Programmable Thermostats Programmable Thermostats
Transcription
Programmable Thermostats Programmable Thermostats
Programmable Thermostats Type 510, 511, 512 for HRF Heating Systems with Cooling and Slab Temperature Limits Actual Size The 510 / 511 can be used in place of any single Adding a floor sensor to the 510 / 511 allows stage programmable thermostat. for floor warming or slab temperature limiting. Schedules allow for alternate periods of floor warming and / or space heating. Adding a floor sensor to the 512 allows for two The 512 can be used in place of any two stage stage heating with floor temperature limiting to programmable thermostat. The second stage only operates when the first stage cannot main- help protect surface coverings. tain the space temperature. The 512 can be used in place of any heating and cooling programmable thermostat. © 2002 P 185 - 01/02 The 512 can maintain a warm floor while cooling for comfort. 2 of 4 Add an outdoor sensor to either the 510 / 511 or 512 to display the outdoor temperature. Add two slab sensors to either the 510 / 511 or 512 to read an average slab temperature for large areas. Add a remote sensor to either the 510 / 511 or 512. This allows the user to either: - view a temperature at a remote location - control the temperature at a remote location or - read an average temperature between the thermostat and the remote location. Mount several thermostats in a central location and use remote sensors to control remote zones. 3 of 4 © 2002 P 185 - 01/02 510 511 + Features: 1 Stage Heat 2 Stage Heat, 1 Stage Heat / 1 Stage Cool Air and / or Slab Temperature Control Slab Minimum for Floor Warming Slab Maximum to Help Protect Surface Coverings Heat, Cool, Auto Change Over 2 Remote Sensor Inputs for Indoor, Outdoor and / or Slab Temperature 7 Day or 24 Hour Schedules 2 or 4 Temperatures per Day Permanent or Temporary Overrides 3 Hour Hold Feature Away Override for Periods of Extended Absence Programs Do Not Need to be Reset After Power Outages 4 Hour Clock Back-up (No Battery Required) Early Start Feature for Recovery From Setback Backlighting of the Display User and Installer Access Levels 24 V (ac) Power Supply 24 V (ac) 2 Amp Relays Adjustable Heating Cycles per Hour Adjustable Cooling Cycles per Hour Adjustable Heating / Cooling Interlock Time for Auto Change Over Adjustable Minimum On Times for Cooling Adjustable Minimum Off Times for Cooling • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 512 • • • • • • • • • • • • • • • • • • • • • • • Reference Material — E 006 Control of Radiant Floor Heating Zones Programmable Thermostat - 510, 511, 512 Literature Control Dimensions Approvals Ambient conditions Power supply Relays Sensors Included Optional Control Systems — — — — — — — — — — D 510, U 510, D 079 (511 Only) Microprocessor PI control; This is not a safety (limit) control 2-7/8” H x 2-7/8” W x 13/16” D (73 x 73 x 21 mm) CSA C US, meets ICES & FCC regulations for EMI/RFI Indoor use only, 32 to 122°F (0 to 50°C), < 90% RH non-condensing 24 V ±10% 60 Hz 3 VA 24 V (ac) 2 A, Latching NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892 Slab Sensor 079 (511 Only) tekmar type #: 070, 071, 072, 073, 076, 077, 078, 079 tekmar Control Systems Ltd., Canada tekmar Control Systems, Inc., U.S.A. Head Office: 4611 - 23rd Street Vernon, B.C. Canada V1T 4K7 (250) 545-7749 Fax. (250) 545-0650 Web Site: www.tekmarcontrols.com Product design, software and literature are Copyright © 2002 by: tekmar Control Systems Ltd. and tekmar Control Systems, Inc. 4 of 4 All specifications are subject to change without notice. Printed in Canada. P 185 - 01/02.