7. GREENCRAFT BUILDERS COLLEYVILLE HOUSE
Transcription
7. GREENCRAFT BUILDERS COLLEYVILLE HOUSE
BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7. GREENCRAFT BUILDERS COLLEYVILLE HOUSE, COLLEYVILLE, TX 7.1 Executive Summary Gate 2 - Prototype: Colleyville House, Greencraft Builders, Dallas, TX Overview !" " !"!! !"!" !!% !% '! ##!!!" (!)&!!!( ! )" !'%#" $ !"!!! ! ! %& "!% " !!%'! "!% !!!!% !"!!! " !!% "#!' Key Results %#" $ !"!!" ! %! " '!$ # !!" " ! !!"!!$ "%%' " ! %#! #!% ""!' Gate Status Table 7.1-1: Stage Gate Status Summary “Must Meet” Gate Criteria Status Summary Source Energy Savings Pass The Colleyville house meets the 50% minimum source energy savings threshold as defined by the 2009 Building America Benchmark. Prescriptive-Based Code Approval Pass The Colleyville House meets the local building code – 2003 IBC. Quality Control Requirements Pass Greencraft maintains quality control through constant communication and onsite reviews by the builder and the architect. Detailed drawing sets from the architect and documented specifications from BSC augments the quality service that Greencraft provides. “Should Meet” Gate Criteria Status Summary Neutral Cost Target Pass This home exceeds the neutral cost target when the cost of improvements is financed as part of a 30 year mortgage. This annual amortized cost is less than the energy savings of the homes compared to the BA Benchmark. Quality Control Integration Pass Quality control is specified by documents between Greencraft and Building Science Corporation. Gaps Analysis Pass BSC and Greencraft attempted to integrate XPS insulation on the slab edge but were unable to. Greencraft will try to include this and other characteristics in future homes. Conclusions %#" " ! ! !"!%!" & "! &' " !"!%+**, D-466 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House )'',%"$ "#$% #+'-$! $ %$! *'"*%'! *," "% #!&*(+) $ ! %" " "$" % D-467 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.2 Introduction 7.2.1. Project Overview "! !$!!" .,,0 #"$! )! " "& !"!&! & )&#$$! !!( ! ($ ' &! !"!) ! "!! !! ' !! " !" ) &#" !$.,,3!!& ) ! ! ! % #!!! !"! !!" )! !$* !& ! $!!!/221 ) !"! &.,,2$ .,,3) !!%! ! )$ !! ) Figure 7.2-1: Colleyville House – 2009 Greencraft Prototype House " " "! !! "!"!% # !)$ .%1#$!$ !& & !#!&$!-+ "! !) "#!!' !!$!*.,$ !& &!!#! )" "! "# !!!$!!)"! "! !!#"! !! !!"!!&")#!!# "! !! !&&) D-468 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.2.2. Project Information Summary Sheet PROJECT SUMMARY Company GreenCraft Builders L.L.C. Company Profile GreenCraft Builders L.L.C. is the culmination of more than 30 years of experience building and remodeling homes in the Dallas/Fort Worth metroplex. Since 2004, Chris Miles, principal of GreenCraft, has been recognized as a leader in the North Texas green building industry, first as a producer and project manager, and now as a builder with his company, GreenCraft Builders L.L.C. Contact Information Chris Miles GreenCraft Builders L.L.C. 105 West Main Street Lewisville, TX 75057 (214) 718-8424 http://www.greencraftbuilders.com/ Company Type Custom Home Builder Address 1708 Oak Knoll Drive City, State Colleyville, TX 76034 Climate Region Mixed-Humid, IECC Zone 3A SPECIFICATIONS Number of Houses 1 Municipal Address 1708 Oak Knoll Drive, Colleyville, TX 76034 House Style Single Family Detached with attached garage Number of Stories 2 Number of Bedrooms 4 Plan Number(s) Arnett House Floor Area 4886 ft Estimated Energy Reduction 70.5% over BA Benchmark Estimated Energy Savings $3459 annual savings Estimated Cost $960,000 or $196/ft Construction Start May 2008 Construction Finish March 2009 2 2 7.2.3. Targets and Goals !! &%' ! " ! !# $$ !!" D-469 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House !"") #$ "$!" $)""$'#$ #$"%$!" $ $)! %#$$ #$"$#)"))+%"$)+#%#$$)$%"#-& "$$ #%, • %"%"#" " • 2. • "%$3 "$(# • $ "%" "3. • ")$"2 " # ! # $5448 )& %#", • !" $#!") %&$" ##$&')$ $$ #)#$'$$% #%"+$ "%%$"$ - • %$*%!$%%"01&"$ #%" #$"%$ -# ##$# 5(7#$%#$56/ --'$$' #$%") ""#+#$ !!$"%$ ' '"-# %# #$"'$ $$ " #$#" $"%####!$56/ -- • %"#%!!$%$ $ !" &% "$ $" #!"$" $#)#$- D-470 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.3 Whole-House Performance and Systems Engineering 7.3.1. Energy Analysis Summary Table 7.3-1: Estimated Whole House Energy Use for the Colleyville House (# % (# &'!%) #! $" Table 7.3-2: Estimated House Energy Net Generation for the Colleyville House D-471 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.3.1.1. Parametric Energy Simulations Figure 7.3-1: Parametric energy simulations for the Colleyville House $! # $$/*1 " ' "!$ $!'(% ")& +' ,' +1" -' *'0,+**, .' $ """-$! D-472 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.3.1.2. End-Use Site and Source Energy Summaries Table 7.3-3: Summary of End-Use Site-Energy Table 7.3-4: Summary of End-Use Source-Energy and Savings D-473 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.3.2. Discussion 7.3.2.1. Enclosure Design Table 7.3-5: Enclosure Specifications ENCLOSURE SPECIFICATIONS Ceiling Description - Standing Seam metal roof - Unvented Cathedralized Attic Insulation - 8.6” R-30 low density open cell spray foam in roof rafter cavity Walls Advance Framed with ”OSB at the corners for structural Description - 2x6 wood studs 24” o.c., two stud corners single top plate Stacked framing with floor joists and roof trusses at 24”o.c. Insulation - R-20 low density open cell spray foam +1” R-5 XPS insulating sheathing Description - Slab on grade – Post Tensioned with Termimesh barrier system Foundation ® Slab is 51% fly ash Insulation - Non insulated Description - Double Pane Fiberglass Framed Windows ® Manufacturer - Pella Impervia ® 2 U-value - U = 0.28 Btu/hr-ft °F SHGC - SHGC = 0.24 Specification - 2.5 in leakage area per 100 ft enclosure, 3149 CFM 50, 2.5 ACH 50 Performance test - 0.9 in leakage area per 100 ft enclosure, 1097 CFM 50, 0.9 ACH 50 Infiltration 2 2 2 2 D-474 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Figure 7.3-2: Enclosure Building Section D-475 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House $# & $! # !#%& !#&! $! ($ )& Figure 7.3-3: Unvented cathedralized attic with foam installed Figure 7.3-4: Open cell low density spray foam in walls and unvented cathedralized attic # & Figure 7.3-5: Fully adhered roofing membrane installed before standing seam roof Figure 7.3-6: Standing seam metal roof &*,' &!*"-*,'! &! !!&* +,"$ #&! *,'&!!! D-476 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House !"#" "!" #"# *!%! !#""" !*# !#"("%%!) !#" "!"#'#"* Figure 7.3-7: Advanced framed walls – 2x6 studs at 24” o.c. Figure 7.3-8: Stacked framing with a 2x6 splice joining two single top plates " "$ !"!! !"#!"" %%!"#!*! "!! ' !" #"# !"$* " !!" !##!!"" "!# #"!!"# !"* Figure 7.3-9: No cripples installed next to the jack studs Figure 7.3-10: Two windows with no adjacent to jack studs %%! # !! %"!""" "/"" $"!" %%!" !"!" #"#!" '* !! ! #!" !'!""$'*! !#"! #"' "# $# "'* &" %!$3,!#"!"*! #!" '!!! " " #"&" !"#!*"" !2,!!" !" #"# !# "*!!"0+ " ""% !#!" 3, "*1, !!"$ ""!#"" $ !"!# "#"!" #""&" %*# ".'$- D-477 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House (!% ! !!#% "!%!! ## # !#%!# !!% 3 Figure 7.3-11: Fiberglass LoE windows Figure 7.3-12: Window with cladding installed $!#% +*-#%!$ ! #% # % Figure 7.3-13: Slab reinforcement before casting Figure 7.3-14: 51% Fly Ash post tensioned slab on grade ##!$% !! % #&)%, *%+ ' D-478 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Figure 7.3-15: Low density open cell spray foam in unvented cathedralized attic (R-30) and walls (R-20) Figure 7.3-16: Low density open cell spray foam in attic knee walls 7.3.2.2. Mechanical System Design Table 7.3-6: Mechanical system specifications MECHANICAL SYSTEMS SPECIFICATIONS Heating (outdoor unit) Description - 4.1 COP Ground Source Heat Pump Manufacturer & Model - WaterFurnace® Envision™ Series Cooling (outdoor unit) Description - 18.8 EER Ground Source Heat Pump Manufacturer & Model - WaterFurnace® Envision™ Series Air Handler (indoor unit) Description - Variable Speed Air Handler + High Efficiency Air Filter Manufacturer & Model - WaterFurnace® Envision™ Series + GeneralAire® AC22 filter Domestic Hot Water Description - Instantaneous Tankless Hot Water + Separate tank for GSHP DHW Manufacturer & Model - Rinnai® R94LSi (0.82 EF) + 30 Gal. A.O. Smith ® ProMax® tank Distribution Description - Duct board and R-6 flex duct run outs in conditioned attic Leakage - 430 CFM 25 (18%) total, 30 CFM 25 (1.0%) to outside Ventilation Description - Central Fan Integrated Supply (CFIS) ventilation system 50 CFM 33% Duty Cycle: 10 minutes on; 20 minutes off Energy Recovery Ventilator Inline exhaust fan for all bathrooms D-479 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House MECHANICAL SYSTEMS SPECIFICATIONS Manufacturer & Model - Aprilaire® Model 8126 Ventilation Control System (VCS) Fantech FR 150 inline exhaust fan for all bathrooms Dehumidification Description - Supplemental dehumidification system Manufacturer & Model - GeneralAire® Model 1300 Whole House Dehumidifier Return Pathways Description - R-6 flex ducts to bedrooms and laundry room Description - 3 kW array Manufacturer & Model - Supplier: Meridian Solar | Manufacturer: Sharp® Corporation PV System % $!# '*%## &$ &#%!&!-% % $)($(##633%!58%!#%# %#- '# $*$%$#%%7-4%4;-; - Figure 7.3-17: Well drilling Figure 7.3-18: HVAC system located in the conditioned unvented cathedralized attic '#$*$% $%($# &25:,333% %- ###$ '#$!&%# %#-&%( #$ %$ % $!%&'%%#+%%- %&%($&!# ''#$&$ %533;##%$%# &$/4;<'$-6;<0-&%% &%$($( ( %8<#"&#%/4<0- &%$#'%% $$%# %#%&!!*/ 0'%% %% $ %# *%!##1 ;459*#%%$$%%%$&!!* !&-9.$&%)&%#($ &%$## )%# #( % &!$%% %-#$!# %$&%%%$ %# *% *#% !#'% '#'%% &#!# $ !#% -*#$ %&#$ %## &#!# $ ( !#% % # &%$# )%%# ##-$$&#$!# !#'%% %$ &$ # '# %-%# )&$%$# %!#% $)&$%&% %%$! (#'%%483- D-480 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House !# Figure 7.3-19: Central Fan Integrated Supply Ventilation Schematic with Supplemental Dehumidification ! !!# Figure 7.3-20: (L-R) GeneralAire® AC22 Filter and Aprilaire® 8126 VCS control panel on supply plenum Figure 7.3-21: (L-R) GeneralAire® AC22 Filter, WaterFurnace® Air Handler and GeneralAire® Model 1300 whole house dehumidifier on top of air handler ! $" !# !!" !!# !# ! !!# !!!# !%'(&& D-481 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House "& " ! $ &" & 7.3.2.3. Lighting and Miscellaneous Electrical Loads $! )((. %" )(. -(. !$"& $&%" "$ & 7.3.2.4. Site-generated Renewable Energy *&($ '&# +(-( $%"!+, $ & Figure 7.3-22: 3.0 kW Photovoltaic System D-482 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.4 Construction Support 7.4.1. Construction Overview ! $%#&%! *3118 $ #3119-# #% !%! #!$$ *!# !$&#!##%"#!$&# ! $%#&%! - $%%! $!$ !%)"# *"#!$- 7.4.2. Educational Events and Training $!&$+# #%#!%!%*"!$+($! $%#%! !&$%%$( #&#%!&#$-%$$%%%%!'#6111"!"'$%%!*'!&$%!# !&%& #! $%#&%! -!#%*!%& ($"!% %! &*#$-!*'!&$($$!%$!$!(!&$%%3119& %&#/$ !(-%$$%%%%#!& 7+511"!"'%!&#%!&$&# %$ ! $%#%! "$- 7.4.3. Systems Testing $% !$$! !%& !$&# $*$%$($ "#!#%! $&#%!&$(!"#%$$ -!!( %$%$( "#!#, • # • &% • !#!($ • *$%)%# $%%"#$$&# • &%$#&%#!( • #!"#! &#%! !% ##0!2411(!!&$&# 7.4.4. Monitoring $%.21$#! $%!#"!#%! !&#!%! $ %!&$, • #$%!!##!$%% • #$%!!#$%##!! • ! !!#(! • ! !!# $# D-483 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.5 Project Evaluation %!"!$#"" ! " !#"!!""'" " "$!'!"!%" #"# "! ""'!) ! "" !#"! "!"! '!#"!(% #!&""! ") 7.5.1. Source Energy Savings Requirement: Final production home designs must provide targeted whole house source energy efficiency savings based on BA performance analysis procedures and prior stage energy performance measurements. Conclusion: Pass "!!"""$!# '!$!/,2 """ % '!" "!) '!$!! !"//2%""" . #""$"!'!") "!$!% #"%" *! '#$)-)0),-"-,,1# " !)!!$" #"!!" #"#"' !# "!""'"!'!"!) 7.5.2. Prescriptive-based Code Approval Requirement: Must meet prescriptive or performance safety, health and building code requirements for new homes. Conclusion: Pass "''$# "'"!"-,,." "#) '$#!"!"!#!!! !" #""""'$$ ")#$ ! "'"! "!"# ' !) "! "%'"!# !"$ !! $!& & '!" #") 7.5.3. Quality Control Requirements Requirement: Must define critical design details, construction practices, training, quality assurance, and quality control practices required to successfully implement new systems with production builders and contractors. Conclusion: Pass "# ! $!#"'!!# #"'" " # !" #"!"")!"+!" #" "'' $%!" !!!" #" # !!)% %" ""!# #"'" " #""#"'!" #" "!"" #$ ") ""!&"#"'" "!" "!#) "" "!$ '" %!"!%""!"" !'#" " " !")% "!%! D-484 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House " " "% " % " % 7.5.4. Neutral Cost Target Requirement: The incremental annual cost† of energy improvements, when financed as part of a 30 year mortgage, must be less than or equal to the annual reduction in utility bill costs relative to the BA benchmark house. Conclusion: Pass " "%" #% "% " ""% !')(+,"#"% *("-.% "% Table 7.5-1: Colleyville House Neutral Cost Analysis "$" "" $ *(&"$ D-485 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House !%)""3 ' #"!"$!%#"!!" !%"'$)'!!""#""! # " "'"!"!%!""!""# "$"" "& ") !""##""'!$!% !#""' "! $' "# !-"# !/1)24," (" "'/0)13,.) 7.5.5. Quality Control Integration Requirement: Health, Safety, Durability, Comfort, and Energy related QA, QC, training, and commissioning requirements should be integrated within construction documents, contracts and BA team scopes of work. Conclusion: Pass "# ! $!" "#"'" " ##""!" #" "#!"!# ""#!"! ")!!$" # "# !"#!# "$!!" #""$ #! #!"!)'""#!""!""!"!! "' ) "! """ ""# #"!" ' #""&"#"'!!# ) ! ""& #"!) 7.5.6. Gaps Analysis Requirement: Should include prototype house gaps analysis, lessons learned, and evaluation of major technical and market barriers to achieving the targeted performance level. Conclusion: Pass ""%!"# "!" #"" ! #!%!"'! !#") """""#&" !!#"#""!" "!!!"% )!#!""""!!"% " $"!""!""%!""#"'"!!#")!%! #"$"'$#!#" "%#" !!"! !#"# ""'!) !! """&" !#"!" ! 5+ "1+ ) "!!! # "1+*'!'# " !"!%'"# " #" !!!) D-486 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 7.6 Conclusions/Remarks ""$%"##$"%$408"$$) %#1007$$" "$# &%$#$$ #$&) $$%"$))$ "##'##%""&#"$$$&# + ""$%"##$$")$#$"%$$ "$ $"$!%$)%#$"#+ #%""$)#ɠ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rototype House Evaluations—Greencraft Builders Colleyville House 7.7 Appendices 7.7.1. BSC Project Case Study – Greencraft Colleyville House 7.7.2. Drawings and Specifications 7.7.3. Energy Modeling 7.7.4. Manual J Calculations 7.7.5. Field Testing 7.7.6. Builder’s Challenge Certificate D-488 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.1 BSC Project Case Study—Greencraft Colleyville House 6/2009 Colleyville Eco House Prototype RR-0911: BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 1 Case Study Colleyville Eco House Prototype Colleyville, Texas PROJECT PROFILE OVERVIEW BSC collaborated with Greencraft Builders, LLC in Colleyville, TX on a 2009 prototype house called the Colleyville House. This house demonstrates the energy efficiency and durability upgrades that Greencraft currently promotes in all of their products. The Colleyville house is located in Colleyville, TX, about 25 miles North West of Dallas. The house was designed by William Peck and Associates, an award winning architect specializing in sustainable energy efficient architecture. BSC has been collaborating with Greencraft homes since 2005 and have forged a valuable working relationship. BSC provided consulting services for Greencraft and recommended numerous efficiency and durability improvements. One of the main features that separate this home from previous projects is the inclusion of a high efficiency ground source heat pump. Other key upgrades include an unvented roof with low density spray foam insulation and supplemental dehumidification. Also included are LoE3 next generation spectrally selective glazing treatment Project Team: Greencraft Builders, LLC, Building Science Corporation Address: 1708 Oak Knoll Drive, Colleyville, Texas Description: 4,886 ft2 two-story single family home Completion Date: March, 2009 Estimated Annual Energy Savings: Average 70.5% projected source energy savings relative to the 2008 Building America Benchmark Project Website: http://colleyvilleecohouse.com/ Appendix D.7.7.1 D-490 Colleyville Eco House Prototype RR-0911: BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House BUILDER PROFILE GreenCraft Builders L.L.C. is the culmination of more than 30 years of experience building and remodeling homes in the Dallas/ Fort Worth metroplex. Since 2004, Chris Miles, principal of GreenCraft, has been recognized as a leader in the North Texas green building industry, first as a producer and project manager, and now as a builder with his company, GreenCraft Builders L.L.C. PARTICIPATING PROGRAMS & CERTIFICATIONS U.S. Department of Energy’s Building America Program U.S. Green Building Council LEED® for HomesGold U.S. Environmental Protection Agency ENERGY STAR® Program NAHB National Green Building Program™- Gold 2 PARAMETRIC STUDY and very low enclosure infiltration. A full CFL lighting package plus Energy Star® appliances help to achieve a HERS Index of 36. The Colleyville house was able to procure high quality fiberglass framed windows with state of the art LoE3 spectrally selective glazing coating. This resulted in an NFRC full unit SHGC rating of 0.34 with a U-value of 0.29. This CONSTRUCTION glazing coating, coupled with extensive Greencraft constructs with full Adoverhangs in the floor plan, results in a vanced Framing in their walls, roof, and greatly reduced cooling peak load and frame floor. This includes 2x6 studs annual cooling energy use. at 24” o.c. plus two stud energy corA high efficiency ground source heat ners and single top plates. Greencraft employs stack framing so that wall and pump (18.8 EER/4.1 COP) is installed along with a integrated supplemental floor framing members are aligned to dehumidification. All the equipment and transfer loads efficiently through the ductwork is located in the unvented structure. cathedralized attic to save living space. The wall cavity is fully insulated with Jump ducts provide passive returns low density open cell spray foam to an from the bedrooms. High efficiency R-20. The roof is an unvented catheexhaust ducts are installed at all the dralized roof with R-30 low density bathrooms and at the kitchen hood. open cell spray foam installed to the underside of the roof sheathing. GreenBuilt™ North Texas Sole show house at the Sunbelt Builders Show Appendix D.7.7.1 D-491 Colleyville Eco House Prototype RR-0911: BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House 3 ENCLOSURE DESIGN uRoof Assembly: Unvented roof with R-30 open cell spray foam and fully adhered waterproof membrane vWall Assembly: Fully advanced 1 2 framed structure; R-24 wall with R-20 open cell spray foam and 3/4” XPS sheathing wWindow Specifications: Vinyl framed double glazed windows: U=0.34, SHGC=0.29. xAir Sealing: The design 3 5 4 6 infiltration rate is 2.5 in2 leakage area per 100 ft2 of enclosure area. Low density open cell spray foam installed in wall and roof cavities. Low expanding open cell spray foam installed around windows and mechanical and electrical penetrations throughout the enclosure. Foundation Assembly: Slab-on-grade foundation; y uninsulated with Termimesh® termite mitigation system and sill seal z. MECHANICAL DESIGN Heating and Cooling: 4.1 COP/18.8 EER ground source heat pump (see u for piping). Ventilation: Fantech energy recovery ventilator (ERV) v. Supplemental Dehumidification: GeneralAire whole-house dehumidifier integrated with HVAC system w. DHW: 0.82 EF instantaneous water heater with an add-on storage tank for hot water from ground source heat pump. Lighting: ENERGY STAR® CFLs Appliances: ENERGY STAR® dishwasher, refrigerator and clothes washer. 1 3 2 Appendix D.7.7.1 D-492 Colleyville Eco House Prototype RR-0911: BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House VENTILATION Greencraft Builders, LLC utilizes Central Fan Integrated Supply ventilation that draws outside air via a 6” flex duct to the return plenum of the HVAC system. This allows for the introduction of outside air to the living space whenever space conditioning is already operating. The GeneralAire whole house dehumidifier draws air from the main living space and supplies dehumidified air to the supply plenum of the HVAC system. An Aprilaire® Ventilation Control System 8126 communicates with the air handler to employ fan cycling. Fan cycling will turn on the fan at a 33% duty cycle (10 minutes on, 20 minutes off) in order to provide outside air during periods of no space conditioning. A 6” mechanical damper is installed on the 6” outside air duct. This is controlled by the fan cycler and will close off the outside air duct during periods of consistent space conditioning to prevent over ventilation of the living space. Bathroom exhaust fans plus a kitchen hood are installed to provide spot ventilation when necessary. These are all routed to the outside and are not recirculating fans. One of the bathroom fans is rated to provide ASHRAE 62.2 ventilation so that the house can be operated at that rate if needed. QUALITY CONTROL • Design follows BSC Building America criteria 4 MOVING FORWARD The open house period of the Colleyville house has ended and now Greencraft is ready to start design on the Net Zero Energy Lewisville Eco House. One of the major design upgrades for this house will be the installation of a heat pump with integrated supplemental dehumidification. AAON Inc. has designed a residential heat pump that integrates modulating gas reheat to allow for dehumidification separate from cooling. This technology has been implemented successfully in commercial buildings for years and now will provide supplemental dehumidification in residential buildings. • Manual J8 analysis ensures right sized mechanical systems and ductwork DESIGN AND CONSTRUCTION CHALLENGES The construction of the Colleyville house presented a number of challenges to the builder. First, there was a new framing crew on the site and they had significant difficulty constructing a fully advanced framed structure. Greencraft had to hire another framing contractor halfway through construction to remedy errors and finish the job to meet specifications. Second, the homeowners requested a dark metal roof for aesthetic purposes. Greencraft had to work to find an Energy Star® rated dark metal roofing material in a short period of time. Third, the homeowners also requested a higher roof pitch to match the 10:12 roofs in the neighborhood. A 10:12 roof pitch greatly reduces the overhang potential for shading purposes so Greencraft compromised by increasing the roof pitch from the original 4:12 to 6:12. A 6:12 pitch still allowed for the specified overhangs to be constructed. Fourth, a considerable amount of select fill had to be obtained to prepare the ground surface properly. This was due to the fact that the previous home on this site had a pier and beam foundation. The existing foundation was fully removed and that left large cavities that needed to be filled. Then, the resulting ground had to be compacted 95% to meet the structural demands and this had to be tested and verified in the field. This case study has been prepared by Building Science Corporation for the Department of Energy’s Building America Program, a private/public partnership that develops energy solutions for new and existing homes. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof. For more information about Building America go to www.buildingamerica.gov. For more information about this or other case studies by Building Science Corporation and the Building America Program go to: www.buildingscienceconsulting.com/buildingamerica. Appendix D.7.7.1 D-493 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.2 Drawings and Specifications N 06° 26' 20" W 322.34' N LOT 2, BLOCK 1 EXISTING TREE 10" OAK EXISTING TREE 16" OAK BRICK COLUMN TYP. CONCRETE EXISTING / REMOVED WALKWAY A/C BACK PORCH 9' 37" W 314.92' COURT LOT 1, BLOCK 1 WROUGHT IRON FENCE DEMOLISHED BUILDING REMOVED A/C REMOVED POOL EQUIPMENT EXISTING TREE 40' BUILDING LINE WATER METER WATER METER OAK KNOLL DRIVE SITE PLAN 52'-1/2" BACK PORCH 2 LOT 2 LOT 1, BLOCK A N 88° 07' 30" E 239.63 CHAIN LINK ' TENNIS FENCE UTILITY POLE 15' DRAINAGE & UTILITY EASEMENT OHE EXISTING GABANA EXISTING BUILDING WOOD FENC E GAZEBO UTILITY POLE 6' DRAINAGE & UTILITY EASEMENT CONCRETE POOL WROU GHT IRON FENCE 37'-4 5/8" NEW RESIDENCE 36'-10" 47'-5 1/4 " FRONT PORCH/ ENTRANCE EXISTING TREE APPROXIMATE LIMIT OF 100 YARD FLOOR PLAIN PER GRAPHIC SCALE S 85° 47' 11" W 186.50' CABLE BED. TEL. PED. SANITARY SEWER MANHOLE 1" = 20' SITE PLAN Date: SHEET 1 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS S 03° 0 STONE 102'-5 3/8" 1 6' DRAINAGE & UTILITY EASEMENT 83'-8 3/8" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-001 OF 27 Appendix D.7.7.2 14'-6" 4'-1/8" 3'-3 7/8" 4'-7" 11'-6 1/2" 24'-4 1/2" 5'-6" 4'-5" 5'-9 1/4" 1'-4 1/2" 6'-6" 6'-6" 5'-7 1/4" 3'-1 1/2" 4'-3" 4'-3" 4'-3" 5'-0" 6'-6 1/4" 28'-10" 5 1/2" 10'-2" 3'-7 1/4" 6'-4 7/8" 3'-9 1/8" 2'-5 1/2" 2'-6 1/2" 3'-10" 2'-8 1/4" 10'-10 3/4" 4'-11" 4'-11" 8'-1 1/4" 8'-9" FLAT WORK GRILL AREA 7'-10" 226 OUTDOOR KITCHEN CK SIZE OF EXISTING W117 W118 D118 37'-0" CLG HT 10'-0" D112 122 GARAGE CLG HT 10'-0" D113 D123 10'-0" 121 OFFICE BUILT IN @ OFFICE A105/A 4'-4" @ 42" CLG HT 12'-0" 6'-11" 57'-2 1/2" 6'-5 1/2" 4'-5 1/2" D117 23'-6" 117 PWDR RM CLG HT 10'-0" 20 R. @ 7" 19 T. @ 11" 2'-4" 114 GAMERM D102 101 ENTRANCE HALL CLG HT 12'-0" CLG HT 10'-0" 4'-2 1/2" D116 118 STORAGE 115 BAR CLG HT 12'-0" D120 8'-8" 2'-4" D103 5'-4" 7'-2 1/4" 6'-0" Opening 105 4'-5 1/4" A202/B D124 8'-3 1/2" 3'-10" 4'-9" 3'-10" Opening 108 4'-2 1/2" STRUCTURAL BEAM @ 12' 103 PWDR RM D114 6'-2" DBL OVEN COMBO REF 119 BACK A105/B Sect ENTRANCE D115 HALL CLG HT 10'-0" A107/B 7'-8" DECORATIVE BEAM TO CONTINUE TO SIDE WALL @ 12' CLG HT 12'-0" 4'-7 1/2" 7'-1" 2'-2" 16'-5" BEAM @ 10' 4'-1 1/2" 6'-2 1/2" 4'-6" KITCHEN ELEV. A401 A107/A 4'-10 7/8" 4'-8" D119 W127 W126 W125 W138 W137 D121 W132 9'-7 1/2" 11" D101 W139 16'-6" 5'-4 1/2" W103 116 MEDIA/MUSIC ROOM CLG HT 10'-0" 11'-8" W101 6'-3" W102 16'-0" @ 36" D122 2'-1 7/8" 1'-9" D111 220 PANTRY/ UTILITY CLG HT 10'-0" 12'-5 1/2" 7'-2 3/4" 9'-10" D 2'-4" 113 KITCHEN CLG HT 12'-0" 13'-9 3/4" 102 HALL 104 HIDE CLOS. Opening 106 CLG HT 10'-0" HIDDEN 24'-10 1/4" 11'-5" L.C. UP W104 4'-1 1/8" BEAM @ 12' 6'-1/2" 6'-11 5/8" 6'-2 1/2" 5'-10" 3'-8" D106 108 SHOWER CLG HT 10'-0" D125 8'-6 5/8" STORAGE 14'-4 1/2" 2'-0" W119 2'-3 3/4" 2'-0" 1'-0" FUTURE ELEVATOR & HALLWAY W 9'-6" A106/B D104 W+D 110 MASTER CLOSET CLG HT 10'-0" 12'-0" 4'-5/8" 4'-5/8" 4'-6" 109 TOILET RM CLG HT 10'-0" 8'-5/8" D108 3'-0" 6'-3 5 /8" W121 IRON BD D.W. BEAMS @ 14'-7" 5'-2" D107 4'-0" LINEN W10 5 W120 DRAWER MICRO D105 W106 5'-2 1/4" 8" 4'-0" U.C. REF U.C. REF 5'-9 3/4" 11'-0" 8'-0" 106 MASTER BATHRM CLG HT 10'-0" 1'-6 5/8 " FULL HT CABINET W/ COFFEE MAKER D.W. 4'-0" CLG HT 14'-0" CLG HT 12'-0" A106/A 11'-3" 1'-4" 111 GREAT RM 6'-1" 20'-6" 17'-5 7/8" 6'-4" 5'-11" ARCHED TOWER 57'-2 1/2" CLG HT 12'-0" OR ARCHED TOWER CLG Opening 107 TUB A201/B W114 2'-8 1/4" 105 MASTER BEDRM CLG HT 12'-0" 107 TUB CLG HT 10'-0" W113 7'-5 3/8" W112 20'-3 1/2" 3'-8 1/2" W107 112 DINING RM 8'-4" W111 225 COVERED PORCH 2 CLG HT 10'-0" 14'-10" 3'-11 3/4" D110 D109 11'-5 3/4" W116 8'-4" W110 W124 2'-11" 2'-6" 4" VAULTED CLG W109 W115 7'-5 1/2" 224 BACK PORCH 1 6'-8" 4'-2" W108 5 1/2" 6'-1/2" 1'-6" W123 5 1/2" 17'-3 5/8" 22'-2 7/8" W122 1'-11 1/2" 2'-11" 26'-2" SLAB 2'-7 1/8" 5 1/2" 1'-6" 4" 6'-1/2" 5 1/2" 20'-3 3/4" 5'-9 7/8" METAL SHEET TOP OF OPENING 13'-8 1/2" METAL SHEET TOP OF OPENING 1'-6" 3'-5 1/8" 5 1/2" 5 1/2" 5'-6 1/8" 3'-11 1/8" 1'-9 7/8" 1'-6" 5'-9" 5 1/2" 10" 6'-8" 11'-0" 4'-4" 10'-11" W129 W128 5 1/2" W130 1'-3 1/2" 2'-6" W131 2'-0" 20'-2" WALKWAY 4'-11 3/4" 5'-0" 5'-10" 11'-7" Opening 104 5 1/2" Opening 101 METAL SHEET TOP OF OPENING 5'-5 7/8" W136 A 401/E12 10" WIDE WOOD BEAM W133 3'-5 3/8" 10'-10 3/4" W134 7'-9" Opening 103 8'-10" 6'-4 1/2" 223 FRONT PORCH CLG HT 12'-6 " 2'-5 1/2" 9'-3 1/2" Opening 102 2'-5 1/2" 8'-10" 5 1/2" W135 METAL SHEET TOP OF OPENING 6'-4 1/2" METAL SHEET TOP OF OPENING 3'-10" METAL SHEET TOP OF OPENING 2'-4" 2'-0" 9'-11 3/4" 4'-4" 4'-4" 4'-5 3/8" 2'-8 1/2" 3'-7" 3'-7" 18'-2" 3'-6 1/4" 4'-4" 9'-5 3/4" 17'-4" 20'-2" 7'-2" 2'-5 3/4" 4'-4" 3'-6 1/4" 5'-7 3/4" 4'-11" 4'-11" 7'-10 1/2" 10'-4" 27'-8" 23'-4 1/4" 5 1/2" 119'-4" A 201/A Front SOUTH A FLOOR PLAN 1ST FLOOR 1/4" = 1'-0" 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. 19'-5 3/4" (972) 221-1424 38'-10 1/2" Lewisville, Tx 7'-4" A S S O C I A T E S I N C. ARCHITECTS 10" ARNETT HOUSE 5 1/2" WILLIAM PECK & 119'-4" These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED A202/A Back NORTH REVISIONS 1st FLOOR PLAN AREA SQUARE FOOTAGES: 1ST FLOOR: 3,452 2ND FLOOR: 1,336 3RD FLOOR: 97 TOTAL A/C: 4,885 GARAGE: 1,040 FRONT PORCH+ENTRANCE: 253 BACK PORCH 1: 177 COVERED PORCH 2 :342 BALCONY: 326 UNCOVERED OUTDOOR KITCHEN: 70 THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House DATE Date: 05-23-08 Scale: Drawn: Job: Sheet Number: A-101 SHEET 2 OF 27 Appendix D.7.7.2 4'-4" A FLOOR PLAN 2ND FLOOR 2'-2" 8'-6" 201 KIDS STUDY 202 D202 STUDY CLOSET W216 4'-8" 9'-1 3/4" 2'-3 3/4" FUTURE ELEVATOR 6'-11" A105/B Sect D203 212 PWDR RM W215 W214 3'-9 1/4" W213 2'-2 3/4" 2'-5 1/4" 6'-0" 3'-3/8" 5'-5 1/2" 4'-8" W212 3'-7" 12'-10 1/2" 6'-4" D210 207 BEDRM 3 4'-5 1/2" 13'-4" D206 DESK 211 BATHRM 3 CLG HT 9'-1 1/2" 206 WC D208 208 CLOSET DN 210 BEDRM 4 209 CLOSET 2'-0" 2'-10" 1/4" = 1'-11 1/2" 1'-10 1/2" 3'-4 1/2" 5'-3" 47'-5 3/4" 26'-2" 5'-10" 4'-3 1/4" W205 A202/B W211 4'-7 1/2" 5'-6" 47'-5 3/4" 1'-0" 2nd FLOOR PLAN Date: SHEET 3 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 3'-8" LINEN 36'-1/2" 3'-0" 1'-8" 3'-6" 205 BATH 2 W206 SHOWER 12'-4" 4'-0" 1'-6 3/4" 6'-2" 204 VANITY RM W207 21'-10 1/4" D214 W204 6'-0" D212 D213 OPEN BALCONY 1'-11 1/2" W209 2'-1" 213 CLOSET / 5'-6 1/2" 4'-1" 2'-3" D215 5'-7" W203 2'-1" LADDER 6'-4" W208 214 1/2 OPEN AND 1/2 COVERED BALCONY 203 BEDRM 2 5'-3 1/2" 1'-9" 7'-6" 6'-8" 20'-7 1/4" 6'-6" D209 W202 2'-8 5/8" 12'-10" 4'-7" A107/B 2'-11 7/8" 5'-1" 20'-3 3/4" 11 1/2" 21'-3 3/4" W210 A107/A D201 4'-6 1/2" A105/C D211 5'-8 1/2" 19'-1 3/4" D207 A105/A 14'-4 1/2" CLG 9'-1 1/2" 12'-10" 2'-2" 5'-4 1/2" D205 1'-6 1/2" 5'-4 1/2" D204 OPEN TO MASTER BEDRM 14'-5 1/2" W201 1'-10" A106/B 6" 1'-0" 6'-4" OPEN TO GREAT RM L.C. 14'-3 1/2" 8'-0" 14'-4 1/2" 1'-6" 4'-0" 2'-6" 2'-3" 15'-9 3/8" 2'-3" 5'-5" 20 R. @ 7" . @ 119 T 2'-2" 1" A106/A 5'-7" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-102 OF 27 Appendix D.7.7.2 A W304 A106/A 3'-0" 3'-1" 13'-4 7/8" 1'-3" 41'-6 3/4" 3'-5" A105/A W304 A107/A 3'-3" FLOOR PLAN ROOF 3'-8" W303 301 OBSERVATORIO W301 A107/B 4'-0" 10'-4 1/4" W302 3'-4 1/8" OPEN TO MASTER BEDRM W302 CHIMNEY 12'-3 1/2" 3'-1" W305 3'-8" W305 2'-8" 3'-4 1/8" A202/A Back NORTH 119'-4" 10'-6" 36'-11 3/4" W301 3'-10" 2'-10" FIRST FLOOR EXTERIOR WALLS SECOND FLOOR EXTERIOR WALLS 10'-6" 3'-5" W303 LADDER A106/B A105/B Sect A202/B 3'-3" 10'-6" SECOND FLOOR EXTERIOR WALLS FIRST FLOOR EXTERIOR WALLS A 201/A Front SOUTH 1/4" = 1'-0" ROOF Date: SHEET 4 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 16'-5 1/2" A201/B 3'-6" 3'-2 1/2" 10'-1/2" 2'-10" 3'-3" 10'-4 1/4" 5'-2" 3'-2 1/2" 9'-2" 4'-0" 9'-2" 11'-4 1/2" 19'-6 1/2" 21'-8 1/4" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-103 OF 27 Appendix D.7.7.2 SGL DBL DBL DBL DBL DBL --------------- --------------- --------------- --------------- B --------------- --------------- --------------- --------------- --------------- --------------- --------------- DOUBLE DOOR UNIT W/TRANSOM 1'-5" COAT CLOSET POWDER ROOM MASTER BEDRM BATHRM DBL DOOR TOILETRM MASTER CLOSET SHOWER SLIDING D FAMILY RM DBL DOOR PORCH D W/TRANSOM 1'-5" BACK HALL DOOR PANTRY/UTILITY POCKET D OFFICE DOOR PANTRY D UNDER STAIRS CLOSET BATHRM DOOR HALLWAY GARAGE INT DOOR PORCH D TO GARAGE MEDIA RM INT DOOR MEDIA RM INT DOOR FRONT PORCH GLASS DOOR CLOSET DOOR GARAGE D W/TRANSOM O.H. GARAGE D O.H. GARAGE D BALCONY DOOR CLOSET DOOR BATHRM DOOR BATHRM DOOR BATHRM DOOR BEDRM DOOR CLOSET DOOR CLOSET DOOR BEDRM DOOR BEDRM DOOR CLOSET DOOR BATHRM DOOR TOILET RM DOOR SHOWER RM DOOR BATHRM DOOR --------------- DOOR SCHEDULE WINDOW SCHEDULE MARK A Quantity Library Part Name SIZE WIDTH HEIGHT HEADER HT MATERIAL GENERAL NOTES: Opening 108 W101 W102 1 1 1 W Rectangular Open... W1 Casement W1 Casement 12'-0" 2'-0" 2'-0" 6'-0" 3'-6" 3'-6" 10'-0" 8'-8" 8'-8" Wood 08-Pine ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW --POWDER RM W/O MULLION POWDER RM W/O MULLION W103 W104 W105 W106 W107 W108 W109 W110 W111 W112 W113 W114 W115 W116 W117 W118 W119 W120 W121 W122 W123 W124 W125 W126 W127 W128 W129 W130 W131 W132 W133 W134 W135 W136 W137 W138 W139 W201 W202 W203 W204 W205 W206 W207 W208 W209 W210 W211 W212 W213 W214 W215 W216 W301 W302 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 W1 Casement W1 Casement W1 Casement W1 Casement W Fixed W1 Casement W1 Casement W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W1 Casement W1 Casement W1 Casement W Awning 1 W Awning 1 W Awning 1 W Awning 1 W Awning 1 W Awning 1 W1 Casement W1 Casement W1 Casement W1 Casement W1 Casement W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W Fixed W1 Casement W1 Casement W1 Casement W Awning 1 W Awning 1 W Awning 1 W Awning 1 W1 Casement W Awning 1 W Awning 1 W1 Casement W1 Casement W Awning 1 W Awning 1 W Awning 1 W Awning 1 W1 Casement W1 Casement 2'-0" 2'-0" 2'-0" 2'-0" 4'-0" 3'-6" 3'-6" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 3'-6" 3'-6" 3'-6" 3'-6" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 2'-0" 2'-0" 2'-0" 2'-0" 3'-0" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 4'-0" 4'-0" 3'-0" 2'-6" 2'-6" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-6" 3'-0" 3'-6" 3'-6" 3'-6" 3'-6" 4'-6" 6'-9" 6'-9" 6'-6" 6'-6" 3'-0" 3'-0" 3'-0" 6'-6" 6'-6" 6'-6" 6'-6" 6'-0" 5'-0" 5'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 3'-6" 3'-6" 3'-6" 3'-6" 5'-0" 6'-6" 6'-6" 6'-6" 1'-6" 1'-6" 1'-6" 1'-6" 6'-0" 6'-0" 5'-6" 2'-0" 2'-0" 2'-0" 2'-0" 5'-6" 2'-0" 2'-0" 5'-6" 5'-6" 2'-0" 2'-0" 2'-0" 2'-0" 2'-6" 5'-6" 8'-8" 8'-8" 8'-8" 8'-8" 8'-6" 9'-3" 9'-3" 8'-0" 8'-0" 12'-0" 12'-0" 12'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-4" 8'-4" 8'-4" 8'-5" 8'-5" 8'-5" 8'-5" 8'-5" 8'-5" 8'-8" 8'-8" 8'-8" 8'-8" 8'-6" 8'-0" 8'-0" 8'-0" 10'-6" 10'-6" 10'-6" 10'-6" 8'-0" 8'-0" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 7'-8" 6'-6" 6'-6" ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW POWDER RM W/O MULLION POWDER RM W/O MULLION POWDER RM W/O MULLION POWDER RM W/O MULLION MASTER TUB MASTER BEDRM WINDOW MASTER BEDRM WINDOW DINING RM DINING RM GREAT RM GREAT RM GREAT RM DINING RM DINING RM DINING RM DINING RM DINING RM PANTRY/UTILITY PANTRY/UTILITY W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION POWDER RM W/O MULLION POWDER RM W/O MULLION POWDER RM W/O MULLION POWDER RM W/O MULLION HIDDEN CLOSET W/O MULLION DINING RM DINING RM DINING RM DINING RM DINING RM DINING RM DINING RM STUDY RM STUDY RM BEDRM W W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION BEDRM W W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION BEDRM W BEDRM W W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION W/ 1 VERTICAL MULLION OBSERVATORIO BEDRM W W303 W304 W305 2 2 2 W1 Casement W Fixed W1 Casement 3'-0" 2'-6" 3'-0" 3'-6" 1'-6" 3'-0" 6'-8" 7'-10" 7'-8" ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW ALU CLAD. WOOD WINDOW OBSERVATORIO BEDRM TOWER, HEADER TO 1ST FLOOR 19'-10" REMOTE CONTROL, HEADER HT 19'-8" TO 1ST FLOOR WINDOW SCHEDULE 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. DBL (972) 221-1424 GLASS HOLLOW SOLID SOLID SOLID SOLID HOLLOW GLASS GLASS GLASS GLASS SOLID SOLID HOLLOW HOLLOW SOLID SOLID SOLID SOLID SOLID GLASS HOLLOW SOLID METAL METAL GLASS HOLLOW SOLID SOLID SOLID SOLID HOLLOW HOLLOW SOLID SOLID HOLLOW SOLID SOLID SOLID SOLID --------------- Lewisville, Tx 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 4'-6" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 6'-8" 8'-0" 8'-0" 8'-0" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 10'-8" 10'-0" 10'-0" 8'-6" 8'-0" 6'-8" 8'-0" NOTES A S S O C I A T E S I N C. ARCHITECTS ROOM FINISH SCHEDULE 6'-0" 3'-0" 2'-6" 3'-0" 3'-0" 3'-0" 3'-0" 2'-6" 6'-0" 3'-0" 3'-0" 3'-0" 3'-0" 2'-8" 2'-8" 2'-8" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 3'-0" 9'-0" 18'-0" 3'-0" 2'-6" 2'-6" 2'-6" 2'-6" 3'-0" 2'-4" 2'-4" 3'-0" 3'-0" 2'-4" 2'-6" 2'-4" 2'-4" 2'-6" 8'-0" 5'-5 1/2" 5'-5 1/2" 3'-4 1/2" 3'-0" 2'-0" 5'-4" LOUVER MATL W HT GLZ ARNETT HOUSE C HT EL WILLIAM PECK & D101 D102 D103 D104 D105 D106 D107 D108 D109 D110 D111 D112 D113 D114 D115 D116 D117 D118 D119 D120 D121 D122 D123 D124 D125 D201 D202 D203 D204 D205 D206 D207 D208 D209 D210 D211 D212 D213 D214 D215 Opening 101 Opening 102 Opening 103 Opening 104 Opening 105 Opening 106 Opening 107 W TYPE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED SIZE MARK REVISIONS DATE SCHEDULES DOOR DOOR AND FRAME SCHEDULE FRAME HARDWARE FIRE RATING EL GLZ HEAD SET NO KEYS. RM NO THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Date: 05-23-08 Scale: Drawn: Job: Sheet Number: A-104 SHEET 5 OF 27 Appendix D.7.7.2 A A105/C 12' 1'-5" C 12'-0" 13'-5" COLUMN KID'S STUDY 11'-7" 0" 0" 1/4" = 10' 1'-0" B 0" A105/A A105/B PANTRY/ UTILITY 0" 1'-6 1/2" OBSERVATORIO TOWER 21'-7" LADDERS TO OBSERVATORIO TOWER 16'-6" KID'S STUDY BALCONY 11'-5 1/2" L.C. UTILITY COVERED PORCH UNDER STAIR STORAGE -1 1/2" 1/4" = 1/4" = 1'-0" 29'-7" 25'-1" 21'-7" LOFT LOUNDRY 11'-7" KITCHEN OFFICE 0" 1'-0" SECTIONS Date: SHEET 6 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 3'-6" 5'-1/2" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-105 OF 27 Appendix D.7.7.2 B A A106/B A106/A 12'-0" 1'-5" KITCHEN CLG 12'-0" 13'-5" GREAT RM CLG STONE UP TO 14' GAMERM CLG 0" -1 1/2" 1/4" = 1/4" = 1'-0" TOWER BEAMS ACROSS TOWER FAN 5'-3" MASTER BEDRM 2'-6" 1'-0" SECTIONS Date: SHEET 7 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 14'-7" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-106 OF 27 Appendix D.7.7.2 BALCONY B A 9'-0" 9'-1 1/2" KID'S STUDY 11'-5 1/2" COVERED PORCH 3'-4" UTILITY -1 1/2" 0" A107/B A107/A 1/4" = 1/4" = 1'-0" 1'-0" 8'-0" SECTIONS Date: SHEET 8 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 1'-0" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-107 OF 27 Appendix D.7.7.2 29'-7" TOP OF PLATE STUCCO 21' TOP OF PLATE STUCCO 13'-5" TOP OF PLATE 14' TOP OF PLATE STUCCO STONE 0" 2 10'-8 1/2" 1 A 201/B Left 29'-7" TOP OF PLATE 10'-6" 5'-3" 0" A 201/A Front 1/4" = 21' TOP OF PLATE 13'-1/2" TOP OF PLATE @ BAR 10'-6" TOP OF PLATE 1/4" = 1'-0" STUCCO STANDING SEAM METAL ROOF 20'-7" TOP OF PLATE STUCCO 14' TOP OF PLATE ALUMNUM CLAD WOOD WINDOWS 12' TOP OF PLATE @CENTER OF BEAM 10'-11 1/2" TOP OF PLATE 10'-6" TOP OF PLATE 6'-4" 5'-3" 3'-6" 0" 1'-0" FRONT& LEFT ELEVATIONS Date: SHEET 9 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-201 OF 27 Appendix D.7.7.2 29'-7" TOP OF PLATE STUCCO 21' TOP OF PLATE 16'-9" CAST STONE CAP 14' TOP OF PLATE 11'-7" 1 STUCCO 12' TOP OF PLATE 10'-6" TOP OF PLATE STANDING SEAM METAL ROOF STUCCO STONE 0" 2 A 202/B Right 12' TOP OF PLATE 6'-4" 5'-3" 0" F.F. -1 1/2" A 202/A Back 0" F.F. 1/4" = 20'-7" TOP OF PLATE 13'-5" TOP OF PLATE 10'-6" TOP OF PLATE 10'-11 1/2" TOP OF PLATE STUCCO 5'-3" STONE 0" 1/4" = 1'-0" 29'-7" TOP OF PLATE STUCCO 21' TOP OF PLATE ALUMNUM CLAD WOOD WINDOWS 16'-9" STUCCO STANDING SEAM METAL ROOF 12'-4" 10'-8 1/2" 1'-0" NORTH & EAST ELEVATIONS Date: SHEET 10 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-202 OF 27 Appendix D.7.7.2 1 ROOF NOTES: ALL RAFTERS TO BE 2x8 @ 24" O.C., #U.N.O. ROOF SLOPES TO BE: - MAIN ROOFS 4' : 12' - ROOF PLAN PLATE HT 10'-8 1/2" PLATE HT 14'-9" PLATE HT 10'-6" 4 : 12 4 : 12 TOWER PLATE HT 21'-0" 4 : 12 4 : 12 4 : 12 4 : 12 4 : 12 PLATE HT 10'-0" 4 : 12 PLATE HT 20'-7" PLATE HT 12'-0" PLATE HT 20'-7" 4 : 12 TOWER PLATE HT 29'-7" 4 : 12 4 : 12 TOWER PLATE HT 29'-7" PLATE HT 20'-7" PLATE HT 10'-6" PLATE HT 13'-1/2" 4 : 12 4 : 12 PLATE HT 20'-7" PLATE HT 13'-5" 3'-6" : 12' 3'-6" : 12' PLATE HT 13'-5" PLATE HT 10'-6" 4 : 12 PLATE HT 20'-7" 4 : 12 PLATE HT 13'-5" (MASTER BEDRM) TOWER PLATE HT 21'-0" 4 : 12 TOWER PLATE HT 29'-7" TOWER PLATE HT 29'-7" 4 : 12 PLATE HT 20'-7" 4 : 12 PLATE HT 10'-6" PLATE HT 12'-0" @ CENTER OF BEAM PLATE HT 10'-6" OVERHANG TO BE MIN. 2'-2" FROM EXTERIOR FACE OF THE STUD. 4 : 12 ARROWS INDICATE DRAINAGE. 3/16" = 1'-0" ROOF PLAN Date: SHEET 11 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 4 : 12 4 : 12 PLATE HT 12'-0" PLATE HT 10'-6" 4 : 12 4 : 12 4 : 12 TOWER PLATE HT 21'-0" 4 : 12 4 : 12 TOWER PLATE HT 21'-0" PLATE HT 13'-5" 4 : 12 PLATE HT 14'-0" 4 : 12 PLATE HT 10'-0" 4 : 12 PLATE HT 10'-11 1/2" 4 : 12 4 : 12 4 : 12 PLATE HT 10'-8 1/2" PLATE HT 10'-6" PLATE HT 14'-0" PLATE HT 11'-1/2" PLATE HT 10'-0" PLATE HT 10'-11 1/2" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-301 OF 27 Appendix D.7.7.2 ARCHED ROOF CHIMNEY, ARCHED METAL ROOF 1 ARCHED ROOF Roof Framing 3/16" = 1'-0" Roof Framing Date: SHEET 12 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-302 OF 27 Appendix D.7.7.2 2x6 @16" O.C. 2x8 @16" O.C. 2x6 @16" O.C. TOWER OPEN TO ROOF DECK (ARCHED). 2x6 @16" O.C. 2x6 @16" O.C. 2 2x6 @16" O.C. 2x6 @16" O.C. 1 OPEN TO ROOF DECK (ARCHED). BEAMS @ 14'-7" 2x6 @16" O.C. 2x8 @16" O.C. 2x8 @16" O.C. 2x8 @24" O.C. ATTIC ACCESS METAL SHEET TOP OF OPENING METAL SHEET TOP OF OPENING 2x8 @16" O.C. BEAM @ 12' 2x8 @16" O.C. Ceiling Joists 1st Floor 2x6 @16" O.C. 2x8 @16" O.C. 2x6 @16" O.C. 2x6 @16" O.C. DASHED LINES: FUTURE ELEVATOR 2x6 @16" O.C. 2x6 @16" O.C. 2x8 @16" O.C. ENGINEERED FLOOR TRUSS SYSTEM ATTIC ACCESS 2x8 @16" O.C. 2x6 @16" O.C. 2x6 @16" O.C. 2x8 @16" O.C. 2x6 @16" O.C. 2x6 @16" O.C. ATTIC ACCESS Ceiling Joists 2nd Floor 1/8" = ENGINEERED FLOOR TRUSS SYSTEM 1/8" = 1'-0" METAL SHEET TOP OF OPENING METAL SHEET TOP OF OPENING VAULTED ENGINEERED FLOOR TRUSS SYSTEM DASHED LINES: FUTURE ELEVATOR 2x8 @16" O.C. (2x6 @24" O.C.) ENGINEERED FLOOR TRUSS SYSTEM BEAM @ 10' DECORATIVE BEAM TO CONTINUE TO SIDE WALL @ 12' STRUCTURAL BEAM @ 12' 2x8 @16" O.C. STAIRS 2x8 @16" O.C. 2x8 @16" O.C. METAL SHEET TOP OF OPENING 2x8 @24" O.C. 10" WIDE WOOD BEAM METAL SHEET TOP OF OPENING 1'-0" CEILING JOISTS Date: SHEET 13 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-303 OF 27 Appendix D.7.7.2 2'-11 1/2" 1 4 4'-1" 11" 3" 4'-0" 3" 1'-9 1/2" 2'-0" 1'-0" 2'-7" 11'-0" 2'-0" MICRO IN DRAWER A 401/E KITCHEN ISLAND ELEVATION 2'-0" A 401/B KITCHEN ELEVATION 2'-0" BUILT-IN COFFEE MAKER DRAWER FULL HT CABINET W/ PULL-OUT DRAWERS 2'-6" 3/8" = 2'-0" 1'-10" 1'-0" 3" 3/8" = 1'-0" 7 2" 2" 2'-2" 2'-0" 1'-4 1/8" 3'-9" 3" 2'-0" 3'-0" 2 1'-0" 9'-5" 3'-4" 2'-0" 3" 3" 3'-0" 6" U.C. REF. UNDER COUNTER REF. SGL DOOR, CURVED WALL BEHIND 3X DBL DOOR CABINETS W/ SHELVES 12" DEEP 3" 3'-6" 3 4'-0" 11'-6" CORNER CAB. CUVED WALL BEHIND 3'-6" 5" 5" 2'-0" 1'-9" 11'-6" A 401/C KITCHEN & BAR 3" A 401/D KITCHEN ELEVATION 2'-0" 2'-0" 3/8" = 2'-0" 2'-0" 2" 3/8" = 3/8" = 1'-0" DBL DOOR WALL CAB. DBL DOOR WALL CAB. 6'-0" 4 1/2" 4'-1" 1'-11" 7'-10" 1'-0" BAR COUNTER 4'-0" 4'-0" 23'-9 1/8" 1'-0" INTERIOR DETAILS Date: SHEET 14 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 1 1/2" 3/8" = 5" 5" SGL DOOR CAB. 7" MICRO IN DRAWER A 401/F KITCHEN & BAR 7" SGL DOOR CAB. 7" DBL DRAWER 3'-6" 3'-8" 3 1/2" COVER PANEL 1'-6" 8'-0" DEEP CABINET W/ SHELVES 1 1/2" 5 2'-7" 1'-0" 3 1/2" 2'-0" 9" 3'-6" 2'-7" 3/8" = 3'-0" A 401/G BAR 10'-0" 6 1'-4" 11" 3'-6" SGL DOOR CAB. 3'-8" 11" 3'-0" DBL DOOR CAB. 3'-0" 12'-0" 2'-0" 9" 9'-0" 6'-0" 3'-6" SGL DOOR CAB. 3'-0" 3'-0" 1'-0" 3'-0" BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: A-401 OF 27 Appendix D.7.7.2 UNIT Ground Fault Interupter-120V Receptacle Recessed Can Light Fixture 220V Receptacle Recessed Can Light Fixture (spot light) Incandescent Pendant Light Fixture GAS 3 4 220 J Gas Supply Junction Box - 10'-0" Above Finished Floor 10'-0" AFF H.B. Floor Outlet Wall Mounted Incandescant Fixture Switch Incandescant Wall Sconce T Thermostat Control 4-Way Switch Flourescent Light Fixture S Smoke Detector 3-Way Switch Condensing and Air Handling Units Hose Bib Bath Exhaust Fan - Broan Model 686 Ductless SD 1x4 Flourescent Light Fixture Garbage Disposal Electrical Panel D.B. Door Bell Exit Sign Telephone Outlet Emergency Egress Lighting DATA+TEL Outlet 2x4 Flourescent Ceiling Tray Light Fixture TV TV Outlet GAS Garage Door Opener 2x2 Flourescent Ceiling Tray Light Fixture Garage Door Opener GENERAL NOTES: PROVIDE FOR FOR MECHANICAL SYSTEM. Vertical Flourescent Lighting CK SIZE OF EXISTING TANKLESS GAS WATER HEATER GAS METAL SHEET TOP OF OPENING CCTV CCTV H.B. METAL SHEET TOP OF OPENING 4 4 @ 96" EAVES FAN CCTV 4 H.B. TANKLESS GAS WATER HEATER FAN TV 4 FAN UP-LT W/DIMMER @ 13' FULL HT CABINET W/ COFFEE MAKER L.C. TV IRON BD W UP-LT W/DIMMER @ 13' IRON BOARD U.C. LTS @ SHELVES WHIRLPOOL 3 4 U.C. LTS @ SHELVES D 220 GAS D.W. TV FAN 4 BUILT IN @ OFFICE GAS GAS FAN D.W. CENTRAL VAC DRAWER MICRO 4 3 BEAMS @ 14'-7" FAN 4 TV W+D 220 S S SD 4 DECORATIVE BEAM TO CONTINUE TO SIDE WALL @ 12' DN -LTS ON TOP OF ARCH REF 4 4 3 TV BEAM @ 10' 220 3 BEAM @ 12' DBL OVEN COMBO SD STRUCTURAL BEAM @ 12' S TIMER FOR BACK YARD LANDSCAPING TIMER FOR FRONT YARD LANDSCAPING SD 20 R. @ 7" 19 T. @ 11" 4 3 4 LTS @ 42" TV FAN U.C. REF U.C. REF 3 UP 48" SPRINKLER 4 3 4 IRON BOARD 3 3 3 3 MTR CLG OUTLET @ 36" 33 OUTLET @ SOFFIT 33 TV LTS H.B. CLG OUTLET TIMER / MOTION ACTIVATED / SWICTH IN GARAGE METAL SHEET TOP OF OPENING METAL SHEET TOP OF OPENING METAL SHEET TOP OF OPENING FAN LTS OUTLET @ SOFFIT LTS 10" WIDE WOOD BEAM OUTLET @ SOFFIT METAL SHEET TOP OF OPENING 1 Electrical Plan 1st Floor 1/4" = 1'-0" 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. GFI (972) 221-1424 Supply Diffuser Lewisville, Tx Built-In Column Accent Lighting W.P. A S S O C I A T E S I N C. ARCHITECTS Monopoint Directional Fixture Return Air Filter Grill ARNETT HOUSE Exterior Flood Lighting WILLIAM PECK & 120V Receptacle Water Proof Incandescent Pendant Light Fixture These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED 120V Receptacle LEGEND REVISIONS ELECTRICAL/1 FIXTURE THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Date: DATE 05-23-08 Scale: Drawn: Job: Sheet Number: E-01 SHEET 19 OF 27 Appendix D.7.7.2 120V Receptacle Water Proof GFI 220 1 3-Way Switch 1x4 Flourescent Light Fixture Garbage Disposal Garage Door Opener Garage Door Opener Vertical Flourescent Lighting LEGEND GAS Exterior Flood Lighting Monopoint Directional Fixture Built-In Column Accent Lighting Ground Fault Interupter-120V Receptacle Recessed Can Light Fixture Incandescent Pendant Light Fixture 220V Receptacle Recessed Can Light Fixture (spot light) J 10'-0" AFF Floor Outlet Wall Mounted Incandescant Fixture Switch Incandescant Wall Sconce T Thermostat Control 4-Way Switch Flourescent Light Fixture S Smoke Detector SD Return Air Filter Grill Supply Diffuser UNIT H.B. Bath Exhaust Fan - Broan Model 686 Ductless D.B. TV Condensing and Air Handling Units Junction Box - 10'-0" Above Finished Floor Gas Supply Hose Bib Electrical Panel Door Bell Exit Sign Telephone Outlet 2x4 Flourescent Ceiling Tray Light Fixture Emergency Egress Lighting DATA+TEL Outlet 2x2 Flourescent Ceiling Tray Light Fixture TV Outlet GENERAL NOTES: PROVIDE FOR FOR MECHANICAL SYSTEM. OPEN BALCONY CLG 9'-1 1/2" TV FAN 3 TV S TV S 43 Electrical Plan 2nd Floor SD CCTV S SD S 4 SD SD STAIR LTS W/MOTION S. TV 1/4" = 1'-0" DN ELECTRICAL/2 Date: SHEET 20 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS 3 W.P. Incandescent Pendant Light Fixture 3 3 4 4 120V Receptacle 20 R. @ 7" . @ 119 T FIXTURE 1" 3 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: E-02 OF 27 Appendix D.7.7.2 3 4 FIXTURE 120V Receptacle 120V Receptacle Water Proof GFI 220 1 3-Way Switch 1x4 Flourescent Light Fixture Garbage Disposal Garage Door Opener Garage Door Opener Vertical Flourescent Lighting LEGEND W.P. GAS Incandescent Pendant Light Fixture Exterior Flood Lighting Monopoint Directional Fixture Built-In Column Accent Lighting Ground Fault Interupter-120V Receptacle Recessed Can Light Fixture Incandescent Pendant Light Fixture 220V Receptacle Recessed Can Light Fixture (spot light) Floor Outlet Wall Mounted Incandescant Fixture Switch Incandescant Wall Sconce T Thermostat Control 4-Way Switch Flourescent Light Fixture S Smoke Detector J 10'-0" AFF SD Return Air Filter Grill Supply Diffuser UNIT Bath Exhaust Fan - Broan Model 686 Ductless H.B. D.B. TV Condensing and Air Handling Units Junction Box - 10'-0" Above Finished Floor Gas Supply Hose Bib Electrical Panel Door Bell Exit Sign Telephone Outlet 2x4 Flourescent Ceiling Tray Light Fixture Emergency Egress Lighting DATA+TEL Outlet 2x2 Flourescent Ceiling Tray Light Fixture TV Outlet GENERAL NOTES: PROVIDE FOR FOR MECHANICAL SYSTEM. FIRST FLOOR EXTERIOR WALLS SECOND FLOOR EXTERIOR WALLS SECOND FLOOR EXTERIOR WALLS FIRST FLOOR EXTERIOR WALLS Electrical Plan Roof Floor 1/4" = 1'-0" Electrical Tower Date: SHEET 21 Lewisville, Tx (972) 221-1424 A S S O C I A T E S I N C. ARCHITECTS WILLIAM PECK & 1708 OAK KNOLL DRIVE, COLLEYVILLE, TEXAS. ARNETT HOUSE These plans are intended to provide the basic construction information necessary to substantially complete this structure. These construction documents must be verified and checked by the builder or person in authority of this project. Any discrepancy, error, and/ or omissions, if any, are to be brought to the attention of the Designer prior to any construction or purchases being made. It is recommended that the owner or builder obtain complete engineering services for: foundation, HVAC, and structural, prior to construction of any kind. NOTE: All Federal, state, and Local codes, ordinances, and restrictions take precedence over any part of these construction documents which may conflict with same, and must be strictly obeyed and followed before and during construction. THESE CONSTRUCTION DOCUMENTS AND THERE USE, ARE THE PROPERTY OF WILLIAM PECK & ASSOCIATES, INC. AND ARE NOT TO BE TRACED, REUSED OR REPRODUCED IN ANY WAY, BY ANY MEANS, WITHOUT THE EXPRESSED WRITTEN PERMISSION OF WILLIAM PECK & ASSOCIATES, INC.. ALL RIGHTS RESERVED THIS DOCUMENT IS RELEASED FOR THE PURPOSE OF INTERMIN REVIEW UNDER THE AUTHORITY OF WILLIAM PECK & ASSOCIATES, ON THIS PLOT DATE AMD IS NOT TO BE USED BY AUTHORITIES HAVING JURSDICTION FOR THE PURPOSE OF ISSUING CONSTRUCTION PERMITS BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House REVISIONS DATE 05-23-08 Scale: Drawn: Job: Sheet Number: E-03 OF 27 Appendix D.7.7.2 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.3 Energy Modeling BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House February 25, 2009 Chris Miles GreenCraft Builders LLC 105 W. Main Street Lewisville, Texas 214-718-8424 Building America Performance Analysis of the Colleyville House Dear Mr. Miles, BSC has completed initial energy analysis for the 2009 Greencraft Colleyville house in Texas. The analysis shows that the plan has a source energy consumption reduction of 70.5% relative to the Building America Benchmark Protocol. The following is a detailed explanation of the analysis and results as well as a discussion on the various attributes of the plan. BSC will be performance testing the 2008 Colleyville house the second week in March 2009. Sincerely, Philip Kerrigan Jr., PE Daniel Bergey Building Science Corporation Building Science Corporation Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 1 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas 1. Building Plan and Specifications The building characteristics used in this analysis are listed below. Details of the analysis are included later in the report. Floor area (ft2) 4886 Surface Area (ft2) 12598 Volume (ft3) 76929 Glazing Ratio (%) 18.9% Specifications Building Enclosure Ceiling Walls Foundation Windows Infiltration R-30 spray foam at roof deck to create Conditioned attic Icynene® 2x6, 24" oc framing with 3/4" XPS with R-19 Spray foam Icynene® 51% Flyash concrete monolithic slab with Termimesh termite control Pella ® fiberglass LoE3 (U=0.28, SHGC=0.24) 2.5 sq in leakage area per 100 sf envelope Mechanical systems Heat Cooling DHW Ducts Leakage Dehumidification Ventilation Return Pathways WaterFurnace COP 5 GSHP WaterFurnace 4 ton downstairs, 2 ton upstairs 6 wells 25' apart 300 ft deep 30 gal LowBoy gets hot water from GSHP Rinnai R94LSi Instantaneous Hot Water EF=0.82 for auxillary DHW R-4.2 flex runouts in unvented attic or in floor joists none to outside (5% or less) GeneralAire Model 1300 whole house dehumidifier ERV Fantech SER Series AirCyclerTM FR-V Supply-only system integrated with AHU 33% Duty Cycle: 10 minutes on; 20 minutes off, 50 CFM average flow Jump ducts at bedrooms and laundry Other Loads Lighting Appliances 2. CFL lighting package all screw base Energy Star fridge, DW, clothes washer Energy Analysis Baseline Energy Efficiency Package: A whole house hourly energy consumption parametric simulation was completed comparing the incremental energy consumption reduction for various energy efficiency strategies compared to the Building America Benchmark Protocol created by the Department of Energy. The simulation was run using EnergyGauge USA USRCBB v2.8.01 software developed by the Florida Solar Energy Center (FSEC). Each parametric step shows an increment over source energy use (IOSEU) over the Building America Benchmark Protocol for the change to the model. This can be used to evaluate the relative effects of each performance upgrade made to the model. Due to rounding error, the sum of incremental improvements does not precisely match the total improvement for all measures. Each step is described below and the results are discussed. Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 2 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas Parametric Annual Loads Study million Btu/year (source energy) 700.0 600.0 500.0 400.0 300.0 200.0 100.0 0.0 Heating Cooling Hot Water Lighting Other 50% Reduction 1. Plan Changes: This step reflects the difference in window distribution between the Benchmark and the planned house. 2. 1+ Shading: This step accounts for the shading provided by roof overhangs. Taken together with the previous step, the savings is 3.7% of Benchmark energy usage. 3. 2 + Air Seal: This step brings the modeled house to Building America targets for air infiltration. The IOSEU for this step was 12.5%. 4. 3 + Ducts to interior: In this step, all ductwork was well sealed and brought to the interior, greatly reducing leakage to outside. The IOSEU for this step was 16.6%. 5. 4 + 2x6 OVE Framing: Advanced framing on 24” centers saves labor while reducing thermal bridging in the walls. 2x6 walls provide space for R-19 cavity insulation, resulting in an IOSEU of 3.2%. 6. 5 + Insulating Sheathing: ¾” of XPS sheathing was added to the exterior of all exposed walls, for an IOSEU of 1.0%. 7. 6 + R-30 attic insulation: The ceiling insulation was increased from R-25 to R-30. This upgrade results in an IOSEU of 1.2%. 8. 7 + U=0.28, SHGC=0.24 Windows: All windows were set to those to be installed, for an IOSEU of 8%. 9. 8 + 0.82 EF Instantaneous gas hot water: A gas hot water tank with an EF rating of 0.56 was replaced with a high efficiency instantaneous gas hot water system. This resulted in an IOSEU of 1.5% for this step. 10. 9 + HRV: A heat recovery ventilator was added to the central air system. The IOSEU for this step was 0.7%. Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 3 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas 11. 10 + GSHP: A ground source heat pump with a COP of 5.0 was modeled. The IOSEU for this step was 17.5%. 12. 11 + CFLs: All light fixtures in the modeled house were provided with compact fluorescent bulbs. The IOSEU was 5.3%. 13. 12 + ES Appliances: The dishwasher, clothes washer, and refrigerator were replaced with Energy Star rated models. The IOSEU for this step was 1.9% 14. 10+ 80% Compact fluorescent lighting: The lighting scheme was changed from a 14% CFL lighting package to an 80% CFL package for all hard wired lights. This resulted in a IOSEU of 4.2% for this step. Total Source Energy Savings Parametric Run ID Description of change 0 Benchmark 1 Windows as-designed (H/C/DHW/Lights/Appliances/Plug) Annual % over BA Incr. Over energy Item Bmrk Bmrk cost Savings $5,602 -3.2% -3.2% $5,777 ($175) HERS Score Heating Load Cooling Load kBtuh kBtuh 142 174.4 197.7 142 170.4 178.6 2 Porches and overhangs 3.7% 6.9% $5,399 $378 130 175.7 188.2 3 Air Seal (2.5 Leakage Ratio) 16.2% 12.5% $4,708 $691 114 130.2 147.2 83.9 4 Ducts 5% leakage and in cond. space 32.8% 16.6% $3,795 $913 92 96.8 5 R-19 OVE Walls 35.7% 3.0% $3,632 $163 89 90.7 80.1 6 3/4" XPS 36.8% 1.0% $3,575 $58 87 89.4 79.4 7 R-30 Roof 38.0% 1.2% $3,506 $69 85 88 78 8 Windows Low-e (U=0.28, SHGC=0.24) 46.0% 8.0% $3,064 $442 74 73.4 56.5 9 0.82 EF Inst. DHW 47.5% 1.5% $2,968 $96 70 73.4 56.5 10 HRV 48.1% 0.7% $2,931 $37 69 72.4 55.5 11 WaterFurnace GSHP COP=5 63.3% 17.5% $2,094 $965 53 72.4 55.5 12 CFL Lighting 68.6% 5.3% $1,802 $292 48 72.4 55.5 13 ES Appliances 70.5% 1.9% $1,680 $122 47 72.4 55.5 Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 4 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas 3. Energy Components The pie charts below reflect the component energy use for benchmark and the BA characteristics model. Because most of the savings were in heating and cooling, the plug loads, which are dependent on occupant behavior, and not on the building design, form a larger fraction of the total load. Benchmark Component Energy Use MEL, 75 Million Btu Lighting, 54 Million Btu DHW, 26 Million Btu Cooling, 286 Million Btu Heating, 192 Million Btu Cooling Heating DHW Lighting MEL Prototype Component Energy Use Cooling, 56 Million Btu Cooling Heating MEL, 71 Million Btu DHW Lighting MEL Heating, 29 Million Btu Lighting, 22 Million Btu DHW, 9 Million Btu Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 5 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas 4. End Use Site and Source Energy GreenCraft: Colleyville House ESTIMATED WHOLE HOUSE ENERGY USE Source (106 BTU/yr) Site (106 BTU/yr) Area + Bsmt (sq ft) 69 189 4886 +0 % Electric No. of Bedrooms 72% 4 Table 1. Summary of End-Use Site-Energy Annual Site Energy Manual Benchmark End-Use Prototype kWh therms kWh therms Space Heating 16656 0 2411 0 Space Cooling 24886 DHW 0 Lighting* 4717 Appliances + Plug 5695 OA Ventilation** 112 Total Usage 52064.75 Site Generation 0 Net Energy Use 52065 4782 236 0 114 5293 80 1946 114 178 350 14610 194 0 350 14610 194 *Lighting end-use includes both interior and exterior lighting **This OA Ventilation energy consumption is for fan energy only, space conditioning is included in Space Heating and Cooling Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 6 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Energy Analysis for Greencraft Colleyville House, Texas Table 2. Summary of End-Use Source-Energy and Savings Source Energy Savings Estimated Annual Source Energy % of End-Use % of Total Manual Benchmark Prototype Prototype Prototype 10^6 BTU/yr 10^6 BTU/yr savings savings Space Heating 191.2 27.7 86% 26% Space Cooling 285.7 54.9 81% 36% DHW 25.8 8.7 66% 3% Lighting* 54.2 22.3 59% 5% End-Use Appliances + Plug 77.8 73.2 6% 1% OA Ventilation** 1.3 2.0 -60% 0% Total Usage 636 189 70% 70% 70% 70% Site Generation 0 0 Net Energy Use 636 189 0% Notes: The "% of End-Use" columns show prototype energy savings in each end-use category. The "% of Total" columns show component savings contribution to the overall savings. Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.3 7 7 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.4 Manual J Calculations BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 1 Load Preview Report Scope Has AED Building System 1 Yes Area Sen Gain Lat Gain Net Gain Sen Loss Sys Htg CFM Sys Clg CFM Sys Act CFM 912 4,682 46,192 11,172 57,364 87,459 949 1,774 1,774 972 3,585 33,181 7,215 40,396 68,298 799 1,353 1,353 3,919 2,614 6,533 7,837 Net Ton Rec Ton ft.² /Ton 4.78 5.13 3.37 3.69 Ventilation Zone 1 Duct Size 18 3,585 29,262 4,601 33,863 60,461 799 1,353 1,353 18 1-Master Bath 208 2,233 342 2,575 6,359 84 103 103 1-6 2-Master Bedroom 252 1,972 576 2,548 3,490 46 91 91 1-6 3-Master Closet 150 783 130 913 2,445 32 36 36 1-4 4-Hidden Closet 36 290 49 339 912 12 13 13 1-4 5-Powder Bath 36 290 49 339 912 12 13 13 1-4 6-Living 525 4,781 685 5,466 7,290 96 221 221 2-6 7-Entry 144 1,133 147 1,280 2,924 39 52 52 1-4 8-Dining Room 285 3,416 503 3,919 6,633 88 158 158 1-8 9-Kitchen 320 1,445 0 1,445 245 3 67 67 1-5 10-Game Room 320 2,579 225 2,804 5,152 68 119 119 1-6 96 519 78 597 1,402 19 24 24 1-4 12-Utility 160 773 147 920 2,652 35 36 36 1-4 13-Office 160 1,093 228 1,321 4,026 53 51 51 1-4 11-Bar 14-East Pwdr Bath 48 192 49 241 823 11 9 9 1-4 15-Stairs / Hall 216 612 57 669 1,400 19 28 28 1-4 16-Media Room 448 2,949 840 3,789 8,118 107 136 136 1-7 17-Observation 100 2,845 261 3,106 3,273 43 132 132 1-7 81 1,357 235 1,592 2,405 32 63 63 1-5 1,097 13,012 3,956 16,968 19,160 150 421 421 10 3,919 2,614 6,533 7,837 18-Upper Master Bedroom System 2 Yes 1.41 1.45 759 Ventilation Zone 1 1,097 9,093 1,342 10,435 11,323 150 421 421 10 19-Bedroom 4 234 2,423 364 2,787 2,682 35 112 112 1-6 20-Bedroom 3 156 1,402 264 1,666 1,113 15 65 65 1-5 21-Bath 2 143 1,601 127 1,728 1,932 26 74 74 1-5 22-Bedroom 2 168 1,372 338 1,710 1,922 25 63 63 1-5 23-Kids Study 330 1,806 191 1,997 2,859 38 84 84 1-5 66 489 58 547 815 11 23 23 1-4 24-Upstairs Bath C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 2 Total Building Summary Loads Component Description 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 10D-w: Glazing-French door, double pane low-e glass (e = 0.10), wood frame, u-value 0.49, SHGC 0.32 11N: Door-Metal - Polystyrene Core 12C1-0bw: Wall-Frame, R-13.3 open cell 1/2 lb. spray foam insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 18B1-21o: Partition Roof/Ceiling (STD=15, WTD=15)Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam in 2 x 6 joist cavity 22A-ph: Floor-Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy moist soil open cell foam: Partition Floor (STD=15, WTD=15)-Over open crawl space or garage, Custom, over garage with open cell foam Area Quan 808.5 Sen Loss 13,346 Lat Gain 0 Sen Gain 14,354 Total Gain 14,354 84 2,059 0 1,583 1,583 63 4232.5 1,103 19,055 0 0 794 8,381 794 8,381 4314 3,301 0 3,301 3,301 303 20,573 0 0 0 701 536 0 536 536 59,973 0 2,000 0 0 11,811 15,675 0 3,943 5,229 28,949 2,300 1,200 0 0 5,906 7,837 28,949 4,300 1,200 0 0 9,849 13,066 87,459 11,172 46,192 57,364 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 219, Summer CFM: 219 Ventilation: Winter CFM: 290, Summer CFM: 290 10 0 Total Building Load Totals: Check Figures Total Building Supply CFM: Square ft. of Room Area: Volume (ft³) of Cond. Space: 1,774 4,682 52,455 Building Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: CFM Per Square ft.: Square ft. Per Ton: 87,459 46,192 11,172 57,364 Btuh Btuh Btuh Btuh 0.379 912 87.459 81 19 4.78 MBH % % Tons (Based On Sensible + Latent) 5.13 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 3 Total Building Summary Loads (cont'd) Notes All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 4 System 1 Summary Loads Component Description 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 10D-w: Glazing-French door, double pane low-e glass (e = 0.10), wood frame, u-value 0.49, SHGC 0.32 11N: Door-Metal - Polystyrene Core 12C1-0bw: Wall-Frame, R-13.3 open cell 1/2 lb. spray foam insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 18B1-21o: Partition Roof/Ceiling (STD=15, WTD=15)Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam in 2 x 6 joist cavity 22A-ph: Floor-Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy moist soil Area Quan 637.5 Sen Loss 10,524 Lat Gain 0 Sen Gain 10,590 Total Gain 10,590 84 2,059 0 1,583 1,583 63 3143.5 1,103 14,152 0 0 794 6,227 794 6,227 3217 2,463 0 2,463 2,463 303 20,573 0 0 0 50,874 0 1,400 0 0 9,587 7,837 0 3,201 2,614 21,657 1,610 1,200 0 0 4,795 3,919 21,657 3,010 1,200 0 0 7,996 6,533 68,298 7,215 33,181 40,396 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 177, Summer CFM: 177 Ventilation: Winter CFM: 145, Summer CFM: 145 7 0 System 1 Load Totals: Check Figures Supply CFM: Square ft. of Room Area: Volume (ft³) of Cond. Space: 1,353 3,585 42,582 System Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: CFM Per Square ft.: Square ft. Per Ton: 68,298 33,181 7,215 40,396 Btuh Btuh Btuh Btuh 0.378 972 68.298 82 18 3.37 MBH % % Tons (Based On Sensible + Latent) 3.69 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 5 System 2 Summary Loads Component Description 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 12C1-0bw: Wall-Frame, R-13.3 open cell 1/2 lb. spray foam insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 18B1-21o: Partition Roof/Ceiling (STD=15, WTD=15)Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam in 2 x 6 joist cavity open cell foam: Partition Floor (STD=15, WTD=15)-Over open crawl space or garage, Custom, over garage with open cell foam Area Quan 171 Sen Loss 2,822 Lat Gain 0 Sen Gain 3,764 Total Gain 3,764 1089 4,903 0 2,154 2,154 1097 838 0 838 838 701 536 0 536 536 9,099 0 600 0 0 2,224 7,837 0 742 2,614 7,292 690 0 0 0 1,111 3,919 7,292 1,290 0 0 0 1,853 6,533 19,160 3,956 13,012 16,968 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 41, Summer CFM: 41 Ventilation: Winter CFM: 145, Summer CFM: 145 3 0 System 2 Load Totals: Check Figures Supply CFM: Square ft. of Room Area: Volume (ft³) of Cond. Space: 421 1,097 9,873 System Loads Total Heating Required Including Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: CFM Per Square ft.: Square ft. Per Ton: 19,160 13,012 3,956 16,968 Btuh Btuh Btuh Btuh 0.383 759 19.160 77 23 1.41 MBH % % Tons (Based On Sensible + Latent) 1.45 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 6 System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 10D-w: Glazing-French door, double pane low-e glass (e = 0.10), wood frame, u-value 0.49, SHGC 0.32 11N: Door-Metal - Polystyrene Core 12C1-0bw: Wall-Frame, R-13.3 open cell 1/2 lb. spray foam insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 18B1-21o: Partition Roof/Ceiling (STD=15, WTD=15)Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam in 2 x 6 joist cavity 22A-ph: Floor-Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, heavy moist soil Area Quan 637.5 Sen Loss 10,524 Lat Gain 0 Sen Gain 10,590 Total Gain 10,590 84 2,059 0 1,583 1,583 63 3143.5 1,103 14,152 0 0 794 6,227 794 6,227 3217 2,463 0 2,463 2,463 303 20,573 0 0 0 50,874 0 1,400 0 0 9,587 0 3,201 21,657 1,610 1,200 0 0 4,795 21,657 3,010 1,200 0 0 7,996 60,461 4,601 29,262 33,863 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 177, Summer CFM: 177 7 0 System 1, Zone 1 Load Totals: Check Figures Supply CFM: Square ft. of Room Area: Volume (ft³) of Cond. Space: Zone Loads Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: 1,353 3,585 42,582 CFM Per Square ft.: Square ft. Per Ton: 60,461 29,262 4,601 33,863 Btuh Btuh Btuh Btuh 0.378 1,185 60.461 86 14 2.82 MBH % % Tons (Based On Sensible + Latent) 3.03 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 7 System 2, Zone 1 Summary Loads (Average Load Procedure for Rooms) Component Description 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 12C1-0bw: Wall-Frame, R-13.3 open cell 1/2 lb. spray foam insulation in 2 x 4 stud cavity, no board insulation, brick finish, wood studs 18B1-21o: Partition Roof/Ceiling (STD=15, WTD=15)Roof Joists Between Roof Deck and Ceiling or Foam Encapsulated Roof Joists, Spray Foam Insulation, White or Light Color Asphalt Shingle, Any Wood Shake, Dark or Medium Color Tile, Slate or Concrete, Light or Unpainted Metal, Light or Silver Membrane, Light Tar and Gravel, R-21 open cell 1/2 lb. spray foam in 2 x 6 joist cavity open cell foam: Partition Floor (STD=15, WTD=15)-Over open crawl space or garage, Custom, over garage with open cell foam Area Quan 171 Sen Loss 2,822 Lat Gain 0 Sen Gain 3,764 Total Gain 3,764 1089 4,903 0 2,154 2,154 1097 838 0 838 838 701 536 0 536 536 9,099 0 600 0 0 2,224 0 742 7,292 690 0 0 0 1,111 7,292 1,290 0 0 0 1,853 11,323 1,342 9,093 10,435 Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 41, Summer CFM: 41 3 0 System 2, Zone 1 Load Totals: Check Figures Supply CFM: Square ft. of Room Area: Volume (ft³) of Cond. Space: Zone Loads Total Heating Required: Total Sensible Gain: Total Latent Gain: Total Cooling Required: 421 1,097 9,873 CFM Per Square ft.: Square ft. Per Ton: 11,323 9,093 1,342 10,435 Btuh Btuh Btuh Btuh 0.383 1,246 11.323 87 13 0.87 MBH % % Tons (Based On Sensible + Latent) 0.88 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. C:\ ...\~UNTTL0.rhv Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 8 Detailed Room Loads - Room 1 - Master Bath (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 26.0 8.0 208.0 10.0 2,080.0 1 103 6 526 526 0.174 Item Description W -Wall-12C1-0bw 26 X 10 N -Wall-12C1-0bw 8 X 10 S -Wall-12C1-0bw 8 X 10 S -Gls-4A-6-o shgc-0.33 73%S (2) W -Gls-4A-6-o shgc-0.33 0%S N -Gls-4A-6-o shgc-0.33 100%S UP-Roof-Part-18B1-21o 26 X 8 Floor-22A-ph 42 ft..Per. Subtotals for Structure: Infil.: Win.: 19.0, Sum.: 19.0 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 103 3.0 0 15 15 11 11 19 19 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 250 64 70 10 -UValue 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 16.5 Sen Loss 1,125 288 315 166 Clg HTM 2.0 2.0 2.0 16.0 Lat Gain 0 0 0 0 Sen Gain 495 127 139 160 10 16 0.330 0.330 16.5 16.5 165 264 39.9 15.1 0 0 399 241 208 0.051 0.8 159 0.8 0 159 42 1.358 67.9 2,852 0.0 0 0 2.440 5,334 1,025 1.221 0 342 1,720 513 342 2,233 420 6,359 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 9 Detailed Room Loads - Room 2 - Master Bedroom (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 18.0 14.0 252.0 12.0 3,024.0 1 91 6 465 465 0.136 Item Description N -Wall-12C1-0bw 14 X 12 W -Wall-12C1-0bw 4 X 12 N -Gls-4A-6-o shgc-0.33 100%S (2) UP-Roof-Part-18B1-21o 18 X 14 Floor-22A-ph 18 ft..Per. Subtotals for Structure: Infil.: Win.: 9.8, Sum.: 9.8 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 91 1.8 0 8 9 10 11 10 10 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 120 48 48 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 540 216 792 Clg HTM 2.0 2.0 15.0 Lat Gain 0 0 0 Sen Gain 238 95 722 252 0.051 0.8 193 0.8 0 193 18 1.358 67.9 1,222 0.0 0 0 2.440 2,963 527 1.222 0 176 400 1,248 264 460 576 1,972 216 2 3,490 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 10 Detailed Room Loads - Room 3 - Master Closet (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 15.0 10.0 150.0 10.0 1,500.0 1 36 4 415 415 0.193 Item Description S -Wall-12C1-0bw 10 X 10 E -Wall-12C1-0bw 2 X 10 W -Wall-12C1-0bw 4 X 10 S -Gls-4A-6-o shgc-0.33 66%S UP-Roof-Part-18B1-21o 15 X 10 Floor-22A-ph 16 ft..Per. Subtotals for Structure: Infil.: Win.: 7.2, Sum.: 7.2 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: Area Quantity 89 20 40 11 150 -UValue 0.090 0.090 0.090 0.330 0.051 Htg HTM 4.5 4.5 4.5 16.5 0.8 16 1.358 160 1 1 1 36 1.4 0 6 16 4 11 7 7 CFM AC/hr CFM CFM % CFM % CFM CFM Sen Loss 401 90 180 182 115 Clg HTM 2.0 2.0 2.0 16.2 0.8 67.9 1,086 0.0 0 0 2.444 2,054 391 1.219 0 130 588 195 130 783 2,445 Lat Gain 0 0 0 0 0 Sen Gain 176 40 79 178 115 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 11 Detailed Room Loads - Room 4 - Hidden Closet (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 6.0 6.0 36.0 10.0 360.0 1 13 4 154 154 0.028 Item Description S -Wall-12C1-0bw 6 X 10 S -Gls-4A-6-o shgc-0.33 73%S UP-Roof-Part-18B1-21o 6 X 6 Floor-22A-ph 6 ft..Per. Subtotals for Structure: Infil.: Win.: 2.7, Sum.: 2.7 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Area Quantity 55 5 36 6 60 -UValue 0.090 0.330 0.051 1.358 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 13 2.2 0 2 16 1 11 3 3 CFM AC/hr CFM CFM % CFM % CFM CFM Htg HTM 4.5 16.5 0.8 67.9 Sen Loss 248 83 28 407 Clg HTM 2.0 16.0 0.8 0.0 Lat Gain 0 0 0 0 Sen Gain 109 80 28 0 2.433 766 146 1.217 0 49 217 73 49 290 912 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 12 Detailed Room Loads - Room 5 - Powder Bath (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 6.0 6.0 36.0 10.0 360.0 1 13 4 154 154 0.028 Item Description S -Wall-12C1-0bw 6 X 10 S -Gls-4A-6-o shgc-0.33 73%S UP-Roof-Part-18B1-21o 6 X 6 Floor-22A-ph 6 ft..Per. Subtotals for Structure: Infil.: Win.: 2.7, Sum.: 2.7 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Area Quantity 55 5 36 6 60 -UValue 0.090 0.330 0.051 1.358 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 13 2.2 0 2 16 1 11 3 3 CFM AC/hr CFM CFM % CFM % CFM CFM Htg HTM 4.5 16.5 0.8 67.9 Sen Loss 248 83 28 407 Clg HTM 2.0 16.0 0.8 0.0 Lat Gain 0 0 0 0 Sen Gain 109 80 28 0 2.433 766 146 1.217 0 49 217 73 49 290 912 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 13 Detailed Room Loads - Room 6 - Living (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 21.0 25.0 525.0 14.0 7,350.0 2 111 6 563 563 0.199 Item Description N -Wall-12C1-0bw 25 X 14 N -Gls-4A-6-o shgc-0.33 100%S (2) N -Gls-4A-6-o shgc-0.33 100%S N -Gls-10D-w shgc-0.32 100%S UP-Roof-Part-18B1-21o 21 X 25 Floor-22A-ph 25 ft..Per. Subtotals for Structure: Infil.: Win.: 15.8, Sum.: 15.8 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 221 1.8 0 17 8 24 11 16 16 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 148 84 -UValue 0.090 0.330 Htg HTM 4.5 16.5 Sen Loss 666 1,386 Clg HTM 2.0 15.0 Lat Gain 0 0 Sen Gain 293 1,264 76 0.330 16.5 1,254 15.1 0 1,144 42 0.490 24.5 1,029 18.8 0 791 525 0.051 0.8 402 0.8 0 402 25 1.358 67.9 1,698 0.0 0 0 2.443 6,435 855 1.220 0 285 400 3,894 427 460 685 4,781 350 2 7,290 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 14 Detailed Room Loads - Room 7 - Entry (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 16.0 9.0 144.0 12.0 1,728.0 1 52 4 601 601 0.399 Item Description S -Wall-12C1-0bw 9 X 12 W -Wall-12C1-0bw 6 X 12 S -Door-11N 6 X 7 UP-Roof-Part-18B1-21o 16 X 9 Floor-22A-ph 15 ft..Per. Subtotals for Structure: Infil.: Win.: 8.1, Sum.: 8.1 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: Area Quantity 66 72 42 144 -UValue 0.090 0.090 0.350 0.051 Htg HTM 4.5 4.5 17.5 0.8 15 1.358 180 1 1 1 52 1.8 0 7 13 6 11 8 8 CFM AC/hr CFM CFM % CFM % CFM CFM Sen Loss 297 324 735 110 Clg HTM 2.0 2.0 12.6 0.8 67.9 1,019 0.0 0 0 2.439 2,485 439 1.222 0 147 913 220 147 1,133 2,924 Lat Gain 0 0 0 0 Sen Gain 131 143 529 110 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 15 Detailed Room Loads - Room 8 - Dining Room (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 15.0 19.0 285.0 12.0 3,420.0 1 158 8 453 453 0.087 Item Description N -Wall-12C1-0bw 19 X 12 W -Wall-12C1-0bw 5 X 12 E -Wall-12C1-0bw 7 X 12 N -Gls-4A-6-o shgc-0.33 100%S (4) E -Gls-4A-6-o shgc-0.33 100%S E -Gls-10D-w shgc-0.32 100%S UP-Roof-Part-18B1-21o 15 X 19 Floor-22A-ph 31 ft..Per. Subtotals for Structure: Infil.: Win.: 16.8, Sum.: 16.8 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 158 2.8 0 16 10 17 11 17 17 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 137 60 45 91 -UValue 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 16.5 Sen Loss 617 270 203 1,500 Clg HTM 2.0 2.0 2.0 15.0 Lat Gain 0 0 0 0 Sen Gain 271 119 89 1,368 18 0.330 16.5 297 15.1 0 271 21 0.490 24.5 515 18.9 0 396 285 0.051 0.8 218 0.8 0 218 31 1.358 67.9 2,105 0.0 0 0 2.441 5,725 908 1.220 0 303 200 2,732 454 230 503 3,416 372 1 6,633 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 16 Detailed Room Loads - Room 9 - Kitchen (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 16.0 20.0 320.0 12.0 3,840.0 1 67 5 490 490 0.195 Item Description UP-Roof-Part-18B1-21o 16 X 20 Subtotals for Structure: Infil.: Win.: 0.0, Sum.: 0.0 Equipment: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Area Quantity 320 0 -UValue 0.051 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 67 1.0 0 1 1 7 11 0 0 CFM AC/hr CFM CFM % CFM % CFM CFM Htg HTM 0.8 Sen Loss 245 Clg HTM 0.8 Lat Gain 0 Sen Gain 245 0 245 0 0 0 0 0 245 0 1,200 0 1,445 245 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 17 Detailed Room Loads - Room 10 - Game Room (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 16.0 20.0 320.0 12.0 3,840.0 1 119 6 608 608 0.232 Item Description S -Wall-12C1-0bw 20 X 12 E -Wall-12C1-0bw 3 X 12 S -Gls-4A-6-o shgc-0.33 100%S (3) S -Gls-10D-w shgc-0.32 100%S UP-Roof-Part-18B1-21o 16 X 20 Floor-22A-ph 23 ft..Per. Subtotals for Structure: Infil.: Win.: 12.5, Sum.: 12.5 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 119 1.9 0 12 10 13 11 12 12 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 135 36 84 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 608 162 1,386 Clg HTM 2.0 2.0 15.0 Lat Gain 0 0 0 Sen Gain 267 71 1,263 21 0.490 24.5 515 18.9 0 396 320 0.051 0.8 245 0.8 0 245 23 1.358 67.9 1,562 0.0 0 0 2.442 4,478 674 1.221 0 225 2,242 337 225 2,579 276 5,152 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 18 Detailed Room Loads - Room 11 - Bar (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 12.0 8.0 96.0 12.0 1,152.0 1 24 4 275 275 0.086 Item Description S -Wall-12C1-0bw 8 X 12 S -Gls-4A-6-o shgc-0.33 73%S UP-Roof-Part-18B1-21o 12 X 8 Floor-22A-ph 8 ft..Per. Subtotals for Structure: Infil.: Win.: 4.3, Sum.: 4.3 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 24 1.3 0 3 14 3 11 4 4 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 86 10 96 -UValue 0.090 0.330 0.051 Htg HTM 4.5 16.5 0.8 Sen Loss 387 165 73 Clg HTM 2.0 15.9 0.8 Lat Gain 0 0 0 Sen Gain 170 159 73 8 1.358 67.9 543 0.0 0 0 2.438 1,168 234 1.219 0 78 402 117 78 519 96 1,402 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 19 Detailed Room Loads - Room 12 - Utility (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Item Description N -Wall-12C1-0bw 16 X 10 E -Wall-12C1-0bw 2 X 10 N -Gls-4A-6-o shgc-0.33 100%S Floor-22A-ph 18 ft..Per. Subtotals for Structure: Infil.: Win.: 8.1, Sum.: 8.1 Room Totals: C:\ ...\~UNTTL0.rhv Htg. & clg. 16.0 10.0 160.0 10.0 1,600.0 1 36 4 410 410 0.188 ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 36 1.3 0 6 18 4 11 8 8 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 145 20 15 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 653 90 248 Clg HTM 2.0 2.0 15.1 Lat Gain 0 0 0 Sen Gain 287 40 226 18 1.358 67.9 1,222 0.0 0 0 2.439 2,213 439 1.222 0 147 553 220 147 773 180 2,652 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 20 Detailed Room Loads - Room 13 - Office (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Item Description E -Wall-12C1-0bw 10 X 10 N -Wall-12C1-0bw 16 X 10 W -Wall-12C1-0bw 2 X 10 N -Gls-4A-6-o shgc-0.33 100%S Floor-22A-ph 28 ft..Per. Subtotals for Structure: Infil.: Win.: 12.6, Sum.: 12.6 Room Totals: C:\ ...\~UNTTL0.rhv Htg. & clg. 16.0 10.0 160.0 10.0 1,600.0 1 51 4 579 579 0.372 ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: Area Quantity 100 145 20 15 -UValue 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 16.5 28 1.358 280 1 1 1 51 1.9 0 10 19 5 11 13 13 CFM AC/hr CFM CFM % CFM % CFM CFM Sen Loss 450 653 90 248 Clg HTM 2.0 2.0 2.0 15.1 67.9 1,901 0.0 0 0 2.443 3,342 684 1.221 0 228 751 342 228 1,093 4,026 Lat Gain 0 0 0 0 Sen Gain 198 287 40 226 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 21 Detailed Room Loads - Room 14 - East Pwdr Bath (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 8.0 6.0 48.0 10.0 480.0 1 9 4 102 102 0.013 ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Item Description E -Wall-12C1-0bw 6 X 10 Floor-22A-ph 6 ft..Per. Area Quantity 60 6 Subtotals for Structure: Infil.: Win.: 2.7, Sum.: 2.7 60 Room Totals: C:\ ...\~UNTTL0.rhv -UValue 0.090 1.358 Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 9 1.1 0 2 22 1 11 3 3 CFM AC/hr CFM CFM % CFM % CFM CFM Htg HTM 4.5 67.9 Sen Loss 270 407 Clg HTM 2.0 0.0 Lat Gain 0 0 Sen Gain 119 0 2.433 677 146 1.217 0 49 119 73 49 192 823 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 22 Detailed Room Loads - Room 15 - Stairs / Hall (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 12.0 18.0 216.0 20.0 4,320.0 1 28 4 324 324 0.119 Item Description E -Wall-12C1-0bw 7 X 10 E -Door-11N 3 X 7 UP-Roof-Part-18B1-21o 12 X 18 Floor-22A-ph 7 ft..Per. Subtotals for Structure: Infil.: Win.: 3.2, Sum.: 3.2 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 28 0.4 0 3 12 3 11 3 3 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 49 21 216 -UValue 0.090 0.350 0.051 Htg HTM 4.5 17.5 0.8 Sen Loss 221 368 165 Clg HTM 2.0 12.6 0.8 Lat Gain 0 0 0 Sen Gain 97 265 165 7 1.358 67.9 475 0.0 0 0 2.443 1,229 171 1.214 0 57 527 85 57 612 70 1,400 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 23 Detailed Room Loads - Room 16 - Media Room (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 16.0 28.0 448.0 10.0 4,480.0 1 136 7 510 510 0.133 Item Description S -Wall-12C1-0bw 28 X 10 E -Wall-12C1-0bw 16 X 10 W -Wall-12C1-0bw 10 X 10 S -Gls-4A-6-o shgc-0.33 73%S (3) UP-Roof-Part-18B1-21o 16 X 28 Floor-22A-ph 54 ft..Per. Subtotals for Structure: Infil.: Win.: 24.4, Sum.: 24.4 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 136 1.8 0 19 14 15 11 24 24 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 250 160 100 30 -UValue 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 16.5 Sen Loss 1,125 720 450 495 Clg HTM 2.0 2.0 2.0 15.9 Lat Gain 0 0 0 0 Sen Gain 495 317 198 477 448 0.051 0.8 343 0.8 0 343 54 1.358 67.9 3,667 0.0 0 0 2.441 6,800 1,318 1.220 0 440 400 1,830 659 460 840 2,949 540 2 8,118 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 24 Detailed Room Loads - Room 17 - Observation (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 10.0 10.0 100.0 8.0 800.0 1 132 7 492 492 0.124 Item Description N -Wall-12C1-0bw 10 X 8 S -Wall-12C1-0bw 10 X 8 E -Wall-12C1-0bw 10 X 8 W -Wall-12C1-0bw 10 X 8 N -Gls-4A-6-o shgc-0.33 100%S (2) W -Gls-4A-6-o shgc-0.33 0%S (2) S -Gls-4A-6-o shgc-0.33 81%S (2) UP-Roof-Part-18B1-21o 10 X 10 Subtotals for Structure: Infil.: Win.: 14.5, Sum.: 14.5 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 132 9.9 0 8 6 14 11 14 14 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 53 53 80 53 27 -UValue 0.090 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 4.5 16.5 Sen Loss 239 239 360 239 446 Clg HTM 2.0 2.0 2.0 2.0 15.0 Lat Gain 0 0 0 0 0 Sen Gain 105 105 158 105 406 27 0.330 16.5 446 39.9 0 1,076 27 0.330 16.5 446 15.6 0 422 100 0.051 0.8 77 0.8 0 77 2.441 2,492 781 1.222 0 261 2,454 391 261 2,845 320 3,273 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 25 Detailed Room Loads - Room 18 - Upper Master Bedroom (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 9.0 9.0 81.0 8.0 648.0 1 63 5 460 460 0.173 Item Description N -Wall-12C1-0bw 9 X 8 E -Wall-12C1-0bw 9 X 8 W -Wall-12C1-0bw 9 X 8 S -Wall-12C1-0bw 9 X 8 N -Gls-4A-6-o shgc-0.33 100%S (2) S -Gls-4A-6-o shgc-0.33 100%S (2) UP-Roof-Part-18B1-21o 9 X 9 Subtotals for Structure: Infil.: Win.: 13.0, Sum.: 13.0 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 1 1 63 5.8 0 6 9 7 11 13 13 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 49.5 72 72 66 22.5 -UValue 0.090 0.090 0.090 0.090 0.330 Htg HTM 4.5 4.5 4.5 4.5 16.5 Sen Loss 223 324 324 297 372 Clg HTM 2.0 2.0 2.0 2.0 15.0 Lat Gain 0 0 0 0 0 Sen Gain 98 143 143 131 338 6 0.330 16.5 100 15.0 0 90 81 0.051 0.8 62 0.8 0 62 2.441 1,702 703 1.222 0 235 1,005 352 235 1,357 288 2,405 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 26 Detailed Room Loads - Room 19 - Bedroom 4 (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 13.0 18.0 234.0 9.0 2,106.0 1 112 6 571 571 0.205 Item Description S -Wall-12C1-0bw 18 X 9 E -Wall-12C1-0bw 13 X 9 S -Gls-4A-6-o shgc-0.33 66%S (2) E -Gls-4A-6-o shgc-0.33 0%S (2) UP-Roof-Part-18B1-21o 13 X 18 Floor-Part-open cell foam 18 X 13 Subtotals for Structure: Infil.: Win.: 9.1, Sum.: 9.1 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 112 3.2 0 34 31 39 34 9 9 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 129 102 33 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 581 459 544 Clg HTM 2.0 2.0 16.2 Lat Gain 0 0 0 Sen Gain 255 202 534 15 0.330 16.5 248 39.9 0 598 234 0.051 0.8 179 0.8 0 179 234 0.051 0.8 179 0.8 0 179 1.763 2,190 492 0.882 0 164 200 1,947 246 230 364 2,423 279 1 2,682 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 27 Detailed Room Loads - Room 20 - Bedroom 3 (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 12.0 13.0 156.0 9.0 1,404.0 1 65 5 476 476 0.184 Item Description E -Wall-12C1-0bw 12 X 9 E -Gls-4A-6-o shgc-0.33 0%S UP-Roof-Part-18B1-21o 12 X 13 Floor-Part-open cell foam 13 X 12 Subtotals for Structure: Infil.: Win.: 3.5, Sum.: 3.5 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 65 2.8 0 14 22 22 34 4 4 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 91.5 16.5 156 -UValue 0.090 0.330 0.051 Htg HTM 4.5 16.5 0.8 Sen Loss 412 272 119 Clg HTM 2.0 39.9 0.8 Lat Gain 0 0 0 Sen Gain 181 658 119 156 0.051 0.8 119 0.8 0 119 1.769 922 191 0.880 0 64 200 1,077 95 230 264 1,402 108 1 1,113 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 28 Detailed Room Loads - Room 21 - Bath 2 (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 11.0 13.0 143.0 9.0 1,287.0 1 74 5 543 543 0.239 Item Description N -Wall-12C1-0bw 13 X 9 E -Wall-12C1-0bw 11 X 9 E -Gls-4A-6-o shgc-0.33 0%S (2) N -Gls-4A-6-o shgc-0.33 100%S (2) UP-Roof-Part-18B1-21o 11 X 13 Floor-Part-open cell foam 13 X 11 Subtotals for Structure: Infil.: Win.: 7.1, Sum.: 7.1 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 74 3.5 0 25 33 26 34 7 7 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 102 84 15 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 459 378 248 Clg HTM 2.0 2.0 39.9 Lat Gain 0 0 0 Sen Gain 202 166 598 15 0.330 16.5 248 15.1 0 226 143 0.051 0.8 109 0.8 0 109 143 0.051 0.8 109 0.8 0 109 1.764 1,551 381 0.884 0 127 1,410 191 127 1,601 216 1,932 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 29 Detailed Room Loads - Room 22 - Bedroom 2 (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 14.0 12.0 168.0 9.0 1,512.0 1 63 5 465 465 0.176 Item Description N -Wall-12C1-0bw 12 X 9 W -Wall-12C1-0bw 14 X 9 N -Gls-4A-6-o shgc-0.33 100%S UP-Roof-Part-18B1-21o 14 X 12 Floor-Part-open cell foam 12 X 14 Subtotals for Structure: Infil.: Win.: 7.6, Sum.: 7.6 People: 200 lat/per, 230 sen/per: Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 63 2.5 0 25 39 22 34 8 8 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 91.5 126 16.5 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 412 567 272 Clg HTM 2.0 2.0 15.0 Lat Gain 0 0 0 Sen Gain 181 249 248 168 0.051 0.8 129 0.8 0 129 168 0.051 0.8 129 0.8 0 129 1.765 1,509 413 0.880 0 138 200 936 206 230 338 1,372 234 1 1,922 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 30 Detailed Room Loads - Room 23 - Kids Study (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Htg. & clg. 15.0 22.0 330.0 9.0 2,970.0 1 84 5 613 613 0.303 Item Description W -Wall-12C1-0bw 15 X 9 N -Wall-12C1-0bw 21 X 9 N -Gls-4A-6-o shgc-0.33 100%S (2) UP-Roof-Part-18B1-21o 15 X 22 Subtotals for Structure: Infil.: Win.: 10.6, Sum.: 10.6 Room Totals: C:\ ...\~UNTTL0.rhv ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 84 1.7 0 37 44 29 34 11 11 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 135 141 48 -UValue 0.090 0.090 0.330 Htg HTM 4.5 4.5 16.5 Sen Loss 608 635 792 Clg HTM 2.0 2.0 15.0 Lat Gain 0 0 0 Sen Gain 267 279 722 330 0.051 0.8 252 0.8 0 252 1.765 2,287 572 0.883 0 191 1,520 286 191 1,806 324 2,859 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 31 Detailed Room Loads - Room 24 - Upstairs Bath (Average Load Procedure) General Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Runout Duct Size: Runout Air Velocity: Runout Air Velocity: Actual Loss: Item Description S -Wall-12C1-0bw 11 X 9 S -Gls-4A-6-o shgc-0.33 100%S (2) UP-Roof-Part-18B1-21o 6 X 11 Subtotals for Structure: Infil.: Win.: 3.2, Sum.: 3.2 Room Totals: C:\ ...\~UNTTL0.rhv Htg. & clg. 6.0 11.0 66.0 9.0 594.0 1 23 4 259 259 0.077 ft. ft. sq.ft. ft. cu.ft. CFM in. ft./min. ft./min. in.wg./100 ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Required Vent.: Actual Winter Vent.: Percent of Supply.: Actual Summer Vent.: Percent of Supply: Actual Winter Infil.: Actual Summer Infil.: 1 2 1 23 2.3 0 10 46 8 34 3 3 CFM AC/hr CFM CFM % CFM % CFM CFM Area Quantity 87 12 -UValue 0.090 0.330 Htg HTM 4.5 16.5 Sen Loss 392 198 Clg HTM 2.0 15.0 Lat Gain 0 0 Sen Gain 172 180 66 0.051 0.8 50 0.8 0 50 1.768 640 175 0.879 0 58 402 87 58 489 99 815 Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 32 System 1 Room Load Summary Room No Name ---Zone 1--1 Master Bath 2 Master Bedroom 3 Master Closet 4 Hidden Closet 5 Powder Bath 6 Living 7 Entry 8 Dining Room 9 Kitchen 10 Game Room 11 Bar 12 Utility 13 Office 14 East Pwdr Bath 15 Stairs / Hall 16 Media Room 17 Observation 18 Upper Master Bedroom Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM 208 252 6,359 3,490 84 46 1-6 1-6 526 465 2,233 1,972 342 576 103 91 103 91 150 36 36 525 144 285 320 320 96 160 160 48 216 448 100 81 2,445 912 912 7,290 2,924 6,633 245 5,152 1,402 2,652 4,026 823 1,400 8,118 3,273 2,405 32 12 12 96 39 88 3 68 19 35 53 11 19 107 43 32 1-4 1-4 1-4 2-6 1-4 1-8 1-5 1-6 1-4 1-4 1-4 1-4 1-4 1-7 1-7 1-5 415 154 154 563 601 453 490 608 275 410 579 102 324 510 492 460 783 290 290 4,781 1,133 3,416 1,445 2,579 519 773 1,093 192 612 2,949 2,845 1,357 130 49 49 685 147 503 0 225 78 147 228 49 57 840 261 235 36 13 13 221 52 158 67 119 24 36 51 9 28 136 132 63 36 13 13 221 52 158 67 119 24 36 51 9 28 136 132 63 3,919 2,614 33,181 7,215 1,353 1,353 Ventilation System 1 total 7,837 3,585 68,298 System 1 Main Trunk Size: Velocity: Loss per 100 ft.: 799 18 in. 766 ft./min 0.083 in.wg Cooling System Summary Net Required: Recommended: Equipment Data Type: Model: Indoor Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: ARI Reference No.: C:\ ...\~UNTTL0.rhv Cooling Tons 3.37 3.69 Sensible/Latent Split 82% / 18% 75% / 25% Sensible Btuh 33,181 33,181 Latent Btuh 7,215 11,060 Total Btuh 40,396 44,241 Heating System Natural Gas Furnace Cooling System Standard Air Conditioner 0 AFUE 0 SEER 0 Btuh n/a n/a n/a 0 Btuh 0 Btuh 0 Btuh Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Rhvac - Residential & Light Commercial HVAC Loads Wolverton Co. Inc. Waxahachie, TX 75165 Elite Software Development, Inc. Colleyville Eco House (Arnett) Page 33 System 2 Room Load Summary Room No Name ---Zone 1--19 Bedroom 4 20 Bedroom 3 21 Bath 2 22 Bedroom 2 23 Kids Study 24 Upstairs Bath Area SF Htg Sens Btuh Min Htg CFM Run Duct Size Run Duct Vel Clg Sens Btuh Clg Lat Btuh Min Clg CFM Act Sys CFM 234 156 143 168 330 66 2,682 1,113 1,932 1,922 2,859 815 35 15 26 25 38 11 1-6 1-5 1-5 1-5 1-5 1-4 571 476 543 465 613 259 2,423 1,402 1,601 1,372 1,806 489 364 264 127 338 191 58 112 65 74 63 84 23 112 65 74 63 84 23 3,919 2,614 13,012 3,956 421 421 Ventilation System 2 total 7,837 1,097 19,160 System 2 Main Trunk Size: Velocity: Loss per 100 ft.: 150 10 in. 771 ft./min 0.185 in.wg Cooling System Summary Net Required: Recommended: Equipment Data Type: Model: Indoor Model: Brand: Efficiency: Sound: Capacity: Sensible Capacity: Latent Capacity: ARI Reference No.: C:\ ...\~UNTTL0.rhv Cooling Tons 1.41 1.45 Sensible/Latent Split 77% / 23% 75% / 25% Sensible Btuh 13,012 13,012 Latent Btuh 3,956 4,337 Total Btuh 16,968 17,349 Heating System Natural Gas Furnace Cooling System Standard Air Conditioner 0 AFUE 0 SEER 0 Btuh n/a n/a n/a 0 Btuh 0 Btuh 0 Btuh Thursday, June 25, 2009, 11:50 AM Appendix D.7.7.4 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.5 Field Testing BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House March 25, 2009 Chris Miles GreenCraft Builders LLC 105 W. Main Street Lewisville, Texas 214‐718‐8424 Building America Performance Testing of the Colleyville House Dear Mr. Miles, BSC visited the Colleyville house on March 10, 2009 and performed a full battery of performance tests for commissioning the house as a Building America building. Overall, the house tested very well and complies with Building America Specifications. Monitoring devices were also installed. Temperature and Relative Humidity HOBOs were installed in various areas of the house. It will be recording and saving data every half hour for a year. If you have any questions you can email me at [email protected]. The data will have to be downloaded in one year. Sincerely, Building Science Corporation Philip Kerrigan Jr., PE Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 1 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Building Plan and Specifications Building Science Corporation tested the Colleyville House (a 2007 Building America Research house) on March 10, 2009. This prototype reaches 69% vs. the Building America Benchmark without PVs and 76% with PV renewables. This prototype was given a full battery of tests, including multipoint blower door measurements; duct leakage (total and to the outside), and individual register flows. Overall, the Colleyville house tested extraordinarily well. In addition to meeting Building America performance criteria the house employs many conservative design elements (salvaged wood floors, recycled material countertop) and is certified LEED Platinum. Figure 1: Greencraft Colleyville House at 1708 Oak Knoll Drive, Colleyville, TX The building dimensions for the Colleyville house are listed below. Floor area Address 1708 Oak Knoll Drive Town, State Colleyville, TX 2 (ft ) 4886 Surface 2 (ft ) 12598 Volume 3 (ft ) 76929 Glazing Ratio (%) 18.9% The summary of our blower door data was as follows: CFM 50measured CFM 50goal Pass/Fail CFM @ 50 Pa 1097 CFM @ 50 Pa 3149 2.5 in2 Pass ACH 50 EqLA ELA Leak Ratio (cfm50/vol/hr) (in2@10 Pa) (in2@4 Pa) (EqLA/surf/100) 0.9 113.0 60.3 0.9 • Duct airtightness tests were run on the prototype; it met our requirement of 5% or less of nominal air handler flow duct leakage to outside (CFM 25), at 1.0% (30 CFM). Total duct leakage was on the order of 18% (430 CFM 50). • A GeneralAire model 1300 whole house dehumidifier was installed and configured correctly. • An Aprilaire Model 8126 Ventilation Control System was installed for outside air ventilation. • An Energy Star Compact Fluorescent Lighting package was installed as well as an Energy Star refrigerator, dishwasher and clothes washer. Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 2 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Construction Construction of the Colleyville House was well documented and they have a website solely dedicated to this project. http://www.colleyvilleecohouse.com/ GreenCraft Builders LLC. was the builder for this project, headed by Chris Miles. The house had guided tours throughout the construction process and over 4000 people were able to explore the project and get educated on the advanced technologies involved. Below are the characteristics of the house Specifications Building Enclosure Ceiling Walls Foundation Windows Infiltration R-30 spray foam at roof deck to create Conditioned attic Icynene® 2x6, 24" oc framing with 3/4" XPS with R-19 Spray foam Icynene® 51% Flyash concrete monolithic slab with Termimesh termite control Pella ® fiberglass LoE3 (U=0.28, SHGC=0.24) 2.5 sq in leakage area per 100 sf envelope Mechanical systems Heat Cooling DHW Ducts Leakage Dehumidification Ventilation Return Pathways WaterFurnace COP 5 GSHP WaterFurnace 4 ton downstairs, 2 ton upstairs 6 wells 25' apart 300 ft deep 30 gal LowBoy gets hot water from GSHP Rinnai R94LSi Instantaneous Hot Water EF=0.82 for auxillary DHW R-4.2 flex runouts in unvented attic or in floor joists none to outside (5% or less) GeneralAire Model 1300 whole house dehumidifier ERV Fantech SER Series AirCyclerTM FR-V Supply-only system integrated with AHU 33% Duty Cycle: 10 minutes on; 20 minutes off, 50 CFM average flow Jump ducts at bedrooms and laundry Other Loads Lighting Appliances Building Science Corporation 30 Forest Street, Somerville, MA 02143 CFL lighting package all screw base Energy Star fridge, DW, clothes washer P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 3 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Walls The house was cladded with Hardie Color Plus siding and stone over Tyvek® DrainWrap™ (with the corrugated grooves) over ¾” unskinned XPS sheathing over a wood framed wall with 2x6 24” OVE framing. The OVE framing includes a single top plate and two stud energy corners as well as windows framed at 2’ intervals. Figure 2: Walls wrapped with Tyvek® DrainWrap™ Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 4 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Roof The roof was constructed with an unvented cathedralized attic. Icynene® was sprayed to the underside of the roof sheathing to R‐30. A fully adhered roof membrane was installed over the roof sheathing, see photo below. Figure 3: Fully adhered roof membrane installed over roof sheathing as underlayment for standing seam metal roof Greencraft chose to construct an unvented cathedralized attic rather than the vented roof in a cathedralized attic installed at the 2007 Bannister house. This is due to cost concerns, mainly from a labor standpoint. Figure 4: Standing seam metal roof Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 5 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Foundation Termimesh was installed as a physical termite barrier before the concrete pour. Below are some photos. Termimesh protection around plumbing Termimesh installation Lattimore Concrete poured the concrete foundation for the Colleyville House. The concrete for the foundation of the house and porches consisted of 51% fly ash. This installation increases the strength of the concrete to 6000 psi (twice the normal strength). 51% fly ash concrete pour Other efficiency improvements include: Recycled glass material countertop Bamboo countertop Low VOC paint 3kW Photovoltaic installation Building Science Corporation 30 Forest Street, Somerville, MA 02143 Finished slab P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 6 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Mechanical Systems A 5.0 COP ground source heat pump from WaterFurnace with a variable speed air handler is installed for heating and cooling. The ductwork is assembled with flex with duct board. The duct work is located in conditioned space as the photos show below. Ductwork coming from mixing box Ductwork in cathedralized attic The ventilation system is a supply only central fan integrated supply (CFIS) system. 8” outside air duct with mechanical damper at return plenum Building Science Corporation 30 Forest Street, Somerville, MA 02143 Inline fan connecting three bathrooms and the laundry room to the outside via a single duct P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 7 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas The dehumidification system installed is a GeneralAire model 1300 whole house dehumidifier that draws directly from the main living space and dumps into the supply plenum of the HVAC system. This configuration allows for whole house dehumidification to run separate from heating and cooling because it is not fully coupled to the duct system (intake is from main living space). This prevents short circuiting as can happen when the dehumidifier is ducted to both supply and central return, which would require the air handle to run whenever there is a call for dehumidification. Figure 5: GeneralAire Model 1300 installed on top of air handler Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 8 9 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Field Testing Report for Greencraft Colleyville House, Texas Temperature and Relative Humidity Monitoring BSC installed a monitoring system in the Colleyville house to observe conditions for one year. Building Science Corporation requests monthly utility bills for comparison to our computer models. Purpose Questions to be answered are: 1. How do the temperatures and humidity levels compare in the various living areas and unvented attic? 2. Is interior relative humidity effectively controlled with the Aprilaire supplemental dehumidification system? Monitoring Instrumentation in Bedrooms and Attic BSC installed temperature/RH sensors called HOBO’s to keep track of temperatures and relative humidities; they are 1‐¾” x 2‐¼” x ¾”. A sample picture is shown here. Two types of HOBO’s will be installed: • Temperature/Relative Humidity loggers will be located in the bedrooms, near the thermostat, and upstairs. • An Onset Hobo Pro outdoor weather monitor, measuring temperature and relative humidity, will be installed under an exterior roof soffit. Building Science Corporation 30 Forest Street, Somerville, MA 02143 P: 978.589.5100 F: 978. 589.5103 www.buildingscience.com Appendix D.7.7.5 9 9 BA-0911: Prototype House Evaluations—Greencraft BUILDING LEAKAGE TESTBuilders Colleyville House Date of Test: 3/10/09 Test File: BD with Attic closed and Cupola Open Technician: P. Kerrigan Customer: Building Address: GreenCraft Builders P.O. 147 Lewisville, TX 75067 Phone 214-718-8424 1708 Oak Knoll Drive Colleyville, TX Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 1097 CFM ( +/- 1.4 %) 0.86 ACH 0.22 CFM per ft2 floor area 2. Leakage Areas: 127.4 in2 ( +/- 4.3 %) Canadian EqLA @ 10 Pa 72.4 in2 ( +/- 7.2 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.09 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 114.7 ( +/- 11.7 %) Exponent (n) = 0.577 ( +/- 0.032 ) Correlation Coefficient = 0.99218 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 144.5 CFM 0.11 ACH 28.9 CFM per person (using bedrooms + 1) 2. Estimated Design Infiltration Rate: Winter: 124.5 CFM 0.10 ACH Summer: 78.4 CFM 0.06 ACH 3. Recommended Whole Building Mechanical Ventilation Rate: (based on ASHRAE 62.2) 63.0 CFM Cost Estimates 1. Estimated Cost of Air Leakage for Heating: $ 0 per year heating 2. Estimated Cost of Air Leakage for Cooling: $ 0 per year cooling Appendix D.7.7.5 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House BUILDING LEAKAGE TEST Page 2 Date of Test: 3/10/09 Test File: BD with Attic closed and Cupola Open Building Conditions Inside Temperature: Outside Temperature: # of Stories 75 deg F 73 deg F 2.0 Heating Fuel: Heating Fuel Cost: HSPF: Heating Degree Days: Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: Heat Pump Wind Shield: # of Occupants M 4.0 # of Bedrooms: Volume: Surface Area: Floor Area: 4.0 76929 ft3 12598 ft2 4886 ft2 Ventilation Weather Factor: Energy Climate Factor: 0.89 18.0 Design Winter Wind Speed: Design Summer Wind Speed: 13.0 mph 7.0 mph Design Winter Temp Diff: Design Summer Temp Diff: 48 deg F 24 deg F 5.00 2407 16.0 1693 Comments Appendix D.7.7.5 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House BUILDING LEAKAGE TEST Page 3 Date of Test: 3/10/09 Test File: BD with Attic closed and Cupola Open Data Points: Nominal Building Fan Pressure Pressure (Pa) (Pa) 0.5 -48.5 -43.5 -38.8 -35.1 -29.6 -22.8 -19.6 0.6 n/a 38.0 33.4 26.8 242.6 200.4 144.7 117.2 n/a Nominal Flow Temperature Adjusted Flow % Error 1092 1025 920 923 838 711 639 1090 1023 918 922 837 709 638 0.4 0.3 -3.9 2.1 2.0 0.3 -1.8 Fan Configuration Baseline Std Dev (Pa) +/- 0.19 Ring A Ring A Ring A Ring B Ring B Ring B Ring B +/- 0.06 Appendix D.7.7.5 BA-0911: Prototype House Evaluations—Greencraft Building Leakage Curve Builders Colleyville House Date of Test: 3/10/09 Test File: BD with Attic closed and Cupola Open 2000 Building Leakage (cfm) 1000 900 800 700 600 500 400 300 200 4 5 6 7 8 9 10 20 Building Pressure (Pa) 30 40 50 Appendix D.7.7.5 60 BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House Appendix D.7.7.6 Builder’s Challenge Certificate RR-0911: BA-0911: Prototype House Evaluations—Greencraft Builders Colleyville House SM Estimated annual energy usage: Electric (kWh) 12607 Natural Gas (therms) 193 1708 Oak Knoll Dr, Colleyville, TX 76034 Rated by Building Science Corp. Rating conducted May 15th, 2009 Conditioned floor area (sq. ft.): 4886 www.buildingamerica.gov/challenge e h Meets T et. e mark ty in th nd safe ealth a rt, h , comfo uality nce, q rforma rgy pe ene e best izing th n Recog llenge rs Cha Builde Your Home! 36 08TX3600000001293 Appendix D.7.7.6 D-569