mecon dm-i
Transcription
mecon dm-i
Product Information Sheet MECON DM-I The penetrator/Dry Mate connector (DM) is a vital part of the high voltage cable termination system, and can be used in pressure compensated systems, and as pressure barrier to penetrate shells with differential pressure. It is used to connect high voltage power cables to subsea electrical equipment, mainly subsea motors. The penetrator and cable are made up prior to deployment. MECON DM-I has the maximum rating of 12kV/600A, and its housing is pressure compensated. Design Features · The pressure barrier for MECON DM-I is a glass sealing plug which is molded into the penetrator housing · MECON DM-I complies with all IEC standards for high voltage equipment, and is verified by SINTEF energy research · Pressure and thermal shock tested MECON DM-I Applications Product Information Sheet Use in subsea electrical power systems to penetrate through high integrity barriers from a seawater environment to a clean, di-electric fluid filled enclosure; such as into: · Subsea electrical submersible pumps motors · Subsea VSD high power compartments · Subsea switchgear · Subsea distribution transformers Technical Information Voltage rating U0/U(Um) Current rating @ 50 Hz and 20°C Water depth rating/design Rated dif. pressure motor side Rated dif. pressure water side Maximum cable size Pd test <10pC AC withstand 4 hours Impulse voltage 1.2/50µs 30 Thermal cycles Short circuit Weight per phase Diameter and length per phase [kV] [A] [m] [bar] [bar] [mm²] [kV]* [kV]* [kV]* [bar,A,kV]* [kA]rms [kg] [mm] 7.2kV Pen. 3.6/6(7.2) 600 2000 345 125 240 6.2 14.4 60 125,660,9 10 25 Ø180,500 12kV Pen. 6/10(12) 600 2000 345 125 240 10.4 24 75 125,660,15 10 25 Ø180,500 * All test voltages are phase-ground values. MECON DM-I is fully qualified, with typical delivery time of 4-6 months. Two DM-Is with pigtail Vetco Gray U.K. Ltd. Silverburn House Claymore Drive, Bridge of Don Aberdeen, Scotland AB23 8GB T +44 1224 852000 F +44 1224 852434 MECON DM-I during CR measurements Vetco Gray Pte. Ltd, & Vetco Gray Controls Pte. Ltd. 2 Benoi Road Jurong Town, Singapore 629876 T +65 6861 3344 F +65 6861 5214 Vetco Gray Inc. 12221 N. Houston Rosslyn Rd. Houston, Texas 77086 T +1 281 448 4410 F +1 281 847 4679 Vetco Gray Scandanavia AS Bergerveien 12 P.O.Box 83 N-1375 Billingstad Norway T +47 66 98 53 00 F +47 66 98 56 00 ©2008 GE and Vetco Gray Inc. All rights reserved Product Information Sheet MECON DM-II The penetrator/Dry Mate (DM) is a vital part of the high voltage cable termination system, and can be used in pressure compensated systems, and as pressure barrier to penetrate shells with differential pressure. It is used to connect high voltage power cables to subsea electrical equipment. The penetrator and cable are made up prior to deployment. MECON DM-II has the maximum rating of 36kV/700A, and its housing is pressure compensated. Design Features · The pressure barrier for MECON DM-II is an epoxy moulding plug which is mounted as an insert into the penetrator housing · MECON DM-II complies with all IEC standards for high voltage equipment, and is verified by SINTEF Energy Research · Pressure and thermal shock tested MECON DM-II Applications Product Information Sheet Use in subsea electrical power systems to penetrate through high integrity barriers from a seawater environment to a clean, di-electric fluid filled enclosure; such as into: · Subsea electrical submersible pumps motors · Subsea VSD high power compartments · Subsea switchgear · Subsea distribution transformers Technical Information Voltage rating U0/U(Um) Current rating @ 50 Hz and 20°C Water depth rating/design Rated dif. pressure motor side Rated dif. pressure water side Maximum cable size Pd test <10pC AC withstand 4 hours Impulse voltage 1.2/50µs 30 Thermal cycles Short circuit Weight per phase Diameter and length per phase [kV] [A] [m] [bar] [bar] [mm²] [kV]* [kV]* [kV]* [bar,A,kV]* [kA]rms [kg] [mm] 24kV Pen. 12/20(24) 700 2000 100 200 240 21 48 125 200,660,30 10 25 450, Ø142 36kV Pen. 18/30(36) 700 2000 100 200 240 31 72 170 200,760,45 10 25 450, Ø142 * All test voltages are phase-ground values. MECON DM-II is fully qualified, with typical delivery time of 4-6 months. Two DM-IIs with pigtail Vetco Gray U.K. Ltd. Silverburn House Claymore Drive, Bridge of Don Aberdeen, Scotland AB23 8GB T +44 1224 852000 F +44 1224 852434 From PD-testing of MECON DM-II Vetco Gray Pte. Ltd, & Vetco Gray Controls Pte. Ltd. 2 Benoi Road Jurong Town, Singapore 629876 T +65 6861 3344 F +65 6861 5214 Vetco Gray Inc. 12221 N. Houston Rosslyn Rd. Houston, Texas 77086 T +1 281 448 4410 F +1 281 847 4679 Vetco Gray Scandanavia AS Bergerveien 12 P.O.Box 83 N-1375 Billingstad Norway T +47 66 98 53 00 F +47 66 98 56 00 ©2008 GE and Vetco Gray Inc. All rights reserved Product Information Sheet MECON DM-III The penetrator/Dry Mateable connector (DM) is a vital part of the high voltage cable termination system. It is used to connect high voltage power cables to subsea electrical equipment. In addition it is sealed off so that seawater does not enter into the equipment. The penetrator takes up differential pressure difference between the seawater and equipment internals. MECON DM-III has the maximum rating of 145kV/700A, and its housing is pressure compensated. MECON DM-III Design Features · The pressure barrier for MECON DM-III is an epoxy moulding plug which is mounted as an insert into the penetrator housing · MECON DM-III complies with all IEC standards for high voltage equipment, and is verified by SINTEF Energy Research · Pressure and thermal shock tested Two DM-IIIs with pigtail Applications Product Information Sheet Used in subsea electrical power systems to penetrate through high integrity barriers from a seawater environment to a clean, di-electric fluid filled enclosure; such as into: · Subsea distribution transformers · Subsea high power compartments · Subsea switchgear Technical Information Voltage rating U0/U(Um) Current rating @ 50 Hz and 20°C Water depth rating/design Rated dif. pressure motor side Rated dif. pressure water side Maximum cable size Pd test <10pC AC withstand 4 hours Impulse voltage 1.2/50µs 30 Thermal cycles Short circuit Weight per phase Diameter Length per phase [kV] [A] [m] [bar] [bar] [mm²] [kV]* [kV]* [kV] [A]* [kA] rms [kg] [mm] [mm] 76/132(145) 700 1100 10 10 240-800 114 190 650 400 42 190 Ø370 900 * DM-III is designed and verification tested. All test voltages are phase-ground values. From PD-testing of MECON DM-III Vetco Gray U.K. Ltd. Silverburn House Claymore Drive, Bridge of Don Aberdeen, Scotland AB23 8GB T +44 1224 852000 F +44 1224 852434 Vetco Gray Pte. Ltd, & Vetco Gray Controls Pte. Ltd. 2 Benoi Road Jurong Town, Singapore 629876 T +65 6861 3344 F +65 6861 5214 Vetco Gray Inc. 12221 N. Houston Rosslyn Rd. Houston, Texas 77086 T +1 281 448 4410 F +1 281 847 4679 Vetco Gray Scandanavia AS Bergerveien 12 P.O.Box 83 N-1375 Billingstad Norway T +47 66 98 53 00 F +47 66 98 56 00 ©2008 GE and Vetco Gray Inc. All rights reserved