Kirby KRC Remote Condensers

Transcription

Kirby KRC Remote Condensers
Kirby KRC
Remote
Condensers
Field proven quality
performance and endurance
– HFC/HFO
– Dry cooler options available
Nominal capacity
8kW172kW
Exclusively distributed by
KRC Remote
Condensors
Introduction & Overview
The Kirby® KRC Remote Condenser range includes the latest refrigeration technologies for upgraded performance such as 9000 series
fin coils and pre coated fin for optimal corrosion protection. The units can be installed vertically or horizontally for maximum flexibility.
Standard inclusions include powder coated panels and quality external rotor motor fans for long life and serviceability. For variable
capacity and noise sensitive applications, Kirby offer "easy to adapt" solutions.
Market Segments
•
Retail
•
Convenience
•
Cold Storage
•
Hospitality
•
Primary Producers
•
Industrial
•
HVAC
Features & Benefits
Optional Enhancements
The Kirby® KRC Remote Condenser offers:
Kirby® KRC Remote Condensers can be configured
with the following options:
•
ptimised air flow and coil design for enhanced heat
O
transfer performance and high pressure applications
•
240V - 1 Phase fan motor assemblies
•
irby Blue Koted aluminium fins for optimal UV and
K
corrosion resistance
•
eader clearance holes to ensure the end/divider plates
H
remain a leak free zone and positive air seal between
all fans
•
•
EC fan with Orbus™ fan
speed control
•
Phase fan assemblies 3
500mm and 630mm dia
•
Fan motors pre-wired to terminal junction box
•
pecial Applications on request S
Sub Cooling Circuit, Multiple Circuits,
Dry Cooler, Oil Cooler, Fluid Cooler.
supporting spare parts range accessible 24/7 through
A
the Heatcraft wholesale network.
KEY CHART
Extended life
Sustainable solution
Installation cost/time saving
Improved performance
Improved efficiency
Flexible application
Nomenclature
Special (Non-regular)
Options &
Combinations
K: Kirby Remote
Condenser
KRC
XXX
R404A Basic Capacity
Watts per Degree TD/10
2
- 4P
H
Fan Type
-4P = 4 Pole AC Fan
-6P = 6 Pole AC Fan
-EC = EC Fan
S
High Pressure Capable
(R410A) Coil
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
KRC Performance Data
TOTAL HEAT REJECTION AT 32˚C AMB, 0˚C SUBCOOLING
MAXIMUM OPERATING PRESSURE WITH R410A = 3650kPag
SOUND LEVEL DATA**
R404A CAPACITY @ KTD
PRODUCT
NUMBER
BASIC CAPACITY W/K*
MIN
R404A
R134a
R410A
3
10
15
MAX
SOUND
POWER
SOUND
PRESSURE @ 3m
20
dBA
dBA
77
59.5
75.8
58.3
72.7
55.2
78.8
61.3
75.7
58.2
SINGLE COIL MODELS 350mm DIA 1PH 4P FAN – 1380RPM ONLY
KRC80-4PH
803
746
819
2410
8030
12040
16050
KRC107-4PH
1076
1001
1097
3230
10760
16140
21520
KRC134-4PH
1338
1245
1365
4020
13380
20080
26770
20490
27320
500mm DIA 1PH 6P FAN – 935RPM
KRC137-6PH
1366
1271
1394
4100
13660
80% Fan speed. Multiply hi speed rating by 0.85
KRC181-6PH
1807
1681
1843
5420
18070
27110
36140
KRC254-6PH
2544
2366
2595
7630
25440
38160
50880
80% Fan speed. Multiply hi speed rating by 0.85
500mm DIA 1PH 4P FAN – 1340RPM
KRC164-4PH
1635
1520
1667
4900
16350
24520
32690
80% Fan speed. Multiply hi speed rating by 0.91
KRC213-4PH
2135
1986
2178
6410
21350
32030
42710
KRC317-4PH
3171
2949
3234
9510
31710
47570
63420
80% Fan speed. Multiply hi speed rating by 0.91
81
63.5
73.4
55.9
84
66.5
76.4
58.9
78.8
61.3
72.9
55.4
80.6
63.1
74.7
57.2
81.8
64.3
75.9
58.4
81.8
64.3
75.9
58.4
83.6
66.1
77.7
60.2
84.8
67.3
78.9
61.4
630mm DIA 6P "HYBLADE" FAN – 860RPM
KRC389-6PH
3885
3613
3963
11660
KRC457-6PH
4572
4252
4663
13710
KRC574-6PH
5738
5337
5853
17220
KRC693-6PH
6927
6442
7065
20780
KRC861-6PH
8611
8008
8783
25830
38850
58280
77700
45720
68570
91430
57380
86080
114770
69270
103900
138530
86110
129160
172210
80% Fan speed. Multiply hi speed ratings by 0.86
80% Fan speed. Multiply hi speed ratings by 0.86
80% Fan speed. Multiply hi speed ratings by 0.86
TWIN COIL MODELS 630mm DIA 1PH 6P "HYBLADE" FAN – 860RPM
KRC776-6PH
7770
7226
7926
23320
77700
116560
155400
80% Fan speed. Multiply hi speed ratings by 0.86
KRC914-6PH
9143
8503
9326
27420
91440
137140
182860
KRC1148-6PH
11477
10674
11707
34440
114760
172160
229540
80% Fan speed. Multiply hi speed ratings by 0.86
KRC1386-6PH
13853
12883
14130
41560
138540
207800
277060
KRC1722-6PH
17221
16016
17566
51660
172220
258320
344420
80% Fan speed. Multiply hi speed ratings by 0.86
* Basic Capacity - Given in Watts per degree TD based on 18KTD for ease of selection. Minimum actual KTD is 3˚.
** = Sound Power LwA re 1 picowatt. Sound pressure LpA re 20uPa. Refer to frequency spectrum data.
80% fan speed is approximately equivalent 3PH low speed.
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
3
KRC Remote
Condensors
KRC Technical Specification Data
COIL CONFIGURATION
PRODUCT
NUMBER
FPI
TH X ROWS
MOTOR DATA
CKTS
VOLTS/Ph/HZ
UNIT DATA
AMPS/PH/MOTOR
TOTAL WATTS
TOTAL
RLA AMPS/Ph
(100%-SPD)
(100%-SPD)
(100%-SPD)
SINGLE COIL
350mm 4 POLE 1 PH FAN
KRC80-4PH
10
16 X 3
3
240/1/50
0.6
260
1.2
KRC107-4PH
10
20 X 4
4
240/1/50
0.6
260
1.2
KRC134-4PH
10
24 X 6
6
240/1/50
0.6
260
1.2
KRC137-6PH
10
24 X 6
KRC181-6PH
10
KRC254-6PH
10
KRC164-4PH
10
24 X 6
KRC213-4PH
10
KRC317-4PH
10
500mm 6 POLE 1PH FAN
6
240/1/50
1.8
360
1.8
30 X 3
5
240/1/50
1.8
720
3.6
34 X 6
10
240/1/50
1.8
720
3.6
500mm 4 POLE 1PH FAN
6
240/1/50
2.8
640
2.8
30 X 3
5
240/1/50
2.8
1280
5.6
34 X 6
10
240/1/50
2.8
1280
5.6
630mm 6 POLE 1PH HYBLADE FAN
KRC389-6PH
10
36 X 5
15
240/1/50
2.65
1220
5.4
KRC457-6PH
10
36 X 3
13
240/1/50
2.65
1830
8.1
KRC574-6PH
10
36 X 5
18
240/1/50
2.65
1830
8.1
KRC693-6PH
10
32 X 3
16
240/1/50
2.65
2440
10.8
KRC861-6PH
10
32 X 5
26
240/1/50
2.65
2440
10.8
TWIN COIL
630mm 6 POLE 1PH "HYBLADE" FAN
KRC778-6PH
10
2 X 36 X 5
2 X 15
240/1
2.65
2440
10.8
KRC914-6PH
10
2 X 36 X 3
2 X 18
240/1
2.65
3660
16.2
KRC1148-6PH
10
2 X 36 X 5
2 X 18
240/1
2.65
3660
16.2
KRC1386-6PH
10
2 X 32 X 3
2 X 16
240/1
2.65
4880
21.6
KRC1722-6PH
10
2 X 32 X 5
2 X 26
240/1
2.65
4880
21.6
Th x rows = tubes high x rows deep
4
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
KRC Technical Specification Data
FAN DATA
PRODUCT
NUMBER
DIA/QTY
COIL DATA
AIRFLOW
CHARGE
(100% SPD)
(80% SPD)**
R410A KG*
APPROX. WEIGHT KG
CONN'S ODS (mm)
R404A KG*
GAS
UNPACKED
SHIP'G
PACKED
VOL
LIQUID
M3
SINGLE COIL MODEL DATA
KRC80-4PH
350/2
1260
--
1.9
1.8
15.9
12.7
29
34
0.247
KRC107-4PH
350/2
1295
--
3.1
3.0
15.9
12.7
34
39
0.299
KRC134-4PH
350/2
1210
--
5.6
5.4
19
15.9
46
51
0.351
KRC137-6PH
500/1
1095
955
5.6
5.4
19
15.9
51
56
0.373
KRC181-6PH
500/2
2435
2120
4.6
4.5
22.2
19
68
85
0.692
KRC254-6PH
500/2
2170
1890
10.5
10.2
25.4
22.2
93
110
KRC164-4PH
500/1
1530
1330
5.6
5.4
19
15.9
51
56
0.373
KRC213-4PH
500/2
3290
2860
4.6
4.5
22.2
19
68
85
0.692
KRC317-4PH
500/2
2910
2530
10.5
10.2
25.4
22.2
93
110
KRC389-6PH
630/2
3745
3070
11.8
11.4
31.8
28.6
129
153
1.014
KRC457-6PH
630/3
6475
5310
10.7
10.4
34.9
31.8
158
248
2.550
KRC574-6PH
630/3
5620
4610
17.9
17.3
34.9
31.8
186
276
KRC693-6PH
630/4
8755
7090
19.7
19.1
38.1
38.1
208
328
KRC861-6PH
630/4
7755
6280
32.7
31.8
38.1
38.1
263
383
4.340
TWIN COIL MODEL DATA
KRC778-6PH
630/4
7490
6140
23.5
22.8
2 X 31.8
2 X 28.6
271
311
5.226
KRC914-6PH
630/6
12950
10620
21.4
20.8
2 X 34.9
2 X 31.8
309
369
6.719
KRC1148- PH
630/6
11240
9220
35.7
34.7
2 X 34.9
2 X 31.8
365
425
KRC1386-6PH
630/8
17510
14180
39.4
38.3
2 X 38.1
2 X 38.1
501
581
KRC1722-6PH
630/8
15510
12560
65.5
63.6
2 X 38.1
2 X 38.1
612
692
10.595
* = Charge at 80% liquid, 20% vapour, 55°C SCT. For pump down capacity only.
PUMPDOWN CHARGE CONVERSION FACTORS TO R404A
REFRIG.
R404A
R507
R410A
R134a
R407C
FACTOR
1.00
1.05
1.03
1.24
1.13
REFRIG.
R404A
R507
R410A
R134a
R407C
FACTOR
0.34
0.35
0.35
0.21
0.26
RATIO OF OPERATING CHARGE @ -5°C SST & 40°C SCT TO PUMPDOWN CHARGE
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
5
KRC Remote
Condensors
KRC Selection Factors
DISCHARGE TEMPERATURE CORRECTION FACTORS - CAPACITY RATIO TO 100°C
REFRIG
R404A
R134a
R410A
R22
85°C DISCH
0.978
0.97
0.985
0.988
Factors at 32°c amb, 50°c sct. Factor will not vary significantly within the allowable KTD range Multiply the rated THR by the factor to get THR at reduced discharge gas temp.
AMBIENT CORRECTION FACTORS (K1)
ALTITUDE CORRECTION FACTOR (K2)
AMB. °C
15
20
25
30
35
40
45
FACTOR
0.979
0.986
0.992
0.998
1.003
1.008
1.013
Divide the calculated THR at required ambient by the appropriate factor to find the required THR at
the rating condition (32°C).
ALT. M
0
600
800
1000
1200
1400
1600
FACTOR
1
1.04
1.06
1.075
1.09
1.11
1.12
Multiply the calculated THR at altitude by the appropriate factor to find the required THR at the
rating condition (sea level).
INTEGRAL SUBCOOLING* CORRECTION FACTORS (K3)
S/C
SEPARATE SUB-COOLING CORRECTION FACTORS
KTD
K
3
5
10
15
20
2
0.966
0.976
0.989
0.994
0.996
0.934
0.975
0.986
0.990
6
0.946
0.972
0.980
8
0.898
0.960
0.966
4
Multiply the rated THR at zero subcooling by the factor at the required KTD and degree of
subcooling to give the new THR including subcooling.
SUBCOOLING
4K
6K
8K
10K
FACTOR
0.95
0.93
0.91
0.88
Multiply the rated THR by the factor at the required subcooling (K) to find the THR of the condensing
only section. Use the condensing only THR as basis of selection. Condensing only THR implies zero
subcooling as per usual rating condition.
* Integral sub-cooling is defined as achieving the required degree of subcooling without using a
separate subcooling section in the coil. In this case the subcooled liquid exits the condenser to
the receiver. The standard coil circuiting is retained. For separate sub-cooling, there is a section
of the coil used separately to sub-cool liquid coming from the receiver. This is available as an
extra cost special circuiting option. The percentage of coil area required depends on the degree
of subcooling relative to design KTD.
Sound Data
FANS
NUMBER
LINEAR SOUND POWER DB @ CENTRE FREQUENCY HZ
63
125
250
500
1000
2000
4000
8000
67.6
61.1
51.3
350mm 1PH 4 POLE FANS 100% FAN SPEED
2
81.9
77.6
75.3
75.3
72.5
1
83.5
81.6
77.8
73.2
69.4
65.9
60.3
54.7
2
86.5
84.6
80.8
76.2
72.4
68.9
63.3
57.7
500mm 1PH 6 POLE FANS 100% SPEED
500mm 1PH 6 POLE FANS 80% FAN SPEED
1
78.4
77.1
74.1
70.6
67.0
63.0
57.1
48.0
2
81.4
80.1
77.1
73.6
70
66
60.1
51
500mm 1PH 4 POLE FANS 100% SPEED
1
90.9
83.2
80.0
77.9
76.9
72.0
64.1
53.4
2
94.0
86.2
83.0
80.9
79.9
75.0
67.1
56.4
500mm 1PH 4 POLE FANS 80% FAN SPEED
1
84.4
75.8
2
87.4
78.8
74.4
70.8
68.1
62.5
54.5
45.3
77.5
73.8
71.1
65.5
57.5
48.3
66.6
57.4
51.1
52.9
630mm 1PH 6 POLE "HYBLADE" FANS 100% FAN SPEED
2
98.8
89.2
76.6
72.4
72.0
3
100.5
91.0
78.4
74.2
73.8
68.4
59.1
4
101.8
92.2
79.6
75.4
75.0
69.6
60.4
54.1
6
103.6
94.0
81.4
77.2
76.8
71.4
62.1
55.9
8
104.8
95.2
82.6
78.4
78.0
72.7
63.4
57.1
2
92.8
79.4
71.1
69.0
67.5
60.5
51.8
46.4
3
94.6
81.1
72.8
70.7
69.3
62.2
53.6
48.1
4
95.8
82.4
74.1
72.0
70.5
63.5
54.8
49.4
630mm 1PH 6 POLE "HYBLADE" FANS 80% FAN SPEED
6
6
97.6
84.2
75.8
73.8
72.3
65.2
56.6
51.1
8
98.8
85.4
77.1
75.0
73.5
66.5
57.8
52.4
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
KRC Dimensional Data
PRODUCT
NUMBER
FAN Ø X
QTY.
KRC80-4PH
DIMENSIONAL DATA (mm)
A
B
C
D
E
F
G
Ø350 X 2
452
48
80
470
500
443
580
KRC107-4PH
Ø350 X 2
452
48
80
570
500
520
KRC134-4PH
Ø350 X 2
452
48
80
670
500
647
KRC137-6PH
Ø500 X 1
452
48
80
670
500
KRC164-4PH
Ø500 X 1
452
48
80
670
500
KRC181-6PH
Ø500 X 2
766
54
75
849
KRC213-4PH
Ø500 X 2
766
54
75
849
KRC254-6PH
Ø500 X 2
766
54
75
KRC317-4PH
Ø500 X 2
766
54
KRC389-6PH
Ø630 X 2
766
54
KRC457-6PH
Ø630 X 3
766
KRC574-6PH
Ø630 X 3
766
KRC693-6PH
Ø630 X 4
KRC861-6PH
Ø630 X 4
H
DIAG.
WEIGHT
KG
J
K
L
M
N
P
W
705
40
165
951
877
25
390
927
29
580
705
40
165
951
877
25
390
927
34
580
725
40
165
951
877
25
390
927
46
647
580
745
40
165
951
877
25
390
927
51
647
580
745
40
165
951
877
25
390
927
68
500
788
895
1020
62
220
1262
1165
38
605
1241
93
500
788
895
1020
62
220
1262
1165
38
605
1241
51
954
500
915
895
1020
62
255
1262
1165
38
605
1241
68
75
954
500
915
895
1020
62
255
1262
1165
38
605
1241
75
954
500
965
895
1050
62
220
1675
1505
38
605
1581
54
75
954
750
965
895
1050
62
255
2408
2240
38
605
2316
54
75
954
750
965
895
1050
62
255
2408
2240
38
605
2316
186
766
54
75
954
750
1065
1000
1050
18
440
3205
3003
44
610
3091
208
840
80
80
1107
750
1065
1000
1050
18
440
3205
3003
44
610
3091
263
DIAGRAM A
SINGLE CIRCUIT
93
129
158
Single Coil – KRC80 TO KRC861
Diagram A
"E" MIN.
ALL ROUND
Horizontal Air Flow
K
AIR
FLOW
F
OUTLET
LIQUID
B
A
L
C
G
Vertical Air Flow
"E" MIN.
ALL ROUND
AIR
FLOW
H
OUTLET
LIQUID
P
J
D
M
N
W
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
7
KRC Remote
Condensors
KRC Dimensional Data
PRODUCT
NUMBER
FAN Ø X
QTY.
DIMENSIONAL DATA (mm)
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W
DIAG.
WEIGHT
KG
TWIN CIRCUIT
KRC778-6PH
Ø630 X 4
KRC914-6PH
Ø630 X 6
KRC1148-6PH
Ø630 X 6
DIAGRAM B
1929
1200
1933
-
1145
18
-
695
1505
44
695
1581
271
1929
1200
1933
-
1145
18
-
695
2240
44
695
2316 DIAG B
309
1929
1200
1933
-
1145
18
-
695
2240
44
695
2316
365
Twin Coil – KRC718 TO KRC1148
Diagram B
Horizontal Air Flow
1200 MIN.
365
AIR
FLOW
INLET
GAS
2133
AIR
FLOW
OUTLET
LIQUID
80 TYP.
3205
840
1000
Vertical Air Flow
"E" MIN.
ALL ROUND
AIR
FLOW
INLET
GAS
H
OUTLET
LIQUID
P
J
D
8
M
N
W
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
KRC Dimensional Data
DIMENSIONAL DATA (mm)
PRODUCT
NUMBER
FAN Ø X
QTY.
KRC1386-6PH
Ø630 X 8
KRC1722-6PH
Ø630 X 8
A
B
C
D
E
F
G
H
J
K
L
M
N
P
W
DIAG.
WEIGHT
KG
TWIN CIRCUIT
501
REFER DIAGRAM C FOR DIMENSIONS
612
Twin Coil – KRC1386 TO KRC1722
Diagram C
Horizontal Air Flow
1200 MIN.
MIN.
1200
365
AIR
FLOW
2133
INLET
GAS
21
AIR
FLOW
OUTLET
LIQUID
80 TYP.
3205
840
1000
Vertical Air Flow
INLET
GAS
1200 MIN.
ALL ROUND
AIR
FLOW
1145
OUTLET
LIQUID
610
2100
18 TYP.
2135
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
1476
1527
44
3091
9
KRC Remote
Condensors
Compressor Factor Performance Data
Open Drive Compressors
TOTAL HEAT REJECTION FACTORS - OPEN DRIVE COMPRESSORS
SCT
-45
-40
-35
-30
-25
1.45
1.4
1.35
1.31
40
1.5
1.44
1.39
45
1.55
1.49
1.43
50
1.61
1.54
55
1.68
1.61
-20
-15
-10
-5
0
5
10
HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R22
35
1.26
1.23
1.2
1.17
1.14
1.11
1.09
1.35
1.3
1.26
1.22
1.19
1.16
1.13
1.11
1.39
1.34
1.29
1.26
1.22
1.19
1.16
1.13
1.48
1.43
1.38
1.33
1.29
1.26
1.22
1.19
1.15
1.54
1.49
1.43
1.38
1.34
1.3
1.26
1.22
1.19
HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R134a
35
1.39
1.35
1.3
1.25
1.22
1.19
1.16
1.13
1.11
1.09
40
1.46
1.41
1.35
1.3
1.27
1.22
1.19
1.16
1.14
1.11
45
1.52
1.46
1.41
1.35
1.31
1.27
1.23
1.19
1.17
1.14
50
1.59
1.52
1.46
1.41
1.36
1.31
1.28
1.23
1.2
1.17
55
1.65
1.57
1.52
1.46
1.41
1.35
1.31
1.28
1.24
1.23
HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R404A
35
1.47
1.44
1.41
1.37
1.33
1.29
1.25
1.21
1.18
1.14
1.11
40
1.54
1.51
1.47
1.43
1.38
1.34
1.29
1.25
1.21
1.18
1.14
45
1.63
1.60
1.55
1.50
1.45
1.40
1.35
1.30
1.26
1.22
1.18
50
1.76
1.71
1.66
1.60
1.54
1.48
1.42
1.36
1.31
1.27
1.22
55
1.93
1.88
1.81
1.73
1.66
1.58
1.51
1.45
1.38
1.33
1.28
HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R407B
35
1.61
1.53
1.47
1.41
1.35
1.31
1.27
1.22
1.19
1.16
1.13
1.1
40
1.68
1.62
1.56
1.49
1.39
1.36
1.32
1.27
1.23
1.2
1.15
1.13
45
1.79
1.72
1.64
1.56
1.49
1.43
1.39
1.33
1.28
1.23
1.2
1.16
50
1.93
1.82
1.75
1.67
1.57
1.51
1.44
1.39
1.34
1.3
1.23
1.21
55
2.05
1.96
1.89
1.77
1.67
1.6
1.53
1.46
1.41
1.35
1.3
1.26
35
1.48
1.42
1.37
1.32
1.27
1.24
1.2
1.17
1.14
1.11
1.09
40
1.53
1.47
1.41
1.37
1.32
1.27
1.23
1.2
1.17
1.13
1.11
45
1.58
1.52
1.46
1.41
1.36
1.31
1.28
1.23
1.2
1.17
1.14
50
1.67
1.59
1.51
1.46
1.41
1.35
1.31
1.28
1.24
1.2
1.16
55
1.74
1.67
1.59
1.52
1.46
1.41
1.37
1.32
1.28
1.24
1.2
HEAT REJECTION FACTOR FOR OPEN DRIVE COMPRESSORS, R407C
10
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
Compressor Factor Performance Data
Hermetic Reciprocating Compressors
TOTAL HEAT REJECTION FACTORS - HERMETIC RECIPROCATING COMPRESSORS
SCT
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
1.18
HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R22
35
1.68
1.61
1.55
1.49
1.43
1.38
1.34
1.3
1.25
1.21
40
1.73
1.65
1.59
1.53
1.47
1.41
1.36
1.32
1.27
1.23
1.2
45
1.78
1.7
1.63
1.57
1.51
1.44
1.4
1.35
1.3
1.26
1.22
50
1.84
1.75
1.68
1.61
1.55
1.48
1.43
1.39
1.33
1.29
1.25
55
1.91
1.82
1.74
1.67
1.6
1.53
1.48
1.43
1.37
1.32
1.28
HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R134a
35
1.6
1.55
1.48
1.42
1.37
1.33
1.29
1.24
1.21
1.18
40
1.67
1.61
1.53
1.47
1.42
1.36
1.32
1.27
1.24
1.2
45
1.73
1.66
1.59
1.52
1.46
1.41
1.36
1.3
1.27
1.23
50
1.8
1.72
1.64
1.58
1.51
1.45
1.41
1.34
1.3
1.26
1.86
1.77
1.7
1.63
1.56
1.49
1.44
1.39
1.343
1.29
55
HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R404A
35
1.70
1.66
1.61
1.55
1.50
1.44
1.39
1.34
1.29
1.25
1.21
40
1.78
1.73
1.68
1.62
1.56
1.50
1.44
1.39
1.33
1.28
1.24
45
1.87
1.82
1.76
1.69
1.63
1.56
1.50
1.44
1.37
1.32
1.27
50
2.00
1.95
1.88
1.80
1.72
1.64
1.57
1.50
1.43
1.37
1.33
55
2.20
2.11
2.05
1.94
1.85
1.75
1.67
1.59
1.50
1.44
1.37
HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R407B
35
1.87
1.76
1.68
1.61
1.53
1.48
1.42
1.36
1.32
1.27
1.23
1.19
40
1.95
1.85
45
2.06
1.96
1.78
1.7
1.57
1.53
1.47
1.41
1.36
1.31
1.25
1.23
1.86
1.76
1.68
1.61
1.55
1.47
1.41
1.34
1.3
1.25
50
2.2
55
2.33
2.07
1.97
1.88
1.76
1.68
1.6
1.53
1.47
1.41
1.35
1.31
2.21
2.11
1.98
1.87
1.77
1.69
1.6
1.55
1.46
1.4
1.35
1.18
HEAT REJECTION FACTOR FOR HERMETIC RECIPROCATING COMPRESSORS, R407C
35
1.71
1.63
1.57
1.5
1.44
1.39
1.34
1.3
1.25
1.21
40
1.76
1.68
1.61
1.55
1.49
1.42
1.37
1.33
1.28
1.23
1.2
45
1.81
1.73
1.66
1.59
1.53
1.46
1.42
1.36
1.31
1.27
1.23
50
1.9
1.81
1.71
1.64
1.58
1.5
1.45
1.41
1.35
1.3
1.26
55
1.98
1.88
1.8
1.7
1.63
1.56
1.51
1.45
1.39
1.34
1.29
Supporting Documentation
•
CL264.doc – KRC Air Cooled Condenser Handbook
Product Specification
•
Supported through
and heatload information
with product selection
•
Complementary Kirby Project Tool assists with project estimations
AUS - 13 23 50 | www.heatcraft.com.au | NZ - 0800 653 330 | www.heatcraft.co.nz
11
13 23 50
0800 653 330
heatcraft.com.au
heatcraft.co.nz
®
and ™ Registered Trade Mark and Trade Mark of Heatcraft Australia Pty Ltd
© Copyright 2016 Heatcraft Australia Pty Ltd
KIRBYKRCCOND_0816
The contents of this brochure are copyright protected and may not be reproduced in any form without the written consent of Heatcraft.
Recommendations and advice regarding the use of the products described in this publication are to be taken as a guide only and are given
without liability on the part of the company or its employees. As Heatcraft continually improves its product range and processes, Heatcraft reserves
the right to change product specifications without any prior notification. Please refer to the Heatcraft website for the latest version of this publication.
The purchaser should independently determine the suitability of the product for the intended use and application and that the product complies
with relevant standards. Heatcraft accepts no responsibility for loss or damage (direct or indirect and including consequential loss, loss of profits
or opportunity and economic loss) however arising which results from any errors or omissions in the information contained
in this publication or arising from the use or application of the information contained herein.

Similar documents

2012 Parts Manual.book

2012 Parts Manual.book DESCRIPTION Switch Float Rule-A-Matic Pump Bilge 1100 GPH Outlet Flange 12MP.OEM Outlet 12V Horn “H” Phase II 12V Horn Grill Off-white Screw-in Compass Ritchie Flush Mt-Dir Read

More information

AC axial fans - HyBlade® - ebm

AC axial fans - HyBlade®  - ebm 500-AJ03 -01 500-AJ03 -01 500-AJ01 -01

More information

2011 Parts Manual - Grady

2011 Parts Manual - Grady Thru Hull 1” w/ Reg Thread Thru Hull 1 1/8” w/ Reg Thread Rings Scupper Outer (White) Flap Rubber Scupper Washer Spacing 1 3/8”

More information