Wallbox Translator
Transcription
Wallbox Translator
Wallbox Translator Connect any vintage wallbox to your jukebox ... TRANSLATED WALLBOX MODEL TYPES • • • • • • • • • • • • • • • • • • • • • • AMI W-40 AMI W-80 AMI W-120 AMI WQ-200 Rock-Ola 500 Rock-Ola 503 Rock-Ola 1555 Rock-Ola 1558 Rowe WRA Rowe WRB Rowe WRC Seeburg 3W1 Seeburg 3W100 Seeburg 3WA Seeburg SC1-4 Seeburg SCH1-4 Wurlitzer 3020 Wurlitzer 5207 Wurlitzer 5210 Wurlitzer 5220 Wurlitzer 5225 Wurlitzer 5250 NOTE: Your jukebox must have a stepper or wallbox receiver in order to play wallbox selections. This wallbox translator allows you to connect any model wallbox to your specific jukebox. It does this by receiving the input wallbox signal, aligns the title strip sequence, then outputs the pulse signals matched to you jukebox. Wallbox selections are stored in memory and each selection is issued with a delay in between to allow the jukebox stepper to reset. No wallbox selected songs are ever lost. Features • • • • • • • • Title strip selections are maintained in sequential order across wallbox types Output is blocked if the input selection exceeds the output limit Expandable to mixed or same wallbox type (requires a server unit) Wallbox can be located up to 2,000 feet from translator LED indicator shows translator activity Input/output signals are fully isolated Can be used as a wallbox or stepper tester A 50Hz line frequency version is available Data Sync Engineering P.O. Box 539, 2 Footbridge Lane Blairstown, New Jersey 07825 TEL: (908) 362-6299 FAX: (908) 362-5889 www.datasynceng.com Copyright © 2009 Data Sync Engineering. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. NOT SUPPLIED But required to power wallbox Black wire is not used. Apply tape or wire nut. 22AWG distance of up to 2,000 feet (609.6 meters) In-line fuse holder with 1A fuse DATA LINK CONNECTOR Selects the output wallbox type COMMON SIGNAL TO JUKEBOX OR PLAYER SYSTEM ©2009 All Rights Reserved Data Sync Engineering Translates any 3-wire electro-mechanical wallbox WALLBOX TRANSLATOR / REPEATER SWITCHES 5 6 7 8 Selects the input wallbox type 50Hz or 50Hz/60Hz mixed input/output is available. Included with kit (2.1mm Center pin positive) DC POWER SUPPLY Connects to one or more "Server Units" to expand wallbox capacity. Up to 50 mixed or same WB types. SWITCHES 1 2 3 4 POWER TRANSFORMER 25-30 VAC, 2 Amps Radio Shack 273-1512 or equivalent WALLBOX POWER COM 25VAC SIG (YELLOW) WALLBOX SELECTOR (YELLOW) CONFIGURATION SWITCHES O N 1 2 3 4 5 6 7 8 WALLBOX ADAPTER TEST Set wallbox model to "Test Mode", touch a 9 -volt battery to the adapters' wallbox wires. Selection # 005 s hould play. O F F 5 6 7 8 OFF OFF OFF OFF Rock-Ola 500, 1555, 1558 (and most other models) OFF OFF OFF ON Seeburg Consolette SC1/2/3/4, SCH1/2/3/4 OFF OFF ON OFF Wurlitzer 5210, 5220, 5250 OFF OFF ON ON Seeburg Wall-O-Matic 3W1, 3W100 OFF ON OFF OFF Seeburg Wall-O-Matic 3WA OFF ON OFF ON Rowe WRA, WRB, WRC OFF ON ON OFF AMI W-40, W-80, W-120, WQ200 OFF ON ON ON Wurlitzer 5207 ON OFF OFF OFF Wurlitzer 5225 ON OFF OFF ON Wurlitzer 3020 ON OFF ON OFF -NA- ON OFF ON ON -NA- ON ON OFF OFF -NA- ON ON OFF ON -NA- ON ON ON OFF -NA- ON ON ON ON -NA- 1 2 3 4 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OUTPUT WALLBOX MODEL INPUT WALLBOX MODEL Max Sel Seq Rock-Ola 500, 1555, 1558 (and most other models) 200 Page ON Seeburg Consolette SC1/2/3/4, SCH1/2/3/4 160 Letter ON OFF Wurlitzer 5210, 5220, 5250 200 Number OFF ON ON Seeburg Wall-O-Matic 3W1, 3W100 100 Number OFF ON OFF OFF Seeburg Wall-O-Matic 3WA 200 Letter OFF ON OFF ON Rowe WRA, WRB, WRC 200 Letter OFF ON ON OFF AMI W-40, W-80, W-120, WQ200 200 Page OFF ON ON ON Wurlitzer 5207 104 Button ON OFF OFF OFF Wurlitzer 5225 100 Number ON OFF OFF ON Wurlitzer 3020 24 Button ON OFF ON OFF Rowe WRA, WRB, WRC (Translated to "200/Number" format) 200 Letter ON OFF ON ON Alternate Rowe WRA, WRB, WRC 200 Letter ON ON OFF OFF Alternate Seeburg Wall-O-Matic 3W1, 3W100 100 Number ON ON OFF ON Alternate Wurlitzer 5225 100 Number ON ON ON OFF "Test Mode" Plays song number "005" on any wallbox voltage signal ON ON ON ON Factory use only WALLBOX TRANSLATION CHART SEQUENCED NUMBERS SEQUENCED LETTERS SELECTION NUMBER RECORD NUMBER NBR LTR SEL REC NBR LTR SEL REC NBR LTR SEL REC NBR LTR SEL REC A1 A2 A3 A4 A5 A6 A7 A8 A9 A0 A1 B1 C1 D1 E1 F1 G1 H1 J1 K1 001 002 003 004 005 006 007 008 009 010 100 200 101 201 102 202 103 203 104 204 F1 F2 F3 F4 F5 F6 F7 F8 F9 F0 L3 M3 N3 P3 Q3 R3 S3 T3 U3 V3 051 052 053 054 055 056 057 058 059 060 125 225 126 226 127 227 128 228 129 229 L1 L2 L3 L4 L5 L6 L7 L8 L9 L0 A6 B6 C6 D6 E6 F6 G6 H6 J6 K6 101 102 103 104 105 106 107 108 109 110 150 250 151 251 152 252 153 253 154 254 R1 R2 R3 R4 R5 R6 R7 R8 R9 R0 L8 M8 N8 P8 Q8 R8 S8 T8 U8 V8 151 152 153 154 155 156 157 158 159 160 175 275 176 276 177 277 178 278 179 279 B1 B2 B3 B4 B5 B6 B7 B8 B9 B0 L1 M1 N1 P1 Q1 R1 S1 T1 U1 V1 011 012 013 014 015 016 017 018 019 020 105 205 106 206 107 207 108 208 109 209 G1 G2 G3 G4 G5 G6 G7 G8 G9 G0 A4 B4 C4 D4 E4 F4 G4 H4 J4 K4 061 062 063 064 065 066 067 068 069 070 130 230 131 231 132 232 133 233 134 234 M1 M2 M3 M4 M5 M6 M7 M8 M9 M0 L6 M6 N6 P6 Q6 R6 S6 T6 U6 V6 111 112 113 114 115 116 117 118 119 120 155 255 156 256 157 257 158 258 159 259 S1 S2 S3 S4 S5 S6 S7 S8 S9 S0 A9 B9 C9 D9 E9 F9 G9 H9 J9 K9 161 162 163 164 165 166 167 168 169 170 180 280 181 281 182 282 183 283 184 284 C1 C2 C3 C4 C5 C6 C7 C8 C9 C0 A2 B2 C2 D2 E2 F2 G2 H2 J2 K2 021 022 023 024 025 026 027 028 029 030 110 210 111 211 112 212 113 213 114 214 H1 H2 H3 H4 H5 H6 H7 H8 H9 H0 L4 M4 N4 P4 Q4 R4 S4 T4 U4 V4 071 072 073 074 075 076 077 078 079 080 135 235 136 236 137 237 138 238 139 239 N1 N2 N3 N4 N5 N6 N7 N8 N9 N0 A7 B7 C7 D7 E7 F7 G7 H7 J7 K7 121 122 123 124 125 126 127 128 129 130 160 260 161 261 162 262 163 263 164 264 T1 T2 T3 T4 T5 T6 T7 T8 T9 T0 L9 M9 N9 P9 Q9 R9 S9 T9 U9 V9 171 172 173 174 175 176 177 178 179 180 185 285 186 286 187 287 188 288 189 289 D1 D2 D3 D4 D5 D6 D7 D8 D9 D0 L2 M2 N2 P2 Q2 R2 S2 T2 U2 V2 031 032 033 034 035 036 037 038 039 040 115 215 116 216 117 217 118 218 119 219 J1 J2 J3 J4 J5 J6 J7 J8 J9 J0 A5 B5 C5 D5 E5 F5 G5 H5 J5 K5 081 082 083 084 085 086 087 088 089 090 140 240 141 241 142 242 143 243 144 244 P1 P2 P3 P4 P5 P6 P7 P8 P9 P0 L7 M7 N7 P7 Q7 R7 S7 T7 U7 V7 131 132 133 134 135 136 137 138 139 140 165 265 166 266 167 267 168 268 169 269 U1 U2 U3 U4 U5 U6 U7 U8 U9 U0 A0 B0 C0 D0 E0 F0 G0 H0 J0 K0 181 182 183 184 185 186 187 188 189 190 190 290 191 291 192 292 193 293 194 294 E1 E2 E3 E4 E5 E6 E7 E8 E9 E0 A3 B3 C3 D3 E3 F3 G3 H3 J3 K3 041 042 043 044 045 046 047 048 049 050 120 220 121 221 122 222 123 223 124 224 K1 K2 K3 K4 K5 K6 K7 K8 K9 K0 L5 M5 N5 P5 Q5 R5 S5 T5 U5 V5 091 092 093 094 095 096 097 098 099 100 145 245 146 246 147 247 148 248 149 249 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q0 A8 B8 C8 D8 E8 F8 G8 H8 J8 K8 141 142 143 144 145 146 147 148 149 150 170 270 171 271 172 272 173 273 174 274 V1 V2 V3 V4 V5 V6 V7 V8 V9 V0 L0 M0 N0 P0 Q0 R0 S0 T0 U0 V0 191 192 193 194 195 196 197 198 199 200 195 295 196 296 197 297 198 298 199 299 Wallbox Wiring Diagrams CAUTION: Do not attempt to hook up a wallbox power supply if you are not familiar with electrical wiring, consult with a qualified person or an electrician. Do not leave any wires exposed, always use wire-nuts or electrical tape on all connections. Improper wiring can result in a fire or shock hazard. Seeburg Wall-o-matic 3W1 / 3W100 100 select SIGNAL 25VAC COMMON Seeburg Wall-o-matic 3WA 200 select COMMON 25VAC SIGNAL Seeburg Consolette SC1-4 / SCH1-4 160 select BLK WHT BLU COMMON 25VAC SIGNAL To enable coin operation, the BRN / RED / ORG terminals must be shorted together and connected to the 25VAC terminal (WHT) using a 40-50 Ohm, 10 Watt power resistor (solenoid current = 400mA). Wurlitzer 5220 200 select Wurlitzer 5225 100 select 25VAC COMMON 3 G SIGNAL 1 Wurlitzer 5207 104 select SIGNAL COMMON 25VAC AMI W-40 / W-80 / W-120 40 / 80 / 120 select 25VAC SIGNAL COMMON Rowe WRA / WRB / WRC 200 select A wire jumper must be inserted from the 25VAC main power terminal (#2) to the 25VAC* keypad motor terminal (#4). 1 COMMON 2 25VAC 3 SIGNAL 4 25VAC* Wurlitzer 5210 200 select 25VAC COMMON SIGNAL SIGNAL COMMON 25VAC Wurlitzer 5250 200 select COMMON SIGNAL 25VAC COMMON Rock-Ola 1555 200 select SIGNAL 25VAC Rock-Ola 1558 160 select Rock-Ola 500 160 select 25VAC COMMON SIGNAL Wurlitzer 3020 24 select The Original 1015 Bubbler Wallbox SIGNAL 25VAC 120VAC This wallbox has its own “built-in” transformer and requires a 120VAC power cord. High voltage is used so be very careful when wiring up this wallbox. The wallbox adapter only requires the two wire connection to terminal #1 and terminal #3. AMI WQ-200 200 select A wire jumper must be inserted from the 25VAC main power terminal to the 25VAC* lock-out. TECH NOTE Electrical pulses transmitted by the wallbox are generated by a contact arm rotating on a selector disc containing contact points. When these contacts become gummed up and corroded, the wallbox may not make the proper selection. Occasionally, these contacts require cleaning. They can be cleaned with a cloth saturated with isopropyl alcohol. Do not use emery cloth or sandpaper as this may remove the plating. On really worn wallboxes, where basic cleaning doesn’t seem to cure the problem, you may have successful results by using a low abrasive polish, such as “Scratch Out” or “Brasso”. This will make the contact surfaces shiny and smooth. COMMON 25VAC SIGNAL 25VAC*
Similar documents
3-Wire Wallbox Adapter
Wallbox Wiring Diagrams CAUTION: Do not attempt to hook up a wallbox power supply if you are not familiar with
More information