product - PT Voksel Electric Tbk.

Transcription

product - PT Voksel Electric Tbk.
PRODUCT
CATALOGUE
INTRODUCTION
In the era of global telecommunication,we come to rely
For Various purpose and conditions, the optical fiber
on light again as communication media. Optical fiber
cables and designed fr buried in the ground and duct,
cable which opto-electronic is applied is a means of
hung in air and laid down in the ocean.
transmitting in optical communication system.
This tinny thun glass fiber of approximately 10 mm in
Product Quality is Our Concern
diameter could carry more information across longer
PT Voksel Electric Tbk commited product quality to be
distance than well-known metallic copper cable. For
special purpose, a very long distance could be covered
with optical fibers without any repeater.
the primary manner of its all facets of the company,
Optical parameter is tested fr all optical fiber cables
covering incoming material, intermediate inspection
The glass fiber consists of core and jacket which are
and final inspection by applying a high quality testing
made from very high grade pure silicon dioxide. Subject
equipment and operated by well-trained operators
to this benefit, he fiber tensile strength s string and the
in order t meet costumer’s requirement and our
liht iwl be dopped to provide specific internal refreactive
commitment to ISO 9000 series of Quality Management
index.
System.
Optical fiber cable become more popular also in
the subscriber network due to dynamic demand of
communication. They are not applicable only for
telephone, fax, acd television but hight speed computer
data will be as well transferred over data highways
across the entire universe.
PT. Voksel Electric Tbk, headquartered in Jakarta,
is one of the indonesia’s premier manufacturer
of the cables used by the power generation and
telecommunication industries. Since 1975 Voksel
benefited from an early alliance formed with Showa
Electric, Wire & Cable Co.Ltd. of Japan, through which
Voksel had technical assistance, as well, as support
and aluminium wire rod essential for its production
fr it wn Researh and Development effrts. For futher
of cables. Voksel commited to be the leading edge of
development, since 1989, that relationship became a
Technology in yhe manufacturing and design of a wide
joint venture company.
variety of the cables.
To take advantage of new marketing oppurtunities
In present, Voksel has developed his product range by
and to maintain its competitive edge in a fast-growing
manufacturing and designing optical fiber cables.
industrial sector. Voksel has vertically intergrated its
operations.
In recognition of the quality management standards
in place of its manufacturing plants at Cakung (North
The company manufacturers enameled wire, low
Jakarta) and cileungsi (West Java). PT. Voksel Electric
voltage and medium voltage power cables and
Tbk, was awarded ISO 9002 certification by SGS. Yarsley
telecommunication cables. It also manufactures copper
International Certification Service Ltd. In 1995.
ADVANTAGES OF OPTICAL FIBER
Small Diameter
Space Efficiency
Light Weight
Easy Multi – fiber
Cabling
Flexible
Easy Installation
Noise Immunity
Low Cross-Talk
Long Repeater
Span
Low Loss
Large Capacity
Transmission Line
Wide Bandwidth
Long Haul &
Regional Network
Metropolitan Network
Local Access Network
Cell
Site
CATV
Premise Network
OPTICAL FIBER CABLE
THE CHARACTERISTIC OF OPTICAL FIBER CABLE
The number of fiber in a cable varies from 4 to 264 (more number of fibers are provided upon request). Optical fiber cables
will generally undergo 4 processes of production line such as Coloring Line, secondary Coating Line, SZ- stranding Line and
Sheathing Line.
• Coloring Production Line:
• SZ- Stranding Production line:
Fiber Coloring Process is carried out to mark the
Stranding process which is around polyethelene
fiber. For easy identification of individual fiber inside
coated central strength member applies SZ-
the tubes, they are color coded. The colors have no
Stranding Method. The stranding is filled with jelly as
influence on the optical properties of the fibers. The
Flooding Compound to fill any space of the cable to
fiber are colored using UV ink which are chosen as
block the flow of water into the cable.
industry standard, easily in stripping, jointing and
• Sheathing Production Line:
stability of optical loss under various stress.
• Secondary Coating Production Line:
Blue
Orange
3
Green
3
Green
4
Brown
4
Brown
5
Grey
5
Grey
6
White
6
White
7
Red
7
Red
8
Black
8
Black
9
Yellow
9
Yellow
10
Violet
10
Violet
11
Pink
the optical cable core from mechanical, thermal
Turquoise
contain fibers and are filled with special typical
(LAP) sheath containing carbon black, to provide an
gel. Secondary coating or tubing process is used
electrical ground and moisture barrier. Sheathing also
to protect the optical fibers during cabling and
uses one corrugated steel tape between inner and
installation process.
outer sheath to provide a mechanical protectin. The
sheath is usually over printed t identify the type of
cable of a particular point.
BASIC CABLE
DESIGN
1
2
3
6 Fibers per Tube
1. PBTP Tube
0.008-0.010 mm
2. Filling Gel
Table 1. Color Scheme of Optical Fibers
Table 2. Color Scheme of PBTP Tubes
Table 3. Optical Characteristic of G.652D, G655C, G657A
Characteristic
Value
Unit
Fiber Type
Single Mode
-
Mode Field Dia. At 1310 nm
9 to 10 ± 10%
µm
Mode Field Concentricity Error
<1
µm
Cladding Diameter
125 ± 2
µm
Cladding non Circularity
<2
%
Coating Diameter
250 ± 15
µm
Maximum Attenuation at 1310 nm
0.4
dB/km
Maximum Attenuation at 1550 nm
0.3
dB/km
Maximum Chromatic dispersion at 1310 nm
3.5
Ps/(nm.Km)
Maximum Chromatic dispersion at 1550 nm
18
Ps/(nm.Km)
Min. Bending Radius at full Tensile Strength
20 x cable OD
-
Maximum Cut Off Wavelength at 1310 nm (λcc)
1260
nm
Zero Dispersion Wavelength (λo)
1300 – 1324
nm
Zero Dispersion Slope (So)
≤ 0.095
Ps/(nm2.Km)
Value
Unit
3. Colored Fiber
0.125 mm
Each fiber is made of high purity Silica
(SiO2) Glass doped with Germanium
(GeO2) and fuse (SiO2) depressed
cladding design for excellent geometrical
properties for splicing and micro bending
resistance. This fiber core is protected by
two layers of UV-cured acrylate coating
which is strong and durable enough to
stand up to the challenge such as; micro
bending losses, abrasion resistance, etc
but remain easy to strip and splice.
1
2
12
covered with laminated Aluminium Polyethelene
0.250 mm
Blue
Orange
Pink
hydrolysis and mechanical properties. The tubes
4 Fibers per Tube
1
2
Turquoise
installation and operation. The core covering is
Cladding
(SiO2)
Color of Tube
11
as tube material which extremely has goos thermal,
Cladding
(Acrylate)
Tube No.
12
and chemical effects, associated with storage,
Core
(SiO2 + GeO2)
Color of Fiber
Sheathing line is an unit which its process protects
This process uses Polybutylene Terepthalate (PBTP)
OPTICAL FIBER
DESIGN
Optical Fiber No.
12 Fibers per Tube
1 Fiber per Tube
The cable core consists of stranded - six
or eight thermal plastic elements with
a central strength member . Elements
could be either tubes, filler rods.
The coloured Polybutylene Teprepthalate
(PBTP) tube contains 4,6, or 12 coloured
fibers with its configuration (table 1
and 2) and water blocking compound to
prevent moisture/water penetration and
axial migration.
Now, There is cable core consists of
stranded - twelve thermal plastic
elements with a central strength
member . Elements could be either
tubes , filler rods, and Polybutylene
Teprepthalate (PBTP) tube contains 1
fibers.
Table 4. Environment condition
Item
Operating Temperature
10 - 50
ºC
Operating Relative Humidity
20 - 100
%
Storage Tempertature
10 – 70
ºC
Storage Relative Humidity
20-95
%
OPTICAL FIBER CABLE
ADSS TYPE
TYPICAL SPECIFICATION
Number of Fiber
Item
This is optical cable ADSS type (All
Dielectric Self Supporting) with Aramid
Yarn for peripheral strength member.
This cable must have non-metalic and
high tensile strength. They are used
as Aerial Application, anti rodent, anti
ballistic, anti termite cable whenever
mechanical strength, anti electrical
induction and lighting effect.
For Aerial Installation,
Dry Core Technology
(All Dielectric Self Supporting)
Fiber Type
Cable Size
G652 A ~ D
G653 A & B
G654 A ~ C
G655 A ~ E
6 - 36
24 - 72
60 – 96
6
6
6
8
Loose Tube Number
4
6
12
12
Max.Tube OD (mm)
Fiber Number per Lose Tube
2.2
2.5
3.5
3.5
Max.Cable outer Diameter (mm)
13.6
14.5
17.5
19.5
4 ~ 264 Cores
Loose Tube Number
Fiber Count
Standard
4 - 16
ITU-T G Series
IEC 60793/IEC 60794
IEC 60304
IEC 60587
Telecordia GR-20
1
2
3
4
5
6
4
4
Filler
Filler
Filler
Filler
Filler
6
6
Filler
Filler
Filler
Filler
Filler
12
4
4
Filler
Filler
4
Filler
12
6
Filler
Filler
6
Filler
Filler
16
4
4
Filler
4
4
Filler
18
6
6
Filler
Filler
6
Filler
24
6
6
Filler
6
6
Filler
24
12
Filler
Filler
12
Filler
Filler
36
6
6
6
6
6
6
36
12
12
Filler
Filler
12
Filler
48
12
12
Filler
12
12
Filler
60
12
12
12
12
12
Filler
72
12
12
12
12
12
12
Loose Tube Number
Fiber Count
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
1.
2.
3.
4.
5.
HDPE Anti Tracking sheath
Water Blocking Tape
Peripheral strength member (Aramid Yarn)
Filler Rod
Non Metalic Central Strength Member
(GRP + PE coated)
6. Ripcord
7. Water Blocking Yarn
8. Single mode color code optical fiber
9. Gel filed PBTP color coded tube
Number of Fiber
Property
1 - 16
18 - 36
48
60 - 72
Tensile Strength
> 12.000
> 12.000
> 12.000
> 12.000
Crush Resistance
≥2
≥2
≥2
≥2
± 172
± 235
± 240
± 292
Max. Weight
Unit
84-96
> 12.000
N
≥2
KN/100mm
± 298
Kg/km
Min. Bending
mm
Proof Test
> 0.5
%
Filler
4
4
Filler
Additional Loss
< 0.1
dB
Filler
Filler
6
Filler
Radius
30
mm
Filler
6
6
Filler
Number of Turn
100
-
Filler
12
Filler
Filler
Property
Value
Unit
Proof Test
> 0.5
%
Additional Loss
< 0.1
dB
Radius
30
mm
Number of Turn
100
-
OPTICAL FIBER CABLE
FOR AERIAL INSTALLATION
TYPICAL SPECIFICATION
This is optical fiber cable intregated
with a messenger wire for aerial
installation. This cable is loose tube
core. If armouring is necessary to
prevent damage by rodents, insects,
and shot guns, a peripheral high
strength yarn can applied.
Non Metallic
Central Strength
Member
Optical Fiber
Central Strength
Member Jacket
Filler Rod
Loose Tube
Aramid Yarn for Binder
Fiber Type
Water Blocking Tape
Aluminium Tape
Messenger Wire
Aramid Yarn
for Ripcord
Cable Size
Standard
G652 A ~ D
G653 A & B
G654 A ~ C
G655 A ~ E
4 ~ 264 Cores
ITU-T G Series
IEC 60793/IEC 60794
IEC 60304
STEL K-017-2008 ver. 2.0
Outer Sheath
2
3
4
5
6
7
8
9
10
1.
2.
3.
4.
5.
6.
HDPE sheath
Steel wire messenger
Laminated Aluminum Polyethylene type
Water Blocking Tape
Peripheral strength member (Aramid Yarn).
Non Metalic Central Strength Member
(GRP + PE coated)
7. Ripcord
8. Filler Rod
9. Single mode color code optical fiber
10. Gel filed PBTP color coded tube
4 - 16
6 - 36
24 - 72
60 – 96
6
6
6
8
Loose Tubes Number
4
6
12
12
Max.Tube OD (mm)
Fiber Number per Loose Tube
2.2
2.5
3.5
3.5
Max. Cable Outer Diameter (mm)
13.5
17.5
17.5
17.5
Loose Tube Number
Fiber Count
1
2
3
4
5
6
4
4
Filler
Filler
Filler
Filler
Filler
6
6
Filler
Filler
Filler
Filler
Filler
8
4
Filler
Filler
4
Filler
Filler
12
4
4
Filler
Filler
4
Filler
12
6
Filler
Filler
6
Filler
Filler
16
4
4
Filler
4
4
Filler
18
6
6
Filler
Filler
6
Filler
24
6
6
Filler
6
6
Filler
24
12
Filler
Filler
12
Filler
Filler
36
6
6
6
6
6
6
36
12
12
Filler
Filler
12
Filler
48
12
12
Filler
12
12
Filler
60
12
12
12
12
12
Filler
72
12
12
12
12
12
12
Loose Tube Number
Fiber Count
1
Number of Fiber
Item
1
2
3
4
60
12
12
Filler
Filler
12
5
12
6
12
7
Filler
8
72
12
12
12
Filler
12
12
12
Filler
84
12
12
12
12
12
12
12
Filler
96
12
12
12
12
12
12
12
12
Mechanical Characteristic
Number of Fiber
Property
1 - 16
18 - 36
48
60 - 72
Tensile Strength
> 2700
> 2700
> 2700
> 2700
Crush Resistance
≥2
≥2
≥2
≥2
Max. Weight
± 228
± 228
± 228
± 228
Min. Bending
225
270
300
300
Characteristic
Value
Unit
84-96
> 2700
N
≥2
KN/100mm
± 228
Kg/Km
300
mm
Unit
Proof Test
1
%
Additional Loss
< 0.1
dB
Radius
30
mm
Number of Turn
100
-
OPTICAL FIBER FOR
DIRECT BURIED INSTALLATION
This is optical fiber cable a corrugated
steel tape or steel wire armoring for
protection. They are used as direct
buried, anti ballistic, anti rodent, anti
termite cables whenever mechanical
strength is required. This cable is loose
tube core.
For Direct Buried Installation
TYPICAL SPECIFICATION
Fiber Type
G652 A ~ D
G653 A & B
G654 A ~ C
G655 A ~ E
Cable Size
4 ~ 264 Cores
Standard
ITU-T G Series
IEC 60793/IEC 60794
IEC 60304
STEL K-016-2008 ver. 2.0
5
6
7
8
9
10
11
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
HDPE sheath
Corrugated Steel Tape Armor
MDPE inner sheath
Laminated Aluminum Polyethylene type
Non metalic central strength member (GRP+PE coated)
Water Blocking Tape
Ripcord
Peripheral strength member (Aramid Yarn).
Filler Rod
Gel filed PBTP color coded tube
Single mode color code optical fiber
4 - 16
6 - 36
24 - 72
60 – 96
6
6
6
8
Loose Tubes Number
4
6
12
12
Max.Tube OD (mm)
Fiber Number per Loose Tube
2.2
2.5
3.5
3.5
Max. Cable Outer Diameter (mm)
18.2
22.2
22.2
22.2
Loose Tube Number
Fiber Count
1
2
3
4
5
6
4
4
Filler
Filler
Filler
Filler
Filler
6
6
Filler
Filler
Filler
Filler
Filler
12
4
4
Filler
Filler
4
Filler
12
6
Filler
Filler
6
Filler
Filler
16
4
4
Filler
4
4
Filler
18
6
6
Filler
Filler
6
Filler
24
6
6
Filler
6
6
Filler
24
12
Filler
Filler
12
Filler
Filler
36
6
6
6
6
6
6
36
12
12
Filler
Filler
12
Filler
48
12
12
Filler
12
12
Filler
60
12
12
12
12
12
Filler
72
12
12
12
12
12
12
72
12
12
12
12
12
12
Loose Tube Number
Fiber Count
1
2
3
4
Number of Fiber
Item
1
2
3
4
5
6
7
8
60
12
12
Filler
Filler
12
12
12
Filler
72
12
12
12
Filler
12
12
12
Filler
84
12
12
12
12
12
12
12
Filler
96
12
12
12
12
12
12
12
12
Mechanical Characteristic
Number of Fiber
Property
Unit
1 - 16
18 - 36
48
60 - 72
Tensile Strength
> 2700
> 2700
> 2700
> 2700
> 2700
N
Crush Resistance
≥ 4.5
≥ 4.5
≥ 4.5
≥ 4.5
≥ 4.5
KN/100mm
Max. Weight
± 326
± 446
± 467
± 471
± 473
Kg/Km
Min. Bending
≤ 250
≤ 270
≤ 300
≤ 300
≤ 300
mm
Characteristic
Value
84-96
Unit
Proof Test
0.5
%
Additional Loss
< 0.1
dB
Radius
30
mm
Number of Turn
100
-
OPTICAL FIBER CABLE FOR
DROP WIRE INSTALLATION
TYPICAL SPECIFICATION
Type Specification Drop Aerial Cable
Number of Fiber
Item
Drop cable being made to accommodate FTTH system telecommunication
industry as for wiring from terrestrial to Ethernet system. Designed to short
distance span with easy connection from end – user to nearby fiber access
terminal. This cable consist of 1 up to 4 fiber core with to FRP in both inside to
avoid shrieked in its cable jacketing. There are two kinds cable (Aerial and Burial)
1
2
4
Max. Cable Height (mm)
5 – 5.5
5 – 5.5
1.2
Max. Cable Width (mm)
2 - 2.5
2 - 2.5
12.5
Type Specification Single Drop Burial Cable
Number of Fiber
Item
Construction DROP Aerial Cable
1
2
3
1
2
4
Max. Cable Height (mm)
3 - 3.5
3 - 3.5
3 - 3.5
Max. Cable Width (mm)
2 - 2.5
2 - 2.5
12.5
Mechanical Characteristic
Number of Fiber
2012 VOKSEL KABEL OPTIK/G657A /DW 2F
Fiber Count
4
5
1.
2.
3.
4.
5.
Steel Wire Messenger
PBT Loose Tube
Optical Fiber
PE Sheath
GRP Strength Member
Construction DROP burial Cable
2012 VOKSEL KABEL OPTIK/G657A /DW 2F
3
4
1
2
1.
2.
3.
4.
PE Sheath
GRP Strength Member
PBT Loose Tube
Optical Fiber
1
2
4
Unit
Tensile Strength
> 130
> 130
> 130
N
Crush Resistance
≥ 0.3
≥ 0.3
≥ 0.3
kg
Max. Weight
± 10
± 10
± 38
Kg/Km
Min. Bending
20 X OD
20 X OD
20 X OD
Characteristic
Value
mm
Unit
Proof Test
1
%
Additional Loss
< 0.1
dB
Radius
15
mm
OPTICAL FIBER FOR
DUCT INSTALLATION
TYPICAL SPECIFICATION
Number of Fiber
Item
This is optical fiber cable is with loose
tube core. It is quite suitable to the
system requiring more optical fibers.
The fibers are accommodated in jelly
filled tubes with an excess length.
If a flame retardant characteristic is
required, a special material can be
applied as the outer sheath.
For Duct Installation
Fiber Type
Cable Size
Standard
G652 A ~ D
G653 A & B
G654 A ~ C
G655 A ~ E
ITU-T G Series
IEC 60793/IEC 60794
IEC 60304
STEL K-016-2008 ver. 2.0
5
6
7
8
9
10
HDPE sheath
Laminated Aluminum Polyethylene type
Water Blocking Tape
Metalic/non metalic central strength member
Peripheral strength member (Aramid Yarn).
Ripcord
Filler Rod
Flooding compound (Jelly) / non Jelly (dry cable type).
Gel filed PBTP color coded tube
Single mode color code optical fiber
24 - 72
60 – 96
Loose Tubes Number
6
6
6
8
4
6
12
12
Max.Tube OD (mm)
2.2
2.5
3.5
3.5
Max. Cable Outer Diameter (mm)
13.5
17.5
17.5
17.5
4 ~ 264 Cores
1
2
3
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
6 - 36
Fiber Number per Loose Tube
Loose Tube Number
Fiber Count
1
2
3
4
5
6
4
4
Filler
Filler
Filler
Filler
Filler
6
6
Filler
Filler
Filler
Filler
Filler
12
4
4
Filler
Filler
4
Filler
12
6
Filler
Filler
6
Filler
Filler
16
4
4
Filler
4
4
Filler
18
6
6
Filler
Filler
6
Filler
24
6
6
Filler
6
6
Filler
24
12
Filler
Filler
12
Filler
Filler
36
6
6
6
6
6
6
36
12
12
Filler
Filler
12
Filler
48
12
12
Filler
12
12
Filler
60
12
12
12
12
12
Filler
72
12
12
12
12
12
12
72
12
12
12
12
12
12
Loose Tube Number
Fiber Count
4
4 - 16
1
2
3
4
5
6
7
8
60
12
12
Filler
Filler
12
12
12
Filler
72
12
12
12
Filler
12
12
12
Filler
84
12
12
12
12
12
12
12
Filler
96
12
12
12
12
12
12
12
12
Mechanical Characteristic
Number of Fiber
Property
1 - 16
18 - 36
48
60 - 72
Tensile strength
> 2700
> 2700
> 2700
> 2700
Crush Resistance
≥2
≥2
≥2
≥2
Unit
84-96
> 2700
N
≥2
KN/100mm
Max.Weight
± 172
± 273
± 275
± 278
± 281
Kg/Km
Min.Bending
(No Load)
≤ 250
≤ 270
≤ 300
≤ 300
≤ 300
mm
Min.Bending
(Under Load)
≤ 250
≤ 270
≤ 300
≤ 300
≤ 300
mm
Characteristic
Value
Unit
Proof Test
> 0.5
%
Additional Loss
< 0.1
dB
Radius
30
mm
Number of Turn
100
-
OPTICAL FIBER CABLE
FOR AERIAL INSTALLATION
TYPICAL SPECIFICATION
Type Specification Single Core Per Tube Aerial
Number of Fiber
Item
In fiber optic, Single Core Per Tube is one type of cable used to capture one or more
optical fiber for the FTTH (Fiber to The Home) Distribution cable. With design easier
to split the fiber core and connecting to termination box as well as the loose tube
type is compatible in humidly temperature capacity 8 – 24 Core. There are two kind
type cable FTTH (Aerial Application Cable and Duct Application Cable)
Standard
STEL QA – K – 036 –2012
Specification (AERIAL)
STEL QA – K – 037 – 2012
(DUCT)
8
10
12
18
24
Loose Tubes Number
8
10
12
18
8
Fiber Number per Loose Tube
1
1
1
1
1
Max.Tube OD (mm)
1.2
1.2
1.2
1.2
1.2
Max. Cable Outer Diameter (mm)
10.6
11.6
12.5
13.5
15
Type Specification Single Core Per Tube Duct
Construction Single Core Per Tube Aerial Cable
Non Metallic
Central Strength
Member
Optical Fiber
Aramid Yarn for Binder
Loose Tube
Messenger Wire
8
10
12
18
24
Loose Tubes Number
8
10
12
18
8
Fiber Number per Loose Tube
1
1
1
1
1
Max.Tube OD (mm)
1.2
1.2
1.2
1.2
1.2
Max. Cable Outer Diameter (mm)
10.6
11.6
12.5
13.5
15
Central Strength
Member Jacket
Water Blocking Tape
Jumlah Serat Optik
18
Lapis 1
1
1
1
1
1
1
-
Black HDPE Sheath
Filler Rod
Aluminium Tape
VOKSEL 2013 FIBER OPTIC / SM.D / A 24 / 24 T
Messenger Wire
Outer Sheath
Number of Fiber
Item
Aramid Yarn
for Ripcord
Moisture Barrier
Non Laminated Water Blocking Yarn
High Tensile Aramid Yarn
Ripcord Aramid Yarn
High Tensile Aramid Yarn
Loose Tube
Nomor urut serat/ Tube
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Optical Fiber
FRP with PE Coated
Construction Single Core Per Tube DUCT Cable
Black HDPE Sheath
Moisture Barrier
Non Laminated Water Blocking Yarn
High Tensile Aramid Yarn
Ripcord Aramid Yarn
High Tensile Aramid Yarn
Loose Tube
VOKSEL 2013 / FIBER OPTIC / SM.D / D 24 / 24 T
Optical Fiber
FRP with PE Coated
8
Lapis 1
1
1
1
1
1
1
1
1
-
10
Lapis 1
1
1
1
1
1
1
1
1
1
-
12
Lapis 1
1
1
1
1
1
1
1
1
1
1
1
1
-
24
Lapis 2
1
1
1
1
1
1
1
1
1
1
1
1
-
Lapis 1
1
1
1
1
1
1
1
1
1
-
Lapis 2
1
1
1
1
1
1
1
Filler
1
1
1
1
1
1
1
Filler
Mechanical Characteristic
Number of Fiber
Fiber Count
8
10
12
18
Unit
24
Tensile strength
> 2850
> 2850
> 2850
> 2850
> 2850
N
Crush Resistant
≥ 2,2
≥ 2,2
≥ 2,2
≥ 2,2
≥ 2,2
KN/100mm
Max. Weight
± 185
± 200
± 210
± 215
± 240
Kg/Km
Min. Bending
20 X OD
20 X OD
20 X OD
20 X OD
20 X OD
mm
Characteristic
Value
Unit
Proof Test
1
%
Additional Loss
< 0.1
dB
Radius
30
mm
Number of Turn
100
-
JUMPER
WIRE
DROP
WIRE
Poly Vinyl Chloride insulated Jumper
Wires are designed for cross connecting
of jumping usage, on MDF,IDF, and
other connecting circuit in cable house.
Conductor
Diameter
mm
0.6
Cable Size
Pair
1
PVC Insulations
Thickness
mm
0.3
mm
2.4
2 x 1 x 0.5
External
Diameter
STEEL K-006
Cable Weight
SII 0616-82
m
500
SNI 04-2068-1990
Standard Packing
Length
R-V
Drum Volume
m3
-
Type of Product Jumper Wire
Cable Size
Ref. Standard
Cable
Designation
DESCRIPTION
2 x 1 x 0.6
Aerial Drop wires are designed for
installations, from distribution cables
to subcribers or for installations on
external wall of buildings or houses
Jumper Wire Dimensions
kg/km
mm
0.6
0.8
Cable Size
Pair
1
1
mm
1.0
1.0
2 x 1 x 0.6
PE Insulation
Thickness
2 x 1 x 0.8
Cable Width
mm
5.9
5.9
Ref. Standard
8
Suspension
Strand
mm
1/1.2
1/1.2
kg/km
31
36
Standard
Packing Length
m
500
500
Drum Volume
m3
-
-
Coil
Coil
STEEL K-004
SII 064-82
SNI 04-2066-1990
Drum Type
UNIT
Conductor
Diameter
Type of Product Drop Wire
Cable Size
Cable
Designation
Coil
Drop Wire Dimensions
U - ES
Cable Weight
Drum Type
SPECIFICATION
ELECTRICAL AND MECHANICAL DATA :
Conductor resistance at 20 ± 1ºC
Maximum Individual
Min. Insulation resistance at 5000 V DC
DESCRIPTION
Ohm/km
M Ohm.km/minute
65.00
100
MECHANICAL CHARACTERISTICS :
Min. Elongation of copper conductor
Min. Tensile Strength of PVC insulation
Min.Elongation of PVC insulation
%
N/mm²
%
18
12.5
12.5
UNIT
ELECTRICAL AND MECHANICAL DATA :
Conductor resistance at 20 ± 1ºC
Maximum Individual
Min. Insulation resistance at 5000 V DC
Ohm/km
M Ohm.km/minute
65.00
10,000
MECHANICAL CHARACTERISTICS :
%
N/mm²
%
Min. Elongation of copper conductor
Min. Tensile Strength of PVC insulation
Min.Elongation of PVC insulation
Cable Construction
SPECIFICATION
18
1255
300
PVC Insulation
Galvanised Steel Wire
(GSW)
Copper Conductor
PVC Insulation
Installation Colour
Pair Number
Steel Wire
(1 x 1.2 mm)
Single Core
(Copper)
PE Sheath
(Black)
Colour of Insulation
“A” Wire
“B” Wire
1
White
Blue
2
White
Red
3
White
Black
4
Blue
Red
Black PE
Sheath
Single Core
(Copper)
Cable
Marking
Copper Conductor
(2 x 0.6 mm)
PT. VOKSEL ELECTRIC Tbk.
EXECUTIVE OFFICE
Menara Karya 3rd Fl. Suite D Jl. HR. Rasuna Said Block X-5 Kav 1-2 Jakarta 12950 Indonesia
Ph. +62 21 5794 4622 Fx. +62 21 5794 4649
FACTORY & OPERATIONAL
OFFICE
Jl. Raya Narogong Km 16 Cileungsi Bogor 16820 Indonesia
Ph. +62 21 823 0525 +62 21 8249 1720 +62 21 8249 1712 Fx. +62 21 823 0526 +62 21 8249 1701
Hotline: + 62 21 8249 3329 E-mail: [email protected] [email protected]

Similar documents