Agela Catalog 2009-2010
Transcription
Agela technologies Chromatography Catalog 2009-2010 Best Value Guaranteed Product Quality Innovation to Benefit Customers Agela Technologies — A Global Supplier for Chromatography Solutions 2008 Message From Agela Technologies As Agela technologies is poised to enter its fifth year with confidence and pride in its innovative separation, purification, and sample preparation products, we would like to thank our many loyal customers for your continuous support and trust. With your support and our effort in delivering the highest quality products to you, our company has grown remarkably. This has allowed us to expand our research and development effort, and thus introduce more innovative products to better service your application needs. In 2007, we had tremendous accomplishments: We cataloged over one thousand different products. Our manufacturing and R&D operation was certified in compliance with ISO 9001 and passed many quality audits by customers and distributors, including VWR. As a global wide company, we not only have our own international sales force but have also formed a marketing alliance with VWR international. This will allow us to reach higher goals for 2008 and to provide our customers with even better quality products and faster service. Our 2008 mission statement and commitment: z Provide products with our INNOVATIVE technologies at the best PERFOR MANCE to COST ratio. z Deliver products with guaranteed quality. z Provide global support with quick responses How to Place Orders Our office is open from 9:00 am to 6:00 pm Eastern Standard Time, Monday through Friday. To place an order or receive a quote, you may choose from the following contacts: Mail Address: Agela Technologies Inc. 625 DAWSON DRIVE, Newark, DE19713 Phone: (302) 438-8798 Fax: (302) 235-1833 Email: [email protected] On-line: www.agela.com Please include the following information with your order or request: Account number (if you have one), purchase order number, contact name, organization name, shipping and billing address, telephone number, fax number or email address, product number, brief description and quantity, method of payment, preferred method of delivery. A written confirmation will be sent to you by email or fax. We accept business checks, wire transfers, and major credit cards as methods of payment. Checks: Please make checks payable to: Agela Technologies Inc. and send to: Agela Technologies Inc. 625 DAWSON DRIVE, Newark, DE19713 Wire Transfer: Please contact us by phone, fax or email for account information. Credit Cards: Please include the card type and number, expiration date, and card holder name. Due to security concerns, please do not email the information. Please call or send a fax to provide your credit card information. Terms and Conditions PLEASE READ THESE TERMS BEFORE ORDERING. IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO CONTACT US AND OUR STAFF WILL BE GLAD TO ASSIST YOU. Acceptance and Availability All orders placed are subject to the agreement of Agela Technologies Inc. The catalogue does not constitute an engagement of the company to sell all listed products. You are guaranteed to be notified at the time of ordering if the ordered items are in back-order or discontinued. Price and Payment The prices are in effect at the time of printing. Agela Technologies reserves the right to change the prices without notice, though we do our best to provide our customers with advance notice. The prices quoted at the time of ordering will be guaranteed. The general payment term is net 30 days, F.O.B., Newark, Delaware, USA. However we reserve the right to ask for prepayment if customers’ account information is not satisfactory. A 1.5% per month service charge will be added to delinquent accounts. If a purchase order is less than $1000.00, a $50.00 extra charge will be added to the invoice. Changes Agela Technologies reserves the right to change product specifications, quantities, designs or prices without prior notice and without liability for such changes. Shipping Policy The standard shipping method is 2 day FedEx within the United States and Canada. We will try to accommodate requests for other shipping methods if they are available. All shipping and handling charges will be billed separately. Should you receive damaged goods, it is imperative that you notify us immediately and save all packing materials for inspection by the carrier. Application All products in this catalog should be used for laboratory or manufacturing use only. They are not intended for direct medicinal or food use. Agela Technologies assumes no liability for any misuse of the products. Returns Agela Technologies tries to accommodate all requests for returns of unused goods. However, return of some items may be restricted by the original manufacturers. Please contact us for return authorization before returning any items. A restocking charge may be applied to certain products. Warranty All Agela Technologies products are warranted to be free of defects in materials and workmanship. They are not warranted for any other particular purpose. Agela Technologies shall not under any circumstance be liable for any incidental, consequential or compensatory damage in conjunction with its products. The maximum liability shall not exceed the invoice price of the product. CONTENTS HPLC Columns and Media z z z z z z z Introduction -------------------------------------------------------------------HPLC Columns by Family ----------------------------------------------------Selected Solutions for Popular Applications ------------------------------Ordering Information by the Type of Stationary Phases ---------------HPLC Column Selection Guide ----------------------------------------------Applications -------------------------------------------------------------------Appendix ----------------------------------------------------------------------- 002 002 033 044 054 058 075 SPE Columns and Wellplates Cleanert SPE Columns,Wellplates and Media ----------------------------The Development of SPE Method -----------------------------------------Applications -------------------------------------------------------------------Cross-reference Table -------------------------------------------------------- 078 103 106 114 Purification Products Preparative HPLC Columns -------------------------------------------------- 116 Flash Chromatography Media and Columns ------------------------------ 120 Flash Chromatography System --------------------------------------------- 125 GC Columns 126 Accessories and Supplies z z z z z HPLC Accessories and Supplies ---------------------------------------------SPE Accessories and Supplies ----------------------------------------------GC Accessories and Supplies -----------------------------------------------Filtration Products ------------------------------------------------------------Vials and Caps ----------------------------------------------------------------- 146 153 157 162 166 HPLC Columns and Media z z Introduction -------------------------------------------------------------------- 002 HPLC Columns by Family ---------------------------------------------------- 002 Unisol Technology and Column Products–NEW ---------------------------------Optimix Technology Column Products–NEW ------------------------------------Durashell Technology and Column Products –NEW -----------------------------Venusil Family of HPLC Columns ------------------------------------------------Promosil HPLC Columns ---------------------------------------------------------Other Manufacturers’ Brands ----------------------------------------------------- 002 011 015 017 031 032 z Selected Solutions for Popular Applications 033 033 039 040 042 043 043 043 z Ordering Information by the Type of Stationary Phases 044 044 047 049 050 051 051 z z HPLC Column Selection Guide ---------------------------------------------- 054 Applications -------------------------------------------------------------------- 058 Appendix ------------------------------------------------------------------------ 075 z ------------------------------Solutions for Highly Water Soluble Compounds ---------------------------------Solutions for Low pH and High pH Applications ---------------------------------Solutions for LC-MS -------------------------------------------------------------Solutions for Fast Analysis ------------------------------------------------------Solutions for Bio-molecules -----------------------------------------------------Solutions for Preparative HPLC -------------------------------------------------Solutions for SFC ----------------------------------------------------------------------------Reverse Phase Columns --------------------------------------------------------Normal Phase Columns ---------------------------------------------------------Ion-exchange Columns ---------------------------------------------------------Mixed Phase Columns ----------------------------------------------------------Size Exclusion Columns (Silica Based) ------------------------------------------Polymer Phase Columns --------------------------------------------------------- Introduction As one of the emerging leaders in chromatography technology, Agela Technologies proudly presents five new HPLC columns developed using our latest cutting-edge technologies. These products exhibit superior performance and are designed to meet the ever-increasing demands of our customers. 1.Unisol C18 - A type of column that is a true universal reverse phase column for the separation of acidic, basic, and neutral molecules. It has superior performance to any conventional C18 phases in almost every aspect. 2.Unisol Amide - A unique phase that is very different from other stationary phases in its separation mechanism. It can be used as a RP or a NP column. It has superior performance than any of the other HILLIC columns on the market. It has superior retention for polar compounds when operated as a HILIC column. 3.Optimix columns – A class of columns that provide optimized selectivity and performance for HPLC separations. It has balanced hydrophilicity and hydrophobicity: extended retention for polar compounds; non-excessive retention for strong hydrophobic compounds. 4.Durashell columns - A class of column that can be used in a wide pH range of 1-12. 5.Venusil ASB columns – A class of columns that are excellent for low pH and LC-MS applications. HPLC Columns by Family Unisol Technology and Column Products NEW in HPLC ! Agela’ s unique sol-gel process technology generates a uniform surface that produces a universal column applicable to many HPLC applications. Peak tailing adversely affects chromatographic efficiency and reduces the resulting accuracy and precision of the data. Peak tailing and insufficient retention of polar compounds are among the toughest problems for silica based reverse phase columns. High acidity of the surface silanols, non-uniformity of the surface, and non-uniformity of the bonding process are the three major causes of peak tailing. High purity synthetic silica is typically obtained by hydrolyzing silicic acid esters followed by high temperature sinteration. The sintered silica is further leached with dilute acid to enrich silanol on the surface. The process does not generate a uniform, silanol covered surface. It will create some isolated silanol groups with very strong acidity or some “un-leached islands” during the leaching process. Furthermore, the high temperature procedure may cause formation of micro-crystallization domains on the amorphous silica, further contributing to the nonuniformity of the surface. Unisol process technology is specifically designed to solve these problems. In our patented Unisol process, gas phase tetramethoxy silane is adsorbed evenly on the silica surface. It is subsequently hydrolyzed by a controlled amount of moisture. A fresh layer of silanols is then formed by a mild heating process. This process produces a surface with lower acidity and high uniformity, which is further bonded with a high purity C18 silane, and then di-functional end-capped. The overall process yields an excellent HPLC stationary phase with a very smooth surface that is friendly to basic compounds (minimal ionic interactions) and polar compounds (provides significantly increased retention). Major benefits of the Unisol Technology for reverse phase and normal phase chromatography: ●Greatly improved peak shape for basic compounds ●100% water compatibility ●Significantly increased retention for highly water soluble compounds and balanced hydrophobicity in the reverse phase mode ●Elimination of excessive retention for polar compounds in the normal phase mode (“hot spots”) Balanced Retention for Hydrophilic and Hydrophobic Compounds Mobile Phase: 35% 20 mM KH2PO4 pH=7.0,65% Methanol Temperature: 23℃ Flow: 1mL/min Detection: UV 254 nm Sample: Uracil Propranolol hydrochloride Butyl Phthalate Dimethyl Phthalate, Naphthalene Acenaphthene Amitriptyline Extremely Low Metal Effects Mobile Phase: A: Water, B: Methanol; A:B = 65:35 Flow Rate: 1 mL/min Temperature: 25℃ Detection: UV 230 nm Sample: 2,3-Dihydroxynaphthalene+2,7-Dihydroxynaphthalene Unisol C18 5μm, 4.6mm×150mm Brand W, AQ Column 5μm, 4.6mm×150mm VWD1 A, Wavelength=230 nm (LPF\07091702.D) VWD1 A, Wavelength=230 nm (LPF\07090605.D) Brand H, C18 Column 5μm, 4.6mm×150mm Brand Z,C18 Column 5μm, 4.6mm×150mm VWD1 A, Wavelength=230 nm (LPF\07091208.D) VWD1 A, Wavelength=230 nm (LPF\07091202.D) Unisol C18 A Slightly Polar, 100% Water Compatible and Universal Reverse Phase A unique and universal C18 HPLC phase made by our patented Unisol Technology. Unprecedented separation performance for compounds with a wide range of properties from hydrophilic to hydrophobic: polar, semi-polar and non-polar compounds. Characteristics: Metal Impurity < 10 ppm; Pore Size 100 Å; Specific Surface Area 410 m2/g; Carbon Loading 17%; Single end-cap; Available Particle Size: 2.5 μm, 3μm, 5μm, 10μm Consider this column as the first option for your HPLC method development ●One of the most universal reverse phase columns ●Great inertness and efficiency for basic compounds ●Enhanced retention of hydrophilic compounds ●100% aqueous compatibility ●Robust and reproducible performance ●Wide pH range (1.5-9.0) ●Low bleed and high sensitivity for LC-MS Great Inertness and Efficiency for Basic Compounds Good Retention for Polar Compounds Mobile Phase: A: Water (Contain 0.01mM Na2PO4 and 0.01mM Citric Acid, pH=4.5 ) B: ACN , A:B =95:5 Sample: Cytosine, Uracil, Guanine Temperature: 35℃ Sample: uracil, toluene, doxepin, amitriptyline Column: 4.6 x 150mm, 5 μm Mobile phase: 10 mM sodium phosphate (pH =7) in 60% ACN. Temperature: 30℃; Flow rate: 1 mL /min. The plate numbers in regular font are for toluene, the plate numbers in Italic are for amitriptyline Detection: 254 nm Good Tolerance of Directly Injected Biological Matrix Sample: uridine in calf blood plasma (diluted 20 times with 0.1% formic acid) Injection: 1μl (not be cleaned up with SPE) Column: Unisol C18 2.1×50mm,5μm Temperature: 30℃ Flow Rate: 0.3mL/min Mobile phase: 0.1% formic acid solution (100% aqueous phase) Run time: 8 min After 500 injection, wash with methanol /0.1% formic acid solution = 50/50 for 30mins,column temperature 40 ℃; rinse with 95%MeOH for 30mins, column Enable Methods to be Compatible with LC-MS Analysis of Quaternary Ammonium Alkaloids from Copitidis with a Non-Volatile Ion Pair Reagent using Brand Z C18 Column. Mobile Phase: ACN: 0.05 mol/L KH2PO4 Aq. (40∶60, Contain 0.015 mol/L SDS) Analysis of Quaternary Ammonium Alkaloids from Copitidis without a Non-Volatile Ion Pair Reagent Using Unisol C18 Column . Mobile Phase : Water + 0.2% TFA :acetonitrile= 75:25 Compatibility with 100% Aqueous Mobile Phase Sample: Column: Uridine 4.6 x 150 mm,5 μm Mobile phase: Flow rate: 100% water 1mL/min; the flow was stopped for 5 minutes during the testing period for each column. Temperature: 30 ℃ Greater Volume Loading Capacity Than Other Brands Large Volume Injection (Injection volume =100 μL) Sample: 4-methoxybenzenesulfon amide, 10 μg/mL in MeOH/Water (1:1) Column: 4.6 x 150 mm, 5μm Mobile phase: MeOH/Water Flow rate: 1mL/min Temperature: 30 ℃ Stability of Unisol C18 at pH=1.5 Sample: Uracil, Doxepin,Amitriptyline,Toluene. Column: Unisol C18, 4.6 x 150 mm, 5 μm Mobile phase: TFA (0.25%, pH 1.5) in 60% acetonitrile Flow rate: 1 mL/ min.; Temperature: 40 ℃ Perfect Peak Symmetry and Good Stability at Mid-pH for Basic Compounds Sample: Uracil, Doxepin, Nortriptyline,Amitriptyline, Trimipramine Column: Unisol C18, 4.6 x 250 mm, 5 μm Mobile phase: 0.01 M sodium phosphate: ACN = 25 : 75, pH=7.0 Flow rate: 1.3 mL/min. Temperature: 30 ℃ Unisol Amide (HILIC) Unisol Amide stationary phase is made from high purity spherical silica particles bonded with a neutral hydrophilic amide group. It can be used for normal phase,reverse phase, or hydrophilic interaction HPLC. The Unisol Amide (NP) column is a good replacement for NH2 and Silica columns that are currently marketed as HILIC. Compared with traditional silica and NH2 columns, the Unisol Amide columns have better reproducibility and column lifetime. It is especially useful for the separation of strong hydrophilic compounds, whether they are acidic, basic or neutral. It is compatible with aqueous mobile phases in the pH range of 2-8. It has selectivity very different from most of conventional stationary phases Characteristics: Metal Impurity < 10 ppm; Pore Size 100 Å; Specific Surface Area 410 m2/g; Carbon Loading 6%; Single End-cap; Available Particle Size: 3μm, 5μm, 10μm Main features: ●Strong retention of polar compounds in HILIC mode ●Very unique selectivity and good complementary to the conventional reverse phase ●Can be used as reverse phase, normal phase and HILIC phase ●More robust and reproducible performance than silica and amino stationary phase ●100% aqueous and 100% organic solvents compatible ●pH range (2-8) Separation of Validamycin Mobile Phase: A: 0.1% TFA in WaterB: Acetonitrile Gradient: 40% A to 85% A in 30 min Flow Rate: 1 mL/min Temperature: 25℃ Detection: Sample: UV 210 nm Validamycin Mobile Phase: A: 0.005M NaH2PO4(pH=7) ; B:MeOH A:B=98:2 Flow Rate: 1 mL/min Temperature: 25℃ Detection: Sample: UV 210 nm Validamycin Separation of Shikimic Acid Column: Unisol Amide, 5 μm, 4.6mm×150mm Part No.: UA951505-0 Mobile Phase:A: 1% Fomic Acid in Water B: Acetonitrile Gradient: 60% A to 90% A in 20 min Flow Rate: 1 mL/min Temperature: 25℃ Detection: UV 210 nm Sample: Shikimic Acid Water-soluble Vitamins Unisol Amide,5 μm, 4.6mm×150mm Brand W, NH2 Column, 5 μm, 4.6×150 mm Part No.: UA951505-0 Brand W Silica Column, 5μm, 4.6×150mm Mobile Phase:A: 0.1% TFA in Water ;B: 0.1% TFA in Acetonitrile A: B = 90:10 Flow Rate: 1 mL/min Temperature: 30℃ Detection: UV 280 nm Sample: VB1+VB6+VC+VB2 Ordering Information Surface Area: 410 m2/g, Pore Size: 100Å Dimension Particle Unisol Unisol (mm) Size(μm) C18 Amide(HILIC) Fast analysis 2.1×30 2.5 UO920302-0 Fast analysis 2.1×50 2.5 UO920502-0 Fast analysis 2.1×100 2.5 UO921002-0 Fast analysis 3.0×30 2.5 UO920303-0 Fast analysis 3.0×50 2.5 UO920503-0 Fast analysis 3.0×100 2.5 UO921003-0 Fast analysis 4.6×50 2.5 UO920505-0 Fast analysis 4.6×100 2.5 UO921005-0 Analytical 2.1×30 5 UO950302-0 VH950302-0 Analytical 2.1×50 5 UO950502-0 VH950502-0 Analytical 2.1×100 5 UO951002-0 VH951002-0 Analytical 2.1×150 5 UO951502-0 VH951502-0 Analytical 3.0×30 5 UO950303-0 VH950303-0 Analytical 3.0×50 5 UO950503-0 VH950503-0 Analytical 3.0×100 5 UO951003-0 VH951003-0 Analytical 4.6×50 5 UO950505-0 VH950505-0 Analytical 4.6×100 5 UO951005-0 VH951005-0 Analytical 4.6×150 5 UO951505-0 VH951505-0 Analytical 4.6×250 5 UO952505-0 VH952505-0 Gaurd cartridge 4.6×10 5 UO950105-0 VH950105-0 Fast analysis 2.1×30 3 UO930302-0 VH930302-0 Fast analysis 2.1×50 3 UO930502-0 VH930502-0 Fast analysis 2.1×100 3 UO931002-0 VH931002-0 Fast analysis 2.1×150 3 UO931502-0 VH931502-0 Fast analysis 3.0×30 3 UO930303-0 VH930303-0 Fast analysis 3.0×50 3 UO930503-0 VH930503-0 Fast analysis 3.0×100 3 UO931003-0 VH931003-0 Fast analysis 4.6×50 3 UO930505-0 VH930505-0 Fast analysis 4.6×100 3 UO931005-0 VH931005-0 Fast analysis 4.6×150 3 UO931505-0 VH931505-0 Gaurd cartridge 4.6×10 3 UO930105-0 VH930105-0 Semi-preparative 10×150 5 UO951510-0 VH951510-0 Semi-preparative 10×250 5 UO952510-0 VH952510-0 Preparative 20×50 5 UO950520-0 VH950520-0 Preparative 20×150 5 UO951520-0 VH951520-0 Preparative 20×250 5 UO952520-0 VH952520-0 Preparative 30×100 5 UO951030-0 VH951030-0 Preparative 30×150 5 UO951530-0 VH951530-0 Preparative 30×250 5 UO952530-0 VH952530-0 Guard cartridge 20×20 5 UO950220-0 VH950220-0 Type Optimix Technology Column Products NEW in HPLC ! Conventional silica based HPLC stationary phases are usually bonded with mono-type alkyl chain molecules, e.g., C18, C8, CN, etc. Recent studies revealed that synergistic effects can be obtained when the bonded surface consists of mixed phases of C18 and a shorter chain (C8, amide, CN, nitro-phenyl, etc). These new products offer different selectivity, coordinated multi-functionality, as well as a spacer effect (C18/C8). It is difficult to produce a uniformly bonded C18 surface on silica due to steric hindrance of the bulky C18 chain. This problem can be easily overcome when the surface is bonded with mixed chain lengths, C18 and a shorter silane. As a result, there are many advantages: improved surface uniformity, better penetration of molecules during partitioning due to less steric hindrance, and different selectivity compared to a mono-chain type stationary phase. As one of the leaders in separation technologies, Agela Technologies has innovatively developed a family of non-ionic, mixed-phase HPLC/SFC columns. Consider these columns as options for your HPLC method development Optimix C18/C8: Improved performance from a mixed-phase C18/C8 column compared to mono-chain C18 or C8 columns ●Alternative selectivity ●Improved selectivity for stereo isomers, better differentiation of shapes ●Better peak shape due to uniformity of the bonding. ●Balanced hydrophilicity and hydrophobicity: extended retention for polar compounds; non-excessive retention for strong hydrophobic compounds Characteristics: Metal Impurity < 10 ppm; Pore Size: 100 Å; Specific Surface Area: 410 m2/g; Carbon Loading: 16%; Double End-cap; Available Particle Size: 3μm, 5μm, 10μm. Analysis of Vancomycin and its impurity Column: Optimix C18 /C8,5μm 4.6×250mm, Part No.: OP952505-OC Mobile Phase: A: 0.7% TEA and 3% Acetic Acid inWater B: Methanol ;C:THF ;A:B:C(88:10:2) Flow Rate: 1 mL/min Temperature: 25℃ Detection: UV 210 nm Sample: Vancomycin+Impurity Column: Brand W C18 Column,5μm , 4.6×250mm, Mobile Phase: USP 24 A: 0.2% TEA (pH3.2)-Acetonitrile-THF(92:7:1) B: 0.2% TEA (pH3.2)-Acetonitrile-THF(70:29:1) Gradient: USP 24 Time(min) 0 12 20 22 23 30 B% 0 0 100 100 0 0 Optimix C18/Amide A mixed-phase of C18 and propionic amide provides unique selectivity which allows extremely polar and non-polar compounds to be analyzed in a single run under isocratic conditions. Characteristics: Metal Impurity < 10 ppm; Pore Size: 100 Å; Specific Surface Area : 410 m2/g; Carbon Loading : 11%; Single End-cap; Available Particle Size: 3 μm, 5 μm Performance Features: ●Unique selectivity ●Balanced retention for extremely polar and non-polar compounds ●Greater retention for polar compounds due to coordinated effects of C18 and amide ●Minimal tailing for basic compounds compared to any other type of columns, due to suppression of silanol effects by the amide group. Bring extremely polar and non-polar analytes closer to shorten the analysis time under isocratic conditions Mobile Phase:A: Water, B: Methanol Sample: Uracil, Toluene Flow rate: 1 mL/min Detection: UV = 254 nm t0= 1.52 min Column: Optimix C18/amide,5μm, 4.6×150mm Column: C18, 5μm,4.6×150mm Mobile Phase: A : B = 50 : 5 Mobile Phase: A : B = 60 : 40 Ordering Information Surface Area: 410 m2/g, Pore Size: 100Å Dimension Particle Optimix Optimix Optimix Optimix (mm) size(μm) C18/C8 C18/amide C18/phenyl C18/CN Analytical 2.1×30 5 OP950302-OC OP950302-AM OP950302-PH OP950302-CN Analytical 2.1×50 5 OP950502-OC OP950502-AM OP950502-PH OP950502-CN Analytical 2.1×100 5 OP951002-OC OP951002-AM OP951002-PH OP951002-CN Analytical 2.1×150 5 OP951502-OC OP951502-AM OP951502-PH OP951502-CN Analytical 4.6×50 5 OP950505-OC OP950505-AM OP950505-PH OP950505-CN Analytical 4.6×100 5 OP951005-OC OP951005-AM OP951005-PH OP951005-CN Analytical 4.6×150 5 OP951505-OC OP951505-AM OP951505-PH OP951505-CN Analytical 4.6×200 5 OP952005-OC OP952005-AM OP952005-PH OP952005-CN Analytical 4.6×250 5 OP952505-OC OP952505-AM OP952505-PH OP952505-CN 4.6×10 5 OP950105-OC OP950105-AM OP950105-PH OP950105-CN Fast analysis 2.1×30 3 OP930302-OC OP930302-AM OP930302-PH OP930302-CN Fast analysis 2.1×50 3 OP930502-OC OP930502-AM OP930502-PH OP930502-CN Fast analysis 2.1×100 3 OP931002-OC OP931002-AM OP931002-PH OP931002-CN Fast analysis 2.1×150 3 OP931502-OC OP931502-AM OP931502-PH OP931502-CN Fast analysis 4.6×50 3 OP930505-OC OP930505-AM OP930505-PH OP930505-CN Fast analysis 4.6×100 3 OP931005-OC OP931005-AM OP931005-PH OP931005-CN Fast analysis 4.6×150 3 OP931505-OC OP931505-AM OP931505-PH OP931505-CN 4.6×10 3 OP930105-OC OP930105-AM OP930105-PH OP930105-CN Type Guard cartridge Guard cartridge Dimension Particle Optimix Optimix Optimix (mm) size(μm) C18/SCX C18/SAX C18/Nitrophenyl Analytical 2.1×30 5 OP950302-SC OP950302-SA OP950302-NP Analytical 2.1×50 5 OP950502-SC OP950502-SA OP950502-NP Analytical 2.1×100 5 OP951002-SC OP951002-SA OP951002-NP Analytical 2.1×150 5 OP951502-SC OP951502-SA OP951502-NP Analytical 4.6×50 5 OP950505-SC OP950505-SA OP950505-NP Analytical 4.6×100 5 OP951005-SC OP951005-SA OP951005-NP Analytical 4.6×150 5 OP951505-SC OP951505-SA OP951505-NP Analytical 4.6×200 5 OP952005-SC OP952005-SA OP952005-NP Analytical 4.6×250 5 OP952505-SC OP952505-SA OP952505-NP 4.6×10 5 OP950105-SC OP950105-SA OP950105-NP Fast analysis 2.1×30 3 OP930302-SC OP930302-SA OP930302-NP Fast analysis 2.1×50 3 OP930502-SC OP930502-SA OP930502-NP Fast analysis 2.1×100 3 OP931002-SC OP931002-SA OP931002-NP Fast analysis 2.1×150 3 OP931502-SC OP931502-SA OP931502-NP Fast analysis 4.6×50 3 OP930505-SC OP930505-SA OP930505-NP Fast analysis 4.6×100 3 OP931005-SC OP931005-SA OP931005-NP Fast analysis 4.6×150 3 OP931505-SC OP931505-SA OP931505-NP 4.6×10 3 OP930105-SC OP930105-SA OP930105-NP Type Guard cartridge Guard cartridge Durashell Technology and Column Products NEW in HPLC ! Agela’ s Durashell column has a pH range of 1-12. Different from the current marketed products that also can be used at high pH,Durashell’ s stationary phase is made with a dentrimer technology followed by molecular modifications. Agela’ s technology produces a strong hydrophobic protection layer over the silica surface allowing the columns to be used at extremely high and low pH. This technology also reduces excessive hydrophobic interactions between the stationary phase and the compounds, and yet maintains great interfacial kinetics for high efficiency. Characteristics: Metal Impurity < 30 ppm; Pore Size 150 Å; Specific Surface Area 240 m2/g; Carbon Loading 15%; Double End-cap; Available Particle Size: 5μm, 10 μm Main Features: ●Wide pH range (1.5-12) ●Minimal silanol activity ●Better efficiency than many other high pH compatible columns ●High loading capacity for basic compounds for preparative applications High pH Stability Column: Durashell RP; 4.6 x 150 mm Mobile Phase: 50% ACN/50% 0.05M Ammonia (pH=9.0) Flow rate: 1.5 mL/min Sample: doxepin, nortriptyline, amitriptyline, trimipramine , Temperature: 35℃ Ordering Information Surface Area: 240m2/g, Pore Size: 150Å Particle Dimension Size(μm) (mm) Analytical 5 2.1×30 DS950302-0 Analytical 5 2.1×50 DS950502-0 Analytical 5 2.1×100 DS951002-0 Analytical 5 2.1×150 DS951502-0 Analytical 5 4.6×50 DS950505-0 Analytical 5 4.6×100 DS951005-0 Analytical 5 4.6×150 DS951505-0 Analytical 5 4.6×200 DS952005-0 Analytical 5 4.6×250 DS952505-0 Guard cartridge 5 4.6×10 DS950105-0 Fast analysis 3 2.1×30 DS930302-0 Fast analysis 3 2.1×50 DS930502-0 Fast analysis 3 2.1×100 DS931002-0 Fast analysis 3 2.1×150 DS931502-0 Fast analysis 3 4.6×50 DS930505-0 Fast analysis 3 4.6×100 DS931005-0 Fast analysis 3 4.6×150 DS931505-0 Guard cartridge 3 4.6×10 DS930105-0 Semi-preparative 5 10×150 DS951510-0 Semi-preparative 5 10×250 DS952510-0 Preparative 5 20×50 DS950520-0 Preparative 5 20×150 DS951520-0 Preparative 5 20×250 DS952520-0 Preparative 5 30×100 DS951030-0 Preparative 5 30×150 DS951530-0 Preparative 5 30×250 DS952530-0 Guard cartridge 5 20×20 DS950220-0 Semi-preparative 10 10×150 DS901510-0 Semi-preparative 10 10×250 DS902510-0 Preparative 10 20×50 DS900520-0 Preparative 10 20×150 DS901520-0 Preparative 10 20×250 DS902520-0 Preparative 10 30×100 DS901030-0 Preparative 10 30×150 DS901530-0 Preparative 10 30×250 DS902530-0 Preparative 10 50×150 DS901550-0 Preparative 10 50×250 DS902550-0 Guard cartridge 10 20×20 DS900220-0 Type Durashell RP Venusil Family of HPLC Columns Full Line of High Quality Products Introduction of Venusil HPLC Columns Venusil HPLC columns are manufactured from the highest purity spherical silica particles on the market. The outstanding properties of the HPLC phases are results of subjecting high quality silica to Agela’ s innovative surface modification and unique bonding processes. Our proprietary nanosurface modification generates a very smooth and even surface. This reduces the interaction between the silica surface and polar compounds, resulting in symmetric peak shape even for very basic compounds. Based on this technology, a series of unique columns were developed to meet the tough requirements for the analysis of highly polar compounds. Lot-to-lot reproducibility is ensured by a stable bonding/end-capping process. The uniform, spherical particles have a nominal surface area of 380m2/g, 200 m2/g or 45m2/g, with a controlled pore size of 100Å, 150Å or 300Å, respectively. All columns are packed using a consistent slurry packing process to achieve uniform and stable beds for maximum column efficiency, lifetime and column-to-column reproducibility. Unprecedented Experience in Chromatography You will experience unprecedented performance using Venusil columns for your HPLC separations Best Peak Symmetry and Efficiency The Venusil columns generate symmetric peaks with high efficiency over their entire applicable pH range,outperforming competitors columns. The pH-independent high performance feature of Venusil columns allows scientists to establish rugged methods with flexible choice of pH. Tightest Specification All our columns have tighter specification (see the table) than other brand-name columns. This ensures that all columns have great performance and identical selectivity Comparison of Specifications Waters Symmetry-C18 Zorbax XDB-C18 Venusil XBP C18 (2) 4.6×150mm, 5μm 4.6×150mm ,5μm 4.6×150mm ,5μm Spec. on efficiency N/A 8000 12000 Spec. on tailing factor(toluene) N/A 0.98-1.25 0.98-1.12 Spec. on tailing factor-amitriptyline 1.8 Spec. on N/A(typically 1.5-2.0) 1.4 +/- 10% N/A +/- 7% pH range 2-8 2-9 1.5-9 Specific Surface 300 180 380 Carbon% 16% 12% 19% selectivity(amitriptyline/acenaphthene) Characteristics of Venusil Columns Benefit to the Columns’ users Perfect peak symmetry, independent of pH Highest flexibility for any application,better sensitivity, and mobile phase greater confidence on HPLC results Broad pH range (1-10.5) Flexibility for method development Compatible with 100% aqueous mobile phase Maximum versatility Highest surface coverage Tolerance of large volume and mass injection A wide variety of chemistries Broad selection of polarity and maximum versatility Minimum buffer concentration needed Better sensitivity for LC/MS, extended column lifetime Tightest specification Better reproducibility, greater confidence on the HPLC results Excellent column efficiency Better and faster separation Great column lifetime Lower cost; greater convenience Expanding the Capabilities with the Venusil Family of C18 Columns Agela Technologies has developed a series of high quality C18 stationary phases to meet a wide range of application needs.These columns contain an ultra pure silica subjected to our patented surface deactivation process. By altering the column chemistry, we are able to tune the surface properties of the silica particles and alter selectivity to meet a variety of application needs. Many of our columns have very unique properties to address some special needs. Here are some examples: Venusil XBP-C18 (2): a phase designed for balanced adsorption to avoid excessive retention of hydrophobic compounds, • Great peak symmetry for all types of compounds, • Improved separation of stereo isomers • Extremely narrow specification during manufacture to offer high column-to-column reproducibility • Non-excessive retention for hydrophobic peaks (less peak broadening of later eluting compounds compared to other columns) Venusil ASB C18: a phase designed for low pH, low bleed (high sensitivity for LC-MS) and strong separation power for polar compounds: • Extremely low pH stability: pH limit =0.8 at 70 ℃ • Extremely low bleed offering high sensitivity for LC-MS under acidic conditions • Compatible with 100% aqueous to 100% organic mobile phases • Non-endcapped but with low surface acidity/activity compared to other non-endcapped stationary phases Venusil AQ C18: a phase designed for polar and semi-polar compounds, to be compatible with 100% water : • Compatible with 100% aqueous to 100% organic mobile phases • Applicable to a variety of analytes: from very polar to non-polar • Operates over a wide pH range: 1.0-9.0 • Applicable to a wide range of sample types: plasma, urine, drug formulation, food extraction • Available in a range of column diameters suitable for LC-MS, conventional analytical, and preparative scale Venusil XBP-C18: a phase designed for maximum hydrophobicity and high pH tolerance: • The highest carbon loading and the most hydrophobic column on the market. • High pH tolerance • Not suggested for samples containing highly hydrophobic compounds Venusil XBP-C18 (L): a phase designed for larger molecules and highly hydrophobic compounds: • Larger pore size and lower surface area • Accelerated elution for highly hydrophobic compounds • Easier column clean-up for samples containing hydrophobic impurities or samples extracted by non-polar solvents • Better choice for molecules > 500 Dalton Venusil XBP C18 (2) Series Columns Venusil XBP C18 (2) column packing material is made with ultra pure silica. The silica surface is processed with Agela’ s patented surface deactivation technology, followed by a unique bonding process that can reduce the carbon content while maintaining a high bonding coverage. The Venusil XBP C18 column does not have excessive retention for highly hydrophobic compounds, and it is great for the separation of acidic, basic, and neutral compounds. Moreover, this column also has superb resolution power for isomers. The perfect peak symmetry offered by this RP column makes it a great first-choice for HPLC method development. Universal, Highly Inert C18 Columns z Balanced hydrophobic adsorption which results in a broader suitability z Stronger separation power for isomers z Great column-to-column and batch-to-batch reproducibility z Perfect symmetry for basic, acidic and neutral compounds A good replacement of Luna C18 (2) columns! Technical Parameters z Metal Impuriy < 10ppm z Particle Size: 5μm, 3μm, 10μm z Specific Surface: 380m2/g z Pore Size: 100Å z Carbon Loading: 19% z Double End-cap z pH Range: 1.5-9.0 z Performance: Efficiency>80,000/m (5μm) z TF: 0.98-1.12 Hydrophobicity Test Column: Sample: Venusil XBP C18 (2), 4.6 × 150mm, 5 μm Uracil, Toluene Mobile phase: MeOH: 25 mM KH2PO4/K2HPO4 (pH 6.0) = 80 : 20 Inertness Test Detection: UV 254 nm Flow rate: 1mL/min Column: Sample: Venusil XBP C18 (2), 4.6 × 150mm, 5 μm Amitriptyline Mobile phase: NaH2PO4/Na2HPO4 ( 20mM, pH 6.9): MeOH = 29 : 71 Detection: UV 254 nm Flow rate: 1mL/min Amitriptyline is a strong basic antidepressant. It is recognized as a compound difficult to obtain good peak shape; But the XBP C18(2)column performed outstandingly and gave a great peak symmetry (TF = 1.12). Extremely Low Metal Effects Selectivity of Basic Compounds Mobile Phase: Water :Methanol=65:35 Mobile Phase: MeOH:Acetic Acid/ sodium acetate Flow Rate: aq. 1 mL/min Temperature: 35℃ (pH 5.0)=60:40 Detection: UV 230 nm Flow Rate: Sample: 2,3-Dihydroxynaphthalene+2,7 Temperature: 30℃ -Dihydroxynaphthalene Detection: 1 mL/min UV 254 nm Ordering Information Surface Area: 380m2/g,Pore Size: 100Å Type Dimension (mm) Particle size(μm) Venusil XBP-C18 (2) Analytical 2.1×30 5 VX950302-2 Analytical 2.1×50 5 VX950502-2 Analytical 2.1×100 5 VX951002-2 Analytical 2.1×150 5 VX951502-2 Analytical 4.6×50 5 VX950505-2 Analytical 4.6×100 5 VX951005-2 Analytical 4.6×150 5 VX951505-2 Analytical 4.6×250 5 VX952505-2 Guard cartridge 4.6×10 4/pk 5 VX950105-2 Venusil XBP Series Columns Venusil XBP C18 Venusil XBP C18 columns have the maximum bonding density therefore the highest hydrophobicity (the lowest polarity). This allows for the least interaction between the analytes and the silanol groups. Venusil XBP columns have extraordinary column stability at high pHs. Pore size: 100Å, 300 Å; Specific surface: 380 m2/g,45m2/g; Purity > 99.999%; 1) Inertness: one of most base-friendly columns. 2) Efficiency: excellent at any applicable pH. 3) Large volume injection: maintain very high efficiency with very large injection volumes. 4) Broad pH range (1.5 – 10.0 ): low pH, 0.2 % TFA; high pH,0.010 M triethylamine. Other Venusil XBP Columns: A complete line of stationaryphases include C8, C4, C1, NH2, Phenyl, CN, Silica, SCX,SAX; Quality of Column Packing Perfect Peak Symmetry and Great Lifetime of the Column for Basic Compounds at Mid-pH Sample: uracil, phenol,chloronitrobenzene, Sample: toluene(in methanol/water=50/50) Column: 2.1 x 50 mm, 5 μm Uracil, Doxepin,Nortriptyline,Amitriptyline, Trimipramine Column: Venusil XBP-C18, 4.6 x 150 mm, 5 μm Mobile phase: methanol: water = 65: 35 Mobile phase: Flow rate: Flow rate: 1.5 mL/min Temperature: 45 ℃ 0.20 mL/min Temperature: 30 ℃ 0.01 M sodium phosphate: ACN= 50 : 50, pH=7.6 Comparison of Venusil-C8 Phases Plates (Toluene) Tailing Factor Brand Z-C8 3805 1.12 Luna C8 2546 1.15 Venusil XBP-C8 4012 1.03 Ordering Information Surface Area: 380m2/g,Pore Size: 100Å Dimension Particle Venusil Venusil Venusil Venusil (mm) (μm) XBP-C18 XBP-C8 XBP-C4 XBP-C1 Analytical 2.1×30 5 VX950302-0 VX850302-0 VX450302-0 VX150302-0 Analytical 2.1×50 5 VX950502-0 VX850502-0 VX450502-0 VX150502-0 Analytical 2.1×100 5 VX951002-0 VX851002-0 VX451002-0 VX151002-0 Analytical 2.1×150 5 VX951502-0 VX851502-0 VX451502-0 VX151502-0 Analytical 4.6×50 5 VX950505-0 VX850505-0 VX450505-0 VX150505-0 Analytical 4.6×100 5 VX951005-0 VX851005-0 VX451005-0 VX151005-0 Analytical 4.6×150 5 VX951505-0 VX851505-0 VX451505-0 VX151505-0 Analytical 4.6×200 5 VX952005-0 VX852005-0 VX452005-0 VX152005-0 Analytical 4.6×250 5 VX952505-0 VX852505-0 VX452505-0 VX152505-0 Guard cartridge 4.6×10 4/pk 5 VX950105-0 VX850105-0 VX450105-0 VX150105-0 Fast analysis 2.1×30 3 VX930302-0 VX830302-0 Fast analysis 2.1×50 3 VX930502-0 VX830502-0 Fast analysis 2.1×100 3 VX931002-0 VX831002-0 Fast analysis 2.1×150 3 VX931502-0 VX831502-0 Fast analysis 4.6×50 3 VX930505-0 VX830505-0 Fast analysis 4.6×100 3 VX931005-0 VX831005-0 Fast analysis 4.6×150 3 VX931505-0 VX831505-0 Guard cartridge 4.6×10 4/pk 3 VX930105-0 VX830105-0 Semi-preparative 10×150 5 VX951510-0 VX851510-0 Semi-preparative 10×250 5 VX952510-0 VX852510-0 Preparative 20×50 5 VX950520-0 VX850520-0 Preparative 20×150 5 VX951520-0 VX851520-0 Preparative 20×250 5 VX952520-0 VX852520-0 Preparative 30×100 5 VX951030-0 VX851030-0 Preparative 30×150 5 VX951530-0 VX851530-0 Preparative 30×250 5 VX952530-0 VX852530-0 Guard cartridge 20×10 5 VX950120-0 VX850120-0 Semi-preparative 10×150 10 VX901510-0 VX801510-0 Semi-preparative 10×250 10 VX902510-0 VX802510-0 Preparative 20×50 10 VX900520-0 VX800520-0 Preparative 20×150 10 VX901520-0 VX801520-0 Preparative 20×250 10 VX902520-0 VX802520-0 Preparative 30×100 10 VX901030-0 VX801030-0 Preparative 30×150 10 VX901530-0 VX801530-0 Type Preparative 30×250 10 VX902530-0 VX802530-0 Preparative 50×150 10 VX901550-0 VX801550-0 Preparative 50×250 10 VX902550-0 VX802550-0 Guard cartridge 20×10 10 VX900120-0 VX800120-0 Surface Area: 380m2/g,Pore Size: 100Å Dimension Particle Venusil Venusil Venusil Venusil (mm) (μm) XBP-NH2 XBP-Phenyl XBP-CN Type Silica Analytical 2.1×30 5 VN850302-0 VX650302-0 VC950302-0 VSi950302-0 Analytical 2.1×50 5 VN850502-0 VX650502-0 VC950502-0 VSi950502-0 Analytical 2.1×100 5 VN851002-0 VX651002-0 VC951002-0 VSi951002-0 Analytical 2.1×150 5 VN851502-0 VX651502-0 VC951502-0 VSi951502-0 Analytical 4.6×50 5 VN850505-0 VX650505-0 VC950505-0 VSi950505-0 Analytical 4.6×100 5 VN851005-0 VX651005-0 VC951005-0 VSi951005-0 Analytical 4.6×150 5 VN851505-0 VX651505-0 VC951505-0 VSi951505-0 Analytical 4.6×200 5 VN852005-0 VX652005-0 VC952005-0 VSi952005-0 Analytical 4.6×250 5 VN852505-0 VX652505-0 VC952505-0 VSi952505-0 4.6×10 4/pk 5 VN850105-0 VX650105-0 VC950105-0 VSi950105-0 Type Guard cartridge Surface Area: 45m2/g, Pore Size: 300Å Dimension Particle Venusil Venusil Venusil Venusil (mm) (μm) XBP-C18 XBP-C8 XBP-C4 XBP-C1 Analytical 2.1×30 5 VX950302-T VX850302-T VX450302-T VX150302-T Analytical 2.1×50 5 VX950502-T VX850502-T VX450502-T VX150502-T Analytical 2.1×100 5 VX951002-T VX851002-T VX451002-T VX151002-T Analytical 2.1×150 5 VX951502-T VX851502-T VX451502-T VX151502-T Analytical 4.6×50 5 VX950505-T VX850505-T VX450505-T VX150505-T Analytical 4.6×100 5 VX951005-T VX851005-T VX451005-T VX151005-T Analytical 4.6×150 5 VX951505-T VX851505-T VX451505-T VX151505-T Analytical 4.6×200 5 VX952005-T VX852005-T VX452005-T VX152005-T Analytical 4.6×250 5 VX952505-T VX852505-T VX452505-T VX152505-T Guard cartridge 4.6×10 4/pk 5 VX950105-T VX850105-T VX450105-T VX150105-T Semi-preparative 10×150 5 VX951510-T VX851510-T Semi-preparative 10×250 5 VX952510-T VX852510-T Preparative 20×50 5 VX950520-T VX850520-T Preparative 20×150 5 VX951520-T VX851520-T Preparative 20×250 5 VX952520-T VX852520-T Guard cartridge 20×10 5 VX950120-T VX850120-T Dimension Particle Venusil Venusil Venusil Venusil (mm) (μm) XBP-NH2 XBP-Phenyl XBP-CN Type Silica Type 2 Surface Area: 45m /g,Pore Size: 300Å Type Analytical 2.1×30 5 VN850302-T VX650302-T VC950302-T VSi950302-T Analytical 2.1×50 5 VN850502-T VX650502-T VC950502-T VSi950502-T Analytical 2.1×100 5 VN851002-T VX651002-T VC951002-T VSi951002-T Analytical 2.1×150 5 VN851502-T VX651502-T VC951502-T VSi951502-T Analytical 4.6×50 5 VN850505-T VX650505-T VC950505-T VSi950505-T Analytical 4.6×100 5 VN851005-T VX651005-T VC951005-T VSi951005-T Analytical 4.6×150 5 VN851505-T VX651505-T VC951505-T VSi951505-T Analytical 4.6×200 5 VN852005-T VX652005-T VC952005-T VSi952005-T Analytical 4.6×250 5 VN852505-T VX652505-T VC952505-T VSi952505-T Guard cartridge 4.6×10 4/pk 5 VN850105-T VX650105-T VC950105-T VSi950105-T Venusil XBP (L) Series Columns XBP (L) C18 has an identical bonded phase as XBP C18. However, XBP (L) C18 has relatively low surface area which allows compounds to have shorter retention times. These columns are an excellent alternative to Hypersil BDS-C18, Hypersil BDS-C8; Zorbax XDB-C18, Zorbax XDB-C8 which comparitively could have too much retention. XBP (L) C18 have relatively larger pore size (150Å) and are suitable for the separation of large molecules. Surface Area: 200m2/g, Pore Size: 150Å Dimension Particle Venusil Venusil Venusil (mm) (μm) XBP(L) C18 XBP(L) C8 XBP(L) Silica Analytical 2.1×30 5 VX950302-L VX850302-L VSi950302-L Analytical 2.1×50 5 VX950502-L VX850502-L VSi950502-L Analytical 2.1×100 5 VX951002-L VX851002-L VSi951002-L Analytical 2.1×150 5 VX951502-L VX851502-L VSi951502-L Analytical 4.6×50 5 VX950505-L VX850505-L VSi950505-L Analytical 4.6×100 5 VX951005-L VX851005-L VSi951005-L Analytical 4.6×150 5 VX951505-L VX851505-L VSi951505-L Analytical 4.6×250 5 VX952505-L VX852505-L VSi952505-L Type StationaryPhase Specific Pore SurfaceArea Size 2 (Å) (m /g) Particle Carbon Size pH Loading Available Range Characteristics (μm) Balanced adsorption to avoid excessive reten-tion; a wider range of suitability; Venusil XBP-C18(2) 380 100 19% 3, 5, 10 1.5 perfect peak symmetry for acidic, basic and neutral com-pounds; greater separation power for isomers. The most hydrophobic adsorption; better Venusil XBP-C18 380 100 22% 3, 5, 10 1.5 high pH tolerance; not suggested for samples which contain highly hydrophobic compounds. Larger pore size and lower surface area;a Venusil XBP-C18(L) 200 150 15% 3, 5, 10 1.5 better choice for the analysis of large molecule and strong hydrophobic compounds. Slightly polar C18 and enhanced Venusil AQ C18 380 100 18% 3, 5, 10 1 retention for polar compounds; 100% water compatible; good peak shape for acidic, basic and neutral compounds. Polar C18; extremely low bleed at low Venusil ASB-C18 200 150 12% 3, 5, 10 0.8 pH; great for LC-MS and peptide separation; stable at pH as low as 0.8 at 70℃. Venusil AQ-C18 Columns The Venusil AQ-C18 column is designed for the separation of polar, semi-polar and non-polar compounds at low to medium pH. This column is more polar than XBP-C18, but less polar than ASB-C18. With a special surface treatment, Venusil AQ-C18 is made to be compatible with 100% aqueous mobile phases., and it can be used to replace Waters Symmetry, Inertsil C18, Zorbax SB, Atlantis dC18, and other AQ columns. This column has a pH range of 1.5-9.0. Pore size: 100 Å; Specific surface: 380 m2/g; Purity > 99.999%; 1) Inertness: one of most base-friendly columns, excellent peak symmetry of basic compounds. 2) Efficiency: The best column for polar compounds at any pH. 3) Large volume injection: maintains very high efficiency even if the injection volume is exceptionally large. 4) 100% water compatible: very unique for a universal C18 column; much better peak shape, retention, and efficiency than other brand AQ columns. 5) Low pH stability (pH=1.5):better stability than most of the popular brand columns (including other brand AQ columns) on the market. Compatibility with 100% Aqueous Mobile Phase Sample: Ranitidine Column: 4.6×150mm,5μm Mobile phase: 100% Water Flow rate: 1mL/min; the flow was stopped for 5 minutes during the testing period for each column. Temperature: 30℃ Balanced Retention for Hydrophilic and Hydrophobic Compounds Mobile Phase: 35% v/v 20.0 mM KH2PO4/K2HPO4 at pH7.00/65% Methanol at 23℃ Flow: 1mL/min Detection: UV 254nm Sample: Uracil Propranolol hydrochloride Butyl ,Phthalate Dimethyl Phthalate Naphthalene ,Acenaphthene Amitriptyline Great Peak Shape for All Type of Compounds Mobile Phase:1% Acetic Acid (pH=2.57) :MeOH =50:50 Flow : 1mL/min Temperature: 30℃ Detection: Sample: 275nm Uracil、Paracetamol、acetophenone and 2-Hydroxybenzoic acid Ordering Information Surface Area: 380m2/g,Pore Size: 100Å Type Dimension Particle Venusil (mm) (μm) AQ-C18 Analytical 2.1×30 5 VA950302-0 Analytical 2.1×50 5 VA950502-0 Analytical 2.1×100 5 VA951002-0 Analytical 2.1×150 5 VA951502-0 Analytical 4.6×50 5 VA950505-0 Analytical 4.6×100 5 VA951005-0 Analytical 4.6×150 5 VA951505-0 Analytical 4.6×250 5 VA952505-0 Guard cartridge 4.6×10 4/pk 5 VA950105-0 Fast analysis 2.1×30 3 VA930302-3 Fast analysis 2.1×50 3 VA930502-0 Fast analysis 2.1×100 3 VA931002-0 Fast analysis 2.1×150 3 VA931502-0 Fast analysis 4.6×50 3 VA930505-0 Fast analysis 4.6×100 3 VA931005-0 Fast analysis 4.6×150 3 VA931505-0 Guard cartridge 4.6×10 4/pk 3 VA930105-0 Semi-preparative 10×150 5 VA951510-0 Semi-preparative 10×250 5 VA952510-0 Preparative 20×50 5 VA950520-0 Preparative 20×150 5 VA951520-0 Preparative 20×250 5 VA952520-0 Preparative 30×100 5 VA951030-0 Preparative 30×150 5 VA951530-0 Preparative 30×250 5 VA952530-0 Guard cartridge 20×10 5 VA950120-0 Venusil ASB Columns The Venusil ASB column is specially designed for the separation of polar compounds from low (extremely stable at pH=1) to medium pH. The stationary phase is end-capped with polar groups and thus has the highest polarity among all Venusil family columns. This column can be used to replace Water Atlantis, Zorbax SB, and other brand AQ columns. Pore size: 150Å; Specific surface: 200m2/g; Purity>99.999% 1) Low pH stability: great stability even at pH=1 2) Peak shape and efficiency: Excellent peak symmetry for basic compounds comparing to other brand polar phase columns 3) Polar C18 phase: Very strong separation power for polar compounds 4) 100% aqueous compatible: Much better peak shape, retention, and efficiency comparing to other brand “AQ” columns. The Stability in the Low pH Column: Venusil ASB C18, 5μm, 4.6×150mm Sample: Naphthol Aging: 40 ℃, TFA in 80% methanol (pH=1.0), 400 hours Mobile Phase:TFA in 80% methanol (pH=1.5) Flow Rate: 1 mL/min Injection: 5 μL Temperature: 30℃ The separation of Organic Acid Column: Venusil ASB C18, 5μm, 4.6×150mm Sample: Vc, malonic acid, lactic acid, citric acid Mobile Phase:20 mM Phosphate buffer saline (PBS) , pH=2.0 Flow Rate: 1 mL/min Injection: 5 μL Detection: UV 210 nm Ordering Information Surface: 200m2/g,Pore size: 150Å Dimension Particle Venusil Venusil Venusil (mm) (μm) ASB-C18 ASB-C8 ASB-Phenyl Analytical 2.1×30 5 VS950302-0 VS850302-0 VS650302-0 Analytical 2.1×50 5 VS950502-0 VS850502-0 VS650502-0 Analytical 2.1×100 5 VS951002-0 VS851002-0 VS651002-0 Analytical 2.1×150 5 VS951502-0 VS851502-0 VS651502-0 Analytical 4.6×50 5 VS950505-0 VS950505-0 VS650505-0 Analytical 4.6×100 5 VS951005-0 VS851005-0 VS651005-0 Analytical 4.6×150 5 VS951505-0 VS851505-0 VS651505-0 Analytical 4.6×250 5 VS952505-0 VS852505-0 VS652505-0 Guard cartridge 4.6×10 4/pk 5 VS950105-0 VS850105-0 VS650105-0 Semi-preparative 10×150 5 VS951510-0 VS851510-0 Semi-preparative 10×250 5 VS952510-0 VS852510-0 Preparative 20×50 5 VS950520-0 VS850520-0 Preparative 20×150 5 VS951520-0 VS851520-0 Preparative 20×250 5 VS952520-0 VS852520-0 Guard cartridge 20×10 5 VS950120-0 VS850120-0 Type 2 Surface Aera: 45m /g,Pore Size: 300Å Dimension Particle Venusil Venusil (mm) (μm) ASB-C18 ASB-C8 Analytical 2.1×30 5 VS950302-T VS850302-T Analytical 2.1×50 5 VS950502-T VS850502-T Analytical 2.1×100 5 VS951002-T VS851002-T Analytical 2.1×150 5 VS951502-T VS851502-T Analytical 4.6×50 5 VS950505-T VS850505-T Analytical 4.6×100 5 VS951005-T VS851005-T Analytical 4.6×150 5 VS951505-T VS851505-T Analytica 4.6×250 5 VS952505-T VS852505-T Guard cartridge 4.6×10 4/pk 5 VS950105-T VS850105-T Type Venusil SCX HPLC Columns SCX HPLC Column: made of spherical silica particles of the highest purity (>99.999%), bonded with aromatic sulfonic acid group.They can be used forthe separation of basic, water-soluble compounds and bio-molecules. Ordering Information Surface Aera: 200m2/g,Pore Size: 150Å Type Dimension (mm) Particle (μm) Venusil SCX Analytical 4.6×100 5 VSc951005-0 Analytical 4.6×150 5 VSc951505-0 Analytical 4.6×250 5 VSc952505-0 Guard cartridge 4.6×10 4/pk 5 VSc950105-0 2 Surface Aera: 50m /g,Pore Size: 300Å Type Dimension (mm) Particle (μm) Venusil SCX Analytical 4.6×100 5 VSc951005-T Analytical 4.6×150 5 VSc951505-T Analytical 4.6×250 5 VSc952505-T Guard cartridge 4.6×10 4/pk 5 VSc950105-T Venusil SAX HPLC Columns SAX HPLC Column: the stationary phase is made with high purity spherical silica particles and bonded with quaternary amine groups.The column can be used for the separation of acidic, water-soluble compounds and bio-molecules Ordering Information Surface Aera: 200m2/g,Pore Size: 150Å Type Dimension (mm) Particle (μm) Venusil SAX Analytical 4.6×100 5 VSa951005-0 Analytical 4.6×150 5 VSa951505-0 Analytical 4.6×250 5 VSa952505-0 Guard cartridge 4.6×10 4/pk 5 VSa950105-0 2 Surface Aera: 50m /g,Pore Size: 300Å Type Dimension (mm) Particle (μm) Venusil SAX Analytical 4.6×100 5 VSa951005-T Analytical 4.6×150 5 VSa951505-T Analytical 4.6×250 5 VSa952505-T Guard cartridge 4.6×10 4/pk 5 VSa950105-T Promosil HPLC Columns Using the silica of high-purity and high mechanical strength, the Promosil C18s are made with high-purity monosilane through Agela Technologies’ well controlled bonding process. They have high surface bonding coverage and completely capped. The carbon content is as much as 18%. They are stable at pH range 1.5-9.0 showing good peak shape for acidic and basic compounds. They have excellent tolerance of contamination and long life-time. They are the best choice of high performance-to-cost value. z Double End-cap, Good Inertness z Good Stability and Reproducibility z Excellent Performance-to-cost Value Technical Parameters: z High-purity silica, Metal Impurity<10ppm z Average Particle Size: 5μm z Specific Surface: 320m2/g z Pore Size: 100Å z Carbon Loading: 18% z pH Range: 1.5-9.0 z Efficiency: >80, 000/m z TF: 0.98-1.20 Hydrophobicity Test Column: Promosil C18, 4.6 × 150mm, 5 μm Sample: Uracil, Toluene Mobile phase: MeOH: 25 mM KH2PO4/K2HPO4 ( pH 6.0 ) = 80 : 20 Detection: UV 254 nm Flow rate: 1mL/min Inertness Test Column: Promosil C18, 4.6 × 150mm, 5 μm Sample: Amitriptyline Mobile phase: NaH2PO4/Na2HPO4 (20mM, pH 6.9): MeOH = 32 : 68 Detection: UV 254 nm Flow rate: 1mL/min Ordering Information Surface area: 320m2/g,Pore size: 100Å Dimension (mm) Particle (μm) Promosil Promosil Promosil Promosil Promosil C18 C8 NH2 CN Silica 2.1×30 5 PM950302-0 PM850302-0 PM750302-0 PM550302-0 PM050302-0 2.1×50 5 PM950502-0 PM850502-0 PM750502-0 PM550502-0 PM050502-0 2.1×100 5 PM951002-0 PM851002-0 PM751002-0 PM551002-0 PM051002-0 2.1×150 5 PM951502-0 PM851502-0 PM751502-0 PM551502-0 PM051502-0 4.6×50 5 PM950505-0 PM850505-0 PM750505-0 PM550505-0 PM050505-0 4.6×100 5 PM951005-0 PM851005-0 PM751005-0 PM551005-0 PM051005-0 4.6×150 5 PM951505-0 PM851505-0 PM751505-0 PM551505-0 PM051505-0 4.6×250 5 PM952505-0 PM852505-0 PM752505-0 PM552505-0 PM052505-0 4.6×10, 4/pk 5 PM950105-0 PM850105-0 PM750105-0 PM550105-0 PM050105-0 Other Manufacturers’ Brands Agela Technologies may also supply a number of major brand name HPLC columns made by other manufacturers, as listed below. Please contact us for availability and price information. These brands are: Zobax, Kromasil, Hypersil, ES-Industry, Shodex, Jordi Selected Solutions for Popular Applications Solutions for Highly Water Soluble Compounds: Venusil AQ C18 Venusil ASB C18 Unisol Amide It is known that highly water-soluble compounds often have difficulties in HPLC analysis, such as lack of retention, bad peak shape and inconsistent results. A large scientific effort has been made in developing HPLC stationary phases that can provide solutions to these problems. However, no single stationary phase may resolve all these difficulties. Agela Technologies has developed a series of stationary phases along with development schemes to help chemists systematically develop methods for the analysis of highly water-soluble compounds. The series includes two reverse stationary phases which are compatible with 100% water and one strong hydrophilic interaction stationary phase which has a neutral functionality on its surface. Some application examples are included as a guide to your column selection. Venusil AQ-C18 is a slightly-polar C18 column, and it is our most versatile high aqueous reverse phase column. Venusil AQ-C18 has a broad pH suitability (1.5-9.0) and thus can be your first option for most of your HPLC applications. Venusil ASB-C18 has pH range of 0.8-7.0. The column stationary phase is non-end capped polar C18 and good for low pH conditions. Unisol Amide (HILIC) has a pH range of 2-8 . Unisol Amide column stationary phase is modified with strong hydrophilic and neutral functionalities, it has hydrophilic interaction with the compounds. Unisol Amide provides the strongest retention to hydrophilic compounds among these three types of columns. In general, your method development may start with a Venusil AQ-C18 column and a mobile phase containing a mixture of methanol or acetonitrile with an aqueous acidic buffer solution (pH=2-5). This approach may be applicable to the HPLC analysis of more than 50% of small molecules (<2000 daltons). If required, you can minimize the percentage of the stronger organic mobile phase to increase retention by using up to 100% aqueous acidic buffer mobile phase. In the cases that you achieve adequate retention, but not enough resolution for the compounds of your interest, you may chose to adjust mobile phase ratio, mobile phase pH (very effective for ionizable compounds), or chose to replace the column with a Venusil ASB-C18 or Unisol Amide for an alternative selectivity. Figure 1 shows an HPLC separation of four organic acids using Unisol C18 column in 100% aqueous mobile phase at pH=2. In the cases that you cannot achieve adequate retention after analysis in 100% aqueous mobile phase using the Venusil AQ-C18, you have the following options depending on the type of compounds. For acidic compounds, you may try ASB-C18 columns and lower the pH to further reduce the solubility of the compounds in water. For such low pH applications, TFA is the preferred acidic modifier. TFA may give you the highest retention of both acidic and basic compounds than other organic or inorganic acidic modifiers. If necessary, you may also try a Unisol Amide column in HILIC mode for even higher retention and/or different selectivity. When using a Unisol Amide column, it will behave like a NP column. More polar compounds will elute later than less polar compounds. Figure 2 shows a good separation of highly water-soluble shikimic acid and related substances using a Unisol Amide column. The retention of these compounds was not adequate for analysis on either an AQ-C18 or an ASB-C18 column. For basic compounds, you may start with a AQ- C18 column. For compounds with pKa > 9, another alternative is to use a Unisol Amide column in place of the AQ- C18 column and operate at a low to medium pH (2-7). Figure 3 shows that even with a 100% aqueous mobile phase, validamycin (basic and highly water soluable) still has poor retention on a AQ-C18 column. However, a Unisol Amide column operating at pH 2 in the hydrophilic interaction mode resulted in a suitable validamycin separation. For neutral compounds, changing pH will have a limited effect on retention. If a suitable method cannot be developed using an AQ-C18 column, an ASB-C18 or Unisol Amide column may be required. Usually during method development, the desired retention is achieved first, then the mobile phase pH and ratio is further adjusted to get the desired resolution. When the desired retention or resolution cannot be obtained for highly water soluble compounds using a AQ-C18 or ASB-C18 columns, a Unisol Amide column will be a good alternative. Unisol Amide columns offer completely different selectivity from reverse phase columns and offer much higher retentivity. The multiple selection of columns and this comprehensive method development scheme for the separation of highly water-soluble compounds will allow you to develop HPLC methods at ease. Figure 2. HPLC Analysis of Shikimic Acid Figure 1. HPLC Separation of Organic Acids (3,4,5-Trihydroxy-1-cyclohexene-1-carboxylic Acid) Sample: Vitamin C, malonic acid, lactic acid, citric Column: Column: Unisol Amide (HILIC) 4.6 x 250 mm, 5 μm acid. AQ-C18, 4.6 x 150mm, 5 μm Mobile phase:ACN/1% formic acid 90-60% in 20 min Mobile phase:20mmol phosphate buffer,pH=2.0 Detection: UV 210nm Detection: Flow rate: 1.0 mL/min Flow rate: UV 210nm 1.0 mL/min Temperature: 30℃ Temperature: 30℃ Figure 3. HPLC Analysis of Validamycin Raw Products Column: Waters Atlantis C18, 4.6 x 250 mm, 5 μm Column: Unisol Amide (HILIC) 4.6 x 250 mm, 5 μm Mobile phase: TFA 1% Mobile phase: ACN/0.1%TFA 85-40% in 30 min Flow rate: Detection: UV 210nm Flow rate: 1.0 mL/min 1.0 mL/min Temperature: Ambient Other Stationary Phases from Agela Technologies for Hydrophilic Compounds Separation: Unisol C18 Venusil XBP-Silica (HILIC II) Venusil XBP-NH2 (HILIC III) Venusil ASB C18 DAD1 A, Sig=240, 4 Ref=360,100 (AGELA\07052506.D) Venusil ASB C18(4.6×250 mm,5 μm) Column: (VS952505-0) Mobile Phase:100mM NH4AC:ACN=95:5 Detection: 240 nm Flow rate: 1mL/min Temperature: 40℃ Sample: Melamine in Feed Unisol C18 Column: Unisol C18; 4.6 × 150 mm Mobile Phase: A: NH4AC Buffer (Adjust pH 6.0) B: ACN Gradient: 10% B to 60% B in 20 min. Flow rate: 1.0 mL/min Sample: Teicoplanin+Impurity Temperature: 35℃ Column: Unisol C18 4.6×150mm ( UO951505-0) Mobile Phase: Water:ACN:THF (50:50:1,0.1%H3PO4) Flow Rate: 1mL/min Sample: Nicousamide Detection: UV 254nm HILIC Column Family From Agela Technologies Unisol Amide ( Agela HILIC ) Venusil XBP-Silica ( Agela HILIC II) Venusil XBP-NH2 (Agela HILIC III) Comparison: ●Selectivity XBP-silica is slightly acidic (pH=5.6); while Unisol Amide is slightly basic (pH=7-9), and XBP-NH2 is more basic (pH=9.2). XBP-silica has stronger retention of basic compounds, while Unisol Amide and XBP-NH2 have better retention of acidic compounds. Unisol Amide has a balanced retention power for neutral, acidic and basic compounds, and thus the highest versatility. ●Reproducibility and Lifetime Unisol Amide has the best reproducibility and lifetime because of a bonded and close-to-neutral protection layer. Water-soluble Vitamins ●Selectivity comparison on 3 Columns ●Stability comparison of Unisol Amide and silica Unisol Amide Column, 5μm, 4.6mm×150mm Part No.: UA951505-0 XBP -NH2 Column, 5μm, 4.6×150mm XBP-Silica Column, 5μm, 4.6×150mm Mobile Phase: A: 0.1% TFA in Water ; B: 0.1% TFA in Acetonitrile ; A:B =90:10 Flow Rate: 1 mL/min Temperature: 30℃ Detection: UV 280 nm Sample: VB1+VB6+VC+VB2 Stability Comparison of Unisol Amide and Silica Samples:VB1, VB6, VC, VB2 Aging Conditions: MeOH:20 mM NaH2PO4 (pH=7.00) = 40 : 60; 1.0mL/min;Temp:40℃; HPLC Conditions: Mobile Phase: 0.1%TFA : ACN=90:10 Detection: 280nm; Flow: 1.0 mL/min; Temp: 30?;Inj: 2 μL Validamycin Validamycin Mobile Phase: A: 0.1% TFA in Water B: Acetonitrile Gradient: 40% A to 85% A in 30 min Flow Rate: 1 mL/min Temperature: 25℃ Detection: UV 210 nm Sample: Validamycin Solutions for Low pH and High pH Applications Agela Technologies offers a family of stationary phases for applications to be run at extremely low or extremely high pH. These columns extend the capability of regular reverse phase HPLC columns with a typical pH range of 2-8, and provide more options for your applications and method development needs. Venusil ASB-C18 (pH: 0.8-7.5); Venusil ASB-C8 (pH: 1.0-7.5); Durashell RP (pH: 1.5-12.0) Low pH Stability of ASB-C18 Column: Venusil ASB-C18, 4.6 ×150 mm, 5 μm Sample: Naphthol Aging: 40℃, TFA in 80% methanol (pH=1.0), 400 hours Mobile phase:TFA in 80% methanol (pH=1.5) Flow rate: Injection: 1.0 mL/min 5 μL Temperature: 30℃ High pH Stability of Durashell RP Column: Flow rate: Durashell RP ; 4.6 × 150 mm 1.5 mL /min, 50% ACN/50% 0.05M Ammonia (pH=9.0) Sample: Doxepin, nortriptyline, amitriptyline, trimipramine , Temperature: 35℃ Solutions for LC-MS Agela Technologies provides columns that can meet the needs of LC-MS applications. The most popular LC-MS columns from Agela include: ●Unisol C18 (versatile) ●Venusil ASB-C18 and ASB-C8 (extremely low bleed and long lifetime at low pH) ●Unisol Amide (for extremely polar compounds) Benefits: ●Low bleed and symmetric peak shape→ Sensitivity ●High retention for polar compounds → Sensitivity, versatility, and low ion suppression for bioanalytical analysis. ●Compatible with 100% water to 100% organic solvents → Simplified method development effort ●Stability → Long column life means a reduced cost for customers Pseudoephedrine in Plasma Mass system: API Qtrap 3200, Applied Biosystem Mass condition: Positive Ion Mode, MRM HPLC Column: Venusil ASB C18 Column 2.1mm×50mm (Part No.: VS950502-0) Sample: Sample prepared by SPE (Cleanert PCX 60mg/3mL; Part No.: CX0603) Mobile Phase: A: 1% Formic Acid in Water ;B: Methanol Gradient: 20%B to 95%B in 2 min, hold for 0.5 min, thenswitch to A:B (20:80) Flow Rate: 0.5 mL/min Temperature: 25℃ Analysis of 14 Kinds of Hormone Mass system: Agilent 1100 Series LC/MSD Trap HPLC Column: Venusil XBP C18 Column 2.1mm×150mm( Part No.: VX951502-0) Sample: Estriol, Adosterone, Estrone+Estradial, Testosterone, Dehydro-iso-androsterone Methyl- Testosterone, Epitestosterone, Medroxyprogestrone+Stanolone,Progesetrone, Androsterone, 5-pregen-3beta-20-one Mobile Phase: A: Water. ;B: MeOH Gradient: 40%B to 80%B in 24 min, then hold for 12 min. Flow Rate: 0.8 mL /min Temperature: 25℃ Oleic Acid in Plasma Mass system: API Qtrap 3200, Applied Biosystem Mass condition: Negative Ion Mode, MRM HPLC Column: Venusil ASB C18 Column 2.1mm×50mm( Part No.: VS950502-0) Sample: Sample prepared by SPE (Cleanert PEP 60mg/3mL;Part No.: PE0603) Mobile Phase: A: 13mmol/L ammonium acetate aq., B: Acetonitrile Gradient: 5%B to 95%B in 2 min, hold for 2 min., switch to A:B (95:5) then hold for 2 min. Flow Rate: 0.8 mL/min Temperature: 25℃ Solutions for Fast Analysis Agela Technologies provides two approaches for fast HPLC analyses with shorter run times and higher column efficiencies. ●Small particle size or fused-core technology: Venusil AQ-C18 (2.5μm) , HALO (2.7μm) ●Unique retention mechanism : Optimix C18/Amide Mobile Phase: A: NH4AC Buffer (Adjust pH 6.0) B: ACN Gradient: 10%B to 60%B in 20 min. Flow rate: 1.0 mL / min Sample: Teicoplanin+Impurity Temperature: 35℃, Separation by Optimix C18/Amide Mobile Phase:A: Water, B: Methanol Sample: Uracil, Toluene Flow rate: 1mL/min Detection: UV 254nm t0= 1.52 min Bring extremely polar and non-polar analytes closer to shorten the analysis time under isocratic conditions Column: Optimix C18/amide,5μm, 4.6*150mm Column: C18, 5μm, 4.6*150mm Mobile Phase: A : B = 50:50 Mobile Phase: A : B= 60 : 40 Solutions for Bio-molecules Agela Technologies offers a broad line of HPLC columns for Bio-molecules, including reverse phase, normal phase, ion-exchange, HILIC and size exclusion columns. All column packing materials are made of ultra pure silica, bonded with pure silanes to ensure the surface inertness. General guide for the column selection: 1. Small peptide: C18, C8, C4; 100Å or 150 Å 2. Large peptide and proteins: C8, C4, 300 Å; ion-exchange; HILIC; size exclusion 3. Mono- and oligo-saccharides: ion-exchange; NH2; HILIC 4. Polysaccharides: ion-exchange; size exclusion 5. Oligo-nuclei: ion-exchange; reverse phase 6. Nuclei acids: ion-exchange; size exclusion See the section of “ordering information by the type of stationary phase” for ordering or call our technical staff for helps in selecting the columns you need. Solutions for Preparative HPLC (See Purification Section for More Information) Agela Technologies offers a full line of preparative HPLC columns to meet a variety of application needs. Our preparative columns feature: 1. Great scalability 2. Excellent bed stability 3. High loading capacity 4. Broad solvent compatibility from Unisol C18, Unisol Amide and Venusil ASB-C18 (100% aqueous to 100% organic solvents) 5. Broad pH range (1-12) from Venusil Durashell 6. Unique selectivity from Unisol Amide and Venusil ASB-C18 Unisol-Amide: an unique phase from Agela Technologies that offers a good alternative selectivity to reverse phase columns and an excellent solution for purifying highly polar compounds. Durashell RP: a high pH tolerance enable the use of high pH mobile phase, which results in great improvement of peak shape and loadability of basic compounds. Solutions for SFC Agela Technologies offers a broad line of normal phase columns of different selectivity for SFC applications, including: Unisol Amide Venusil NH2 Venusil Silica Venusil CN Venusil Nitrophenyl They are all made of high purity silica materials and are packed using our robust and reproducible process to ensure the high efficiency and the extended lifetime. See the section of “Ordering Information by the Type of Stationary Phase” for ordering or call our technical staff for helps. Ordering Information by the Type of Stationary Phases Reverse Phase Columns Reverse Phase Columns for Small Molecules Analytical Columns, Particle Size: 5μm Dimension Promosil Promosil Promosil Venusil Venusil Venusil Venusil (mm) C18 C8 CN XBP Phenyl XBP C4 XBP C1 XBP CN General C18, General C8, 100Å, 320 100Å, 320 100Å, 320 100Å, 380 100Å, 380 100Å, 380 100Å, 380 m2/g; C%=10 m2/g; C%=10 m2/g, C%=5 m2/g, C%=12 m2/g, C%=7 m2/g; C%= 3 m2/g, C%=7 2.1×20 PM950202-0 PM850202-0 PM550202-0 VX650202-0 VX450202-0 VX150202-0 VC950202-0 2.1×30 PM950302-0 PM850302-0 PM550302-0 VX650302-0 VX450302-0 VX150302-0 VC950302-0 2.1×50 PM950502-0 PM850502-0 PM550502-0 VX650502-0 VX450502-0 VX150502-0 VC950502-0 2.1×100 PM951002-0 PM851002-0 PM551002-0 VX651002-0 VX451002-0 VX151002-0 VC951002-0 2.1×150 PM951505-0 PM851505-0 PM551505-0 VX651502-0 VX451502-0 VX151502-0 VC951502-0 3.0x30 PM950303-0 PM850303-0 PM550303-0 VX650303-0 VX450303-0 VX150303-0 VC950303-0 3.0x50 PM950503-0 PM850503-0 PM550503-0 VX650503-0 VX450503-0 VX150503-0 VC950503-0 3.0x100 PM951003-0 PM851003-0 PM551003-0 VX651003-0 VX451003-0 VX151003-0 VC951003-0 3.0x150 PM951503-0 PM851503-0 PM551503-0 VX651503-0 VX451503-0 VX151503-0 VC951503-0 4.6×50 PM950505-0 PM850505-0 PM550505-0 VX650505-0 VX450505-0 VX150505-0 VC950505-0 4.6×100 PM951005-0 PM851005-0 PM551005-0 VX651005-0 VX451005-0 VX151005-0 VC951005-0 4.6×150 PM951505-0 PM851505-0 PM551505-0 VX651505-0 VX451505-0 VX151505-0 VC951505-0 4.6×200 PM952005-0 PM852005-0 PM552005-0 VX652005-0 VX452005-0 VX152005-0 VC952005-0 4.6×250 PM952505-0 PM852505-0 PM552505-0 VX652505-0 VX452505-0 VX152505-0 VC952505-0 4.6×10 PM950105-0 PM850105-0 PM550105-0 VX650105-0 VX450105-0 VX150105-0 VC950105-0 ID: 2.1, 3.0, 4.6 CH-100 CH-100 CH-100 CH-100 CH-100 CH-100 CH-100 Column Type Dimension Particle Venusil XBP C18 Venusil XBP (mm) Size (μm) (2) C18 (L) ultra surface inertness and reproducibility; balanced retention; 100Å, 380 m2/g, C%=19 same as XBP C18 with larger pore size; 150Å, 200 m2/g; C%=15 Analytical 2.1×30 5 VX950302-2 VX950302-L Analytical 2.1×50 5 VX950502-2 VX950502-L Analytical 2.1×100 5 VX951002-2 VX951002-L Analytical 2.1×150 5 VX951502-2 VX951502-L Analytical 3.0x30 5 VX950303-2 VX950303-L Analytical 3.0x50 5 VX950503-2 VX950503-L Analytical 3.0x100 5 VX951003-2 VX951003-L Analytical 3.0x150 5 VX951503-2 VX951503-L Analytical 4.6×50 5 VX950505-2 VX950505-L Analytical 4.6×100 5 VX951005-2 VX951005-L Analytical 4.6×150 5 VX951505-2 VX951505-L Analytical 4.6×200 5 VX952005-2 VX952005-L Analytical 4.6×250 5 VX952505-2 VX952505-L ard Cartridge 4.6×10, 4/pk 5 VX950105-2 VX950105-L rtridge Holder 20x10 CH-200 CH-200 Dimension Particle Venusil Venusil Venusil AQ (mm) Size (μm) ASB C18 ASB C8 C18 extreme low Unisol C18 for high aqueous universal RP; pH tolerance C8 for low pH applications; compatible (0.8-7.5), low and low bleed; compatible with with 100% 2 bleed; 150 Å, 150 Å, 200m /g, 100% water; water; 100Å, 200m2/g; C%=7 100Å, 380 m2/g, 410 m2/g, C%=18 C%=17 C%=12 Durashell Venusil Venusil RP XBP-C18 XBP-C8 high pH tolerance (1.5-12); 150Å, 240 m2/g, C%=15 highest general RP; hydrophobicity; 2 100Å, 380 100Å, 380m /g, m2/g; C%= C%=22 14 2.1×30 5 VS950302-0 VS850302-0 VA950302-0 UO950302-0 DS950302-0 VX950302-0 VX850302-0 2.1×50 5 VS950502-0 VS850502-0 VA950502-0 UO950502-0 DS950502-0 VX950502-0 VX850502-0 2.1×100 5 VS951002-0 VS851002-0 VA951002-0 UO951002-0 DS951002-0 VX951002-0 VX851002-0 2.1×150 5 VS951502-0 VS851502-0 VA951502-0 UO951502-0 DS951502-0 VX951502-0 VX851502-0 3.0x30 5 VS950303-0 VS850303-0 VA950303-0 UO950303-0 DS950303-0 VX950303-0 VX850303-0 3.0x50 5 VS950503-0 VS850503-0 VA950503-0 UO950503-0 DS950503-0 VX950503-0 VX850503-0 3.0x100 5 VS951003-0 VS851003-0 VA951003-0 UO951003-0 DS951003-0 VX951003-0 VX851003-0 3.0x150 5 VS951503-0 VS851503-0 VA951503-0 UO951503-0 DS951503-0 VX951503-0 VX851503-0 4.6×50 5 VS950505-0 VS850505-0 VA950505-0 UO950505-0 DS950505-0 VX950505-0 VX850505-0 4.6×100 5 VS951005-0 VS851005-0 VA951005-0 UO951005-0 DS951005-0 VX951005-0 VX851005-0 4.6×150 5 VS951505-0 VS851505-0 VA951505-0 UO951505-0 DS951505-0 VX951505-0 VX851505-0 4.6×200 5 VS952005-0 VS852005-0 VA952005-0 UO952005-1 DS952005-0 VX952005-0 VX852005-0 4.6×250 5 VS952505-0 VS852505-0 VA952505-0 UO952505-0 DS952505-0 VX952505-0 VX852505-0 G 4.6×10, 4/pk 5 VS950105-0 VS850105-0 VA950105-0 UO950105-0 DS950105-0 VX950105-0 VX850105-0 2.1×20 3 VS930202-0 VS830202-0 VA930202-0 UO930202-0 DS930202-0 VX930202-0 VX830202-0 2.1×30 3 VS930302-0 VS830302-0 VA930302-0 UO930302-0 DS930302-0 VX930302-0 VX830302-0 2.1×50 3 VS930502-0 VS830502-0 VA930502-0 UO930502-0 DS930502-0 VX930502-0 VX830502-0 2.1×100 3 VS931002-0 VS831002-0 VA931002-0 UO931002-0 DS931002-0 VX931002-0 VX831002-0 2.1×150 3 VS931502-0 VS831502-0 VA931502-0 UO931502-0 DS931502-0 VX931502-0 VX831502-0 3.0x30 3 VS930303-0 VS830303-0 VA930303-0 UO930303-0 DS930303-0 VX930303-0 VX830303-0 3.0x50 3 VS930503-0 VS830503-0 VA930503-0 UO930503-0 DS930503-0 VX930503-0 VX830503-0 3.0x100 3 VS931003-0 VS831003-0 VA931003-0 UO931003-0 DS931003-0 VX931003-0 VX831003-0 3.0x150 3 VS931503-0 VS831503-0 VA931503-0 UO931503-0 DS931503-0 VX931503-0 VX831503-0 G 3.0×10 3 VS930103-0 VS830103-0 VA930103-0 UO930103-0 DS930103-0 VX930103-0 VX830103-0 4.6×50 3 VS930505-0 VS830502-0 VA930505-0 UO930505-0 DS930505-0 VX930505-0 VX830502-0 4.6×100 3 VS931005-0 VS831002-0 VA930505-0 UO931005-0 DS931005-0 VX931005-0 VX831002-0 4.6×150 3 VS931505-0 VS831505-0 VA931505-0 UO931505-0 DS931505-0 VX931505-0 VX831505-0 G4.6×10 3 VS930105-0 VS830105-0 VA930105-0 UO930105-0 DS930105-0 VX930105-0 VX830105-0 CH-100 CH-100 CH-100 CH-100 CH-100 CH-100 GCH 2.1, 3.0, 4.6 10×150 5 VS951510-0 VA951510-0 UO951510-0 DS951510-0 VX951510-0 VX851510-0 10×250 5 VS952510-0 VA952510-0 UO952510-0 DS952510-0 VX952510-0 VX852510-0 20×50 5 VS950520-0 VA950520-0 UO950520-0 DS950520-0 VX950520-0 VX850520-0 20×150 5 VS951520-0 VA951520-0 UO951520-0 DS951520-0 VX951520-0 VX851520-0 20×250 5 VS952520-0 VA952520-0 UO952520-0 DS952520-0 VX952520-0 VX852520-0 30×100 5 VS951030-0 VA951030-0 UO951030-0 DS951030-0 VX951030-0 VX851030-0 30×150 5 VS951530-0 VA951530-0 UO951530-0 DS951530-0 VX951530-0 VX851530-0 30×250 5 VS952530-0 VA952530-0 UO952530-0 DS952530-0 VX952530-0 VX852530-0 G 20×10 5 VS950120-0 VA950120-0 UO950120-0 DS950120-0 VX950120-0 VX850120-0 10×150 10 VS901510-0 UO901510-0 DS901510-0 VX901510-0 VX801510-0 10×250 10 VS902510-0 UO902510-0 DS902510-0 VX902510-0 VX802510-0 20×50 10 VS900520-0 UO900520-0 DS900520-0 VX900520-0 VX800520-0 20×150 10 VS901520-0 UO901520-0 DS901520-0 VX901520-0 VX801520-0 20×250 10 VS902520-0 UO902520-0 DS902520-0 VX902520-0 VX802520-0 30×100 10 VS901030-0 UO901030-0 DS901030-0 VX901030-0 VX801030-0 30×150 10 VS901530-0 UO901530-0 DS901530-0 VX901530-0 VX801530-0 30×250 10 VS902530-0 UO902530-0 DS902530-0 VX902530-0 VX802530-0 50×150 10 VS901550-0 UO901550-0 DS901550-0 VX901550-0 VX801550-0 50×250 10 VS902550-0 UO902550-0 DS902550-0 VX902550-0 VX802550-0 G 20×10 10 VS90120-0 UO900120-0 DS900120-0 VX900120-0 VX800120-0 CH-200 CH-200 CH-200 CH-200 GCH 20x10 CH-200 CH-200 CH-200 G=Guard Cartridge; GCH= Guard Cartridge Holder Reverse Phase Columns for Large Molecules 2 Particle Size: 5μm; Pore Size: 300Å; Surface Area: 45 m /g Column Dimension Venusil XBP Venusil Venusil Venusil Type (mm) Phenyl XBP C4 XBP C1 XBP CN Analytical 2.1×30 VX650302-T VX450302-T VX150302-T VC950302-T Analytical 2.1×50 VX650502-T VX450502-T VX150502-T VC950502-T Analytical 2.1×100 VX651002-T VX451002-T VX151002-T VC951002-T Analytical 2.1×150 VX651502-T VX451502-T VX151502-T VC951502-T Analytical 3.0x30 VX650303-T VX450303-T VX150303-T VC950303-T Analytical 3.0x50 VX650503-T VX450503-T VX150503-T VC950503-T Analytical 3.0x100 VX651003-T VX451003-T VX151003-T VC951003-T Analytical 3.0x150 VX651503-T VX451503-T VX151503-T VC951503-T Analytical 4.6×50 VX650505-T VX450505-T VX150505-T VC950505-T Analytical 4.6×100 VX651005-T VX451005-T VX151005-T VC951005-T Analytical 4.6×150 VX651505-T VX451505-T VX151505-T VC951505-T Analytical 4.6×200 VX652005-T VX452005-T VX152005-T VC952005-T Analytical 4.6×250 VX652505-T VX452505-T VX152505-T VC952505-T Guard 4.6×10, Cartridge 4/pk VX650105-T VX450105-T VX150105-T VC950105-T Cartridge 2.1, 3.0, Holder 4.6 CH-100 CH-100 CH-100 CH-100 Semi-prep 10×150 VX651510-T VX451510-T VX151510-T VC951510-T Semi-prep 10×250 VX652510-T VX452510-T VX152510-T VC952510-T Semi-prep 20×50 VX650520-T VX450520-T VX150520-T VC950520-T Semi-prep 20×150 VX651520-T VX451520-T VX151520-T VC951520-T Semi-prep 20×250 VX652520-T VX452520-T VX152520-T VC952520-T 20×10 VX650120-T VX450120-T VX150120-T VC950120-T 20×10 CH-200 CH-200 CH-200 CH-200 Guard Cartridge Cartridge Holder 2 Particle Size: 5μm; Pore Size: 300Å; Surface Area: 45 m /g Type Dimension Venusil Venusil Venusil Venusil (mm) ASB C18 ASB C8 XBP C18 XBP C8 highest General hydrophobicity RP extreme low pH C8 for low tolerance pH and (0.8-7.5), low bleed low bleed Analytical 2.1×30 VS950302-T VS850302-T VX950302-T VX850302-T Analytical 2.1×50 VS950502-T VS850502-T VX950502-T VX850502-T Analytical 2.1×100 VS951002-T VS851002-T VX951002-T VX851002-T Analytical 2.1×150 VS951502-T VS851502-T VX951502-T VX851502-T Analytical 3.0x30 VS950303-T VS850303-T VX950303-T VX850303-T Analytical 3.0x50 VS950503-T VS850503-T VX950503-T VX850503-T Analytical 3.0x100 VS951003-T VS851003-T VX951003-T VX851003-T Analytical 3.0x150 VS951503-T VS851503-T VX951503-T VX851503-T Analytical 4.6×50 VS950505-T VS850505-T VX950505-T VX850505-T Analytical 4.6×100 VS951005-T VS851005-T VX951005-T VX851005-T Analytical 4.6×150 VS951505-T VS851505-T VX951505-T VX851505-T Analytical 4.6×200 VS952005-T VS852005-T VX952005-T VX852005-T Analytical 4.6×250 VS952505-T VS852505-T VX952505-T VX852505-T 4.6×10, 4/pk VS950105-T VS850105-T VX950105-T VX850105-T CH-100 CH-100 CH-100 CH-100 Guard Cartridge Cartridge ID: 2.1, 3.0, Holder 4.6 Semi-Prep 10×150 VS951510-T VS851510-T VX951510-T VX851510-T Semi-Prep 10×250 VS952510-T VS852510-T VX952510-T VX852510-T Semi-Prep 20×50 VS950520-T VS850520-T VX950520-T VX850520-T Semi-Prep 20×150 VS951520-T VS851520-T VX951520-T VX851520-T Semi-Prep 20×250 VS952520-T VS852520-T VX952520-T VX852520-T 20×10 VS950120-T VS850120-T VX950120-T VX850120-T 20×10 CH-200 CH-200 CH-200 CH-200 Guard Cartridge Cartridge Holder Normal Phase Columns Normal Phase Columns for Small Molecules Particle Size: 5μm Type Dimension (mm) Particle Unisol Venusil Venusil Size Amide Silica XBP-NH2(HILIC (μm) (HILIC) (HILIC II) III) unique selectivity; 100Å, 410 m2/g, ultra pure ;100Å, 2 380m /g, ultra pure: 100 Å,380m2/g; Venusil Venusil XBP-Diol XBP CN ultra pure: ultra 100Å, 380 pure:100Å,380 2 m /g m2/g Analytical 2.1×30 5 VH950302-0 VSi950302-0 VN850302-0 VC950302-0 VD950302-0 Analytical 2.1×50 5 VH950502-0 VSi950502-0 VN850502-0 VC950502-0 VD950502-0 Analytical 2.1×100 5 VH951002-0 VSi951002-0 VN851002-0 VC951002-0 VD951002-0 Analytical 2.1×150 5 VH951502-0 VSi951502-0 VN851502-0 VC951502-0 VD951502-0 Analytical 3.0x30 5 VH950303-0 VSi950303-0 VN850303-0 VC950303-0 VD950303-0 Analytical 3.0x50 5 VH950503-0 VSi950503-0 VN850503-0 VC950503-0 VD950503-0 Analytical 3.0x100 5 VH951003-0 VSi951003-0 VN851003-0 VC951003-0 VD951003-0 Analytical 3.0x150 5 VH951503-0 VSi951503-0 VN851503-0 VC951503-0 VD951503-0 Analytical 4.6×50 5 VH950505-0 VSi950505-0 VN850505-0 VC950505-0 VD950505-0 Analytical 4.6×100 5 VH951005-0 VSi951005-0 VN851005-0 VC951005-0 VD951005-0 Analytical 4.6×150 5 VH951505-0 VSi951505-0 VN851505-0 VC951505-0 VD951505-0 Analytical 4.6×200 5 VH952005-0 VSi952005-0 VN852005-0 VC952005-0 VD952005-0 Analytical 4.6×250 5 VH952505-0 VSi952505-0 VN852505-0 VC952505-0 VD952505-0 5 VH950105-0 VSi950105-0 VN850105-0 VC950105-0 VD950105-0 CH-100 CH-100 CH-100 CH-100 CH-100 Guard cartridge, 4.6×10 , 4/pk GCH 2.1,3.0,4.6 Semi-preparative 10×150 5 VH951510-0 VSi951510-0 VN851510-0 VC951510-0 Semi-preparative 10×250 5 VH952510-0 VSi952510-0 VN852510-0 VC952510-0 Preparative 20×50 5 VH950520-0 VSi950520-0 VN850520-0 VC950520-0 Preparative 20×150 5 VH951520-0 VSi951520-0 VN851520-0 VC951520-0 Preparative 20×250 5 VH952520-0 VSi952520-0 VN852520-0 VC952520-0 Preparative 30×100 5 VH951030-0 VSi951030-0 VN851030-0 VC951030-0 Preparative 30×150 5 VH951530-0 VSi951530-0 VN851530-0 VC951530-0 Preparative 30×250 5 VH952530-0 VSi952530-0 VN852530-0 VC952530-0 Guard Cartridge 20×10 VH950220-0 VSi950220-0 VN850220-0 VC950220-0 Semi-preparative 10×150 10 VH901510-0 VSi901510-0 VN801510-0 VC901510-0 Semi-preparative 10×250 10 VH902510-0 VSi902510-0 VN802510-0 VC902510-0 Preparative 20×50 10 VH900520-0 VSi900520-0 VN800520-0 VC900520-0 Preparative 20×150 10 VH901520-0 VSi901520-0 VN801520-0 VC901520-0 Preparative 20×250 10 VH902520-0 VSi902520-0 VN802520-0 VC902520-0 Preparative 30×100 10 VH901030-0 VSi901030-0 VN801030-0 VC901030-0 Preparative 30×150 10 VH901530-0 VSi901530-0 VN801530-0 VC901530-0 Preparative 30×250 10 VH902530-0 VSi902530-0 VN802530-0 VC902530-0 Preparative 50×150 10 VH901550-0 VSi901550-0 VN801550-0 VC901550-0 Preparative 50×250 10 VH902550-0 VSi902550-0 VN802550-0 VC902550-0 Guard Cartridge 20×10 10 VH900120-0 VSi900120-0 VN800120-0 VC900120-0 GCH 2.1,3.0,4.6 CH-200 CH-200 CH-200 CH-200 GCH=Guard Cartridge Holder High Purity; Pore Size: 100 Å; Surface Aera: 320m2/g Type Dimension (mm) Particle Size (μm) Promosil -CN Promosil-Silica Promosil -NH2 Analytical 2.1×30 5 PM550302-0 PM050302-0 PM750302-0 Analytical 2.1×50 5 PM550502-0 PM050502-0 PM750502-0 Analytical 2.1×100 5 PM551002-0 PM051002-0 PM751002-0 Analytical 2.1×150 5 PM551502-0 PM051502-0 PM751505-0 Analytical 3.0x30 5 PM550303-0 PM050303-0 PM750303-0 Analytical 3.0x50 5 PM550503-0 PM050503-0 PM750503-0 Analytical 3.0x100 5 PM551003-0 PM051003-0 PM751003-0 Analytical 3.0x150 5 PM551503-0 PM051503-0 PM751503-0 Analytical 4.6×50 5 PM550505-0 PM050505-0 PM750505-0 Analytical 4.6×100 5 PM551005-0 PM051005-0 PM751005-0 Analytical 4.6×150 5 PM551505-0 PM051505-0 PM751505-0 Analytical 4.6×200 5 PM552005-0 PM052005-0 PM752005-0 Analytical 4.6×250 5 PM552505-0 PM052505-0 PM752505-0 Guard 4.6×10 , cartridge, 4/pk 5 PM550105-0 PM050105-0 PM750105-0 CH-100 CH-100 CH-100 Guard cartridge Holder 2.1,3.0,4.6 10×150 5 PM051510-0 10×250 5 PM052510-0 Preparative 20×50 5 PM050520-0 Preparative 20×150 5 PM051520-0 Preparative 20×250 5 PM052520-0 Preparative 30×100 5 PM051030-0 Preparative 30×150 5 PM051530-0 Preparative 30×250 5 PM052530-0 20×20 5 PM050220-0 Semi-preparative Semi-preparative Guard Cartridge Normal Phase Columns for Large Molecules Ultra Pure Silica; Pore Size:300 Å; Surface Area:45m2/g Type Dimension Particle Venusil Venusil Venusil Unisol Amide Venusil (mm) Size (μm) XBP NH2 XBP Diol XBP CN (HILIC) XBP Silica Analytical 2.1×30 5 VN850302-T VD950302-T VC950302-T VH950302-T VSi950302-T Analytical 2.1×50 5 VN850502-T VD950502-T VC950502-T VH950502-T VSi950502-T Analytical 2.1×100 5 VN851002-T VD951002-T VC951002-T VH951002-T VSi951002-T Analytical 2.1×150 5 VN851502-T VD951502-T VC951502-T VH951502-T VSi951502-T Analytical 3.0x30 5 VN850303-T VD950303-T VC950303-T VH950303-T VSi950303-T Analytical 3.0x50 5 VN850503-T VD950503-T VC950503-T VH950503-T VSi950503-T Analytical 3.0x100 5 VN851003-T VD951003-T VC951003-T VH951003-T VSi951003-T Analytical 3.0x150 5 VN851503-T VD951503-T VC951503-T VH951503-T VSi951503-T Analytical 4.6×50 5 VN850505-T VD950505-T VC950505-T VH950505-T VSi950505-T Analytical 4.6×100 5 VN851005-T VD951005-T VC951005-T VH951005-T VSi951005-T Analytical 4.6×150 5 VN851505-T VD951505-T VC951505-T VH951505-T VSi951505-T Analytical 4.6×200 5 VN852005-T VD952005-T VC952005-T VH952005-T VSi952005-T Analytical 4.6×250 5 VN852505-T VD952505-T VC952505-T VH952505-T VSi952505-T Guard Cartridge 4.6×10, 4/pk 5 VN850105-T VD950105-T VC950105-T VH950105-T VSi950105-T CH-100 CH-100 CH-100 CH-100 CH-100 ID: 2.1, 3.0, GCH 4.6 Semi-preparative 10×150 5 VN851510-T VC951510-T VSi951510-T Semi-preparative 10×250 5 VN852510-T VC952510-T VSi952510-T Preparative 20×50 5 VN850520-T VC950520-T VSi950520-T Preparative 20×150 5 VN851520-T VC951520-T VSi951520-T Preparative 20×250 5 VN852520-T VC952520-T VSi952520-T Preparative 30×100 5 VN851030-T VC951030-T VSi951030-T Preparative 30×150 5 VN851530-T VC951530-T VSi951530-T Preparative 30×250 5 VN852530-T VC952530-T VSi952530-T Guard Cartridge 20×10 5 VN850120-T VC950120-T VSi950120-T GCH 20x10 CH-200 CH-200 CH-200 GCH=Guard cartridge Holder Ion-exchange Columns Surface Aera: 200m2/g,Pore Size: 150Å Dimension Particle Venusil Venusil (mm) Size (μm) SAX SCX Analytical 4.6×100 5 VSa951005-0 VSc951005-0 Analytical 4.6×150 5 VSa951505-0 VSc951505-0 Analytical 4.6×250 5 VSa952505-0 VSc952505-0 4.6×10 4/pk 5 VSa950105-0 VSc950105-0 Dimension Particle Venusil Venusil (mm) Size (μm) SAX SCX Analytical 4.6×100 5 VSa951005-T VSc951005-T Analytical 4.6×150 5 VSa951505-T VSc951505-T Analytical 4.6×250 5 VSa952505-T VSc952505-T 4.6×10 4/pk 5 VSa950105-T VSc950105-T Type Guard cartridge Surface Aera: 50m2/g,Pore Size: 300Å Type Guard cartridge Mixed Phase Columns Type Dimension Particle Optimix Optimix Optimix Optimix (mm) Size(μm) C18/C8 C18/amide C18/phenyl C18/CN Analytical 2.1×30 5 OP950302-OC OP950302-AM OP950302-PH OP950302-CN Analytical 2.1×50 5 OP950502-OC OP950502-AM OP950502-PH OP950502-CN Analytical 2.1×100 5 OP951002-OC OP951002-AM OP951002-PH OP951002-CN Analytical 2.1×150 5 OP951502-OC OP951502-AM OP951502-PH OP951502-CN Analytical 4.6×50 5 OP950505-OC OP950505-AM OP950505-PH OP950505-CN Analytical 4.6×100 5 OP951005-OC OP951005-AM OP951005-PH OP951005-CN Analytical 4.6×150 5 OP951505-OC OP951505-AM OP951505-PH OP951505-CN Analytical 4.6×200 5 OP952005-OC OP952005-AM OP952005-PH OP952005-CN Analytical 4.6×250 5 OP952505-OC OP952505-AM OP952505-PH OP952505-CN 4.6×10 5 OP950105-OC OP950105-AM OP950105-PH OP950105-CN Fast analysis 2.1×30 3 OP930302-OC OP930302-AM OP930302-PH OP930302-CN Fast analysis 2.1×50 3 OP930502-OC OP930502-AM OP930502-PH OP930502-CN Fast analysis 2.1×100 3 OP931002-OC OP931002-AM OP931002-PH OP931002-CN Fast analysis 2.1×150 3 OP931502-OC OP931502-AM OP931502-PH OP931502-CN Fast analysis 4.6×50 3 OP930505-OC OP930505-AM OP930505-PH OP930505-CN Fast analysis 4.6×100 3 OP931005-OC OP931005-AM OP931005-PH OP931005-CN Fast analysis 4.6×150 3 OP931505-OC OP931505-AM OP931505-PH OP931505-CN 4.6×10 3 OP930105-OC OP930105-AM OP930105-PH OP930105-CN Guard cartridge Guard cartridge Type Dimension Particle Optimix Optimix Optimix (mm) Size(μm) C18/SCX C18/SAX C18/Nitrophenyl Analytical 2.1×30 5 OP950302-SC OP950302-SA OP950302-NP Analytical 2.1×50 5 OP950502-SC OP950502-SA OP950502-NP Analytical 2.1×100 5 OP951002-SC OP951002-SA OP951002-NP Analytical 2.1×150 5 OP951502-SC OP951502-SA OP951502-NP Analytical 4.6×50 5 OP950505-SC OP950505-SA OP950505-NP Analytical 4.6×100 5 OP951005-SC OP951005-SA OP951005-NP Analytical 4.6×150 5 OP951505-SC OP951505-SA OP951505-NP Analytical 4.6×200 5 OP952005-SC OP952005-SA OP952005-NP Analytical 4.6×250 5 OP952505-SC OP952505-SA OP952505-NP 4.6×10 5 OP950105-SC OP950105-SA OP950105-NP Fast analysis 2.1×30 3 OP930302-SC OP930302-SA OP930302-NP Fast analysis 2.1×50 3 OP930502-SC OP930502-SA OP930502-NP Fast analysis 2.1×100 3 OP931002-SC OP931002-SA OP931002-NP Fast analysis 2.1×150 3 OP931502-SC OP931502-SA OP931502-NP Fast analysis 4.6×50 3 OP930505-SC OP930505-SA OP930505-NP Fast analysis 4.6×100 3 OP931005-SC OP931005-SA OP931005-NP Fast analysis 4.6×150 3 OP931505-SC OP931505-SA OP931505-NP 4.6×10 3 OP930105-SC OP930105-SA OP930105-NP Guard cartridge Guard cartridge Size Exclusion Columns (Silica Based) Type Dimension Particle (mm) Size (μm) GF GF 300 GF amide GFamide-300 ultra pure,high ultra pure,high ultra pure,high ultra pure,high porosity;bonded porosity;bonded porosity;bonded with porosity;bonded with 120Å, 300Å, amide 120Å, amide 300Å, Analytical 4.6x 150 5 GF151505-0 GF351505-0 GF151505-A GF301505-A Analytical 4.6x 250 5 GF152505-0 GF352505-0 GF152505-A GF302505-A Analytical 4.6x 150 10 GF101505-0 GF301505-0 GF101505-A GF301505-A Analytical 4.6x 250 10 GF102505-0 GF302505-0 GF102505-A GF302505-A Semi-prep. 10x150 5 GF151510-0 GF351510-0 GF151510-A GF301510-A Semi-prep. 10x250 5 GF152510-0 GF352510-0 GF152510-A GF302510-A Semi-prep. 10x150 10 GF101510-0 GF301510-0 GF101510-A GF301510-A Semi-prep. 10x250 10 GF102510-0 GF302510-0 GF102510-A GF302510-A Polymer Phase Columns RPC-Analytical Prepacked Columns Dimension Particle (mm) Size (μm) AKF-RP-M-154607 4.6×150 7 AKF-RP-M-154610 4.6×150 10 AKF-RP-M-154620 4.6×150 20 AKF-RP-H-254605 4.6×250 5 AKF-RP-H-254607 4.6×250 7 AKF-RP-H-254610 4.6×250 10 AKF-RP-H-254620 4.6×250 20 Matrix RPC-Preparative Prepacked Columns Matrix Dimension (mm) Particle Size (μm) AKF-RP-M-052007 20×50 5 AKF-RP-M-102007 20×100 5 AKF-RP-M-251007 10×250 7 AKF-RP-M-252007 20×250 7 AKF-RP-M-151010 10×150 10 AKF-RP-M-152010 20×150 10 AKF-RP-H-151010 10×150 10 AKF-RP-H-152010 20×150 10 AKF-RP-M-251010 10×250 10 AKF-RP-M-252010 20×250 10 AKF-RP-H-251010 10×250 10 AKF-RP-H-252010 20×250 10 AKF-RP-H-152020 20×150 20 AKF-RP-H-252020 20×250 20 AKF-RP-H-105020 50×100 20 AKF-RP-H-255020 50×250 20 AKF-RP-H-2510020 100×250 20 Hydrophobic Interaction Chromatography Columns Dimension Particle Size (mm) (μm) AKF-PHEMM-154607 4.6×150 7 AKF-PHEMM-154610 4.6×150 10 AKF-PHEMM-154620 4.6×150 20 AKF-PHEMH-254607 4.6×250 7 AKF-PHEMH-254610 4.6×250 10 AKF-PHEMH-254620 4.6×250 20 AKF-PHEMH-036410 6.4×30 10 AKF-C4-MM-154607 4.6×150 7 AKF-C4-MM-154610 4.6×150 10 AKF-C4-MM-154620 4.6×150 20 AKF-C4-MH-254607 4.6×250 7 AKF-C4-MH-254610 4.6×250 10 AKF-C4-MH-254620 4.6×250 20 AKF-C4-MH-036410 6.4×30 10 AKF-C8-MM-154607 4.6×150 7 AKF-C8-MM-154610 4.6×150 10 AKF-C8-MM-154620 4.6×150 20 AKF-C8-MH-254607 4.6×250 7 AKF-C8-MH-254610 4.6×250 10 AKF-C8-MH-254620 4.6×250 20 AKF-C8-MH-036410 6.4×30 10 AKF-ETHMM-154607 4.6×150 7 AKF-ETHMM-154610 4.6×150 10 AKF-ETHMM-154620 4.6×150 20 AKF-ETHMH-254607 4.6×250 7 AKF-ETHMH-254610 4.6×250 10 AKF-ETHMH-254620 4.6×250 20 AKF-ETHMH-036410 6.4×30 10 Matrix Ion Exchange Chromatography Columns (strong cation) Matrix Dimension Particle Size (mm) (μm) AKF-CISLM-050207 2.0×50 5 AKF-CISLM-150207 2.0×150 5 AKF-CISLM-154607 4.6×150 7 AKF-CISLM-154610 4.6×150 10 AKF-CISLM-154620 4.6×150 20 AKF-CISLH-154607 4.6×150 7 AKF-CISLH-154610 4.6×150 10 AKF-CISLH-154620 4.6×150 20 AKF-CISLM-254610 4.6×250 10 AKF-CISLH-254610 4.6×250 10 AKF-CISLH-251010 10×250 10 AKF-CISLH-101010 10×100 10 Ion Exchange Chromatography Columns (Weak cation) Dimension Particle Size (mm) (μm) AKF-CLV-050207 2.0×50 5 AKF-CLV-150207 2.0×150 5 AKF-CLV-154607 4.6×150 7 AKF-CLV-154610 4.6×150 10 AKF-CLV-154620 4.6×150 20 AKF-CHV-154607 4.6×150 7 AKF-CHV-154610 4.6×150 10 AKF-CHV-154620 4.6×150 20 AKF-CLV-254610 4.6×250 10 AKF-CHV-254610 4.6×250 10 AKF-CHV-251010 10×250 10 AKF-CHV-101010 10×100 10 Matrix Ion Exchange Chromatography Columns (Strong Anion) Dimension Particle (mm) Size (μm) AKF-QLV-050207 2.0×50 5 AKF-QLV-150207 2.0×150 5 AKF-QLV-154607 4.6×150 7 AKF-QLV-154610 4.6×150 10 AKF-QLV-154620 4.6×150 20 AKF-QHV-154607 4.6×150 7 AKF-QHV-154610 4.6×150 10 AKF-QHV-154620 4.6×150 20 AKF-QLV-254610 4.6×250 10 AKF-QHV-254610 4.6×250 10 AKF-QHV-251010 10×250 10 AKF-QHV-101010 10×100 10 Matrix Ion Exchange Chromatography Columns (Weak Anion) Matrix Dimension Particle (mm) Size (μm) AKF-DEAL-050207 2.0×50 5 AKF-DEAL-150207 2.0×150 5 AKF-DEAL-154607 4.6×150 7 AKF-DEAL-154610 4.6×150 10 AKF-DEAL-154620 4.6×150 20 AKF-DEAH-154607 4.6×150 7 AKF-DEAH-154610 4.6×150 10 AKF-DEAH-154620 4.6×150 20 AKF-DEAL-254610 4.6×250 10 AKF-DEAH-254610 4.6×250 10 AKF-DEAH-251010 10×250 10 AKF-DEAH-101010 10×100 10 HPLC Column Selection Guide Column Selection Parameters Stationary Phases z Reverse Phase [C18 (XBP, AQ, ASB), C8 (XBP, ASB), C4 , Phenyl ]: most HPLC analytical and preparative separations; use shorter chain if the retention is too high on C18 columns;use shorter chain (C8, C4) for proteins and larger peptides. z Normal Phase [Silica, Amino, SAX, SCX]: for those not applicable on reverse phase; polysaccharides (amino), ion-exchange chromatography, some preparative needs. z Bi-mode [Cyano, Venusil HILIC]: can be used in both reverse and normal phase modes, alternative selectivity to hydrocarbon-based reverse phases, inert and better reproducibility than silica columns. Particle Size z 3 μm: fast analysis, high throughput analytical applications, micro/nano HPLC z 5 μm: analytical and semi-preparative separation z 10 μm: preparative separation Pore Size z Narrow pore (100-150 Å): MW <3000 z Large pore (300-500 Å): 3000< MW <50000 z Mega pore (1000 Å): MW >50000 Column Length z Short (30 mm, 50 mm): high throughput analysis and purification, pre-separation z Regular (100 mm, 150 mm, 250 mm): more complex sample, larger injection volume Column Diameter z Capillary (0.5 mm, 1.0 mm): LC-MS, micro-HPLC, very small sample volume z Analytical (2.1 mm, 4.6 mm, 10 mm): standard HPLC, analytical and mini-prep z Preparative (21 mm, 30 mm, 50 mm): preparative HPLC Basic Considerations in Choosing HPLC Columns Analyte z Molecular Weight – small molecule (<3000), narrow pore; medium molecule(3000- 50000), large pore; large molecule(>50000), mega pore. z Solubility in aqueous solutions – very hydrophilic, use AQ-C18, ASB-C18 or Venusil HILIC; very hydrophobic, use shorter chain phases (C8, C4, Phenyl, CN); in between, use AQ-C18, ASP-C18, XPB-C18 or Phenyl . z Difference between the compounds to be separated – by polarity, use AQ C18, ASB-C18, cyano, HILIC; by shape or regio-isomer, use XBP-C18, phenyl. Mobile Phase • Solution solvent: 97-100% aqueous solution, AQ-C18 or ASB-C18; normal phase mode with aqueous mobile z phase, Venusil HILIC • pH: pH < 2, C18 phases; pH > 9, XBP-C18; pH= 2-9, most phases; (check the pH range for each column z before use!) • Salt concentration: high salt concentration >0.1 M (should be avoided if possible), XBP-C18, SCX, SAX. Sample z Analyte mass/concentration: high mass load, larger diameter column (>10 for preparative). z Sample volume: small volume, small diameter; large volume, large diameter and length. z Sample complexity: simple separation, short column; complex separation, long column. Instrument and Application z Traditional HPLC analysis: 3μm, 5μm; 4.6 x 100 mm, 4.6 x 150 mm, 4.6 x 250 mm z High throughput analysis: 3μm, 5μm; 2.1 x 30 mm, 2.1 x 50 mm, 4.6 x 50 mm. z LC-MS application: 3μm, 5μm; 1.0 x 30 mm, 1.0 x 50 mm, 2.1 x 30 mm, 2.1 x 50 mm, 2.1 x 100 mm. z Micro HPLC: 3μm, 5μm; 0.5 x 30 mm, 0.5 x 50 mm, 0.5 x 100 mm. z Preparative HPLC: 5μm, 10μm; 21 x 50 mm, 21 x 150 mm, 21 x 250 mm, 30 x 150 mm, 30 x 250 mm, 50 x 250 mm. Cross-reference for Agela Venusil Series Columns XBP C18 XBP C18 (2) XBP C8 XBP(L) C18 XBP(L) C8 ASB C18 ASB C8 AQ C18 HILIC Agilent SB-C18 R SB-C8 R XDB-C18 R XDB-C8 R SB-Aq R Waters Sunfire-C18 R R Sunfire C8 R Atlantis-C18 (AQ) E Atlantis-HILIC R Phenomenex Luna-C18 E Luna-C8 E Luna-C18 (2) E Supelco Discovery-C18 E Discovery-C8 Asentics-C18 Asentics-C8 E E E GL Science Insertsil ODS-3 R Comparison of Particle Characteristics of Typical HPLC Stationary Phases Stationary Phase Particle (μm) Pore(A) Surface 2 C% (m /g) End High Purity Capping Silica Venusil XBP-C18 (2) 5 100 380 19 double yes Venusil XBP-C18 5 100 380 22 double yes Venusil AQ-C18 5 100 380 18 yes yes Venusil ASB-C18 5 150 200 11 no yse Venusil XBP-C18(L) 5 150 200 14 double yes ZORBAX SB-C18 5 80 180 10 no yes ZORBAX XDB-C18 5 80 180 12 yes yes Waters SunFire C18 5 100 340 16 yes yes Waters Symmetry C18 5 100 335 19 yes yes Waters XTerra MS C18 5 125 — 15.5 yes — Hypersil BDS C18 5 130 170 11 yes no Hypersil ODS 5 120 170 10 yes no Inertsil ODS 5 100 350 14 yes no Inertsil ODS3 5 100 450 15 yes yes Kromasil C18 5 100 340 19 yes special Supelco Discovery C18 5 180 200 12 yes yes Luna C18(2) 5 100 400 17.5 yes yes USP Column Selection Guide USP L01 Specifications Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10μm in diameter. Column Venusil C18 Particle Shape Spherical Octadecyl silane chemically bonded to silica gel of a controlled L02 surface porosity that has been bonded to a solid spherical core, 30 Please call to 50μm in diameter L03 L04 L05 Porous silica microparticles, 5 to 10 μm in diameter Silica gel of controlled surface porosity bonded to a solid spherical core, 30 to 50μm in diameter. Alumina of controlled surface porosity bonded to a solid spherical core, 30 to 50 μm in diameter. Venusil silica Spherical Please call Please call Strong cation-exchange packing: sulfonated fluorocarbon L06 polymer coated on a solid spherical core, 30 to 50 μm in Please call diameter. L07 Octylsilane bonded to totally porous microsilica particles, 3 to 10 μm in diameter. Venusil C8 Spherical Venusil NH2 Spherical Please call Irregular Venusil CN Spherical Venusil Phenyl Spherical An essentially monomolecular layer of aminopropyl-silane L08 chemically bonded to totally porous silica gel support, 10 μm in diameter. L09 L10 L11 10 μm irregular totally porous silica gel having a chemically bonded, strongly acidic cation-exchange coating. Nitrile groups chemically bonded to porous silica microparticles, 3 to 10 μm in diameter. Phenyl groups chemically bonded to porous silica micro-particles, 3 to 10 μm in diameter. Strong anion-exchange packing made by chemically bonding a L12 quaternary amine to a solid silica spherical core, 30 to 50 μm in Please call diameter L13 L14 L15 L16 Trimethylsilane chemically bonded to porous silica microparticles, 3 to 10 μm in diameter. Silica gel, 10 μm in diameter, having a chemically bonded, strongly basic quaternary ammonium anion-exchange coating. Hexyl silane chemically bonded to totally porous silica particles, 3 to 10 μm in diameter. Dimethyl silane chemically bonded to totally porous silica particles, 3 to 10 μm in diameter. Please call Spherical Please call Spherical Please call Please call Spherical Strong cation exchange resin consisting of sulfonated L17 cross-linked styrene-divinylbenzene copolymer in the hydrogen form, 7 to 11 μm in diameter. L18 Amino and cyano groups chemically bonded to porous silica particles, 5 to 10 μm in diameter. Strong cation exchange resin consisting of sulfonated L19 cross-linked styrene-divinylbenzene copolymer in the calcium form, 9 μm in diameter. L20 Dihydroxypropane groups chemically bonded to AKF CISLH columns Please call AKF CISLM columns Please call Spherical Irregular Spherical Spherical USP Column Selection Guide USP L21 L22 Specifications A rigid, spherical styrene-divinylbenzene copolymer, 5 to 10 μm in diameter. A cation exchange resin made of porous polystyrene gel with sulfonic acid groups, about 10 μm in size. Column AKF RP columns AKF CISLH columns Particle Shape Spherical Spherical An ion exchange resin made of porous polymethacrylate L23 or polyacrylate gel with quaternary ammonium groups, Please call Spherical about 10 μm in size. A semi-rigid hydrophilic gel consisting of vinyl L24 polymers with numerous hydroxyl groups on the matrix Please call surface, 32 to 63 μm in diameter. Packing having the capacity to separate compounds with L25 a MW range from 100 to 5000 daltons (as determined by Please call Spherical Venusil C4 Spherical polyethylene oxide), applied to neutral L26 L27 Butyl silane chemically bonded to totally porous silica particles, 5 to 10 μm in diameter. Porous silica particles, 30 to 50 μm in diameter. Please call A multifunctional support, which consists of a high L28 purity, 100 Å spherical silica substrate that has been Please call bonded with anionic (amine) functionality. Gamma alumina, reversed phase, low carbon percentage L29 by weight, alumina-based polybutadiene spherical Please call particles, 5 μm diameter w/a pore diameter of 80 Å L30 Ethyl silane chemically bonded to a totally porous silica particle, 3 to 10 μm in diameter. Please call Irregular A strong anion-exchange resin-quaternary amine bonded L31 on latex particles attached to a core of 8.5 μm Please call macroporous particles having a pore size of 2000 Å. A chiral ligand-exchange packing- L-proline copper L32 complex covanlently bonded to irregularly shaped silica Please call Spherical Please call Spherical Please call Spherical Please call Spherical particles, 5 to 10 μm in diameter. Packing having the capacity to separate proteins of 4,000 L33 to 400,000 daltons. It is spherical, silicabased and processed to provide pH stability. Strong cation exchange resin consisting of sulfonated L34 cross-linked styrene-divinylbenzene copolymer in the lead form, 9 μm in diameter. A zirconium-stabilized spherical silica packing with a L35 hydrophilic (diol-type) molecular monolayer bonded phase having a pore size of 150 Å. L36 L-Phenylglycine-3,5-dinitrobenzoyl on 5 μm aminopropyl silica Nucleosil Chiral-3 Spherical L37 Polymethacrylate gel for proteins 2000~40,000 MW Please call Spherical L38 Methacrylate-based SEC column for water-solubles Please call Spherical Please call Spherical L39 L40 Hydrophilic polyhydroxymethacrylate gel of totally porous spherical resin Cellulose tris-3,5 dimethylphenylcarbamate coated Please call Applications 1.Antibiotics 1.1 Benzylpenicillin Sodium Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: 0.1mol/L potassium dihydrogen phosphate buffer (pH 2.5):ACN=70:30 Detection: UV 225 nm Flow rate: 1 mL/min Injection: 4 μL 1.2 Amoxicillin Sodium Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: Phosphate buffer (0.05mol/L ,pH5.0): ACN=97.5:2.5 Detection: UV 254 nm Flow rate: 1 mL/min Injection: 5 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 1.3 Cefradine Mobile phase: Water/MeOH/3.86% sodiumacetate solution/4% acetic acid solution=742:240:15:3 Detection: UV 254 nm Flow rate: 1 mL/min Injection: 2μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 1.4 Cefaclor Mobile phase: 0.05mol/L phosphate buffer(pH 3.4): ACN=92:8 Detection: UV 254 nm Flow rate: 1 mL/min Injection: 5μL 1.5 Cefadroxil Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: 0.05mol/L phosphate buffe(r pH 5.5): CAN=96:4 Detection: UV 230 nm Flow rate: 1 mL/min Injection: 2μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 1.6 Cefalexin Mobile phase: Water/MeOH/3.86% sodium acetate solution/4% acetic acid solution=742:240:15:3 1.7 Cefotaxime Sodium Detection: UV 254 nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: phosphate buffer(0.4mM KH2PO4+8mM K2HPO4) /MeOH=89:11 1.8 Sulbactam Sodium + Cefoperazone Sodium Detection: UV 254 nm Flow rate: 1 mL/min Injection: 2 μL Column: Venusil XBP C18, (4.6×250 mm,5 μm) Part No.: VX952505-0 Mobile phase: 0.005 mol/L TABOH (adjust pH to 5.0 with H3PO4): ACN =70:30 Detection: UV 220nm Flow rate: 1 mL/min Injection: 2 μL 1.9 Acetylspiramycin Column: Unisol C18(4.6×250mm,5μm) Part No.: UO952505-0 Mobile phase: ACN:NaClO4/ H3PO4 (pH 2.2) =30:70 Temperature: 30℃ Flow rate: 0.8 mL/min Injection: 20 μL Column: Venusil XBP-C8, (4.6×150 mm,5 μm) Part No.: VX851505-0 1.10 Meleumycin Mobile phase: ammonium formate(0.2mol/L, adjust to pH 7.3 with TEA):ACN=62:38 Detection: UV 232nm Flow rate: 1 mL/min Temperature: 30℃ 2.Synthetic antimicrobial agents 2.1 Norfloxacin Column: Venusil XBP C18, (4.6×250 mm,5 μm) Part No.: VX952505-0 Mobile phase: H3PO4 (0.025 mol/L,adjust to pH 3.0 with TEA):ACN=87:13 Detection: UV 278nm Flow rate: 1 mL/min Injection: 20 μL 2.2 Ofloxacin Column: Venusil XBP C18, (4.6×250 mm,5 μm) Part No.: VX952505-0 Mobile phase :NH4AC/ KClO4 (40mM , pH 2.0):ACN=85:15 Detection: UV 294nm Flow rate: 1 mL/min Injection: 4 μL 2.3 Ciprofloxacin Lactate Column: Venusil XBP C18, (4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase: citric acid buffer (0.05 mol/L, adjust to pH 3.5 with TFA):ACN=82:28 2.4 Gatifloxacin hydrochloride Detection: UV 277nm Flow rate: 1 mL/min Injection: 10 μL Column: Venusil XBP C18(L),(4.6×150mm,5 μm) Part No.: VX951505-L Mobile phase:1%TEA(pH 4.5):ACN=87:13 Detection: UV 325nm Flow rate: 1.5 mL/min Injection: 10 μL Temperature: 40℃ 2.5 Fluconazole Column: Venusil XBP C18, (4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase: KH2PO4 buffer(adjust to pH7.0 with NaOH):MeOH=55:45 Detection: UV 260nm Flow rate: 1 mL/min Injection: 10 μL Column: Venusil XBP-C8, (4.6×250 mm,5 μm) Part No.: VX852505-0 3.Anti-virus medicine 3.1 Rifampicin Mobile phase: MeOH/ACN/KH2PO4 (0.075 mol/L)/citric acid (1mol/L)=30:30:36:4 Detection: UV 254nm Flow rate: 1 mL/min Injection: 2 μL 3.2 Ganciclovir Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase:Water:MeOH=95:5 Detection: UV 252nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 4. Steriod Hormones 4.1 Ethinylestradiol Mobile phase:MeOH:Water=70:30 4.2 Triamcinolone Acetonide Detection: UV 281nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: MeOH:Water=21:19 Detection: UV 240nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 4.3 Hydrocortisone Mobile phase: MeOH:Water=70:30 Detection: UV 240nm Flow rate: 1 mL/min Injection: 10 μL 4.4 Dexamethasone Column: Venusil XBP C18, (4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase: citric acid buffer (0.05 mol/L, adjust to pH 3.5 with TFA):ACN=82:28 Detection: UV 277nm Flow rate: 1 mL/min Injection: 10 μL 4.5 Levonorgestrel Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase:MeOH:Water=70:30 Detection: UV 281nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 4.6 Prednisone Mobile phase: Water :THF :MeOH=668:250:62 Detection: UV 254nm Flow rate: 1 mL/min Injection: 2 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 4.7 Clobetasol Propionate Mobile phase: phosphate buffer(0.05 mol/L ,pH 2.5) /ACN/MeOH=425:475:100 Detection: UV 240nm Flow rate: 1mL/min Injection: 2μL 4.8 Fluocinonide Column: Venusil XBP C18 (4.6×150mm,5μm) Part No.: VX951505-0 Mobile phase: MeOH :ACN :Water=60:10:30 Detection: UV 240nm Flow rate: 1 mL/min Injection: 10 μL 5 Medicine for Gastric Ulcer 5.1 Ranitidine Hydrochloride Column: Venusil XBP C18(4.6×150mm,5μm) Part No.: VX951505-0 Mobile phase: MeOH :0.77% Ammonium acetate aq.=285:115 Detection: UV 320nm Flow rate: 1 mL/min Injection: 10 μL 5.2 Cimetidine Column: Venusil XBP C18 (4.6×150mm,5μm) Part No.: VX951505-0 Mobile phase: MeOH:Water:H3PO4:TFA =200:800:0.3:0.2 Detection: UV 220nm Flow rate: 1mL/min Injection: 10 μL 5.3 Omeprazole Column: Venusil XBP-C8(4.6×250mm,5μm) Part No.: VX852505-0 Mobile phase: NaH2PO4 Buffer (0.01 mol/L, adjust to pH7.6 with H3PO4): ACN=60:40 Detection: UV 302nm Flow rate: 1 mL/min Injection: 4 μL 6. Analysis of Alkaloids 6.1 Quaternary Ammonium Alkaloids from Coptidis Column: Unisol C18(4.6×250mm,5μm) Part No.: UO952505-0 Mobile phase: water(0.3%TEA):ACN=75:25 Detection: UV 254nm Flow rate: 1 mL/min Temperature: 25℃ 6.2 Matrine Column: Venusil XBP-NH2(4.6×250mm,5μm) Part No.: VN952505-0 Mobile phase:ACN:Ethanol:3% H3PO4 aq.=80:10:10 Detection: UV 220nm Flow rate: 1 mL/min Injection: 20 μL 6.3 Ephedrine from Coptidis Mobile phase: ACN: SDS/H3PO4=40:60 Detection: UV 210nm Flow rate: 1mL/min 6.4 Berberine from Phellodendron Mobile phase: ACN: 1%TFA=35:65 Detection: UV 346nm Flow rate: 1mL/min 6.5 Aconitine、Mesaconitine、Hypaconitin Mobile phase: ACN: 2% Acetate Buffer (adjust pH to 6.5 with TEA)=15:85 Detection: UV 235nm Flow rate: 1 mL/min 6.6 Morphine from Papaver somniferum Mobile phase: MeOH: CH3COONa aq.(0.03mol/L, adjust pH to 3.5with Acetic acid) =15:85 Detection: UV 238nm Flow rate: 1 mL/min 7.Agricultural Chemical Sample: dazomet、Cymoxanil、Triadimefon、Tebuconazole、 Thiophanate-Methyl、hexaconazole、flutriafol、Iprodione、 7.1 Analysis of 14 Kinds Herbicides Metalaxyl、Procymidone、carboxin、Prochlora、 Diethofencar、Triadimenol、 1,2,3,6-tetrahydro-N-(trichloromethylthio)phthalimide Column: Venusil XBP C18(4.6×150mm,5μm) Part No.: VX951505-0 Mobile phase: A: Ammonium acetate buffer B:ACN Gradient: 40%B to 45%B in 8 min, hold for 40min. 7.2 Haloxyfop-P-methyl Detection: UV 225nm Injection: 20 μL Flow rate: 1 mL/min Temperature: 25℃ Column: Venusil XBP C18(4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase: ACN:Water=70:30 Detection: UV 225nm Flow rate: 1 mL/min Injection: 5 μL Temperature: 25℃ 7.3 Fluazifop-p-butyl Column: Venusil XBP C18(4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase:ACN:Water=70:30 Detection: UV 225nm Flow rate: 1 mL/min Injection: 5 μL Temperature: 25℃ 7.4 1,2-Dibenzoyl-1-tert-butylhydrazine Column: Venusil XBP C18(4.6×150 mm,5 μm) Part No.: VX951505-0 Mobile phase:Water:MeOH =25:75 Detection: UV 254nm Flow rate: 1 mL/min Injection: 10 μL Temperature: 25℃ 8.Analysis of Amino Acid Column: Venusil AA(4.6×250 mm,5 μm) Part No.: AA952505-0 Mobile phase: A: 0.1mol/L CH3COONa(Adjust pH 6.5 with Acetic Acid):Acetonitrile (93:7) B:Water: Acetonitrile (4:1) Gradient: Time(min) 0 11 13.9 14 29 29.1 37 37.1 45 %B 0 7 12 15 34 100 100 0 0 Flow rate: 1mL/min Detection: UV 254nm Temperature: 40℃ Sample: PTC-AA (derivatization of amino acids with PITC) 8.1 Standards of Amino Acids 8.2 Amino Acid from Salmon Calcitonin 8.3 Amino Acid from Terlipressin 9 Applications in LC-MS 9.1 Pseudoephedrine in Plasma Mass system: API Qtrap 3200 Applied Biosystem Mass condition: Cation Detector Mode,MRM HPLC Column: Venusil ASB C18 Column 2.1mm×50mm (Part No.: VS950502-0) Sample: Prepared sample by SPE(Cleanert PCX 60mg/3ml;Part No.: CX0603) Mobile Phase: A: 1% Formic Acid in Water ;B: Methanol Gradient: 20%B to 95%B in 2 min, hold for 0.5 min, then switch to A:B(20:80) Flow Rate: 0.5 mL/min Temperature: 25℃ 9.2 Oleic Acid in Plasma Mass system: API Qtrap 3200 Applied Biosystem Mass condition: Anion Detector Mode,MRM HPLC Column: Venusil ASB C18 Column 2.1mm×50mm (Part No.: VS950502-0) Sample: Prepared sample by SPE(Cleanert PEP 60mg/3ml;Part No.: PE0603) Mobile Phase: A: 13mmol/L ammonium acetate aq. ;B: Acetonitrile Gradient: 5%B to 95%B in 2 min, hold for 2 min., switch to A:B(95:5) then hold for 2 min. Flow Rate: 0.8 mL/min Temperature: 25℃ 10.others 10.1 Glipizide Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 Mobile phase: phosphate Buffer(0.1 mol/L ,pH 6.0):MeOH=55:45 Flow rate: 1mL/min Injection: 20 μL Column: Unisol C18(4.6×150mm,5μm) Part No.: UO951505-0 10.2 Terfenadine Mobile phase:MeOH: H3PO4/Triethylamine (0.1mol/L)=80:20 Detection: UV 254nm Flow rate: 1 mL/min Injection: 10 μL 10.3 Dopamine and Its Metabolin Sample: Dopamine、Isoprenaline、Soprenaline Column: Venusil F5PH(4.6×250mm,5μm) Part No.: VF952505-0 Mobile phase: MeOH: CH3COOH /CH3COONH4 Buffer (pH 4.5) =15:85 Detection: UV 280nm Flow rate: 0.8 mL/min 10.4 Organic Acids Determination of organic acids in Fermentation Broth Sample: Formic acid, acetic acid, maleic acid, succinic acid, fumaric acid Column: Unisol C18(4.6×250 mm,5 μm) Part No.: UO951505-0 Mobile phase: 0.02M NH4AC Aq.:MeOH=95:5 Detection: UV 215nm Flow rate: 1 mL/min Injection: 10 μL Temperature: 20℃ 10.5 Catechins in Tea Sample: Extract of tea Column: Venusil Unisol C18 (4.6×250 mm,5 μm) Part No.: UO952505-0 Mobile phase: 0.02%H3PO4: MeOH=81:19 Detection: UV 278nm Flow rate: 1 mL/min Temperature: 40℃ 10.6 Saccharin Sodium in Milk Powder Sample: Benzoic acid, 2,4-Hexadienoic acid, Sodium saccharine, milk powder Column: Venusil Unisol C18 (4.6×250 mm,5 μm) Part No: UO952505-0 Mobile phase:MeOH:CH3COONH4 (0.02 M) =5:95 Detection: UV 230nm Flow rate: 1 mL/min Temperature: 30℃ 10.7 DHA in the Health Food Column: Unisol C18 (4.6×250 mm,5 μm) Part No.: UO951505-0 Mobile phase:MeOH:Water =80:20 Detection: UV 254nm Flow rate: 1 mL/min Injection: 10 μL 10.8 Tartrazine in Food Column: Unisol C18( 4.6×250 mm,5 μm) Part No.: UO951505-0 Mobile phase: A: Ammonium acetate buffer(pH 4.0);B: MeOH Gradient: 35%B to 50%B in 5 min. Detection: UV 254nm Flow rate: 1 mL/min Injection: 10 μL Column: Venusil ASB C18(4.6×250 mm,5 μm) Part No.: VS952505-0 10.9 Melamine in Feed Mobile phase: 10mM Citric acid+10mM Perfluorooctane sulfonate( pH 3.0) :ACN=85:15 Detection: UV 240nm Flow rate: 1 mL/min Injection: 10 μL Temperature: 40 ℃ 10.10 Tetrodotoxin(TTX) Column: Venusil ASB C18(4.6×250 mm,5 μm) Part No.: VS952505-0 Mobile phase: 0.02% H3PO4:MeOH=40:60 Detection: UV 200nm Flow rate: 0.5mL/min Temperature: 25 ℃ 10.11 Baicalin Column: Venusil ASB C18, (4.6×150 mm,5 μm) Part No.: VA951505-0 Mobile phase: MeOH : 1% acetic acid =50:50 Detection: UV 274nm Flow rate: 1 mL/min Injection: 5 μL APPENDIX Due to interactions between the stationary phase and sample components, HPLC columns may occasionally require cleaning or regeneration. The following conditions apply to silica-based columns. Flow rates should be 1/5 - 1/2 of the typical flow rate. To estimate the column volume, use the following equation: V = column volume in mL V=pr2 / L r = column radius in cm L = column length in cm Rinse with 10 column volumes each of: Hexane, Methylene, Chloride, UNBONDED SILICA COLUMNS (SILICA) Isopropanol, Methylene Chloride. Mobile phase: Flush column with 30mL 2.5% 2,2-dimethoxy- propane and 2.5% glacial acetic acid in hexane REVERSED PHASE COLUMNS (C18, C8, Rinse with 10 column volumes of: 95% Water/5% Acetonitrile (for buffer C4, C2, C1, PHENYL, CN, NH2) removal) followed by 95% Acetonitrile/5% Water mobile phase Rinse with 20 column volumes of mobile phase with buffer removed run REVERSED PHASE PROTEIN/PEPTIDE gradient (2x): A) 0.1% Aqueous TFA in Water B) 0.1% TFA in COLUMNS (C18, C8, C5, C4, PHENYL) Acetonitrile/Isopropanol (1:2) 25% B 100% B for 30 minutes Equilibrate with 10 column volumes of mobile phase. Rinse with 10 column vol umes each of : Chloroform,Isopropanol, Methylene chloride, mobile phase. Exception: Recommended for cleaning BONDED NORMAL PHASE COLUMNS Luna Amino when used in reversed phase mode: 1. Wash with at least 30 (CN, NH2, DIOL ) column volumes of Sodium Hydroxide (pH 11.0) 2. Flush with at least 30 column volumes of Water (HPLC grade) 3. Re-equilibrate to Mobile phase conditions. (300 X 7.8mm size columns) Rinse with 5 column volumes of: 0.1M GFC/SEC COLUMNS FOR PROTEINS Phosphate buffer pH 3.0. For strongly retained proteins: Run 100% Water to 100% Acetonitrile to 100% Water over 60 minutes or wash with 5 column volumes of SDS or 6M Guanidine Thiocyanate or 10% DMSO Rinse with 10 column volumes of: 500mM Phosphate buffer pH 7 10% Acetic acid (Aq) 5 Column Volumes of Water 10 Column Volumes of Phosphate buffer pH 7 5 Column Volumes of Water ION-EXCHANGE COLUMNS 10 Column Volumes of Methanol (SAX, SCX, NH2, DEAE) 10 Column Volumes of Water For protein removal Follow the above procedure with this exception: Substitute 10 column volumes of Methanol with 10 column volumes of 5M Urea or 5M Guanidine Thiocyanate The Methods of Maintaining Good Column Lifetime and Performance z Inject only well-prepared (filtration, liquid/liquid extraction, SPE) clean samples z Minimize pressure surge; avoid mechanical and thermo shock. z Use guard columns or on-line filtration. z Flush columns frequently using an appropriate program z Remove unstable and strongly retained components of no-interest from samples z Use low pH (1-6) mobile phase if possible. z Use organic buffer when operating at medium to high pH (6-10) z Avoid elevated temperature unless it is necessary z Add 200 ppm sodium azide in aqueous mobile phase to suppress the growth of the bacteria z Wash out all buffer salts and store the columns in high organic solution for overnight or long time storage SPE Columns and Wellplates z Cleanert SPE Columns, Wellplates and Media z z The Development of SPE Method ----------------------------------------------------- 103 Applications ---------------------------------------------------------------------------------- 106 Cross-reference Table --------------------------------------------------------------------- 114 z ----------------------------------Cleanert Plus SPE Columns and 96 Wellplates-NEW -------------------------------OMM Technology for SPE-NEW ------------------------------------------------SLE Technology and Sorbents ------------------------------------------------------------Bonded Silica SPE --------------------------------------------------------------------------Non-silica Adsorption Sorbent ------------------------------------------------------------Mixed and Layered Phases ----------------------------------------------------------------Specialized Phases -------------------------------------------------------------------------Cleanert Pre-IC ------------------------------------------------------------------------------ 078 080 082 089 091 097 099 100 102 Cleanert SPE Columns, Wellplates and Media Agela Technologies provides a full line of SPE sorbents, columns and wellplates. OMM SPE Products (Optimized Molecular Modification)- PEP Plus, PEP, PAX, PCX, PWAX, PWCX and PS are all based on polystyrene/divinylbenzene while each phase has different functionality and unique selectivity. They are highly recommended for the extraction of a wide range of compounds in pharmaceutical, agricultural, food, and environmental industries. PEP and PEP Plus are good replacement of Water Oasis® HLB. Average particle diameter: 35-70μm; Average pore size: 80Å; Specific surface area: 600m2/g. SLE(Solid supported Liquid/liquid Extraction) columns and well-plates Specially treated diatomite materials are packed in columns and well plates. The liquid/liquid extraction is run on the surface of the materials, which is easily automated in parallel and time-saving. Bonded silica based SPE column C18, C18-N, C8, NH2, COOH, Silica, PSA, PRS, SCX, SAX; All of them are made of high quality and low metal silica particles. Using the special surface modification methodology, the activity of silica surface is reduced largely, which in turn will reduce the tailing of compounds and will ensure high recovery and good reproducibility. Characteristics of silica particles: Average particle diameter: 50μm Average pore size: 60Å Volume of pore: 0.8cm2/g Specific surface area: 480m2/g Surface of silica: made by special surface modification Non-silica adsorption phase columns-Florisil, PestiCarb, Alumina(N, A, B). They are commonly used to remove polar interference from non-polar samples. Cleanert adsorption sorbents have high purity, high recovery and good reproducibility. They are widely used in sample preparation for environmental and food analysis. Mixed and layered phases-C8/SCX, PestiCarb/NH2, PestiCarb/PSA Specialized phases-SUL-5, DNPH-Silica,HXN New Product! Cleanert Plus SPE Columns and 96 Wellplates Easier, faster and more reliable! Description Cleanert Plus SPE products use the particles with narrowly controlled size distribution, a novel frit material & design, unique pre-activation process on reverse phase, and a pre-drying on normal phase columns. Benefits: Stable flow rate, clogging free: The usual problem of cartridge clogging caused by the sticky and slimy samples can be completely eliminated by using the PEP Plus product line, which makes the sample preparation easier, faster, and more reliable than ever. No activation step is needed, saving 1/3 of work load and time: Using the new Cleanert PEP Plus can save you 1/3 of your work load eliminating the pre-activation steps. PEP Plus does not suffer from vacuum-drying effect, and has balanced adsorption for a wide range of analytes. PEP Plus is the first choice for reverse phase SPE methods development. More consistent performance from normal phase by pre-drying: The new Cleanert Florisil Plus, Cleanert Alumina Plus, Cleanert Pesticarb Plus , Cleanert Silica Plus and Cleanert NH2 Plus will give an unprecedented performance consistency owing to the use of special frits, narrow particle distribution, and pre-drying features. Faster and reliable alternative to liquid/liquid extraction: The new Cleanert SLE Plus Solid Supported Liquid/Liquid Extraction columns and plates use specially treated diatomite materials to run liquid/liquid extraction on solid supports. Cleanert SLE Plus products are designed for automation and parallel process for time saving. Application Examples: SPE-HPLC Analysis of Terramycin in Serum of Mouse using Cleanert PEP Plus method and the result of Cleanert PEP 60mg/3mL method and the result of Cleanert PEP Plus 60 mg/3mL a. Wash with 2mL methanol, 2mL water Preconditioned 12 mins by gravity b. Load 2mL sample solution(the mouse serum which contains 10ppm terramycin); 15 mins by gravity 0 mins Load 2mL sample solution(the mouse serum which contains 10ppm terramycin); 4 mins by gravity c. Wash with 3mL water, then drying the column fully Wash with 3mL water, then drying the column fully d. Elute terramycin with 3mL methanol Elute terramycin with 3mL methanol e. Evaporate the elution by nitrogen at room temperature; Evaporate the elution by nitrogen at room temperature; dissolve dissolve the residue with 2mL mobile phase f. Recovery: 83.2% the residue with 2mL mobile phase Recovery: 81.4% Cleanert PEP Plus Ordering Information Material Sorbent Vol Tubes/box Cat. Number A hydrophilic and lipophilic balanced material, made of polydivinyl benzene functionalized with a polar group 30mg 1mL 100 PE0301-P 50mg 1mL 100 PE0501-P 60mg 3mL 50 PE0603-P 100mg 3mL 50 PE1003-P 200mg 6mL 30 PE2006-P 500mg 6mL 30 PE5006-P 15mg/well 2mL 96-wellplate PE0152-WP 30mg/well 2mL 96-wellplate PE0302-WP 50mg/well 2mL 96-wellplate PE0502-WP Cleanert Florisil Plus Description The new Cleanert Florisol Plus SPE products features a special frit design which made these columns clogging-free. The SPE columns also offer an unique “pre-drying” function to samples by removing water that is contained in the samples. These columns have unprecedented consist performance. Average particle diameter: 80-100μm Pore size: 80Å Specific surface area: 250-300m2/g Ordering Information Material Sodium sulfate/Florisil Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 FS1001-P 200mg 3mL 100 FS2003-P 500mg 3mL 50 FS5003-P 500mg 6mL 50 FS5006-P 1g 6mL 30 FS0003-P 2g 10mL 15 FS2000-P 100mg/well 2mL 96-wellplate FS1002-WP Cleanert Silica Plus Description The new Cleanert Silical Plus SPE products features a special frit design which made these columns clogging-free. The SPE columns also offer an unique “pre-drying” function to samples by removing water that is contained in the samples. These columns have unprecedented consist performance. Average particle diameter: 40-60μm Pore size: 60Å 2 Specific surface area: 480m /g Material Sodium sulfate/Silica Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 SI1001-P 200mg 3mL 100 SI2003-P 500mg 3mL 50 SI5003-P 500mg 6mL 50 SI5006-P 1g 6mL 30 SI0006-P 50mg/well 2mL 96-wellplate SI0502-WP 100mg/well 2mL 96-wellplate SI1002-WP OMM Technology (Optimized Molecular Modification) for SPE New Product! Agela’ s SPE products have been developed based on a thorough understanding of the science, e.g., interactive natures of chemical molecules. Our SPE products can thus better meet customer’ s needs. Our R&D results demonstrated that the adsorption/desorption property of the polymeric SPE materials is regulated by the types of the functional groups and the degree of substitution of the surface modification. In general, modification with electron donor groups will help to retain the electron-deficient molecules, while modification with electronwithdrawing groups will prefer to retain the electron-rich molecules. Different SPE materials have been developed by incorporating proper types of functional groups and degree of substitutions on the surface, and thus providing optimized and balanced performance for all types of molecules. Cleanert PEP (Polar Enhanced Polymer) is a polymer based SPE sorbent which consists of hydrophilically modified divinyl benzene. Cleanert PEP polymer sorbent is water-wettable and it does not suffer from column drying effect. It thus offers consistent performance due to proper wetting capability which is especially important for 96-well plates. It also has high retention for polar compounds and high capacity for a wide spectrum of analytes. Good Water-Wettability The Cleanet PEP (polar polymer) sorbent is a unique hydrophilic-lipophilic balance material. It provides excellent wettability since the sorbent hydrophobic surface is highly modified with polar functional groups. The SPE mechanism follows the reverse phase separation principle. Effect of Drying on Recovery - PEP Versus C18 Sorbents High Retention for Polar Compounds The electron donating and withdrawing functionalities of the sorbent allows it to have enhanced retention for polar compounds. Consistent Performance for Acidic, Neutral and Basic Compounds PEP sorbents are water-wettable, maintaining high retention and high capacity for a wide spectrum of analytes, even when the SPE column runs dry. High Capacity The PEP sorbent has 2-3x more surface area and shows a dramatic increase of sample capacity compared to silica-based C18. The volume of elution solvents can be reduced, and subsequently the total operation time (including solvent evaporation) will be shortened Excellent Batch-to-Batch Reproducibility The OMM technology offers consistent surface modifications and thus batch-to-batch reproducibility. Multiple batches of PEP, PCX, and PAX have been successfully used for various compounds with consistent results. PEP Plus (Pre-conditioned and Clog Resistant) Description The PEP Plus columns are packed with high quality PEP sorbents. The sorbents contain the high surface area polydivinylbenzene spherical particles that are modified with polar groups to offer a balanced hydrophilicity and hydrophobicity. The characteristics of the sorbent are: water-wettable (don’ t suffer from undesirable drying effect), wide usable pH range (1-14), high retention for polar compounds, and high capacity. PEP Plus has a novel frit material & design, and it has undergone a pre-activation process step during manufacturing. This eliminates the need for an activation step prior to use thus reducing working load by ~30%.more than 1/3 work load can be saved. Particle Characteristics 2 Polar and spherica l particles: Average particle size: 40μm; Average pore size: 70Å ;Special surface area: 600m /g Ordering Information Material Cleanert PEP Plus Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 PE0301-P 60mg 3mL 50 PE0603-P 100mg 3mL 50 PE1003-P 200mg 6mL 30 PE2006-P 500mg 6mL 30 PE5006-P 30mg/well 2mL 96-wellplate PE0302-WP 50mg/well 2mL 96-wellplate PE0502-WP 10g PE0010-P 100g PE0100-P PEP(Polar Polymers) Description:PEP (polar polymers, alternative to Oasis HLB) PEP is made of polydivinylbenzene on which the surface is functionalized with vinyl prolidone. The material has a balanced hydrophilic and hydrophobic property and can be used in the entire pH range of 1-14. PEP can be used to extract a variety of polar and non-polar compounds. Some highly hydrophilic compounds which have little retention on C18 columns, such as chlorinated phenols, phosphate esters and drug metabolites, can be effectively retained on PEP Particle Characteristics 2 Functionalized polymer sorbents; Average particle size: 35μm.Average pore size: 80Å; Surface area: 600m /g Ordering Information Material Cleanert PEP Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 PE0301 60mg 3mL 50 PE0603 100mg 3mL 50 PE1003 200mg 6mL 30 PE2006 500mg 6mL 30 PE5006 30mg/well 2mL 96-wellplate PE0302-W 50mg/well 2mL 96-wellplate PE0502-W 10g PE0010 100g PE0100 PAX(RP/Strong Anion Exchange) Description It is designed to overcome the limitations of traditional silica based mixed-mode SPE sorbents such as C18/SAX. It is a RP/strong anionexchange mixed mode polystyrene/divinylbenzene sorbent, stable from pH 0-14. Particle Characteristics Based on functioalized polystyrene/divinylbenzene; Average particle diameter: 40μm; Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 2 600m /g. Ordering Information Material Cleanert PAX Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 AX0301 60mg 3mL 50 AX0603 100mg 3mL 50 AX1003 200mg 6mL 30 AX2006 500mg 6mL 30 AX5006 30mg/well 2mL 96-wellplate AX0302-W 50mg/well 2mL 96-wellplate AX0502-W 10g AX0010 100g AX0100 PCX(RP/Strong Cation Exchange) Description PCX is a mixed-mode, strong cation exchange sorbent. It has reverse-phase and anion-exchange dual functionality. It high surface area and a wide usable pH range of 0-14. Particle Characteristics Based on Functionalized polystyrene/divinylbenzene; 2 Average particle diameter: 40μm; Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 600m /g. Ordering Information Material Cleanert PCX Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 CX0301 60mg 3mL 50 CX0603 100mg 3mL 50 CX1003 200mg 6mL 30 CX2006 500mg 6mL 30 CX5006 30mg/well 2mL 96-wellplate CX0302-W 50mg/well 2mL 96-wellplate CX0502-W 10g CX0010 100g CX0100 PWAX(RP/Weak Anion Exchange) Description Cleanert PWAX provides the dual modes of retention, weak anion exchange and reverse phase on a stable polymer sorbent , which improves the retention for acidic analytes. Particle Characteristics Based on partially functionalized aminopolystyrene/divinylbenzene; Average particle diameter: 40μm; 2/ Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 600m g. Ordering Information Material Cleanert PWAX Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 WAX0301 60mg 3mL 50 WAX0603 100mg 3mL 50 WAX1003 200mg 6mL 30 WAX2006 500mg 6mL 30 WAX5006 30mg/well 2mL 96-wellplate WAX0302-W 50mg/well 2mL 96-wellplate WAX0502-W 10g WAX0010 100g WAX0100 PWCX(RP/Weak Cation Exchange) Description Cleanert PWCX provides the dual modes of retention, weak cation exchange and reverse phase on a stable polymer sorbent, which improves the retention for basic analytes. Particle Characteristics Based on partially functionalized polystyrene/divinylbenzene; Average particle diameter: 40μm; Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 600m2/g. Ordering Information Material Cleanert PWCX Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 WCX0301 60mg 3mL 50 WCX0603 100mg 3mL 50 WCX1003 200mg 6mL 30 WCX2006 500mg 6mL 30 WCX5006 30mg/well 2mL 96-wellplate WCX0302-W 50mg/well 2mL 96-wellplate WCX0502-W 10g WCX0010 100g WCX0100 PEP-ED Description PEP-ED is made of the polydivinylbenzene having a surface functionalized with a electron donating group. They can be used in the entire pH 1-14. The surface has a balanced hydrophilic and hydrophobic property and can extract a variety of polar and non-polar compounds, especially having electron-deficient structures . Particle Characteristics Adsorption sorbents; Average particle size: 35μm.Average pore size: 80Å; Surface area: 600m2/g Ordering Information Material Cleanert PEP ED Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 PE0301-E 60mg 3mL 50 PE0603-E 100mg 3mL 50 PE1003-E 200mg 6mL 30 PE2006-E 500mg 6mL 30 PE5006-E 30mg/well 2mL 96-wellplate PE0302-WE 50mg/well 2mL 96-wellplate PE0502-WE 10g PE0010-E 100g PE0100-E PEP-ER Description PEP-ER is made of the polydivinylbenzene having a surface functionalized with a electron withdrawing group . They can be used in the entire pH 1-14. The surface has a balanced hydrophilic and hydrophobic property and can extract a variety of polar and non-polar compounds, especially having a electron-rich structure Particle Characteristics Adsorption sorbents; Average particle size: 35μm.Average pore size: 80Å; Surface area: 600m2/g Ordering Information Material Cleanert PEP ER Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 PE0301-R 60mg 3mL 50 PE0603-R 100mg 3mL 50 PE1003-R 200mg 6mL 30 PE2006-R 500mg 6mL 30 PE5006-R 30mg/well 2mL 96-wellplate PE0302-WR 50mg/well 2mL 96-wellplate PE0502-WR 10g PE0010-R 100g PE0100-R PS Description PS is made of non-substituted polydivinylbenzene. It has larger surface areas (>600m2/g.) and thus greater capacity than reverse phase bonded silica.PS can be used for the extraction of non-polar and polar compounds. Particle Characteristics Based on polystyrene/divinylbenzene; Average particle diameter: 40μm; 2 Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 600m /g. Ordering Information Material Cleanert PS Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 PS0301 60mg 3mL 50 PS0603 100mg 3mL 50 PS1003 200mg 6mL 30 PS2006 500mg 6mL 30 PS5006 30mg/well 2mL 96-wellplate PS0302-W 50mg/well 2mL 96-wellplate PS0502-W 10g PS0010 100g PS0100 SLE (Solid Supported Liquid/liquid Extraction) Technology and Sorbents This technique utilizes a layer of solid material, which is a type of modified diatomaceous earth, as a support for liquid/liquid extraction. Mechanism z A modified form of diatomaceous earth is packed in a cartridge. z Biological fluid can be applied to the cartridge using gravity flow. z The aqueous sample is deposited as a thin film on the hydrophilic surface. z The analytes are extracted with a water immiscible organic solvent SLE Description Solid supported liquid/liquid Extraction columns and plates use specially treated diatomiteous materials as a solid support for liquid/liquid extractions. The SPE procedures can be easily automated. The General Method Includes: 1. Load an aqueous sample into the column by gravity or a soft vacuum 2. Apply one or a multiple organic solvents by gravity or well-controlled vacuum 3. Vacuum the organic solution which contains the analyte out from bottom of the columns or plates, collect the solution 4. Concentrate the collected solution Ordering Information Material Special treated diatomite Sorbent Vol Tubes/box Cat. Number 200mg 3mL 100 SL2003 500mg 3mL 50 SL5003 500mg 6mL 50 SL5006 1g 6mL 30 SL0006 14g 40mL 10 SL1400 300mg/well 2mL 96-wellplate SL3002-W 500mg/well 2mL 96-wellplate SL5002-W SLE Plus Description Solid Supported Liquid/Liquid Extraction columns and plates. They use the specially treated diatomite materials to run liquid/liquid extractionson the solid supports, which are easily automated in parallel and time saving. Compared with SLE, the SLE Plus has a special frit design which keeps the columns clogging-free, even for very nasty samples. The general method includes: 1. Load an aqueous sample into the column by gravity or a soft vacuum 2. Apply one or a multiple organic solvents by gravity or well-controlled vacuum 3. Vacuum the organic solution which contains the analyte out from bottom of the columns or plates, collect the solution 4. Concentrate the collected solution Ordering Information Material Special treated diatomite Sorbent Vol Tubes/box Cat. Number 200mg 3mL 100 SL2003-P 500mg 3mL 50 SL5003-P 500mg 3mL 50 SL5006-P 1g 6mL 30 SL0006-P 14g 40mL 10 SL1400-P 300mg/well 2mL 96-wellplate SL3002-WP 500mg/well 2mL 96-wellplate SL5002-WP Bonded Silica SPE ODS C18(End-capped) Description ODS C18 products columns and plates are packed with reverse phase, octadecylsilane bonded silica sorbents. The sorbent is double endcapped and has a high bonding density (%C>17). These columns can be used as a replacement for BondElute C18 and Super clean ENVI C18. These products can be used for desalting biomolecules, such as proteins and DNAs. Particle Characteristics Based on silica; C%: 18-19%; Average particle diameter: 50μm; 2 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 480 /g Ordering Information Material Cleanert ODS(C18,end-capped) Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 181001 200mg 3mL 50 182003 500mg 3mL 50 185003 500mg 6mL 30 185006 1g 6mL 30 180006 50mg/well 2mL 96-wellplate 180502-W 100mg/well 2mL 96-wellplate 181002-W 10g 180010 100g 18010 ODS C18-N(Non-end-capped) Description ODS C18-N products have silica based reverse phase sorbents bonded with octadecylsilane without endcapping. The extra silanol residue of the sorbent provides additional polar interactions associated with surface silanol groups which enhance the retention of basic compounds. These columns are similar to Agilent AccuBond C18 and BondElute C18 OH. Particle Characteristics Based on silica; C%: 17-18%; Average particle diameter: 50μm; 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 2 480m /g Ordering Information Material Cleanert (C18,Non-end-capped) Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 181001-N 200mg 3mL 50 182003-N 500mg 3mL 50 185003-N 500mg 6mL 30 185006-N 1g 6mL 30 180006-N 50mg/well 2mL 96-wellplate 180502-N-W 100mg/well 2mL 96-wellplate 181002-N-W 10g 180010-N 100g 180100-N C8 (Octyl) Description The property of C8 products is similar to ODS C18 products. However, this sorbent is slightly less retentive than C18, which facilitates the elution of more hydrophobic substance. C8 is successfully used for the extraction of both water-soluble and fat-soluble vitamins from serum, as well as the desalting of biological macromolecules. Particle Characteristics Based on silica; C%: 9-10%; Average particle diameter: 50μm; 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 480m2/g Ordering Information Material Cleanert C8 Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 81001 200mg 3mL 50 82003 500mg 3mL 50 85003 500mg 6mL 30 85006 1g 6mL 30 80006 50mg/well 2mL 96-wellplate 080502-W 100mg/well 2mL 96-wellplate 081002-W 10g 80010 100g 80100 CN (Cyanopropyl) Description Cyano(CN) SPE have silica based sorbents bonded with cyanopropyl functional group. This polar sorbent exhibits both polar and non-polar interactions. It can be used for extraction of both polar and non-polar molecules in either normal phase reverse phase mode. Particle Characteristics Based on silica; C%: 5-6%; Average particle diameter: 50μm; 2 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 480m /g Ordering Information Material Cleanert CN Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 CN1001 200mg 3mL 50 CN2003 500mg 3mL 50 CN5003 500mg 6mL 30 CN5006 1g 6mL 30 CN0006 50mg/well 2mL 96-wellplate CN0502-W 100mg/well 2mL 96-wellplate CN1002-W 10g CN0010 100g CN0100 NH2 (Aminopropyl) Description NH2 SPE products have silica based sorbents bonded with aminopropyl funtional group. This sorbent can be used in either normal phase or reverse phase mode. It retains the analytes either by a polar adsorption (from non-polar solution) or by weak anion exchange (from aqueous solution). pKa=9.8. Particle Characteristics Based on silica; Average particle diameter: 50μm; 2 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 480m /g Ordering Information Material Cleanert NH2 Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 NH1001 200mg 3mL 50 NH2003 500mg 3mL 50 NH5003 500mg 6mL 30 NH5006 1g 6mL 30 NH0006 50mg/well 2mL 96-wellplate NH0502-W 100mg/well 2mL 96-wellplate NH1002-W 10g NH0010 100g NH0100 PSA 〔(N-aminoethyl) Aminopropyl〕 Description PSA SPE is similar to Cleanert-NH2. PSA has two amino groups with pKa=10.1 and 10.9 respectively. This sorbent is an anion exchanger slightly stronger than NH2. It can be used for the extraction of metal ions by chelating interactions. It is also commonly used to remove organic acids, pigments an metal ions from organic samples such as vegetables and fruits. Particle Characteristics Based on silica; Average particle diameter: 50μm; 2 2 Average pore size: 60Å; Volume of pore: 0.8cm /g;Specific surface area: 480m /g Ordering Information Material Cleanert PSA Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 PA1001 200mg 3mL 50 PA2003 500mg 3mL 50 PA5003 500mg 6mL 30 PA5006 1g 6mL 30 PA0006 50mg/well 2mL 96-wellplate PA0502-W 100mg/well 2mL 96-wellplate PA1002-W 10g PA0010 100g PA0100 SAX (Strong Anion Exchanger) Description SAX SPE products have silica based sorbents bonded with a quaternary amine. This strong anion exchanger is used to extract compounds capable of carrying a negative charge from both aqueous and non-aqueous solutions. They are ideally suit to extraction of weak acids and desalting of biological macromolecules, like BondElute-SAX. Particle Characteristics Based on silica; C%: 9-10%; Average particle diameter: 50μm; Average pore size: 60Å; 2 2 Volume of pore: 0.8cm /g;Specific surface area: 480m /g The ion exchange degree: 0.5meq/g. Ordering Information Material Cleanert SAX Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 SA1001 200mg 3mL 50 SA2003 500mg 3mL 50 SA5003 500mg 6mL 30 SA5006 1g 6mL 30 SA0006 50mg/well 2mL 96-wellplate SA0502-W 100mg/well 2mL 96-wellplate SA1002-W 10g SA0010 100g SA0100 COOH (Weak Cation Exchanger) Description COOH SPE products consist of a propane carboxylic acid on the inner silica surface. The pKa of the carboxylic acid group is approximately 3.8. It is a useful orbent for quaternary ammonium salt and other strong cations. Particle Characteristics Based on silica; C%: 5-6%; Average particle diameter: 50μm; Average pore size: 60Å; Volume of pore: 0.8cm2/g;Specific surface area: 480m2/g Ordering Information Material Cleanert COOH Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 CH1001 200mg 3mL 50 CH2003 500mg 3mL 50 CH5003 500mg 6mL 30 CH5006 1g 6mL 30 CH0006 50mg/well 2mL 96-wellplate CH0502-W 100mg/well 2mL 96-wellplate CH1002-W 10g CH0010 100g CH0100 PRS (Propane Sulfonic Acid) Description PRS SPE sorbent is a silica gel based strong cation exchanger. This sorbent, consisting of a propane sulfonic acid, has slightly less exchange caoability than SCX. It can be applied to the extraction of weak cations, such as pyridine, with high recovery. Particle Characteristics Based on silica; Average particle diameter: 50μm; Average pore 2 2 size: 60Å;Volume of pore: 0.8cm /g;Specific surface area: 480m /g The ion exchange degree: 0.3meq/g. Ordering Information Material Cleanert PRS Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 PR1001 200mg 3mL 50 PR2003 500mg 3mL 50 PR5003 500mg 6mL 30 PR5006 1g 6mL 30 PR0006 50mg/well 2mL 96-wellplate PR0502-W 100mg/well 2mL 96-wellplate PR1002-W 10g PR0010 100g PR0100 SCX (Strong Cation Exchanger) Description SCX products are strong cation exchangers based on silica gel, with benzene sulfonic acid. The sorbent is used to extract positively charged basic compounds or remove the salt from biological samples. It can also be mixed with C18 sorbent to extract the organic bases. Particle Characteristics Based on silica; Average particle diameter: 50μm; Average pore size: 60Å; Volume of pore: 0.8cm2/g;Specific surface area: 480m2/g The ion exchange degree: 0.5meq/g. Ordering Information Material Cleanert SCX Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 SC1001 200mg 3mL 50 SC2003 500mg 3mL 50 SC5003 500mg 6mL 30 SC5006 1g 6mL 30 SC0006 50mg/well 2mL 96-wellplate SC0502-W 100mg/well 2mL 96-wellplate SC1002-W 10g SC0010 100g SC0100 Silica Description Silica SPE product has unbonded, activated irregular silica as the sorbent. This sorbent exhibits high polar interaction and is used for the extraction of weak-polar or non-polar compound, such as oil. In addition, the silanol groups are ionzable at intermediate pH, so it can be used as a weak cation exchanger. Particle Characteristics Based on silica; Average particle diameter: 50μm; Average pore size: 60Å; 2 2 Volume of pore: 0.8cm /g;Specific surface area: 480m /g Ordering Information Material Cleanert Silica Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 SI1001 200mg 3mL 50 SI2003 500mg 3mL 50 SI5003 500mg 6mL 30 SI5006 1g 6mL 30 SI0006 50mg/well 2mL 96-wellplate SI0502-W 100mg/well 2mL 96-wellplate SI1002-W 10g SI0010 100g SI0100 Diol Description Silica based dihydroxy SPE. It is used to extract polar analytes from non-polar solutions. It is a neutral sorbent and extracts compounds by forming hydrogen bonding or polar-polar interaction. As an example, it can be used to extract THC. Particle Characteristics Based on silica; C%: 5-6%; Average particle diameter: 50μm; 2/ 2/ Average pore size: 60Å;Volume of pore: 0.8cm g;Specific surface area: 480m /g Ordering Information Material Cleanert Diol Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 DI1001 200mg 3mL 50 DI2003 500mg 3mL 50 DI5003 500mg 6mL 30 DI5006 1g 6mL 30 DI0006 50mg/well 2mL 96-wellplate DI0502-W 100mg/well 2mL 96-wellplate DI1002-W 10g DI0010 100g DI0100 Non-silica Adsorption Sorbent Florisil (Magnesia Silica) Description PestiCarb is made of graphitized carbon by a distinct surface modification process, and has been used for sample cleanup in pesticide residues in plant or animal tissues. This sorbent can effectively reduce the background noise and increase the sensitivity, the functions of which are similar to Supelco Envicarb. Particle Characteristics Adsorption sorbents; Average particle diameter: 80-100μm (40-60μm optional); 2 Average pore size: 80Å; Specific surface area: 291m /g Ordering Information Material Cleanert Florisil Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 FS1001 200mg 3mL 50 FS2003 500mg 3mL 50 FS5003 500mg 6mL 30 FS5006 1g 6mL 30 FS0006 50mg/well 2mL 96-wellplate FS0502-W 100mg/well 2mL 96-wellplate FS1002-W 10g FS0010 100g FS0100 PestiCarb (Graphitized Carbon) Description PestiCarb is made of graphitized carbon by a distinct surface modification process, and has been used for sample cleanup in pesticide residues in plants or animal tissues. This sorbent can effectively reduce the background noise and increase the sensitivity, the functions of which are similar to Supelco Envicarb. Particle Characteristics Adsorption sorbents; Average particle size: 120-400 mesh. Ordering Information Material Cleanert PestiCarb Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 PC1001 200mg 3mL 50 PC2003 500mg 3mL 50 PC5003 500mg 6mL 30 PC5006 1g 6mL 30 PC0006 50mg/well 2mL 96-wellplate PC0502-W 100mg/well 2mL 96-wellplate PC1002-W 10g PC0010 100g PC0100 Alumina N (Aluminium Oxide;Neutral) Description Alumina N sorbents(pH=7.5) can adsorb molecules by interaction with the aluminum metal center. The neutralized surface allows interaction with compounds whose heteroatoms are electronegative(e.g.N,S,P) or with an electron-rich ,highly aromatic structure. Particle Characteristics Adsorption sorbents; Average particle size: 150 mesh; Average pore size: 58Å; Ordering Information Material Cleanert Alumina N Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 AL1001-N 200mg 3mL 50 AL2003-N 500mg 3mL 50 AL5003-N 500mg 6mL 30 AL5006-N 1g 6mL 30 AL0006-N 50mg/well 2mL 96-wellplate AL0502-N-W 100mg/well 2mL 96-wellplate AL1002-N-W 10g AL0010-N 100g AL0100-N Alumina A (Aluminium Oxide;Acidic) Description Alumina A sorbents(pH=4.5) can be used as strong polar absorbents or mild cation exchangers. This sorbent is processed with a special deactivation procedure which ensures high analytes recovery. Particle Characteristics Adsorption sorbents; Average particle size: 150 mesh; Average pore size: 58Å; Ordering Information Material Cleanert Alumina A Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 AL1001-A 200mg 3mL 50 AL2003-A 500mg 3mL 50 AL5003-A 500mg 6mL 30 AL5006-A 1g 6mL 30 AL0006-A 50mg/well 2mL 96-wellplate AL0502-A-W 100mg/well 2mL 96-wellplate AL1002-A-W 10g AL0010-A 100g AL0100-A Alumina B (Aluminium Oxide; Basic) Description Alumina B products(pH=10) can be used to remove organic acids and phenols in the sample matrix. They have been pre-treated by special deactivation to ensure high analytes recovery. Particle Characteristics Adsorption sorbents; Average particle size: 150 mesh; Average pore size: 58Å. Ordering Information Material Cleanert Alumina B Sorbent Vol Tubes/box Cat. Number 100mg 1mL 100 AL1001-B 200mg 3mL 50 AL2003-B 500mg 3mL 50 AL5003-B 500mg 6mL 30 AL5006-B 1g 6mL 30 AL0006-B 50mg/well 2mL 96-wellplate AL0502-B-W 100mg/well 2mL 96-wellplate AL1002-B-W 10g AL0010-B 100g AL0100-B Mixed and Layered Phases PestiCarb/NH2 Description PestiCarb/NH2 SPE column is packed of 500mg PestiCarb and 500mg NH2.It has been used wildly in analysis of pesticides residue, esp. for the JapanesePositive List System. It can be used in pesticide residue analysis, coloring matter,fatty acid and hydroxybenzene. Particle Characteristics See Pesticarb and Cleanert NH2 Ordering Information Material Sorbent Vol Tubes/box Cat. Number Cleanert PestiCarb/NH2 500mg/500mg 6ml 30 PN0006 C8/SCX Description Mixed mode SPE based on silica of C8 and strong cation-exchange. It is usually used for the extraction of basic drugs from urine or blood Particle Characteristics See C8 and SCX Ordering Information Material Sorbent Vol Tubes/box Cat. Number 50mg 3mL 50 CS0503 130mg 3mL 50 CS1303 300mg 3mL 50 CS3003 500mg 6mL 30 CS5006 1g 6mL 30 CS0006 50mg/well 2mL 96-wellplate CS0502-W 100mg/well 2mL 96-wellplate CS1002-W Cleanert C8/SCX 10g CS0010 100g CS0100 Specialized Phases HXN(Mid Polar Polymers Specially for Sulfonyl Urea Samples) Description HXN is also made of polydivinylbenzene having surface modified with vinylpyrrolidone. This sorbent is specially designed to extract sulfonyl ureas from water and soil at ppb level. It is less polar than PEP and can also be used to extract, enrich and clean up samples from mid polar to high polar compounds. Particle Characteristics Based on polystyrene/divinylbenzene;Average particle diameter: 40μm; Average pore size: 70Å; Volume of pore: 1.2cm2/g; Specific surface area: 600m2/g Ordering Information Material Cleanert HXN Sorbent Vol Tubes/box Cat. Number 30mg 1mL 100 HX0301 60mg 3mL 50 HX0603 100mg 3mL 50 HX1003 200mg 6mL 30 HX2006 500mg 6mL 30 HX5006 30mg/well 2mL 96-wellplate HX0302-W 50mg/well 2mL 96-wellplate HX0502-W 10g HX0010 100g HX0100 SUL-5(Specific Columns for Sulfonamides) Description SUL-5(specific columns for sulfonamides)is specially designed for the extraction of five sulfonamides (SM2,SMM,SMZ,SDM.SQ) in pork. Particle Characteristics Adsorption sorbents. Ordering Information Material Sorbent Vol Tubes/box Cat. Number Cleanert SUL-5 2g 10ml 100 SUL-5 Cleanert Pre-IC: Sample Clean-up Cartridges for the Ion Chromatography Description The sample preparation is necessary not only for HPLC but also for IC. The demands for sample preparation of IC led to a development of a new SPE product family, which we named“Cleanert Pre-IC”, and theycan perform excellently for sample preparation of IC thanks to their sorbent of high capacity and a good flow property Average Part No. The type of resin particle Capacity Application size Sepcificat ion To remove substances such as IC-RP divinylbenzene resin 40μm 300mg/1cc cartridge aromatic dyes, some aromatic carboxylic acids, hydrocarbons, 10 pk and surfactants from sample matrices To remove the phenolic fraction IC-P polyvinylpyrrolidone(PVP) polymer resin 40μm 350mg/1cc of humic acids, tannic acids, cartridge lignins, anthocyanins, and 10 pk azodyes from samples. 16% IC-A cross-linked,styrene-based,anio n-exchangeresin in 40μm 0.7meq/1cc cartridge thebicarbonate form. 10 pk sample solution. alkaline earths and transition acid ,sulfonic acid ,styrene-based,sulfonic and neutralize the strongly acidic To remove high levels of 16% cross-linked,sulfonic IC-H To remove anion contaminant 40μm acid ,cation-exchangeresin in 2.0-2.2meq/1cc metals from sample matrices and cartridge in the neutralization of highly 10 pk alkaline samples such as sodium thehydrogen form hydroxide or sodium carbonate. To remove high levels of alkaline earths and transition 16% cross-linked,sulfonic acid ,sulfonic IC-Na acid ,styrene-based,sulfonic acid ,cation-exchangeresin in thesodium form. 40μm 2.0-2.2me/1cc cartridge metals from sample matrices without acidifying the sample. This ensures good recovery of acid labile analytes such as nitrite. 10 pk To remove chloride, bromide, 16% and iodide from sample cross-linked,styrene-based,sulf IC-Ag onic acid,cation-exchangeresin in the 40μm 2.0-2.2meq/1cc matrices. An IC- H cartridge cartridge should be used after the IC- Ag silverstyrene-based,styrene-bas cartridge to remove dissolved ed,form. Ag. 10 pk To remove SO42- For reproducible, quantitative determinations in styrene-based,sulfonic IC-Ba acid ,cation-exchangeresin in 40μm thebarium form. 2.0-2.2meq/1cc cartridge low-ionic-strength samples, these cartridges should be 10 pk activated with a chloride-based activating solution. Then the added chloride need to be removed. IC-M iminodiacetateresin in theammonium form 40μm 0.4meqmg/1cc cartridge To remove transition metals and matrix elimination of alkali and 10 pk alkaline earth metals. IC-Ag/H It is a layered cartridge that contains IC- Ag resin and IC- H resin. 10 pk IC-Ba/Ag/H It is a layered cartridge that contains IC-Ba resin, IC- Ag resin and IC- H resin. 10 pk The Development of SPE Method There are many factors influenced the establishment of SPE, and the following are the four main ones which must be considered: 1) The Selection of Sorbent Retention Mechanism The guide on this page briefly outlines the decision making process required to choose a suitable extraction mechanism. 2) The Selection of SPE Columns The guide on this page briefly outlines the decision making process required to choose a suitable sorbent. The selection of column packaging and the parameter of sample loading and elution For the normal phase and reversed phase SPE cartridges, the weight of sample can not be exceed the 5% of cartridges. For the ion-exchange mode, the capacity of the ion-exchange must be considered. The table below is the capability and eluted parameter of SPE: Specification Quality of Loading Sample The Minimum Volume of Elution 50mg/1mL 2.5mg 125μL 100mg/1mL 5mg 250μL 200mg/3mL 10mg 500μL 500mg/6mL 25mg 1.2mL 1g/6mL 50mg 2.4mL 3) The Selection of Ideal Elution Solvent Applications Determination of Oleic acid and its Metabolites in Human Plasm SPE Columns Cleanert PAX, 30mg/1mL SPE Procedure 1) Condition: 1mL methanol 2) Equilibration: 1mL water 3) Sample loading: 500 μL standard sample(8% NH3•H2O) 4) Washing: 1 mL 8% NH3•H2O 5) Elution: 5% Formic acid in methanol HPLC Conditions Mobile phase: ACN: 3mmol/L ammonium acetate=85:15 HPLC column: Venusil ASB C18 Column(2.1×50mm) MS Conditions z MS: Qtrap 3200 z Ion Source: ESI z Scan Mode: Negative mode z Single ions monitor (SIM): Oleic acid m/z 281.2; Internal standard substances C17 m/z 269.2 z Multiple reactive monitor (MRM): Metabolite of oleic acid m/z 315.2 →141.1 Determination of Pseudoephedrine Hydrochloride and its Metabolites in Plasm SPE Columns Cleanert PCX, 100mg/1mL SPE Procedure 1) Condition: 1mL methanol 2) Equilibration: 1mL water 3) Sample loading: 500 μL standard sample(8% NH3•H2O) 4) Washing: 1 mL 8% NH3•H2O 5) Elution: 5% Formic acid in methanol HPLC Conditions Mobile phase: A:1% Formic acid;B: Methanol Venusil ASB C18 Column (2.1×50mm) Flow rate: 0.5 mL/min MS Conditions Table of Gradient Elution Program Time(min) Mobile phase A Mobile phase B 0.00 80 20 2.00 5 95 3.00 5 95 3.50 80 20 z MS: Qtrap 3200 z Ion Source: ESI z Scan Mode: Positive mode z Multiple reactive monitor (MRM): Pseudoephedrine Hydrochloride m/z 166.0 →148.1 z Internal standard substances: Lidocaine m/z 235.3→86.1 Determination of Evodiamine and Rutecarpine in Human Serum by LC-MS Description Sample: 50ng/mL in human serum (dilute two times by pure water) SPE column: Cleanert C18, 200mg/3mL SPE Procedure 1) Column activation: 2mL MeOH; 2mL H2O 2) Sample loading: 2mL (diluted) sample, at flow rate of 0.5mL/min 3) Washing: 1mL × 2H2O; drying using N2. 4) Elution: 1mL× 2 Ethyl acetate 5) Evaporation: evaporate solvent under N2 at 40℃ 6) Reconstitution: with 1mL MeOH/water (85/15) and filtrated using 0.45μm membrane LC-MS Conditions Agilent 1100/Trap XCT Column: Venusil XBP-C18, 4.6 × 150mm, 5μm Mobile phase: methanol/ammonium formate = 85/15 Flow: 0.5mL/min; Temp: 25℃; Inj: 10μL; MS: ESI The Recovery of Evodiamine and Rutecarpine in Human Serum Analyte Concentration (ng/mL) Mean Recovery(%) R.S.D.(%) 520 98.1 5.24 52 97.1 2.32 510 91.5 2.48 51 90.5 3.90 Evodiamine Rutecarpine Extraction and Analysis of Malachite Green in Salmon SPE Columns Cleanert Alumina B; Cleanert SCX SPE Procedure 1) Extract the ground fish with ACN; evaporate ACN; dissolve the residue in CH2Cl2. 2) Put Alumina B column on the top of SCX; wash both with 5mL ACN 3) Load the sample (2-3mL) into Alumina B 4) Wash both columns with 5mL ACN 5) Throw away Alumina B, elute the sample from SCX column using 4mL ACN/ammonium acetate(0.1M, pH 4.5)=1:1 HPLC Conditions Column: Venusil XBP-C18, 4.6 × 150mm, 5μm Mobile phase: ACN/ammonium acetate(0.1M, pH 4.5)=80:20; Flow rate: 2mL/min; Temperature: 35℃; Detection: UV 588nm Determination of Clenbuterol in Urine Samples by Mixed- phase SPE and LC-MS SPE Column Cleanert C18/SCX (500 mg/3 mL, prototype) SPE Method 1) Activate the column with 2 mL MeOH, 2 mL 10 mmol HCl aqueous solution; 2) Load 5 mL sample at the flow rate 1 mL/min 3) Rinse the column with 5 mL water, 5 mL MeOH, dry the column 4) Elute analyte with 5 mL 4% ammonia in MeOH. 5) Evaporate the solvent and reconstitute the sample in 1 mL 1% formic acid/MeOH = 9 : 1 Result Recovery = 80-90% for 2 μg/kg dose, RSD<20% The Analysis of Trace Chloramphenicol SPE Column Cleanert Florisil 1000mg/6mL strong cations. SPE Method 1) Condition: 5ml methanol, 5ml ether. 2) Sample loading: 5mL sample 3) Wash: 5ml ether 4) Elution: methanol/ether=7/3 LC-MS Detection Detection of Seven Hydroxybenzenes in Water (PEP) Materials 1) SPE column: Cleanert PEP, 4-nitrophenol 2) Seven kinds of hydroxybenzene: phenol, Cresol, 4-nitrophenol, 2-Chlorophenol, 2,4-Dichlorophenol, 2,4,6-Trichlorophenol, Pentachloro phenol SPE Procedure 1) Column Condition: 5mL Methyl tert-butyl ether/methanol(V/V=10:90) , 5mL/min; 2) Equilibration: 5mL water 3) Sample loading: 1L sample, 10mL/min 4) Washing: 10mL water, then drying using N2 for 20mins 5) Elution: 2mL Methyl tert-butyl ether HPLC Conditions Mobile phase: A: 1% acetic acid, B: 1% acetic acid and methanol HPLC column: AQ C18 (4.6 × 150mm, 5μm); UV Detector Time Mobile Phase Flow Rate (mL/min) UV (nm) 0-15min A:B=50:50 1 275 15-30min A:B=15:85 1.8 295 The Extraction of Five Kinds of Sulfonamides in Pork SPE Method 1) Condition: 5ml 95% acetonitrile 2) Load: 3mL sample which is dissolved by 95% acetonitrile 3) Wash: 5mL 95% acetonitrile 4) Elute:10mL 70% acetonitrile Result of Recoveries of Five Kinds of Sulfonamides in Pork Cleanert PEP Application Testing Examples Nitroanilines Sample 2-nitroaniline and 4-nitroaniline in 0.1% ammonia aqueous solution. SPE Procedure 1) Activation, 3mL methanol, 3mL DI water 2) Loading, 3mL sample 3) Washing: 1mL 0.1% ammonia aqueous solution 4) Elution: 3mL methanol/1%formic acid = 95/5. Drying with N2 and reconstitute the residue using 1mL methanol. HPLC conditions Venusil AQ C18 HPLC column, 4.6x250mm; Mobile phase: Methanol/1%formic acid = 10/90 Results Sample Peak Area(avg) Concentr. (ppm) Peak Area(avg) Std a 20 296740.5 270652 91 b 2 28374.5 31517 111 c 0.2 2830.5 2947 104 a 20 464657.5 456445 98 b 2 45113.5 46537 103 c 0.2 3489.5 4234 121 4-nitroaniline PEP Recovery (%) PEP Aniline and N, N-dimethylaniline Sample Aniline and N, N-dimethylaniline in DI water solution. SPE Procedure 1) Activation, 3mL methanol, 3mL DI water 2) Loading, 3mL sample 3) Washing: 1mL water 4) Elution: 3mL methanol/water = 95/5 Drying with N2 and reconstitute the sample using 1mL methanol. HPLC conditions Venusil AQ-C18 column, 4.6 × 250mm, 5μm Mobile phase: methanol/water = 50/50 Results Peak Area(avg) Recovery (%) PEP PEP 360251 213975 60 20 36686 20672 56 c 2 3563 2870 81 a 200 1418380 1398427 98 b 20 174334 159897 92 c 2 19483 18386 94 d 0.2 2032 1841 91 Sample Concentr. (ppm) Peak Area(avg) Std a 200 b 4-nitroaniline Praziquantel SPE Procedure 1) Condition and equilibrate: 2mL methanol, 2mL water 2) Load: 4mL sample(diluted by 0.2% acetic acid) 3) Wash: 1mL water 4) Elute: 4mL methanol HPLC conditions methanol: water=70 : 30, UV=263nm, H PLC column: Venusil AQ C18, 4.6 × 150mm, 5μm Praziquantel st Gliclazide SPE Procedure 1) Condition and equilibrate: 1mL dichloromethane, 1mL water 2) Load: 4mL sample (diluted by 5mL 50% ACN and water and 10mM K2HPO4) 3) Elute: 4mL methanol HPLC conditions Promosil C18, 20μL, ACN: H2O=60/40, UV=235nm Cross-reference Table Agela Waters Supelco Aglient Varian Cleanert C18 Sep-pak C18 ENVI-18 LC-C18 — Bond Elut C18 Cleanert C18-N — — AccuBOND C18 C8 Cleanert C8 Sep-pak C8 ENVI-8 AccuBOND C8 Bond Elut C8 CN Cyanopropyl Cleanert CN Sep-pak CN LC-CN AccuBOND CN Bond Elut CN NH2 Aminopropyl Cleanert NH2 Sep-pak NH2 LC-NH2 AccuBOND NH2 Bond Elut NH2 Cleanert PSA — — — Bond Elut PSA Cleanert SAX — LC-SAX Cleanert COOH — LC-WCX — Cleanert PRS — — — Cleanert SCX — LC-SCX Silica Cleanert Silica Sep-pak Silica LC-Silica Diol Cleanert Diol Sep-pak Diol LC-Diol PS Cleanert PS — ENVI-Chrom P PEP(Polar polymers) Cleanert PEP Oasis HLB — — PAX Cleanert PAX Oasis MAX — — — PCX Cleanert PCX Oasis MCX — — — HXN Cleanert HXN — — — — ODS C18 ODS C18-N(Non-endcapped) PSA(N-aminoethyl Aminopropyl) SAX(Strong anion exchanger) COOH(Weak cation exchanger) PRS(Propane sulfonic acid) SCX(Strong cation exchanger) AccuBOND SAX AccuBOND SCX Bond Elut C18-OH Bond Elut SAX Bond Elut CBA Bond Elut PRS Bond Elut SCX AccuBOND Bond Elut Silica Silica AccuBOND Diol Bond Elut Diol AccuBOND ENV PS-DVB — Bond Elut Plexa Purification Products z z z Preparative HPLC Columns -----------------------------------------------------Features -------------------------------------------------------------------------Ordering Information -------------------------------------------------------------Flash Chromatography Media and Columns ----------------------------------Flash Chromatography System -------------------------------------------------- 116 118 120 120 125 Preparative HPLC Columns Features Agela Technologies offers a full line of preparative HPLC columns to meet a variety of application needs. Our preparative columns feature: 1.Great scalability 2.Excellent bed stability 3.High loading capacity 4.Broad solvent compatibility,from 100% aqueous to 100% organic solvents (Unisol C18, Unisol Amide, and Venusil ASB-C18) 5.Broad pH range,1-12 (Venusil Durashell) 6.Unique selectivity (Unisol Amide and Venusil ASB-C18) Unisol-Amide: an unique phase from Agela Technologies that offers a good alternative selectivity to reverse phase columns and an excellent solution for purifying highly polar compounds. Durashell RP: High pH tolerance enables the use of high pH mobile phase, which results in great improvement of peak shape and loadability of basic compounds. Column: Unisol Amiide , 4.6 x 250 mm, 5μm Mobile phase:ACN / Water = 85/15~40/60 in 30 min Detection: UV 210nm Excellent Bed Stability Venusil XBP-C18, 20 x 150 mm, 10 μm,>1000 injection Mass Load Comparison Column: C18, 20 x 150 mm, 5μm Sample: Diphenhydramine, 100 mg/mL in DMSO Mobile phase: 10 mM ammonia: ACN=65: 35 Injection: 800μL Analytical/Preparative HPLC Comparison Analytical Preparative Purpose Purpose Information about the composition Obtain pure components Interested in most or all components Interested in one or a few components Characteristics Characteristics Small injection Large injection Reverse phase preferred Normal phase may be preferred 1~5mm internal diameter 1~10cm internal diameter 2-5μm packing materials >5μm packing materials HPLC pump <10mL/min HPLC pump ≥10mL/min Injection usually trouble free May have difficulties for sample injection Maximize detection sensitivity Minimize detection sensitivity Sample solubility less important Sample solubility very important Mobile phase volatility very important; no-volatile additiveis Mobile phase volatility less important prohibited. Ordering Information Pore Size: 100Å Type Dimension Particle Venusil Venusil Venusil Durashell Venusil Venusil (mm) (μm) XBP-C18 XBP-C8 Silica RP ASB-C18 ASB-C8 Semi-preparative 10×150 5 VX951510-0 VX851510-0 VSi951510-0 DS951510-0 VS951510-0 VS851510-0 Semi-preparative 10×250 5 VX952510-0 VX852510-0 VSi952510-0 DS952510-0 VS952510-0 VS852510-0 Preparative 20×50 5 VX950520-0 VX850520-0 VSi950520-0 DS950520-0 VS950520-0 VS850520-0 Preparative 20×150 5 VX951520-0 VX851520-0 VSi951520-0 DS951520-0 VS951520-0 VS851520-0 Preparative 20×250 5 VX952520-0 VX852520-0 VSi952520-0 DS952520-0 VS952520-0 VS852520-0 Preparative 30×100 5 VX951030-0 VX851030-0 VSi951030-0 DS951030-0 VS951030-0 VS851030-0 Preparative 30×150 5 VX951530-0 VX851530-0 VSi951530-0 DS951530-0 VS951530-0 VS851530-0 Preparative 30×250 5 VX952530-0 VX852530-0 VSi952530-0 DS952530-0 VS952530-0 VS852530-0 Guard cartridge 20×10 5 VX950120-0 VX850120-0 VSi950120-0 DS950120-0 VS950120-0 VS850120-0 Semi-preparative 10×150 10 VX901510-0 VX801510-0 VSi901510-0 DS901510-0 VS901510-0 VS801510-0 Semi-preparative 10×250 10 VX902510-0 VX802510-0 VSi902510-0 DS902510-0 VS902510-0 VS802510-0 Preparative 20×50 10 VX900520-0 VX800520-0 VSi900520-0 DS900520-0 VS900520-0 VS800520-0 Preparative 20×150 10 VX901520-0 VX801520-0 VSi901520-0 DS901520-0 VS901520-0 VS801520-0 Preparative 20×250 10 VX902520-0 VX802520-0 VSi902520-0 DS902520-0 VS902520-0 VS802520-0 Preparative 30×100 10 VX901030-0 VX801030-0 VSi901030-0 DS901030-0 VS901030-0 VS801030-0 Preparative 30×150 10 VX901530-0 VX801530-0 VSi901530-0 DS901530-0 VS901530-0 VS801530-0 Preparative 30×250 10 VX902530-0 VX802530-0 VSi902530-0 DS902530-0 VS902530-0 VS802530-0 Preparative 50×150 10 VX901550-0 VX801550-0 VSi901550-0 DS901550-0 VS901550-0 VS801550-0 Preparative 50×250 10 VX902550-0 VX802550-0 VSi902550-0 DS902550-0 VS902550-0 VS802550-0 Guard cartridge 20×10 10 VX900120-0 VX800120-0 VSi900120-0 DS900120-0 VS900120-0 VS800120-0 Pore Size: 100Å Dimension Particle (mm) (μm) Semi-preparative 10×150 5 UO951510-0 UA951510-0 Semi-preparative 10×250 5 UO952510-0 UA952510-0 Preparative 20×50 5 UO950520-0 UA950520-0 Preparative 20×150 5 UO951520-0 UA951520-0 Preparative 20×250 5 UO952520-0 UA952520-0 Preparative 30×100 5 UO951030-0 UA951030-0 Preparative 30×150 5 UO951530-0 UA951530-0 Preparative 30×250 5 UO952530-0 UA952530-0 Guard cartridge 20×10 5 UO950120-0 UA950120-0 Semi-preparative 10×150 10 UO901510-0 UA901510-0 Semi-preparative 10×250 10 UO902510-0 UA902510-0 Preparative 20×50 10 UO900520-0 UA900520-0 Preparative 20×150 10 UO901520-0 UA901520-0 Preparative 20×250 10 UO902520-0 UA902520-0 Preparative 30×100 10 UO901030-0 UA901030-0 Preparative 30×150 10 UO901530-0 UA901530-0 Preparative 30×250 10 UO902530-0 UA902530-0 Preparative 50×150 10 UO901550-0 UA901550-0 Preparative 50×250 10 UO902550-0 UA902550-0 Guard cartridge 20×10 10 UO900120-0 UA900120-0 Type Unisol C18 Unisol Amide Flash Chromatography Media and Columns Column chromatography has been and will be continuously used as a major purification method for synthetic and natural products. Traditional silica-based flash chromatography columns have many drawbacks: 1) high surface activity which causes instability of certain compounds, 2) bad tailing or overly-long retention of basic compounds due to acid/base interaction or metal chelating effect, and 3) poor reproducibility. Agela Technologies Inc developed a technology that can specially deactivate the silica media. Our columns offer significantly improved performance and much less undesirable silica surface activities than the regular flash columns. Our columns may also provide alternative selectivity. Flash CS Silica Columns Ultra pure silica (specially washed with acid and DI water, narrow particle size control and water content control) Column Specification Surface Area: 460- 520m2/g ;Average Pore Size: 52- 68Å ;Surface pH: 6.3-7.2;Water content: 3.0-5.0% ;Average Particle Size: 40-60μm Column Flash Column Size (g) Efficiency (phenylacetone) 120 2000 176 80 1800 108 40 1100 54.6 20 900 30.5 12 700 17.9 4 500 8 Vol.(mL) Aniline Flash Column Tests Report Column: Agela Cleanert CS (40 g), Brand I (40 g Si) Mobile phase: Dichloromethane : methanol = 99 : 1 Detection: 254 nm Temperature: Ambient Flow rate: 20 mL/min Rt: Brand I: 4.373 min; Agela: 4.090 min Chromatography Comparison Sample: Phenyl acetone , 4-aminobenzoicacid Mobile phase: Hexane/ethylacetate (gradient) Detection: 254 nm Temperature: Ambient Flash CM Silica Columns The following figures present a comparison of column performance for an Agela’s deactivated silica column vs an unmodified silica flash column. Chromatogram Comparison of Catechol on Different Silica Test: The silica to be tested was packed into a stainless steel column of 4.6 × 150mm and tested on a HPLC system Conditions: Sample: Catechol 100μg/mL in mobile phase Mobile phase: dichloromethane/methanol = 98/2 Temperature: 30℃ Detection: 254nm Injection: 5μL Silica Characteristics: Average Particle Size: 50μm Average Pore Size: 60Å Shape: Irregular Surface Area: 500m2/g HILIC Flash Chromatography All HILIC phases are available for TLC, HPLC and Flash columns Following the success of Agela’s Venusil HILIC HPLC columns, we are now introducing HILIC phases for the Flash Chromatography applications. Agela’s HILIC columns are compatible with polar and aqueous solvents, such methanol, acetonitrile, and water, which makes the solvent handling much easier compared to that for the normal phase separations. Significantly, because of the easy operation principle in using Agela’s HILIC columns, these columns are designed to last. You will get a great return of the column investment at an already truly affordable price. Applications for HILIC columns are listed below: 1. Solution for compounds that re not soluble in non- or low polar solvents (hexane, IPA, toluene, dichloromethane). 2. Solution for highly polar compounds which have too much retention on silica columns. 3. Solution for a mixture of compounds with a broad range of polarity (non-polar, semi-polar, and high polar) with alternative selectivity. More important, you will get all the benefits at a truly affordable price, and may even lower the cost by multiple uses of the columns! Column: 20g HILIC column Sample: 10 mg of uridine in 3 mL hot water Mobile phase: water Sample: Detection: 254 nm Flow rate: 12 mL/min 100mg VC and 70mg VB2, direct solid loading Sample: 100mg VC and 70mg VB2, direct solid loading Mobile phase: 0-2min EtOAc; 2-22min MeOH(0-100%); 22-52min MeOH Mobile phase: 0.1% TFA : ACN = 99 : 1 Detection: 280 nm Detection: 280 nm Flow rate: 25 mL/min Flow rate: 25 mL/min Quick Work-up Cartridge They are specially designed to replace the conventional aqueous work up /liquid-liquid extraction process as a part of organic synthesis and purification.They are the through-columns packed with wet resin and/or diatomite. How to use : 1 a synthetic mixture is injected directly injected onto a column. 2 chose a solvent which is not immiscible with water to rinse the desired compounds out of column. 3 concentrate the collected solution 4 add the concentrated mixture to a flash column or a HPLC column for further separation. Phase Celite C18 (RP) HILIC SCX (retaining amines) SAX (retaining acids) PEP (RP) Catalyst(metal) remover Size Type Cat. No. 1mL I QWC001 3mL II QWC003 6mL II QWC006 1mL I QW9001 3mL II QW9003 6mL II QW9006 1mL I QWH001 3mL II QWH003 6mL II QWH006 1mL I QWS001 3mL II QWS003 6mL II QWS006 1mL I QWA001 3mL II QWA003 6mL II QWA006 1mL I QWP001 3mL II QWP003 6mL II QWP006 1mL I QWM001 3mL II QWM003 6mL II QWM006 Ordering Information (Compatible with ISCO, Buchi and Biotage flash chromatography instruments) Surface Type Silica (CS) Silica (CM) Silica NH2 Silica ODS HILIC Silica Amount (g) Cat. Number Quantity (pk) 4 CS140004-0 20 12 CS140012-0 20 20 CS140020-0 20 40 CS140040-0 10 80 CS140080-0 5 120 CS140120-0 5 330 CS140330-0 1 800 CS140800-0 1 1500 CS141500-0 1 2500 CS142500-0 1 4 CM140004-0 20 12 CM140012-0 20 20 CM140020-0 20 40 CM140040-0 10 80 CM140080-0 5 120 CM140120-0 5 330 CM140330-0 1 800 CM140800-0 1 4 CN140004-0 20 12 CN 140012-0 20 20 CN 140020-0 20 40 CN 140040-0 10 80 CN 140080-0 5 120 CN 140120-0 5 330 CN 140330-0 1 800 CN 140800-0 1 4 CO140004-0 20 12 CO140012-0 20 20 CO140020-0 20 40 CO140040-0 10 80 CO140080-0 5 120 CO140120-0 5 330 CO140330-0 1 800 CO140800-0 1 4 CH140004-0 20 12 CH140012-0 20 20 CH140020-0 10 40 CH140040-0 10 80 CH140080-0 5 120 CH140120-0 5 330 CH140330-0 1 800 CS140800-0 1 CS: regular silica; CM: general deactivated, low metal and less retentive; NH2: aminopropyl; ODS: C18 reverse phase; HILIC: Hydrophilic interaction column. Bulk Silica Cat. No. Grade Particle Size Pack CS605005-P P 40-60μm 5kg CS605025-P P 40-60μm 25kg CS605005-G G 40-60μm 5kg CS605025-G G 40-60μm 25kg CS605001-P P 40-60μm 1kg CS605002-P P 40-60μm 2.5kg CS605001-G G 40-60μm 1kg CS605002-G G 40-60μm 2.5kg CS608005-P P 70-90μm 5kg CS608025-P P 70-90μm 25kg CS608005-G G 70-90μm 5kg CS608025-G G 70-90μm 25kg CS608001-P P 70-90μm 1kg CS608002-P P 70-90μm 2.5kg CS608001-G G 70-90μm 1kg CS608002-G G 70-90μm 2.5kg P: Reagent Grade; G: Tech.Grade Fritted Empty Cartridges for Filtration or Solid Sample Loading with Screw Caps Volume (mL) Cat. No. Quantity (pk) 3 SLC 0003 50 6 SLC 0006 50 10 SLC 0008 50 30 SLC 0024 30 60 SLC 0040 20 120 SLC 0120 20 Volume (mL) Cat. No. Quantity (pk) 10 mL SLS 0008 1 30 mL SLS 0024 1 50 mL SLS 0040 1 Piston Seals, Cartridge Flash Chromatography System Flash chromatography, is a rapid form of preparative column chromatography, is especially useful in separation and purification of large scale of complex organic intermixture, combinatorial chemistry, drug discovery and natural product research and development. Minimize Method Development Time and Maximize Results! complete most purification within 20 minutes Features & Capabilities Agela FS-2100 "Chemistry-centric" design for all purpose liquid chromatography applications Windows interface wizard method development software with touch screen makes purification a snap, we can adjust the distance between the touch screen and the manager Compact Profile design for limited fume hood space Column accepts any compression module/cartridge combination Pump Patented valveless metering pump, maintenance free, low pulse. Suitable for all organic solvent, good resistance for acid and alkali. Automatic pressure monitoring & alarm for over/under-pressure conditions Exposed accessible fluid path for no leaky surprises. Easily maintain all components Detector adjustable wavelength 190 to 600nm Fraction High volume fraction collection to correlate fractions with chromatogram display Split fraction rack design allows pause-free extended runs and off- line tube changes Peak software generates an optimized purification run. Flow rates are automatically maximized whenever possible to speed purification. Optimized conditioning with pause for sample injection Modify the method Pause and resume the run as necessary. Collect mode Peak, volume, windows Agela FS-2100 Flash Chromatography Workstation Specification Feature/Specification Description Purification Channels 1 Column Cartridge Sizes 4-330g System Solid Sample Capacity 5mg-33g using prepacked SPE-type barrels or self-loaded cartridges Liquid Sample Injection 5-35mL, luer taper syringe port Solvent Delivery Patented valveless metering pump Flow rate 5-100 mL/min. (±1% accuracy), 50-500 mL/min optional Gradient (# of solvents) Binary (2) standard (one optional) System Max Pressure 100 psi (7bar) included software low / high cut-off alarm UV Detection Field changeable filters for 190-600nm wavelength Fraction Tube Sizes 13, 15, 18, 24mm tube racks, scintillation vials, funnels Rack Design Two rack design for extended run without pause and offline tube changes Fraction Architecture Touch Screen Collector Input Touch Screen Video 10.4" TFT, solvent resistant Ports USB,RS-485 Chromatogram display Real-time color , with historical pan/zoom/scroll by time & AU Off-line Run Review Open saved run information for off-line analysis on the touch screen Auto Configuration "Wizard" guided setup with manual override for advanced users Sample ID Sample ID identifies samples in saved run data File system Standard Windows with extended file and folder names Power 100-240V 50/60 Hz Dimensions HxWxD (cm) 60 x 48 x 48cm( 24" x 19" x 19") Warranty One year limited warranty (ask sales representative for details) Flow Pump UV Detector Peak Software General GC Columns z z z z z z z z z z z z z z z z z z z z DA-1 -----------------------------------------------------------------------------DA-1MS -------------------------------------------------------------------------DA-5 -----------------------------------------------------------------------------DA-5MS -------------------------------------------------------------------------DA-35MS ------------------------------------------------------------------------DA-1701 ------------------------------------------------------------------------DA-CarBoWax 20M ------------------------------------------------------------DA-FFAP ------------------------------------------------------------------------DA-INOWAX --------------------------------------------------------------------DA-50+MS ----------------------------------------------------------------------DA-1301 -------------------------------------------------------------------------DA-624 ---------------------------------------------------------------------------DA-PLOT Al 2 O 3 “KCl” -----------------------------------------------------------DA-PLOT Al 2 O 3 “S” -------------------------------------------------------------DA-PLOT Al 2 O 3 “M” ------------------------------------------------------------DA-PLOT MoleSieve -----------------------------------------------------------DA-PLOT GasPro ---------------------------------------------------------------DA-PLOT Q ----------------------------------------------------------------------DA-PLOT U ----------------------------------------------------------------------DA-Blood Alcohol Column ------------------------------------------------------ 128 129 130 131 132 132 133 133 134 135 136 137 138 139 140 141 142 143 144 144 DA-1 z 100% bonded and crosslinked dimethylpolysiloxane z Non-polar, equivalent to USP phase G2 z Solvent rinseable and high temperature limit z Wide range of column dimensions and stationary phase film thicknesses z Low column bleed, inert surface and high efficiency z Most polular for general applications Similar Phases: DB-1, HP-1, Ultra-1, SPB-1, RTX-1, CP-Si 5CB, BP-1, ZB-1, AT-1, MDN-1, OV-1, OV101 Ordering Information ID(mm) Length(m) Film(μ Temperature m) Limit(℃) Cat.No. 0.25 15 0.1 -60 to 325/350 0125-1501 0.25 15 0.25 -60 to 325/350 0125-1502 0.25 15 1 -60 to 325/350 0125-1510 0.25 30 0.1 -60 to 325/350 0125-3001 0.25 30 0.25 -60 to 325/350 0125-3002 0.25 30 1 -60 to 325/350 0125-3010 0.25 60 0.25 -60 to 325/350 0125-6002 0.25 60 1 -60 to 325/350 0125-6010 0.25 100 0.5 -60 to 325/350 0125-0010 0.32 15 0.25 -60 to 325/350 0132-1502 0.32 15 1 -60 to 325/350 0132-1510 0.32 25 0.17 -60 to 325/350 0132-2501 0.32 25 0.52 -60 to 325/350 0132-2505 0.32 25 1.05 -60 to 325/350 0132-2510 0.32 30 0.1 -60 to 325/350 0132-3001 0.32 30 0.25 -60 to 325/350 0132-3002 0.32 30 1 -60 to 325/350 0132-3010 0.32 30 3 -60 to 325/280 0132-3030 0.32 30 4 -60 to 325/280 0132-3040 0.32 30 5 -60 to 325/280 0132-3050 0.32 50 0.17 -60 to 325/350 0132-5001 0.32 50 0.52 -60 to 325/350 0132-5005 0.32 50 1.05 -60 to 300/320 0132-5010 0.32 60 0.25 -60 to 325/350 0132-6002 0.32 60 1 -60 to 300/320 0132-6010 0.32 60 5 -60 to 260/280 0132-6050 0.53 5 0.15 -60 to 325/360 0153-0501 0.53 5 0.88 -60 to 325/360 0153-0508 0.53 5 2.65 -60 to 260/280 0153-0526 0.53 7.5 5 -60 to 260/280 0153-0750 0.53 10 0.88 -60 to 300/320 0153-1008 0.53 10 2.65 -60 to 260/280 0153-1026 0.53 15 0.15 -60 to 320/360 0153-1501 0.53 15 1.5 -60 to 300/320 0153-1515 0.53 15 3 -60 to 260/280 0153-1530 0.53 15 5 -60 to 260/280 0153-1550 0.53 30 0.88 -60 to 300/320 0153-3008 0.53 30 1.5 -60 to 300/320 0153-3015 0.53 30 2.65 -60 to 260/280 0153-3026 0.53 30 3 -60 to 260/280 0153-3030 0.53 30 5 -60 to 260/280 0153-3050 0.53 60 5 -60 to 260/280 0153-6050 DA-1MS z Identical selectivity to DA-1,but with much lower column bleed z Ideal for GC-MS analysis and first choice of new method development Similar phases: HP 1MS,DB 1MS,BPX-1,AT 1MS,ZB-1,Rtx-1,CP-Sil 5CB Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.25 -60 to 325/350 1125-1502 0.25 30 0.1 -60 to 325/350 1125-3001 0.25 30 0.25 -60 to 325/350 1125-3002 0.25 30 0.5 -60 to 325/350 1125-3005 0.25 30 1 -60 to 325/350 1125-3010 0.25 60 0.25 -60 to 325/350 1125-6002 0.32 15 0.25 -60 to 325/350 1132-1502 0.32 25 0.52 -60 to 325/350 1132-2505 0.32 30 0.1 -60 to 325/350 1132-3001 0.32 30 0.25 -60 to 325/350 1132-3002 0.32 30 1 -60 to 325/350 1132-3010 0.32 60 0.25 -60 to 325/350 1132-6002 Limit(℃) Cat.No. DA-5 z 5% phenyl, 95% methylpolysiloxane, bonded and crosslinked z Non-polar, equivalent to USP phase G27 z Solvent rinseable and high temperature limit z Wide range of column dimensions and stationary phase film thicknesses z Low column bleed, inert surface with neutral surface and high efficiency z Most popular for general applications Similar Phases: DB-5, HP-5, Ultra-5, SPB-5, RTX-5, CP-Sil 8CB, BP-5, ZB-5, AT-5, MDN-5, OV-5, SE-52, SE-54 Ordering Information Temperature Length(m) Film(μm) 0.25 15 0.25 -60 to 325/350 0525-1502 0.25 15 1 -60 to 325/350 0525-1510 0.25 30 0.1 -60 to 325/350 0525-3001 0.25 30 0.25 -60 to 325/350 0525-3002 0.25 30 1 -60 to 325/350 0525-3010 0.25 60 0.25 -60 to 325/350 0525-6002 0.25 60 1 -60 to 325/350 0525-6010 0.32 15 0.25 -60 to 325/350 0532-1502 0.32 15 1 -60 to 325/350 0532-1510 0.32 25 0.17 -60 to 325/350 0532-2501 0.32 25 0.52 -60 to 325/350 0532-2505 0.32 25 1.05 -60 to 325/350 0532-2510 0.32 30 0.1 -60 to 325/350 0532-3001 0.32 30 0.25 -60 to 325/350 0532-3002 0.32 30 0.5 -60 to 325/350 0532-3005 0.32 30 1 -60 to 325/350 0532-3010 0.32 50 0.17 -60 to 325/350 0532-5001 0.32 50 0.52 -60 to 325/350 0532-5005 0.32 50 1.05 -60 to 325/350 0532-5010 0.32 60 0.25 -60 to 325/350 0532-6002 0.32 60 1 -60 to 260/280 0532-6010 0.53 10 2.65 -60 to 260/280 0553-1026 0.53 15 1.5 -60 to 300/320 0553-1515 0.53 15 5 -60 to 260/280 0553-1550 0.53 30 0.88 -60 to 300/320 0553-3008 0.53 30 1.5 -60 to 300/325 0553-3015 0.53 30 2.65 -60 to 260/280 0553-3026 0.53 30 5 -60 to 260/280 0553-3050 ID(mm) Limit(℃) Cat.No. DA-5MS z Identical selectivity to DB-5, but with much lower column bleed z Best surface inertness for wide range of compounds z Ideal for GC-MS analysis or new method development Similar Phases: HP-5MS, DB-5MS, BPX-5MS, AT-5MS, Rtx-5MS, CP-Sil 8 CB Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.1 -60 to 325/350 1525-1501 0.25 15 0.25 -60 to 325/350 1525-1502 0.25 15 0.5 -60 to 325/350 1525-1505 0.25 15 1 -60 to 325/350 1525-1510 0.25 30 0.1 -60 to 325/350 1525-3001 0.25 30 0.25 -60 to 325/350 1525-3002 0.25 30 0.5 -60 to 325/350 1525-3005 0.25 30 1 -60 to 325/350 1525-3010 0.25 60 0.1 -60 to 325/350 1525-6001 0.25 60 0.25 -60 to 325/350 1525-6002 0.25 60 0.5 -60 to 325/350 1525-6005 0.25 60 1 -60 to 325/350 1525-6010 0.32 15 0.1 -60 to 325/350 1532-1501 0.32 15 0.25 -60 to 325/350 1532-1502 0.32 15 0.5 -60 to 325/350 1532-1505 0.32 15 1 -60 to 325/350 1532-1510 0.32 25 0.52 -60 to 325/350 1532-2505 0.32 30 0.1 -60 to 325/350 1532-3001 0.32 30 0.25 -60 to 325/350 1532-3002 0.32 30 0.5 -60 to 325/350 1532-3005 0.32 30 1 -60 to 325/350 1532-3010 0.32 60 0.1 -60 to 325/350 1532-6001 0.32 60 0.25 -60 to 325/350 1532-6002 0.32 60 0.5 -60 to 325/350 1532-6005 0.32 60 1 -60 to 325/350 1532-6010 Limit(℃) Cat.No. DA-35MS z Bonded and 35% phenyl backbone 65% dimethylsiloxane phase z Equivalent to USP phase G-42 z Inert to many active compounds z Low column bleed to improve detection sensitivity and quantitation z Applications: Acroclors, PCBs, amines, pesticides, pharmaceutical molecules. Similar Phases: HP-35MS, DB-35, BPX-35, AT-35, Rtx-35, SPB-35 Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.25 40 to 320/340 3525-1502 0.25 30 0.15 40 to 320/340 3525-3001 0.25 30 0.25 40 to 320/340 3525-3002 0.25 60 0.25 40 to 320/340 3525-6002 0.32 15 0.25 40 to 320/340 3532-1502 0.32 30 0.25 40 to 320/340 3532-3002 0.32 60 0.25 40 to 320/340 3532-6002 0.53 15 1 40 to 300/320 3553-1510 0.53 30 0.5 40 to 300/320 3553-3005 0.53 30 1 40 to 300/320 3553-3010 Limit(℃) Cat.No. DA-1701 z Bonded and crosslingked 14% Cyanopropyl-phenyl 86% dimethylsiloxane phase z Low to mid polarity z Inert to many active compounds z Applications: pesticides, herbiciders, halogenates. Good confirmation of analysis of active compounds on DA-5MS columns. Similar phases: DB-1701, ZB-1701, BP-10, Rtx-1701, CP-Sil 19 CB Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.15 -20 to 280/300 6125-1501 0.25 15 0.25 -20 to 280/300 6125-1502 0.25 15 1 -20 to 280/300 6125-1510 0.25 30 0.15 -20 to 280/300 6125-3001 0.25 30 0.25 -20 to 280/300 6125-3002 0.25 30 1 -20 to 280/300 6125-3010 0.25 60 0.15 -20 to 280/300 6125-6001 0.25 60 0.25 -20 to 280/300 6125-6002 0.25 60 1 -20 to 280/300 6125-6010 0.32 15 0.15 -20 to 280/300 6125-1501 Limit(℃) Cat.No. DA-CarBoWax 20M z Polyethylene glycol (PEG), MW 20,000 z Non-Bonded non-crosslinked phase z Polar phase, equivalent to USP phase G16 z Replacement of packed columns with Carbowax 20M modified Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.2 25 0.1 60 to 220 2220-2501 0.2 50 0.1 60 to 220 2220-5001 0.25 30 0.25 60 to 220 2225-3002 0.32 25 0.3 60 to 220 2232-2503 0.32 50 0.3 60 to 220 2232-5003 0.53 10 1.33 60 to 210 2253-1013 0.53 30 1.33 60 to 210 2253-3013 Limit(℃) Cat.No. DA-FFAP z Nitroterephthalic acid modified Polyethylene glycol (PEG) z Bonded and crosslinked z Non-alcohol/aqueous solvent rinseable z High temperature limit z Polar phase equivalent to USP phase G35 z Designed for the analysis of volatitle fatty acids and phenols Simlar Phases: HP-FFAP, DB-FFAP, CB-WAX58 (FFAP) CB, Stabilwax-DA, BP-21, 007-CW, AT-100 Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.25 60 to 240/250 2125-1502 0.25 30 0.25 60 to 240/250 2125-3002 0.32 15 0.25 60 to 240/250 2132-1502 0.32 25 0.5 60 to 240/250 2132-2505 0.32 30 0.25 60 to 240/250 2132-3002 0.32 50 0.5 60 to 240/250 2132-5005 0.53 10 1 60 to 240 2153-1010 0.53 15 1 60 to 240 2153-1510 0.53 30 1 60 to 240 2153-3010 Limit(℃) Cat.No. DA-INOWAX z Bonded and crosslinked Polyethylene glycol (PEG) z Solvent washable z Highest temperature limits of bonded PEG phases z Polar phase, equivalent to USP phase G16 z Wide applications of polar solvent analysis in food, pharma., cosmetics, petrochemical industries Similar Phases: HP-INNOWax, DB-WAX, DB-WAXetr, SupelcoWAX 10, CP-WAX 52 CB, CB-WAX, Stablilwax, BP-20, 007-CW, AT-Wax, Rtx-Wax, ZB-Wax, HP-20M Ordering Information ID(mm) Length(m) Film(μm) Temperature Limit(℃) Cat.No. 0.2 25 0.2 40 to 260/280 2020-2502 0.2 25 0.4 40 to 260/280 2020-2504 0.2 50 0.2 40 to 260/280 2020-5002 0.2 50 0.4 40 to 260/280 2020-5004 0.25 15 0.25 40 to 260/280 2025-1502 0.25 15 0.5 40 to 260/280 2025-1505 0.25 30 0.15 40 to 260/280 2025-3001 0.25 30 0.25 40 to 260/280 2025-3002 0.25 30 0.5 40 to 260/280 2025-3005 0.25 60 0.15 40 to 260/280 2025-6001 0.25 60 0.25 40 to 260/280 2025-6002 0.25 60 0.5 40 to 260/280 2025-6005 0.32 15 0.25 40 to 260/280 2032-1502 0.32 15 0.5 40 to 260/280 2032-1505 0.32 30 0.15 40 to 260/280 2032-3001 0.32 30 0.25 40 to 260/280 2032-3002 0.32 30 0.5 40 to 260/280 2032-3005 0.32 60 0.15 40 to 260/280 2032-6001 0.32 60 0.25 40 to 260/280 2032-6002 0.32 60 0.5 40 to 260/280 2032-6005 0.53 15 1 40 to 240/260 2053-1510 0.53 30 1 40 to 240/260 2053-3010 0.53 60 1 40 to 240/260 2053-6010 DA-50+MS z Bonded and crosslinked 50% phenyl backbone 50% dimethylsiloxane phase z Equivalent to USP phase G-3 z Inert to many active compounds z Low column bleed to improve detection sensitivity and quantization z Applications: Common drug screens, phenols, PAHs, free steroids, pesticides, herbicides. Good confirmation of the analysis of active compounds on AB-5MS or AB-35MS columns Similar Phases: HP-50+, DB -7, DB-17MS, BPX-50, AT-50, Rtx-50, SPB-50 Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.2 12 0.16 40 to 320/340 5020-1201 0.2 12 0.31 40 to 320/340 5020-1203 0.2 25 0.16 40 to 320/340 5020-2501 0.2 25 0.31 40 to 320/340 5020-2503 0.2 50 0.31 40 to 320/340 5020-5003 0.25 15 0.15 40 to 320/340 5025-1501 0.25 15 0.25 40 to 320/340 5025-1502 0.25 15 0.5 40 to 320/340 5025-1505 0.25 30 0.15 40 to 320/340 5025-3001 0.25 30 0.25 40 to 320/340 5025-3002 0.25 30 0.5 40 to 320/340 5025-3005 0.25 60 0.25 40 to 320/340 5025-6002 0.32 15 0.15 40 to 320/340 5032-1501 0.32 15 0.25 40 to 320/340 5032-1502 0.32 15 0.5 40 to 320/340 5032-1505 0.32 30 0.15 40 to 320/340 5032-3001 0.32 30 0.25 40 to 320/340 5032-3002 0.32 30 0.5 40 to 320/340 5032-3005 0.32 60 0.25 40 to 320/340 5032-6002 0.32 60 0.5 40 to 320/340 5032-6005 0.53 15 1 40 to 300/320 5053-1510 0.53 30 0.5 40 to 300/320 5053-3005 0.53 30 1 40 to 300/320 5053-3010 Limit(℃) Cat.No. DA-1301 z Bonded and crosslinked 6% Cyanopropyl-phenyl 94% dimethylsiloxane phase z Equivalent to USP phase G-43, low to mid polarity z Inert to many active compounds z Applications: pesticides, herbiciders, halogenates. Good confirmation of the analysis of active compounds on DA-5MS or DA-35MS columns Similar Phases: HP-1301, DB-1301, BP-10, Rtx-1301 Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 15 0.25 -20 to 280/300 6025-1502 0.25 15 1 -20 to 280/300 6025-1510 0.25 30 0.25 -20 to 280/300 6025-3002 0.25 30 1 -20 to 280/300 6025-3010 0.25 60 0.25 -20 to 280/300 6025-6002 0.25 60 1 -20 to 280/300 6025-6010 0.32 15 0.25 -20 to 280/300 6032-1502 0.32 15 1 -20 to 280/300 6032-1510 0.32 30 0.25 -20 to 280/300 6032-3002 0.32 30 1 -20 to 280/300 6032-3010 0.32 60 0.25 -20 to 280/300 6032-6002 0.32 60 1 -20 to 280/300 6032-6010 0.53 15 1 -20 to 260/280 6053-1510 0.53 30 1 -20 to 260/280 6053-3010 0.53 30 1.5 -20 to 260/280 6053-3015 Limit(℃) Cat.No. DA-624 z Bonded and crosslinked specially designed stationary phase for EPA methods z Mid-polarity z Inert to many active compounds z Applications: EPA methods: 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240,8260 Similar Phases: DB-624, ZB-624, AT-624, Rtx-624, CP-624 Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.2 25 1.12 -20 to 260 6220-2511 0.25 30 1.4 -20 to 260 6225-3014 0.25 60 1.4 -20 to 260 6225-6014 0.32 30 1.8 -20 to 260 6232-3018 0.32 60 1.8 -20 to 260 6232-6018 0.53 30 3 -20 to 260 6253-3030 0.53 60 3 -20 to 260 6253-6030 0.53 75 3 -20 to 260 6253-7530 Limit(℃) Cat.No. DA-PLOT Al2O3 “KCl” z Least selective ("polar") aluminum oxide phase z Deactivated with KCl z Good baseline separation of most C1 to C10 hydrocarbons z Olefins may co-elute with corresponding paraffin over C5 z Minimum surface adsorption of dienes and halocarbons z ASTM recommended phase z Preferred choice of hydrocarbon separation Similar Phases: HP-PLOT Al2O3/KCL, GS-Alumina/KCL, CP-Al2O3/KCl PLOT, ZB-Alumina/KCl Temperature ID(mm) Length(m) Film(μm) 0.25 25 5 -60 to 200/250 8125-2505 0.25 30 5 -60 to 200/250 8125-3005 0.32 15 8 -60 to 200/250 8132-1508 0.32 30 8 -60 to 200 8132-3008 0.32 50 8 -60 to 200 8132-5008 0.53 15 15 -60 to 200/250 8153-1515 0.53 30 15 -60 to 200 8153-3015 0.53 50 15 -60 to 200 8153-5015 0.53 60 15 -60 to 200 8153-6015 Limit(℃) Cat.No. DA-PLOT Al2O3 “S” z Good selective (mid "polar") aluminum oxide phase z Deactivated with Na2SO4 salt z Excellent baseline separation of C1 to C10 hydrocarbons, excellent of C3, C4 isomer baseline separations z Less accurate quantitations of dienes and halocarbons z ASTM recommended phase z Preferred choice of hydrocarbon separation Similar Phases: HP-PLOT Al2O3/"S", GS-Alumina, CP-Al2O3/Na2SO4 PLOT, ZB-Alumina, RT-Alumina Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 25 5 -60 to 200/250 8225-2505 0.25 30 5 -60 to 200/250 8225-3005 0.32 15 8 -60 to 200/250 8232-1508 0.32 30 8 -60 to 200 8232-3008 0.32 50 8 -60 to 200 8232-5008 0.53 15 15 -60 to 200/250 8253-1515 0.53 30 15 -60 to 200 8253-3015 0.53 50 15 -60 to 200 8253-5015 0.53 60 15 -60 to 200 8253-6015 0.25 25 5 -60 to 200/250 8325-2505 0.25 30 5 -60 to 200/250 8325-3005 0.32 15 8 -60 to 200/250 8332-1508 0.32 30 8 -60 to 200 8332-3008 0.32 50 8 -60 to 200 8332-5008 0.53 15 15 -60 to 200/250 8353-1515 0.53 30 15 -60 to 200 8353-3015 0.53 50 15 -60 to 200 8353-5015 0.53 60 15 -60 to 200 8353-6015 Limit(℃) Cat.No. DA-PLOT Al2O3 “M” z Strong selective (most "polar") aluminum oxide phase z Deactivated with Na2MoO4 salt z Mostly baseline separation of C1 to C10 hydrocarbons, good baseline separation of cyclopropane from propylene z Accurate quantitations of dienes and halocarbons z ASTM recommended phase z Preferred choice of hydrocarbon separation Similar Phases: HP-PLOT Al2O3/"M", GS-Alumina, ZB-Alumina Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.25 25 5 -60 to 200/250 8325-2505 0.25 30 5 -60 to 200/250 8325-3005 0.32 15 8 -60 to 200/250 8332-1508 0.32 30 8 -60 to 200 8332-3008 0.32 50 8 -60 to 200 8332-5008 0.53 15 15 -60 to 200/250 8353-1515 0.53 30 15 -60 to 200 8353-3015 0.53 50 15 -60 to 200 8353-5015 0.53 60 15 -60 to 200 8353-6015 Limit(℃) Cat.No. DA-PLOT MoleSieve z Molecular Sieve, Zeolite, 5A z Thin and thick coatings for push limit separations, e.g. Ar/O2 separation at 35C, O2/N2 with 15sec z Truly immobilized coating and smooth baseline workable for valve switching z Preferred column to analyze fixed gases from hydrocarbon streams z Elution order, H2, He, Ne, O2, N2, CH4, CO - Regeneration of performance from water/CO2 adsorptions at 250℃ for 3hr z ASTM recommended phase z Noble gas, air from methane, fuel cell, etc z Often used with other PLOT columns for fixed gas separation from sample matrix Similar Phases: HP-PLOT Molesieve, CP-PLOT MoleSieve. Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.32 5 12 -80 to 300 8432-0512 0.32 15 12 -80 to 300 8432-1512 0.32 30 12 -80 to 300 8432-3012 0.32 15 25 -80 to 300 8432-1525 0.32 30 25 -80 to 300 8432-3025 0.53 5 25 -80 to 300 8453-0525 0.53 15 25 -80 to 300 8453-1525 0.53 30 25 -80 to 300 8453-3025 0.53 15 50 -80 to 300 8453-1550 0.53 30 50 -80 to 300 8453-3050 Limit(℃) Cat.No. DA-PLOT GasPro z Proprietary Silica base phase z Very inert to wide range of gases including sulfur gases and Freons, symmetric peak shapes z Truly immobilized coating and smooth baseline workable for valve switching z Preferred column to analyze sulfur gases from hydrocarbon streams and air z Separation of CO and CO2 z No effect of water on retention time z Regeneration of performance from water adsorptions at 250℃ for 3hr z ASTM recommended phase z GC-MS applicable Replacement: GS-GasPro, CP-Silica PLOT Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.32 5 5 -80 to 260/300 8532-0505 0.32 15 5 -80 to 260/300 8532-1505 0.32 30 5 -80 to 260/300 8532-3005 Limit(℃) Cat.No. DA-PLOT Q z Divinylbenzene polymer particle, non-polar, close to traditional PoraPak Q z Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures z Highest temperature limit, up to 280/300℃ z Baseline separation of Air, CO2, water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons such as refinery stream, natural gas, and engine exhaust z Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons z Excellent inertness and long lifetime of water/alcohol sample, a good secondary choice of wax column for alcohol analysis z Excellent tolerance to strong acid/base sample without affecting retention time z Good anti-oxidation at 280℃ and fast regeneration of performance z Observed slight sulfur gas, hydrogen chlorine, and amine absorption z Water peak is tailing, but no effect on retention z Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions z Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection z Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery gas, dienes, ethylene, propylene Replacement: HP-PLOT Q, GS-Q, CP-PoraPLOT Q HT, Supel PLOT Q, Rt-Q, ZB-PLOT Q Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.32 15 15 -80 to 280/290 8632-1515 0.32 30 15 -80 to 280/290 8632-3015 0.53 15 30 -80 to 280/290 8653-1530 0.53 30 30 -80 to 280/290 8653-3030 Limit(℃) Cat.No. DA-PLOT U z Divinylbenzene and Ethylene glycol dimethacrylate copolymer particle, polar, close to traditional PoraPack U z Truly immobilized coating and smooth baseline workable for valve switching and liquid sample introduction at low temperatures z Improved separation and selectivity of Air, CO2, water, sulfur gases, hydrogen chlorine, ammonia/light amines from hydrocarbons z Symmetric water peak shape, water elute after C3 z Excellent separation of C1 to C3 isomers, good separations of C3 to C12, halocarbons z Excellent inertness and long lifetime of water/alcohol sample, a good secondary choice of wax column for alcohol analysis z Excellent tolerance to strong acid/base sample without affecting retention time z Observed slight sulfur gas, hydrogen chlorine, and amine absorption z Good choice for analyzing low level solvent residues from wide samples, such as headspace, aqueous, or organic solutions z Preferred column for residue analysis in petroleum industry, pharmaceutical, environmental, chemical weapon detection z Preferred column to analyze polar compounds including oxygenates from hydrocarbon streams: natural gas, refinery gas, dienes, ethylene, propylene Replacement: HP-PLOT U, CP-PoraPLOT U Ordering Information Temperature ID(mm) Length(m) Film(μm) 0.32 15 10 -80 to 190/200 8732-1510 0.32 30 10 -80 to 190 8732-3010 0.32 30 20 -80 to 190 8732-3020 0.53 15 20 -80 to 190/200 8753-1520 0.53 30 20 -80 to 190 8753-3020 Limit(℃) Cat.No. DA-Blood Alcohol Column z Proprietary PLOT phase z Reliable blood alcohol analysis z Tolerance of direct sample injection z Excellent confirmation column to other blood alcohol columns using t-butanol as internal standard Ordering Information ID(mm) Length(m) Film(μm) 0.32 7.5 10 Temperature Limit(℃) -80 to 260/280 Cat.No. 8932-0710 Equipments, Accessories and Supplies z HPLC Accessories and Supplies Column Savor –Online Filter HPLC Mixer HPLC Fittings and Tubing HPLC Injector and Sample Loop Automated Switching Valve Automatic Column Selector HPLC Column Heater UV Lamps z SPE Accessories and Supplies SPE Vacuum Manifolds Multipurpose SPE Work-station SPE-1 Automated Processing Station Positive Pressure SPE Work-station Robotic SPE Work-station Solvent Evaporator Empty Column and Accessories Pipettes and Accessories z GC Accessories and Supplies Septa Injection Port Liners Ferrules Column Scribe 1/32” Ultra Low Mass External Unions z Filtration Products Syringe Filters 96 well filtration plates and collection plates Membrane Filters Glass Filtration System Chemical Resistance Guide for Membranes z Vials and Caps Screw Neck Vials and Caps Crimp Neck Vials and Caps Plastic Vials (Micro-vials for LC-MS Autosamplers) HPLC Accessories and Supplies Column Savor –Online Filter Online Filters z Totally PEEK polymer wetted surfaces z Biocompatible and inert z For analytical systems z High-pressure applications Ordering Information Cat.No. Description OFP-001 PEEK, ZDV Inlet Solvent Filters Bottom-of-the-Bottle Solvent Filters Cat.No. 10um Filter Assembly¹,for 1/8˝ OD tubing with A•520 replaceable filter cup AA•550 2um Filter Assembly¹,for 1/8˝ OD tubing with A•522 replaceable filter cup AA•551 10um Filter Assembly²,for 3/16˝ OD tubing with A•520 replaceable filter cup AA•552 2um Filter Assembly²,for 3/16˝ OD tubing with A•522 replaceable filter cup AA•553 Replacement Filter Cups (For AA•550-AA•553 Filters) 10um Stainless Steel Cups,10-pk AA•520x 2um Stainless Steel Cups,10-pk AA•522x HPLC Mixer Static Bed Mixers Ordering Information Mixer cartridge Applicable Vol. Flowrate(μL) 50 20-150 SMX050 150 150-500 SMX150 250 500+ SMX250 Cat.No. HPLC Fittings and Tubing One-piece Fingertight Fittings All of One-piece Fingertight Fittings are designed to be used with 1/16” OD tubing, except the AM-645(1/32”) and AP-100(1/8”) Cat.No. Material Tubing Size /Nut Threads Qty AF-100 Kel-F 1/16”, 10 • 32 10-pk AF-120 PEEK 1/16”, 10 • 32 10-pk AF-127 PEEK 1/16”, 10 • 32 10-pk AF-130 PEEK 1/16”, 10 • 32 10-pk AM-645 PEEK/Kel-F 1/32”, 6 • 40 10-pk AP-100 Kel-F 1/8”, 1/4 • 28 each Two-piece Fingertight Fittings Cat.No. Material Tubing Size /Nut Threads Qty AF-200 Delrin 1/16”OD, 10 • 32 10-pk AF-300 PEEK 1/16”OD, 10 • 32 10-pk AF-330 Long PEEK 1/16”OD, 10 • 32 10-pk AF-331 Short PEEK 1/16”OD, 10 • 32 10-pk AF-200n Delrin 1/32”OD, 10 • 32 ea AF-300n PEEK 1/32”OD, 10 • 32 ea AF-330n Long PEEK 1/32”OD, 10 • 32 ea AF-331n Short PEEK 1/32”OD, 10 • 32 ea Connections (Unions and Tees) Unions Type Material OD Cat.No. High Pressure, webbed PEEK ZDV 1/16" UNP-001 High Pressure, webbed Stainless Steel ZDV 1/16" UNS-001 Tees Type Material OD Cat.No. High Pressure PEEK 1/16" TEP-001 1/16" TES-001 High Pressure Stainless Steel PEEK Tubing PEEK polymer tubing is a good replacement of stainless steel tubing used commonly in HPLC systems. It has many advantages over the stainless steel tubing, which includes better chemical inertness, better biocompatibility, and convenience to cut. Additionally, PEEK tubing has a very smooth internal surface, which causes less turbulence than metal tubing. Unlike other polymer tubing, PEEK tubing can tolerate high pressure (up to 7000 psi) and high temperature (up to 100℃). Cat.No. ID Pressure Rating AT1560 0.0025˝( 65 μm ) 7,000psi (483bar)* AT1561 0.004˝ (100 μm ) 7,000psi (483bar)* AT1535 0.005˝ (125 μm ) 7,000psi (483bar)* AT1562 0.006˝ (150 μm ) 7,000psi (483bar)* AT1536 0.007˝ (175 μm ) 7,000psi (483bar)* AT1531 0.010˝ (0.25mm) 7,000psi (483bar)* AT1565 0.015˝ (0.40mm) 7,000psi (483bar)* AT1532 0.020˝ (0.50mm) 7,000psi (483bar)* AT1533 0.030˝ (0.75mm) 7,000psi (483bar)* AT1538 0.040˝ (1.00mm) 5,000psi (345bar)* AT1537 0.055˝ (1.40mm) 500psi ( 34bar)* AT1534 0.062˝ (1.60mm) 4,000psi ( 276bar)* AT1544 0.080˝ (2.00mm) 3,000psi ( 207bar)* AT1545 0.010˝ (0.25mm) 7,000psi (483bar)* AT1546 0.020˝ (0.50mm) 7,000psi (483bar)* AT1547 0.030˝ (0.75mm) 7,000psi (483bar)* AT1540 0.042˝ (1.05mm) 5,000psi (345bar)* AT1539 0.055˝ (1.40mm) 500psi ( 34bar)* AT1579 0.025˝ ( 65μm ) 5,000psi (345bar)* AT1578 0.035˝ ( 90μm ) 5,000psi (345bar)* AT1576 0.050˝ ( 125μm ) 5,000psi (345bar)* AT1577 0.070˝ ( 175μm ) 5,000psi (345bar)* AT1575 0.080˝ ( 200μm ) 5,000psi (345bar)* AT1580 0.090˝ ( 230μm ) 5,000psi (345bar)* AT1581 0.100˝ (0.25mm) 5,000psi (345bar)* AT1568 0.150˝ (0.40mm) 5,000psi (345bar)* AT1569 0.200˝ (0.50mm) 5,000psi (345bar)* 1/16” OD x 5’ L 1/8” OD x 5’ L 1.8 mm OD x 5’ L 1/32” OD x 5’ L Tubing Holders Tubing Holders For Polymer Tubing Cat.No AP•740 90°Tubing Holder for 1/16˝ OD tubing, polystyrene AP•741 180°Tubing Holder for 1/16˝ OD tubing, polystyrene AP•815 90°Tubing Holder for 1/8˝ - 5/16˝ OD tubing, PVT Tubing Cutters Tubing Cutters For Polymer Tubing Cat.No. Standard Polymer Tubing Cutter* for 1/16˝ and 1/8˝ AA•327 OD tubing Large Bore Polymer Tubing Cutter* for 3/16˝ - 5/16˝ AA•329 OD tubing Capillary Polymer Tubing Cutter* for 360μm- 1/32˝ AA•350 OD tubing Includes(1)F•262x10-pack of sleeves Replacement Blades for A •327, A •329and A •350 AA•328 5-pk Replacement Sleeves for A •350,0.0155˝ID,Green, for cutting 360μm OD tubing 10-pk Alternate Sleeves for A •350,0.021˝ID,Natural, for AF•262x AF•264x cutting 510μm OD tubing 10-pk Alternate Sleeves for A •350,0.033˝ID,Blue, for AF•267Bx cutting 1/32˝ OD tubing 10-pk Precision Fused Silica Tubing Cutter AFS•315 Maintenance Kit for FS•315 AFS•315•02 HPLC Injector and Sample Loop Sample Injector Type Description Cat.No. Rheodyne 7725 Injector Standard Analytical Sample Injector; Stainless steel INJ7725 Rheodyne 9725 Injector Standard Analytical Sample Injector; Peek INJ9725 Rheodyne 3725 Injector Preparative Sample Injector INJ3725 Sample Loop Type Cat.No. 5μL Stainless Steel LPS0005SS 5μL Peek LPS0005PK 20μL Stainless Steel LPS0020SS 20μL Peek LPS0020PK 50μL Stainless Steel LPS0050SS 50μL Peek LPS0050PK 100μL Stainless Steel LPS0100SS 100μL Peek LPS0100PK 1mL Stainless Steel LPS1000SS 1mL Peek LPS1000PK 5mL Stainless Steel LPS5000SS 10mL Stainless Steel LPS0000SS Automated Switching Valve z Used for 2D-LC or on-line SPE/LC z Editable valve diagram. z Flexible in choosing valve number and valve type. z The valve types can be 2-position/6-port; 2-position/8-port; 2-position/10- port; 6-position or 10 position. z One module can be installed with 1 or 2 valves. Two modules can be used together to z make a 4-valve platform or be sued as two independent modules. Ordering Information Type Cat.No. LC-04SP Valve System ASV0002-0 Automatic Column Selector z Connect up to 6 HPLC columns z Controllable by both panel keys and computer z Easy key operation for setting method and sequence z Compact design and easy access to columns z Compatible with any HPLC z Compatible with other LC-04SP valves Cat.No.: AST-006 HPLC Column Heater Technical specification Cat.No. CC-100 Dimensions (H×W×D) 510mm×110mm×65mm Operating Temperature Above 5℃~100℃ Temperature Accuracy ±0.1℃ Compatible Column Quantity and Length 2×300mm Power 220V/50Hz/1A Weight 4Kg UV Lamps Agela Technologies offers UV lamps of the same or better quality as a low cost replacement for many of those manufactured by original HPLC manufacturers, such as Waters, Agilent, Varian, Shimazu and Perkin-Elmer. Original Instrument Part Number Agela Lamps Part Number Type of Lamps l037 AL-610 W l040A,1040M ALH-10 D2 1046 AL-890 P/Xe l047A AL-610 W 79853A AL-295 D2 79853C,79854A ALH-10 D2 79880A,7988lA ALH-l0 D2 8450A ALH-l6 D2 8450A ALH-855 W 8451A ALH-11 D2 8452A ALH-12 D2 8453A,8453E ALH-15 D2 8453A ALH-13X2 D2 8453A AL-850 mf G1306A ALH-10 D2 G13l4A ALH-14 D2 Gl315A&B,Gl365A&B ALH-13 D2 Gl315A&B,Gl365A&B ALH-13X2 D2 Gl3l5A&B,Gl365A&B AL-850 W 79875A Gl32l A P/Xe Gl362 W HP3D/CE ALH-l4 D2 Series I&II ALH-10 D2 Shimadzu Agela Lamps Part Type of Number Lamps SPD-7A, 7AV AL-305 D2 SPD-10A, 10 AV, 10AVP ALH-80 D2 SPD-10 AV, 10AVP AL-830 W SPD-M6A, M10A, M10AV ALH-81 D2 SPD-M6A, M10A AL-935 W SPD-M10AV AL-830 W SPD-M10AVP ALH-80 D2 SPD-M10AVP AL-835 W Original Instrument Part Number SPD-M1A Varian Original Instrument Part Agela Lamps Part Type of Number Number Lamps AA200,275,300 AL-230 D2 AA400,600,640 AL-230 D2 AA775,800,875 AL-230 D2 AA975,l275,l475 AL-230 D2 AA3000 AL-230 D2 DMS90 Eclipse FL-l,2 P/Xe ALH-910 P/Xe PDA,1 ALH-80 D2 PDA-2 ALH-80 D2 LC-5000,5500 PDA-2 W Pro Star ALH-950 P/Xe pro Star 310 AL-305 D2 Pro Star 320 ALH-950 P/Xe Pro Star 330 ALH-53 D2 Pro Star 340,345 ALH-40 D2 Pro Star 360 ALH-910 P/Xc Pro Star 363 AL-800 Xe Pro Star 364 P/Xe Spectra A10,20,30,40 AL-230 D2 Star 9050 AL-305 D2 1JV•1,lA ALH-950 P/Xe UV50,100,200 AL-305 D2 VIsta 5500 AL-305 D2 Waters Agela Lamps Part Type of Number Lamps 420 AL-770 Hg 440,44l AL-820 Hg 441 AL-720 Cd 441 AL-7l5 Zn 450 ALHA-l D2 Lamp Ass’y 450 ALH-l D2 Replacement 470,474 AL-800 Xe 480,48l AL-205 D2 484 ALH-3O D2 486 ALH-3l D2 990,99l,994 ALHA-34 D2 Lamp Ass’y 990,991,994 ALH-34 D2 Replacement 996 ALH-33 D2 2475 ALH-925 Xe 2487,2488 ALH-36X2 D2 2996 ALH-33 D2 LC Module l/3455l System ALH-3l D2 Original Instrument Part Number 40l,403,404 SPE Accessories and Supplies SPE Vacuum Manifolds SPE Vaccum Manifold for SPE sample preparation, filtration and elution are available in 12 and 24 port configurations. These manifolds permit consistent extraction and filtration results. Multiple sample processing with these manifolds consist of a clear glass chamber and lid, to which a vacuum is applied to draw solvents and sample through an SPE column, cartridge, or disk. The lid is CNC machined, solvent resistant, low extractable virgin polypropylene. The lid is autoclavable, and will not wrap. The female Lure inlets and male Lure outlets are molded of pure polypropylene. Adjustable racks placed in the glass chamber will accommodate a variety of sample collection vessels, including test tubes, autosampler vials, volumetric flasks, and Erlenmeyer flasks. Eluants are deposited directly into the collection vessel of choice via polypropylene, or optional stailness steel or Teflon needles. Ordering Information Type Cat.No. 12 port Model VM0012 24 port Model VM0024 96well plate Model VM0096 Multipurpose SPE Work-station This is specially designed to replace conventional SPE manifolds and solvent evaporators by an integrated and versatile workstation. It features: z Ease for operation: easier to change the collection tubes z Flexibility: can be used for vacuum or positive pressure mode; z more choices for tube size z Multifunction: SPE processing and solvent evaporation z Solid: made of aluminum alloy instead of fragile glass z Compatible with automated liquid handling systems Cat.No.: MST-001 SPE-1 Automated Processing Station z Designed for sample preparation in trace analysis of food and environmental samples. z Process up to 6 samples per batch without attendance. z Up to 5 solvents can be used for column conditioning and multi step elution. z Two fractions can be collected for each sample. z Accommodate SPE cartridges and traditional cleanup columns. z Exhaustive sample injection. z Easy operation with only 7 buttons. z Small footprint and computer-free operation Cat.No.: APT-001 Positive Pressure SPE Work-station Ordering Information Cat.No. Description Qty/Pk APSP-48 Positive Pressure Processor-48 Position 1 APSP-22 Rack for 1 ml SPE Columns 1 APSP-23 Rack for 3 ml SPE Columns 1 APSP-24 Rack for 6 ml SPE Columns 1 APSP-19 Collection Tube Rack, 12 x 75 mm Tubes 1 APSP-20 APSP-21 APSP-25 Collection Tube Rack, 13 x 100 mm Tubes Collection Tube Rack, 16 x 100 mm Tubes Collection Vial Rack, 12 x 32 mm Auto-Sampler 1 1 1 APSP-26 Waste Bin 1 APSP-27 48-Column Sealing Gasket 1 APSP-28 Gas Supply Adapter 1 Robotic SPE Work-station z 24 well to 96 well reformatting z 96 and 384 well dispensing z Automated Tip changing z 96 well and 384 well liquid level sensing z 12 decks for large sample processing Cat.No.: RST-0096 Solvent Evaporator Product Features z Combination of heating and vacuum for speedy evaporation of a variety of solvents at relative lower temperature (safe, faster and better for unstable compounds) z Simple operation, no programming set-up needed z Adjustable gas pressure and flow z Multi-size block interchangeable, accepts tubes OD from 11 to 29mm z Optional automatic shutoff, for safe and fast parallel enrichment of various samples z Small footprint, only 18(W)x16(D)inch bench area z Broad customization configurations z Economic and reliable 1.Height post 2.Vacuum vent 3.Needle piercing gas manifold 4.Sample tubes 5.Temperature controller 6.System flow controller Technical Specifications: Dimension 18(W)x20(H)x16(D) inch 45(W)x50(H)x40(D)cm Weight 20lb/10kg Power 90-120VAC, 50-60Hz, 500VA Mount Bench stand Working environment 4 to 40°C, Humidity <80% Well plate dimension 5(W)x4.5(D)x2(H)inch127(W)x110(D)x50(H)mm Number of Well Plate 12, 15, 30, 48 Tube OD 11-29mm Tube length 125-200(mm) Temperature RT-150°C Temperature accuracy +-1°C Gas pressure 30psi (2bar) max Gas flow 0-5liter/min Needle Stainless steel, 1.6(OD)x150(L)mm Gas/vacuum connection fitting Hose barb 1/8 flow port Auxiliary vacuum 5-12psi, 200-700mmHg Ordering Information Description Cat.No. Solvent evaporator, including a multi-needle manifold, inert gas flow module, heater & controller, 120VAC, 1year limited warranty. GD-101(regular system) Order multi-well blocks and manifold plates separately! Solvent evaporator, including individual flow controlled needle manifold, heater & controller, 120VAC, 1year limited warranty GD-102-xx, xx is number of wells of block Order multi-well blocks and manifold plates separately! Solvent evaporator, 48 or 96well plate format, including purge manifold, GD-103-48 inert gas heating & controller, 120VAC, 1year limited warranty GD-103-96 Empty Columns and Accessories Ordering Information Description Tube Part No. Frit Part No. 1mL, 100/pk 050901 050911 3mL, 100/pk 050903 050913 6mL, 100/pk 050906 050916 1mL, 3mL, 6mL column,12/pk 050909 Pipettes and Accessories Mechanical Pipette (Fixed Volume) Cat No. Volume (μL) A722001 5 A722004 10 A722010 20 A722015 25 A722020 50 A722025 100 A722030 200 A722035 250 A722040 500 A722045 1000 A722050 2000 A722055 5000 Mechanical Pipette (AdjustableVolume) Single Channel Pipette Cat No. Volume (μL) Increment (μL) A720005 0.1-2.5 0.05 A720000 0.5-10 0.1 A720020 5-50 0.5 A720080 2-20 0.5 A720050 10-100 1 A720070 20-200 1 A720030 50-200 1 A720060 100-1000 5 A720040 200-1000 5 A720110 1000-5000 50 Cat No. Volume (μL) Increment (μL) A720210 0.5-10 0.1 A720220 5-50 0.5 A720240 50-300 5 Cat No. Volume (μL) Increment (μL) A720310 0.5-10 0.1 A720320 5-50 0.5 A720340 50-300 5 8 - Channel Pipette 12 - Channel Pipette Pipette Tips Cat No. Qty AD781348 FT10μL AD781349 FT10μL AD780006 FT300μL AD780007 FT300μL AD780019 FT1000μL AD780020 FT1000μL AD780046 FT1200μL GC Accessories and Supplies Septa Septa BTO z Extended temperature range, low-bleed z Maximun temperature 400℃ z Virtually eliminates injection-port sticking z Preconditioned packaged in glass to prevent contamination z Each batch GC-FID tested. z Ideal for use with low-bleed, “Mass Sepc” capillary columns Cat.No. Description B02-1002 Septa BTO 5mm Center guide (50/pk) B02-1040 Septa BTO 3/8" (9.5mm) (50/pk) B02-1031 Septa BTO 11.5mm Center guide (50/pk) B02-1001 Septa BTO 11mm (7/16") Center guide (50/pk) B02-1032 septa BOT 17mm,Center guide Advanced Green 3 z True low-bleed, high temperature green septum. z Maximum temperature 400 ℃ Cat.No. Description B02-1006 Septa AG3 5mm Center guide (50/pk) B02-1005 Septa AG3 11mm (7/16") Center guide (50/pk) B02-1041 Septa AG3 3/8" (9.5mm) (50/pk) Injection Port Liners Organosilane deactivated borosilicate glass (quartz where notes). Guaranteed inertness for phenols, organic acids and bases. Glass wool is also deactivated. These capillary injection port liners provide a clean, non-adsorptive surface for your samples. Regular replacement of the liner protects your capillary columns from potentially harmful non-volatiles that might otherwise deposit on your columns. For Agilent Capillary GC Instruments Cat.No. Description Qty. B02-3004 Liner, 4 mm,79mm length, Single Taper w/ Sil Wool 1/pk B02-3005 Liner, 4 mm,79mm length, Single Taper w/ Sil Wool 5/pk B02-3007 Liner, 4 mm,79mm length, Single Taper w/ Sil Wool 10/pk B02-3008 Liner, 4 mm,79mm length, Double Taper 1/pk B02-3009 Liner, 4 mm,79mm length, Double Taper 5/pk B02-3011 Liner, 4 mm,79mm length, Double Taper 10/pk B02-3012 Liner, 4 mm,79mm length, Single Taper 1/pk B02-3013 Liner, 4 mm,79mm length, Single Taper 5/pk B02-3015 Liner, 4 mm,79mm length, Single Taper 10/pk B02-3019 Liner, 4mm,79mm length, with Silanized Wool 1/pk B02-3020 Liner, 4mm,79mm length, with Silanized Wool 5/pk B02-3022 Liner, 4mm,79mm length, with Silanized Wool 10/pk B02-3030 Liner, 2 mm,79mm length, Splitless, Glass 1/pk B02-3031 Liner, 2 mm,79mm length, Splitless, Glass 5/pk B02-3032 Liner, 2 mm,79mm length, Splitless, Glass 10/pk B02-3033 Liner, 2 mm,79mm length Splitless, Quartz 1/pk B02-3034 Liner, 2 mm,79mm length Splitless, Quartz 5/pk B02-3036 Liner, 2 mm,79mm length Splitless, Quartz 10/pk For Perkin-Elmer Capillary GCs Cat.No. Description Qty. Cat.No. Description Qty. B02-3201 Liner, 4 mm Split, 92mm length ,Autosystem for PerkinElmer GC 1/pk B02-3202 Liner, 4 mm Split, 92mm length ,Autosystem for PerkinElmer GC 5/pk B02-3203 Liner, 4 mm Split, 92mm length ,Autosystem for PerkinElmer GC 10/pk B02-3204 Liner, 4 mm Split,92mm length Autosystem w/ Wool for PerkinElmer (ea) 1/pk B02-3205 Liner, 4 mm Split,92mm length Autosystem w/ Wool for PerkinElmer (ea) 5/pk B02-3206 Liner, 4 mm Split,92mm length Autosystem w/ Wool for PerkinElmer (ea) 10/pk B02-3207 Liner,2mm Splitless,92mm length, Autosystem for PerkinElmer GC 1/pk B02-3208 Liner,2mm Splitless,92mm length, Autosystem for PerkinElmer GC 5/pk B02-3209 Liner,2mm Splitless,92mm length, Autosystem for PerkinElmer GC 10/pk B02-3210 Liner,100mm, Dimple Spliter for PerkinElmer GC 1/pk B02-3211 SLiner,100mm, Dimple pliter for PerkinElmer GC 5/pk B02-3212 Liner,100mm, Dimple Spliter for PerkinElmer GC 10/pk For Varian Capillary GCs Cat.No. Description Qty. B02-3103 4 mm Open Split w/ Sil. Wool for Varian 1075/1077 1/pk B02-3104 4 mm Open Split w/ Sil. Wool for Varian 1075/1077 5/pk B02-3105 4 mm Open Split w/ Sil. Wool for Varian 1075/1077 10/pk B02-3112 Liner, Frit Split for Varian 1075/1077 1/pk B02-3113 Liner, Frit Split for Varian 1075/1077 5/pk B02-3114 Liner, Frit Split for Varian 1075/1077 10/pk B02-3115 Liner, 4 mm Open Split, for Varian 1075/1077 1/PK B02-3116 Liner, 4 mm Open Split, for Varian 1075/1077 5/PK B02-3117 Liner, 4 mm Open Split, for Varian 1075/1077 10/PK B02-3118 Liner, 74mm length, Splitless, Glass for Varian 1075/1077 (ea) 1/pk B02-3119 Liner, 74mm length, Splitless, Glass for Varian 1075/1077 (ea) 5/pk B02-3120 Liner, 74mm length, Splitless, Glass for Varian 1075/1077 (ea) 10/pk Ferrules Vespel Ferrules-Sold in Packages of 10 z Upper temperature limit : 350℃ z 100% high-temperature DuPont polyimide z Fairly hard; tends to seal permanently to the column Straight Ferrules-for tubing with ODs as listed Cat.No. 1/16" ferrules B02-2125 1/8" ferrules B02-2133 1/4" ferrules B02-2141 Capillary Column Ferrules 1/16" to 0.3mm ferrules B02-2126 1/16" to 0.4mm ferrules B02-2127 1/16" to 0.5mm ferrules B02-2128 1/16" to 0.8mm ferrules B02-2129 1/16" to 1.0mm ferrules B02-2130 1/16" to 1.2mm ferrules B02-2131 1/16" to 0.4mm -Agilent style B02-2012 1/16" to 0.5mm -Agilent style B02-2013 1/16" to 0.8mm -Agilent style B02-2014 Reducing Ferrules 1/8" to 0.4mm Vespel B02-2135 1/8" to 0.5mm Vespel B02-2136 1/8" to 0.8mm Vespel B02-2137 1/8" to 1/16" Vespel B02-2138 1/4" to 1/16" ferrules B02-2143 1/4" To 1/8" ferrules B02-2144 Graphite Ferrules—Sold 10/pack Except as Noted z Upper temperature limit : 450℃ z High-purity Graphite; Preferred for capillary GC use z Ideal for glass-to-metal connections; doesn't stick to glass z Reusable if not over-tightened Ordering Information Cat.No. Description Straight Ferrules-for tubing with ODs as listed B02-2101 1/16" Graphite Ferrule B02-2109 1/8" Graphite Ferrule B02-2116 1/4" Graphite Ferrule Short Ferrules for Agilent Inlets B02-2001 1/16"to 0.4mm Graphite Ferrule B02-2002 1/16"to 0.5mm Graphite Ferrule B02-2003 1/16"to 0.8mm Graphite Ferrule B02-2004 1/16"to 1.0mm Graphite Ferrule Capillary Column Ferrules B02-2102 1/16"to 0.4mm Graphite Ferrule B02-2103 1/16"to 0.5mm Graphite Ferrule B02-2104 1/16"to 0.8mm Graphite Ferrule B02-2105 1/16"to 1.0mm Graphite Ferrule B02-2106 1/16"to 1.2mm Graphite Ferrule B02-2110 1/8" to 0.4 mm Graphite Ferrule B02-2111 1/8" to 0.5 mm Graphite Ferrule B02-2112 1/8" to 0.8 mm Graphite Ferrule B02-2113 1/8" to 1/16" Graphite Ferrule B02-2117 1/4" to 1.0 mm Graphite Ferrule B02-2118 1/4" to 0.4 mm Graphite Ferrule B02-2119 1/4" to 0.5 mm Graphite Ferrule B02-2120 1/4" to 0.8 mm Graphite Ferrule B02-2121 1/4" to 1/16" Graphite Ferrule B02-2122 1/4" to 1/8" Graphite Ferrule B02-2123 1/4" to 6.0 mm Graphite Ferrule B02-2124 1/4" to 4.0 mm Graphite Ferrule Reducing Ferrules Vespel/Graphite Ferrules –Sold in Packages of 10 z Upper temperature limit : 400℃ z Made from quality DuPont polyimide/graphite blend z Recommended for GC/MS interface applications Ordering Information Cat.No. Description Straight Ferrules-for tubing with ODs as listed B02-2145 1/16" V/G Ferrules B02-2153 1/8" V/G Ferrules B02-2160 1/4" V/G Short Ferrules for Agilent Inlet B02-2005 1/16" to 0.4mm V/G Ferrules B02-2006 1/16" to 0.5mm V/G Ferrules B02-2007 1/16" to 0.8mm V/G Capillary Column Ferrules B02-2146 1/16" to 0.4mm V/G Ferrules B02-2147 1/16" to 0.5mm V/G Ferrules B02-2148 1/16" to 0.8mm V/G B02-2149 1/16" to 1.0mm V/G Ferrules B02-2150 1/16" to 1.2mm V/G B02-2154 1/8" to 0.4mm V/G Ferrules B02-2155 1/8" to 0.5mm V/G Ferrules B02-2156 1/8" to 0.8mm V/G B02-2157 1/8" to 1/16" V/G Ferrules B02-2161 1/4" to 0.4mm V/G B02-2162 1/4" to 0.5mm V/G B02-2163 1/4" to 6.0 mm V/G Ferrules B02-2164 1/4" to 0.8mm V/G Ferrules B02-2166 1/4" to 1/16" V/G Ferrules Reducing Ferrules B02-2167 1/4" to 1/8" V/G Teflon Ferrules –Sold in Packages of 10 z Upper temperature limit : 250℃ z 100% Teflon ;completely inert Ordering Information Cat.No. Description Straight Ferrules-for tubing with ODs as listed B02-2169 1/16" Teflon B02-2176 1/8" Teflon B02-2182 1/4" Teflon Capillary Column Ferrules B02-2170 1/16" to 0.3mm Teflon B02-2171 1/16" to 0.4mm Teflon B02-2172 1/16" to 0.5mm Teflon B02-2173 1/16" to 0.8mm Teflon B02-2174 1/16" to 1.0mm Teflon B02-2175 1/16" to 1.2mm Teflon B02-2177 1/8" to 0.4mm Teflon B02-2178 1/8" to 0.5mm Teflon B02-2179 1/8" to 0.8mm Teflon B02-2180 1/8" to 1/16" Teflon B02-2183 1/4" to 6mm Teflon B02-2185 1/4" to 1/16" Teflon B02-2186 1/4" To 1/8" Teflon B02-2187 1/4" to 3/16" Teflon Reducing Ferrules Column Scribe Used to cut capillary tubing. Simply pull one smooth edge of the hard ceramic scribe (tilted about 45 degrees) across the column to lightly score the fused silica .Bend the column opposite the score and the column separate cleanly. Ordering Information Cat.No. Description B02-1006 Column Scribe,10/pk 1/32” Ultra Low Mass External Unions For capillary tubing 0.1 to 0.32mm I.D. It has very low mass and can be hand-tightened to seal .Use only with 1/32” fused silica adapters; metal ferrules cannot be used. Ordering Information Cat.No. Description B02-4001 1/32" Union,Bore 0.25mm B02-4002 1/32" Union,Bore 0.50mm B02-4003 1/32" Union,Bore B02-4004 1/32" 1/32" Fused Silica Tubing Adapter Tubing o.d.<0.25mm B02-4005 1/32" Fused Silica Tubing Adapter Tubing o.d. 0.25-0.4mm B02-4006 1/32" Fused Silica Tubing Adapter Tubing o.d.0.5mm B02-2171 1/16" to 0.4mm Teflon B02-2172 1/16" to 0.5mm Teflon B02-2173 1/16" to 0.8mm Teflon B02-2174 1/16" to 1.0mm Teflon B02-2175 1/16" to 1.2mm Teflon Filtration Products High Quality – All of our products are manufactured by ISO 9001 registered manufacturers and are guaranteed to meet our published specification. Best Value – Our list prices are significantly lower than most brand name prices in the market. Syringe Filters Ordering Information Mixed cellulose (acetate and nitrate) syringe Qty. Cat No. 0.2μm 100 AS011320 0.45μm 100 AS011345 0.2μm 100 AS012520 0.45μm 100 AS012545 0.2μm 100 AS011320-G 0.45μm 100 AS011345-G 0.2μm 100 AS012520-G 0.45μm 100 AS012545-G 0.2μm 100 AS021320 0.45μm 100 AS021345 0.2μm 100 AS022520 0.45μm 100 AS022545 0.2μm 100 AS021320-P 0.45μm 100 AS021345-P 0.2μm 100 AS022520-P 0.45μm 100 AS022545-P 0.2μm 100 AS031320 0.45μm 100 AS031345 0.2μm 100 AS032520 0.45μm 100 AS032545 0.2μm 100 AS031320-P 0.45μm 100 AS031345-P 0.2μm 100 AS032520-P 0.45μm 100 AS032545-P 0.2μm 100 AS041320 0.45μm 100 AS041345 0.2μm 100 AS042520 0.45μm 100 AS042545 1μm 100 AS042501 filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with glass prefilter 25mm Syringe Filters with glass prefilter Nylon syringe filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with PP prefilter 25mm Syringe Filters with PP prefilter PVDF syringe filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with PP prefilter 25mm Syringe Filters with PP prefilter PTFE syringe filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with PP prefilter 25mm Syringe Filters with PP prefilter 5μm 100 AS042505 0.2μm 100 AS041320-P 0.45μm 100 AS041345-P 0.2μm 100 AS042520-P 0.45μm 100 AS042545-P 1μm 100 AS042501-P 5μm 100 AS042505-P Ordering Information Polyethersulfone (PES) syringe filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with glass prefilter 25mm Syringe Filters with glass prefilter Qty Cat No. 0.2μm 100 AS051320 0.45μm 100 AS051345 0.2μm 100 AS052520 0.45μm 100 AS052545 0.2μm 100 0.45μm 100 0.2μm 100 0.45μm 100 0.2μm 100 AS061320 0.45μm 100 AS061345 0.2μm 100 AS062520 0.45μm 100 AS062545 0.2μm 100 0.45μm 100 0.2μm 100 0.45μm 100 AS051320G AS051345G AS052520G AS052545G Regenerated cellulose (RC) syringe filters 13mm Syringe Filters 25mm Syringe Filters 13mm Syringe Filters with glass prefilter 25mm Syringe Filters with glass prefilter AS061320G AS061345G AS062520G AS062545G The Syringe Filters’ Specifications Description MCM Nylon PVDF Diameter of Pore size Pressure Bubble Point Water speed Air speed Effective the filter(mm) (μm) rating(bar) rating(bar) (ml/min/cm2) (L/min/cm2) filter area(cm2) 13 0.22 7 3.52 18 0.65 13 0.45 7 2.2 60 0.65 25 0.22 5 3.52 18 3.9 25 0.45 5 2.2 60 3.9 13 0.22 7 2.80 25 0.65 13 0.45 7 2.5 75 0.65 25 0.22 5 2.8 25 3.9 25 0.45 5 2.5 75 3.9 13 0.22 7 1.20 15 16 0.65 13 0.45 7 0.56 35 20 0.65 25 0.22 5 1.20 15 16 3.9 25 0.45 5 0.56 35 20 3.9 PTFE 13 0.22 7 1.00 24 5 0.65 13 0.45 7 0.63 60 8 0.65 25 0.22 5 1.00 24 5 3.90 25 0.45 5 0.63 60 8 3.90 96 Well Filtration Plates and Collection Plates Ordering Information Type Vol Qty Cat.No. Filtration plate 2mL 10 FTPP2002-01 PP frits 20μm 1mL 10 FTPP2001-01 Filtration plate 2mL 10 FTPF4502-01 PTFE membrane 0.45μm 1mL 10 FTPF4501-01 Filtration plate packed with 2mL 10 FTFT1002-01 earth diatomaceous 100mg 1mL 10 FTFT1001-01 Protein precipitation plates 2mL 10 PPPC1002-01 and collection 1mL 10 PPPC1001-01 2mL 10 CLCM0002-01 1mL 10 CLCM0001-01 — 10 CLCM9600-0 Collection plate, round bottom 96 well cap mats Membrane Filters Material: cellulose acetate, nylon Pore size: 0.45μm Filter size: 13mm, 25mm, 50mm Customized sizes available upon request Ordering Information Material Diameter(mm) Qty Cat. No. Cellulose Acetate 13 100/pk AM011345 25 100/pk AM012545 50 100/pk AM015045 13 100/pk AM021345 25 100/pk AM022545 50 100/pk AM025045 Nylon Glass Filtration System The system includes a borosilicate glass funnel, a sintered borosilicate glass membrane support base on neck, aluminum clamp and borosilicate glass filter flask. It can be used with or without membrane depending on the application requirement to filtrate organic or aqueous solution. It is also used for liquid degassing Funnel volume: 300mL, 500mL Pore size of the glass support: 10μm Flask volume: 1000ml, 2000mL Ordering Information Funnel Volume (mL) Flask Volume (mL) Qty Cat. No. 300 1000 ea AM3100 300 2000 ea AM3200 500 1000 ea AM5100 500 2000 ea AM5200 Chemical Resistance Guide for Membranes Chemical Mixed Cellulose Acetate/nitrate Regenerate Cellulose Nylon PTEE 1-hexanol + + + + Acetic acid,10%&25% 0 + - + Acetone - + + + Acetonitrile - + + - Aliphatic hydrocarbon + + + + Ammonia,1M + + + + Aromatic hydrocarbon + + N/A + Benzene + + + + Boric acid + + 0 + CTC 0 + - + Carboxylic acid + + - + Chloroacetic acid - 0 - + Chloroform - + + 0 Cyclohexane 0 + + + Cyclohexanol + + + + Diethyl ether 0 + + 0 Dimethyl formamide - 0 + + DMSO - 0 N/A + Alcohol=<98% + + + + Acetic ether - + + + Vinyl chloride 0 + + + Ethylene glycol + + + + Formic acid, 25% 0 + - + N-hexane + + + + Hydrochloric acid,25% - + - + Isopropyl alcohol + + + + Methanol + + 0 + Nitrous acid,25% 0 + - + Pentane + + + + Phosphoric acid,25% + + 0 + Phosphoric acid,45% 0 0 0 + KOH,1M - 0 - + Water solution of inorganic salt + + + + NaOH,1M 0 - - + Acetylene tetrachloride 0 + 0 + THF - + + 0 Toluene + + + + TCA,10% - - 0 + Trichloro ethane 0 + 0 + Trichloroethylene 0 + 0 + Dimethyl benzene + + + The mark represent: “+” = chemical resistance; “0” = limited chemical resisitant; “-” = no chemical resistance ; N/A= no data. + Vials and Caps Agela Technologies Inc offers a number of high quality vials, caps, seals and crimping tools. Most of them are manufactured in Europe and meet the high standard of the chromatographic applications. The difference of our offering from many other brand name venders is the cost to you. We offer lower price for the same products as many brand name’ s due to our lean cost structure and we provide personal assist to you to select right products 2 mL 12 x 32 mm Screw Neck Vials and Caps Vials Cat. Cat. No.(100/pk) No.(1000/pk) Clear AV1000-0 AV1000-1 Std Amber AV1010-0 AV1010-1 Screw neck vials, graduated Std Clear AV1001-0 AV1001-1 Screw neck vials, graduated Std Amber AV1011-0 AV1011-1 Screw neck vials short Clear AV1100-0 AV1100-1 Screw neck vials, graduated short Clear AV1101-0 AV1101-1 Screw neck vials, graduated short Amber AV1111-0 AV1111-1 Screw neck vials Wide mouth 10/425 Clear AV1200-0 AV1200-1 Screw neck vials, graduated Wide mouth 10/425 Clear AV1201-0 AV1201-1 Screw neck vials, graduated Wide mouth 10/425 Amber AV1211-0 AV1211-1 Description Thread Color Screw neck vials Std Screw neck vials Caps and Septa Description Thread Cat. No.(100/pk) Cat. No.(1000/pk) Screw cap Std AV2000-0 AV2000-1 Screw cap short AV2100-0 AV2100-1 Screw cap (wide mouth) Wide mouth (10/425) AV3100-0 AV3100-1 2 mL 12 x 32 mm Crimp Neck Vials and Caps Vials Cat. Cat. No.(100/pk) No.(1000/pk) Clear AV5000-0 AV5000-1 Narrow mouth Amber AV5010-0 AV5010-1 Crimp neck vials Wide mouth Clear AV5001-0 AV5001-1 Crimp neck vials, graduated Narrow mouth Clear AV5100-0 AV5100-1 Crimp neck vials, graduated Narrow mouth Amber AV5101-0 AV5101-1 Crimp neck vials, graduated Wide mouth Clear AV5111-0 AV5111-1 Crimp neck vials Wide mouth Amber AV5200-0 AV5200-1 Description Thread Color Crimp neck vials Narrow mouth Crimp neck vials Caps and Septa Cat. Description Thread Cat. No.(100/pk) Crimp cap Narrow mouth AV6000-0 AV6000-1 Crimp cap Wide mouth AV6100-0 AV6100-1 No.(1000/pk) Plastic Vials (micro-vials for LC-MS autosamplers) Description Material Vol. Cat. No. Snap ring micro-vial32×11.6mm PP 300μL AV0003-P Snap ring micro-vial32×11.6mm TPX 300μL AV0003-T Snap Cap PP — AV0003-C Septa Silicone/PTFE — AV0003-S
Similar documents
Bonna-Agela Technologies
great interfacial kinetics for high efficiency. A line of stationary phases includes C18, C8, Phenyl and NH2. Characteristics: Metal Impurity<30ppm; Pore Size: 100Å; Specific: Surface Area: 380m2/g...
More informationTechnologies - MZ-AT
time of ordering will be guaranteed. The general payment term is net 30 days, F.O.B., Newark, Delaware,USA. However we reserve the right to ask for prepayment if customers' account information is n...
More information- Aela Agela Technologies
The prices are in effect at the time of printing. BonnaAgela Technologies reserves the right to change the prices without notice, though we do our best to provide our customers with advance notice....
More informationPurification Products
time of ordering will be guaranteed. The general payment term is net 30 days, F.O.B., Newark, Delaware,USA. However we reserve the right to ask for prepayment if customers’ account information is n...
More information- Aela Agela Technologies
CHEETAHTM HP 100 is an automated high pressure preparative LC system from Bonna-Agela Technologies. It is an integrated system featuring binary gradient pump, UV detector and fraction collector. Th...
More information