product - PT Voksel Electric Tbk.
Transcription
product - PT Voksel Electric Tbk.
PRODUCT CATALOGUE INTRODUCTION In the era of global telecommunication,we come to rely For Various purpose and conditions, the optical fiber on light again as communication media. Optical fiber cables and designed fr buried in the ground and duct, cable which opto-electronic is applied is a means of hung in air and laid down in the ocean. transmitting in optical communication system. This tinny thun glass fiber of approximately 10 mm in Product Quality is Our Concern diameter could carry more information across longer PT Voksel Electric Tbk commited product quality to be distance than well-known metallic copper cable. For special purpose, a very long distance could be covered with optical fibers without any repeater. the primary manner of its all facets of the company, Optical parameter is tested fr all optical fiber cables covering incoming material, intermediate inspection The glass fiber consists of core and jacket which are and final inspection by applying a high quality testing made from very high grade pure silicon dioxide. Subject equipment and operated by well-trained operators to this benefit, he fiber tensile strength s string and the in order t meet costumer’s requirement and our liht iwl be dopped to provide specific internal refreactive commitment to ISO 9000 series of Quality Management index. System. Optical fiber cable become more popular also in the subscriber network due to dynamic demand of communication. They are not applicable only for telephone, fax, acd television but hight speed computer data will be as well transferred over data highways across the entire universe. PT. Voksel Electric Tbk, headquartered in Jakarta, is one of the indonesia’s premier manufacturer of the cables used by the power generation and telecommunication industries. Since 1975 Voksel benefited from an early alliance formed with Showa Electric, Wire & Cable Co.Ltd. of Japan, through which Voksel had technical assistance, as well, as support and aluminium wire rod essential for its production fr it wn Researh and Development effrts. For futher of cables. Voksel commited to be the leading edge of development, since 1989, that relationship became a Technology in yhe manufacturing and design of a wide joint venture company. variety of the cables. To take advantage of new marketing oppurtunities In present, Voksel has developed his product range by and to maintain its competitive edge in a fast-growing manufacturing and designing optical fiber cables. industrial sector. Voksel has vertically intergrated its operations. In recognition of the quality management standards in place of its manufacturing plants at Cakung (North The company manufacturers enameled wire, low Jakarta) and cileungsi (West Java). PT. Voksel Electric voltage and medium voltage power cables and Tbk, was awarded ISO 9002 certification by SGS. Yarsley telecommunication cables. It also manufactures copper International Certification Service Ltd. In 1995. ADVANTAGES OF OPTICAL FIBER Small Diameter Space Efficiency Light Weight Easy Multi – fiber Cabling Flexible Easy Installation Noise Immunity Low Cross-Talk Long Repeater Span Low Loss Large Capacity Transmission Line Wide Bandwidth Long Haul & Regional Network Metropolitan Network Local Access Network Cell Site CATV Premise Network OPTICAL FIBER CABLE THE CHARACTERISTIC OF OPTICAL FIBER CABLE The number of fiber in a cable varies from 4 to 264 (more number of fibers are provided upon request). Optical fiber cables will generally undergo 4 processes of production line such as Coloring Line, secondary Coating Line, SZ- stranding Line and Sheathing Line. • Coloring Production Line: • SZ- Stranding Production line: Fiber Coloring Process is carried out to mark the Stranding process which is around polyethelene fiber. For easy identification of individual fiber inside coated central strength member applies SZ- the tubes, they are color coded. The colors have no Stranding Method. The stranding is filled with jelly as influence on the optical properties of the fibers. The Flooding Compound to fill any space of the cable to fiber are colored using UV ink which are chosen as block the flow of water into the cable. industry standard, easily in stripping, jointing and • Sheathing Production Line: stability of optical loss under various stress. • Secondary Coating Production Line: Blue Orange 3 Green 3 Green 4 Brown 4 Brown 5 Grey 5 Grey 6 White 6 White 7 Red 7 Red 8 Black 8 Black 9 Yellow 9 Yellow 10 Violet 10 Violet 11 Pink the optical cable core from mechanical, thermal Turquoise contain fibers and are filled with special typical (LAP) sheath containing carbon black, to provide an gel. Secondary coating or tubing process is used electrical ground and moisture barrier. Sheathing also to protect the optical fibers during cabling and uses one corrugated steel tape between inner and installation process. outer sheath to provide a mechanical protectin. The sheath is usually over printed t identify the type of cable of a particular point. BASIC CABLE DESIGN 1 2 3 6 Fibers per Tube 1. PBTP Tube 0.008-0.010 mm 2. Filling Gel Table 1. Color Scheme of Optical Fibers Table 2. Color Scheme of PBTP Tubes Table 3. Optical Characteristic of G.652D, G655C, G657A Characteristic Value Unit Fiber Type Single Mode - Mode Field Dia. At 1310 nm 9 to 10 ± 10% µm Mode Field Concentricity Error <1 µm Cladding Diameter 125 ± 2 µm Cladding non Circularity <2 % Coating Diameter 250 ± 15 µm Maximum Attenuation at 1310 nm 0.4 dB/km Maximum Attenuation at 1550 nm 0.3 dB/km Maximum Chromatic dispersion at 1310 nm 3.5 Ps/(nm.Km) Maximum Chromatic dispersion at 1550 nm 18 Ps/(nm.Km) Min. Bending Radius at full Tensile Strength 20 x cable OD - Maximum Cut Off Wavelength at 1310 nm (λcc) 1260 nm Zero Dispersion Wavelength (λo) 1300 – 1324 nm Zero Dispersion Slope (So) ≤ 0.095 Ps/(nm2.Km) Value Unit 3. Colored Fiber 0.125 mm Each fiber is made of high purity Silica (SiO2) Glass doped with Germanium (GeO2) and fuse (SiO2) depressed cladding design for excellent geometrical properties for splicing and micro bending resistance. This fiber core is protected by two layers of UV-cured acrylate coating which is strong and durable enough to stand up to the challenge such as; micro bending losses, abrasion resistance, etc but remain easy to strip and splice. 1 2 12 covered with laminated Aluminium Polyethelene 0.250 mm Blue Orange Pink hydrolysis and mechanical properties. The tubes 4 Fibers per Tube 1 2 Turquoise installation and operation. The core covering is Cladding (SiO2) Color of Tube 11 as tube material which extremely has goos thermal, Cladding (Acrylate) Tube No. 12 and chemical effects, associated with storage, Core (SiO2 + GeO2) Color of Fiber Sheathing line is an unit which its process protects This process uses Polybutylene Terepthalate (PBTP) OPTICAL FIBER DESIGN Optical Fiber No. 12 Fibers per Tube 1 Fiber per Tube The cable core consists of stranded - six or eight thermal plastic elements with a central strength member . Elements could be either tubes, filler rods. The coloured Polybutylene Teprepthalate (PBTP) tube contains 4,6, or 12 coloured fibers with its configuration (table 1 and 2) and water blocking compound to prevent moisture/water penetration and axial migration. Now, There is cable core consists of stranded - twelve thermal plastic elements with a central strength member . Elements could be either tubes , filler rods, and Polybutylene Teprepthalate (PBTP) tube contains 1 fibers. Table 4. Environment condition Item Operating Temperature 10 - 50 ºC Operating Relative Humidity 20 - 100 % Storage Tempertature 10 – 70 ºC Storage Relative Humidity 20-95 % OPTICAL FIBER CABLE ADSS TYPE TYPICAL SPECIFICATION Number of Fiber Item This is optical cable ADSS type (All Dielectric Self Supporting) with Aramid Yarn for peripheral strength member. This cable must have non-metalic and high tensile strength. They are used as Aerial Application, anti rodent, anti ballistic, anti termite cable whenever mechanical strength, anti electrical induction and lighting effect. For Aerial Installation, Dry Core Technology (All Dielectric Self Supporting) Fiber Type Cable Size G652 A ~ D G653 A & B G654 A ~ C G655 A ~ E 6 - 36 24 - 72 60 – 96 6 6 6 8 Loose Tube Number 4 6 12 12 Max.Tube OD (mm) Fiber Number per Lose Tube 2.2 2.5 3.5 3.5 Max.Cable outer Diameter (mm) 13.6 14.5 17.5 19.5 4 ~ 264 Cores Loose Tube Number Fiber Count Standard 4 - 16 ITU-T G Series IEC 60793/IEC 60794 IEC 60304 IEC 60587 Telecordia GR-20 1 2 3 4 5 6 4 4 Filler Filler Filler Filler Filler 6 6 Filler Filler Filler Filler Filler 12 4 4 Filler Filler 4 Filler 12 6 Filler Filler 6 Filler Filler 16 4 4 Filler 4 4 Filler 18 6 6 Filler Filler 6 Filler 24 6 6 Filler 6 6 Filler 24 12 Filler Filler 12 Filler Filler 36 6 6 6 6 6 6 36 12 12 Filler Filler 12 Filler 48 12 12 Filler 12 12 Filler 60 12 12 12 12 12 Filler 72 12 12 12 12 12 12 Loose Tube Number Fiber Count 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 1. 2. 3. 4. 5. HDPE Anti Tracking sheath Water Blocking Tape Peripheral strength member (Aramid Yarn) Filler Rod Non Metalic Central Strength Member (GRP + PE coated) 6. Ripcord 7. Water Blocking Yarn 8. Single mode color code optical fiber 9. Gel filed PBTP color coded tube Number of Fiber Property 1 - 16 18 - 36 48 60 - 72 Tensile Strength > 12.000 > 12.000 > 12.000 > 12.000 Crush Resistance ≥2 ≥2 ≥2 ≥2 ± 172 ± 235 ± 240 ± 292 Max. Weight Unit 84-96 > 12.000 N ≥2 KN/100mm ± 298 Kg/km Min. Bending mm Proof Test > 0.5 % Filler 4 4 Filler Additional Loss < 0.1 dB Filler Filler 6 Filler Radius 30 mm Filler 6 6 Filler Number of Turn 100 - Filler 12 Filler Filler Property Value Unit Proof Test > 0.5 % Additional Loss < 0.1 dB Radius 30 mm Number of Turn 100 - OPTICAL FIBER CABLE FOR AERIAL INSTALLATION TYPICAL SPECIFICATION This is optical fiber cable intregated with a messenger wire for aerial installation. This cable is loose tube core. If armouring is necessary to prevent damage by rodents, insects, and shot guns, a peripheral high strength yarn can applied. Non Metallic Central Strength Member Optical Fiber Central Strength Member Jacket Filler Rod Loose Tube Aramid Yarn for Binder Fiber Type Water Blocking Tape Aluminium Tape Messenger Wire Aramid Yarn for Ripcord Cable Size Standard G652 A ~ D G653 A & B G654 A ~ C G655 A ~ E 4 ~ 264 Cores ITU-T G Series IEC 60793/IEC 60794 IEC 60304 STEL K-017-2008 ver. 2.0 Outer Sheath 2 3 4 5 6 7 8 9 10 1. 2. 3. 4. 5. 6. HDPE sheath Steel wire messenger Laminated Aluminum Polyethylene type Water Blocking Tape Peripheral strength member (Aramid Yarn). Non Metalic Central Strength Member (GRP + PE coated) 7. Ripcord 8. Filler Rod 9. Single mode color code optical fiber 10. Gel filed PBTP color coded tube 4 - 16 6 - 36 24 - 72 60 – 96 6 6 6 8 Loose Tubes Number 4 6 12 12 Max.Tube OD (mm) Fiber Number per Loose Tube 2.2 2.5 3.5 3.5 Max. Cable Outer Diameter (mm) 13.5 17.5 17.5 17.5 Loose Tube Number Fiber Count 1 2 3 4 5 6 4 4 Filler Filler Filler Filler Filler 6 6 Filler Filler Filler Filler Filler 8 4 Filler Filler 4 Filler Filler 12 4 4 Filler Filler 4 Filler 12 6 Filler Filler 6 Filler Filler 16 4 4 Filler 4 4 Filler 18 6 6 Filler Filler 6 Filler 24 6 6 Filler 6 6 Filler 24 12 Filler Filler 12 Filler Filler 36 6 6 6 6 6 6 36 12 12 Filler Filler 12 Filler 48 12 12 Filler 12 12 Filler 60 12 12 12 12 12 Filler 72 12 12 12 12 12 12 Loose Tube Number Fiber Count 1 Number of Fiber Item 1 2 3 4 60 12 12 Filler Filler 12 5 12 6 12 7 Filler 8 72 12 12 12 Filler 12 12 12 Filler 84 12 12 12 12 12 12 12 Filler 96 12 12 12 12 12 12 12 12 Mechanical Characteristic Number of Fiber Property 1 - 16 18 - 36 48 60 - 72 Tensile Strength > 2700 > 2700 > 2700 > 2700 Crush Resistance ≥2 ≥2 ≥2 ≥2 Max. Weight ± 228 ± 228 ± 228 ± 228 Min. Bending 225 270 300 300 Characteristic Value Unit 84-96 > 2700 N ≥2 KN/100mm ± 228 Kg/Km 300 mm Unit Proof Test 1 % Additional Loss < 0.1 dB Radius 30 mm Number of Turn 100 - OPTICAL FIBER FOR DIRECT BURIED INSTALLATION This is optical fiber cable a corrugated steel tape or steel wire armoring for protection. They are used as direct buried, anti ballistic, anti rodent, anti termite cables whenever mechanical strength is required. This cable is loose tube core. For Direct Buried Installation TYPICAL SPECIFICATION Fiber Type G652 A ~ D G653 A & B G654 A ~ C G655 A ~ E Cable Size 4 ~ 264 Cores Standard ITU-T G Series IEC 60793/IEC 60794 IEC 60304 STEL K-016-2008 ver. 2.0 5 6 7 8 9 10 11 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. HDPE sheath Corrugated Steel Tape Armor MDPE inner sheath Laminated Aluminum Polyethylene type Non metalic central strength member (GRP+PE coated) Water Blocking Tape Ripcord Peripheral strength member (Aramid Yarn). Filler Rod Gel filed PBTP color coded tube Single mode color code optical fiber 4 - 16 6 - 36 24 - 72 60 – 96 6 6 6 8 Loose Tubes Number 4 6 12 12 Max.Tube OD (mm) Fiber Number per Loose Tube 2.2 2.5 3.5 3.5 Max. Cable Outer Diameter (mm) 18.2 22.2 22.2 22.2 Loose Tube Number Fiber Count 1 2 3 4 5 6 4 4 Filler Filler Filler Filler Filler 6 6 Filler Filler Filler Filler Filler 12 4 4 Filler Filler 4 Filler 12 6 Filler Filler 6 Filler Filler 16 4 4 Filler 4 4 Filler 18 6 6 Filler Filler 6 Filler 24 6 6 Filler 6 6 Filler 24 12 Filler Filler 12 Filler Filler 36 6 6 6 6 6 6 36 12 12 Filler Filler 12 Filler 48 12 12 Filler 12 12 Filler 60 12 12 12 12 12 Filler 72 12 12 12 12 12 12 72 12 12 12 12 12 12 Loose Tube Number Fiber Count 1 2 3 4 Number of Fiber Item 1 2 3 4 5 6 7 8 60 12 12 Filler Filler 12 12 12 Filler 72 12 12 12 Filler 12 12 12 Filler 84 12 12 12 12 12 12 12 Filler 96 12 12 12 12 12 12 12 12 Mechanical Characteristic Number of Fiber Property Unit 1 - 16 18 - 36 48 60 - 72 Tensile Strength > 2700 > 2700 > 2700 > 2700 > 2700 N Crush Resistance ≥ 4.5 ≥ 4.5 ≥ 4.5 ≥ 4.5 ≥ 4.5 KN/100mm Max. Weight ± 326 ± 446 ± 467 ± 471 ± 473 Kg/Km Min. Bending ≤ 250 ≤ 270 ≤ 300 ≤ 300 ≤ 300 mm Characteristic Value 84-96 Unit Proof Test 0.5 % Additional Loss < 0.1 dB Radius 30 mm Number of Turn 100 - OPTICAL FIBER CABLE FOR DROP WIRE INSTALLATION TYPICAL SPECIFICATION Type Specification Drop Aerial Cable Number of Fiber Item Drop cable being made to accommodate FTTH system telecommunication industry as for wiring from terrestrial to Ethernet system. Designed to short distance span with easy connection from end – user to nearby fiber access terminal. This cable consist of 1 up to 4 fiber core with to FRP in both inside to avoid shrieked in its cable jacketing. There are two kinds cable (Aerial and Burial) 1 2 4 Max. Cable Height (mm) 5 – 5.5 5 – 5.5 1.2 Max. Cable Width (mm) 2 - 2.5 2 - 2.5 12.5 Type Specification Single Drop Burial Cable Number of Fiber Item Construction DROP Aerial Cable 1 2 3 1 2 4 Max. Cable Height (mm) 3 - 3.5 3 - 3.5 3 - 3.5 Max. Cable Width (mm) 2 - 2.5 2 - 2.5 12.5 Mechanical Characteristic Number of Fiber 2012 VOKSEL KABEL OPTIK/G657A /DW 2F Fiber Count 4 5 1. 2. 3. 4. 5. Steel Wire Messenger PBT Loose Tube Optical Fiber PE Sheath GRP Strength Member Construction DROP burial Cable 2012 VOKSEL KABEL OPTIK/G657A /DW 2F 3 4 1 2 1. 2. 3. 4. PE Sheath GRP Strength Member PBT Loose Tube Optical Fiber 1 2 4 Unit Tensile Strength > 130 > 130 > 130 N Crush Resistance ≥ 0.3 ≥ 0.3 ≥ 0.3 kg Max. Weight ± 10 ± 10 ± 38 Kg/Km Min. Bending 20 X OD 20 X OD 20 X OD Characteristic Value mm Unit Proof Test 1 % Additional Loss < 0.1 dB Radius 15 mm OPTICAL FIBER FOR DUCT INSTALLATION TYPICAL SPECIFICATION Number of Fiber Item This is optical fiber cable is with loose tube core. It is quite suitable to the system requiring more optical fibers. The fibers are accommodated in jelly filled tubes with an excess length. If a flame retardant characteristic is required, a special material can be applied as the outer sheath. For Duct Installation Fiber Type Cable Size Standard G652 A ~ D G653 A & B G654 A ~ C G655 A ~ E ITU-T G Series IEC 60793/IEC 60794 IEC 60304 STEL K-016-2008 ver. 2.0 5 6 7 8 9 10 HDPE sheath Laminated Aluminum Polyethylene type Water Blocking Tape Metalic/non metalic central strength member Peripheral strength member (Aramid Yarn). Ripcord Filler Rod Flooding compound (Jelly) / non Jelly (dry cable type). Gel filed PBTP color coded tube Single mode color code optical fiber 24 - 72 60 – 96 Loose Tubes Number 6 6 6 8 4 6 12 12 Max.Tube OD (mm) 2.2 2.5 3.5 3.5 Max. Cable Outer Diameter (mm) 13.5 17.5 17.5 17.5 4 ~ 264 Cores 1 2 3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 6 - 36 Fiber Number per Loose Tube Loose Tube Number Fiber Count 1 2 3 4 5 6 4 4 Filler Filler Filler Filler Filler 6 6 Filler Filler Filler Filler Filler 12 4 4 Filler Filler 4 Filler 12 6 Filler Filler 6 Filler Filler 16 4 4 Filler 4 4 Filler 18 6 6 Filler Filler 6 Filler 24 6 6 Filler 6 6 Filler 24 12 Filler Filler 12 Filler Filler 36 6 6 6 6 6 6 36 12 12 Filler Filler 12 Filler 48 12 12 Filler 12 12 Filler 60 12 12 12 12 12 Filler 72 12 12 12 12 12 12 72 12 12 12 12 12 12 Loose Tube Number Fiber Count 4 4 - 16 1 2 3 4 5 6 7 8 60 12 12 Filler Filler 12 12 12 Filler 72 12 12 12 Filler 12 12 12 Filler 84 12 12 12 12 12 12 12 Filler 96 12 12 12 12 12 12 12 12 Mechanical Characteristic Number of Fiber Property 1 - 16 18 - 36 48 60 - 72 Tensile strength > 2700 > 2700 > 2700 > 2700 Crush Resistance ≥2 ≥2 ≥2 ≥2 Unit 84-96 > 2700 N ≥2 KN/100mm Max.Weight ± 172 ± 273 ± 275 ± 278 ± 281 Kg/Km Min.Bending (No Load) ≤ 250 ≤ 270 ≤ 300 ≤ 300 ≤ 300 mm Min.Bending (Under Load) ≤ 250 ≤ 270 ≤ 300 ≤ 300 ≤ 300 mm Characteristic Value Unit Proof Test > 0.5 % Additional Loss < 0.1 dB Radius 30 mm Number of Turn 100 - OPTICAL FIBER CABLE FOR AERIAL INSTALLATION TYPICAL SPECIFICATION Type Specification Single Core Per Tube Aerial Number of Fiber Item In fiber optic, Single Core Per Tube is one type of cable used to capture one or more optical fiber for the FTTH (Fiber to The Home) Distribution cable. With design easier to split the fiber core and connecting to termination box as well as the loose tube type is compatible in humidly temperature capacity 8 – 24 Core. There are two kind type cable FTTH (Aerial Application Cable and Duct Application Cable) Standard STEL QA – K – 036 –2012 Specification (AERIAL) STEL QA – K – 037 – 2012 (DUCT) 8 10 12 18 24 Loose Tubes Number 8 10 12 18 8 Fiber Number per Loose Tube 1 1 1 1 1 Max.Tube OD (mm) 1.2 1.2 1.2 1.2 1.2 Max. Cable Outer Diameter (mm) 10.6 11.6 12.5 13.5 15 Type Specification Single Core Per Tube Duct Construction Single Core Per Tube Aerial Cable Non Metallic Central Strength Member Optical Fiber Aramid Yarn for Binder Loose Tube Messenger Wire 8 10 12 18 24 Loose Tubes Number 8 10 12 18 8 Fiber Number per Loose Tube 1 1 1 1 1 Max.Tube OD (mm) 1.2 1.2 1.2 1.2 1.2 Max. Cable Outer Diameter (mm) 10.6 11.6 12.5 13.5 15 Central Strength Member Jacket Water Blocking Tape Jumlah Serat Optik 18 Lapis 1 1 1 1 1 1 1 - Black HDPE Sheath Filler Rod Aluminium Tape VOKSEL 2013 FIBER OPTIC / SM.D / A 24 / 24 T Messenger Wire Outer Sheath Number of Fiber Item Aramid Yarn for Ripcord Moisture Barrier Non Laminated Water Blocking Yarn High Tensile Aramid Yarn Ripcord Aramid Yarn High Tensile Aramid Yarn Loose Tube Nomor urut serat/ Tube 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Optical Fiber FRP with PE Coated Construction Single Core Per Tube DUCT Cable Black HDPE Sheath Moisture Barrier Non Laminated Water Blocking Yarn High Tensile Aramid Yarn Ripcord Aramid Yarn High Tensile Aramid Yarn Loose Tube VOKSEL 2013 / FIBER OPTIC / SM.D / D 24 / 24 T Optical Fiber FRP with PE Coated 8 Lapis 1 1 1 1 1 1 1 1 1 - 10 Lapis 1 1 1 1 1 1 1 1 1 1 - 12 Lapis 1 1 1 1 1 1 1 1 1 1 1 1 1 - 24 Lapis 2 1 1 1 1 1 1 1 1 1 1 1 1 - Lapis 1 1 1 1 1 1 1 1 1 1 - Lapis 2 1 1 1 1 1 1 1 Filler 1 1 1 1 1 1 1 Filler Mechanical Characteristic Number of Fiber Fiber Count 8 10 12 18 Unit 24 Tensile strength > 2850 > 2850 > 2850 > 2850 > 2850 N Crush Resistant ≥ 2,2 ≥ 2,2 ≥ 2,2 ≥ 2,2 ≥ 2,2 KN/100mm Max. Weight ± 185 ± 200 ± 210 ± 215 ± 240 Kg/Km Min. Bending 20 X OD 20 X OD 20 X OD 20 X OD 20 X OD mm Characteristic Value Unit Proof Test 1 % Additional Loss < 0.1 dB Radius 30 mm Number of Turn 100 - JUMPER WIRE DROP WIRE Poly Vinyl Chloride insulated Jumper Wires are designed for cross connecting of jumping usage, on MDF,IDF, and other connecting circuit in cable house. Conductor Diameter mm 0.6 Cable Size Pair 1 PVC Insulations Thickness mm 0.3 mm 2.4 2 x 1 x 0.5 External Diameter STEEL K-006 Cable Weight SII 0616-82 m 500 SNI 04-2068-1990 Standard Packing Length R-V Drum Volume m3 - Type of Product Jumper Wire Cable Size Ref. Standard Cable Designation DESCRIPTION 2 x 1 x 0.6 Aerial Drop wires are designed for installations, from distribution cables to subcribers or for installations on external wall of buildings or houses Jumper Wire Dimensions kg/km mm 0.6 0.8 Cable Size Pair 1 1 mm 1.0 1.0 2 x 1 x 0.6 PE Insulation Thickness 2 x 1 x 0.8 Cable Width mm 5.9 5.9 Ref. Standard 8 Suspension Strand mm 1/1.2 1/1.2 kg/km 31 36 Standard Packing Length m 500 500 Drum Volume m3 - - Coil Coil STEEL K-004 SII 064-82 SNI 04-2066-1990 Drum Type UNIT Conductor Diameter Type of Product Drop Wire Cable Size Cable Designation Coil Drop Wire Dimensions U - ES Cable Weight Drum Type SPECIFICATION ELECTRICAL AND MECHANICAL DATA : Conductor resistance at 20 ± 1ºC Maximum Individual Min. Insulation resistance at 5000 V DC DESCRIPTION Ohm/km M Ohm.km/minute 65.00 100 MECHANICAL CHARACTERISTICS : Min. Elongation of copper conductor Min. Tensile Strength of PVC insulation Min.Elongation of PVC insulation % N/mm² % 18 12.5 12.5 UNIT ELECTRICAL AND MECHANICAL DATA : Conductor resistance at 20 ± 1ºC Maximum Individual Min. Insulation resistance at 5000 V DC Ohm/km M Ohm.km/minute 65.00 10,000 MECHANICAL CHARACTERISTICS : % N/mm² % Min. Elongation of copper conductor Min. Tensile Strength of PVC insulation Min.Elongation of PVC insulation Cable Construction SPECIFICATION 18 1255 300 PVC Insulation Galvanised Steel Wire (GSW) Copper Conductor PVC Insulation Installation Colour Pair Number Steel Wire (1 x 1.2 mm) Single Core (Copper) PE Sheath (Black) Colour of Insulation “A” Wire “B” Wire 1 White Blue 2 White Red 3 White Black 4 Blue Red Black PE Sheath Single Core (Copper) Cable Marking Copper Conductor (2 x 0.6 mm) PT. VOKSEL ELECTRIC Tbk. EXECUTIVE OFFICE Menara Karya 3rd Fl. Suite D Jl. HR. Rasuna Said Block X-5 Kav 1-2 Jakarta 12950 Indonesia Ph. +62 21 5794 4622 Fx. +62 21 5794 4649 FACTORY & OPERATIONAL OFFICE Jl. Raya Narogong Km 16 Cileungsi Bogor 16820 Indonesia Ph. +62 21 823 0525 +62 21 8249 1720 +62 21 8249 1712 Fx. +62 21 823 0526 +62 21 8249 1701 Hotline: + 62 21 8249 3329 E-mail: [email protected] [email protected]