Kirby KRC Remote Condensers
Transcription
Kirby KRC Remote Condensers
Kirby KRC Remote Condensers Field proven quality performance and endurance – HFC/HFO – Dry cooler options available Nominal capacity 8kW172kW Exclusively distributed by KRC Remote Condensors Introduction & Overview The Kirby® KRC Remote Condenser range includes the latest refrigeration technologies for upgraded performance such as 9000 series fin coils and pre coated fin for optimal corrosion protection. The units can be installed vertically or horizontally for maximum flexibility. Standard inclusions include powder coated panels and quality external rotor motor fans for long life and serviceability. For variable capacity and noise sensitive applications, Kirby offer "easy to adapt" solutions. Market Segments • Retail • Convenience • Cold Storage • Hospitality • Primary Producers • Industrial • HVAC Features & Benefits Optional Enhancements The Kirby® KRC Remote Condenser offers: Kirby® KRC Remote Condensers can be configured with the following options: • ptimised air flow and coil design for enhanced heat O transfer performance and high pressure applications • 240V - 1 Phase fan motor assemblies • irby Blue Koted aluminium fins for optimal UV and K corrosion resistance • eader clearance holes to ensure the end/divider plates H remain a leak free zone and positive air seal between all fans • • EC fan with Orbus™ fan speed control • Phase fan assemblies 3 500mm and 630mm dia • Fan motors pre-wired to terminal junction box • pecial Applications on request S Sub Cooling Circuit, Multiple Circuits, Dry Cooler, Oil Cooler, Fluid Cooler. supporting spare parts range accessible 24/7 through A the Heatcraft wholesale network. KEY CHART Extended life Sustainable solution Installation cost/time saving Improved performance Improved efficiency Flexible application Nomenclature Special (Non-regular) Options & Combinations K: Kirby Remote Condenser KRC XXX R404A Basic Capacity Watts per Degree TD/10 2 - 4P H Fan Type -4P = 4 Pole AC Fan -6P = 6 Pole AC Fan -EC = EC Fan S High Pressure Capable (R410A) Coil AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz KRC Performance Data TOTAL HEAT REJECTION AT 32˚C AMB, 0˚C SUBCOOLING MAXIMUM OPERATING PRESSURE WITH R410A = 3650kPag SOUND LEVEL DATA** R404A CAPACITY @ KTD PRODUCT NUMBER BASIC CAPACITY W/K* MIN R404A R134a R410A 3 10 15 MAX SOUND POWER SOUND PRESSURE @ 3m 20 dBA dBA 77 59.5 75.8 58.3 72.7 55.2 78.8 61.3 75.7 58.2 SINGLE COIL MODELS 350mm DIA 1PH 4P FAN – 1380RPM ONLY KRC80-4PH 803 746 819 2410 8030 12040 16050 KRC107-4PH 1076 1001 1097 3230 10760 16140 21520 KRC134-4PH 1338 1245 1365 4020 13380 20080 26770 20490 27320 500mm DIA 1PH 6P FAN – 935RPM KRC137-6PH 1366 1271 1394 4100 13660 80% Fan speed. Multiply hi speed rating by 0.85 KRC181-6PH 1807 1681 1843 5420 18070 27110 36140 KRC254-6PH 2544 2366 2595 7630 25440 38160 50880 80% Fan speed. Multiply hi speed rating by 0.85 500mm DIA 1PH 4P FAN – 1340RPM KRC164-4PH 1635 1520 1667 4900 16350 24520 32690 80% Fan speed. Multiply hi speed rating by 0.91 KRC213-4PH 2135 1986 2178 6410 21350 32030 42710 KRC317-4PH 3171 2949 3234 9510 31710 47570 63420 80% Fan speed. Multiply hi speed rating by 0.91 81 63.5 73.4 55.9 84 66.5 76.4 58.9 78.8 61.3 72.9 55.4 80.6 63.1 74.7 57.2 81.8 64.3 75.9 58.4 81.8 64.3 75.9 58.4 83.6 66.1 77.7 60.2 84.8 67.3 78.9 61.4 630mm DIA 6P "HYBLADE" FAN – 860RPM KRC389-6PH 3885 3613 3963 11660 KRC457-6PH 4572 4252 4663 13710 KRC574-6PH 5738 5337 5853 17220 KRC693-6PH 6927 6442 7065 20780 KRC861-6PH 8611 8008 8783 25830 38850 58280 77700 45720 68570 91430 57380 86080 114770 69270 103900 138530 86110 129160 172210 80% Fan speed. Multiply hi speed ratings by 0.86 80% Fan speed. Multiply hi speed ratings by 0.86 80% Fan speed. Multiply hi speed ratings by 0.86 TWIN COIL MODELS 630mm DIA 1PH 6P "HYBLADE" FAN – 860RPM KRC776-6PH 7770 7226 7926 23320 77700 116560 155400 80% Fan speed. Multiply hi speed ratings by 0.86 KRC914-6PH 9143 8503 9326 27420 91440 137140 182860 KRC1148-6PH 11477 10674 11707 34440 114760 172160 229540 80% Fan speed. Multiply hi speed ratings by 0.86 KRC1386-6PH 13853 12883 14130 41560 138540 207800 277060 KRC1722-6PH 17221 16016 17566 51660 172220 258320 344420 80% Fan speed. Multiply hi speed ratings by 0.86 * Basic Capacity - Given in Watts per degree TD based on 18KTD for ease of selection. Minimum actual KTD is 3˚. ** = Sound Power LwA re 1 picowatt. Sound pressure LpA re 20uPa. Refer to frequency spectrum data. 80% fan speed is approximately equivalent 3PH low speed. AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz 3 KRC Remote Condensors KRC Technical Specification Data COIL CONFIGURATION PRODUCT NUMBER FPI TH X ROWS MOTOR DATA CKTS VOLTS/Ph/HZ UNIT DATA AMPS/PH/MOTOR TOTAL WATTS TOTAL RLA AMPS/Ph (100%-SPD) (100%-SPD) (100%-SPD) SINGLE COIL 350mm 4 POLE 1 PH FAN KRC80-4PH 10 16 X 3 3 240/1/50 0.6 260 1.2 KRC107-4PH 10 20 X 4 4 240/1/50 0.6 260 1.2 KRC134-4PH 10 24 X 6 6 240/1/50 0.6 260 1.2 KRC137-6PH 10 24 X 6 KRC181-6PH 10 KRC254-6PH 10 KRC164-4PH 10 24 X 6 KRC213-4PH 10 KRC317-4PH 10 500mm 6 POLE 1PH FAN 6 240/1/50 1.8 360 1.8 30 X 3 5 240/1/50 1.8 720 3.6 34 X 6 10 240/1/50 1.8 720 3.6 500mm 4 POLE 1PH FAN 6 240/1/50 2.8 640 2.8 30 X 3 5 240/1/50 2.8 1280 5.6 34 X 6 10 240/1/50 2.8 1280 5.6 630mm 6 POLE 1PH HYBLADE FAN KRC389-6PH 10 36 X 5 15 240/1/50 2.65 1220 5.4 KRC457-6PH 10 36 X 3 13 240/1/50 2.65 1830 8.1 KRC574-6PH 10 36 X 5 18 240/1/50 2.65 1830 8.1 KRC693-6PH 10 32 X 3 16 240/1/50 2.65 2440 10.8 KRC861-6PH 10 32 X 5 26 240/1/50 2.65 2440 10.8 TWIN COIL 630mm 6 POLE 1PH "HYBLADE" FAN KRC778-6PH 10 2 X 36 X 5 2 X 15 240/1 2.65 2440 10.8 KRC914-6PH 10 2 X 36 X 3 2 X 18 240/1 2.65 3660 16.2 KRC1148-6PH 10 2 X 36 X 5 2 X 18 240/1 2.65 3660 16.2 KRC1386-6PH 10 2 X 32 X 3 2 X 16 240/1 2.65 4880 21.6 KRC1722-6PH 10 2 X 32 X 5 2 X 26 240/1 2.65 4880 21.6 Th x rows = tubes high x rows deep 4 AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz KRC Technical Specification Data FAN DATA PRODUCT NUMBER DIA/QTY COIL DATA AIRFLOW CHARGE (100% SPD) (80% SPD)** R410A KG* APPROX. WEIGHT KG CONN'S ODS (mm) R404A KG* GAS UNPACKED SHIP'G PACKED VOL LIQUID M3 SINGLE COIL MODEL DATA KRC80-4PH 350/2 1260 -- 1.9 1.8 15.9 12.7 29 34 0.247 KRC107-4PH 350/2 1295 -- 3.1 3.0 15.9 12.7 34 39 0.299 KRC134-4PH 350/2 1210 -- 5.6 5.4 19 15.9 46 51 0.351 KRC137-6PH 500/1 1095 955 5.6 5.4 19 15.9 51 56 0.373 KRC181-6PH 500/2 2435 2120 4.6 4.5 22.2 19 68 85 0.692 KRC254-6PH 500/2 2170 1890 10.5 10.2 25.4 22.2 93 110 KRC164-4PH 500/1 1530 1330 5.6 5.4 19 15.9 51 56 0.373 KRC213-4PH 500/2 3290 2860 4.6 4.5 22.2 19 68 85 0.692 KRC317-4PH 500/2 2910 2530 10.5 10.2 25.4 22.2 93 110 KRC389-6PH 630/2 3745 3070 11.8 11.4 31.8 28.6 129 153 1.014 KRC457-6PH 630/3 6475 5310 10.7 10.4 34.9 31.8 158 248 2.550 KRC574-6PH 630/3 5620 4610 17.9 17.3 34.9 31.8 186 276 KRC693-6PH 630/4 8755 7090 19.7 19.1 38.1 38.1 208 328 KRC861-6PH 630/4 7755 6280 32.7 31.8 38.1 38.1 263 383 4.340 TWIN COIL MODEL DATA KRC778-6PH 630/4 7490 6140 23.5 22.8 2 X 31.8 2 X 28.6 271 311 5.226 KRC914-6PH 630/6 12950 10620 21.4 20.8 2 X 34.9 2 X 31.8 309 369 6.719 KRC1148- PH 630/6 11240 9220 35.7 34.7 2 X 34.9 2 X 31.8 365 425 KRC1386-6PH 630/8 17510 14180 39.4 38.3 2 X 38.1 2 X 38.1 501 581 KRC1722-6PH 630/8 15510 12560 65.5 63.6 2 X 38.1 2 X 38.1 612 692 10.595 * = Charge at 80% liquid, 20% vapour, 55°C SCT. For pump down capacity only. PUMPDOWN CHARGE CONVERSION FACTORS TO R404A REFRIG. R404A R507 R410A R134a R407C FACTOR 1.00 1.05 1.03 1.24 1.13 REFRIG. R404A R507 R410A R134a R407C FACTOR 0.34 0.35 0.35 0.21 0.26 RATIO OF OPERATING CHARGE @ -5°C SST & 40°C SCT TO PUMPDOWN CHARGE AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz 5 KRC Remote Condensors KRC Selection Factors DISCHARGE TEMPERATURE CORRECTION FACTORS - CAPACITY RATIO TO 100°C REFRIG R404A R134a R410A R22 85°C DISCH 0.978 0.97 0.985 0.988 Factors at 32°c amb, 50°c sct. Factor will not vary significantly within the allowable KTD range Multiply the rated THR by the factor to get THR at reduced discharge gas temp. AMBIENT CORRECTION FACTORS (K1) ALTITUDE CORRECTION FACTOR (K2) AMB. °C 15 20 25 30 35 40 45 FACTOR 0.979 0.986 0.992 0.998 1.003 1.008 1.013 Divide the calculated THR at required ambient by the appropriate factor to find the required THR at the rating condition (32°C). ALT. M 0 600 800 1000 1200 1400 1600 FACTOR 1 1.04 1.06 1.075 1.09 1.11 1.12 Multiply the calculated THR at altitude by the appropriate factor to find the required THR at the rating condition (sea level). INTEGRAL SUBCOOLING* CORRECTION FACTORS (K3) S/C SEPARATE SUB-COOLING CORRECTION FACTORS KTD K 3 5 10 15 20 2 0.966 0.976 0.989 0.994 0.996 0.934 0.975 0.986 0.990 6 0.946 0.972 0.980 8 0.898 0.960 0.966 4 Multiply the rated THR at zero subcooling by the factor at the required KTD and degree of subcooling to give the new THR including subcooling. SUBCOOLING 4K 6K 8K 10K FACTOR 0.95 0.93 0.91 0.88 Multiply the rated THR by the factor at the required subcooling (K) to find the THR of the condensing only section. Use the condensing only THR as basis of selection. Condensing only THR implies zero subcooling as per usual rating condition. * Integral sub-cooling is defined as achieving the required degree of subcooling without using a separate subcooling section in the coil. In this case the subcooled liquid exits the condenser to the receiver. The standard coil circuiting is retained. For separate sub-cooling, there is a section of the coil used separately to sub-cool liquid coming from the receiver. This is available as an extra cost special circuiting option. The percentage of coil area required depends on the degree of subcooling relative to design KTD. Sound Data FANS NUMBER LINEAR SOUND POWER DB @ CENTRE FREQUENCY HZ 63 125 250 500 1000 2000 4000 8000 67.6 61.1 51.3 350mm 1PH 4 POLE FANS 100% FAN SPEED 2 81.9 77.6 75.3 75.3 72.5 1 83.5 81.6 77.8 73.2 69.4 65.9 60.3 54.7 2 86.5 84.6 80.8 76.2 72.4 68.9 63.3 57.7 500mm 1PH 6 POLE FANS 100% SPEED 500mm 1PH 6 POLE FANS 80% FAN SPEED 1 78.4 77.1 74.1 70.6 67.0 63.0 57.1 48.0 2 81.4 80.1 77.1 73.6 70 66 60.1 51 500mm 1PH 4 POLE FANS 100% SPEED 1 90.9 83.2 80.0 77.9 76.9 72.0 64.1 53.4 2 94.0 86.2 83.0 80.9 79.9 75.0 67.1 56.4 500mm 1PH 4 POLE FANS 80% FAN SPEED 1 84.4 75.8 2 87.4 78.8 74.4 70.8 68.1 62.5 54.5 45.3 77.5 73.8 71.1 65.5 57.5 48.3 66.6 57.4 51.1 52.9 630mm 1PH 6 POLE "HYBLADE" FANS 100% FAN SPEED 2 98.8 89.2 76.6 72.4 72.0 3 100.5 91.0 78.4 74.2 73.8 68.4 59.1 4 101.8 92.2 79.6 75.4 75.0 69.6 60.4 54.1 6 103.6 94.0 81.4 77.2 76.8 71.4 62.1 55.9 8 104.8 95.2 82.6 78.4 78.0 72.7 63.4 57.1 2 92.8 79.4 71.1 69.0 67.5 60.5 51.8 46.4 3 94.6 81.1 72.8 70.7 69.3 62.2 53.6 48.1 4 95.8 82.4 74.1 72.0 70.5 63.5 54.8 49.4 630mm 1PH 6 POLE "HYBLADE" FANS 80% FAN SPEED 6 6 97.6 84.2 75.8 73.8 72.3 65.2 56.6 51.1 8 98.8 85.4 77.1 75.0 73.5 66.5 57.8 52.4 AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz KRC Dimensional Data PRODUCT NUMBER FAN Ø X QTY. KRC80-4PH DIMENSIONAL DATA (mm) A B C D E F G Ø350 X 2 452 48 80 470 500 443 580 KRC107-4PH Ø350 X 2 452 48 80 570 500 520 KRC134-4PH Ø350 X 2 452 48 80 670 500 647 KRC137-6PH Ø500 X 1 452 48 80 670 500 KRC164-4PH Ø500 X 1 452 48 80 670 500 KRC181-6PH Ø500 X 2 766 54 75 849 KRC213-4PH Ø500 X 2 766 54 75 849 KRC254-6PH Ø500 X 2 766 54 75 KRC317-4PH Ø500 X 2 766 54 KRC389-6PH Ø630 X 2 766 54 KRC457-6PH Ø630 X 3 766 KRC574-6PH Ø630 X 3 766 KRC693-6PH Ø630 X 4 KRC861-6PH Ø630 X 4 H DIAG. WEIGHT KG J K L M N P W 705 40 165 951 877 25 390 927 29 580 705 40 165 951 877 25 390 927 34 580 725 40 165 951 877 25 390 927 46 647 580 745 40 165 951 877 25 390 927 51 647 580 745 40 165 951 877 25 390 927 68 500 788 895 1020 62 220 1262 1165 38 605 1241 93 500 788 895 1020 62 220 1262 1165 38 605 1241 51 954 500 915 895 1020 62 255 1262 1165 38 605 1241 68 75 954 500 915 895 1020 62 255 1262 1165 38 605 1241 75 954 500 965 895 1050 62 220 1675 1505 38 605 1581 54 75 954 750 965 895 1050 62 255 2408 2240 38 605 2316 54 75 954 750 965 895 1050 62 255 2408 2240 38 605 2316 186 766 54 75 954 750 1065 1000 1050 18 440 3205 3003 44 610 3091 208 840 80 80 1107 750 1065 1000 1050 18 440 3205 3003 44 610 3091 263 DIAGRAM A SINGLE CIRCUIT 93 129 158 Single Coil – KRC80 TO KRC861 Diagram A "E" MIN. ALL ROUND Horizontal Air Flow K AIR FLOW F OUTLET LIQUID B A L C G Vertical Air Flow "E" MIN. ALL ROUND AIR FLOW H OUTLET LIQUID P J D M N W AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz 7 KRC Remote Condensors KRC Dimensional Data PRODUCT NUMBER FAN Ø X QTY. DIMENSIONAL DATA (mm) A B C D E F G H J K L M N P W DIAG. WEIGHT KG TWIN CIRCUIT KRC778-6PH Ø630 X 4 KRC914-6PH Ø630 X 6 KRC1148-6PH Ø630 X 6 DIAGRAM B 1929 1200 1933 - 1145 18 - 695 1505 44 695 1581 271 1929 1200 1933 - 1145 18 - 695 2240 44 695 2316 DIAG B 309 1929 1200 1933 - 1145 18 - 695 2240 44 695 2316 365 Twin Coil – KRC718 TO KRC1148 Diagram B Horizontal Air Flow 1200 MIN. 365 AIR FLOW INLET GAS 2133 AIR FLOW OUTLET LIQUID 80 TYP. 3205 840 1000 Vertical Air Flow "E" MIN. ALL ROUND AIR FLOW INLET GAS H OUTLET LIQUID P J D 8 M N W AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz KRC Dimensional Data DIMENSIONAL DATA (mm) PRODUCT NUMBER FAN Ø X QTY. KRC1386-6PH Ø630 X 8 KRC1722-6PH Ø630 X 8 A B C D E F G H J K L M N P W DIAG. WEIGHT KG TWIN CIRCUIT 501 REFER DIAGRAM C FOR DIMENSIONS 612 Twin Coil – KRC1386 TO KRC1722 Diagram C Horizontal Air Flow 1200 MIN. MIN. 1200 365 AIR FLOW 2133 INLET GAS 21 AIR FLOW OUTLET LIQUID 80 TYP. 3205 840 1000 Vertical Air Flow INLET GAS 1200 MIN. ALL ROUND AIR FLOW 1145 OUTLET LIQUID 610 2100 18 TYP. 2135 AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz 1476 1527 44 3091 9 KRC Remote Condensors Compressor Factor Performance Data Open Drive Compressors TOTAL HEAT REJECTION FACTORS - OPEN DRIVE COMPRESSORS SCT -45 -40 -35 -30 -25 1.45 1.4 1.35 1.31 40 1.5 1.44 1.39 45 1.55 1.49 1.43 50 1.61 1.54 55 1.68 1.61 -20 -15 -10 -5 0 5 10 HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R22 35 1.26 1.23 1.2 1.17 1.14 1.11 1.09 1.35 1.3 1.26 1.22 1.19 1.16 1.13 1.11 1.39 1.34 1.29 1.26 1.22 1.19 1.16 1.13 1.48 1.43 1.38 1.33 1.29 1.26 1.22 1.19 1.15 1.54 1.49 1.43 1.38 1.34 1.3 1.26 1.22 1.19 HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R134a 35 1.39 1.35 1.3 1.25 1.22 1.19 1.16 1.13 1.11 1.09 40 1.46 1.41 1.35 1.3 1.27 1.22 1.19 1.16 1.14 1.11 45 1.52 1.46 1.41 1.35 1.31 1.27 1.23 1.19 1.17 1.14 50 1.59 1.52 1.46 1.41 1.36 1.31 1.28 1.23 1.2 1.17 55 1.65 1.57 1.52 1.46 1.41 1.35 1.31 1.28 1.24 1.23 HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R404A 35 1.47 1.44 1.41 1.37 1.33 1.29 1.25 1.21 1.18 1.14 1.11 40 1.54 1.51 1.47 1.43 1.38 1.34 1.29 1.25 1.21 1.18 1.14 45 1.63 1.60 1.55 1.50 1.45 1.40 1.35 1.30 1.26 1.22 1.18 50 1.76 1.71 1.66 1.60 1.54 1.48 1.42 1.36 1.31 1.27 1.22 55 1.93 1.88 1.81 1.73 1.66 1.58 1.51 1.45 1.38 1.33 1.28 HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R407B 35 1.61 1.53 1.47 1.41 1.35 1.31 1.27 1.22 1.19 1.16 1.13 1.1 40 1.68 1.62 1.56 1.49 1.39 1.36 1.32 1.27 1.23 1.2 1.15 1.13 45 1.79 1.72 1.64 1.56 1.49 1.43 1.39 1.33 1.28 1.23 1.2 1.16 50 1.93 1.82 1.75 1.67 1.57 1.51 1.44 1.39 1.34 1.3 1.23 1.21 55 2.05 1.96 1.89 1.77 1.67 1.6 1.53 1.46 1.41 1.35 1.3 1.26 35 1.48 1.42 1.37 1.32 1.27 1.24 1.2 1.17 1.14 1.11 1.09 40 1.53 1.47 1.41 1.37 1.32 1.27 1.23 1.2 1.17 1.13 1.11 45 1.58 1.52 1.46 1.41 1.36 1.31 1.28 1.23 1.2 1.17 1.14 50 1.67 1.59 1.51 1.46 1.41 1.35 1.31 1.28 1.24 1.2 1.16 55 1.74 1.67 1.59 1.52 1.46 1.41 1.37 1.32 1.28 1.24 1.2 HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R407C 10 AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz Compressor Factor Performance Data Hermetic Reciprocating Compressors TOTAL HEAT REJECTION FACTORS - HERMETIC RECIPROCATING COMPRESSORS SCT -45 -40 -35 -30 -25 -20 -15 -10 -5 0 5 10 1.18 HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R22 35 1.68 1.61 1.55 1.49 1.43 1.38 1.34 1.3 1.25 1.21 40 1.73 1.65 1.59 1.53 1.47 1.41 1.36 1.32 1.27 1.23 1.2 45 1.78 1.7 1.63 1.57 1.51 1.44 1.4 1.35 1.3 1.26 1.22 50 1.84 1.75 1.68 1.61 1.55 1.48 1.43 1.39 1.33 1.29 1.25 55 1.91 1.82 1.74 1.67 1.6 1.53 1.48 1.43 1.37 1.32 1.28 HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R134a 35 1.6 1.55 1.48 1.42 1.37 1.33 1.29 1.24 1.21 1.18 40 1.67 1.61 1.53 1.47 1.42 1.36 1.32 1.27 1.24 1.2 45 1.73 1.66 1.59 1.52 1.46 1.41 1.36 1.3 1.27 1.23 50 1.8 1.72 1.64 1.58 1.51 1.45 1.41 1.34 1.3 1.26 1.86 1.77 1.7 1.63 1.56 1.49 1.44 1.39 1.343 1.29 55 HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R404A 35 1.70 1.66 1.61 1.55 1.50 1.44 1.39 1.34 1.29 1.25 1.21 40 1.78 1.73 1.68 1.62 1.56 1.50 1.44 1.39 1.33 1.28 1.24 45 1.87 1.82 1.76 1.69 1.63 1.56 1.50 1.44 1.37 1.32 1.27 50 2.00 1.95 1.88 1.80 1.72 1.64 1.57 1.50 1.43 1.37 1.33 55 2.20 2.11 2.05 1.94 1.85 1.75 1.67 1.59 1.50 1.44 1.37 HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R407B 35 1.87 1.76 1.68 1.61 1.53 1.48 1.42 1.36 1.32 1.27 1.23 1.19 40 1.95 1.85 45 2.06 1.96 1.78 1.7 1.57 1.53 1.47 1.41 1.36 1.31 1.25 1.23 1.86 1.76 1.68 1.61 1.55 1.47 1.41 1.34 1.3 1.25 50 2.2 55 2.33 2.07 1.97 1.88 1.76 1.68 1.6 1.53 1.47 1.41 1.35 1.31 2.21 2.11 1.98 1.87 1.77 1.69 1.6 1.55 1.46 1.4 1.35 1.18 HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R407C 35 1.71 1.63 1.57 1.5 1.44 1.39 1.34 1.3 1.25 1.21 40 1.76 1.68 1.61 1.55 1.49 1.42 1.37 1.33 1.28 1.23 1.2 45 1.81 1.73 1.66 1.59 1.53 1.46 1.42 1.36 1.31 1.27 1.23 50 1.9 1.81 1.71 1.64 1.58 1.5 1.45 1.41 1.35 1.3 1.26 55 1.98 1.88 1.8 1.7 1.63 1.56 1.51 1.45 1.39 1.34 1.29 Supporting Documentation • CL264.doc – KRC Air Cooled Condenser Handbook Product Specification • Supported through and heatload information with product selection • Complementary Kirby Project Tool assists with project estimations AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz 11 13 23 50 0800 653 330 heatcraft.com.au heatcraft.co.nz ® and ™ Registered Trade Mark and Trade Mark of Heatcraft Australia Pty Ltd © Copyright 2016 Heatcraft Australia Pty Ltd KIRBYKRCCOND_0816 The contents of this brochure are copyright protected and may not be reproduced in any form without the written consent of Heatcraft. Recommendations and advice regarding the use of the products described in this publication are to be taken as a guide only and are given without liability on the part of the company or its employees. As Heatcraft continually improves its product range and processes, Heatcraft reserves the right to change product specifications without any prior notification. Please refer to the Heatcraft website for the latest version of this publication. The purchaser should independently determine the suitability of the product for the intended use and application and that the product complies with relevant standards. Heatcraft accepts no responsibility for loss or damage (direct or indirect and including consequential loss, loss of profits or opportunity and economic loss) however arising which results from any errors or omissions in the information contained in this publication or arising from the use or application of the information contained herein.
Similar documents
2012 Parts Manual.book
DESCRIPTION Switch Float Rule-A-Matic Pump Bilge 1100 GPH Outlet Flange 12MP.OEM Outlet 12V Horn “H” Phase II 12V Horn Grill Off-white Screw-in Compass Ritchie Flush Mt-Dir Read
More information2011 Parts Manual - Grady
Thru Hull 1” w/ Reg Thread Thru Hull 1 1/8” w/ Reg Thread Rings Scupper Outer (White) Flap Rubber Scupper Washer Spacing 1 3/8”
More information