id+ 4.5” techzone - Focal Point Lights
Transcription
id+ 4.5” techzone - Focal Point Lights
id 4.5” techzone + ® FLC4D | FLC4W | FLC44D | FLC44W ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE. non-emergency FLC4D | FLC4W emergency key - thermally protected, non-ic FLC44D | FLC44W - integral test switch FLC4D | FLC4W round module cp FLC44D | FLC44W round downlight conduit to t-grid clip (72134) round wall wash power off power on level attention see additional instructions - emergency/non-emergency FLC4D | FLC4W | FLC44D | FLC44W square module square downlight square wall wash nivo HOUSING INSTALLATION 2 1 A TO SET CEILING THICKNESS SEE MODULE INSTALLATION ON PAGE 3 5 1/8” 4.5” 5 1/8” X2 5 1 /8 ” 4.5” x 4.5” 1/2” CONDUIT BY OTHERS Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0611 REV. A 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4 3 4 CP HOUSING 6 make electrical connections EMERGENCY - INTEGRAL TEST SWITCH 1 2 SEE BATTERY MANUFACTURER INSTRUCTIONS emergency maximum mounting height: 23.00’ WALL WASH: 19.00’ DOWNLIGHT: BATTERY UNIT CONNECTOR INSIDE CP HOUSING 3 FOR EMERGENCY INTEGRAL TEST SWITCH INSTALLATION SEE TRIM INSTALLATION ON PAGE 3 DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND A.C. POWER IS SUPPLIED Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0611 REV. A 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4 DRIVER SERVICE 1 TRIM INSTALLATION 1 2 MODULE INSTALLATION 1 measure from bottom of frame to finished ceiling to determine ceiling thickness 2 X2 set ceiling thickness EMERGENCY - INTEGRAL TEST SWITCH 3 A MAKE ELECTRICAL CONNECTION Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0611 REV. A 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4 4 5 TRIM/MODULE REMOVAL 1 DO NOT PULL ON LENS 2 Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited. IS0611 REV. A 2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4