Recycling Passport

Transcription

Recycling Passport
Recycling Passport
WEEE Selective Treatment
WEEE Category:
Manufacturer:
Product Family
Model Name:
Part Numbers:
IT and Telecommunications Equipment
Plasmon
Optical Library
Enterprise D Library
D525. D875, D1525, D2175
NOTE:
This WEEE Selective Treatment document answers WEEE European directive 2002/96/EC
(Waste Electrical and Electronic Equipment). It provides information for treatment facilities
and is not a disassembly instruction.
Lead, Mercury, Cadmium, Hexavalent Chromium, polybrominated biphenyls (PBB) or polybrominated
diphenylethers (PBDE) are included in this document only if their level exceeds the values below.
Materials (1) (2)
Pb – Lead
Cd – Cadmium
Hg – Mercury
CrVI – Hexavalent Chromium
PBB – Polybrominated Biphenyls
PBDE – Polybrominated Diphenylethers
< 0.1%
< 0.01%
< 0.1%
< 0.1%
< 0.1%
< 0.1%
(1) Maximum concentration value (by weight) in any homogenous material
(2) These values were adopted from the Commission Decision 2005 / 618 / EC – 18th August 2005
The information presented in this document does not form part of any quotation or contract, is
believed to be accurate and reliable, and is offered at no charge without notice. No liability will
be accepted by the publisher for any consequence of its use. Publication thereof does not
convey nor imply any license under patent, or other industrial or intellectual property rights.
Plasmon Data Limited
Whiting Way
Melbourn
Nr. Royston, Hertfordshire SG8 6EN
United Kingdom
Tel: +44 (0)1763 262963
Fax: +44 (0)1763 264444
WEEE Selective Treatment – Enterprise D Library
Plasmon LMS
4425 ArrowsWest Drive
Colorado Springs
CO 80907
United States
Tel: +1 719-593-7900
Fax: +1 719-593-4271
1 of 6
WEEE
Selective
Treatment
Category
Type/Materials
Substances
Check ONLY if
substance is
present
1
Capacitors containing Polychlorinated biphenyls (PCB) or
Polychlorinated terphenyls (PCY/PCT)
2
Components containing Mercury - e.g. switches, circuit
breakers, lamps
3
Batteries
4
Printed Circuit Boards - Area greater than 10 square
centimetres
5
Toner cartridges from printers
6
Plastic containing brominated flame retardants
7
Components containing Asbestos
8
Cathode ray tubes
9
Refrigerants - Chlorofluorocarbons (CFC),
Hydrochlorofluorocarbons (HCFC) or hydrofluorocarbons
(HFC), and hydrocarbons (HC)
10
Gas discharge lamps
11
Liquid crystal displays (together with their casing where
appropriate) of a
surface area greater than 100 square centimetres and all backlighted with gas discharge lamps
12
External electrical cables
13
Components containing refractory ceramic fibres
14
Components containing radioactive substances
15
Electrolyte capacitors containing substances of concern —
greater than 25 mm diameter or height or similar volume
16
Lead
17
Cadmium
18
Fluids
19
Hexavalent Chromium
WEEE Selective Treatment – Enterprise D Library
2 of 6
User Interface
4, 6 and 16
Larger versions include
“wings” (media
modules that are added
to a base library).
WEEE Selective Treatment – Enterprise D Library
3 of 6
Front Aspect
Cables and PCA Board
4, 6 and 16
Cables and PCA Board
3, 4, 6 and 16
Standard Power Supply
4, 6, 15 and 16
Drives in Shuttles
4, 6 and 16
SCSI boards and cables
4, 6 and 16
Optional Power Supply
4, 6, 15 and 16
Cables and PCA Board
4, 6 and 16
Drives are found here
Drives (see above)
DVD
4, 6 and 16
WEEE Selective Treatment – Enterprise D Library
4 of 6
Rear Aspect
Pivot Motor
6 and 16
Media Slots
6
Picker, Cables and PCA Board
4, 6 and 16
Cables
6
WEEE Selective Treatment – Enterprise D Library
5 of 6
Wing
Media Slots
6
WEEE Selective Treatment – Enterprise D Library