wolf ventilation guide

Transcription

wolf ventilation guide
WOLF VENTILATION GUIDE
Contents
Important Note
Wolf Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wolf cooking products do not require ventilation when
installed according to the installation instructions.
Recommendations and suggestions in this guide are for
performance only.
Selecting a Ventilation System . . . . . . . . . . . . . . . . . . . 4
Ventilation Made Easy . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wolf Cooktop Ventilation . . . . . . . . . . . . . . . . . . . . . . 14
Wolf Pro Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Wolf Blower Specifications . . . . . . . . . . . . . . . . . . . . . 44
Wolf Ventilation FAQ . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Wolf Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Features and specifications are subject to change at any time
without notice. Visit our website, wolfappliance.com for the
most up-to-date information.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specified.
IMPORTANT NOTE: Wolf prefers an HVAC contractor
approve the airflow characteristics of any ventilation and duct
work system. This includes approval of what direction duct
runs and any variables related to installation that are not
called out in our specifications. Variance from our recommendations must be validated by an HVAC specialist as well as
verification of air flow and speeds to insure proper ventilation.
To ensure the safe and efficient use of Wolf equipment,
please take note of the following types of highlighted
information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION signals a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
Wolf Ventilation
3
wolfappliance.com/specs
Wolf Ventilation. Ventilation is an integral part of any kitchen. Proper ventilation provides a cleaner, healthier, more
enjoyable cooking environment by removing moisture, odor and unhealthy by-products of combustion, including carbon
monoxide. Proper ventilation is essential for maintaining a healthy indoor environment and minimizing airborne health risks.
Ventilation can provide a dramatic focal point for your kitchen or it can be concealed for an integrated look. Wolf ventilation
systems are precisely crafted for both function and design.
Choosing the proper ventilation system is one of the most important decisions you can make when designing your kitchen.
Wolf has ventilation products to satisfy all needs and preferences. When selecting a ventilation system, it is important to
note that Wolf ventilation systems are divided into two categories: cooktop ventilation and pro ventilation.
Cooktop ventilation.
Pro ventilation.
Selecting a Ventilation System
4
Selecting a Ventilation System
For Wolf ranges and rangetops, a pro ventilation hood or
hood liner should be used. A downdraft can be used with
sealed burner rangetop models SRT304 and SRT366. An
accessory trim kit is required for this installation. Contact
your authorized Wolf dealer for details.
COOKTOP OR PRO VENTILATION
Wolf cooktop ventilation hoods can be used with Wolf
induction, electric and gas cooktops and integrated
modules. Wolf downdraft systems can be used with Wolf
framed induction, framed electric and gas cooktops and
some integrated modules. Downdrafts cannot be installed
with unframed induction and unframed electric cooktops,
and steamer and fryer modules. They are not recommended for use with the grill module.
Wolf pro ventilation hoods and hood liners can be used
with all Wolf cooking appliances.
The chart below provides a reference of Wolf ventilation
products typically used with Wolf cooking appliances.
COOKTOP VENTILATION
PRO VENTILATION
CHIMNEY
HOODS
LOW-PROFILE
HOODS
DOWNDRAFT
SYSTEMS
WALL
HOODS
WALL CHIMNEY
HOODS
ISLAND
HOODS
HOOD
LINERS
Framed Induction Cooktops
•
•
•
•
•
•
•
Unframed Induction Cooktops
•
•
•
•
•
•
Framed Electric Cooktops
•
•
•
•
•
•
Unframed Electric Cooktops
•
•
•
•
•
•
Gas Cooktops
•
•
•
•
•
•
•
CT15I/S, CT15E/S and IM15/S
•
•
•
•
•
•
•
IG15/S, IS15/S and IF15/S
•
•
•
•
•
•
•
•
•
•
•
•
•
•
All Other Sealed Burner Rangetops
•
•
•
•
Gas Ranges
•
•
•
•
Gas Rangetops
•
•
•
•
COOKTOPS
•
INTEGRATED MODULES
RANGES AND RANGETOPS
Dual Fuel Ranges
SRT304 and SRT366
•
Selecting a Ventilation System
5
wolfappliance.com/specs
Selecting a Ventilation System
UPDRAFT OR DOWNDRAFT
HOOD MOUNTING HEIGHT
The choice between updraft ventilation and downdraft
ventilation will depend on several factors, most notably
the cooking appliance being used as well as the type of
installation and installation location. Updraft ventilation,
or an overhead hood, will typically be a more effective
ventilation option. Cooking vapors naturally rise, making it
easier to collect and remove them from the cooking area.
Proper mounting height is very important. If a ventilation
hood is mounted too low, access to the cooking surface
may be restricted. If a hood is mounted too high, performance may be compromised.
Wolf downdraft systems provide another effective ventilation option. The telescopic downdraft chimney rises up
from the countertop and draws cooking vapors away from
the cooking surface. Downdraft ventilation is a great
option in installations where an overhead hood is either
not wanted or is not a viable option.
WIDTH GUIDELINES
For wall installations, the width of the hood should be at
least as wide as the cooking surface. Where space is not
restricted, a wider hood can be used to increase the
capture area.
Island and peninsula installations require a greater capture
area. Island hoods should exceed the width of the cooking
surface by a minimum of 3" (76) on each side.
For downdraft ventilation systems, the width of the downdraft should match the width of the cooktop.
For optimal performance, cooktop hoods should be
mounted 24" (610) to 30" (762) from the bottom of the hood
to the countertop. For optimal performance, pro hoods
should be mounted 30" (762) to 36" (914) from the bottom
of the hood to the countertop. Refer to individual specifications for each ventilation hood on pages 14–41.
CEILING HEIGHT
Before selecting a Wolf ventilation hood, check the installation site for adequate ceiling height, or any extra space
that may remain after proper installation of the hood and
cooking appliance. This can be determined by adding the
floor-to-countertop height, plus the recommended hood
mounting height (bottom of the hood to the countertop),
plus the height of the hood. Refer to individual specifications for each ventilation hood on pages 14–41.
Excess ceiling height can be filled using an accessory
flue extension (available for some cooktops hoods) or a
stainless steel duct cover (pro hoods). The space can also
be adjusted by raising or lowering your hood within the
specified mounting height for your hood.
For additional ceiling height guidelines for cooktop wall
and island hoods, refer to page 15.
Selecting a Ventilation System
6
Selecting a Ventilation System
COOKING STYLE
INTERNAL, IN-LINE OR REMOTE BLOWER
The appropriate airflow capacity is determined by the
cooking space and cooking style. Greater exhaust
capacity is required to handle moisture generated by
boiling large pots of water or the grease and smoke from
grilling or frying. Cooking with high heat or cooking
aromatic foods may require additional CFM, and increasing the capture area with a hood that exceeds the cooking
surface by 3" (76) on each side.
With the exception of some cooktop low-profile hoods
and some downdrafts, Wolf ventilation products are
shipped without the blower assembly. An internal, in-line
or remote blower must be selected to accommodate the
Wolf cooking appliance.
If the cooking surface is in an island or peninsula, a higher
airflow capacity hood can provide better capture for cross
currents, or if the hood needs to be mounted higher.
Downdraft ventilation systems are also a good alternative.
VENTILATION PERFORMANCE
Ventilation performance is measured in cubic feet per
minute, or CFM. The higher the CFM, the greater the
amount of air that is evacuated through the ventilation
system. CFM are based on the cooking appliance output.
Wolf suggests 1 CFM per 100 Btu (.03 kW).
The chart on page 10 provides CFM for all Wolf cooking
appliances.
The blower will vary in size, which is dictated by the
cooking surface, the volume of air that needs to be moved
and the length of the duct run.
RECIRCULATING VENTILATION
Recirculating ventilation units are installed on top of a
ventilation hood with no ductwork required. Recirculating
units recycle the air through a charcoal filter and return it
to the kitchen. Wolf recirculating units are for use with
cooktop low-profile hoods with an internal blower and
some pro wall hood models. Recirculating units should
not be used with ranges or rangetops that contain a charbroiler or griddle. Refer to specifications for recirculating
ventilation on pages 42–43.
IMPORTANT NOTE: This type of ventilation will not remove
heat, moisture or combustion gases from the air. It will
also be less effective in reducing odors and smoke.
Selecting a Ventilation System
7
wolfappliance.com/specs
Selecting a Ventilation System
DUCTWORK CONSIDERATIONS
ELECTRICAL REQUIREMENTS
IMPORTANT NOTE: Unless used in a recirculating application, Wolf ventilation hoods and downdrafts must be
vented to the outside. Use only rigid metal ducting.
All Wolf ventilation products require a separate, grounded
electrical supply. Refer to the electrical requirements for
your specific ventilation product on pages 14–41. Locate
the electrical supply within the shaded area shown in the
installation illustration.
Typically, wall-mounted ventilation hoods can be vertical
or horizontal discharge, while wall chimney hoods, island
hoods and hood liners are vertical discharge only. For
some wall hoods, an accessory horizontal discharge kit is
required. In a horizontal discharge application, additional
framework may be needed to accommodate the remote
blower. Wolf downdraft systems have an adjustable
discharge that will allow you to negotiate ducting around
floor joists and other obstacles.
Depending on the specific installation, ductwork can run
through the roof, external wall or eave. Ductwork through
an eave requires an internal blower. Refer to individual
specifications for each ventilation hood on pages 14–41.
A straight, short duct run with a limited number of elbows
and transitions will allow the hood or downdraft to perform
most efficiently. Wolf ventilation hoods will operate most
efficiently when ductwork does not exceed 50' (15 m) in
length, 40' (12 m) for downdrafts. Refer to the chart on
page 9 to calculate total duct length.
IMPORTANT NOTE: Consult a qualified HVAC professional
for specific installation and ductwork applications.
You must follow all National Electrical Code regulations.
In addition, be aware of local codes and ordinances when
installing your service.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption
of operation.
CUSTOM HOOD APPLICATIONS
A custom decorative hood, used with pro hood liners,
can be created out of wood, plaster, tile or metal to match
virtually any design theme. The shape of the decorative
hood is not critical as long as the hood liner fits completely inside the hood. The decorative hood and liner
must fit together at the bottom edge in both width and
depth. The height of the hood does not have to match the
height of the liner. Interior dimensions of the decorative
hood must exceed exterior dimensions of the liner. Refer
to specifications for pro hood liners on pages 40–41.
Ventilation Made Easy
8
Ventilation Made Easy
After choosing your ventilation hood or downdraft, follow
this three-step process to determine your blower needs:
Step 1) Determine the Duct Run
Step 2) Determine the CFM
Step 3) Select a Blower Assembly
Step 1: Determine the Duct Run
Check local codes. Consult a qualified HVAC professional
to ensure that all local codes are followed. Always refer to
installation instructions for your specific Wolf ventilation
product.
Minimize the duct run and number of elbows and transitions. The length of the duct run and number of elbows
and transitions can have a significant effect on ventilation
performance. Keep the duct run as short as possible and
limit the number of elbows and transitions.
Do not place elbows and transitions back-to-back.
Whenever possible, include a minimum 15" (381) straight
ducting between elbows and transitions. Elbows and
transitions placed too close to each other will cause a
decrease in ventilation performance.
Use recommended duct sizes. Depending on the specific
ventilation product, Wolf recommends 8" (203) or 10" (254)
ducting. Smaller duct sizes will significantly reduce
ventilation performance. Refer to individual specifications
for each ventilation product on pages 14–41.
Do not use flexible metal ducting. Flexible metal ducting
will increase air resistance and is not recommended by the
National Uniform Mechanical Code Standards.
Do not use butt joints. Whenever possible, use male and
female connections with the male end pointing in the
direction of the airflow. Tightly tape joints to maximize
ventilation performance.
Cold weather installations. Cold weather installations
may require an additional backdraft damper to minimize
backward flow of cold air. It should be placed as close to
the roof or wall cap as possible. All Wolf ventilation hoods,
except low-profile wall hoods, come with a backdraft
damper connected to the transition. Downdraft systems
do not have a backdraft damper.
High altitudes. Ventilation systems are less effective at
altitudes above 5,000' (1524 m). At these altitudes, you
should estimate a 20%–25% reduction in CFM performance. Solutions include using a higher CFM blower and
increasing the duct size.
Make-up air may be required. Most newer homes have
tightly sealed doors and windows. Make-up air may be
needed to replace the air removed by the ventilation
system. Many heating and air conditioning systems
provide make-up air. Opening a window or door can be
an option but may be less effective. Consult a qualified
HVAC professional for specific applications.
Recirculating ventilation. Recirculating units recycle the
air through a charcoal filter and return it to the kitchen.
This type of ventilation will not remove heat, moisture or
combustion gases from the air. It will also be less effective
in reducing odors and smoke. Recirculating units should
only be used in applications where ductwork to the
outside is not an option, and only if local codes allow it.
Refer to specifications for recirculating ventilation on
pages 42–43.
Ventilation Made Easy
9
wolfappliance.com/specs
Step 1: Determine the Duct Run
Determining the equivalent duct length. Determine the
equivalent duct length for your installation using the
equivalent duct lengths for commonly used ducting. Refer
to the chart on the following page. The equivalent duct
length is calculated as follows:
1) Compute the length of all straight ducting.
2) Compute the equivalent duct length of all elbows,
transitions and caps.
3) Add equivalent lengths for all sections of the duct run.
EQUIVALENT DUCT LENGTHS
DUCTING
EQUIVALENT
LENGTH
SIZE
1' (.3 m) STRAIGHT DUCTING
6" (152) round
4' (1.2 m)
8" (203) round
1' (.3 m)
10" (254) round
.3' (.1 m)
3 1/4" (83) x 10" (152)
4' (1.2 m)
6" (152) round
24' (7.3 m)
8" (203) round
7' (2.1 m)
10" (254) round
3' (.9 m)
3 1/4" (83) x 10" (152)
12' (3.7 m)
6" (152) round
12' (3.7 m)
90° ELBOW
45° ELBOW
8" (203) round
4' (1.2 m)
10" (254) round
2' (.6 m)
3 1/4" (83) x 10" (152)
8' (2.4 m)
6" (152) round to 3 1/4" (83) x 10" (152)
5' (1.5 m)
ROUND TO RECTANGULAR TRANSITION
8" (203) round to
3 1/4"
(83) x 10" (152)
1' (.3 m)
3 1/4" (83) x 10" (152) to 6" (152) round
12' (3.7 m)
3 1/4" (83) x 10" (152) to 8" (203) round
16' (4.9 m)
6" (152) round to 8" (203) round
4' (1.2 m)
8" (203) round to 10" (254) round
1' (.3 m)
8" (203) round to 6" (152) round
12' (3.7 m)
10" (254) round to 8" (203) round
3' (.9 m)
6" (152) round
60' (18.3 m)
ROUND TO ROUND TRANSITION
ROOF CAP OR WALL CAP
8" (203) round
20' (6.1 m)
10" (254) round
9' (2.7 m)
3 1/4" (83) x 10" (152)
60' (18.3 m)
TOTAL
QUANTITY
TOTAL
Ventilation Made Easy
10
Step 2: Determine the CFM
The chart below provides CFM specific to the cooking
appliance and ventilation system used. CFM are based on
the cooking appliance output. Wolf suggests 1 CFM per
100 Btu (.03 kW). Additional CFM may be required for long
duct runs and ranges or rangetops with a charbroiler or
griddle.
When determining the proper CFM for your installation,
take into consideration the equivalent duct length calculated on the previous page.
IMPORTANT NOTE: Consult a qualified HVAC professional
for specific applications.
IMPORTANT NOTE: Specifing a blower with less CFM than
listed in the chart below will result in decreased airflow
and performance.
WOLF PRODUCT CFM
COOKTOP HOODS
DOWNDRAFTS
PRO HOODS
CFM
CFM
CFM
CT15I CT15E CT15G IG15* IS15* IF15* IM15
215
150
215
CT30I CT30IU* CT30E CT30EU* CT30G
450
350
500
CT36I CT36IU* CT36E CT36EU* CT36G
600
500
500
MODEL
COOKTOPS AND MODULES
DUAL FUEL RANGES
DF304
500
DF366 DF364C DF364G
900
DF486C DF486G DF484CG DF484DG DF484F
1100
DF606DG DF606F DF606CG DF604CF DF604GF
1500
SEALED BURNER RANGETOPS
SRT304
500
500
SRT366
500
900
SRT364C SRT364G
900
SRT486C SRT486G SRT484CG SRT484DG SRT484F
900
GAS RANGES
R304
500
R366 R364C R364G
900
R488 R486C R486G R484CG R484DG R484F
1100
R606DG R606F R606CG
1500
GAS RANGETOPS
RT366 RT364C RT364G RT362F
900
RT488 RT486C RT486G RT484CG RT484DG RT484F
1100
*Downdraft systems are not recommended for use with these models.
CFM are based the cooking appliance output. Wolf suggests 1 CFM per 100 Btu (.03 kW). Additional CFM may be required for long duct runs or
ranges and rangetops with a charbroiler or griddle.
Ventilation Made Easy
11
wolfappliance.com/specs
Step 3: Select a Blower
WOLF BLOWER ASSEMBLIES
IN-LINE BLOWERS
With the exception of some cooktop low-profile hoods
and some downdrafts, Wolf ventilation products are
shipped without the blower assembly. An internal, in-line
or remote blower must be selected to accommodate the
Wolf cooking appliance. Wolf blower assemblies are
available through your authorized Wolf dealer. For local
dealer information, visit the find a showroom section of
our website, wolfappliance.com.
In-line blowers are mounted between the hood and the
exterior of the home. Ductwork runs from the hood and
connects to the blower. More ductwork is attached to the
other side of the blower and runs to the exterior of the
home. This is a great option for those who do not want the
blower mounted inside the hood but cannot, or prefer not
to mount a remote blower on the exterior of the home.
IMPORTANT NOTE: Wolf ventilation products must be
installed only with a Wolf blower.
The chart on the following pages provides blower options
for all cooktop and pro ventilation products.
Installation instructions shipped with each Wolf blower
assembly provide detailed specifications.
INTERNAL BLOWERS
Internal blowers are mounted inside the hood canopy or
downdraft blower box and provide the least disruption to
the exterior of the home.
Internal blowers are available for all Wolf cooktop and pro
ventilation products. Refer to specifications for Wolf
internal blowers on pages 44–48.
In-line blowers are available for all Wolf cooktop and pro
ventilation products. Refer to specifications for Wolf in-line
blowers on pages 49–50 with additional planning information on pages 58–59.
REMOTE BLOWERS
Remote blowers can be mounted on the roof or, in some
cases, on an exterior wall. A remote-mounted blower will
minimize the amount of blower noise but will not eliminate
the noise completely.
Some blower noise is considered normal while the blower
is operational. If noise is a concern, a remote blower is
recommended. To reduce noise further for remote blower
applications, an attenuator may be necessary.
Remote blowers are available for all Wolf cooktop and pro
ventilation products. Refer to specifications for Wolf
remote blowers on pages 51–57 with additional planning
information on pages 60–62.
Ventilation Made Easy
12
Step 3: Select a Blower
INTERNAL
CFM
BLOWER
300*
450*
500
600
900
1200
814419
814420
810991
814421
814422
814423
COOKTOP HOODS
CTWH30
•
•
•
CTWH36 IH4227
•
•
•
•
•
•
COOKTOP LOW-PROFILE HOODS
CTEWH36 CTEWH45
DOWNDRAFTS
DD30R DD36R DD45R
PRO LOW-PROFILE WALL HOODS
PW302210 PW362210
•
PW422210 PW482210
PRO 24" (610) WALL HOODS
PW302418 PW362418 PW422418
•
•
PW482418 PW542418
•
•
PW602418 PW662418
•
•
PW302718 PW362718 PW422718
•
•
PW482718 PW542718
•
•
PW602718 PW662718
•
•
PWC362418 PWC422418
•
•
PWC482418 PWC542418
•
•
PI363418 PI423418
•
•
PI543418
•
•
PI663418
•
•
PL342212 PL402212
•
•
•
•
PL462212
•
•
•
•
•
PL522212
•
•
•
•
PL582212
•
•
•
•
•
PRO 27" (686) WALL HOODS
•
•
•
•
•
PRO WALL CHIMNEY HOODS
•
•
•
•
•
•
•
•
PRO ISLAND HOODS
•
•
PRO HOOD LINERS
*For make-up air restricted applications. Capture and performance may be reduced.
•
Ventilation Made Easy
13
wolfappliance.com/specs
Step 3: Select a Blower
IN-LINE
CFM
REMOTE
600
1100
600
900
1200
1500
808331
808332
801640
801641
801642
804701
CTWH30
•
•
•
•
•
•
CTWH36 IH4227
•
•
•
•
•
•
•
•
•
BLOWER
COOKTOP HOODS
COOKTOP LOW-PROFILE HOODS
CTEWH36 CTEWH45
•
•
DOWNDRAFTS
DD30R DD36R DD45R
•
PRO LOW-PROFILE WALL HOODS
PW302210 PW362210
•
•
•
PW422210 PW482210
•
•
•
PRO 24" (610) WALL HOODS
PW302418
•
•
PW362418 PW422418 PW482418 PW542418
•
PW602418 PW662418
•
•
•
•
•
•
•
•
•
•
PRO 27" (686) WALL HOODS
PW302718
•
•
PW362718 PW422718 PW482718 PW542718
•
PW602718 PW662718
•
•
•
•
•
•
•
•
•
•
PRO WALL CHIMNEY HOODS
PWC362418 PWC422418
•
•
•
•
PWC482418 PWC542418
•
•
•
•
PI363418 PI423418
•
•
•
•
PI543418
•
•
•
•
PI663418
•
•
•
PRO ISLAND HOODS
PRO HOOD LINERS
PL342212 PL402212
•
•
•
•
PL462212
•
•
•
•
PL522212
•
•
•
•
PL582212
•
•
•
•
Wolf Cooktop Ventilation
14
Wolf Cooktop Ventilation
COOKTOP CHIMNEY HOODS
DOWNDRAFT SYSTEMS
Wolf cooktop chimney hoods are crafted of seamless
stainless steel. Chimney wall and island hoods have a
telescopic flue which allows you to reach a ceiling height
of 8' (2.4 m) to 9' (2.7 m) with a finished look. A flue extension for 10' (3 m) ceilings is available as a sales accessory.
Wolf downdraft ventilation systems are crafted of stainless
steel. Downdrafts are available with an internal blower, or
some models have in-line and remote blower options.
Wolf cooktop chimney hoods can be used with all Wolf
cooktops and integrated modules.
COOKTOP LOW-PROFILE HOODS
Wolf cooktop low-profile hoods are crafted of stainless
steel with a black glass control panel. Low-profile wall and
island hoods have a telescopic chimney flue which allows
you to reach a ceiling height of 8' (2.4 m) to 9' (2.7 m) with a
finished look. Wall and island hoods are available with an
internal blower, or some wall hood models have in-line and
remote blower options.
Wolf downdraft systems can be used with Wolf framed
induction, framed electric and gas cooktops and some
integrated modules. A downdraft can be used with sealed
burner rangetop models SRT304 and SRT366. An accessory trim kit is required for this installation. Contact your
authorized Wolf dealer for details.
IMPORTANT NOTE: Wolf downdraft systems cannot be
installed with unframed induction and unframed electric
cooktops, and steamer and fryer modules. They are not
recommended for use with the grill module.
Refer to specifications for individual cooktop hoods and
downdraft systems on the following pages.
Wolf cooktop low-profile hoods can be used with all Wolf
cooktops and integrated modules.
Downdraft systems.
Cooktop chimney hoods.
Cooktop low-profile hoods.
Cooktop Ventilation Widths
WIDTH
Chimney Wall Hoods
30" (762)
36" (914)
•
•
•
•
Chimney Island Hoods
Low-Profile Wall Hoods
45" (1143)
•
Low-Profile Island Hoods
Downdrafts
42" (1067)
•
•
•
•
•
48" (1219)
54" (1372)
60" (1524)
66" (1676)
Wolf Cooktop Ventilation
15
wolfappliance.com/specs
Wolf Cooktop Ventilation Hoods
HOOD PLACEMENT
CALCULATE CHIMNEY FLUE HEIGHT
Installation of the cooktop wall or island hood should be
24" (610) to 30" (762) from the bottom of the hood to the
countertop. To determine placement of the cooktop hood,
you must calculate the height of the telescopic chimney
flue. The minimum and maximum flue extension for each
cooktop hood is listed in the charts below.
A) Height from finished floor to finished ceiling. 8' (2.4 m)
or 9' (2.7 m) ceilings are typical.
IMPORTANT NOTE: Both sections of the telescopic
chimney flue must be installed in order for the chimney to
be lifted for service.
B) Height from finished floor to countertop. A 36" (914)
countertop height is standard.
C) Hood mounting height (bottom of hood to countertop).
Dimension C must be between 24" (610) and 30" (762).
8' (2.4 m) ceilings may not allow the maximum 30" (762)
hood mounting height.
D) Calculate chimney flue height: D = A – (B + C).
Dimension D must be between the minimum and
maximum flue extension listed in the charts. Refer to
the illustration below.
Cooktop Chimney Hoods
FLUE EXTENSION
MINIMUM
MAXIMUM
CTWH30
30 1/2" (775)
48 1/2" (1232)
CTWH36
32 5/8"
50 7/8" (1292)
IH4227
33 1/2" (851)
(829)
47" (1194)
D
Cooktop Low-Profile Hoods
FLUE EXTENSION
MINIMUM
MAXIMUM
CTEWH30I
29 1/8" (740)
41 1/2" (1054)
CTEWH36(I)
29 1/8" (740)
41 1/2" (1054)
CTEWH45(I)
29 1/8"
(740)
41 1/2" (1054)
CTEIH42I
28 1/4"
(718)
41 1/2" (1054)
A
MINIMUM
FLUE
EXTENSION
C
B
Cooktop hood placement.
Wolf Cooktop Ventilation
16
Cooktop Chimney Wall Hood
Model Options
MODEL
WIDTH
WEIGHT
CTWH30
30" (762)
85 lbs (39 kg)
CTWH36
35 1/2"
100 lbs (45 kg)
(902)
HEIGHT
21"
WIDTH
(533)
FEATURES
Specifications
•
Heavy-duty, stainless steel seamless construction.
COOKTOP VENTILATION
•
Internal, in-line and remote blower options.
Installation Type
Wall
•
Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
Exterior Finish
Stainless Steel
Front-mounted controls with LED indicator and threespeed blower control.
Widths
30" (762) and 35 1/2" (902)
Height
(CTWH30) 6 7/8" (175)
(CTWH36) 9 1/4" (235)
Depth
21" (533)
Telescoping Height
(CTWH30) 30 1/2" (775)— 48 1/2" (1232)
(CTWH36) 32 5/8" (829)— 50 7/8" (1292)
•
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
•
Halogen lighting with three settings.
•
Delay-off feature to automatically turn unit off.
Installation Height
•
Filter clean timer lets you know when filters need
cleaning.
24" (610) to 30" (762)
bottom of hood to countertop
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
•
Stainless steel filter cover with dishwasher-safe
aluminum mesh filter.
Halogen Bulbs
Two or three T4, 12 V, 20 W
bulbs (included)
•
Transition with backdraft damper.
Discharge
Vertical
Duct Size
8" (203) Round
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
•
Flue extension to accommodate 10' (3 m) ceilings.
•
30" (762) high stainless steel wall shield.
•
8" (203) to 10" (254) round transition.
Blower Options
CFM
INTERNAL
300*
450*
500
600
CTWH30
•
•
•
CTWH36
•
•
•
IN-LINE
900
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
REMOTE
600
1100
600
900
1200
1500
•
•
•
•
•
•
•
•
•
•
•
•
Wolf Cooktop Ventilation
17
wolfappliance.com/specs
Cooktop Chimney Wall Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
18" (457)
LOCATE
ELECTRICAL
WITHIN
SHADED AREA
9" (229)
E
6"
301/2" (775) TO
48 1/2" (1232)
19 1/8"
(486)
OR
(152)
32 5/8" (829) TO
50 7/8" (1292)
4" (102)
6 7/8" (175)
TELESCOPING
HOOD HEIGHT
OR
12"
(305)
91/4" (235)
30" (762) OR 35 1/2" (902)
21" (535)
HOOD DEPTH
HOOD WIDTH
24" (610) TO 30" (762)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: 8' (2.4 m) ceilings can not accommodate 30" (762) from
bottom of hood to countertop. Based on 36" (914) countertop
height, an 8' (2.4 m) ceiling will allow for a maximum 29 1/2" (749)
for CTWH30 and 27 1/4" (692) for CTWH36, from bottom of hood
to countertop.
DUCTWORK
INSTALLATION
THROUGH
WALL
Wolf Cooktop Ventilation
18
Cooktop Chimney Island Hood
Model Options
MODEL
WIDTH
WEIGHT
IH4227
42" (1067)
110 lbs (50 kg)
9 1/4"
(235)
27"
(686)
42"
(1067)
FEATURES
Specifications
•
Heavy-duty, stainless steel seamless construction.
COOKTOP VENTILATION
•
Internal, in-line and remote blower options.
Installation Type
Island
•
Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
Exterior Finish
Stainless Steel
Front-mounted controls with LED indicator and threespeed blower control.
Width
42" (1067)
Height
9 1/4" (235)
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Depth
27" (686)
Telescoping Height
33 1/2" (851) to 47" (1194)
•
Halogen lighting with three settings.
Installation Height
24" (610) to 30" (762)
bottom of hood to countertop
•
Delay-off feature to automatically turn unit off.
Electrical Supply
•
Filter clean timer lets you know when filters need
cleaning.
120 V AC, 60 Hz, 15 amp
dedicated circuit
Halogen Bulbs
Stainless steel filter cover with dishwasher-safe
aluminum mesh filter.
Four T4, 12 V, 20 W bulbs
(included)
Discharge
Vertical
Duct Size
8" (203) Round
•
•
•
•
Transition with backdraft damper.
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
•
Flue extension to accommodate 10' (3 m) ceilings.
•
8" (203) to 10" (254) round transition.
Blower Options
CFM
IH4227
INTERNAL
300*
450*
•
•
500
IN-LINE
600
900
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
REMOTE
600
1100
600
900
1200
1500
•
•
•
•
•
•
Wolf Cooktop Ventilation
19
wolfappliance.com/specs
Cooktop Chimney Island Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
THROUGH TOP OF HOOD
18" (457)
DUCTWORK
INSTALLATION
THROUGH
EAVE—
INTERNAL
BLOWER
19 1/4"
(489)
9 1/4"
33 1/2" (851)
TO 47" (1194)
TELESCOPING
HOOD HEIGHT
12"
(305)
(235)
27" (686)
HOOD DEPTH
42" (1067)
HOOD WIDTH
24" (610) TO 30" (762)
BOTTOM OF
HOOD TO
COUNTERTOP
Wolf Cooktop Ventilation
20
Cooktop Low-Profile Wall Hood
Model Options
3 1/8"
MODEL
WIDTH
WEIGHT
CTEWH30I*
30" (762)
53 lbs (24 kg)
CTEWH36
36" (914)
51 lbs (23 kg)
CTEWH36I*
36" (914)
57 lbs (26 kg)
CTEWH45
45" (1143)
55 lbs (25 kg)
CTEWH45I*
45" (1143)
62 lbs (28 kg)
*Internal blower included.
(79)
17 3/4"
WIDTH
(451)
FEATURES
Specifications
•
Heavy-duty, stainless steel seamless construction.
COOKTOP VENTILATION
•
Internal, in-line and remote blower options.
Installation Type
Wall
•
Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
Exterior Finish
Stainless Steel
•
Front-mounted electronic controls with digital indicator
and four-speed blower control.
Widths
30" (762), 36" (914) and 45" (1143)
Height
3 1/8" (79)
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Depth
17 3/4" (451)
Telescoping Height
29 1/8" (740) to 41 1/2" (1054)
•
Halogen lighting with three settings.
Installation Height
24" (610) to 30" (762)
bottom of hood to countertop
•
Delay-off feature to automatically turn unit off.
Electrical Supply
•
Filter clean indicator.
120 V AC, 60 Hz, 15 amp
dedicated circuit
•
Stainless steel filter cover with dishwasher-safe
aluminum mesh filter.
Halogen Bulbs
Four T4, 12 V, 20 W bulbs
(included)
•
Transition with backdraft damper.
•
Discharge
Vertical
Duct Size
6" (152) Round
ACCESSORIES
•
In-line and remote blowers for CTEWH36 and CTEWH45
(refer to chart below).
•
30" (762) high stainless steel wall shield.
•
Recirculating kit and filter for non-ducted applications
(internal blower models).
Blower Options
CFM
CTEWH30I CTEWH36I CTEWH45I
CTEWH36 CTEWH45
INTERNAL
300
450
500
600
IN-LINE
900
1200
600
1100
REMOTE
600
Included
•
•
900
1200
1500
Wolf Cooktop Ventilation
21
wolfappliance.com/specs
Cooktop Low-Profile Wall Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
9 7/8"
10 7/8"
(251)
(276)
E
LOCATE
ELECTRICAL
WITHIN
SHADED
AREA
5"
(127)
15"
(381)
8' (2.4 m)
TO 9' (2.7 m)
CEILING
HEIGHT
29 1/8" (740)
TO 411/2" (1054)
TELESCOPING
HOOD HEIGHT
DUCTWORK
INSTALLATION
THROUGH
WALL
1
20 /8"
(511)
3 1/8" (79)
30" (762), 36" (914)
OR 45" (1143)
17 3/4" (451)
HOOD DEPTH
HOOD WIDTH
24" (610) TO 30" (762)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: For non-ducted applications with a recirculating kit, the
telescoping hood height is 31" (788) to 48 3/4" (1238).
Wolf Cooktop Ventilation
22
Cooktop Low-Profile Island Hood
Model Options
MODEL
WIDTH
WEIGHT
CTEIH42I*
42" (1067)
92 lbs (42 kg)
*Internal blower included.
3 1/8"
(79)
21 5/8"
(459)
42"
(1067)
FEATURES
Specifications
•
Heavy-duty, stainless steel seamless construction.
COOKTOP VENTILATION
•
Internal blower included.
Installation Type
Island
•
Telescopic flue fits 8' (2.4 m) to 9' (2.7 m) ceilings.
Exterior Finish
Stainless Steel
•
Front-mounted electronic controls with digital indicator
and four-speed blower control.
Width
42" (1067)
Height
3 1/8" (79)
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Depth
21 5/8" (459)
Telescoping Height
28 3/8" (721) to 40" (1016)
•
Halogen lighting with three settings.
Installation Height
24" (610) to 30" (762)
bottom of hood to countertop
•
Delay-off feature to automatically turn unit off.
Electrical Supply
•
Filter clean indicator.
120 V AC, 60 Hz, 15 amp
dedicated circuit
•
Stainless steel filter cover with dishwasher-safe
aluminum mesh filter.
Halogen Bulbs
Four T4, 12 V, 20 W bulbs
(included)
•
Transition with backdraft damper.
•
Discharge
Vertical
Duct Size
6" (152) Round
ACCESSORIES
•
Recirculating kit and filter for non-ducted applications.
Blower Options
CFM
CTEIH42I
INTERNAL
300
450
500
Included
600
IN-LINE
900
1200
600
1100
REMOTE
600
900
1200
1500
Wolf Cooktop Ventilation
23
wolfappliance.com/specs
Cooktop Low-Profile Island Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
THROUGH TOP OF HOOD
11 3/4"
(298)
22 7/8"
(581)
28 3/8" (721)
TO 40" (1016)
TELESCOPING
HOOD HEIGHT
DUCTWORK
INSTALLATION
THROUGH
EAVE—
INTERNAL
BLOWER
9 7/8"
(251)
3 1/8" (79)
21 5/8" (549)
HOOD DEPTH
42" (1067)
HOOD WIDTH
24" (610) TO 30" (762)
BOTTOM OF
HOOD TO
COUNTERTOP
8' (2.4 m)
TO 9' (2.7 m)
CEILING
HEIGHT
NOTE: For non-ducted applications with a recirculating kit, the
telescoping hood height is 30 3/4" (781) to 40" (1016).
Wolf Cooktop Ventilation
24
Downdraft Ventilation System
Model Options
9 1/8"
(232)
WIDTH
2 3/8"
(60)
MODEL
WIDTH
WEIGHT
DD30I*
30" (762)
90 lbs (41 kg)
DD30R
30" (762)
75 lbs (34 kg)
DD36I*
36" (914)
95 lbs (43 kg)
DD36R
36" (914)
80 lbs (36 kg)
DD45I*
45 1/2"
100 lbs (45 kg)
DD45R
45 1/2" (1156)
(1156)
85 lbs (39 kg)
*Internal blower included.
FEATURES
Specifications
•
Crafted of heavy-duty stainless steel.
COOKTOP VENTILATION
•
Downdraft chimney lowers beneath countertop when not
in use.
Installation Type
Downdraft
Exterior Finish
Stainless Steel
Stainless steel top trim and remote-mounted control
module with LED indicators.
Top Trim Widths
30" (762), 36" (914) and 45 1/2" (1156)
Chimney Widths
26 1/4" (667), 32 1/4" (819) and
41 1/4" (1048)
Height
9 1/8" (232) above countertop
Top Trim Depth
2 3/8" (60)
Chimney Depth
1 1/2" (38)
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
Power Cord
2 1/2' (.8 m) 3-prong
•
•
Three-speed blower control.
•
Delay-off feature to automatically turn unit off.
•
Filter clean timer lets you know when filters need
cleaning.
•
Dishwasher-safe aluminum mesh filters with stainless
steel filter covers.
ACCESSORIES
•
In-line and remote blowers for DD30R, DD36R and
DD45R (refer to chart below).
•
Support bracket for installation with two integrated
modules (DD30).
•
Trim kit for installation with sealed burner rangetop
(DD30 and DD36).
•
Transitions to round ductwork.
Blower Options
CFM
Adjustable
( I ) 31/4" (83) x 10" (254)
(R) 31/4" (83) x 14" (356)
INTERNAL
300*
450*
DD30I DD36I DD45I
DD30R DD36R DD45R
Discharge
Duct Size
500
600
IN-LINE
900
1200
600
REMOTE
1100
600
900
1200
1500
•
•
•
Included
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
•
Wolf Cooktop Ventilation
25
wolfappliance.com/specs
Downdraft Ventilation System
INSTALLATION WITH COOKTOP
INSTALLATION WITH SEALED BURNER RANGETOP
2 3/4" (70)
2 3/4" (70)
27" (686), 33" (838) OR 42" (1067)
27" (686) OR 33" (838)
DOWNDRAFT CUT-OUT
DOWNDRAFT CUT-OUT
25 1/8"
(638) min
FLAT
COUNTERTOP
3" (76) min
TO CONTROL
MODULE
30" (762) rec
3" (76) min
TO CONTROL
MODULE
19 1/4"
FLAT
COUNTERTOP
(489)
COOKTOP CUT-OUT
WIDTH
30" (762) OR 36" (914)
WIDTH OF RANGETOP
24"
(610) min*
21/2" (64) min
COUNTERTOP CUT-OUT (TOP VIEW)
21/2" (64) min
COUNTERTOP CUT-OUT (TOP VIEW)
21/2" (64) min
25 1/8" (638) min
FLAT COUNTERTOP
EDGE OF
COOKTOP
TO WALL
30" (762) rec
FLAT COUNTERTOP
EDGE OF
RANGETOP
TO WALL
7 1/2"
7 11/16" (197)
19" (483)
(191)
PLATFORM DEPTH
29 5/16"
29 5/16"
(745)
(745)
7 1/8"
7 1/8"
(181)
(181)
27 1/4" (692) min
CABINET DEPTH
24" min (610)
CABINET DEPTH
SIDE VIEW
SIDE VIEW
*Additional depth may be required if rangetop is to be installed flush with cabinet face.
NOTE: To install a downdraft with a Wolf cooktop, you must
allow for a minimum 251/8" (638) flat counter space from front to
back. A countertop with a raised lip or backsplash may not
allow enough space for proper installation.
Location of the electrical outlet must be within reach of the
power cord which is located midway, top and bottom, on the
right side of the downdraft. Unless oversized cabinets are used,
the outlet cannot be located on the back wall of the cabinet, but
may be placed in adjacent cabinetry.
Installation of the remote-mounted control module must be
within 10' (3 m) of the downdraft assembly and a minimum of
4" (102) from the outer edge of cooktop element or burner.
Wolf Cooktop Ventilation
26
Downdraft Ventilation System
SIDE DISCHARGE
BOTTOM DISCHARGE
COUNTERTOP
CUT-OUT
COUNTERTOP
CUT-OUT
ADJUSTMENT
B
B
A
RIGHT
DISCHARGE
LOCATION
ADJUSTMENT
A
C
C
LEFT
DISCHARGE
LOCATION
BOTTOM DISCHARGE
LOCATION
DISCHARGE CUT-OUT:
DISCHARGE CUT-OUT:
101/4" (260) x 31/2" (89) INTERNAL BLOWER
141/4" (362) x 31/2" (89) IN-LINE OR REMOTE
101/4" (260) x 31/2" (89) INTERNAL BLOWER
141/4" (362) x 31/2" (89) IN-LINE OR REMOTE
Side Discharge
BLOWER
Bottom Discharge
INTERNAL
IN-LINE / REMOTE
BLOWER
INTERNAL
IN-LINE / REMOTE
Dimension A
22 1/8"
19" (483)
Adjustment A
N/A
5" (127) MAX
Dimension B
16 3/8" (416)
211/2" (546)
Adjustment B
1" (25) TO 7" (178)
2 1/2" (165) MAX
Dimension C
5 1/2" (140)
4 1/4" (108)
Dimension C
5 1/2" (140)
4 1/4" (108)
(562)
NOTE: Wolf downdraft systems have an adjustable discharge
that will allow you to negotiate ducting around floor joists and
other obstacles. Three different discharge locations (left side,
right side or bottom) allow side-to-side adjustment for accurate
alignment of ductwork.
Wolf Cooktop Ventilation
27
wolfappliance.com/specs
Downdraft Ventilation System
DUCTWORK OPTIONS
10" (254) REMOTE
ROUND
DUCT
BLOWER
WALL CAP
12" (305) MIN
TO
GROUND
Internal blower through wall.
Remote blower through roof.
REMOTE
BLOWER
10" (254)
ROUND
DUCT
WALL CAP
12" (305) MIN
TO
GROUND
12" (305)
MIN TO
GROUND
Internal blower through wall.
Remote blower through wall.
Wolf Pro Ventilation
28
Wolf Pro Ventilation
Wolf pro ventilation is available in a wide variety of styles
and sizes to meet virtually any application, including hood
liners for installation with a custom decorative hood. Wolf
pro ventilation hoods and hood liners can be used with all
Wolf cooking appliances. Refer to specifications for individual pro ventilation products on the following pages.
Installation of pro hoods and hood liners should be
30" (762) to 36" (914) from the bottom of the hood to the
countertop.
PRO WALL HOODS
Pro wall ventilation hoods are crafted of seamless stainless steel and available in three styles. Low-profile hoods
are 22" (559) deep and 10" (254) high, while the pro 24"
(610) and 27" (686) deep wall hoods are 18" (381) high.
All three styles come in a variety of widths. Refer to the
chart on the following page. Pro 27" (686) deep wall hoods
feature heat lamps.
PRO ISLAND HOODS
Pro island hoods are crafted of seamless stainless steel.
The width of the island hood should exceed the width of
the cooking surface by a minimum of 3" (76) on each side.
PRO HOOD LINERS
Pro ventilation hood liners are available to accommodate
custom decorative hoods. The custom decorative hood
can be created out of wood, plaster, tile or metal to match
virtually any design theme.
The shape of the decorative hood is not critical as long as
the hood liner fits completely inside the hood. The decorative hood and liner must fit together at the bottom edge in
both width and depth. The height of the hood does not
have to match the height of the liner. Interior dimensions
of the decorative hood must exceed exterior dimensions
of the liner.
IMPORTANT NOTE: For optimal performance, a pro
27" (686) deep wall hood should be used with ranges and
rangetops that contain a charbroiler or griddle.
PRO WALL CHIMNEY HOODS
Pro wall chimney hoods are crafted of seamless stainless
steel. Optional duct covers in a variety of heights are available to complete the chimney design.
Pro island hoods.
Pro wall hoods.
Pro wall chimney hoods.
Pro hood liners.
Wolf Pro Ventilation
29
wolfappliance.com/specs
Wolf Pro Ventilation
Pro Ventilation Widths
WIDTH
30" (762)
36" (914)
42" (1067)
Low-Profile Wall Hoods
•
•
•
45" (1143)
48" (1219)
•
54" (1372)
60" (1524)
66" (1676)
24" Deep Wall Hoods
•
•
•
27" Deep Wall Hoods
•
•
•
•
•
•
•
•
•
•
Wall Chimney Hoods
•
•
•
•
•
Island Hoods
•
•
Hood Liners
•
•
•
•
•
•
•
Wolf Pro Ventilation
30
Pro Low-Profile Wall Hood
Model Options
10"
(254)
22"
WIDTH
(559)
FEATURES
MODEL
WIDTH
WEIGHT
PW302210
30" (762)
39 lbs (18 kg)
PW362210
36" (914)
44 lbs (20 kg)
PW422210
42" (1067)
50 lbs (23 kg)
PW482210
48" (1219)
55 lbs (25 kg)
Specifications
•
Heavy-duty, brushed stainless steel exterior with
enclosed liner.
PRO VENTILATION
Installation Type
Wall
•
Internal, in-line and remote blower options.
Exterior Finish
Stainless Steel
•
Welded seams, hemmed edges and hand-finished
craftsmanship.
Widths
30" (762), 36" (914), 42" (1067)
and 48" (1219)
•
Recessed easy-access controls.
Height
10" (254)
Depth
22" (559)
Installation Height
30" (762) to 36" (914)
bottom of hood to countertop
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
Halogen Bulbs
Two or three 50 W, 120 V par 20
bulbs (included)
•
Infinite-speed blower control.
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
•
Halogen lighting with two settings.
•
Removable, dishwasher-safe stainless steel baffle filters.
Discharge
Vertical or Horizontal
ACCESSORIES
Duct Size
10" (254) Round
•
Internal, in-line and remote blowers (refer to chart below).
Transition
•
38" (965) high stainless steel backsplash with or without
warming racks.
3 1/4" (83) x 14" (356) cut-out
(transition included with
internal blower)
•
6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high
stainless steel duct covers.
•
Recirculating kit and filter for non-ducted applications—
30" (762) and 36" (914) wide models with internal blower.
Blower Options
CFM
PW302210 PW362210
PW422210 PW482210
INTERNAL
300
450
500
•
600
IN-LINE
900
1200
600
1100
REMOTE
600
900
•
•
•
•
•
•
1200
1500
Wolf Pro Ventilation
31
wolfappliance.com/specs
Pro Low-Profile Wall Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
(127)
12"
10" (254)
HOOD HEIGHT
(305)
4" (102)
30" (762), 36" (914)
42" (1067) OR 48" (1219)
22" (559)
HOOD DEPTH
HOOD WIDTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: Pro low-profile wall hoods come standard with
vertical or horizontal discharge.
Wolf Pro Ventilation
32
Pro 24" Deep Wall Hood
Model Options
18"
(457)
24"
WIDTH
(610)
MODEL
WIDTH
WEIGHT
PW302418
30" (762)
67 lbs (30 kg)
PW362418
36" (914)
78 lbs (35 kg)
PW422418
42" (1067)
86 lbs (39 kg)
PW482418
48" (1219)
94 lbs (43 kg)
PW542418
54" (1372)
106 lbs (48 kg)
PW602418
60" (1524)
116 lbs (53 kg)
PW662418
66" (1676)
126 lbs (57 kg)
FEATURES
•
Heavy-duty, brushed stainless steel exterior with
enclosed liner.
PRO VENTILATION
•
Internal, in-line and remote blower options.
Installation Type
Wall
•
Hand-finished, welded seams and hemmed edges.
Exterior Finish
Stainless Steel
•
Recessed easy-access controls.
Widths
•
Infinite-speed blower control.
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372), 60" (1524)
and 66" (1676)
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Height
18" (457)
Depth
24" (610)
•
Halogen lighting with two settings.
Installation Height
•
Removable, dishwasher-safe stainless steel baffle filters.
30" (762) to 36" (914)
bottom of hood to countertop
•
Transition with backdraft damper.
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
•
Horizontal discharge with accessory kit.
Halogen Bulbs
Two or three 50 W, 120 V par 20
bulbs (included)
Discharge
Vertical or Horizontal
(requires horizontal discharge kit)
Specifications
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
Duct Size
10" (254) Round
•
38" (965) high stainless steel backsplash with or without
warming racks.
Transition
Rectangle to 10" (254) round,
9" (229) height (included)
•
6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high
stainless steel duct covers.
•
Horizontal discharge kit.
•
Recirculating kit and filter for non-ducted applications—
30" (762) and 36" (914) wide models with internal blower.
Blower Options
CFM
INTERNAL
500
IN-LINE
300*
450*
600
900
PW302418
•
•
•
•
PW362418
•
•
•
•
PW422418
•
•
•
•
PW482418 PW542418
•
•
PW602418 PW662418
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
REMOTE
600
1100
600
900
1200
•
•
•
•
•
1500
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wolf Pro Ventilation
33
wolfappliance.com/specs
Pro 24" Deep Wall Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
12"
(127)
(305)
18" (457)
HOOD HEIGHT
4" (102)
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372)
60" (1524) OR 66" (1676)
HOOD WIDTH
24" (610)
HOOD DEPTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: Alternative horizontal discharge requires accessory kit.
Refer to instructions provided with kit for detailed specifications.
Wolf Pro Ventilation
34
Pro 27" Deep Wall Hood
Model Options
18"
(457)
27"
WIDTH
(686)
FEATURES
MODEL
WIDTH
WEIGHT
PW302718
30" (762)
69 lbs (31 kg)
PW362718
36" (914)
80 lbs (36 kg)
PW422718
42" (1067)
88 lbs (40 kg)
PW482718
48" (1219)
96 lbs (44 kg)
PW542718
54" (1372)
108 lbs (49 kg)
PW602718
60" (1524)
118 lbs (54 kg)
PW662718
66" (1676)
128 lbs (58 kg)
Specifications
•
Heavy-duty, brushed stainless steel exterior with
enclosed liner.
PRO VENTILATION
Installation Type
Wall
•
Internal, in-line and remote blower options.
Exterior Finish
Stainless Steel
•
Hand-finished, welded seams and hemmed edges.
Widths
•
Recessed easy-access controls.
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372), 60" (1524)
and 66" (1676)
•
Infinite-speed blower control.
Height
18" (457)
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Depth
27" (686)
Installation Height
30" (762) to 36" (914)
bottom of hood to countertop
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
Halogen Bulbs
Two or three 50 W, 120 V par 20
bulbs (included)
Heat Lamp Bulbs
Two R40 250 W, 120 V, 60 Hz
infrared bulbs (not included)
Discharge
Vertical or Horizontal
(requires horizontal discharge kit)
•
Halogen lighting with two settings.
•
Heat lamp receptacles (bulbs not included).
•
Removable, dishwasher-safe stainless steel baffle filters.
•
Transition with backdraft damper.
•
Horizontal discharge with accessory kit.
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
•
38" (965) high stainless steel backsplash with or without
warming racks.
•
6" (152), 12" (305), 18" (457), 24" (610) and 30" (762) high
stainless steel duct covers.
•
Horizontal discharge kit.
Blower Options
CFM
Duct Size
10" (254) Round
Transition
Rectangle to 10" (254) round,
9" (229) height (included)
INTERNAL
500
IN-LINE
300*
450*
600
900
PW302718
•
•
•
•
PW362718
•
•
•
•
PW422718
•
•
•
•
PW482718 PW542718
•
•
PW602718 PW662718
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
REMOTE
600
1100
600
900
1200
•
•
•
•
•
1500
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wolf Pro Ventilation
35
wolfappliance.com/specs
Pro 27" Deep Wall Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
E
5"
12"
(127)
(305)
18" (457)
HOOD HEIGHT
4" (102)
30" (762), 36" (914), 42" (1067)
48" (1219), 54" (1372)
60" (1524) OR 66" (1676)
HOOD WIDTH
27" (686)
HOOD DEPTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: Alternative horizontal discharge requires accessory kit.
Refer to instructions provided with kit for detailed specifications.
Wolf Pro Ventilation
36
Pro Wall Chimney Hood
Model Options
18"
(457)
24"
MODEL
WIDTH
WEIGHT
PWC362418
36" (914)
78 lbs (35 kg)
PWC422418
42" (1067)
86 lbs (39 kg)
PWC482418
48" (1219)
94 lbs (43 kg)
PWC542418
54" (1372)
106 lbs (48 kg)
WIDTH
(610)
FEATURES
Specifications
•
Install with accessory duct cover for chimney-style hood.
PRO VENTILATION
•
Heavy-duty, brushed stainless steel exterior with
enclosed liner.
Installation Type
Wall
Exterior Finish
Stainless Steel
•
Internal, in-line and remote blower options.
Widths
•
Welded seams, hemmed edges and hand-finished
craftsmanship.
36" (914), 42" (1067), 48" (1219)
and 54" (1372)
Height
18" (457)
Depth
24" (610)
Installation Height
30" (762) to 36" (914)
bottom of hood to countertop
•
Recessed easy-access controls.
•
Infinite-speed blower control.
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
•
Halogen lighting with two settings.
Halogen Bulbs
Two or three 50 W, 120 V par 20
bulbs (included)
•
Removable, dishwasher-safe stainless steel baffle filters.
•
Transition with backdraft damper.
Discharge
Vertical
Duct Size
10" (254) Round
Transition
Rectangle to 10" (254) round,
7" (178) height (included)
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
•
38" (965) high stainless steel backsplash with or without
warming racks.
•
6" (152), 12" (305), 18" (457), 24" (610) high stainless steel
duct covers.
Blower Options
CFM
INTERNAL
300*
450*
PWC362418 PWC422418
•
•
PWC482418 PWC542418
•
•
500
IN-LINE
600
900
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
600
REMOTE
1100
900
1200
1500
•
600
•
•
•
•
•
•
•
Wolf Pro Ventilation
37
wolfappliance.com/specs
Pro Wall Chimney Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
5"
LOCATE
(127)
ELECTRICAL
WITHIN
6"
E
SHADED AREA (152)
WIDTH MINUS
18" (457)
OPTIONAL
DUCT COVER
13 1/2"
(343)
18" (457)
HOOD HEIGHT
4" (102)
36" (914), 42" (1067)
48" (1219) OR 54" (1372)
24" (610)
HOOD DEPTH
HOOD WIDTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
Wolf Pro Ventilation
38
Pro Island Hood
Model Options
18"
(457)
34"
MODEL
WIDTH
WEIGHT
PI362418
36" (914)
95 lbs (43 kg)
PI422418
42" (1067)
103 lbs (47 kg)
PI542418
54" (1372)
128 lbs (58 kg)
PI662418
66" (1676)
168 lbs (76 kg)
WIDTH
(864)
FEATURES
Specifications
•
Heavy-duty, brushed stainless steel exterior with
enclosed liner.
PRO VENTILATION
Installation Type
Island
•
Internal, in-line and remote blower options.
Exterior Finish
Stainless Steel
•
Welded seams, hemmed edges and hand-finished
craftsmanship.
Widths
36" (914), 42" (1067), 54" (1372)
and 66" (1676)
•
Recessed easy-access controls.
Height
18" (457)
Depth
34" (864)
Installation Height
30" (762) to 36" (914)
bottom of hood to countertop
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
Halogen Bulbs
Two or three 50 W, 120 V par 20
bulbs (included)
•
Infinite-speed blower control.
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
•
Halogen lighting with two settings.
•
Removable, dishwasher-safe stainless steel baffle filters.
•
Transition with backdraft damper.
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
•
6" (152), 12" (305), 18" (457), 24" (610) high stainless steel
duct covers.
Blower Options
CFM
Discharge
Vertical
Duct Size
10" (254) Round
Transition
Rectangle to 10" (254) round,
61/2" (165) height (included)
INTERNAL
300*
450*
PI363418 PI423418
•
•
PI543418
•
•
PI663418
•
•
500
IN-LINE
600
900
1200
900
1200
1500
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
600
REMOTE
1100
600
Wolf Pro Ventilation
39
wolfappliance.com/specs
Pro Island Hood
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
THROUGH
TOP OF HOOD
WIDTH MINUS
18" (457)
13"
18" (457)
(330)
HOOD HEIGHT
4" (102)
36" (914), 42" (1067)
54" (1372) OR 66" (1676)
34" (864)
HOOD DEPTH
HOOD WIDTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: Do not run electrical wiring through ductwork.
Wolf Pro Ventilation
40
Pro Hood Liner
Model Options
12"
(305)
22 1/2"
WIDTH
(572)
FEATURES
MODEL
WIDTH
WEIGHT
PL342212
34 3/8" (873)
44 lbs (20 kg)
PL402212
40 3/8" (1026)
50 lbs (23 kg)
PL462212
46 3/8" (1178)
55 lbs (25 kg)
PL522212
52 3/8" (1330)
60 lbs (27 kg)
PL582212
58 3/8"
65 lbs (29 kg)
(1483)
Specifications
•
Heavy-duty stainless steel enclosed liner for custom
hood applications.
PRO VENTILATION
Installation Type
Wall Hood Liner
•
Internal, in-line and remote blower options.
Exterior Finish
Stainless Steel
•
Recessed easy-access controls.
Widths
•
Infinite-speed blower control.
34 3/8" (873), 40 3/8" (1026)
46 3/8" (1178), 52 3/8" (1330)
and 58 3/8" (1483)
•
Heat sentry to automatically turn unit on when heat is
sensed and to adjust blower speed.
Height
12" (305)
Depth
22 1/2" (572)
•
Halogen lighting with two settings.
Installation Height
•
Removable, dishwasher-safe stainless steel baffle filters.
30" (762) to 36" (914)
bottom of hood to countertop
•
Transition with backdraft damper.
Electrical Supply
120 V AC, 60 Hz, 15 amp
dedicated circuit
Halogen Bulbs
Two 50 W, 120 V par 20 bulbs
(included)
ACCESSORIES
•
Internal, in-line and remote blowers (refer to chart below).
Blower Options
CFM
Discharge
Vertical
Transition
221/2 (572) x 9 5/8 (244) to 10" (254)
round, 8 3/4 (222) height (included)
INTERNAL
500
IN-LINE
300*
450*
600
900
PL342212 PL402212
•
•
•
•
PL462212
•
•
•
•
PL522212
•
•
PL582212
•
•
•
*For make-up air restricted applications. Capture and performance may be reduced.
1200
•
600
REMOTE
1100
900
1200
1500
•
600
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Wolf Pro Ventilation
41
wolfappliance.com/specs
Pro Hood Liner
INSTALLATION
DUCTWORK INSTALLATION
THROUGH ROOF
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
E
(152)
5"
DECORATIVE HOOD
(127)
WIDTH MINUS 6" (152)
12"
12" (305)
(305)
LINER HEIGHT
4" (102)
34 3/8" (873), 40 3/8" (1026)
46 3/8" (1178), 52 3/8" (1330)
OR 58 3/8" (1483) LINER WIDTH
221/2" (572)
LINER DEPTH
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
NOTE: A custom decorative hood can be created out of wood,
plaster, tile or metal. The shape of the decorative hood is not
critical as long as the hood liner fits completely inside the hood.
The decorative hood and liner must fit together at the bottom
edge in both width and depth. The height of the hood does not
have to match the height of the liner. Interior dimensions of the
decorative hood must exceed exterior dimensions of the liner.
Wolf Pro Ventilation
42
Recirculating Ventilation
Recirculating units are an alternative option for customers
required by code to install make-up air systems or where
running ventilation ductwork is an issue. They are also an
alternative option to ductwork for high rise buildings and
apartments. No ductwork is required for the recirculating
ventilation unit.
IMPORTANT NOTE: Wolf recirculating ventilation units
should not be used with Wolf range or rangetop models
with a charbroiler or griddle.
FEATURES
•
Heavy-duty stainless steel unit fits above ventilation
hood for recirculating applications.
•
No ductwork required.
•
Charcoal filters.
ACCESSORIES
•
Replacement charcoal filters.
Model Options
MODEL
WIDTH
WEIGHT
811838
30" (762)
20 lbs (9 kg)
811839
36" (914)
23 lbs (10 kg)
Specifications
RECIRCULATING
Installation Type
Wall
Exterior Finish
Stainless Steel
Widths
30" (762) and 36" (914)
Height
4" (102)
Depth
12" (305)
Pro Hoods
PW302210, PW362210,
PW302418, PW362418,
PW302718 and PW362718
Wolf Pro Ventilation
43
wolfappliance.com/specs
Recirculating Ventilation
INSTALLATION
5"
(127)
LOCATE ELECTRICAL
WITHIN SHADED AREA
6"
(152)
RECIRCULATING UNIT
E
4" (102)
10" (254) OR 18" (457)
HOOD HEIGHT
30" (762) OR 36" (914)
HOOD AND RECIRCULATING
UNIT WIDTH
12"
(305)
22" (559)
24" (610) OR 27" (686)
30" (762) TO 36" (914)
BOTTOM OF
HOOD TO
COUNTERTOP
HOOD DEPTH
Wolf Blower Specifications
44
Internal Blower Specifications
450 CFM INTERNAL BLOWER
600 CFM INTERNAL BLOWER
Specifications
Specifications
801643
801644
Cooktop Hoods
CTWH30
Cooktop Hoods
CTWH36 and IH4227
Duct Size
8" (203) Round
Duct Size
8" (203) Round
Electrical Rating
2.4 amps at 120 V AC, 60 Hz
Electrical Rating
3.0 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Roof or Wall Cap
Required
Shipping Weight
14 lbs (6 kg)
Shipping Weight
15 lbs (7 kg)
1.0
1.0
0.9
0.8
Static Pressure (in-wg)
Static Pressure (in-wg)
0.9
Calculated for Rigid
10" Galvanized Duct
0.8
0.7
0.6
0.5
0.4
High
Med
0.3
0.2
0
100
200
300
400
Airflow Rate (CFM)
0.6
High
Med
0.5
0.4
Low
0.3
0.2
Low
100'
75'
50'
25'
10'
0.1
0
Calculated for Rigid
10" Galvanized Duct
0.7
500
100'
75'
50'
25'
10'
0.1
600
Airflow rate with cooktop hoods.
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
0
0
100
200
300
400
Airflow Rate (CFM)
Airflow rate with cooktop hoods.
500
600
700
Wolf Blower Specifications
45
wolfappliance.com/specs
Internal Blower Specifications
900 CFM INTERNAL BLOWER
Specifications
801645
Cooktop Hoods
CTWH36 and IH4227
Duct Size
8" (203) Round
Electrical Rating
2.4 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Shipping Weight
26 lbs (12 kg)
Wolf Blower Specifications
46
Internal Blower Specifications
500 CFM INTERNAL BLOWER
600 CFM INTERNAL BLOWER
Specifications
Specifications
810991
810559
Pro Hoods
PW302210 and PW362210
Duct Size
8" (203) or 10" (254) Round
(depending on hood)
Electrical Rating
1.8 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Shipping Weight
15 lbs (7 kg)
Pro Hoods
PW302418, PW362418,
PW422418, PW302718,
PW362718 and PW422718
Duct Size
8" (203) or 10" (254) Round
(depending on hood)
Electrical Rating
3.8 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Shipping Weight
15 lbs (7 kg)
Wolf Blower Specifications
47
wolfappliance.com/specs
Internal Blower Specifications
900 CFM INTERNAL BLOWER
1200 CFM INTERNAL BLOWER
Specifications
Specifications
811131
810316
Pro Hoods
PW302418, PW362418,
PW422418, PW302718,
PW362718 and PW422718
Pro Hoods
Duct Size
10" (254) Round
Electrical Rating
7.6 amps at 120 V AC, 60 Hz
Duct Size
10" (254) Round
Roof or Wall Cap
Required
Electrical Rating
3.4 amps at 120 V AC, 60 Hz
Shipping Weight
30 lbs (14 kg)
Roof or Wall Cap
Required
Shipping Weight
34 lbs (15 kg)
1.1
1.0
1.0
0.9
Calculated for Rigid
10" Galvanized Duct
0.7
0.6
Calculated for Rigid
10" Galvanized Duct
0.9
Static Pressure (in-wg)
Static Pressure (in-wg)
0.8
High
0.5
0.4
Low
0.3
100'
0.2
75'
0.8
High
0.7
0.6
0.5
0.4
100'
0.3
75'
0.2
50'
0.1
25'
10'
50'
0.1
0
PW482418, PW542418,
PW602418, PW662418,
PW482718, PW542718,
PW602718 and PW662718
25'
10'
0
100
200
300
400
500
Airflow Rate (CFM)
Airflow rate with pro wall hoods.
600
700
800
0
0
100
200
300
400
500
600
Airflow Rate (CFM)
Airflow rate with pro wall hoods.
700
800
900
1000
Wolf Blower Specifications
48
Internal Blower Specifications
1200 CFM INTERNAL BLOWER
1200 CFM INTERNAL BLOWER
Specifications
Specifications
804703
805087
PWC482418 and PWC542418
All pro island hoods
Pro Hoods
All pro hood liners
Duct Size
10" (254) Round
Duct Size
10" (254) Round
Electrical Rating
3.4 amps at 120 V AC, 60 Hz
Electrical Rating
4.5 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Roof or Wall Cap
Required
Shipping Weight
34 lbs (15 kg)
Shipping Weight
27 lbs (12 kg)
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
1.0
Calculated for Rigid
10" Galvanized Duct
0.9
Calculated for Rigid
10" Galvanized Duct
0.8
High
100'
75'
Low
Static Pressure (in-wg)
Static Pressure (in-wg)
Pro Hoods
0.7
0.6
High
0.5
0.4
0.3
50'
0.2
25'
0.1
100'
75'
50'
25'
10'
10'
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
Airflow Rate (CFM)
Airflow rate with pro island hoods.
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
0
0
100
200
300
400
500
Airflow Rate (CFM)
Airflow rate with pro hood liners.
600
700
800
Wolf Blower Specifications
49
wolfappliance.com/specs
In-line Blower Specifications
600 CFM IN-LINE BLOWER
Specifications
808331
Dimensions (W x H x D)
24 3/8" (619) x 11 3/4" (298) x 121/4" (311)
Cooktop Hoods
CTWH30, CTWH36 and IH4227
Pro Hoods
All pro low-profile wall hoods
PW302418 and PW302718
Duct Size
10" (254) Round
Transition
41/2" (114) x 181/2" (470)
to 10" (254) Round
(two transitions included)
Electrical Rating
2.9 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Shipping Weight
44 lbs (20 kg)
24 3/8"
(619)
11 3/4"
(298)
18 1/2"
(470)
4 1/2"
(114)
211/2"
(546)
12 1/4"
(311)
600 CFM in-line blower.
Wolf Blower Specifications
In-line Blower Specifications
1100 CFM IN-LINE BLOWER
Specifications
808332
Dimensions (W x H x D)
24 7/8" (632) x 18" (457) x 18" (457)
Cooktop Hoods
CTWH30, CTWH36 and IH4227
Downdrafts
DD30R, DD36R and DD45R
Pro Hoods
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
Duct Size
10" (254) Round
Transition
8 1/2" (216) x 12" (305)
to 10" (254) Round
(two transitions included)
Electrical Rating
5.0 amps at 120 V AC, 60 Hz
Roof or Wall Cap
Required
Shipping Weight
63 lbs (29 kg)
24 7/8"
(632)
18"
(457)
12"
(305)
8"
(203)
22"
(559)
1100 CFM in-line blower.
18"
(457)
50
Wolf Blower Specifications
51
wolfappliance.com/specs
Remote Blower Specifications
600 CFM REMOTE BLOWER
1.0
Specifications
Calculated for Rigid
10" Galvanized Duct
0.9
801640
Cooktop Hoods
CTWH30, CTWH36 and IH4227
x
24 1/2" (622)
x
4 3/4" (121)
Pro Hoods
All pro low-profile wall hoods
PW302418 and PW302718
Duct Size
10" (254) Round
Electrical Rating
2.4 amps at 120 V AC, 60 Hz
Shipping Weight
32 lbs (15 kg)
Static Pressure (in-wg)
Dimensions (W x H x D)
21 3/4" (527)
0.8
0.7
100'
75'
50'
25'
Hood Only
High
0.6
Med
0.5
Low
0.4
0.3
0.2
0.1
0
0
100
200
300
400
Airflow Rate (CFM)
500
600
700
Airflow rate with cooktop hoods.
20 3/4"
(718)
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
(527)
28 1/4"
10" (254)
DIAMETER
15 1/2"
(394)
24 1/2"
(622)
14"
(356)
4 3/4"
24 3/4"
(629)
900 CFM remote blower.
(121)
Wolf Blower Specifications
52
Remote Blower Specifications
900 CFM REMOTE BLOWER
100'
50'
Downdraft Only
1.1
Specifications
Calculated for Rigid
10" Galvanized Duct
1.0
801641
Dimensions (W x H x D)
21 3/4" (527) x 24 1/2" (622) x 4 3/4" (121)
Cooktop Hoods
CTWH30, CTWH36 and IH4227
Downdrafts
DD30R, DD36R and DD45R
Pro Hoods
All pro low-profile wall hoods
PW302418, PW362418, PW422418
PW482418 and PW542418
PW302718, PW362718, PW422718
PW482718 and PW542718
All pro wall chimney hoods
PI363418, PI423418 and PI543418
All pro hood liners
Duct Size
10" (254) Round
Electrical Rating
5.7 amps at 120 V AC, 60 Hz
Shipping Weight
32 lbs (15 kg)
Static Pressure (in-wg)
0.9
0.8
High
0.7
0.6
0.5
0.4
Med
0.3
0.2
Low
0.1
0
0
100
200
300
400
500
600
Airflow Rate (CFM)
700
800
900
1000
Airflow rate with 30" (762) downdraft.
100'
50'
Downdraft Only
1.1
Calculated for Rigid
10" Galvanized Duct
1.0
Static Pressure (in-wg)
0.9
20 3/4"
(527)
28 1/4"
(718)
10" (254)
DIAMETER
15 1/2"
24 1/2"
(394)
0.8
0.7
0.6
0.5
High
0.4
0.3
Low
0.2
(622)
0.1
0
0
100
200
300
14"
(356)
400
500
600
Airflow Rate (CFM)
700
800
900
1000
900
1000
Airflow rate with 36" (914) downdraft.
4 3/4"
24 3/4"
Med
(121)
(629)
Static Pressure (in-wg)
900 CFM remote blower.
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
100'
75'
50'
25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
100
200
300
400
500
600
Airflow Rate (CFM)
700
800
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
Wolf Blower Specifications
53
wolfappliance.com/specs
Remote Blower Specifications
900 CFM REMOTE BLOWER
1.1
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
1.0
Static Pressure (in-wg)
0.9
100'
Calculated for Rigid
10" Galvanized Duct
0.8
0.7
75'
50'
0.6
25'
0.5
Hood Only
0.4
High
0.3
Med
0.2
0.1
0
Low
0
100
200
300
400
500
600
Airflow Rate (CFM)
700
800
900
1000
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
100'
1.1
75'
1.0
50'
25'
Static Pressure (in-wg)
0.9
Hood Only
Calculated for Rigid
10" Galvanized Duct
0.8
0.7
0.6
0.5
0.4
High
0.3
Med
0.2
Low
0.1
0
0
100
200
300
400
500
600
Airflow Rate (CFM)
700
800
900
1000
900
1000
Airflow rate with pro island hoods.
100'
75'
50'
25'
Hood Only
1.1
1.0
Static Pressure (in-wg)
0.9
Calculated for Rigid
10" Galvanized Duct
0.8
0.7
0.6
0.5
High
0.4
0.3
Med
0.2
Low
0.1
0
0
100
200
300
400
500
600
Airflow Rate (CFM)
Airflow rate with pro hood liners.
700
800
Wolf Blower Specifications
54
Remote Blower Specifications
1200 CFM REMOTE BLOWER
100'
Specifications
291/2"
Dimensions (W x H x D)
18" (457) x
Cooktop Hoods
CTWH30, CTWH36 and IH4227
(749) x 10" (254)
Downdrafts
DD30R, DD36R and DD45R
Pro Hoods
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
Duct Size
10" (254) Round
Electrical Rating
3.0 amps at 120 V AC, 60 Hz
Shipping Weight
38 lbs (17 kg)
Static Pressure (in-wg)
801642
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
50'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
Airflow Rate (CFM)
Airflow rate with 30" (762) downdraft.
(
)
100'
10"
(254)
29 1/2"
(749)
10" (254)
DIAMETER
14 3/4"
29 1/2"
(375)
(749)
Static Pressure (in-wg)
18" (457)
10 1/8"
(257)
22"
(559)
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
7 1/4"
(184)
50'
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
Airflow Rate (CFM)
Airflow rate with 36" (914) downdraft.
A
1200 CFM remote blower.
100'
75' 50' 25'
Hood Only
1.2
Calculated for Rigid
10" Galvanized Duct
1.1
Static Pressure (in-wg)
1.0
0.9
High
0.8
0.7
0.6
0.5
0.4
0.3
Med
0.2
0.1
0
Low
0
200
400
600
800
Airflow Rate (CFM)
1000
1200
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
1400
Wolf Blower Specifications
55
wolfappliance.com/specs
Remote Blower Specifications
1200 CFM REMOTE BLOWER
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
1.2
Calculated for Rigid
10" Galvanized Duct
1.1
Static Pressure (in-wg)
1.0
100'
50'
75'
25'
0.9
0.8
Hood Only
0.7
0.6
Med
0.5
High
0.4
0.3
Low
0.2
0.1
0
0
200
400
600
800
Airflow Rate (CFM)
1000
1200
1400
Static Pressure (in-wg)
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
100'
75'
Calculated for Rigid
10" Galvanized Duct
50'
25'
Hood Only
High
Med
Low
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
Airflow Rate (CFM)
Airflow rate with pro island hoods.
Static Pressure (in-wg)
100'
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
75' 50' 25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
100 200 300 400 500 600 700 800 900 1000 1100 1200 1300
Airflow Rate (CFM)
Airflow rate with pro hood liners.
Wolf Blower Specifications
56
Remote Blower Specifications
1500 CFM REMOTE BLOWER
100'
Specifications
Dimensions (W x H x D)
21" (533) x 291/2" (749) x 10" (254)
Cooktop Hoods
CTWH30, CTWH36 and IH4227
Downdrafts
DD30R, DD36R and DD45R
Pro Hoods
All pro 24" deep wall hoods
All pro 27" deep wall hoods
All pro wall chimney hoods
All pro island hoods
All pro hood liners
Duct Size
10" (254) Round
Electrical Rating
4.3 amps at 120 V AC, 60 Hz
Shipping Weight
45 lbs (20 kg)
Static Pressure (in-wg)
804701
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
75'
50'
25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
1200
1400
1600
Airflow rate with cooktop hoods.
100'
10"
(254)
29 1/2"
(749)
10" (254)
DIAMETER
14 3/4"
29 1/2"
(375)
(749)
Static Pressure (in-wg)
21" (533)
10 3/8"
(264)
25"
7 1/4"
(635)
(184)
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
50'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
1200
1400
1600
Airflow rate with 36" (914) downdraft.
1500 CFM remote blower.
Static Pressure (in-wg)
100'
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
75' 50' 25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
1200
1400
Airflow rate with 30" (762) to 42" (1067) pro wall hoods.
1600
Wolf Blower Specifications
57
wolfappliance.com/specs
Remote Blower Specifications
Static Pressure (in-wg)
1500 CFM REMOTE BLOWER
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
100'
NOTE: Airflow rates for blowers are approximate. A qualified HVAC
professional should make actual system calculations.
75'
Calculated for Rigid
10" Galvanized Duct
Hood Only
50'
25'
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
1200
1400
1600
Airflow rate with 48" (1219) to 66" (1676) pro wall hoods.
Static Pressure (in-wg)
100'
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
75'
50'
25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
1200
1400
1600
Airflow rate with pro island hoods.
Static Pressure (in-wg)
100'
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
75' 50' 25'
Hood Only
Calculated for Rigid
10" Galvanized Duct
High
Med
Low
0
200
400
600
800
1000
Airflow Rate (CFM)
Airflow rate with pro hood liners.
1200
1400
1600
Wolf Blower Specifications
58
In-Line Blower Installation
600 CFM IN-LINE BLOWER
Ductwork options are provided in the illustrations below
for installation of the 600 CFM in-line blower with
horizontal or vertical discharge. Refer to installation
instructions shipped with the in-line blower for detailed
specifications.
Choose the mounting option for the 600 CFM in-line
blower that best suits your installation.
A) Mounting brackets in factory-shipped position.
Discharge parallel to joists.
B) Mounting brackets flipped over and mounted to discharge sides of housing. Discharge parallel to joists.
C) Mounting brackets mounted to discharge sides of
housing. Discharge perpendicular to joists.
ROOF CAP
41/2" (114) x 181/2" (470)
TO 10" (254)
E) Mounting brackets mounted to top of sides of housing.
Discharge parallel to joists.
10" (254)
ROUND
DUCT
ROUND TRANSITION
WALL CAP
10" (254)
ROUND DUCT
D) Mounting brackets flipped over to give approximately
1" (25) more clearance. Discharge parallel to joists.
F) Mounting brackets flipped over and mounted to top of
sides of housing. Discharge parallel to joists.
ELBOW
11/8"
11/2" (38) TO 21/2"
(29)
MAX
Horizontal discharge.
A
211/2" (546)
(64)
D
211/2" (546)
ROOF CAP
41/2" (114) x 181/2" (470)
TO 10" (254)
ROUND TRANSITION
91/2" (241) TO 101/2" (267)
11/2" (38) TO 21/2"
(64)
10" (254)
ROUND
DUCT
B
211/2" (546)
E
211/2" (546)
10 3/4" (273) TO 11 3/4" (298)
10" (254)
ROUND DUCT
Vertical discharge.
C
121/4" (311)
Mounting options.
F
211/2" (546)
Wolf Blower Specifications
59
wolfappliance.com/specs
In-Line Blower Installation
1100 CFM IN-LINE BLOWER
Ductwork options are provided in the illustrations below
for installation of the 1100 CFM in-line blower with
horizontal or vertical discharge. Refer to installation
instructions shipped with the in-line blower for detailed
specifications.
Choose the mounting option for the 1100 CFM in-line
blower that best suits your installation.
A) Mounting brackets in factory-shipped position,
mounted directly to joists. Discharge parallel to joists.
B) Mounting brackets flipped over and mounted to
additional framing. Discharge perpendicular to joists.
C) Mounting brackets flipped over and mounted to
additional framing. Discharge vertical.
ROOF CAP
8" (203) x 12" (305)
TO 10" (254)
10" (254)
ROUND TRANSITIONS
D) Mounting brackets flipped over and mounted to top
of housing. Housing secured with cables. Discharge
parallel to joists.
ROUND
DUCT
WALL CAP
10" (254)
ROUND DUCT
ELBOW
STRAIGHTTHROUGH
DISCHARGE
11/8"
STRAIGHTTHROUGH
DISCHARGE
Horizontal discharge.
(29)
MAX
22" (559)
C
18" (457)
ROOF CAP
ROUND TRANSITIONS
10" (254)
RIGHT-ANGLE
DISCHARGE
ROUND
DUCT
11/2"
(38)
TO
STRAIGHTTHROUGH
DISCHARGE
21/2"
(64)
B
18" (457)
10" (254)
ROUND DUCT
Mounting options.
Vertical discharge.
(38)
TO
21/2"
(64)
A
8" (203) x 12" (305)
TO 10" (254)
11/2"
22" (559)
D
Wolf Blower Specifications
60
Remote Blower Installation
600 AND 900 CFM REMOTE BLOWERS
(216)
REMOVE
SHINGLES
103/8"
(264)
11" (279)
DIAMETER
ROOF RAFTER
If the remote blower is to be installed on a flat roof, a curb
will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
203/4" (527)
81/2"
ROOF RAFTER
Cut-out dimensions are provided in the illustrations for
installation of the 600 CFM or 900 CFM remote blower on
the roof or an exterior wall. Refer to installation instructions
shipped with the remote blower for detailed specifications.
PILOT
HOLE
11/4" (32)
DIAMETER
2"
201/2"
(521)
91/8"
(232)
71/4"
(51)
(184)
291/2"
EXTERIOR ROOF VIEW
(749)
Roof installation.
7"
(178)
25"
2"
(635)
(51)
243/4" (629)
103/4"
(273)
Curb for flat roof.
(327)
REMOVE
SIDING
(216)
11" (279)
DIAMETER
PILOT
HOLE
11/4" (32)
DIAMETER
71/4"
(184)
EXTERIOR WALL VIEW
Exterior wall installation.
WALL STUD
127/8"
WALL STUD
81/2"
281/4"
91/8"
(232)
(718)
Wolf Blower Specifications
61
wolfappliance.com/specs
Remote Blower Installation
1200 CFM REMOTE BLOWER
15" (381)
11/4" (32) DIAMETER
If the remote blower is to be installed on a flat roof, a curb
will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
REMOVE SHINGLES
1"
(25)
ROOF RAFTER
1211/16"
(322)
ROOF RAFTER
Cut-out dimensions are provided in the illustrations for
installation of the 1200 CFM remote blower on the roof or
an exterior wall. Refer to installation instructions shipped
with the remote blower for detailed specifications.
PILOT HOLE
(CENTERED
BETWEEN
RAFTERS)
201/2"
(521)
11" (279)
DIAMETER
913/16"
2"
(249)
(51)
18" (457)
291/2"
EXTERIOR ROOF VIEW
(749)
Roof installation.
7"
(178)
(559)
(51)
Curb for flat roof.
17" (431)
1411/16"
(373)
PILOT HOLE
(CENTERED
BETWEEN
STUDS)
REMOVE
SIDING
11/4" (32)
DIAMETER
3"
(76)
WALL STUD
2"
WALL STUD
22"
11" (279)
DIAMETER
1113/16"
(300)
22" (559)
EXTERIOR WALL VIEW
Exterior wall installation.
291/2"
(749)
Wolf Blower Specifications
62
Remote Blower Installation
1500 CFM REMOTE BLOWER
18" (457)
11/4" (32) DIAMETER
REMOVE SHINGLES
1211/16"
If the remote blower is to be installed on a flat roof, a curb
will have to be constructed for a proper fit. Follow dimensions shown in the illustration below.
1"
(25)
PILOT HOLE
(CENTERED
BETWEEN
RAFTERS)
ROOF RAFTER
(322)
ROOF RAFTER
Cut-out dimensions are provided in the illustrations for
installation of the 1500 CFM remote blower on the roof or
an exterior wall. Refer to installation instructions shipped
with the remote blower for detailed specifications.
201/2"
(521)
11" (279)
DIAMETER
12 5/8"
2"
(321)
(51)
21" (533)
291/2"
EXTERIOR ROOF VIEW
(749)
Roof installation.
7"
(178)
2"
(559)
(51)
20" (508)
Curb for flat roof.
1411/16"
WALL STUD
(373)
11/4" (32)
PILOT HOLE DIAMETER
(CENTERED
BETWEEN
STUDS)
11" (279)
DIAMETER
REMOVE
SIDING
145/8"
(371)
25" (635)
EXTERIOR WALL VIEW
Exterior wall installation.
3"
(76)
WALL STUD
22"
291/2"
(749)
Wolf Ventilation FAQ
63
wolfappliance.com/specs
Frequently Asked Questions
HOW TO DETERMINE WHICH TYPE OF BLOWER TO USE?
HOW CAN THE DUCT RUN BE MOST EFFICIENT?
Many factors can influence the decision between using an
internal, in-line or remote blower. The CFM (based on the
cooking appliance output), length of the duct run and
space available to mount the blower are primary considerations.
For maximum performance keep the duct run straight
and short, with a limited number of elbows and transitions.
45° elbows are more efficient than 90° elbows. Be sure to
use an external roof or wall cap. Wolf ventilation products
will operate most efficiently when ductwork does not
exceed 50' (15 m) in length.
Internal blowers are mounted inside the hood or downdraft. In-line blowers are mounted between the hood and
the exterior of the home. Remote blowers can be mounted
on the roof or, in some cases, on an exterior wall.
HOW CAN BLOWER NOISE BE MINIMIZED?
Some blower noise is considered normal while the blower
is operating. If noise is a concern, a remote blower is
recommended. Using a remote blower will minimize the
amount of blower noise but will not eliminate the noise
completely. Where the remote blower is installed on the
home will also affect the amount of noise. To reduce noise
further for remote blower applications, an attenuator may
be necessary. An attenuator is an electronic device that is
effectively the opposite of an amplifier. While an amplifier
provides gain, an attenuator provides loss in sound level.
WHAT IS MAKE-UP AIR?
When a ventilation hood or downdraft is operating, it
draws air from inside the house to the outside, creating a
slight vacuum within the house. This creates negative
pressure (pressure inside the house is less than the
pressure outside). If the negative pressure is strong
enough, it can cause the furnace and other fuel-burning
appliances to backdraft dangerous gases such as carbon
monoxide into the home. All exhaust fans need an
adequate supply of fresh air from the outside to operate
safely. The air needed for this purpose is called “make-up
air.” Check with a local HVAC professional to determine if
your heating or air conditioning system makes allowances
for additional make-up air. Make-up air can be introduced
by simply opening a window or door.
WHAT TYPE OF DUCTING IS RECOMMENDED?
Wolf hoods and downdrafts should be vented using
smooth, rigid metal ducting. The ridges found in flexible
metal ducting create turbulence and will diminish airflow.
The larger the ducting, the less noise there will be and the
better the rate of airflow.
The information and images in this guide are the copyright property of Wolf Appliance, Inc. Neither this guide nor any information or images contained herein
may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc. ©Wolf Appliance, Inc. all rights reserved.
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc.
Sub-Zero, Sub-Zero & Design, Dual Refrigeration, Constant Care and The Living Kitchen are registered trademarks and service marks of Sub-Zero, Inc.
(collectively, the “Company Marks.”) All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
Wolf Appliance Products Limited Warranty
FOR RESIDENTIAL USE ONLY
FULL TWO YEAR WARRANTY*
For two years from the date of original installation, your Wolf Appliance product warranty covers all parts and
labor to repair or replace, under normal residential use, any part of the product that proves to be defective in
materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be
provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
For five years from the date of original installation, Wolf Appliance will repair or replace the following parts that
prove to be defective in materials or workmanship: gas burners (excluding appearance), electric heating
elements, blower motors (ventilation hoods), electronic control boards, magnetron tubes and induction
generators. The part(s) will be repaired or replaced, free of charge, with the owner paying for all other costs
including labor. All service provided by Wolf Appliance under the above warranty must be performed by Wolf
factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be provided during
normal business hours.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to products
installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of
Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident
or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE,
INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION
OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER
EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have
other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf
Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website,
wolfappliance.com or call 800-222-7820.
*Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day
parts and labor warranty for cosmetic defects.
*Replacement filters for ventilation hood recirculating kits are not covered by the product warranty.
Wolf Appliance Outdoor Products Limited Warranty
PRODUCT MUST BE APPROVED FOR OUTDOOR USE, DESIGNATED BY MODEL AND SERIAL NUMBER
FOR RESIDENTIAL USE ONLY
FULL ONE YEAR WARRANTY*
For one year from the date of original installation, your Wolf Appliance product warranty covers all parts and
labor to repair or replace, under normal residential use, any part of the product that proves to be defective in
materials or workmanship. All service provided by Wolf Appliance under the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf Appliance, Inc. Service will be
provided during normal business hours.
LIMITED FIVE YEAR WARRANTY
Wolf Appliance warrants the stainless steel briquette trays, gas valves, drip pans, electronic control boards and
electric heating elements to be free from defects in materials and workmanship under normal residential use
for a period of five years from the date of original installation. The part(s) will be repaired or replaced, free of
charge, with the owner paying for all other costs including labor. All service provided by Wolf Appliance under
the above warranty must be performed by Wolf factory certified service, unless otherwise specified by Wolf
Appliance, Inc. Service will be provided during normal business hours.
LIMITED LIFETIME WARRANTY
For the life of the product, Wolf Appliance will repair or replace any stainless steel part including all fabricated
stainless steel components, stainless steel burners and grates (excluding what is covered in the Limited Five
Year Warranty) to be defective from workmanship and when subjected to normal domestic use and service. This
warranty excludes surface corrosion, scratches, discoloration, weather and atmospheric related staining, and
minor surface rust and oxidation which are normal conditions. Labor to remove and replace defective parts is
not covered. All service provided by Wolf Appliance under the above warranty must be performed by Wolf
factory certified service, unless otherwise specified by Wolf Appliance, Inc.
TERMS APPLICABLE TO EACH WARRANTY
The warranty applies only to products installed for normal residential use. The warranty applies only to products
installed in any one of the fifty states of the United States, the District of Columbia or the ten provinces of
Canada. This warranty does not cover any parts or labor to correct any defect caused by negligence, accident
or improper use, maintenance, installation, service or repair.
THE REMEDIES DESCRIBED ABOVE FOR EACH WARRANTY ARE THE ONLY ONES THAT WOLF APPLIANCE,
INC. WILL PROVIDE, EITHER UNDER THIS WARRANTY OR UNDER ANY WARRANTY ARISING BY OPERATION
OF LAW. WOLF APPLIANCE, INC. WILL NOT BE RESPONSIBLE FOR ANY CONSEQUENTIAL OR INCIDENTAL
DAMAGES ARISING FROM THE BREACH OF THIS WARRANTY OR ANY OTHER WARRANTY, WHETHER
EXPRESS, IMPLIED OR STATUTORY.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have
other legal rights that vary from state to state.
To receive parts and/or service and the name of Wolf factory certified service nearest you, contact Wolf
Appliance, Inc., P. O. Box 44848, Madison, WI 53744; check the contact & support section of our website,
wolfappliance.com or call 800-222-7820.
*Stainless steel doors, panels, handles, product frames and interior surfaces are covered by a limited 60-day
parts and labor warranty for cosmetic defects.
WOLF APPLIANCE, INC.
P. O. BOX 44848
WVG
MADISON, WI 53744
6 / 2012
WOLFAPPLIANCE.COM
800.222.7820