Catalyst 6500 Series DFC Memory Installation Note

Transcription

Catalyst 6500 Series DFC Memory Installation Note
Catalyst 6500 Series DFC Memory Installation
Note
Product numbers:
MEM-DFC-128M=, MEM-DFC-256M=, MEM-DFC-512M= (for WS-F6K-DFC)
MEM-XCEF720-512M= (for WS-F6K-DFC3A, WS-F6700-DFC3A, WS-F6700-DFC3B)
MEM-XCEF720-1GB= (for WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL)
This publication provides procedures for installing memory on the following Catalyst 6500 series
Distributed Forwarding Cards (DFCs):
•
WS-F6K-DFC
•
WS-F6K-DFC3A
•
WS-F6700-DFC3A
•
WS-F6700-DFC3B
•
WS-F6700-DFC3BXL
Note
For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory
module is located on the base WS-X67xx module, under the DFC3 daughtercard. You must
remove the daughtercard from the module to upgrade the memory.
Corporate Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2001–2004 Cisco Systems, Inc. All rights reserved.
Contents
Contents
This publication contains these sections:
•
Safety Overview, page 2
•
Required Tools, page 3
•
Installation Guidelines, page 3
•
Verifying the DFC Memory, page 4
•
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only),
page 5
•
Removing the SODIMM, page 9
•
Installing the SODIMM, page 13
•
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only),
page 14
•
Related Documentation, page 18
•
Obtaining Documentation, page 19
•
Documentation Feedback, page 19
•
Obtaining Technical Assistance, page 20
•
Obtaining Additional Publications and Information, page 21
Safety Overview
Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may
harm you. A warning symbol precedes each warning statement.
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device. Statement 1071
SAVE THESE INSTRUCTIONS
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing. Statement 1034
Catalyst 6500 Series DFC Memory Installation Note
2
78-12409-04
Required Tools
Required Tools
These tools are required to upgrade the memory on the Catalyst 6500 series DFC:
Caution
•
3/16-inch flat-blade screwdriver for the captive installation screws on the module on which the DFC
is installed
•
WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL only—Number 1 Phillips-head
screwdriver for the screws and cap nuts that fasten the DFC3 to the WS-X67xx module
•
Antistatic mat or antistatic foam
•
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, field-replaceable units (FRUs), and spares
Always use an ESD wrist strap when handling modules or coming into contact with internal components.
Installation Guidelines
Observe the following cautions when upgrading the memory on a DFC:
Caution
Always use an ESD wrist strap when handling modules or coming into contact with internal
components.
Caution
During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do
not directly touch the backplane with your hand or any metal tool, or you could shock
yourself.
Caution
SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD
damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or
traces (the metal fingers along the connector edge of the SODIMM).
Caution
When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you
will have to return the DFC to the factory for repair.
Caution
Use care not to damage the connectors on the module. If you damage a connector, it will be
necessary to return the module to Cisco for repair.
Caution
You must install screws in all available standoffs. The screws provide grounding between the
DFC3 and the module. Failure to install all screws will invalidate the safety approvals and
pose a risk of fire and electrical hazard.
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
3
Verifying the DFC Memory
Verifying the DFC Memory
Table 1 lists the default memory configurations and available upgrades.
Table 1
Memory Configurations
DFC version
Default Memory
Upgradeable Memory
Part Number
WS-F6K-DFC3
128 MB
256 MB
512 MB
MEM-DFC-256M=
MEM-DFC-512M=
WS-F6K-DFC3A
512 MB
No upgrade available
–
WS-F6700-DFC3A
256 MB
512 MB
1 GB
MEM-XCEF720-512M=
MEM-XCEF720-1GB=
WS-F6700-DFC3B
256 MB
512 MB
1 GB
MEM-XCEF720-512M=
MEM-XCEF720-1GB=
WS-F6700-DFC3BXL
1 GB
No upgrade available
–
To verify the memory configuration on the DFC, enter the remote command module mod show
memory summary command, where mod is the module with an installed DFC. Add the processor and
I/O totals to get the total memory for the DFC.
This example shows how to check the total memory on the DFC on a fabric-enabled module in slot 9:
Router# remote command module 9 show memory summary
Router-dfc9#
Processor
I/O
Head
31C5BFC0
E000000
Total(b)
205144128
33554440
Used(b)
127792712
5987288
Free(b)
77351416
27567152
Lowest(b) Largest(b)
65520524 64818696
27567152 27567100
...<output truncated>
Router#
The above example shows the total memory on the DFC is 256 MB.
Catalyst 6500 Series DFC Memory Installation Note
4
78-12409-04
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B,
WS-F6700-DFC3BXL Only)
For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory module is
located on the base WS-X67xx module, under the DFC3. To upgrade the DFC3 memory, you must first
remove the DFC3 from the module.
To remove a DFC3, follow these steps:
Warning
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution
when servicing. Statement 1034
Caution
During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly
touch the backplane with your hand or any metal tool, or you could shock yourself.
Step 1
Remove the module from the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module
Installation Guide for removal instructions.)
Step 2
Place the module on an antistatic mat or foam, with the front of the module facing toward you.
Step 3
Use a Phillips-head screwdriver to remove the securing screws and the two cap nuts. (See Figure 1.)
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
5
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Removing the Securing Screws and Cap Nuts
WS-X5530
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
Step 4
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
99719
Figure 1
Partially install the cap nut, as shown in Figure 2, about 3 turns so that there is a space of about 1/8 inch
(3.175 mm) between the bottom of the cap nut and the top of the DFC3. The cap nut acts as a stop when
you unseat the connector so that the DFC3 does not move horizontally and cause damage to the module.
Catalyst 6500 Series DFC Memory Installation Note
6
78-12409-04
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Figure 2
Partially Installing the Cap Nut
Cap nut
120047
Appx 1/8 inch
Step 5
With your left hand, lift slightly at the location shown in Figure 3. While lifting with your left hand, rock
the DFC3 up and down with your right hand, no more than half an inch in either direction, to unseat the
DFC3 from the module.
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
7
Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Figure 3
Unseat the DFC3 from the Module
Lift here
Rock up
and down
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
120048
WS-X5530
Step 6
Remove the cap nut.
Step 7
Hold the DFC3 with both hands, and gently lift the DFC3 straight up from the module. (See Figure 4.)
Catalyst 6500 Series DFC Memory Installation Note
8
78-12409-04
Removing the SODIMM
Removing the DFC3 from the Module
WS-X5530
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Step 8
Place the removed DFC3 on an antistatic mat or antistatic foam pad.
Step 9
Proceed to the “Removing the SODIMM” section on page 9.
71
18
19
20
21
22
23
24
120049
Figure 4
Removing the SODIMM
Caution
During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly
touch the backplane with your hand or any metal tool, or you could shock yourself.
To remove the existing SODIMM, follow these steps:
Step 1
Make sure that you take the necessary precautions to prevent ESD damage.
Step 2
Remove the module with the DFC or DFC3A from the system. (Refer to the Catalyst 6500 Series Module
Installation Guide for removal instructions.)
Step 3
Place the module on an antistatic mat or pad.
Step 4
Locate the SODIMM. (See Figure 5 for the WS-F6K-DFC, see Figure 6 for the WS-F6K-DFC3A, and
see Figure 7 for the WS-X6700-DFC3A.)
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
9
Removing the SODIMM
Figure 5
Location of SODIMM on a WS-F6K-DFC
SDRAM
SODIMM
TUS
STA 2
1
3
LINE 1
Figure 6
5
4
2
7
6
LINE 3
LINE
4
LINE 5
LINE
6
LINE
11
9
10
8
LINE 7
8
LINE 9
LINE
13
12
10
LINE
15
14
LINE 11
12
51542
WS-X5530
16
LINE 13
LINE
14
LINE 15
LINE
16
LINE
Location of SODIMM on a WS-F6K-DFC3A
S
S
3
3
5
SS
5
0
3
5
0
3
5
0
WS-X5530
Catalyst 6500 Series DFC Memory Installation Note
10
78-12409-04
Removing the SODIMM
Figure 7
Location of SODIMM on a WS-X67xx Module for the DFC3A, DFC3B, and DFC3BXL
DDR SDRAM
SODIMM
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
113340
WS-X5530
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
11
Removing the SODIMM
Step 5
Release the spring clips from the SODIMM, and release the SODIMM from the socket. (See Figure 8.)
Figure 8
Releasing the SODIMM Spring Clips
Pull the tabs away with
your thumbs, bracing your
forefingers against the
rails. The memory module
will be released. Then raise
the memory module to
a vertical position.
51543
Memory module
Step 6
Caution
Step 7
When both ends of the SODIMM are released from the socket, grasp the ends of the SODIMM with your
thumb and forefinger, and pull the SODIMM completely out of the socket.
SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage,
handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal
fingers along the connector edge of the SODIMM). (See Figure 9.)
Place the SODIMM in an antistatic container to protect it from ESD damage.
This completes the SODIMM removal procedure. Proceed to the “Installing the SODIMM” section on
page 13 to install the new SODIMM.
Catalyst 6500 Series DFC Memory Installation Note
12
78-12409-04
Installing the SODIMM
Installing the SODIMM
Caution
SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage,
handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal
fingers along the connector edge of the SODIMM). (See Figure 9.)
Handling a SODIMM
51544
Figure 9
Follow these steps to install the new SODIMM:
Step 1
Remove a new SODIMM from the antistatic container.
Step 2
Hold the SODIMM with the component side up and with the connector edge (the metal fingers) away
from you.
Step 3
Hold the sides of the SODIMM between your thumbs and forefingers. (See Figure 9.)
Step 4
Tilt the SODIMM to approximately the same angle as the socket, and insert the connector edge into the
socket.
Caution
When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you will have
to return the DFC to the factory for repair.
Step 5
Press the SODIMM down until it is secured by the spring clips. (See Figure 10.)
Installing the SODIMM
28736
Figure 10
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
13
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Step 6
When the SODIMM is installed, check the two alignment holes, and ensure that the spring retainer is
visible. If it is not, the SODIMM is not seated properly. If any SODIMM appears misaligned, carefully
remove it and reseat it in the socket. Push the SODIMM firmly back into the socket until the retainer
springs snap into place.
Step 7
If you upgraded the memory on the WS-F6700-DFC3A, WS-F6700-DFC3B, or WS-F6700-DFC3BXL,
you need to reinstall the DFC3. Proceed to the “Installing the DFC3 (WS-F6700-DFC3A,
WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)” section on page 14 to install the DFC3.
Otherwise, reinstall the module. (Refer to the Catalyst 6500 Series Module Installation Guide for
removal instructions.)
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B,
WS-F6700-DFC3BXL Only)
To install the DFC3 on a WS-X67xx module, follow these steps:
Caution
Step 1
During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly
touch the backplane with your hand or any metal tool, or you could shock yourself.
Align the mounting holes on the DFC3 (see Figure 11) with the male standoffs on the module.
(See Figure 12.) Make sure that the remaining mounting holes on the DFC3 are aligned with the
remaining standoffs.
Figure 11
Mounting Holes on the DFC3
99361
Align with the male standoffs
on the module
Catalyst 6500 Series DFC Memory Installation Note
14
78-12409-04
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Figure 12
Male Standoff Locations on the WS-X67xx Module
Male standoffs
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
99716
WS-X5530
STATUS
1
Step 2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
Ensure that the connectors on the DFC3 are aligned with the connectors on the module. Figure 13 shows
the connectors on the underside of the DFC3.
Figure 13
DFC3A Connectors
99363
Connectors
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
15
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Step 3
Apply pressure to the area shown in Figure 14 to seat the power connector.
Figure 14
Seating the Power Connector
Apply pressure
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
Caution
Step 4
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
99718
WS-X5530
Use care not to damage the connectors on the module. If you damage a connector, it will be necessary
to return the module to Cisco for repair.
Apply pressure to the location shown in Figure 15 to fully seat the DFC3 on the module.
Catalyst 6500 Series DFC Memory Installation Note
16
78-12409-04
Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)
Figure 15
Seating the DFC3 on the Module
Apply pressure
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
Step 5
Caution
Note
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
99717
WS-X5530
Use a Phillips-head screwdriver to install the securing screws and the two cap nuts. (See Figure 16.)
You must install screws in all available standoffs. The screws provide grounding between the DFC3 and
the module. Failure to install all screws will invalidate the safety approvals and pose a risk of fire and
electrical hazard.
You should visually verify that there are standoffs beneath the mounting holes before installing the
securing screws.
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
17
Related Documentation
Installing the Securing Screws and Cap Nuts
WS-X5530
WS-X6724-SFP
24PORT GIGABIT ETHERNET - SFP
STATUS
1
Step 6
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
71
18
19
20
21
22
23
24
99719
Figure 16
Install the module in the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module
Installation Guide for installation instructions.)
Related Documentation
These documents are available for the Catalyst 6500 series switches:
•
Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches
•
Catalyst 6500 Series Switch Installation Guide
•
Catalyst 6500 Series Switch Module Installation Guide
•
Catalyst 6500 Series Switch Software Configuration Guide
•
Catalyst 6500 Series Switch Command Reference
•
Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide
•
Catalyst 6500 Series Switch Cisco IOS Command Reference
•
Catalyst 6500 Series DFC/DFC3A Installation Note
•
Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note
Catalyst 6500 Series DFC Memory Installation Note
18
78-12409-04
Obtaining Documentation
Obtaining Documentation
Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several
ways to obtain technical assistance and other technical resources. These sections explain how to obtain
technical information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation at this URL:
http://www.cisco.com/univercd/home/home.htm
You can access the Cisco website at this URL:
http://www.cisco.com
You can access international Cisco websites at this URL:
http://www.cisco.com/public/countries_languages.shtml
Ordering Documentation
You can find instructions for ordering documentation at this URL:
http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm
You can order Cisco documentation in these ways:
•
Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from
the Ordering tool:
http://www.cisco.com/en/US/partner/ordering/index.shtml
•
Nonregistered Cisco.com users can order documentation through a local account representative by
calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in
North America, by calling 800 553-NETS (6387).
Documentation Feedback
You can send comments about technical documentation to [email protected].
You can submit comments by using the response card (if present) behind the front cover of your
document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
19
Obtaining Technical Assistance
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco
Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical
Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical
Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service
contract, contact your reseller.
Cisco Technical Support Website
The Cisco Technical Support Website provides online documents and tools for troubleshooting and
resolving technical issues with Cisco products and technologies. The website is available 24 hours a day,
365 days a year at this URL:
http://www.cisco.com/techsupport
Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password.
If you have a valid service contract but do not have a user ID or password, you can register at this URL:
http://tools.cisco.com/RPF/register/register.do
Submitting a Service Request
Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3
and S4 service requests are those in which your network is minimally impaired or for which you require
product information.) After you describe your situation, the TAC Service Request Tool automatically
provides recommended solutions. If your issue is not resolved using the recommended resources, your
service request will be assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at
this URL:
http://www.cisco.com/techsupport/servicerequest
For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone.
(S1 or S2 service requests are those in which your production network is down or severely degraded.)
Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business
operations running smoothly.
To open a service request by telephone, use one of the following numbers:
Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553 2447
For a complete list of Cisco TAC contacts, go to this URL:
http://www.cisco.com/techsupport/contacts
Definitions of Service Request Severity
To ensure that all service requests are reported in a standard format, Cisco has established severity
definitions.
Severity 1 (S1)—Your network is “down,” or there is a critical impact to your business operations. You
and Cisco will commit all necessary resources around the clock to resolve the situation.
Catalyst 6500 Series DFC Memory Installation Note
20
78-12409-04
Obtaining Additional Publications and Information
Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your
business operation are negatively affected by inadequate performance of Cisco products. You and Cisco
will commit full-time resources during normal business hours to resolve the situation.
Severity 3 (S3)—Operational performance of your network is impaired, but most business operations
remain functional. You and Cisco will commit resources during normal business hours to restore service
to satisfactory levels.
Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or
configuration. There is little or no effect on your business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is available from various online
and printed sources.
•
Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Visit
Cisco Marketplace, the company store, at this URL:
http://www.cisco.com/go/marketplace/
•
The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as
ordering and customer support services. Access the Cisco Product Catalog at this URL:
http://cisco.com/univercd/cc/td/doc/pcat/
•
Cisco Press publishes a wide range of general networking, training and certification titles. Both new
and experienced users will benefit from these publications. For current Cisco Press titles and other
information, go to Cisco Press at this URL:
http://www.ciscopress.com
•
Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and
networking investments. Each quarter, Packet delivers coverage of the latest industry trends,
technology breakthroughs, and Cisco products and solutions, as well as network deployment and
troubleshooting tips, configuration examples, customer case studies, certification and training
information, and links to scores of in-depth online resources. You can access Packet magazine at this
URL:
http://www.cisco.com/packet
•
iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies
learn how they can use technology to increase revenue, streamline their business, and expand
services. The publication identifies the challenges facing these companies and the technologies to
help solve them, using real-world case studies and business strategies to help readers make sound
technology investment decisions. You can access iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
•
Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering
professionals involved in designing, developing, and operating public and private internets and
intranets. You can access the Internet Protocol Journal at this URL:
http://www.cisco.com/ipj
•
World-class networking training is available from Cisco. You can view current offerings at
this URL:
http://www.cisco.com/en/US/learning/index.html
Catalyst 6500 Series DFC Memory Installation Note
78-12409-04
21
Obtaining Additional Publications and Information
This document is to be used in conjunction with the documents listed in the “Related Documentation” section.
CCSP, the Cisco Square Bridge logo, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing
the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP,
CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the
Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, GigaDrive, GigaStack,
HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the
Networkers logo, Networking Academy, Network Registrar, Packet, PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, Registrar, ScriptShare,
SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are
registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (0406R)
Copyright © 2001–2004 Cisco Systems, Inc. All rights reserved.
Catalyst 6500 Series DFC Memory Installation Note
22
78-12409-04