR SHALL REQUIRE THAT ALL
SUBCONTRACTORS HAVE COMPETENT SUPERVISOR ON SITE WHENEVER HIS
WORK IS BEING PERFORMED. CONTRACTOR SHALL GIVE REASONABLE NOTICE
TO ARCHITECT AND POTBELLY REPRESENTATIVE WHEN HIS PRESENCE IS
REQUIRED FOR SPECIAL CONSULTATIONS, EXAMINATIONS, OR DECISIONS.
ARTICLE 15 - EXAMINATION
WORK, OPERATION AND MAINTENANCE MANUALS PERTAINING TO ALL
MECHANICAL EQUIPMENT FURNISHED AND/OR INSTALLED UNDER CONTRACT.
FAILURE TO FURNISH SUCH MANUALS WITHIN ALLOTTED TIME LIMIT WILL CAUSE
SAID CONTRACTOR TO BE LIABLE FOR DAMAGES RESULTING FROM MISUSE OF
SAID EQUIPMENT.
ARTICLE 26 - NOTICES
ARTICLE 16 - PROTECTION OF MATERIALS
A) PROTECT PRE FINISHED MATERIALS OR MATERIALS FINISHED IN PLACE
WHEN INSTALLED BEFORE COMPLETION OF WORK FROM DAMAGE UNTIL
ACCEPTANCE OF PROJECT. REPLACE MATERIALS DAMAGED BEFORE OR AFTER
INSTALLATION WITH NEW AND UNDAMAGED FINISHED MATERIALS. REFINISH, OR
REPLACE AND FINISH, MATERIALS AFTER INSTALLATION WHICH ARE DAMAGED
AS DIRECTED. ADDITIONAL CHARGES ARE NOT HONORED BY OWNER FOR
REPLACEMENT OR REPAIR OF DAMAGED MATERIALS.
B) PROVIDE SECURITY AND FACILITIES TO PROTECT WORK, AND EXISTING
FACILITIES, AND OWNER'S OPERATIONS FROM UNAUTHORIZED ENTRY,
VANDALISM, OR THEFT.
ARTICLE 17 - NO WAIVER BY OWNER
FAILURE OF OWNER IN ONE OR MORE INSTANCES TO INSIST UPON STRICT
PERFORMANCE OF ANY TERMS OF CONTRACT OR TO EXERCISE ANY OPTION
HEREIN CONFERRED, SHALL NOT BE CONSTRUED AS WAIVER OR
RELINQUISHMENT TO ANY EXTENT OF RIGHT TO ASSERT OR RELY UPON ANY
SUCH TERMS OR OPTION ON ANY FUTURE OCCASION.
ARTICLE 18 - SUSPENSION OF WORK
CONTRACTOR SHALL BEAR ALL LOSSES OCCURRING BY REASON OF THEFT OR
LOSS, OR DAMAGE, REGARDLESS OF CAUSE, TO:
A) ALL MATERIALS, SUPPLIES, EQUIPMENT AND APPARATUS OWNED, USED OR
FURNISHED, REGARDLESS OF WHETHER OF NOT SAID MATERIALS, SUPPLIES,
EQUIPMENT OR APPARATUS ARE INCLUDED IN ITEMS TO BE FURNISHED OR
USED HEREUNDER OR TO BE INCORPORATED IN WORK, PRIOR TO WORK'S
COMPLETIONS.
B) ALL OF CONTRACTOR'S TOOLS, MACHINERY, EQUIPMENT, MATERIALS,
SUPPLIES, APPLIANCE, SHORING, SCAFFOLDING, FALSE WORK AND SHED AND
PERSONAL PROPERTY OF CONTRACTOR'S EMPLOYEES.
ARTICLE 8 - SPECIAL INSPECTIONS
GENERAL CONDITIONS
ARTICLE 1 - DRAWINGS AND SPECIFICATIONS
B1-06 EXAMINATION OF PREMISES: PRIOR TO SUBMITTING PROPOSAL, BIDDER
WILL EXAMINE PREMISES AND SATISFY HIMSELF AS TO CONDITIONS UNDER
WHICH HE SHALL BE OBLIGED TO OPERATE IN PERFORMING WORK, OR THOSE
CONDITIONS WHICH AFFECT HIS WORK. BIDDERS VISIT AND EXAMINE SITE TO
INFORM THEMSELVES OF SITE CHARACTERISTICS AND CIRCUMSTANCES
AFFECTING COST OF WORK AND TIME REQUIRED FOR EXECUTION OF CONTRACT.
BIDDERS WHOLLY RESPONSIBLE FOR ERRORS AFFECTING COST OF WORK AND
TIME REQUIRED FOR EXECUTION, AS WELL AS ERRORS WHICH MAY OCCUR IN
THEIR PROPOSAL DUE TO FAILURE TO MAKE SUCH VISITS AND EXAMINATIONS.
F) WORD "PROVIDE" SHALL BE UNDERSTOOD TO MEAN "FURNISH" INSTALL AND
(IF APPLICABLE) PLACE IN OPERATION" UNLESS OTHERWISE STATED. WORDS
"DIRECTED", "SELECTED", "APPROVED", "REQUIRED", "PERMITTED", "ACCEPTED",
SHALL BE UNDERSTOOD TO MEAN DIRECTION, SELECTION, APPROVAL,
REQUIREMENTS OR PERMISSION, RESPECTIVELY OF THE OWNER'S DIRECTOR
OF CONSTRUCTION,, UNLESS OTHERWISE STATED.
G) SPECIFICATIONS ARE ARRANGED IN SECTIONS, BUT SUCH SEGREGATION
SHALL NOT BE CONSIDERED AS LIMITING WORK REQUIRED BY ANY TRADE.
DIVISION OF WORK SHALL BE THE RESPONSIBILITY OF CONTRACTOR.
H) DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. EXCEPT AS
FOLLOWS, WHAT IS CALLED FOR BY ONE SHALL BE CONSIDERED AS CALLED
FOR BY BOTH.
1) WHERE FINISHES NOT INDICATED ON THE DRAWING FINISH PLANS,
ELEVATIONS, OR NOTES ARE INDICATED IN THE FINISH LEGEND, SUCH
FINISHES SHALL NOT BE REQUIRED.
2) WHERE HARDWARE NOT REFERENCED ON THE DOOR SCHEDULE IS
INDICATED IN HARDWARE GROUP SCHEDULE, SUCH HARDWARE SHALL NOT
BE REQUIRED.
3) ALL MATERIALS, PROCEDURES, AND COMPLIANCE REQUIREMENTS
REASONABLY NECESSARY FOR CONSTRUCTION OF A COMPLETE AND
FUNCTIONING FACILITY IN ACCORDANCE WITH DESIGN INTENT SHALL BE
REQUIRED, REGARDLESS OF EXTENT OF DOCUMENTATION.
IF WHOLE OR PART OF WORK IS SUSPENDED CONTRACTOR SHALL, AT HIS OWN
EXPENSE, COVER, SECURE AND PROTECT ALL PARTS OF HIS WORK THAT
MIGHT BE INJURED FROM ANY CAUSE.
ARTICLE 19 - STOPPAGE OF WORK
IN EVENT OWNER IS PERMANENTLY ENJOINED OR OTHERWISE STOPPED FROM
COMPLETING THIS CONTRACT, OWNER IS LIABLE TO CONTRACTOR FOR ONLY
WORK ACTUALLY PERFORMED AND MATERIALS AT SITE LESS SALVAGE VALUE
THEREOF. SCHEDULE OF VALUES OF CONTRACT SUBMITTED AT TIME
CONTRACT IS SIGNED WILL BE USED AS A BASIS OF SETTLEMENT.
ARTICLE 20 - CLEANING UP
A) EACH CONTRACTOR, UPON COMPLETION OF HIS WORK, COLLECT AND
REMOVE ALL RUBBISH, SURPLUS MATERIALS, TOOLS, AND SCAFFOLDING. KEEP
PREMISES NEAT AND ORDERLY BY PERIODIC REMOVAL AND CLEANUP.
REMOVE CRATES AND CARTONS IN WHICH MATERIALS, EQUIPMENT OR
FIXTURES ARE RECEIVED DAILY.
B) IF, IN OPINION OF ARCHITECT, POTBELLY REPRESENTATIVE, OR GENERAL
CONTRACTOR, NEATNESS IS NOT MAINTAINED, POTBELLY REPRESENTATIVE OR
GENERAL CONTRACTOR MAY HAVE AREA CLEANED AND CHARGE COSTS TO
RESPONSIBLE CONTRACTORS.
C) AT COMPLETION OF BUILDING OR ANY PART THEREOF, GENERAL
CONTRACTOR, IN ADDITION TO REMOVAL OF ACCUMULATED RUBBISH, SHALL
REPLACE ANY BROKEN GLASS, REMOVE STAINS, SPOTS AND MARKS FROM
FINISH WORK AND HARDWARE.
D) REMOVE ALL STICKERS AND LEAVE BUILDING IN A CLEAN CONDITION.
ARTICLE 21 - GUARANTEE
UNLESS OTHERWISE SPECIFIED, CONTRACTOR GUARANTEES ALL MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM DATE OF
ACCEPTANCE OF BUILDING, AND SHALL REPLACE OR SATISFACTORILY REPAIR,
WITHOUT COST TO OWNER OR INTERFERENCE WITH OWNER'S OPERATION,
ANY DEFECTIVE WORKMANSHIP OR MATERIALS. ADDITIONAL REPLACEMENTS
OR REPAIRS, WITHOUT LIMITATION, SHALL BE MADE BY CONTRACTOR WITHOUT
COST TO OWNER UNTIL ALL DEFECTIVE WORKMANSHIP OR MATERIALS HAVE
BEEN CORRECTED AND THE WORK COMPLETED IN ACCORDANCE WITH
CONTRACT DOCUMENTS EVEN IF THE ONE (1) YEAR PERIOD ABOVE SPECIFIED
HAS EXPIRED IF OWNER HAS GIVEN CONTRACTOR NOTICE OR ORIGINAL
FAILURE OF COMPLIANCE WITH CONTRACT DOCUMENTS IS PRIOR TO
EXPIRATION OF SAID PERIOD.
ARTICLE 22 - JOB MEETINGS
1. PRECONSTRUCTION MEETING: THE OWNER WILL ADMINISTER
PRECONSTRUCTION MEETING FOR EXECUTION OF THE OWNER-CONTRACTOR
AGREEMENT (IF NOT PREVIOUSLY COMPLETED) AND EXCHANGE OF
PRELIMINARY SUBMITTALS. AGENDA SHALL INCLUDE THE FOLLOWING.
A. IDENTIFICATION AND INTRODUCTION OF OWNER, ARCHITECT, DIRECTOR
OF CONSTRUCTION, CONTRACTOR, PRINCIPLE SUBCONTRACTORS,
LANDLORD, AND OTHER KEY PERSONNEL
B. CLARIFICATION RESPONSIBILITIES IN USE OF SITE.
C. PROJECT SCHEDULE, INCLUDING SCHEDULE FOR CRITICAL SUBMITTALS,
RESUBMITTALS, PAY APPLICATIONS, TESTING AND INSPECTIONS, AND
PROGRESS MEETINGS.
D. QUALITY ASSURANCE.
E. SUBMITTAL REQUIREMENTS, INCLUDING FORMAT, RECIPIENTS, REVIEW
PROCESSES, AND TURNAROUND.
F. MOCK-UPS: SCHEDULE, TYPE, LOCATION, APPROVAL CRITERIA, AND
REMOVAL.
G. TARGETS AND VERIFICATION OF SUSTAINABLE CONSTRUCTION
MATERIALS AND PRACTICES.
H. TIMING, NOTIFICATION, SUBMITTAL REQUIREMENTS, HANDLING, AND
COORDINATION OF OWNER FURNISHED ITEMS.
I. COMMUNICATION AND RECORDKEEPING.
2. GENERAL CONTRACTOR SCHEDULE SEMIMONTHLY PROGRESS MEETING
BETWEEN HIMSELF, SEPARATE CONTRACTORS, AND MAJOR
SUBCONTRACTORS. NOTIFY POTBELLY REPRESENTATIVE OF TIME OF MEETING
WHICH SHALL BE SAME HOUR AND DAY OF WEEK FOR DURATION OF WORK.
GENERAL CONTRACTOR MUST TAKE AND DISTRIBUTE MINUTES OF ALL
MEETINGS, TO SUBCONTRACTORS, SEPARATE CONTRACTORS AND POTBELLY
REPRESENTATIVE.
ARTICLE 23 - MATERIALS AND SUBCONTRACTORS
CONTRACTOR EMPLOY SUBCONTRACTORS AND FURNISH MATERIALS NAMED IN
PROPOSAL, IF APPROVED BY OWNER.
ARTICLE 24 - SCOPE OF AGREEMENT
EXECUTION OF ABOVE MENTIONED OWNER-CONTRACTOR AGREEMENT, BOTH
OWNER AND CONTRACTOR AGREE TO BE BOUND BY EACH AND EVERY TERM
AND CONDITION OF AFORESAID CONTRACT DOCUMENTS.
ARTICLE 25 - MECHANICAL EQUIPMENT MANUALS
CONTRACTOR DELIVER TO OWNER WITHIN ONE WEEK OF COMPLETION OF
CONTRACTOR SEND WRITTEN NOTICES INDICATING NATURE AND SCOPE OF
WORK TO ALL PROPERTY OWNERS IN VICINITY OF WORK WHOSE PROPERTY
MIGHT IN ANYWAY BE AFFECTED BY WORK UNDER THIS CONTRACT.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
ARTICLE 27 - SUBCONTRACTORS
LIST OF SUBCONTRACTORS REFERRED TO UNDER ARTICLE 5.2.1 OF GENERAL
CONDITIONS OF CONTRACT SHALL INCLUDE EACH SUBCONTRACTOR'S
ADDRESS AND TELEPHONE NUMBER.
A
R
4 0 4 S.
ARTICLE 28 - INSURANCE REQUIREMENT
IN ADDITION TO THOSE CALLED FOR IN GENERAL CONDITIONS
A) GENERAL: THESE REQUIREMENTS ARE INCLUDED IN THE BID DOCUMENTS.
ARTICLE 29 - INSPECTING AND TESTING LABORATORY SERVICES
A) OWNER WILL APPOINT, EMPLOY, AND PAY FOR SPECIFIED SERVICES OF AN
INDEPENDENT FIRM TO PERFORM INSPECTING AND TESTING THAT IS SPECIFIED
AS OWNER'S RESPONSIBILITIES. THE CONTRACTOR WILL APPOINT, EMPLOY
AND PAY FOR SPECIFIED SERVICES OF AN INDEPENDENT FIRM TO PERFORM
INSPECTION AND TESTING THAT IS SPECIFIED AS CONTRACTOR'S
RESPONSIBILITY.
B) THE INDEPENDENT FIRM WILL PERFORM INSPECTIONS, TESTS, AND OTHER
SERVICES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS AND AS
REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER.
C) INSPECTING, TESTING, AND SOURCE QUALITY CONTROL MAY OCCUR ON OR
OFF THE PROJECT SITE. PERFORM OFF-SITE INSPECTING OR TESTING AS
REQUIRED BY THE ARCHITECT/ENGINEER OR THE OWNER.
D) REPORTS WILL BE SUBMITTED BY THE INDEPENDENT FIRM TO THE
ARCHITECT/ENGINEER,IN DUPLICATE, INDICATING OBSERVATIONS AND
RESULTS OF TESTS AND INDICATING COMPLIANCE OR NONCOMPLIANCE WITH
CONTRACT DOCUMENTS. WRITTEN INSPECTION TEST REPORTS SHALL
INCLUDE:
1. TEST AGENCY NAME
2. DATES AND LOCATIONS OF SAMPLES, TESTS, OR INSPECTIONS.
3. NAME OF INDIVIDUALS PRESENT.
4. COMPLETE INSPECTION OR TEST DATA.
5. TEST RESULTS AND INTERPRETATIONS.
6. RECOMMENDATIONS.
E) COOPERATE WITH INDEPENDENT FIRM; FURNISH SAMPLES OF MATERIALS,
DESIGN MIX, EQUIPMENT, TOOLS, STORAGE, SAFE ACCESS, AND ASSISTANCE
BY INCIDENTAL LABOR AS REQUESTED.
1. NOTIFY ARCHITECT/ENGINEER AND INDEPENDENT FIRM FORTY EIGHT
(48) HOURS PRIOR TO EXPECTED TIME FOR OPERATIONS REQUIRING
SERVICES.
2. MAKE ARRANGEMENTS WITH INDEPENDENT FIRM AND PAY FOR
ADDITIONAL SAMPLES AND TESTS REQUIRED FOR CONTRACTOR'S USE.
F) TESTING OR INSPECTING DOES NOT RELIEVE CONTRACTOR TO PERFORM
WORK TO CONTRACT REQUIREMENTS.
G) RETESTING REQUIRED BECAUSE OF NON-CONFORMANCE TO SPECIFIED
REQUIREMENTS SHALL BE PERFORMED BY THE SAME INDEPENDENT FIRM ON
INSTRUCTIONS BY THE ARCHITECT/ENGINEER. PAYMENT FOR RETESTING WILL
BE CHARGED TO THE CONTRACTOR BY DEDUCTING INSPECTING OR TESTING
CHARGES FROM THE CONTRACT SUM/PRICE.
ARTICLE 30 - SUBSTITUTIONS
A) ARCHITECT/ENGINEER WILL CONSIDER REQUESTS FOR SUBSTITUTIONS
ONLY WITHIN FIFTEEN DAYS AFTER DATE ESTABLISHED IN NOTICE TO
PROCEED.
B) SUBSTITUTIONS MAY BE CONSIDERED WHEN A PRODUCT BECOMES
UNAVAILABLE THROUGH NO FAULT OF THE CONTRACTOR.
C) DOCUMENT EACH REQUEST WITH COMPLETE DATA SUBSTANTIATING
COMPLIANCE OF PROPOSED SUBSTITUTION WITH CONTRACT DOCUMENTS.
D) A REQUEST CONSTITUTES A REPRESENTATION THAT THE CONTRACTOR:
1. HAS INVESTIGATED PROPOSED PRODUCT AND DETERMINED THAT IT
MEETS OR EXCEEDS THE QUALITY LEVEL OF THE SPECIFIED PRODUCT.
2. WILL PROVIDE THE SAME WARRANTY FOR THE SUBSTITUTION AS FOR THE
SPECIFIED PRODUCT.
3. WILL COORDINATE INSTALLATION AND MAKE CHANGES TO OTHER WORK
WHICH MAY BE REQUIRED FOR THE WORK TO BE COMPLETE WITH NO
ADDITIONAL COST TO OWNER. WHICH MAY SUBSEQUENTLY BECOME
APPARENT.
4. WAIVES CLAIMS FOR ADDITIONAL COSTS OR TIME EXTENSION
5. WILL REIMBURSE OWNER FOR REVIEW OR REDESIGN SERVICES
ASSOCIATED WITH PRE-APPROVAL BY AUTHORITIES.
E) SUBSTITUTIONS WILL NOT BE CONSIDERED WHEN THEY ARE INDICATED OR
IMPLIED ON SHOP DRAWING OR PRODUCT DATA SUBMITTALS, WITHOUT
SEPARATE WRITTEN REQUEST, OR WHEN ACCEPTANCE WILL REQUIRE
REVISION TO THE CONTRACT DOCUMENTS.
F) SUBSTITUTION SUBMITTAL PROCEDURE:
1. SUBMIT THREE COPIES OF REQUEST FOR SUBSTITUTION FOR
CONSIDERATION. LIMIT EACH REQUEST TO ONE PROPOSED SUBSTITUTION.
2. SUBMIT SHOP DRAWINGS, PRODUCT DATA, AND CERTIFIED TEST RESULTS
ATTESTING TO THE PROPOSED PRODUCT EQUIVALENCE. BURDEN OF PROOF
IS ON PROPOSER.
3. THE ARCHITECT/ENGINEER WILL NOTIFY CONTRACTOR IN WRITING OF
DECISION TO ACCEPT OR REJECT REQUEST.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
ARTICLE 31 - CLOSEOUT PROCEDURES
A) SUBMIT WRITTEN CERTIFICATION THAT CONTRACT DOCUMENTS HAVE BEEN
REVIEWED, WORK HAS BEEN INSPECTED, AND THAT WORK IS COMPLETE IN
ACCORDANCE WITH CONTRACT DOCUMENTS AND READY FOR OWNER'S
REVIEW.
B) PROVIDE SUBMITTALS TO ARCHITECT/ENGINEER THAT ARE REQUIRED BY
GOVERNING OR OTHER AUTHORITIES.
C) SUBMIT FINAL APPLICATION FOR PAYMENT IDENTIFYING TOTAL ADJUSTED
CONTRACT SUM, PREVIOUS PAYMENTS, AND SUM REMAINING DUE.
S
0334
PROJECT NUMBER: 16-059
IS NOT OBLIGATED FOR COST INCURRED BY BIDDER IN PREPARING BID. OWNER IS
NOT OBLIGATED TO ACCEPT LOWEST BID, OR ANY BID.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
SPECIFICATIONS
SHEET TITLE
ARCHITECTURAL
SPECIFICATIONS
SHEET NUMBER
AS1.0
F.
ARTICLE 33 - PROJECT RECORD DOCUMENTS
A) MAINTAIN ON SITE, ONE SET OF THE FOLLOWING RECORD DOCUMENTS;
RECORD ACTUAL REVISIONS TO THE WORK:
1. DRAWINGS.
2. SPECIFICATIONS.
3. ADDENDA.
4. CHANGE ORDERS AND OTHER MODIFICATIONS TO THE CONTRACT.
5. REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
6. MANUFACTURER'S INSTRUCTION FOR ASSEMBLY, INSTALLATION, AND
ADJUSTING.
B) ENSURE ENTRIES ARE COMPLETE AND ACCURATE, ENABLING FUTURE
REFERENCE BY OWNER.
C) STORE RECORD DOCUMENTS SEPARATE FROM DOCUMENTS USED FOR
CONSTRUCTION.
D) RECORD INFORMATION CONCURRENT WITH CONSTRUCTION PROGRESS.
E) SPECIFICATIONS: LEGIBLY MARK AND RECORD AT EACH PRODUCT
DESCRIPTION OF ACTUAL PRODUCTS INSTALLED, INCLUDING THE FOLLOWING:
1. MANUFACTURER'S NAME AND PRODUCT MODEL AND NUMBER.
2. PRODUCT SUBSTITUTIONS OR ALTERNATES UTILIZED.
3. CHANGES MADE BY ADDENDA AND MODIFICATIONS.
F) RECORD DOCUMENTS AND SHOP DRAWINGS: LEGIBLY MARK EACH ITEM TO
RECORD ACTUAL CONSTRUCTION INCLUDING:
1. MEASURED HORIZONTAL AND VERTICAL LOCATIONS OF UNDERGROUND
UTILITIES AND APPURTENANCES, REFERENCED TO PERMANENT SURFACE
IMPROVEMENTS.
2. MEASURED LOCATIONS OF INTERNAL UTILITIES AND APPURTENANCES
CONCEALED IN CONSTRUCTION, REFERENCED TO VISIBLE AND ACCESSIBLE
FEATURES OF THE WORK.
3. FIELD CHANGES OF DIMENSION AND DETAIL.
4. DETAILS NOT ON ORIGINAL CONTRACT DRAWINGS.
G) REMOVE ARCHITECT/ENGINEER TITLE BLOCK AND SEAL FROM ALL
DOCUMENTS.
H) FOLLOW CLOSE OUT PROCEDURE FROM PRE-CONSTRUCTION MEETING.
G.
H.
ARTICLE 34 - OPERATION AND MAINTENANCE DATA
A) FOR EACH PIECE OF OPERATING EQUIPMENT FURNISHED UNDER THIS
CONTRACT, SUBMIT TO THE OWNER CONSOLIDATED OPERATION AND
MAINTENANCE DATA INCLUDING THE FOLLOWING.
1. PURCHASE, INSTALLATION, BALANCING, AND ADJUSTMENT RECORDS, AS
APPLICABLE.
2. MANUFACTURER'S INSTRUCTIONS FOR OPERATION, MAINTENANCE,
DIAGNOSTICS, AND ADJUSTMENT PROCEDURES, AS APPROPRIATE.
3. CONTACT INFORMATION FOR SERVICE.
4. WARRANTY.
B) WAIVER OF THESE O&M DATA SUBMITTAL REQUIREMENTS ARE SUBJECT TO
APPROVAL BY THE OWNER'S REPRESENTATIVE..
I.
ARTICLE 35 - WARRANTIES
A) EXECUTE AND ASSEMBLE TRANSFERABLE WARRANTY DOCUMENTS FROM
SUBCONTRACTORS, SUPPLIERS, AND MANUFACTURERS.
B) FOR ITEMS OF WORK DELAYED BEYOND DATE OF SUBSTANTIAL
COMPLETION, PROVIDE UPDATED SUBMITTAL WITHIN FIFTEEN DAYS AFTER
ACCEPTANCE, LISTING DATE OF ACCEPTANCE AS START OF WARRANTY
PERIOD.
C) SUBMIT PRIOR TO FINAL APPLICATION FOR PAYMENT.
J.
ARTICLE 36 - SPARE PARTS AND MAINTENANCE MATERIALS
A) PROVIDE PRODUCTS, SPARE PARTS, MAINTENANCE AND EXTRA MATERIALS
IN QUANTITIES SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS.
B) DELIVER TO PROJECT SITE AND PLACE IN LOCATION AS DIRECTED; OBTAIN
RECEIPT PRIOR TO FINAL PAYMENT.
GENERAL SPECIFICATIONS
K.
DIVISION 01 - GENERAL REQUIREMENTS
013300 - SUBMITTAL PROCEDURES
1.
GENERAL
A. SUMMARY: SECTION INCLUDES
1) SUBMITTAL FORM REQUIREMENTS
2) SUBMITTAL SCHEDULE
3) CONTRACTOR RESPONSIBILITIES
4) REQUIREMENTS FOR EACH TYPE OF SUBMITTAL
B. SUBMITTAL FORM REQUIREMENTS: PROVIDE THE FOLLOWING, AS
APPLICABLE ON EACH SUBMITTAL:
1) PRESENT AND PREVIOUS SUBMITTAL DATES.
2) THE PROJECT TITLE AND NUMBER.
3) CONTRACTOR'S SUBMITTAL NUMBER.
4) SUBCONTRACT IDENTIFICATION.
5) THE NAMES OF:
A) CONTRACTOR.
B) SUPPLIER.
C) MANUFACTURER.
6) IDENTIFICATION OF REVISIONS ON RESUBMITTALS.
7) FOR EACH PRODUCT, REFERENCE CORRESPONDING SPECIFICATION
AND PARAGRAPH NUMBER.
8) A 6 X 4 INCH BLANK SPACE FOR STAMPS.
C. DELIVER SUBMITTALS TO THE OWNER'S REPRESENTATIVE. INCLUDE NAME
OF CONTACT PERSON IDENTIFIED AT THE TIME OF AGREEMENT.
D. SUBMITTALS IN GRAPHIC FORM SHALL BE CLEAR READABLE COPIES WITH
CONTRACTOR'S ORIGINAL STAMP.
E. SUBMITTAL SCHEDULE
1) MAKE SUBMITTALS AS REQUIRED TO CAUSE NO DELAY IN THE WORK.
2) REQUIRE EACH SUBCONTRACTOR TO MAKE SUBMITTALS WITHIN 60
DAYS OF THE SUBCONTRACT DATE, UNLESS SPECIFIED OR APPROVED
OTHERWISE, OR REQUIRED TO MEET THE WORK SCHEDULE.
3) SCHEDULE SUBMITTALS TO ALLOW SUFFICIENT TIME FOR POSSIBLE
REVISION AND RESUBMITTAL OF THE REJECTED SUBMITTALS, WITHOUT
AFFECTING THE CONSTRUCTION SCHEDULE.
4) MAKE THE FOLLOWING SUBMITTALS PRIOR TO STARTING
CONSTRUCTION :
A) CERTIFICATES OF INSURANCE.
CONTAINERS OR PACKAGING, STORED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS, UNTIL READY FOR INSTALLATION.
3) PRODUCTS INDICATED OR SCHEDULED AS VENDOR-FURNISHED WILL BE
PAID FOR BY THE OWNER AND DELIVERED TO THE SITE. COORDINATE
WITH THE OWNER.
4) PRODUCTS AND MATERIALS DAMAGED AFTER ACCEPTANCE OF
DELIVERY SHALL BE REPLACED WITH NEW LIKE PRODUCTS, AT NO
ADDITIONAL COST TO THE OWNER.
B. GENERAL INSTALLATION REQUIREMENTS
1) ENVIRONMENTAL REQUIREMENTS: MAINTAIN TEMPERATURE RANGES,
HUMIDITY, AND PROTECTION PROVISIONS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
2) EXAMINATION
A) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER
TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT
WHERE WORK MAY PROPERLY COMMENCE.
B) REQUIRE CORRECTION OF CONDITIONS DETRIMENTAL TO PROPER
AND TIMELY COMPLETION OF THE WORK.
C) BEGINNING WORK CONSTITUTES ACCEPTANCE OF SITE CONDITIONS
AND RESPONSIBILITY FOR DEFECTIVE INSTALLATION CAUSED BY
PRIOR OBSERVABLE CONDITIONS.
3) UNLESS INDICATED OR SPECIFIED OTHERWISE, INSTALL EACH
PRODUCT IN ACCORDANCE WITH THE PRODUCT MANUFACTURER'S
INSTRUCTIONS.
4) MAINTAIN ONE SET OF COMPLETE INSTRUCTIONS AT THE JOB SITE
DURING INSTALLATION AND UNTIL COMPLETION.
C. PRODUCT OPTIONS
1) PRODUCT SPECIFIED BY REFERENCE STANDARDS OR BY DESCRIPTION
ONLY: PROVIDE PRODUCT MEETING THOSE STANDARDS.
2) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS WITH
AN "OR APPROVED" PROVISION: USE SPECIFIED PRODUCT OR SUBMIT A
REQUEST FOR SUBSTITUTION IN ACCORDANCE WITH THE SPECIFIED
SUBSTITUTION REQUIREMENTS. WHEN APPROVED A SUBSTITUTE
PRODUCT MAY BE USED.
3) PRODUCT SPECIFIED BY NAMING ONE OR MORE MANUFACTURERS,
WITHOUT A PROVISIONS FOR SUBSTITUTION: NO SUBSTITUTION WILL BE
ALLOWED, EXCEPT AS SPECIFIED UNDER THE ARTICLE ON
SUBSTITUTIONS.
D. SUBSTITUTIONS: IN ACCORDANCE WITH THE GENERAL AND
SUPPLEMENTARY CONDITIONS, AND AS FOLLOWS.
1) FURNISH PRODUCTS SPECIFIED, EXCEPT WHERE "OR APPROVED" IS
USED; SUBSTITUTE PRODUCTS MAY BE SUBMITTED TO ARCHITECT FOR
APPROVAL.
2) SUBSTITUTIONS WILL BE CONSIDERED ONLY FOR THE FOLLOWING
REASONS:
A) A PRODUCT BECOMES UNAVAILABLE DUE TO NO FAULT OF THE
CONTRACTOR.
B) A SUBSTITUTE PRODUCT WILL BE IN OWNER'S BEST INTEREST BY
PROVIDING A COST SAVINGS, PRODUCT QUALITY OR UTILITY
ADVANTAGE, OR SCHEDULE BENEFIT.
3) DOCUMENT EACH SUBSTITUTION REQUEST WITH COMPLETE DATA
SUBSTANTIATING COMPLIANCE OF PROPOSED SUBSTITUTION WITH
CONTRACT DOCUMENTS.
4) A SUBSTITUTION REQUEST CONSTITUTES A REPRESENTATION THAT
CONTRACTOR:
A) HAS INVESTIGATED PROPOSED PRODUCT AND HAS DETERMINED
THAT IT MEETS OR EXCEEDS PERFORMANCE OF THE SPECIFIED
PRODUCT, IN ALL RESPECTS.
B) SHALL PROVIDE THE SAME WARRANTY FOR SUBSTITUTION AS FOR
SPECIFIED PRODUCT.
C) WILL COORDINATE INSTALLATION AND MAKE OTHER CHANGES
WHICH MAY BE REQUIRED FOR WORK TO BE COMPLETE IN ALL
RESPECTS.
D) WAIVES CLAIMS FOR ADDITIONAL COSTS THAT MAY SUBSEQUENTLY
BECOME APPARENT.
E) AGREES TO PAY ALL COSTS OF REDESIGN RELATED TO THE
SUBSTITUTION.
5) UNLESS PREVIOUSLY APPROVED, SUBSTITUTIONS IMPLIED ON SHOP
DRAWINGS WILL NOT BE ACCEPTED.
6) THE ARCHITECT WILL DETERMINE ACCEPTABILITY OF PROPOSED
SUBSTITUTION, COORDINATE WITH THE OWNER, AND WILL NOTIFY
CONTRACTOR OF ACCEPTANCE OR REJECTION WITHIN A REASONABLE
TIME.
C)
018113 - SUSTAINABLE DESIGN REQUIREMENTS
B.
C.
D.
E.
TEMPORARY HEATING: PROVIDE TEMPORARY HEAT TO PROTECT WORK
AND MATERIALS AGAINST INJURY FROM DAMPNESS AND COLD AND TO
DRY OUT BUILDING. FUEL, EQUIPMENT, AND METHOD OF HEATING
SATISFACTORY TO ARCHITECT. MINIMUM TEMPERATURE FOR WORK 50
DEGREES FAHRENHEIT.
TEMPORARY UTILITIES: ARRANGE FOR AND FURNISH WATER, GAS AND
ELECTRICITY TO DATE OF OCCUPANCY BY OWNER. FURNISH ELECTRICITY
FOR LIGHT AND POWER DURING CONSTRUCTION PERIOD INCLUDING
LAMPS. OTHER CONTRACTORS USING TEMPORARY SERVICES SHALL PAY
FOR ALL DAMAGES TO LIFE, LIMB OR PROPERTY WHICH RESULT FROM
THEIR USE OF TEMPORARY SERVICES.
SANITARY CONVENIENCES: PROVIDE SANITARY CONVENIENCES REQUIRED
FOR WORKMEN AND MAINTAIN SAME IN SANITARY CONDITION.
TEMPORARY TELEPHONE AND FAX SERVICE: PROVIDE JOB TELEPHONE,
LISTED WITH TELEPHONE COMPANY UNDER THE NAME OF THE GENERAL
CONTRACTOR. TELEPHONE, PORTABLE TELEPHONE AND FAX MACHINE TO
BE INSTALLED IMMEDIATELY UPON START OF CONSTRUCTION AND
MAINTAINED FOR THE DURATION OF CONSTRUCTION. POTBELLY SANDWICH
WORKS WILL ARRANGE FOR INSTALLATION OF PERMANENT SERVICE AT
THE TIME OF OCCUPATION OF BUILDING. PHONE TO HAVE OUTSIDE BELL
OR BUZZER.
PROVIDE AND MAINTAIN ALL NECESSARY TEMPORARY STAIRS, LADDERS,
RAMPS, PLATFORMS, HOISTS, ETC., AS REQUIRED FOR PROPER EXECUTION
OF THE WORK, ALL OF WHICH SHALL COMPLY WITH THE REQUIREMENTS OF
ALL APPLICABLE STATE AND LOCAL CODES.
016000 - PRODUCT REQUIREMENTS
A.
DELIVERY, STORAGE, AND HANDLING:
1) TRANSPORT AND HANDLE PRODUCTS BY METHODS TO AVOID PRODUCT
DAMAGE.
2) MANUFACTURED PRODUCTS SHALL REMAIN IN MANUFACTURER'S
WATER EFFICIENCY
A) WE CREDIT 2 - WATER USE REDUCTION: WATER USING APPLIANCES
AND FIXTURES SHALL EXCEED BASELINE LEVELS BY A MINIMUM
ENERGY AND ATMOSPHERE
A) EA PREREQUISITE 1 - FUNDAMENTAL COMMISSIONING OF BUILDING
ENERGY SYSTEMS: COORDINATE WITH OWNER FOR STARTUP AND
COMMISSIONING OF HVAC
B) EA PREREQUISITE 3 - FUNDAMENTAL REFRIGERANT MANAGEMENT:
VERIFY REFRIGERANT TYPE.
4) MATERIALS AND RESOURCES
A) MR CREDIT 2 - CONSTRUCTION WASTE MANAGEMENT: SUBMIT AS
REQUIRED TO DOCUMENT SORTING, QUANTITIES, AND DISPOSITION
AND DIVERSION OF CONSTRUCTION WASTE INCLUDING
(1) CONCRETE
(2) WOOD
(3) GYPSUM
(4) CARDBOARD
(5) PLASTIC
(6) MIXED WASTE
B) MR CREDIT 4 - RECYCLED CONTENT: MINIMUM 10 PERCENT
INCORPORATED RECYCLED CONTENT, BASED ON COST AND
DETERMINED BY SUM OF POST-CONSUMER PLUS
1.
MR CREDIT 5 - REGIONAL MATERIALS: MINIMUM 20 PERCENT OF
MATERIALS AND PRODUCTS, BASED ON COST OF COMPONENTS AND
CONTENT EXTRACTED, HARVESTED, RECOVERED, OR
MANUFACTURED WITHIN 500 MILES OF THE PROJECT SITE.
D) MR CREDIT 7 - CERTIFIED WOOD: MINIMUM 50 PERCENT, BASED ON
RELATIVE COST OF INCORPORATED CONTENT, WOOD AND WOOD
PRODUCTS CERTIFIED BY THE FOREST STEWARDSHIP COUNCIL
5) INDOOR ENVIRONMENTAL QUALITY.
A) IEQ CREDIT 3.1; 3.2 - CONSTRUCTION IAQ MANAGEMENT PLAN:
DEVELOP AND IMPLEMENT AN IAQ MANAGEMENT PLAN FOR
CONSTRUCTION AND PRE-OCCUPANCY PHASES OF THE BUILDING.
(1) MEET OR EXCEED RECOMMENDED CONTROL MEASURES OF
SMACNA IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER
CONSTRUCTION, 2ND EDITION 2007.
(2) PROTECT ONSITE AND INSTALLED ABSORPTIVE MATERIALS
FROM MOISTURE.
(3) FOR HVAC EMPLOYED DURING CONSTRUCTION, USE MINIMUM
MERV 8 FILTRATION. REPLACE FILTRATION MEDIA
IMMEDIATELY PRIOR TO PROJECT TURNOVER.
(4) AFTER CONSTRUCTION ENDS AND PRIOR TO OCCUPANCY,
PERFORM PROJECT AREA FLUSH-OUT BY SUPPLYING A TOTAL
AIR VOLUME OF 14,000 CF OF OUTDOOR AIR PER SF OF
PROJECT FLOOR AREA.
B) IEQ CREDIT 4 - LOW EMITTING MATERIALS.
(1) CREDIT 4.1 - ADHESIVES AND SEALANTS: LIMIT VOC CONTENT
OF EACH RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE
1168, AMENDED JANUARY 7, 2005; LIMIT AEROSOL ADHESIVES
IN ACCORDANCE WITH GREEN SEAL GS-36, EFFECTIVE
OCTOBER 19, 2000.
(2) CREDIT 4.2 - PAINTS AND COATINGS: LIMIT VOC CONTENT OF
EACH RAW MATERIAL IN ACCORDANCE WITH GREEN SEAL
GS-11, EFFECTIVE MAY 20, 1993; LIMIT ANTI-CORROSIVE AND
PRODUCTS - NOT USED
3.
EXECUTION
A. GENERAL
1) CORRECTION OF WORK NOT CONFORMING WITH SPECIFIED
SUSTAINABILITY REQUIREMENTS SHALL BE PERFORMED AT
CONTRACTOR'S EXPENSE.
2) SUSTAINABILITY INTRODUCTION MEETING: ADDRESS AS A SEPARATE
AGENDA ITEM AN ORIENTATION SESSION TO FAMILIARIZE
CONSTRUCTION FORCES WITH SUSTAINABILITY INTENT.
B. SUSTAINABILITY OBJECTIVES
1) INTENT
A) PERFORM WORK TO QUALIFY FOR THE FOLLOWING LEED-NC
EQUIVALENT PREREQUISITES AND CREDITS. UNLESS OTHERWISE
INDICATED, WHERE CONTRACTOR- AND OWNER-FURNISHED
MATERIALS AND EQUIPMENT ARE CONTRIBUTORY, DOCUMENT TO
INDICATE AGGREGATE CONTRIBUTIONS TO ACHIEVE CREDITS AT
THE LEVELS INDICATED. COMPLY WITH REFERENCED DOCUMENTS
FOR SPECIFIC REQUIREMENTS.
B) WHERE TARGET PERCENTAGES ARE INDICATED, MEET OR EXCEED
THOSE REQUIREMENTS TO THE GREATEST REASONABLE EXTENT.
3.
(3)
(4)
(5)
FLOOR COATINGS, STAINS, PRIMERS AND SHELLACS IN
ACCORDANCE WITH SCAQMD RULE 1113, EFFECTIVE JANUARY
1, 2004.
CREDIT 4.3 - FLOORING SYSTEMS:
(a) RESILIENT FLOORING AND BASE; CERAMIC TILE
FLOORING: CERTIFIED AS COMPLIANT WITH CALIFORNIA
DEPARTMENT OF HEALTH SERVICES (FLOOR SCORE).
(b) TILE SETTING ADHESIVES: LIMIT VOC CONTENT OF EACH
RAW MATERIAL IN ACCORDANCE WITH SCAQMD RULE
1168, AMENDED JANUARY 7, 2005.
CREDIT 4.4 - COMPOSITE WOOD AND AGRIFIBER PRODUCTS:
VERIFY FREEDOM FROM ADDED UREA_FORMALDEHYDE.
CREDIT 4.6 - CEILING AND WALL SYSTEMS: VERIFY
COMPLIANCE WITH CALIFORNIA DHS STANDARD PRACTICE FOR
TESTING OF VOLATILE ORGANIC EMISSIONS, INCLUDING 2004
ADDENDA.
DIVISION 02 - EXISTING CONDITIONS
A.
B.
C.
D.
E.
F.
DEMOLISH IN AN ORDERLY AND CAREFUL MANNER AS REQUIRED TO
ACCOMMODATE THE WORK. WHERE DEMOLITION EXCEEDS THAT
INDICATED, VERIFY SUCH DEMOLITION WITH THE ARCHITECT AND THE
LANDLORD PRIOR TO PROCEEDING.
NOTIFY THE LANDLORD PRIOR TO CUTTING OR FASTENING INTO
CONCRETE SLABS. X-RAY AS DIRECTED AND AS NECESSARY TO
DETERMINE LOCATION OF TENDONS, REINFORCING, OR UTILITIES.
NOTIFY THE OWNER PRIOR TO COMMENCING DEMOLITION WORK,
COORDINATE WITH OWNER FOR REMOVAL OF ITEMS TO BE CLAIMED.
EXCEPT WHERE NOTED OR SPECIFIED OTHERWISE, TAKE POSSESSION OF
MATERIALS BEING DEMOLISHED, AND IMMEDIATELY REMOVE FROM SITE.
DO NOT OVERLOAD EXISTING CONSTRUCTION TO REMAIN WITH
DEMOLISHED MATERIALS.
PROVIDE A SMOOTH, EVEN, AND INVISIBLE TRANSITION TO NEW
CONSTRUCTION. WHEN FINISHED SURFACES ARE CUT SO THAT AN
INVISIBLE TRANSITION WITH NEW WORK IS NOT POSSIBLE, TERMINATE
EXISTING SURFACE ALONG THE NEAREST BREAK LINE, JOINT, OR CORNER.
WHERE SLAB PENETRATIONS ARE INDICATED OR REQUIRED, X-RAY THE
SLAB PRIOR TO CUTTING. NOTIFY THE ARCHITECT FOR RESOLUTION
WHERE TENDONS, REINFORCING, OR EMBEDDED UTILITIES ARE
DISCOVERED.
REPAIR DEMOLITION PERFORMED IN EXCESS OF THAT REQUIRED, AT NO
ADDITIONAL COST TO THE OWNER.
DIVISION 03 - CONCRETE
030133 - CAST-IN-PLACE CONCRETE
1.
2.
GENERAL
A. SECTION INCLUDES:
1) CONCRETE SLAB INFILL AND CURBS.
2) TRENCHING AND PIPE BEDDING.
3) CAST-IN-PLACE CONCRETE FOR INFILL OF TRENCHES.
PRODUCTS
A. PLYWOOD: APA MEDIUM DENSITY OR HIGH DENSITY OVERLAY, PLYFORM
REINFORCING: AS INDICATED ON THE DRAWINGS.
C. CONCRETE MATERIALS:
1) CEMENT: ASTM C150, NORMAL - TYPE 1 PORTLAND CEMENT.
2) NORMAL WEIGHT FINE AND COARSE AGGREGATES: ASTM C33.
3) WATER: CLEAN AND NOT DETRIMENTAL TO CONCRETE.
4) ADMIXTURES
B.
054000 - COLD FORMED METAL FRAMING
1.
EXECUTION
A. TRENCHING
1) COORDINATE WITH DIVISION 02, PLUMBING, AND MECHANICALWORK AS
APPROPRIATE
A) MAKE TRENCHES WITH SUFFICIENT WIDTH TO PERMIT
INSTALLATION.
B) WHERE WATERPROOF MEMBRANE IS INDICATED OR REQUIRED,
REPAIR DAMAGE TO EXISTING MEMBRANE AS NECESSARY TO
MAINTAIN BARRIER BETWEEN NEW CONSTRUCTION AND OCCUPIED
SPACE BELOW.
B. PLACEMENT
1) MIX CONCRETE IN ACCORDANCE WITH ASTM C94; MINIMUM 3000 PSI,
PLACEMENT AND FINISHING:
A) USE BONDING AGENT AT INTERFACE WITH EXISTING SLAB EDGE
B) PLACE REINFORCING AND CONCRETE IN ACCORDANCE WITH ACI
301.
C) FINISH CONCRETE SLABS LEVEL AS INDICATED ON THE DRAWINGS.
D) FULL TROWEL FINISH INTERIOR FLOOR SLAB SURFACES TO MATCH
ADJACENT WORK.
C. CURING: MOISTURE CURE ALL CONCRETE FOR A MINIMUM OF 7 DAYS.
C)
GENERAL
A. SUMMARY
1) WHERE PRACTICAL, THIS PROJECT WILL VOLUNTARILY COMPLY WITH
USGBC REQUIREMENTS FOR SUSTAINABLE DESIGN AND
CONSTRUCTION FOR NEW CONSTRUCTION AS SPECIFIED.
2) EXCEPT AS OTHERWISE INDICATED, WHERE SUBMITTALS ARE
REQUIRED TO DOCUMENT COMPLIANCE WITH DESIGN INTENT,
SUBMITTALS FOR VERIFICATION OF ITEMS SUCH AS SUSTAINABLE SITES
REQUIREMENTS, WATER EFFICIENCY, ENERGY PERFORMANCE,
THERMAL COMFORT, AND FACILITY OPERATION ARE OUTSIDE THE
SCOPE OF THIS CONTRACT.
B. REFERENCES
1) LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION,
2009 EDITION.
2) LEED REFERENCE GUIDE FOR BUILDING DESIGN AND CONSTRUCTION RETAIL SUPPLEMENT, 2009 EDITION.
C. REQUIREMENTS
1) MAKE SUBMITTALS AS SPECIFIED, AS REQUESTED, AND NECESSARY TO
SUPPORT SPECIFIC SUSTAINABILITY REQUIREMENTS.
2) TRACK MATERIALS AND PROCEDURES AS NECESSARY TO VERIFY
ACHIEVEMENT OF OBJECTIVES.
3) COORDINATE THE WORK TO INTEGRATE THE WORK AMONG
REQUIREMENTS FOR AIR QUALITY MANAGEMENT, CONSTRUCTION
WASTE MANAGEMENT, AND COMMISSIONING.
2.
WATER REDUCER NORMAL: ASTM C494, TYPE A.
ACCELERATOR: ASTM C494, TYPE C OR E, NON-CORROSIVE,
NON-CHLORIDE.
D. ACCESSORIES:
1) BONDING AGENT: 2-COMPONENT MOISTURE INSENSITIVE, 100 PERCENT
SOLIDS EPOXY ADHESIVE WITH SHEAR BOND TO CONCRETE STRENGTH
>1400 PSI.
2) CURING MATERIALS: WATERPROOF SHEET: ASTM C171; MINIMUM 4 MIL
POLYETHYLENE SHEET OR REINFORCED WATERPROOF KRAFT PAPER.
3) WATERPROOF MEMBRANE: MATCH EXISTING, UNLESS APPROVED
OTHERWISE..
A)
B)
3)
024119 - SELECTIVE DEMOLITION
015000 - TEMPORARY FACILITIES
A.
2)
2)
035416 - HYDRAULIC CEMENT UNDERLAYMENT AND TOPPING
1.
GENERAL
A. SECTION INCLUDES: LEVELING OF EXISTING CAST-IN-PLACE CONCRETE
SLABS.
2.
PRODUCTS
A. SELF LEVELING TOPPING SYSTEM: POURABLE, CEMENT BASED MATERIAL,
TRAFFIC BEARING TYPE; MINIMUM 28 DAY COMPRESSIVE STRENGTH 6,000
PSI; MINIMUM BOND STRENGTH 200 PSI.
1) BASIS OF DESIGN: MAPEI AMERICAS "ULTRATOP"; GRAY COLOR.
2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT
DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF
CONFORMANCE TO DESIGN INTENT.):
A) ARDEX INC. "SD-T" SELF-LEVELING SELF-DRYING CONCRETE
TOPPING.
B) PROSPEC "LEVEL SET WEAR TOPPING."
B. SELF LEVELING UNDERLAYMENT SYSTEM: POURABLE, CEMENT BASED
MATERIAL, MINIMUM 28 DAY COMPRESSIVE STRENGTH 3,000 PSI; MINIMUM
BOND STRENGTH 200 PSI.
1) BASIS OF DESIGN: MAPEI AMERICAS "ULTRAPLAN 1 PLUS".
2) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT
DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF
CONFORMANCE TO DESIGN INTENT.):
A) ARDEX INC. "K-15" SELF-LEVELING UNDERLAYMENT CONCRETE.
B) KOESTER AMERICAN CORPORATION "VAP-1 LEVEL PRO."
C) SUPERCAP (HASLET TX; 866_704_2247) "SUPERCAP SELF-LEVELING
UNDERLAYMENT."
D) PROSPEC "LEVEL SET 300."
E) LATICRETE INTERNATIONAL, INC. "LATICRETE 86 LATILEVEL THIN
POUR UNDERLAYMENT."
C. REPAIR MORTAR: MAPEI AMERICAS "PLANITOP X," OR APPROVED.
D. ACCESSORIES: FURNISH PRIMERS, PATCHING COMPOUNDS, AND SAND
FILLERS AS NECESSARY FOR TROWELABLE APPLICATIONS AND AS
RECOMMENDED BY THE UNDERLAYMENT MANUFACTURER FOR THE
CONDITIONS OF THE PROJECT.
3.
EXECUTION
A. GENERAL:
1) SURFACES SCHEDULED FOR SEALED CONCRETE: INSTALL
CEMENTITIOUS TOPPING TO CONCRETE SLABS AS INDICATED ON THE
DRAWINGS, AND AS NECESSARY TO LEVEL SLABS OR BRING
SUBSTRATES TO PROPER ELEVATION.
2) SURFACES TO RECEIVE SUBSEQUENT ADHERED FINISHES: WITH THE
EXCEPTION OF AREAS WHERE LEVELING CAN BE ACCOMPLISHED BY
USE OF LATEX UNDERLAYMENT, AS SPECIFIED IN SECTION 096519,
INSTALL CEMENTITIOUS UNDERLAYMENT TO CONCRETE SLABS AS
INDICATED ON THE DRAWINGS OR AS DETERMINED BY THE OWNER'S
REPRESENTATIVE DURING FIELD VISIT, AND AS NECESSARY TO LEVEL
SLABS OR BRING SUBSTRATES TO PROPER ELEVATION.
3) PROVIDE ADDITIONAL TOPPING AT LOCATIONS AS DIRECTED AND AS
NECESSARY FOR MOCK-UPS OF STAIN AND SEALER SYSTEMS.
B. PREPARATION
1) SURVEY FLOOR AS NECESSARY TO SET SCREEDS AND REFERENCE
POINTS. IDENTIFY CONSTRUCTION JOINTS, AND CONTROL JOINTS.
PREPARE FOR UNDERLAYMENT AT ALL LOCATIONS WHERE FLOOR
DOES NOT MEET SPECIFIED TOLERANCE REQUIREMENTS.
2) ENSURE THAT SUBFLOOR IS CLEAN, DRY, HARD, SOUND, AND FREE OF
OILS, OR OTHER SUBSTANCE WHICH WOULD AFFECT PROPER BONDING
AND CURING. VERIFY THAT ALL AREAS TO BE LEVELED ARE AT OR
BELOW FINAL DESIGN ELEVATION.
3) COORDINATE WITH PLUMBING WORK AND SECTION 093000 FOR
ESTABLISHMENT OF LEVELS AND PITCHES TO DRAIN.
C. APPLICATION
1) INSTALL TROWELABLE UNDERLAYMENT AT LOCATIONS WHERE SLOPES
ARE INDICATED AND AT OTHER LOCATIONS AS APPROPRIATE TO
INSTALLATION CONDITIONS; INSTALL SELF LEVELING UNDERLAYMENT
AT OTHER LOCATIONS AS NECESSARY TO CORRECT SLAB FLATNESS
AND LEVELNESS.
2) WHERE SUBSEQUENT FINISHING OF THE MATERIAL IS REQUIRED, FLOAT
TO LEVEL SURFACE.
3) APPLY PRIMER TO ALL AREAS TO RECEIVE UNDERLAYMENT; REPEAT
APPLICATION IF NECESSARY TO ACHIEVE PROPER BUILD.
4) MIX MATERIALS AND POUR OR PUMP AND SQUEEGEE INTO PLACE TO
ACHIEVE APPROPRIATE THICKNESS. FINISH TO A SMOOTH LEVEL
SURFACE WITHIN TOLERANCES SPECIFIED FOR CONCRETE FLOORS.
CURE IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.
D. TOLERANCES:
1)
2)
RAMPS AT TRANSITIONS AND SLOPES TO DRAIN: MAXIMUM SLOPE 1/4"
PER FOOT.
DIVISION 04 - MASONRY (NOT USED)
DIVISION 05 - METAL
GENERAL
A. SECTION INCLUDES:
1) EXTERIOR LIGHTGAGE (AXIAL AND TRANSVERSE) LOAD BEARING METAL
FRAMING, WITH ANCHORAGE AND BRACING.
2) STRUCTURAL DESIGN OF SYSTEMS.
B. SYSTEM DESCRIPTION
1) STRUCTURAL DESIGN:
A) SIZE AND ARRANGE MEMBERS TO SUPPORT DEAD LOADS, AND TO
RESIST LIVE LOADS INDICATED ON THE STRUCTURAL DRAWINGS,
AND INCLUDING WIND LOADS IN ACCORDANCE WITH THE LOCAL
JURISDICTIONAL REQUIREMENTS.
B) DESIGN SYSTEM TO RESIST 100 PERCENT OF THE DESIGN LOAD
WITH A MAXIMUM DEFLECTION OF L/360.
C) DESIGN SYSTEM TO ACCOMMODATE BUILDING DEFLECTION,
DYNAMIC BUILDING MOVEMENT, AND TEMPERATURE VARIATIONS
WITHOUT DAMAGE TO SYSTEM COMPONENTS. DESIGN SYSTEMS TO
ACCOMMODATE A FLOOR DEFLECTION OF 3/4 INCH.
2) CONFIGURATION:
A) PROVIDE FRAMING OF DEPTH INDICATED ON THE DRAWINGS.
B) WHERE STUD GAGE IS INDICATED ON THE DRAWINGS, PROVIDE
STUDS OF INDICATED OR HEAVIER GAGE.
C) WHERE STUD SPACING IS INDICATED ON THE DRAWINGS, PROVIDE
ADDITIONAL STUDS OR CLOSER SPACING AS NECESSARY TO MEET
DESIGN REQUIREMENTS.
D) IN ADDITION TO COLD FORMED METAL FRAMING INDICATED ON THE
DRAWINGS, PROVIDE ADDITIONAL MEMBERS LOCATED AS
NECESSARY TO ANCHOR SUPERIMPOSED LOADS.
C. SUBMITTALS
1) SHOP DRAWINGS:
A) INDICATE TYPICAL AND SPECIAL DETAILS, INCLUDING FRAMING
DETAILS, ANCHORAGE SYSTEMS, FASTENING SYSTEMS, LOADS, AND
ACCESSORIES OR ITEMS REQUIRED OF OTHER WORK FOR
COMPLETE INSTALLATION.
B) INCLUDE DESIGN ENGINEER'S SEAL, IF REQUIRED.
D. QUALITY ASSURANCE
1) USE ONLY WELDERS CERTIFIED BY AWS, OR AS OTHERWISE REQUIRED
BY THE AHJ. .
2) WELDING: AWS D1.3.
3) STRUCTURAL DESIGN: EXCEPT WHERE SIZES, SPACING, CONNECTIONS,
AND SPECIAL FRAMING CONDITIONS ARE SPECIFICALLY INDICATED ON
THE STRUCTURAL DRAWINGS, FRAMING SYSTEMS SHALL BE DESIGNED
BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN STATE WHERE
PROJECT IS LOCATED.
2.
PRODUCTS
A. COMPONENTS
1) COLD FORMED LIGHT-GAGE STEEL FRAMING: ASTM A653; MINIMUM G60
GALVANIZED COATING.
2) FABRICATE FROM STEEL SHEET; QUALITY SQ, GRADE 50; MINIMUM 16
GAGE.
3) FINISH: G60 ZINC COATED FINISH IN ACCORDANCE WITH ASTM A653.
4) STUDS: C SHAPED SECTIONS; MINIMUM 1-5/8 INCH WIDE FLANGES WITH
RETURN LIP.
B. ACCESSORIES:
1) SCREWS: ASTM C954; SELF DRILLING, SELF TAPPING; PAN HEAD;
GALVANIZED OR FLUOROPOLYMER COATED STEEL.
2) SILL GASKET: CLOSED CELL POLYETHYLENE FOAM, GLASS FIBER
STRIPS, OR APPROVED; CONTINUOUS ROLLS; WIDTH OF SILL PLATE.
3.
EXECUTION
A. INSTALL LIGHTGAGE STRUCTURAL FRAMING IN ACCORDANCE WITH ASTM
C1007, UNLESS INDICATED OR SPECIFIED OTHERWISE.
B. PLACE SILL GASKET UNDER RUNNERS FOR EXTERIOR PARTITIONS.
PUNCTURE GASKET CLEAN AND FIT TIGHT TO PROTRUDING FOUNDATION
ANCHOR BOLTS.
C. UNLESS OTHERWISE INDICATED, SCREW OR WELD EACH JOINT. WELD IN
ACCORDANCE WITH AWS D1.3.
D. SAW OR SHEAR CUT METAL FRAMING MEMBERS . NO TORCH CUTTING
PERMITTED.
E. ERECT STUDS IN ONE PIECE FULL LENGTH. SPLICING AND WIRE TYING OF
FRAMING COMPONENTS SHALL NOT BE USED.
F. CONSTRUCT CORNERS WITH A MINIMUM OF 3 STUDS PER CORNER.
G. TOLERANCES:
1) PLUMB: 1/8 INCH IN 10 FEET.
2) LOCATION: WITHIN 1/4 INCH OF THE REQUIRED LOCATION.
3) LEVEL: 1/8 INCH IN 10 FEET.
H. TOUCH-UP FIELD WELDS AND SCRATCHED OR DAMAGED GALVANIZING IN
ACCORDANCE WITH REQUIREMENTS OF ASTM A780.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
055000 - METAL FABRICATIONS
1.
GENERAL
A. SECTION INCLUDES:
1) STEEL FABRICATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS
AND NOT SPECIFIED IN OTHER SECTIONS.
2) MISCELLANEOUS ORNAMENTAL METAL FABRICATIONS, INCLUDING
DECORATIVE EXPOSED STRUCTURAL ELEMENTS.
B. SHOP DRAWINGS: INDICATE PROFILES, SIZES, CONNECTION
ATTACHMENTS, REINFORCING, SIZES AND TYPES OF FASTENERS, FINISHES,
AND ACCESSORIES.
2.
PRODUCTS:
A. STEEL
1) STEEL PLATE, BARS, SHAPES: ASTM A36.
2) TUBES: ASTM A500 OR A501.
3) PIPE: ASTM A53, SEAMLESS, TYPE S, PLAIN END; SCHEDULE 40 UNLESS
INDICATED OTHERWISE.
B. STAINLESS STEEL: ASTM A167; TYPE 304.
C. FASTENERS:
1) AS APPROPRIATE TO THE APPLICATION; COMPATIBLE WITH MATERIALS
BEING FASTENED; GALVANIZED WHERE INDICATED FOR USE IN
EXTERIOR OR DAMP LOCATIONS..
2) BOLTS AND NUTS: ASTM A307
D. FABRICATION:
1) AS INDICATED, AND IN ACCORDANCE WITH APPROVED SHOP
DRAWINGS.
2) FOR ITEMS EXPOSED TO VIEW OR SUBJECT TO CONTACT, GRIND
WELDS SMOOTH AND LEVEL WITH ADJACENT SURFACES; REMOVE ALL
BURRS FROM CUT EDGES.
3) STAINLESS STEEL WATER HEATER PAN: FABRICATE FROM MINIMUM 24
GAGE STAINLESS STEEL; SOLDERED CORNERS; HEMMED EDGES.
4) SHOP FINISHES:
A) GALVANIZED:
(1) CONCEALED: NO FURTHER FINISH
(2) EXPOSED TO VIEW: AS INDICATED.
B) UNGALVANIZED STEEL: FACTORY PRIME PAINTED AFTER
FABRICATION.
C) OTHER METAL FABRICATIONS: AS DIRECTED.
S
0334
PROJECT NUMBER: 16-059
A) EXECUTE FINAL CLEANING PRIOR TO FINAL PROJECT ASSESSMENT.
B) CLEAN INTERIOR AND EXTERIOR GLASS, SURFACES EXPOSED TO VIEW;
REMOVE TEMPORARY LABELS, STAINS AND FOREIGN SUBSTANCES, POLISH
TRANSPARENT ANDGLOSSY SURFACES.
C) CLEAN EQUIPMENT AND FIXTURES TO A SANITARY CONDITION WITH
CLEANING MATERIALS APPROPRIATE TO THE SURFACE AND MATERIAL BEING
CLEANED.
D) REPLACE FILTERS OF OPERATING EQUIPMENT.
E) CLEAN DEBRIS FROM ROOFS, GUTTERS, DOWNSPOUTS, AND DRAINAGE
SYSTEMS.
F) CLEAN SITE; SWEEP PAVED AREAS.
G) REMOVE WASTE AND SURPLUS MATERIALS, RUBBISH, AND CONSTRUCTION
FACILITIES FROM THE SITE.
LIST OF SUBCONTRACTORS AND SUPPLIERS.
CONSTRUCTION SCHEDULE.
D) SUBMITTAL LOG. PRODUCTS LIST.
GENERAL SUBMITTAL REQUIREMENTS
1) MAKE SUBMITTALS AS REQUESTED, AS REQUIRED BY INDIVIDUAL
SPECIFICATION SECTIONS, AND AS OTHERWISE NECESSARY TO
CONFIRM INTENT OR COMPLIANCE. SUBMITTALS FOR OWNER
FURNISHED PRODUCTS ARE NOT REQUIRED.
2) REVIEW SUBMITTAL MATERIALS PRIOR TO SUBMITTAL. VERIFY
SPECIFIED REQUIREMENTS FOR PRODUCTS, FIELD MEASUREMENTS,
AND FIELD CONSTRUCTION REQUIREMENTS.
3) STAMP AND SIGN EACH SUBMITTAL AS CERTIFICATION THAT THE
SUBMITTAL HAS BEEN REVIEWED BY THE CONTRACTOR. SUBMITTALS
NOT STAMPED AND SIGNED BY THE CONTRACTOR WILL BE RETURNED.
4) NOTE IN WRITING, AT TIME OF SUBMITTAL, ALL DEVIATIONS IN THE
SUBMITTALS FROM REQUIREMENTS OF THE CONTRACT DOCUMENTS.
5) MAKE COPIES OF ALL APPROVED SHOP DRAWINGS AND PRODUCT
LITERATURE AVAILABLE FOR USE IN THE PROJECT.
6) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR THE PROPER FITTING,
FINISHING, QUANTITIES, AND ERECTION OF THE WORK IN STRICT
ACCORDANCE WITH THE CONTRACT REQUIREMENTS.
7) REVIEW AND APPROVAL OF A SUBMITTAL SHALL NOT RELIEVE THE
CONTRACTOR FROM THE RESPONSIBILITY FOR PROVIDING WORK NOT
INDICATED ON THE SUBMITTAL, BUT OTHERWISE REQUIRED FOR THE
COMPLETION OF THE WORK.
8) DO NOT FABRICATE OR ERECT WORK PRIOR TO APPROVAL OF THE
SUBMITTALS.
9) SHOULD DISCREPANCIES BECOME EVIDENT, IMMEDIATELY NOTIFY
ARCHITECT FOR RESOLUTION BEFORE PROCEEDING WITH SHOP WORK.
10) INCLUSION OF SUBSTITUTION REQUESTS INTO SUBMITTALS WILL BE
CONSIDERED CAUSE FOR REJECTION OF THE SUBMITTAL.
11) SUBMITTALS WILL BE REVIEWED FOR CONFORMANCE TO THE DESIGN
CONCEPT, ONLY. REVIEW OF VENDOR DESIGNED ITEMS SHALL NOT
RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR COMPLIANCE
WITH SPECIFIED PERFORMANCE REQUIREMENTS.
CONSTRUCTION SCHEDULE
1) SHOW COMMENCEMENT AND COMPLETION DATES PROPOSED FOR
EACH SUBDIVISION OF WORK.
2) COORDINATE WITH THE OWNER'S SCHEDULE, SHOWING ALL CONTRACT
ACTIVITIES TO BE PERFORMED BY THE OWNER INCLUDING THEIR
START, DURATION, COMPLETION, FLOAT AND CRITICAL PATH.
SHOP DRAWINGS
1) SUBMIT SHOP DRAWINGS REQUIRED BY INDIVIDUAL SECTIONS OF THE
SPECIFICATIONS, AND AS OTHERWISE REQUIRED FOR PROPER
PERFORMANCE OF THE WORK.
2) ILLUSTRATE FULLY THE REQUIREMENTS OF THE SPECIFICATIONS AND
THE CONTRACT DRAWINGS, AND ACCURATELY SHOW QUANTITIES,
KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALL DATA
REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION.
3) SHOW THE RELATIONSHIP OF ADJOINING WORK, RELEVANT FIELD
CONDITIONS AND DIMENSIONS; COORDINATE WITH AFFECTED
SUBCONTRACTORS AND SUPPLIERS IF IN CONFLICT.
4) NUMBER OF COPIES: UNLESS OTHERWISE SPECIFIED, SUBMIT 2
LEGIBLE RIGHT-READING COPIES TO THE ARCHITECT, POTBELLY FOR
REVIEW.
5) THE ARCHITECT, POTBELLY WILL RETURN ONE COPY TO CONTRACTOR
WITH CORRECTIONS, NOTATIONS AND STAMP INDICATING ACTION TO
BE TAKEN.
PRODUCT DATA
1) MARK EACH COPY TO IDENTIFY APPLICABLE PRODUCTS, MODELS,
OPTIONS, AND OTHER DATA. INCLUDE MANUFACTURER'S PRINTED
INSTALLATION INSTRUCTIONS.
2) SUBMIT THE NUMBER OF COPIES WHICH CONTRACTOR REQUIRES, PLUS
1COPY WHICH WILL BE RETAINED BY ARCHITECT, POTBELLY.
3) MODIFY PRODUCT DATA AND INSTALLATION INSTRUCTIONS TO DELETE
INFORMATION WHICH IS NOT APPLICABLE TO THE WORK.
4) SUPPLEMENT STANDARD INFORMATION TO PROVIDE INFORMATION
SPECIFICALLY APPLICABLE TO THE WORK.
SAMPLES
1) SUBMIT SAMPLES AS SPECIFIED IN THE TECHNICAL SECTIONS.
2) INCLUDE IDENTIFICATION ON EACH SAMPLE, GIVING FULL INFORMATION.
3) SUBMIT THE NUMBER OF SAMPLES SPECIFIED IN THE TECHNICAL
SECTIONS. WHERE QUANTITY IS NOT SPECIFIED, SUBMIT 3 SAMPLES.
4) SUBMIT SAMPLES TO ILLUSTRATE FUNCTIONAL CHARACTERISTICS OF
THE PRODUCT, WITH INTEGRAL PARTS AND ATTACHMENT DEVICES.
COORDINATE SUBMITTAL OF DIFFERENT CATEGORIES FOR
INTERFACING WORK.
SUSTAINABLE DESIGN AND CONSTRUCTION
1) FOR WORK UNDER EACH SUBCONTRACT OR SPECIFICATION SECTION,
MAKE SUBMITTALS AS NECESSARY TO SUPPORT EACH APPLICABLE
CREDIT, AS DESCRIBED IN SECTION 018113.
2) MAKE SUBMITTALS AS NECESSARY TO SUPPORT PROCEDURAL
REQUIREMENTS, INCLUDING WASTE MANAGEMENT AND INDOOR AIR
QUALITY MANAGEMENT PLANS, AS DESCRIBED IN SECTION 018113.
B)
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ARTICLE 32 - FINAL CLEANING
SHEET TITLE
ARCHITECTURAL
SPECIFICATIONS
SHEET NUMBER
AS1.1
GENERAL
A. SECTION INCLUDES: SUPPORTS FOR CEILING FINISHES AND FIXTURES.:
B. SYSTEM DESCRIPTION
1) SUPPORT FRAMING SHALL BE STEEL UNLESS APPROVED OTHERWISE.
USE PROPRIETARY CHANNEL SUPPORT SYSTEMS WITH
SUPPLEMENTARY SHOP FABRICATED STEEL SECTIONS AS
APPROPRIATE TO THE INSTALLATION.
2) CONFIGURATIONS: SIZE MEMBERS AND SELECT ANCHORAGE SYSTEMS
TO SUPPORT THE DEAD LOAD AS WELL AS LIVE OPERATIONAL LOADS;
SAFETY FACTOR: 2.5 BASED ON ULTIMATE STRENGTH UNDER STATIC
LOAD CONDITIONS.
C. SUBMITTALS
1) PRODUCT LITERATURE.
2) SHOP DRAWINGS: SHOW DETAILS OF FABRICATION AND INSTALLATION;
INDICATE MATERIALS, DIMENSIONS, ATTACHMENTS, PROPRIETARY
CHANNEL SUPPORT SYSTEM PRODUCT NUMBERS, PROVISIONS FOR
WORK OF OTHER TRADES, AND OTHER PERTINENT INFORMATION AS
NECESSARY TO COORDINATE THE WORK.
D. STRUCTURAL DESIGN: SUPPORTS FOR OVERHEAD EQUIPMENT NOT
SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS SHALL BE
DESIGNED BY A STRUCTURAL ENGINEER LICENSED TO PRACTICE IN THE
STATE OF WASHINGTON. .
2.
PRODUCTS
A. PROPRIETARY CHANNEL SUPPORT SYSTEMS:
1) MANUFACTURER: UNISTRUT (SPOKANE, WA; 509-535-9841).
2) SYSTEM: P1000.
3) FINISH: "PERMA-GREEN" RUST INHIBITING ELECTRO-DEPOSITED
ACRYLIC ENAMEL.
3.
EXECUTION:
A. INSTALL IN ACCORDANCE WITH THE APPROVED SHOP DRAWINGS.
FREE FROM ADDED UREA-FORMALDEHYDE.
H. FASTENERS
1) JOIST HANGERS: AS INDICATED.
2) LAG BOLTS: 3/8" X LENGTHS AS APPROPRIATE TO THE APPLICATION;
UNFINISHED.
3) MISCELLANEOUS HARDWARE: FURNISH NAILS, WASHERS AND OTHER
FASTENERS AS NECESSARY TO COMPLETE THE WORK.
I. FABRICATION
1) SHOP FABRICATE ALL TRIM TO THE SHAPES INDICATED.
2) UNLESS OTHERWISE SCHEDULED, STANDING AND RUNNING TRIM TO
RECEIVE OPAQUE FINISH MAY BE FABRICATED FROM MDF OR LUMBER
AS SPECIFIED.
3) SHOP FIT AND ASSEMBLE TO THE GREATEST EXTENT PRACTICAL.
4) BACK OR KERF CUT ALL TRIM GREATER THAN 2 INCH IN WIDTH, EXCEPT
TERMINATE BEFORE EXPOSED ENDS.
3.
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
061000 - ROUGH CARPENTRY
1.
2.
3.
GENERAL
A. SECTION INCLUDES:
1) BLOCKING, NAILERS, AND CURBING.
2) PLYWOOD TERMINAL BACKBOARD
3) WATER HEATER PLATFORM
B. SYSTEM DESCRIPTION BACKING: WHERE CONCEALED BACKING IS
INDICATED OR REQUIRED IN STEEL FRAMED WALLS, PROVIDE WOOD OR
METAL BACKING AT CONTRACTOR'S OPTION
PRODUCTS
A. DIMENSION LUMBER: IN ACCORDANCE WITH PS 20; STAMPED AND GRADED
IN ACCORDANCE WITH WWPA OR WCLB GRADING RULES.
1) MOISTURE CONTENT: KILN DRIED TO 19% MAXIMUM MOISTURE
CONTENT, EXCEPT FOR MATERIAL WHOSE LEAST DIMENSION IS 4
INCHES THICK OR GREATER.
2) SPECIES: HEM-FIR, SPRUCE-PINE-FIR (SPF), OR DOUGLAS FIR LARCH,
UNLESS INDICATED OR SPECIFIED OTHERWISE.
3) UNEXPOSED NON-STRUCTURAL WOOD FRAMING AND BLOCKING
GRADED AS FOLLOWS:
A) MEMBERS 2" TO 4" THICK, 2" TO 4" WIDE: "NO 2 - STRUCTURAL LIGHT
FRAMING," OR BETTER; "STUD" GRADE MAY BE USED AT STUD
APPLICATIONS
B) MEMBERS 2" TO 4" THICK, 5" AND WIDER: "NO. 2 - STRUCTURAL
JOISTS AND PLANKS," OR BETTER.
B. PLYWOOD BACKING(CONCEALED) AND SHEATHING: APA RATED
SHEATHING; CD GRADE; EXTERIOR; PLYWOOD, UNLESS APPROVED
OTHERWISE; THICKNESSES AS INDICATED.
C. TERMINAL BACKBOARDS: APA AC GRADE EXTERIOR; FIRE RETARDANT
TREATED.
D. FASTENERS:
1) HOT-DIPPED GALVANIZED STEEL OR COPOLYMER COATED FOR
EXTERIOR, HIGH HUMIDITY, AND TREATED WOOD LOCATIONS.
2) SCREWS: SELF TAPPING; COUNTERSUNK OR LOW PROFILE HEAD.
E. FIRE RETARDANT TREATMENT:
1) FIRE RETARDANT TREAT ALL INTERIOR CONCEALED LUMBER AND
PLYWOOD, AND OTHER WOOD AS INDICATED OR REQUIRED.
2) ALL FIRE RETARDANT TREATED WOOD MATERIALS SHALL BEAR A UL
"FR-S" LABEL, OR A LABEL FROM AN APPROVED INSPECTION AGENCY
CERTIFYING THAT THE MATERIAL MEETS THE REQUIREMENTS OF AWPA
C_20 TYPE A FOR LUMBER AND AWPA C-27 TYPE A FOR PLYWOOD.
3) TREATED LUMBER SHALL BE KILN DRIED TO A MAXIMUM MOISTURE
CONTENT OF 19%; TREATED PLYWOOD SHALL BE KILN DRIED TO A
MAXIMUM MOISTURE CONTENT OF 15 PERCENT.
2.
3.
2.
PRODUCTS
A. FIREPROOFING MATERIAL: FURNISH ONE IF THE FOLLOWING, AS
APPROPRIATE FOR PATCHING EXISTING FIREPROOFING.
1)
ISOLATEK INTERNATIONAL "CAFCO 300," OR APPROVED CEMENTITIOUS
FIREPROOFING.
B.
GENERAL
A. SECTION INCLUDES:
1) STANDING AND RUNNING TRIM.
2) EXPOSED FRAMING
3) INSTALLATION OF OWNER FURNISHED WOODWORK
B. SHOP DRAWINGS: FOR ITEMS FURNISHED UNDER THIS CONTRACT,
INDICATE MATERIALS, COMPONENTS, PROFILES AND CONFIGURATIONS,
DIMENSIONS, FASTENING METHODS, JOINTING DETAILS, COLORS AND
FINISHES, AND ACCESSORIES.
C.
SPRAY APPLIED FIREPROOFING MATERIAL.
QUALIFICATIONS:
1) REPLACEMENT FIREPROOFING MATERIAL SHALL HAVE BEEN TESTED
AND REPORTED BY UL IN ACCORDANCE WITH PROCEDURES OF ASTM
E119.
2) THE FIREPROOFING PRODUCT SHALL BE TESTED IN ACCORDANCE WITH
ASTM STANDARD G_21_75, AND SHALL SHOW RESISTANCE TO MOLD
GROWTH. MOLD INHIBITOR SHALL BE ADDED BY THE MANUFACTURER.
A) SURFACE BURNING CHARACTERISTICS: IN ACCORDANCE WITH
ASTM E84:
B) FLAME SPREAD: 0
C) SMOKE DEVELOPMENT: 0
EXECUTION
1) PREPARATION
A) VERIFY THAT ALL SURFACES TO RECEIVE SPRAYED REPLACEMENT
FIREPROOFING ARE FREE OF FOREIGN SUBSTANCES WHICH MAY
IMPAIR PROPER ADHESION OF THE FIREPROOFING TO THE
PRODUCTS
A. FACED BATT AND BLANKET INSULATION:
1) JOHNS MANVILLE CORP. "FSK_25," OWENS-CORNING FIBERGLAS CORP.
"FLAME SPREAD 25," KNAUF INSULATION (800-825-4434) "ECOBATT
FSK-FOIL FACED," OR APPROVED.
ACCESSORIES
TAPE: MATCH VAPOR RETARDER; 2 INCH WIDTH.
2) FURNISH OTHER ACCESSORIES, NOT SPECIFICALLY DESCRIBED, BUT
REQUIRED FOR SECURE AND TIGHT INSTALLATION OF INSULATION WITH
COMPLETE INSULATION FILL WITHIN CAVITIES, AND CONTINUOUS
VAPOR RETARDER.
E. ADHESIVE:
1) TYPE RECOMMENDED BY INSULATION MANUFACTURER FOR
APPLICATION; COMPATIBLE WITH INSULATION AND SUBSTRATE.
2) TOXICITY/IEQ: COMPLY WITH APPLICABLE REGULATIONS REGARDING
TOXIC AND HAZARDOUS MATERIALS, GS-36 FOR COMMERCIAL
ADHESIVE AND SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT
RULE 1168.
3.
3.
EXECUTION
A. INSTALL INSULATION WITHOUT GAPS OR VOIDS.
B. TRIM INSULATION NEATLY TO FIT SPACES. USE BATTS FREE OF DAMAGE.
C. WALL INSULATION AND VAPOR RETARDER
1) AT METAL STUD FRAMING, INSTALL UNFACED BATT WITH EDGES
TIGHTLY SET INTO THE STUD CHANNELS FOR A FRICTION FIT. PROVIDE
ADDITIONAL SUPPORTS AS NECESSARY TO PREVENT SLIDING OF BATTS
IN THE STUD CAVITY.
2) SEPARATE VAPOR BARRIER INSTALLATION:
A) INSTALL SEPARATE VAPOR BARRIER OVER UNFACED INSULATION.
B) INSTALL VAPOR BARRIER TOWARD WARM SIDE OF BUILDING
SPACES.
C) VAPOR BARRIER SHALL BE CONTINUOUS.
D) AT LIGHTGAGE SUPPORT FRAMING, SECURE TO STUDS WITH
DOUBLE STICK TAPE OR SPRAY ADHESIVE.
E) LAP JOINTS IN VAPOR BARRIER 2 INCHES, EXCEPT PROVIDE TAPE
SEALED JOINTS AT LOCATIONS WHERE VAPOR BARRIER WILL
REMAIN EXPOSED IN THE FINISHED WORK.
F) TAPE SEAL VAPOR BARRIER TO ADJACENT CONSTRUCTION AT
PERIMETER EDGES.
G) TAPE AND SEAL TEARS OR CUTS IN VAPOR BARRIER.
D. CEILING INSULATION: INSTALL FACED BATTS OVER CEILING WITH ENDS
AND EDGES TIGHTLY BUTTED WITHOUT GAPS. SECURE WITH ADHESIVE AS
APPROPRIATE.
E. SITE ENVIRONMENTAL PROCEDURES:
1) WASTE MANAGEMENT: AS SPECIFIED IN SECTION 018113 AND AS
FOLLOWS:
2) COORDINATE WITH MANUFACTURER FOR TAKE-BACK PROGRAM. SET
ASIDE SCRAP TO BE RETURNED TO MANUFACTURER FOR RECYCLING
INTO NEW PRODUCT.
GENERAL
A. SECTION INCLUDES: FIRESTOPPING SYSTEMS FOR SEALING
PENETRATIONS THROUGH FIRE-RATED CONSTRUCTION.
B. PERFORMANCE REQUIREMENTS
1) EACH FIRESTOPPING SYSTEM SHALL BE SELECTED TO MAINTAIN FIRE
RATING OF THE ASSEMBLY IN WHICH IT IS USED.
2) WHERE PENETRATION FIRESTOPPING IS USED TO SEAL PENETRATIONS
THROUGH FLOORS WITH WATERPROOF MEMBRANES, SYSTEM SHALL
BE SELECTED FOR COMPATIBILITY WITH MEMBRANE MATERIAL.
3) PROVIDE PRODUCTS THAT UPON CURING, DO NOT RE-EMULSIFY,
DISSOLVE, LEACH, BREAKDOWN OR OTHERWISE DETERIORATE OVER
TIME FROM EXPOSURE TO ATMOSPHERIC MOISTURE, SWEATING PIPES,
PONDING WATER OR OTHER FORMS OF MOISTURE CHARACTERISTIC
DURING AND AFTER CONSTRUCTION.
4) PROVIDE FIRESTOP SEALANTS SUFFICIENTLY FLEXIBLE TO
ACCOMMODATE MOTION SUCH AS PIPE VIBRATION, WATER HAMMER,
THERMAL EXPANSION AND OTHER NORMAL BUILDING MOVEMENT
WITHOUT DAMAGE TO THE SEAL.
5) PIPE INSULATION SHALL NOT BE REMOVED, CUT AWAY OR OTHERWISE
INTERRUPTED THROUGH WALL OR FLOOR OPENINGS. PROVIDE
PRODUCTS APPROPRIATELY TESTED FOR THE THICKNESS AND TYPE OF
INSULATION UTILIZED.
6) OPENINGS WITHIN WALLS AND FLOORS DESIGNED TO ACCOMMODATE
VOICE, DATA AND VIDEO CABLING SHALL BE PROVIDED WITH
RE-ENTERABLE PRODUCTS SPECIFICALLY DESIGNED FOR RETROFIT.
7) PENETRATIONS THROUGH FIRE-RESISTANCE RATED FLOOR-CEILING
ASSEMBLIES CONTAINED WITHIN CHASE WALL ASSEMBLIES SHALL BE
STRIKE REINFORCEMENT: MINIMUM 16 GAGE.
CLOSER REINFORCEMENT: MINIMUM 14 GAGE.
5) FABRICATION
A) CUT MORTISES FOR BUTTS STRIKES AND OTHER HARDWARE.
PROJECTION WELD HINGE AND STRIKE REINFORCEMENTS TO THE
DOOR FRAME. PROVIDE ADEQUATE REINFORCEMENTS FOR OTHER
HARDWARE AS REQUIRED.
B) FRAMES SHALL BE SHOP ASSEMBLED; CONTINUOUS FACE WELD
JOINT BETWEEN THE HEAD AND JAMB FACES.
C) GRIND AND FINISH SMOOTH FACE JOINTS WITH NO VISIBLE FACE
SEAMS.
C. FINISH: MANUFACTURER'S STANDARD RUST INHIBITIVE DIRECT TO METAL
PRIMER.
1) METAL DOORS
A) MANUFACTURE'S PRIMER
B) G.C. TO PAINT IN FIELD PER DOOR SCHEDULE ON A2.0, 2 COATS, OR
AS MANY AS REQUIRED FOR FULL COVERAGE.
2) WOOD DOORS
1) ONE COAT OF THE ST-02 STAIN.
2) ONE COAT OF THE SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL
AND TOP COAT (SHERWIN WILLIAMS ITEM #M64WXC6146).
3) LIGHT SAND / SCUFF (WIPE CLEAN).
4) ONE LAST COAT OF SHER-WOOD KEMA AQUA 60 DEGREE SELF-SEAL
AND TOP COAT (SHERWIN WILLIAMS ITEM #M64WXC6146).
OLDCASTLE BUILDINGENVELOPE "NS-212 STANDARD DUTY NARROW
STILE."
D) CRL/US ALUMINUM "SERIES 250 ENTRANCE DOORS."
3) ACCESSORIES:
A) FURNISH INSIDE MOUNT COMPENSATION HEAD CHANNELS.
B) TRANSOM DECAL: ("THIS DOOR TO REMAIN UNLOCKED DURING
BUSINESS HOURS")
C) FURNISH SILLS, FASTENERS, ALUMINUM FLASHINGS, WATER
DIVERTERS, SPACERS, GASKETS, SEALANTS, AND ADAPTERS AS
NECESSARY FOR A COMPLETE INSTALLATION.
4) DOOR HARDWARE:
A) WEATHERSTRIPPING: MANUFACTURER'S STANDARD POLY PILE IN
DOOR AND/OR FRAME.
B) OTHER OPERATING HARDWARE: AS SCHEDULED ON THE
DRAWINGS.
D. MATERIALS
1) EXTRUDED ALUMINUM: ANSI/ASTM B221; 6063-T5 ALLOY AND TEMPER.
2) SHEET ALUMINUM: ASTM B209, MINIMUM .019 INCH THICKNESS FOR
C)
B)
C)
EXECUTION
A. PROVIDE FIRESTOPPING AT MECHANICAL, ELECTRICAL, AND PLUMBING
PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS, AND CEILINGS.
B. WHERE FIRESTOPPING IS USED TO SEAL AROUND PENETRATIONS
THROUGH WATERPROOF MEMBRANES, INSTALL TO MAINTAIN INTEGRITY
OF WATERPROOF BARRIER.
C. FOR SEALING ELECTRICAL BOXES, COORDINATE INSTALLATION WITH
DIVISION 26. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR
PREPARATION AND INSTALLATION. INSTALL IN LOCATIONS AS REQUIRED BY
CODE FOR PROTECTION OF OPENINGS THROUGH FIRE RATED PARTITIONS.
D. FILL OPEN HOLES WHICH REMAIN AFTER REMOVAL OF EXISTING
MECHANICAL, ELECTRICAL, AND PLUMBING COMPONENTS. PATCH AND
REPAIR HOLES AS NECESSARY TO MATCH THE ADJACENT CONSTRUCTION
AND TO MAINTAIN THE FIRE RATING OF THE ASSEMBLIES. FIRESTOPPING
SYSTEMS MAY BE USED TO FILL HOLES WHICH WILL BE CONCEALED IN THE
FINISH CONSTRUCTION.
D.
APPLICATIONS.
GLAZING: FURNISHED UNDER SECTION 088000. PROVIDE SHOP GLAZED
UNITS AT CONTRACTOR'S OPTION.
E. FINISH: COLOR ANODIZED: AAMA AA-M12C22A44; ARCHITECTURAL CLASS I,
ETCHED, MEDIUM MATTE, COLORED ANODIC COATING, 0.7 MIL THICKNESS;
DARK BRONZE ANODIZED, UNLESS OTHERWISE DIRECTED OR REQUIRED
TO MATCH EXISTING.
3)
3.
EXECUTION:
INSTALL FRAMES IN ACCORDANCE WITH ANSI A250.11
2) DOOR INSTALLATION IS SPECIFIED IN SECTION 087103.
1)
EXECUTION
A. INSTALL FRAMING IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS.
B. INSTALL SILL PAN IN ROUGH OPENING WITH END DAMS TIGHT TO THE JAMB
FRAMING MEMBERS. PROVIDE SOLID BLOCKING AND ENSURE THAT THE
SILL PAN IS SLOPED TO DRAIN. COORDINATE INSTALLATION TO
ACCOMMODATE INSTALLATION OF FLEXIBLE FLASHING AND BUILDING
PAPER ELEMENTS FLASHED TO WEATHER.
C. WHERE COMPENSATING HEAD CHANNELS ARE USED, SCREW CHANNELS
TO STRUCTURE WITH CENTER OF CHANNEL FIXED AND OTHER FASTENERS
THROUGH SLOTTED HOLES.
D. SCREW ATTACH END DAMS TO SUB-SILL ENDS; SEAL JOINTS BETWEEN DAM
AND SUB-SILL. FASTEN THE SUB-SILL SECURELY INTO THE OPENINGS. CAP
SEAL TOPS OF FASTENERS.
E. COORDINATE INSTALLATION OF DOORS AND HARDWARE, AS SPECIFIED IN
SECTION 087301.
087103 - DOOR HARDWARE AND INSTALLATION
1.
GENERAL:
A. SECTION INCLUDES: SEALANTS FOR INSTALLATION AT INTERIOR
NON-MOVING JOINTS, CERAMIC TILE EXPANSION JOINTS, AND AS
NECESSARY TO SEAL JOINTS AROUND CASEWORK AND PLUMBING
FIXTURES.
2.
PRODUCTS:
A. SEALANTS:
1) TYPE PTNS: ASTM C920, TYPE M, GRADE NS, CLASS 25; PECORA
"DYNATRED," TREMCO "HPL," OR APPROVED; STANDARD COLOR AS
SELECTED FROM THE MANUFACTURER'S COMPLETE LINE OF
PRE-FORMULATED COLORS.
2) TYPE A: ASTM C834; TREMCO "ACRYLIC LATEX CAULK," PECORA
"AC-20+SILICONE," SONNEBORN "SONOLAC," OR APPROVED; STANDARD
COLORS TO MATCH ADJACENT CONSTRUCTION.
3) TYPE S - NEUTRAL CURE SILICONE SEALANT: DOW CORNING, "790
SILICONE BUILDING SEALANT," "795 SILICONE STRUCTURAL GLAZING
AND WEATHERPROOFING SEALANT," OR "CONTRACTORS
WEATHERPROOFING SEALANT"; PECORA "890 FTS SILICONE;" OR
TREMCO INC. "SPECTREM 3."
4) TYPE SM: MILDEW RESISTANT SILICONE SEALANT: USDA APPROVED;
DOW CORNING "786," GE "SANITARY SCS1700," OR APPROVED;
TRANSLUCENT OR WHITE, AS SCHEDULED.
B. PRIMER: AS RECOMMENDED BY RESPECTIVE MANUFACTURERS FOR EACH
APPLICATION.
C. BACKER ROD: CLOSED OR OPEN CELL FOAM AS RECOMMENDED BY THE
SEALANT MANUFACTURER FOR THE APPLICATION; ROUND PROFILE;
THICKNESS APPROXIMATELY 130 PERCENT OF JOINT WIDTH.
3.
078413 - PENETRATION FIRESTOPPING
1.
PRODUCTS
A. SYSTEMS MEETING THE REQUIREMENTS SPECIFIED AND SUITABLE FOR
THE CONDITIONS INDICATED AS MANUFACTURED BY ONE OR MORE OF THE
FOLLOWING.
1) METACAULK.
2) TREMCO INC.
3) HILTI USA.
4) GRACE CONSTRUCTION PRODUCTS.
5) SPECIFIED TECHNOLOGIES, INC.
6) 3M.
B. ELECTRICAL BOX INSERTS:
1) MANUFACTURER: RECTORSEAL (HOUSTON TX; 713_263_8001;
800_231_3345).
2) FIRE RATED PADS: "BIOFIRESHIELD LECTRA-STOP"; 1/4 INCH THICK
INTUMESCENT PADS; SIZED TO FIT ELECTRICAL BOXES; CLASSIFIED BY
UL; MINIMUM 2 HOUR RATING.
079200 - JOINT SEALANTS
1)
070183 - REPLACEMENT FIREPROOFING
GENERAL
A. SECTION INCLUDES:
1) SURFACE PREPARATION AND COORDINATION WORK FOR PATCHING OF
EXISTING AND INCIDENTAL NEW FIREPROOFING WORK.
2) FIREPROOFING MATERIALS.
3) SEALING OF EXISTING FIREPROOFING INDICATED TO REMAIN EXPOSED
IN THE FINISHED WORK.
B. SUBMITTALS: MANUFACTURERS' DATA; INCLUDE INSTRUCTIONS FOR
PROPER APPLICATION OF SPRAYED REPLACEMENT FIREPROOFING.
C. QUALITY ASSURANCE
1) FIREPROOFING WORK SHALL BE PERFORMED BY A FIRM ACCEPTABLE
TO THE SPRAYED REPLACEMENT FIREPROOFING MATERIALS
MANUFACTURER.
2) PRODUCTS, EXECUTION AND FIREPROOFING THICKNESSES SHALL
CONFORM TO THE APPLICABLE CODE REQUIREMENTS FOR THE
FIRE-RESISTANCE RATINGS CALLED FOR.
2.
D.
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
1.
GENERAL
A. SECTION INCLUDES:
1) THERMAL BATT AND BLANKET INSULATION.
2) VAPOR RETARDER.
B. PRODUCT DATA: SUBMIT FOR EACH TYPE OF INSULATION AND VAPOR
RETARDER.
GLASS FIBER ROLL WITH FOIL SCRIM KRAFT FACE; FLAME SPREAD OF
25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN TESTED IN
ACCORDANCE WITH ASTM E84.
3) MINIMUM 20 PERCENT CALCULATED (BASED ON SUM OF PERCENTAGE
OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF PRE-CONSUMER)
RECYCLED CONTENT.
4) THICKNESS AS NECESSARY TO ACHIEVE MINIMUM R-13 THERMAL
RESISTANCE.
B. UNFACED BATT AND BLANKET INSULATION:
1) JOHNS MANVILLE CORP. "UNFACED FORMALDEHYDE-FREE THERMAL
AND ACOUSTICAL FIBER GLASS INSULATION," KNAUF INSULATION
(800-825-4434) "ECOBATT," OR APPROVED.
2) ASTM C665, TYPE I; PREFORMED UNFACED GLASS FIBER BATTS; FLAME
SPREAD OF 25 OR LESS AND SMOKE DEVELOPED OF 50 OR LESS WHEN
TESTED IN ACCORDANCE WITH ASTM E84.
3) UNFACED FORMALDEHYDE-FREE GLASS FIBER COMMERCIAL
INSULATION; OVERSIZE WIDTHS FOR FRICTION-FIT BETWEEN METAL
FRAMING MEMBERS; MINIMUM 20 PERCENT CALCULATED (BASED ON
SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE
OF PRE-CONSUMER) RECYCLED CONTENT.
4) THICKNESS AS INDICATED ON THE DRAWINGS.
C. VAPOR RETARDER: CERTAINTEED CORPORATION (VALLEY FORGE PA;
610_341_7000; 800_233_8990) "MEMBRAIN"; 2 MIL POLYAMIDE FILM; FLAME
EXECUTION
A. INSTALL CASEWORK AS DIRECTED.
B. COORDINATE WITH OWNER TO ACCOMMODATE CASEWORK INSTALLATION,
AS NECESSARY.
062213 - INTERIOR FINISH CARPENTRY
PRODUCTS
A. CONCEALED FRAMING LUMBER: PINE, FIR, HEMLOCK, OR OTHER SPECIES
AS APPROVED; MAXIMUM MOISTURE CONTENT 10 PERCENT.
B. EXPOSED LUMBER FOR OPAQUE FINISH: ALDER, POPLAR OR SIMILAR
APPROVED HARDWOOD; AWS CUSTOM GRADE.
C. EXPOSED FRAMING LUMBER: PS20; SELECT B&BTR.
TO MEET THE HOURLY FIRE RATINGS OF THE CONSTRUCTION BEING
SEALED. PROVIDE F RATED ASSEMBLIES, EXCEPT WHERE T RATED
ASSEMBLIES ARE REQUIRED BY THE CODE AUTHORITY.
2)
PRODUCTS
A. FURNISH WOOD AND STEEL BLOCKING AS SPECIFIED IN SECTION 092200.
B. COORDINATE WITH OTHER TRADES AS NECESSARY FOR PROPER
INCORPORATION OF UTILITIES AND INTERFACE WITH FINISHES.
2)
2.
2.
EXECUTION
A. INSTALLATION
1) JOINTING: MAKE ALL JOINTS TO CONCEAL SHRINKAGE; MITER ALL
EXTERIOR CORNERS; COPE ALL INTERIOR CORNERS, MITER OR SCARF
ALL END-TO-END JOINTS; INSTALL ALL TRIM PIECES AS LONG AS
POSSIBLE, JOINTING ONLY WHERE SOLID SUPPORT IS OBTAINED. MAKE
NO JOINTS CLOSER THAN 4 FEET TO CORNERS.
2) LENGTHS OF MATERIAL: USE RANDOM LENGTHS AND SHOW TYPICAL
JOINT LOCATIONS ON SHOP DRAWINGS. THE MINIMUM LENGTH SHALL
BE 8 FEET, EXCEPT WHERE SHORT LENGTHS ARE REQUIRED BY
INSTALLATION CONDITIONS.
3) FASTENING:
A) INSTALL ALL ITEMS STRAIGHT, TRUE, LEVEL, PLUMB, AND FIRMLY
ANCHORED IN PLACE; WHERE BLOCKING OR BACKING IS REQUIRED,
COORDINATE AS NECESSARY WITH OTHER TRADES TO ENSURE
PLACEMENT OF ALL REQUIRED BACKING AND BLOCKING IN A TIMELY
MANNER.
B) FASTEN TRIM WITH FINISH NAILS OR TRIM HEAD SCREWS OF
PROPER DIMENSION TO HOLD THE MEMBER FIRMLY IN PLACE
WITHOUT SPLITTING THE WOOD.
C) ON EXPOSED FINISH WORK, SET ALL NAILS AND SCREWS.
D) ALIGN EXPOSED FASTENERS FOR UNIFORM PATTERN; RANDOM OR
"SHOTGUN" PATTERNS WILL NOT BE ACCEPTED.
B. PUTTY FILL ALL EXPOSED FASTENER HOLES AND LEVEL WITH SURFACE.
FOR TRIM INDICATED FOR TRANSPARENT FINISH; USE COLOR MATCHED
PUTTY; SEQUENCE WITH FINISHING TO AVOID SOLVENT STAINING.
GENERAL
A. SECTION INCLUDES:
1) INSTALLATION OF OWNER FURNISHED CASEWORK AND SHELVING.
2) COORDINATION WITH OWNER FOR INSTALLATION OF CASEWORK BY
THE OWNER AND/OR OWNER'S VENDOR.
B. SHOP DRAWINGS: INDICATE LOCATIONS OF WALL MOUNTED CASEWORK
AND BLOCKING.
C. OBTAIN TEMPLATES, SHOP DRAWINGS, AND INSTALLATION INSTRUCTIONS
FROM OWNER'S VENDOR(S), AS NECESSARY TO FACILITATE PROPER
INSTALLATION.
1.
A.
1.
1.
064100 - ARCHITECTURAL CASEWORK
EXECUTION
FRAMING HAS BEEN CONFIGURED OR DESIGNED TO SUPPORT RESPECTIVE
COMPONENTS, INSTALL WOOD BLOCKING TO RECEIVE MECHANICAL
FASTENERS FOR SUPPORT OF PLUMBING AND ELECTRICAL FIXTURES AND
EQUIPMENT, CABINETS, DOOR STOP PLATES, WOOD BASE, WAINSCOTS,
COAT HOOKS, TOILET AND BATH ACCESSORIES, AND ALL OTHER WALL AND
CEILING MOUNTED COMPONENTS.
B. SCREW FASTEN WOOD COMPONENTS TO METAL FRAMING AND SUPPORT
ELEMENTS.
C. FOR ATTACHMENT OF PLYWOOD BACKING, KERF PLYWOOD 1/4" (3/8",
MAXIMUM IF REQUIRED FOR HEAVY GAGE STUDS) TO RECEIVE FLANGE
RETURN (OR CRIMP THE RETURN CLOSED); PROVIDE SUPPLEMENTARY
SHEET METAL ANGLE ATTACHED TO BACK OF STUD WHERE NECESSARY TO
SUPPORT BACKING. SCREWS INTO EDGE OF PLYWOOD ARE
UNACCEPTABLE.
2)
072117 - FIBROUS BUILDING INSULATION
3)
UNIVERSAL NON-HANDED PREPARATION OF DOORS IS NOT
ACCEPTABLE. INSTALL REINFORCEMENTS, WELDED IN PLACE.
D) REINFORCE TOP AND BOTTOM OF DOORS WITH 14 GAGE CHANNELS,
WELDED TO BOTH FACE PANELS.
B. FRAME
1) ANSI A250.8; DOUBLE EQUAL RABBET, UNLESS INDICATED OTHERWISE.
2) MATERIAL: COLD-ROLLED STEEL, ASTM A1008; MINIMUM 16 GAGE (.053
INCH)
3) ACCESSORIES: FURNISH NECESSARY ANCHORS FOR JAMBS, HEADS,
AND SILLS OF ASSEMBLIES.
4) FRAME HARDWARE REINFORCEMENTS
A) MORTISE HINGE REINFORCEMENT: MINIMUM 7 GAGE: FURNISH HIGH
FREQUENCY HINGE REINFORCEMENT FOR TOP HINGE ON ALL
EXTERIOR, CROSS CORRIDOR, AND STAIRWELL FRAMES, IN
PROTECTED WITH PRODUCTS TESTED BY BEING FULLY EXPOSED TO
THE FIRE OUTSIDE OF THE CHASE WALL.
C. QUALITY ASSURANCE
1) CODE VERIFICATION: PRIOR TO INSTALLATION OF FIRE STOPPING
SYSTEMS OBTAIN APPROVAL FROM THE JURISDICTIONAL CODE
AUTHORITIES FOR THE FIRE STOPPING SYSTEMS AND APPLICATIONS
PROPOSED.
B)
EXECUTION:
A. PERFORM WORK IN ACCORDANCE WITH ASTM C1193, UNLESS SPECIFIED
OTHERWISE OR RECOMMENDED OTHERWISE BY THE SEALANT
MANUFACTURER.
B. TOOLING: TOOL JOINTS CONCAVE, UNLESS INDICATED OR SPECIFIED
OTHERWISE. FINISH FREE OF AIR POCKETS, FOREIGN EMBEDDED MATTER,
RIDGES, AND SAGS.
C. SCHEDULE:
1) TYPE A: PROVIDE AT INTERIOR JOINTS, UNLESS SPECIFIED OTHERWISE.
2) TYPE PTNS: INSTALL IN FLOOR AND WALL TILE EXPANSION JOINTS, FULL
DEPTH WITHOUT BACKER ROD; COLOR MATCHED TO GROUT IN TILE
LOCATIONS, AS SELECTED BY THE ARCHITECT FOR OTHER LOCATIONS..
3) TYPE S: PROVIDE AT EXTERIOR NON-TRAFFIC JOINTS; BLACK COLOR AT
ALUMINUM FRAMING PERIMETERS; AS DIRECTED AT OTHER LOCATIONS.
4) TYPE SM: PROVIDE AT JOINTS BETWEEN WALLS, COUNTERS OR FLOORS
AND PLUMBING FIXTURES OR TOILET ACCESSORIES, AND AT COUNTER
TO WALL JOINTS WHERE PLUMBING FIXTURES ARE INSTALLED IN THE
COUNTER WHERE SEALANT IS REQUIRED OR INDICATED. USE WHITE
AGAINST WHITE PLUMBING FIXTURES; TRANSLUCENT FOR ALL OTHER
APPLICATIONS.
DIVISION 08 - OPENINGS
081200 - HOLLOW METAL DOOR AND FRAME
1.
GENERAL
A. SECTION INCLUDES: ROLLED STEEL DOOR AND FRAME
2.
PRODUCTS
A. INTERIOR DOORS:
1) FACE SHEET MATERIAL: COLD-ROLLED STEEL, A 1008, 18 GAGE
RECYCLED CONTENT: MINIMUM 35 PERCENT BASED ON SUM OF
PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE OF
PRE-CONSUMER RECYCLED CONTENT.
3) CORE: STIFFENED, AND SOUND DEADENED WITH IMPREGNATED KRAFT
HONEYCOMB CORE COMPLETELY FILLING THE INSIDE OF THE DOORS
AND LAMINATED TO INSIDE FACES OF BOTH PANELS.
4) DOOR HARDWARE REINFORCEMENTS:
A) HINGE REINFORCEMENTS FOR FULL MORTISE HINGES: MINIMUM 7
GAGE.
B) LOCK REINFORCEMENTS: MINIMUM 16 GAGE
2)
C)
5)
FABRICATION:
A) IN ACCORDANCE WITH ASNI A250.8; SEAMLESS; WELDED AND/OR
EPOXY FILLED AT FABRICATOR'S OPTION; GRIND SMOOTH.
B) BEVEL DOOR LATCH EDGES 1/8 INCH IN 2 INCHES.
C) CUT MORTISES FOR BUTTS USING APPROPRIATE TEMPLATES;
081433 - STILE AND RAIL WOOD DOORS
1.
GENERAL
A. SECTION INCLUDES: INSTALLATION OF STILE AND RAIL WOOD DOORS AS
SCHEDULED.
B. SUBMITTALS: REQUIRE AS NECESSARY TO COORDINATE THE WORK.
2.
PRODUCTS
A. STILE AND RAIL TYPE DOORS: FURNISHED BY THE OWNER
3.
EXECUTION
A. INSTALLATION: SPECIFIED IN SECTION 087103.
1.
GENERAL
A. SECTION INCLUDES:
1) CONTRACTOR-FURNISHED HARDWARE FOR SWINGING DOORS (EXCEPT
AS SPECIFIED AS PART OF THE DOOR PACKAGE).
2) DOOR AND HARDWARE INSTALLATION.
B. SUBMITTALS: SUBMIT THE FOLLOWING FOR HARDWARE TO BE FURNISHED
UNDER THIS CONTRACT.
1) PRODUCT DATA
2) HARDWARE SCHEDULE: 4 COPIES WITH DESCRIPTION OF EACH
HARDWARE GROUP. INDICATE THE FOLLOWING
A) TYPE, STYLE, FUNCTION, SIZE, QUANTITY AND FINISH OF HARDWARE
ITEMS.
B) NAME, PART NUMBER AND MANUFACTURE OF EACH ITEM.
C) FASTENINGS AND OTHER PERTINENT INFORMATION.
D) EXPLANATION OF ABBREVIATIONS, SYMBOLS AND CODES
CONTAINED IN SCHEDULE.
E) DOOR AND FRAME SIZES, MATERIALS AND DEGREES OF SWING.
3) WIRING/RISER DIAGRAMS AS APPROPRIATE TO THE WORK.
C. INSTALLER QUALIFICATIONS: INSTALLER: COMPANY WITH QUALIFIED
PERSONNEL, WITH NOT LESS THAN 3 YEARS EXPERIENCE IN INSTALLATION
OF WORK SIMILAR IN SCOPE TO THAT OF THIS PROJECT.
2.
PRODUCTS
A. MANUAL SWINGING DOOR HARDWARE: FURNISHED BY THE OWNER.
B. TYPE: AS SCHEDULED ON THE DRAWINGS
3.
EXECUTION
A. DOOR INSTALLATION
1) MAINTAIN CLEARANCES OF 1/8 INCH AT JAMBS AND HEADS, AND 1/2
INCH FROM BOTTOM OF DOOR TO TOP OF DECORATIVE FLOOR FINISH
OR COVERING, EXCEPT WHERE THRESHOLD IS FURNISHED, PROVIDE
1/4-INCH CLEARANCE FROM BOTTOM OF DOOR TO TOP OF THRESHOLD.
2) INSTALL DOORS TO OPERATE FREELY, BUT NOT LOOSELY, FREE FROM
HINGE BOUND CONDITIONS, STICKING OR BINDING. DO NOT INSTALL IN
FRAMES WHICH WOULD HINDER OPERATION OF DOORS.
3) ENSURE DOORS ARE FREE FROM RATTLING WHEN IN LATCHED
POSITION.
B. FINISH HARDWARE INSTALLATION
1) INSTALL HARDWARE PLUMB, LEVEL AND TRUE TO LINE IN ACCORDANCE
WITH MANUFACTURER'S TEMPLATES, PRINTED INSTRUCTIONS AND
PROJECT CONDITIONS.
2) INSTALL HARDWARE UNITS TO MATCH BUILDING STANDARD MOUNTING
HEIGHTS. FOR NEW CONSTRUCTION, MOUNT HARDWARE AS DETAILED.
WHERE NOT DETAILED, MOUNT IN ACCORDANCE WITH ADA
REQUIREMENTS AND DHI RECOMMENDATIONS.
C. ADJUSTMENT: ADJUST AND CHECK FOR PROPER OPERATION AND
FUNCTION. REPLACE UNITS, WHICH CANNOT BE ADJUSTED TO OPERATE
FREELY AND SMOOTHLY
0844113 - ALUMINUM FRAMED ENTRANCES AND STOREFRONTS
1.
2.
GENERAL
A. SECTION INCLUDES:
1) EXTERIOR AND INTERIOR STICK FRAMED ALUMINUM STOREFRONT
SYSTEMS.
2) ALUMINUM AND GLASS ENTRANCES.
B. PROFILES: FRAMING MEMBER PROFILES, AS INDICATED IN THE DRAWINGS,
INDICATE PROPORTIONS AND INTENT. MINOR VARIATIONS IN PROFILES,
ASSEMBLIES, AND CONNECTIONS WILL BE ACCEPTED, PROVIDED THAT, IN
THE OPINION OF THE ARCHITECT, THEY DO NOT SUBSTANTIALLY ALTER
THE INTENDED APPEARANCE.
C. SUBMITTALS
1) SHOP DRAWINGS: INCLUDE WALL OPENING DIMENSIONS, COMPONENT
DIMENSIONS, TOLERANCES REQUIRED, ANCHORAGES AND FASTENERS,
RELATIONSHIP TO ADJACENT CONSTRUCTION, THRESHOLD
CONFIGURATIONS, INSTALLATION DETAILS, FLASHINGS, AND SEALANT
LOCATIONS.
2) SAMPLES: SUBMIT THREE SAMPLES OF A TYPICAL EXTRUSION
FINISHED WITH SYSTEM AND COLOR PROPOSED FOR THE FINISHED
WORK; 12 INCH MINIMUM LENGTH.
D. GUARANTEE AND WARRANTY
1) MANUFACTURER'S WARRANTY: 3-YEAR WRITTEN WARRANTIES
EXECUTED TO THE OWNER, FROM THE MANUFACTURERS OF THE
STOREFRONT AND ALUMINUM WINDOW SYSTEMS, AGAINST DEFECTS IN
MATERIALS AND WORKMANSHIP.
2) INSTALLER'S GUARANTEE: 3_YEAR WRITTEN GUARANTEE AGAINST
DEFECTS IN INSTALLATION.
PRODUCTS
A. EXISTING SYSTEMS: WHERE FRAMING SYSTEMS ARE INDICATED FOR
RECONFIGURATION OR EXTENSION OF EXISTING, MATCH EXISTING.
B. NEW FRAMING SYSTEMS: ONE OF THE FOLLOWING, OR APPROVED.
FURNISH SCREW-SPLINE, SHEAR BLOCK OR STICK ASSEMBLY AT
CONTRACTOR'S OPTION.
1) KAWNEER NORTH AMERICA
A) EXTERIOR: TRIFAB VERSAGLAZE 451T; 2" X 4-1/2" SECTION;
THERMAL BREAK DESIGN; CENTER GLAZED.
B) INTERIOR: TRIFAB 400; 1-3/4"X4" SECTION, CENTER GLAZED.
2) ARCADIA.
A) EXTERIOR: AG451T; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN;
CENTER GLAZED.
B) INTERIOR: A400; 1-3/4"X4" SECTION, CENTER GLAZED.
3) OLDCASTLE BUILDINGENVELOPE.
A) EXTERIOR: SERIES 3000 THERMAL MULTIPLANE - CENTER SET; 2" X
4-1/2" SECTION; THERMAL BREAK DESIGN; CENTER GLAZED.
B) INTERIOR: FG-1000; 1-3/4"X4" SECTION, CENTER GLAZED.
4) CRL/US ALUMINUM.
A) EXTERIOR: IT451; 2" X 4-1/2" SECTION; THERMAL BREAK DESIGN;
CENTER GLAZED.
B) INTERIOR: SERIES 400; 1-3/4"X4" SECTION, CENTER GLAZED.
C. ENTRY DOORS:
1) EXTERIOR: HEAVY DUTY MEDIUM STILE; 10 INCH NOMINAL BOTTOM
FOLLOWING, OR APPROVED.
A) KAWNEER NORTH AMERICA "350 HEAVY WALL ENTRANCE."
B) ARCADIA "MS362 HD HEAVY DUTY MEDIUM STILE ENTRANCE DOOR."
C) OLDCASTLE BUILDINGENVELOPE "RUGGED MEDIUM STILE."
D) CRL/US ALUMINUM "SERIES 800 DURAFRONT."
2) INTERIOR: NARROW STILE; 10 INCH NOMINAL BOTTOM RAIL; STOPS
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
1.
GENERAL
A. SECTION INCLUDES:
1) VISION LITES FOR DOORS.
2) INTERIOR WINDOW GLAZING.
3) GLAZING FOR EXTERIOR STOREFRONTS.
B. QUALITY ASSURANCE: COMPLY WITH PERTINENT RECOMMENDATIONS IN
THE GANA "MANUAL OF GLAZING."
2.
PRODUCTS
A. CLEAR GLASS: ASTM C1036, TYPE I, CLASS 1(CLEAR), QUALITY Q3 GLAZING
TEMPERED GLASS: ASTM C1048; FULLY TEMPERED.
C. INSULATING GLASS UNITS:
1) EXISTING: WHERE GLAZING IS INDICATED IN RECONFIGURED OR
EXTENDED STOREFRONT SYSTEM (UNLESS ENTRANCE STOREFRONT
GLAZING IS INDICATED TO BE REPLACED WITH NEW), MATCH EXISTING
GLAZING TYPE.
2) NEW STOREFRONT: 2 LAYERS OF 1/4 INCH CLEAR TEMPERED GLASS
WITH 1/2 INCH AIRSPACE; LOW-E COATING TO THE #2 SURFACE; ONE OF
THE FOLLOWING.
B.
A)
VIRACON "VNE63."
D. SETTING BLOCKS: NEOPRENE; 70-90 SHORE A DUROMETER HARDNESS; 4
INCHES LONG X 1/4 HIGH X WIDTH AS REQUIRED FOR APPLICATION
INDICATED.
C)
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SECTION 088000 - GLAZING
B)
APPROVED.
A) KAWNEER NORTH AMERICA "190 STANDARD ENTRANCE."
B) ARCADIA "NS212 SERIES NARROW STILE ENTRANCE DOOR."
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
PROJECT NUMBER: 16-059
055023 - OVERHEAD SUPPORT FRAMING
1.
SUBSTRATE.
VERIFY THAT WORK OF OTHER TRADES HAS PROGRESSED TO THE
POINT WHERE REPLACEMENT FIREPROOFING INSTALLATION CAN
BEGIN.
2) APPLICATION: ALL PATCHING AND REPAIRING OF SPRAYED
REPLACEMENT FIREPROOFING DUE TO REMOVAL AS NECESSARY TO
ACCOMMODATE NEW CONSTRUCTION, AND DAMAGE BY THE OTHER
TRADES, SHALL BE PERFORMED UNDER THIS SECTION.
PREFABRICATED TRIM: AS SCHEDULED; FURNISHED BY OWNER UNLESS
OTHERWISE SCHEDULED.
E. TAMBOUR: AS SCHEDULED.
F. CEDAR: FURNISHED BY THE OWNER
1) MDO (SMOOTH) PLYWOOD: APA RATED, GROUP 1, B-C OR BETTER; MDO
FACE.
G. MEDIUM DENSITY FIBERBOARD (MDF):
1) ANSI A208.2 CLASS MD (MEDIUM DENSITY).
2) MOISTURE RESISTANT MDF: SIERRA PINE LTD. (800 676 3339) "MEDEX";
D.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
3. EXECUTION:
A. INSTALL METAL FABRICATIONS IN ACCURATE LOCATIONS SHOWN. UNLESS
INDICATED OTHERWISE, FABRICATIONS SHALL BE INSTALLED PLUMB AND
LEVEL.
SHEET TITLE
ARCHITECTURAL
SPECIFICATIONS
SHEET NUMBER
AS1.2
SCHEDULE: INDICATED ON THE DRAWINGS.
DIVISION 09 - FINISHES
092200 - LIGHTGAGE METAL SUPPORT FRAMING
1.
2.
GENERAL
A. SECTION INCLUDES:
1) PARTITION FRAMING.
2) STEEL BACKING.
3) CEILING AND SOFFIT FRAMING.
4) FURRING.
B. SYSTEM DESCRIPTION
1) STRUCTURAL DESIGN OF LIGHTGAGE METAL FRAMING SYSTEMS SHALL
BE FURNISHED BY THE CONTRACTOR.
2) PARTITION FRAMING SHALL CONFORM TO THE WIDTHS INDICATED,
UNLESS APPROVED OTHERWISE. PROVIDE THICKER GAGES AND
DECREASED STUD SPACING AS NECESSARY TO MEET THE DESIGN
REQUIREMENTS.
3) DESIGN LOADS:
A) INTERIOR CEILING ASSEMBLIES: 5 PSF UNIFORM LIVE LOAD, PLUS
DEAD LOADS.
B) INTERIOR PARTITIONS: 5 PSF UNIFORM LIVE LATERAL LOAD PLUS
WEIGHT OF WALL MOUNTED EQUIPMENT AND CASEWORK..
C) SEISMIC LOADS: SEISMIC DESIGN CATEGORY D.
4) DEFLECTION REQUIREMENTS:
A) MAXIMUM DEFLECTION OF 1/240 FOR FLEXIBLE FINISH MATERIALS
SUCH AS GYPSUM BOARD.
B) MAXIMUM DEFLECTION OF 1/360 FOR RIGID FINISH MATERIALS SUCH
AS CERAMIC TILE.
C. QUALITY ASSURANCE: UNLESS INDICATED OTHERWISE, PERFORM WORK IN
PRODUCTS
A. NON-LOAD BEARING LIGHT GAGE METAL FRAMING:
1) FURNISH "C" SHAPED STUDS, DEPTHS AS INDICATED; ASTM C645;
GALVANIZED; MINIMUM 25 GAGE (18 MIL).
2) FURNISH U SHAPED TRACKS (RUNNERS), HAT AND "Z" SHAPED FURRING
CHANNELS, AND OTHER SIZES AND SHAPES AS INDICATED ON THE
DRAWINGS, AND REQUIRED BY THE REFERENCED STANDARDS.
3) RECYCLED CONTENT: MINIMUM 10 PERCENT CALCULATED (BASED ON
SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE
OF PRE-CONSUMER) RECYCLED CONTENT.
4) PARTITION HEAD COMPENSATING CHANNEL (NON-FIRE RATED): DESIGN
1.
2.
B)
3.
EXECUTION
A. INTERIOR PARTITION FRAMING
1) RUNNERS:
A) SECURE RUNNERS WITH FASTENERS AT MAXIMUM 24 INCHES OC.
B) TOP RUNNER: SECURE HEAD TRACK TO STRUCTURE WITH
ALLOWANCE FOR STRUCTURAL DEFLECTION.
(1) NON RATED PARTITIONS: USE PROPRIETARY COMPENSATING
CHANNEL OR DEEP LEG TRACK AT CONTRACTOR'S OPTION, AS
NECESSARY TO ACCOMMODATE BUILDING DEFLECTION.
(2) FIRE RATED PARTITIONS: INSTALL PROPRIETARY FIRE RATED
RUNNER AND ACCESSORIES AS NECESSARY TO MEET THE FIRE
RATING REQUIREMENTS INDICATED ON THE DRAWINGS; COMPLY
WITH UL REQUIREMENTS FOR LISTED ASSEMBLY.
C) COORDINATE WITH SECTION 078100 FOR SEQUENCING AND
PATCHING OF FIREPROOFING MATERIALS, AS NECESSARY TO
MAINTAIN FIRE SEPARATION.
2) UNLESS INDICATED OTHERWISE, INSTALL STUDS VERTICALLY AT 24
INCHES O.C., AND NOT MORE THAN 2 INCHES FROM ABUTTING
CONSTRUCTION, AT EACH SIDE OF OPENINGS, AND AT CORNERS.
FIT RUNNERS UNDER AND ABOVE OPENINGS; SECURE INTERMEDIATE
STUDS AT SPACING OF WALL STUDS.
4) BRACE PARTITION FRAMING SYSTEM AND MAKE RIGID.
5) INSTALL DOUBLE STUDS CONTINUOUS FROM FLOOR TO CEILING TRACK
AT THE JAMB OF EACH DOOR FRAME AND CASED OPENING. STUDS
SHALL BE NO LESS THAN 20 GAGE. PROVIDE DIAGONAL STEEL STUD
BRACING TO STRUCTURE AT EACH JAMB AT PARTITIONS WHICH DO NOT
EXTENT TO STRUCTURE.
6) AT NON-LOAD BEARING FULL HEIGHT PARTITIONS SUBJECT TO
COMPRESSION CAUSED BY OVERHEAD STRUCTURAL DEFLECTION, AND
WHERE PROPRIETARY COMPENSATING CHANNEL SYSTEM IS NOT USED,
CUT STUDS 1/2 INCH SHORT FROM FULL HEIGHT. DO NOT RIGIDLY
CONNECT STUD TO TOP RUNNER.
7) STUD BRIDGING: AT INTERIOR PARTITIONS GREATER THAN 4 FEET IN
LENGTH, AND WITH RIGID FACING MATERIAL ON ONE STUD FLANGE
ONLY, PROVIDE 3/4" BRIDGING CHANNELS IN HORIZONTAL ROWS AT A
MAXIMUM OF 5'-0" O.C. FOR THE FULL HEIGHT OF THE PARTITION.
B. BACKING
1) PROVIDE STEEL BACKING WHERE INDICATED. AT THE CONTRACTOR'S
3)
3.
TRIM:
USE LONGEST PRACTICAL LENGTHS, WITH NO PIECE LESS THAN 2 FEET
LONG FOR CONTINUOUS RUNS GREATER THAN 8 FEET. SECURELY
FASTEN AND ALIGN TRIM ENDS AT JOINTS.
2) PLACE CONCEALED FLANGE CORNER BEADS AT ALL EXTERNAL
CORNERS. AT ANGLES OTHER THAN 90 DEGREES, BEND THE FLANGE
TO CONFORM TO THE ANGLE.
3) PLACE CONCEALED FLANGE TYPE L TRIM WHERE GYPSUM BOARD
ABUTS DISSIMILAR MATERIALS.
4) INSTALL CONTROL JOINT TRIM IN GYPSUM BOARD FIELDS WITH
CONTINUOUS RUNS IN EXCESS OF 30 FEET, AND IN LOCATIONS AS
DIRECTED
E. FINISHING:
1) PROVIDE IN ACCORDANCE WITH GA 214.
2) WHERE NECESSARY TO SAND, DO SO WITHOUT DAMAGING THE FACE
OF THE GYPSUM BOARD.
3) FINISH:
A) TYPICAL: GA LEVEL 4.
B) TEXTURED FINISH: SKIM COAT TO TROWEL PATTERN TO MATCH
APPROVED MOCK-UP.
C) SURFACES TO RECEIVED FRP: GA LEVEL 1.
D) SURFACES TO RECEIVE ADHERED TILE: GA LEVEL 0.
3.
EXECUTION
A. EXAMINATION
1) PRIOR TO STARTING WORK, INSPECT INSTALLED WORK OF OTHER
TRADES AND VERIFY THAT SUCH WORK IS COMPLETE TO THE POINT
WHERE WORK OF THIS SECTION MAY PROPERLY COMMENCE.
2) NOTIFY THE ARCHITECT IN WRITING OF CONDITIONS DETRIMENTAL TO
THE PROPER AND TIMELY COMPLETION OF THE WORK.
B. INSTALLATION
1) INSTALL AT WALLS AS INDICATED ON THE DRAWINGS.
2) INSTALL UNITS WITH EDGES FIRMLY SUPPORTED.
3) ATTACH UNITS WITH SCREWS SPACED 6 INCHES ON CENTER ALONG
FRAMING.
4) SPACE BOARDS 1/8 TO 3/16 INCH APART. STAGGER BOARD JOINTS WITH
THOSE OF ADJACENT ROWS. FILL JOINTS BETWEEN GLASS MESH
PANELS WITH BONDING MORTAR, EMBED REINFORCING, COVER OVER
WITH BONDING MORTAR AND TROWEL SMOOTH.
3)
2.
SCHEDULED; WHITE, UNLESS OTHERWISE INDICATED.
B) WALL MOLDINGS: 7/8 OR 1 INCH FLANGE.
2) SEISMIC DESIGN CATEGORIES C, D, E, OR F:
A) EXPOSED T SYSTEM; ARMSTRONG "SEISMIC RX," WIDTH AS
SCHEDULED; WHITE, UNLESS OTHERWISE INDICATED.
B) WALL MOLDINGS: 7/8 OR 1 INCH FLANGE; INCLUDE SEISMIC CLIPS
FOR ATTACHMENT OF GRID MEMBERS; ARMSTRONG "BERC2 2" BEAM
END RETAINING CLIP," OR APPROVED.
B. ACOUSTICAL PANELS: AS SCHEDULED
1) RECYCLED CONTENT: MINIMUM 15 PERCENT CALCULATED (BASED ON
SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE
OF PRE-CONSUMER) RECYCLED CONTENT.
2) TOXICITY/IEQ:
A) FREE FROM ADDED UREA-FORMALDEHYDE.
B) INCLUDE MANUFACTURER'S STANDARD ANTI-MICROBIAL
TREATMENT:
C. METAL PANELS AND TRIM: AS SCHEDULED.
D. ACCESSORIES: FURNISH HANGERS, CLIPS, FASTENERS, HANGER WIRE
AND OTHER ACCESSORIES AS NECESSARY TO COMPLETE THE WORK.
3.
093000 - TILING
1.
2.
3.
GENERAL
A. SECTION INCLUDES:
1) CERAMIC FLOOR AND WALL TILE.
2) WATERPROOF MEMBRANES.
B. SUBMITTALS:
1) PRODUCT DATA: SUBMIT FOR EACH TYPE OF TILE, MORTAR, GROUT,
ADHESIVE, ADDITIVE, ACCESSORY, AND MEMBRANE.
2) SAMPLES:
A) TILE: SUBMIT SAMPLES OF EACH TYPE AND COLOR OF TILE. INCLUDE
REPRESENTATIVE RANGE OF COLORS AND FINISHES TO BE
EXPECTED.
B) GROUT: SUBMIT CURED SAMPLES OF EACH GROUT COLOR.
C) SHOP DRAWINGS: INDICATE FLOOR PLAN WITH PARTITIONS AND
EXISTING CONDITIONS AS APPROPRIATE; SHOW PROPOSED
EXPANSION JOINT LOCATIONS, FLOOR DRAINS, FLOOR SINKS,
RELATIVE ELEVATIONS, AND PITCHES TO DRAIN.
B.
1.
2.
EXPANSION JOINTS:
1) PROVIDE FOR EXPANSION JOINTS AT MAXIMUM 24 FEET O.C.
2) MATCH MORTAR JOINT WIDTH, EXCEPT THAT JOINTS SHALL BE NO LESS
092900 - GYPSUM BOARD
FIELD PERIMETERS. RAKE JOINTS FREE OF SETTING MORTAR.
1.
GENERAL
A. SECTION INCLUDES:
1) GYPSUM BOARD AND ACCESSORIES.
2) TROWEL TEXTURED FINISH.
3) PATCHING AND TREATMENT OF EXISTING WALL SURFACES.
B. QUALITY ASSURANCE:
1) PERFORM WORK IN ACCORDANCE WITH GA 216, UNLESS SPECIFIED
OTHERWISE, OR REQUIRED OTHERWISE TO MEET FIRE RATING
REQUIREMENTS.
2) MOCK-UP: APPLY TROWEL TEXTURED FINISH TO MINIMUM 4 FOOT
SQUARE PIECE OF GYPSUM BOARD, REPRESENTATIVE OF PROPOSED
FINISH WR01.
2.
PRODUCTS:
A. MANUFACTURER: ONE OF THE FOLLOWING.
1) CERTAINTEED CORP.
2) GEORGIA-PACIFIC GYPSUM, LLC.
3) LAFARGE NORTH AMERICA
4) NATIONAL GYPSUM COMPANY
5) TEMPLE-INLAND INC.
6) USG CORP.
B. GYPSUM BOARD:
1) ASTM C1396; 5/8 INCH THICK; TYPE X FOR USE IN FIRE RATED
PARTITIONS; CONTRACTOR'S OPTION AT OTHER LOCATIONS.
2) RECYCLED CONTENT: MINIMUM 9 PERCENT CALCULATED (BASED ON
SUM OF PERCENTAGE OF POST-CONSUMER PLUS 1/2 OF PERCENTAGE
OF PRE-CONSUMER) RECYCLED CONTENT.
C. WATER RESISTANT BOARD: ASTM C1396; 5/8 INCH THICK.
D. INTERIOR GYPSUM TRIM:
1) CONFORM TO GA 216, UNLESS INDICATED OR SPECIFIED OTHERWISE.
2) CONCEALED FLANGE CRIMP-ON OR TAPE-ON TYPE; METAL OR PVC AT
INSTALLATION OF TILE:
INSTALLERS SHALL FOLLOW INSTRUCTION AS OUTLINED IN THE TCNA
HANDBOOK FOR CERAMIC TILE, GLASS AND STONE TILE FOR INSTALLATION.
1) INTERIOR FLOOR APPLICATION - THINSET OVER CONCRETE
SUBSTRATES AND CONCRETE WITH WATERPROOF MEMBRANE.
A) TCNA SYSTEM: F113.
B) INSTALLATION STANDARD: ANSI A108.5.
C) SETTING MATERIALS: THINSET MORTAR; 3/32 INCH MINIMUM
THICKNESS.
D) GROUT: EPOXY.
2) WALL APPLICATION (TILE BASES) - GYPSUM BOARD SUBSTRATE AND
GYPSUM BOARD WITH WATERPROOF MEMBRANE:
A) TCNA SYSTEM: SIMILAR TO W243.
B) INSTALLATION STANDARD: ANSI A108.5.
C) SETTING MATERIALS: THINSET MORTAR.
D) GROUT: EPOXY.
3) WALL APPLICATION - CEMENTITIOUS TILE BACKING BOARD:
A) TCNA SYSTEM: SIMILAR TO W244.
B) INSTALLATION STANDARD: ANSI A108.5.
C) SETTING MATERIALS: THINSET MORTAR.
D) GROUT: EPOXY.
D. GROUTING: COMPLY WITH PROVISIONS OF ANSI A108.10. GROUT ALL
JOINTS, EXCEPT EXPANSION JOINTS. FLOAT JOINTS TO A SLIGHTLY
CONCAVE PROFILE.
C.
095410 - SUSPENDED PANEL CEILINGS
1.
GENERAL
A. SECTION INCLUDES:
1) SUSPENSION SYSTEM
2.
QUALITY ASSURANCE: MATERIALS AND INSTALLATION SYSTEM SHALL BE
USDA APPROVED FOR FOOD PREPARATION AREAS.
PRODUCTS
A. FRP PANEL SYSTEMS: COMPOSITE PANEL CONSISTING OF UNIFORM
FIBERGLASS GLASS FIBERS EMBEDDED IN ORGANIC RESIN; CLASS C FIRE
1)
TYPE:
A)
EXECUTION
A. INSTALL SYSTEM IN ACCORDANCE WITH ASTM C636, IBC 1621.2.5 AND
CISCA 1-2 OR CISCA 3_4 AS APPROPRIATE TO THE SEISMIC DESIGN
CATEGORY, THE MANUFACTURER'S INSTRUCTIONS, AND AS FOLLOWS.
1) INSTALL ADDITIONAL HANGER WIRES AS NECESSARY TO SUPPORT
SUPERIMPOSED LOADS.
2) COORDINATE WITH MECHANICAL, ELECTRICAL, AND FIRE PROTECTION
WORK FOR ACCOMMODATION OF PENETRATING ELEMENTS.
3) SET PANELS INTO CEILING GRID.
A) BORDER UNITS: WHERE PARTIAL PANELS ARE NECESSARY FOR
INSTALLATION AGAINST WALL MOLDINGS, SCRIBE AND CUT PANELS
TO FIT THE OPENINGS; INSTALL EACH PANEL WITH CUT EDGE FULLY
SUPPORTED BY WALL MOLDING.
B) FIELD UNITS: WHERE CUT PANELS ARE NECESSARY TO
ACCOMMODATE FRAMING AT LIGHT FIXTURES, DIFFUSERS, AND
OTHER INTERRUPTIONS IN THE SUSPENSION SYSTEM MODULE,
SCRIBE AND CUT PANELS TO ACCOMMODATE THE FRAMING OR
PENETRATION.
B. CLEAN-UP: REMOVE FINGERPRINTS, SOIL AND BLEMISHES FROM CEILING
MATERIALS. USE CLEANING MATERIALS RECOMMENDED BY THE
MANUFACTURER OF THE CEILING MATERIALS.
097200 - WALL COVERING
1.
3.
GENERAL
A. SECTION INCLUDES: VINYL COMPOSITION TILE FLOORING.
B. SUBMITTALS
1) PRODUCT LITERATURE: INCLUDE DESCRIPTIONS OF PHYSICAL
CHARACTERISTICS AND INSTALLATION INSTRUCTIONS FOR RESILIENT
FLOORING, ADHESIVES, LEVELING COMPOUNDS, AND ACCESSORIES.
2) SAMPLES: 3 FULL SIZE TILES FOR EACH TYPE AND COLOR OF RESILIENT
TILE FLOORING MATERIAL.
3) PRODUCT DATA:
A) FOR EACH TILE TYPE, INDICATE RECYCLED CONTENT; INDICATE
PERCENTAGE OF PRE-CONSUMER AND POST-CONSUMER RECYCLED
CONTENT PER UNIT OF PRODUCT; INCLUDE CERTIFICATION TO RFCI
FLOORSCORE STANDARD.
B) INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS
COMPLIANCE TO VOC REQUIREMENTS FOR FILLERS AND
ADHESIVES.
C. ENVIRONMENTAL REQUIREMENTS
1) MAINTAIN MINIMUM 70 DEGREES F AIR TEMPERATURE AT FLOORING
INSTALLATION AREA FOR THREE DAYS PRIOR TO, DURING, AND FOR 24
HOURS AFTER INSTALLATION.
2) STORE FLOORING MATERIALS IN AREA OF APPLICATION; ALLOW
MATERIALS TO ACCLIMATE TO ENVIRONMENTAL CONDITIONS PRIOR TO
INSTALLATION.
D. EXTRA STOCK: DELIVER 10 PERCENT EXTRA STOCK OF EACH COLOR AND
PATTERN OF FLOOR MATERIAL REQUIRED FOR PROJECT, FOR
MAINTENANCE USE, PROPERLY PACKAGED AND CLEARLY LABELED.
PRODUCTS
A. RESILIENT TILE FLOORING: AS SCHEDULED; CERTIFIED WITH RFCI
FLOORSCORE STANDARD.
B. ACCESSORIES
1) SUBFLOOR FILLER: WHITE PREMIX LATEX FILLER, MIXED WITH WATER
TO PRODUCE A CEMENTITIOUS PASTE.
2) PRIMER TOXICITY/IEQ: WATER-BASED; CLEAR; OF TYPES AS APPROVED
BY RESILIENT FLOORING MANUFACTURER FOR SPECIFIC MATERIAL AND
SUBSTRATES ENCOUNTERED.
3) ADHESIVES:
A) TYPES RECOMMENDED BY RESILIENT FLOORING MANUFACTURERS
FOR SPECIFIC APPLICATION.
B) TOXICITY/IEQ: COMPLY WITH APPLICABLE REGULATIONS
REGARDING TOXIC AND HAZARDOUS MATERIALS, GS_36 FOR
COMMERCIAL ADHESIVE, AND SOUTH COAST AIR QUALITY
MANAGEMENT DISTRICT RULE 1168.
4) TRANSITION STRIPS: VINYL; PROFILE(S) AS INDICATED; COLOR AS
SELECTED BY THE ARCHITECT FROM MANUFACTURER'S STANDARD.
5) ALL OTHER MATERIALS NOT SPECIFICALLY DESCRIBED, BUT REQUIRED
FOR A COMPLETE AND PROPER INSTALLATION OF RESILIENT FLOORING,
SHALL BE ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE
MATERIAL TO WHICH IT IS APPLIED AND SHALL BE SUBJECT TO THE
APPROVAL OF THE ARCHITECT.
2.
PRODUCTS
A. WALL COVERING: TYPES AS SCHEDULED ON THE DRAWINGS; FURNISHED
BY THE OWNER.
B. ADHESIVES: AS RECOMMENDED BY THE WALL COVERING MANUFACTURER
FOR THE APPLICATION. ADHESIVES SHALL MEET THE REQUIREMENTS OF
THE SOUTHERN CALIFORNIA SOUTH COAST AIR QUALITY MANAGEMENT
DISTRICT (SCAQMD) RULE 1168.
3.
EXECUTION
A. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING
HAVE RECEIVED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000.
B. PREPARATION: REMOVE ELECTRICAL OUTLET AND SWITCH PLATES,
MECHANICAL DIFFUSERS, ESCUTCHEONS, REGISTERS, SURFACE
HARDWARE, FITTINGS, AND FASTENINGS PRIOR TO STARTING WORK;
STORE DURING AND REPLACE AFTER COMPLETION OF WORK.
C. INSTALLATION
1) MIX AND APPLY ADHESIVES IN ACCORDANCE WITH THE ADHESIVE
MANUFACTURER'S DIRECTIONS FOR THE TYPE OF MATERIAL BEING
APPLIED.
2) INSTALL WALL COVERING SECURE, SMOOTH, CLEAN, AND WITHOUT
WRINKLES, GAPS OR OVERLAPS.
3) EXTEND WALL COVERING CONTINUOUSLY BEHIND ITEMS WHICH ARE
CLOSE TO BUT NOT TOUCHING WALLS.
4) PROVIDE DOUBLE-CUT SEAMS ON NONMATCH PATTERNS; BUTT SEAMS
ON MATCH PATTERNS.
5) INSTALL WALL COVERING ORIENTED VERTICALLY, UNLESS OTHERWISE
INDICATED.
6) CORNER SEAMS: MAKE NO SEAMS WITHIN 6 INCHES OF AN INSIDE OR
OUTSIDE CORNER, EXCEPT WHERE A COLOR OR PATTERN CHANGE IS
INDICATED. LAP WALL COVERINGS AT INSIDE CORNER SEAMS TO
PREVENT SUBSTRATE SHOW THROUGH.
1.
2.
PREPARATION: INSTALL SUBFLOOR FILLER TO FILL LOW SPOTS, CRACKS,
CONSTRUCTION JOINTS, HOLES AND OTHER DEFECTS, AND AS REQUIRED
TO ADJUST LEVEL TO MEET ADJACENT FINISHES. FEATHER TO MAXIMUM
SLOPE OF 1/8 INCH IN 3 FEET; FLOAT TO SMOOTH, FLAT, HARD SURFACE.
PROHIBIT TRAFFIC OVER FILLER.
C. FLOORING INSTALLATION
1) MIX TILE TO ENSURE SHADE VARIATIONS DO NOT OCCUR WITHIN ANY
ONE AREA.
2) UNLESS INDICATED OTHERWISE, INSTALL FLOORING WITH JOINTS AND
SEAMS PARALLEL TO BUILDING LINES. INSTALL WITH MINIMUM TILE
WIDTH 1/2 FULL SIZE AT ROOM OR AREA PERIMETER.
3) ARRANGE TO SQUARE GRID PATTERN WITH ALL JOINTS ALIGNED.
COLOR: P199 "PEBBLED SURFACE"; "BRIGHT WHITE."
ADHESIVE: "C-551 MARLITE FRP ADHESIVE," UNLESS OTHERWISE
RECOMMENDED BY THE PANEL MANUFACTURER FOR THE SUBSTRATE
INDICATED; VOC MAXIMUM 50 G/L.
C. SEALANT: MANUFACTURER'S STANDARD SILICONE SEALANT; WHITE.
D. TRIM MOLDINGS: MANUFACTURER'S STANDARD PVC; COLOR TO MATCH
PANELS.
1) EDGE (J): M370.
2) DIVISION (H): M365
3) INSIDE CORNER: M350.
4) OUTSIDE CORNER: M360.
2)
3.
3.
EXECUTION
A. EXAMINATION: ENSURE THAT SURFACES TO RECEIVE WALL COVERING
HAVE RECEIVED A COAT OF WALL SIZE AS SPECIFIED IN SECTION 099000.
B. INSTALLATION
1) COORDINATE WITH OTHER TRADES TO ACCOMMODATE ADJACENT
FINISHES.
2) DRY FIT SHEETS INTO PLACE BEFORE APPLYING ADHESIVE.
3) CUT HOLES ACCURATELY TO CONFORM TO THE PENETRATION, AND
OVERSIZED BY 1/16" ALL AROUND.
4) CLEAN SUBSTRATE AND PANEL SURFACES.
5) APPLY ADHESIVE IN ACCORDANCE WITH THE MANUFACTURER'S
PRINTED APPLICATION INSTRUCTIONS.
6) TROWEL APPLY ADHESIVE CONTINUOUSLY OVER SUBSTRATE. BOND
EACH SHEET TO THE SUBSTRATE BY PROGRESSING FROM ONE SIDE TO
THE OTHER TO EXPEL ALL AIR. APPLY PRESSURE UNIFORMLY TO THE
FACE OF THE SHEET BY USING A WIDE HARD RUBBER ROLLER.
7) ALLOW 1/16 INCH EXPANSION SPACE BETWEEN PANELS AND AT ALL
SURROUNDING CONSTRUCTION.
C. REMOVE ADHESIVE FROM FACE OF PANELS USING SOLVENT
RECOMMENDED BY ADHESIVE MANUFACTURER.
097736 - FIBERGLASS REINFORCED PLASTIC PANEL WALL COVERINGS
1.
GENERAL
A. SECTION INCLUDES: FIBERGLASS REINFORCED PLASTIC (FRP) WALL
COVERING PANEL SYSTEM.
B. SUBMITTALS
1) PRODUCT LITERATURE.
2) SAMPLES:
A) EACH TYPE OF JOINT/TRIM PROFILE; MINIMUM 12 INCHES LONG;
B) PROPOSED PANEL; MINIMUM 12 X 12 INCHES
EXECUTION
A. PREPARATION : COORDINATE INSTALLATION WITH THE INSTALLERS OF
ADJACENT AND INTEGRAL CONSTRUCTION TO ALLOW FOR INSTALLATION
OF FRP PANELS PRIOR TO THE INSTALLATION OF ESCUTCHEONS, COVER
PLATES, LOUVER FLANGES, AND OTHER COMPONENTS TO BE INSTALLED
OVER OR THROUGH FRP PANELS.
B. ADHESIVE WALL PANEL INSTALLATION
1) ACCURATELY CUT AND FIT PANELS AROUND OBSTRUCTIONS; SCRIBE
FIT AT EDGES.
2) DO NOT INSTALL PANELS WITH EDGE OR SURFACE DAMAGE. REPLACE
WITH NEW UNDAMAGED MATERIAL, ALL PANELS WHICH BECOME
CHIPPED OR DAMAGED PRIOR TO FINAL ACCEPTANCE.
3) PROVIDE J MOLDING AT ALL EXPOSED EDGES. PROVIDE H MOLDING AT
ALL VERTICAL BUTT JOINTS. H MOLDINGS SHALL NOT BE RUN BEHIND
BASE FINISH MATERIAL. PROVIDE TRIM MOLDINGS AT INSIDE AND
OUTSIDE CORNERS.
4) SEAL ALL JOINTS BETWEEN PANELS AND MOLDINGS, AND BETWEEN FRP
SYSTEM AND ADJACENT CONSTRUCTION.
C. CLEAN-UP: REMOVE SOIL AND BLEMISHES FROM WALL MATERIALS.
099000 - PAINTING
1.
GENERAL
A. SECTION INCLUDES: SITE APPLIED INTERIOR PAINT COATINGS.
B. APPLICATOR QUALIFICATIONS: COMPANY SPECIALIZING IN COMMERCIAL
PAINTING AND FINISHING WITH A MINIMUM OF THREE YEARS DOCUMENTED
EXPERIENCE.
C. MAINTENANCE STOCK: FURNISH OVERAGE OF PAINT MATERIALS EQUAL TO
10 PERCENT MINIMUM OF QUANTITY OF EACH FINISH PAINT SYSTEM
COMPONENT, COLOR AND SHEEN REQUIRED FOR THE WORK, BUT FURNISH
NOT MORE THAN ONE FULL ONE GALLON CANS, NOR LESS THAN TWO FULL
ONE PINT CANS, OF EACH TYPE. OVERRUNS IN EXCESS OF ONE GALLON
MAY BE FURNISHED TO THE OWNER AT THE CONTRACTOR'S OPTION.
OVERAGE SHALL BE TAKEN FROM THE BATCH MIX FURNISHED FOR THE
WORK. OVERAGE SHALL BE FURNISHED IN COMPLETELY FILLED, PROPERLY
LABELED, SEALED CANS.
2.
PRODUCTS
A. INTERIOR LATEX WALL AND CEILING PAINT SYSTEM; COLOR MATCH AS
SCHEDULED.
1) MANUFACTURER: BENJAMIN MOORE PAINT COMPANY
2) GYPSUM BOARD PRIMER: "NATURA INTERIOR WATERBORNE PAINT
PRIMER 511"; ZERO VOC
3) METAL PRIMER (DTM): "IRONCLAD LATEX LOW LUSTRE METAL & WOOD
ENAMEL C363"; MAXIMUM VOC CONTENT 150 G/L.
4) WOOD PRIMER: "IRONCLAD LATEX LOW LUSTRE METAL & WOOD
ENAMEL C363"; MAXIMUM VOC CONTENT 150 G/L.
5) FINISH:
A) EGGSHELL: "NATURA INTERIOR WATERBORNE PAINT EGGSHELL
513"; ZERO VOC
B) SEMI-GLOSS: "NATURA INTERIOR WATERBORNE PAINT SEMI-GLOSS
514"; ZERO VOC
B. INTERIOR TRANSPARENT FINISH SYSTEM.
1) STAIN: AS SCHEDULED.
2) TRANSPARENT FINISH: MINWAX "POLYCRYLIC PROTECTIVE FINISH," OR
APPROVED; SATIN SHEEN UNLESS OTHERWISE INDICATED.
C. ACRYLIC WALL SIZE: BENJAMIN MOORE PAINT COMPANY "MOORE'S
GENERAL
A. SECTION INCLUDES: STAINLESS STEEL SHEET ADHERED DIRECTLY TO THE
WALL.
B. PRODUCT LITERATURE: ADHESIVE.
C. SUBMITTALS: AS NECESSARY TO COORDINATE FABRICATION WITH FIELD
DIMENSIONS.
D. ENVIRONMENTAL CONDITIONS
1) ACCLIMATIZE TO AMBIENT TEMPERATURE (~70 DEGREES F) BEFORE
INSTALLATION.
2) MAINTAIN ADEQUATE VENTILATION AND CONDITIONS TO PREVENT
COMBUSTION OF ADHESIVE FUMES.
PRODUCTS
A. STAINLESS STEEL SHEET PANELS: FURNISHED BY THE OWNER.
B. WATER RESISTANT CONTACT BOND ADHESIVE; MAXIMUM VOC 250 G/L.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
ACCEPTABLE OPTION (SUBJECT TO COMPLIANCE WITH CONTRACT
DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF
COLOR AND CONFORMANCE TO DESIGN INTENT.): CRANE
B.
097243 STAINLESS STEEL WALL COVERING
EXECUTION
A. MOISTURE TESTING OF CONCRETE SLABS: PERFORM ANHYDROUS
CALCIUM CHLORIDE TESTS IN ACCORDANCE WITH ASTM F1869 TO
DETERMINE THE VAPOR EMISSION RATE FROM THE CONCRETE SLAB.
NOTIFY THE ARCHITECT IF TESTS RESULTS SHOW A VAPOR EMISSION RATE
B.
GENERAL
A. SECTION INCLUDES: INSTALLATION OF OWNER FURNISHED WALL
COVERINGS.
B. SUBMITTALS: SUBMIT PRODUCT DATA FOR PROPOSED ADHESIVES AND
ACCESSORIES. INCLUDE MSDS SHEETS OR OTHER EVIDENCE THAT SHOWS
COMPLIANCE TO VOC REQUIREMENTS FOR ADHESIVES.
C. QUALITY CONTROL: WALL COVERING INSTALLER SHALL HAVE MINIMUM OF
3 YEARS EXPERIENCE IN WALL COVERING INSTALLATIONS OF SIMILAR AND
SCOPE.
D. DELIVERY, STORAGE, AND HANDLING: STORE WALL COVERING MATERIALS
FLAT, NOT UPRIGHT, IN A DRY AREA. MAINTAIN TEMPERATURE OF
STORAGE AREA AT A MINIMUM OF 45 DEGREES F., UNLESS A HIGHER
TEMPERATURE IS RECOMMENDED BY WALL COVERING MANUFACTURER.
E. ENVIRONMENTAL CONDITIONS
1) TEMPERATURE:
A) DO NO WALL COVERING WORK UNTIL SURFACES AND MATERIALS
B)
RECOMMENDED BY WALL COVERING MANUFACTURER, FOR 3 DAYS
BEFORE WORK BEGINS.
B) MAINTAIN MINIMUM OR ABOVE TEMPERATURES DURING THE ENTIRE
INSTALLING TIME AND UNTIL ADHESIVES HAVE FULLY DRIED OR
CURED.
2) LIGHTING: DURING INSTALLATION, MAINTAIN MINIMUM LIGHTING LEVEL
OF 15 FOOT-CANDLES ON THE SURFACES TO RECEIVE WALL COVERING.
USE TEMPORARY LIGHTING, IF NECESSARY, TO ATTAIN SPECIFIED
LEVEL.
SECTION 096519 - RESILIENT TILE FLOORING
PRODUCTS
A. TILE: AS SCHEDULED ON THE DRAWINGS.
B. ACCESSORY MATERIALS: AS FOLLOWS, UNLESS OTHERWISE
RECOMMENDED BY THE TILE MANUFACTURER.
1) TILE WATERPROOFING MEMBRANE: ONE OF THE FOLLOWING.
A) NOBLE COMPANY "NOBLESEAL TS."
B) BOSTIK "HYDROMENT ULTRA-SET."
C) MAPEI AMERICAS. "MAPELASTIC SMART.."
D) LATICRETE HYDROBAN
2) THINSET MORTAR: IN ACCORDANCE WITH ANSI A118.4; PORTLAND
CEMENT WITH 100 PERCENT ACRYLIC LATEX ADDITIVE
A) LATICRETE 254 PLATINUM
3) EPOXY GROUT: ONE OF THE FOLLOWING; COLOR MATCH AS
SCHEDULED ON THE DRAWINGS.
A) MAPEI AMERICAS "KERAPOXY."
B) BOSTIK "HYDROMENT COLOR-POXY."
C) LATICRETE INTERNATIONAL INC. "SPCTRALOCK 2000 IG GROUT."
EXECUTION
A. SLAB LEVELING:
1) PRIOR TO INSTALLATION OF THINSET FLOOR TILE, WHERE LOCAL
IRREGULARITIES IN THE SUBSTRATE SURFACE WOULD CAUSE
PUDDLING, PREVENT LEVEL INSTALLATION OF THE TILE, OR INTERRUPT
DRAINAGE PATTERNS, THE SUBSTRATE SHALL BE ADJUSTED AS
NECESSARY. USE THINSET MORTAR OR OTHER FILLER FOR SLAB
LEVELING.
2) WHERE PITCHES TO DRAIN ARE INDICATED, SLOPE FLOORING MINIMUM
PRODUCTS
A. SUSPENSION SYSTEM:
1) SEISMIC DESIGN CATEGORIES A OR B:
C.
A)
1)
GENERAL
A. SECTION INCLUDES: GLASS MESH REINFORCED CEMENT BOARD
SUBSTRATE FOR TILE.
B. SUBMITTALS: PRODUCT DATA.
PRODUCTS
A. BOARD MATERIAL: 1/2 INCH NOMINAL THICKNESS AGGREGATED PORTLAND
CEMENT PANEL, REINFORCED WITH GLASS FIBER MESH; ONE OF THE
FOLLOWING.
1) CUSTOM BUILDING PRODUCTS (SEAL BEACH CA; 800-272-8786)
"WONDERBOARD."
2) FINPAN (HAMILTON OH; 800_833_6444) "UTIL-A-CRETE."
3) USG CORPORATION (CHICAGO, IL; 312-436-4000) "DUROCK."
4) NATIONAL GYPSUM COMPANY (CHARLOTTE NC; 800_628_4662)
"PERMABASE."
B. TAPE FOR GLASS MESH BOARD: OPEN WEAVE GLASS MESH JOINT TAPE,
SELF-ADHESIVE; 2-1/2 INCHES WIDE.
C. FASTENERS: AS RECOMMENDED BY THE BACKER BOARD MANUFACTURER;
THREAD FORMING SELF-DRILLING WAFER HEAD SCREWS; POLYMER
COATED OR ZINC PLATED; USG "DUROCK SCREWS," "ROCK-ON," OR
APPROVED.
D. BONDING MORTAR: THINSET MORTAR, AS SPECIFIED IN SECTION 093000.
EXECUTION
A. INSTALLATION STANDARD: PERFORM WORK IN ACCORDANCE WITH
GYPSUM ASSOCIATION GA-216.
B. INSTALL WATER RESISTANT BOARD WHERE INDICATED AS SUBSTRATE FOR
TILE IN TOILET ROOMS.
C. SCREW FASTEN BOARD TO FRAMING.
UNLESS OTHERWISE INDICATED, INSTALL WITH PATTERN GRAIN
ALTERNATING WITH ADJACENT UNIT TO PRODUCE BASKET WEAVE
PATTERN (WHERE APPROPRIATE).
4) TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR AT DOOR
OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR, AND WHERE
NO THRESHOLD IS INDICATED.
5) INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES WHERE
FLOORING TERMINATES.
PANEL CEILING.
METAL PANEL CEILING AND TRIM
B. QUALITY ASSURANCE: PERFORM NEW WORK AS NECESSARY TO MAINTAIN
COMPLIANCE WITH IBC 1621.2.5, SEISMIC DESIGN CATEGORY D, AND THE
REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES.
2)
D.
092813 - CEMENTITIOUS BACKING BOARDS
A)
PROPRIETARY COMPENSATING CHANNEL SYSTEM, UTILIZING TSN
"VERTICLIP SLD," FIRE TRAK INC. "POSI KLIPS," OR SIMILAR SYSTEM
AT CONTRACTOR'S OPTION.
B. PROPRIETARY CEILING SUSPENSION SYSTEM:
1) MANUFACTURER:
A) BASIS OF DESIGN: CHICAGO METALLIC (LOS ANGELES CA;
800-323-7164).
B) ACCEPTABLE OPTIONS (SUBJECT TO COMPLIANCE WITH CONTRACT
DOCUMENT REQUIREMENTS AND ARCHITECT'S APPROVAL OF
CONFORMANCE TO DESIGN INTENT.):
(1) USG INTERIORS, INC. (CHICAGO, IL; 800-874-4968).
(2) ARMSTRONG (800_207_2321).
2) SUSPENSION SYSTEM: SIMILAR TO SYSTEM 650, OR 670; ASTM C635
HEAVY DUTY CLASSIFICATION.
C. ACCESSORIES:
1) SCREWS: SELF DRILLING; LOW PROFILE HEAD; GALVANIZED.
2) CONCRETE ANCHORS: POWERS FASTENERS "POWDER ACTUATED
FASTENERS," ITW RAMSET "POWDER FASTENERS," HILTI "POWDER
ACTUATED NAILS," OR APPROVED; TYPES AS APPROPRIATE TO THE
WORK.
3) HANGER WIRE: ASTM A641; CLASS 1 ZINC COATING; SOFT TEMPER;
PRESTRETCHED; 12 GAGE.
4) RESILIENT CHANNELS: USG "RC-1," OR APPROVED.
5) BACKING: DIETRICH INDUSTRIES (RENTON WA; 425_251_1497)
"DANBACK FLEXIBLE WOOD BACKING PLATE"; UNTREATED; LENGTH AS
APPROPRIATE TO STUD SPACING.
6) OTHER FRAMING MATERIALS: IN ACCORDANCE WITH ASTM C754.
CONTRACTOR'S OPTION.
JOINT COMPOUND, TAPE, AND FINISHING COMPOUND: ASTM C475; PAPER
TAPE, TYPICAL; SELF-ADHESIVE FIBERGLASS MESH TAPE FOR USE AT
SURFACES TO RECEIVE ADHERED TILE.
F. SCREWS: ASTM C1002.
E.
3.
EXECUTION
A. PREPARATION:
1) MOISTURE CHECK: CHECK FOR EXCESS MOISTURE USING AN
ELECTRONIC MOISTURE METER. DO NOT PAINT MATERIALS WITH
EXCESS MOISTURE LEVELS WHICH WOULD IMPAIR THE BONDING OF
FINISH COATINGS.
2) HARDWARE AND MISCELLANEOUS ITEMS:
A) CAREFULLY REMOVE ELECTRICAL OUTLET AND SWITCH PLATES,
MECHANICAL DIFFUSERS, ESCUTCHEONS, SURFACE HARDWARE,
FITTINGS AND FASTENINGS PRIOR TO STARTING WORK.CAREFULLY
STORE,
B) CLEAN AND REPLACE THESE ITEMS UPON COMPLETION OF WORK IN
EACH AREA.
3) REMOVE DIRT, DUST, GREASE, OIL, MOISTURE, AND OTHER
CONTAMINANTS WHICH WILL IMPAIR THE PROPER ADHESION OF THE
FINISH.
4) MASK ADJACENT SURFACES.
B. APPLICATION REQUIREMENTS
1) UNLESS SPECIFIED OR INDICATED OTHERWISE, FOLLOW PAINT
MANUFACTURER'S LABEL DIRECTIONS FOR GENERAL APPLICATION
PROCEDURES AND COVERAGE RATES.
2) OPAQUE FINISHES:
A) APPLY NUMBER OF COATS SCHEDULED, EXCEPT THAT ADDITIONAL
FINISH COATS SHALL BE APPLIED AS NECESSARY FOR COMPLETE
HIDING OF SUBSTRATE COLORS.
B) APPLY PRIMER COATS UNTINTED. WHERE MORE THAN ONE COAT OF
PAINT IS REQUIRED, TINT EACH SUCCEEDING COAT UP TO THE FINAL
COAT SIMILAR IN TINT, BUT SLIGHTLY LIGHTER IN VALUE (SHADE).
C) SAND LIGHTLY BETWEEN COATS IF NECESSARY TO ACHIEVE
REQUIRED FINISH; SAND BETWEEN ALL COATS APPLIED TO WOOD
SUBSTRATES.
D) ROLLERS FOR APPLICATION AND BACKROLLING OF LATEX PAINTS
SHALL HAVE A NAP OF 3/8 INCH OR LESS.
E) WHERE ROLLER TEXTURE IS SCHEDULED FOR APPLICATION TO
GYPSUM BOARD SURFACES, FINISH COATS MAY BE
ROLLER-APPLIED, OR SPRAY APPLIED AND BACKROLLED AT
CONTRACTOR'S OPTION.
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
PROJECT NUMBER: 16-059
4.
OPTION, PROPRIETARY OR STEEL BACKING PLATES MAY BE
SUBSTITUTED FOR WOOD BLOCKING INDICATED ON DRAWINGS.
2) UNLESS INDICATED OTHERWISE, STEEL BACKING SHALL CONSIST OF
MINIMUM 4 INCH WIDE 16 GAGE STEEL PLATE SCREWED RIGIDLY TO THE
STUDS.
C. CEILING FRAMING
1) CEILING FRAMING SHALL CONSIST OF STUD AND RUNNER FRAMING OR
SUSPENDED FRAMING, UNLESS INDICATED OR SPECIFIED OTHERWISE.
2) SUSPENDED FRAMING SHALL BE SUSPENDED FROM OVERHEAD
STRUCTURAL ELEMENTS ONLY.
3) STUD AND RUNNER FRAMING:
A) SECURE RUNNERS TO STRUCTURE ABOVE WITH FASTENERS AT A
MAXIMUM OF 24 INCHES O.C.. SIZE FASTENERS AND USE
REINFORCEMENTS AS NECESSARY TO SUPPORT THE DEAD LOADS.
B) SPACE STUDS AT 16 INCHES O.C. AT HORIZONTAL LOCATIONS.
4) LIGHTGAGE SUSPENDED FRAMING:
A) INSTALL IN ACCORDANCE WITH ASTM C754, UNLESS INDICATED OR
SPECIFIED OTHERWISE.
B) SPACE CARRYING CHANNELS 4 FEET O.C. WITH SPLICES LAPPED
MINIMUM 12 INCHES.
C) SUPPORT COLD ROLLED CARRYING CHANNELS WITH HANGER
WIRES SPACED AT 4 FEET O.C. LOOP HANGER WIRE AROUND
SUPPORT ELEMENT AND TIGHTLY WRAP AROUND VERTICAL WIRE 3
TIMES; CUT OFF NEATLY.
D) SPACE FURRING CHANNELS 16" O.C. WITH SPLICES LAPPED 12",
MINIMUM AND TIED; CLIP OR SADDLE TIE TO RUNNER CHANNELS
WITH 16-GAGE TIE WIRE.
E) WHERE OVERHEAD OBSTRUCTIONS PREVENT THE REGULAR
SPACING OF HANGERS, PROVIDE SECONDARY CARRYING MEMBERS
FOR INDIRECT SUPPORT OF THE SUSPENSION SYSTEM, OR
REINFORCE THE NEAREST ADJACENT HANGERS AND RELATED
FRAMING COMPONENTS AS NECESSARY TO SPAN THE REQUIRED
DISTANCE.
5) PROPRIETARY SUSPENDED FRAMING: PER MANUFACTURER'S
RECOMMENDATIONS.
6) STABILIZE SUSPENDED CEILING FRAMING AGAINST LATERAL
MOVEMENT BY MEANS OF DIAGONAL BRACING.
7) INSTALL SUPPLEMENTARY HANGER WIRES FOR SUPPORT OF CEILING
MOUNTED EQUIPMENT.
D. TOLERANCES
1) SURFACE PLANE VARIATION: 1/8 INCH IN 10 FEET.
2) POSITION: WITHIN 1/4 INCH OF REQUIRED LOCATIONS.
EXECUTION
A. INSTALL INSULATING GLASS UNITS IN EXTERIOR STOREFRONTS AND
ALUMINUM/GLASS ENTRANCE DOORS.
B. INSTALL CLEAR TEMPERED GLASS IN INTERIOR FRAMES AS INDICATED.
C. SETTING BLOCKS: PLACE SETTING BLOCKS IN FRAMES FOR SUPPORT OF
GLASS. PLACE AT QUARTER POINTS UNLESS APPROVED OTHERWISE.
D. SET GLASS TIGHTLY IN POSITION WITH PROPER CLEARANCES IN
ACCORDANCE WITH THE FRAME MANUFACTURER'S REQUIREMENTS.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
3.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
ARCHITECTURAL
SPECIFICATIONS
SHEET NUMBER
AS1.3
APPROVED.
SIGNS: 6 X 9 INCHES; HIGH IMPACT STYRENE; WHITE ON BLUE
GRAPHICS; GRADE II BRAILLE; FONT MANUFACTURER'S STANDARD;
MINIMUM 5/8 INCH HIGH TEXT AS INDICATED.
D. ILLUMINATED SIGNAGE: PROVIDED BY THE OWNER.
E. FABRICATION: SIGNS SHALL BE FREE OF ROUGH EDGES, IRREGULAR
SURFACES, NON UNIFORM FINISHES, AND SIMILAR IMPERFECTIONS.
2)
D.
E.
F.
G.
H.
099734 - APPLIED CONCRETE FINISHING SYSTEMS
1.
GENERAL
A. SECTION INCLUDES: STAIN AND SEALER FOR INTERIOR SLAB SURFACES.
B. QUALITY ASSURANCE
C. INSTALLER QUALIFICATIONS: FLOORCARE USA
PLEASE CONTACT: BRIAN BRUNNER
FLOORCARE USA, INC.
2236 W. BLUEMOUND ROAD UNIT E.
WAUKESHA, WI 53186
OFFICE: 262-786-0770 X111
FAX: 262-786-5284
WWW.FLOORCARE-USA.COM
D.
PROJECT CONDITIONS
1) MAINTAIN AN AMBIENT TEMPERATURE BETWEEN 50 DEG F AND 90 DEG F
DURING APPLICATION AND FOR AT LEAST 48 HOURS AFTER
APPLICATION.
2) PROVIDE ADEQUATE VENTILATION.
2.
PRODUCTS
A. STAIN AND SEALER SYSTEM:
1) MANUFACTURER: L.M. SCOFIELD COMPANY (LOS ANGELES, CA;
323-720-3000)(DOUGLASVILLE, GA; 770-920-6000)
2) STAIN:
A) STAIN: ONLY AS DIRECTED BY PSW
B) COLOR: COLORS, PROPORTIONS, AND TECHNIQUES AS DIRECTED
BY THE OWNER'S REPRESENTATIVE, TO MATCH OWNER'S SAMPLE
3) SEALER: SELECTSEAL-W; WATERBORNE LOW VOC CLEAR ACRYLIC
POLYURETHANE SEALER; SEMI-GLOSS SHEEN.
3.
EXECUTION
A. EXAMINATION: PRIOR TO APPLICATION OF EACH PRODUCT, VERIFY THAT
SURFACES TO BE COATED ARE WITHIN HUMIDITY AND PH RANGES
REQUIRED BY THE MANUFACTURER OF EACH SYSTEM.
B. PREPARATION
1) CLEAN SURFACES TO RECEIVE STAIN/SEALER AND TOPCOAT, USING
MANUFACTURER'S RECOMMENDED CLEANING COMPOUNDS, AND IN
ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS.
2) MASK OR OTHERWISE PROTECT ADJACENT SURFACES.
C. APPLICATION
1) STAIN AND SEALER SYSTEM:
A) STAIN:
(1) APPLY TO EXPOSED CONCRETE FLOOR SURFACES, AS
SCHEDULED.
(2) SPRAY APPLY; MAINTAIN A WET EDGE.
(3) MULTIPLE COATS (IF REQUIRED): UNLESS OTHERWISE
DIRECTED, ALLOW EACH APPLICATION TO DRY FOR A MINIMUM
3.
EXECUTION:
A. GRAPHICS SHALL BE MOUNTED LEVEL AND PLUMB AND IN ACCURATE
ALIGNMENT.
B. PLAQUES:
1) CLEAN SURFACES AS NECESSARY TO ACCEPT MOUNTING TAPE.
2) USE DOUBLE STICK TAPE FOR MOUNTING UNLESS APPROVED
OTHERWISE.
C. DECALS: ADHERE TO SUBSTRATE FREE OF BUBBLES.
D. COORDINATE WITH OWNERS VENDOR FOR INSTALLATION OF OWNER
FURNISHED SIGNAGE.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
P:
N
312
E
955
R
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SEALER: AFTER STAIN HAS DRIED THOROUGHLY, ROLL APPLY
SEALER IN ACCORDANCE WITH THE MANUFACTURER'S APPLICATION
INSTRUCTIONS. APPLY TWO COATS UNLESS OTHERWISE
RECOMMENDED OR REQUIRED TO MATCH APPROVED MOCK-UP.
D. PROTECTION: PROTECT FLOOR FROM TRAFFIC FOR AT LEAST 48 HOURS
AFTER FINAL APPLICATION OF SEALER.
B)
DIVISION 10 - SPECIALTIES
101400 - SIGNAGE
1.
2.
GENERAL:
A. SECTION INCLUDES:
1) INSTALLATION OF SIGNAGE FURNISHED BY THE OWNER.
2) CODE REQUIRED, INFORMATIONAL AND DIRECTIONAL AT LOCATIONS
INDICATED ON THE DRAWINGS.
B. REGULATORY REQUIREMENTS: SIGNAGE SHALL CONFORM TO THE
REQUIREMENTS OF THE JURISDICTIONAL CODE AUTHORITIES.
PRODUCTS
A. GENERAL: FURNISH SIGNAGE SIMILAR TO DETAILS. FOR CUSTOM SIGNAGE,
FONT SHALL BE OPTIMA, OR APPROVED.
B. DECALS:
1) TYPICAL: PROVIDED BY OWNER.
2) THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED:
PROVIDED UNDER SECTION 087103.
C. HANDICAPPED TOILET ROOM SIGNS:
1) MANUFACTURER: SS GRAPHICS INC (WYANDOTTE MI; 800-513-1695), OR
S
0334
PROJECT NUMBER: 16-059
GYPSUM BOARD - LATEX SYSTEM:
SYSTEM: THREE COATS - FIRST COAT LATEX PRIMER SEALER
(UNTINTED), SECOND AND THIRD COAT LATEX PAINT (OMIT THIRD COAT
AT PREVIOUSLY PAINTED WALLS SUBJECT TO APPROVAL BY THE
ARCHITECT.)
2) SHEEN: ROLLER TEXTURE; SHEEN AS SCHEDULED.
3) APPLICATION:
A) EXCEPT AS OTHERWISE INDICATED, USE ON ALL EXPOSED GYPSUM
BOARD SURFACES INDICATED TO BE PAINTED OR REPAINTED.
B) PROVIDE PRIME COAT ONLY BEHIND PERMANENTLY MOUNTED
MECHANICALLY ANCHORED ITEMS
C) DO NOT APPLY PRIMER OR PAINT COATINGS TO SURFACES TO
RECEIVE WALL COVERING.
GYPSUM BOARD - SURFACES TO RECEIVE WALL COVERING: APPLY ONE
COAT OF ACRYLIC WALL SIZE.
FERROUS METAL AND GALVANIZED - ACRYLIC SYSTEM:
1) SYSTEM: THREE COATS; FIRST COAT ACRYLIC DTM PRIMER (OMIT AT
SHOP PRIMED ITEMS); SECOND AND THIRD COATS LATEX FINISH. THE
PRIMER MAY BE DELETED AT FACTORY PRIMED SURFACES, EXCEPT AS
NECESSARY TO RECOAT DAMAGED OR ABRADED PREPRIMED
SURFACES.
2) SHEEN: SEMI-GLOSS.
3) APPLICATION: INTERIOR FERROUS METAL SURFACES SCHEDULED FOR
PAINT FINISH INCLUDING INTERIOR HOLLOW METAL DOOR AND FRAME
AND ELECTRICAL PANELS.
WOOD - ACRYLIC SYSTEM:
1) SYSTEM: PROVIDE THREE COATS; FIRST COAT WOOD PRIMER; SECOND
AND THIRD COATS LATEX FINISH.
2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES
SCHEDULED FOR PAINT FINISH.
WOOD - ACRYLIC SYSTEM:
1) SYSTEM: UNLESS OTHERWISE SCHEDULED OR DIRECTED, PROVIDE
THREE COATS; FIRST COAT STAIN, SECOND AND THIRD COATES CLEAR
PROTECTIVE FINISH.
2) APPLICATION: INTERIOR WOOD TRIM AND PANEL SURFACES
SCHEDULED FOR STAIN FINISH.
CLEANUP
1) AS THE WORK PROCEEDS AND ON COMPLETION OF THE WORK,
PROMPTLY REMOVE ALL PRIMERS, PAINTS AND FINISHES WHERE
SPILLED, SPLASHED OR SPLATTERED IN A MANNER NOT TO DAMAGE
THE SURFACE FROM WHICH IT IS REMOVED.
2) REMOVE MASKING.
1)
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
C.
SHEET TITLE
ARCHITECTURAL
SPECIFICATIONS
SHEET NUMBER
AS1.4
4-#12 SELF TAPPING SCREWS
ON EACH SIDE - RTU TO CURB
GENERAL STRUCTURAL NOTES
1.
2.
3.
4.
THIS DRAWING SET IS TO BE VIEWED AS A WHOLE AND COORDINATED WITH ARCHITECTURAL,
MECHANICAL, AND OTHER DISCIPLINES. ALL WORK PERTAINING TO A SPECIFIC CONTRACTOR
MAY OR MAY NOT BE SHOWN ON SPECIFIC DRAWING SECTIONS. IT IS EACH SUBCONTRACTOR'S
RESPONSIBILITY TO PREPARE HIS BID FROM A COMPLETE SET OF PLANS.
THE CONTRACTOR SHALL FOLLOW WRITTEN DIMENSIONS ONLY. DO NOT SCALE DRAWINGS.
DIMENSIONS NOT SHOWN ON PLAN TO BE COORDINATED WITH ARCHITECTURAL PLANS.
6.
THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY
DISCREPANCIES BETWEEN CONSTRUCTION DOCUMENTS AND ACTUAL FIELD CONDITIONS.
7.
SEE ARCHITECTURAL PLANS FOR ADDITIONAL DETAILS AND INFORMATION.
8.
ALL ELEVATIONS GIVEN ARE REFERENCED TO FINISHED FLOOR ELEVATIONS AT 100'-0", UNLESS
SHOWN AS USGS ELEVATIONS.
A-A
CURB PER MECH
SHAPED PRESSURE
TREATED BLKG UNDER
MECH CURB
"A"
3/8" BOLT w/ WASHERS AND
LOCK NUTS (MIN 8 TOTAL)
LOAD
2"
MAX
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
BLKG BELOW IF CURB
LANDS ON RIDGE
COPE TOP LEG
OF ANGLE
A
L4x4x1/4" UNDER RTU CURB
TYP - PROVIDE JOIST STRUT
AS REQD - PER TYP JOIST
LOAD STRUT DETAIL
HANGING LOAD
BM OR JOIST
B
OUTLINE OF RTU CURB
S1.0
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
NOTE::
DETAIL APPLIES TO ALL CONCENTRATED
LOADS WHICH EXCEED 100# AND ARE
LOCATED MORE THAN 3" OFF PANEL POINTS
(TOP OR BOTTOM CHORDS)
B-B
10. ALL HOLES THROUGH CONSTRUCTION SHALL BE CORE DRILLED OR SAWCUT.
EA END
1/4
STEEL JOIST
NEW L2x2x1/4" FROM
FRAME TO BOTTOM
CHORD JOIST PANEL
POINT (SEE TYPICAL JOIST
LOAD STRUT DETAIL)
C
Wells
ILLINOIS DESIGN FIRM # 184.006688
"A"
3/16
B
A
R
4 0 4 S.
WHERE GENERAL NOTES OR TYPICAL DETAILS CONTRADICT INFORMATION PROVIDED IN
BUILDING SECTIONS, THE BUILDING SECTIONS TAKE PRECEDENCE.
11. WHERE INFORMATION PROVIDED IN THESE STRUCTURAL DRAWINGS CONTRADICTS
INFORMATION PROVIDED IN BUILDING SPECIFICATIONS, THE SPECIFICATIONS SHALL TAKE
PRECEDENCE.
WHERE DIM "A" IS EQUAL
TO OR GREATER THAN 3"
FIELD INSTALL L2x2x1/4" EA
SIDE OF JOIST AS SHOWN
3/16
A
L3x3x1/4" AS REQUIRED
TO FRAME OPENINGS
THE STRUCTURE SHALL BE ADEQUATELY BRACED AND SHORED DURING ERECTION AGAINST
WIND AND ERECTION LOADS. STRUCTURAL MEMBERS ARE DESIGNED FOR "IN-PLACE" LOADS
ONLY.
THE GENERAL CONTRACTOR SHALL VERIFY ALL OPENING SIZES, PAD SIZES, AND LOCATIONS
WITH THE RESPECTIVE CONTRACTORS.
A
L4x4x1/4" UNDER RTU
CURB (OMIT WHEN CURB
IS WITHIN 2" OF JOIST)
ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
SHALL APPLY AT ANY SIMILAR SITUATION ELSEWHERE ON THE JOB, EXCEPT WHERE A
DIFFERENT DETAIL OR SECTION IS SHOWN.
5.
9.
BEAM OR JOIST (TYP)
St. Louis - Montreal
(E) STEEL JOIST
(E) RTU OPENING
SUPPORT FRAMING
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
RTU SUPPORTS & OPENINGS
B
N.T.S.
S1.0
mechanical
electrical
plumbing
fire protection
structural
RTU FRAMING DETAIL
N.T.S.
D
ALL DIMENSIONS AND ELEVATIONS TO EXISTING CONSTRUCTION ARE FOR REFERENCE
ONLY. FIELD VERIFY DIMENSIONS AND ELEVATIONS PRIOR TO PREPARING SHOP
DRAWINGS, FABRICATING MEMBERS (STRUCTURAL ITEMS), AND INSTALLATION.
2.
ALL HOLES THROUGH EXISTING CONSTRUCTION SHALL BE CORE DRILLED OR SAWCUT. DO
NOT CUT ANY REINFORCING STEEL WHILE DRILLING INTO EXISTING CONCRETE. DO NOT
TORCH CUT.
3.
PRIOR TO SUBMITTING ANY SHOP DRAWINGS, PROVIDE CERTIFICATION FROM LAND
SURVEYOR REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED THAT
DIMENSIONS BETWEEN NEW CONSTRUCTION AND EXISTING CONSTRUCTION HAVE BEEN
SURVEYED AND FORWARDED TO SHOP DRAWING DETAILERS.
4.
PRIOR TO PREPARING SHOP DRAWINGS, EXPOSE ALL FOUNDATIONS AND BUILDING
FRAMING IN THE VICINITY OF NEW CONSTRUCTION AND SUBMIT LAYOUT TO ENGINEER OF
RECORD.
5.
NOTIFY STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND STRUCTURAL DRAWINGS.
6.
FOR ALL EXISTING CONSTRUCTION: DUE TO LIMITED OBSERVATION, OR NOT BEING ABLE
TO VISIT THE EXISTING BUILDING DURING THE PREPERATION OF THESE DOCUMENTS,
ÆDIFICA CASE ENGINEERING HAS ASSUMED THE EXISTING STRUCTURE IS IN LIKE-NEW
CONDITION WITH NO CORROSION, DETERIORATION, OR DAMAGE AND WAS CONSTRUCTED
PER ANY ORIGINAL CONSTRUCTION DOCUMENTS PROVIDED (IF ANY EXIST). CONTRACTOR
SHALL VERIFY THESE ASSUMPTIONS TO THE BEST OF THEIR ABILITY AND NOTIFY THE
ENGINEER OF ANY CONCERNS, ISSUES OR DISCREPANCIES.
(E) JOISTS
L4x4x1/4"
L4X4X1/4"
BOLTS & HANGER
ROD BY OTHERS
HANGER RODS BY OTHERS
BOLTS BY
OTHERS
C
S1.0
HANGER ROD DETAIL
D
3/16
HANGER ROD DETAIL
D
S1.0
N.T.S.
N.T.S.
B
C
SPECIAL INSPECTIONS
1.
3/16
ISSUE DATE
REFER TO THE "STATEMENT OF SPECIAL INSPECTIONS" FOR THE LIST OF ELEMENTS OF
CONSTRUCTION THAT SHALL REQUIRE SPECIAL INSPECTION PER IBC CODE SECTION 1704.
THE OWNER SHALL EMPLOY A SPECIAL INSPECTION AGENCY APPROVED BY THE
STRUCTURAL ENGINEER OF RECORD PRIOR TO THE START OF WORK. COPIES OF ALL
INSPECTION REPORTS SHALL BE SUBMITTED TO THE ARCHITECT OF RECORD,
STRUCTURAL ENGINEER OF RECORD, AND BUILDING INSPECTOR IN A TIMELY MANNER.
2.
THE SPECIAL INSPECTIONS IDENTIFIED ON THE PLANS ARE IN ADDITION TO, AND NOT A
SUBSTITUTE FOR, THOSE INSPECTIONS REQUIRED TO BE PERFORMED BY A BUILDING
INSPECTOR.
3.
CONTINUOUS INSPECTION SHALL BE PROVIDED DURING THE PERFORMANCE OF WORK
REQUIRING SPECIAL INSPECTION, UNLESS OTHERWISE NOTED. WHEN WORK IN MORE
THAN ONE CATEGORY OF WORK REQUIRING SPECIAL INSPECTION IS TO BE PERFORMED
SIMULTANEOUSLY, OR THE GEOGRAPHIC LOCATION OF THE WORK IS SUCH THAT IT
CANNOT BE CONTINUOUSLY OBSERVED, IT SHALL BE THE RESPONSIBILITY OF THE AGENT
TO EMPLOY A SUFFICIENT NUMBER OF SPECIAL INSPECTORS TO ASSURE THAT ALL WORK
IS CONTINUOUSLY INSPECTED IN ACCORDANCE WITH THOSE PROVISIONS.
1704.3
STEEL CONSTRUCTION:
DOCUMENTATION: MATERIAL VERIFICIATION OF STRUCTURAL STEEL
(IDENTIFICATION MARKINGS TO CONFORM TO ASTM A6 OR ASTM A568,
AND MANUFACTURER'S CERTIFIED MILL TEST REPORTS); MATERIAL
VERIFICATION OF THE WELD FILLER MATERIALS (IDENTIFICATION MARKING
TO CONFORM TO AWS STANDARDS; MANUFACTURER'S CERTIFICATE OF
COMPLIANCE REQUIRED). CONTINUOUS INSPECTIONS: COMPLETE AND
PARTIAL PENETRATION GROOVE WELDS; MULTI-PASS FILLET WELDS;
SINGLE-PASS FILLET WELDS GREATER THAN 5/16" ROOT. PERIODIC
INSPECTIONS: SINGLE-PASS FILLET WELDS 5/16" ROOT OR LESS;
INSPECTION OF STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH
APPROVED CONSTRUCTION DOCUMENTS (DETAILS SUCH AS BRACING
AND STIFFENING, MEMBER LOCATIONS, AND APPLICATION OF JOINT
DETAILS AT EACH CONNECTION).
DATE
04-26-2016
05-23-2016
3
T-RP
600#
(E) 20KCS3 - F.V.
(E) 12KCS3 - F.V.
(E) 22KCS2 - F.V.
RTU-2
1608#
DESIGN
STRENGTH
(E) 12KCS3 - F.V.
SEE
STRUCTURAL
STEEL NOTES
(E) 22KCS2 - F.V.
(E) 12KCS3 - F.V.
(E) 20KCS3 - F.V.
RTU-1
1608#
(E) 20KCS3 - F.V.
(E) 20KCS3 - F.V.
(E) 36VG6N10.0K - F.V.
DESCRIPTION OF TYPE OF INSPECTION
REQUIRED, LOCATION, REMARKS, ET CETERA
(E) 20KCS3 - F.V.
(E) 12KCS3 - F.V.
(E) 36VG6N8.0K - F.V.
IBC
REF
ISSUE
DD SET
95% SET
(E) 12KCS3 - F.V.
STATEMENT OF SPECIAL INSPECTIONS
PROJECT NUMBER: 16-059
1.
S1.0
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
(E) JOISTS
EXISTING CONSTRUCTION NOTES
CEILING MOUNTED
TRANSFORMERS HUNG
PER HANGER ROD
DETAIL C & D, TYP
(E) 22KCS2 - F.V.
RTU OPENING PER RTU
OPENING DETAILS A & B,
TYP
T-LP
600#
3.4
(E) 22KCS2 - F.V.
SHEET TITLE
ROOF FRAMING
PLAN & GENERAL
NOTES
(E) 22KCS2 - F.V.
SHEET NUMBER
1
S1.0
(E) PARTIAL ROOF FRAMING PLAN
SCALE: 1/4" = 1'-0"
S1.0
DESCRIPTION
SUPPLY DIFFUSER
RETURN GRILLE
EXHAUST GRILLE
T
S
H
THERMOSTAT / SENSOR / HUMIDISTAT
RECTANGULAR OR ROUND SUPPLY OR
RETURN DUCT (AS NOTED)
MANUAL BALANCE DAMPER
ROOFTOP UNITS
ROOFTOP UNITS SHALL BE FURNISHED BY PSW AND INSTALLED BY CONTRACTOR.
FILTERS
PROVIDE THREE (3) SETS OF PLEATED DISPOSABLE FILTERS. USE ONE SET UNTIL COMPLETION
OF CONSTRUCTION. INSTALL ONE SET AT COMPLETION OF CONSTRUCTION AND DELIVER ONE
SET OF FILTERS TO POTBELLY LABELED TO DENOTE THEIR RESPECTIVE AIR HANDLING UNIT.
FILTERS TO BE FARR, OR SIMILAR.
EXHAUST FANS
PROVIDED TO THE SITE BY VENDOR. THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR
COORDINATING DISCHARGE LOCATION WITH NEW AND EXISTING VENTS AND INTAKES,
PROVIDING COMPLETE INSTALLATION INCLUDING CURBS, BACKDRAFT, DAMPER AND
DUCTWORK FROM RESTROOM GRILLE TO UNIT AND NECESSARY ACCESSORIES, AND
PROVIDING WARRANTY. EXHAUST FAN(S) TO BE OPERATED ``IN CONJUNCTION WITH ROOFTOP
UNIT(S). ROUTE FAN WIRING VIA FAN CONTROL RELAY TO BE INTERLOCKED WITH
PROGRAMMABLE THERMOSTAT. PROVIDE CONTROL RELAY (HONEYWELL R8222 OR
EQUIVALENT) AND 24VAC CONTROL POWER SUPPLY WITH OVERLOAD PROTECTION. INSTALL
POWER SUPPLY (GENSCO #MAR24020XFMR OR EQ) AND FAN CONTROL RELAY ADJACENT TO
ONE ANOTHER IN ACCESSIBLE CEILING SPACE AND EXTEND LOW VOLTAGE WIRING BETWEEN
AUXILIARY RELAY PROVIDED WITH PROGRAMMABLE THERMOSTAT AND FAN CONTROL RELAY.
COORDINATE ALL REQUIREMENTS WITH MECHANICAL CONTRACTOR.
AIR CURTAINS
AIR CURTAINS, WHEN REQUIRED, SHALL BE FURNISHED AND INSTALLED BY THE GENERAL
CONTRACTOR. COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF POWER
CONNECTION.
RECTANGULAR TAKE-OFF FROM
RECTANGULAR DUCT WITH BALANCE
DAMPER
B.O.D.
DAMPER CONTROL
CONTRACTOR TO ENSURE THAT ALL ELECTRICAL CONNECTIONS TO MECHANICAL DAMPERS
ARE CONNECTED.
AIR DEVICE DESIGNATION
SEE SHEET M3.0
EQUIPMENT DESIGNATION
SEE SHEET M3.0
THIS CONTRACTOR SHALL CAREFULLY REVIEW WORK LETTER TO DETERMINE SCOPE OF
WORK. THIS CONTRACTOR SHALL PROVIDE ALL MATERIALS AS NECESSARY TO MAKE
MODIFICATIONS TO LANDLORD PROVIDED SYSTEM.
2.
THIS CONTRACTOR SHALL MODIFY EXISTING UPRIGHT SPRINKLER HEAD IN DROP
CEILING(PLASTER) LOCATIONS TO FULLY RECESSED SPRINKLER HEADS. RELOCATE
UPRIGHT HEADS IN OPEN CEILING AREA TO MAINTAIN FULL AREA COVERAGE.
3.
THIS CONTRACTOR SHALL PROVIDE PERMITTING FOR FINAL HYDRAULIC CALCULATIONS
AND HEAD LOCATIONS BASED UPON FINAL DESIGN BY CONTRACTOR AND SUBMIT TO
LOCAL OR STATE BUILDING DEPARTMENT AS REQUIRED FOR APPROVAL.
4.
ALL WORK SHALL BE IN STRICT ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL
CODES AND ORDINANCES.
DUCT SEALANT
SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH A NON-HARDENING, NONMIGRATING
MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR
SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS, JOINTS
AROUND SPIN-IN FITTINGS AND FASTENING SCREWS WITH MASTIC.
5.
SPRINKLER PIPING SHALL BE ROUTED TO AVOID CONFLICTS WITH NEW AND EXISTING
DUCTWORK, PIPING CONDUITS AND LIGHTING LAYOUT.
6.
SPRINKLER CONTRACTOR SHALL OBTAIN DUCTWORK SHOP DRAWING FROM HVAC
CONTRACTOR AND COORDINATE ROUTING OF SPRINKLER PIPING. ANY RELOCATION
REQUIRED BY SPRINKLER CONTRACTOR'S FAILURE TO COORDINATE SHALL BE DONE AT
NO EXTRA COST OR DELAY TO THE OWNER. GENERAL CONTRACTOR TO COORDINATE.
7.
FINAL CONSTRUCTION DOCUMENTS, HYDRAULIC CALCULATIONS AND PERMITTING
SHALL BE BY THE SPRINKLER CONTRACTOR.
8.
IF REQUIRED: INSTALL INSPECTOR TEST CONNECTIONS PIPED TO FUNNEL DRAIN OR
MOP SINK.
9.
ONLY ONE CONNECTION SHALL BE MADE TO MALL SPRINKLER MAIN. FIELD VERIFY
EXACT LOCATION.
10.
IF REQUIRED: TENANT SPRINKLER SYSTEM SHUT-OFF VALVE AND VALVE TAMPER
SWITCH TO FURNISHED AND INSTALLED BY SPRINKLER CONTRACTOR.
11.
SPRINKLER CONTRACTOR SHALL PERFORM ALL WORK PER LANDLORD'S CRITERIA.
12.
ALL WORK TO BE APPROVED BY LOCAL FIRE DEPARTMENT. SUBMIT SHOP DRAWINGS
FOR APPROVAL TO ENGINEER, TENANT, AND LOCAL FIRE DEPARTMENT.
13.
ALL PERMITS FEES ETC. BY CONTRACTOR.
14.
A FIRE PROTECTION ENGINEER TO PREPARE SET OF CERTIFIED STAMPED SHOP
DRAWINGS OF DESIGN.
15.
ALL SPRINKLER HEADS TO BE QUICK RESPONSE TYPE.
16.
PROVIDE METAL CAGE OVER ALL SPRINKLERS IN COOLER / FREEZER.
RECESSED/CONCEALED SPRINKLER HEAD (NEW)
UPRIGHT SPRINKLER HEAD (NEW)
SPLITTER DAMPER
UPRIGHT SPRINKLER HEAD (ETR)
UCD
UNDERCUT DOOR
MD
MOTORIZED DAMPER
SPRINKLER HEAD WITH CAGE
THERMOSTAT:
CONSTRUCTION AND BIDDING NOTES:
1.
THE HVAC CONTRACTOR SHALL INSTALL HVAC SYSTEMS AS SHOWN, NOTED AND
SPECIFIED. EQUIPMENT MAY NOT BE SUBSTITUTED UNLESS WRITTEN APPROVAL BY
THE ARCHITECT, ENGINEER, OR OWNER'S REPRESENTATIVE IS OBTAINED. ANY
CHANGES TO THE DUCTWORK LAYOUT WILL NECESSITATE SUBMISSION OF SHEET
METAL SHOP DRAWINGS FOR ENGINEER'S REVIEW. ANY UNAUTHORIZED CHANGES WILL
BE REMOVED AT CONTRACTOR'S EXPENSE, IF DEEMED NECESSARY BY ARCHITECT,
ENGINEER, OR OWNER'S REPRESENTATIVE.
2.
THE HVAC CONTRACTOR SHALL COORDINATE DUCTWORK INSTALLATION WITH
ARCHITECT/OWNER'S REPRESENTATIVE IN FIELD AND OTHER TRADES. SEE
ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND HEIGHTS.
3.
ALL DUCTWORK AND PIPING SHALL BE ROUTED ABOVE THE SUSPENDED CEILING SPACE
UNLESS OTHERWISE NOTED ON THE PLANS.
4.
ALL OUTSIDE AIR INTAKES SHALL BE A MINIMUM OF 15'-0'' AWAY FROM EXHAUST
DISCHARGE OPENINGS AND PLUMBING VENT STACKS, AND MINIMUM 10' ABOVE GRADE.
5.
WHEREVER FOUNDATION WALLS, OUTSIDE WALLS, ROOFS, ETC. ARE CUT FOR
INSTALLATION OF SYSTEMS, THEY SHALL BE PATCHED TO MATCH EXISTING
CONSTRUCTION AND SEALED WEATHER TIGHT. WORK SHALL BE PERFORMED BY
CRAFTSMEN SKILLED IN THEIR RESPECTIVE TRADES.
7.
THE MECHANICAL SYSTEMS SHALL BE COMPLETE WITH ALL NECESSARY
APPURTENANCES FOR A COMPLETE OPERATING SYSTEM.
8.
AN INDEPENDENT AIR BALANCE CONTRACTOR SHALL ACCURATELY BALANCE THE AIR
SYSTEMS TO PROVIDE AIR INDICATED ON THE DRAWINGS AND IN THIS SPECIFICATION.
OPERATE AUTOMATIC CONTROLS SYSTEM AND VERIFY SET POINTS. A NEBB OR AABE
CERTIFIED SUPERVISOR SHALL BE IN CHARGE OF WORK. SUBMIT TWO (2) COPIES OF
THE BALANCE REPORT TO THE ENGINEER FOR APPROVAL. INCLUDE A COPY OF THE
BALANCE REPORT AS APPROVED BY THE ENGINEER WITH APPLICATION FOR FINAL
CONTRACT PAYMENT.
THIS CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW
CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR
SHALL SUBMIT SAID WORKLETTER AS EVIDENCE OF HAVING REVIEWED CONTRACTORS
RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE
WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF
THE PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE.
SCOPE
THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE
AND FULLY OPERATIONAL MECHANICAL SYSTEM. THE CONTRACTOR SHALL FURNISH
ALL LABOR, MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OF THE
MECHANICAL WORK.
11.
SITE EXAMINATION
THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT,
DUCTWORK, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN
HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE MECHANICAL WORK.
12.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ARL,
ASME, ASTM, UL, NEMA, ANSI, SMACNA, ASHRAE, NFPA, AS APPLICABLE TO EACH
INDIVIDUAL UNIT OR ASSEMBLY.
13.
CORE-DRILL OR SAW-CUT EXISTING WALLS, ROOF, ETC. AS REQUIRED FOR PIPING OR
DUCTWORK AND FIRE-STOP OPENING AROUND PIPE OR DUCTWORK. VERIFY LOCATION
OF STRUCTURAL BEAMS, JOISTS, ETC. BEFORE DRILLING OR CUTTING. NOTIFY
ARCHITECT OF ANY DISCREPANCIES.
6.
9.
10.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE
AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE
DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST
STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE
REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST TO POTBELLY.
1.
PERMITS AND FEES
THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND
INSPECTIONS NECESSARY TO COMPLETE THE MECHANICAL WORK.
2.
WARRANTY
THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF
DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE
DATE OF FINAL ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY
DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER
EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND
WORKMANSHIP.
CONTROL WIRING
THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT
NECESSARY FOR THE COMPLETE AND PROPER OPERATING TEMPERATURE CONTROL SYSTEM.
THERMOSTAT
THERMOSTAT(S) SHALL BE PROGRAMMABLE ZONE SENSOR, ITEM #KT7351F2127. (1) TO BE
PROVIDED PER HVAC UNIT. MULTISTAGE SEVEN DAY PROGRAMMABLE THERMOSTAT.
REMOTE SENSOR(S) SHALL BE HONEYWELL, ITEM #TR21-A.(2) PER HVAC UNIT.
IF PSW IS PROVIDING THE HVAC UNITS, TRANE IS TO COORDINATE AND SHIP THE
THERMOSTAT/SENSORS AND G.C. IS TO INSTALL. IF PSW IS NOT PROVIDING THE HVAC UNITS,
THE G.C. WILL PURCHASE, SUPPLY AND INSTALL THE THERMOSTAT/SENSORS. ONE
THERMOSTAT AND TWO REMOTE SENSORS TO BE PROVIDED FOR EACH HVAC UNIT. MOUNT
THERMOSTAT(S) INSIDE MANAGERS DESK CUBBY AREA UNLESS OTHERWISE NOTED.
MECHANICAL CONTRACTOR TO PROVIDE THERMOSTAT IDENTIFICATION WITH 81" HIGH WHITE
LETTERS ON KELLY GREEN OR BLACK PHENOLIC LABELS BACKGROUND, I.E. "AC-1 : CUSTOMER
AREA" AND "AC-2 : WORK AREA". REFER TO THERMOSTAT SETUP INSTRUCTIONS BELOW FOR
ADDITIONAL REQUIREMENTS.
THERMOSTAT SETUP INSTRUCTIONS
PROVIDE THE FOLLOWING SETUP AND PROGRAMMING ON THE THERMOSTAT:
1. INSTALL PER MANUFACTURER'S IOM.
2. SET DIP SWITCHES AND JUMPERS AS FOLLOWS:
A) DEGREES F DISPLAY
B) 12 HOUR CLOCK
C) CONTINUOUS FAN OPERATION IN OCCUPIED MODE
D) DISABLE KEYBOARD PROGRAMMING
E) CUT JUMPER IF UNIT IS A HEAT PUMP
3. SET CLOCK AND DAY.
4. SET TO DISPLAY CURRENT TEMPERATURE.
5. START TIMES OF UNITS SHOULD BE STAGGERED IN 15 MINUTE INTERVALS TO AVOID
HIGH SPIKE USAGE, WHICH RESULTS IN A HIGHER KW CHARG TO US BY UTILITY COMPANY.
STANDARD SET POINT SHOULD BE 6AM & 6:15 AM FOR NON-BREAKFAST LOCATIONS.
BREAKFAST LOCATIONS SHOULD HAVE START TIMES OF 5AM & 5:15AM. SET UNOCCUPIED
START TIME AT 1 HOUR AFTER CLOSING. VERIFY HOURS WITH STORE MANAGER OR
CONSTRUCTION MANAGER. THESE SET POINTSCAN BE SET AT THE SAME TIME FRAME. NO
NEED TO STAGGER.
6. SETPOINTS SHALL BE AS FOLLOWS:
OCCUPIED
UNOCCUPIED
HEATING
68deg F
60deg F
COOLING
70deg F
85deg F
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
R
4 0 4 S.
THERMAL INSULATION
PROVIDE EXTERNAL THERMAL INSULATION WITH AN INTEGRAL VAPOR BARRIER FACING OF
SUFFICIENT THICKNESS TO MEET LOCAL ENERGY CODE REQUIREMENTS. PROVIDE INSULATION
ON EXHAUST AND OUTSIDE AIR DUCTS, AND ON CONCEALED PORTIONS OF SUPPLY AND
RETURN AIR DUCTS. DO NOT INSULATE EXPOSED DUCTWORK AND PORTIONS OF DUCTWORK
THAT ARE INTERNALLY LINED. THERMAL INSULATION TO COMPLY WITH AN NFPA FLAME
SPREAD OF 25 OR LESS, AND SMOKE DEVELOPED NO GREATER THAN 50.
BOTTOM OF DUCT
1.
A
GRILLES, REGISTERS & DIFFUSERS
GRILLES, REGISTERS AND DIFFUSERS SHALL BE MANUFACTURED BY TITUS AND SHALL BE GC
SUPPLIED (UON). DIFFUSERS IN METAL PANEL CEILING TO BE ORDERED IN SILVER MILL FINISH.
DIFFUSERS SHALL BE INSTALLED AS INDICATED ON THE DRAWINGS AND SCHEDULES. THE
MECHANICAL CONTRACTOR SHALL PROVIDE ALL MISCELLANEOUS ITEMS NECESSARY FOR A
COMPLETE AND PROPER INSTALLATION IN THE TYPE OF CEILING AND WALLS USED IN THIS
PROJECT.
CFM
DESIGNATION
NUMBER
ACOUSTICAL DUCT LINER
UNLESS OTHERWISE INDICATED ON THE PLANS, PROVIDE MINIMUM OF R-5.6 GLASS FIBER
ACOUSTICAL DUCT LINER ON SUPPLY AND RETURN DUCTWORK WITHIN 10 FEET OF THE
DISCHARGE AND INTAKE OF AIR HANDLING UNITS. INCREASE DUCT SIZED INDICATED ON PLANS
AS NEEDED IN EACH DIMENSION TO ACCOMMODATE LINER. LINER SHALL BE FASTENED TO
DUCT WITH MECHANICAL LINER FASTENERS IN ACCORDANCE WITH SMAGNA.
DAMPERS
PROVIDE OPPOSED-BLADE, MULTI-LEAF VOLUME CONTROL DAMPERS WHERE INDICATED ON
DRAWINGS AND AT POINTS ON LOW PRESSURE SUPPLY, RETURN AND EXHAUST DUCTS
WHERE BRANCHES ARE TAKEN FROM LARGER DUCTS. PROVIDE UL LISTED AND FIRE/SMOKE
DAMPERS WHERE REQUIRED AND IN ACCORDANCE WITH NFPA AND LOCAL CODES. PROVIDE
CONVENIENTLY LOCATED ACCESS DOORS OF AMPLE SIZE AND QUANTITY FOR SERVICING THE
DAMPERS. INSTALL PER UL GUIDELINES.
TURNING VANES
EQUIPMENT
TYPE
SHEETMETAL DUCTWORK
ALL DUCTWORK TO BE RIGID SHEET METAL CONSTRUCTED FROM GALVANIZED SHEET STEEL IN
ACCORDANCE WITH SMACNA LOW VELOCITY DUCT CONSTRUCTION STANDARDS. FIBERGLASS
DUCTBOARD IS NOT ALLOWED. ALL EXPOSED DUCTWORK TO BE ROUND, SPIRAL, OR RECTANGULAR
LOCK-SEAM TYPE, AS SHOWN ON HVAC PLAN SHEET M2.0. ASSEMBLE AND INSTALL DUCTWORK IN
ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICE FOR ACHIEVING AIR TIGHT (5% LEAKAGE) AND
NOISELESS (NO OBJECTIONABLE NOISE SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED
SERVICE. FURNISH ALL REQUIRED DAMPERS, TRANSITIONS, CONNECTIONS TO AIR TERMINALS, AND
OTHER ACCESSORIES NECESSARY FOR A COMPLETE OPERATING SYSTEM. NO VARIATION OF DUCT
CONFIGURATION OR SIZES WILL BE PERMITTED EXCEPT BY PERMISSION FROM THE ENGINEER.
MOUNT DUCTWORK AS HIGH AS POSSIBLE TO UNDERSIDE OF STRUCTURE. (NO SQUARE THROAT
ELBOWS SHALL BE INSTALLED WITHOUT DOUBLE THICKNESS TURNING VANES.) ALL DUCT
CONNECTIONS TO EQUIPMENT SHALL BE LOADED TYPE VINYL, VIBRATION ELIMINATION
CONNECTIONS, (F.C.) FLEXIBLE CONNECTIONS. DUCTWORK TRANSITIONS SHALL BE (FOT) ''FLAT ON
TOP'' UNLESS OTHERWISE SPECIFIED ON PLAN. ALL BRANCH SUPPLY DUCTS SHALL HAVE (VD) MANUAL
VOLUME DAMPERS INSTALLED FOR BALANCING, SEE SYMBOL LIST. ALL ROOF PENETRATIONS
EXCEEDING 12'' X 12'' IN SIZE SHALL BE FURNISHED WITH BURGLAR BARS. ALL CONTRACTOR
FABRICATED AND MANUFACTURER FABRICATED COMPONENTS OF THE OUTSIDE AIR, SUPPLY AIR,
RETURN AIR AND EXHAUST SYSTEMS SHALL BE CONSTRUCTED AND INSTALLED AIR-TIGHT. THE
INSTALLED SYSTEMS SHALL BE PRESSURE TESTED AS SPECIFIED. PIPE OPENINGS IN SYSTEM
COMPONENT SHALL HAVE SHEET METAL BAFFLES, SET IN SEALANT, TO PREVENT LEAKAGE. ALL DUCT
DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR OUTSIDE DIMENSIONS.
SUPPORTS
PROVIDE HOT-DIPPED GALVANIZED STEEL, FASTENERS, ANCHORS. RODS, STRAPS, TRIM, AND
ANGLES FOR SUPPORT OF DUCTWORK.
ROUND TAKE-OFF FROM DUCT
WITH MANUAL BALANCE DAMPER
DEVICE
TYPE
FIRE PROTECTION SYSTEM:
DUCTWORK & ACCESSORIES:
WALK IN FREEZER/COOLER:
7.
ALL NEW SUPPLY, RETURN AND OUTSIDE AIR RECTANGULAR/SQUARE DUCTWORK
SHALL BE INSULATED WITH 1'' THICK, 2 PCF DUCT LINER. DUCT LINER SHALL BE
FASTENED TO INSIDE OF DUCTWORK AS PER MANUFACTURER'S DIRECTIONS AND
S.M.A.C.N.A. ''DUCT LINER APPLICATION STANDARD''. ALL NEW SUPPLY, RETURN AND
OUTSIDE AIR ROUND/OVAL DUCTWORK , WHICH ARE NOT LINED, SHALL BE INSULATED
WITH 1-1/2'' THICK FLEXIBLE INSULATION, 1 PCF DENSITY FOIL REINFORCED KRAFT
FACING. DUCT WRAP SHALL BE FASTENED TO DUCTWORK AS PER MANUFACTURER'S
DIRECTIONS. THE ROUND BRANCH DUCTWORK SHALL BE INSULATED WITH 1'' THICK
FIBERGLASS SLEEVE WITH FOIL JACKET AND ALL JOINTS AND TERMINATIONS SEALED
WITH FOIL OR DUCT TAPE. ROUND/OVAL SUPPLY AND RETURN DUCTWORK EXPOSED
TO VIEW AND LOCATED IN THE CONDITIONED SPACE SHALL NOT BE INSULATED.
EXTERIOR DUCTWORK TO BE 1-1/2" LINED AND WEATHERPROOFED. DUCTS TO BE LINED:
a.)
ALL RECTANGULAR CONCEALED AND EXPOSED SUPPLY DUCTWORK.
b.)
ALL RETURN DUCT WORK FROM GRILLES TO ROOFTOP UNITS
c.)
ALL EXHAUST DUCT RISERS TO ROOF FANS AND FOR A DISTANCE OF 5'-0" FROM
VERTICAL DUCT CONNECTION.
d.)
ANY OTHER DUCTWORK SPECIFICALLY NOTED ON THE CONTRACT DRAWINGS.
8. ALL FLEXIBLE DUCTWORK SHALL BE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181)
WITH FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR
BARRIER. FLEX DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE
DEVELOPED UNDER 50, AND SHALL BE RATED FOR 2'' W.C. PRESSURE AND 0 TO 250
DEGREE TEMPERATURE. MAXIMUM STRETCHED OUT LENGTH SHALL BE 6'-0''.
COOLER INFORMATION
THE VOLUME OF THE COOLER IS 541.3 CUBIC FEET. THE COOLER USES 2.9 POUNDS R-22
REFRIGERANT. THE COOLER HAS A 1 HP MOTOR AND THE COMPRESSOR IS A REMOTE THAT IS
MOUNTED ON THE ROOF.
FREEZER INFORMATION
THE VOLUME OF THE FREEZER IS 230.4 CUBIC FEET. THE FREEZER USES 3.5 POUNDS R-404a
REFRIGERANT. THE FREEZER HAS A 1.5 HP MOTOR AND THE COMPRESSOR IS A REMOTE THAT IS
MOUNTED ON THE ROOF.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
ENERGY CODE COMPLETION:
DRAWINGS
WITHIN 90 DAYS OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL PROVIDE RECORD DRAWINGS OF
THE ACTUAL INSTALLATION TO THE BUILDING OWNER OR THE DESIGNATED REPRESENTATIVE OF THE
BUILDING OWNER. RECORD DRAWINGS INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE
DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION
SYSTEM INCLUDING SIZES, AND THE TERMINAL AIR OR WATER DESIGN FLOOR RATES.
MANUAL
WITHIN 90 DAYS OF SYSTEM ACCEPTANCE, CONTRACTOR SHALL PROVIDE AN OPERATING AND
MAINTENANCE MANUAL TO THE BUILDING OWNER, OR DESIGNATED REPRESENTATIVE OF THE
BUILDING OWNER. THESE MANUALS SHALL BE IN ACCORDANCE WITH INDUSTRY ACCEPTED
STANDARDS AND SHALL INCLUDE, AT A MINIMUM, THE FOLLOWING:
- SUBMITTAL DATA STATING EQUIPMENT SIZES AND SELECTED OPTIONS FOR EACH PIECE OF
EQUIPMENT REQUIRING MAINTENANCE.
- OPERATIONS MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OF EQUIPMENT REQUIRING
MAINTENANCE EXCEPT EQUIPMENT NOT FURNISHED AS PART OF THE PROJECT. REQUIRED ROUTINE
MAINTENANCE ACTIONS SHALL BE CLEARLY IDENTIFIED.
- NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY.
- HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING
DIAGRAMS, SCHEMATICS AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR FIELD DETERMINED
SET-POINTS SHALL BE PERMANENTLY RECORDED ON CONTROL DRAWINGS AT CONTROL DEVICES OR
FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS.
- A COMPLETE NARRATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE, INCLUDING SUGGESTED
SET-POINTS.
E
955
PROJECT NUMBER: 16-059
DETAIL
ROOFTOP UNIT EQUIP. & MATERIALS:
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
HVAC SYMBOLS LEGEND
SHEET TITLE
MECHANICAL
LEGEND &
NOTES
SHEET NUMBER
M1.0
KEYNOTES
3
PROVIDE MANUAL VOLUME DAMPER TO AIR DEVICE. TYPICAL FOR ALL "S1" GRILLES.
4
PROVIDE SMOKE DETECTOR IN MAIN RETURN DUCT OF RTU WHICH WILL DE-ENERGIZE THE
UNIT UPON SMOKE DETECTION. INTERLOCK WITH FIRE ALARM SYSTEM IF APPLICABLE.
VERIFY ALL REQUIREMENTS WITH LOCAL CODES & LANDLORD.
5
RTU-1, RTU-2
2 ROOFTOP UNITS FURNISHED BY PSW & INSTALLED BY CONTRACTOR. BALANCE SUPPLY,
RETURN AND OUTDOOR AIR FLOWS PER SCHEDULE ON SHEET M3.0. PROVIDE WITH 3 SETS OF
FILTERS FOR EACH UNIT - ONE SET FOR USE DURING CONSTRUCTION, ONE SET INSTALLED
AT COMPLETION OF CONSTRUCTION AND ONE SPARE SET FOR TENANT.
6
EF-1
EXHAUST FAN & KITCHEN EXHAUST HOOD PROVIDED BY VENDOR & INSTALLED BY
CONTRACTOR. CONTRACTOR TO MAKE ALL CONNECTIONS BETWEEN HOOD AND EXHAUST
FAN. CONTRACTOR RESPONSIBLE FOR COORDINATION BETWEEN LANDLORD AND ROOFING
CONTRACTOR.
7
DUCT CONNECTIONS TO RTU SHALL BE MADE FULL SIZE OF EQUIPMENT OPENING WITH
FLEXIBLE DUCT CONNECTIONS AT UNIT AND THEN TRANSITION TO THE SIZES AND LOCATIONS
SHOWN. TYPICAL FOR SUPPLY AND RETURN DUCTS.
8
SPRINKLER HEADS SEE SHEET M1.0.
9
MOUNT DUCTWORK AS HIGH AS POSSIBLE. VERIFY MOUNTING HEIGHT OF DUCTWORK WITH
ARCHITECT.
10
16" DIA. EXHAUST DUCT UP FROM HOOD, WITH VOLUME DAMPER, TO 18" DIA. DUCTWORK UP
TO EXHAUST FAN EF-1 ON ROOF. VERIFY LOCATION IN FIELD WITH LANDLORD
REPRESENTATIVE.
11
FURNISH AND INSTALL GALVANIZED STEEL DUCTWORK, SIZES AS SHOWN ON DRAWINGS.
SIZES SHOWN ARE SHEET METAL SIZES. INSULATE ALL RECTANGULAR DUCTWORK ABOVE
CEILINGS WITH 1-1/2" EXTERNAL WRAP WITH VAPOR BARRIER. SEE SHEET M4.0 FOR DETAILS.
12
SUPPLY DUCT CONNECTION TO AIR DEVICE. SEE AIR DEVICE RUNOUT SCHEDULE FOR SIZE.
INSTALL A VOLUME DAMPER AT TAKE-OFF FROM SUPPLY DUCT MAIN. TYPICAL FOR ALL "S2"
GRILLES.
13
EXHAUST DUCT, 8"x8", UP TO EXHAUST FAN EF-2 ON ROOF. VERIFY LOCATION IN FIELD.
14
4" PVC/CPVC INTAKE AND 4" PVC/CPVC EXHAUST UP TO ROOF. COMBINE RIGHT BEFORE ROOF
PENETRATION WITH CONCENTRIC VENT KIT.
15
FURNISH AND INSTALL HUMIDITY SENSOR IN RETURN AIR DUCT TO MAINTAIN 50% RELATIVE
HUMIDITY IN SPACE.
S
10
12
15 H
7
15
NOTES:
VERIFY EXHAUST DUCT TERMINATIONS ARE A MINIMUM OF 10'-0" AWAY FROM ANY
OUTSIDE AIR INTAKES FOR BUILDING.
10
H
4
7
5
1
13
A
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
R
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
ISSUE
DD SET
95% SET
S
14
mechanical
electrical
plumbing
fire protection
structural
DATE
04-26-2016
05-23-2016
8
3
2
S
S
1
1
SHEET TITLE
MECHANICAL
PLAN
NORTH
SHEET NUMBER
SCALE: 1/4"=1'-0"
S
0334
ISSUE DATE
11
MECHANICAL
PLAN
01
E
955
4
5
9 11
6
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
PROJECT NUMBER: 16-059
2
SEE SUBMARINE DETAIL DRAWING 10/M4.0. SEE ARCHITECTURAL DRAWINGS FOR SUBMARINE
HANGING INSTRUCTIONS. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR SHALL CONTACT
OWNERS PROJECT MANAGER FOR EXACT INSTALLATION ANGLES. SUBMARINE IS MADE OF
SHEET METAL DUCTWORK. SUBMARINE IS ATTACHED IN THE SAME FASHION AS DUCTWORK.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
THERMOSTAT
INSTALL THERMOSTAT AND AVERAGING REMOTE SENSORS AS SHOWN. COORDINATE EXACT
LOCATION WITH OWNER REP. MOUNT T-STATS AS INDICATED ON DWGS. MOUNT SENSORS
AT 60" A.F.F. U.N.O. IN LOCKABLE ENCLOSURE. COORDINATE WITH ELECTRICAL CONTRACTOR
FOR BACKBOX. CONTRACTOR TO VERIFY COMPATIBILITY AND WIRE T-STATS AND SENSORS
TO HVAC UNITS.
1
T T 1
12
1
M2.0
AIR DEVICE SCHEDULE
ROOFTOP UNIT SCHEDULE
HEATING
TAG
MANUF / MODEL
CFM
O.A. CFM
E.S.P.
VOLTS/
PHASE
RTU-1
TRANE YHC120
3400
1150
0.6
460
RTU-2
TRANE YHC120
3400
1150
0.6
460
FAN HP
3
3
MCA/MOCP
3.6
24.9
3.6
24.9
EER/SEER
INPUT OUTPUT
MBH
MBH
12.5
30
12.5
30
-
COOLING
NOM.
TONS
TOTAL
MBH
SENS.
MBH
ENT.
D.B.
ENT.
W.B.
UNIT
WEIGHT
REMARKS
250
200
10.0
109.4
83.5
76°F
66°F
1608
1, 2, 3, 4
250
200
10.0
109.4
83.5
76°F
66°F
1608
1, 2, 3, 4
MARK
RECT. NECK SIZE
ROUND NECK
SIZE
FACE SIZE
S1
10X8"
-
3
13X916
"
S2
-
SCHEDULE
24X24"
S3
-
SCHEDULE
S4
-
SCHEDULE
THROW
PATTERN
MOUNTING
MANUFACTURER/MODEL
NOTES
DUCT
METALAIRE 4004P-1
1
4-WAY
CEILING
TITUS PAS
1
24X24"
4-WAY
CEILING
TITUS TDC
1
12X12"
4-WAY
CEILING
TITUS TDC
1
R1
-
SCHEDULE
24X24"
-
CEILING
TITUS 355RL
R2
18X16"
SCHEDULE
20X18"
-
WALL
TITUS 355ZRL
E1
-
8" DIA
12X12"
4-WAY
CEILING
TITUS 355RL
E2
-
6" DIA
12X12"
4-WAY
CEILING
TITUS 355RL
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
1
A
A.
DEVICES SHALL BE WHITE FROM THE MANUFACTURER AND PAINT TO MATCH CEILING OR WALL.
B.
DEVICES SHALL BE SILVER MILL FINISH FROM THE MANUFACTURER WHEN IN METAL PANEL CEILING SYSTEM.
C.
ALL DEVICES SHALL BE 4-WAY UNLESS SHOWN OTHERWISE
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
D.
CONTRACTOR IS RESPONSIBLE FOR VERIFING QUANTITIES AS SHOWN ON PLANS.
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
NOTES:
1.
C
Wells
ILLINOIS DESIGN FIRM # 184.006688
GENERAL NOTES:
NOTES:
1.
VERIFY EXISTING ELECTRICAL WITH ELECTRICAL CONTRACTOR.
2. ROOFTOP UNITS PROVIDED BY PSW AND INSTALLED BY CONTRACTOR. UNIT TO BE PROVIDED WITH FULL ECONOMIZER, BAROMETRIC RELIEF DAMPER & EXPANDED METAL HAIL GUARDS. VERIFY LOCATION
AND PROPER OPERATION WITH LANDLORD REPRESENTATIVE. ROOFTOP UNIT CONVENIENCE OUTLET SHALL BE GFI.
3. INSTALL DUCT SMOKE DETECTORS, FIELD INSTALLED AS SHOWN ON PLANS. RTU SHALL SHUT DOWN AND SIGNAL FIRE ALARM SYSTEM (IF APPLICABLE) WHEN ACTIVATED.
4. PROVIDE UNIT WITH HOT GAS REHEAT OPTION AND HUMIDITY SENSOR. SEE PLANS ON SHEET M2.0 FOR HUMIDITY SENSOR LOCATION.
R
4 0 4 S.
PROVIDE WITH DAMPER.
St. Louis - Montreal
EXHAUST HOOD SCHEDULE
EXHAUST PLENUM
RISER(S)
HOOD SIZE
TOTAL
EXH. CFM
DIAMETER
CFM
S.P.
HOOD WEIGHT
FAN SERVING
HOOD
HOOD CONSTRUCTION
REMARKS
KH-1
GREASEMASTER
3624
5'-0" L X 3'-0"
1000
16"
1000
-0.086
136 LBS
EF-1
430 SS WHERE
EXPOSED
1
KH-2
GREASEMASTER
3624
5'-0" L X 3'-0"
1000
16"
1000
-0.086
136 LBS
EF-1
430 SS WHERE
EXPOSED
1
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
AIR DEVICE RUNOUT SCHEDULE
NOTES:
1. EXHAUST FANS & KITCHEN HOODS PROVIDED BY PSW VENDOR AND INSTALLED BY CONTRACTOR. SEE SHEET M6.0 FOR ADDITIONAL INFORMATION.
DUCT CFM
0 - 100
101 - 230
231 - 420
421 - 680
681 - 1030
1031 - 1450
1451 - 2000
2001 - 2600
FAN SCHEDULE
MARK
CFM
S.P.
EF-1
2000
.75"
VOLTS/PHASE
115
FAN HP
AREA SERVED
MANUFACTURER/MODEL
WEIGHT
NOTES
.75
KH-1 & KH-2
GREASEMASTER GM14-FA
134
SEE SHEET M6.0 FOR FULL
DETAIL/SPECIFICATION
.06
TOILET ROOMS
GREASEMASTER GMDR10H
36
SEE SHEET M6.0 FOR FULL
DETAIL/SPECIFICATION
1
EF-2
200
.375"
115
1
BDD = BACKDRAFT DAMPER
DS = NON-FUSED SERVICE DISCONNECT
BS = BIRDSCREEN
EC = EPOXY COATING
DDP = DOWN DISCHARGE PLENUM
FILT = PERMANENT FILT.
DIT = DUCT INLET TRANSITION
GB = GREASEBOX
MEP= MASTER ELECTRIC PANEL
SI = SIDE INLET
RC = ROOF CURM
SIT = SIDE INLET TRANSITION
SCR = SPEED CONTROL
WD = WEATHER HOOD
SD = SIDE DISCHARGE
PE = PREMIUM EFFICIENCY MOTOR
WC = WALL CAP
mechanical
electrical
plumbing
fire protection
structural
DUCT SIZE
6" ROUND
8" ROUND
10" ROUND
12" ROUND
14" ROUND
16" ROUND
18" ROUND
20" ROUND
GENERAL NOTES
1.
AIR DEVICE NECK SIZE SHALL BE THE SAME AS RUNOUT SIZE.
2. RECTANGULAR DUCT SIZES OF EQUIVALENT FREE AREA MAY BE BE SUBSTITUTED FOR
ROUND DUCT.
2. RUNOUTS MAY BE RIGID OR FLEX DUCT PER SPECIFICATIONS.
AIR BALANCE SCHEDULE
TAG
OUTSIDE AIR
RETURN AIR
SUPPLY AIR
EXHAUST AIR
PRESSURE
PERCENT OUTSIDE AIR
RTU-1
1150
2250
3400
0
+1150
34%
RTU-2
1150
2250
3400
0
+1150
34%
EF-1
0
0
0
2,000
-2,000
---
EF-2
0
0
0
200
-200
---
TOTAL:
PROJECT NUMBER: 16-059
MANUF / MODEL
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
TAG
+100
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
MECHANICAL
SCHEDULES
SHEET NUMBER
M3.0
LIQUID
RECEIVER
NOTE:
DIVE TO 20 DEGREE CANT. 24 HOURS PRIOR TO INSTALLATION CONTRACTOR
SHALL CONTACT OWNER'S PROJECT MANAGER FOR EXACT INSTALLATION
ANGLES. PROPELLAR TO SPIN FREELY WITH AIR FLOW.
TRAPEZE HANGERS
RELIEF/SAFETY
VALVE
ROD
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
10"~ TO 6"~ TALL
CONE
CAP
CONDENSING
UNIT
NAILER
6"~ TO 2-1/2"X12"
HORN BOOT
1" WIDE, 18 GA.
SUPPORT STRAP w/
5'-0" MAXIMUM
SPACING
STRAP HANGERS
60"
MAX.
(EXPOSED DUCTWORK ONLY, USE RECTANGULAR
DUCT IF ABOVE CEILING)
CONTINUOUS HANGER
STRAP AROUND DUCT
ROUND DUCT SUPPORT DETAIL
4"
Scale: N.T.S.
Ø1'-
2'-6"
4
Scale: N.T.S.
7
WALK-IN COOLER PIPING DIAGRAM
Scale: N.T.S.
4"
10
45° CLINCH COLLAR
WITH GASKET
~
O
PLAN VIEW
18" ENCLOSURE PANEL
(SHIPPED LOOSE)
CFL LIGHT (INTEGRAL)
MESH FILTER
HANGER BRACKET
ROUND DUCTS R=3W/2
(CENTERLINE STD RADIUS)
RECTANGULAR DUCTS R1 MIN.
4", R2=R1 + W
TYPICAL MANUAL
VOLUME DAMPER
REFER TO SPECIFICATIONS
FOR PRESSURE AND SEAL
CLASSIFICATIONS
R
R2
1'-6"
1'-6"
S
+
IL
P
L
A
60607
N
N
P:
312
3'-0"
SUPPLY OR RETURN DUCT
Scale: N.T.S.
11
ISSUE
DD SET
95% SET
NOT USED
Scale: N.T.S.
SHOP FABRICATED SHT MTL CLG
DIFUSSER CAP NET INSIDE DIM.
SAME AS DIFFUSER NECK
FRONT VIEW
OPPOSED BLADE DAMPER
TITUS AG-75 OR EQUAL
WHEN REQ'D
EQUALIZING GRID PERPEND TO STUB DUCT.
FULL SIZE OF DIFFUSER CAP. HEIGHT FROM
DIFFUSER NECK TO STUB CNTRLN.
FABRICATE FROM 22GA PERF SHT MTL (163 "
HOLES ON 41" CNTRS).
7'-0"
-ONE UNIT REQUIRED PER OVEN LOCATION
NOTE: HOOD AND EXHAUST FANS BY VENDOR;
DUCTS BY G.C.
EQUIPMENT
BY OTHERS
EXPOSED MATERIAL:
18 GA TYPE 430 S/S, #3 POLISH
LIGHTS:
(2) CFL (INTEGRAL-BULBS SUPPLIED) BY VENDOR
FILTERS:
(1) 20x20 ALUMINUM MESH
CONTROLS:
FAN SPEED CONTROLLER, ON-OFF LIGHTED LIGHT
SWITCH
SWITCHES TO BE LOCATED AT MASTER SWITCH BANK
EXHAUST:
300-1000 CFM
NOTES:
1. PROVIDE SUPPORT FOR
DIFFUSER & CAP PER CODE
FLEX DUCT CLAMP
FLEX DUCT. PULL INSIDE
LINER TAUT
CLG DIFFUSER. FASTEN TO CAP W/
SHT MTL SCREWS, MIN ONE PER
SIDE. SEAL JOINT AIR TIGHT
SHEET TITLE
MECHANICAL
DETAILS
2. EQUALIZING GRID REQ'D ON
SUPPLY AIR DIFFUSERS ONLY
TYP SUSP LAY-IN CEILING
SHEET NUMBER
SIDE VIEW
3
TYPE II KITCHEN HOOD
Scale: N.T.S.
9
R
S
0334
DATE
04-26-2016
05-23-2016
ROUND INSUL STUB DUCT
SAME SIZE AS FLEX DUCT
5'-0"
E
955
mechanical
electrical
plumbing
fire protection
structural
6"
6"
T
Chicago,
ISSUE DATE
W
8
C
R1
3"
3"
HANGER BRACKET
18" ENCLOSURE PANEL
(SHIPPED LOOSE)
E
300
Scale: N.T.S.
3'-0"
6"
5'-0"
T
Suite
SUBMARINE DETAIL
TYPICAL
ROUND DUCT
STANDARD
BELLMOUTH
ECCENTRIC
TRANSITION ~
Ω=30° MAX
I
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
AD
ACCESS DOOR
WITH PIANO HINGE
AND SASH LOCK
4'-0"
S t .,
St. Louis - Montreal
SOLID ROUND
ELBOW
1'-6"
2'-0"
2-1/2"X12" REG.
TAPERED
4"
6"
H
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
VERTICAL
RETURN DUCT
EXHAUST
C
Wells
ROOM DIFFUSER
OR REGISTER
TYPE RE2 SQUARE
THROAT ELBOW
WITH DOUBLE WALL
VANES
VERTICAL SUPPLY
DUCT
R
4 0 4 S.
ILLINOIS DESIGN FIRM # 184.006688
1/2" HOLES DRILLED
INTO COVER
NOTES: 1. REMOVE EXPANSION VALVES, DEVICES AND CONNECTIONS FROM
THE AIR STREAM.
2. INSTALL PRESSURE RELIEF VALVE ON HIGH PRESSURE SIDE OF
SYSTEM, UPSTREAM FROM ANY LIQUID LINE SHUT-OFF VALVES.
3. REFRIGERATION PIPING TO BE TYPE 'K' COPPER.
4. ALL REFRIGERATION PIPING JOINTS TO BE BRAZED.
5. VERIFY REFRIGERANT LINE SIZE PER MANUFACTURERS
INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION.
6. GC TO PROVIDE ANY NECESSARY CONDUIT AND PENETRATIONS.
FIRE DAMPER STYLE B,
WITH DAMPER CURTAIN
OUT OF AIRSTREAM.
CONSTRUCTION AS PER
NFPA90A
A
PROPELLER
EXPANSION
VALVE
UNIT COOLER
(EVAPORATOR COIL)
DUCT SUPPORT DETAIL
12"~ TO 8"~ TALL
CONE
LIQUID LINE, 3/8" O.D. "K"
COPPER
UNLESS FOOT OF
STRAP IS PLACED
UNDER A BOTTOM
REINFORCEMENT
6"~ TO 2-1/2"X12" HORN
BOOT
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
ROUND RIGID DUCT
SUCTION LINE, 5/8" O.D. "K"
COPPER
HANGER STRAPS
1
2-1/2"X12" REG.
TAPERED
JOIST
SIZE BOLT(S)
FOR LOAD
12"~ SPIRAL DUCT
PROJECT NUMBER: 16-059
STRAP OR ANGLE
3"~ ELBOW
LAY-IN CLG DIFFUSER
Scale: N.T.S.
12
NOT USED
Scale: N.T.S.
13
NOT USED
Scale: N.T.S.
M4.0
KEYNOTES
1
NEW ROOFTOP UNIT, RTU-1. VERIFY EXACT LOCATION AND PROPER OPERATION IN FIELD.
2
NEW ROOFTOP UNIT, RTU-2. VERIFY EXACT LOCATION AND PROPER OPERATION IN FIELD.
3
NEW EXHAUST FAN, EF-1, FOR KITCHEN HOOD.
4
NEW EXHAUST FAN, EF-2, FOR TOILET ROOMS.
5
FLUE FROM WATER HEATER.
6
NEW REMOTE CONDENSER FOR COOLER/FREEZER.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
2
1
4
3
PROJECT NUMBER: 16-059
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
mechanical
electrical
plumbing
fire protection
structural
6
ISSUE DATE
6
ISSUE
DD SET
95% SET
5
DATE
04-26-2016
05-23-2016
SHEET TITLE
NORTH
01 MECHANICAL ROOF PLAN
MECHANICAL
ROOF
PLAN
SHEET NUMBER
SCALE: 1/4"=1'-0"
M5.0
REVISIONS
3624
1
GC-1
3624
2
MAX.
COOKING
TEMP.
TOTAL EXH.
CFM
5' 0.00"
300 Deg.
5' 0.00"
300 Deg.
LENGTH
GC-1
WIDTH
LENG.
DIA.
CFM
S.P.
1000
4"
16"
1000
-0.086"
1000
4"
16"
1000
-0.086"
FILTER(S)
HOOD
NO.
TAG
TYPE
QTY.
HOOD CONSTRUCTION
HEIGHT
HEIGHT
430 SS
100%
430 SS
100%
END TO
END
ROW
FAN
UNIT NO.
TAG
FAN UNIT MODEL #
CFM
ESP.
RPM
H.P.
B.H.P.
Ø
VOLT
FLA
WEIGHT
(LBS.)
SONES
ALONE
ALONE
1
EF-1
GM14-FA
2000
0.750
1283
0.750
0.6900
1
115
6.8
134
14.9
ALONE
ALONE
2
EF-2
GMDR10H
200
0.375
1351
0.060
0.0490
1
115
1.0
36
4.9
FAN
UNIT
NO.
TAG
1
EF-1
2
EF-2
LIGHT(S)
LENGTH
EFFICIENCY @ 9
QTY.
MICRONS
TYPE
WIRE
GUARD
UTILITY CABINET(S)
FIRE SYSTEM
LOCATION
SIZE
TYPE
SIZE
ELECTRICAL
SWITCHES
MODEL #
QUANTITY
FIRE
SYSTEM
PIPING
HOOD
HANGING
WGHT
1
2
Screw In Compact
NO
NO
136 LBS
2
2
Screw In Compact
NO
NO
136 LBS
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
OPTION (Qty. - Descr.)
LISTED
MODEL
BUILT
IN
ACCORDANCE
WITH
NFPA
No. 96
TAG
HOOD CONFIG.
R
HOOD
NO.
EXHAUST PLENUM
RISER(S)
1 - I 19-BDD Damper
1 - SCR-15 Bird Screen
A
1 - I 12-BDD Damper
R
4 0 4 S.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
HOOD
NO.
1
2
TAG
OPTION
WRAPPER CHANNEL - Front, Left, Right, Back
NO.
ON FAN
WEIGHT
ITEM
1
#1
29 LBS
Curb
23.000"W x 23.000"L x 18.000"H
2
#2
22 LBS
Curb
17.500"W x 17.500"L x 18.000"H
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
SIZE
WRAPPER CHANNEL - Front, Left, Right, Back
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Left 430 SS
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Front 430 SS
FAN #1 GM14-FA - EXHAUST FAN (EF-1)
St. Louis - Montreal
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Right 430 SS
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Back 430 SS
23"
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Left 430 SS
33 3/4
FEATURES:
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Front 430 SS
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 24.00" Long Right 430 SS
- ROOF MOUNTED FANS
OPTIONS ONLY: FIELD WRAPPER 18.00" High x 48.00" Long Back 430 SS
- UL705
23"
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
- AMCA SOUND AND AIR CERTIFIED
mechanical
electrical
plumbing
fire protection
structural
CURB
- INTERNAL WIRING
- WEATHERPROOF DISCONNECT
18"
- THERMAL OVERLOAD PROTECTION (SINGLE PHASE)
I 19-BDD DAMPER
SCR-15 BIRD SCREEN
23
3" FLANGE
BACKDRAFT DAMPER INSTALLATION
2
AIR FLOW
ROOF OPENING
DIMENSIONS
21
BACKDRAFT DAMPER
21
14 7/8
21
24 3/4
21
(ROOF OPENING)
17 1/2"
17 1/2"
FEATURES:
- DIRECT DRIVE CONSTRUCTION
20 3/4
(NO BELTS/PULLEYS)
- ROOF MOUNTED FANS
CURB
- UL705
18"
- SAFETY DISCONNECT
- STANDARD BIRD SCREEN
20 GAUGE
STEEL
CONSTRUCTION
- SPEED CONTROL
OPTIONS
I 12-BDD DAMPER
14 1/2
3" FLANGE
13
13
HOOD IS TYPE II-NON GREASE
8 1/8
13
2
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
BACKDRAFT DAMPER INSTALLATION
DATE:
AIR FLOW
19
HOOD & FAN PACKAGE
PROVIDED DIRECT TO
OWNER. CONTACT DIRK
BAUMANN @ J.D. HIGGINS
COMPANY FOR ADDITIONAL
INFORMATION @ 800-772-5452
ROOF OPENING
DIMENSIONS
ISSUE DATE
LINTHICUM HEIGHTS, MD, 21090
FAN #2 GMDR10H - EXHAUST FAN (EF-2)
PROJECT NUMBER: 16-059
30 1/2
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
20 GAUGE
STEEL
CONSTRUCTION
OPTIONS
Potbelly- Linthicum Heights, MD
3
BACKDRAFT DAMPER
DWG.#:
2661219
DRAWN
BY:
SCALE:
SHEET TITLE
MASTER DRAWING
EXHAUST
HOOD
DRAWINGS
SHEET NO.
SHEET NUMBER
13
(ROOF OPENING)
M6.0
SOIL, WASTE AND VENT PIPING
SOIL, WASTE AND VENT PIPING 10" AND SMALLER SHALL BE SERVICE WEIGHT, HUBLESS, CAST
IRON PIPE AND FITTINGS WITH NEOPRENE GASKET AND STAINLESS STEEL SHIELD AND CLAMP.
PROVIDE HUB & SPIGOT, SERVICE WEIGHT CAST-IRON SOIL PIPE AND FITTINGS BELOW GRADE
WHERE REQUIRED BY LOCAL CODES. ALL HORIZONTAL RUNS SHALL DRAIN AT A GRADE 41" PER
FOOT. COORDINATE WITH LOCAL AUTHORITIES FOR DRAINAGE REQUIREMENTS FOR EQUIPMENT
DESIGNATED WITH INDIRECT WASTE TO FLOOR DRAINS. PROVIDE PIPED DRAIN TO SANITARY IF
REQUIRED BY LOCAL JURISDICTION.
WATER SERVICE
COLD WATER SUPPLY PIPING
HOT WATER SUPPLY PIPING
HOT WATER RETURN PIPING
SANITARY DRAINAGE & WASTE PIPING/SEWER
DOMESTIC WATER PIPING
DOMESTIC WATER PIPING 221" AND SMALLER SHALL BE COPPER TUBE WITH WROUGHT COPPER
SWEAT FITTINGS JOINED WITH NON-LEAD, NON-ANTIMONY SOLDER. PROVIDE TYPE "L" COPPER
TUBE ABOVE GRADE AND TYPE "K" BELOW GRADE.
SANITARY VENT PIPING
NATURAL GAS PIPING
G
CONDENSATE DRAINAGE PIPING
THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS FOR AIR HANDLING UNITS
AND POTBELLYS EQUIPMENT (REFER TO SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE
TYPE "M" COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED WITH 50/50 SOLDER.
LINE SIZE GATE VALVE
LINE SIZE BALL VALVE (2'' & SMALLER)
LINE SIZE CHECK VALVE
HANGERS & SUPPORTS
THE PLUMBING CONTRACTOR SHALL FURNISH ALL PIPE SUPPORTS REQUIRED FOR EQUIPMENT
AND MATERIAL. ALL HORIZONTAL RUNS OF PIPING SHALL BE SUPPORTED BY PIPE HANGERS
INSTALLED AS REQUIRED BY LOCAL CODES ADDITIONAL SUPPORTS SHALL BE PROVIDED WHERE
REQUIRED TO PREVENT SAGGING. HANGERS AND PIPE ATTACHMENTS TO BE FACTORY
FABRICATED WITH GALVANIZED COATINGS; NONMETALLIC COATED FOR HANGERS IN DIRECT
CONTACT WITH COPPER TUBING.
LINE SIZE UNION
LINE SIZE GAS COCK VALVE
ABOVE FINISHED FLOOR
CB
CAST BRASS
CIP
CAST IRON PIPE
CI
CAST IRON
CO
CLEANOUT
CP
CHROME PLATED
ETR
EXISTING TO REMAIN
FCO
FLOOR CLEANOUT
FD
FLOOR DRAIN
GW
GREASE WASTE
NC
NEW CONNECTION
S
SANITARY
V
VENT
VTR
CONNECTIONS
INSTALL UNIONS ADJACENT TO EACH VALVE AND AT FINAL CONNECTION TO EACH PIECE OF
EQUIPMENT. INSTALL DIELECTRIC COUPLINGS TO CONNECT PIPING MATERIALS OF DISSIMILAR
METALS. SCREW JOINT STEEL PIPING UP TO AND INCLUDING 1-1/2". WELD PIPING USE NON-LEAD,
NON-ANTIMONY SOLDER FOR SOLDERING DOMESTIC WATER COPPER PIPE.
CLEANOUTS
PROVIDE J.R. SMITH OR EQUIVALENT FLOOR AND WALL CLEANOUTS AS INDICATED ON THE
DRAWINGS OR WHERE REQUIRED BY CODE IN ALL SOIL, WASTE, AND DRAIN LINES. IN AREAS WITH
CERAMIC TILE OR CARPETED FLOORING, PROVIDE CLEANOUTS WITH SQUARE, ADJUSTABLE,
NICKEL BRONZE TOP. IN AREAS WITH RESILIENT FLOORING, PROVIDE CLEANOUTS WITH SQUARE,
ADJUSTABLE, NICKEL BRONZE TOP WITH TILE RECESS. CLEANOUTS SHALL BE SAME SIZE AS PIPE
EXCEPT THAT CLEANOUTS LARGER THAN 4" WILL NOT BE REQUIRED. WHERE CLEANOUTS OCCUR
IN WALLS OF FINISHED AREAS, THEY SHALL BE CONCEALED BEHIND CHROME PLATED ACCESS
COVERS.
RECOMMENDED FLOOR SINK
LOCATION. VERIFY WITH ARCHITECT.
IND
INDIRECT WASTE DRAIN, HUB DRAIN, FLOOR DRAIN W/
FUNNEL OR SIMILAR. VERIFY WITH ARCHITECT
FD
FLUSH FLOOR DRAIN AND GRATE
CONSTRUCTION AND BIDDING NOTES:
THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND
FULLY OPERATIONAL PLUMBING SYSTEM. THE CONTRACTOR SHALL FURNISH ALL LABOR,
MATERIAL AND EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK.
2.
THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE FIXTURES, EQUIPMENT,
AND PIPING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION,
PREVENTS THE PROPER INSTALLATION OF THE PLUMBING WORK.
3.
4.
5.
6.
7.
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF ASME,
ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR
ASSEMBLY.
CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE
STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE
DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD
SHALL APPLY. THE CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM
STANDARD WITHOUT ANY EXTRA COST TO POTBELLY.
THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS
NECESSARY TO COMPLETE THE PLUMBING WORK.
THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS
IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL
ACCEPTANCE BY POTBELLY AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN
THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP.
THIS CONTRACTOR SHALL OBTAIN A COPY OF THE WORK LETTER FROM THE PSW
CONSTRUCTION MANAGER PRIOR TO SUBMISSION OF THE BID. THIS CONTRACTOR SHALL
SUBMIT SAID WORKLETTER AS EVIDENCE OF HAVING REVIEWED CONTRACTORS
RESPONSIBILITIES WITHIN SCOPE OF WORK. ANY DISCREPANCIES BETWEEN THE
WORKLETTER AND THE DESIGN DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE
PSW CONSTRUCTION MANAGER, BEFORE BID DUE DATE.
8.
PROVIDE AND INSTALL ALL "P" TRAPS, MANIFOLDS, DRAIN LINES, SHUT-OFFS, GREASE
TRAPS & BACKFLOW PREVENTORS AS REQUIRED BY EQUIPMENT AND/OR LOCAL CODES.
ALL KITCHEN, DINING ROOM AND BAR AREA WASTES ARE TO BE OPEN SITE IN FLOOR,
UNLESS OTHERWISE SPECIFIED.
9.
IF WATER PRESSURE AT EQUIPMENT AREA EXCEEDS 40 P.S.I. FLOW PRESSURE, INSTALL A
PRESSURE REDUCING VALVE ON BOTH THE MAIN HOT AND COLD WATER SUPPLY LINES.
10.
LOCATE AND FURNISH ALL AREA FLOOR DRAINS UNLESS OTHERWISE SPECIFIED.
11.
PROVIDE AND SIZE ANY SOFTENING AND FILTERING EQUIPMENT THAT MAY BE REQUIRED
UNLESS OTHERWISE SPECIFIED.
12.
DETERMINE SIZE OF GAS SUPPLY LINE REQUIRED FOR ALL GAS EQUIPMENT INCLUDING
FOOD SERVICE EQUIPMENT.
13.
PLUMBER TO PROVIDE AND INSTALL BACKFLOW PREVENTORS ON ALL EQUIPMENT AS
REQUIRED BY LOCAL CODE.
14.
SEE EQUIPMENT SCHEDULE FOR LISTING OF ALL EQUIPMENT WITH APPOPRIATE
SPECIFICATIONS. SCHEDULE WILL INCLUDE ALL RESPONSIBLITIES FOR PROVIDING AND
INSTALLING EQUIPMENT.
15.
THESE PLANS ARE FOR INFORMATION ONLY. INFORMATION ON THIS SHEET IS TO BE
REVIEWED BY THE OWNER AND INCORPORATED INTO THE BUILDINGS' MECHANICAL PLANS IN
ACCORDANCE WITH LOCAL CODES. THE ENTIRE INSTALLATION SHALL CONFORM WITH THE
LATESET EDITION OF THE LOCAL AND STATE PLUMBING CODE IN ADDITION TO LANDLORD
REQUIREMENTS AND SPECIFICATIONS.
16.
THE OWNER SHOULD SUBMIT THESE PLANS TO LOCAL BUILDING, HEALTH AND FIRE
DEPARTMENT OFFICIALS FOR APPROVAL.
17.
CONTRACTORS TO MAKE USE OF ANY CONNECTIONS ALREADY INSTALLED IN EXISTING
BUILDING WHENEVER POSSIBLE.
18.
CONTRACTORS TO PROVIDE AND INSTALL WALL BACKING FOR WALL SHELVES. WALL
MOUNTED HANDSINKS, WALL MOUNTED COOKING EQUIPMENT, ETC. VERIFY THESE
LOCATION WITH OWNER.
19.
FLOOR DRAINS AND/OR FLOOR SINKS SHOWN ARE RECOMMENDED LOCATIONS,
MECHANICAL ENGINEER TO VERIFY CODE REQUIREMENTS
PIPING VALVES:
GENERAL
PLUMBING CONTRACTOR TO PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY
FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION. INSTALL VALVES FOR EACH
FIXTURE AND ITEM OF EQUIPMENT. PROVIDE BRAIDED STAINLESS STEEL HOSE (UNLESS
OTHERWISE NOTED) BETWEEN VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT FOR EASY ACCESS SUCH
THAT VALVES CAN BE REACHED WITHOUT MOVING EQUIPMENT.
PIPE SIZE
INSULATION THICKNESS
1
LESS THAN OR EQUAL TO 12"
1"
2" DIA. OR GREATER
121"
2
(INSULATION VALUE = k VALUE NOT EXCEEDING .027 BTU PER
INCH/h*ft *f
SAFETY COVERS
INSTALL SPECIFIED NO-SCALD SAFETY COVERS WITH INSULATED FOAM LINER AND TAMPER
PROOF STRAP AT ALL EXPOSED PIPING.
NOTE
ALL PLANNING AND DESIGNING OF PLUMBING SYSTEMS SHALL BE PERFORMED ONLY BY
LICENSED PLUMBERS OR A LICENSED DESIGN PROFESSIONAL.
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
VALVES
PROVIDE VALVES FOR WORKING PRESSURE IN WATER PIPING OF 125 PSI OR GREATER. UNLESS
NOTED OTHERWISE VALVES SHALL BE AS FOLLOWS:
VALVE TYPE
MANUFACTURER MODEL NO. CHECK VALVE (UP TO 2")
NIBCO
#S-22 FULL PORT BALL VALVE (UP TO 3")
NIBCO
#S-FP-600
GATE VALVE (UP TO 3")
NIBCO
#S-113
TEMP. AND PRESSURE RELIEF VALVE WILKINS
#TP1100A
WATER HAMMER ARRESTOR
WILKINS
#1250
BACKFLOW PREVENTER (WHOLE-HOUSE) WILKINS
#950XLU BACKFLOW PREVENTER (SINGLE
DEVICE) WILKINS
#700
VACUUM RELIEF VALVE
WILKINS
#35VCH PRESSURE REDUCING VALVE
WILKINS
#500YSBR
TRAP SEAL PRIMER
JAY R. SMITH #2699-1
SUPPLY
IF WATER PRESSURE SUPPLIED TO STORE IS GREATER THAN AND 65 PSI. THEN PROVIDE A
PRESSURE REGULATOR TO MAIN SUPPLY TO MAINTAIN WATER PRESSURE. PROVIDE BACKFLOW
PREVENTION ON WATER SERVICE IF REQUIRED BY LOCAL CODES.
WATER PIPING
PROVIDE THERMAL INSULATION ON ALL HOT TEMPERED & COLD WATER, AND HORIZONTAL
WASTE PIPING IN CEILING SPACES, AND ON ALL COLD WATER PIPING IN CASEWORK AND BAR
AREAS. USE SELF-SEALING CLOSED CELL FOAM OR JACKETED FIBERGLASS INSULATION WITH
MANUFACTURE APPROVED ADHESIVES, SEALERS, AND COATINGS. ALL MATERIALS USED SHALL
NOT EXCEED 25 FOR FLAME SPREAD, 50 FOR FUEL CONTRIBUTED, OR 50 FOR SMOKE DEVELOPED.
UNLESS OTHERWISE REQUIRED BY THE LOCAL AUTHORITY OR ENERGY CODES, THE MINIMUM
INSULATION LEVELS SHALL BE AS FOLLOWS:
RAIN CONDUCTORS
INSULATE RAIN WATER CONDUCTORS WHICH PASS THROUGH OCCUPIED AREAS WITH 21" THICK
FIBERGLASS.
KITCHEN EQUIPMENT ITEM NUMBERADDITIONAL INFORMATIONS
1.
PIPING INSULATION:
HVAC PIPING
INSULATE REFRIGERANT SUCTION PIPING AND COOLING COIL CONDENSATE PIPING 34" THICK, SELF
SEALING, CLOSED CELL FOAM. INSULATE HVAC HOT AND WITH CHILLED WATER PIPING SYSTEMS
AND LOW PRESSURE STEAM AND CONDENSATE PIPING WITH 121" THICK, HEAVY DUTY, SELF
SEALING, JACKETED FIBERGLASS.
WASTE
FS.
TESTING
ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY ARE BACKFILLED OR
CONCEALED. AFTER TESTING IS COMPLETE, THE PLUMBING CONTRACTOR SHALL DISINFECT THE
POTABLE WATER SYSTEM AS REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING
TO LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO ENGINEER FOR REVIEW AND
APPROVAL.
ICE BIN DRAIN
INSULATE ICE BIN COPPER DRAIN LINES WITH 21" THICK, SELF-SEALING, SECTIONAL, CLOSED CELL
FOAM.
VENT THRU ROOF
W
INSTALLATION
INSTALL EXPOSED PIPING FREE OF SAGS AND BENDS. PROVIDE BRACKET STANDOFFS FROM
MOUNTING SURFACES SUFFICIENT TO ALLOW 1" CLEANING SPACE AROUND ALL PIPING,
INCLUDING ANY ADDED PIPING INSULATION. INSTALL FITINGS FOR CHANGES IN DIRECTION AND
BRANCH CONNECTIONS. INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND
MASONRY WALLS, GYPSUM BOARD PARTITIONS, CONCRETE FLOOR AND ROOF SLABS. SEAL PIPE
PENETRATIONS THROUGH RATED CONSTRUCTION WITH FIRESTOPPING SEALANT MATERIAL.
UNDERGROUND WATER AND SEWER LINES SHALL BE LAID IN SEPARATE TRENCHES WITH A
MINIMUM HORIZONTAL SPACING AS REQUIRED BY CODE, EXCAVATED TO THE PROPER DEPTH AND
GRADED TO PRODUCE THE REQUIRED FALL.
NATURAL GAS PIPING
GAS PIPING SHALL BE SCHEDULE 40, SEAMLESS, BLACK STEEL PIPE. PROVIDE PIPING SUPPORT
BLOCKING ON ROOF, COMPATIBLE WITH ROOFING SYSTEM.
LINE SIZE BALANCING VALVE
AFF
PIPING (CONTINUED):
A
R
4 0 4 S.
C
H
Wells
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
MISC. PLUMBING FIXTURES:
GREASE INTERCEPTOR
LANDLORD PROVIDED EXTERIOR GREASE INTERCEPTOR.
PROJECT NUMBER: 16-059
PIPING:
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
PLUMBING SYMBOLS LEGEND
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
PLUMBING
LEGEND AND
NOTES
SHEET NUMBER
P1.0
GENERAL NOTES
DESIGNATION
EQUIPMENT
DOMESTIC WATER
GWH
WATER HEATER
MBH
SUB-TOTAL
PLUMING FIXTURE
WATER FIXTURE UNITS
TOTAL WATER FIXTURE UNITS
199
WATER CLOSET
10
2
20
199
LAVATORIES
2
2
4
RTU-1
ROOF TOP UNIT
250
HAND SINKS
2
2
4
RTU-2
ROOF TOP UNIT
250
MOP SINK
3
1
3
500
PREP SINK
3
1
3
SHAKE STATION
2
1
2
SODA SYSTEM/ICE MACHINE
1
1
1
3-COMPARTMENT SINK
3
1
3
BUILDING HEATING
SUB-TOTAL
TOTAL NATURAL GAS CONNECTED LOAD
699
MBH CAPACITY
GAS METER REQUIREMENTS
NUMBER OF FIXTURES
TOTAL DEVELOPED LENGTH INCLUDING EQUIVALENT
PIPE LENGTH FOR FITTING AND VALVE FRICTION
LOSSES TO GAS METER.
75 FT X 1.2=
90 FT
6 14
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR
AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL
LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS.
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR
INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET
THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER
BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES
AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE
WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR
SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN
GOVERNING CODES AND DESIGN INTENT.
WATER PIPE SIZE= 2"
5
FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING AND START OF WORK.
FIELD VERIFY ALL CONDITIONS
40
TOTAL WATER FIXTURE UNITS
CONSULT GAS UTILITY COMPANY FOR REGULATOR RATING
2
B
9
7
13
2
1
WATER PIPING - POINT OF CONNECTION TO LANDLORD PROVIDED 2" CW TO SPACE. VERIFY
EXACT LOCATION IN FIELD PRIOR TO WORK. CONTACT ENGINEER WITH ANY DISCREPANCIES.
2
EQUIPMENT WATER CONNECTIONS - PROVIDE AN RPZ OR BACKFLOW PREVENTION ON ALL
DIRECT WATER SUPPLY LINES TO EQUIPMENT.
3
LAVATORY - 1/2" CW AND TW DOWN IN WALL TO LAVATORY.
4
WATER CLOSET - 1" CW DOWN IN WALL TO WATER CLOSET. PROVIDE WATER HAMMER
ARRESTOR PRIOR TO FINAL CONNECTION (PDI TYPE "B").
5
DIPPERWELL - 1/2" CW DOWN IN WALL TO DIPPERWELL.
15
BACKFLOW PREVENTOR - 1/2" CW DOWN IN WALL TO BACKFLOW PREVENTOR. BRANCH 1/2"
CW TO ICE MACHINE, 1/4" CW TO TEA BREWER, AND BAG-N-BOX.
7
PREP SINK - 3/4" CW & HW DOWN IN WALL TO PREP SINK FAUCET.
8
3-COMPARTMENT SINK - 3/4" CW AND HW DOWN IN WALL TO 3-COMPARTMENT FAUCET.
9
SHAKE STATION & RINSER - 1/2" CW & HW DOWN IN WALL TO SHAKE STATION FAUCET.
10
BAG-N-BOX - 1/2" CW DOWN IN WALL TO BAG-N-BOX.
11
MOP SINK - 3/4" CW AND HW DOWN IN WALL TO MOP SINK FAUCET.
12
WATER HEATER - 1" CW DOWN AND 1" 140° HW UP FROM WATER HEATER MOUNTED ON WATER
HEATER STAND.
13
HAND SINK - 1/2" CW AND TW DOWN IN WALL TO HAND SINK.
14
TEA BREWER - 1/4" CW DOWN IN WALL TO TEA BREWER.
15
DO NOT ROUTE ANY WATER PIPING OVER ELECTRICAL PANELS OR TRANSFORMERS.
16
ROUTE LOW PRESSURE GAS PIPING DOWN THROUGH ROOF TO CONNECT TO GAS WATER
HEATER. PROVIDE 6" DIRTLEG AND SHUTOFF PLUG VALVE PRIOR TO FINAL CONNECTION.
VERIFY SIZE AND LOCATION IN FIELD.
17
ROUTE GAS TO NEW TENANT PROVIDED GAS METER. NEW METER'S DEMAND= 699 CFH,
(FIELD VERIFY ACTUAL LOCATION) CONTRACTOR TO TENANT PROVIDED METER. DELIVERY
PRESSURE: 7 IN W.C. APPROXIMATE LENGTH TO METER BANK 90'-0". CONTRACTOR TO
VERIFY EXACT LENGTH AND LOCATION IN FIELD. VERIFY METER REQUIREMENTS WITH
GAS COMPANY PRIOR TO WORK.
18
PROVIDE RECIRCULATING PUMP. BELL AND GOSETT NRF-22. 115V, 2940 RPM. PROVIDE
WITH AQUASTAT.
19
CONTRACTOR PROVIDED RPZ - 1-1/2" CW DOWN IN WALL TO REDUCED PRESSURE ZONE
BACKFLOW PREVENTOR (WATTS LF919QT OR EQUAL) AND TENANT PROVIDED WATER
SUBMETER MOUNTED ON WALL.
20
CONDENSATE DRAIN DOWN FROM COOLER, FREEZER AND/ OR RTU'S DOWN INTERIOR WALL,
DRAIN INDIRECTLY TO FLOOR DRAIN.
21
1" CONDENSATE DOWN FROM ROOFTOP UNITS ABOVE CEILING AND ROUTED AS HIGH AS
POSSIBLE AS SHOWN.
22
ROUTE LOW PRESSURE GAS PIPING ON ROOF AS REQUIRED TO CONNECT TO GAS FIRED
RTU'S. PROVIDE 6" DIRT LEG AND SHUT OFF PLUG VALVE PRIOR TO FINAL CONNECTION.
23
CONDENSATE DRAIN PIPING IN FREEZER, PROVIDE TYPE "L" COPPER CONDENSATE DRAIN
PIPING WITH 1-1/2" THICK FIBERGLASS INSULATION OVER ELECTRICAL HEAT TRACE (SUPPLIED
AND INSTALLED BY ELECTRICAL CONTRACTOR) SEE ELECTRICAL DRAWINGS. PVC
CONDENSATE DRAINS INSIDE COOLERS, FROM EVAPORATOR COILS, SLOPE 2% AND HOLD
TIGHT TO COOLER WALL. ALL SURFACE MOUNTED PIPING SHALL BE INSTALLED ON 1" SPACER
TO ALLOW FOR CLEANING.
20
3
21
22
23
22
1
4
4
12
11
R
4 0 4 S.
6
17
6 10
A
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
S
0334
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
19
18
R
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
W.H.
23
E
955
ILLINOIS DESIGN FIRM # 184.006688
8
13
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
PROJECT NUMBER: 16-059
SYSTEM
A
REFER TO SCHEDULES, DETAILS AND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING OF
PIPING TO EQUIPMENT.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
TABLE TO CALCULATE WATER FIXTURE UNITS
GAS LOAD SUMMARY
KEYNOTES
16
SHEET TITLE
PLUMBING
SUPPLY &
SCHEDULES
SHEET NUMBER
P2.0
PLUMBING GENERAL NOTES:
NUMBER OF FIXTURES
POINT OF CONNECTION TO EXISTING SANITARY WASTE PIPING. VERIFY EXACT SIZE,
INVERT ELEVATION AND LOCATION IN FIELD PRIOR TO WORK. CONTACT ENGINEER IF ANY
DISCREPANCIES ARE DISCOVERED.
2
2" WASTE DN AND 2" VENT UP IN WALL FROM SINK OR LAVATORY
D P.C. TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH VENDOR AND/OR OWNER. ADJUST
PLUMBING LOCATIONS AS NECESSARY.
3
3" WASTE DN AND 2" VENT UP IN WALL FROM FLOOR DRAIN/SINK.
4
4" WASTE DN AND 2" VENT UP IN WALL FROM WATER CLOSET.
5
3" WASTE DN AND 2" VENT UP IN WALL FROM MOP SINK
6
INDIRECT WASTE WITH 2" GAP FROM 3 COMPARTMENT SINK TO FLOOR SINK.
7
INDIRECT WASTE WITH 2" GAP FROM PREP SINK TO FLOOR SINK
8
INDIRECT WASTE WITH 2" GAP FROM DIPPERWELL AND SINK TO FLOOR SINK
9
INDIRECT WASTE WITH 2" GAP FROM ICE MACHINE AND/OR TEA BREWER TO FLOOR SINK/
DRAIN.
B FIELD VERIFY ALL CONDITIONS PRIOR TO BIDDING AND START OF WORK.
TOTAL DRAINAGE FIXTURE UNITS
C VERIFY LOCAL PLUMBING AND HEALTH DEPT. DRAIN REQUIREMENTS FOR THE
3-COMPARTMENT SINK, PREP SINK, AND SHAKE SINK.
WATER CLOSET
10
2
20
LAVATORIES
2
2
4
HAND SINKS
2
2
4
FLOOR DRAINS
3
6
18
FLOOR SINKS
5
4
20
E G.C. TO PROVIDE ACCESS FOR SODA LINES IF NECESSARY. COORDINATE WITH VENDOR
AND/OR OWNER.
MOP SINK
3
1
3
F. ALL FLOOR DRAINS TO INCLUDE TRAP PRIMERS WITH BACKFLOW PREVENTER.
TOTAL DRAINAGE UNITS = 69
FIELD VERIFY ALL CONDITIONS
A
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING
OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL
INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING
CONDITIONS.
NOTE:
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING
FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS
TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER
AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND
ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT
ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING.
THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT
DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
3
3
8
2
3
7
2
3
6 13
10
9
11
10
3 12
1
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
14
2
R
4 0 4 S.
10
3" WASTE DOWN FROM FLOOR DRAIN/ FLOOR SINK.
11
ROUTE TO CONNECT TO EXISTING LANDLORD PROVIDED EXTERIOR GREASE INTERCEPTOR.
VERIFY EXACT INSTALLATION REQUIREMENTS WITH MANUFACTURER IN FIELD PRIOR TO ANY
WORK.
12
CONDENSATE FROM COOLER, FREEZER AND RTU'S TO DISCHARGE INDIRECTLY INTO FLOOR
DRAIN AT A SLOPE NOT LESS THAN 1/8" PER FOOT. PROVIDE MINIMUM 1" AIR GAP FROM LIP OF
BASIN. PROVIDE WITH 7" FUNNEL.
13
FLOOR SINK AT 3-COMP SINK TO ALIGN WITH RIGHT SIDE BASIN. SEE DETAIL 03/P6.0.
14
POINT OF CONNECTION TO EXISTING VENT PIPING.
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
ISSUE DATE
1
ISSUE
DD SET
95% SET
3
4
4
3
S
0334
PROJECT NUMBER: 16-059
DRAINAGE FIXTURE UNITS
1
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
A REFER TO SCHEDULES, DETAILS AND RISER DIAGRAMS FOR MORE INFORMATION ON SIZING
OF PIPING TO EQUIPMENT.
TABLE TO CALCULATE DRAINAGE FIXTURE UNITS
PLUMING FIXTURE
KEYNOTES:
DATE
04-26-2016
05-23-2016
1
W.H.
10
5
SHEET TITLE
PLUMBING
WASTE
PLAN
SHEET NUMBER
P3.0
DESCRIPTION
MANUFACTURER
MODEL #
Count
FINISH
FURN.
INSTALL
P102
WATER CLOSET-FLO WISE WITH AUTOMATIC FLUSH
AMERICAN STANDARD
MADERA FLOWISE 3249.001, ELOGATED BOWL; PROVIDE 6067
HARD WIRED SELECTRONIC FLUSH VALVE (P104)
2
WHITE
GC
GC
P201
THREE COMPARTMENT SINK
ELKAY
3C16X20 - 2 - 18X, 20"D X 88"L, 10"H REAR SPLASH, LEFT & RT
HAND 18" DRAINBOARDS
1
SS
VD
GC
P204
STAINLESS STEEL WORKTABLE W/ SINK - PREP TABLE
ELKAY
SLWT30X84BS
1
SS
VD
P205
MOP SINK W/ FAUCET
FIAT
MOLDED STONE INTEGRAL DRAIN MSBID2424 W/ 830AA
SERVICE FAUCET
1
WHITE
P206
FLOOR SINK
SIOUX MANUFACTURING
861-23X W/ HALF GRATE 861-52i
P208
FLOOR DRAIN
SIOUX MANUFACTURING
P210
WALL-HUNG LAVATORY
AMERICAN STANDARD
VOLTS
PLUMBING SCHEDULE
WATTS
AMP
PLUG
HW. SUPPLY CW. SUPPLY
TW. SUPPLY
WASTE
VENT
PROVIDE WITH 5905.100 HEAVY DUTY AMERICAN STANDARD SEAT, FLUSH VALVE #6065.121.002 PROVIDE JBOX IN WALL WITH LOW VOLTAGE
POWER.
1"
4"
3/4"
3/4"
(3) 2"
INDIRECT WASTE, SEE ITEM #P600 FOR FAUCET
GC
3/4"
3/4"
1-1/2"
PROVIDE FLOOR SINK W/ INDIRECT WASTE CONNECTION. SEE ITEM #P601 FOR FAUCET
GC
GC
1/2"
1/2"
3"
2"
4
GC
GC
3"
2"
842-3-P-NQ
6
GC
GC
3"
2"
LUCERNE 0355.012
2
VD
GC
WHITE
2"
COMMENTS
1/2"
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
VACUUM BREAKER
PROVIDE DEEP SEAL TRAPS, ADD VEGETABLE OR MINERAL OIL TO TRAP
SEE ITEM #P611 FOR FAUCET. PROVIDE TEMPERING VALVE.
A
R
4 0 4 S.
HAND SINK
ELKAY
SEHS-17X - 17"L X 15"W X 5"D W/ SIDE SPLASHES
2
P215
SHAKE STATION (RIGHT HAND VERSION)
ELKAY
CUSTOM BACK BEVERAGE COUNTER
P401
CHEMICAL DISPENSER
CHEMICAL DISPENSER
P405
HOSE BIB
P406
SS
VD
GC
1/2"
1
VD
VD
1/2"
PROVIDE TEMPERING VALVE
1629WML/1629WMR
2
VD
VD
1/2"
CONTAINS ALUMINUM CLORIDE. PROVIDE STAINLESS STEEL DOUBLE CHECK BACKFLOW PREVENTOR
WOODFORD
MODEL 17CC
1
GC
GC
ANTI-SIPHON FREEZLESS
TEMPERING VALVE
LEONARD
220
4
GC
GC
PROVIDE AT EACH HAND SINK AND LAVATORY, SET TO 100° F
P408
BUILT-IN DIPPERWELL
T&S BRASS
006678-45 W/ B2282-F03
1
SS
VD
VD
P409
RINSER
BLENDTEC
JRE-610 LITTLE BLACK RINSER
1
SS
VD
VD
P410
TEA BREWER
BUNN
TB3Q
1
VD
VD
P600
3 COMP SINK FAUCET
T&S BRASS
B-0230-LN FAUCET; 064X 16" SWING NOZZLE W/ STREAM
REGULATOR
1
VD
GC
1/2"
1/2"
P601
PREP TABLE SINK FAUCET
T&S BRASS
B-0225-LN FAUCET; 135X 12" SWIVEL GOOSENECK
1
VD
GC
1/2"
1/2"
P603
HAND SINK FAUCET
T&S BRASS
B-1115-LN FAUCET; 131X SWING GOOSENECK; 1136-45 TEFLON
SEAT WASHERS
2
BRONZE
VD
GC
1/2"
1/2"
P605
SPRAYER NOZZLE
T&S BRASS
B-0133 W/ 063X, B-0155-LNEZ & B-0970-FEZ
1
CHROME
VD
GC
1/2"
P610
SHAKE STATION FAUCET & TEMPERING VALVE
T&S BRASS
B-0306
1
CHROME
VD
VD
1/2"
P611B
LEVER LAVATORY FAUCET-4" SPREAD
MOEN
8413SP
2
CHROME
VD
VD
1/2"
P702
WALK-IN COOLER/FREEZER - END DOOR
KOLPAK
CUSTOM
1
VD
GC
P704
SODA/ICE DISPENSER
CORNELIUS
IDC255
1
VD
VD
120/60
9.3
3/8"
3/4"
P707
ICE MAKER AT SODA MACHINE- AIR-COOLED
HOSHIZAKI AMERICA, INC.
KML-451MAH
1
VD
VD
115/60/1
10.3
1/2"
3/4"
P715
COOLER REFRIGERATION SYSTEM - REMOTE
COOLER
KOLPAK
POLAR PAK
1
VD
GC
208-230/60/1
ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY
EQUIPMENT VENDOR
P716
COOLER REFRIGERATION SYSTEM - REMOTE
FREEZER
KOLPAK
POLAR PAK
1
VD
GC
208-230/60/1
ALLOWS CONDENSOR TO BE LOCATED ON THE ROOF OR OUTSIDE TO REDUCE HEAT INSIDE STORE; REFRIGERATION HOOK-UP BY
EQUIPMENT VENDOR
P800
GAS WATER HEATER
BRADFORD WHITE OR EQUAL
EF-60T-199
1
GC
GC
120/1
P804
ICE MAKER CONNECTION HOSE
DORMONT MANUFACTURING
W37B2Q48
1
VD
GC
P805
LEVER TWIST WASTES
T&S BRASS
B-3950
2
VD
GC
P807
WATER HEATER STAND
NATIONAL HOT WATER
PK101
1
GC
GC
SS
1/2"
1/2"
1-1/2"
1 1/2"
1-1/2"
SEE ITEM #P603 FOR FAUCET. PROVIDE TEMPERING VALVE.
FAUCET INCLUDED
H
S t .,
I
T
E
Suite
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
120/1/60
1780
14.8
NEMA 5-1SP
1/4"
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
PROVIDE TEMPERING VALVE
8" WALL MOUNT FAUCET, ADD-ON FAUCET W/ 8" SWING NOZZLE, CERAMIC CARTRIDGES, COMPACT SPRING & FLEX HOSE, B-0107-C SPRAY
VALVE, VACUUM BREAKER & 6" WALL BRACKET & LEVER HANDLES
USE FOR NEW STORES
1/2"
REFRIGERATION HOOK-UP BY EQUIPMENT VENDOR
1.8
1"
mechanical
electrical
plumbing
fire protection
structural
1"
STANDARD AIR COOLED UNIT
REFER TO INSTALLATION GUIDE FOR MORE INFORMATION, EXPANSION TANK TO BE PROVIDED.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
P211
C
Wells
PROJECT NUMBER: 16-059
ITEM #
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
PLUMBING
SCHEDULE
SHEET NUMBER
P4.0
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
PROJECT NUMBER: 16-059
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
mechanical
electrical
plumbing
fire protection
structural
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
PLUMBING
RISERS
SHEET NUMBER
P5.0
HOT WATER RETURN TO WATER HEATER.
COLD WATER SUPPLY TO WATER HEATER.
HOT WATER TO FIXTURES
AS SHOWN ON PLANS
PROVIDE FULL PORT BALL SHUT-OFF VALVES
PROVIDE PIPE UNIONS, DIELECTRIC IF
REQUIRED FOR DISSIMILAR METALS.
DRAIN LINE
RESTROOM
LAVATORY
MOUNT 1"
ABOVE FLOOR
FINISHED FLOOR
(SEE
ARCHITECTURAL
FOR FLOOR
SLOPES)
AIR GAP = 2 X "d"
STOP VALVE
TURN TRAP PRIMER
DRAIN LINE INTO WALL
TYPE 'K' COPPER TUBING
- NO JOINTS BELOW FLOOR
SILICONE BEAD
BOLT STRAPS TO SOLID BLOCKING IN WALL WITH 3/8"Ø X
2-1/2" LAG BOLTS, TYPICAL OF FOUR (4)
1/2" DIAMETER THINWALL (EMT)
CONDUIT WITH ENDS FLATTENED
TRAP PRIMER WITH CHROME
FINISH PPP#PROI-ULP500
WITH DU-4
COLD WATER
3/4" x 24 GUAGE PERFORATED
PLUMBERS TAPE
GAS-FIRED WATER HEATER
PER SPECS AND SCHEDULE.
PROVIDE A 210° F ASME APPROVED TEMPERATURE AND 150 PSI
PRESSURE RELIEF VALVE WITH TEST LEVER, SIZED WITH CAPACITY
PER WATER HEATER MANUFACTURER'S RECOMMENDATIONS.
G
WH
PROVIDE A HARD COPPER RELIEF VALVE DISCHARGE LINE FULL
SIZE OF VALVE OUTLET TO END OVER JS WITH 6" AIR GAP.
BURNER THERMOSTAT AND PRESSURE REGULATOR FURNISHED WITH WATER HEATER.
SET WH ON PLATFORM (PLATFORM BY OTHERS)
ROUTE P&T VALVE TO TERMINATE INTO MOP SINK
Scale: N.T.S.
7
8" MINIMUM, 24" MAXIMUM
HIGH STRAINER POSTION
FLR DRAIN SET BELOW TOP OF
FIN FLR. ADJACENT TILE
CANTS TO CREATE DIMPLE
3/4" x 24 GUAGE PERFORATED
PLUMBERS TAPE
12
THIN SET CERAMIC
TILE, TYP
UNION
CLEANOUT PLUG AND
BODY. SEE SPECS.
MOISTURE BARRIER
11 4"
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
BALL VALVE
BALL VALVE
CHECK VALVE
RISER
STRAINER
1/8 BEND FULL
SIZE, 4" MAX.
FLEXIBLE CONNECTION
2 REQUIRED
mechanical
electrical
plumbing
fire protection
structural
Scale: N.T.S.
BELL & GOSSETT NRF-22
PLUG IF END OF LINE
FLOW
4"
ISSUE DATE
2
FLOOR DRAIN
Scale: N.T.S.
5
FLOOR CLEANOUT
Scale: N.T.S.
8
CIRCULATING PUMP DETAIL
Scale: N.T.S.
10
NOT USED
Scale: N.T.S.
13
NOT USED
Scale: N.T.S.
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
3-COMPARTMENT
POT SINK
2"OUTLET
(TYPICAL)
3"
CO.
FLOOR SINK
3"
4"
SHEET TITLE
PLUMBING
DETAILS
POINT OF CONNETION TO EXISTING
GREASE WASTE. VERIFY IN FIELD.
EXISTING EXTERIOR LANDLORD PROVIDED GREASE INTERCEPTOR
SHEET NUMBER
VERIFY EXACT EXTERIOR LOCATION IN FIELD
3
3 COMPARTMENT SINK WITH GREASE INTERCEPTOR
Scale: N.T.S.
S
0334
NOT USED
WIRING BY ELECT.
CONTRACTOR
ADJUSTING COLLAR
C
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
Scale: N.T.S.
FIN. FLOOR
5" SQ
E
300
2'-6" MAX.
WATER HEATER
CAULK JOINT
8-3/8"
T
Suite
St. Louis - Montreal
COVER
LOW STRAINER POSITION
I
S t .,
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
Scale: N.T.S.
H
1/2" DIAMETER THINWALL (EMT)
CONDUIT WITH ENDS FLATTENED
PIPING SHOWN IS SCHEMATIC. PROVIDE CLEARANCES
RECOMMENDED BY MANUF., SEISMIC STRAPPING. SET
THERMOSTAT AT 140°F.
TRAP PRIMER DETAIL
C
Wells
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
DRAIN VALVE BY HEATER MANUFACTURER
6" LONG DIRT LEG
PROVIDE WATER- TIGHT GALVANIZED SHEET
METAL PAN 2" DEEP WITH 1" DRAIN PIPE TO JS
PIPE
4
R
4 0 4 S.
ILLINOIS DESIGN FIRM # 184.006688
GAS SHUT-OFF COCK WITH LEVER
HANDLE & GROUND JOINT UNION
FLOOR DRAIN WITH TRAP
PRIMER CONNECTION
FLOOR SINK
A
4" PVC EXHAUST
LIFT OUT ALUMINUM
SEDIMENT BUCKET
1
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
4" PVC AIR INLET
PROJECT NUMBER: 16-059
"d"
FLOOR GRATE
RECIRCULATING PUMP
THERMOMETER
NOTE:
ALL EXPOSED PIPING SHALL
BE CHROME PLATED
"d"
EXPANSION TANK
9
NOT USED
Scale: N.T.S.
11
NOT USED
Scale: N.T.S.
14
NOT USED
Scale: N.T.S.
P6.0
DESCRIPTION
VAC/PH
LOAD
HAFF
24HR.
REMARKS
CIRCUIT(S)
E103
COOLER LIGHTS AND SWITCH
120/1
1.6
A
78 in.
X
A,J,K,R
RP-34
E103A
DOOR HEATER
120/1
1.47
A
72 in.
X
A,K
RP-12
E105
REFRIGERATED FRONT LOAD STATION
120/1
8.6
A
18 in.
X
D,H
LP-2
E106
REFRIGERATED DRESS STATIONS -(FRONT)
120/1
4.9
A EA.
18 in.
X
D,H
LP-6 & LP-8
E106
REFRIGERATED DRESS STATIONS - (BACK)
120/1
4.9
A EA.
44 in.
X
D,H
LP-16
E107
REFRIGERATE SALAD STATION - (FRONT)
120/1
5.5
A
18 in.
X
D,H
LP-10
E107
REFRIGERATE SALAD STATION - (BACK)
120/1
5.5
A
44 in.
X
D,H
LP-14
E128
ICE CREAM DIPPING CABINET
120/1
8.0
A
44 in.
X
D, H
RP-37
E130
UNDER COUNTER REFRIGERATOR (SHAKE STATION) 120/1
3.9 A
18 in.
X
D,H
LP-26
E131
FUTURE EQUIPMENT
120/1
1
A
44 in.
X
D,H
LP-7
E302
MEATBALL WARMER
120/1
13.3
A
18 in.
D,H
RP-15
E302A
SOUP WARMER
120/1
13.3
A
D,H
LP-12
E304
CONVEYOR OVEN
208/3
40.0
A
E401
SLICER
120/1
7.0
A
45
in.
D,H
RP-25
E404
FAX MACHINE
120/1
4.0
A
44
in.
D,E,H
LP-28
E406
P.O.S EQUIPMENT
120/1
2.0
A EA.
E,F,H,T
LP-1
E427
BLENDER
120/1
15.0
A EA.
18
in.
D,H
LP-33 & LP-35
E408
FUTURE EQUIPMENT (BRISKER)
120/1
5.0
A
74
in.
D,H
LP-20
E409A
CARBONATORS
120/1
4.0
A
91 in.
D,E,H
RP-32
M109
FUTURE EQUIPMENT
120/1
15.0
P102
AUTOMATIC FLUSH VALVE
120/1
X
P410
TEA BREWER
120/1
14.0
A
18
in.
D,H
RP-24
P704
SODA/ICE DISPENSERS
120/1
9.3
A
18
in.
D,E,H
LP-18
P707
ICE MAKER
120/1
19.9
A
24
in.
P715
REMOTE COOLER CONDENSER
208/230/1
7.4
A
P715
REMOTE COOLER BLOWER
115/1
1.8
A
A,T,S
JBOX @ 23"CL IN DIEWALL
45
A EA.
A
in.
REFER TO CUT SHEET
P716
REMOTE FREEZER CONDENSER
208/230/1
12.6
A
P716
REMOTE FREEZER BLOWER
208/230/1
5.7
A
P800
GAS WATER HEATER
120/1
1.8
A
P410
18 in.
SEE DETAIL 7/E7.0
ON ROOF
ON ROOF
100
P704
E130
P707
E131
in.
D
RP-22
RP-40
X
C,D,E,H
LP-29,31
X
C
LP-22,24
X
C
LP-30
X
C
RP-28,30
X
C
RP-39,41
X
C,E
FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
1
ELECTRICAL EQUIPMENT:
SEE RISER DIAGRAM AND SCHEDULES, SHEET E6.0 & E7.0.
A.
WIRE TO JUNCTION BOX ON EQUIPMENT.
B.
ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
HVAC EQUIPMENT:
SEE ELECTRICAL CONNECTION SCHEDULE, SHEET E6.0.
B.
ATTACH RECEPTACLE OR J.B. TO COUNTER OR EQUIPMENT.
2
C.
WIRE TO EQUIPMENT. PROVIDE DISCONNECT OR CORD AND PLUG AS REQUIRED BY LOCAL
CODE.
D.
PROVIDE RECEPTACLE FLUSH IN WALL.
E.
EQUIPMENT NOT SUPPLIED BY K.E.C., VERIFY REQUIREMENTS WITH SUPPLIER.
F.
DEDICATED CIRCUIT/ISOLATED GROUND, PROVIDE ELECTRICAL OUTLET. PROVIDE CONDUIT
ACCESS FOR COMMUNICATION CABLE,
G.
VERIFY WITH OWNER. PROVIDE AND INSTALL CORD & PLUG AND RECEPTACLE.
H.
EQUIPMENT SUPPLIED WITH CORD & PLUG.
C.
D.
REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL
DEVICES.
THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL VOLTAGE
REQUIREMENTS ON ALL EQUIPMENT.
HVAC RECEPTACLE:
PROVIDE RECEPTACLE MOUNTED ADJACENT TO EQUIPMENT. CONNECT TO CIRCUIT RP-2.
5
RECIRCULATION PUMP
PROVIDE 20A, 120V OUTLET FOR RECIRCULATION PUMP, COMPLETE ALL FINAL ELECTRICAL
CONNECTIONS.
6
MANAGER'S DESK:
SEE DETAIL 3/E7.0 FOR ALL OUTLET AND CIRCUITING REQUIREMENTS.
ELECTRICAL CONTRACTOR TO VERIFY LOCATIONS OF SODA EQUIPMENT WITH OWNER AND/OR
SODA VENDOR. ADJUST ELECTRICAL LOC. AS NECESSARY.
7
FLY LIGHT
PROVIDE AND OUTLET AT 9'-0" AFF FOR THE FLY LIGHT.
I.
ALL KITCHEN 125 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES SHALL BE GFCI TYPE PER
NEC SECTION 210.8 (B).F.
8
SHOW WINDOW RECEPTACLES
PROVIDE DUPLEX RECEPTACLE MOUNTED ABOVE WINDOW FOR SHOW WINDOW REQUIREMENTS,
AS REQUIRED BY THE NEC
J.
ALL GFCI RECEPTACLES SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION OR A GFCI
CIRCUIT BREAKER SHALL USED TO FEED THE CIRCUIT NOTED.
9
FUTURE IT EQUIPMENT
INSTALL DUPLEX AT MILLWORK WALL AT 18" AFF
ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HVAC CONTRACTORS FOR
ANY ADDITIONAL EQUIPMENT NEEDING POWER.
F.
ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN APPROPRIATE
RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY INDICATED. GFCI BREAKERS (NOT
RECEPTACLES) SHALL BE UTILIZED FOR ALL
G.
125V, 15A AND 20A CIRCUITS TO KITCHEN EQUIPMENT AND FLOOR BOXES. PROVIDE DEDICATED
NEUTRAL WIRE FOR ALL OF THESE CIRCUITS.
H.
3'-3"
2'-0"
E408
E427
OUTLET ABOVE
IN CABINET
1'-4"
RP-8
4
FROM CEILING.
N.
WIRE FROM J.BOX TO EQUIPMENT. INSTALL REMOTE CONTROLS SUPPLIED WITH
EQUIPMENT.
Q.
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND
SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH
GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT
ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND
DESIGN INTENT.
13
INTERIOR ILLUMINATED SIGNAGE:
PROVIDE CONTACTOR FOR CIRCUIT, CIRCUIT TO BE CONTROLLED WITH INTERIOR LIGHTING.
COORDINATE EXACT LOCATION OF OUTLET WITH MILLWORK. OUTLET TO BE LOCATED
BEHIND WALL CABINET DOOR.
R.
E.C. TO USE #8 WIRE AND 50 AMP CIRCUIT BREAKER.
14
FUTURE POS STATION
INSTALL DUPLEX AT BACKLINE WALL AT 44" AFF.
S.
50 AMP CORD, PLUG, PIN, AND SLEEVE RECEPTACLE WITH BACK BOX PROVIDED BY K.E.C.,
INSTALLED BY E.C.
T.
SURFACE MOUNT RECEPTACLE IN BOTTOM OF CABINET
U.
FOUR WIRE CONNECTION. UNIT PROVIDED WITH CORD AND PLUG, INSTALLED BY E.C.
V.
WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED BY K.E.C., INSTALLED BY E.C.
W.
STUB OUT MILLWORK WALL AND INSTALL OUTLET IN RECESS ON LEFT SIDE OF ICE CREAM
UNIT.
X.
WIRE DEFROST TIMER TO BLOWER COIL. PROVIDED BY K.E.C. INSTALLED BY E.C.
03
M109
E409
E7.0
6
E401
12'-4"
1
CEILING MOUNTED
45 KVA TRANSFORMERS
4
E304
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
P102
7'-0"
8'-0"
12'-2"
16'-4"
19'-0"
E103
11
11
P102
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
DATE
04-26-2016
05-23-2016
RP-4
RP-4
7
RP-13
+42" AFF
S
W.H.
J
P800
5
3
RP-21
+90" AFF
13
S216A
+36" AFF
LP-39
10
S
J
+42" AFF
RP-26
8
RP-8
+42" AFF
RP-13
+42" AFF
RP-26
+42" AFF
RP-26
8
RP-8
S
0334
St. Louis - Montreal
2
P716
8
RP-8
R
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
21'-10"
25'-8"
RP-26
+42" AFF
E
955
ILLINOIS DESIGN FIRM # 184.006688
ISSUE
DD SET
95% SET
J
P715
E107
H
ISSUE DATE
J
E406
C
Wells
2
2
E105
E302
8
RP-8
M.
12
12
9
FROM FLOOR.
OVEN OUTLET
GC TO PROVIDE LEVITON 8450 RECEPTACLE AT OVEN OUTLET (1 PER OVEN). CORD & PLUG TO
BE SUPPLIED BY VENDOR.
4'-10"
2
L.
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR
INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE
DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE
FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
E106
E106
CONNECTION INSIDE WALK-IN, FROM CEILING.
INSTALL EXTRA LIGHT SHIPPED LOOSE WITH EQUIPMENT. WIRE TO SWITCH ON WALK-IN,
RUN CONDUIT ABOVE WALK-IN. CAULK ALL PENETRATIONS AROUND CONDUIT INSIDE AND
OUTSIDE OF WALK-IN.
RP-10
E107
K.
P.
E404
E302A
WIRE FROM SWITCH IN WALK-IN PANEL TO LIGHTS IN GLASS DOOR.
11
6"
8
J.
PROVIDE AND INSTALL WALL SWITCH TO OPERATE REMOTE COMPRESSOR.
2'-7" 8 3/4"
1'-9 1/2"
WIRE FROM CONTROL PANEL TO FAN(S) ON EXTERIOR ROOF. PROVIDE AND INSTALL
DISCONNECT & SWITCH. LOCATE SWITCH PER PLAN.
O.
19'-6"
18'-0"
15'-11"
10'-7"
7'-0"
3'-2 1/2"
14
I.
AUTOMATIC PLUMBING FIXTURES
PROVIDE J-BOX/OUTLET FOR POWER AT TOILET FLUSH VALVE
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR
AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR
AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS.
R
4 0 4 S.
MUSICIAN'S AREA
QUAD & KILL SWITCH TIED TO MUSIC SYSTEM AT MANAGER'S DESK. KILL SWITCH TO TURN
ON/OFF SPEAKERS ONLY. MOUNT AT 3'-0" TO CENTER OF BOX
FIELD VERIFY ALL CONDITIONS:
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
A
10
E128
10" 1'-0"
3
WATER HEATER:
PROVIDE DISCONNECT SWITCH AND FEEDER ADJACENT TO WATER HEATER. SEE ELECTRICAL
CONNECTION SCHEDULE, SHEET E6.0.
4
E.
RP-14,16,18
RP-31,33,35
C,E
A.
PROJECT NUMBER: 16-059
NO.
ELECTRICAL SCHEDULE REMARKS:
KEYNOTES:
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
GENERAL NOTES:
ELECTRICAL SCHEDULE
SHEET TITLE
POWER
PLAN
SHEET NUMBER
E2.0
COORDINATE THE EXACT LOCATION AND MOUNTING HEIGHTS FOR
ALL THE LIGHT FIXTURES WITH THE REFLECTED CEILING PLAN
WITHIN THE ARCHITECTURAL SET
B.
LIGHT FIXTURES ARE FURNISHED BY THE OWNER, INSTALLED BY
THE GENERAL CONTRACTOR, AND WIRED BY THE ELECTRICAL
CONTRACTOR, U.N.O. REFER TO LIGHTING SCHEDULE SHEET E5.0.
C.
D.
REFER TO ARCHITECTURAL CASEWORK DETAILS FOR EXACT
LOCATIONS OF LIGHT FIXTURES LOCATED IN CASEWORK.
E.
ALL OUTLETS/SWITCHES IN THE PREP ROOM, SERVICE LINE AND
TOILET ROOMS SHALL BE WHITE WITH WHITE COVERPLATES AND
BROWN WITH BROWN COVERPLATES ELSEWHERE. THIS IS TO
INCLUDE ALL SOUND SYSTEM AND PHONE/ FAX COVERS.
L500
SEE SHEET E5.0 FOR COMPLETE LIGHTING SCHEDULE
G.
ALL LIGHTING FIXTURES ON THIS SHEET SHALL BE CIRCUITED TO
PANEL "LP". UNLESS OTHERWISE NOTED.
4
CONTRACTOR TO FIELD VERIFY ALL EXTERIOR LANDING LIGHTS ARE ARE ON A BACK-UP
POWER SUPPLY PER IBC SECTION 1006.3.
ALL LIGHTING IN KITCHEN/PREP AND BEVERAGE AREAS SHALL
HAVE PROTECTIVE SHIELDING.
L207
L613
L615
L208
L615
L615
LP-9g
LP-9g
LP-9g
L102
L102
L102
2 LP-5f
LP-9e
LP-9e
L310
L310
LP-9g
L302
RP-34
LP-11
L615
9
9
LP-13c
LP-13c
L400
2
L400
L104
LP-11
LP-11
TIME CLOCK
LOCATE TIME CLOCK AND CONTACTORS NEAR ELECTRICAL PANELS.
9
PROVIDE CURRENT LIMITING DEVICE
REFER TO LIGHTING FIXTURE SCHEDULE (ON SHEET E5.0-L620)
10
EMERGENCY EGRESS LIGHTING
PROVIDE IF NOT EXISTING (2) LAMP BATTERY BACKUP EGRESS LIGHTING FIXTURE. CIRCUIT
AS INDICATED.
11
INTERIOR SIGN POWER
PROVIDE J-BOX, DISCONNECT, AND FINAL CONNECTIONS FOR THE SIGN. THE SIGN IS
SUPPLIED BY OTHERS. FIELD VERIFY THE EXACT LOCATION AND REQUIREMENTS. VERIFY
LOCATION W/ PSW PRIOR TO INSTALL. SIGNAGE PERMIT BY OTHERS. REFER TO POWER
PLAN FOR CIRCUITING.
R
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
6
S203
R
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
SM
L615
L502
2
2
L500
LP-3
L207
LP-11
L200
LP-13b
LP-11
LP-13a
L102
LP-13a
L100
L100
LP-13
2
L500
L100
S100
LP-19
L502
10 2
LP-13a
L615
L208
2 LP-5f
LP-13a
L208
L100
L615
S100
L305
2
L502
LP-15
LP-11
LP-13
LP-13
LP-13a
3
2
LP-13b
LP-13b
11 S216A
L500
L109
L109
F503
DATE
04-26-2016
05-23-2016
7
LP-17
3
L208
L208
L615
L208
L615
LP-13
9
L503
SHEET TITLE
LP-13
2
L500
LIGHTING
PLAN
SHEET NUMBER
SCALE: 1/4"=1'-0"
S
0334
ILLINOIS DESIGN FIRM # 184.006688
ISSUE
DD SET
95% SET
L210
S219
01 LIGHTING PLAN
E
955
ISSUE DATE
LP-11
L202
L202
5
1 LP-5
NL
L208
L104
SM
L208
S220
LP-13
LP-13
8
NL
L311
A
LP-3h
L614
2 10
MASTER LIGHTING SWITCHBANK (ON SHEET E7.0)
PROVIDE SWITCHES AS IDENTIFIED BELOW UNDER SET(S) OF COMMON FACEPLATES.
SM
L615
L503
7
L500
LP-3h
1
LP-17
2
NIGHT LIGHTING
LIGHTS IDENTIFIED WITH "NL" TO BE ON UNSWITCHED LEG OF CIRCUIT.
2
LP-9e
2 LP-5f
L100
6
8
L302
4
S218
L100
LP-13a
COOLER LIGHTS
STRIPLIGHTS FURNISHED BY COOLER VENDOR, INSTALLED AND AND WIRED BY
ELECTRICAL CONTRACTOR.
L302
L203
LP-13a
L502
L302
LP-3
9
S100
2
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
L102
L100
3
5
LP-3
L615
LP-13a
6
LP-25
L613
9
HOOD LIGHTING
PROVIDE FINAL CONNECTION TO (2) 1-100W INCANDESCENT HOOD LIGHTS. LIGHTS
FURNISHED BY HOOD MANUFACTURER. SEE MECH.
LP-3h
L500
L210
3 LP-9f
L100
EXTERIOR SIGN POWER
PROVIDE J-BOXES AND (1) DEDICATED 120V, 20A DISCONNECT SWITCH ABOVE ACCESSIBLE
CEILING WITH (2) #10 CONDUCTORS AND SEPARATE #10 GROUNDING CONDUCTOR AND
FINAL CONNECTIONS FOR THE SIGN. THE SIGN IS SUPPLIED BY OTHERS. FIELD VERIFY THE
EXACT LOCATION AND REQUIREMENTS. VERIFY LOCATION W/ PSW PRIOR TO INSTALL.
SIGNAGE PERMIT BY OTHERS.
2
L502
FAN
L207
LP-13a
EMERGENCY/EXIT LIGHTING
WIRE EMERGENCY/EXIT LIGHTING TO THE UNSWITCHED LEG OF LOCAL AREA CIRCUIT AS
INDICATED.
LP-3
2
L210
REFRIGERATION EQUIPMENT
CONTRACTOR TO PROVIDE MATERIALS AND FINAL CONNECTION PER MANUFACTURERS
SPECIFICATIONS. THE WALK-IN COOLER LIGHT FIXTURE, DISPLAY LIGHTS, DOOR HEATER,
PILOT LIGHT SWITCH, AND DISPLAY LIGHT SWITCH IS PROVIDED WITH THE BOX. PROVIDE
SEAL-OFFS FOR THE CONDUIT PENETRATIONS AND ALL WIRING AS REQUIRED.
4 0 4 S.
4
LP-9
L614
3
BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND
ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN
STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT
WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY
APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT.
SEE TYPICAL MOUNTING DETAIL. SHEET A5.2.
LP-25
2
2
CONTRACTOR NOTE
F.
I.
S202
1
THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING
FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL
COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER
OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS
COST.
ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE
INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL
SCOPE OF WORK.
H.
LP-9
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO
BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT
SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO
EXISTING CONDITIONS.
PROJECT NUMBER: 16-059
A.
KEYNOTES
FIELD VERIFY ALL CONDITIONS
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
GENERAL NOTES
E3.0
1.
ALL FIRE ALARM EQUIPMENT SHALL BE OF AN APPROVED TYPE AND BE USED FOR THE
PURPOSE IT WAS INTENDED.
2.
ALL FIRE ALARM EQUIPMENT SHALL BE INSTALLED PER SECTIONS OF THE LOCAL CODE,
ADAAG, NEC, AND NFPA 72 WHICH EVER IS APPLICABLE.
3.
HVAC 24VAC LINE
S/D RELAY
L/S RELAY
RTU & MUA (TYPICAL)
4.
DUCT SMOKE DETECTOR AND LIFE SAFETY RELAY RTU SHUT DOWN CIRCUIT, TYPICAL FOR
EACH UNIT.
5.
6.
7.
6
1
SENSOR/THERMOSTAT
CONTRACTOR TO PROVIDE BACKBOX, CONDUIT (IF REQ'D) AND WIRE TO CEILING AREA TO
SUPPORT NEW THERMOSTAT OR SENSOR BY MECHANICAL CONTRACTOR. CONFIRM
LOCATIONS WITH POTBELLY CONSTRUCTION MANAGER.
ALL WIRING AND CABLING SHALL BE APPROVED FOR FIRE ALARM SYSTEM USE AND BE
INSTALLED PER NFPA 70 (NEC).
2
WHERE CABLING IS NOT EXPOSED TO THE POSSIBILITY OF MECHANICAL DAMAGE (CEILING
HEIGHT, ABOVE BAR JOIST), IT MAY BE RUN EXPOSED AND PROPERLY SECURED TO THE
BUILDING STRUCTURE. ALL FIRE WALL PENETRATIONS WILL BE WITH EMT TUBING SLEEVES
SEALED ON EACH SIDE OF THE PENETRATION WITH HIGH TEMPERATURE SILICONE FIRE
SEAL COMPOUND.
SPEAKER LOCATION
SPEAKER LOCATIONS SHOWN FOR REFERENCE. LOCATE ABOVE WOOD TRIM. SEE
NOTES ON SHEET E1.0 FOR SCOPE OF WORK.
3
MANAGER'S DESK
SEE DETAIL 3/E7.0 FOR ALL OUTLET AND CIRCUITING REQUIREMENTS.
WALL MOUNTED VISUAL OR AUDIO/VISUAL DEVICES SHALL BE INSTALLED PER LOCAL CODE,
ADAAG, AND NFPA 72. THEY SHALL BE MOUNTED 80 INCHES ABOVE FINISHED FLOOR LEVEL
OR 12 INCHES BELOW CEILING HEIGHT, WHICHEVER IS LOWER OR AS ENVIRONMENTAL
CONDITIONS REQUIRE.
MANUAL FIRE ALARMS SHALL BE INSTALLED PER LOCAL CODE AND NFPA 72. THEY SHALL
BE MOUNTED 42 TO 48 INCHES ABOVE FINISHED FLOOR TO THE OPERATING HANDLE AND
BE WITHIN 5 FEET OF ALL EXIT DISCHARGE DOORS OR AS ENVIRONMENTAL CONDITIONS
REQUIRE.
CIRCUITING ON THE FLOOR PLAN IS DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE
"THRU WIRING" WHERE AND WHENEVER POSSIBLE. VERIFY EXACT EQUIPMENT LOCATION IN
FIELD. COORDINATE WITH ON-SITE PROJECT MANAGER.
5
1
13 12
14
17'-5"
3
L602
S
L602
9
10
5
6
7
POS
EXTEND (1) CAT5e CABLE PER POS, PLUS (1) FOR FUTURE TO JBOXES AS PER DETAIL
12/E7.0.
PHONE/FAX ABOVE COUNTER
EXTEND (2) CAT5e CABLES FROM MANAGERS DESK TO TELECOM BOX @ 42" AFF.
FUTURE POS
EXTEND (1) CAT5e CABLE PER POS FOR FUTURE POS TO JBOXES AS PER DETAIL 12/E7.0.
WIRELESS ACCESS POINT
EXTEND (2) CAT5e CABLES FROM WIRELESS ACCESS POINT JUNCTION BOX LOCATED AT
HEIGHT ABOVE HIGH TRIM TO MANAGER'S DESK. VERIFY EXACT LOCATION WITH
POTBELLY REP PRIOR TO INSTALLATION.
8
NOT USED
9
SMOKE DETECTOR
A SMOKE DETECTOR IS REQUIRED PER NFPA 72 1-5.6 TO PROTECT THE CONTROL UNIT.
10
FUTURE IT EQUIPMENT
PROVIDE SINGLE CAT5e CABLE RUN BETWEEN THE JBOX AT LOAD STATION AND MANAGER'S
DESK. LOCATE AT 48" AFF NEXT TO ASSOCIATED RECEPTACLE.
11
SECURITY ALARM KEYPAD
APPROXIMATE LOCATION OF SECURITY ALARM KEYPAD ABOVE MASTER LIGHT SWITCH BANK.
12
ROUTER ABOVE MANAGER DESK
ROUTER TO BE WALL MOUNTED ABOVE MANAGER DESK. SEE DETAIL 03/E7.0.
13
SECURITY ALARM PANEL
SECURITY ALARM PANEL TO BE MOUNTED ABOVE MANAGERS DESK ON PHONE BOARD.
COORDINATE EXACT LOCATION WITH GC. SEE DETAIL 03/E7.0.
14
PATCH PANEL
EXTEND (1) CAT5E CABLE FROM PHONE JACK AT MANAGERS DESK TO PATCH PANEL.
A
R
4 0 4 S.
C
Wells
H
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
2
S
1
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
mechanical
electrical
plumbing
fire protection
structural
ISSUE DATE
ISSUE
DD SET
95% SET
2
S
DATE
04-26-2016
05-23-2016
4
W.H.
11
L601
7
2
2
L601
1
S
1
S
SHEET TITLE
SYSTEMS
PLAN
SHEET NUMBER
01 SYSTEMS PLAN
SCALE: 1/4"=1'-0"
S
0334
ILLINOIS DESIGN FIRM # 184.006688
7'-4"
4
R
E7.0
L602
4
E
955
03
1
9
2
4
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
PROJECT NUMBER: 16-059
HVAC 24VAC LINE
KEYNOTES
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
FIRE ALARM GENERAL NOTES:
E4.0
TYPE
MANUFACTURER
DESCRIPTION
Count
MODEL
LIGHTING SCHEDULE
LAMP
FURN INSTALL
VOLTS WATTS
B.O. FIXTURE
COMMENTS
L100
DECORATIVE PENDANT - 14"
CON-TEC
SCHOOL HOUSE FIXTURE
11
CM5601150 W/ 8' ASSEMBLY
PHILIPS 11A19/END/2700/DIM 6/1
VD
GC
120
23
7'-9" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L102
ANTIQUE GLOBE FIXTURE
CUSTOM BY PSW
DECORATIVE CHAIN HUNG FIXTURE WITH VINTAGE COLORED TEXTURE GLASS SHADE
5
CUSTOM
PHILIPS EL/MDT2 13W
VD
GC
120
14
7'-9" AFF TO BOTTOM
SEE DETAIL 09/A5.2
L103
WALL SCONCE
JUSTICE
WALL SCONCE W/ SHADE
1
POR-8921-20-PLET-DBRZ
PHILIPS 11A19/END/2700/DIM 6/1
VD
GC
L104
WALL SCONCE - TOILET ROOM
REJUVENATION
SELMA WHITE PORCELEIN
2
A4631 / B2002 SHADE
PHILIPS EL/MDT 23W
VD
GC
L109
CYLINDER PENDANT
CON-TECH
6" CYLINDER PENDANT W/ 24" STEM KIT AND MONOPOINT
3
CF6-42P-C-B / CSK24-B / LA18-B
PHILIPS PL-T 42W/835/4P/ALTO
VD
GC
L200
CEILING MOUNTED FIXTURE
THOMAS LIGHTING
2-LIGHT CEILING MTD, PAINTED BRONZE, 13 1/4"
1
PL869263L
2 (13W) CFQ13/G24q/827 (4 PIN)
VD
GC
120
26
CEILING MOUNTED
L202
CEILING MOUNTED TOILET RM FIXTURE
REJUVENATION
FRANCIS BLACK PORCELEIN W/ BLACK STRIPED SHADE
2
A7685 / B1489 BLACK STRIPED SHADE
23W GU24 LAMP
VD
GC
120
23
N/A
L203
SURFACE MOUNT COOLER STRIP LIGHT
METALUX VAPORITE
1 X4 STRIP LIGHT (2) LAMP
1
VT-232-120-EB81
GE F28T8/SP35/UMX/ECO; ORDER CODE: 00256 GC TO PROVIDE LAMPS
VD/GC
GC
120
42" AFF (LOW TABLES) / 54" AFF (HIGH TABLES)
120
23
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
CENTER FIXTURE ABOVE MIRROR AT 7'-0" AFF
13'-0" AFF TO BOTTOM
SEE DETAIL 09/A5.2
FIXTURE BY VENDOR, LAMPS BY GC
A
R
4 0 4 S.
L207
LED TRACK HEAD (MENU)
CON-TEC
PAR30 ROUND BACK CYLINDER TRACK HEAD
8
CTL230-B
SOLAIS LR30LN/25/30K/18W/1000/BK
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L208
LED TRACK HEAD (WALL FLOOD)
CON-TEC
PAR30 ROUND BACK CYLINDER TRACK HEAD
19
CTL230-B
SOLAIS LR30LN/40/30K/18W/1000/BK
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L210
LINEAR TRACK FIXTURE 48"
CON-TEC
LINEAR SLIM STYLE WALLWASH
3
CTL14154/HO-B
PHILIPS F54T5/835/HO/ALTO
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 13'-6" AFF
SEE DETAIL 12/A5.2
L302
RECESSED 2 X 4
COOPER
METALUX, 2X4, 3 LAMP FLUORESCENT FIXTURE
5
METALUX 2GR8-332A-UNV-EB81-U, 2X4 RECESSED
(3) PHILIPS LED T8 LAMPS; PRODUCT NO: 45359-7; ORDERING CODE: 12T8/48-3500 IF 10/1
VD
GC
L305
RECESSED 2 X 2
COOPER
METALUX, 2X2, 2 LAMP FLUORESCENT FIXTURE
1
2GC8-317A-UNV-EB81-U
(3) F17T8/SP35/ ITEM #45743
VD
GC
L310
6" RECESSED DOWNLIGHT (LED)
CON-TEC
6" INCADESCENT HOUSING AND TRIM
2
RL38 + CTR1902-WHT
SOLAIS LR38/25/30K/1025BK
VD
GC
L311
6" RECESSED DOWNLIGHT W/ WALLWASH (LED)
CON-TEC
6" INCADESCENT HOUSING AND WALLWASH TRIM
1
RL38 + CTR3807-WHT
LR38/25/30K/1025BK
VD
GC
L400
CEILING FAN
REVOLUTION LIGHTING
MARISSA, WALNUT PECAN, NO LIGHT KIT, VENETIAN BRONZE
2
MA52VBT
N/A
VD
GC
120
5
L500
EMERGENCY LIGHT
TECHNICAL CONSUMER PRODUCTS
EMERGENCY LIGHT TCP 20760 Emergency
7
20760
EMERGENCY HALOGEN LIGHTS
VD
GC
120
6
L502
EMERGENCY EXIT SIGN W/ LIGHTS
TECHNICAL CONSUMER PRODUCTS
COMBO EMERGENCY EXIT SIGN W/ (2) HEADS
4
TCP 20723
VD
GC
L601
WALL MOUNTED SPEAKER
SOUNDTUBE
WALL MOUNT SPEAKER
2
SM400I
VD
VD
GC TO INSTALL BACKER BOX FOR SPEAKERS
L602
CEILING MOUNTED SPEAKER
LOWELL
8" DUAL CONE SPEAKER ASSEMBLY
3
R SERIES
VD
VD
GC TO INSTALL BACKER BOX FOR SPEAKERS
L610
72" EXTENSION ROD
REVOLUTION LIGHTING
72" IRON DOWN ROD - DR72VB
2
DR72VB
VD
GC
FOR USE WITH L400 CEILING FAN.
L611
LAMP CHANGER KIT
MR. LONGARM INC.
LAMP CHANGER KIT
1
B8601 3030
VD
GC
L613
3' X 5' EXHAUST HOOD
JD HIGGINS
SS HOOD W/ 18" ENCLOSURE PANEL
2
3624
VD
GC
L614
4'-0" BLACK TRACK
CON-TECH
4'-0" BLACK TRACK FOR LED TRACK HEADS
2
LT-4-B
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L615
6'-0" BLACK TRACK
CON-TECH
6'-0" BLACK TRACK FOR LED TRACK HEADS
12
LT-6-B
VD
GC
IF NOT CEILING MOUNTED, MOUNT BOTTOM OF TRACK AT 12'-6" AFF
SEE DETAIL 07/A5.2
L617
TRACK END FEED
CON-TECH
END FEED (ONE NEEDED FOR EACH TRACK)
9
LA-10-B
VD
GC
L618
TRACK CONNECTOR
CON-TECH
CONNECTOR TO FIT MULTIPLE TRACKS TOGETHER
4
LA-2-B
VD
GC
L619
TRACK CORNER CONNECTOR
CON-TECH
CONNECTOR TO FIT TRACKS AT A 90 ANGLE
1
LA-12-B
VD
GC
L620
CURRENT LIMITING DEVICE
CON-TECH
CURRENT LIMITING POWER FEED
5
LA-23-RN
VD
GC
C
Wells
H
I
S t .,
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
E
955
R
S
0334
ILLINOIS DESIGN FIRM # 184.006688
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
St. Louis - Montreal
9'-0" AFF TO BOTTOM
SEE DETAIL 14/A5.2
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
WILL NOT BE USED IN ALL LOCATIONS. VERIFY WITH ENGINEERING
DRAWINGS
mechanical
electrical
plumbing
fire protection
structural
PROJECT NUMBER: 16-059
ITEM #
ISSUE DATE
ISSUE
DD SET
95% SET
DATE
04-26-2016
05-23-2016
SHEET TITLE
LIGHTING
SCHEDULE
SHEET NUMBER
E5.0
NOTE:EC SHALL USE THIS TIME SWITCH OR APPROVED
EQUIVALENT TO COMPLY WITH 2009 IECC.
(CHNL 2)
LP-15
EXTERIOR SIGN
(CHNL 1)
ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
ALL CONDUCTORS FOR VOLTAGE DROP.
EXTERIOR
LP-34
TS
TENANT
INTERIOR
TIMED WALL SWITCH (2 HOUR MAX.) FOR
OVERRIDING TIME-SWITCH
30
TS
C1
C1
SERVICE AREA LTG.
g
SERVICE TRACK LTG.
LP-13
SET TO TURN ON AND OFF PER PSW DIRECTION ON 24 HRS/DAY
LOCK ON CIRCUIT.
CHANNELS 2: TIME ON 4:30 PM- MIDNIGHT
AND 5:00 AM - 8:00 AM
TIME OFF - ALL OTHER TIMES
C1: AS DIRECTED BY STORE MANAGER.
e
C1
DAYLIGHTING
a
DINING ROOM LTG.
b
HALLWAY LTG.
d
LP-5
C1
LP-3
A
LOAD
STATION
DRESS STATION
2'-0" MIN.
(COORD. WITH ELEC. PLAN)
DISC. SWITCH
BY LL
TIME CLOCK DETAIL
CORD & PLUG SUPPLIED BY
VENDOR.
NEW
PANEL "RP"
208Y/120V,
3Ø, 4W
S t .,
I
T
Suite
E
300
C
T
S
Chicago,
+
IL
P
L
A
60607
N
N
P:
312
Scale: N.T.S.
796 Merus Court
St. Louis, MO 63026
T 636.349.1600
F 636.349.1730
aedificacase.com
PROVIDE CONTROL WIRING
FOR FAN SHUT DOWN
(1) RETURN
DUCT MOUNTED
SMOKE DETECTOR
MAPLE CHASE #0550
GC TO PROVIDE EMT DATA CONDUIT IN SECOND BAY OF P.O.STYPE TO BE CAT 5e CABLE (8 TOTAL).
PROVIDE 15 FEET OF EXCESS cat 5e CABLE AT P.O.S & 20 FEET OF
EXCESS CAT CABLE AT MANAGER'S DESK
RISER DIAGRAM
10
Scale: N.T.S.
QTY PER
PLAN OR AS
REQ'D.
1/2"C, 4 #14
SPEAKER WIRES TERMINATED
IN CEILING ABOVE MANAGER'S
DESK (LEAVE ADEQUATE
WIRE SLACK).
PHONE BOARD:
LOCATED ABOVE THE
MANAGER'S DESK.
1/2"C, 4 #14
REMOTE ANNUNCIATOR / RESET SYSTEM
SENSOR, MAPLE CHASE #0537,
LOCATED PER PSW DIRECTION
PROVIDE TYPED LABEL
INDICATING "HVAC DUCT
SMOKE DETECTOR".
GC TO PROVIDE 3 4" FLEX CONDUIT (IN FLOOR OR
ADJACENT WALL-REFER TO DRAWINGS) TO 1900 BOX
FROM ELECTRICAL PANEL.
EXTRA CABLE:
PROVIDE AN ADDITIONAL
20' OF SPARE CABLING AT
TELEPHONE BLOCK.
2' x 2' x 3/4" PLYWOOD w/FLAME
RETARDANT PAINT
NOTE: PROVIDE DETECTOR, HOUSING, TYPE, REMOTE STATION, AND ALL ACCESSORIES.
DETECTOR SHALL BE INSTALLED UNDER DIVISION 15. CONNECT DETECTOR AS SHOWN.
WHEN PSW SPACE IS MONITORED BY CENTRAL BUILDING FIRE ALARM SYSTEM, GC TO
COORDINATE WITH LANDLORD'S ALARM CONTRACTOR TO CONNECT BUILDING ALARM
SYSTEM TO DUCT DETECTOR AUXILIARY CONTACTS.
TERMINAL
BLOCKS
GC TO PROVIDE (2) 1" DATA CONDUIT
mechanical
electrical
plumbing
fire protection
structural
PHONE
SYSTEM
MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL DUCT DETECTOR WITH MINIMUM TWO
SETS OF AUXILIARY CONTACTS
ISSUE DATE
ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL CONTROL WIRING FROM DUCT
DETECTOR TO AC UNIT
SECTION THRU POS COUNTER FROM CUSTOMER SIDE
Scale: N.T.S.
8
1 Cat5e
2 Cat5e
ISSUE
DD SET
95% SET
1 Cat5e
DUCT SMOKE DETECTOR
DATE
04-26-2016
05-23-2016
Scale: N.T.S.
24 PORT CISCO SWITCH
PATCH PANEL
WINDSTREAM ROUTER (LP-23)
8'-8"
SECURITY ALARM PANEL
(LP-21)
30" X 60" - 3/4" FRT PLYWOOD
PHONE BOARD ABOVE SHELVING,
PAINT TO MATCH WALL.
MUSIC PLAYER
& AMP
5"
SERVER
QUAD OUTLET MOUNTED ON
PHONE BOARD FOR PHONE
EQUIPMENT. (LP-36)
DEDICATED DUPLEX OUTLET FOR
SOUND SYSTEM (LP-41)
PROVDE 4" SQUARE JUNCTION BOX
AND 1-1/4" CONDUIT TO ACCESSIBLE
CEILING FOR SOUND SYSTEM
ISOLATED GROUND, DEDICATED
QUAD OUTLET FOR POWER SUPPLY
(LP-40)
SWITCH
6"
9"
POWER
SUPPLY
3'-10"
3'-4"
OUTLETS FOR GENERAL USE
(LP-42)
e
f
g
h
i
S
S
S
S
S
S
S
S
S
DATA LINES TO
MANAGER'S DESK
EQUIPMENT
MANAGER'S
DESK
(1) RJ45
(2) RJ45
(1) RJ45
(1) RJ11
(1) RJ45
S
INDICATES SWITCH
SHEET TITLE
NOTES:
1.
ALL WORK AND MATERIALS FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHERWISE.
2.
PROVIDE PLENUM RATED CABLING FOR ABOVE THE CEILING WHERE "PLENUM RATED AIR SPACE" SYSTEMS ARE REQUIRED.
3.
PROVIDE CONDUIT FOR DATA LINES IF REQUIRED BY CODE.
4.
DATA TERMINATION BY POTBELLY VENDOR.
ELECTRICAL
DETAILS
6'-2"
4'-0"
1'-6"
SAFE
SHRED
4'-11"
d
a - STOREFRONT LTG/DAYLIGHTING
b - DINING LTG
c - CEILING FANS MOTORS
d - HALLWAY LTG (IF REQUIRED)
e - SERVICE AREA-PERIMETER LTG QUEING
f - SERVICE AREA-PERIMETER TRACK LTG
g - SERVICE AREA-PERIMETER CENTER LTG
h - PREP AREA LTG
i - DINING, MUSICIAN (IF REQUIRED)
4'-9"
4'-8"
c
P.O.S.
TERMINAL
CONTROL ZONE SCHEDULE
3'-9"
FILE
CABINET
b
P.O.S.
TERMINAL
REMOTE
PHONE/FAX
NETBOOK
(3) JBOXES FLUSH FOR VOLUME
CONTROLS. PROVIDE STAINLESS
STEEL BLANK PLATES FOR
UNUSED OPENINGS.
a
P.O.S.
TERMINAL
JBOX FOR FUTURE IT NEEDS
PRINTER
WALL MOUNTED PHONE
SHEET NUMBER
NOTE: ALL ZONES MAY NOT BE USED. REFER TO E3.0 FOR ADDITIONAL
INFORMATION.
3
S
0334
St. Louis - Montreal
EC IS RESPONSIBLE FOR FIELD VERIFICATION OF SITE CONDITIONS AND COORDINATING ALL ELECTRICAL
SERVICE REQUIREMENTS WITH LOCAL UTILITY. EC SHALL REPORT ANY DIFFERENCES OR DISCREPANCIES
TO ENGINEER PRIOR TO BID. NO EXTRAS OR CHANGE ORDERS SHALL BE GIVEN FOR THE EC'S FAILURE TO
VISIT SITE PRIOR TO BIDING.
Scale: N.T.S.
SAMPLING TUBE
SIZED FOR DUCT
GC TO PROVIDE A 1-1/2" DEEP J-BOX WITH SINGLE QUAD
RECEPTACLE. CIRCUIT TO BE ISOLATED DEDICATED. REFER TO
PANEL SCHEDULE.
POS END PANEL
3'-2"
R
SINGLE OVEN OUTLET / BACK BOX DETAIL
7
HVAC DUCTWORK
NOTE: ALL CONDUITS, CABLING, J-BOXES &
DEVICES SHALL BE MOUNTED IN MILLWORK STUD
WALL SO NOT TO INTERFERE WITH THE
OPERATION OF THE REMOVABLE FRONT PANEL
OF THE POS COUNTER.
THERMOSTAT LOCATIONS.
PROVIDE SINGLE GANG JUNCTION
BOX W/ PULL STRING TO
ACCESSIBLE CEILING. PROVIDE
SAME NUMBER OF BOXES AS
HVAC UNITS, TYP (2) STACK
THERMOSTATS.
E
955
GENERAL CONTRACTOR AND ELECTRICIAN TO REFER TO LEASING
AGREEMENT PRIOR TO BIDDING
120 V
2
H
NEW
PANEL "LP"
208Y/120V,
3Ø, 4W
EC TO PROVIDE 2 SETS OF (4#3Ø
+1#3 GND IN 2"C) IN LL PROVIDED
CONDUIT AS REQUIRED
1'-6"
SPARE
* = ALL EMERGENCY/EXIT/NIGHT LIGHTING SHALL BE
CIRCUITED AHEAD OF ALL LIGHTING CONTROLS.
GC TO MOUNT (1) EMPTY J-BOX IN EACH OF (3)
CENTER BAY SECTIONS ON 2X4'S. J-BOXES TO BE
TYPE 1900 (1-1/2" DEEP) WITH 1/2" MUDRING
READY TO ACCEPT DATA CONNECTION PLATE.
INSTALL BX CONNECTOR TO ACCEPT DATA WIRE.
NEW
PANEL "PP"
480Y/277V,
3Ø, 4W
PREP ROOM LTG.
C1
1
C
Wells
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND
PROPRIETARY PROPERTY OF DXU, LLC. AND SHALL NOT BE COPIED
OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE
CONTRACT DOCUMENTS WERE PREPARED FOR USE ON THIS
SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT
SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE
OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER
PROJECT REQUIRES THE SERVICES OF DXU, LLC. REPRODUCTION OF
THE CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS
NOT AUTHORIZED.
C/T
BY LL
GC TO PROVIDE LEVITON 8450
RECEPTACLE - (1) PER OVEN.
PLUG TO BE PERPENDICULAR TO
FLOOR
DINING ROOM TRACK
C1
NEW 4-#2/0 THWN & 1-#6,
2"C
NEW 3#4 THWN & 1#6
1 1/4" C
h
--
R
4 0 4 S.
M
ILLINOIS DESIGN FIRM # 184.006688
f
C1
NEW #6 CU.
NEW #6 CU.
PROJECT NUMBER: 16-059
LP-9
SPARE
EC TO INSTALL METER
PER UTILITY
COMPANY
REQUIREMENTS
WIRE TROUGH
111 N. CANAL STREET, SUITE 850
CHICAGO, IL. 60606
P: 312.951.0600 F: 312.951.0300
WWW.POTBELLY.COM
"T-LP" 45KVA, TRAPEZE OR WALL
MOUNTED XFMR. 480V, 3Ø, DELTA
PRI.-208/120V, 3Ø, 4W WYE SEC.
BAL - ELKRIDGE LANDING:
1622 W. NURSERY ROAD, SUITE C
LINTHICUM HEIGHTS, MD 21090
--
LIGHTING/SIGNAGE CONTROLLER: TORK MODEL #DZS200BP
120V, 2 CHANNEL ELECTRONIC TIMECLOCK WITH MANUAL
OVERRIDE. INCLUDE ALL CONTROL WIRING AS REQ'D PER
MANUFACTURER. PROVIDE CONTACTORS AS REQ'D TO
PROVIDE SUFFICIENT POLES FOR ALL LIGHTING AND SIGNAGE.
TIMECLOCK AND CONTACTORS TO BE PROVIDED WTIH NEMA-1
ENCLOSURES.
"T-RP" 45KVA, TRAPEZE OR WALL
MOUNTED XFMR. 480V, 3Ø, DELTA
PRI.-208/120V, 3Ø, 4W WYE SEC.
MANAGER'S DESK - POWER ELEVATION
Scale: N.T.S.
9
MASTER LIGHTING SWITCHBANK
Scale: N.T.S.
12
P.O.S. DATA/PHONE/VIDEO ONE-LINE DIAGRAM
Scale: N.T.S.
E7.0