Configuring Wonderware`s Modbus Plus for the PCI
Transcription
Configuring Wonderware`s Modbus Plus for the PCI
8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional Tech Note 276 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional All Tech Notes and KBC D documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information. Topic#: t001064 C reated: September 2002 This Tech Note outlines Setting up a PCI-85 card with WinConX. Setting Up a PCI-85 Card with WinConX 1. Install the PCI-85 card. The Found New Hardware dialog box opens: 2. Locate and install the driver. 3. Start the MBX Driver Configuration utility from the WinConX folder. The MBX Driver Configuration dialog box opens: 4. Select the Device Configuration tab. 5. Click the New button. 6. Select the device type. https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 1/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional Select a Network Node for your new PCI-85 Card Make sure that the network node we have selected is not already been used by another PCL or card on this Modbus Plus network. 7. Run the MBX Demo utility from the WinConX folder to make sure we have configured the card correctly. There are two selections of interest. They are B and C. Selecting C will display the following information: The key items to note in this display are the Device Status and Node Address. Make sure that the Device Status is On-Line and Node Address is set to the correct node address. 8. Press any key on the keyboard to return to the MBX Demo selection menu. Selecting B will display this information: https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 2/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional The items noted in this display show what is currently on our Modbus Plus network. The I on the display represents our PCI-85 card and the U represent a PLC/device on our Modbus Plus network. Based on this display, our PCI-85 card currently has a node address of 1 and a PLC/device with a node address of 3. 9. Close the MBX Demo utility after verifying the PCI-85 card has been configured properly. Setting-Up Wonderware's Modbus Plus I/O Server 10. Start the Wonderware Modbus Plus I/O Server. Make sure that Wonderware's Modbus Plus I/O Server, Version 7,5,x,x or better, is installed. 11. Select Configure/Adapter Card Setting. The MBPLUS Adapter Card Settings dialog box opens: 12. Select Adapter Number. This is based on the configuration in WinConX. In this case, the adapter number was set at 0. 13. Select OK on the MBPLUS Adapter Card Settings dialog box. The MBPLUS dialog box opens: https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 3/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional 14. Click Yes to restart your computer. 15. Start Wonderware's Modbus Plus I/O Server. 16. Select Configure/Topic Definition. 17. Click New to create a new topic. 18. In the Topic Name field type in the name Quantum. (Any name can be entered.) 19. Click the drop-down arrow next to the Adapter Card Name field, and select the the newly created adapter card name. 20. For Slave Type, select 6 Digit. 6 Digit is select because we will be polling data from a PLC device that will support 6 digit addressing. Example: a Quantum PLC. 21. In the Slave Path field, type in 3.0.0.0.0. Our PLC device has a node address of 3. 22. Click OK when finished. https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 4/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional Testing Connection to PLC/Device To quickly test to make sure our Wonderware Modbus Plus I/O server is configured correctly, we need to use WWClient. 23. Select Programs/FactorySuite/Common/WWClient. 24. Select Connection/Create. The Create Connection dialog box opens: 25. Select the Connection Type of DDE or IOT (a.k.a., SuiteLink). 26. Click in the Node field and type Localhost as the node name. 27. Click in the Application field and type in mbplus. 28. Click in the Topic field and type in Quantum. Quantum is the topic created earlier. 29. Click Create, then Done. After creating a connection with WWClient, check the Wonderware Modbus Plus I/O server. It should look similar to the following dialog box. 30. Ensure the Status is GOOD. Polling Data From The PLC Device https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 5/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional 31. Click in the Item field on WWClient. The Item dialog box opens: 32. Click in the Item field and enter the address 400001. We know this address exists on our PLC device. 33. Click the AdviseEx button. 34. Click Done when finished. The Wonderware Client dialog box opens: The column with 0x00c0 indicates we are receiving good data. I. Bui Tech Notes are published occasionally by Wonderware Technical Support. Publisher: Invensys Systems, Inc., 26561 Rancho Parkway South, Lake Forest, C A 92630. There is also technical information on our software products at Wonderware Technical Support For technical support questions, send an e-mail to [email protected]. back to top https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 6/7 8/23/13 Configuring Wonderware's Modbus Plus for the PCI-85 Card in Windows 2000 Professional ©2013 Invensys Systems, Inc. All rights reserved. No part of the material protected by this copyright may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, broadcasting, or by anyinformation storage and retrieval system, without permission in writing from Invensys Systems, Inc. Terms of Use. https://wdnresource.wonderware.com/support/kbcd/html/1/t001064.htm 7/7
Similar documents
Configuring the AB1784KT I/O Server With the PKTX Card
- Release 7.5.0.4 or greater of the AB1784KT I/O Server. Note 1: Firmware files may no longer be included with the PKTX Card. Please contact Rockwell software for a copy of them. If you install RSL...
More informationConfigure DASABDHPlus to Work with the 1784
Configure DASABDHPlus to Work with the 1784-PKTx Adapter All Tech Notes and KBC D documents and software are provided "as is" without warranty of any kind. See the Terms of Use for more information.
More information