Model 007-IFC™ Cartridge Circulator

Transcription

Model 007-IFC™ Cartridge Circulator
Water Circulation
Pumps & Circulators
Model 007-IFC™ Cartridge Circulator
The 007-IFC now includes an Integral Flow Check, saving installation costs while improving system performance.
The patented IFC replaces a separate in-line flow check and prevents gravity flow when the heating zone is not
operating. The 007-Z-IFC adds the IFC feature to our Priority Zoning circulator with built-in transformer relay,
and priority switch to make it the best choice when zoning with circulators.
H YDRONIC C OMPONENTS & S YSTEMS
©Taco Catalog # : 100-6.9
Supersedes: 100-6.9 Dated 10/1/02
Effective Date: 09/1/03
Printed in USA
Submittal Data # 101-077
Supersedes: 10/1/02
Submittal Data Information
Model 007-IFC™ Cartridge Circulator
Features
Effective: 09/1/03
Application
• Integral Flow Check (IFC) Patent# 5,664,939
Prevents gravity flow
Eliminates separate in-line flow check
Reduces installed cost, easy to service
Improved performance vs. In-line flow
checks
• Unique replaceable cartridge-Field serviceable
• Unmatched reliability-Maintenance free
• Quiet, efficient operation
• Direct drive-Low power consumption
• Self lubricating, No mechanical seal
• Standard high capacity output-Compact design
• Wide range of applications
• Cast Iron construction, Flanged connections
The 007-IFC with an Integral Flow Check is designed to reduce installation costs when zoning with
“00” circulators on Hydronic or Radiant heating, Hydro-Air Fan Coils or Indirect water heaters.
By locating the patented IFC inside the pump casing, a separate in-line flow check is eliminated,
reducing installation costs. The reduced pressure drop of the IFC, increases the 007 flow performance
up to 240% over in-line check valves. Both the IFC and cartridge are easily accessed for service
instead of replacing the entire unit. The 007-Z-IFC combines the circulator, flow-check and patented
Priority Zoning control with built-in transformer, relay and priority switch in one complete, compact
package to make it ideal for zoning. Available in Cast Iron construction with flanged connections.
Pump Dimensions & Weights
Model
Casing
007-F5-IFC Cast Iron
007-ZF5-IFC Cast Iron
A
in. mm
B
in. mm
7
7
4-1/2
4-1/2
178
178
114
114
C
in. mm
3-3/16
3-3/16
81
81
in.
2-15/16
3-5/8
D
E
F
Ship Wt.
mm in. mm in. mm lbs. Kg
75
92
5
127
5-9/16 143
6-3/8
6-3/8
162
162
9
9
Mounting Positions
Materials of Construction
Casing (Volute): Cast Iron
Integral Flow Check:
Body, Plunger....Acetal
O-ring Seals......Nitrile
Spring.................Stainless Steel
Stator Housing: Steel
Cartridge:
Stainless Steel
Impeller:
Non-Metallic
Shaft:
Ceramic
Bearings:
Carbon
O-Ring & Gaskets: EPDM
Model Nomenclature
F – Cast Iron, Flanged
IFC – Integral Flow Check
Standard
Flange Orientation
Electrical Data
Model
007-F5-IFC
007-ZF5-IFC
Optional
Volts
Hz
115
115
60
60
Ph Amps
1
1
.71
.71
RPM
HP
3250
3250
1/25
1/25
Motor Permanent Split Capacitor
Type
Impedance Protected
Motor
Options 220/50/1, 220/60/1, 230/60/1, 100/110/50/60/1
Performance Field - 60Hz
Variations:
Z – Zoning Circulator
J – Bronze Cartridge with Cast Iron Casing
Performance Data
Flow Range: 0 - 12.5 GPM
Head Range: 0 - 11 Feet
Minimum Fluid Temperature: 40˚F (4˚C)
Maximum Fluid Temperature: 240°F (115˚C)
Maximum Working Pressure: 125 psi
Connection Sizes: 3/4”, 1”, 1-1/4”, 1-1/2” Flanged
FOR INDOOR USE ONLY
H YDRONIC C OMPONENTS & S YSTEMS
Taco Inc., 1160 Cranston Street, Cranston, RI 02920 / (401) 942-8000 / Fax (401) 942-2360
Taco (Canada) Ltd., 6180 Ordan Drive, Mississauga, Ontario L5T 2B3 / (905) 564-9422 / Fax (905) 564-9436
www.taco-hvac.com
OK if over
20 psi
4.0
4.0