Upblast Roof Exhausters
Transcription
Upblast Roof Exhausters
FUMEX Upblast Roof Exhausters Moving Your Way TABLE OF CONTENTS Introduction, Certifications & Listings 3 Features & Benefits 4 Options & Accessories 5 Motor Availability 8 Direct Drive Dimensional & Performance Data 10 Belt Drive Dimensional & Performance Data 13 Engineering Specifications 29 BULLETIN FX14 PennBarry | Your Single Source for Commercial & Industrial Supply & Exhaust Fans | www.pennbarry.com Fumex | FX INTRODUCTION Fumex Series of Centrifugal Fans Fumex centrifugal fans are designed for medium to high pressure applications. They can be either roof or wall mounted. While suitable for general ventilation, Fumex fans are specifically designed to discharge contaminated or grease-laden air or fumes up and away from building surfaces. The optional “Fatrap” (UL762) restaurant grease exhaust configuration (see Fatrap Configuration) makes Fumex fans particularly suited for all food service applications and chemical fume hoods. The optional heat and smoke removal configuration (see Smoke Removal) makes Fumex fans particularly suited for heat and smoke control systems. The optional high wind construction makes Fumex Fans particularly suited for high wind hurricane zones. Fumex fans are available in a range of capacities. Belt Drive Fumex with Fatrap option (left) and Direct Drive Fumex (below). Fumex fans feature a weather-resistant seamless spun aluminum housing which provides ample drainage and works in conjunction with a patented wheel design and deeply spun inlets to provide smooth quiet airflow through the ventilator. The centrifugal wheels are aluminum, non-overloading, backward inclined, robotically welded, and dynamically balanced. Fumex Direct Drive Series Model: FX (V/S/R/Q/Q1/Q2) • Static pressure up to 1.5 in. wg. • Flow capacity up to 4,489 CFM. • Fatrap (FT) option available on sizes 13, 16, and 18. • High Wind Construction (-HW) option available. Fumex Standard Duty Belt Drive Series Model: FX (B) • Static pressure up to 2.5 in. wg. • Flow capacity up to 21,511 CFM. • Fatrap (FT) option available. • Heat & Smoke Removal (-HS) option available. • High Wind Construction (-HW) option available. Fumex High Pressure Belt Drive Series Model: FX (BH) • Static pressure up to 4 in. wg. • Flow capacity up to 9,920 CFM. • Fatrap (FT) option available. • Heat & Smoke Removal (-HS) option available. • High Wind Construction (-HW) option available. Fumex High Capacity Belt Drive Series Model: FMX (B) ©PENNBARRY 2014 • Static pressure up to 1.5 in. wg. • Flow capacity up to 25,035 CFM. www.PennBarry.com | Moving Your Way CERTIFICATIONS & LISTINGS Fumex Direct & Belt Drive Fans PennBarry certifies that the Fumex direct drive and belt drive models FX, FXB, FXBH, and FXBHFT shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Fumex High Capacity Belt Drive Fans PennBarry certifies that the Fumex belt drive model FMXB shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. UL and cUL Certification Fumex fans carry the UL label, UL 705 (ZACT), File #E28413. Fumex fans with the “Fatrap” option are UL 762 (YZHW) listed under file #MH10684. Fumex fans with the heat and smoke removal option are UL listed under file #MH19473. 3 Fumex | FX FEATURES & BENEFITS Motor Selection Vibration Isolators Reverse Venturi Both direct drive and belt drive models are available with a wide range of voltages and enclosures (see Motor Selection for a complete listing). Standard belt drive Open Drip Proof (ODP) ball bearing motors are selected using a conservative portion of the NEMA service factor. Standard direct drive ODP motors have Class B insulation and internal overload protection. Overload protection is available as an option on belt drive models. Each size is carefully engineered to match the motor to the wheel capacity. Multidirectional, rubber-in-shear vibration isolators mitigate residual vibration transmission from the unit to the building. Reverse venturi reduces turbulence and improves distribution of the air as it enters the wheel inlet and is “captured” by the blades. Internal Wiring All direct and belt drive models with ODP motors feature a polarized disconnect plug which is factory wired from the motor to the junction box. This provides a positive method of electric shut-off as required by most codes without requiring the traditional disconnect switch. (See Options & Accessories for optional NEMA wiring and disconnect devices.) Sound Performance Fumex units deliver outstanding air performance with minimal noise and have the lowest AMCA licensed sound performance in the industry. Curb Caps (Base) Curb caps for direct drive and standard duty belt drive models are available in galvanized steel (standard) or aluminum (optional). Curb caps for high capacity belt drive models are available only in aluminum. All curb caps have fully welded corners and are pre-punched to ensure a leak-tight and easy installation. Forced Motor Cooling Motors and drive components are located out of the airstream in a separate compartment. A cooling tube between the motor dome and discharge apron enables fresh air to be drawn into the motor housing during fan operation. This positive cooling promotes longer life for motor and drive components. Easy Maintenance Access 4 Durable housings of spun aluminum have a high strength-to-weight ratio and incorporate a rolled bead for additional strength. There are no welds to break or seams to leak. The heavy-gauge motor mounting platform provides positive rigidity between all components of the power train assembly. Internal Bracing Tri-Strut™ supports transfer the weight of the motor mounting platform directly to the curb mounting surface. The aluminum spun housing, therefore, is not used to support any weight. For grease laden applications, there is less surface for grease build-up during normal operation. Solid Steel Shafts Sized so the first critical speed is a minimum of 130% of maximum cataloged operating speed, shafts are precision ground, and polished. Self-Aligning Bearings Heavy-duty bearings are sized for a minimum L50 life in excess of 200,000 hours of operation. 100% factory tested, they are designed for air handling applications. Drives and Belts Pulleys are pre-set to the specified RPM. Cast iron variable pitch pulleys are adjustable, allowing for field balancing based on actual field conditions. All pulleys are sized for at least 150% of the driven horsepower. Conduit Both direct and belt drive units include a large 1” nominal conduit chase (not available on heat and smoke removal units; wiring is run via the cooling tubes) for easy installation of wiring from the motor dome to below the curb cap. Fatrap units are factory wired to an external NEMA 3R junction box. Wheels Fumex fans offer patented wheel designs. Carefully matched, highly-tooled venturis enhance the performance of these backward inclined and non-overloading centrifugal wheels. Made of advanced aluminum alloys, the various wheel components provide superior strength and durability, as well as spark resistant construction. The heat and smoke removal configuration utilizes steel construction. Silent Wheel (Direct Drive) • Blades’ highly curved leading edge provide unsurpassed low sound numbers with excellent air performance. • Back plate and inlet are stamped for consistency, plus dynamic balancing assure smooth, vibration-free operation. • Riveted or riveted and welded construction ensure superior dependability over other wheel designs. Standard Duty, All Welded Wheel (Standard Duty & High Pressure Belt Drive) • Blades are curved for improved air performance while increasing their strength and rigidity. • Back plate and inlet are stamped for consistency. They include a perimeter rim which enhances strength and improves balancing. • Wheel assembly is robotically welded to provide extremely durable and consistent performance. • Wheel is dynamically balanced. Balancing weights are mechanically attached to the inside of the rims of both the back plate and wheel inlet. This allows a precise placement of the weights anywhere within a full 360º range on two separate planes, without the possibility of detachment. www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 By removing the fasteners, the motor dome lifts off for complete access to all the drive components. Structural Integrity Fumex | FX OPTIONS & ACCESSORIES Finishes Internal Wiring Speed Controllers Coatings such as Polyester Powder Coat, Epoxy Powder Coat, Phenolic Epoxy Powder Coat, and others are available. See the coatings brochure for details. NEMA 3R wiring is available for both direct and belt drive models. The Lek-TrolTM controller allows adjustment in speed to a maximum of 50% reduction, which results in a very cost effective means for system balancing. The device can be located under the fan dome to prevent unauthorized tampering or on the wall for ease of operation by the building occupants. (Available on direct drive units with ODP motors and some select TE motors. See reference table under Motor Availability) The 12” high mounting pedestal, available in aluminum or galvanized steel, incorporates a removable access panel for easy inspection and service of motor operated back draft dampers. It provides solid ventilator support and a weather resistant seal that does not injure or disturb flashing. This item should not be used with Fatrap units. Back draft dampers are available for either gravity or motorized operation (motor kit optional). Dampers feature square galvanized steel frame, multi-leaf, roll formed aluminum blades with nylon bearings. Back draft dampers should not be used when venting kitchen hoods. NFPA 96 installations do not allow the use of dampers. The requirements of local codes must be reviewed to determine if there are any conflicts. Hinged Sub-Base Safety Disconnect Switch Mounting Pedestal Hinged sub-bases provide access to the curb well for damper service or clean out for grease applications. Constructed with a rust proof hinge arrangement and low height (3 ½”) the assembly is easily manipulated and reduces the impact on overall installation height. This accessory is available for use with most all models for either factory built or existing roof curbs. Floating Hinge Kit A floating hinge kit is also available for field installation. This assembly connects the exhauster directly to the roof curb and provides the same level of access as the hinged sub-base. Fumex Base Floating Hinge Plate Back Plate (Inside Curb/Pedestal) Ventilator Curb/Pedestal Bushing Aluminum Bird & Insect Screen ©PENNBARRY 2014 Backdraft Dampers Bird screens are available for all direct and belt drive models. An aluminum insect screen with a smaller mesh than the standard bird screen is also available. However, please note that NFPA 96 installations do not allow the use of bird or insect screens. The requirements of local codes must be reviewed to determine if there are any conflicts. www.PennBarry.com | Moving Your Way Safety disconnect switches are available to allow positive electrical shutoff and safety. Switches are factory mounted when factory wiring is requested. Wiring is only run from the motor to the junction box. (Factory wiring of explosion proof applications is not available.) A wide range of NEMA rated enclosures with disconnect switches are available for indoor, outdoor, and explosion proof installations. Disconnects are to be field wired by a licensed electrician. Firestat Switch Firestat switch automatically disconnects the unit when the temperature of the air being exhausted exceeds a preset rating. Time-Delay Switch (Selected direct drive models only) The Airminder Model AM12 switch is a UL recognized and CSA certified time-delay relay that operates both the fan and room light to ventilate an area even after the occupants depart. In the “On” position, the Airminder turns the light and fan on immediately. In the “Off” position, the light goes off immediately and the fan is in operation for a period of time as preset from 1 to 60 minutes. Suitable only for 1/3 HP maximum at 120/1/60. Automatic Belt Tensioner The factory mounted Automatic Belt Tensioner accessory eliminates the need for re-tensioning the belt after start-up. It is constructed from 10 gage galvanized steel and incorporates five torsion springs to automatically position the motor and maintain proper belt tension. Additional benefits include reduced belt and pulley wear and simplified belt replacement without tools. The Automatic Belt Tensioner is available for Fumex models FX08B, FX10B, FX12BH, FX13B, FX13BHFT and FX14B with 1/4, 1/2, 3/4, and 1 HP ODP motors. It can also be used with 1.5 HP, 3-phase ODP motors. Spark Resistant Construction AMCA ‘B’ construction is available as standard construction on direct drive units and as an option on belt drive units (not available on heat and smoke removal units). If required, an explosion proof motor and disconnect may be selected as options. Wall Mounting This option is provided as a separate product line, whose models include a “W” prefix. Product line includes models up to size 24, motors up to 2HP, and round bases (not available on heat and smoke removal units). Prefabricated Curb A variety of sizes of prefabricated roof curbs are available. Galvanized steel unibeam curbs are the most popular. For a complete listing of all curb types and sizes available, see the latest PennBarry Ventilation Curb brochure. Please note that NFPA 96 installations require a specific curb height. See Fatrap configuration on the next page. 5 Fumex | FX OPTIONS & ACCESSORIES Fatrap Configuration Fumex Curb Fatrap configured fans are ideal for use in commercial kitchens over grilles, charcoal broilers, deep fat fryers, steam tables, ranges, dishwashers, and other appliances. Fumex fans are specially configured for food service applications with the addition of a group of accessories that either meets a requirement or eases installation requirements according to NFPA 96. NFPA 96 “Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations” is the generally recognized authority nationwide for restaurant installation requirements. However, local codes may vary. T (sq.) 1 1/2" H 18" MIN. Vented Self Standard Flashing w/Cant Ro (sq.) A (sq.) Included in the units are the following. Damper Size SQ Galv. Steel Gauge 9 8.75 18 11.5 11.25 18 11.5 11.25 18 25 11.5 11.25 18 19 27 16 15.75 18 27 35 20 19.75 18 24.75 23.25 31.25 16 15.75 18 FX12BH 24.75 23.25 31.25 16 15.75 18 FX13BHFT 24.75 23.25 31.25 16 15.75 18 FX16B and FX18B 28.5 27 35 20 19.75 18 FX18BH 28.5 27 35 20 19.75 18 FX24B 33.5 32 40 25 24.75 18 FX24BH 33.5 32 40 25 24.75 18 FX27B and FX30B 36.5 35 43 28 27.75 18 FX36B 44.5 43 51 36 35.5 18 FMX50B 59 57.5 65.5 50 49.5 18 E(4) SQ T(2) SQ A SQ FX08S/R 18.5 17 25 FX10S/R 18.5 17 25 FX11V/S/R/Q 18.5 17 25 FX13V/S/R/Q 18.5 17 FX16V/S/R/Q1/Q2 20.5 FX18V 28.5 FX08B to FX14B Model Ro(3) SQ Standard heights “H” are 8”, 12”, and 18” including wood nailer. ”T” dimension of curb is 1 1/2” less than the dimension of inside base of fan (“E”). “Ro” refers to Roof Opening. “E” dimension is inside base of fan. For FT (Fatrap) units, curbs are cantless, 18” high and optionally vented. Exploded View SAFETY DISCONNECT SWITCH ALUMINUM BIRD AND INSECT SCREEN HINGED SUB-BASE PREFABRICATED CURB • UL 762 Listing: Fatrap configured Fumex fans are listed at 400°F — 100°F higher than UL requirements. The high temperature rating is the result of the fan’s highly efficient forced motor cooling capability. Three direct drive (sizes 13 – 18) and all belt drive models are listed. • Pre-wired Junction Box: A weather-proof junction box is factory wired and mounted to the housing exterior. An appropriately sized disconnect switch is commonly selected as an additional option. These items meet the code requirements for positive electric shut-off. • Grease Collector/Separator Box: Designed for easy installation, the grease is routed from a single swiveling collection spout to an amply sized durable galvanized steel box, trapping grease and residue, and avoiding discharge onto the roof surface. Additionally, these boxes separate the water from the grease, prolonging the time required between periodic maintenance. Additional Fatrap Accessories Ventilated Curbs and Pedestals: For buildings two stories or higher NFPA 96 requires the use of ventilated mounting curbs or pedestals to provide an approved arrangement for connecting a range hood and duct work to the roof fan. PennBarry’s ventilated mounting curbs and pedestals, 18” high, comply with that standard when properly installed. Ventilated curbs have a flat mounting flange for fastening directly to the roof deck. This flange should be securely fastened and flashed to ensure weather tightness. Ventilated pedestals are designed to fit on an existing curb. They provide cap flashing when so installed. BACKDRAFT DAMPER 6 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 Make-Up Air Units (Suplex): Fumex fans with the Fatrap configuration can be combined with a PennBarry FS Muffan fan to create an integrated unit called the Suplex. The Fumex handles the required air flow to be exhausted while the Muffan provides an appropriate amount of supply make-up air. The modular design of the Suplex means that just one roof opening is needed for both the exhaust and supply ducts. An insulated shield divides the base to separate the exhaust and make-up air compartments, and prevents heat transfer between hot exhaust air and fresh filtered air. This results in a complete air-tight seal between the hood and exhaust fan. Fumex | FX OPTIONS & ACCESSORIES Heat & Smoke Removal Configuration While Fumex fans are commonly used for general ventilation, they are also designed to discharge contaminated or grease-laden air or fumes up and away from building surfaces with the Fatrap option and when equipped with the Heat and Smoke Removal option, this series of fans incorporates features exclusively designed to exhaust heat and smoke in the event of fire. During these emergencies, the fans are designed to operate at the temperature and time limits stated below. To maintain power to these fans during emergencies, special consideration must be made for field power supply. In the event of an emergency, if power is maintained, the units will operate for the times and temperatures indicated, after which they will continue to operate until they are destroyed by the extreme temperature generated during an actual fire, or their roof structure collapses. ADDITIONAL COOLING TUBE STEEL WHEEL PREFABRICATED CURB For smoke control systems, Heat and Smoke Removal configured fans are listed per UL for emergency smoke removal, referencing UL705, UL793, Industrial Risk Insurers (IRI), and Southern Building Code Congress International (SBCCI). The UL standard requires the fan to run at 500°F for 4 hours (IRI) and 1000°F for 15 minutes (SBCCI). PennBarry Heat and Smoke Removal configured Fumex units are listed at 500°F for 4 hours and 1000°F for 1 hour. The additional 45 minutes at 1000°F will buy precious time in the event of a fire. Steel Wheel: The wheel is a standard duty, all welded wheel (standard duty and high pressure belt drive). The blades are curved for improved air performance while increasing their strength and rigidity. The wheel assembly is fully welded to provide extremely durable and consistent performance. The wheel is dynamically balanced. Balancing weights are mechanically attached to the inside of the rims of both the back plate and wheel inlet. This allows a precise placement of the weights anywhere within a full 360° range on two separate planes, without the possibility of detachment. Forced Motor Cooling: Motors and drive components are located out of the airstream in a separate compartment. Two cooling tubes are located between the motor dome and discharge apron which enables fresh air to be drawn into the motor compartment during fan operation. This allows the cooler outside air to wash over the motor and bearings. This positive cooling promotes longer life for the motor and drive components. High Wind Construction High wind construction Fumex fans are specifically designed for high wind hurricane zones (HWHZ). The Fumex models are designed to withstand 150 MPH winds in accordance with Miami-Dade and Florida Building Code standards. The units are 3rd party tested and certified through a 3rd party Professional Engineer (P.E.) to meet these strict standards. Installation details are provided and since there are no tie downs or external braces required for attaching the unit to the roof or curb this makes installation simple and easy. A wide range is offered to meet all of your ventilation needs which includes all belt and direct drive sizes 36 and under. ©PENNBARRY 2014 Product Certifications: •Miami-Dade NOA # 14-0311.03 •Florida Product Approval #12339 •Texas Department of Insurance # RV-48 www.PennBarry.com | Moving Your Way Belt Drive Fumex Cutaway Direct Drive Fumex Cutaway 7 Fumex | FX MOTOR AVAILABILITY Model Green Plus Electronically Commutated Motor The Green Plus (GP) option utilizes EC motors to provide significantly greater efficiency, flexibility, and controllability over standard direct drive permanent split capacitor (PSC) motors. Using the included potentiometer, the Green Plus motors can be turned down to as low as 80% the max operating speed while maintaining 90% efficiency through the operating range. Additionally, the Green Plus can accept 0-10V input to tie to building management systems, allowing for savings in not only direct fan energy consumption but reducing the exhaust of conditioned air during off peak hours as well. All Green Plus motors come in open enclosure for usage with 115-208/230V, single phase, 60 Hz applications. NEMA Motor This chart summarizes the largest allowable NEMA frame sizes for motors used on belt drive models. Largest Available NEMA Frame Size per Model Model Max. Frame Size Model Max. Frame Size FX08B 56 FX18B 145T FX10B 56 FX18BH 145T FX12BH 56 FX24B 184T FX13B 56 FX24BH 184T FX13BHFT 56 FX27B/FX30B 184T FX14B 56 FX36B 213T FX16B 145T FMX50B 215T At PennBarry’s option, large frame motors may be removed after testing and shipped separately. Contact the factory for special application motor availability. WFX/FX Size Tap ECM HP 08 S 0.33 08 R 0.33 10 S 0.33 10 R 0.33 11 V 0.33 11 S 0.33 11 R 0.33 11 Q 0.33 13 V 0.33 13 S 0.33 13 R 0.33 13 Q 0.33 16 V 0.33 16 S 0.50 16 R 0.50 16 Q1 0.50 16 Q2 0.75 18 V 0.75 Available Lek-Trol™ Speed Controls 60 Hz Model ODP 50 Hz Totally Enclosed Totally Enclosed 115V 115V 200V 208V 230V 110V 220V 240V FX08S - - - - - - - - FX08R LT25 - - - - - - - FX10S - - - - - - - - FX10R LT30 LT30 LT35 LT35 LT35 LT30 LT35 LT35 FX11V - - - - - - - - FX11S - - - - - - - - FX11R LT30 - - - - - - - FX11Q LT50 - - - - - - - FX13V - - - - - - - - - - - - - - - - LT30 LT30 LT35 LT35 LT35 LT50 LT35 LT35 Variable Speed Motor Control FX13Q LT45 LT50 LT35 LT35 LT35 LT50 LT35 LT35 PennBarry offers Lek-Trol™ solid state controllers to alter the high speed of most direct drive motors by as much as 50%. If variable speed is required, check the Lek-Trol™ availability table below to verify that controllers exist for the fan model selected. Remember, Lek-Trol™ controllers are currently only available for direct drive motors including all standard Open Drip Proof (ODP) 60 Hz motors. Not all totally enclosed motors are currently available with variable speed control. Inverter rated motors suitable for use with variable frequency drives can be supplied for belt drive models. Contact your local PennBarry representative for availability. FX16V - - - - - - - - FX16S - - - - - - - - FX16R LT50 - - - - - - - FX16Q1 LT40 - - - - - - - FX16Q2 LT75 - - - - - - - FX18V LT60 - - - - - - - 8 Lek-Trols™ indicated for multi-speed models (eg., FX16V/S/R) are applicable only for the high speed. Do not use on low or medium speed for multi-speed models. Items noted with ( - ) are not applicable. www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 FX13S FX13R Fumex | FX MOTOR AVAILABILITY Direct Drive Motor Availability The following chart lists the various motor options available for each of the direct drive fan models. Once a fan model is selected, this chart can be used to determine if a suitable motor is available. (If not, another selection may have to be made from the fan performance charts). Look under the nominal RPM heading to determine which fans have 2-speed and 3-speed motors. Nominal RPM Model 1 Phase 1050 V 1300 S 1550 R 1725 Q FX08S/R - x x FX10S/R - x x FX11V/S/R x x FX11Q - FX13V/S/R 115 Volts 200 - 240 Volts Open Drip Proof Totally Enclosed Explosion Proof - yes yes (1) - yes yes (1) x - yes - - x x x x FX13Q - - - FX16V/S/R x x FX16Q1 - - FX16Q2 - FX18V x Totally Enclosed 50 hz 50 C Ambient Explosion Proof (4) - yes (1) yes (1) yes (1) - - yes (1) yes (1) yes (1) - yes (1) - yes (1) yes (1) yes (1) - yes yes yes yes yes yes yes (5) - yes yes (1) - yes (1) yes (1) yes (1) - x yes yes yes yes yes yes yes (5) x - yes yes (1) - yes (1) yes (1) yes (1) - - x (3) yes - - - - - - - - x yes yes yes yes yes yes yes (5) - - - yes - - - - - - Nominal RPM Open Drip Proof Use TE Motors 3 Phase Model 200 - 460 Volts (2) 1050 V 1300 S 1550 R 1725 Q Totally Enclosed 50 hz 50 C Ambient Explosion Proof (4) FX08S/R - x x - - - - - FX10S/R - x x - - - - - FX11V/S/R x x x - - - - - FX11Q - - - x - - - yes (6) FX13V/S/R x x x - FX13Q - - - x FX16V/S/R x x x FX16Q1 - - - FX16Q2 - - - FX18V x - - Open Drip Proof Use TE Motors - - - - yes yes yes yes (6) - - - - - x (3) - - - - x - - - yes (6) - - - - - ©PENNBARRY 2014 (1) High speed only.; (2) 200 - 240, 380, 415, 460 V; (3) Nominal 1650 RPM; (4) Cls.I, Grp.D, Div. I / Cls. II, Grp.F & G, Div.I., Not available with 50 Hz.; (5) 230 V only. Not available in 200 or 208 V; (6) 230 V and 460 V only. www.PennBarry.com | Moving Your Way 9 Fumex | FX FX08 - FX13 | DIRECT DRIVE Performance Data Overview reasons, including energy savings, off hours requirements, future expansion, or unexpected field variations. Fumex direct drive models are available with single and multi-speed motors. Multi-speed motors (eg., FX16V/S/R) are designated: V (1050 RPM), S (1300 RPM), and R (1550 RPM). FX18V is an exception, being a single speed motor. Q, Q2 (1725 RPM) and Q1 (1650 RPM) are single speed motors. A single Fumex fan may be suitable for several requirements by a simple wiring change. This feature provides flexibility for a variety of Fumex direct drive models are available in six sizes (8, 10, 11, 13, 16, and 18). Capacities up to 4500 CFM, with static pressures to 1 1/2”. By using Lek-Trol™ variable speed controllers, the high speed flow rate of most models can be reduced by as much as 50%. Do not use Lek-Trol™ on medium or low speed for multi-speed models. When compared to belt drive models, direct drive fans require less maintenance, have a simpler construction, cost less, and are lighter in weight. Performances in 50 Hz applications will be less than shown below; consult your local PennBarry representative. FX08 - FX11 16 ⅞" 25" 16 ⅞" 1 ¼" 1 ¼" (FX Units Only) Galv. Steel Base = 16 Gage 24" 24" 9" x 9" WFX08 Only 14 ⅛" 25" 11 ½" x 11 ½" WFX10 WFX11 Only 25" (WFX Units Only) Aluminum Base = 0.064 (FX Units Only) Aluminum Base = 0.050 Discharge Apron = 0.050 FX08 Estimated Ship Weight = 29 lbs. FX10 Estimated Ship Weight = 32 lbs. FX11V/S/R Estimated Ship Weight = 42 lbs. FX11Q Estimated Ship Weight = 44 lbs. 18 ½" x 18 ½" Nominal HP Max Watts RPM Tip Speed FPM CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones FX08S 1/50 44 1300 3361 247 1.3 150 2.0 94 3.2 54 4.3 - - - - - - - - FX08R 1/30 55 1550 4007 288 2.4 205 2.9 154 3.5 112 4.4 72 5.2 - - - - - - FX10S 1/25 85 1300 3361 400 3.5 309 3.8 246 4.1 194 4.6 152 5.0 109 5.5 57 6.1 - - FX10R 1/12(1) 122 1550 4007 570 6.2 500 6.6 440 6.8 385 6.8 325 6.8 251 6.9 170 7.1 - - FX11V 1/25 103 1050 3058 406 1.9 225 2.2 151 3.6 119 4.2 87 4.8 57 5.5 - - - - FX11S 1/11 142 1300 3786 534 3.9 414 4.2 337 5.1 273 5.9 223 6.2 177 6.5 129 6.9 - - FX11R 1/6(2) 199 1550 4514 760 7.6 667 7.4 586 7.6 512 7.9 434 8.9 359 9.6 283 9.6 118 9.7 FX11Q 1/5 255 1725 5024 1034 10.7 959 10.5 883 10.5 804 10.5 722 10.6 631 10.9 538 10.7 313 9.7 Model 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP (1) TE motor is 1/6 Hp. (2) TE motor is 1/7 Hp. See additional notes on page 11. FX13 17 ⅞" 25 ½" 1 ¼" (FX Units Only) Galv. Steel Base = 16 Gage 24" 16 ½" 25 ½" (WFX Units Only) Aluminum Base = 0.064 (FX Units Only) Aluminum Base = 0.050 Discharge Apron = 0.050 11 ½" x 11 ½" FX13S/R Estimated Ship Weight = 45 lbs. FX13Q Estimated Ship Weight = 52 lbs. 18 ½" x 18 ½" Nominal Model FX13V 1/20 113 1050 3221 640 4.2 469 2.8 317 2.4 250 3.1 197 3.8 149 4.5 106 5.2 - - - FX13S 1/12 148 1300 3988 845 7.4 735 6.4 612 5.2 492 5.0 404 5.3 334 5.7 270 6.1 136 7.0 - - FX13R 1/6 188 1550 4755 1057 10.5 980 10.1 908 9.6 825 8.6 733 8.1 646 8.1 561 8.2 376 8.2 144 8.5 FX13Q 1/4 343 1725 5292 1261 13.6 1198 13.0 1143 12.6 1093 12.1 1033 11.7 973 11.2 909 10.8 757 10.1 515 9.6 See notes on page 11. 10 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 HP Tip 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.250” SP Speed Max RPM FPM Watts CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones Fumex | FX FX16 - FX18 | DIRECT DRIVE FX16 30 ¾" 24 ¼" 1 ¼" (FX Units Only) Galv. Steel Base = 16 Gage Aluminum Base = 0.064 24" 22 ⅜" Discharge Apron = 0.064 30 ¾" 16" x 16" FX16Q Estimated Ship Weight = 71 lbs. 20 ½" x 20 ½" Nominal Model Tip 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP Speed RPM FPM CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones HP Max Watts FX16V 1/6 485 1050 3788 1604 7.9 1358 6.5 1128 5.5 951 5.8 801 6.3 705 6.9 644 7.7 522 9.2 384 9.3 230 FX16S 1/3 527 1300 4690 1874 10.7 1693 9.5 1514 8.6 1326 8.0 1158 7.6 1023 7.7 913 8.2 735 9.6 572 9.7 379 9.9 FX16R 1/3(1) 590 1550 5592 2140 12.8 1994 11.9 1849 11.0 1709 10.2 1561 9.9 1410 9.6 1269 9.4 1033 9.7 812 11.1 583 10.8 FX16Q1 1/2 715 1650 5953 2531 15.2 2432 14.7 2332 14.2 2232 13.7 2114 13.1 1992 12.5 1868 11.9 1582 11.0 1320 11.5 1001 12.1 FX16Q2 3/4 890 1725 6223 2822 17.1 2753 16.8 2684 16.5 2594 16.1 2501 15.7 2418 15.4 2331 15.1 2119 14.2 1872 14.1 1566 14.2 9.7 (1) TE motor is 1/2 Hp. See additional notes at bottom of page. FX18 32 ½" 39" 1 ¼" (FX Units Only) Galv. Steel Base = 16 Gage Aluminum Base = 0.064 29 ½" 31" Discharge Apron = 0.080 20" x 20" 39" FX18V Estimated Ship Weight = 87 lbs. 28 ½" x 28 ½" Nominal Model FX18V HP Max Watts 3/4 969 Tip 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP Speed RPM FPM CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones 1075 6029 4489 21.0 4333 21.0 4177 20.0 4011 19.1 3831 18.1 3652 17.6 3455 17.2 3023 16.5 2431 17.5 1447 20.0 Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the air stream. ©PENNBARRY 2014 Fumex fans are only one component of a total system. As such, fan performance is directly affected by the system. It is critical that system designers determine the actual system loss to ensure that the actual flow is specified in the system design. www.PennBarry.com | Moving Your Way 11 Fumex | FX DIRECT DRIVE PERFORMANCE DATA The fan curves illustrated here show the range of capacities available for direct drive units. Each graph shows the performance of several models at one particular nominal speed. Fan curves provide a quick method for selecting a fan unit based on design point requirements. The direct drive performance charts on the previous pages provides the tabular data (CFM and static pressure) used to plot the fan curves. In addition, the horsepower tip speed and sones are tabulated. Since sound is normally an important factor in the selection of a fan, an engineer will usually want to select the “slowest” unit which meets CFM and SP requirements. Please refer to the Motor Availability section to make sure the motor you select meets your electrical requirements. Nominal 1075 RPM 1.800 STATIC PRESSURE - Inches W.G. Fan Curves 1.600 1.400 FX 18 1.200 R 1.000 0.800 0.600 0.400 0.200 0.000 0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 AIRFLOW - CFM Nominal 1550 RPM 2.250 1.750 2.000 1.500 1.250 1.000 0.750 R 11 R 250 13V 250 500 R 0 0.500 0.250 FX 500 750 1000 1250 1500 1750 0.000 2000 0 750 AIRFLOW - CFM 2.000 1.500 1.250 FX Q 16 2 (N al in om 50 M RP 0.500 16 S Q 11 13 0.750 13Q 0.500 1 S 1.000 Q 16 1.250 16 FX 0.750 0.250 S S 500 750 1000 1250 AIRFLOW - CFM 1500 1750 2000 0.000 0 400 800 1200 1600 2000 2400 2800 3200 AIRFLOW - CFM Fumex fans are only one component of a total system. As such, fan performance is directly affected by the system. It is critical that system designers determine the actual system loss to ensure that the actual flow is specified in the system design. Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances in the air stream. 12 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 S 11 FX 10 08 FX FX 250 2000 2250 1.500 FX 1.000 0 1750 1.750 FX STATIC PRESSURE - Inches W.G. 1.750 FX STATIC PRESSURE - Inches W.G. 2.250 0.000 1500 Nominal 1725 RPM 2.000 0.250 1000 1250 AIRFLOW - CFM Nominal 1300 RPM FX R 0.750 10 11 V 16 08 0.000 FX FX FX 0.250 V 1.000 R 16 1.250 13 FX 1.500 FX 0.500 1.750 FX STATIC PRESSURE - Inches W.G. 2.000 FX STATIC PRESSURE - Inches W.G. Nominal 1050 RPM Fumex | FX BELT DRIVE PERFORMANCE DATA Performance Data Belt Drive Losses The belt drive models shown on the following pages have sizes and capacities ranging from below 250 CFM to above 30,000 CFM, with static pressures from 0” to 4”. All models are available with a wide range of horsepower sizes and RPM’s. Two-speed motors are commonly used to enhance this flexibility. The AMCA Review Committee has developed the chart shown below for the purpose of estimating belt drive losses. To calculate total BHP (including drive losses): Find the BHP of your operating point on the x-axis on the graph below. Follow the vertical line to the curves indicating the range of drive losses. Look at the y-axis on the left and find the drive loss percentage. Calculate the total BHP by adding the drive loss to the operating point BHP. For BHP’s below 0.3, use 30%. • Elevation Drawing Showing Overall Dimensions • Fan Curve Graph • Performance Chart Each curve graphically displays the range of capacities available for each model, in most cases beyond the specifics shown in the tabular data. The maximum performance afforded by each horsepower is indicated by dashed lines and the RPM is indicated by solid lines. Some models have graphs that show both shaded and unshaded areas. Selection should be made from the unshaded area only. Shaded areas reflect unstable performance (“surge”), a characteristic typical of backward inclined wheels, and should be avoided. These unstable regions are not shown in the tabular data. The highest RPM shown for a specific horsepower in the tabular data is the maximum speed that for any point along the performance curve, the BHP will not exceed the available horsepower. It is important to note that while it is common industry-wide practice to exceed a “nominal” horsepower by using a motor’s service factor, PennBarry uses a conservative portion of the service factor, allowing half to remain a true “safety” factor. Drive Loss Reference Chart 30 DRIVE LOSS (% MOTOR POWER OUTPUT) The data provided for each belt drive model includes: 20 15 10 8 6 4 3 2 1.5 1 0.3 0.4 0.6 0.8 1 2 3 4 6 8 10 MOTOR POWER OUTPUT (BHP) 20 Range drive loss for standard belts. Higher fan speeds tend to have higher drive losses than lower fan speeds at the same horsepower. For totally enclosed, explosion proof, multi-speed and all 1.0 Service Factor motors, fan BHP plus drive losses should not exceed motor rated HP. Graph reprinted from AMCA publication 203, with the express written permission from the Air Movement and Control Association, Inc., 30 West University Drive, Arlington Heights, IL 60004-1983. Use the Motor Availability chart (see Motor Selection) to select motor enclosures and voltages which can be installed in the fans. ©PENNBARRY 2014 Note: Fumex fans are only one component of a total system. As such, performance is directly affected by the system. It is critical that system designers determine actual system losses to ensure that the actual flow is specified in the system range. www.PennBarry.com | Moving Your Way 13 Fumex | FX STATIC PRESSURE - Inches W.G. FX08B | BELT DRIVE 30" 35" 2.400 1975 RPM 5 ¾" 5 ¾" 2.000 27 ¼" 1719 RPM 1.600 28 ¾" 495 RPM 1.200 1374 RPM 0.800 3/ 4 0.400 0.000 16" x 16" 35" 1/4 0 200 400 600 1/3 HP 1/ HP 800 AIRFLOW - CFM 2 H P 24 ¾" x 24 ¾" HP 1000 1200 Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 55 Peak BHP = (RPM/2126)3 Max. RPM = 2085 (1 HP) Est. Ship Weight = 96 lbs.* * Add 8 lbs. for Heat & Smoke option. Tip 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 0.875” SP 1.000” SP 1.125” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1191 525 1787 700 2382 875 2978 1050 3574 1225 4169 1374 4676 1410 4799 1440 4901 1470 5003 1495 5088 1535 5224 1565 5326 1595 5428 1/2 1630 5548 1665 5667 1695 5769 1719 5850 1755 5973 1795 6109 1830 6228 1860 6330 1890 6432 1920 6535 1950 6637 1975 6722 1/4 1/3 3/4 208 1.7 0.01 312 4.2 0.01 416 4.5 0.03 520 5.9 0.06 624 8.0 0.11 728 10.6 0.17 817 12.1 0.25 838 12.6 0.27 856 13.0 0.28 874 13.4 0.30 889 13.8 0.32 912 14.3 0.34 930 14.6 0.36 948 14.9 0.39 969 15.4 0.41 990 15.8 0.44 1008 16.2 0.46 1022 16.6 0.48 1043 17.1 0.51 1067 17.7 0.55 1088 18.3 0.58 1106 18.8 0.61 1124 19.4 0.64 1141 19.8 0.67 1159 20.0 0.70 1174 21.0 0.73 162 4.2 0.01 320 4.4 0.03 447 5.8 0.07 563 7.9 0.11 677 10.4 0.18 771 11.9 0.25 793 12.3 0.27 812 12.7 0.29 831 13.2 0.31 846 13.5 0.32 871 14.0 0.35 890 14.4 0.37 909 14.0 0.39 930 15.1 0.42 952 16.7 0.44 970 17.1 0.47 985 16.4 0.49 1007 16.9 0.52 1032 17.5 0.56 1053 18.1 0.59 1072 18.6 0.62 1090 19.1 0.65 1109 19.6 0.68 1127 20.0 0.71 1142 20.0 0.74 163 4.2 0.03 359 5.6 0.07 497 7.6 0.12 623 10.2 0.18 724 11.6 0.25 748 12.1 0.27 767 12.5 0.29 787 12.9 0.21 804 13.3 0.33 830 13.8 0.35 849 14.1 0.37 869 14.5 0.40 891 14.9 0.42 914 15.3 0.45 933 15.7 0.47 948 16.1 0.49 971 16.7 0.52 997 17.3 0.56 1019 17.8 0.59 1038 18.4 0.62 1057 18.9 0.65 1076 19.4 0.68 1095 19.8 0.72 1110 20.0 0.74 231 5.3 0.07 422 7.3 0.12 564 9.8 0.18 674 11.3 0.26 700 11.8 0.27 722 12.2 0.29 743 12.6 0.31 760 13.0 0.33 787 13.5 0.35 807 13.8 0.37 828 14.2 0.40 851 14.6 0.42 875 15.1 0.45 895 15.5 0.48 911 15.9 0.50 934 16.4 0.53 961 17.0 0.56 984 17.6 0.60 1003 18.1 0.63 1023 18.6 0.66 1042 19.1 0.69 1062 19.6 0.72 1078 20.0 0.75 324 6.9 0.12 498 9.4 0.19 619 11.0 0.26 647 11.4 0.28 670 11.8 0.30 693 12.3 0.32 711 12.7 0.33 741 13.2 0.36 763 13.5 0.38 785 13.9 0.40 810 14.3 0.42 835 14.8 0.45 856 15.2 0.48 872 15.6 0.50 897 16.2 0.53 924 16.8 0.56 948 17.4 0.60 968 17.9 0.63 988 18.4 0.66 1008 18.9 0.69 1028 19.3 0.72 1045 19.7 0.75 108 6.0 0.10 421 9.0 0.19 560 10.7 0.27 591 11.1 0.29 616 11.5 0.30 640 11.9 0.32 660 12.3 0.34 692 12.9 0.37 715 13.2 0.39 738 13.5 0.41 764 14.0 0.43 790 14.5 0.46 813 14.9 0.48 830 15.2 0.50 857 15.8 0.53 886 16.5 0.57 911 17.1 0.60 933 17.6 0.63 953 18.1 0.66 974 18.6 0.69 995 19.1 0.72 1012 19.5 0.75 306 8.3 0.18 493 10.3 0.26 528 10.8 0.29 557 11.2 0.31 584 11.6 0.33 605 11.9 0.34 639 12.5 0.37 664 12.8 0.39 689 13.2 0.41 717 13.6 0.44 745 14.1 0.47 768 14.6 0.49 787 14.9 0.51 814 15.5 0.54 844 16.2 0.58 870 16.8 0.61 893 17.3 0.64 915 17.8 0.67 937 18.3 0.70 959 18.8 0.73 977 19.1 0.76 407 9.9 0.26 455 10.4 0.28 489 10.9 0.30 519 11.3 0.32 543 11.6 0.34 582 12.1 0.37 611 12.5 0.39 637 12.9 0.42 667 13.3 0.44 696 13.8 0.47 721 14.2 0.50 741 14.6 0.52 770 15.2 0.55 802 15.8 0.58 829 16.5 0.62 853 17.0 0.65 875 17.5 0.68 898 18.0 0.71 920 18.5 0.74 939 18.8 0.77 275 9.2 0.24 346 9.9 0.27 394 10.4 0.29 437 11.0 0.31 472 11.4 0.33 518 11.8 0.37 548 12.1 0.39 578 12.5 0.41 612 13.0 0.44 646 13.5 0.48 672 13.9 0.50 693 14.3 0.52 723 14.8 0.55 757 15.5 0.59 786 16.2 0.62 810 16.7 0.66 834 17.2 0.68 858 17.7 0.72 882 18.2 0.75 901 18.6 0.78 152 9.0 0.23 252 9.7 0.27 318 10.3 0.30 366 10.9 0.32 429 11.5 0.35 472 11.9 0.38 511 12.3 0.41 551 12.7 0.44 587 13.1 0.47 616 13.6 0.50 640 13.9 0.52 674 14.5 0.56 711 15.2 0.59 741 15.9 0.63 766 16.4 0.66 791 17.0 0.69 816 17.4 0.72 841 17.9 0.75 861 18.3 0.78 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 14 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 350 Fumex | FX 30" 35" 5 ¾" RPM BHP 1815 RPM 5 ¾" Do not select in shaded area. 27 ¼" 1578 RPM 28 ¾" 1372 RPM 16" x 16" 35" 1260 RPM 1600 AIRFLOW - CFM 2000 HP 1200 4 800 24 ¾" x 24 ¾" 3/ 400 HP 0 HP 2 1/ 4 HP 1/ 3 2.200 2.000 1.800 1.600 1.400 1.200 1.000 0.800 0.600 0.400 0.200 0.000 1/ STATIC PRESSURE - Inches W.G. FX10B | BELT DRIVE 2400 Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 56 Peak BHP = (RPM/1869)3 Max. RPM = 2085 (1 ½ HP) Est. Ship Weight = 96 lbs.* * Add 8 lbs. for Heat & Smoke option. Tip 0.000” SP 0.125” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.125” SP 1.250” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1/4 1/3 1/2 ©PENNBARRY 2014 3/4 600 2042 750 2553 900 3063 1000 3403 1100 3744 1260 4288 1300 4424 1325 4509 1350 4595 1372 4669 1390 4731 1420 4833 1450 4935 1475 5020 1500 5105 1525 5190 1550 5275 1578 5371 1600 5445 1630 5548 1660 5650 1695 5769 1730 5888 1765 6007 1790 6092 1815 6177 714 5.9 0.02 892 6.7 0.05 1071 7.3 0.08 1190 8.6 0.11 1309 10.4 0.14 1499 13.5 0.22 1547 13.9 0.24 1577 14.2 0.25 1607 14.4 0.27 1633 14.7 0.28 1654 15.0 0.29 1690 15.4 0.31 1726 15.9 0.33 1755 16.3 0.35 1785 16.7 0.36 1815 17.0 0.38 1845 17.2 0.40 1878 17.4 0.42 1904 17.6 0.44 1940 17.8 0.47 1976 18.0 0.49 2017 18.4 0.53 2059 18.8 0.56 2101 19.3 0.59 2130 19.8 0.62 2160 20.0 0.65 543 5.7 0.03 765 6.6 0.05 968 7.1 0.09 1097 8.4 0.12 1225 10.2 0.15 1426 13.2 0.23 1476 13.6 0.25 1507 13.9 0.26 1538 14.2 0.28 1565 14.5 0.29 1587 14.7 0.30 1624 15.2 0.32 1662 15.7 0.34 1692 16.1 0.36 1723 16.5 0.38 1754 16.8 0.40 1785 17.0 0.42 1819 17.2 0.44 1846 17.4 0.46 1883 17.6 0.48 1920 17.9 0.51 1962 18.2 0.54 2005 18.6 0.58 2048 19.2 0.61 2078 19.6 0.64 2109 20.0 0.66 596 6.5 0.06 854 7.1 0.09 998 8.3 0.13 1136 10.0 0.16 1352 13.0 0.24 1404 13.4 0.26 1437 13.7 0.28 1469 13.9 0.29 1497 14.2 0.31 1521 14.5 0.32 1559 14.9 0.34 1597 15.4 0.36 1629 15.9 0.38 1661 16.3 0.39 1693 16.6 0.41 1725 16.8 0.43 1760 17.0 0.46 1788 17.2 0.47 1826 17.4 0.50 1864 17.7 0.53 1908 18.1 0.56 1952 18.5 0.59 1995 19.0 0.63 2027 19.5 0.66 2058 20.0 0.68 696 7.1 0.10 874 8.3 0.13 1042 9.9 0.17 1271 12.7 0.25 1327 13.1 0.27 1361 13.4 0.29 1396 13.7 0.30 1426 13.9 0.32 1450 14.2 0.33 1491 14.6 0.35 1531 15.1 0.37 1565 15.6 0.39 1599 16.0 0.41 1632 16.3 0.43 1665 16.5 0.45 1701 16.8 0.47 1730 16.9 0.49 1769 17.2 0.52 1808 17.5 0.54 1853 17.9 0.58 1898 18.3 0.61 1943 18.9 0.65 1975 19.4 0.67 2007 19.9 0.70 730 8.4 0.13 915 9.9 0.18 1187 12.6 0.26 1249 13.0 0.28 1285 13.2 0.30 1320 13.4 0.31 1352 13.7 0.33 1377 13.9 0.34 1419 14.3 0.36 1461 14.8 0.38 1496 15.3 0.40 1531 15.7 0.42 1565 15.9 0.44 1600 16.2 0.46 1638 16.4 0.48 1668 16.6 0.50 1709 16.9 0.53 1749 17.2 0.56 1796 17.6 0.59 1843 18.0 0.63 1890 18.6 0.66 1923 19.0 0.69 1955 19.6 0.72 780 9.9 0.18 1076 12.6 0.26 1144 12.9 0.29 1187 13.1 0.30 1229 13.4 0.32 1266 13.6 0.33 1296 13.8 0.35 1345 14.1 0.37 1391 14.6 0.39 1427 15.0 0.41 1463 15.4 0.43 1498 15.6 0.45 1534 15.8 0.47 1573 16.1 0.49 1604 16.3 0.51 1646 16.6 0.54 1688 16.9 0.57 1736 17.3 0.60 1784 17.7 0.64 1832 18.3 0.68 1866 18.7 0.70 1900 19.2 0.73 961 12.6 0.26 1035 12.9 0.29 1080 13.1 0.31 1125 13.3 0.32 1164 13.5 0.34 1195 13.6 0.35 1247 13.9 0.37 1298 14.4 0.40 1340 14.8 0.42 1382 15.1 0.44 1423 15.3 0.46 1465 15.6 0.48 1509 15.8 0.51 1541 16.0 0.53 1584 16.2 0.55 1627 16.5 0.58 1676 16.9 0.62 1726 17.4 0.65 1775 18.0 0.69 1810 18.4 0.72 1844 18.9 0.75 892 13.3 0.32 943 13.5 0.34 984 13.6 0.35 1044 13.9 0.38 1100 14.3 0.40 1147 14.6 0.42 1193 14.9 0.44 1239 15.0 0.47 1284 15.1 0.49 1333 15.3 0.52 1371 15.4 0.54 1423 15.5 0.57 1474 15.8 0.60 1534 16.2 0.63 1592 16.7 0.67 1650 17.3 0.71 1692 17.7 0.74 1732 18.2 0.77 909 13.9 0.38 988 14.3 0.40 1045 14.6 0.42 1096 14.9 0.44 1143 15.0 0.47 1190 15.1 0.49 1241 15.3 0.52 1282 15.4 0.54 1336 15.5 0.57 1390 15.7 0.60 1451 16.0 0.64 1511 16.3 0.68 1571 16.8 0.72 1613 17.3 0.75 1655 17.8 0.78 968 14.9 0.44 1034 15.0 0.47 1091 15.1 0.49 1149 15.3 0.52 1191 15.4 0.54 1247 15.5 0.57 1302 15.7 0.60 1367 16.0 0.64 1430 16.3 0.68 1492 16.7 0.72 1535 17.0 0.75 1578 17.3 0.78 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 15 Fumex | FX STATIC PRESSURE - Inches W.G. FX12BH | BELT DRIVE 3.250 3.000 2.750 2.500 2.250 2.000 1.750 1.500 1.000 0.750 0.500 0.250 0.000 30" 35" 5 ¾" RPM BHP 1883 R PM 5 ¾" Do not select in shaded area. 27 ¼" 1639 R 28 ¾" PM 1511 R PM 16" x 16" 35" 1314 RPM 1142 RP M 1049 RPM 1 1/2 1/4 1/3 HP HP 0 400 HP 3/ 4 HP 1 HP 1/ 2 HP 24 ¾" x 24 ¾" 800 1200 1600 2000 2400 2800 3200 3600 4000 AIRFLOW - CFM Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 56 Peak BHP = (RPM/1632)3 Max. RPM = 2440 (1 HP) Est. Ship Weight = 109 lbs.* * Add 8 lbs. for Heat & Smoke option. Tip 0.250” SP 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP 2.500” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 3491 880 3657 920 3824 970 4031 1049 4360 1105 4592 1142 4746 1175 4883 1200 4987 1/2 1235 5133 1280 5320 1314 5461 1340 5569 1375 5715 1400 5818 1435 5964 1462 6076 1511 6280 1540 6400 1586 6592 1600 6650 1639 6812 1675 6961 1750 7273 1825 7585 1883 7826 1/4 1/3 3/4 1 1 1/2 1320 7.4 0.13 1416 8.4 0.14 1509 9.0 0.16 1624 9.2 0.19 1801 10.1 0.23 1924 10.8 0.27 2004 11.1 0.29 2075 11.5 0.32 2128 11.8 0.34 2203 12.1 0.37 2298 12.4 0.40 2369 12.6 0.43 2423 12.8 0.46 2496 13.1 0.49 2547 13.2 0.52 2620 13.5 0.56 2675 13.9 0.59 2775 14.7 0.65 2835 15.0 0.68 2928 15.5 0.74 2957 15.7 0.76 3036 16.2 0.81 3109 16.7 0.87 3261 18.0 0.98 3412 19.4 1.11 3529 21.0 1.22 794 7.0 0.13 1005 7.7 0.16 1140 8.4 0.18 1299 8.8 0.21 1518 9.8 0.26 1661 10.6 0.29 1754 10.9 0.32 1836 11.2 0.35 1897 11.6 0.37 1981 12.1 0.40 2085 12.7 0.44 2164 13.1 0.47 2224 13.4 0.50 2304 13.8 0.53 2360 14.1 0.56 2439 14.5 0.60 2500 14.9 0.63 2609 15.7 0.69 2672 15.9 0.73 2772 16.3 0.79 2802 16.4 0.81 2886 16.8 0.87 2963 17.3 0.92 3123 18.4 1.04 3282 19.7 1.17 3402 21.0 1.28 500 9.1 0.16 1105 10.0 0.26 1325 10.6 0.31 1445 11.0 0.34 1551 11.2 0.37 1626 11.4 0.39 1725 11.8 0.42 1846 12.4 0.46 1934 12.9 0.50 2000 13.3 0.53 2089 13.8 0.57 2151 14.1 0.59 2238 14.6 0.64 2305 15.0 0.67 2422 16.0 0.73 2490 16.3 0.77 2597 16.7 0.83 2629 16.9 0.85 2719 17.3 0.91 2801 17.8 0.97 2971 18.8 1.09 3139 19.9 1.22 3266 21.0 1.33 425 10.9 0.22 776 11.3 0.29 1028 11.7 0.35 1212 12.0 0.39 1382 12.4 0.43 1543 12.7 0.48 1654 13.1 0.52 1738 13.4 0.55 1847 13.8 0.59 1918 14.2 0.62 2017 14.7 0.66 2090 15.1 0.69 2217 16.0 0.76 2291 16.3 0.80 2408 16.8 0.87 2443 16.9 0.89 2540 17.3 0.95 2629 17.8 1.01 2809 18.8 1.14 2984 19.9 1.27 3117 21.0 1.38 470 12.5 0.31 896 13.1 0.42 1151 13.6 0.49 1343 14.1 0.54 1522 14.6 0.59 1622 14.7 0.63 1738 13.4 0.55 1826 15.5 0.71 1984 16.2 0.78 2073 16.5 0.82 2204 16.9 0.89 2243 17.1 0.92 2349 17.5 0.98 2442 17.9 1.04 2633 18.8 1.17 2821 19.8 1.31 2965 21.0 1.43 374 14.0 0.36 737 14.6 0.48 963 15.0 0.54 1228 15.7 0.63 1428 16.2 0.69 1686 17.0 0.79 1799 17.2 0.83 1950 17.4 0.91 1996 17.6 0.93 2121 17.9 1.00 2236 18.2 1.06 2449 18.8 1.20 2650 19.8 1.34 2798 21.0 1.46 564 16.1 0.51 1029 17.0 0.68 1253 17.6 0.76 1593 18.4 0.89 1675 18.6 0.93 1850 18.9 1.00 1981 19.0 1.07 2226 19.5 1.22 2461 20.0 1.37 2625 21.0 1.49 835 18.3 0.73 964 18.5 0.78 1285 19.1 0.91 1552 19.7 1.02 1969 21.0 1.22 2231 21.0 1.38 2419 21.0 1.51 817 19.6 0.84 1448 21.0 1.13 1955 22.0 1.38 2193 22.0 1.53 701 21.0 0.89 1381 22.0 1.24 1812 23.0 1.47 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 16 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 840 Fumex | FX 30" 35" 1.600 1623 RPM RPM BHP 1.400 1.200 5 ¾" 5 ¾" Do not select in shaded area. 1414 RPM 27 ¼" 28 ¾" 1.000 1230 RPM 0.800 16" x 16" 35" 1130 RPM 0.600 400 800 1200 1600 3 2000 AIRFLOW - CFM H P 24 ¾" x 24 ¾" HP 0 1/ P 0.000 HP H 4 2 1/ 0.250 4 3/ 0.400 1/ STATIC PRESSURE - Inches W.G. FX13B | BELT DRIVE 2400 2800 3200 Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 56 Peak BHP = (RPM/1751)3 Max. RPM = 2202 (1 ½ HP) Est. Ship Weight = 110 lbs.* * Add 8 lbs. for Heat & Smoke option. Tip 0.000” SP 0.250” SP 0.375” SP 0.500” SP 0.625” SP 0.750” SP 0.875” SP 1.000” SP 1.250” SP 1.375” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1/4 1/3 1/2 ©PENNBARRY 2014 3/4 500 1800 650 2340 800 2880 978 3521 1055 3798 1130 4068 1160 4176 1185 4266 1210 4356 1230 4428 1255 4518 1280 4608 1305 4698 1330 4788 1355 4878 1375 4950 1400 5040 1414 5090 1445 5202 1470 5292 1495 5382 1525 5490 1550 5580 1575 5670 1600 5760 1623 5842 874 6.3 0.02 1137 7.0 0.04 1399 7.6 0.07 1710 11.0 0.13 1845 12.7 0.17 1976 13.5 0.20 2029 13.9 0.22 2072 14.3 0.24 2116 14.6 0.25 2151 15.0 0.26 2195 15.4 0.28 2239 15.7 0.30 2282 16.1 0.31 2326 16.3 0.33 2370 16.5 0.35 2405 16.7 0.37 2449 16.9 0.39 2473 17.1 0.40 2527 17.4 0.43 2571 17.7 0.45 2615 18.0 0.47 2667 18.5 0.50 2711 18.9 0.53 2755 19.3 0.55 2798 19.6 0.58 2839 19.9 0.60 1052 7.4 0.09 1452 10.6 0.16 1608 12.3 0.20 1755 13.1 0.24 1814 13.4 0.26 1862 13.8 0.27 1911 14.1 0.29 1950 14.4 0.30 1998 14.8 0.32 2046 15.2 0.34 2094 15.6 0.36 2142 15.8 0.38 2190 16.0 0.40 2228 16.2 0.41 2275 16.4 0.43 2302 16.6 0.45 2360 16.9 0.47 2408 17.2 0.50 2455 17.6 0.52 2511 18.0 0.55 2558 18.4 0.58 2604 18.9 0.61 2651 19.2 0.63 2694 19.4 0.66 1284 10.2 0.17 1471 12.0 0.21 1635 12.9 0.25 1699 13.2 0.27 1751 13.5 0.29 1804 13.9 0.30 1845 14.2 0.32 1895 14.6 0.34 1945 14.9 0.35 1994 15.3 0.37 2044 15.5 0.39 2093 15.7 0.41 2132 15.9 0.43 2181 16.2 0.45 2208 16.3 0.47 2269 16.6 0.49 2317 16.9 0.52 2366 17.3 0.54 2424 17.7 0.57 2472 18.1 0.60 2520 18.6 0.63 2568 18.9 0.66 2612 19.2 0.68 1026 9.7 0.17 1281 11.5 0.22 1485 12.4 0.26 1559 12.8 0.28 1619 13.1 0.30 1679 13.5 0.32 1727 13.8 0.33 1782 14.2 0.35 1835 14.6 0.37 1889 15.0 0.39 1942 15.2 0.41 1995 15.4 0.43 2037 15.6 0.45 2089 15.9 0.47 2118 16.0 0.48 2180 16.4 0.51 2230 16.7 0.54 2280 17.0 0.56 2339 17.4 0.59 2388 17.8 0.62 2437 18.3 0.65 2486 18.6 0.68 2531 18.9 0.70 928 10.9 0.21 1281 11.7 0.27 1377 12.2 0.29 1448 12.5 0.31 1519 12.9 0.32 1574 13.3 0.34 1639 13.6 0.36 1701 14.0 0.38 1762 14.4 0.40 1823 14.7 0.42 1883 15.0 0.44 1931 15.3 0.46 1985 15.5 0.49 2015 15.7 0.50 2082 16.0 0.53 2135 16.3 0.55 2188 16.7 0.58 2251 17.1 0.61 2304 17.6 0.64 2356 18.0 0.67 2406 18.3 0.70 2452 18.6 0.73 1054 11.6 0.28 1196 11.9 0.30 1303 12.3 0.33 1378 12.6 0.34 1458 13.0 0.37 1535 13.4 0.39 1606 13.8 0.41 1676 14.1 0.43 1746 14.4 0.45 1796 14.7 0.47 1858 15.0 0.50 1892 15.2 0.51 1968 15.6 0.54 2028 15.9 0.57 2088 16.3 0.60 2156 16.8 0.63 2210 17.3 0.66 2264 17.7 0.69 2317 18.0 0.72 2366 18.3 0.74 1152 12.5 0.35 1292 12.9 0.38 1401 13.2 0.41 1493 13.5 0.44 1573 13.7 0.46 1636 14.0 0.48 1708 14.3 0.50 1747 14.5 0.52 1834 15.0 0.55 1903 15.3 0.58 1965 15.7 0.60 2039 16.2 0.64 2100 16.7 0.67 2160 17.3 0.70 2220 17.6 0.73 2275 18.0 0.76 1130 13.2 0.41 1314 13.4 0.45 1413 13.6 0.48 1516 13.8 0.51 1568 13.9 0.52 1671 14.3 0.56 1749 14.6 0.59 1821 15.1 0.61 1906 15.6 0.65 1975 16.1 0.68 2043 16.7 0.71 2105 17.0 0.74 2161 17.3 0.77 1341 14.4 0.59 1521 14.7 0.65 1637 15.0 0.69 1731 15.3 0.72 1818 15.6 0.76 1892 16.0 0.79 1455 15.3 0.70 1597 15.5 0.75 1707 15.7 0.79 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 17 Fumex | FX STATIC PRESSURE - Inches W.G. FX13BHFT | BELT DRIVE 3.000 2.750 2.500 2.250 2.000 1.750 1.500 1.250 1.000 0.750 0.500 0.250 0.000 35" 5 ¾" RPM BHP 1470 RPM Do not select in shaded area. 1279 RPM 28 ¾" 11 1179 RPM /2 1H 1026 RPM 3/4 892 RPM 818 RPM 0 500 1000 1/2 HP P HP HP 1/ 1/4 3 HP HP 1500 2000 2500 24 ¾" x 24 ¾" 3000 AIRFLOW - CFM 3500 4000 4500 Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 56 Peak BHP = (RPM/1277)3 Max. RPM = 1875 (1 ½ HP) Est. Ship Weight = 115 lbs.* * Add 8 lbs. for Heat & Smoke option. Tip 0.250” SP 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP 2.500” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 3670 818 4002 850 4159 892 4365 925 4526 950 4648 975 4771 1000 4893 1026 5020 1050 5138 1075 5260 1100 5382 1125 5505 1150 5627 1179 5769 1200 5872 1225 5994 1255 6141 1279 6258 1300 6361 1325 6483 1360 6655 1 1/2 1400 6850 1425 6973 1450 7095 1470 7193 1/3 1/2 3/4 1 1817 7.2 0.19 2046 7.9 0.25 2152 8.4 0.27 2289 9.3 0.31 2395 9.9 0.35 2476 10.3 0.38 2554 10.7 0.41 2630 11.3 0.44 2709 11.8 0.47 2782 12.3 0.50 2858 13.0 0.54 2933 13.6 0.57 3008 14.2 0.61 3083 14.5 0.65 3169 14.9 0.70 3232 15.2 0.74 3306 15.6 0.79 3396 16.1 0.84 3467 16.5 0.89 3529 16.9 0.93 3603 17.3 0.99 3706 17.9 1.07 3824 18.5 1.16 3897 18.9 1.22 3972 19.3 1.29 4032 19.5 1.34 1312 6.7 0.20 1645 7.4 0.26 1781 7.9 0.29 1953 8.8 0.33 2080 9.4 0.37 2176 9.8 0.40 2270 10.1 0.43 2360 10.6 0.46 2451 11.1 0.50 2534 11.6 0.53 2619 12.2 0.57 2705 12.8 0.60 2788 13.4 0.64 2871 13.7 0.68 2967 14.1 0.73 3036 14.4 0.77 3118 14.8 0.82 3216 15.2 0.88 3294 15.6 0.93 3362 16.0 0.97 3442 16.5 1.02 3554 17.1 1.10 3677 17.7 1.20 3753 18.1 1.26 3829 18.5 1.33 3889 18.7 1.38 915 7.2 0.23 1168 7.7 0.28 1463 8.4 0.33 1641 9.0 0.38 1769 9.4 0.41 1888 9.7 0.44 2006 10.1 0.48 2119 10.7 0.52 2218 11.2 0.55 2321 11.8 0.59 2421 12.5 0.63 2518 13.1 0.67 2613 13.4 0.71 2723 13.7 0.76 2802 14.0 0.80 2891 14.2 0.85 2996 14.6 0.91 3079 15.0 0.96 3151 15.3 1.00 3237 15.7 1.06 3355 16.2 1.14 3489 16.8 1.24 3572 17.2 1.30 3654 17.5 1.36 3720 17.8 1.42 782 8.3 0.30 1100 9.0 0.37 1298 9.4 0.41 1483 9.8 0.46 1666 10.3 0.51 1798 10.8 0.55 1932 11.3 0.59 2057 12.0 0.63 2177 12.6 0.68 2294 12.9 0.73 2422 13.3 0.78 2510 13.6 0.82 2613 13.9 0.87 2736 14.3 0.93 2830 14.6 0.98 2911 14.9 1.03 3007 15.3 1.09 3139 15.9 1.17 3288 16.5 1.27 3375 16.8 1.34 3462 17.2 1.40 3532 17.4 1.46 739 9.4 0.39 1104 10.1 0.48 1333 10.8 0.54 1529 11.3 0.60 1708 12.0 0.66 1881 12.4 0.72 2038 12.9 0.78 2150 13.2 0.82 2277 13.5 0.88 2420 13.9 0.95 2533 14.3 1.0 2631 14.6 1.06 2737 15.0 1.11 2882 15.5 1.20 3046 16.1 1.29 3145 16.5 1.36 3241 16.8 1.43 3318 17.1 1.49 828 11.1 0.51 1206 11.6 0.63 1471 12.2 0.72 1636 12.6 0.78 1819 13.1 0.85 2029 13.6 0.93 2165 14.0 0.99 2278 14.4 1.04 2411 14.8 1.11 2581 15.3 1.20 2770 15.9 1.32 2887 16.2 1.39 2992 16.5 1.46 3075 16.8 1.51 611 12.0 0.54 1054 12.5 0.70 1442 13.1 0.84 1633 13.6 0.92 1797 14.0 0.99 1978 14.5 1.07 2222 15.1 1.18 2438 15.7 1.30 2571 16.1 1.37 2697 16.4 1.45 2793 16.7 1.52 569 13.3 0.63 972 13.6 0.79 1351 14.1 0.95 1688 14.8 1.10 1997 15.5 1.25 2174 15.9 1.34 2349 16.3 1.43 2463 16.6 1.50 680 14.8 0.79 1355 15.4 1.10 1651 15.8 1.24 1849 16.2 1.34 2006 16.5 1.43 493 16.1 0.80 1028 16.2 1.08 1345 16.5 1.24 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 18 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 750 1/4 Fumex | FX 1.800 5 ¾" Do not select in shaded area. 1355 RPM 1.400 5 ¾" RPM BHP 1467 RPM 1.600 27 ¼" 28 ¾" 1.200 1179 RPM 1.000 16" x 16" 35" 1026 RPM 943 RPM 0.800 0.600 0.400 1/4 500 1000 1500 2000 1/ 3 HP 2500 1/ 2 H P 3/ 4 H P 24 ¾" x 24 ¾" 3000 3500 AIRFLOW - CFM P 0 HP H 0.200 0.000 30" 35" 2.000 1 STATIC PRESSURE - Inches W.G. FX14B | BELT DRIVE 4000 4500 Galv. Steel Base = 16 Gage Aluminum Base = 0.064 Discharge Apron = 0.064 Roof/Wall Opening = 16” SQ. Damper Size = 15 ¾” SQ. Max. Motor Frame Size = 56 Peak BHP = (RPM/1462)3 Max. RPM = 2085 (1 ½ HP) Est. Ship Weight = 112 lbs.* * Add 11 lbs. for Heat & Smoke option. Tip 0.000” SP 0.250” SP 0.500” SP 0.625” SP 0.750” SP 0.875” SP 1.000” SP 1.250” SP 1.375” SP 1.500” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 400 1662 550 2286 690 2868 815 3387 880 3657 943 3919 975 4052 1/3 1000 4156 1026 4264 1050 4364 1075 4468 1100 4572 1130 4696 1160 4821 1179 4900 1210 5029 1240 5154 1270 5278 1300 5403 1330 5528 1355 5631 1385 5756 1405 5839 1430 5943 1450 6026 1467 6097 1/4 1/2 3/4 ©PENNBARRY 2014 1 1061 4.8 0.02 1459 4.9 0.04 1830 7.8 0.09 2162 10.2 0.14 2334 11.8 0.18 2502 13.0 0.22 2586 13.6 0.25 2653 14.0 0.26 2722 14.3 0.29 2785 14.7 0.31 2852 15.2 0.33 2918 15.8 0.35 2998 16.6 0.38 3077 17.4 0.41 3128 18.1 0.43 3210 19.1 0.47 3290 19.4 0.50 3369 19.4 0.54 3449 19.6 0.58 3528 19.9 0.62 3595 20.0 0.66 3674 21.0 0.70 3727 21.0 0.73 3794 22.0 0.77 3847 22.0 0.81 3892 23.0 0.83 1283 6.9 0.10 1743 9.3 0.17 1955 11.1 0.21 2154 12.3 0.26 2253 12.8 0.28 2330 13.3 0.30 2410 13.7 0.32 2483 14.1 0.35 2559 14.5 0.37 2634 15.0 0.39 2724 15.9 0.43 2812 16.7 0.46 2867 17.4 0.48 2956 18.4 0.52 3043 18.7 0.55 3129 18.7 0.59 3214 18.9 0.63 3300 19.2 0.68 3371 19.6 0.72 3456 20.0 0.76 3512 20.0 0.79 3583 21.0 0.84 3639 22.0 0.87 3687 22.0 0.90 673 8.0 0.14 1367 9.8 0.21 1673 11.0 0.27 1812 11.5 0.30 1914 12.0 0.32 2019 12.5 0.35 2110 13.0 0.37 2198 13.4 0.39 2285 13.8 0.42 2388 14.6 0.45 2490 15.6 0.49 2553 16.2 0.51 2654 17.2 0.55 2750 17.5 0.59 2846 17.6 0.63 2941 17.9 0.67 3035 18.3 0.72 3113 18.6 0.76 3206 19.2 0.80 3268 19.6 0.84 3344 20.0 0.88 3405 21.0 0.91 3457 21.0 0.94 1230 10.4 0.25 1480 11.0 0.29 1615 11.5 0.32 1738 12.0 0.35 1850 12.4 0.37 1963 12.9 0.40 2067 13.3 0.43 2189 14.0 0.46 2309 14.9 0.50 2377 15.6 0.52 2485 16.6 0.56 2590 16.8 0.60 2693 17.0 0.64 2795 17.3 0.69 2893 17.7 0.73 2974 18.0 0.77 3070 18.6 0.82 3134 19.0 0.85 3214 19.7 0.90 3277 20.0 0.93 3331 21.0 0.97 887 10.8 0.27 1267 11.4 0.32 1504 12.1 0.36 1659 12.6 0.39 1791 13.0 0.43 1933 13.5 0.46 2072 14.4 0.50 2157 15.0 0.52 2284 16.1 0.57 2406 16.3 0.61 2526 16.5 0.65 2634 16.8 0.70 2738 17.1 0.74 2825 17.5 0.78 2928 18.0 0.83 2997 18.5 0.87 3081 19.1 0.91 3147 19.6 0.95 3202 20.0 0.98 838 12.2 0.32 1269 12.6 0.39 1593 13.3 0.44 1786 14.2 0.49 1889 14.9 0.52 2038 15.9 0.57 2178 16.0 0.61 2315 16.0 0.65 2439 16.2 0.70 2561 16.6 0.75 2662 17.0 0.79 2777 17.5 0.85 2848 17.9 0.88 2935 18.5 0.93 3005 19.0 0.96 3063 19.5 0.99 657 13.2 0.33 1147 13.9 0.44 1394 14.7 0.49 1718 15.8 0.54 1909 15.9 0.60 2067 15.8 0.65 2209 15.9 0.70 2349 16.2 0.75 2464 16.5 0.79 2588 17.0 0.85 2670 17.4 0.89 2771 18.0 0.93 2852 18.5 0.97 2919 19.0 1.01 812 15.8 0.48 1324 15.8 0.62 1698 15.9 0.71 1938 16.1 0.76 2126 16.3 0.83 2235 16.6 0.88 2359 17.0 0.93 2454 17.4 0.97 2533 17.8 1.01 829 15.9 0.55 1241 16.1 0.67 1665 16.3 0.79 1893 16.6 0.79 2093 16.9 0.90 2216 17.1 0.96 2309 17.4 1.00 817 16.3 0.61 1054 16.6 0.70 1529 16.9 0.84 1780 17.1 0.91 1972 17.4 0.96 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 19 Fumex | FX 1389 RPM 2.250 2.000 RPM BHP 1.500 6 ½" 6 ½" Do not select in shaded area. 1261 RPM 1.750 29 ½" 31" 1098 RPM 1.250 1013 RPM 1.000 39" 20" x 20" 881 RPM 0.750 767 RPM 705 RPM 4800 HP HP 4000 28 ½" x 28 ½" 2 3200 2 2400 AIRFLOW - CFM 1/ 1600 HP 800 P 0 1/ 1/ 2 HP HP 3 HP H 4 1 1/ 0.250 1 0.500 0.000 32 ½" 39" 2.500 4 3/ STATIC PRESSURE - Inches W.G. FX16B | BELT DRIVE 5600 Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ. Peak BHP = (RPM/1095)3 Aluminum Base = 0.080 Damper Size = 19 ¾” SQ. Max. RPM = 1755 (3 HP) Discharge Apron = 0.064 Max. Motor Frame Size = 145T Est. Ship Weight = 144 lbs.* * Add 11 lbs. for Heat & Smoke option. Tip 0.000” SP 0.250” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.250” SP 1.375” SP 1.500” SP 1.750” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1/4 1/3 1/2 3/4 1 1 1/2 2446 609 2979 660 3229 705 3449 725 3547 745 3645 767 3752 800 3914 830 4061 855 4183 881 4310 920 4501 955 4672 985 4819 1013 4956 1045 5112 1070 5235 1098 5372 1140 5577 1180 5773 1220 5969 1261 6169 1295 6335 1330 6507 1365 6678 1389 6795 1999 6.0 0.08 2435 8.8 0.15 2639 9.7 0.19 2819 10.7 0.23 2899 11.1 0.25 2979 11.6 0.27 3067 12.0 0.30 3199 12.6 0.34 3319 13.2 0.38 3419 13.7 0.41 3523 14.3 0.45 3679 15.3 0.51 3819 16.3 0.57 3939 17.0 0.63 4051 17.5 0.68 4179 18.2 0.75 4279 18.7 0.81 4391 19.4 0.87 4559 21.0 0.97 4719 22.0 1.08 4879 23.0 1.19 5043 24.0 1.32 5179 25.0 1.43 5318 26.0 1.55 5458 26.0 1.67 5554 27.0 1.76 1280 5.2 0.09 1951 8.1 0.17 2213 9.2 0.21 2426 10.1 0.26 2518 10.6 0.28 2611 11.1 0.30 2712 11.5 0.33 2862 11.9 0.37 2997 12.4 0.41 3106 12.9 0.45 3219 13.5 0.49 3387 14.4 0.55 3536 15.5 0.61 3664 16.1 0.67 3783 16.6 0.72 3918 17.2 0.79 4023 17.8 0.84 4141 18.5 0.91 4317 19.9 1.01 4484 21.0 1.12 4652 22.0 1.23 4823 23.0 1.36 4965 24.0 1.47 5111 25.0 1.59 5256 25.0 1.72 5355 26.0 1.81 1791 8.1 0.26 1971 8.6 0.29 2111 9.2 0.32 2247 9.8 0.34 2434 10.5 0.39 2596 11.2 0.43 2727 11.7 0.47 2862 12.3 0.51 3062 13.3 0.57 3233 14.4 0.64 3374 15.0 0.70 3505 15.6 0.76 3653 16.2 0.83 3768 16.8 0.89 3896 17.7 0.96 4087 19.1 1.07 4267 20.0 1.18 4440 22.0 1.29 4617 22.0 1.42 4764 23.0 1.53 4913 24.0 1.65 5063 25.0 1.78 5165 25.0 1.87 1770 8.6 0.33 2109 9.4 0.39 2342 10.2 0.44 2497 10.9 0.48 2645 11.6 0.52 2860 12.6 0.58 3044 13.7 0.65 3200 14.4 0.71 3344 15.0 0.77 3506 15.7 0.84 3626 16.3 0.90 3757 17.2 0.97 3953 18.6 1.08 4138 20.0 1.19 4321 21.0 1.31 4508 22.0 1.44 4661 23.0 1.56 4817 23.0 1.68 4969 24.0 1.81 5073 25.0 1.90 1791 9.2 0.41 2109 9.8 0.46 2352 10.6 0.52 2635 11.9 0.60 2841 13.0 0.66 3010 13.8 0.72 3160 14.4 0.78 3329 15.1 0.85 3459 15.7 0.91 3603 16.6 0.98 3817 18.1 1.09 4009 19.4 1.20 4196 21.0 1.33 4387 21.0 1.46 4544 22.0 1.57 4704 23.0 1.70 4864 24.0 1.83 4972 24.0 1.93 2011 11.1 0.61 2412 11.8 0.71 2678 12.7 0.79 2930 13.7 0.87 3092 14.4 0.94 3253 15.3 1.00 3491 16.9 1.11 3704 18.3 1.23 3913 19.5 1.35 4125 20.0 1.48 4299 21.0 1.60 4475 22.0 1.73 4641 23.0 1.86 4753 23.0 1.96 2287 12.8 0.86 2662 13.4 0.98 3060 15.0 1.13 3352 16.8 1.26 3594 18.1 1.38 3827 19.2 1.51 4012 20.0 1.63 4197 21.0 1.76 4380 22.0 1.89 4505 22.0 1.99 2656 14.1 1.08 3069 15.7 1.24 3397 17.3 1.39 3663 18.4 1.53 3858 19.3 1.65 4055 20.0 1.77 4244 21.0 1.90 4371 22.0 2.00 2634 14.9 1.18 3093 16.2 1.36 3453 17.5 1.53 3687 18.5 1.66 3900 19.5 1.79 4100 21.0 1.92 4235 21.0 2.02 2609 16.4 1.39 3102 17.0 1.60 3452 17.7 1.77 3751 18.8 1.94 3920 19.7 2.05 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 20 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 2 500 Fumex | FX 2.250 1268 RPM 2.000 1.500 6 ½" 6 ½" RPM BHP Do not select in shaded area. 1151 RPM 1.750 29 ½" 31" 1002 RPM 1.250 39" 20" x 20" 924 RPM 1.000 804 RPM 0.750 700 RPM 643 RPM 1600 2400 3200 1/ 2 HP 1 3/ 4 4000 AIRFLOW - CFM HP HP 4800 5600 28 ½" x 28 ½" HP 800 P HP 0 1/ HP 3 H 2 1/4 0.250 2 1/ 0.500 0.000 32 ½" 39" 2.500 1 STATIC PRESSURE - Inches W.G. FX18B | BELT DRIVE 6400 Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ. Peak BHP = (RPM/999)3 Aluminum Base = 0.080 Damper Size = 19 ¾” SQ. Max. RPM = 1403 (2 HP) Discharge Apron = 0.064 Max. Motor Frame Size = 145T Est. Ship Weight = 145 lbs.* * Add 20 lbs. for Heat & Smoke option. Tip 0.000” SP 0.250” SP 0.500” SP 0.625” SP 0.750” SP 1.000” SP 1.250” SP 1.375” SP 1.500” SP 1.750” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1/4 1/3 1/2 3/4 1 ©PENNBARRY 2014 1 1/2 2 400 2121 556 2948 600 3181 643 3409 665 3525 685 3631 700 3711 730 3870 760 4029 785 4162 804 4262 840 4453 870 4612 900 4771 924 4899 950 5036 975 5169 1002 5312 1040 5513 1080 5726 1120 5938 1151 6102 1190 6309 1215 6441 1245 6600 1268 6722 1984 4.7 0.05 2758 8.9 0.15 2976 10.0 0.18 3189 11.1 0.23 3299 11.6 0.25 3398 12.0 0.27 3472 12.3 0.29 3621 13.2 0.33 3770 14.2 0.37 3894 15.1 0.41 3988 15.9 0.44 4167 16.7 0.50 4316 17.2 0.56 4464 17.6 0.62 4584 18.3 0.67 4712 19.2 0.73 4837 20.0 0.79 4970 21.0 0.85 5159 22.0 0.95 5357 22.0 1.07 5556 23.0 1.19 5710 24.0 1.29 5903 24.0 1.43 6027 25.0 1.52 6176 26.0 1.64 6290 26.0 1.73 2050 7.9 0.17 2345 9.0 0.21 2618 10.3 0.26 2755 10.8 0.28 2873 11.2 0.31 2961 11.7 0.33 3136 12.6 0.37 3309 13.7 0.42 3452 14.7 0.46 3559 15.5 0.49 3759 16.3 0.56 3922 16.8 0.61 4084 17.3 0.68 4212 17.8 0.73 4351 18.7 0.79 4485 19.6 0.85 4628 20.0 0.92 4829 21.0 1.02 5039 22.0 1.14 5249 23.0 1.26 5411 23.0 1.37 5614 24.0 1.51 5744 25.0 1.60 5899 25.0 1.72 6019 26.0 1.81 1885 9.8 0.28 2147 10.4 0.32 2279 10.7 0.35 2503 11.7 0.39 2716 12.8 0.44 2890 13.9 0.48 3021 14.8 0.52 3261 15.6 0.59 3454 16.1 0.65 3643 16.6 0.71 3794 17.1 0.76 3952 18.0 0.83 4100 18.9 0.89 4258 19.9 0.96 4479 21.0 1.07 4709 21.0 1.20 4937 22.0 1.33 5113 23.0 1.44 5327 24.0 1.58 5463 24.0 1.67 5625 25.0 1.79 5749 25.0 1.89 2328 12.3 0.44 2569 13.4 0.49 2710 14.3 0.52 2968 15.1 0.59 3179 15.6 0.66 3385 16.2 0.72 3548 16.6 0.78 3716 17.4 0.84 3876 18.3 0.91 4047 19.4 0.98 4285 20.0 1.09 4525 21.0 1.21 4759 22.0 1.35 4940 22.0 1.46 5165 23.0 1.60 5308 24.0 1.70 5479 25.0 1.83 5610 25.0 1.92 2640 14.6 0.59 2891 15.1 0.66 3108 15.7 0.73 3279 16.1 0.79 3461 16.9 0.86 3634 17.8 0.92 3818 18.9 1.00 4067 19.7 1.11 4322 20.0 1.23 4574 21.0 1.36 4767 22.0 1.47 4997 23.0 1.62 5144 23.0 1.72 5319 24.0 1.84 5453 25.0 1.94 2805 15.7 0.84 3093 16.7 0.93 3319 17.7 1.01 3595 18.5 1.13 3878 19.3 1.26 4156 20.0 1.40 4368 21.0 1.51 4626 22.0 1.66 4786 22.0 1.76 4977 23.0 1.89 5123 24.0 1.99 3357 18.3 1.26 3709 18.9 1.42 3935 19.5 1.53 4213 21.0 1.69 4388 21.0 1.79 4597 22.0 1.92 4755 23.0 2.03 3364 18.7 1.39 3696 19.2 1.53 4002 20.0 1.70 4183 21.0 1.80 4397 22.0 1.93 4558 22.0 2.04 3752 19.8 1.69 3970 20.0 1.81 4195 21.0 1.94 4362 22.0 2.05 3541 21.0 1.87 3850 21.0 2.03 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 21 Fumex | FX 39" 4.000 3.500 1606 RPM Do not select in shaded area. 3.000 29 ½" 2.500 1401 RPM 2.000 1270 RPM 1.500 1105 RPM 1019 RPM 1.000 886 RPM 770 RPM 0 31" 1 1/ 2 HP 1/2 1 3 HP 1/3 HP /4 H HP P 1000 2000 3000 4000 5000 AIRFLOW - CFM 2 HP 6000 39" 20" x 20" 28 ½" x 28 ½" HP 0.500 0.000 32 ½" 6 ½" 6 ½" RPM BHP 3 STATIC PRESSURE - Inches W.G. FX18BH | BELT DRIVE 7000 8000 Galv. Steel Base = 14 Gage Roof/Wall Opening = 20” SQ. Peak BHP = (RPM/1106)3 Aluminum Base = 0.080 Damper Size = 19 ¾” SQ. Max. RPM = 1870 (3 HP) Discharge Apron = 0.064 Max. Motor Frame Size = 145T Wall Mounted Max. HP = 2 Est. Ship Weight = 142 lbs. (Add 20 lbs. for Heat & Smoke option.) Tip 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP 2.500” SP 3.000” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 1/3 1/2 3/4 1 1 1/2 2 3 4082 800 4241 840 4453 886 4697 915 4851 970 5142 1019 5402 1065 5646 1080 5726 1105 5858 1125 5964 1150 6097 1175 6229 1200 6362 1225 6494 1270 6733 1280 6786 1335 7077 1375 7289 1401 7427 1440 7634 1480 7846 1520 8058 1560 8270 1585 8403 1606 8514 2308 7.6 0.33 2520 7.9 0.37 2773 8.4 0.42 3028 9.4 0.48 3186 10.1 0.53 3475 11.5 0.62 3712 12.4 0.71 3932 13.0 0.81 4003 13.2 0.84 4121 13.5 0.90 4216 13.9 0.94 4333 14.2 1.00 4450 14.7 1.07 4570 15.3 1.13 4697 16.1 1.18 4925 17.0 1.29 4975 17.1 1.32 5251 18.4 1.46 5449 19.4 1.57 5578 20.0 1.64 5770 21.0 1.76 5958 22.0 1.89 6139 24.0 2.03 6321 25.0 2.19 6434 26.0 2.28 6528 27.0 2.37 1622 8.1 0.36 2108 8.9 0.44 2436 9.4 0.52 2628 9.9 0.57 3017 10.7 0.66 3342 11.3 0.75 3598 11.9 0.85 3681 12.2 0.88 3818 12.6 0.93 3926 12.9 0.98 4061 13.4 1.04 4193 14.0 1.11 4315 14.5 1.17 4436 15.2 1.24 4652 16.2 1.38 4700 16.3 1.41 4961 17.2 1.58 5150 18.2 1.72 5272 18.8 1.82 5454 19.8 1.96 5650 21.0 2.11 5853 22.0 2.24 6055 24.0 2.39 6181 25.0 2.48 6286 25.0 2.56 1676 10.0 0.52 2435 11.5 0.68 2786 12.0 0.79 3093 12.4 0.89 3200 12.5 0.93 3378 12.7 0.98 3519 12.8 1.03 3693 13.0 1.09 3850 13.3 1.15 3990 13.6 1.22 4129 14.3 1.29 4376 15.3 1.42 4430 15.5 1.45 4728 16.6 1.63 4931 17.6 1.77 5057 18.2 1.86 5245 19.3 2.01 5436 20.0 2.17 5627 22.0 2.34 5816 23.0 2.52 5934 24.0 2.64 6032 24.0 2.74 1779 12.1 0.71 2515 13.3 0.88 2675 13.6 0.93 2884 13.7 1.00 3019 13.9 1.06 3186 14.1 1.13 3352 14.3 1.20 3525 14.6 1.28 3703 14.9 1.34 4019 15.3 1.47 4089 15.4 1.50 4424 16.1 1.68 4646 17.1 1.82 4789 17.8 1.91 5002 18.8 2.06 5218 20.0 2.22 5428 21.0 2.39 5623 23.0 2.57 5744 24.0 2.69 5845 24.0 2.79 1361 13.4 0.73 2151 14.1 0.98 2575 14.8 1.10 2844 15.5 1.19 3088 15.7 1.29 3258 16.0 1.37 3559 16.5 1.52 3625 16.6 1.56 4008 17.1 1.74 4290 17.5 1.88 4471 17.9 1.97 4720 18.7 2.12 4944 19.7 2.28 5165 21.0 2.45 5385 23.0 2.63 5520 23.0 2.75 5634 24.0 2.85 1920 15.5 1.11 2544 16.4 1.3 3081 17.7 1.51 3188 17.9 1.55 3599 18.4 1.77 3865 18.8 1.93 4036 19.1 2.04 4315 19.6 2.19 4598 20.0 2.35 4876 21.0 2.51 5124 22.0 2.69 5264 23.0 2.81 5381 24.0 2.91 1895 17.3 1.28 3051 19.2 1.73 3478 20.0 1.93 3670 20.0 2.05 3933 21.0 2.22 4198 21.0 2.41 4474 22.0 2.59 4759 23.0 2.77 4935 23.0 2.88 5081 24.0 2.98 2571 19.9 1.78 3073 21.0 1.98 3494 22.0 2.20 3852 23.0 2.41 4122 23.0 2.61 4389 24.0 2.82 4553 24.0 2.96 4700 25.0 3.06 2481 22.0 1.98 3274 23.0 2.34 3705 25.0 2.59 4060 25.0 2.83 4230 26.0 2.96 4371 26.0 3.08 1714 24.0 1.93 2907 26.0 2.71 3378 27.0 2.95 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 22 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 770 Fumex | FX STATIC PRESSURE - Inches W.G. FX24B | BELT DRIVE 46" 3.500 1237 RPM 3.000 36" 7" RPM BHP 7" Do not select in shaded area. 35 ⅞" 2.500 1042 RPM 2.000 1.500 825 RPM 3 710 RPM 662 RPM 576 RPM 501 RPM 1.000 0.500 0.000 5 909 RPM 0 1 1/3 2000 3/4 1 HP 1/2 HP HP HP 4000 1/ 2 2 HP 34 ½" H P 25" x 25" 46" H P HP 6000 33 ½" x 33 ½" 8000 AIRFLOW - CFM 10000 12000 Galv. Steel Base = 14 Gage Roof/Wall Opening = 25” SQ. Peak BHP = (RPM/716)3 Aluminum Base = 0.080 Damper Size = 24 ¾” SQ. Max. RPM = 1360 (5 HP) Discharge Apron = 0.064 Max. Motor Frame Size = 184T Wall Mounted Max. HP = 2 Est. Ship Weight = 190 lbs. (Add 40 lbs. for Heat & Smoke option.) Tip 0.250” SP 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP 2.500” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 375 2436 420 2728 461 2995 480 3118 501 3255 540 3508 576 3742 610 3963 640 4157 662 4300 690 4482 718 4664 755 4905 1 1/2 790 5132 825 5359 850 5522 880 5717 909 5905 950 6171 985 6399 1015 6593 1042 6769 1100 7146 1150 7470 1200 7795 1237 8036 1/4 1/3 1/2 3/4 1 2 ©PENNBARRY 2014 3 5 1986 5.9 0.14 2701 7.3 0.20 3245 8.7 0.27 3471 9.5 0.30 3717 10.4 0.34 4163 11.9 0.42 4543 12.9 0.51 4896 14.0 0.60 5203 14.9 0.69 5421 15.5 0.76 5697 16.2 0.85 5972 16.9 0.95 6332 18.2 1.10 6670 19.7 1.25 7007 21.0 1.42 7246 21.0 1.55 7532 22.0 1.71 7808 23.0 1.88 8197 25.0 2.14 8527 28.0 2.37 8809 29.0 2.59 9062 29.0 2.80 9605 30.0 3.28 10071 32.0 3.74 10536 34.0 4.23 10879 36.0 4.63 2992 10.7 0.42 3557 11.7 0.52 4036 12.9 0.62 4433 14.0 0.72 4709 14.7 0.79 5040 15.4 0.89 5367 16.2 1.00 5791 17.4 1.16 6167 19.0 1.32 6534 19.9 1.49 6793 20.0 1.62 7103 21.0 1.79 7397 23.0 1.97 7803 25.0 2.23 8148 27.0 2.47 8441 28.0 2.69 8705 29.0 2.90 9267 30.0 3.39 9749 31.0 3.85 10228 33.0 4.35 10581 35.0 4.75 3236 12.8 0.67 3676 13.6 0.77 4126 14.3 0.89 4542 15.1 1.01 5049 16.4 1.18 5510 18.1 1.35 5937 19.0 1.53 6231 19.5 1.67 6580 20.0 1.84 6913 22.0 2.03 7367 24.0 2.30 7736 26.0 2.55 8050 27.0 2.78 8330 28.0 2.99 8927 29.0 3.50 9424 30.0 3.96 9916 33.0 4.47 10279 35.0 4.87 3116 13.9 0.88 4070 15.3 1.12 4663 16.9 1.33 5185 18.0 1.53 5538 18.5 1.68 5939 19.3 1.87 6321 21.0 2.06 6824 23.0 2.34 7236 25.0 2.60 7585 26.0 2.83 7896 27.0 3.05 8539 28.0 3.57 9065 29.0 4.05 9586 32.0 4.57 9968 34.0 4.99 4151 16.8 1.43 4660 17.5 1.61 5165 18.3 1.83 5599 19.6 2.04 6187 22.0 2.35 6655 24.0 2.62 7050 25.0 2.86 7390 26.0 3.09 8076 27.0 3.62 8656 28.0 4.11 9227 31.0 4.65 9623 33.0 5.07 3845 17.3 1.63 4660 18.4 1.92 5435 21.0 2.29 5973 23.0 2.59 6417 24.0 2.86 6795 25.0 3.10 7568 26.0 3.65 8197 27.0 4.16 8788 30.0 4.70 9219 32.0 5.13 4130 19.3 2.05 5102 22.0 2.45 5681 23.0 2.77 6123 24.0 3.04 6985 25.0 3.64 7669 26.0 4.17 8330 29.0 4.73 8793 31.0 5.18 4389 22.0 2.49 5217 23.0 2.87 6327 24.0 3.56 7085 25.0 4.13 7804 28.0 4.73 8300 30.0 5.18 5393 23.0 3.35 6427 25.0 4.02 7221 27.0 4.67 7770 29.0 5.16 5428 24.0 3.77 6552 26.0 4.53 7190 28.0 5.08 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 23 Fumex | FX STATIC PRESSURE - Inches W.G. FX24BH | BELT DRIVE 46" 4.500 1429 RPM 4.000 3.500 7" Do not select in shaded area. 1203 RPM 3.000 2.500 5 1049 RPM 2.000 3 951 RPM 1.500 0.500 0 35 ⅞" HP 34 ½" 2000 4000 25" x 25" 46" HP 2H P 11 /2 HP 1H P 3/4 1/2 HP HP 828 RPM 763 RPM 663 RPM 1.000 0.000 36" 7" RPM BHP 33 ½" x 33 ½" 6000 AIRFLOW - CFM 8000 10000 Galv. Steel Base = 14 Gage Roof Opening = 25” SQ. Peak BHP = (RPM/827)3 Aluminum Base = 0.080 Damper Size = 24 ¾” SQ. Max. RPM = 1620 (5 HP) Discharge Apron = 0.064 Max. Motor Frame Size = 184T Wall Mounted Max. HP = 2 Est. Ship Weight = 187 lbs. (Add 40 lbs. for Heat & Smoke option.) Tip 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP 2.500” SP 3.000” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 3897 663 4306 707 4592 725 4709 763 4956 800 5196 828 5378 855 5553 886 5755 1 1/2 915 5943 925 6008 951 6177 990 6430 1019 6619 1049 6814 1080 7015 1105 7177 1125 7307 1175 7632 1203 7814 1210 7859 1245 8087 1275 8281 1325 8606 1380 8963 1429 9282 3/4 1 2 3 5 2641 8.9 0.38 3231 10.0 0.51 3633 10.8 0.61 3774 11.1 0.65 4069 11.9 0.75 4351 12.4 0.86 4549 12.7 0.94 4736 13.1 1.03 4950 13.7 1.13 5148 14.7 1.23 5216 15.2 1.27 5393 16.0 1.37 5657 16.9 1.53 5856 17.4 1.66 6063 18.0 1.80 6276 18.8 1.95 6447 19.5 2.08 6583 20.0 2.19 6923 22.0 2.48 7122 23.0 2.65 7160 23.0 2.69 7395 24.0 2.92 7597 24.0 3.12 7931 25.0 3.49 8298 27.0 3.92 8623 29.0 4.33 2472 10.3 0.51 2971 11.0 0.63 3142 11.3 0.67 3497 12.0 0.78 3844 12.5 0.89 4107 12.8 0.98 4357 13.1 1.07 4607 13.7 1.19 4833 14.6 1.30 4910 15.0 1.34 5110 15.7 1.45 5403 16.5 1.62 5605 16.9 1.75 5813 17.4 1.89 6027 18.0 2.05 6198 18.6 2.18 6335 19.3 2.29 6675 21.0 2.58 6864 22.0 2.76 6911 22.0 2.80 7152 23.0 3.03 7359 23.0 3.24 7702 24.0 3.61 8078 26.0 4.04 8411 28.0 4.46 1877 10.8 0.56 2264 11.4 0.64 2824 12.3 0.78 3259 12.6 0.91 3542 12.9 1.00 3796 13.3 1.10 4083 13.7 1.22 4355 14.6 1.34 4450 15.0 1.38 4695 15.7 1.49 5056 16.5 1.67 5288 16.9 1.81 5522 17.4 1.96 5761 18.0 2.13 5953 18.6 2.32 6105 19.1 2.39 6461 21.0 2.69 6655 21.0 2.86 6704 21.0 2.91 6945 22.0 3.14 7151 23.0 3.35 7492 24.0 3.73 7865 25.0 4.17 8198 27.0 4.59 2352 12.7 0.85 2822 13.4 0.98 3180 13.6 1.09 3546 14.0 1.23 3857 14.6 1.35 3953 14.9 1.40 4198 15.6 1.51 4560 16.5 1.70 4831 16.9 1.85 5115 17.4 2.00 5405 18.0 2.18 5635 18.6 2.32 5801 19.1 2.44 6191 21.0 2.75 6407 21.0 2.94 6461 21.0 2.99 6728 22.0 3.24 6954 23.0 3.47 7302 23.0 3.84 7683 25.0 4.29 8019 26.0 4.72 1929 13.3 0.93 2740 14.3 1.17 3223 14.9 1.33 3345 15.0 1.38 3655 15.5 1.51 4107 16.5 1.72 4384 17.0 1.87 4667 17.5 2.03 4954 18.1 2.21 5184 18.6 2.36 5375 19.1 2.48 5846 21.0 2.80 6105 21.0 3.00 6169 21.0 3.05 6453 22.0 3.30 6688 23.0 3.53 7074 23.0 3.93 7493 25.0 4.41 7843 26.0 4.84 2152 14.8 1.20 2859 15.8 1.43 3503 16.7 1.69 3851 17.2 1.85 4203 17.8 2.04 4539 18.4 2.23 4777 18.9 2.38 4965 19.3 2.51 5429 20.0 2.84 5690 21.0 3.04 5757 21.0 3.09 6088 22.0 3.35 6368 22.0 3.58 6815 23.0 3.99 7246 25.0 4.47 7624 26.0 4.93 2353 16.5 1.48 3096 17.5 1.76 3597 18.3 1.99 4005 18.8 2.20 4301 19.3 2.73 4535 19.7 2.51 5047 21.0 2.86 5311 21.0 3.07 5377 21.0 3.12 5701 22.0 3.39 5977 23.0 3.63 6453 23.0 4.04 6965 25.0 4.53 7384 26.0 4.99 2447 17.9 1.75 3270 19.1 2.10 2689 19.9 2.31 4002 20.0 2.48 4597 21.0 2.85 4924 22.0 3.08 5004 22.0 3.14 5341 22.0 3.41 5624 23.0 3.65 6088 24.0 4.08 6604 25.0 4.58 7065 26.0 5.05 2546 19.4 2.03 3184 20.0 2.32 4058 22.0 2.80 4425 22.0 3.04 4508 22.0 3.10 4922 23.0 3.40 5270 23.0 3.67 5750 24.0 4.10 6264 25.0 4.62 6717 26.0 5.05 2767 22.0 2.65 3740 24.0 3.21 4244 25.0 3.54 4933 26.0 4.07 5580 26.0 4.64 6086 27.0 5.16 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 24 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 600 1/2 Fumex | FX STATIC PRESSURE - Inches W.G. FX27B | BELT DRIVE 3.000 53 ½" 1091 RPM RPM BHP 2.500 Do not select in shaded area. 921 RPM 2.000 1.500 804 RPM 1.000 638 RPM 580 RPM 507 RPM 442 RPM 5 3 731 RPM 0.500 0.000 6 ½" 0 2 11 1H /2 3/4 P HP 1/ 1/3 2 HP HP 2000 4000 H P 35 ½" HP HP HP 36 ½" x 36 ½" 6000 8000 AIRFLOW - CFM 10000 Galv. Steel Base = 14 Gage Roof Opening = 28” SQ. Peak BHP = (RPM/539)3 Aluminum Base = 0.080 Damper Size = 27 ¾” SQ. Max. RPM = 1188 (5 HP) Discharge Apron = 0.080 Max. Motor Frame Size = 184T Est. Ship Weight = 219 lbs.* 12000 * Add 55 lbs. for Heat & Smoke option. Tip 0.125” SP HP RPM Speed FPM Sones BHP 1/3 1/2 3/4 1 1 1/2 2 3 ©PENNBARRY 2014 5 442 3211 475 3451 507 3683 535 3887 560 4068 580 4214 600 4359 620 4504 638 4635 660 4795 685 4976 705 5122 731 5311 750 5449 770 5594 785 5703 804 5841 830 6030 865 6284 895 6502 921 6691 960 6974 1000 7265 1045 7592 1091 7926 4361 8.3 0.30 4780 9.7 0.37 5120 10.7 0.44 5444 11.7 0.51 4361 12.7 0.59 5960 13.5 0.65 6188 14.2 0.71 6415 14.9 0.78 6631 15.4 0.85 6868 15.9 0.94 7150 16.7 1.04 7374 17.4 1.13 7666 18.4 1.26 7879 19.0 1.35 8103 19.6 1.46 8270 20.0 1.54 8482 21.0 1.66 8772 22.0 1.82 9161 23.0 2.05 9493 25.0 2.26 9782 26.0 2.46 10213 28.0 2.78 10655 30.0 3.14 11151 31.0 3.57 11658 34.0 4.05 0.250” SP Sones BHP 3843 7.7 0.33 4293 9.0 0.40 4710 10.1 0.48 5065 11.1 0.55 4361 12.2 0.63 5628 13.1 0.69 5870 13.8 0.76 6107 14.6 0.83 6330 15.0 0.90 6577 15.7 0.99 6869 16.4 1.10 7101 17.1 1.19 7403 18.1 1.32 7622 18.7 1.42 7853 19.3 1.53 8025 19.8 1.62 8243 20.0 1.73 8540 21.0 1.89 8938 23.0 2.13 9278 24.0 2.35 9573 26.0 2.55 10013 27.0 2.87 10463 29.0 3.23 10967 31.0 3.66 11482 33.0 4.15 0.375” SP Sones BHP 3112 7.1 0.33 3695 8.6 0.41 4213 9.8 0.50 4617 10.7 0.58 4361 11.7 0.66 5234 12.7 0.73 5498 13.4 0.80 5756 14.2 0.87 5990 14.6 0.94 6264 15.2 1.04 6578 16.0 1.15 6827 16.7 1.24 7144 17.7 1.38 7369 18.4 1.48 7605 18.9 1.59 7782 19.4 1.68 8004 19.9 1.80 8308 21.0 1.97 8716 22.0 2.21 9063 24.0 2.43 9364 25.0 2.63 9812 27.0 2.96 10270 29.0 3.32 10783 31.0 3.76 11305 33.0 4.25 0.500” SP Sones BHP 2634 7.6 0.38 3530 9.2 0.49 4030 10.3 0.59 4361 11.5 0.67 4785 12.5 0.75 5076 13.2 0.82 5363 13.8 0.90 5625 14.3 0.98 5913 14.8 1.07 6248 15.6 1.19 6506 16.3 1.29 6839 17.4 1.42 7080 18.0 1.53 7332 18.5 1.64 7521 18.9 1.73 7758 19.5 1.85 8080 22.0 2.00 8497 22.0 2.27 8851 23.0 2.50 9156 25.0 2.71 9612 26.0 3.04 10078 28.0 3.41 10599 30.0 3.85 11129 33.0 4.35 0.750” SP Sones BHP 3159 10.9 0.69 3889 12.0 0.80 4304 12.9 0.90 4635 13.5 0.99 5018 14.2 1.10 5461 15.0 1.24 5782 15.7 1.34 6161 16.7 1.49 6434 17.4 1.60 6719 17.9 1.72 6925 18.3 1.82 7183 18.8 1.94 7534 19.6 2.12 7988 21.0 2.38 8372 22.0 2.61 8702 24.0 2.82 9193 25.0 3.17 9691 27.0 3.55 10236 29.0 4.01 10780 31.0 4.53 1.000” SP Sones BHP 4209 13.8 1.17 4753 14.7 1.31 5247 15.8 1.48 5583 16.6 1.61 5932 17.3 1.76 6200 17.8 1.86 6528 18.4 2.00 6910 18.9 2.18 7415 20.0 2.46 7840 22.0 2.70 8195 23.0 2.93 8720 25.0 3.28 9239 26.0 3.67 9814 28.0 4.14 10395 31.0 4.66 1.250” SP Sones BHP 4127 15.0 1.49 4856 16.0 1.67 5250 16.6 1.81 5628 17.3 1.97 6092 18.1 2.18 6706 19.7 2.49 7239 21.0 2.75 7624 23.0 2.99 8189 24.0 3.36 8757 26.0 3.77 9369 28.0 4.26 9981 30.0 4.80 1.500” SP Sones BHP 4830 16.9 2.05 5853 18.6 2.43 6421 20.0 2.73 6881 22.0 2.99 7568 24.0 3.40 8221 25.0 3.83 8875 27.0 4.34 9531 29.0 4.91 2.000” SP Sones BHP 5162 18.4 2.56 6055 20.0 2.90 6816 22.0 3.36 7523 24.0 3.83 8318 26.0 4.39 9039 29.0 4.96 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 25 Fumex | FX STATIC PRESSURE - Inches W.G. FX30B | BELT DRIVE 2.750 2.500 2.250 2.000 1.750 1.500 1.250 1.000 0.750 0.500 0.250 0.000 53 ½" 931 RPM 6 ½" RPM BHP Do not select in shaded area. 5 784 RPM 684 RPM 3 621 RPM 11 541 RPM 498 RPM 1 3/4 HP 1/2 HP H 1/3 P HP 434 RPM 377 RPM 0 2000 4000 /2 2H HP 35 ½" HP P HP 36 ½" x 36 ½" 6000 8000 10000 12000 14000 16000 AIRFLOW - CFM Galv. Steel Base = 14 Gage Roof Opening = 28” SQ. Peak BHP = (RPM/539)3 Aluminum Base = 0.080 Damper Size = 27 ¾” SQ. Max. RPM = 1188 (5 HP) Discharge Apron = 0.080 Max. Motor Frame Size = 184T Est. Ship Weight = 219 lbs.* * Add 65 lbs. for Heat & Smoke option. Tip 0.000” SP 0.250” SP 0.500” SP 0.750” SP 1.000” SP 1.250” SP 1.500” SP 1.750” SP 2.000” SP 2.250” SP HP RPM Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 2782 377 3023 400 3207 420 3367 434 3480 455 3648 480 3848 498 3993 520 4169 541 4338 560 4490 1 1/2 595 4770 621 4979 640 5131 665 5332 684 5484 710 5693 730 5853 750 6013 770 6174 784 6286 805 6454 840 6735 880 7055 915 7336 931 7464 1/2 3/4 1 2 3 5 5314 7.6 0.22 5773 8.9 0.28 6125 10.1 0.33 6431 10.9 0.38 6646 11.6 0.42 6968 12.5 0.49 7350 13.7 0.57 7626 14.6 0.64 7963 15.6 0.73 8285 16.4 0.82 8576 17.1 0.91 9112 18.5 1.09 9510 19.7 1.24 9801 21.0 1.35 10184 22.0 1.52 10474 22.0 1.65 10873 23.0 1.85 11179 24.0 2.01 11485 25.0 2.18 11792 26.0 2.36 12006 27.0 2.49 12328 28.0 2.69 12863 30.0 3.06 13476 31.0 3.52 14012 33.0 3.96 14257 34.0 4.17 3779 7.2 0.27 4431 8.5 0.34 4899 9.5 0.40 5283 10.2 0.46 5548 10.7 0.50 5937 11.6 0.57 6377 12.8 0.66 6690 13.6 0.74 7069 14.6 0.83 7428 15.4 0.93 7748 16.1 1.02 8333 17.5 1.21 8764 18.8 1.36 9077 19.6 1.48 9488 21.0 1.79 9798 21.0 1.79 10221 22.0 1.99 10545 23.0 2.15 10869 24.0 2.33 11191 25.0 2.51 11416 26.0 2.64 11753 27.0 2.85 12313 29.0 3.22 12951 30.0 3.69 13507 32.0 4.13 13760 34.0 4.35 3742 10.0 0.51 4445 10.8 0.61 5078 11.9 0.71 5505 12.7 0.79 5984 13.8 0.90 6433 14.6 1.00 6818 15.2 1.10 7491 16.5 1.30 7983 17.8 1.46 8335 18.6 1.59 8776 19.7 1.77 9109 20.0 1.92 9560 21.0 2.13 9905 22.0 2.30 10248 23.0 2.49 10588 24.0 2.68 10824 25.0 2.81 11177 26.0 3.03 11761 28.0 3.41 12424 29.0 3.88 13000 31.0 4.33 13263 32.0 4.54 4939 13.3 1.01 5514 14.1 1.13 6397 15.4 1.35 6985 16.6 1.53 7397 17.5 1.67 7930 18.7 1.86 8314 19.4 2.01 8817 20.0 2.23 9199 21.0 2.40 9578 22.0 2.59 9953 23.0 2.78 10211 24.0 2.93 10582 25.0 3.15 11196 27.0 3.55 11889 28.0 4.04 12491 30.0 4.52 12764 31.0 4.75 5581 15.3 1.52 6193 16.2 1.68 6835 17.4 1.89 7311 18.1 2.06 7911 19.0 2.29 8347 19.9 2.48 8777 21.0 2.68 9202 22.0 2.89 9487 23.0 3.04 9895 24.0 3.26 10566 26.0 3.66 11322 27.0 4.16 11963 29.0 4.64 12245 30.0 4.87 5817 16.8 1.99 6748 17.7 2.29 7299 18.6 2.50 7806 19.4 2.71 8305 21.0 2.93 8630 21.0 3.09 9090 23.0 3.33 9844 25.0 3.76 10674 26.0 4.29 11351 28.0 4.77 11658 29.0 5.00 6405 18.2 2.63 7144 19.3 2.91 7591 20.0 3.09 8132 21.0 3.35 9011 23.0 3.81 9918 25.0 4.35 10673 27.0 4.87 11015 28.0 5.11 7982 22.0 3.79 9049 23.0 4.38 9923 25.0 4.92 10285 27.0 5.17 7955 22.0 4.32 9018 24.0 4.92 9427 25.0 5.18 7663 23.0 4.74 8352 24.0 5.11 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 26 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 347 1/3 Fumex | FX 66" 2.500 761 RPM 2.250 2.000 Do not select in shaded area. 664 RPM 1.750 5 ½" RPM BHP 47 ½" 1.500 1.250 560 RPM 1.000 488 RPM 443 RPM 0.750 4000 1 2 1/ HP 1H 2H P P 8000 12000 3 HP 44 ½" x 44 ½" 16000 AIRFLOW - CFM HP 0 3/4 HP HP 2 1/ 0.000 1/2 HP 0.250 7 386 RPM 355 RPM 309 RPM 0.500 5 STATIC PRESSURE - Inches W.G. FX36B | BELT DRIVE 20000 24000 Galv. Steel Base = 12 Gage Roof Opening = 36” SQ. Peak BHP = (RPM/384)3 Aluminum Base = 0.102 Damper Size = 35 ½” SQ. Max. RPM = 810 (7 ½ HP) Discharge Apron = 0.080 Max. Motor Frame Size = 213T Est. Ship Weight = 470 lbs.* * Add 110 lbs. for Heat & Smoke option. Tip 0.000” SP HP RPM Speed FPM Sones BHP 269 2619 309 3008 335 3261 355 3456 370 3602 386 3758 405 3943 1 1/2 420 4089 443 4313 465 4527 488 4751 500 4868 515 5014 530 5160 550 5355 560 5452 580 5647 600 5841 620 6036 640 6231 664 6464 680 6620 700 6815 7 1/2 720 7010 745 7253 761 7409 1/2 3/4 1 2 3 ©PENNBARRY 2014 5 7603 5.6 0.25 8734 7.2 0.37 9469 8.4 0.48 10034 9.4 0.57 10458 10.1 0.64 10911 10.9 0.73 11448 11.8 0.84 11872 12.6 0.94 12522 14.0 1.10 13144 15.0 1.27 13794 16.3 1.47 14133 17.3 1.58 14557 18.3 1.73 14981 18.8 1.88 15547 19.4 2.11 15829 19.8 2.22 16395 21.0 2.47 16960 22.0 2.73 17525 24.0 3.02 18091 25.0 3.32 18769 26.0 3.71 19221 27.0 3.98 19787 28.0 4.34 20352 29.0 4.72 21059 31.0 5.23 21511 32.0 5.58 0.250” SP Sones BHP 4897 5.4 0.34 6761 6.8 0.51 7715 7.8 0.63 8409 8.7 0.74 8912 9.3 0.82 9441 10.0 0.92 10054 11.0 1.04 10531 11.8 1.15 11255 13.1 1.32 11941 14.2 1.51 12653 15.5 1.72 13022 16.5 1.84 13483 17.5 2.00 13942 18.1 2.17 14552 18.7 2.42 14855 19.1 2.54 15460 20.0 2.82 16063 22.0 3.10 16663 24.0 3.41 17262 25.0 3.74 17978 26.0 4.17 18453 26.0 4.47 19047 27.0 4.86 19639 29.0 5.28 20372 31.0 5.81 20839 32.0 6.17 0.500” SP Sones BHP 6306 8.2 0.88 7253 8.8 1.01 8198 9.7 1.17 8875 10.5 1.30 9785 11.8 1.51 10593 12.8 1.71 11417 14.2 1.94 11823 15.1 2.07 12327 16.1 2.23 12827 16.6 2.41 13488 17.2 2.65 13810 17.6 2.78 14449 18.7 3.05 15084 20.0 3.34 15713 22.0 3.64 16339 24.0 3.96 17086 24.0 4.38 17581 25.0 4.67 18197 26.0 5.05 18813 27.0 5.48 19579 29.0 6.04 20067 31.0 6.42 0.750” SP Sones BHP 8429 11.7 1.76 9673 13.4 2.05 10221 14.3 2.20 10896 15.3 2.40 11516 15.7 2.60 12259 16.1 2.87 12627 16.5 3.00 13354 17.6 3.29 14062 19.0 3.60 14738 21.0 3.92 15407 22.0 4.26 16203 23.0 4.69 16726 23.0 5.00 17367 24.0 5.39 18003 25.0 5.81 18794 27.0 6.36 19297 29.0 6.73 1.000” SP Sones BHP 8139 14.3 2.29 9322 14.7 2.59 10497 15.2 2.94 11008 15.6 3.10 11922 16.7 3.44 12820 18.3 3.80 13596 20.0 4.14 14337 21.0 4.50 15213 22.0 4.96 15791 22.0 5.28 16481 23.0 5.69 17155 24.0 6.13 17990 26.0 6.70 18520 28.0 7.08 1.250” SP Sones BHP 9624 15.7 3.35 10863 17.3 3.77 12025 19.4 4.22 12945 21.0 4.63 14029 21.0 5.15 14708 22.0 5.51 15455 22.0 5.94 16193 23.0 6.39 17104 25.0 6.99 17681 27.0 7.40 1.375” SP Sones BHP 10842 18.7 4.14 12022 20.0 4.61 13246 21.0 5.17 13975 21.0 5.54 14874 22.0 6.03 15681 23.0 6.52 16610 25.0 7.12 17198 26.0 7.53 1.500” SP Sones BHP 10872 19.7 4.53 12296 20.0 5.14 13211 21.0 5.56 14131 21.0 6.05 15037 23.0 6.57 16116 24.0 7.25 16714 26.0 7.66 1.750” SP Sones BHP 12265 20.0 5.96 13445 22.0 6.56 14756 24.0 7.31 15488 25.0 7.77 2.000” SP Sones BHP 12913 22.0 7.17 13862 24.0 7.71 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. www.PennBarry.com | Moving Your Way 27 Fumex | FX 2.000 1.800 1.600 1.200 7.5 10 7 5H RPM P 0 5000 1/ 2 48" P 1 1/2 RPM H 0.200 0.000 M RPM 250 R PM 200 RP M 0.400 4" Do not select in shaded area. 300 0.600 1 5 350 0.800 78" RPM BHP RPM RP 400 1.000 3/4 3 450 1.400 HP 2 496 10 STATIC PRESSURE - Inches W.G. FMX50B | BELT DRIVE HP 3H P 59" x 59" 2H P 1H P 10000 15000 20000 AIRFLOW - CFM 25000 Galv. Steel Base = 12 Gage Roof/Wall Opening = 50” SQ. Peak BHP = (RPM/218)3 Aluminum Base = 0.125 Damper Size = 49 ½” SQ. Max. RPM = 496 (10 HP) Discharge Apron = 0.125 Max. Motor Frame Size = 215T Est. Ship Weight = 928 lbs. Tip 0.000 0.125 0.250 0.375 0.500 0.625 0.750 1.000 1.250 1.500 Speed FPM Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP Sones BHP 190 2487 210 2749 220 2880 230 3011 240 3142 255 3338 265 3469 280 3665 290 3796 300 3927 320 4189 330 4320 350 4581 370 4843 390 5105 400 5236 410 5367 420 5498 430 5629 440 5760 450 5890 460 6021 470 6152 480 6283 490 6414 496 6493 9590 6.8 0.58 10599 7.7 0.78 11104 8.2 0.90 11609 8.6 1.03 12114 9.0 1.17 12871 9.4 1.40 13376 9.6 1.57 14133 9.8 1.86 14637 9.8 2.06 15142 10.3 2.28 16152 11.2 2.77 16656 11.7 3.04 17666 12.6 3.62 18675 13.5 4.28 19685 14.2 5.02 20189 14.6 5.41 20694 14.9 5.83 21199 15.2 6.27 21704 15.5 6.72 22208 15.7 7.20 22713 16.0 7.70 23218 16.2 8.23 23723 16.3 8.78 24227 16.4 9.35 24732 17.0 9.95 25035 17.3 10.3 6496 6.5 0.50 7916 7.5 0.71 8594 8.0 0.82 9235 8.4 0.95 9844 8.9 1.09 10742 9.6 1.32 11332 10.0 1.48 12203 10.7 1.76 12775 11.1 1.96 13343 11.6 2.18 14466 12.8 2.66 15023 13.4 2.92 16127 14.6 3.50 17221 15.7 4.15 18307 16.9 4.88 18846 16.2 5.27 19383 16.9 5.68 19919 17.5 6.11 20454 18.2 6.57 20987 18.9 7.05 21519 19.5 7.54 22049 20.2 8.07 22579 20.8 8.61 23108 21.5 9.18 23635 22.2 9.77 23951 22.6 10.14 - - 3932 7.4 0.53 5052 7.8 0.65 6059 8.2 0.79 6952 8.6 0.94 8155 9.1 1.17 8913 9.5 1.35 10011 10.1 1.64 10713 10.5 1.84 11401 11.1 2.07 12737 12.3 2.56 13350 12.9 2.82 14558 14.2 3.39 15745 15.3 4.03 16914 16.4 4.75 17489 17.0 5.14 18060 17.6 5.55 18628 18.1 5.97 19193 18.7 6.43 19756 19.2 6.90 20316 19.7 7.39 20874 20.2 7.91 21429 20.6 8.45 21982 21.1 9.02 22534 21.8 9.60 22864 22.2 9.97 2496 8.6 0.62 4559 9.1 0.92 5705 9.4 1.11 7267 9.7 1.41 8170 9.8 1.63 9007 10.3 1.86 10577 11.5 2.35 11319 12.1 2.63 12761 13.5 3.22 14139 14.8 3.88 15481 15.9 4.62 16096 16.4 5.01 16705 17.0 5.41 17310 17.6 5.84 17910 18.2 6.29 18506 18.7 6.75 19098 19.2 7.25 19686 19.7 7.76 20271 20.1 8.30 20850 20.6 8.86 21425 21.3 9.44 21768 21.7 9.81 3318 9.7 1.03 4715 9.8 1.30 5907 10.3 1.56 8087 11.2 2.09 8998 11.7 2.37 10689 12.6 2.97 12250 13.8 3.64 13724 15.1 4.39 14446 15.7 4.79 15143 16.2 5.21 15832 16.9 5.65 16514 17.5 6.11 17189 18.0 6.59 17855 18.6 7.10 18471 19.1 7.61 19081 19.5 8.14 19688 20.0 8.70 20290 20.7 9.28 20650 21.1 9.65 4744 11.2 1.67 5981 11.7 2.01 8219 12.6 2.65 10154 13.5 3.34 11846 14.2 4.10 12643 14.6 4.50 13421 15.3 4.93 14167 15.8 5.37 14904 16.5 5.84 15632 16.6 6.33 16346 17.7 6.83 17041 18.3 7.36 17730 18.8 7.91 18412 19.2 8.49 19087 20.0 9.09 19490 20.5 9.47 5128 12.6 2.17 7529 13.5 2.96 9705 14.2 3.75 10643 14.6 4.17 11543 14.9 4.60 12393 15.2 5.05 13199 15.5 5.52 13994 15.9 6.01 14767 16.5 6.53 15513 17.1 7.06 16250 17.7 7.61 16980 18.2 8.20 17699 19.1 8.80 18119 19.6 9.17 3798 14.2 2.58 5311 14.6 3.12 6654 14.9 3.67 7864 15.2 4.20 9007 15.5 4.70 10104 15.7 5.22 11171 16.0 5.76 12119 16.2 6.31 13022 16.3 6.88 13904 16.4 7.48 14717 17.0 8.09 15199 17.3 8.46 4825 15.7 3.88 6364 16.0 4.56 7638 16.2 5.23 8842 16.3 5.90 9985 16.4 6.53 11088 17.0 7.17 11733 17.3 7.57 4992 16.4 4.93 6520 17.0 5.74 7381 17.3 6.24 Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. For further information on estimating belt drive losses and motor service factors see page 12. The sound ratings shown are for loudness values in fan sones at 5’0’ (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet hemispherical sone levels. Performance ratings do not include the effects of appurtenances in the airstream. 28 www.PennBarry.com | Moving Your Way ©PENNBARRY 2014 RPM Fumex | FX ENGINEERING SPECIFICATIONS Model FX =Centrifugal Fan WFX = Wall Mounted Centrifugal Fan FMX =High Capacity Centrifugal Fan Unit Size 08, 10 , 11, 12, 13, 14, 16, 18, 24, 27, 30, 36, 50 Drive Type D= Direct Drive B = Belt Drive Q = 1725 RPM R = 1550 RPM S = 1300 RPM V = 1050 RPM Q1 = 1650 RPM Q2 = 1725 RPM Motor Speed 1= Single Speed 2= 2S2W Single & Three Phase 3= 2S1W Three Phase 1/50 1/121/5 3/4 1/30 1/111/4 1 1/25 1/7 1/3 1 1/2 1/201/6 1/2 2 3 5 7 1/2 10 G= 230V H= 240V J = 277V K= 380V L = 400V M= 415V Phase 1 = Single 3 = Three Cycle 5= 50 Hz 6= 60 Hz Efficiency ©PENNBARRY 2014 S= Standard H= High Efficiency 0 = None S = Single D= Double Metal Liner 0 = None L = Metal Liner Damper Holding Plate 0 = None P= Damper Holding Plate 0 = None G= Gasket No Wooden Nailer 0 = None N= No Wooden Nailer Curb Paint/Coating B= Air Dried Epoxy Q= Enamel Hinged Sub-base 0 = None H= Hinged Sub-base Mounting Pedestal 0 = None P= Mounting Pedestal Floating Hinge Kit 0 = None H= Floating Hinge Kit Damper N= 440V P= 460V Q= 480V R= 575V S= 600V X= Special Slope Neoprene Gasket 0 = None C = Standard B = Optional O = Open Drip Proof T = Totally Enclosed E = Explosion Proof X = Special A = 110V B= 115V C= 120V D= 200V E= 208V F = 220V 0 = None 50= Chrome Green 53= Williamsburg Blue 55= Pale Green 56= Dove Gray 61= White 63= Oxford Beige 65= Dover White 66= Desert Tan 70= Black 73= Smoke Gray 77= Brick Red 79= Peppercorn 81= Pale Brown 83= Chocolate Brown 85= Timeless Bronze 94= Charcoal X = Special AMCA Spark Rating Enclosure Voltage 0 = None F = Epoxy Powder Coat* G= Epoxy Powder Coat with UV* H= Hi-Temp Powder Coat* J = Non-stick Powder Coat* K= Phenolic Powder Coat* L = Phenolic Powder Coat with UV* N= Polyester Powder Coat X= Special * Not available with choice of color. Color Motor Tap Horse Power Paint / Coating Aluminum Base 0 = None BDD = Gravity Back Draft Damper MD1 = Gravity Back Draft Damper 115V MD2 = Gravity Back Draft Damper 230V MD4 = Gravity Back Draft Damper 460V ED1 = Explosion Proof Motor Operated Damper 115V 0 = None P= Thermal Overload Protection Screen Disconnect Switch 0= None B= Bird Screen S= Insect/Bird Screen Roof Curb 0 = None A = UCG8 B= UCG12 C= UCG18 D= UCA8 E= UCA12 F = SFA12 G= SFA18 H= SCG16 J = SCA16 K= UCA18 L = UG12 M= SA16 N= SFG12 P= SFG18 Q= SG16 R= SRA16 S= SRG16 T = UA12 U= UA18 V = UG18 W= URA12 Y = URA18 1 = URG12 10= SFA8 11= USCG 12= USCA 2 = URG18 4 = UVA18 5 = UVG18 0 = None A = Aluminum Base Thermal Overload Protection 0 = None 1 = NEMA 1 Disconnect Switch 3R= NEMA 3R Disconnect Switch 4 = NEMA 4 Disconnect Switch 7 = NEMA 7 Disconnect Switch 9 = NEMA 9 Disconnect Switch Internal Wiring 0 = None 1 = NEMA 1 Internal Wiring 3R= NEMA 3R Internal Wiring Continued, next page. www.PennBarry.com | Moving Your Way 29 Fumex | FX ENGINEERING SPECIFICATIONS Transformer 0 = None T = Transformer Speed Controller 0 = None L = Loose M = Mounted Firestat Switch 0 = None F = Firestat Switch Fatrap 0 = None F = Fatrap Heat & Smoke Removal 0 = None -HS = Heat & Smoke Removal Wall Mount 0 = None W= Wall Mount High Pressure Wheel 0 = None H = High Pressure Wheel High Wind Construction 0 = None M = Miami Dade Approved Fumex - Direct Drive Units Direct drive centrifugal roof exhaust upblast fan shall be Fumex FX, manufactured by PennBarry, Plano, TX 75074. The housing shall be weatherproof, utilize heavy gauge spun aluminum construction with a large rolled bead for strength, with galvanized (aluminum optional) base, with rigid galvanized steel internal support structures. Housing shall not provide any of the internal structural support. Units shall be equipped with an oversized electrical conduit chase through the curb cap and into the motor compartment for ease of wiring (except Explosion Proof). Units shall be pre-wired to a junction box mounted in the motor compartment and equipped with an electrical disconnect device (except Explosion Proof). Statically and dynamically balanced backward inclined, centrifugal wheels shall be aluminum, spark-resistant, nonoverloading, and matched to deeply spun venturis. Motors shall be continuous duty, permanently lubricated, multispeed (for applicable models), have thermal overload protection, mounted out of the main airstream, be easily accessible for service, and furnished at the specified voltage, phase and enclosure. Each fan shall bear the AMCA Certified Ratings Seal for Air and Sound Performance, and shall be UL (UL Std. 705, UL Std. 762 optional applicable models) and CSA listed. If specified (Fatrap option), fan shall additionally provide UL 762 Listing rated at 400ºF, motor pre-wired to a weather-proof junction box, and drain connection leading into a grease collector/separator box. Fumex - Belt Drive Units Belt drive centrifugal roof exhaust upblast fan shall be Fumex FX/FMX, manufactured by PennBarry, Plano, TX 75074. The housing shall be weatherproof, utilize heavygauge spun aluminum construction with a large rolled bead for strength, with galvanized (aluminum optional except FMX) base, with rigid galvanized steel internal support structures. Housing shall not provide any of the internal structural support. Large diameter cooling tube shall provide ambient air to flow over motor. Units shall be equipped with an oversized electrical conduit chase through the curb cap and into the motor compartment for ease of wiring (except Explosion Proof). Units shall be prewired to a junction box mounted in the motor compartment and equipped with an electrical disconnect device (except Explosion Proof). Statically and dynamically balanced backward inclined, centrifugal wheels shall be aluminum, spark-resistant, nonoverloading, and be matched to deeply spun venturis. Motors shall be continuous duty, ball bearing design, permanently lubricated, mounted out of the main airstream, and furnished at the specified voltage, phase, and enclosure. Shafts shall be turned, ground and polished. Heavy duty ball bearings are rated for a minimum L50 life exceeding 200,000 hours. Pulleys shall be adjustable, cast iron, machined, keyed, securely attached, and sized for 150% of the horsepower at its rated maximum speed. Each fan shall bear the AMCA Certified Ratings Seal for Air and Sound Performance (FX) or for Air performance (FMX), and shall be UL (UL Std. 705, UL Std. 762 optional) and CSA listed. If specified (Fatrap option), fan shall additionally provide UL 762 Listing rated at 400ºF. (300ºF FMX), motor pre-wired to a weatherproof junction box, and drain connection leading into a grease collector/separator box. If specified (heat and smoke removal option), fan shall additionally provide UL listing rated for 500°F at 4-hours and 1000°F at 1 hour, including steel wheel and additional cooling tube. ©PENNBARRY 2014 30 www.PennBarry.com | Moving Your Way Connect with PennBarry PennBarry Product Solutions COMMERCIAL INDUSTRIAL ENERGY RECOVERY Roof & Wall Exhaust Centrifugal Fans Utility Vent Sets Outdoor Units Ceiling, Wall, & Inline Centrifugal Fans Freestanding Centrifugal Fans Indoor Units Roof Supply Centrifugal Fans Industrial & Material Handling Fans Square & Round Centrifugal Fans Tubular Centrifugal Inline Fans Wall Mounted Axial Fans Mixed Flow Centrifugal Fans Hooded Roof Axial Fans Plug & Plenum Fans Upblast Roof Axial Fans Wall Mounted Propeller Fans Gravity Ventilators Tube Axial Fans Roof Curbs Vane Axial Fans KITCHEN VENTILATION Kitchen Hoods Make-Up Air Units Exhaust Fans Bifurcator Fans Fume Exhaust Moving Your Way PennBarry is proud to be your preferred manufacturer of commercial and industrial fans and blowers. Learn how PennBarry can assist you in your next application by contacting your PennBarry Representative or visiting us on the web at www.pennbarry.com. PennBarry | www.pennbarry.com | [email protected] | tel: 972.212.4700 | fax: 972.212.4702 PennBarry reserves the right to make changes at any time, without notice, to models, construction, specifications, options, availability, etc. This bulletin illustrates the appearance of PennBarry products at the time of publication. View the latest updates on the PennBarry website. © Copyright 2014 PennBarry. All Rights Reserved. FUMEX FEBRUARY 2014
Similar documents
General Purpose Centrifugal Fan, Model US
US Unipak fans consist of a standard up blast US unit attached to a fully welded inlet plenum and mounted on a curb cap. The resulting curb mounted assembly provides a unique solution to restaurant...
More information