GeneralAire Guide to Indoor Air Quality Products
Transcription
GeneralAire Guide to Indoor Air Quality Products
<#> A1 The air we breathe indoors is 2 to 5 times more polluted than the air we breathe outdoors! Dry air is like a sponge, The average person spends 90% of a 24 hour day indoors. Our health could be at risk! Improper humidity levels, dangerous gas molecules, mold spores, germs, and microscopic particulates all affect our long term health and comfort. GeneralAire has the answer to significantly reduce harmful airborne contaminants in the air we breathe. Install a GeneralAire Humidifier, UVC Photocatalytic Air Purifier, HEPA Air Cleaner, and a MAC Series Air Cleaner for a complete indoor air quality system. it soaks up moisture from wherever it can find it. When air becomes too dry, moisture is drawn from people, plants, wood, wool, cotton and even your pets. The results can be damaging, expensive and uncomfortable. Humidity For Comfort Research has shown that 40% to 60% relative humidity is ideal for today’s homes. Outside this range, bacteria, fungi, viruses and mites thrive. Proper relative humidity provides a comfortable environment for your woodwork, your furniture, your plants, your pets and especially you and your family. Optimum Zone Bacteria Viruses Fungi Mites Respiratory Infections Allergic Rhinitus & Asthma Ozone Production 10 20 30 35 40 % Relative Humidity 50 60 70 80 90 Humidity Can Save Money Too! The Center for Disease Control and Prevention categorizes indoor air pollution into three phases: Particulates, Gases, and Germs. 35% of allergic reactions are caused by the levels of particulates in the air we breathe indoors. 34% of allergic reactions are caused by levels of microorganisms (germs) in the air we breathe indoors. 31% of allergic reactions are caused by the amount of chemical gases found present in the air we breathe in our homes and at work. 34% Germs Bioaerosols Bacteria, Viruses, Fungi, Pathogens and Allergens 31% Gases Volatile Organic Compounds (VOC) Gas molecules, Odors, Toxins 35% Particulates Organic and Inorganic Particulate dust, smoke, pollen, animal dander and dust mites As moisture evaporates from your body, it cools the surface of your skin, making you feel cooler. Controlled humidity from GENERALAire’s Elite Steam Humidifier allows you the luxury of dialing the thermostat back, thus reducing annual heating bills. For example, 68°F at 40% relative humidity feels just as warm as 74°F at 20% relative humidity. Setting your thermostat back by as little as three degrees can reduce annual heating bills by as much as 5%. How much Humidity is right? Calculate the total cubic feet of house • Total square footage X Average ceiling height Calculate the Load (lbs/hr) • Total cubic feet X Table desired condition • Gallons per day = Load (lbs/hr) X 2.88 • Add 5% to humidity load per fireplace Pounds of Moisture per Cubic Foot (based on .5 air changes per hour) Indoor Air Temp ˚F Indoor RH% 35% 40% 45% 50% 68 0.00015 0.00018 0.00021 0.00024 70 0.00017 0.00020 0.00023 0.00026 72 0.00019 0.00022 0.00025 0.00028 Table of Contents Whole-House Humidifiers Improve comfort indoors and maintain a healthy environment. Quality, Style and Commitment goes into every box so you can relax. Browse the selection of Steam, Flow-Through, and Reservoir Type Models to meet your needs. Whole-House Air Cleaners High efficiency air filtration options for clean, healthier air. You can expect relief from indoor allergic reactions due to airborne submicronic particulates with 99.97% efficiency at .30 micron with H.E.P.A. filtration. Other models available at MERV 11, 10, and 8 for your efficiency options. Energy & Heat Recovery Ventilation Improve your indoor air quality introducing fresh outside air for better home comfort. An impressive selection of GeneralAire control options await your review and approval for an impressive installation. Whole-House Dehumidification Protect and control your indoor air from those sticky hot summer months for an efficient, comfortable, healthier home. Indoor air can become wet and musty in the summer months. We have an efficient whole-house solution for you to review. Ultraviolet Air Treatment Breathe a little easier and significantly reduce levels of unwanted airborne microorganisms and gaseous contaminants with ultraviolet air treatment. Impressive ultraviolet technology methods are applied in a whole-house unit to eliminate indoor air pollution like the powerful purifying rays of the sun outdoors. Customer Service & Technical Support Contact for assistance Monday through Friday 8:00 am to 4:30 pm eastern standard time Toll Free 866-476-5101 [email protected] 2 Elite Series Steam Humidifiers We all have an investment in our health, homes and its furnishings. Protecting those investments from the dry air may not seem like an important task, but the effects of dry air are astounding: • • • • • Dry nose and throat Itchy dry skin Cracking of expensive woodwork and floors Damage to household furnishings Static electricity shocks that can damage computers, VCRs and other electronic equipment • Dry air pulls moisture from delicate membranes in your nose, throat and lungs and food doesn’t taste as good • Sleeping becomes difficult and your mental concentration is affected Duct Mount Kit Remote Blower Kit DS Model Kit selection required *Shown with cover removed RS Model *Shown with cover Standard Water Conductivity Models: 350 to 1250 Microsiemens LC designates Low Conductivity Models: 125 to 500 Microsiemens *DS models require kit selection for installation 610 Digital Thermohygrometer 3 35662-30 EZTestr11 Conductivity Tester Model RS 15 Elite Series Steam Humidifier • Integral Room Steam Blower • Automatic Humidistat • LCD user interface • Drain tempering • AHU Fan Relay • Electrode Steam Generating Technology Model RS 35 Elite Series Steam Humidifier Integral Room Steam Blower Automatic Humidistat LCD user interface Drain tempering AHU Fan Relay Electrode Steam Generating Technology Model DS 15 Elite Series Steam Humidifier • • • • • • Requires duct mount or remote blower kit Automatic Humidistat LCD user interface Drain tempering AHU Fan Relay Electrode Steam Generating Technology *DS models require installation kit selection Model DS 35 Model DS35LC * Power Supply 120Vac 50/60Hz Steam Output 5.5 lbs/hr Gallons per Day 15.8 Dimensions 13 1/8 wide x 23 3/4 high x 8 1/4 deep Specifications Power Supply 230Vac 50/60Hz Steam Output 9-12 lbs/hr Gallons per Day 25-35 Dimesions 13 1/8 wide x 23 3/4 high x 8 1/4 deep Specifications Power Supply 120Vac 50/60Hz Steam Output 5.5 lbs/hr Gallons per Day 15.8 Dimensions 13 1/8 wide x 23 3/4 high x 8 1/4 deep Specifications Elite Series Steam Humidifier Power Supply 230Vac 50/60Hz • • • • • • Steam Output 9-12 lbs/hr Requires duct mount or remote blower kit Automatic Humidistat LCD user interface Drain tempering AHU Fan Relay Electrode Steam Generating Technology Gallons per Day 25-35 Elite Series Steam Humidifiers • • • • • • Specifications Dimensions 13 1/8 wide x 23 3/4 high x 8 1/4 deep *LC = (Low Conductivity Cylinder) Standard *DS models require installation kit selection Model DS 50 Model DS50LC * Specifications Elite Series Steam Humidifier Power Supply 230Vac 50/60Hz • • • • • • Steam Output 20 lbs/hr Requires duct mount or remote blower kit Digital ON / OFF Modulating Humidistat LCD user interface Drain tempering AHU Fan Relay Electrode Steam Generating Technology Gallons per Day 50-58 Dimensions 13 1/8 wide x 23 3/4 high x 8 1/4 deep *LC = (Low Conductivity Cylinder) Standard *DS models require installation kit selection 4 Elite Series Steam Humidifiers Model Selection Chart Integrated Mount Blower Capacity Adjustment Remote Enable & Alarm Relay LCD Graphic Display Continuity Sensor Foam Control Sensor Proportional 0 to 10V and ON-OFF Cylinder Hour Counter Auto Drain 3 Day Off AHU Fan Relay Yes Yes Yes Yes Yes Yes Yes Yes RS35 9-12 Room Steam lbs/hr Up to Yes 230V 25-35 6000 gpd Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes DS15 Duct Steam 120V 5.5 lbs/hr Up to Yes 15.84 3500 gpd Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 9-12 Yes Duct Steam lbs/hr Up to Yes 230V 25-35 6000 Low gpd Conductivity Yes Yes Yes Yes Yes Yes Yes Yes Yes 20 Yes Duct Steam lbs/hr Up to Yes 230V 50-58 10000 Low gpd Conductivity Yes Yes Yes Yes Yes Yes Yes Yes Yes GeneralAire Elite Steam GeneralAire Elite Steam GeneralAire Elite Steam DS35 DS35LC GeneralAire Elite Steam DS50 DS50LC Duct Mount Kit Remote Blower Kit Remote Blower Kit 230V Accessory DMNKIT Kit Option for DS35 Installation kit selection required for installation of DS models RMB35 230V Accessory Kit Option for DS35 Installation kit selection required for installation of DS models RMB15 120V Accessory Kit Option for DS15 Installation kit selection required for installation of DS models *DS models require kit selection for installation 5 Electrode Technology Yes Square Footage Covered Yes Capacity Yes GeneralAire Elite Steam Type Voltage RS15 5.5 Room Steam lbs/hr Up to Yes 120V 15.84 3500 gpd Model Replacement Steam Cylinder GeneralAire Elite Steam Humidifier Selection Guide NEPTRONIC NORTEC Res DLXE Yes Yes Yes Yes Yes Yes 35-14 CHF05V2 SKR25/30/40 Res DLXE 15-14 CH002V1 Res DLXE VT-2 Res DLXE VT-4 XT-10 NHTC020 XT-20 Yes SKR14 35-14 Yes 1150 CH005V2 SKR25/30/40 1160 CH009V2 35-15 Yes DRI-STEAM CAREL SKR14 APRILAIRE CHF02V1 Replacement Steam Generating Cylinder 15-14 Warranty Yes CodeValve GCV3412 Ball Valve Yes Grille Package Water Supply Tubing Kit Through Wall Blower Kit Saddle Valve Air Pressure Proving Switch Automatic Humidistat Yes Condensate Yes Steam Hose Yes Steam Nozzle Yes Auto Drain Tempering Fill Connector Brand Cross Reference 50-14 ON /OFF Yes Yes Yes Yes Modulating Humidstat Yes SK306 50-15 Yes 8ft 9ft Yes Yes Yes Yes Yes 12ft 13ft Yes Yes Yes Yes Yes Yes Yes Yes 12ft 13ft Yes Yes Yes Yes Yes Yes Yes Yes Yes 6 Elite Series Humidifiers We spend most of our days indoors. It is important to control the indoor relative humidity to maintain a comfortable and healthy indoor air environment. Very low humidity in your home in winter can result in dry, itchy skin or dry sinuses and nose. Dry skin can crack and peel and will look unattractive and can lead to infections. Dry noses and sinuses may lead to a clogging or swelling and closing of the air passages and cause breathing difficulty at night. Choosing a GeneralAire Humidifier will improve your comfort indoors and maintain a healthy environment so you can breathe a little easier. • A portion of the heated air from the furnace passes through a water-soaked pad where it absorbs additional moisture and then returns for distribution throughout your home. • Water is metered into the KineticFlo® Trough and dispersed uniformly across the pad. Unevaporated water drains from the bottom of the unit to eliminate mineral build-up. • DuraPlast® Automotive grade UV stable molded plastics. 7 Model 1000XM Elite Series Humidifier • The Select-Control Manual Humidistat give you the reliability you depend on for quality comfort control. Model 1000 Elite Series Humidifier • Automatic Humidistat features a manual or automatic mode with an outdoor sensor for temperature compensating control. Elite Series Humidifier • The Select-Control Manual Humidistat give you the reliability you depend on for quality comfort control. Model 900 Elite Series Humidifier • Automatic Humidistat features a manual or automatic mode with an outdoor sensor for temperature compensating control. Model 570XM Elite Series Humidifier • Select-Control Humidistat is included. Unit Size 16" wide x 16-1/2" high x 10" deep Plenum Opening 14" wide x 12" high Fan-powered unit mounts easily on the warm air plenum and delivers 18 GPD. Evaporator pad replacement number GA19 or GA 990-13. Model 1000XM Model 1000 Specifications Unit Size 12" wide x 16-1/2" high x 10" deep Plenum Opening 8-3/4" wide x 12" high Bypass Duct 6" diameter Bypass humidifier mounts easily on the warm or return plenum and delivers 17 GPD. Evaporator pad replacement number GA19 or 990-13. Model 900XM Model 900 Elite Series Humidifiers Model 900XM Specifications Specifications Unit Size 11-7/8" wide x 13-3/8" high x 9-1/2" deep • Bypass humidifier mounts easily on the warm or return plenum and delivers 12 GPD. Plenum Opening 8-3/4" wide x 9.5" high • Evaporator pad replacement number GA10. Bypass Duct 6" diameter Model 570 Elite Series Humidifier • Automatic Humidstat features a manual or automatic mode with an outdoor sensor for temperature compensating control. Model 570XM Model 570 8 Elite Series Humidifiers Model Selection Chart GeneralAire Elite Series Humidifier Selection Guide Model Type Gallons Square per Day @ Footage 120 Deg. Covered 24V Humidity Automatic Auto / Manual when M3 SelectHumidity Prevents Modes & System Control Controls Control Condensation Outdoor Fan Humidistat Dewpoint Outdoor on Windows Temperature Operates Temperature Display Compensation GeneralAire 570XM Flow Through 570XM 6” Bypass 12 Up to 2856 Yes Yes Flow Through 900XM 6” Bypass 17 Up to 3940 Yes Yes Flow Through 1000XM Fan Power 18 Up to 4214 Yes Yes 570 Flow Through 6” Bypass 12 Up to 2856 Yes Yes Yes Yes Yes 900 Flow Through 6” Bypass 17 Up to 3940 Yes Yes Yes Yes Yes Flow Through 1000 Fan Power 18 Up to 4214 Yes Yes Yes Yes Yes GeneralAire 900XM GeneralAire 1000XM GeneralAire 570 GeneralAire 900 GeneralAire 1000 9 TRION Replacement Vapor Pad® SKUTTLE Warranty Stainless CodeValve DuraPlast® Steel GCV3412 UV Stable Solenoid Ball Valve Pad Frame Valve Seat HONEYWELL Integrated Bypass Damper APRILAIRE Brand Capacity Cross Reference LEGACY Optional Outdoor Sensor Included KineticFlo® Distribution Trough for Even Water Distribution Across Vapor Pad® 220A 550 225A 2000 G200 500M 225H Yes Yes Yes No Yes GA10 Yes Yes Yes No Yes GA19 or 990-13 260A SL16 600M 265A 2001 G300 1042 560 265H Yes No Yes No Yes GA19 or 990-13 1137 Yes Yes Yes Yes Yes Yes GA10 Yes Yes Yes Yes Yes Yes GA19 or 990-13 1099 Yes Yes No Yes Yes Yes GA19 or 990-13 360B 1137 700A 365B 2002 G100 365DG 360A 700M 365A 2002 G100 760 365H 220B 500A 225B 225DG 360B 365B 365DG 10 11 <#> Legacy Series Humidifiers We spend most of our days indoors. It is important to control the indoor relative humidity to maintain a comfortable and healthy indoor air environment. Very low humidity in your home in winter can result in dry, itchy skin or dry sinuses and nose. Dry skin can crack and peel and will look unattractive and can lead to infections. Dry noses and sinuses may lead to a clogging or swelling and closing of the air passages and cause breathing difficulty at night. Choosing a GeneralAire Humidifier will improve your comfort indoors and maintain a healthy environment so you can breathe a little easier. • A portion of the heated air from the furnace passes through a water-soaked pad where it absorbs additional moisture and then returns for distribution throughout your home. • Water is metered into the KineticFlo® Trough and dispersed uniformly across the pad. Unevaporated water drains from the bottom of the unit to eliminate mineral build-up. Model 1137 Legacy Series Humidifier Specifications • M3 Select-Control Manual Humidistat is included. Unit Size 16" wide x 14" high x 10" deep • Fan-powered unit mounts easily on the warm air plenum and delivers 21.3 GPD. • Evaporator pad replacement number 990-13. Model 1099 LHS • M3 Select-Control Manual Humidistat is included. • GeneralAire's highest capacity model delivers 23 GPD and is ideal for today’s larger homes. • Replacement evaporator pad number 1099-20. Models 1042 LH Specifications Unit Size 16" wide x 16" high x 11" deep Plenum Opening 13-1/4" wide x 9-1/4" high Bypass Duct 7" diameter (collar supplied) Legacy Series Humidifier Specifications • Model 1042 LH includes the M3 Select-Control Manual Humidistat. Unit Size 15" wide x 11-1/2" high x 9" deep • Model 1042 DME includes the E2 Digital Automatic Humidistat. Plenum Opening 10-1/4" wide x 9-1/2" high • A highly efficient flow-through unit that delivers 19.2 GPD. Bypass Duct 6" diameter (collar supplied) Legacy Series Humidifiers Legacy Series Humidifier Plenum Opening 15" wide x 9-1/2" high • Replacement evaporator pad number 990-13. Models SL16 Legacy Series Humidifier • M3 Select-Control Manual Humidistat is included. • Replacement evaporator pad number 990-13. • It fits as small as 8.5" ducts and delivers 19.2 gallons of water per day. Specifications Unit Size 12" wide x 16-1/2" high x 9-3/4" deep Plenum Opening 7-1/2" wide x 8-1/4" high Bypass Duct 6" diameter left or right 12 Legacy Series Humidifiers Model Selection Chart GeneralAire Legacy Humidifier Selection Guide Model M3 KineticFlo® SelectDistribution Humidity Control HuTrough Stainless Gallons Square when Integrated 16-21 Flush midistat for Steel Type per Day @ Footage System Bypass Warranty Duct Mount with Even Water Solenoid 140 Deg. Covered Fan Damper Humidistat Comfort Distribution Valve Seat Operates Range Across Gradient Vapor Pad® GeneralAire SL16 Flow Through 6” Bypass 19 Up to 2856 Flow 1042LH Through 6” Bypass 19 Up to 3940 Flow Through 1099LHS 7” Bypass 23 Flow Through Fan Power 21 SL16 Yes Yes Yes Yes Yes Yes Yes Up to 4596 Yes Yes Yes Yes Up to 4214 Yes Yes Yes Yes GeneralAire 1042 LH GeneralAire 1099 LHS GeneralAire 1137 1137 13 Yes Solenoid Tap Valve Yes Yes 24V Yes Yes Yes Yes 24V Yes Yes Yes Yes 1099-20 950 120V Yes Yes Yes Yes 990-13 1000 APRILAIRE HONEYWELL 900 600M 260A 265A 265H 2001 G300 S1-HU17MB 900 600M 260A 265A 265H 2001 G300 S1-HU17MB 700M 360A 365A 365H 2002 G100 S1-HU18MP SOURCE-1 TRION SKUTTLE ELITE Replacement Vapor Pad® Narrow Duct Adapter Plate Damper Assembly Plenum Ring 24 ft Bypass Duct Transformer 10 ft Water Sply Tube 15 ft 5/8" Drain Hose 10 ft 24V Thermostat Wire Voltage 24V Yes Brand Capacity Cross Reference 14 15 <#> Legacy Series Drum Humidifiers We spend most of our days indoors. It is important to control the indoor relative humidity to maintain a comfortable and healthy indoor air environment. Very low humidity in your home in winter can result in dry, itchy skin or dry sinuses and nose. Dry skin can crack and peel and will look unattractive and can lead to infections. Dry noses and sinuses may lead to a clogging or swelling and closing of the air passages and cause breathing difficulty at night. Choosing a GeneralAire Humidifier will improve your comfort indoors and maintain a healthy environment so you can breathe a little easier. Model 81 Specifications Legacy Series Drum Humidifier Unit Size 12" wide x 11-1/2" high x 11" deep • M3 Select-Control Manual Humidistat is included. Plenum Opening 8" wide x 7-1/2" high • High-capacity model delivers 18 GPD. Bypass Duct 6" diameter (bypass pipe assembly supplied) Model 65 Specifications Legacy Series Drum Humidifier Unit Size 10" wide x 9" high x 9-1/2" deep • M3 Select-Control Manual Humidistat is included. Plenum Opening 7-3/4" wide x 5-3/4" high • An ideal humidifier that delivers 13.3 GPD. • Replacement evaporator sleeve part number 65-5. Bypass Duct 5" diameter (bypass pipe assembly supplied) Model 747 L Legacy Series Drum Humidifier • A compact unit that mounts in the warm air supply duct when bypass or flow through installations aren’t possible. This unit delivers 16.0 GPD. • Equipped with a built-in humidity control. Specifications Unit Size 12" wide x 16" high x 4" deep Plenum Opening 10-1/2" wide x 15-1/8" high • Replacement evaporator sleeve part number 727-12. Model 800 Legacy Series Drum Humidifier • All forced warm air heating system. • Evaporator pad replacement number 880 plates. Legacy Series Drum Humidifiers • Split drum design allows easy removal of evaporator sleeve part number 81-15. Specifications Unit Size 9" wide x 6-3/4" high x 7-1/2" long Bypass Duct N/A 16 Legacy Series Drum Humidifiers Model Selection Chart GeneralAire Legacy Drum Humidifier Selection Guide Gallons Square per Day @ Footage 140 Deg. Covered M3 SelectControl Humidistat with Comfort Range Gradient 747-26 Temp. Actuated Humidity Control & Plug-In Transformer Humidity when System Fan Operates Model Type 81 Float Reservoir Drum 18 Up to 4571 Yes Yes 65 Float Reservoir Drum 13 Up to 3333 Yes Yes 747L Under-Duct Drum 16 Up to 3809 800 Plate Type Up to 4.2 Up to 1000 GeneralAire 81 GeneralAire 65 GeneralAire 747L GeneralAire 800 17 Yes 24V Yes Yes Yes Yes 5" 120V Yes Yes Yes Yes Yes 6" 6" Yes 81-15 5" Yes Yes AUTO FLOW 6" SKUTTLE Yes Yes HONEYWELL 24 ft Bypass Duct Yes Float Valve Transformer Yes Damper Assembly 10 ft 24V Thermostat Wire 24V Plenum Ring Saddle Tap Valve 10 ft Water Sply Tube Voltage Warranty Brand Capacity Cross Reference HE120A 90 97 65-5 45 800BP 200P 727-12 86UD Replacement Vapor Pad® 880 18 19 <#> General Series UV Air Purifiers The air we breathe in our homes can be up to 100 times more polluted than outdoor air, according to the Environmental Protection Agency. So let GeneralAire provide you with healthier indoor air and “Let the Sunshine In!” with GeneralAire UV Air Purifiers. GeneralAire’s Ultraviolet (UV) light technology enables you to have whole-house air treatment energy, like the sun, to improve your homes indoor air quality. Battle microorganisms with highly intensive ultraviolet “C” (UVC) germicidal irradiation. This air treatment is designed to be more effective at significantly reducing unwanted bioaerosols (germs) in your home. Forget about the rest, and decide on the best indoor air quality air purification system. You can count on GeneralAire ultraviolet air treatment products to out last and out perform the other brands. • QuartzCoat® Lamp Life Extension Coating (18,000) Hours) 2 year lamp replacement • Power Cord Disconnect (Appliance Coupler Design) • Max 2000 CFM or 4500 SQ ft • 5 Year Ballast Warranty Model GUV25403A General Series UV Air Purifier Specifications • 36 watt, 16 inch Germicidal H-Lamp UVV16HC 4" x 11.75" x 2.75" (W x H x D) • 180 µW/cm²@1 meter UVC Lamp Intensity Rating • 8 watt, 5 inch Super Plasma Lamp UVV5CL Max 2000 CFM or 4500 SQ ft • 12 µW/cm²@1 meter UVV Lamp Intensity Rating • 120 VAC / 240VAC Regulating Electronic Ballast • 18,000 hours lamp life efficiency General Series UV Air Purifier Specifications • 36 watt, 16" UVC Germicidal H-lamp UVV16HC 4" x 8.75" x 2.75" (W x H x D) • 180 µW/cm²@1 meter UVC Lamp Intensity Rating • 120 VAC / 240 VAC Regulating Electronic Ballast General Series UV Air Purifiers Model GUV100A83 Max 2000 CFM or 4500 SQ ft • 18,000 hours lamp life efficiency Model PCO2450 General Series UV Air Purifier Specifications • 50 Watt 18 inch UVC Lamp 8-1/2" x 7-3/8" x 2" (W x H x D) • 135 µw/cm²@ 1 meter UVC Lamp Intensity Rating • High Output Temperature Compensating (HOTC) 120v / 240v Ballast Max 2000 CFM or 4000 SQFT • 24 SQ ft, 3500 SQ inch Titanium Dioxide TiO2 Anatase Semi-conductor • 18,000 hours lamp life efficiency Model MS24 MicrobeSwatter® UV Air Purifier • Germicidal Only • 36 Watt 16 inch UVC H-Lamp Model MS24OZ Specifications Max 2000 CFM or 4000 SQ ft 105 µW/cm²@1 meter UVC Lamp Intensity Rating MicrobeSwatter® 24 VAC Regulating Electronic Ballast MicrobeSwatter® SweetShot Requires 50VA transformer (GA3501) *Not Included • 36 watt 16 inch UVC H-Lamp with 4 inch fused single tube O3 broad spectrum quartz SweetShot 9,000 hours lamp life efficiency MicrobeSwatter® SweetShot GA3501 *Not Included AG2436 24V Ballast 20 General Series UV Air Purifiers Model Selection Chart Lamp Intensity Output Measured as mw/cm2 @1 meter 180 16 inch UVC H-Lamp 36 watts 180 5 inch UVV 8 watts 12 18 inch UVC 50 watts 135 Photocatalytic Oxidation Process with 3500 SQ IN 24 SQ ft Anatase TiO2 VectorFlo® Semi-conductor Lamp Length and Wattage Output Yes 16 inch UVC H-Lamp 36 watts Super Plasma Broad Spectrum Quartz Lamp with Oxy Regulator Lamp Indicator Appliance Coupler Disconnect High Output Intensity Rating Electronic Regulating Ballast Target Disinfection Air Treatment Irradiation Model GeneralAire Ultraviolet Air Purifier Selection Guide GUV100A83 GUV100A83 Yes Yes Yes Yes Yes GUV25403A GUV25403A Yes Yes Yes Yes Yes Yes Yes PCO2450 PCO2450 Yes Yes Yes Yes Yes Yes MS24 MS24 Yes MS24OZ MS24OZ 21 Yes Yes 50 VA GA3501 Yes Transformer Required (Not Included) 16 inch UVC Lamp 36 watts Yes 105 16 inch UVC Fused 36 watt O3 lamp Yes 120V or 240V 18,000 hours 2000 CFM 2 year Lamp or Efficiency 4500 SQFT 120V or 240V 18,000 hours 2000 CFM 2 year Lamp or Efficiency 4500 SQFT S1-UV50120 120V or 240V 18,000 hours 2000 CFM 2 year Lamp or Efficiency 4000 SQFT S1-UV50120 UV100RMI Blue-TubeUV Field Controls Model T r i ato m i c M o d e l UV100A1059 Triad S1-UV36120 UV100A2008 FreshAire UV Flex-Mount UV100E3007 Lightstick S1-UV22024 24V Honeywell Model Source 1 Model DustFree Model Warranty Application Range QuartzCoat® Extend Lamp Life Coating Voltage Brand Cross Reference UV-12 UV-18 UV-28 UV-16R24V 9,000 hours 2000 CFM 1 year Lamp or Efficiency 4000 SQFT Odor Spice Odor Spice 22 23 <#> Energy/Heat Recovery Ventilators Whole House Dehumidifier Improve indoor air quality by efficiently introducing fresh outside air into the home while discharging stale indoor air outdoors. The GeneralAire HRV / ERV product line offers many desirable features that the competition does not. The patented DualTrol® control eliminates the need for fixed damper balancing of the system. The DualTrol® varies the speed of the intake and discharge motors for the precise balancing consistently. Models 3160 & 3220 Energy Recovery Ventilators Specifications • 2 operating modes (Intermittent and Continuous Ventilation) Unit Size 3160: 23-7/8" x 21-1/2" x 11-3/8" 3220: 23-7/8" x 21-1/2" x 16-1/2" • Variable speed • Proportional defrost (Patent Pending) • ISF™ 6” (dia.) collar system • 10-year limited warranty on ventilation motors • 5-year limited warranty on the energy recovery core • 5-year limited warranty on all other components CFM 3160: 30 to 160 3220: 50 to 220 Heat Recovery Ventilators Specifications • 2 operating modes (Intermittent and Continuous Ventilation) Unit Size 8160: 23-7/8" x 21-1/2" x 11-3/8" 8220: 23-7/8" x 21-1/2" x 16-1/2" • Variable speed • Proportional defrost (Patent Pending) • ISF™ 6” (dia.) collar system • 10-year limited warranty* on ventilation motors • 5-year limited warranty on the energy recovery core • 5-year limited warranty on all other components Dehumidifier 1300 Heat exchanger (L x H x W) 8160: 12" x 12" x 10" 8220: 12" x 12" x 15" CFM 8160: 30 to 160 8220: 50 to 220 Whole House Specifications • Optional wall-mounted control Dimensions 19.15"H x 25.13"W x 30" L • Cleanable filter • Frost control • Minimal maintenance • Quiet operation • Energy efficient • Fits any size home ERV/HRV and Dehumidifiers Models 8160 & 8220 Heat exchanger (L x H x W) 3160: 12" x 12" x 10" 3220: 12" x 12" x 15" Weight 150 lbs Duct Connections 8" diameter (inlet & outlet) Capacity 130 pints/day 24 HRV/ERV & Whole House Dehumidifier Model Selection Chart GeneralAire Energy and Heat Recovery Ventilator Selection Guide Net Moisture Defrost Airflow @ Transfer Control .20 in. wg Sensible Variable Recovery Speed Insulated Efficiency Balancing Cabinet HV I Certified Fan Motors (2) Model Heat Transfer 3160 Yes Yes Yes 163 74% Yes Yes 3220 Yes Yes Yes 195 72% Yes Yes 8160 Yes NA Yes 163 78% Yes Yes 8220 Yes NA Yes 195 74% Yes Yes GeneralAire Whole-House Dehumidifier Selection Chart 25 Model Capacity 1300 130 pints Airflow @ Power .60 in. w.c. Supply 400 CFM 115V-1 9.5 RLA Filter Weight Washable Nylon Mesh 150lbs Adjustable R-4.5 Intregal Cabinet Dehumidistat Insulation Yes 1 Expanded Polymeric Material VENAMR BROAN HONEYWELL SOURCE 1 APRILAIRE Brand Cross Reference AVS Duo 1.4 ERV100HC 8100 S1-ERV220 ER200B2006 AVS Duo 1.9 ERV200HC Yes NA AVS S1-HRV160 HR150B1005 Constucto 1.5 AVS Solo 1.5 HRV100H Yes NA AVS S1-HRV220 HR200B1005 Constucto 2.0 AVS Solo 2.0 HRV200H DualTrol® Warranty Yes NA Yes Thermostatic Expansion Warranty valve Yes S1-ERV160 ER1502006 Brand Cross Reference Aprilaire Model Source 1 Model Honeywell Model ThermaStor UltraAire Model HealthyAIr Model 1700 1720 S1-DEHU130 DH90 UA-90H UA-135H DVA150NC DVA400H 26 27 <#> Importance of Air Filtration While it’s easy to focus on visible pollutants…smokestacks, vehicle exhaust and the outdoors, the air inside your home can be even more hazardous to your health. In fact, indoor air can be up to 100 times more polluted than the air we breathe outdoors. Studies show, that most people spend as much as 90% of their time indoors. AC500 HEPA Air Cleaner • Dimension (D x W x H): 13" x 17" x 22" 30% Pleated Prefilter Replacement: 12" x 16" x 2" Charcoal Replacement Filter: 12" x 16" x 3/8" H.E.P.A. Replacement Filter: 12" x 16" x 2.5" • Performance: 200/300CFM • Voltage: 120 VAC @ 60 Hz • Amperage: 1.5A • Power Consumption : 130W • Certification: c CSA us • Efficiency: 99.97 @ .30 microns GA52F32 Grille Mount Electronic Air Cleaner GA50 Series Electronic Air Cleaners • Up to 99.7% efficient at 0.30 mircrons • Carbon filters that remove gaseous odors • Dual Indicator Lights show unit operation at a glance Maintenance Clean collecting cell every 3 months with: DAX EAC Cell Detergent Non-Caustic / Non Acid • Electronic Air Proving Switch cycles Air Cleaner On/Off with system fan AC22 and AC24 Replacement Media • MERV 11 Micro Fiber AC22: 12758 • No-tear design AC24: 401-13156 • Strong expandable media • 75% dust spot efficiency 1.0 to 3.0 microns MAC Series 2000, 2020, 1400, 1200 Replacement Media • MERV 10 Opti-Fiber Media *MAC1200 MERV 8 MAC 2000: 5FM2025 • Opti-Fiber Media with low pressure drop characteristics. • 61.8% minimum average efficiency 1.0 to 3.0 microns MAC-L MAC 2020: 5FM2020 MAC 1400: 5FM1625 MAC 1200: 3FM1625 Right Angle Air Cleaner Replacement Media • MERV 10 Opti-Fiber Media MAC-L: 5FM2025 High Efficiency Media Air Cleaners AC Series • Opti-Fiber Media with low pressure drop characteristics. • 61.8% minimum average efficiency 1.0 to 3.0 microns 28 AC500 HEPA/Media Air Cleaners Model Selection Chart GeneralAire Air Cleaner Selection Guide Model Type Unit HxDxW Size (in inches) AC500 AC500 GA50A20, GA50A14 GA50A22 H.E.P.A. 120V 22" x 13" x 17" Rated Application Airflow CFM Bypass Duct Mount or Remote Mount 300 Arrestance Efficiency at 492 FPM Dust Spot Efficiency at 492 FPM 99.97% at .30 microns NA NA up to 99% at .30 microns NA 99% at 600 CFM NA 96% at 600 CFM 20" x 25" x 7.5" 2000 16" x 25" x 7.5" 1400 20" x 20" x 7.5" 1400 24" x 7" x 32" 2000 up to 96% at .30 microns Inline 2000 11 97% 75% 1.0 to 3.0 microns 1.0 to 3.0 microns 16" x 25" x 7" Inline 1400 20" x 20" x 7" Inline 1400 10 75% 1.0 to 3.0 microns 61.8% 1.0 to 3.0 microns 20" x 25" x 7" Inline 2000 MAC-L Right Angle AIr Cleaner 23-7/16" H 25-5/8" D 15-5/16" W Inline Adj. Drop Dim. 24 x 8 24 x 10 2000 10 75% 1.0 to 3.0 microns 61.8% 1.0 to 3.0 microns MAC1200 Cartridge Media 16" x 25" x 5" Inline 1200 8 75% 1.0 to 3.0 microns 53.4% 1.0 to 3.0 microns GA50A20 GA50A14 Electronic Air Cleaner GA50A22 GA52F32 GA52F32 AC22 / AC24 MERV Rating Grille Mount AC22 AC24 20" x 25" x 10" Expandable Media MAC1400, MAC2020 MAC1400 MAC2000 MAC1400XM MAC2020 MAC2020XM Cartridge Media MAC2000 MAC2000XM 16" x 28" x 10" MAC-L MAC1200 29 30 % Pleated Prefilter Charcoal Filter Every Six Months 12" x 16" x 2" 12" x 16" x 3/8" HMK500 Annual Kit H.E.P.A. Every Two Years 12" x 16" x 2.5" HF500 HEPA Filter G99 Airflow Warranty Indicator Gage NA Optional Trion Air Bear Model Filter Media Dimensions Nominal (Actual) (H x W x D) Honeywell Model NA Maintenance Cycle Source 1 Model Initial Pressure Drop Aprilaire Model Brand Cross Reference NA S1-HEPA300 F500A1000 NA S1-EAC20002025 F300A2025 S1-EAC14001625 F300A1625 S1-EAC14002020 F300A2020 .157 w/o carbon .157 w/o carbon .157 w/o carbon .294 Clean collecting cell 3 months with DAX NA Clean collecting cell 3 months with DAX NA NA NA 20" x 25" x 6" 12758 .18 in. w.c. Every 12 Months .22 in. w.c. 16" x 27" x 6" 401-13156 Every 6 months 20 x 20 x 5 (20" x 20-1/4" x 4-15/16") 5FM2020 2200 S1-MAC11202506 2400 S1-MAC11162506 2120 Intregal 16 x 25 x 5 (16" x 24-1/4" x 4-15/16") 5FM1625 .23 in. w.c. S1-EAC2000GM Optional 20 x 25 x 5 (20" x 24-1/4" x 4-15/16") 5FM2025 2140 TGM 2000 NA NA S1-MAC10162505 F100F1012 F100F2002 Air Bear 455602-119 S1-MAC10202005 F100F1020 F100F2036 Air Bear 455604-019 S1-MAC10202505 F100F1038 F100F2010 Air Bear 455602-019 459200-005 .26 in. w.c. Every 6 months 20 x 25 x 5 (20" x 24-1/4" x 4-15/16") 5FM2025 Optional Air Bear 447380-002 459202-001 .23 in. w.c. Every 6 Months 16 x 25 x 3 (16" x 24-1/4" x 2-15/16") 3FM1625 Optional Air Bear Cub 425599-008 30 31 <#> Replacement Filters Replacement Filter Media 4050 201-12880 MERV 11 Expandable Strung 4051 401-13156 MERV 11 Expandable Media Media for AprilAire 2200. Standard Package: 9 for 2400, AC24. Standard Package: 9 Replacement Filter Media 4001 12758 Micro Fiber MERV 11 Expandable Media for AC1, AC22. Standard Package: 9 4401 13415 Micro Fiber MERV 11 Expandable Media for AC4. Standard Package: 6 FlatPac Replacement Filter Media 4526 FP2025X5 20 x 25 MERV 8 Media. Replaces GeneralAire part #5FM2025. Replaces Trion part #255649-102. 4527 FP1625X5 16 x 25 MERV 8 Media. (Actual Dimension 20-1/8" x 25-3/16" x 4-15/16") Replaces GeneralAire part #5FM1625. Replaces Trion part #255649-105. 4528 FP2020X5 20 x 20 MERV 8 Media. Replaces GeneralAire part #5FM2020. Replaces Trion part #255649-103. (Actual Dimension 16-1/8" x 25-3/16" x 4-15/16") (Actual Dimension 20-1/8" x 20-5/8" x 4-15/16") HEPA Replacement Components 4650 4620 4610 HCM500 Collar Mount Adaptor Kit for AC500 HF500 Replacement HEPA Filter for AC500 HMK500 Annual Filter Replacement Kit (2) Pre-filters/(2) Charcoal 4361 FP1620HW 16 x 20 MERV 8 Media. Replaces Honeywell part #FC100A1003. (Actual Dimension 15-13/16" x 19-5/8" x 4-3/8") 4362 FP1625HW 16 x 25 MERV 8 Media. Replaces Honeywell part #FC100A1029. (Actual Dimension 15-13/16" x 24-13/16" x 4-3/8") 4363 FP2020HW 20 x 20 MERV 8 Media. Replaces Honeywell part #FC100A1011. (Actual Dimension 19-13/16" x 19-5/8" x 4-3/8") 4364 Standard Package: 12 FP2025HW 20 x 25 MERV 8 Media. Replaces Honeywell part #FC100A1037. (Actual Dimension 19-13/16" x 24-13/16" x 4-3/8") GeneralAire MAC Series Replacement Filter Media 4501 5FM2025 MERV10 20 x 25 x 5 Media for MAC2000 and MAC-L. Also fits TRION AirBear Supreme 2000, replaces TRION media part #255649-102. (Actual Dimension 20" x 24-1/4" x 4-15/16") 4511 5FM1625 MERV 10 16 x 25 x 5 Media for MAC1400. Also fits TRION AirBear Supreme 1400, replaces TRION media part #255649-105. (Actual Dimension 16" x 24-1/4" x 4-15/16") 4531 5FM2020 MERV 10 20 x 20 x 5 Media for MAC2020. Also fits TRION AirBear Supreme 20 x 20, replaces TRION media part#255649-103. (Actual Dimension 20" x 20-1/4" x 4-15/16") Standard Package: 6 Honeywell Series Replacement Filter Media GA100A03 16 x 20 MERV 10 Media. Replaces Honeywell part #FC100A1003. (Actual Dimension 15-13/16" x 19-5/8" x 4-3/8") 4352 GA100A29 16 x 25 MERV 10 Media. Replaces Honeywell part #FC100A1029. (Actual Dimension 15-13/16" x 24-13/16" x 4-3/8") 4354 GA100A11 20 x 20 MERV 10 Media. Replaces Honeywell part #FC100A1011. (Actual Dimension 19-13/16" x 19-5/8" x 4-3/8") 4356 GA100A37 20 x 25 MERV 10 Media. Replaces Honeywell part #FC100A1037. (Actual Dimension 19-13/16" x 24-13/16" x 4-3/8") Standard Package: 5 GeneralAire AC MERV 8 Replacement Filters 4350 Media Option 4122 GA102 20 x 25-1/8 x 3-3/4 MERV 8 Cartridge Media for AC22. Also fits Aprilaire model 2120. 4123 GA104 15-5/8 x 27-5/8 x 3-3/4 MERV 8 Cartridge Media for AC24. Also fits Aprilaire model 2140. Standard Package: 6 MAC1200 Replacement Filter Media 4521 3FM1625 MERV 8 16 x 25 x 3 Media for MAC1200. (Actual Dimension 16" x 24-1/4" x 2-15/16") Also fits TRION AirBear Cub. Replaces TRION media part #255649-101. Standard Package: 6 32 Accessories Automatic Humidistat 7025 E1 Automatic Humidistat Operate in Manual or Automatic Modes Wall or Duct Mount Select-Control Humidistat 7015 M3 Select Control Humidistat Operates in Manual Mode Wall or Duct Mount Contemporary Design for Living Space Mounting Indoor Humidity/Temp. Gage 7024 G98 Indoor Humidity/Temp. Gage Digital Humidity Display Digital Temperature Display Wall Mounted or Table Top Positioning Air Filter Gage 4002 G99 Air Filter Gage: Since the cleanliness of all homes are not equal, GeneralAire offers an easy-to use, easy-to-read gage. The air filter media will load, capturing airborne particulates, raising the gage indicator to the red-zone, letting you know it’s time to change your filter. EAC Cell Detergent 33 4746 9900 DAX EAC Cell Detergent 32oz. Non-Caustic / Non Acid The assurance for high performance efficiency output! Humidifier Evaporator Pads 7002 990-13 Replacement pad for GeneralAire Legacy humidifier models 709, 990, 1040, 1042, 1137 and SL16 Also fits GeneralAire Elite model 900 and 1000 7047 1099-20 Replacement pad for GeneralAire Legacy humidifier model 1099 Also fits GeneralAire Elite model 950 Humidifier VaporPad® 7919 7923 GA19-Replacement pad for Elite Humidifier 900 & 1000 GA23-Replacement pad for Elite Humidifier 950 Humidifier VaporPad® 7900 GA10 for GeneralAire model 570 Fits AprilAire models 110, 220, 558, 550 and 500 Fits Honeywell models HE220 and HE225 7901 7902 GA12 fits AprilAire models 224, 112, 440, 445A and 445 GA35 fits AprilAire models 350, 360, 568, 560, 600, 768, 760 and 700 Code Valve 7016 Accessories GCV3412 is a 1/2" and 3/4" all in one universal sweat connection 1/4 turn water supply ball valve. A 1/4" compression fitting accepts 1/4" copper tubing to supply water to the humidifier. Valuable where plumbing codes require this feature. Standard with all Elite Automatic Humidifier Models. Solenoid Valve 7221 GA4040 24V with stainless steel seat For GeneralAire Elite flow-through humidifiers Fits AprilAire model humidifiers Fits Honeywell model humidifiers 24V Current Sensing Relay 7026 GA50 24 volt Current Sensing Relay, makes blower control isolation easy, great for humidifiers 7027 GA51 120 volt Current Sensing Relay, makes blower control isolation easy, great for electronic air cleaners and small load rated fans 34 Accessories Orifices: Yellow, Orange, Blue, White & Red 7580 7581 7587 7589 7590 GA4231 Yellow Orifice for 570, 900, 1000, 550, 500, 600 GA4299 Orange Orifice for 950 GA4232 Blue Orifice for 350, 360 GA4007 White Orifice for 110, 220 GA4021 Red Orifice for 112, 224 12 unit increments accepted only Strainer 7564 GA4040 for models 570, 900, 1000, 1099LHS Also fits Aprilaire and Honeywell models Fan Blade 7564 GA4247 for models 1000, 760, 700, and HE365 Motor 7584 GA4237 for models 1000, 760, 700 and HE365 Relay Circuit Board 7586 35 GA4238 for models 1000, 1137, 700 and HE365 Pressure Proving Switch 7021 12500 Air Pressure Proving Switch Range: 0.5" W.C. Solenoid Valves 7014 7052 7341 990-53 Solenoid Valve 24V for model 1042, 1137 1099-42 Solenoid Valve 24V for model 1099L/LH/R 1137-17 Solenoid Valve 115V for model 1137 4305 GA3501 120 / 208 / 230 Primary to 24V Secondary Multi-Mount: Foot Mount, Plate Mount, Spud Mount Recommended for MicrobeSwatter® 24v UV Air Purifier Accessories 50 VA Transformer Solenoid Valve 7604 16-20 Solenoid Valve 24V for SL16 Fan Motor and Fan Blade Assembly 7337 7350 1137-8 Fan Motor for 1137 1137-50 Fan Blade Assembly for 1137 36 Minimum Efficiency Reporting Value (MERV) An "overall" reporting value of a 52.2-evaluated air filter is the expression of the Minimum Efficiency Reporting Value (MERV). The MERV is a single number that is used, along with the air velocity at which the test was performed; to simplify the extensive data generated by the method of testing. MERV is expressed on a 16 point scale and is derived from the Particle Size Efficiency (PSE) for each of the three groups. (See Table 2: MERV Parameters.) The average PSE for each of the three groups (E1, E2, and E3) is referenced against the Minimum Efficiency Reporting Value Parameters (see Table 2: MERV Parameters.) Move up the appropriate Range Group (E1, E2, and E3) on Table 2 and record the MERV to the left of the first true statement. Do this for all three groups. Standard Test Airflow Rates The Minimum Efficiency Reporting Value (MERV) must be stated with the air velocity at which the filter was tested. For example, if the filter was tested with an air velocity of 492 FPM and was found to be MERV 10, the filter's Minimum Efficiency Reporting Value would be MERV 10 @ 492 FPM. ASHRAE Standard 52.2 tests are to be conducted at one of seven airflow rates: 118 FPM (0.60 m/s) 246 FPM (1.25 m/s) 295 FPM (1.50 m/s) 374 FPM (1.90 m/s) 492 FPM (2.50 m/s) Table 1: ASHRAE 52.2 Particle Size Ranges Range Size 1 0.30 to 0.40 Group 2 0.40 to 0.55 3 0.55 to 0.70 4 0.70 to 1.00 630 FPM (3.20 m/s) 5 1.00 to 1.30 748 FPM (3.80 m/s) 6 1.30 to 1.60 test airflow rate, or the values in Table 2, whichever is greater. 7 1.60 to 2.20 Average Arrestance By Standard 52.1 8 2.20 to 3.00 9 3.00 to 4.00 10 4.00 to 5.50 11 5.50 to 7.00 12 7.00 to 10.00 Minimum Final Resistance Final resistance must be at least twice the initial resistance at the Filters with an efficiency of less than 20% in E3 (MERV 1 through MERV 4) must be tested per the arrestance test of ASHRAE Standard 52.1 E1 E2 E3 Table 3: MERV Parameters Standard 52.2 Minimum Efficiency Reporting Value (MERV) A37 Composite Average Particle Size Efficiency, % in Size Range, µm Range 1 (0.3-1.0) Range 2 (1.0-3.0) Range 3 (3.0-10.0) Average ASHRAE Arrestance, % by Standard 52.1 Method 1 n/a n/a E3 < 20 2 n/a n/a 3 n/a 4 Minimum Final Resistance PA Inches of Water Aavg < 65 75 .3 E3 < 20 65 < Aavg < 70 75 .3 n/a E3 < 20 70 < Aavg < 75 75 .3 n/a n/a E3 < 20 75 < Aavg 75 .3 5 n/a n/a 20 ≤ E3 < 35 n/a 150 .6 6 n/a n/a 35 ≤ E3 < 50 n/a 150 .6 7 n/a n/a 50 ≤ E3 < 70 n/a 150 .6 8 n/a n/a 70 ≤ E3 n/a 150 .6 9 n/a E2 < 50 85 ≤ E3 n/a 250 1.0 10 n/a 50 ≤ E2 < 65 85 ≤ E3 n/a 250 1.0 11 n/a 65 ≤ E2 < 80 85 ≤ E3 n/a 250 1.0 12 n/a 80 ≤ E2 90 ≤ E3 n/a 250 1.0 13 E1 ≤ 75 90 ≤ E2 90 ≤ E3 n/a 350 1.4 14 75 ≤ E1 < 85 90 ≤ E2 90 ≤ E3 n/a 350 1.4 15 85 ≤ E1 < 95 90 ≤ E2 90 ≤ E3 n/a 350 1.4 16 95 ≤ E1 95 ≤ E2 95 ≤ E3 n/a 350 1.4 *Information provided from the National Air Filtration Association UV Potency Required for Microbe Disinfection (measured as microWatt seconds per centimeter squared µW-sec/cm²) Bacteria UV Dose Bacillus Paratyphosus 6,100 Legionnella Bozemanii 3,500 Legionnella Micdadei 3,100 Mycobacterium Tuberculosis 10,000 Salmonella Enteritidis 7,600 Salmonella Typhi (Typhoid Fever) 7,000 Streptococcus Hemolyticus 5,500 Virus UV Dose Influenza 6,600 Infectious Hepatitis 8,000 Adeno Virus Type 3 4,500 24,000 Mold UV Dose Aspergillus Amstelodami 77,000 Mucor Mucedo 77,000 Penicillium Chrysogenum 56,000 Yeast UV Dose Baker's Yeast 8,000 Brewer's Yeast 13,200 Information Rotavirus This chart is intended to illustrate the potential effectiveness of ultraviolet wavelength exposure to various bacteria microbes and is based on credible university and independent laboratory studies. General Filters, Inc. does not make any claims to accuracy of information. Ultraviolet wavelength potency is measured at one meter from the lamp. An accepted standard measurement by lamp manufacturers. Calculate ultraviolet radiation potency at measured distances by multiplying the potency of the lamp (µW/cm² @ 1 meter) by the potency factor. Example: Multiply the GUV100A83 potency output of (180 µW/cm² @ 1 meter) by the distance of 2 inches (69 Potency Factor) = 12,420 µW-sec/cm². Distance from Lamp Potency Factor Distance from Lamp Potency Factor 0 354 12 12 1 127 15 6 2 69 20 4 4 32 25 3 6 20 30 2 8 14 35 1.4 10 13 39.97 1 Voltage Lamp Output in Watts HOTC Electronic Regulating Ballast Max SQ FT Range Lamp Potency µW/cm² @ 1 meter Ballast Warranty 16 " 120/230 36 Yes 4500 180 5 year 16"/5" 120/230 36/8 Yes 4500 180/12 5 year PCO2450 18" 120 50 Yes 4000 135 5 year MS24/MS24OZ 16" 24 36 Yes 4000 105 5 year GeneralAire Model Lamp Length GUV100A83 GUV25403A *MS24 requires 50VA Transformer (GA3501) 38 Distributed by: Our reputation rides on the products we provide, so don’t settle for less, expect the best with GENERALAire residential whole house humidifiers, air cleaners and air purifiers. For more than 65 years GENERALAire has designed and manufactured a full line of efficient and reliable residential indoor air quality products. We put more value in the box as our signature of commitment to you. General Filters, Inc. 43800 Grand River Avenue Novi, Michigan 48375 (248) 476-5100 (248) 349-2366 fax [email protected] Canadian General Filters, Ltd. 39 Crockford Blvd. · Scarborough, ON M1R 3B7 (416) 757-3691 · (416) 757-4687 fax [email protected]