GFC SERIES Low ProFileTM 400 Hz AND 28 VDC
Transcription
GFC SERIES Low ProFileTM 400 Hz AND 28 VDC
GFC SERIES Low ProFileTM 400 Hz AND 28 VDC GROUND POWER UNIT APPLICATION: Since its beginning in 1960, Unitron has specialized in the design and development of reliable solid-state power systems. Through an innovative design, advanced self-diagnostic systems (BITE) and modular construction, Unitron products assure maximum power availability and minimal repair time. The Low ProFileTM Series includes 400 Hz and 28 VDC converters designed to provide aircraft ground power in “low profile” applications, such as under passenger boarding bridges, in maintenance hangars, or on flight lines. The dual output AC/DC GPU provides simultaneous AC and DC power from a single unit. Because a single unit can do the work of two, Unitron’s AC/DC GPU reduces operating and maintenance costs, and saves valuable space in the hangar or on the ramp. In addition to fixed GPUs, Unitron offers 400 Hz, 28 VDC and combination AC/DC units in towable, mobile and bridge-mounted configurations. HORIZONTAL CONFIGURATION OPTIONS: STANDARD FEATURES: MIL-STD-704F, ARP 5015, DFS 400 and ISO 6858 Compliant Indoor/Outdoor (Hangar/Ramp) Use Automatic Input Line Monitoring Automatic Line Drop Compensation (ALDC) Emergency Mushroom “OFF” Switch Dual Output with Individual Safety Disconnect Alternate Input Voltages Available (specify) Input Frequency 50 Hz AC Output Power Cable with Plug (30 or 60 foot lengths) DC Output Power Cable with Plug (20, 30 or 60 foot lengths) Front Panel AC and DC Voltage Adjust (± 15%) No Break Power Transfer (NBPT) Compatible Low Input Current Distortion (12-pulse) 300% Overload (dependent on rating) Alternate Mounting Configurations Available Built-in Maintenance Diagnostics Analog Control Panel MECHANICAL SPECIFICATIONS: Output Voltage and Current Monitoring Size: See Figure 1 Weight: 37.5 kVA = 865 lbs. (392 kgs.) 60.0 kVA = 950 lbs. (431 kgs.) 75.0 kVA = 995 lbs. (451 kgs.) 90.0 kVA = 1075 lbs. (487 kgs.) Construction: Indoor/Outdoor Cooling: Forced Convection Internal Elapsed Time Meter Front Panel Summary Fault Indicators **This product was manufactured in a plant whose quality management system is registered to ISO 9001:2000. GENERAL SPECIFICATIONS AC INPUT: Voltage Frequency Phase Rotation Protection Inrush Current 480 volts, +10%, -15%, 3Ø, 3 wire plus ground 60 Hz ± 10% Any Over/undervoltage, loss of phase, overcurrent, short circuit No greater than 100% of full load current 37.5, 60, 75 or 90 kVA (specify) 150% for 5 min., 200% for 20 sec. 115/200 volts, 3Ø, 4 wire, grounded neutral ± 1.0% under all conditions of line, balanced loads and temperature IAW MIL-STD-704E 400 Hz ± 0.01% under all conditions of line, load and temperature None ± 2° for balanced loads 2.0% maximum Overload, short circuit, over/under voltage and safety disconnect ENVIRONMENTAL: Acoustical Noise Temperature Range Full Rated Load Overload Engine Start Capacity Voltage Voltage Regulation 450 amps continuous 600 amps for 30 minutes at 20% duty cycle Adjustable up to 2000 amps for 20 seconds at 10% duty cycle 28 VDC, 2 wire, grounded negative 100% continuous rated AC OUTPUT: Power Rating Overload Voltage Voltage Regulation Voltage Transients Frequency Regulation Frequency Transients Phase Angle Regulation Harmonic Distortion Protection DC OUTPUT: 65 dBA maximum at 5 feet -40°C to +55°C load and ± 10% input voltage ± 0.05% No load to rated load with nominal input voltage IAW ISO 6858 Overload with nominal input voltage Voltage Adjust See Start Mode literature for Model 420RDC 28 VDC ± 10% Current Limit Adjust Protection 200 to 2000 amps Overload, short circuit, overvolt- age and safety disconnect ENERGY FACTORS: Efficiency Energy Efficiency Ratio 95% typical at full load, 93% typical at half load; varies depending on configuration and rating 20.0 typical FIGURE 1 REV NC GFC SERIES Low ProFileTM AC/DC GROUND POWER UNIT (GPU) REV. C