Programmable Thermostats Programmable Thermostats

Transcription

Programmable Thermostats Programmable Thermostats
Programmable Thermostats
Type 510, 511, 512
for HRF Heating Systems with
Cooling and Slab Temperature Limits
Actual Size
The 510 / 511 can be used in place of any single Adding a floor sensor to the 510 / 511 allows
stage programmable thermostat.
for floor warming or slab temperature limiting.
Schedules allow for alternate periods of floor
warming and / or space heating.
Adding a floor sensor to the 512 allows for two
The 512 can be used in place of any two stage
stage heating with floor temperature limiting to
programmable thermostat. The second stage
only operates when the first stage cannot main- help protect surface coverings.
tain the space temperature.
The 512 can be used in place of any heating
and cooling programmable thermostat.
© 2002
P 185 - 01/02
The 512 can maintain a warm floor while cooling for comfort.
2 of 4
Add an outdoor sensor to either the 510 / 511
or 512 to display the outdoor temperature.
Add two slab sensors to either the 510 / 511 or 512
to read an average slab temperature for large areas.
Add a remote sensor to either the 510 / 511 or
512. This allows the user to either:
- view a temperature at a remote location
- control the temperature at a remote location
or
- read an average temperature between the
thermostat and the remote location.
Mount several thermostats in a central location and use remote sensors to control remote
zones.
3 of 4
© 2002
P 185 - 01/02
510
511
+
Features:
1 Stage Heat
2 Stage Heat, 1 Stage Heat / 1 Stage Cool
Air and / or Slab Temperature Control
Slab Minimum for Floor Warming
Slab Maximum to Help Protect Surface Coverings
Heat, Cool, Auto Change Over
2 Remote Sensor Inputs for Indoor, Outdoor and / or Slab Temperature
7 Day or 24 Hour Schedules
2 or 4 Temperatures per Day
Permanent or Temporary Overrides
3 Hour Hold Feature
Away Override for Periods of Extended Absence
Programs Do Not Need to be Reset After Power Outages
4 Hour Clock Back-up (No Battery Required)
Early Start Feature for Recovery From Setback
Backlighting of the Display
User and Installer Access Levels
24 V (ac) Power Supply
24 V (ac) 2 Amp Relays
Adjustable Heating Cycles per Hour
Adjustable Cooling Cycles per Hour
Adjustable Heating / Cooling Interlock Time for Auto Change Over
Adjustable Minimum On Times for Cooling
Adjustable Minimum Off Times for Cooling
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
512
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Reference Material
— E 006 Control of Radiant Floor Heating Zones
Programmable Thermostat - 510, 511, 512
Literature
Control
Dimensions
Approvals
Ambient conditions
Power supply
Relays
Sensors
Included
Optional
Control Systems
—
—
—
—
—
—
—
—
—
—
D 510, U 510, D 079 (511 Only)
Microprocessor PI control; This is not a safety (limit) control
2-7/8” H x 2-7/8” W x 13/16” D (73 x 73 x 21 mm)
CSA C US, meets ICES & FCC regulations for EMI/RFI
Indoor use only, 32 to 122°F (0 to 50°C), < 90% RH non-condensing
24 V ±10% 60 Hz 3 VA
24 V (ac) 2 A, Latching
NTC thermistor, 10 kΩ @ 77°F (25°C ±0.2°C) ß=3892
Slab Sensor 079 (511 Only)
tekmar type #: 070, 071, 072, 073, 076, 077, 078, 079
tekmar Control Systems Ltd., Canada
tekmar Control Systems, Inc., U.S.A.
Head Office: 4611 - 23rd Street
Vernon, B.C. Canada V1T 4K7
(250) 545-7749 Fax. (250) 545-0650
Web Site: www.tekmarcontrols.com
Product design, software and literature are Copyright © 2002 by:
tekmar Control Systems Ltd. and tekmar Control Systems, Inc.
4 of 4
All specifications are subject to change without notice.
Printed in Canada. P 185 - 01/02.