Trimline® Ventilation Products and Installation Instructions
Transcription
Trimline® Ventilation Products and Installation Instructions
® Trimline Ventilation Products and Installation Instructions Table of Contents Trimline® Ventilation Products Trimline® Rigid Roll® Plus ................................................................................. 2 Trimline® Rigid Vent Plus™ ................................................................................. 4 Trimline Multi Roll™ Vent ................................................................................ 6 Trimline® Soffit Strips ...................................................................................... 7 Trimline® EZ-PLUG™ ........................................................................................8 Trimline® Flow-Thru™ Furring Strips ...................................................................9 Trimline® Flow-Thru Battens™ for Tile Roofs ......................................................... 10 Trimline® Flow-Thru™ Cant Strips ...................................................................... 11 Trimline® VariaVent™ Ridge Vent, VariaBlock™ and VariaFlash™ .....................................12 Installation Instructions Ridge Vent ...................................................................................................14 Metal Roofs ..................................................................................................17 Hip Roofs ....................................................................................................18 Eave Intake or Ridge Exhaust ............................................................................20 Shed (Roof to Wall) Roofs ................................................................................21 Stone-Coated Steel Roofs .................................................................................22 Flat Tile Roofs ...............................................................................................23 Cedar Shake and Shingle Roofs ..........................................................................24 Trimline® EZ-PLUG™ ......................................................................................25 Ridge Vent Application in Seismic and Wind Designs ..............................................26 Determining Your Ventilation Needs ...................................................................27 Flow-Thru Battens .........................................................................................28 Flow-Thru Furring Strips .................................................................................28 Soffit Vent ....................................................................................................29 VariaVent™ Ridge Vent .....................................................................................30 VariaBlock™ ...................................................................................................31 Metric Conversion of Trimline® Ventilation Product Specs .........................................32 Trimline® Building Products Lifetime Manufacturer’s Warranty ...........34 Trimline® Ridge Vent Certification ...........................................................35 Trimline® Ridge Vent FAQs .......................................................................36 Trimline Rigid Roll Plus ® Products ® Performance Trimline Rigid Roll is the most tested and certified Ridge Vent on the market and provides superior ventilation, offering the most efficient way to achieve the industry-recommended balanced system. Trimline Ridge Vents provide continuous ventilation by exhausting hot, moist air from the attic while keeping out the most extreme weather elements like heavy rain, hail, sleet and snow. Trimline Rigid Roll Plus Benefits: • Efficiently vents at the hottest point of the roof, the ridge line. • Releases damaging hot, moist attic air using the circulation created by a balanced system. See “The Key to Proper Attic Ventilation” on page 5. • Made of HDPE Plastic, which withstands extreme temperatures and won’t crack, dent or damage from hail or ice. • Continues to prevent water infiltration in the event of a shingle blow-off. • Rigorously tested in extreme weather conditions to ensure no moisture infiltration. Passed 8.8” of rain per hour at 110-MPH winds with no infiltration. Passed snow simulation at 70 MPH with no infiltration. • Additionally Trimline Ridge Vents have been airflow tested in dusty environments according to ICC standards with no reduction in airflow. One-Pass™ Installation Trimline Rigid Roll offers One-Pass Installation, securing cap shingles and vent with the same nail. To assure the fastest installation process with a smooth and even ridge line, Trimline Rigid gid Roll Rol should not be pre-fastened along ong the entire vent prior to cap ap shingle installation. • Durable corrugated HDPE plastic enables the use of a coil nail gun with no crushing. • Trimline Rigid Roll Plus unrolls in seconds and can be easily trimmed to any length using a utility knife. See page 14 for installation instructions. MIAMI DADE COUNTY APPROVED 2 800-438-2920 www.trimline-products.com Diversi-Plast Products - Baldwyn, MS Miami-Dade County, Florida, Product Control Approved NOA No. 07-0124.09 Expiration Date: 10/31/12 ESR-2664 RIDGE VENTS - CLASS A or C AS TO AN EXTERNAL FIRE EXPOSURE ONLY WHEN INSTALLED IN ACCORDANCE WITH INSTRUCTIONS PROVIDED WITH RIDGE VENTS 8FA1 Trimline® Rigid Roll Plus® Patents: 5,934,995; 5,947,817; 6,450,882; 6,623,354; 6,913,530. Attractive Appearance With a low profile, Trimline Rigid Roll Plus provides effective ventilation while virtually disappearing into the roof line. Trimline Ridge Vents create the most attractive, straight and even roof line while providing superior ventilation. Trimline Rigid Roll Plus’s innovative design does not require baffles even in the harshest conditions. Trimline Rigid Roll Plus also eliminates the need for numerous unsightly vents protruding from the roof. Trimline Ridge Vents’ bafflefree design provide a clean ridge line appearance under pre-formed ridge caps such as Rapid Ridge and EZ Ridge. 4+/.+0'+&)' '065+056#..#66*' 4+&)'#0&10*+25T Products 4+/.+0''06 4+/.+0''06 168'065 6*'441..'&8'065 4+/.+0'+)+&1..2'%5 '0)6* FN1.. +&6*58#+.#$.' K[XM[#0&EEEfH[ I +&)''0622.+%#6+105 fL[j19k41(+.' '+)*6 '46+(+'&T TT 9+6*'%1//'0&'&41&7%6+&6*5 52*#.6*+0).' EFTK[ +6%*'5 GfEF61FNfEF #44#06; +('6+/'#07(#%674'4 #6'4+#. .#56+% #467/$'45 K[gvILKLJXM[gvILKLI EEEfH[gvILKLH Ef EE H[9+6*%1+.0#+.5gvGMMEH r K[XM[14EEEfH[ .#6+.' M[ '*#-' K[14M[ 610'g1#6'&6''. K[ 6#0&+0)'#/'6#. K[XM[14'6#. +211(5 EEEfH[ ''2#)'GF(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T 614/612 How Trimline Ridge Vent StormStop® Membrane Works The Trimline StormStop protects the attic from nature’s worst elements. In extreme weather conditions, damaging elements that could enter into the vent are blocked by the StormStop membrane in Rigid Roll Plus and Rigid Vent Plus. StormStop is a revolutionary spun-bound material that keeps moisture out while allowing continuous airflow. The StormStop material is 71% open and 29% closed, meaning that water will bead up on the material and roll back out of the vent. 800-438-2920 www.trimline-products.com 3 Trimline Rigid Vent Plus ® Products ™ 4’ and 8’ Sections 8#+.#$.'+0.19 #0&*+)*241(+.' Performance Trimline Rigid Vent Plus provides superior ventilation without the need for a baffle. Trimline vents efficiently exhaust damaging, hot air at the hottest point, the ridge line. The exclusive StormStop® membrane allows for effective ventilation while keeping nature’s most extreme elements from entering into the attic space. Additionally Trimline Ridge Vents have been airflow tested in dusty environments according to ICC standards with no reduction in airflow. Attractive Appearance With a low profile or high profile, Trimline Rigid Vent Plus provides effective ventilation while virtually disappearing into the roof line. Trimline Ridge Vents create the most attractive, straight and even roof line. Trimline’s innovative design does not require unattractive baffles, eliminating the need for numerous unsightly vents protruding from the ridge line. One-Pass™ Installation 5 /8” Low Profile Product virtually disappears into the roof line and can be used for most applications. Trimline Rigid Vent Plus offers One-Pass Installation, securing cap shingles and vent with the same nail. 5 • /8” Low Profile enables the use of a coil nail gun with no crushing or compressing. • 1” High Profile hand nail in one pass for quick installation with no crushing. 1” High Profile Product can be used when ridge space is limited, because it provides 19” NFA per lineal foot. The 1” profile also provides a unique shadow line highlighting the ridge line while maintaining a straight, clean, baffle-free ridge line when a distinctive high profile look is desired. • Trimline Rigid Vent Plus can be easily trimmed to any length using a utility knife. See page 14 for installation instructions. 4+/.+0''06 6*'4$#((.'&8'065 MIAMI DADE COUNTY APPROVED 4 800-438-2920 www.trimline-products.com Diversi-Plast Products - Baldwyn, MS Miami-Dade County, Florida, Product Control Approved NOA No. 07-0124.09 Expiration Date: 10/31/12 ESR-2664 RIDGE VENTS - CLASS A or C AS TO AN EXTERNAL FIRE EXPOSURE ONLY WHEN INSTALLED IN ACCORDANCE WITH INSTRUCTIONS PROVIDED WITH RIDGE VENTS 8FA1 Trimline® Rigid Vent Plus™ Patents: 6,450,882; 6,623,354; 6,913,530. Balanced System The Key to Proper Attic Ventilation 194+/.+0'+&)' '065X7.6+1.. '06#0&g 4+/.+0' 14g #2*+0).'5 614/612 4+/.+0' +&)''06 :*#756 .16%76(148'06+.#6+10 { 4+/.+0'7.6+ 1.. '06 +4(.19 66+% #4/+4+5'5 2#%' j*'4/#.(('%6k 057.#6+10 06#-'+4 #61((+6 :*#756 4#&+6+10#.'065 Providing a balanced system assures that damaging heat and moisture 11('%are being vented out of the attic, protecting the roof from premature deterioration, costly repairs and 06#-'+4 #61((+6 wasted utility dollars. If an attic has a properly balanced system, the airflow will move from the bottom of the attic to the top, pushing out heat and moisture in a natural flow using air pressure, thermal effect and diffusion. If the system were to be unbalanced, and the Net Free Area (NFA) at the ridge is higher than at the eave, a reverse airflow can occur causing an opposite effect to what is desired. The airflow will come from the top of the house and push down toward the eaves. As a result, heat and moisture are not allowed to escape and additional air and moisture can be drawn into the home. The FHA standard for static ventilation, as found in HUD requirements for proper ventilation, is recognized 16 2165 194#&+6+10#. '06+.#6+1014-5 #2*+0).'5 by builders throughout the 66+% 66 66+ 6 +% 66 +% industry. These +4(.19 2#%' #4/+4+5'5 requirements j*'4/#.(('%6k 057.#6+10 call for a ratio 06#-'+4 of 1:300. This #61((+6 means one square foot of ventilation for every 300 square feet of attic. Another ratio is 1:150, which actually provides more ventilation, 1 square foot for every 150 feet. In addition, specifications for good attic ventilation require a balanced system with at least 50% of the vents at the eave and 50% at the upper portion of the roof. (In cases where 50:50 balance cannot be achieved, always provide more than 50% of the ventilation at the eave). Check local code for proper amount of ventilation required. 16 2165 Products The most important factor in roof ventilation is the need for a balanced system. This means for every inch of air exhausted, it must be balanced by providing the same or greater amount of air intake at the eaves. 11('%- { When used with the correct combination of soffit vents, Trimline Ridge Vents offer an efficient means to achieve a balanced ventilation system. 4+/.+0'+)+&'062'%5 '0)6* H'%6+10jEF2'4%#4610k14 L 1.&g176'%6+105jJ2'4%#4610k K[XM[#0&EEEfH[ +&6*58#+.#$.' fL[j19k14E[j+)*k41(+.' '+)*6 I '46+(+'&T TT EFTK[j19k14EM[j+)*k GfEF61FNfEF +6%*'5 #44#06; +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'4g j19k41(+.' K[gvIMNLMXM[gvIMNME EEEfH[gvIMNMF Ef EE H[9+6*%1+.0#+.5gvGMMEI #467/$'45g j+)*k41(+.' +&)''0622.+%#6+105 9+6*'%1//'0&'&41&7%6+&6*5 52*#.6*+0).' K[XM[14EEEfH[ .#6+.' M[ '*#-' K[14M[ 610'g1#6'&6''. K[ 6#0&+0)'#/'6#. K[XM[14'6#. +211(5 EEEfH[ M[gH5'%6+10gvJFHNK EEEfH[gH5'%6+10gvJFHNJ EEEfH[gL5'%6+10gvJHNMG ''2#)'GF(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T 800-438-2920 www.trimline-products.com 5 Trimline Multi Roll Vent Products ™ Eave Intake, Off-Peak and Shed (Roof to Wall) The Solution to Exhaust and Intake Challenges Performance One-Pass™ Installation • Allows roofing contractors to install a balanced system - intake and exhaust on the roof. • Replaces fascia soffit vents in areas where fascia soffit vents are prohibited due to fire regulations. 4+/.+0'+&)''065 4+/.+0'7.6+1..'06 • Trimline’s exclusive StormStop® membrane which provides continuous ventilation while keeping out nature’s worst elements. • Tested in weather conditions to ensure no moisture infiltration. • Trimline Multi Roll Vent has been tested according to installation instructions and has no signs of water or ice back-up created from ice dams. 4+/.+0'7.6+1..'062'%5 '0)6* FN1.. +&6*8#+.#$.' L EfH[ '+)*6 '46+(+'&T TT fL[j19k41(+.' I JTGI[j19k41(+.' • Will not crush or compress when using a coil nail gun. See page 20-21 for installation instructions. Attractive Appearance • Designed with a low profile of only 5 /8”, which virtually disappears into the roof on eave, offpeak (firewall) and shed (roof to wall) applications. 4+/.+0'7.6+1.. '0622.+%#6+105 +6%*'5 GfEF61FNfEF #44#06; +('6+/'#07(#%674'4r ((g'#-j +4'9#..k #6'4+#. .#56+% *'&j11(61#..k #467/$'4 vJENKE ''2#)'GF(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T 6 • 20-foot roll unrolls in seconds, saving time over sectional products. 800-438-2920 www.trimline-products.com #8'06#-' +.'11(06#-' Trimline Multi Roll Vent Applications ((g2'#-#22.+%#6+10 (145*#4'&(+4'9#..514 .#4)'%'06'4$'#/5 Exhaust Attic Products Exhaust *'&j411(619#..k #22.+%#6+10(14 214%*411(5 Space p #8'+06#-' #22.+%#6+10 #.6'40#6+8'61 (#%5+#51((+68'065 IIntake In n Trimline® Rigid Roll Plus® Patents: 5,934,995; 5,947,817; 6,450,882; 6,623,354; 6,913,530. Another Option for Soffit Ventilation: Trimline® Soffit Strips 4+/.+0'1((+664+22'%5 Trimline Soffit Strips provide even, continuous air intake along the underside of eaves. Helping to achieve a balanced ventilation system by providing the required air intake at the eaves allows heat and moisture to be exhausted at the peak of the roof. See page 29 for f details. '0)6* H'%6+10jFH2'4%#4610k +&6*8#+.#$.' E[ '+)*6 EEfF[ '46+(+'&T TT JTGI[ #44#06; +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'4 vFNHJN ''2#)'GF(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T 800-438-2920 www.trimline-products.com 7 Trimline EZ-PLUG Products ® ™ 70 Convert from Traditional Vents (Pot Vents) to Trimline Ridge vents using EZ-PLUG. Looking for a way to upgrade the ventilation systems on a home? Help your homeowners have the best quality ventilation system. Upgrade to Trimline Ridge Vent and put your mind at ease about filling the holes with Trimline EZ-PLUG. EZ-PLUG has proven performance on over 100,000 homes. 168'065 4+/.+0'+&)''06 1(41/ 64#&+6+10#. 8'06561 4+/.+0' +&)' '065 EZ-PLUG Benefits Now converting from pot vents to ridge vent is quick and easy. Check out the easy step-by-step instructions in the installation section on page 25. can leave the roof knowing that your customers are protected from all weather elements. • Add money to your bottom line by upgrading your roofs with quality ridge ventilation. • Installs in seconds. • 12 times faster than plywood. • Can be nailed in extreme cold without cracking and will not fail or weaken in extreme heat. • Much stronger than a plywood patch cut rafter to rafter. • Used to repair rotten wood or other miscellaneous holes in the roof, provided the hole is no greater than 8” x 8”. • Makes it much safer for workers on the roof. No more dangerous large holes waiting for plywood to be cut and installed. EZ-PLUG fits most holes with very little or no cutting. • Prolong the roof life by exhausting hot, moist air at the hottest point of the roof, the ridge. Trimline also protects the roof from ice dams, wood rot and premature shingle wear. • Improved energy efficiency saves homeowners money on their energy bill. • An attractive, clean ridge line means no more unsightly traditional vents. 4+/ 4+/.+0'5 37+% 37+%+056#..#6+10 +056 • No callbacks from homeowners with your worry-free installation of EZ-PLUG and Trimline Ridge Vents. You 4+/.+0'g2'%5 EEKfL[:EEKfL[ 765+&'+/'05+105 11&'06'4 +/'05+105 *+%-0'55 #6'4+#. '+)*6+/+6 261JNN.$5T 1:1(FH#467/$'4 vMKNHJ KEfF[:KEfF[ fEJ[ K .#56+%#0& fEJ[5*'#6+0) K ''2#)'GG(14/'64+%/'#574'/'065T 8 4+/.+0'+&)''06 4+/ 800-438-2920 www.trimline-products.com g Trimline Flow-Thru Furring Strips ® TM -\ YYPUN:[YPWZ Performance +4(.19 Trimline Flow-Thru Furring Strips are the ideal replacement for wood furring strips and are 60% lighter weight than plywood. Moisture can come in the form of wind-driven .19g*47 744+0)64+25 rain from outside the home or moisture vapor from inside the home. In either case, this moisture can remain trapped between the exterior cladding/siding and the building paper/ house wrap. This unvented moisture can have a negative impact on the siding or cladding system as well as the building paper or house wrap. This trapped moisture can also lead to mold and mildew, causing potential health concerns and an unhealthy living environment. Unvented moisture can also severely reduce the service life of siding systems, paint or stain. +4(.19 +4(.19 Flow-Thru Furring Strips are a practical and easy venting solution that are made of a corrugated highdensity polyethylene. Flow-Thru Furring Strips provide both a vertical channel for air and moisture to vent and drain out as well as a horizontal channel to allow air movements; this minimizes the potential water and vapor penetration of the exterior wall. Trimline FlowThru Furring Strips are approved primarily for lowrise construction, for most exterior cladding systems, including wood, fiber-cement, vinyl siding and stucco, and EIFS systems. Quick and Easy Installation +4(.19n 1+5674' • Trimline Flow-Thru Furring Strips will save the homeowner money, both at the time of installation and in the long run. The long-term savings results from not having to pay for repainting or residing as often with FlowThru Furring Strips. • Air nailed without collapsing or compressing because of durable construction. • Compatible with most caulks and sealants. • Easily installed, requiring no special fasteners and no corrosion issues. • Won’t crack or split and easy to handle and store. • Every piece is dimensionally die cut so every piece is a consistent size and shape unlike wood battens. • The ventilation from Flow-Thru Furring Strips behind siding will extend the life of the fiber cement, cedar and stucco siding. • Cuts easily with a utility knife. • Bug screen not required. • Ideal for starter strip for siding applications. • House paint will last longer because the tannis can leach from the back of cedar siding if not back-primed and ruin the house wrap’s water repellency. See page 28 for installation instructions. .19g*47 744+0)64+25 '#574'/'065 4+/.+0' .19g*47 744+0)64+252'%5 '0)6* LTL 1.&g176'%6+105jFH2'4%#4610k +&6*8#+.#$.' EEfF[ EEfF[ GLTE// G fL[gFTL[#0&GfH[gITJ[ '46+(+'&T TT G #44#06; +('6+/'#07(#%674'4r #6'4+#. #467/$'45 .#56+% fL[gvJEENIXGfH[gvHNFHK G ''2#)'GG(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T LL[ FTJH/ Full view HH[ ETGF/ G HH[ ETGF/ Close-up fL[#0&GfH[ *+%-0'55 Products Ventilation system to help protect exterior cladding from the damaging affects of moisture. ™ fL[x G fH[ EN// fEM// Trimline® Flow-Thru™ Furring Strips Patents: 6,938,383; 7,117,649. 800-438-2920 www.trimline-products.com 9 Trimline Flow-Thru Battens for Tile Roofs ® Products ™ Performance Trimline’s Flow-Thru Battens’ unique design offers many features that provide long-term superior performance for tile roof applications. • Durable corrugated plastic allows water to drain under the tiles, eliminating build-up of moisture, snow and ice that can lead to leaks. It reduces premature re-roofing caused by water damage and poor air circulation. • Open-batten design provides ventilation by allowing air to move under the deck and the tiles. • Plastic design creates a gasket effect which eliminates leaking around fasteners. • Taller than traditional wood battens, Flow-Thru Battens keep the tile lug from making contact with the underlayment, reducing the chance for leaks. Quick and Easy Installation Flow-Thru Battens are engineered to make installation easy while minimizing tile breakage after installation. • Easily installed with a coil nail gun or staple gun and won’t crack or split. • Eliminates the need for lath and batten (counter batten) systems, offering a substantial savings in labor and a reduction in material used. • Unlike warped or knotty wood battens, each Flow-Thru Batten is consistent in quality, ensuring no waste in any bundle. • Every piece is dimensionally die cut so every piece is a consistent size. • Cuts easily with a utility knife for a perfect fit. See page 28 for installation instructions. Trimline® Tile Batten Patents: 6,357,193; RE 39,825. 10 800-438-2920 www.trimline-products.com 4+/.+0' .19g*47#66'02'%5 '0)6* L 1.&g176'%6+105jEF2'4%#4610k +&6*8#+.#$.' EEfF[ fH[j19k41(+.' '+)*6 G '46+(+'&T TT #44#06; Products +.'22.+%#6+10 ITJ[ +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'4 vJNMEK ''2#)'GF(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T .19g*47#66'0 22.+%#6+105 +.' .#6' +56+0%6+10+.'22.+%#6+10 Trimline® Flow-Thru™ Cant Strips TM * • Flow-Thru Cant Strips are the ideal replacement for wood cant strips and is used to elevate the starter course of slate or cedar shake to the same plane as the rest of the roof. HU[ :[HY[LY:[YPW Z • Trimline Cant Strips allow air and moisture to vent and drain out from the roof deck. • Flow-Thru Cant Strips are 60% lighter weight than wood, making it easy to handle, fasten with a coil nail gun and cut with a utility knife. 4+/.+0' .19g*47#0664+22'%5 '0)6* LTL 1.&g176'%6+105jFH2'4%#4610k fL[j19k41(+.' .19g*47#0664+2 22.+%#6+105 #44#06; +('6+/'#07(#%674'4r .#6' #6'4+#. .#56+% '*#-'5 EEfF[ +&6*8#+.#$.' '+)*6 #467/$'4 ''2#)'GG(14/'64+%/'#574'/'065T r''2#)'GH(14%1/2.'6'9#44#06;T G vJEENI 800-438-2920 www.trimline-products.com 11 TM Trimline VariaVent , VariaBlock and VariaFlash ® ™ Products ™ ™ VariaBlock TM Solutions for Tile Roofs VariaFlash Performance • Trimline VariaVent Ridge Vent combines ridge ventilation and variable weather blocking in one product. Each vent comes in a 4-foot sections with aluminum weather blocking already attached. • The variability of the weather blocking will allow the vent to fit any tile and metal on the market, while forming a weather-tight seal, meeting the Tile Roof Institute’s requirements for weather blocking and ventilation. • VariaVent allows venting at the hottest point, the ridge line. This eliminates attic hot spots, reducing cooling costs by removing hot moist air from the attic, prolonging the life of the roof. • Trimline VariaBlock variable closure solution for hip/ridge on tile and metal roofs is a durable and flexible weatherresistant product that can be used where weather blocking or mortar is required: head wall, hip, ridge and gable end. • Trimline VariaFlash universal flashing is the most expansive flashing available for flat or barrel tile roofs. VariaFlash will expand 40% in both directions, forming a weather-tight seal. TM Quick and Easy Installation lation VariaVent’s variable and efficient design of vent and weather blocking all in one allows for quick and easy installation on any style of tile or metal. The Varia Products offer a quicker alternative to mortar. See page 30 for installation instructions. VariaBlock’s 25-foot roll installs in minutes with no special tools required for installation. Simply roll out and press into the shape of the tile and remove the release liner so the buytl will adhere. See page 31 for installation instructions. VariaFlash’s 17-foot roll installs quickly using your hands. Two separate release liners are simply peeled off, and the flashing molds easily to conform to any roof surface. Attractive Appearance Unattractive traditional tile vents or messy mortar are no longer required. Varia products virtually disappear into the roof line and hips, creating the most attractive roof line. • As a durable and flexible weather-resistant product, VariaFlash can be used where weather blocking or mortar is required: head wall, chimney, hip, ridge, 4+/.+0'7.6+1..'06 gable end and pipe stack. (1406#-'10+.'11(5 If the tile roof has a need for on-the-roof intake Trimline Multi Roll Vent combined with Trimline Flow Thru Battens can be used for air intake. See page 20 for installation instructions. 12 800-438-2920 www.trimline-products.com 70 :*#756 06#-' 66+% 2#%' VariaBlock 70 1//102'%5(14 4+/.+0'#4+#'06X #4+#.1%-#0& #4+# .#5* +6%*'5 GfEF61EFfEF #44#06; +('6+/'#07(#%674'4r '#6*'4.1%-+0) g4'5+56#06;.#4g$#%-'& #6'4+#. #.7/+07/9+6*21.;'56'4g.#%37'4(+0+5* &*'5+8' +)*g6'/2'4#674'$76;.#&*'5+8' 9+6*5;06*'6+%4'.'#5'.+0'4g%#0 $'#22.+'&+0HN1 61EKJ1 Products r''2#)'GH(14%1/2.'6'9#44#06;T +467#..; 08+5+$.' 4+/.+0'#4+#'06+&)''062'%5 #4+#'06 '0)6* H'%6+10jEN2'4%#4610k +&6*8#+.#$.' K[ 8#+.#$.'1.145(14 '#6*'4.1%-+0) '#6*'4 #0+#.1%#0 fL[j19k41(+.' '+)*6 I '46+(+'&T TT EFTK[ '06#6'4+#. .#56+% #467/$'45 .#%-gvELNELX#0;10#46*gvELNELX '5'46'&gvELNEL X#0&gvELNEL ''2#)'GG(14/'64+%/'#574'/'065T .#%- #0;10#46* 4+/.+0'#4+#.1%-2'%5 '5'46'& '5'46 '& #0& #4+#.1%- '0)6* FI1.. +&6*8#+.#$.' EEGfH[ #0&EI[ #467/$'45g E E GfH[ .#%-gvELGNMX#0;10#46*gvELGEFX '5'46'&gvELGENX#0&gvELGEE #467/$'45g EI[ .#%-gvELGEGX'5'46'&gvELGEH ''2#)'GG(14/'64+%/'#574'/'065T 8#+.#$.' 1.145(14 #4+# .#5* 4+/.+0'#4+# .#5*2'%5 '0)6* EK1.. +&6*8#+.#$.' EEEfF[ #467/$'45 .#%-gvJFJGNX'5'46'&gvJFJGE *+/0';22.+%#6+105 .#%- ''2#)'GG(14/'64+%/'#574'/'065T +222.+%#6+105 Eliminates the need for large amounts of inventory, Varia products conform to any shape tile or metal. 800-438-2920 www.trimline-products.com '5'46'& 13 Ridge Vent 41&7%65 6175' Installation Instructions Ridge Preparation for Trimline® Ridge Vent Installation with Spanish and French Translation The amount of ventilation is controlled by the length of slot cut along the roof ridge. For the most attractive roof line, it is recommended that Trimline Ridge Vents are installed along the entire ridge of the roof. 1. Ridge Ventilation Slot Preparation Installation The slot may be pre-cut on a new roof before or after shingle installation or in a retrofit, the slot can be cut from the preshingled roof using a circular saw with a carbide tip blade. (Protective eye goggles should be worn during this process.) For Trimline low profile vents, cut a 2” slot (1” on each side of ridge) along the ridge(s). For a roof with a center beam, a 31⁄2” slot should be cut (13⁄4” on each side of ridge). For Trimline high profile vents, cut a 21⁄2” slot (11⁄4” on each side ridge). For center beam applications a 4” slot should be cut (2” on each side of ridge). A minimum of 6” must be left uncut on each end of the ridge. Once the slot is cut and any overlapping shingles covering the ridge are trimmed and removed, the ridge is ready for vent installation. 1. Preparación de la ranura para el respiradero de cumbrera La ranura puede cortarse previamente en un techo nuevo antes o después de la instalación de las tejas o en una remodelación, la ranura puede cortarse del techo al que se le ha instalado previamente las tejas usando una sierra circular con cuchilla de punta de carburo. (Se deben usar lentes protectores durante este proceso.) Para los respiraderos de bajo perfil de Trimline, corte una ranura de 2 pulg. (1 pulg. a cada lado de la cumbrera) a lo largo de la(s) cumbrera(s). Para un techo con una viga central, se debe cortar una ranura de 31⁄2 pulg. (13⁄4 pulg. a cada lado de la cumbrera). 14 800-438-2920 www.trimline-products.com Se debe dejar un mínimo de 6 pulg. sin cortar en cada extremo de la cumbrera. Una vez que se ha cortado la ranura y se han recortado y extraído las tejas superpuestas que cubren la cumbrera, ésta estará preparada para la instalación del respiradero. 1. Préparation de la fente de ventilation du faîtage La fente peut être précoupée sur un nouveau toit avant ou après l’installation du bardeau ou dans le cas d’une adapatation, la fente peut être coupée sur un toit préimbriqué au moyen d’une scie circulaire avec une lame à pointe au carbure. (Des lunettes protectrices doivent être portées durant ce processus.) Pour les évents à profil bas Trimline, coupez une fente de 5 cm (2,5 cm de chaque côté du faîtage) le long du(des) faîtage(s). Pour les toits avec une poutre centrale, une fente de 9 cm doit être coupée (4,5 cm de chaque côté du faîtage). Une distance minimale de 15 cm ne doit pas être coupée à chaque extrémité du faîtage. Une fois la fente coupée et tous les bardeaux se chevauchant couvrant le faîtage émargés et enlevés, l’évent est prêt à être installé sur le faîtage. 2. End Cap Installation Pull apart a pre-cut section of the foam end cap found with the vent. Using a utility knife, make a cut in the StormStop® material 1⁄2” on each side, back from the end of the section. Using construction adhesive or sealant caulk, coat both sides of the StormStop material where it has been cut back at the end of the vent. Insert the foam end cap with the cutback StormStop material between the foam end cap and the underside of the vent to assure a weather-tight seal. Because of the popularity of dimensional roofing material such as 40/50 year and lifetime laminated shingles, we require that a bead of sealant be applied to the roof shingles before installing the vent on the ridge. This sealant should fill any voids between the bottom of the vent and the surface of the shingle. Use either butyl sealant conforming to ASTM C1085, latex sealant conforming to ASTM C834, silicon sealant complying with ASTM C 920 or asphalt roofing cement complying with ASTM D4586. 2. Placement de l’évent sur le faîtage Déroulez ou placez l’évent Trimline sur toute la longueur de la fente tout en couvrant le minimum de 15 cm de faîtage non coupé aux deux extrémités. Lorsque vous utilisez les produits Rigid Roll, fixez au niveau de la bordure de départ en insérant le capuchon d’extrémité. Tirez l’évent fermement et fixez-le à une distance d’environ trois mètres. Tirez le reste de l’évent fermement et fixez en insérant le capuchon d’extrémité. Plusieurs longueurs d’évent peuvent être reliées en aboutant les sections fermement ensemble. Il n’est pas recommandé de clouer l’évent à tous les 15 cm avant d’installer le bardeau de capuchon du faîtage. Un capuchon d’extrémité doit être inséré à l’extrémité de chaque section (voir l’étape 3). À cause de la popularité des matériaux de couverture dimensionnels comme les bardeaux laminés avec garantie de 40/50 ans et à vie, nous exigeons qu’un cordon de produit d’obturation soit appliqué aux bardeaux de toit avant d’installer l’évent sur le faîtage. Ce produit d’obturation doit remplir tous les vides entre la partie inférieure de l’évent et la surface du bardeau. Utilisez soit un produit d’obturation en caoutchouc de butyle conforme à ASTM C1085, un produit d’obturation au latex conforme à ASTM C834, un produit d’obturation à base de silicone conforme à ASTM C920 ou un ciment de couverture bitumé conforme à ASTM D4586. 3. Vent Placement on Ridge Attach vent to the roof deck by driving a nail in each of the two corners on both ends of the vent. Also, drive two nails through the vent and foam end cap to hold foam in place on the ends of the ridge only. Nails should penetrate the wood roof deck at least 3⁄4”. It is not recommended to nail vent to ridge prior to cap shingle installation. Because of the popularity of dimensional roofing material such as the newer 40/50 year and lifetime laminated shingles, we require that a bead of sealant be applied to the roof shingles before installing the vent on the ridge. This sealant should fill any voids between the bottom of the vent and the surface of the shingle. Use either butyl sealant conforming to ASTM C1085, latex sealant conforming to ASTM C834, silicone sealant complying with ASTM C920 or asphalt roofing cement complying with ASTM 800-438-2920 www.trimline-products.com Installation 2. Ubicación del respiradero en la cumbrera Extienda o coloque el respiradero Trimline a lo largo de toda la longitud de la ranura cubriendo también las 6 pulg. sin cortar de la cumbrera en ambos extremos. Cuando use los productos Rigid Roll, asegúrelos en la arista de trabajo, colocando un tapón en el extremo. Extienda bien el respiradero y asegúrelo a aproximadamente 10 pies (3.04m). Extienda bien el resto del respiradero y asegúrelo colocando el tapón en el extremo. Se pueden unir longitudes múltiples del respiradero empalmando las secciones bien juntas y apretadas. No se recomienda clavar el respiradero cada 6 pulg. antes de la instalación de las tejas de remate de la cumbrera. Se debe colocar un tapón en el extremo de cada sección (Vea paso #3). Debido a la popularidad de los materiales dimensionales para techar como por ejemplo las nuevas tejas laminadas de 40/50 años de duración o que durarán toda la vida, requerimos que se aplique una gota de sellador a las tejas del techo antes de instalar el respiradero en la cumbrera. Este sellador debe llenar cualquier vacío entre la parte inferior del respiradero y la superficie de la teja. Use un sellador de butilo que cumpla con las especificaciones ASTM C1085, un sellador de látex que cumpla con las especificaciones ASTM C834, un sellador de silicona que cumpla con las especificaciones ASTM C920 o un cemento para techar de asfalto que cumpla con las especificaciones ASTM D4586. 15 D4586. Roll out or place Trimline vent along the entire length of slot also covering the 6” minimum uncut ridge on both ends. Bend vent into a “V” Shape. When using Rigid Roll products, secure at the lead edge after inserting the end cap. Nail should penetrate roof deck a minimum of 3⁄4”. Pull the vent tight and secure at about 10 feet. Pull the rest of the vent tight and secure, inserting the end cap. Multiple lengths of vent can be joined by butting the sections tightly together. End caps should be inserted at the beginning and end of each section. Do not pre-fasten ridge vent along the entire vent; with Trimline’s One-Pass Installation, it is not necessary to pre-fasten the vent every 2’ to 3’ prior to cap shingle installation. Installation 3. Instalación de los tapones ciegos Separe una sección del tapón ciego de espuma cortada previamente que viene con el respiradero. Con un cuchillo de uso general, haga un corte de 1⁄2 pulg en el material StormStop a cada lado, desde la parte trasera del extremo de la sección (Vea la ilustración #3). Con un adhesivo de construcción o sellador de juntas, cubra ambos lados del material StormStop donde se cortó, en la parte trasera del extremo del respiradero. Coloque el tapón ciego de espuma con el material StormStop recortado entre el tapón ciego de espuma y la parte inferior del respiradero para asegurar que quede correctamente sellado. Acople el respiradero a la plataforma del techo colocando un clavo en cada una de las dos esquinas en ambos extremos del respiradero. Instale también dos clavos a través del respiradero y del tapón ciego de espuma, para sujetar la espuma en su lugar, solamente en los extremos de la cumbrera. Los clavos deben introducirse al menos 1⁄2 pulg. en la plataforma del techo de madera. 16 3. Installation des capuchons d’extrémité Séparez une section précoupée du capuchon d’extrémité en mousse se trouvant dans l’évent. Au moyen d’un couteau universel, effectuez une coupe de 1,3 cm dans le matériau StormStop® de chaque côté, derrière l’extrémité de la section (voir l’illustration 3 en médaillon). Au moyen d’un adhésif de construction ou d’un calfeutrant à sceller, enduisez les deux côtés du matériau StormStop à l’endroit où il a été coupé à l’extrémité de l’évent. Insérez le capuchon d’extrémité en mousse avec le matériau StormStop coupé entre le 800-438-2920 www.trimline-products.com capuchon d’extrémité en mousse et la partie inférieure de l’évent pour assurer une étanchéité imperméable. Fixez l’évent au platelage en enfonçant un clou dans chacun des deux coins aux deux extrémités de l’évent. Enfoncez aussi deux clous à travers l’évent et le capuchon d’extrémité en mousse pour tenir la mousse en place sur les extrémités du faîtage seulement. Les clous doivent pénétrer le platelage en bois d’au moins 1,3 cm. 3B. Note: For “Class A” Installation Only For “Class A” Trimline® vent installation, follow steps 1, 2, 3 as stated above. Once the vent has been installed, use a utility knife with a hook blade and remove the corrugated plastic center section of the vent. Do this for the hip and ridge. This modified installation meets the requirements for UL790 “Class A,” standard installation meets the requirements for UL790 “Class A.” Follow remaining steps 4 as stated. 3B. Nota: Solamente para la instalación del “Clase A” Para la instalación del respiradero Trimline “Calse A”, siga los pasos 1, 2, 3 como se detallaron anteriormente. Una vez que el respiradero haya sido instalado, use un cuchillo de uso general con hoja de gancho para retirar la sección central de plástico corrugado del respirador (Vea la ilustración 3B). Haga esto para la Junta y la Cumbrera. Esta instalación modificada cumple con los requisitos para el “Clase A” UL790, la instalación estándar cumple con los requisitos para el “Clase C” UL790. Continuar con el paso número 4. 3B. Remarque: Pour les installations de « catégorie A » seulement Pour l’installation d’un évent Trimline de « catégorie A », suivez les étapes 1, 2, 3 indiquées ci-dessus. Une fois l’évent installé, utilisez un couteau universel avec une lame à crochet et retirez la section centrale en plastique ondulé de l’évent (voir l’illustration 3B). Cette installation modifiée est conforme aux exigences UL790 de « catégorie A », l’installation standard est conforme aux exigences UL790 de « catégorie C ». Continuez avec l’étape 4. 4. Cap Shingle Installation Using One-Pass™ Installation secure cap shingles and vent at the same time. Nail ridge caps with roofing nails in a common, overlapping pattern. Nails should penetrate the wood roof deck at least 3⁄4”. For the fastest installation, a coil nail gun can be used as long as the minimum penetration is 3⁄4”. It is important when installing this vent that you maintain the pitch of the roof. The vent has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded. 4. Instalación de las tejas de remate Con One-Pass Installation asegure las tejas de remate y el respiradero al mismo tiempo. Clave las cumbreras de remate con clavos para techos en un modelo típico de superposición. Los clavos deben introducirse al menos 1 ⁄2opulg. en la plataforma del techo de madera. Para conseguir una instalación más rápida, se puede usar una pistola de clavos siempre y cuando la introducción mínima sea de 1⁄2 pulg. Cuando se instala el respiradero es muy importante mantener la pendiente del techo. El respiradero se ha instalado correctamente si la parte inferior de éste está plana en el techo y el pico está ligeramente redondeado. 4. Installation des bardeaux de capuchon Au moyen de l’installation One-Pass, fixez les bardeaux de capuchon et l’évent en même temps. Clouez les capuchons du faîtage avec des clous de toiture dans un motif de recouvrement commun. Les clous doivent pénétrer le platelage en bois d’au moins 1,3 cm. Pour l’installation la plus rapide, vous pouvez utiliser un pistolet goujonneur à spire tant que la pénétration minimale est de 1,3 cm. Il est important lors de l’installation de cet évent de maintenir la pente du toit. L’évent est correctement installé si sa partie inférieure repose à plat sur le toit et que le sommet est légèrement arrondi. Metal Roofs Installation Instructions 41&7%65 6175' Leave opening at ridge. Place foam closure or metal closure on each side of ridge. Peel placement tape liner. Install Trimline Ridge Vent. Install metal ridge cap over Trimline Ridge Vent according to metal manufacturer’s installation instructions. 800-438-2920 www.trimline-products.com Installation 4+/.+0'+&)''06.75%#0 $'75'&(146*+5#22.+%#6+10T 17 Hip Roofs 41&7%65 6175' Installation Instructions 1. Hip and Ridge Ventilation Slot Preparation Installation Jt Determine how long of a hip and ridge ventilation slot will be required according to 1/300 rule. The ridge and hip ventilation slot may be pre-cut on a new roof before or after shingle installation or in a retrofit, the slot can be cut from the pre-shingled roof using a circular saw with a carbide tip blade. (Protective eye goggles should ELt be worn during EFt this process.) EL[ Start ridge ventilation slot 6” from point where hip and ridge meet. For Trimline® low profile vents, cut a 2” slot (1” on each side of ridge) along the ridge(s). For a roof with a center beam, a 31⁄2” slot should be cut (13⁄4” on each side of ridge). For Trimline high profile vents, cut a 21⁄2” slot (11⁄4” on each side of ridge). For center beam applications a 4” slot should be cut (2” on each side of ridge). If entire ridge requires ventilation, stop ventilation slot 6” from point where hip and ridge meet. To maintain structural integrity, one continuous slot is not recommended on hip applications. Start ventilation preparation by leaving 6” of hip uncut from where the ridge and hip meet. Cut a 31⁄2” wide slot for ventilation. Hip slot should be 18” in length, spaced with a 12” uncut area between each 18” opening. The slot for ventilation should not be cut any lower than the top 1⁄3 of the roof to maintain a balanced ventilation system. 2. End Cap Installation Pull apart a pre-cut section of the foam end cap found with the vent. Using a utility knife, make a cut in the StormStop® material 1⁄2” on each side, back from the end of the section. Using construction adhesive or sealant caulk, coat both sides of the StormStop material where it has been cut back at the end of the vent. Insert the foam end cap with the cut-back StormStop material 18 800-438-2920 www.trimline-products.com between the foam end cap and the underside of the vent to assure a weather-tight seal. Because of the popularity of dimensional roofing material such as 40/50 year and lifetime laminated shingles, we require that a bead of sealant be applied to the roof shingles before installing the vent on the ridge. This sealant should fill any voids between the bottom of the vent and the surface of the shingle. Use either butyl sealant conforming to ASTM C1085, latex sealant conforming to ASTM C834, silicon sealant complying with ASTM C 920 or asphalt roofing cement complying with ASTM D4586. 3. Vent Placement on Ridge Attach vent to the roof deck by driving a nail in each of the two corners on both ends of the vent. Also, drive two nails through the vent and foam end cap to hold foam in place on the ends of the ridge only. Nails should penetrate the wood roof deck at least 3⁄4”. It is not recommended to nail vent to ridge prior to cap shingle installation. Because of the popularity of dimensional roofing material such as the newer 40/50 year and lifetime laminated shingles we require that a bead of sealant be applied to the roof shingles, before installing the vent on the ridge. This sealant should fill any voids between the bottom of the vent and the surface of the shingle. Use either butyl sealant conforming to ASTM C1085, latex sealant conforming to ASTM C834, silicone sealant complying with ASTM C920 or asphalt roofing cement complying with ASTM D4586. Roll out or place Trimline vent along the entire length of slot also covering the 6” minimum uncut ridge on both ends. When using Rigid Roll products, secure at the lead edge after inserting the end cap. Shape vent in V Shape. Pull the vent tight and secure at about 10 feet. Pull the rest of the vent tight and secure, inserting the end cap. Multiple lengths of vent can be joined by butting the sections tightly together. End cap should be inserted at the beginning and end of each section. 4. Vent Placement on Hip Install a minimum of 2 cap shingles at the bottom of the hip. If the vent is not being run the entire length of the hip, the vent should overlap a minimum of 2 cap shingles at the end of the vent. Before installing the vent on the hip, lay a bead of sealant on each side of the pre-cut slots. This will create a seal on the step created by '#.#06 14#7.- length of the hip, use the cap shingles to create a transition. Use sealant to fill any void left between the shingles and the remaining top layer of the vent. Be sure to apply roofing sealant to any spaces left by cap shingle used for transition. If 2 or more sections of Trimline vent are being joined together, an end cap MUST be installed into each end of the joining sections. Repeat on all hips. 6. Cap Shingle Installation Apply the cap shingles to the hip and then to the ridge. Nail hip and ridge caps with roofing nails in a common overlapping pattern. Nails should penetrate the wood roof deck at least 3⁄4”. For fastest installation, a coil nail gun can be used as long as the minimum 3⁄4” penetration into the deck is maintained. It is important when installing this vent that you maintain the pitch of the roof. The vent has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded. overlapping pattern ttern of the shingles. The bead of sealant should be applied i d approximately ppr im t l 1” from fr m the edge of the precut slot. Note: For “Class A” Installation Only Installation For “Class A” Trimline vent installation, follow steps 1, 2, 3 as stated above. Once the vent has been installed, use a utility knife with a hook blade and remove the corrugated plastic center section of the vent. Do this for the hip and ridge. This modified installation meets the requirements for UL790 “Class A”; standard installation meets the requirements for UL790 “Class C.” Follow remaining steps 4, 5, 6 as stated. 5. Hip and Ridge Vent Transition Using a utility knife, trim the end of Trimline Ridge Vent from the hip to the ridge. This creates the most attractive ridge and hip line. Insert the foam end cap under the Trimline Ridge Vent where it is at full width. Fasten vent for hip at point where it meets ridge. Roll out or place the vent all of the way down the hip, covering 2 pre-laid cap shingles at the bottom of the hip. Go back over hip vents and fasten at 4” intervals. If the Trimline vent is not being run the entire 800-438-2920 www.trimline-products.com 19 Eave Intake or Off-Peak Exhaust Installation Instructions 41&7%6 6175' 1. Slot Preparation Determine amount of ventilation required and length of slot. Cut a horizontal 3⁄4” slot in the deck, leaving a minimum of 6” uncut on each end of the slot. Install underlayment and shingles per manufacturer’s instructions. Do not cover pre-cut slot. 2. End Cap Installation Cut end cap in a diagonal lengthwise. Cut a slit in the StormStop membrane 1⁄2” by the thick part of vent.Place sealant on both sides of membrane. Insert end cap with membrane touching the plastic part of vent. An end cap must be placed at the beginning and end of each vent section. 3. Trimline Multi Roll Vent Installation Lay a bead of sealant 3” below the cut slot. Place front edge of vent 4” below the pre-cut slot. Unfold the membrane and pull straight. Place a bead of sealant 41⁄2” above slot underneath membrane. Nail membrane and plastic to roof deck. All nails must penetrate the roof deck at least 3⁄4”. Nail down the bottom lead edge of vent and in the middle through the end cap. Roll out vent and pull tight; nail at 10 feet and again at the end of the roll. 4. Finishing Shingle Installation Installation Install felt and shingles on top of vent, treating the thick edge of the vent as a starter course. Install shingles per manufacturer’s instructions. Eave Intake for Tile Roof Application Follow Eave Intake steps 1-3 as noted aboved, then proceed to step 4 below for Tile application. 4. Install Trimline Flow-Thru Battens on up to three courses leading up to Trimline Multi Roll Vent. Metal flashing should be installed on top of the Trimline Multi Roll Vent. Use mastics at top edge and sides of Trimline Multi Roll Vent. Then install peel and seal underlayment starting at the 3” air intake and run all the way back to '6#. .#5*+0) next course of battens. On top of peel and seal underlayment, install at least 30# felt underlayment. Install next course of battens on top of felt. Finish by installing field tile on batten courses covering Trimline Multi Roll Vent and Flow-Thru Battens. Batten 30 lb. Felt Peel and Seal Mastics Caulk End cap Trim to fit Flashing Caulk Caulk Trimline l Vent Multi Rol n ru Batte Flow-Th 20 800-438-2920 www.trimline-products.com Shed (Roof to Wall) Roofs Installation Instructions 41&7%6 6175' 3. Sealant Placement 1. Slot Preparation Determine amount of ventilation required and length of slot. Cut a horizontal 1” slot in the deck right before the wall. Leave 6” uncut on each end of the slot. Install underlayment and shingles per manufacturer’s instructions. Do not cover pre-cut slot. 2. End Cap Installation 4. Trimline Multi Roll Vent Installation Nail lead edge of vent into roof deck. Nail foam end cap in place. All nails must penetrate the roof deck at least ¾”. Roll out #4 Trimline .#5*+0) #2'4 Multi Roll Vent and pull tight, nail at 10 feet and again at the end of the 4+/ roll. Tack the vent along the wall, making sure nails penetrate plastic and StormStop membrane. Nail every 6”. 5. Finishing Install metal flashing as counter flashing on top of Trimline Multi Roll Vent. Install siding over the vent piece on wall. When finished, siding should cover the wall and overlap the metal flashing. +.&.#0&4$#006'4(#%' 1/2.+#06 4+/.+0'7.6+ 1..'06 '065(14411(8'06+.#6+10 #4'1(6'0(170&+06*'51((+6T .#%+0)8'065+06*'5' .1%#6+105%4'#6'5#2'4('%6 .1% 2#6*(14(+4'61'06'46*'411( 2# 5647%674'T(6*'8'06/756$' 564 +06*+5.1%#6+10+6+5$'66'461 +0 2.#%'+6(#46*'4(41/6*'9#.. 2.# #0&%.15'4616*'(#5%+#T*' #0 8'06%#0#.51$'2.#%'&+06*' 88' (#5%+#140'#46*'.19'4'&)' ((#5 1(6*'411(T 800-438-2920 www.trimline-products.com Installation Trim end cap to fit at each end of vent. Cut a slit in the StormStop membrane 1⁄2” by the thick part of vent. Place sealant on both sides of StormStop membrane. Insert foam end cap with the cut#7.back StormStop material between the end cap and the underside of the vent. End caps must be installed at the beginning and end of each vent section. Lay a bead of sealant 31⁄2” below the cut slot. Place front edge of vent 41⁄2” below the pre-cut slot. Unfold the StormStop membrane and pull straight. Place a bead of sealant 41⁄2” above slot underneath StormStop membrane. 21 Stone-Coated Steel Roofs 41&7%65 6175' Installation Instructions 3. Vent Placement on Ridge 1. Ridge Ventilation Slot Preparation Cut the slot prior to installing the last course of shingle panels along the ridge in a re-roof or new construction application (protective eye goggles should be worn during this process). For Trimline® Plus low profile 7” vents, cut a 2” slot (1” on each side of ridge) along the ridge. A minimum of 6” must be left uncut on each end of the ridge. Once the slot is cut then measure and cut shingle panels to fit along the ridge; panels should not obstruct the slot. Once the panels are installed, the ridge is ready for vent installation. Retrofit with Stone-Coated Steel Installation If stone-coated steel is already installed, the slot can be cut from the pre-paneled roof using a circular saw with a combination blade (reversed) or a Tenryu Steel Pro blade (protective eye goggles should be worn during this process). For Trimline Plus low profile 7” vents, cut a 2” slot (1” on each side of ridge) along the ridge. A minimum of 6” must be left uncut on each end of the ridge. 22 2. End Cap Installation Pull apart a precut section of the foam end cap found with the vent, usually found in the first 3 feet of the roll. Use a utility knife to make a cut in the StormStop material 1⁄2” on each side, back from the end of the section (See insets). Using construction adhesive or sealant caulk, coat both sides of the StormStop material where it has been cut back at the end of the vent. Insert the foam end cap with the cut-back StormStop material between the foam end cap and the underside of the vent to assure a weather-tight seal. 800-438-2920 www.trimline-products.com Before installing the vent on the ridge a bead of sealant is required between the stone-coated steel and the underside of the ridge vent. This sealant should fill any voids between the bottom of the vent and the surface of the panel. Caulking and sealants shall be suitable for exterior use and be resistant to weathering; use either butyl or polyurethane sealants. The caulking and the sealants shall be compatible with and adhere to the materials to which they are applied. Check sealant manufacturer’s instructions and stone coated steel’s installation guide for compatibility. Roll out or o place Trimline vent along the entire en length of slot also covering the th 6” minimum uncut ridge on '#.#06 both ends. When using Rigid b 14#7.Roll R products, secure at the lead edge, ed inserting the end cap. Pull the th vent tight and secure at about 10 feet. Pull the rest of the vent tight and secure, inserting the end cap. Multiple lengths of vent can be joined by butting the sections tightly together. Trimline Plus with StormStop should have an end cap inserted at the end of each section. Attach vent to the roof deck by driving a nail or a #8 screw in each of the two corners on both ends of the vent. Also, drive two nails or #8 screws through the vent and foam end cap to hold foam in place on the ends of the ridge only. Fasteners should penetrate the wood roof deck at least 3⁄4”. It is recommended to fasten the vent to ridge prior to stonecoated steel hip/ridge cap installation. Vent should be secured every 5”. 4. Cap Shingle Installation It is important when installing this vent that you maintain the pitch of the roof. The vent has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded. Install hip/ridge caps per manufacturer’s installation guide. Each hip/ridge piece should clip together by inserting the return (at the nose of each piece) into the back clip which is located at the top of the hip/ridge cap section. Fasten cap to vent through the back clip using #8 screws. Fasteners should penetrate through the wood roof deck at least 3⁄4”. 41&7%65 6175' Flat Tile Roofs Installation Instructions 1. Ridge Ventilation Slot Preparation The slot must be cut on a new roof before field tile installation. The amount of ventilation is controlled by the length of slot cut along the roof ridge. Remember, for the most attractive roof line, it is recommended that Trimline® Ridge Vents are installed along the entire ridge of the roof. For Trimline low-profile vents, a 31⁄2” slot should be cut (13⁄4” on each side of ridge). For Trimline high-profile vents a 4” slot should be cut (2” on each side of the ridge). A minimum of 6” must be left uncut on each end of the ridge. Once the slot is cut and the battens are installed, it is time to install the field and trim tiles per the tile manufacturer’s installation instructions. After field tile installation, the ridge now is ready for vent installation. 2. End Cap Installation 4. Cap Tile Installation It is important when installing this vent that you maintain the pitch of the roof. The vent has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded. Install cap tiles per tile manufacturer’s installation instructions. Trimline ridge vent installed in this manner meet the requirement for weather blocking according to Concrete and Clay Roof Tile Design Criteria Installation Manual for Moderate Climate Regions, ICBO ER 6034P. 3. Vent Placement on Ridge Before installing the vent on the ridge, a bead of sealant is required between the roof tile and the under side of the ridge vent. This sealant should fill any voids between the bottom of the vent and the surface of the tile. Caulking and sealants shall be suitable for exterior use and be resistant to weathering. The caulking and the sealants shall be compatible with and adhere to the materials to which they are applied. Check sealant manufacturer’s instructions for compatibility. Roll out or place Trimline vent along the entire length of '#.#06 14#7.- Installation Pull apart a precut section of the foam end cap found with the vent. Using a utility knife, make a cut in the StormStop material 1⁄2” on each side of the vent, back from the end of the section. Using construction adhesive or sealant caulk, coat both sides of the StormStop material where it has been cut back at the end of the vent. Insert the foam end cap with the cut-back StormStop material between the foam end cap and the underside of the vent to assure a weather-tight seal. slot also covering the 6” minimum uncut ridge on both ends. Multiple lengths of vent can be joined by butting the sections tightly together. An end cap should be inserted at the end of each section. 800-438-2920 www.trimline-products.com 23 Cedar Shake and Shingle Roofs 41&7%65 6175' Installation Instructions 1. Ridge Ventilation Slot Preparation The slot may be precut on a new roof before or after shake installation or in a retrofit, the slot can be cut from the roof using a circular saw with a carbide tip blade. (Protective eye goggles should be worn during this process). For Trimline low profile vents, cut a 2” slot (1” on each side of ridge) along the ridge(s). For a roof with a center beam, a 31⁄2” slot should be cut (13⁄4” on each side of ridge). For Trimline high profile vents, cut a 21⁄2” slot (11⁄4” on each side ridge). For center beam applications a 4” slot should be cut (2” on each side of ridge). A minimum of 6” must be left uncut on each end of the ridge. Installation 2. End Cap Installation Pull apart a precut section of the foam end cap found with the vent. For products with StormStop, using a utility knife, make a cut in the StormStop material 1⁄2” on each side, back from the end of the section. Using construction adhesive or sealant caulk, coat both sides of the StormStop material where it has been cut back at the end of the vent. Insert the foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather-tight seal. Attach vent to the roof deck by driving a nail in each of the two corners on both ends of the vent. Also, drive two nails through the vent and foam end cap to hold foam in place on the ends of the ridge only. Nails should penetrate the wood roof deck at least 3⁄4”. It is not recommended to nail vent to ridge prior to cap shake installation. 3. Vent Placement on Ridge Before installing the vent on the ridge, please a bead of sealant on each side of the ridge cut. This sealant should fill any voids between the bottom of the vent and the surface of the cedar shakes. Use either butyl sealant conforming to ASTM C1085; latex sealant 24 800-438-2920 www.trimline-products.com conforming to ASTM C834; silicone sealant complying with ASTM C920 or asphalt roofing cement complying with ASTM D4586. Roll out or place Trimline vent along the entire length of slot also covering the 6” minimum uncut ridge on both ends. When using Rigid Roll products, secure at the lead edge with end cap. Nail should penetrate roof deck a minimum of 3⁄4”. Pull the vent tight and secure at about 10 feet. Pull the rest of the vent tight and secure, inserting the end cap. Multiple lengths of vent can be joined by butting the sections tightly together. Products with StormStop should have an end cap inserted at the end of each section. Note: For “Class A” Installation Only For “Class A” Trimline® vent installation, follow steps 1, 2, 3 as stated above. Once the vent has been installed, use a utility knife with a hook blade and remove the corrugated plastic center section of the vent. Do this for the hip and ridge. This modified installation meets the requirements for UL790 “Class A”, standard installation meets the requirements for UL790 “Class A.” Follow remaining steps 4 as stated. 4. Cap Shake Installation Secure shake caps and vent at the same time using a nail that should penetrate the wood roof deck at least 3⁄4”. It is important when installing this vent that you maintain the pitch of the roof. Trimline EZ-PLUG ® ™ Installation Instructions 41&7%6 6175' Step 1 Step 3 Remove pot vent and trim hole to 8” x 8”. Nail down by hand or nail gun. Clávalo por mano o piótola de clavo. Remueva la tapa del ventilador y corta un hueco 8” x 8”. Step 2 Step 4 Center Trimline® EZ-PLUG in hole. Place 8 nails into flanges as shown at left. Centra el EZPLUG en hueco. Coloque 8 clavos dentro las fianges como se muestra a la izquierda. 1(41/ 64#&+6+10#. 8'06561 4+/.+0' +&)' '065 No está hecho para un agujero más grande de 8” x 8”. Installation Not intended for a hole larger than 8” x 8”. 8 nails minimum per Trimline EZ-PLUG per nailing pattern. 8 clavos mínimo por EZ-PLUG por patrón de clavar. 800-438-2920 www.trimline-products.com 25 Ridge Vent Application in Seismic and Wind Designs According to the APA-The Engineered Wood Association, continuous ridge vents, like Trimline and Trimline Plus, can be used in conjunction with a roof diaphragm and meet the requirements to withstand lateral loads in seismic and high wind designs. Trimline and Trimline Plus can be used in unblocked as well as blocked roof diaphragms. Installation According to the APA with an unblocked diaphragm, there is no requirement for a connection to be made 0$.1%-'& between unsupported +#2*4#)/ edges of adjacent panels. With an unblocked diaphragm-type construction Trimline and Trimline Plus ridge vents can be installed with no modification to the published installation instructions. In an unblocked diaphragm, only the 4-foot wide panel ends occur over and are nailed to common framing. This is the most common type of diaphragm used in standard residential construction. 26 According to the APA Accor with wi a blocked diaphragm, the use of a continuous ridge vent is slightly more challenging because .1%-'& all edges of all +#2*4#)/ adjacent panels must occur over and be attached to common framing. This com additional nailing provides a greater number of fasteners available to transfer shear from one panel to another, thus increasing the overall shear capacity and rigidity or stiffness of the diaphragm. This is as true for the ridge as it is for other panels occurring in a common plane. This can be done by placing blocking in alternating spaces between the rafters or joists. At the location where there is not blocking, the slot at the ridge that is cut for venting, is increased in width to the required opening for proper ventilation. At the location 800-438-2920 www.trimline-products.com where there is blocking, the required nail spacing shall be halved, so that twice as many nails are present to make this connection in every other space. How is proper attic ventilation achieved with alternating blocking in a blocked diaphragm application? With alternating blocking the determining factor for NFA (Net Free Area) is the width of the slot cut at the ridge of the roof. Since the length of the allowable venting area along the ridge is cut in half. The width of the slot is increased to 2.5” to insure proper ventilation. When venting with a blocked diaphragm, warm air travels through the unblocked sections of the ridge, flowing over the blocked sections of the ridge and exiting along the entire length of the ridge vent. The warm air from the attic space will be properly vented using this application. Trimline Low Profile Ridge Vents will provide 12.7-square inches of NFA (Net Free Area) per lineal &)'0#+. foot of the roof in this 52#%+0) 0$.1%-'& application. Trimline Ridge Vents, when properly installed, meet or exceed the requirements of of all allll al .1%-'& nationally recognized #.(1('&)' building codes for 0#+.52#%+0) ventilation. +&)''06 22.+%#6+105 9+6*.1%-'& +#2*)4#/ j16615%#.'k rEMMMg*'0)+0''4'&11&551%+#6+10 Determining Your Ventilation Needs '0)6* +&6* These charts represent the minimum length of Trimline vents, in combination with soffit ventilation, required to properly ventilate your attic space. Determine the square footage of attic space by multiplying length x width of the house. Find your approximate square footage on the chart and read across. Rigid Roll Plus or Rigid Vent Plus Ridge Vent, and the minimum square inches net free area of soffit ventilation required. These charts utilize the F.H.A. Standard for Static Ventilation as found in H.U.D. Requirements for Proper Ventilation - Ref: M.P.S. 403.3. They use the 1:300 ratio (1 sq. ft. of ventilation for every 300 sq. ft. of attic space). Trimline numbers are rounded up to the nearest foot. The numbers in these charts reflect the minimum lineal footage of slot which should be cut into the ridge. For the most aesthetically pleasing roof line possible, it’s recommended that the Trimline ridge vent be installed along the entire ridge and hips of the roof. See page 27 for metric conversions of the charts. The chart will tell you how much net free area is required at the ridge, the recommended footage of Trimline 1941(+.'f+)+&1.. f'06 '06+.#6+10#$.'EfGNN7.' +)*41(+.'f+)+&1.. f'06 '06+.#6+10#$.'EfGNN7.'r 14IfL[6*+%-4+/.+0'+&)''065jEFTK537#4'+0%*'50'6(4''#4'#2'4(116k 14E[6*+%-4+/.+0'+&)''065jEM537#4'+0%*'50'6(4''#4'#2'4(116k r 66+% 37#4' 37#4' 0%*'5 116#)' #6+&)' EXNNN EXENN EXFNN EXGNN EXHNN EXINN EXJNN EXKNN EXLNN EXMNN FXNNN FXENN FXFNN FXGNN FXHNN FHN FJH FLL GEF GGJ GJN GLH HNL HGF HIJ HLN INH IFL IIF IKJ +0T37#4' 0%*'5 1((+6 EL FN FF FH FJ FL GN GE GG GI GK GM HE HF HH FHN FJH FLL GEF GGJ GJN GLH HNL HGF HIJ HLN INH IFL IIF IKJ r17$.'6*'5'07/$'459*'075+0)6*'EfEIN4#6+1T *'%-1761748'06+.#6+10 %#.%7.#61410.+0'#6 999T64+/.+0'g241&7%65T%1/T 66+% 37#4' 37#4' 0%*'5 116#)' #6+&)' EXNNN EXENN EXFNN EXGNN EXHNN EXINN EXJNN EXKNN EXLNN EXMNN FXNNN FXENN FXFNN FXGNN FXHNN FXINN FXJNN FXKNN FXLNN FXMNN GXNNN FHN FJH FLL GEF GGJ GJN GLH HNL HGF HIJ HLN INH IFL IIF IKJ JNN JFH JHL JKF JMJ KFN +0T ''61( +)+&1.. +&)''06 +0T37#4' 0%*'5 1((+6 EG EH EI EJ EL EM FN FE FG FH FI FK FL FM GN GF GG GH GI GK GL FHN FJH FLL GEF GGJ GJN GLH HNL HGF HIJ HLN INH IFL IIF IKJ JNN JFH JHL JKF JMJ KFN 800-438-2920 www.trimline-products.com Installation +0T ''61( +)+&1.. +&)''06 27 Flow-Thru Battens 41&7%6 41& 41&7%6 6175' ™ Installation Instructions Step 1 Unfold Trimline® Flow-Thru Batten to full 8-foot length and align along pre-chalked line. Nail or staple 2" in from the starting edge. Move over to the hinge of the FlowThru Batten and nail or staple 2" from hinge of the fold. Note: Power nail or staple tools can be used to place fasteners. Step 2 Place a nail or staple 10" in from each of the fasteners that have already been placed. Place an additional nail or staple in the middle of the section for a total of 5 fasteners per 4-foot section of batten. Repeat on other side of 4-foot section of the batten. Use this nail or staple pattern when fastening the remaining battens to the roof deck. Fasteners should penetrate the roof deck a minimum of 1⁄2”. See manufacturer's specifications. Note: Use a utility knife when cutting the Flow-Thru Batten to desired length. Step 3 If fasteners are used to secure the tile to the roof, the penetration of the fastener must be into the roof deck for structural hold* according to the manufacturer's specification. *Trimline Flow-Thru Batten cannot be used for structural support of the tile. Flow-Thru Furring Strips Installation ™ Installation Instructions Step 1 Once house wrap has been installed, install a 3⁄4” (19 mm) Trimline Flow-Thru Furring Strip horizontally just below the soffit at the very top of the house wall. Also install a 3⁄4” (19 mm) Trimline Flow-Thru Furring Strip horizontally at the bottom of the wood on the house wall. Step 2 Install 3⁄8” (10 mm) Trimline Flow-Thru Furring Strip every 16” on center using fasteners that penetrate plywood 1⁄2”. 28 800-438-2920 www.trimline-products.com Step 3 41&7%6 Trimline Flow-Thru 6175' Furring Strips should be -\ YYPUN:[YPWZ installed approximately 1” from the edge of the wall. Furring Strips should also be used under trim, in corners and around windows. The furring strips should be installed to support the width of the trim. TM Step 4 Attach siding according to building codes using fasteners long enough to sufficiently penetrate into framing. Soffit Vent 41&7%65 6175' 61 5' Application Locations ET HT IT #44198'4*#0)1((+622.+%#6+10 GT JT +&'8'4*#0)1((+622.+%#6+10 800-438-2920 www.trimline-products.com Installation FT 29 VariaVent Ridge Vent ™ TM 41&7%6 6175' Installation Instructions Step 4 Preparing for Installation Roof tile must be clean and dry before installation. VariaVent Ridge Vent should only be applied when the air temperature is at least 40°F. Assure that a 1” slot has been cut in the roof deck on each side of the center board before beginning installation. We recommend that 6”-12” is left uncut at each end of the ridge. Step 1 Center VariaVent Ridge Vent on top of roof nailing board. Nail VariaVent Ridge Vent at the end of each 4-foot section to hold the vent centered on ridge nailing board. VariaVent Ridge Vent can meet a variety of pitches ranging from 3/12 to 12/12. Use a minimum of a 13⁄4” nail; nail should penetrate nailing board by 3⁄4”. Installation Step 2 Form VariaVent Ridge Vent’s weather-blocking material to tile roof surface. Take care that weather-blocking aluminum area does not press to the surface of the nailing board preventing proper airflow. A 3⁄4” space should be between the weatherblocking material and the center nailing board. Step 3 Remove protective strip from back of adhesive tape on back side of weather blocking. 30 800-438-2920 www.trimline-products.com Press VariaVent Ridge Vent weather blocking into pans of each tile. VariaVent Ridge Vent can elongate to form the barrel to pan closure. Make sure that the edge area of VariaVent Ridge Vent’s weather blocking is thoroughly pressed to tile to assure a weather-tight seal. Step 5 When joining two pieces of VariaVent Ridge Vent together at the ridge, insert the excess StormStop membrane under the new 4-foot section. The aluminum should fit together along the folds. Butt 4-foot vent sections together until they meet and nail in place to center board. Step 6 Cut off excess amount of VariaVent Ridge Vent at end of hip or ridge with knife or sheet metal shears. Step 7 Install cap according to manufacturer’s instructions. VariaBlock VariaBlock TM ™ 41&7%6 6175' Installation Instructions Step 1 Step 4 Center VariaBlock on top of roof nailing board. Nail into the center board every 12” up the hip or ridge. Press in pans of each tile. VariaBlock can elongate 40% from barrel to pan. Make sure the adhesive is pressed firmly to the tile. Step 2 Step 5 Form VariaBlock to tile roof surface. Install from bottom of hip to ridge, overlapping 3” on tile. When putting two rolls of VariaBlock together, overlap the new roll 3” over the roll that has already been applied. Cut off excess VariaBlock at the end of the hip or ridge with a knife or sheet metal shears. The excess material can be used for the next project. Remove protective strip from adhesive tape. 4+/.+0' #4+#.1%%1/'5+0 EI[#0&EEGfH[9+&6*5T 800-438-2920 www.trimline-products.com Installation Step 3 31 Metric Conversion of Trimline Ventilation Product Specs ® 4+/.+0'7.6+1..'062'%5 4+/.+0'+)+&1..2'%5 '0)6* JTNM/1.. +&6*58#+.#$.' EKTKL%/XFFTLJ%/#0&FLTIK%/ '+)*6 EITLK//j19k41(+.' '46+(+'&T TT GFTFJ%/ '0)6* JTNM/1.. +&6*8#+.#$.' FNTMJ%/ '+)*6 EITLK//j19k41(+.' '46+(+'&T TT EJTEG%/j19k41(+.' +6%*'5 GfEF61FNfEF +6%*'5 GfEF61FNfEF #44#06; +('6+/'#07(#%674'4r #44#06; +('6+/'#07(#%674'4r #6'4+#. .#56+% #6'4+#. .#56+% #467/$'45 EKTKL%/gvILKLJX #0#&#EKTKL%/gvGMKHK FFTLJ%/gvILKLI #0#&#FFTLJ%/gvGMKHJ FLTIK%/gvILKLH FLTIK%/9+6*%1+.0#+.5gvGMMEH #0#&#FLTIK%/9+6*%1+.0#+.5gvGMKHH #467/$'4 4+/.+0'1((+664+22'%5 4+/.+0'+)+&'062'%5 '0)6* vJENKE ETFF/'%6+10jEF2'4%#4610k14 FTHH/ 1.&g176'%6+105jJ2'4%#4610k '0)6* ETFF/'%6+10jFH2'4%#4610k +&6*8#+.#$.' FTIH%/ '+)*6 GTLE%/ '46+(+'&T TT EJTEG%/ #44#06; +('6+/'#07(#%674'4r +&6*58#+.#$.' EKTKL%/XFFTLJ%/#0&FLTIK%/ #6'4+#. .#56+% '+)*6 EITLK//j19k14E[j+)*k41(+.' #467/$'4 vFNHJN '46+(+'&T TT GFTFJ%/j19k14EM[j+)*k +6%*'5 #44#06; GfEF61FNfEF +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'45g 1941(+.' EKTKL%/gvIMNLM FFTLJ%/gvIMNME #0#&#FFTLJ%/gvGMKHM FLTIK%/gvIMNMF FLTIK%/9+6*%1+.0#+.5gvGMMEI #0#&#FLTIK%/9+6*%1+.0#+.5gvGMKHL #467/$'45g +)*41(+.' FFTLJ%/gETFF/5'%6+10gvJFHNK FLTIK%/gETFF/5'%6+10gvJFHNJ FLTIK%/gFTHH/5'%6+10gvJHNMG 32 800-438-2920 www.trimline-products.com 4+/.+0' .19g*47#66'02'%5 '0)6* FTHH/ 1.&g176'%6+105jEF2'4%#4610k +&6*8#+.#$.' GTLE%/ '+)*6 ETME%/j19k41(+.' '46+(+'&T TT EHTFF%/ #44#06; +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'4 vJNMEK 4+/.+0'#4+# .#5*2'%5 4+/.+0' .19g*47#0664+22'%5 '0)6* ITEL/1.. GTLE%/ +&6*8#+.#$.' FMTFE%/ #467/$'45 .#%-gvJFJGNX'5'46'&gvJFJGE '0)6* FTJL/ 1.&g176'%6+105jFH2'4%#4610k +&6*8#+.#$.' '+)*6 MTIG//j19k41(+.' #44#06; +('6+/'#07(#%674'4r #6'4+#. .#56+% #467/$'4 vJEENI 4+/.+0' .19g*47 744+0)64+252'%5 4+/.+0'#4+#'06+&)''062'%5 '0)6* ETFF/'%6+10jEN2'4%#4610k +&6*8#+.#$.' EKTKL%/ '0)6* +&6*8#+.#$.' GTLE%/ *+%-0'55 G '46+(+'&T TT G #44#06; '+)*6 EITLK//j19k41(+.' '46+(+'&T TT GFTFJ%/ '06#6'4+#. .#56+% #467/$'45 .#%-gvELNELX#0;10#46*gvELNELX '5'46'&gvELNEL X#0&gvELNEL +('6+/'#07(#%674'4 G 765+&'+/'05+105 GNTEJ%/:GNTEJ%/ 11&'06'4 +/'05+105 EMTNI%/:EMTNI%/ ETEE%/ KTJF/1.. *+%-0'55 +&6*8#+.#$.' FMTLI%/#0&GLTE%/ .#%-gvELGNMX#0;10#46*gvELGEFX '5'46'&gvELGENX#0&gvELGEE #467/$'45g FMTLI% / #467/$'45g GLTE%/ .#%-gvELGEGX'5'46'&gvELGEH rr 14ETI%/6*+%-4+/.+0'+&)''065jLETMG537#4'%/0'6(4''#4'#2'4/'6'4k 66+% 37#4' 4'# GNN GGI GJI GMJ HFJ HIK HJK IEL IHL IKM JNM JHN JKN KEN KGN KJF LNN 37#4' #6+&)' +0T'6'45 1(+)+&1.. 14+)+&'06 +0T37#4' '06+/'6'45 1((+6 IXNNN IXILG JXNLG JXJNN KXENN KXJEJ KXKLG LXJGG MXEGG MXJIN ENXEIN ENXJJJ EEXEJJ EEXLGG EFXEJJ EFXKNN EGXGGG ELTJN FNTKK FFTJG FHTII FJTHE FLTGG FLTMI GFTEE GGTMK GITLM GKTKI GMTJL HETIH HHTNF HITFJ HKTFH HMTJN IXNNN IXILG JXNLG JXJNN KXENN KXJEJ KXKLG LXJGG MXEGG MXJIN ENXEIN ENXJJJ EEXEJJ EEXLGG EFXEJJ EFXKNN EGXGGG fL[gvJEENIXGfH[gvHNFHK 4+/.+0'g2'%5 '0)6* r .#56+% #467/$'45 1941(+.'f+)+&1.. f'06 '06+.#6+10#$.'EfGNN7.' fL[#0&GfH[ fL[gFTL[#0&GfH[gITJ[ #6'4+#. 4+/.+0'#4+#.1%-2'%5 FTJL/ 1.&g176'%6+105jFH2'4%#4610k #6'4+#. .#56+%#0& ETEE%/5*'#6+0) 1:1(FH#467/$'4 vMKNHJ +)*41(+.'f+)+&1.. f'06 '06+.#6+10#$.'EfGNN7.' rr 14FTIH%/6*+%-4+/.+0'+&)''065jEFFTILNH537#4'%/0'6(4''#4'#2'4/'6'4k 66+% 37#4' 4'# GNN GGI GJI GMJ HFJ HIK HJK IEL IHL IKM JNM JHN JKN KEN KGN KJF LNN 37#4' #6+&)' +0T'6'45 1(+)+&1.. 14+)+&'06 +0T37#4' '06+/'6'45 1((+6 IXNNN IXILG JXNLG JXJNN KXENN KXJEJ KXKLG LXJGG MXEGG MXJIN ENXEIN ENXJJJ EEXEJJ EEXLGG EFXEJJ EFXKNN EGXGGG EFTHG EGTLL EITEF EJTHE EKTJI ELTMG EMTGI FETHJ FFTKE FGTMM FITFG FJTIF FKTKJ FMTHF GNTFI GETIK GGTEI IXNNN IXILG JXNLG JXJNN KXENN KXJEJ KXKLG LXJGG MXEGG MXJIN ENXEIN ENXJJJ EEXEJJ EEXLGG EFXEJJ EFXKNN EGXGGG rr17$.'6*'5'07/$'459*'075+0)6*'EfEIN4#6+1T r''2#)'GH(14%1/2.'6'9#44#06;T 800-438-2920 www.trimline-products.com 33 Trimline® Building Products Lifetime Manufacturer’s Warranty Rigid Roll® Plus, Rigid Vent Plus™, Trimline Multi Roll™ Vent, VariaVent™, VariaBlock™, VariaFlash™ and Soffit Ventilation Products Limited Warranty. Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products are warranted to you, the original purchaser, against defects in materials and workmanship in manufacture under normal use and service, provided the vent has been installed in strict accordance with the Trimline® installation instructions, and under normal use and service, subject to the conditions set forth below, to be free of defects in materials and workmanship in manufacture for lifetime from the date of purchase. This Warranty is NOT transferable under any circumstances and applies only to the original purchaser of the Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products. The warranty period starts on the date of purchase by the original purchaser and terminates on the earlier of the date of sale of the property upon which Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products are applied or removal of your Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products from the property on which it is first installed. Remedies. During this Limited Warranty period, should any defect in materials and workmanship in manufacture occur that directly results in damage or loss to the Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products, and the product is deemed to be defective by Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products, without charge to you, for up to the lifetime of the product following the date of purchase. Limitations of Coverage. Trimline will NOT be liable for, and this Warranty does NOT apply to: 1. Failure, defect, damage or loss resulting from misuse, abuse, neglect or improper installation not in strict adherence to the manufacturer’s written instructions. 2. Damages to your ridge vent beyond normal use including, but not limited to: a. Fire, flood, hail, lightning, windstorm, tornado, earthquake, hurricane, other violent storms or natural disasters, and Acts of God. b. Improper storage or handling of the ridge vent. c. Defect in or misapplication of materials used to install ridge vent. d. Alteration, unreasonable use, accident or negligence. e. Settlement, movement or damage to the interior or exterior of the building, foundation or any property contained therein. 34 800-438-2920 www.trimline-products.com f. Any cause other than manufacturing defects. g. Labor costs incurred. h. Damages resulting from the removal or reinstallation. Notification of Claims. In order to recover under this limited warranty, you must submit any claim under this Warranty in writing within sixty (60) days of damage or loss, explaining the nature of the alleged defect, and sent with proof of purchase, containing a description of the product, the purchase date and any applicable serial numbers, to establish that you are the original purchaser, to Trimline Building Products, 705 Pennsylvania Avenue South, Minneapolis, MN 55426, within thirty (30) days of discovery of the alleged defect. Trimline Building Products reserves the right of inspection of the defective Trimline Ridge Vent PLUS, Trimline Multi Roll Vent, VariaVent, VariaBlock, VariaFlash and Soffit ventilation products, before having any obligation under this limited warranty, by an authorized representative prior to any settlement of a claim and the purchaser must allow reasonable investigation of the claim. Trimline Building Products will evaluate the claim and resolve it in accordance with the terms of this Warranty. Other Conditions. This Limited Warranty is exclusive. THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TRIMLINE SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF TRIMLINE CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Trimline Building Products makes no other representations or warranty of any kind other than stated herein. No representative of Trimline Building Products or its distributors or dealers is authorized to make any change or modification to this Warranty. This lifetime limited manufacturer’s warranty applies only to Trimline Ridge Vent PLUS, VariaVent and VariaBlock ventilation products. TRIMLINE IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOST PROFITS, DOWNTIME, GOODWILL, DAMAGE TO OR REPLACEMENT OF EQUIPMENT AND PROPERTY. Some states or provinces do not allow exclusion or limitation of incidental or consequential damage, or exclusions or limitations of the duration of implied warranties or conditions, so such exclusions or limitations may not apply specifically to you. This Limited Warranty gives you specific legal rights and you may have other rights which vary from state to state. Trimline® Ridge Vent Certification Certification Burning Brand Test Class A & C - UL790 Testing • Spread Flame Test - UL790 • Wind-Driven Rain Test - UL790 1.5” per sq. ft. per hr. 40-60 mph • Witness manufacturing and quality control test of ridge vent • FL# 4330 Certification Certified for Confidence in Testing Long-Lasting SS S SS Performance SS S S S • NFVA 4.2 Net Free Ventilation Area determined in Section 5.1 • UBC 26-6/ASTM D1929 (1975) Self-Ignition Section 4.3.1 Approved Plastic • UBC 26-7 (Burn Rate C1, C2) Section 4.3.1 Approved Plastics • Dust Exposure Test: Section 5.2. The pressure drop shall be used to determine the NFVA in accordance with Section 4.2.2 (Airflow & Dust Confirmed NFVA) • Temperature Cycling: Section 5.3 • Weathering Test: Section 5.4 (-40 to 180 degrees) • Resistance to Wind-Driven Rain and Snow: Section 1505.3 of building code • Test of the attic vent in accordance with Dade County Protocol PA100(A)-95 • Section 4.4.4 of AC132 6” per hour @ 35 mph, Snow 50, 70, 90, 100 mph • Quality Control: documented quality control program, per Sections 1 & 2 of Acceptance Criteria for Quality Control Manuals (AC10) • Wind-Driven Rain and Simulated Snow Infiltration Test 6” @ 50-100 mph • ASTM E330 static pressure structural uplift performance test. 72, 108, 150 psf • ASTM D3746 impact resistance testing • NFVA calculations from labs for Average Net Free Ventilation Area SSSSSS S S AC132 Acceptance Criteria for Attic Vents (65 Industry SSSSS S SS S RIDGE VENTS - CLASS A or C AS TO AN EXTERNAL FIRE EXPOSURE ONLY WHEN INSTALLED IN ACCORDANCE WITH INSTRUCTIONS PROVIDED WITH RIDGE VENTS 8FA1 Certification Static Pressure Uplift Test ASTM E330 72, 108, 150 psf Testing • A copy of ICBO ES Report #ER-5417 • A copy of our NOA Report No. 02-0129.05 Miami-Dade County, Florida • Net Free Ventilation Area Data Certification MIAMI DADE COUNTY APPROVED 'LYHUVL3ODVW3URGXFWV %DOGZ\Q06 0LDPL'DGH&RXQW\)ORULGD3URGXFW&RQWURO$SSURYHG 12$1R¬([SLUDWLRQ'DWH Miami-Dade Building Code Compliance Office - (NOA) Notice of Acceptance Criteria for 11” Shingle-Over Ridge Vents Testing • Wind-Driven Rain per PA100(A) 8.8” water @ 110 mph • ASTM D1929 (Self-Ignition Temp 650 F) • ASTM D2843 (Smoke Density) • ASTM D635 (Burn Rate C1, C2) )/)/5 800-438-2920 www.trimline-products.com 35 Trimline® Ridge Vent FAQs Q. How does StormStop® work? A. The membrane material used in Rigid Roll PLUS™ is a spun-bound non-absorbent plastic. Twenty nine percent of our membrane is fiber. The other seventy-one percent is open. This lightweight membrane makeup allows air to pass through but stops water. Water pools on the surface of the membrane but is not allowed to penetrate it. environment in which it operates. A baffled venting system only operates at its optimum efficiency when the wind passes perpendicularly over the baffle at a precise angle. If there is no wind over the baffle it does not aid in venting of the roof. In addition, your ridgeline has to be facing the way the wind blows for the baffle to perform. A baffle alone will not provide adequate continuous ridge ventilation; it must be a part of a balanced system. Q. Will StormStop reduce airflow? A. Actually, the airflow of a ventilation system is determined by the Net Free Area of the vent, the slot width and the ventilation at the eave or soffit (a balanced system). The recommended slot width for installation of Rigid Roll PLUS™, when used with a balanced system, provides adequate airflow for efficient ventilation. Q. How easy is installation? A. The product easily rolls out and is quick and easy to install using a coil nail gun. There is one simple additional step when inserting end-caps. A small cut in the membrane must be made to assure a proper seal at the end of the vent. See page 14. Q. What is the NFA of the product? A. The Net Free Area of the product is 12.7 inches per lineal foot for the low profile product and 19 inches per lineal foot for the high profile product. Q. Has the product been tested? A. Yes! The product has been put trough rigorous research and development testing at Architectural Testing Institute in York Pennsylvania. The results: Q. Will the StormStop filter clog? A. Actually, the material is not a filter, but is a special membrane. Unlike products with a filter, the material is non-porous and will not allow matter such as dirt or loose insulation to lodge within it. Products that actually use a filter material are susceptible to clogging. • It withstood tests similar to DADE County protocol of 8.8 inches of rain per hour with 110-MPH winds and easily passed. Q. You do not have baffles, so will this product perform as well as baffled products? A. The most crucial element to the performance of a ventilation system is that it is in balance. If an attic has a properly balanced system, the airflow will move from the eaves and the bottom of the attic to the top, pushing out heat and moisture in a natural flow using air pressure, thermal effect and diffusion. If the system were to be unbalanced, and the NFA at the ridge is higher than at the eave, a reverse airflow can occur causing an opposite effect to what is desired. Baffles have no effect on achieving a balanced system. For a system to be in balance there must be an equal or greater amount of intake at the eaves than what is being exhausted at the ridge. • It also passed the ICC snow simulation test at 35 MPH and 70 MPH with no infiltration. Trimline Ridge Vents meet the conditions of acceptance of the Dust Exposure Test with no reduction in airflow. • Trimline Ridge Vents are certified for performance by Miami-Dade, Building Officials and Code Administrators International, International Conference of Building Officials, International Code Council, Texas Department of Insurance and Underwriters Laboratories Class A or C. Q. What pitches can it be used on? A. Rigid Roll and Rigid Vent PLUS™ can be used 3/12-20/12. Q. Can this product be used on hip applications? A. Yes, the same Trimline Ridge Vent that is used on the ridge will work well in hip applications. See page 18. Q. What other reasons is a non-baffled product better than a baffled product? A. Baffles are unattractive and easily seen on the roof. In addition, plastic baffles can break off or deteriorate over time. Baffles also are susceptible to clogging from leaves and other debris. Q. Do Trimline Ridge Vents work with any other applications? A. Trimline Ridge Vents work on hip, and Trimline Multi Roll™ Vents work on eave intake, ridge exhaust and shed applications. Trimline Ridge Vents also work under various types of roofing materials such as flat tile, cedar shakes and shingles, stone-coated steel and metal. See pages 17-24. Q. What about the Bernoulli effect? A. The Bernoulli effect has to do with wind passing over an object. When venting, a baffle is only as effective as the Q. What kind of warranty do Trimline Products have? A. Rigid Roll® PLUS and Rigid Vent PLUS™ carry a manufacturer’s limited lifetime warranty! See page 34. 36 800-438-2920 www.trimline-products.com Trimline® Building Products 705 Pennsylvania Avenue Minneapolis, MN 55426 800-438-2920 FAX 763-540-9709 www.trimline-products.com 10-10