Westfield Oakridge - Westfield Tenant Coordination
Transcription
Westfield Oakridge - Westfield Tenant Coordination
RETAIL Tenant criteria manual Westfield Oakridge 925 blossom hill rd • San jose • cA 95123 Date: Aug 2010 Mission Statement It is our mission at Westfield to distinguish ourselves through superior performance in retail development and continuous improvement of our portfolio to meet the changing needs of our customers and the retailers we serve. Our commitment to you is to furnish a well-designed, well-maintained and wellmarketed retail environment capable of maximizing traffic and sales. Westfield will become your partner in upgrading the quality of retailing through better Tenants. We are very pleased to become partners with retailers striving for these same goals and are ready to meet your needs, facilitate communication and share our expertise with you to complete your store on time. Welcome to Westfield Oakridge. We wish you great success with the completion of your store and look forward to a mutually profitable relationship. Westfield Oakridge 925 Blossom Hill Road San Jose CA 95123-1294 Telephone: (408) 578 2912 Email: [email protected] Table of Contents 0.0 M I S S I O N S TAT E M E N T 1.0 M A L L P L A N Vicinity Map Site Plan 2.0 D E S I G N G U I D E L I N E S Design Intent Storefront Design Store Interiors Store Signage/Blade Sign & Graphics 3.0 S TO R E F R O N T / B L A D E S I G N ZO N E Storefront Zoning Plan - Level 1 Blade Sign Zoning Plan - Level 1 4.0 T E C H N I C A L C R I T E R I A ARCHITECTURAL Zone 1 Storefront Detail Zone 2 Storefront Detail Zone 3 Storefront Detail 5.0 E N G I N E E R I N G Mechanical Design Electrical Design Plumbing Design Smoke / Fire Alarm Design Fire Suppression Design 6.0 T E N A N T S U B M I S S I O N P R O C E S S Phase I : Preliminary Drawings Phase II : Final Drawings Phase III : Signage Drawing Phase IV : Completion Requirements 7.0 S TO R E CO N S T R U C T I O N 8.0 G E N E R A L I N F O R M AT I O N Landlord’s Coordinating Staff Government Agencies Utility Company Directory Applicable Codes Designated Engineers & Subcontractors Glossary 9.0 A D D E N D A 1.0 MALL PLAN 4 | Westfield Oakridge 1.0 MALL PL AN Vicinity Map Westfield Oakridge 925 Blossom Hill Rd. San Jose, CA 95123 Retail Criteria Manual | 5 1.0 MALL PL AN Site Plan 6 | Westfield Oakridge 2.0 DESIGN GUIDELINES Retail Criteria Manual | 7 2.0 DESIGN GUIDELINE Design Intent DESIGN INTENT The following Design Criteria establishes the standards of quality and design for each Retail Tenant to encourage compatibility with adjacent Tenants as well as the overall design philosophy of the project. The Design Criteria is divided into two main sections — Design Guidelines and Technical Criteria. The Design Guidelines cover overall general requirements for all Tenants, regardless of their type or location. The Technical Criteria, Architectural & MEP, each address requirements specific to the different zones and shop types. The Design Guidelines are a basic “set of rules” that the Tenant is required to work with and expand upon. It is written to encourage freedom of expression for all Tenants. Through the Criteria, Tenants are encouraged to create innovative and creative storefronts and shop interiors through the use of graphics, fixturing, detailing, dramatic lighting and color. By following the Criteria, each Tenant can create an inviting and effective retail establishment compatible with the overall design concept and image of Westfield malls. 8 | Westfield Oakridge 2.0 DESIGN GUIDELINE Design Intent The design of each Retail Tenant at the Westfield mall includes three major components, each subject to separate guideline requirements. These components are: • Storefront • Store Interiors • Store Signage and Graphics The Criteria is written to encourage freedom of expression and creativity, while establishing a common point of departure for all Tenants. Each Tenant, its Architect or Designer, Contractor and Representative should familiarize themselves with the intent, scope, requirements and details of the Criteria. National and Regional Tenants, who have recognizable store designs, are also expected to review these Criteria and modify their design prototypes to ensure compatibility with and compliance to the following Criteria. Any modifications of or deviations from these Criteria must be reviewed with the Landlord and will be subject to The design of each Retail Tenant at a Westfield mall includes three major components, each subject approval by the Landlord. to separate guideline requirements. These are: Storefront, Store Interiors, and Store Signage and Graphics. These Criteria are a basic "set of rules" the Tenant is required to work with and expand upon. Retail Criteria Manual | 9 2.0 DESIGN GUIDELINE Storefront Design STOREFRONT DESIGN The environment of the Westfield mall is largely dependent on the design of Tenant storefronts. The Tenant and the Tenant design team should familiarize themselves with the overall image and design of the Westfield mall to encourage compatibility of their storefront with the project. Storefronts within the Westfield mall are intended to display merchandise in an exciting and innovative promotional manner. Proper attention should be paid to the design and detailing of the storefront and display areas within their Design Control Zone including proportion, scale, color and detailing so as to be compatible with the character of the surrounding environment and district in which they are located. Additionally, careful attention to detail should extend to all public portions of the store. Each store will be reviewed individually for compatibility with the surrounding architectural context and overall project image. Vertical mullions are not permitted. STOREFRONT 10 | Westfield Oakridge 2.0 DESIGN GUIDELINE Storefront Design We have developed a Storefront Criteria with specific All storefronts shall be designed, fabricated and design elements which establish a “design language” installed by the Tenant at the Tenant’s expense and that should be incorporated into each Tenant’s subject to Landlord approval. Except where noted otherwise in the Technical Criteria, Tenant storefronts storefront design. These elements are: shall be 90% minimum transparent with direct views • Provide an individual look while implementing the overall design intent of the project into display areas and/or store interiors. Excessive use of continuous full height length opaque material will • Use high quality, durable materials such as: glass, not be permitted. glossy metal panels and polished stone • Provide maximum transparency from the public area into the Lease space. • Utilize 100% transparent material wherever possible on storefront • Emphasize Entries, Display Windows and Merchandise • Incorporate high quality graphics in displays and sales areas Incorporate three dimensional design elements at storefront (i.e., Entries, Eyebrows, Display Windows) to accent glazing plane. Retail Criteria Manual | 11 2.0 DESIGN GUIDELINE Storefront Design S T O R E F R O N T M AT E R I A L S Tenants must employ high quality materials in U S E O F T H E F O L L O W I N G M AT E R I A L S • Clear mirror construction of their storefront. ARE PROHIBITED: • Plywood or MDF panels • Plastic laminates USE OF THE FOLLOWING FINISH M AT E R I A L S I S E N C O U R A G E D : • Marble, granite, terrazzo, limestone and other • Vinyl wall covering or wallpaper the Landlord, is of poor quality, inappropriate • Painted drywall finish, or is incompatible with adjacent Tenant or • Textured paint, stucco, shingles, cork, or carpet common area finish materials • Vinyl tile or sheet vinyl natural stones • Any other material which, in the sole opinion of • Metals, mechanically finished (brushed and polished) or factory painted • Finished woods - paneling, trim, flooring, moldings and millwork • Glossy materials such as glass, transparent and back painted • High quality synthetic textured finishes • Other quality, durable materials STOREFRONT 12 | Westfield Oakridge 2.0 DESIGN GUIDELINE Storefront Design D I S P L AY W I N D O W S With increased transparency of the Storefront, Opaque portions of the storefront facing the additional attention must be placed on Display public area shall not exceed 10% of the storefront area, Window design and presentation. As the boundary i.e. 90% of storefront shall be either transparent, clear between Landlord common area and Tenant space glass, or openings designed to provide a view into the becomes more transparent, dynamic display areas display area or store. Excessive use of continuous full offer the Tenant an opportunity to visually bring their height length opaque material will not be permitted. store interior beyond the lease line and present the customer with vibrant and innovative merchandising that changes through the seasons. Tenants must use a minimum of 60% of the storefront width for display. Although display areas may at times be backed by partial or full height partitions, Tenants are required to maximize transparency from the public area into the Tenant’s sales area. Backing walls or fixtures in the display window that partially block views into the sales floor, from the common area, are permitted as long as sight lines into the space are maintained across the entire storefront width. APPEAL Retail Criteria Manual | 13 2.0 DESIGN GUIDELINE Storefront Design EXTENSION OF PROJEC T FLOOR M AT E R I A L S A N D S T O R E F R O N T B A S E Where parts of the storefront are recessed behind the lease line, the common area floor finish is to be extended from the lease line at the Tenant’s expense to the actual storefront and store closure to achieve full continuity of the common area floor finishes. Within the Tenant’s space, the level of the finished floor must match the level of the common/public area finished floor at storefront entry. T H E S T O R E F R O N T B A S E M AY B E A N Y ONE OF THE FOLLOWING: • The storefront glazing may continue to the finish floor but must terminate in a 1” aluminum glazing shoe installed on the concrete slab so that it is concealed by floor finish of the public space • A 4”–8” high granite, marble, or other natural stones base matching the Tenant’s storefront materials No threshold, reducer strips, or other wide transition • A 4”–8” high stainless steel, brass, anodized devices shall be permitted at the intersection of the aluminum, or enameled base integrated with the project flooring and the store interior flooring. Thin rest of the storefront design stainless steel (SS) transition strips are allowed. Vinyl or rubber bases will not be permitted. 14 | Westfield Oakridge 2.0 DESIGN GUIDELINE Storefront Design BULKHEADS AND STRUCTURE D E M I S I N G P I E R S A N D PA R T I T I O N S The bulkheads of the project are constructed of The surfaces adjacent to storefronts have been Demising piers or columns, with Landlord provided painted gypsum board. Any storefront work requiring designed to provide a framework for quality finishes, cannot be concealed by any projection of any structural support, including doors, must be braced to storefront design and to create order between part of the Tenant’s storefront. the structure and not to the bulkhead. Any attachment storefronts resulting in a well-designed retail to the structural system will require approval by the environment. This framework includes a demising Landlord. pier on either side of the Tenant storefront in cases where a Tenant is demised between column grids. The Tenant shall finish any side of the demising pier that faces the store interior at the Tenant’s expense. Retail Criteria Manual | 15 2.0 DESIGN GUIDELINE Storefront Design STOREFRONT CLOSURE Tenant shall provide a closure to their premises at • Fully Glazed and Hinged Doors : Doors that swing behind the storefront closure line. Sliding doors the Tenant’s expense; open storefronts will not be towards the public area may not swing past the shall be enclosed into a pocket, become the permitted. It is the Tenant’s responsibility to ensure store’s lease line into the Mall common area or enclosures in the rear of the display window, that the selected closure system meets all applicable beyond the adjacent storefront surfaces into the or stack one behind the other on the Tenant’s building codes and fire/life safety requirements. flow of traffic. side of the storefront. All door tracks are to be Tenants shall design their storefront to incorporate one of the following two closure systems. • Horizontal Sliding Doors: Fully glazed horizontal recessed single track at the opening and mounted sliding doors, in equal segments, located at or flush with finish floors on either side of the track. No depressions are permitted in the floor slab for this or any other purpose. The sliding doors closure may not be feasible for Tenant with limited frontage. 16 | Westfield Oakridge 2.0 DESIGN GUIDELINE Storefront Design Tenant shall verify sliding doors requirements with local The use of any other closure system is not permitted USE OF THE FOLLOWING CLOSURE building and fire department. Fully glazed and hinged unless previously approved, in writing, by the TYPES ARE PROHIBITED: entrance doors. Any storefront entry door, which Landlord. • Opaque doors swings towards the public area, shall not be permitted • Rolling Grille doors to swing past the store’s lease line (or storefront zone) • Standard aluminum framed doors into the public space or beyond adjacent storefront surfaces into the flow of traffic. STOREFR ONT CLOSURE Retail Criteria Manual | 17 2.0 DESIGN GUIDELINE Store Interiors STORE INTERIORS Store interiors at the Westfield mall should project DESIGN CONTROL ZONE a high standard of presentation equal to the The Design Control Zone is the entire sales area of storefront and the two must be compatible in their the Tenant space, unless otherwise noted. For shallow design. All interior treatments are subject to the spaces, the Design Control Zone may be shortened approval of Landlord as they pertain to durability and on a case by case basis; this determination is up to the appropriateness to overall image of the project. sole discretion of the Landlord. Since the Design Control Zone receives the greatest exposure, special attention must be given to materials, colors, lighting, signage, merchandising, displays, and fixtures. • Ceiling must be painted gypsum board or other hard surface material • Acoustical tile is not permitted • A hard surface floor treatment (marble, granite, limestone, terrazzo, porcelain tile or wood) is required within the Design Control Zone • All lighting within the design control zone must be recessed into the ceiling. Track fixtures may not be used unless they are recessed into a coffer and not visible from the Mall common area • Cash wrap may not be located within this zone. • Slat wall, plastic laminate fixtures, grid displays, and mirrors are prohibited within this area STORE INTERIORS 18 | Westfield Oakridge • Sprinkler heads must be fully recessed with a cover plate painted to match ceiling color. 2.0 DESIGN GUIDELINE Store Interiors V I S U A L P R E S E N TAT I O N A N D MERCHANDISING Strong visual presentation and merchandising are • Cash wraps shall provide a recess for cash registers. essential and integral components of store design. • Trash containers and supplies shall be concealed Displays in the storefront and within the interior • Displays are not permitted beyond the lease line should be bold, strong and imaginative. Tenants are • Visible stacks of inventory, lengthy rows of encouraged to retain a visual presentation design clothing racks, folding tables, cluttered entrances consultant to assist in providing the most effective or merchandise set on the floor are not permitted merchandising concept. Tenants shall install custom • Use of the following material are prohibited: designed and color-coordinated fixtures including, but - slat wall not limited to the following: - grid racks surface mounted to drywall • Cash wrap/counter • Display counters and shelves • Wall cabinets • Showcases • Pedestals, platforms, tables, etc. • Manufactured wall display systems • Changing rooms (where applicable) • Fixtures shall not be overstocked. Tenant’s drawings shall indicate fixture quantities, quality, location, details and finishes. • Chrome racks, rounders, four-ways and basic display tables are not acceptable. • All standards for shelves and fixtures shall be recessed V I S U A L P R E S E N TAT I O N AND MERCHANDISING Retail Criteria Manual | 19 2.0 DESIGN GUIDELINE Store Interiors V I S U A L P R E S E N TAT I O N B E S T • Design PRACTICES concept that incorporates sensory elements-sight, touch and smell (if applicable) BE DISTINCTIVE “In a world where you can find identical merchandise in multiple stores, design layout and presentation become key differentiating factors” The following steps will help you design and “The last thing the customer needs is another store that looks just like all the others” • What kinds of customers do you want to attract? effectively merchandise your retail space: • Who is your customer? • What is the image and profile of the location? • Who is your competitor and why are you different? C U S TO M E R H A B I T S • People visually scan at eye level, about 5 feet. • The optimum buying height is at eye and hand TA K E A S T R AT E G I C A P P R O A C H level. • People walk toward the right. • Most People are right handed. • People are sensory stimulated - Sight, Sound, Touch and Smell Key planning factors for: • understanding traffic flow! • Where to place brand identity and graphics? • where to place best sellers? • Where and what do you want the costumer to pick-up first? V I S U A L P R E S E N TAT I O N BEST FRACTICES 20 | Westfield Oakridge 2.0 DESIGN GUIDELINE Store Interiors • Sight Lines- The design needs to ensure that the customer can see around, over, or through the merchandise presentation. through to the back presentation. • Use this principal when designing and placing all key elements into your design. • Tell merchandise stories that target you customer, make it easy to view your assortment. • Give your best-selling merchandise the most favorable display space. • A haphazard approach to product placement and layout generates less than desired results. • In order to position every item in its proper location, you must have a far more detailed plan, not the usual -“It was the only place left available, so that’s were it ended up!” Use of Color Color Impact - the eye is naturally drawn to colorful MERCHANDISING presentations and the most effective technique is to “The merchandise is the hero, the design is the WOW factor and signs are the enhancement” create a balanced color flow. • Good design embraces a story or a theme • Keep merchandise presentations simple • Colors should flow from light to dark and dark to light within product groupings. • The choice of color in your design concept plays • Focus on best sellers/hot items a key factor in differentiating you and your • Integrate graphic images and information that competition. targets your customer’s attention Site-Line • This diagram demonstrates best practice for floor to wall site-line presentation. Customer has a clear view, front to back, using the Triangle or Pyramid principle. • The merchandise display story at the front carries Retail Criteria Manual | 21 2.0 DESIGN GUIDELINE Store Interiors Choose the merchandise • Determine how many items will be placed on to generate new interest. D E S I G N E VA LUAT I O N - Impulse items - Unplanned purchase items/ - S E E I T F R O M T H E E Y E S O F T H E CO S T U M E R add on sales. POS or RMU locations is the display. • Develop a plan-o-gram. “Less can be more” prime placement for these items. meet the following goals: • Have a plan that highlights best sellers, establish core basics and trend (newness) product flow. • Categorize/group merchandise by color, style, Select display props - Best Seller - Think of the selling space in impacts your perceived product value and your $dollars. The best selling items deserve the customer shopping experience. • Select props that enhance, elevate and support high rent location. - Demand Merchandise- Items that ustomers your merchandise assortment. • Incorporate these display elements into your keep coming back for. Place impulse - • Is it focused on merchandise? • Understanding your traffic flow, does your • Choose the right display elements- This greatly shape, material Does your design and merchandise placement overall design concept. related items near or with you demand items customer see what you want them to see first? • Does it enhance the surrounding environment? • Does it grab customers’ attention? • Does it target your customer? • Does it differentiate you from your competition? • Is it easy to shop? • Are signs clear and easy to read? • Is the display neat and clean? 22 | Westfield Oakridge 2.0 DESIGN GUIDELINE Store Interiors FLOORING Floor treatments can assist in defining areas, act as a • Hardwood floors are acceptable if suitable directional indicator, and encourage desired circulation finishes are selected. Inexpensive parquet squares patterns throughout the space. Hard surface floor and laminated wood floor treatments are not • Indoor/outdoor carpet is not permitted finishes are required in all public (sales) areas of the acceptable. • Quarry tile is not permitted within the sales area. Tenant’s space. The use of carpet as an accent element • Carpet used as inserts, borders, in connection with to define sales spaces shall be considered on a case wood, stone, and ceramic tile is permitted. Direct by case basis and is subject to Landlord’s written glue down is preferred to carpeting with a pad. approval. • Floor materials should be limited to the line of the storefront and not extend into the public area or E N C O U R A G E D F L O O R I N G M AT E R I A L S : in recessed storefront areas. USE OF THE FOLLOWING FLOORING M AT E R I A L S A R E P R O H I B I T E D : It is permitted in back-of-house areas only • Vinyl tile and vinyl or rubber bases are not permitted within the sales area. They are permitted in back-of-house areas only • Laminate flooring will not be permitted in the sales area • A hard surface floor treatment (marble, granite, • All finishes must be flush with one another with limestone, terrazzo, stained concrete, ceramic no tripping hazards. Lips of more than 1/16” or porcelain tile, wood) is required within the and slopes of more than 1/2” per foot are not storefront Design Control Zone. Vinyl or imitation acceptable. • Tenant floor materials may not extend into the public area or in recessed storefront areas • Square tiles (i.e. 4”x4”, 6”x6”, 18”x18”) materials are not acceptable. • The Landlord shall provide common area flooring material to the lease line. The Tenant must ensure, at its sole cost and expense, that the Landlord’s common area floor finish abuts the Storefront and is carried into entry vestibules to the storefront closure line. (See transition detail in Technical Criteria). FLOORING Retail Criteria Manual | 23 2.0 DESIGN GUIDELINE Store Interiors C E I LI NG WA L L S A store concept can be established in the ceiling plane • Innovative suspended ceiling systems will be • All interior partitions must be finished with with regards to identity, character and unique-ness. considered by the Landlord on a case by case suitable materials whether exposed to the public The Landlord encourages Tenants to be particularly basis and is subject to Landlord’s written approval. or not. innovative in articulating ceilings with raised, dropped, Standard 2x2 or 2x4 Acoustical Ceiling systems will vaulted or covered treatments. Use of a variety of not be permitted within the public (sales) areas. ceiling materials is encouraged within the store interior • The use of open ceilings will be considered on (including gypsum board, wood and metal). a case by case basis as approved by building • Ceiling heights shall be maximized to provide department. If approved, Landlord may specify a spacious interior. Ceiling heights within the colors and treatments of elements that are Storefront shall not be lower than the top of the exposed. storefront glazing. Tenants should refer to the Technical criteria for specific zone in which space • Acceptable finishes include, but are not limited to, commercial grade wallpaper, contact vinyl materials, and flame resistant paneling in wood, metal, stone or fabric. • Painted gypsum board may be acceptable when framed with other elements to protect all corners. • The rear wall of the sales area is an important feature of the overall design concept and is often a focal point for displays, signage and merchandise; is located. design consideration should be given to this area. • Where the interior ceiling is lower than the storefront height, careful attention shall be given to the transitions between ceiling heights. Dropped fascias at right angles to the ceilings are encouraged and gradual transitions with lit coves U S E O F T H E F O L LO W I N G WA L L M AT E R I A L S A R E P R O H I B I T E D : • Inexpensive paneling, simulated wood laminates, corkboard, carpeting and pegboard are not encouraged. • All ceilings in the public sales area must be constructed of painted gypsum board or other hard surface materials and must be integrated with other acceptable materials. acceptable. • Excessive use of mirrors or slat panels on walls and columns is not acceptable. • Entries and doors to storage/ stock areas should not be placed in customers’ direct line of sight. • Acoustical Ceiling Tiles are not permitted in the sales area. 24 | Westfield Oakridge 2.0 DESIGN GUIDELINE Store Interiors LIGHTING Lighting sources and fixture types must be carefully • Track fixtures are permitted if they are not visible selected in order to create a variety of ambient, from the Public Zone and are contained within a decorative and accent illumination. The Landlord light pocket in the window display. encourages the Tenant to retain a lighting design consultant to assist in providing the most effective lighting concept. STOREFRONT LIGHTING REQUIREMENTS AND RESTRICTIONS: • All storefront lighting shall operate during mall hours and shall be controlled by a time clock. • Decorative Metal Halide spotlighting within storefront display areas is encouraged. • Exposed Neon signage is not permitted. • Direct visual exposure of lamps is prohibited. • All visible lighting is to be glare free. • All lighting of storefront and signage is to be provided by Tenants. INTERIOR LIGHTING REQUIREMENTS & RESTRICTIONS: • Specialty fixtures that can be suspended off walls or store fixtures and pendant fixtures that add definition are encouraged. • Dramatic lighting of the ceiling and wall planes is encouraged. • Occupancy sensors are required in all back of house areas to control lighting. LIGHTING Retail Criteria Manual | 25 2.0 DESIGN GUIDELINE Store Interiors SECURITY DEVICES ADDITIONAL REQUIREMENTS Freestanding Tenant security devices or security • Tenant shall provide accessible facilities as system, if any, shall not be installed or placed in required by governing codes and The Americans operation unless the Tenant has specifically received with Disabilities Act (ADA) whichever is more Landlord’s prior written consent as to the size, location, stringent. and design. • The Tenant shall not disturb, disrupt, or modify The use of concealed or underground security systems the building’s structural system, unless approved is required. in writing by the Landlord, and the Landlord’s Structural Engineer. The Tenant shall also ensure that finishes remain unimpaired. • All Tenants must specify dual flush toilets, touch free faucets and waterless urinals (if applicable) in their rest rooms as outlined in the criteria. Tenants remodeling an existing space that plan to reuse the existing rest room must replace old fixtures with those outlined above. EXIT AND ENTRANCES 26 | Westfield Oakridge 2.0 DESIGN GUIDELINE Store Signage/Blade Sign and Graphics STORE SIGNAGE(BLADE SIGN) AND GRAPHICS The purpose of the storefront signage and graphics design criteria is to encourage the design of Retail Tenant SIGNAGE DESIGN PHILOSOPHY signage and ensure it is appropriate for the store and the surrounding context, contributing to the Center’s Unlike many other retail centers, the image and design image and character, and is visually attractive. Consequently, creative interpretation of the following criteria is of Westfield malls warrants a unique and original encouraged. approach to signage and graphics. The primary intent of these Store Signage and Graphics Design Criteria is Please note that in addition to these Criteria, Tenants may also be required to adhere to Specific Design Criteria to enhance this image by providing the groundwork pertaining to signage and graphics designated for Tenants within various districts or zones of the Westfield mall. for imaginative, innovative and avant-garde graphics and signage for each shop and their storefront. Each Tenant is encouraged to develop signage and graphics that are bold and dynamic in image, color, materials, and design. Signage should not only incorporate text that identifies the Tenant, but also graphics and forms that indicate identity, character, and image. SIGNAGE Retail Criteria Manual | 27 2.0 DESIGN GUIDELINE Store Signage/Blade Sign and Graphics SIGNAGE AND GRAPHICS All graphics and signage shall be professionally Vinyl or other appliqués to the interior face of the encouraged to explore innovative use of graphics and assembled and displayed in a first-class manner. Any Storefront glazing must be submitted in the Tenant’s technology as both a store signage and marketing hand-written signage will not be allowed. signage package for Landlord approval. Graphics on element. the exterior face of glazing will not be permitted. Tenants with higher storefronts should consider the The use of graphics at the storefront and in display use of back painted glass surfaces with branding or windows adds a vibrant and possibly dynamic other graphics along the upper opaque portions of element to the design of the retail space. Tenants are their storefronts. GRAPHICS 28 | Westfield Oakridge 2.0 DESIGN GUIDELINE Store Signage/Blade Sign and Graphics STORE SIGNAGE AND GRAPHIC GUIDELINES used in the development of all signage and graphics architecture, leaving sufficient margins and elements unless otherwise noted: “You have three to five seconds to tell the customer what you want them to know.” - Signs should be brief and easy to read. - ducate the customer about fashion trends, price, value, or brand identity. • All signs must fit comfortably into their storefront • Signage and environmental graphics must be negative space on all sides. Thickness, height, conceived as an integral part of the design so they and colors of sign lettering and graphics must be do not appear as an afterthought application. visually balanced and in proportion with other signs within the project. The Individual letter • Primary storefront identification shall be limited to Tenant’s trade name, as approved in the Lease, or height may not exceed 18” high or not exceed 50% total width of the storefront. as otherwise approved in writing by Landlord. • All illuminated signs must be controlled by - Avoid over-signing. Be very strategic in sign placement. • Nationally recognized Tenants may use a crest, shield, logo, or other established corporate Tenant’s time clock and illuminated during general operating hours as defined by the Landlord. insignias, but are encouraged to incorporate them The following are general graphic guidelines to be in a three dimensional approach befitting of the image of the district in which they are located. • All submitted Tenant shop and storefront elevations need to illustrate proposed signage in each phase of the presentation. • All signs shall be presented to the Landlord for approval prior to commencement of fabrication. • All signage must be placed out of reach. • Signage and graphics applied directly to the storefront glass must have matching letters and features on both sides of the glass to create a finish look when viewed from either side. • Linear footage of signage should not exceed more than one half the total width of the storefront. • All signage lighting must be baffled or concealed. • Exposed signage lamps and fixtures are subject to approval by the Landlord. • Light leaks will not be permitted. Retail Criteria Manual | 29 2.0 DESIGN GUIDELINE Store Signage/Blade Sign and Graphics • All “UL” labels to be placed out of public’s view. • No “weep holes” unless exterior • Individual pin mounted letters may project past the lease line up to 6” and must be placed no less than 10’-0” AFF. The Tenant must verify signage complies with all local codes and jurisdictions. • Sign cabinets or boxes must be recessed into the storefront, flush with the lease line and have a faceplate that matches the adjacent storefront finish material. Such signage applications may not project past the lease line. 30 | Westfield Oakridge 2.0 Design Guideline Store Signage/Blade Sign and Graphics ACCEPTED SIGNAGE APPROACHES AND TYPES • Mixed media BLADE SIGN (INTERIOR) • Dimensional shapes and forms of metal, signs incorporating multi- dimensional forms and combinations of colors, shapes, materials, and lighting. • Contemporary elements to create an avantgarde appearance. • Application of innovative technologies. • Dimensional letter forms with seamless edge treatments hardwood, glass, or other material with a permanent appearance. • Dimensional geometric shapes and threedimensional forms. • Glazed ceramic tile work forming patterns and/ or fields. • Fiber Optic and L.E.D. illumination • Silhouette illumination • Front lighting, i.e., billboard lighting • Cut or fabricated steel, painted or unfinished. • Channel letters with light transmitting acrylic • Polished metal following criteria: • 33” long x 15” high x 3” deep • Reverse channel lettering • Etched metal or glass, sandblasted glass Each Tenant blade sign should conform to the • Sign must be double sided • Tenant to brand sign with their signature color and finish • Mounting height is 10ft above finished floor to the top of the sign letters are allowable for Tenants with streetfacing storefronts only. Blade sign Retail Criteria Manual | 31 2.0 DESIGN GUIDELINE Store Signage/Blade Sign and Graphics P R O H I B I T E D S I G N A P P R OAC H E S A N D T YP E S • Mounting to be flushed to storefront • Internally illuminated awnings with or without • Check zone to determine mounting justification to left or right of storefront signage • Internally illuminated channel letters with plexi face and trim cap. • Sign must be UL listed • Neon signage will not be permitted • Internally illuminated: - reversed channel letters • Cloth, paper, cardboard, stickers, or decals - push through letters • Noise-making signs • Luminous vacuum formed letters • Temporary wall signs, window signs, pennants, banners, flags, inflatable displays, or sandwich boards. • Cloth, paper, cardboard or foam signs, or decals hung around on or behind storefronts. • Animated signs: signs consisting of anything swinging, rotating, flashing, blinking, scintillating, • Sign contractor is responsible to insure that sign is on separate circuit and on 7 day time clock set to Westfield mall requirements. Sign must have provisions to be turned off during daylight hours. • Conventional plastic faced box or cabinet signs strobing, including any moving electronic message • Formed plastic or injection molded plastic signs boards or centers, or temporary lighting, such as • Channel letters with light transmitting acrylic but not limited to search, flood, or fluorescent gel faces. • The following sing types are not allowed at any location in the storefront: - Box signs (light box) with plexi face panel - plexi face letters - Signs made of paper, fabric or sheet of acrylic - Moving, rotaing, or flashing signs - Credit card signs or symbols - Any other materials and/or designs deemed unsuitable by Landlord GRAPHICS 32 | Westfield Oakridge lights. 2.0 DESIGN GUIDELINE Exterior Storefronts EXTERIOR STOREFRONTS Westfield malls contain an exterior Tenant presence that engages the street in a manner similar to other revitalized areas of the locale. The design of these • Exterior Tenants are encouraged to engage GENERAL DESIGN GUIDELINES • Entry doors must be at least 10’-0” in height and glass, metals or wood. The use of innovative fabric be fully glazed. canopy awnings will be considered on a case by Tenants’ storefronts plays a large role in the overall presentation of the project at these exterior faces. • Tenants must use hinged entry doors. The use of innovative sliding or folding doors (vertical and Tenants with exterior conditions must carefully review horizontal) will be considered on a case by case the base building design as well as that of neighboring basis. Tenants to ensure that its design complements the designs should incorporate horizontal, vertical or framed design elements. case basis and must be approved in writing by Landlord prior to installation. • Awnings/canopies must occur between 10’-0” and 13’-0” AFF and may extend past the lease line up • Vertical mullions will not be permitted. Center’s aesthetic and does not conflict with the storefronts of neighboring Tenants. Generally speaking, horizontal awning or canopy designs incorporating • Tenants should perform a solar study for the façade and incorporate solar shading as needed to minimize heat gain through storefront glazing. • Tenants must use materials that complement the center’s surrounding material palette. Materials should be panelized, i.e., framed, inside of the façade to complement the design aesthetic of the to 15’-0”. • Awning/canopy placement must take into account the storefront design of adjacent Tenants. Tenants may not install awning/canopy element at the same height as an adjacent Tenant. • Tenants with designated patio areas must provide plans and sections illustrating railing placement in relationship to the storefront. base building. Retail Criteria Manual | 33 2.0 DESIGN GUIDELINE Exterior Storefronts • For service or café Tenants without designated patio areas, incorporating small outside bistro seating underneath awnings/canopies is encouraged. These seating areas should be partially recessed behind the lease line and may partially extend into the sidewalk. Tenants should coordinate with Landlord on specific dimensions of such seating areas. • Tenants may incorporate blade signs into the exterior facade. Signage must be designed for outdoor use and meet all applicable building codes. • Standard aluminum storefront systems are not permitted. Westfield encourages innovative approaches to retail design. Concepts that deviate from these criteria must be submitted to the Landlord for review and must be approved, in writing, prior to construction or installation. 34 | Westfield Oakridge 3.0 STOREFRONT ZONES/ BLADE SIGN ZONES Retail Criteria Manual | 35 3.0 STOREFRONT / BL ADE SIGN ZONES Storefront Zoning Plan : Level 1 * refer to details in Section 4.0 Zone 1 Storefront : 13’-9” high Zone 4 Storefront : 12’-6” high Zone 8 Storefront : 15’-3” high Zone 8 Storefront : See Dining Terrrace Criteria * Some storefront heights may vary, Tenant to consult Landlord and/or perform a field survey 36 | Westfield Oakridge 3.0 STOREFRONT / BL ADE SIGN ZONES Blade Sign Zoning Plan : Level 1 Blade Sign Zone : Required Rest of Area : Optional Retail Criteria Manual | 37 4.0 TECHNICAL CRITERIA -ARCHITECTURAL 38 | Westfield Oakridge 4.0 T ECHNIC AL CRI T ERIA The following guidelines are specific to the various zones and storefront types at Westfield Oakridge. In addition to the design guidelines outlined in Section 2.0 of these criteria, Tenants must adhere to the zone specific criteria defined in this section. The storefront sections and elevations contained in these criteria are for reference use only; the Tenant’s design team must verify the conditions of the space they are designing for thorough site surveys . In the event that the criteria in this section conflict with those outlined in Section 2.0, those in this section will govern. In addition to the design guidelines outlined in U S E O F T H E F O L L O W I N G M AT E R I A L S I S Section 2 of these criteria, the following criteria apply PROHIBITED: • Non illuminated letters applied to the face of to spaces located in this area of the center: • Painted Drywall transom glazing above the entry doors • Plywood • Storefront glazing to have a height that varies due to sloping floor and bulkhead condition (See Storefront Section Detail). • Tenants in this zone shall have a hinged or sliding entry door height of 10’-0” or higher. Doors may SIGNAGE GUIDELINES: • Sign bands mounted on interior soffit of space behind full height glazing • Stucco • Unfinished Metals • Vertical sign columns (illuminated or non- • No portion of the storefront may be recessed behind the lease line except for entry vestibules. • Illuminated signage incorporated into entry not swing out into common area past leaseline. • Tenant to provide rendered storefront elevation as part of its drawing submittal to Landlord. • The use of opaque materials above or beside • Illuminated signage incorporated into storefront. illuminated) adjacent to entry doors portals entry doors or for signage backgrounds will be considered by Landlord on a case by case basis. • Storefronts must maintain 90% transparency along the lease line plane. • Portions of existing mall bulkhead to be demolished by Tenant (Verify In Field). • Bottom of tenant ceiling to be 11’-0” AFF minimum. Retail Criteria Manual | 39 4.0 T ECHNIC AL CRI T ERIA ARCHITEC TURAL REQUIREMENTS FOR TENANT ’S STOREFRONT DESIGN WOOD CEILING PANELS WOOD BEAMS G ABLE C EILING LIGHTED COFFER SLOT SKYLIGHT LIM ESTO NE FLO O R East /West Streets; The east west streets are areas of warmth, material richness and refinement. A series of gabled ceilings creates a more intimately scaled environment. Dramatic slot skylights and lighted coffers interrupt the gables and are used to create different lighting effects, add additional visual interest and enhance the intimate scale of this area. In several locations, extensive wood ceilings with interesting compositions of wood beams are utilized to bring additional warmth and material richness to the space. The floor is covered in a pattern of limestone pavers designed to evoke a landscape-like setting. At the court areas, wood is the dominant material and is used extensively in the dramatic ceiling areas and on tilted wood panels at the sidewalls. Around the Macy’s and Sears courts, these sidewall panels are interspersed with limestone ledge-rock clad columns. The floors in these areas are a beautiful mosaic of different limestone pavers. 40 | Westfield Oakridge 4.0 T ECHNIC AL CRI T ERIA ARCHITEC TURAL REQUIREMENTS FOR TENANT ’S STOREFRONT DESIGN CURVED CEILING/LIGHT REFLECTOR SKYLIGHTS WOOD PANELS AUTUMN QUARTZ LEDG LIMESTONE FLOOR North /South Streets; The north south streets are light filled areas articulated as warm yet modern and dynamic spaces. Sensuously curved ceiling panels serve as giant light reflectors for dramatic up-lighting. These curved shapes sweep up to dramatic skylights punctuated with beams that act as light baffles. Ample daylight washes down onto limestone ledge-rock clad columns and tilted wood panels add warmth and refinement to the ceiling zone. The floor is surfaced in warm limestone pavers arranged in a dynamic composition of interlocking shapes. Retail Criteria Manual | 41 LEASE LINE, NO POP-OUT 1/2” Reveal 6” 1/2” Reveal 3” Zone 1 Storefront : 13’-9”H 4.0 T ECHNIC AL CRI T ERIA EXISTING STRUCTURE 3”X6” NEUTRAL PIER BY TENANT, PAINTED WHITE DEMISING WALL STUDS BY LANDLORD. TYPE “X” GYP. BD. TO BE BY TENANT’S GC. NEUTRAL PIER DETAIL TYP. N.T.S. FIRE STROBES(AS OCCURS) TO BE PLACED ON NEUTRAL PIER BY TENANT GC. 3 9 ZONE 1 STOREFRONT ELEVATION TYP. N.T.S. 42 | Westfield Oakridge 1/2” Reveal 6” 1/2” Reveal 3” LEASE LINE, NO POP-OUT EXISTING STRUCTURE 3”X6” NEUTRAL PIER BY TENANT, PAINTED WHITE DEMISING WALL STUDS BY LANDLORD. TYPE “X” GYP. BD. TO BE BY TENANT’S GC. NEUTRAL PIER DETAIL TYP. N.T.S. FIRE STROBES(AS OCCURS) TO BE PLACED ON NEUTRAL PIER BY TENANT GC. 2 6 ZONE 2 STOREFRONT ELEVATION TYP. N.T.S. Retail Criteria Manual | 43 Zone 2 Storefront : 12’-6”H 4.0 T ECHNIC AL CRI T ERIA LEASE LINE, NO POP-OUT 1/2” Reveal 6” 1/2” Reveal 3” Zone 3 Storefront : 15’-3”H 4.0 T ECHNIC AL CRI T ERIA EXISTING STRUCTURE 3”X6” NEUTRAL PIER BY TENANT, PAINTED WHITE DEMISING WALL STUDS BY LANDLORD. TYPE “X” GYP. BD. TO BE BY TENANT’S GC. NEUTRAL PIER DETAIL TYP. N.T.S. FIRE STROBES(AS OCCURS) TO BE PLACED ON NEUTRAL PIER BY TENANT GC. 5 3 ZONE 3 STOREFRONT ELEVATION TYP. N.T.S. 44 | Westfield Oakridge Retail Criteria Manual | 45 5.0 ENGINEERING 46 | Westfield Oakridge 5.0 ENGINEERING Mechanical Design shall refer to landlord’s designated rooftop equipment TENANT WORK : GENERAL plan for their respective location / zone. REQUIREMENTS and ventilation equipment that shall serve the Tenant 1. Tenant shall design an install an air-conditioning and Tenant’s mechanical installation to be completed per Space at all times during business hours. Tenants in heating system to serve the Demised Premises, based all governing codes and all materials shall be new and the new expansion building shall connect to the mains upon the following design conditions. of commercial grade and bare underwriter’s label(s), MECHANICAL DESIGN Tenant shall furnish and install air-conditioning, heating where such labeling applies. Installation shall be for outside air and toilet exhaust where provided by Landlord. Prior to design, Tenant’s engineer to field survey existing conditions within the premises. • Summer: Outside temperature: 94 degrees F (DB), performed by a licensed Mechanical Contractor, in a first-class, workman-like manner. 72 degrees F (WB). • Summer: Inside temperature: 75 degrees F (DB) Tenants with grease, odor or smoke producing operations may be required to install pollution control equipment at tenant’s expense. Such systems shall Tenant’s HVAC system shall be designed and installed 50% R.H. • Actual inside lighting load, people load and to include all areas of the Tenant Space. Only single zone heating-cooling air supply systems are approved equipment load. for this project. be submitted for Landlord’s approval. Tenant’s who • Ventilation load per governing codes. chose not to install such equipment and is found to, • Minimum outside air quantities shall be based in Landlord’s sole discretion, cause related problems on 0.3 CFM per square foot of floor area and/ Tenant shall furnish complete data indicating system with neighboring tenants or main mall system, shall or as required by governing codes, whichever is air balance in the Demised Premises and a certified be required to retrofit their exhaust system to include greater. third-party balance report no more than thirty (30) pollution control at tenant’s sole expense. • Winter: Outside temperature: 30 degrees F (DB). days after opening. • Winter: Inside temperature: 70 degrees F (DB) Other mechanical systems differing from the below (minimum throughout the Demised Premises). system designs shall be reviewed by Landlord on a Provide supplementary heating as required and in location basis. Landlord shall reserve the right to deny compliance with all applicable codes. any variance from this criteria. A. ROOF 1. Roof construction is designed for a live load of 100 • “U” factor of roof is .05 btuh/square foot degrees F. PSF. “U” factor for walls is .189 btuh/square foot F. • Tenant’s engineer is to design and Tenant’s 2. Tenant’s condensing units shall be located on contractor is to install the entire Mechanical the roof in areas specifically designated for such All tenants are required to utilize a split system design System. Any and all rooftop equipment must equipment. These units shall conform to Landlord’s where upon their condensers shall be located on the be located within the allotted roof top space requirements with respect to weight and size, shall roof in an approved location. Tenant’s design engineer provided/designated by landlord. not exceed six feet (6’-0”) in height (installed) and shall SYSTEM DESIGN : SPLIT SYSTEMS Retail Criteria Manual | 47 5.0 ENGINEERING Mechanical Design requirements. furnish a roof platform under each unit. Any additional 5. All roof-mounted equipment shall be curb mounted reinforcement of the roof structure necessary to on raised support platform. Fabricated support support equipment shall be at Tenant’s expense. In platforms for all roof mounted equipment shall be 12. No roof-mounted refrigerant, electrical or water any given bay there shall not be more than two tenant sized to span from centerline to centerline of the piping can be installed horizontally over five feet (5’-0”) condensing units. And no tenant- condensing unit can supports within the equipment bay as approved by total length. rest on a joist supporting another tenant’s unit. Landlord. Tenant shall procure and install walkways to and around all rooftop equipment, as shown in detail. 13. No exhaust(s) can be located within a minimum of This work may be done by Landlord’s roof contractor ten feet (10’-0”) of any supply or air intakes or building and paid by Tenant’s general contractor. openings. roof penetrations shall be reviewed and approved by 6. Tenant’s general contractor shall pay all costs directly 14. No equipment or curbs may be installed closer Landlord in writing. Roof equipment plan submittals to such roofing contractor. than twenty-four inches (24”) from another roof 3. Tenant shall use Landlord’s waterproofing contractor for all waterproofing. Flashing and patching procedures by tenant’s contractor. Locations of all penetration. shall include: • The exact locations dimensioned to Mall column 7. Roof curbs and equipment platform as required. 15. Condensate and refrigeration lines shall be copper grid lines. 8. No wood sleepers of any kind shall be allowed. • The penetration opening size and required pipes. Such pipe shall terminate back into Tenant’s space and be connected above the p-trap of the sink reinforcement of roof deck. 9. Tenant’s general contractor shall provide temporary or to an approved receptor in accordance with the actual weight bearing on the roof at each location weatherproofing for all roof penetrations until requirements of local authorities and Landlord. (including that of equipment, ducts, shafts, etc.). Landlord’s roofing contractor has made the final patch. • The exact size and outline of all curbs with the 16. Electrical conduit may not be run horizontally on • Location of existing Mall structure and additional reinforcement required by Tenant’s equipment 10. No fans, equipment, vents, ducts, or other devices weight. shall be installed on the roof, outside of Tenant’s roof surface. premises, on a demising partition or on exterior wall 17. Site lines of equipment need to be considered from without Landlord approval. ring road. 4. Weatherproofing of all Tenants roof installations 11. Tenant shall locate all Tenant-required grease 18. Access to the Mall roof is restricted to Landlord shall be performed by Landlord’s authorized roofing exhaust units, refrigeration units, fan vents, ducts and personnel and Landlord’s designated contractors waterproofer. other such devices upon a curbed platform or opening only. No Tenant contractor or sub-contractor shall in a manner that complies with Landlord’s installation be permitted on the roof unless permission has been • Details of Landlord-approved curbs and penetration flashing. 48 | Westfield Oakridge 5.0 ENGINEERING Mechanical Design obtained from Mall Management. B. STRUCTURAL 2. Air-handling units, heating equipment, water heaters discharge into the atmosphere via the roof area. Tenant and other equipment located within the Demised is responsible for proper diffusion of the exhaust in Premises shall be floor-mounted, located over the such a manner as to prevent odors from entering air toilet or storage areas on supports or suspended from intakes of other ventilation systems. 1. Tenant, at Tenant’s sole expense, shall engage in the structural beams provided by Tenant, not to exceed services of a structural engineer. maximum live load. D. DUC T WORK 2. Tenant’s structural engineer shall provide plans and 3. Tenant is responsible for isolation of all equipment 1. Hanger-wires, duct-straps, fastening devices, etc. specifications showing the device(s) or equipment so that vibrations and noises are not transmitted. shall be fastened to joists and/or beams above and location(s) and opening(s), 3. installation details, Any noises deemed objectionable by Landlord’s Site conform to the Mechanical Code, SMACNA, and all weight specifications, structural reinforcing details and Representative shall be corrected at Tenant’s expense. ordinances and regulations having jurisdiction. Do not attach anything directly to the upper-level slab or the structural opening details. 4. Tenants are required to install a seven-day time clock roof deck. All ductwork shall be seismically supported 3. Engineering details shall be reviewed by Landlord’s for controlling their HVAC system and be connected to per code. structural engineer. the fire/smoke alarm system. 2. Tenant, at Tenant’s expense, shall enclose any 4. The building’s steel structure is covered with fire 5. Tenant’s air-conditioning system shall be provided required duct shafts located outside the Tenant’s space proofing spray ¾” thick on beams and 1-1/2” thick on with all necessary controls and devices and shall be with a two- (2) hour fire-rated partition. Landlord shall columns. All steel supports required by Tenant to be compatible with the fire alarm system. All controls shall approve and designate the locations of any Tenant- attached to the steel structure shall be clipped, not be in conduit. required duct shaft located outside the demised premises. welded. Tenant shall return all fire proofing within the Premises to the specified thickness providing a 1-hour 6. Tenants in the existing mall building shall procure protective coat, 2-hour at theater and roof. and install a complete forced air toilet exhaust system, 3. Tenant shall specify the type of duct and duct consisting of fan(s), damper(s), ductwork, register, insulation used, as per NFPA standards and Landlord’s capable of twelve (12) air changes per hour or as insurance carrier’s requirements. C. EQUIPMENT required to meet code. 4. All air-conditioning ductwork systems shall be 1. Food Court / Food Service Tenants shall provide and install make-up air and grease exhaust system, 7. Tenants that have odor-producing operations shall designed as low velocity and low pressure. All as required, including all dampers, curbs, exhaust and install a forced-draft ventilation system to maintain distribution ducts are to be per SMACNAlow velocity intake air hood(s). a negative pressure within the Tenant Space and standards and details, including insulated supply air Retail Criteria Manual | 49 5.0 ENGINEERING Mechanical Design distribution to all supply diffusers. Flexible ducts are 9. Tenant is not allowed to remove exterior insulation shall provide proper clearance between the to be used only for termination of duct run to ceiling from Landlord’s main duct. exhauster and the roof. device and shall not exceed six feet (6’-0”) in length. 10. No combustible materials of any type can be 5. All ductwork shall be fabricated from galvanized allowed above suspended ceilings. • Make-up air systems are required for all exhaust systems. The exhaust and make-up air systems shall be electrically interlocked so that one switch sheet metal, stainless steel or black steel in accordance with the standards of American Society of Heating, 11. Tenant shall not use the plenum space above Refrigeration and Air Conditioning Engineers (ASHRAE) ceilings for a return air plenum. All return air above the and Sheet Metal and Air Conditioning Contractors ceilings shall be ducted. activates both. • All cooking-exhaust ducts shall be seamlessly welded and comply with N.F.P.A. #96 requirements. National Association (SMACNA) for low pressure, low velocity ductwork. Plastic liner ductwork with internal FOOD COURT / SERVICE : ADDITIONAL Access doors are required and are to be on the wire reinforcement is not permitted. REQUIREMENT vertical face of the horizontal run, at the bottom of the vertical riser and/or as required by Code. 6. Branches from main low-velocity trunk ductwork 1. The Tenant is responsible for providing their own shall be furnished with splitters, dampers or similar grease exhaust units(s) and all necessary duct work in • A range exhaust hood shall be fabricated in balancing devices in accordance with the standards accordance with the current Uniform Mechanical Code accordance with all codes and shall be at least of SMACNA and the Associated Air Balancing council. and all local jurisdictions having authority. sixteen- (16) gauge or heavier stainless steel, with all joints welded. Dampers shall be provided, as required. 2. All roof top equipment locations must have prior 7. Supply and return ductwork shall be insulated with a written approval from the Landlord. • Kitchen range hood exhaust ducts shall be insulated with fire-rated-type insulation or in minimum of one-inch (1”) thick blanket-type insulation with a vapor barrier. Acoustical liner may be furnished, • All roof-mounted kitchen exhaust fans that handle a rated chase per NFPA standards, Landlord’s as required per NFPA standards, Landlord’s insurance a grease discharge shall have a grease catch pan insurance carrier’s requirements and be UL rated, carrier’s requirements and be UL rated. Flame spread and gutter. Ducts shall be welded sixteen- (16) at specified heat temperature design. Please shall not exceed twenty-five (25) and smoke developed gauge metal enclosed within a two- (2) hour provide complete specification of any type of shall not exceed fifty (50). fire-rated shaft in accordance with all applicable insulation on the submittal drawings. codes. • Hoods and exhaust systems for food processing 8. Air distribution supply registers and/or diffusers shall be designed and specified not to exceed NC level of 30. • Tenants who specify the use of a rooftop shall be protected by a chemical extinguishing centrifugal exhaust fan for their cooking facilities system, as required by Code, installed in 50 | Westfield Oakridge 5.0 ENGINEERING Mechanical Design accordance with all the requirements of the has made the final patch. • Equipment schedules, including air-handling jurisdictional authorities and Landlord’s insurance units, condensing units, roof units, exhaust fans, carrier. All systems shall be integrated with fire/ air devices (diffusers, registers and grilles) and any life safety systems and be furnished with access other equipment used, including manufacturers’ watch and portable fire extinguisher (minimum panels, as required. name and number. size 2A:20BC), wherever any welding is done within • Tenant’s general contractor shall provide a fire the Demised Premises. The person performing the M E C H A N I C A L D R AW I N G R E Q U I R E M E N T Tenant shall submit HVAC plans, prepared by a • Complete details sufficient for construction. fire watch shall remain in the Tenant Space for • Material and equipment specifications. at least one (1) hour after the completion of any • Heating, cooling and ventilation load calculations. welding. licensed mechanical engineer, for Landlord’s review and approval. Contractor and/or equipment supplier W O R K I N G D R AW I N G D E S I G N A N D drawings shall not be permitted. C O O R D I N AT I O N • No roof work of any kind can be allowed prior to an on-site meeting with Landlord’s Tenant Construction Coordinator. Any required roof Tenant’s HVAC drawings shall consist of, but not be The following items shall be noted on Tenant’s plan, for penetrations shall be performed in coordination limited to, the following: clarification: with Landlord’s roofing contractor and as outlined in HVAC Design and Construction Criteria. • Floor plan and/or reflected ceiling plan at one- • Prior to making any pipe or duct roof penetration quarter inch (¼”) scale or larger, including all and/or on • All mechanical equipment, pipes and ducts, ductwork, exhaust systems, hoods, piping and the roof, all the proposed locations and/or penetrating and/or located on roof shall be equipment. penetrations shall match locations, as indicated painted to match color of the existing roof. Use on the Landlord-approved plans and approved by the appropriate coats of primer pre-treatment, Landlord’s construction field coordinator. prior to the final coat. The final coat of the roof • Partial roof plan, if applicable, including positioning of any equipment matching color shall be approved by Landlord’s location of roof-mounted installations and roof penetration details. • Schematic diagram of the HVAC system controls, • All equipment is to be supported from structural Tenant Construction Coordinator. Tenant’s store members. No weight can be placed on the roofing space number shall be permanently stenciled on materials or insulation. one side of the roof-mounted HVAC unit, with minimum three-inch (3”) high letters. including all fire/smoke detection and alarm devices with all manufactures’ model numbers indicated. • Tenant’s general contractor shall be required to furnish temporary weatherproofing of all roof penetrations, until Landlord’s roofing contractor • Tenant contractor is to furnish air-balancing reports for HVAC work. Retail Criteria Manual | 51 5.0 ENGINEERING Mechanical Design 52 | Westfield Oakridge 5.0 ENGINEERING Electrical Design ELECTRICAL DESIGN SYSTEM DESIGN selected by Landlord, for Tenant connection to accordance with Landlord’s criteria as outlined telephone service. in this manual, the latest adopted editions of the • Landlord shall furnish a communications line rack in the rear service corridors for Tenant’s use. NENEC and the requirements of all local authorities having jurisdiction. Materials, electrical products and equipment, including all components shall be new Landlord shall furnish a main electrical switch at a central distribution point located within Landlord’s TENANT WORK : GENERAL and appear on the Underwriters Laboratories list of main electrical room. Tenant shall design and install an REQUIREMENTS approved items. based on 277/480 volt, 3-phase, 4-wire system. A. TENANTS SHALL PROVIDE THE FOLLOWING: 6. Tenant shall install all electrical work necessary for LANDLORD WORK 1. Apply for a meter, per the local utility and as directed premises, including, without limitation, transformers, by Landlord. electrical panels, and disconnect switches. electrical/telephone system to serve the Tenant Space, a complete electrical distribution system within the • Landlord shall provide for Tenant electrical service equipment, located outside the Tenant Space, 2. Telephone wiring from Tenant’s premises to with a capacity of 17WATTS per Square Feet. Landlord’s main telephone backboard B. CONDUIT & WIRIRES utilizing • Landlord shall provide fuses (100 amp. minimum) Landlord’s communications line rack located in the 1. Tenant shall extend Landlord’s conduit, as needed, for Tenants use at Landlord’s metering switchboard service corridors. Tenant shall label all wiring every 20 within the Tenant Space to Tenant’s main disconnect at Tenant’s expense. linear feet within the rack. switch, transformer and/or panel board. from Landlord’s to a location within Tenant’s 3. Tenant shall extend Landlord’s conduit, as needed, 2. Tenant shall install feeder wires through the Demised Premises as determined by Landlord. within the Tenant Space to Tenant’s main disconnect main electrical service conduit and make the final switch, transformer and/or panel board connections to the main electrical switch located • Landlord shall furnish 2” minimum service conduit • If Tenant requires a different size main electrical at the meter section distribution point. Tenant shall switch or service conduits, Landlord may furnish coordinate with Landlord’s electrical contractor. same, if available, at Tenant’s expense. Tenant’s 4. Tenant shall install feeder wires through the electrical engineer shall notify Landlord in writing main electrical service conduit and make the final of any switch or conduit size requirements of connections to the main electrical switch located 3. All main feeder wires from the main electrical meter Tenant that are larger than those existing prior to at the meter section distribution point. Tenant shall section breaker shall be sized to meet NENEC. Main plan submittal. coordinate with Landlord’s electrical contractor service feeders, as a minimum, shall be treated for the sum of all loads, plus twenty-five percent (25%) spare • Landlord shall provide main telephone terminal board at a location outside the Tenant Space, 5. Tenant’s electrical system shall be designed in capacity. Branch circuits connected loads shall not exceed eighty percent (80%) of rated capacity. Retail Criteria Manual | 53 5.0 ENGINEERING Electrical Design 4. Minimum circuit wire size shall be #12AWG, 9. Flexible metal conduit shall be used only for shall match locations, as indicated on the Landlord- excluding control wiring. All main and branch circuitry connections inside casework and as the final approved plans and be approved by Landlord’s on-site wiring shall be copper. All wiring is to have 600-volt connection. (Four feet [4’-0”] maximum length and representative. insulation, Type THW, THWN or THHN for main feeders. minimum one-half inch ½” electrical trade size) to All wiring shall be color coded per NENEC. Same color recessed fixtures or motors and electrical equipment 15. All roof penetrations made by Tenant’s general shall identify same phase throughout the system. that may generate vibration through the conduit contractor shall be subject to Landlord’s approval as system. No BX,AC, or Romex type wiring can be to location and construction details. Weatherproofing, allowed. of any installation, shall be performed by Landlord’s 5. Panel connected loads within the Tenant Space and authorized main feeder conductors (from Landlord meter section roofing contractor. Tenant’s general to panel) shall be balanced within plus or minus ten 10. Furnish liquid-tight flexible conduits for outdoor contractor shall pay all costs directly to such roofing percent (10%) across all phases. installations. Floor boxes shall be watertight with cast contractor. threaded conduit hubs. C. ELECTRICAL PANELS 6. All conduits shall be concealed in finished areas. Minimum conduit shall be one-half inch (½”) trade size. 11. Pull boxes or junction boxes are required to be of Conduit concealed in slab shall be minimum three- minimum twelve- (12) gauge galvanized steel. Boxes 1. As required, provide lock-on devices on panel circuit quarter inch (¾”) trade size. No conduit shall allowed in walls shall be galvanized pressed steel or cast metal. breakers for exit and emergency light and fire/smoke to be installed in the slab unless absolutely necessary. Caulk around boxes to eliminate noise transmission. alarm system. 7. All wiring shall be installed in conduit. Conduit 12. The electrical system serving the Tenant Space 2. Panel connected loads within the demised premises shall be galvanized steel, rigid heavy wall or electrical shall be grounded in accordance with the latest and main feeder conductors from Landlord’s meter metallic tubing. Watertight fittings shall be used where requirements of the NENEC. Step-down transformers section to panel must be balanced within plus or required by code. shall be grounded to the main cold water pipe in the minus 10% across all phases. demised Premises. 3. Lighting panel boards shall be of the three-phase, 8. Conduit hangers, clamps, light fixture supports, etc shall be fastened to bar joists or beams. No attachment 13. Ground fault circuit interrupters shall be installed in four-wire circuit breaker type. Cabinets shall be or support from any roof deck is allowed. Exposed branch circuits, where required by code. constructed of code-gauge steel, having not less than four-inch (4”) gutter space on all sides. Doors shall be conduits shall be in straight lines parallel with or at right angles to column lines or beams and separated 14. Prior to making any conduit, pipe or duct-roof hinged with keyed cylinder locks and all locks shall at least six inches (6”) form water or gas lines, wherever penetration and/or positioning any equipment on the be keyed alike. Circuit breakers shall be the thermal they run alongside or across such lines. roof, all the proposed locations and/or penetrations magnetic type with molded case with all two (2) 54 | Westfield Oakridge 5.0 ENGINEERING Electrical Design and three (3) pole breakers of the common handle grounded in accordance with the latest requirements 9. All devices and equipment in finished areas shall be type. Distribution panels shall be of the convertible of the NENEC. System shall be grounded to the main flush mounted, where possible. type utilizing automatic circuit breakers or fusible cold water pipe in the Demised Premises. 10. No lighting can be installed outside the Tenant disconnect switches that shall be furnished with current limiting fuses. Tenant shall be required to install 3. As required by governing codes, furnish Self- Space, in the common area and/or ceiling for a main circuit breaker or manual disconnect within the contained, battery pack emergency lighting and exit storefront lighting or sign illumination. tenant space. signs throughout the demised Premises. 11. Tenant’s general contractor shall be required 4. Lighting panels shall have quick-lag molded case 4. Motors ½ HP or less shall be 120 volts, single phase. to provide temporary weatherproofing for all roof breakers bolted to buss. Half-size or tandem breakers Motors ¾ HP or more shall be 208 volts, 3 phase or 480 penetrations until Landlord’s roofing contractor has or plug-ins shall not be allowed. Distribution panels volts, 3 phase. made the final patch. break interrupter switches) or molded case circuit 5. Manual or magnetic starters, switches, contacts, 12. If not already provided, tenant’s electrical breaker-type. relays, time switches, safety devices and other controls contractor shall furnish an identification nameplate shall be commercial-type with heavy-duty ratings on Tenant’s main disconnect switch in Landlord’s 5. Furnish a complete typewritten identification and shall be installed in strict conformance with the meter section. Nameplates shall be one-eighth directory card for all branch circuits in the panel door. manufacturer’s recommendations and applicable inch (1/8”) thick plastic, black on white and etched codes. Manual switches used as equipment disconnect letters. The minimum size shall be one inch (1”) with shall have overload protection. only the Tenant’s space number engraved on such, shall be either fusible-type (with quick-make, quick- D. MISC. ITEMS permanently affixed. 1. Transformers may not be suspended from the 6. Tenants are required to utilize electric water heaters structure and are to be floor or floor supported for domestic hot water and electric heaters for space 13. Tenant shall make application to the local utility platform mounted. Dry type transformers shall be heating. for meter and metered electrical service. Tenant shall comply with all the local utility’s guidelines. class H rated, 480 volt primary to 120/208 volt, threephase, four-wire secondary capacity adequate to 7. Engraved phenolic nameplates are required on Application for a temporary electric meter to service Tenant’s requirements. Noise level is limited distribution panels, motor starters, lighting panels and permanent electric meter, including installation to a maximum of fifty (50) DB average, measured at a push button stations, etc. and provisions for same shall be submitted and installation commence within the first week of tenant distance of one foot (1’-0”) form the case, per NENEMA Publication No. TR-1-1960 or latest revision thereof. 8. Provide weatherproof disconnect switch and 120 volt 2. The electrical system serving the Premises shall be duplex service outlet on the roof-mounted HVAC unit. construction start. Retail Criteria Manual | 55 5.0 ENGINEERING Electrical Design 14. Tenant shall provide and install complete telephone 17. All tenant roof equipment shall be properly labeled service support facilities as required by the serving with equipment name and retail space number. Telephone Company. All Tenant telephone equipment Helvetica typeface at 2” high weather proof and fade is to be contained within the Tenant’s space. Tenant resistant lettering. • HVAC control schematic details. • Electrical load summary, including all connected and demand load calculations. shall furnish a telephone backboard, a 120-volt, 20 amp duplex outlet on a separate circuit. Where tenant does D R AW I N G R E Q U I R E M E N T shall provide a 1” conduit from tenant space to service corridor. Tenant to install telephone cables back to • Voltage drop, based on actual loads, shall be indicated on the one line riser diagram for all not have direct access to a service corridor, landlord • Tenant’s electrical drawings shall consist of, but feeders, sub-feeders, per NENEC. not limited to, the following: • Equipment and materials specifications. telephone terminal board. • Electrical floor plan at one-quarter inch (¼”) scale All other tenants to provide 1” conduit sleeve into or larger (for power). details. corridors. Tenant shall make application to the serving Telephone Company for service and shall comply with their requirements. Tenant’s telephone equipment • Smoke exhaust fan control and connection • Reflected ceiling plan at one-quarter inch (¼”) scale or larger (for lighting). W O R K I N G D R AW I N G D E S I G N A N D C O O R D I N AT I O N is not permitted in Landlord’s telephone equipment • Electrical riser diagram, including type and size room. 15. Tenant shall install a local audible smoke alarm in of feeders, fuses, disconnect switches and main The following items shall be note on Tenant’s plan, for breakers. clarification: their storage, preparation and sales area hard wired to Tenant’s electrical system and shall furnish any • Electrical panel(s) schedule, including circuit Prior to making any pipe or duct roof penetration and/ other alarm system as may be required by any local breaker sizes and all connected load calculations. or positioning of any equipment on the roof, all the proposed locations and/or penetrations shall match governmental authority. • Lighting fixture schedule, including type, lamps, locations as indicated on Landlord-approved plans and 16. Tenant’s HVAC system shall be powered off Tenant’s mounting, wattage’s, quantities and manufacturers approved by Landlord’s construction field coordinator. electrical distribution system. Tenant shall provide all catalog number. No roof work of any kind can be performed prior to an on-site meeting with the Tenant Construction power and control wiring, including final connection. System shall be connected to Landlord’s Central Fire Alarm System. • Fire/smoke alarm system controls and interconnections. Coordinator. Any required roof penetrations shall be performed in coordination with Landlord’s roofing contractor, as outlined in HVAC Design and 56 | Westfield Oakridge 5.0 ENGINEERING Electrical Design Construction Criteria. Tenant’s general contractor shall be required to furnish temporary weatherproofing for all roof penetrations, until Landlord’s roofing contractor has made the final patch. Tenant’s general contractor shall provide a fire watch whenever any welding is done within the Tenant Space. The person performing the fire watch shall remain in the Demised Premises for at lest one (1) hour after the completion of any welding. All roof and slab penetrations made by Tenant’s general contractor shall conform to Landlord’s standard criteria and shall be subject to Landlord’s approval as to location and construction details. Weatherproofing of any roof penetrations required by Tenant shall be performed by Landlord’s authorized roofing contractor. Tenant’s general contractor shall pay all such costs, therefore, directly to such roofing contractor upon their demand. Any failure to follow this procedure, and any damages resulting therefrom, shall be at the Tenant’s sole cost and expense. All pipes penetrating and/or located on the roof shall be painted to match the color of the existing roof. Use the appropriate coats of pre-treatment primer prior to the final coat. Final coat of the roof matching color shall be approved by Landlord. Retail Criteria Manual | 57 5.0 ENGINEERING Plumbing Design of the Uniform Plumbing Code with Santa Clara County PLUMBING DESIGN selected by Landlord. SYSTEM DESIGN 3. A sanitary vent service main line and three-inch within this jurisdiction. Tenant shall secure a electric (3”) plugged (T) connection shall be installed at a meter through the local utility company. Amendments and all other codes as may be applicable Tenant shall design and develop a complete plumbing location and elevation selected by Landlord. Tenant system with all the necessary facilities to serve the shall extend its service from tenant’s premises to the 2. Tenants shall saw cut all slab penetrations and ensure Demised Premises. This includes installing a vent and connection location. that they are properly sealed and remain watertight. Provide penetrations as small as possible to minimize waste system, a domestic hot and cold water system and gas system. Tenant shall make all connections to 4. For food court and restaurant tenants, a gas manifold the existing utility services provided by Landlord. shall be installed at a remote location as determined by Landlord. effect on structural systems and/or components. 3. Tenant shall ensure that all slab penetrations within the Tenant Space (and through the roof ) are properly For spaces greater than 1,499 square feet, Tenant shall design, furnish and install a minimum of one (1) 5. For food court tenants, a grease waste service main sealed and remain watertight to prevent possible complete Handicapped accessible toilet room facility and four-inch (4”) plugged (Y) connection shall be water leakage and/or damage. Any damages caused for Tenant’s employees meeting both local and ADA provided at a location and invert elevation as selected from failure to do so shall be at Tenant’s sole risk and requirements. Toilet room shall include at least one by landlord. Food court tenants grease waste shall be expense. (1) water closet, one (1) hand sink (with hot and cold serviced by a common, on site grease interceptor. 4. All roof and slab penetrations made by Tenant water provisions), one (1) floor drain w/ seepage pan 6. For restaurant tenants, a 4” sanitary line will be are subject to Landlord’s approval as to location provided between premises and designate area for and construction details. Weatherproofing of any LANDLORD WORK tenant’s grease interceptor, by tenant. roof penetrations shall be performed by Landlord’s 1. A cold water service distribution system and valved TENANT WORK : GENERAL contractor shall pay for all costs therefore, directly to outlet connection shall be provided for Tenant’s REQUIREMENT such roofing contractor. 1. Tenant shall connect to and extend all piping from 5. All piping, clamps, supports, etc. shall be fastened the existing location, all-sanitary sewer, grease waste to joists or beams. Do not attach anything directly 2. A sanitary sewer service main line and four-inch domestic water. Sanitary vent piping and gas piping (if to the deck, ceiling support system or ductwork (4”) plugged (Y) connection shall be provided for the approved) to the necessary location within the Leased above. Furnish seismic support in compliance with all Demised Premised, at a location and invert elevation Premises. All work shall comply with the latest edition applicable codes. and one (1) sanitary floor clean out. authorized roofing contractor. Tenant’s general Space. The outlet shall be valved, sized and placed at a location determined by Landlord. 58 | Westfield Oakridge 5.0 ENGINEERING Plumbing Design 2. For cold water service Tenant shall: But not into a floor drain. Connect to the existing valved outlet, as provided Hot water heater can set and discharge into, a sealed 7. All exposed piping above Tenant’s ceiling shall be by Landlord, extend piping as required and furnish a sheet metal pan. Pan shall have drain line to a “Y” tail insulated with minimum of one-half inch (½”) glass water sub-meter (if required, registering in gallons), section of lavatory waste pipe, as approved by the fiber with non-combustible UL rated vapor barrier pressure regulator, ground jumper wire and all further Plumbing Inspections Department jacket and insulation shall conform with and/or exceed installations and connections, in accordance with all al fire and smoke ratings perASTME84, NFPA255, UL723 given requirements. 6. Shutoff valves shall be provided at all connections to fixtures. 5. Hot water heater shall be installed inside a water tight sheet metal pan and T&P drain shall run into the and Landlord’s Insurance Carrier. Place the cold water sub-meter assembly at the rear sealed sheet metal pan. Pan shall have drain line into 8. Tenant shall provide steel sleeves when passing pipe portion of the Tenant Space in a readily accessible and a tailpiece section of lavatory or sink waste pipe or as through concrete slabs or wall sections. readable location, at a maximum forty-eight inches approved by the Plumbing Inspections Department. (48”) above the finished floor. B. SANITARY LINES AND VENT PIPING 9. All materials shall be new and of commercial grade and bare underwriter’s label(s), where such labeling 3. Tenant shall provide and install an electric domestic applies. hot-water heater supported from the floor or on a 1. All sanitary sewer and vent piping shall comply with platform above the toilet room with an ASME-approved all governing codes. 10. The entire installation shall be performed by a temperature and pressure relief valve. Discharge licensed plumbing contractor in a first-class, workman- from said hotwater heater temperature and pressure 2. Low flow water closets, urinals, lavatories and like manner. relief valve shall be piped to an approved receptor. At sinks, etc, as approved by the Plumbing Inspections Tenant’s option, instantaneous water heaters may be Department, are to be used. A. DOMESTIC WATATER 1. All cold and hot water piping shall be-type “L” used. Tenant shall furnish drip pans under all water heaters (located above the floor) with a drain piped to 3. Tenant shall provide floor or wall clean-outs at every the floor drain. fifty foot (50’-0”) (minimum) length of sanitary piping, at the most remote end of each sanitary sewer branch seamless hard-drawn copper tubing above ground and type “K” below ground and be in conformance 4. Hot water temperature and Pressure Relief (T&P) and at each change of direction of the waste line that with ASTM B88-48. Fittings are required to be wrought, Valve options: is greater than forty-five (45) degrees. Ready access to the clean out shall be furnished. suitable for 200 psi. Connections to dissimilar materials shall be made with dielectric unions. Joints shall be T & P valve drain line can terminate into mop sink, floor 95-5 tin antimony for 200 psi. sink or other approved Building Department locations. Retail Criteria Manual | 59 5.0 ENGINEERING Plumbing Design 4. Three-inch (3”) floor drains are required in the toilet C. GAS PIPING for gas service to the Tenant Space, comply with their requirements for metering and service. The complete and storage room areas. Trap primers are required. 1. Landlord reserves the right to deny gas service. routing and installation of the piping shall be at Tenant’s sole cost and expense 5. Deep Seal Traps shall be on all fixtures, except those with integral traps. Trap primer shall be provided, if 2. Tenant shall provide and install all gas piping from denoted by Code. Landlord’s valved outlet to Tenant’s space. 7. All gas piping shall be by Tenant and shall be schedule 40 black steel,ASTMA120 with 150 lb. banded 6. Individual hair interceptors shall be installed on all 3. Tenant shall submit load requirements to the local Malleable iron screwed fittings and in compliance sinks, basins and special sanitary units which may in Gas Company for approval. Tenant shall, at Tenant’s with all governing codes and requirements of the any way receive human or animal hair. sole expense, arrange with the utility company for utility company, as it relates to piping and equipment service. All gas regulating and metering facilities and installation and testing methods and procedures. 7. Cast iron traps, hair interceptors, and /or chemically all gas piping from the service meter to the gas fired treated traps as required by code and Landlord for equipment within the premises is at Tenant’s sole cost D. FOOD COURT / FOOD SERVICE use in Tenant’s product processing, hair styling or pet and expense. ADDITIONAL REQUIRMENTS 4. Natural gas service might be available for restaurant 1. Grease interceptors shall be installed by landlord for Tenants for gas-fired cooking, as directed and all food court tenants having pot sinks or any grease- 8. Underground sanitary and vent piping (other than approved by Landlord. Tenant shall notify Landlord of producing appliances discharging into the waste food waste) shall be service weight, cast iron, with such requirement(s) during or prior to the Preliminary system. Tenant shall connect to the four-inch (4”) fittings of the same weight as the pipe. Above ground Plan submission. If available and approved, Tenant grease waste line provided for the space by Landlord. sanitary piping (other than food waste) shall be service shall indicate (on Tenant’s final drawings) the complete weight, cast iron, also with fittings of the same weight design, including the load calculations of the gas 2. The Tenants serving soft drinks, juices, alcoholic as the pipe. system in the Demised Premises. beverages or any corrosive liquid shall use “Durion” stores, shall be procured and installed by Tenant in accordance with code. piping for all below- floor waste lines. 9. All underground sanitary and vent piping shall be 5. The entire piping system and equipment or fixtures service-weight cast-iron, with fittings of the same shall be furnished with automatic and manual shut-off 3. Soft drink chases shall be installed within Tenant’s weight as pipe. PVC use is prohibited underground devices/controls and color-coded or identified as such, premises only. Soda line chase installation within other within the building footprint (per building department). as required. Tenant’s plenum area or within demising walls will not be allowed. All above ground sanitary piping shall be service-weight cast-iron, with fittings of the same weight as the pipe. 6. Tenant shall arrange with the local utility company 60 | Westfield Oakridge 5.0 ENGINEERING Plumbing Design 4. Condensate lines for refrigeration units may not • Specifications including all materials and run horizontally across roof. They shall terminate at equipment with also the manufacturer’s name Tenant’s mopsink or approved receptor. Tenant shall and model number. 3. Tenant’s general contractor shall be required to furnish temporary weatherproofing of all roof be required to furnish copper condensate line. penetrations, until Landlord’s roofing contractor has • Plumbing fixture unit calculations. made the final patch. 5. All restaurants must install their own grease interceptors in an area designated by landlord. P LU M B I N G D R AW I N G R E Q U I R E M E N TS • Schedules of fixtures and equipment including, but not necessarily limited to, water heater, 4. Tenant’s general contractor shall provide a fire watch lavatory, water closet, water meter, gas meter and and portable fire extinguisher (minimum size 2A:20BC), floor drains. wherever any welding is done within the Tenant Space. The person performing the fire watch shall remain in • Tenant’s plumbing drawings shall be submitted for Landlord approval with the Final Working • Isometric diagram of gas system, including all Drawing submittal and shall consist of, but not be equipment locations within the Tenant Space limited to, the following: and at the gas header and meter location placed completion of any welding. on-site meeting with Westfield’s Tenant Construction • Plumbing floor plan at one-quarter inch (¼”) scale Coordinator. Any required roof penetrations shall be • Gas load calculations, as applicable. performed in coordination with Landlord’s roofing piping sizes, equipment locations and plumbing to Landlord’s existing system. the Demised Premises for at least one (1) hour after the 5. No roof work of any kind can be allowed prior to an outside the Demised Premises. or larger, including all plumbing fixtures, proper materials or insulation. W O R K I N G D R AW I N G D E S I G N A N D contractor and as outlined in HVAC Design and C O O R D I N AT I O N Construction Criteria. 1. Prior to making any pipe or duct roof penetration 6. All mechanical equipment, pipes and ducts and/or positioning of any equipment on the roof, all the penetrating and/or located on roof shall be painted to proposed locations and/or penetrations shall match match color of the existing roof. Use the appropriate locations, as indicated on the Landlord-approved coats of primer pre-treatment, prior to the final coat. plans and approved by Landlord’s construction field The final coat of the roof matching color shall be coordinator. approved by Landlord. Tenant’s store space number • Isometric diagram of water system (hot and cold) within the Tenant Space. • Isometric diagram of sanitary system and venting system within the Demised Premises. • All applicable details for floor drains, cleanouts, shall be permanently stenciled on one side of the roof slab and roof penetrations, etc., sufficient for construction. 2. All equipment is to be supported from structural mounted HVAC unit with minimum three-inch (3”) members. No weight can be placed on the roofing high letters. Retail Criteria Manual | 61 5.0 ENGINEERING Plumbing Design 62 | Westfield Oakridge 5.0 ENGINEERING Plumbing Design Retail Criteria Manual | 63 5.0 ENGINEERING Smoke / Fire Alarm Design SMOKE AND FIRE ALARM DESIGN hours of reserved power. • All zones must be clearly labeled on fire alarm SYSTEM DESIGN H. Tamper switch. 2. SEQUENCE OF OPERATION control panel. If Tenant’s Demised Premises Westfield Shopping town Oakridge utilizes an occupies two levels, zones must alarm each level A. Shut down/loss of power to Tenant’s panel shall addressable system to which individual tenant fire independently. initiate a trouble signal at the Tenant’s panel and Landlord’s main fire alarm panel. alarm systems are to be interfaced via Tenant installed B. Ceiling Smoke Detectors located as follows: addressable monitor devices. LANDLORD WORK Tenant’s sales area within 10 feet of storefront or lease B. Trouble incurred due to a defective device shall line. initiate a trouble signal at the Tenant’s panel and Landlord’s main fire alarm panel. Landlord shall provide a fire alarm system, as follows: • A central fire alarm system serving the common • Tenant’s stockroom ceiling. • Where required by local jurisdictional authorities. C. Activation of the Tenant’s water flow switch shall • Heat detectors are to be utilized in lieu of smoke send a signal to Tenant’s fire alarm control panel that detectors in food court demised premises. Shopping town. • A fire alarm control and monitoring module for Tenant’s system connection, as located by C. Duct smoke detectors as required by the Uniform Mechanical Code. shall then: • Produce an alarm at the Tenant’s panel and Landlord’s main fire alarm panel. • Shut down Tenant’s HVAC system. Landlord. TENANT WORK : GENERAL D. A water-flow switch located in sprinkler main at • Activate Tenant’s strobe light. point of entry into Tenant’s Demised Premises. • Start the common mall smoke zone exhaust system outside the tenant storefront. REQUIREMENTS E. A recessed strobe light located at storefront ceiling 1. Tenant shall install within Tenant’s Premises a Class adjacent to the storefront lease line and visible from D. Activation of the ceiling smoke detectors shall send B fire alarm system within Tenants Demised Premises. the Shopping town Commons. a signal to Tenant’s fire alarm control panel that shall then: Tenant shall engage in the services of the Landlord designated Fire Alarm Installer for connection to the F. HVAC shutdown relay. • Activate an alarm at the Tenant’s panel and main alarm panel. G. Wiring as required by Fire Alarm Contractor. A. A fire alarm control panel with audible alarm with 24 64 | Westfield Oakridge Landlord’s main fire alarm panel. • Shut down Tenant’s HVAC system. 5.0 ENGINEERING Smoke / Fire Alarm Design • Turn on the Tenant’s strobe light. The connection to Landlord’s alarm system is a onepoint connection and shall send a signal for either E. Activation of the duct smoke detector shall send smoke detector activation or use of Tenant’s Ansal a trouble signal to Tenant’s fire alarm control panel system. • Activate an alarm at the Tenant’s panel and Landlord’s main fire alarm panel. • Shut down Tenant’s HVAC system and Exhaust / Make-up air system. • Initiate the Tenant’s strobe light. which shall: SEQUENCE OF OPERATION E. Activation of the duct smoke detector shall send a • Initiate a trouble signal at Tenant’s panel and Landlord’s main fire alarm panel. A. Shut down/loss of power to Tenant’s panel shall trouble signal to Tenant’s fire alarm control panel that • Shut down Tenant’s HVAC system. initiate a trouble signal at the Tenant’s panel and shall: • Activate the Tenant’s strobe light. Landlord’s main fire alarm panel. • Initiate a trouble signal at Tenant’s panel and Landlord’s main fire alarm panel. F. A triggering of the kitchen-hood fire-suppression B. Trouble incurred due to a defective device shall system then would send an alarm signal directly to initiate a trouble signal at the Tenant’s panel and • Turn off Tenant’s HVAC system. Landlord’s main fire alarm panel. Landlord’s main fire alarm panel. • Activate the Tenant’s strobe light. • A triggering of the kitchen-hood fire-suppression FOOD COURT / SERVICE : ADDITIONAL C. Activation of the Tenant’s water flow switch shall REQUIREMENTS send a signal to Tenant’s fire alarm control panel that system shall • Send an alarm signal directly to Landlord’s main fire alarm panel. shall then: Tenant’s detection system shall include ceilingmounted smoke detectors in the food preparation area and sales area, a heat detector in hood and the capability of sending a signal of operation of the hood Ansal system. • Produce an alarm at the Tenant’s panel and FINAL TESTING OF FIRE ALARM SYSTEM Landlord’s main fire alarm panel. • Shut down Tenant’s HVAC system and Exhaust / Each Tenant’s fire alarm system shall be final tested by Make-up air system. • Activate Tenant’s strobe light. the Local Building and Fire Marshal and witnessed by The cooking exhaust hood and make-up air shall be • Start the Tenant Zone smoke control exhaust Landlord’s on-site representative. wired so that the operation of one shall activate the system and the Mall outside air-supply system. Written approval of the Tenant’s system and operation other. The activation of the Tenant’s Ansal system shall automatically shut down the Tenant’s HVAC, exhaust D. Activation of the ceiling heat detectors shall send shall be obtained from the Building Department and make-up air systems. a signal to Tenant’s fire alarm control panel that shall and Fire Marshall’s offices and a copy submitted to then: Landlord’s on-site representative. Retail Criteria Manual | 65 5.0 ENGINEERING Smoke / Fire Alarm Design D R AW I N G R E Q U I R E M E N T S Tenant’s fire alarm system drawings shall consist of, but not be limited to, the following: • A fire alarm system schematic shall be incorporated as part of the electrical drawings. • Location and wiring of equipment shall be indicated on the electrical floor and reflected ceiling plans (i.e., strobe light, smoke detectors, fire alarm control panel, etc.). • As-built drawings • A location map showing duct detector and shutoff valve shall be affixed on the rear door and be protected by a Plexiglas cover. Minimum size is 8½” x 11”. 66 | Westfield Oakridge 5.0 ENGINEERING Fire Suppression Design FIRE SUPPRESSION DESIGN SYSTEM DESIGN Tenant shall install a complete sprinkler system for 4. All piping shall be supported from beams/joists only. premises in accordance with all requirements and all Do not attach anything directly to the upper lever slab applicable codes. or roof deck. Fastening and/or suspension devices shall be attached to the building structure only. Tenant shall connect a fire protection system, to either Landlord shall reserve the right to furnish and install a Landlord’s sprinkler main or a branch line connection sprinkler system for tenant’s premises in compliance 5. All piping shall be designed in accordance with NFPA to the Demised Premises, using approved mechanical with all codes for the shell premises at tenant’s sole #13 and installed per Landlord’s insurance carrier’s fittings. Tenant shall furnish all branch piping and expense. requirements. All piping shall be threaded schedule 40 black steel meeting ASTM A135. All pipefitting are sprinklers required to complete the sprinkler system within the Tenant Space. required to be pressure class 175. TENANT WORK : GENERAL RQUIREMENTS 6. All hangers are to be of an approved type and Tenant’s sprinkler system design shall be based upon a single source of supply, ordinary hazard pipe Tenant shall engage in the services of a Landlord spaced in accordance with NFPA#13. Seismic bracing schedule system as outlined in NFPA pamphlet #13 approved sprinkler contractor. A contact may be to be installed per U.B.C. and Landlord’s insurance carrier’s requirements. obtained from Tenant Coordination. 7. Tenant shall furnish and install a vane-type water flow Hydraulically calculated sprinkler systems are required. • Schedule 10 with mechanical cut grove type pipe couplings and fittings. 1. Tenant sprinkler system shall be connected to the detector in the main sprinkler line immediately after Mall mains. Tenant shall attach a tamper switch and connection to Landlord’s main. A flow detector shall interface with the Mall’s fire alarm system. be installed, per the manufacturer’s instructions and shall be designed to detect any water flow that equals • Group II Occupancy with a sprinkler density of 0.16/3000 square feet in the retail area and 2. All sprinkler heads shall be quick response type, or exceeds 10 g.p.m. Detector switch mechanism shall 0.18/3000 square feet in stock areas. semi-concealed or fully concealed (the same brand incorporate an instantly recycling mechanical retard and type as installed by Landlord in the mall common element with an adjustable range of 0-60 seconds. areas), UL listed, Factory Mutual approved. Sprinklers The Detector Enclosure shall be dust tight, the Switch at the Tenant demising wall must be concealed type, Enclosure shall be tamper proof and the Flow Switch LANDLORD WORK spaced six (6’) feet on center. shall be connected to Mall fire alarm system. Sizing of the service main or capped branch connection 3. Tenants sprinkler system must include a water 8. is based on one sprinkler head per one hundred (100) curtain within Tenants Demised Premises along the extinguishers in stock room areas and elsewhere square feet of floor area of the Demised Premises. Mall lease line and/or storefront. throughout the Demised Premises, as required by all • All systems shall be designed to high protection risk (H.P.R.) requirements. Tenant Retail Criteria Manual | 67 shall provide appropriate-type fire 5.0 ENGINEERING Fire Suppression Design local authorities having jurisdiction and Landlord’s FOOD COURT / SERVICE : ADDITIONAL S P R I N K L E R S H O P D R AW I N G insurance carrier. Fire extinguishers shall be furnished, REQUIREMENT S U B M I T TA L As a matter of routine practice, fire extinguishers shall All walk in coolers / freezers shall be supplied with 1. The Tenant’s sprinkler contractor shall submit one be serviced and inspected monthly. non-freezing sprinklers of the same brand and type as (1) vellum and one (1) blueline print of the sprinkler installed by Landlord in mall common areas. shop drawings to the Tenant Design Coordinator for as directed by the Fire Marshal and be easily accessible. review and approval. Sprinkler system shop drawings 9. All materials and equipment under this section shall be new and listed by Underwriters Laboratories, Tenant demised Premises with exhaust hoods, must be approved by the local authorities having the Inc. and Factory Mutual for fire protection system grilles, and/or cooking facilities must provide a fire proper jurisdiction prior to the installation. Sprinkler installation and approved by all authorities having extinguishing system, including an alarm system. system must comply with all applicable sections of the jurisdiction and governing codes. Provide specific details of this installation on the NFPA#96 pamphlet. sprinkler plans or as required of the Fire Department 10. Final connection to Landlord’s sprinkler main Regulations. Upon activation of this system all cooking 2. Landlord’s Tenant Coordinator shall distribute shall not be made until the entire system within the equipment must shut down automatically. Landlord-approved sprinkler shop drawings to the following: Demised Premises is pressure-tested and ready for D R AW I N G R E Q U I R E M E N T S service. • Sprinkler Contractor (3 copies); 11. Tenant shall not be allowed to stock the Tenant Tenant’s sprinkler drawings shall include, but not be • Landlord’s insurance carrier (2 copies); Space until the entire sprinkler system has been limited to, the following: • Shopping town Manager (1 copy) and; • Tenant Construction Coordinator (2 copies). inspected, approved and put into operation. All sprinkler system tests shall be witnessed by Landlord’s on-site representative and local jurisdictional authorities, as required. 12. The entire installation shall be performed by a licensed sprinkler contractor in a first-class, workmanlike manner. • With final plan submission, a reflected ceiling plan at one-quarter inch (¼”) scale or larger, including 3. Landlord’s insurance carrier shall review the plans all sprinkler locations, pipe size and locations. and forward their comments to Landlord’s Tenant • Specifications, including all details, materials and Coordinator, who shall then forward the comments to equipment. • Sprinkler shop drawings, as prepared by Tenant’s sprinkler contractor, sealed by a California Professional Engineer 68 | Westfield Oakridge the sprinkler contractor. Tenant’s sprinkler contractor shall implement any modifications as part of Tenant work. 6.0 TENANT SUBMISSION PROCESS Retail Criteria Manual | 69 6.0 TENANT SUBMISSION PROCESS Phase I : Preliminary Drawings The Tenant, at the Tenant’s expense, must select an architect to prepare complete plans and specifications for the D R AW I N G S U B M I S S I O N S improvements to the premises. The Tenant and the Tenant’s architect may be subject to certain contracting, first source referral, hiring and job training programs. The Tenant must contact coordinator for specific requirements. Please refer to the first section under “Store Construction” of this handbook for additional information. Plans must be submitted to Landlord for approval in three phases: Preliminary Design Documents, Tenants needing assistance in locating an experienced, locally licensed architect should contact the Tenant Construction Documents and Sign Shop Drawings. Coordination Administrator. The Tenant must forward a copy of this Handbook along with a print of the Tenant These phases are detailed in this Section. Lease Plan, Design Control Drawings and associated details to their architect. It is the Tenant’s and Tenant’s architect’s responsibility to obtain, review, and comply with all applicable codes and criteria contained herein. The Tenant shall notify the Tenant Coordinator of the architect’s name, address, email and telephone number within 10 days of Lease execution or receipt of Tenant Lease Plan Package. All drawings must be signed and sealed by an architect registered in the State of California. All drawing submittals shall be in full size (42”x30”) Adobe PDF format. All drawings shall be submitted electronically at www. westfieldtenantcoordination.com. Please contact Westfield Tenant Services Administrator or TSA for After receiving the Exhibit A2 or Lease Outline Drawing (L.O.D), carefully reviewing the design criteria and project specific login information. applicable codes, and field verifying the space conforms with the Exhibit A2 or Lease Outline Drawing (L.O.D), the Tenant’s architect (in conjunction with the Tenant) shall proceed with the preliminary design of the Tenant’s Tenants are required to submit, for final Landlord approval, one color rendered Storefront Elevation premises. correctly illustrating the Tenant’s colors and finishes. It is the responsibility of the Tenant and Tenant’s architect to schedule adequate time for Landlord’s This shall be in the form of PDF, JPEG or comparable preliminary review, Tenant’s subsequent revisions if required, final construction drawings and Landlord’s final image file. review. Tenants must submit a physical color sample board which shall be mailed to the Landlord’s Tenant Coordination Office. 70 | Westfield Oakridge 6.0 TENANT SUBMISSION PROCESS Phase I : Preliminary Drawings P H A S E I : P R E L I M I N A R Y D R AW I N G S If Tenant’s Storefront design follows a specific prototype, photographs of existing stores should be The purpose of this phase is to acquaint the Landlord with the Tenant’s design intent so that the Landlord • Submit a color rendered elevation of the storefront. submitted to aid the Tenant Coordinator in the review process. • Sketches, perspectives, sections or other details may comment and/or advise Tenant of any changes Drawings must include the following information as a necessary to meet the criteria prior to commencing minimum: that will clarify the design of the Storefront. • Material finish and color sample board(s), properly the working drawing phase. mounted and labeled. Photos of materials will not As soon as the preliminary design has been completed and approved by the Tenant and, before proceeding • Minimum drawing size shall be 30” x 42”, FULL SIZE be accepted. PDF BOOK. with final working drawings, Tenant’s architect shall submit the preliminary design to the Tenant • The Tenant Coordinator will review the preliminary • Preliminary floor plans (scale 1/4”=1’-0”) indicating design and make necessary corrections or interior design concept, approximate location of suggestions and return, with comments and/ The preliminary design shall be submitted within 20 fixtures and equipment, interior partitions, toilet or approval, one marked-up set of prints to the days after the Lease is executed or receipt of the Tenant rooms, exits, etc., identifying all materials& colors. Tenant and Tenant’s architect. Coordinator for review and approval. Lease Plan Package. Drawings shall clearly identify on a key plan the Project name, Tenant’s store name, and space number. • Reflected ceiling plan (scale: 1/4”=1’-0”) ndicating all soffits, ceiling heights, materials, lighting layouts, and location of HVAC diffusers. • Typical interior transverse and longitudinal sections (scale: 1/4” = 1’-0”) indicating interior elevations. • Storefront elevation (scale: 3/8”=1’-0” minimum) and section (scale: 3/4”=1’-0” minimum), including any graphics and signage. Indicate all materials and finishes. Retail Criteria Manual | 71 6.0 TENANT SUBMISSION PROCESS Phase II : Final Drawings R E S P O N S I B I L I T Y M AT R I X P H A S E I I : F I N A L D R AW I N G S Landlord’s designated contractor at Tenant’s expense Items listed in this manner shall be provided by the After the preliminary drawings have been approved, Tenant’s architect shall proceed with the final LANDLORD AT LANDLORD’S EXPENSE Landlord’s Designated Contractors, at the Tenant’s expense, in order to either maintain complete control Items listed in this manner shall be provided by the over quality and workmanship of critical installations Landlord, at the Landlord’s expense, in accordance with for work which can best be performed and coordinated the Landlord’s plans and specifications and constitutes by a single contractor; or where uniformity of material, the Landlord’s complete responsibility with regard color and workmanship of finished surfaces is Tenant shall submit final Construction Documents to the construction of the Lease space. All items not required. within 21 days of receipt of Landlord’s approval of listed in this manner, which are required to complete preliminary drawings. Tenant shall submit the final the premises in accordance with Tenant’s plans and Construction Documents to the Tenant Coordinator. All specifications, shall be performed at the Tenant’s sole drawings and specifications must be clearly identified cost and expense (subject to the conditions imposed with the Project name, the Tenant’s store name, the by the Landlord). Construction Documents and specifications. These drawings shall incorporate the design suggestions and comments of the Tenant Coordinator. Tenant space number, and the name and seal of the architect or engineer preparing these drawings This work must be contracted directly with the Landlord designated contractor, by the Tenant, at Tenant’s expense. Landlord shall competitively bid all parts of construction that require Tenant use of Landlord LANDLORD AT TENANT’S EXPENSE designated contractor, to assure the best, lowest price. indicating that he or she is registered with the State of California. Items listed in this manner will be provided by the Landlord, at the Tenant’s expense, in order to Tenants are required to submit a color rendered either maintain complete control over quality and elevation of the storefront in the final submittal workmanship of critical installations for work which package. Re-submittal of rendering with finals package can best be performed and coordinated by a single can be waived if no significant changes were made to contractor; or where uniformity of material, color and façade. workmanship of finished surfaces is required. If for any reason Tenant fails to pay amounts due to the Landlord’s Designated Contractor, then such amounts along with accrued interest charges will be considered rent due and payable pursuant to the Lease or deducted from Tenant’s allowance. Tenant at Tenant’s expense Items of construction and expenses not specifically Final working drawings and specifications shall consist If for any reason the Tenant fails to pay amounts due listed in the prior sections which are required to of a minimum of the following: the Landlord hereunder, then such amounts, along complete the Tenant’s premises in accordance with the with accrued interest charges, will be considered to be Landlord criteria shall be the Tenant’s responsibility and Drawings must include the following information as a additional rent due and payable pursuant to the Lease, shall be provided by the Tenant at Tenant’s expense. minimum: or deducted from the Tenant Allowance. 72 | Westfield Oakridge 6.0 TENANT SUBMISSION PROCESS Phase II : Final Drawings ARCHITECTURAL PLANS N E C E S S A R Y S E C T I O N S A N D D E TA I L S REFLECTED CEILING PLAN (SCALE: 1/4” = 1’-0”) • Longitudinal and transverse sections through store Drawings must contain the following information: • Ceiling heights including drops and soffits. Detailed Plot Plan, including: building footprint • Types of ceiling construction. site plan, Tenant address, name of business, type of • Decor at ceiling. building construction, and if sprinklered. • Location of lighting fixtures, sprinkler heads, air • Occupancy load. • Large scale section through storefront from floor to rough ceiling (SCALE: 3/4”=1’-0”). • Compliance with California Disabled Access Regulations and Title 24. • An approved ADA path of travel should be incorporated in each Tenant’s improvement package. ceiling (SCALE: 1-l/2”=1’-0”). S T O R E F R O N T E L E VAT I O N S • Wall sections and details. (SCALE: 3/8” = 1’-0” minimum) and • Dimensioned Slab Penetration Plans. SCHEDULES I N T E R I O R E L E VAT I O N S • Door and hardware schedules/details. (SCALE: 1/4”=1’-0”) • Color storefront elevation and submit photograph FLOOR PLAN (SCALE: 1/4” = 1’-0”) • Demising wall locations and dimensions. • Dimensioned interior partitions. • Existing and proposed walls. • Rest room facilities. • Door locations, sizes, direction of swing. • Store closure details. • Details at neutral piers and Landlord’s bulkhead at diffusers, grilles, and access panels. • Construction type classification. • Use or occupancy classification. from slab to rough ceiling (SCALE: 1/4”=1’-0”). • Room finish schedule. of similar existing stores. • Finishes and colors. • Signage. • Menu boards for Food Tenants. • Toilet room interior elevations locating all toilet room accessories indicating ADA compliant mounting heights. • Location of fixtures and equipment. • Floor Plans are required to have details showing that rest room facilities, public telephones, drinking fountains, door hardware, handrails, stairs, and point of sale locations are in compliance with Title24 California Administrative Code. Retail Criteria Manual | 73 6.0 TENANT SUBMISSION PROCESS Phase II : Final Drawings PLUMBING PLANS H E AT I N G , V E N T I L AT I N G & EXHAUST SYSTEMS AIR CONDITIONING PLANS • Specifications of exhaust equipment The plumbing drawings shall incorporate all minimum The HVAC drawings shall incorporate all minimum • Location of equipment (including front and side design and construction requirements. design and construction requirements, including complete calculations indicating heat gain to and heat PLUMBING PLAN loss from the space for all lights, occupancy, exterior (SCALE: 1/4” = 1’-0”) exposure (if any) and other heat producing elements. • Toilet facilities elevations) • Methods of installation S C H E D U L E S A N D D E TA I L S • Diffuser and Grille Schedule • Location of all plumbing fixtures H VAC P L A N • Location of sewer connection • Equipment schedule (SCALE: 1/4” = 1’-0”) • Toilet exhaust duct connection detail • Location of plumbing vent connection • Location and size of HVAC equipment • Location of clean-outs and floor drains • Title 24 Energy Conservation Calculations • Ductwork layout and sizes • Domestic water distribution system • Ductwork material schedule • Water meter location N E C E S S A R Y I S O M E T R I C S A N D D E TA I L S • DS-3 Heat Gain Calculations • Damper locations • DS-4 Air Handling Schedule • Combination fire/smoke dampers at penetrations • DS-5 Heat Gain Calculations through fire-rated construction • Sanitary system isometric T E N A N T TO S U B M I T W I T H F I N A L D R AW I N G S : • Height above finished floor • DS-6 Heat Loss Calculations • Domestic water isometric • Type of insulation • DS-7 Air Handling Unit Schedule • Water heater detail with relief valve and piping • Location of diffusers, grilles and registers • DS-7A Electric Heater Schedule • Detail of connection to Landlord’s systems • Thermostat location • DS-8 Duct Static Pressure Calculations • Piping details for air handling units • Return Air Path • DS-9 Exhaust Gas Equipment Schedules • Title 24 Energy Conservation Calculations • Ductwork • DS-10 Plumbing/Pump/Domestic Water Heater • Transfer Openings • Schedules • Air Handling Unit mixing box detail 74 | Westfield Oakridge 6.0 TENANT SUBMISSION PROCESS Phase II : Final Drawings ELECTRICAL PLANS SCHEDULES ELECTRICAL PLAN (SCALE: 1/4” = 1’0”) • Lighting Fixture Schedule Minimum design and construction requirements • Location of all floor and wall outlets including complete calculations and show the total • Location of main service panels simultaneous load maintained at three hours or • Location of connections, • Electrical disconnects controllers for toilet exhaust and other fans, motors and all HVAC equipment lighting (including emergency and night lighting), sign lighting, receptacles, toilet exhaust and other fans and • Location of all transformers, electrical and phone 277/480V M I S C E L L A N E O U S D E TA I L S • Electrical Distribution Riser Diagram • Feeder conduit and wire size panels • All loads assigned to circuits including an itemized • Arrangement of panels, transformer, time clock, disconnects, meter, etc. load break down • Indicate telephone and conduit locations service to HVAC and supplementary equipment. Show single line power riser diagram indicating main for and miscellaneous loads per square foot. and transformation for voltages, all circuits for store Schedules or 120/208V. more for the store area and all other light, HVAC, and Electrical drawings and specifications shall show power Panel T E N A N T TO S U B M I T W I T H F I N A L D R AW I N G S : disconnects, size of wire, conduit, panels, trans-formers, • DS-1 Electrical Equipment Load Breakdown time clock, etc. Show panel schedule and itemized • DS-2 Electrical Equipment Load Breakdown • Conduit and wire size to HVAC equipment and panels as applicable • Title 24 Energy Conservation Calculations and controls compliance statement load breakdown in connected kilowatts for the premises including lighting, receptacles, sign lighting, LIGHTING PLAN water heating, special appliances, toilet exhaust fans, (SCALE: 1/4” = 1’-0”) • Provide Electrical load calculations showing loads less than 15 watts/sf connected load allowance. make-up air fan, miscellaneous space heating, sales • Lighting fixture layout including night and sign door operator motor, fan coil unit, return air fans, air • Lighting curtains, heat pumps, and large motors, etc… • Emergency and exit light locations • All lighting assigned to circuits • Indicate sign and lights which are connected to time clock • Emergency lighting and connection to Landlord provided Circuit • Fire Alarm Plan • Location of all devices • Logic and sequencing • Load calculations and voltage drop Retail Criteria Manual | 75 6.0 TENANT SUBMISSION PROCESS Phase II : Final Drawings In the Tenant’s storage areas, fully exposed or semi- FIRE PROTEC TION PLANS F I N A L D R AW I N G A P P R O VA L recessed heads can be used. Sprinkler heads must These plans must be submitted for approval in order to be of the fully recessed type. All heads shall be It must be understood that the Landlord’s approval verify compliance in accordance with the requirements quick response. Tenant shall submit three sets and of the construction documents is for compliance with of Landlord’s insurance carrier. Show on the reflected calculations for review and approval to Landlord’s the criteria established in this Handbook only. By ceiling plan the sprinkler lay out, clearly identifying all insurance underwriter. reviewing these drawings, the Landlord, its agent(s) heads as required. Plan submittal shall comply with NRPA13 requirements and shall include, but not be and consultant(s) assume no responsibility for code It is the Tenant’s sprinkler contractor’s responsibility to comply with Landlord’s insurance underwriter’s limited to: requirements. • Location of existing sprinkler grid with main and compliance (including ADA requirements), dimensional accuracy, engineering accuracy or completeness of these drawings for construction purpose. It is the Tenant’s sole responsibility to comply with all laws, codes, and regulations as may apply. branch pipe sizes • Location of heads and branch piping. The Tenant Coordinator reserves the right to request • Heights of ceilings and dropped soffits, etc. • Location of smoke detectors, file alarm speakers additional detailed shop drawings for review after final working drawings have been approved. and strobe lights • Location of surface mounted or dropped lighting and decorative beams Upon receipt of complete sets of drawings and specifications as outlined above, the Landlord will • Location and height of walls or lighting baffles review these drawings for compliance with the • Hydraulic information used for design of system previously approved preliminary design and other • Other construction which will affect sprinklers criteria of this Handbook, and return one set of prints to • Cross section the Tenant and the Tenant’s architect. Simultaneously, one set of approved drawings is forwarded to the Landlord Tenant Construction Superintendent for field coordination during construction. It is the Tenant’s responsibility to see that the approved sets of drawings with comments, if any, are distributed to its contractor and in-house construction staff. 76 | Westfield Oakridge 6.0 TENANT SUBMISSION PROCESS Phase III : Signage Drawings P H A S E I I I : S I G N A G E D R AW I N G P H A S E S I G N A G E A N D E N V I R O N M E N TA L G R A P H I C S S H O P D R AW I N G S U B M I T TA L Tenant shall submit one (1) set of PDF formatted copy of the proposed signage during the preliminary phase, showing location, color, materials and attachment devices. Upon approval, Tenant shall furnish Landlord with one (1) set of PDF formatted copy of shop drawings, including color and materials samples prior to fabrication. Shop drawings for signage and/or menu boards shall include the following criteria: S I G N AG E S H O P D R AW I N G S (SCALE: 1/2” = 1’-0” or larger) • Elevation of main identity • Plan of signage • Section through signage • Detail of all attachments • Proposed graphics, photos and/or colors, including all materials in .PDF or similar format Retail Criteria Manual | 77 6.0 TENANT SUBMISSION PROCESS Phase IV : Completion Requirement Upon completion of the Tenant work, Tenant shall PHASE IV: COMPLETION REQUIREMENTS D E FA U LT R E S U B M I T TA L S If Tenant fails to adequately perform any of the • Tenant’s final notarized original affidavit that following items, Landlord may, at any time thereafter, Tenant’s work has been completed to Tenant’s In event that any drawing submittal requires revisions give Tenant notice that Tenant is in default of its Lease. satisfaction and in strict accordance with the Final and a resubmittal, Tenant shall, within 10 calendar Such notice will describe the nature of the Tenant’s Working Drawings and Tenant’s and Landlord’s days, revise and resubmit to Landlord. Once Tenant default and will specify a date after the giving of construction requirements. Such affidavit may be drawings are approved, no changes shall be made such notice by which such default must be cured. relied on by Landlord. Any deliberate or negligent unless approved by Landlord in writing. Unless prior to such date Tenant makes the required misstatement or false statement made by Tenant submissions, Tenant will be deemed incurably in therein shall constitute breach of the Lease. deliver to Landlord the following: default of this Lease and Landlord will be entitled to all remedies specified in the Lease: • The final notarized original affidavit and waiver of • Submit to Landlord preliminary plans and final working drawings and specifications. • Submit to Landlord final approved sprinkler shop and fire alarm drawings and specifications. lien by the General Contractor performing Tenant’s work to the effect that Tenant work was completed in accordance with the Landlordapproved working drawings. Affidavit shall also state that all sub-contractors, laborers, material suppliers engaged in furnishing materials and/ • Present a full set of final working drawings approved by the Landlord and endorsed with the or rendering services for Tenant work, have been paid in full. approval stamp and permit number of the Building Department to On-site Tenant Coordinator, before commencement of construction. • Complete operating, maintenance and spare parts manuals for all mechanical, electrical and similar equipment installed as part of Tenant work. • Cause Tenant’s space to be built strictly in accordance with the final set of Landlord’s approved plans. • Tenant shall commence Tenant work promptly after Landlord’s approval of the Final Working Drawings. • Items above shall be forwarded to: Westfield, LLC Tenant Coordination 11601 Wilshire Blvd., 11th Floor Los Angeles, CA 90025 Tel: 310.478.4456 Fax: 310.575.5991 78 | Westfield Oakridge 7.0 STORE CONSTRUCTION Retail Criteria Manual | 79 7.0 STORE CONS TRUC TION INTRODUCTION A pre-construction meeting must be held with the Tenant’s Contractor must pay all required fees, On-site Tenant Coordinator to determine suitable including, but not limited to, security deposit, trash Contractors and subcontractors shall not discriminate access routes to the site and the premises, designated removal fee, vertical transportation fee, and temporary against any person or group of persons on account of loading, unloading and storage areas for materials, use utility fees, to the On-site Tenant Coordinator. Security race, sex, marital status, age, handicaps, color, creed, of vertical transportation, working hours, tap-ins to deposit shall not be released until issuance of the religion, national origin or ancestry. All contractors utility lines, safety precautions and procedures, rubbish Tenant’s Certificate of Occupancy and completion of shall have good labor relations, be capable of removal and location of Tenant’s trash receptacles, the Landlord’s punch list, and final lien release have performing quality workmanship and work in harmony scheduling of Tenant’s construction, temporary utilities been secured. with Landlord’s contractors and other contractors on and many other requirements of the On-site Tenant the job, and any other labor entity at or servicing the Coordinator. Coordinator a subcontractor list of all the subs that will center. Tenant’s contractor shall cooperate with the Onsite Tenant Coordinator and any other contractor by coordinating its work in order not to interfere with the operations of existing stores, or impede or endanger the safety of the public. The contractor must submit to On-site Tenant The Contractor must obtain from, and review with the be working on the project. On-site Tenant Coordinator On-site Tenant Coordinator, the Tenant Contractors’ shall verify that the Notice of Non-Responsibility Construction Guidelines and Project Safety and Health has been posted and has been filed with the County Procedures Manual containing the Project’s rules and Records. regulations with which the Tenant’s contractor must The Tenant’s Contractor shall require each of its comply. The Tenant’s Contractor must verify on-site dimensions and existing conditions of the demised premises subcontractors, to the extent of the work to be performed by the subcontractors, to be bound to Final working drawings and specifications must have before Tenant’s Contractor will be permitted to start the terms and conditions of the agreement between been approved for construction by the Landlord’s construction, the contractor must comply with certain the Landlord and Tenant, and to the Tenant Criteria Tenant Coordinator. The Tenant’s Contractor must prerequisites. Tenants and Tenant’s Contractors must Manual. verify with On-site Tenant Coordinator that the contract understand the complexity of the logistics of building documents incorporate all of the Tenant Coordinator’s in such constrained site. comments. PREREQUISITE TO TENANT CONSTRUCTION Building permit(s) must be obtained and a copy of same submitted to On-site Tenant Coordinator. The Before Tenant’s Contractor will be permitted to start PERMITS original(s) must be posted at the job site. construction, the contractor must comply with certain The Tenant, or the Tenant’s Contractor, must submit the prerequisites. Tenants and Tenant’s Contractors must Certificates of current, in-force insurance for the required number of sets of final working drawings and understand the complexity of the logistics of building minimum requirements as specified by the Landlord specifications, apply for a building permit and pay all in such constrained site. must be filed with On-site Tenant Coordinator. associated fees. All permits and one set of approved 80 | Westfield Oakridge 7.0 STORE CONS TRUC TION drawings must be kept at the construction site during in the amount of $1,000,000 combined single limit. construction. Consult the building department for the Worker’s compensation with statutory requirements, required number of signed and stamped drawings including employer’s liability of $1,000,000 must also Access to the demised premises will be restricted to to be submitted. Building Department and Fire be carried. only those employees working on the project. No Department fees are collected at the time of submittal and upon issuance of the permit. These fees are based on the cost of Tenant’s construction. All insurance policies shall name the Landlord and its subsidiaries as additional insured, as their interest may appear. Landlord will provide names in the The Building Official will coordinate the review of the reconstruction meeting. CONTRAC TORS / VENDORS ACCESS children are allowed on the project site during the construction period. At no time are pets allowed on the project site. Access to the Project and Tenant spaces during off- Tenant’s prints and specifications. The Building Official hours must be coordinated through the Landlord’s on will forward the prints and specifications to the Fire Certificates of insurance shall provide that no change site representative and Mall Security; any additional Marshal’s office for their review and approval, before a or cancellation of such insurance will be undertaken costs associated with off-hours work shall be borne by permit can be issued. Tenant’s licensed sign contractor without thirty days written notice to Landlord. the Tenant. shall also submit sign shop drawings to the Building Certificates of current in-force insurance must be Department in order to obtain a sign permit. filed with the On-site Tenant Coordinator before the commencement of construction. Renewal certificates INSURANCE must be submitted ten days prior to the expiration of existing coverage. Insurance must remain in force for The Tenant’s General Contractor shall carry and be distributed by the Landlord’s on site representative at the Pre-construction meeting. Parking is not allowed Contractor/ Vendors/ Tenants shall comply with the traffic control and parking requirements of the Project. BOND The Landlord reserves its right to tow any vehicle requirements for comprehensive general liability: $3,000,000 per person per occurrence, $3,000,000 Any contractor engaged by Tenant having a contract per occurrence for bodily injury, and $2,000,000 for of fifty thousand dollars or more shall furnish a property damage per occurrence. This insurance performance bond naming both the Tenant and the must be endorsed to show products and completed Landlord as additional obligees, as their interest may operations coverage including Waiver of X, C, and U appear. Evidence of the bond must be filed with the exclusions, broad form property damage. Tenant’s On-site Tenant Coordinator before construction may General Contractor shall also carry automobile liability begin. insurance covering bodily injury and property damage project. A map denoting approved parking areas shall along the curb at the building or in the truck dock. All one year after completion of the work. maintain at its sole cost and expense construction insurance in accordance with the following minimum Parking is only permitted in designated areas of the parked in violation of posted parking procedures at the Tenant’s and/or General Contractor’s sole cost and expense. SECURITY / SAFETY Neither Westfield, the Landlord nor their General Contractor shall be responsible for security in the Retail Criteria Manual | 81 7.0 STORE CONS TRUC TION Tenant spaces and will not be responsible for loss or fire extinguisher within the Tenant space throughout damage to any materials, tools or equipment. Any construction. security required above and beyond that provided by the Landlord shall be at the sole cost of the Tenant’s Contractor/Vendor/Tenant. Additional Tenant security The Landlord’s has initiated a “no smoking” policy with the building at all times. The Tenant’s Contractor is requested to use caution in Tenant Coordinator. stocking materials and equipment on the Upper Levels as to not overload the structure. to modify, attach to or hang any loads from the conduit or bridging. Access to building roof is restricted to Landlord’s personnel and Landlord’s Designated Contractors. No and healthful place of employment for all employees, and to abide by all applicable regulations as they The Tenant’s Contractor shall not be permitted Landlord’s ductwork, water lines, sprinkler lines, arrangements must be coordinated with the On-site It is the safety policy of the Landlord, to provide a safe LANDLORD’S PRIOR RIGHTS CONSTRUCTION SCHEDULE Tenant Contractor or Subcontractor will be permitted on the roof. apply to this project. Therefore, without exception, Landlord has adopted as the Project’s safety program, The Tenant’s Contractor shall promptly submit The penetration of the roof deck and the installation of all the State of California safety rules and the entire to the On-site Tenant Coordinator a construction all flashing and curbing for Tenant related equipment Occupational Safety and Health, Safety Standards Part schedule showing the work schedule and anticipated shall be by Landlord’s designated roofing contractor at 1926, and any amendments thereto as the safety rules completion of the store. Tenant’s expense. When necessary, it will be the Tenant’s Contractor’s Tenant shall use Landlord’s Authorized Contractor for responsibility to make arrangements for access into fire alarm to the mall’s main system. that must be followed by all persons and/or companies employed on the project. Proper work clothing, and shoes must be worn on site. adjacent occupied Tenant spaces and to protect No gasoline powered equipment such as welders, that Tenant’s finishes and merchandise as required. compressors, concrete saws, power buggies, etc. will The Tenant’s Contractor shall be responsible for any be allowed to be used in the Atrium or Tenant spaces. damage or loss as a result of their operations. No flammable materials are to be stored inside Any work on the mall’s common side of the Storefront, the building except those materials which will be once the barricade has been removed, must be consumed during that work day. scheduled with the Landlord’s Superintendent and may The playing of radios, CD and tape players, etc., will not be allowed. The Tenant Contractor shall maintain a fully charged Tenant’s Contractor shall not deviate from approved drawings and specifications without obtaining prior written permission from Tenant, Landlord’s Tenant Coordinator, and the Building Department and/or other governmental agency. C H A N G E S I N D E S I G N O R M AT E R I A L only be allowed during off-hours. During such work, the mall’s flooring and finishes must be protected with The Landlord will furnish the standard mall flooring 1/2” plywood and the area cleaned after each work material at Tenant’s expense to the Tenant’s Contractor. period. The Tenant’s Contractor shall be responsible for the 82 | Westfield Oakridge 7.0 STORE CONS TRUC TION installation of the finish flooring up to the Tenant’s CLEAN-UP demolition and removal at Tenant’s expense. Storefront and closure line. Tenant Contractor shall The mall, public corridors, service corridors, and purchase mall finish flooring for this purpose from the Tenant’s Contractor shall pay a fee at the pre- Landlord. construction meeting for the use of the Project’s trash All mall finishes and adjacent Tenant spaces must be protected from damage and dirt. It is the Tenant’s responsibility to repair all existing Landlord or adjacent Tenant construction finishes which may have become damaged as a result of Tenant’s construction. facilities. equipment, merchandise, fixtures, refuse and trash at all times. All Contractors/Vendors/Tenants are responsible for clean-up and trash removal from their work areas on a daily basis. Storage of debris in Tenant spaces or mall areas will not be allowed. Non-compliance will result in clean-up by others with all associated costs charged to the non-complaint party. The Landlord will provide ADJACENT FINISHES adjacent Tenant spaces must be kept clear of Tenant’s Landlord’s designated construction trash containers may not be used for disposal of Tenant’s boxes, wrappings, paper and other containers originating from fixturing and/or merchandising after completion of construction. Landlord shall provide a separate trash container for this purpose at Tenant’s expense. containers at loading docks or designated area. Landlord will empty the containers. All Contractors/ I N S P E C T I O N A N D A C C E P TA N C E Vendors/Tenants will be responsible for cleaning and The Landlord will furnish the standard mall flooring transporting their own debris from the work areas to material at Tenant’s expense to the Tenant’s Contractor. the container through designated service corridors The Tenant’s Contractor shall be responsible for the and elevators, as well as sorting construction debris installation of the finish flooring up to the Tenant’s from raw cardboard. Any trash or construction debris Storefront and closure line. Tenant Contractor shall considered to be hazardous or environmentally purchase mall finish flooring for this purpose from the dangerous materials will not be allowed to be placed Landlord. in the containers. Contractors/Vendors/Tenants will All mall finishes and adjacent Tenant spaces must be protected from damage and dirt. It is the Tenant’s responsibility to repair all existing Landlord or adjacent Tenant construction finishes which may have become damaged as a result of Tenant’s construction. not be allowed to provide their own dumpster on site. It is the Tenant’s Contractor’s responsibility to schedule inspections by the appropriate Department of Building Inspection, Fire Department and other inspectors as necessary, and to comply with their requirements, and all codes and regulations. A copy of all inspection reports must be submitted to the On-site Tenant Coordinator. Inspections should be scheduled so that there is adequate time to make any changes required Upon completion of the Tenant’s construction and, by the inspectors prior to the store opening. with the approval of On-site Tenant Coordinator, the Tenant shall promptly dismantle, remove and dispose of the temporary Tenant enclosure and any excess materials from the premises. Should the Tenant fail to comply with the above, the Landlord may proceed, No Tenant will be allowed to open for business without first obtaining approval from the Building Department, Plumbing, Electrical, Fire Department, and On-site Tenant Coordinator. upon 24-hour notice, with the necessary clean-up, Retail Criteria Manual | 83 7.0 STORE CONS TRUC TION From time to time, and upon completion, C E R T I F I C AT E O F O C C U PA N C Y Landlord’s Tenant Coordinator will inspect Tenant’s The construction of the Tenant’s premises is to be performed in accordance with the Tenant’s construction for compliance with approved drawings Tenant shall obtain a Certificate of Occupancy from and approved the Building Department and submit a copy of this corrected, needing assistance in locating experienced local certificate to Landlord’s On-site Tenant Coordinator regardless of their acceptance by public authority or general contractors should contact the Tenant before opening the premises to the public. The original the Tenant. Coordinator for assistance. All general contractors must be posted within the Tenant space. as well as all subcontractors, including, but not specifications. workmanship must Deviations be or unsatisfactory immediately WA I V E R S O F L I E N Remedial work must be completed by the date provided or the work will be completed by the Landlord at the Tenant’s expense. gas piping, electrical and sign contractors must be In making progress and final payments to contractors, local business license. The Tenant must forward a Tenant should obtain valid Final Waivers of Lien, copy of this Handbook to their general contractor. indicating payment in full for labor, materials, and subcontractors. Landlord may request to see evidence of such Waivers before permitting Tenant to open the premises for business. All payment and liens must be V I O L AT I O N S specifications. Tenants licensed by the State of California, and possess a site Tenant Coordinator will inspect the construction and issue a punch list if remedial action is required. and limited to heating and air conditioning, plumbing, Tenant Contractor shall notify the On-site Tenant Coordinator upon completion of the space. The On- plans resolved prior to release of full Tenant Allowance. In the event the Tenant is notified of any violation of codes, ordinances, or regulations, or of its obligations hereunder, either by the jurisdictional authorities or by Landlord, Tenant shall correct such violations and pay corresponding fines within three calendar days, or Landlord will correct, at Tenant’s expense, such violations at Landlord’s actual cost plus fifteen percent cost for administration. Failure to comply with Landlord rules and regulations will be grounds for additional fines. 84 | Westfield Oakridge The General Contractor selected by the Tenant must employ a competent, full-time superintendent on site at all times during construction and must observe suitable safety practices. 8.0 GENERAL INFORMATION Retail Criteria Manual | 85 8.0 GENER AL INFORMATION Landlord’s Staff/Government Agencies B A S E B U I L D I N G I N F O R M AT I O N L A N D L O A D ’ S C O O R D I N AT I N G S TA F F GOVERNMENT AGENCIES CO N S T R U C T I O N T Y P E : Our coordinating staff will provide a liaison service B U I L D I N G D E PA R T M E N T between the Landlord, the Tenant, the Tenant’s City of San Jose • Existing mall building: V-N fully sprinklered Architect and/or Designer and the General Contractor. Planning, Building and Code Enforcement • New expansion building:ll F.R. and ll-N fully These individuals are available to assist you. 200 East Santa Clara Street sprinklered San Jose, CA 951103-1905 O CC U PA N C Y T Y P E : LANDLORD Phone: 408-535-3555 Westfield, LLC. Fax: 408-292-6055 11601 Wilshire Blvd., 11th Floor Website: www.sanjoseca.gov/planing Los Angeles, CA 90025 • Primary occupancy: Group M (Merchantile) • Food Court: Group A2.1 (Assembly 50 - <300 H E A LT H D E PA R T M E N T LEASING Department of Public Health Westfield, LLC . 2200 Moorpark Avenue 11601 Wilshire Blvd., 11th Floor San Jose, CA 95128 • Kitchen: Group F-1 Los Angeles, CA 90025 Phone: 408-299-6060 • Office: Group B Phone: 310-478-4456 persons, without storage) • Restaurant: GroupA3 (Assembly >300 persons, without a stage) • Storage: Group S-1 FIRE MARSHALL TENANT COORDINATION Bureau of Fire Protection Westfield LLC. 200 East Santa Clara Street, Tower 2 11601 Wilshire Blvd., 11th Floor San Jose, CA 95113 Los Angeles, CA 90025 Phone: 408-535-7750 Phone: 310-478-4456 Fax: 408-292-6067 Fax: 310-575-5991 Website: sjfd.org MALL MANAGEMENT Westfield Oakridge 925 Blossom Hill Rd. San Jose, CA 95123-1294 Santa Clara County Phone: 408-578-2912 Fax: 405-578-1148 86 | Westfield Oakridge 8.0 GENER AL INFORMATION Utiliites/Applicable Codes/Designated Engineers UTILITIES APPLICABLE CODES D E S I G N AT E D E N G I N E E R S & SUBCONTRAC TORS G A S & E L E C T R I C C O M PA N Y BUILDING: 2007 CALIFORNIA BUILDING CODE Pacific Gas & Electric Co. ELECTRICAL: 2007 CALIFORNIA BUILDING CODE REQUIRED ROOF CONTRAC TOR 111 Almaden Boulevard MECHANICAL: 2007 CALIFORNIA BUILDING CODE Alliance Roofing San Jose, CA 95191 FIRE CODE: 2007 CALIFORNIA FIRE CODE 1250 Lambell Avenue Phone: 800-743-5000 ACCESSIBILITY CODE: ADA APPLICATION FORM San Jose, CA 95126 LOCAL ORDINANCES: www. sanjoseca.gov/building Phone: 408-261-2595 T E L E P H O N E C O M PA N Y Fax: 408-261-2657 Pacific Bell Telephone & Telegraph The following is provided as a general guide only and 66 Willow Place does not release the Tenant from complying with RECOMMENDED SPRINKLER Menlo Park, CA 94025 all applicable codes and regulations, as required by RLH Fire Protection Phone: 800-750-2355 jurisdictional authorities. 5039 Preston Avenue S E W E R & WAT E R It shall be the Tenant’s responsibility to determine the Phone: 925-243-1285 San Jose Water Company edition of the above code or codes which is applicable Fax: 925-371-0368 374 West Santa Clara Street (including supplements and state amendments) as San Jose, CA 95196 codes are frequently revised and updated. Livermore, CA 94550 Phone: 408-279-7900 Hours: 8AM - 5:30PM M-F Retail Criteria Manual | 87 8.0 GENER AL INFORMATION Glossary GLOSSARY BASE BUILDING EXTENDED LEASE LINE COMMON AREA SIGN BAND Long, horizontal strip containing store signage. construction, The line, shown on the tenant lease plan, Concourse, the Food Court, Service Halls, Rest including Common and Service Areas. Excludes defining the confines of the tenant’s demised rooms, and all other areas of the Mall not part all work which is the responsibility of the premises that extends furtherinto the mall of a Tenant space. Tenant. interior than the typical lease line. Overall project envelope Artificially produced to look or seem like a MECHANICAL DIFFUSER LANDLORD BULKHEAD GLAZING Grille in the wall or ceiling connected to an Element above the Tenant’s storefront and Glass treatment (window, glass block, etc.) air duct. GRAPHICS MERCHANDISE Lettering, symbols and logos used for signage All items for sale within a given store. DEMISING PARTITION/WALL A common wall between two adjoining shops neutral pier. interior. more than one exposure to the Mall Concourse, Architectural element separating two adjacent the storefront refers to all facades. GRILLE HOUSING storefronts or a storefront and a service corridor. Enclosed housing which supports a security Neutral piers are maintained by the Landlord. position. controls all aspects of design and materials. Official name of the store as written in the Lease PARABOLIC LEASE LINE control of light, reduces glare and maintains The line, shown on the Tenant Lease Plan, better light output. and specifications which must be incorporated into the Tenant’s construction documents. TLP Tenant Lease Plan. Detailed drawing of the REVEAL lease line and Tenant Base Building design Recessed separator strip between two different information. Information contained in the TLP LIMIT OF CONSTRUCTION LINE materials. Also used to separate the Tenant’s is not guaranteed for accuracy or coordination The line, shown on the Tenant Lease Plan, storefront from the Landlord’s neutral piers and with field conditions. defining the limits beyond which the Tenant bulkheads. premises. Landlord supplied design drawings containing architectural, mechanical and electrical details documents. (Also referred to as DBA). Tenant’s Leased Premises, including important defining the confines of the Tenant’s demised DESIGN CONTROL DRAWINGS STORE NAME A type of reflective lens which provides better That area between the lease line and the Design Control Line in which the Landlord STOREFRONT NEUTRAL PIER grille and fully encloses it when in the open DESIGN CONTROL ZONE STORE CLOSURE, LINE OF CLOSURE Front face of the store. In the case of a store with at the storefront or throughout the store or between a shop and a Common Area. The demising partition extends back from the natural material. Line at which store is closed for security. below the Landlord’s ceiling. Defines maximum height of the Tenant’s storefront. SIMULATED cannot extend its storefront construction. This DUCT line is not necessarily coincidental with the An enclosed air channel for distributing lease line. SHOW WINDOW Transparent portion of the storefront used for merchandise display; display window. conditioned air. 88 | Westfield Oakridge 9.0 ADDENDA Retail Criteria Manual | 89 9.0 ADDENDA 90 | Westfield Oakridge 9.0 ADDENDA Retail Criteria Manual | 91