DCT RIALTO LOGISTICS CENTER
Transcription
DCT RIALTO LOGISTICS CENTER
FOR LEASE : 312,130 SF DCT RIALTO LOGISTICS CENTER 1979 W. Renaissance Parkway, Rialto, CA BUILDING HIGHLIGHTS 312,130 SF Crossdock Building, Part of Larger 927,575 SF 3,354 SF Spec Office 32’ Minimum Clear Height (1st column) 38 Dock High Doors (9’ x 10‘) 2 Ground Level Doors (12’ x 14‘) 71 Trailer Parking Positions 141 Employee Parking Positions 235’/185’ Concrete Truck Courts 52’ x 60’ Column Spacing 3% Skylights 7” Thick 4000 PSI Floor Slab ESFR Sprinkler System CONTACT Michael Chavez, Lee & Associates 909.373.2900 • [email protected] David Nguyen, Lee & Associates 909.373.2725 • [email protected] Mark Zorn, Colliers International 909.937.6318 • [email protected] FOR LEASE : 312,130 SF DCT RIALTO LOGISTICS CENTER 1979 W. Renaissance Parkway, Rialto, CA CONTACT Michael Chavez, Lee & Associates 909.373.2900 • [email protected] David Nguyen, Lee & Associates 909.373.2725 • [email protected] Mark Zorn, Colliers International 909.937.6318 • [email protected] FOR LEASE : 312,130 SF DCT RIALTO LOGISTICS CENTER 1979 W. Renaissance Parkway, Rialto, CA SPEC OFFICES 3,354 SF CONTACT Michael Chavez, Lee & Associates 909.373.2900 • [email protected] David Nguyen, Lee & Associates 909.373.2725 • [email protected] Mark Zorn, Colliers International 909.937.6318 • [email protected] FOR LEASE : 312,130 SF DCT RIALTO LOGISTICS CENTER 1979 W. Renaissance Parkway, Rialto, CA Building Specifications BUILDING HIGHLIGHTS SIZE 312,130 SF (Part of larger 927,575 SF) • Awarded LEED Silver OFFICE 3,354 SF spec office (expandable) • Corporate neighbors: Under Armour, Solo Cup, OHL Logistics, Target, Black & Decker and Distribution Alternatives LOADING 38 (9’ x 10’) dock high doors 2 (12’ x 14’) ground level doors • Minutes to 210 freeway CLEAR 32’ minimum clear height (1st column) PARKING 141 employee positions 71 trailer positions NET EXPENSES $0.103 PSF (estimated) POWER 800 amps @ 277/480 volts, 3 phase TRUCK COURT 235’/185’ LIGHTING T-5 fixtures with motion sensors (20’ foot candles measured 36’ above finished floors) COLUMN SPACING 52’ x 60’ SPRINKLER ESFR system with K17 heads at 52 PSI CONTACT Michael Chavez, Lee & Associates 909.373.2900 • [email protected] David Nguyen, Lee & Associates 909.373.2725 • [email protected] Mark Zorn, Colliers International 909.937.6318 • [email protected]
Similar documents
Chinook Building at DCT White River Corporate Center
Matt McGregor, Colliers International 206.624.7401 • [email protected]
More information