Corning_copper (PDF 10,6 MB)
Transcription
Corning_copper (PDF 10,6 MB)
Corning Cable Systems Solutions for Premises Networks Copyright © 2005 All rights reserved. This publication must not be reproduced or copied in any way whatsoever without the express consent in writing of Corning Cable Systems GmbH & Co. KG. All Corning Cable Systems products described in this catalog are subject to availability and technical modification. Corning Cable Systems GmbH & Co. KG reserves the right to improve, enhance or otherwise modify Corning Cable Systems product without prior notification, including and in particular technical data and other information about such products. There is no legal obligation to supply a specific product to a precise specification until a binding order is accepted by Corning Cable Systems GmbH & Co. KG. Order No. EUR-221-EN Printed in Germany Corning Cable Systems GmbH & Co. KG Rotherstrasse 21 10245 Berlin, Germany LANscape® Solutions FutureCom™ Copper Products Corning Cable Systems LANscape® Solutions FutureCom™ Copper Products Catalog Issue 1, EMEA Corning Cable Systems FutureCom E System 55 5 FutureCom D System 81 6 FutureCom UE System 101 7 FutureCom UD System 115 8 Hardware 127 9 Telephone / ISDN Products 165 10 Cable for Patch Cords 169 11 Industrial Cable 175 12 Special Cable 183 13 Further Information 205 Corning Cable Systems 1 FutureCom F 4 FutureCom 10TEN 41 FutureCom E FutureCom 10 TEN System FutureCom D 3 FutureCom UD FutureCom UE 13 Hardware FutureCom™ F System Flex Wire Cable Telephone / for Patch Cord ISDN Products 2 Industrial Cable 3 Special Cable Introduction Further Information 1 Introduction Table of contents LANscape and UniCam are registered trademarks of Corning Cable Systems Brands, Inc. FutureCom, FutureLink, Pretium, FutureCom 10TEN, LSZH and Plug & Play are trademarks of Corning Cable Systems Brands, Inc. Discovering Beyond Imagination is a registered trademark of Corning Incorporated. All other trademarks are the properties of their respective owners. Corning Cable Systems is ISO9001 and ISO 14001 certified. 2 Corning Cable Systems 4 1.2. Corning Quality 5 1.3. Corning Cable Systems Global Locations 6 1.4. Standards for Structured Cabling 8 1.5. System Description 9 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D 1.5.1. LANscape® Structured Cabling FutureCom F 1.1. Corning - A Reliable Partner FutureCom 10TEN 3 FutureCom E Introduction Further Information 1 Introduction Table of contents Corning Cable Systems 3 Corning Quality Corning Incorporated is a diversified technology company Corning’s own complete system for structured cabling, on with a proud history of developing breakthrough technolo- the basis of copper cable, followed in 1990. Since then, Corn- years, integrating scientific discovery with market need. We world, Corning started using 600 MHz technology for sym- gies that significantly improve people’s lives. We have been changing the world through innovation for more than 150 focus on high-impact growth opportunities in the telecommunications, flat panel display, environmental, life sciences and semiconductor industries. Corning is a reliable partner that meets the communication requirements of its customers all over the world with costeffective solutions. In 2000 Corning grouped all its cable, hardware and equipment businesses into the Corning Cable Systems division. Corning Cable Systems now comprises the former Siecor Corporation, the communication cables business from BICC (Corning Cables), Siemens’ former Communication Cables division and RXS Kabelgarnituren. Norddeutsche Seekabelwerke (NSW) also belongs to Corning Incorporated and is continuing to operate as a separate company. ing has always been a market leader and the technology leader for cabling systems. In 1995, for the first time in the metrical copper cabling systems. Today, with LANscape® FutureCom™, Corning offers a com- plete system of copper components with bandwidths of 100 to 1500 MHz and the experience of installing more than 15 million ports. This can also be combined with modular fiber optic hardware and FutureCom™ cable components. LANscape - the combination of FutureCom™ copper and fiber optic products - thus offers the optimal solution for every network. Our quality and environmental management systems are certified to DIN EN ISO 9001 and ISO 14001. Our global pres- ence is your gain because, wherever you are, Corning is close at hand. In the field of fiber optic cable technology, Corning was one of the original pioneers, with expertise second to none. As early as 1974, when fiber optic technology was still in its in- fancy, Corning was working with Europe’s leading Public Telecommunications companies in developing trial fiber optic routes. The end of the 90s saw the beginning of local networks on the basis of today’s network protocols - and Corning was actively involved from the start. 4 Corning Cable Systems Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN Corning Cable Systems is committed to providing excellent product Corning Cable Systems 5 Introduction quality and customer support services. FutureCom F Corning Quality Corning Cable Systems Global Cable and Hardware Businesses Whiston, Great Britain Derby, Great Britain Aberdeen, Great Britain Deeside, Wales Headquarter, Hickory NC, USA Favières, France Winston-Salem, NC, USA Keller, TX, USA Santo Domingo, Dominican Republic Reynosa, Mexico Rio Grande, Puerto Rico Boca Raton, FL, USA 6 Corning Cable Systems Madrid, Spain Hagen, Germany Nordenham, Germany Berlin, Germany Neustadt, Germany Lodz, Poland Munich, Germany Turin, Italy Hickory, North Carolina, USA. Corning Cable Systems EMEA Headquarters is located in FutureCom E FutureCom 10TEN FutureCom F Berlin, Germany. Introduction Corning Cable Systems Global Headquarters is located in FutureCom D Moscow, Russia FutureCom UD FutureCom UE Gebze, Türkei Tokyo, Japan Amman, Jordan Bangkok, Thailand Shanghai, China Makati City, Phillipines Kuala Lumpur, Malaysia Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware Singapore, Singapore Further Information Special Cable Industrial Cable Clayton, Australia Corning Cable Systems 7 Standards for Structured Premises Cabling Solutions The requirements of future-proof and flexible structured cabling are largely determined by three fundamental cabling standards addressing specific geographic regions: Standard Europe North America World Description EN 50173-1 (2003) Cabling Standard Information Technology Generic Cabling Systems TIA/EIA 568 B. 1 (2001) / B.2 1 (2001) Commercial Building Telecommunications Cabling Standard ISO/IEC 11801 Edition 2002 Cabling Standard, Generic Cabling for Customer Premises The TIA/EIA is not a standard as such, but an industry specification in the North American market. It also contains requirements regarding the transmission characteristics of cabling and components that differ from those of the EN or ISO/ IEC. It has its origins in the specification of unshielded copper components. Campus Building distributor distributor Fiber 1500 m Campus Backbone 8 Floor distributor Fiber (copper) 500 m Telecommunication Building Backbone outlet Copper / Fiber Copper / Fiber 90 m Horizontal Substystem 100 m incl. patch and connecting cords Corning Cable Systems Terminal equipment LANscape® Structured Cabling Building cabling can utilize cabling with both symmetrical copper cables and components and fiber optic cables and one location with each other. The campus distributor forms The cabling is installed in a star shape radiating out from the center of primary cabling. Due to the relatively long transmission paths, only fiber optic cabling is worth considering. Corning offers a fiber optic modular cabling solution which can be combined with copper-component cabling systems. For the campus environment, mainly single-mode fiber cable is used, which distinguishes itself by its low at- tenuation and high bandwidth. A further argument for fiber optic cable in this area is its electromagnetic insensitivity. Building Backbone In the horizontal subsystem, mainly copper cable is used. the horizontal distributor to the individual connection boxes. The distance, however, should not exceed 90 m, since the cabling would then no longer comply with the standard. An additional option in the horizontal area is “fiber to the desk” (FTTD), i.e. fiber optic cabling to the workstation. This is used for high bandwidth or long distance centralized cabling applications. FutureCom UD FutureCom UE Campus cabling (backbone) links the individual buildings in FutureCom E Horizontal Subsystem FutureCom D Campus Backbone FutureCom 10TEN FutureCom F Introduction components. In the primary area, only fiber optic cables and components are used. The connection between the building distributor and the various horizontal distributors is designated as the second- ary area. It represents the backbone of the building. The cabling of the vertical area can be carried out with both symmetrical copper cables and fiber optic cables. “High-end” copper data cable (bandwidths up to 1500 MHz), such as Hardware those you can find in the Corning FutureCom™ product range, can also be used in the secondary area for lengths up Flex Wire Cable Telephone / for Patch Cord ISDN Products to 100 m. For increased bandwidth requirements, fiber optic cables (generally multi-mode fiber cables) are recommended in Further Information Special Cable Industrial Cable this area for greater future security . Corning Cable Systems 9 LANscape® Structured Building Cabling Horizontal Subsystem: FutureCom™ Outlets and Outlet Accessories (see pages 128-143) 10 Corning Cable Systems Horizontal Subsystem: FutureCom Data Cables S/FTP, F/FTP, SF/UTP, F/UTP or UTP (see system chapters in this catalog) Introduction FutureCom F Horizontal Subsystem: FutureCom Floor Distributors 19“ Patch Panels (see pages 152-156 or the LANscapeFiber Optic Campus Backbone – Backbone Cabling: Fiber Optic Cables (see the LANscape Fiber Optic Catalog, Building Backbone – Vertical Area Cabling: (see pages 152-156 or the LANscape® Fiber Optic in this catalog) FutureCom 19“ Distribution Panels or 19“ Patch Panels Catalog, EUR-220-EN) Fiber Optic Cable or FutureCom S/FTP, F/FTP, SF/UTP, F/UTP (see the LANscape Fiber Optic Catalog or system chapters Corning Cable Systems 11 Further Information Building Backbone – Horizontal Distributor: Special Cable Industrial Cable EUR-220-EN) Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE Catalog, EUR-220-EN) FutureCom D Campus Backbone – Building Distributor: FutureCom E FutureCom 10TEN (see pages 144-151) 12 Corning Cable Systems 2.4.1. S1200 Modules and Connectors Overview 21 2.4. Connecting Hardware 2.4.2. Modules and Module Accessories 22 2.4.4. Tools 25 23 2.4.3. S1200 Connectors 2.5. Hardware 2.5.1. Outlets and Outlet Accessories 26 2.5.2. Floor Box Solutions 29 2.5.4. Consolidation Point Housing for S1200 Module 32 2.6.1. Cat. 7 Patch Cords 33 2.5.3. Patch Panels 31 2.6. Patch Cords 2.6.2. Cat. 6 Patch Cords 34 2.6.4. UTP Flex Patch PVC Cords 37 2.6.3. Cat. 5 Patch Cords 35 2.6.5. TV Connecting Cable 38 2.7. Plug & Play™ 39 40 Special Cable 2.8. Test Adapter Cable FutureCom F 18 FutureCom 10TEN 2.3.1. Cat 7. S/FTP 1500/22 and S/FTP 1200/22 Cables FutureCom E 2.3. Cable FutureCom D 17 FutureCom UD FutureCom UE 2.2. Certificates Hardware 14 Flex Wire Cable Telephone / for Patch Cord ISDN Products 2.1. System Descriptions & Data Industrial Cable FutureCom F Further Information 2 Introduction Table of contents Corning Cable Systems 13 FutureCom™ F System FutureCom F (2002) is Corning’s high-end system solution for symmetrical copper cabling. It satisfies all the requirements of the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards for Class F links and Category 7 for the components. The FutureCom F System is part of the Pretium™ Solutions family. Pretium Solutions is Corning Cable Systems’ high preformance solution set for fiber and copper premises networks. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S1200 Frame Set, for two S1200 Modules, Cat.7, inclined, CAXFSE-S0201-C001 SF/UTP flex/26, gray, 1xS1200/2 and 1xRJ45 connector, 2 pairs, for 10/100Base-T CCAFGD-D1024-A030-C1 FutureCom S/FTP 1200/22 CCXFCB-L0047-C001-L7 S1200 Module, 1xS1200, shielded, Cat. 7 CAXFSM-00100-C001 S1200 19“ Patch Panel, for max. 24 S1200 Modules, with integrated cable strain relief, 1 U, front panel of high-grade steel CAXFSV-02400-C001 S/FTP flex/26, rot, 1xS1200/4 and 1xRJ45- connector, 4 pairs, for 10/100/1000 Base-T CCAFGB-G5021-A020-C0 SF/UTP flex/26, gray, Cat.7, 2xS1200/2 connectors, 2 pairs CCAFGB-G1026-A020-C1 The highest level of system performance up to 10GBase-T for The FutureCom F system offers technical transmission The resulting performance and future security guaranty the addition, it enables the optimal utilization of cabling FutureCom F cabling conforms with the standards and is The performance of the FutureCom F cabling system has the complete link is achieved through the utilization of high-quality Category 7 cables, connectors and patch cords. maximum level of investment protection for cabling. outstandingly well suited for all recognized standardized voice and data transmission procedures. This applies to analog voice transmission, ISDN, Token Ring, Ethernet (10-BaseT), Fast Ethernet (100Base-TX), Gigabit Ethernet, 10 Gigabit Ethernet, 100Base-VG and ATM. 14 possibilities similar to those of optical cabling systems and permits multimedia applications, such as TV transmission. In through the use of 2-pair patch cords (cable sharing). been certified by an independent testing body (see certificate). Of course, all EMC values standardized in Europe are observed. Corning Cable Systems ACR in dB (typ. FutureCom F values) Min. ELFEXT in dB* ELFEXT in dB (typ. FutureCom F values) Min. return loss in dB* Return loss in dB (typ. FutureCom F values) * According to ISO/IEC 11801 (2002) 61.0 5.3 – 102.1 93.7 65.0 – 7.5 – 88.5 – 103.0 95.0 91.0 19.0 21.0 – 21.0 – – 21.0 – 13.4 – 75.6 – 100 20.8 17.1 155.5 250 33.8 – 21.4 62.9 – 42.1 21.0 – 56.9 23.1 68.9 60.6 50.5 – 44.4 – 83.0 79.0 74.0 – 27.5 12.0 21.0 21.0 – 37.8 600 54.6 43.5 51.2 19.0 52.3 1000 1200 – – 57.6 68.0 60.0 58.0 24.5 –3.4 31.3 68.0 54.0 8.0 850 – 8.0 16.0 – 7.7 – 45.0 – 15.0 – – 0.4 – 41.0 – 14.0 – 69.2 53.0 – – – 30.0 – 10.0 – FutureCom D The system values cited only apply to the use of original FutureCom F products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown. FutureCom F Min. ACR in dB* 65.0 62.5 – FutureCom 10TEN 104.0 99.0 96.0 89.0 86.0 82.0 78.0 Min. NEXT in dB* 1.9 20 – FutureCom E NEXT in dB (typ. FutureCom F values) Attenuation in dB (typ. FutureCom™ F values) 10 – Attenuation and Near-end Crosstalk (NEXT) NEXT in dB (typ. FutureCom F values) min. NEXT in dB According to standard max. Attenuation in dB According to standard Attenuation in dB (typ. FutureCom F values) Further Information Special Cable Industrial Cable Frequency in MHz FutureCom UD FutureCom UE Max. attenuation in dB* 1 4.0 Hardware Frequency in MHz Flex Wire Cable Telephone / for Patch Cord ISDN Products Electrical Characteristics (at 20°C) Introduction FutureCom™ F System Data for Channel Class F (2002) Corning Cable Systems 15 FutureCom™ F System Data for Channel Class F (2002) Far-end Crosstalk Relating to the Far End (ELFEXT) ELFEXT in dB (typ. FutureCom™ F values) Min. ELFEXT in dB According to standard Frequency in MHz Return Loss Return loss in dB (typ. FutureCom F values) min. Return loss in dB According to standard Frequency in MHz Test Setup FutureCom F F/STP flex/26 Test Adapter Cable, 2 m S1200 Module 90 m FutureCom F/STP 1200/22 S1200 Patch Panel 19“ FutureCom F F/STP flex/26 Test Adapter Cable, 2 m 16 Nominal intrinsic impedance 100 V Max. DC loop resistance (according to standard) 40 V Max. delay (according to standard) 0.05 µs DC loop resistance (typ. FutureCom F values) Max. delay (according to standard) Corning Cable Systems 15 V , 0.02 µs Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ F Certificates Corning Cable Systems 17 FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22 Braided shield Halogen-free sheath, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Copper conductor AWG 22 Application The FutureCom™ S/FTP 1500/22 and S/FTP 1200/22 cables are designed for applications up to 1500/1200 MHz. Their transmission characteristics significantly exceed the requirements defined by today’s Category 7 specifications (EN50288). FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit Ethernet. The possibility of using the cable up to the GHz area enables the highest possible transmission rates for multimedia applications such as TV transmission, in future-proof networks. Each pair is individually foil shielded (FTP). The stranded pairs (PiMF) are also sheathed with a braid shield (S/FTP), which guarantees outstanding shielding characteristics. The Mechanical Characteristics Conductor insulation cable satisfies Class B interference radiation standards (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Halogen-free Foam-skin material Outer jacket Halogen-free, Temperature range (installation) 0 to +50°C Area/range of application Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 18 flame retardant Dry and damp rooms -20 to +60°C >_ 45 mm (for 2x (4x2...) over flat side) >_ 65 mm (for 2x (4x2...) over flat side) AWG 22 Features Specified up to 1500 MHz / 1200 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight Low skew between the pairs Halogen-free (LSZH) Fire retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 Corning Cable Systems FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22 Introduction >5000 MV x km 125 V +/– 20 % >46 dB at 64 kHz Propagation velocity 0.77 x c for S/FTP 1200 FutureCom 10TEN <2 m V/m at 10 MHz Surface transfer impedance >40 dB at 1 MHz Unbalance to ground dB/BZL = 100 m >20 dB at 100 MHz Unbalance to ground dB/BZL = 100 m FutureCom E 0.76 x c for S/FTP 1500 at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 4.2 ns/m 6 ns/100 m Delay skew Electrical Characteristics (at 20°C) for S/FTP 1500/22 Frequency in MHz 1 10 16 31.25 62.5 100 300 600 NEXT in dB at 100 m * 80.0 80.0 80.0 80.0 75.1 72.4 65.3 60.8 Attenuation in dB/100m * Typical values dB/100m Typical values in dB at 100 m PSNEXT in dB at 100 m * Typical values in dB at 100m ELFEXT in dB at 100 m * Typical values in dB at 100m PSELFEXT in dB at 100 m * Typical values in dB at 100m ACR in dB 2.0 1.7 5.7 5.3 7.2 6.8 10.1 9.7 77.0 102.0 80.0 96.0 77.0 93.0 103.3 77.0 102.0 74.0 96.0 71.0 93.0 99.7 Frequency in MHz 1 10 NEXT in dB at 100 m * 80.0 80.0 Typical values dB/100m 13.8 77.0 102.0 69.9 96.0 66.9 93.0 98.2 77.0 102.0 64.1 93.0 61.1 90.0 95.3 2.0 5.7 16 7.2 20 8.1 72.5 102.0 58.1 88.0 55.1 85.0 91.2 PSELFEXT in dB at 100 m * 77.0 ELFEXT in dB at 100 m * Typical values in dB at 100m Typical values in dB at 100m ACR in dB 1.6 4.9 6.4 80.0 74.0 69.9 68.0 64.1 94.0 94.0 94.0 94.0 91.0 96.0 103.3 96.0 71.0 100.1 96.0 93.0 66.9 65.0 98.6 98.0 69.4 102.0 54.0 82.0 51.0 79.0 87.5 10.1 Typical values in dB at 100m PSNEXT in dB at 100 m * 17.5 31.25 7.0 9.0 80.0 80.0 80.0 >105.0 >105.0 >105.0 >105.0 >105.0 77.0 77.0 77.0 77.0 77.0 103.0 103.0 103.0 103.0 103.0 Typical values in dB at 100 m 18.5 33.3 30.8 >105.0 >105.0 >105.0 >105.0 >105.0 >105.0 103.0 Electrical Characteristics (at 20°C) for S/FTP 1200/22 Attenuation in dB/100m * 14.5 93.0 61.1 96.0 62.3 48.9 44.0 95.0 57.8 100.0 92.0 44.5 68.0 41.5 5.0 72.2 38.4 55.0 35.4 52.0 51.0 1000 57.8 – 85.0 – 82.0 37.0 – 34.0 – 27.2 62.5 100 300 600 75.1 72.4 65.3 60.8 14.5 12.8 18.5 16.5 33.3 28.9 >105.0 >105.0 102.0 72.5 103.0 58.1 88.0 55.1 86.0 92.2 69.4 103.0 54.0 82.0 51.0 80.0 88.5 62.3 48.9 47.1 95.0 57.8 100.0 93.0 44.5 70.0 41.5 68.0 73.1 38.4 55.0 35.4 53.0 53.3 1200 63.6 – 80.0 – 77.0 31.0 – 28.0 – 16.4 1500 72.0 – 75.0 – 72.0 24.0 – 21.0 – 3.0 1000 1200 54.5 – 85.0 – 83.0 40.0 – 38.0 – 30.5 59.8 – 80.0 – 78.0 35.0 – 33.0 – 20.2 * Standard: Requirements for 100 m installed Category 7 cable for Class F cabling sections (complies with EN 50288-4-1 and IEC 61156-7) Corning Cable Systems FutureCom D Unbalance to ground dB/BZL = 1000 m 100 V +/– 25 % Impedance Zo at 251 - 600 MHz FutureCom UD FutureCom UE 100 V +/– 18 % Hardware Impedance Zo at 101 - 250 MHz FutureCom F 100 V +/– 15 % Impedance Zo at 1 - 100 MHz Flex Wire Cable Telephone / for Patch Cord ISDN Products Impedance Zo at 0.064 MHz Industrial Cable Insulation resistance 1% 19 Special Cable Largest resistance margin Further Information Electrical Characteristics (at 20°C) FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22 Ordering Information Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number S/FTP 1500/22 8P 7+ S/FTP 1500/22 4P S/FTP 1200/22 4P S/FTP 1200/22 8P 20 7+ 4 0.67 Yes 179 7.7 7+ 8 1.34 Yes 358 7.7x16.5 133 7+ 8 4 1.34 0.67 Yes Yes 358 179 Corning Cable Systems 66 7.7x16.5 133 7.7 66 1000 CCXFCB-M0047-C001-L7 500 CCXFCB-L0087-C001-L6 500 1000 CCXFCB-M0087-C001-L6 CCXFCB-L0047-C001-L7 FutureCom™ F S1200 Modules and Connectors Introduction Features Category 7+ Module Up to 1200 MHz bandwith per pair Dust protection flap to prevent exposure to contaminants FutureCom F Wide range of installation options Few individual components High-level component density S1200 Adapter Removing the module icon (black plastic clasp on the upper side of the S1200 Module) enables the S1200 module to be inserted into the module adapter. The S1200 adapter ex- tends the application possibilities of the Cat. 7 module to many components in the LANscape® product range, such as: Patch panels Frame sets Hardware Floor box solutions FutureCom UD FutureCom UE FutureCom D Individual components of the S1200 Module FutureCom E FutureCom 10TEN Individual shielding of the modules Flex Wire Cable Telephone / for Patch Cord ISDN Products S1200 Module with adapter for LANscape® interface S1200 Connector Types For the FutureCom™ F System, the following connector types are offered: S1200/4 shielded connector, 4-pair Industrial Cable (for solid or stranded conductors) S1200/2 shielded connector, 2-pair S1200/1 shielded connector, 1-pair S1200 Connector Types Corning Cable Systems 21 Further Information Special Cable All patch cords modes can be created using these connectors. FutureCom™ F Modules and Module Accessories Features Bandwidths up to 1200 MHz per pair of wires Quick and easy to install IDC connection (IDC = Insulation Displacement Contacts) Universal usage (direct or with adapter) in many LANscape® components Negligible effect from interference through the individual shielding of the modules Ordering Information Order Number CAXFSM-00100-C001 Description S1200 module, 1 x S1200, shielded, Cat. 7+, for installation in LANscape patch panels, outlets and floor box mounting plates S1200 Module Adapter Order Number CAXFSN-00110-C001 Blank Covers Order Number CAXFSN-00101-C001 CAXFSN-00108-C001 22 Description S1200 module adapter, for the installation of the S1200 modules in LANscape patch panels, outlets and floor box mounting plates Description 1 slot for installation in FutureCom™ F S1200 patch panels, outlets and floor box mounting plates (S1200 direct assembly without module adapters) white, RAL 9010 black, RAL 9005 Corning Cable Systems Units per Delivery 1/1 Units per Delivery 6/1 Units per Delivery 10/1 10/1 FutureCom™ F S1200 Connectors Introduction Features Bandwidths up to 1200 MHz per pair Quick and easy to install IDC connection (IDC = Insulation Displacement Contacts) FutureCom F High density, i.e. for each module the following connector combinations can be used: – one 4-pair connector FutureCom 10TEN – two 2-pair connectors – one 2-pair connector and two 1-pair connectors – four 1-pair connectors Shielded connectors are designed for the use with S/FTP FutureCom E type cables S1200/4 Connector, shielded, Cat. 7+, Units per Delivery CAXFSS-00100-C004 1200/4 Connector, shielded, Cat. 7+, 1/1 4-pair, for solid wire AWG 22 to 23, Further Information Special Cable Industrial Cable e.g. for consolidation point cabling 1/1 Hardware 4-pair, for flex wire cables AWG 26 FutureCom UD FutureCom UE CAXFSS-00100-C001 Description Order Number Flex Wire Cable Telephone / for Patch Cord ISDN Products S1200/4 Connector 4-pairs, shielded, Cat.7+ FutureCom D Ordering Information Corning Cable Systems 23 FutureCom™ F S1200 Connectors Ordering Information S1200/2 Connector, 2-pair, shielded, Cat. 7+ Order Number CAXFSS-00100-C002 Description S1200/2 Connector, shielded, Cat.7+, 2-pair, for flex wire cable AWG 26 S1200/1 Connector, 1-pair, shielded, Cat. 7+ CAXFSS-00100-C003 24 S1200/1 Connector, shielded, Cat.7+, 1-pair, for flex wire cable AWG 26 Corning Cable Systems Units per Delivery 1/1 1/1 FutureCom™ F Tools Introduction Features of the S1200 Assembly Tool Integrated knife for the removal of the jacket Stripping option for the PiMF foils with a defined length Management for arrangement or shaping of the individual FutureCom F pairs (PiMF) CAXFSN-00000-C001 Description S1200 Tool, for the assembly of S1200 modules Units per Delivery FutureCom E Order Number 1/1 FutureCom D Ordering Information FutureCom 10TEN Defined section length of the wires and S1200/4 or 1/1 CAXCSN-00000-C004 Copper Conducting Tape, 12.7 mm wide, 2/1 Further Information roll length 16.5 m Special Cable the IDC contacts on FutureCom™ S1200 modules Hardware Comfort Parallel Pliers, for the termination of Flex Wire Cable Telephone / for Patch Cord ISDN Products CAXCSN-00000-C008 Industrial Cable Parralel Pliers and Copper Conducting Tape FutureCom UD FutureCom UE S1200/2 connectors Corning Cable Systems 25 FutureCom™ F Outlets and Outlet Accessories Features of the Frame Set Direct installation of S1200 modules Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates, as well as face plates from other manufacturers Designation window Ordering Information Order Number CAXFSE-S0201-C001 Description S1200 Frame Set, inclined, for 2 FutureCom™ S1200 modules, including mounting frame and 50x50 mm central plate with designation window, threaded, white RAL 9010 Units per Delivery 1/1 Features of the Frame Sets Installation of S1200 modules with module adapters Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates, as well as face plates from other manufacturers Designation window Order Number WAXWSE-V0201-C001 WAXWSE-V0202-C001 Description Frame Set, inclined, projecting, for 2 S1200 modules with module adapters, including mounting frame and 50x 50 mm central plate with designation window and dust protection flaps white, RAL 9010 pearl white, RAL 1013 Labeling icons and designations labels can be found on page 131. Brackets for raceway mounting can be found on page 134. 26 Corning Cable Systems Units per Delivery 1/1 1/1 FutureCom™ F Outlets and Outlet Accessories Introduction Features of the Universal Integration Housing Direct assembly of S1200 modules WAXWSE-V0201-C002 Description Universal Housing, inclined, projecting, for face plate (147x87 mm and 87x87 mm) for the direct integration of 2 S1200 modules, FutureCom 10TEN Order Number Units per Delivery 1/1 FutureCom E Ordering Information FutureCom F Surface mount housing suitable for the face plates; see page 136. Face Plate, 87x87 mm, for one housing, including two metric screws and FutureCom UD FutureCom UE WAXWSE-00001-C005 FutureCom D central partition provided, white, RAL 9010 1/1 two withworth screws, for frame assembly in installation outlets, white, RAL 9010 Hardware (Suitable Surface Mount Housing Face Plate, 87x147 mm, 1/1 for two housings, including two metric screws and two withworth screws, for frame assembly in installation outlets, white, RAL 9010 (Suitable Surface Mount Housing Special Cable Industrial Cable WAXWSE-00001-C006; see page 136) Further Information WAXWSE-00001-C007 Flex Wire Cable Telephone / for Patch Cord ISDN Products WAXWSE-00001-C004; see page 136) Corning Cable Systems 27 FutureCom™ F Outlets and Outlet Accessories Ordering Information Order Number Units per Delivery Description Frame Set, inclined, for 3 S1200 modules with module adapters, including mounting frame and triple housing with designation window WAXWSE-V0301-C001 WAXWSE-V0302-C001 and dust protection flaps, also as 80x80 mm face plate white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Frame Set, inclined, for 6 S1200 modules with module adapters, including mounting frame and two triple housings with designation window and WAXWSE-V0601-C001 WAXWSE-V0602-C001 Installation Option dust protection flaps, also as a 151x80 mm face plate white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Frame Set, inclined, for 6 S1200 modules with module adapters, including mounting frame and two triple housings with designation window and dust protection flaps, as well as 151 x 80 mm face plate, white, RAL 9010: WAXWSE-V0601-C001 equipped with four S1200 modules with module adapters CAXFSM-00100-C001 + CAXFSN-00110-C001 one triple MT-RJ OM3 module LAXLSM-00212-C002 two black labeling icons WAXWSE-00008-C001 two blue labeling icons Frame Set, inclined, projecting, for 6 modules, integrated into a raceway WAXWSE-00004-C001 two green labeling icons WAXWSE-00006-C001 one black SF/UTP flex/26 Cat. 5 Patch Cord CCAFGD-D6024-A020-C1 and one blue S/FTP flex/26 Cat. 6 Patch Cord CCAFGB-G2021-A030-C0 28 Corning Cable Systems FutureCom™ F Floor Box Solutions Introduction Features Specially designed for the direct integration of S1200 modules Stable metal construction, no additional installation FutureCom F trough required Integrated cable strain relief that can be mounted in various positions FutureCom 10TEN No screwing required Integrated grounding bolt Order Number CAXFSU-00600-C001 Description Mounting Panel for Ackermann Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 (outer) or GES 8/10, Units per Delivery FutureCom D Ordering Information FutureCom E Designation window with title strips 1/1 FutureCom UD FutureCom UE for the installation of 6 FutureCom™ F S1200 modules, with integrated cable strain relief and six cable ties, designation window, black Mounting Panel for Ackermann Floor Boxes GESR 7/10 (center), GES 9 or GESR 9, for the installation 1/1 Hardware CAXFSU-00900-C001 Flex Wire Cable Telephone / for Patch Cord ISDN Products of 9 FutureCom F S1200 modules, with integrated cable strain relief and nine cable ties, designation window, black 1/1 VanGeel Floor Box IK-1 (long), for the installation Industrial Cable Mounting Panel for of 9 FutureCom F S1200 modules, Special Cable with integrated cable strain relief and nine cable ties, designation window, black Further Information CAXFSU-00900-C005 Corning Cable Systems 29 FutureCom™ F Floor Box Solutions Ordering Information Order Number CAXFSU-00900-C002 Description Mounting Panel for Kleinhuis Floor Box GR. II and GR. III (outside only), for the installation of 9 FutureCom™ F S1200 modules, with integrated cable strain relief and nine cable ties, designation window, black Installation Option Mounting Panel for Kleinhuis Floor Boxes GR. II and GR. III (only left or right position): CAXFSU-00900-C002 The three 3-port mounting places are configured as follows: equipped with two S1200 modules, CAXFSM-00100-C001 one blank cover, white, CAXFSN-00101-C001 and two gray 2-pair SF/UTP flex/26 10/100BaseT Patch Cords CCAFGD-D1024-A030-C1 equipped with two S1200 modules, CAXFSM-00100-C001 one blank cover, black, CAXFSN-00108-C001 equipped with three S1200 modules, CAXFSM-00100-C001 and one blue S/FTP flex/26 Cat. 6 Patch Cords CCAFGB-G2021-A030-C0 For applications requiring fiber optic and copper solutions, the S1200 module can be integrated into the various floor box mounting panels from the LANscape® product range using an adapter (see pages 144-151). 30 Corning Cable Systems Units per Delivery 1/1 FutureCom™ F S1200 Patch Panels Introduction Features Specially designed for the direct integration of S1200 modules Integrated shielded transitional spring Order Number CAXFSV-02400-C001 Description S1200 Patch Panel 19“, shielded, Cat. 7+, including 24 FutureCom™ F S1200 modules, with integrated cable strain relief and shielded Units per Delivery FutureCom E Ordering Information FutureCom 10TEN FutureCom F Patch panel accessories, see page 156 1/1 S1200 Patch Panel 19“, for max. 24 FutureCom F S1200 modules, with integrated cable strain relief and shielded FutureCom UD FutureCom UE CAXFSV-02400-C002 FutureCom D transitional spring, 1 U, high-grade steel 1/1 transitional spring, 1 U, for max. 12 FutureCom F S1200 modules, with integrated cable strain relief and shielded 1/1 Flex Wire Cable Telephone / for Patch Cord ISDN Products S1200 Patch Panel 10“, transitional spring, 1 U, Special Cable Industrial Cable high-grade steel front panel Further Information CAXFSV-01200-C001 Hardware high-grade steel Corning Cable Systems 31 Consolidation Point Housings for S1200 Modules Features Full metal housing for the installation of up to 12 FutureCom™ S1200 modules Standard-compatible according to ISO/IEC 11801 (2002) and EN 50173-1 (2003) Easy installation for a distribution or consolidation point Consolidation point housing is suitable for ceiling, wall, false floor or desk assembly Individual strain relief for the incoming and outgoing cable sections Dust-proof feedthrough for incoming cable Easy plug-in of consolidation point cable (dust protection and mechanical protection) Housing base electrically conductive for optimal shielding transition or grounding Installation height of 60 mm Housing is fastened using special non-detachable screws Black sheet steel housing top, RAL 9005 Ordering Information Order Number Description WAXWSW-00008-C014 Consolidation Point Housing for max. 12 FutureCom F S1200 modules, with strain relief for incoming data cables, patch cord strain relief and dust protection flap for floor, wall and ceiling installation, 60 x 263 x 320 mm (HxWxD) 32 Corning Cable Systems Units per Delivery 1/1 FutureCom™ F Cat. 7 Patch Cords S1200 to S1200 Introduction Description FutureCom F Category 7 patch cords are available in two or four pair versions with foil and full braided shielding (S/FTP). They are pre-terminated with shielded S1200 connectors on FutureCom F both ends and are available in various lengths. The patch cords meet all the transmision property requirements for FutureCom 10TEN Channel F (2002). Features FutureCom E S/FTP flex cable, specified up to 600 MHz S1200/4 connector pair fully configured and application-neutral FutureCom D S1200/4 connector pair for up to 10GBase-T applications S1200/2 connector pair fully configured on both sides Minimum surface transfer impedance (<10 mV/m at 10 MHz) 010 015 020 030 040 050 060 100 = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 10 meters 1 1 - C1 Select length. 010 015 020 030 040 050 060 100 = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 10 meters Hardware CCAFGB - G1026 - A Flex Wire Cable Telephone / for Patch Cord ISDN Products Select length. - C0 Industrial Cable 1 1 Special Cable CCAFGB - G1022 - A Further Information Ordering Information FutureCom UD FutureCom UE Outstanding transmission characteristics Corning Cable Systems 33 FutureCom™ F Cat. 6 Patch Cords S1200/4 to RJ45 Description Application-neutral, Category 6 S/FTP patch cords with four pairs are pre-terminated with S1200/4 and RJ45 connectors. The patch cords meet all the transmision property requirements for Channel E (2002) and Cat. 6 (2002). Features S/FTP flex cable, specified up to 600 MHz Pre-terminated with S1200/4 on one end and RJ45 on the other end Minimum surface transfer impedance (<10 mV/m at 10 MHz) Outstanding transmission characteristics 4-pair, AWG 26, Cat. 6 (2002) Ordering Information CCAFGB - G 1 Select color. 2 Select length. 1 2 3 4 5 6 = = = = = = gray blue yellow green red black 010 015 020 030 040 050 060 080 100 150 = = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters 15 meters 34 1 021 - A 2 - C0 Corning Cable Systems FutureCom™ F Cat. 5 Patch Cords S1200/4 to RJ45 Introduction Description Application-neutral, Category 5 SF/UTP patch cords with four pairs are pre-terminated with S1200/4 and RJ45 connectors. The patch cords meet all the transmision property require- FutureCom F ments for Channel D (2002) and Cat. 5 (2002). FutureCom 10TEN Features SF/UTP flex cable, specified up to 300 MHz FutureCom E Pre-terminated with S1200/4 and RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz) FutureCom D Outstanding transmission characteristics Select length. = = = = = = gray blue yellow green red black 010 015 020 030 040 050 060 080 100 = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters Hardware 2 1 2 3 4 5 6 - C0 Flex Wire Cable Telephone / for Patch Cord ISDN Products Select color. 2 Industrial Cable 1 1 021 - A Special Cable CCAFGF - D Further Information Ordering Information FutureCom UD FutureCom UE 4 Pair, AWG 26, Cat. 5 (2002) Corning Cable Systems 35 FutureCom™ F Cat. 5 Patch Cords S1200/2 to RJ45 Description Category 5 SF/UTP patch cords with two pairs are pre-terminated with S1200/2 and RJ45 connectors. The patch cords meet all the transmision property requirements for Channel D (2002) and Cat. 5 (2002). Features SF/UTP flex cable, specified up to 300 MHz Pre-terminated with S1200/2 and RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz) Outstanding transmission characteristics 2 Pair, AWG 26, Cat. 5 (2002) Ordering Information For 10/100 Base-T Applications (Pins 1.2 - 3.6) CCAFGD - D 1 Select color. 2 Select length. 10 60 010 015 020 030 040 050 060 080 100 150 36 = = = = = = = = = = = = 1 24 - A gray black 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters (gray only) 10 meters (gray only) 15 meters (gray only) 2 - C1 For TR/ISDN and Analog Applications (Pins 4.5 - 3.6) CCAFGD - D 1 2 Select color. 1 24 - A 11 = gray 41 = green Select length. 010 015 020 030 040 050 060 080 100 150 Corning Cable Systems = = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters (gray only) 10 meters (gray only) 15 meters (gray only) 2 - C1 FutureCom™ F U/UTP Flex Patch Cords Introduction Description FutureCom™ F U/UTP flex FRNC patch cords are pre- terminated with S1200/1 or S1200/2 and RJ45 or RJ11/12 FutureCom F connectors for service specific applications. FutureCom 10TEN Features U/UTP flex cable, specified up to 100 MHz Pre-terminated with S1200/1 or S1200/2 connectors FutureCom E Pre-terminated with RJ11/12 or RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz) 1 Select application. 2 Select connector types. 1 0 = = 2 Pair, TR/ISDN and analog (4.5 - 3.6) 1 Pair, Telephone / Neutral 24 25 27 28 34 = = = = = S1200/2 to RJ45 S1200/2 to RJ11 S1200/1 to RJ45 (Telephone) S1200/1 to RJ11 (Telephone) S1200/1 to S1200/1 (Neutral) 010 015 020 030 040 050 060 080 100 = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters 3 - C0 Special Cable Select length. Further Information 3 2 -A Hardware 1 Flex Wire Cable Telephone / for Patch Cord ISDN Products CCAFFE - A6 Industrial Cable Ordering Information FutureCom UD FutureCom UE FutureCom D FRNC cable, unshielded Corning Cable Systems 37 FutureCom™ F TV Connecting Cable Features S1200/1 connector and balun (connector or jack) for the conversion of Cat.7+ cabling into coaxial cabling incl. impedance adjustment Very low surface transfer impedance (<10 mV/m at 10 MHz) Specifications Insertion Attenuation Back-to-back Return loss (75 V (100 V Measured at the 75 V end 100 V) < 2 dB 75 V) < 3.5 dB The 100 V end is terminated with a resistor of 100 V. Surface transfer impedance Rk [mV] Ordering Information Order Number Description < 19 dB < 12 dB < 20 mV Length CCAFGB-I4054-A030-C0 FutureCom™ TV/CATV Patch Cord, 3m* CCAFGB-I4055-A030-C0 FutureCom TV/CATV Patch Cord, 3m* * Other lengths upon request 38 1 x S1200/1 and 1xTV connector (IEC60169-2), FRNC sheath, green 1 x S1200/1 connector and 1 xTV jack (IEC60169-2), FRNC sheath, green Corning Cable Systems Frequency Range 5...300 MHz 300...450 MHz 5...300 MHz 300...450 MHz 10 MHz FutureCom™ F Plug & Play™ Solution Introduction Application The S1200 Solution Packages are factory pre-terminated cables. They are offered with FutureCom™ S/FTP 1200/22 cables, and enable Plug & Play™ installation, significantly reducing installation time. The assemblies are 100% factory tested, preventing installation faults on-site. CCAFCB-M2042-A250-C0 CCAFCB-M2042-A300-C0 CCAFCB-M2042-A350-C0 CCAFCB-M2042-A400-C0 CCAFCB-M2042-A450-C0 CCAFCB-M2042-A500-C0 CCAFCB-M2042-A550-C0 CCAFCB-M2042-A600-C0 CCAFCB-M2042-A650-C0 CCAFCB-M2042-A700-C0 CCAFCB-M2042-A750-C0 CCAFCB-M2042-A800-C0 CCAFCB-M2042-A850-C0 CCAFCB-M2042-A900-C0 CCAFCB-M2042-A950-C0 S1200 Solution Package S/STP1200/22 - 10 10 m S1200 Solution Package S/STP1200/22 - 25 25 m S1200 Solution Package S/STP1200/22 - 15 S1200 Solution Package S/STP1200/22 - 20 S1200 Solution Package S/STP1200/22 - 45 45 m S1200 Solution Package S/STP1200/22 - 40 S1200 Solution Package S/STP1200/22 - 50 S1200 Solution Package S/STP1200/22 - 55 S1200 Solution Package S/STP1200/22 - 60 S1200 Solution Package S/STP1200/22 - 65 35 m 40 m 50 m 55 m 60 m 65 m S1200 Solution Package S/STP1200/22 - 70 70 m S1200 Solution Package S/STP1200/22 - 85 85 m S1200 Solution Package S/STP1200/22 - 75 S1200 Solution Package S/STP1200/22 - 80 S1200 Solution Package S/STP1200/22 - 90 S1200 Solution Package S/STP1200/22 - 95 Description CP Solution Package S/FTP1200/22, 4 pairs, application-neutral, FRNC jacket, FutureCom 10TEN 20 m 30 m S1200 Consolidation Point Solution Packages Order Number 15 m S1200 Solution Package S/STP1200/22 - 30 S1200 Solution Package S/STP1200/22 - 35 FutureCom E with 2 S1200 Modules FutureCom D CCAFCB-M2042-A200-C0 FRNC jacket, pre-terminated FutureCom UD FutureCom UE CCAFCB-M2042-A150-C0 data cable, 4 pairs, application neutral, Length Hardware CCAFCB-M2042-A100-C0 Description Solution Package with S/FTP 1200/22 75 m 80 m Flex Wire Cable Telephone / for Patch Cord ISDN Products Order Number 90 m 95 m Length Industrial Cable S1200 Solution Packages FutureCom F Ordering Information CCAFCB-M2058-A100-C0 CCAFCB-M2058-A150-C0 CCAFCB-M2058-A200-C0 for consolidation points CP Solution Package S/STP1200/22 -5 CP Solution Package S/STP1200/22 -10 CP Solution Package S/STP1200/22 -15 CP Solution Package S/STP1200/22 -20 5m 10 m 15 m Further Information CCAFCB-M2058-A050-C0 connector and one S250 module Special Cable pre-terminated with one S1200/4 20 m Corning Cable Systems 39 FutureCom™ F Test Adapter Cables Applications For acceptance tests, special Test Adapter Cables are needed for the Fluke DSP 4x00 and Microtest OMNIScanner/- OMNIScanner 2 testers in accordance with Class F (2002). A pair of these test adapter cables is always required to perform the test. Ordering Information CCAFGB-G20ME-A020-C0 Description S1200 Test Adapter Cable, 2 m, Units per Delivery CCAFGB-G20MM-A020-C0 S1200 Test Adapter Cable, 2 m, for Microtest 2/1 Order Number for Fluke DSP 4x00 (per pair) OMNIScanner/OMNIScanner 2 (per pair) If you require test adapter cables for other testing equipment (e.g. LANTEK 7), please contact the relevant manufacturer directly. 40 Corning Cable Systems 2/1 3.3. Cable 46 3.4. Connecting Hardware 3.4.1. S10TEN Module Overview 47 3.4.2. S10TEN Module 48 3.5.1. S10TEN Outlets 49 3.5. Hardware 3.5.2. S10TEN Patch Panels 49 3.6.1. 10GBase-T Patch Cords 50 3.6. Patch Cords 3.6.2. Consolidation Point Patch Cords 51 3.7. Plug & Play™ 52 54 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware 3.8. Test Cable FutureCom F 45 FutureCom 10TEN 3.2. Certificate FutureCom E 42 FutureCom D 3.1. System Descriptions & Data FutureCom UD FutureCom UE FutureCom™ 10TEN System Further Information 3 Introduction Table of contents Corning Cable Systems 41 FutureCom™ 10 System TEN Corning Cable Systems’ FutureCom™ 10 System has been especially developed to support 10 Gigabit Ethernet (10GBase-T) TEN over 100 meters. FutureCom 10 is the latest addition to Pretium™ Solutions, Corning Cable Systems’ high-performance TEN fiber and copper solutions for premises networks, and is fully compliant with the IEEE 802.3an (Draft 2.0) standard for 10 Gigabit Ethernet transmission. The current FutureCom 10 is especially designed for 10 Gigabit applications in riser and TEN horizontal environments, avoiding alien near-end and far-end cross talk (ANEXT, AFEXT), in order to warrant the higher performance of cabling through immunity. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S10TEN outlet, 2xRJ45, 10GBase-T, inclined CAXTSD-S0201-C001 S/FTP flex/26, gray, 2xRJ45 connectors, 4 pairs, for up to 10 GBase-T CCATGD-G1002-A020-C0 FutureCom S/FTP900/23 CCXEDB-I0047-C001-L7 S10TEN Patch Panel 19“, for max. 24 S10TEN modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXTSV-02400-C001 S10 Module, 1 x RJ45,shielded, 10GBase-T CAXTSM-00112-C001 TEN S/FTP flex/26, gray, 2xRJ45- connectors, 4 pairs, for up to 10GBase-T CCATGB-G1002-A020-C0 A very high level of system performance is achieved for the It is suitable for all recognized standardized voice and data maximum future security and reliability. The performance of the FutureCom 10TEN cabling system has link through the use of high-quality 10GBase-T connection technology. The quality of the components guarantees Using all eight contacts in the RJ45 Connector as well as in the RJ45 Module, the cabling can be used universally and is application-independent. 42 transmission applications up to 10GBase-T. been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in Europe are observed. Corning Cable Systems FutureCom™ 10 System Data for Channel 10GBase-T 61.0 Min. ACR in dB according to standard * 88.1 ACR in dB (typ. FutureCom 10 values) TEN 63.3 Min. ELFEXT in dB* according to standard * 80.4 ELFEXT in dB (typ. FutureCom 10 values) TEN 19.0 Min. return loss in dB according to standard * 33.9 Return loss in dB (typ. FutureCom 10TEN values) * According to IEEE 802.3 an (draft 2.0). 85.3 78.5 – 61.9 – 32.7 – 8.0 75.0 – 66.6 – 56.4 – 30.7 – 63.6 57.9 14.3 – 49.5 – 52.9 – 32.4 – 18.1 39.9 18.2 40.1 23.3 51.8 12.0 32.1 155.5 200 – – 250 500 35.9 53.4 53.3 47.9 37.6 22.7 – 31.3 – 44.3 – 31.3 – 25.7 50.7 – 25.8 – 41.0 – 30.3 – 28.8 41.9 33.1 22.0 – 2.8 – 31.4 20.2 -2.0 15.3 38.1 7.2 9.3 31.3 6.0 26.5 22.1 The system values cited only apply to the use of original FutureCom 10TEN products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown. Attenuation and Near-end Crosstalk (NEXT) NEXT in dB (typ. FutureCom 10TEN values) min. NEXT in dB According to Standard max. Attenuation in dB According to Standard Attenuation in dB (typ. FutureCom 10TEN values) Further Information Special Cable Industrial Cable Frequency in MHz FutureCom F TEN – 100 21.7 FutureCom 10TEN Min. NEXT in dB according to standard * 5.6 62.5 – FutureCom E 89.4 65.0 20 – FutureCom D NEXT in dB (typ. FutureCom 10 values) 2.0 Attenuation in dB (typ. FutureCom 10TEN values) 10 – FutureCom UD FutureCom UE Max. attenuation in dB according to standard * 1 4.0 Hardware Frequency in MHz Flex Wire Cable Telephone / for Patch Cord ISDN Products Electrical Characteristics (at 20°C) Introduction TEN Corning Cable Systems 43 FutureCom™ 10 System Data for Channel 10GBase-T TEN Far-end Crosstalk Relating to the Far End (ELFEXT) ELFEXT in dB (typ. FutureCom 10TEN values) Min. ELFEXT in dB According to standard Frequency in MHz Return Loss Return loss in dB (typ. FutureCom 10TEN values) min. Return loss in dB According to standard Frequency in MHz Test Setup FutureCom 10TEN Test Cord, 2 m S10 TEN Module FutureCom F/STP 900/23 S10TEN Patch Panel 19“ FutureCom 10TEN Test Cord, 2 m 44 Nominal intrinsic impedance Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom 10TEN values) Max. delay (according to standard) Max. delay (typ. FutureCom 10TEN values) Corning Cable Systems 100 V 40 V 18 V 0.05 µs , 0.02 µs Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ 10 Certificate TEN Corning Cable Systems 45 FutureCom™ 10 10GBase-T Cables TEN Braided shield Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Features Copper conductor AWG 23 - AWG 22 Application The cables for the FutureCom™ S10TEN System are designed for applications up to 1500 MHz (S/FTP 600 up to S/FTP 1500*). Their transmission characteristics significantly exceed the requirements defined by today’s Category 7 specifications (EN50288-4-1). FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications running 10 Gigabit Ethernet. The possibility of using the cable up to the GHz area enables the highest possible transmission rates for multimedia applications, such as TV transmission, in future-proof networks. Each pair is individually foil shielded (FTP). The stranded pairs (PiMF) are also sheathed with a braid shield (S/FTP), Specified up to 1500 MHz which guarantees outstanding shielding characteristics. The Outstanding electrical characteristics cable satisfies Class B interference radiation standards Each pair is shielded (PiMF) (EN 55022), as well as immunity (EN 55024), which enables Full copper braid shield the realization of CE-compatible networks. Streamlined design Lightweight Low signal skew between the pairs Halogen-free (LSZH) Fire retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 * For S/FTP 600 and 900 cable please see pages 61-63. For S/FTP 1500 and 1200 cable please see pages 18-20. 46 Corning Cable Systems FutureCom™ S10 Module Overview TEN Introduction Features Fully compatible with all modular LANscape® systemes Wide range of installation options Few individual components FutureCom F High-level component density Individual shielding Halogen-free Individual Components of the S10TEN Module FutureCom D FutureCom™ S10TEN Technology FutureCom E FutureCom 10TEN Fire class UL94V-0 Optimized construction with printed circuit board for Proven IDC technology for wires with AWG 24 to AWG 22 Module reusable several times Disassembled S10TEN Module Application Wire management using TIA/EIA 568 A/B coding Transparent wire management allows direct control of correct wiring Installation in pairs (no untwisting of pairs is necessary) Industrial Cable Rapid assembly times Flex Wire Cable Telephone / for Patch Cord ISDN Products More than 1500 connector cycles are possible Hardware FutureCom UD FutureCom UE bandwidths of more than 500 MHz Easy handling S10TEN Wire Management, without/with cable Corning Cable Systems 47 Further Information Special Cable Compatible with all FutureCom S/FTP cables FutureCom™ 10 S10 Module TEN TEN Features Easy and quick to install, no special tools required IDC connection (IDC = Insulation Displacement Contacts) High-level component density Universal usage in all modular LANscape® and FutureCom™ components 10GBase-T Ordering Information Order Number CAXTSM-00112-C001 Description S10TEN Module, 1xRJ45, shielded, 10GBase-T, module aqua, with transparent TIA/EIA 568 A/B Unit per Delivery 1/1 wire management, incl. copper conducting tape for installation in LANscape modular patch panels, outlets and floor box solutions Cable Strain Relief Using the additional cable strain relief allows increased pulling forces on the module housings. Order Number CAXCSN-00000-C001 Description Additional cable strain relief, for fixing higher pulling forces on shielded FutureCom modules for solid wire, and for assembly of flexible consolidation point cables with FutureCom S10TEN fx, S250fx and U250fx modules 48 Corning Cable Systems Unit per Delivery 100/1 FutureCom™ 10 S10 Outlets and Patch Panels TEN TEN Order Number CAXTSD-S0201-C001 Unit per Delivery Description S10TEN Outlet, 2xRJ45, shielded,10GBase-T, inclined, incl. mounting frame FutureCom F S10TEN Outlets Introduction Ordering Information 1/1 FutureCom 10TEN with grounding flaps, central plate 50x50 mm with designation window, screw fixing, copper conducting tape S10TEN Outlet, 2xRJ45, shielded,10GBase-T, inclined, incl. mounting frame with 1/1 FutureCom D CAXTSD-S0202-C001 white, RAL 9010 FutureCom E (without faceplate), grounding flaps, central plate 50x50 mm FutureCom UD FutureCom UE with designation window, screw fixing, copper conducting tape (without faceplate) Order Number CAXTSV-02400-C001 Description S10TEN Patch Panel 19“, shielded, 10GBase-T, incl. 24 FutureCom S10TEN modules and copper conducting tape, Unit per Delivery Flex Wire Cable Telephone / for Patch Cord ISDN Products S10TEN Patch Panel Hardware pearl white, RAL 1013 1/1 with integrated strain relief, 1 U, for up to 24 FutureCom S10 TEN modules, with integrated strain 1/1 Special Cable S10TEN Patch Panel 19“, relief, 1 U, high-grade steel front panel Corning Cable Systems Further Information WAXTSV-02400-C001 Industrial Cable high-grade steel front panel 49 FutureCom™ 10 Patch Cords RJ45 to RJ45 TEN Description The FutureCom™ 10TEN System patch cords consist of Cate- gory 7 flexible cables with shielded RJ45 connectors at both ends. The flex cables have four individual foil-shielded pairs and full braid copper shielding. The zero halogen patch cords (LSZH) are non-corrosive (according to IEC 60754-2), low smoke (according to IEC 61034) and flame retardant (according to IEC 60332-1). FutureCom 10TEN patch cords provide additional latch protection. They are available in various lengths and colors. Features Flex cable specified up to 600 MHz Minimum surface transfer impedance (<10 mV/m at 10 MHz) Outstanding transmission characteristics for 10GBase-T Additional latch protection Ordering Information CCATGB - G 1 Select color. 1 2 3 4 5 6 50 = = = = = = gray blue yellow green red black 1 002 - A 2 2 - C0 Select length. 010 015 020 030 040 050 060 075 080 100 150 200 250 300 = = = = = = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters 20 meters (gray only) 25 meters (gray only) 30 meters (gray only) Corning Cable Systems FutureCom™ 10 Consolidation Point Patch Cords TEN Introduction Description The FutureCom™ 10TEN Consolidation Point Patch Cords are factory terminated cable assemblies with one S10TEN fx module and one RJ45 connector. FutureCom S/FTP flex/26 FutureCom F cable is specified up to 600 MHz and satisfies Category 7 transmission characteristics. The CP Patch Cords are suitable for connection from LANscape® Consolidation Point Hous- FutureCom E FutureCom 10TEN ings to wall or desktop outlets. Description S/FTP flex/26 Patch Cords, 4 pairs application-neutral, FRNC sheath, FutureCom UD FutureCom UE Order Number FutureCom D Ordering Information Length gray, pre-terminated with one RJ45 Other lengths upon request CP Patch Cords S/FTP flex/26 - 20 Hardware CP Patch Cords S/FTP flex/26 - 15 5m 10 m 15 m 20 m Flex Wire Cable Telephone / for Patch Cord ISDN Products CCATGB-F1062-A200-C0 CP Patch Cords S/FTP flex/26 - 10 Industrial Cable CCATGB-F1062-A150-C0 CP Patch Cords S/FTP flex/26 - 5 Special Cable CCATGB-F1062-A100-C0 for 10GBase-T applications Further Information CCATGB-F1062-A050-C0 connector and one S10TEN fx module, Corning Cable Systems 51 FutureCom™ 10 Plug & Play™ Solutions TEN Application The S10TEN Solution Packages are pre-terminated cables with S10TEN modules at both ends. They are generally offered with FutureCom™ S/FTP 900/23 cables. Both modules are equipped with additional cable strain relief to allow higher pulling force during installation (the pulling force is re- stricted by the cable only). They enable Plug and Play™ installation and therefore significantly reduce installation time. 100% factory testing reduces failures during installation. Ordering Information Order Number Description S10 Solution Package, with TEN S/FTP 900/23 cable, Length 4 pairs, FRNC jacket, pre-terminated CCATDB-F2063-A100-C0 CCATDB-F2063-A150-C0 CCATDB-F2063-A200-C0 CCATDB-F2063-A250-C0 CCATDB-F2063-A300-C0 CCATDB-F2063-A350-C0 CCATDB-F2063-A400-C0 CCATDB-F2063-A450-C0 CCATDB-F2063-A500-C0 CCATDB-F2063-A550-C0 CCATDB-F2063-A600-C0 CCATDB-F2063-A650-C0 CCATDB-F2063-A700-C0 CCATDB-F2063-A750-C0 CCATDB-F2063-A800-C0 CCATDB-F2063-A850-C0 CCATDB-F2063-A900-C0 52 with 2 S10TEN modules, and additional cable strain relief S10TEN Solution Package S/FTP 900/23 - 10 S10TEN Solution Package S/FTP 900/23 - 15 S10TEN Solution Package S/FTP 900/23 - 20 S10 TEN Solution Package S/FTP 900/23 - 25 S10TEN Solution Package S/FTP 900/23 - 30 10 m 15 m 20 m 25 m 30 m S10TEN Solution Package S/FTP 900/23 - 35 35 m Solution Package S/FTP 900/23 - 50 50 m S10TEN Solution Package S/FTP 900/23 - 65 65 m S10TEN Solution Package S/FTP 900/23 - 80 80 m S10TEN Solution Package S/FTP 900/23 - 40 S10TEN Solution Package S/FTP 900/23 - 45 S10 TEN S10TEN Solution Package S/FTP 900/23 - 55 S10 TEN Solution Package S/FTP 900/23 - 60 S10TEN Solution Package S/FTP 900/23 - 70 S10TEN Solution Package S/FTP 900/23 - 75 S10TEN Solution Package S/FTP 900/23 - 85 S10TEN Solution Package S/FTP 900/23 - 90 Corning Cable Systems 40 m 45 m 55 m 60 m 70 m 75 m 85 m 90 m FutureCom™ 10 Plug & Play™ Solutions TEN Introduction Application The S10TEN Plug and Play™ Solution has been especially cre- ated for use in data center applications. This special assembly consists of six S/FTP 900/23 cables, with a com- FutureCom F mon FRNC jacket. The cable is pre-terminated with six S10TEN modules at both ends. All modules are equipped with addi- tional cable strain relief, to allow higher pulling force during FutureCom 10TEN installation (the pulling force is restricted by the cable only). They enable rapid Plug and Play installation in data centers and therefore significantly reduce installation time. 100% 6x S/FTP 900/23 cables with common Length FRNC jacket, both ends terminated CCATDB-F2663-A200-C0 CCATDB-F2663-A300-C0 CCATDB-F2663-A400-C0 with 6 S10TEN modules, and additional cable strain relief S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 20 S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 30 S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 40 *Other lengths available upon request. Installation Option 20 m 30 m 40 m S10TEN Plug & Play Solution Package, with 6x S/FTP 900/23 cables with common FRNC jacket, both ends terminated with 6 S10TEN modules, and additional cable strain relief: CCATDB-F2663-A200-C0 installed in a CCHE Empty Panel for 6 LANscape modules Further Information Special Cable CCHE-CP00-LS CCHE Panel with Plug & Play Solution Package Corning Cable Systems FutureCom UD FutureCom UE S10 Plug & Play Solution Package, with TEN Hardware Description Flex Wire Cable Telephone / for Patch Cord ISDN Products Order Number Industrial Cable Ordering Information FutureCom D FutureCom E factory testing reduces failures during installation. 53 FutureCom™ 10 Universal Test Cord for Channel Testing TEN Application The universal channel test cord can be used for acceptance tests of shielded FutureCom 10TEN system in conjunction with the universal test adapter from Fluke or other test device manufactureres. One pair of these test cords is required for acceptance tests. Ordering Information Order Number CCATGB-F10M0-A030-C0 Description Universal Test Cord for the acceptance tests of the FutureCom 10 TEN system in conjunction with the universal test adapter from Fluke or another test device manufacturers, 2xRJ45, 4 pairs, 3 m 54 Corning Cable Systems Units per Delivery 1/1 4.2.3. Cat. 6 F/FTP 450/23 Cable 66 4.3.1. S250 Module Overview 68 4.3. Connecting Hardware 4.3.2. Certificate for S250 Module 69 4.3.3. S250 Module 70 4.3.4. S250fx Module 71 4.4. Hardware 4.4.1. S250 Outlets and Patch Panel 72 4.4.3. Installation Options for Outlets 74 4.5.1. Cat.6 Patch Cords 75 4.4.2. S250 Double Module Outlet 73 4.5. Patch Cords 4.5.2. Consolidation Point Patch Cords 76 4.6. Plug & Play™ 77 79 Special Cable Industrial Cable 4.7. Test Cable FutureCom F 64 FutureCom 10TEN 4.2.2. Cat. 6 S/FTP 450/23 Cable 61 FutureCom E 4.2.1. Cat. 7 S/FTP 900/23 and S/FTP 600/23 Cable FutureCom D 4.2. Cable FutureCom UD FutureCom UE 56 Hardware 4.1. System Descriptions & Data Flex Wire Cable Telephone / for Patch Cord ISDN Products FutureCom E Further Information 4 Introduction Table of contents Corning Cable Systems 55 FutureCom™ E System FutureCom E is Corning’s proven system solution for symmetrical cabling. It exceeds all requirements of the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D and E links and Categories 5 and 6 for components. In addition, the FutureCom E system also satisfies Category 5e according to TIA/EIA-568-A-5. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S250 outlet, 2xRJ45, Cat.6, inclined, CAXESD-S0201-C001 S/FTP flex/26, blue, 2xRJ45 connectors, 4 pairs, for 10/100/1000Base-T CCAEGB-G2002-A020-C0 FutureCom S/FTP 600/23 CCXEDB-F0047-C001-L7 19“ Patch Panel, for max. 24 LANscape® modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001 S250 Module, 1 x RJ45,shielded, Cat. 6 CAXESM-00100-C001 S/FTP flex/26, blue, 2xRJ45- connectors, 4 pairs, for 10/100/1000 Base-T CCAEGB-G2002-A020-C0 A very high level of system performance is achieved for the The system is suitable for all recognized standardized voice cords. The resulting performance and the future security Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T) link through the use of high-quality Category 6 connection technology, Category 6 and 7 cables and Category 6 patch guaranty maximum investment protection. Fully configured with a RJ45 connector and RJ45 module, the cabling can be used universally and is application-neutral. 56 and data transmission procedures. This applies to analog voice transmission, ISDN,Token Ring, Ethernet (10/100Base-T), and for future high bit-rate transmission procedures. The performance of the FutureCom E cabling system has been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in Europe are observed. Corning Cable Systems ACR in dB (typ. FutureCom E values) Min. ELFEXT in dB* ELFEXT in dB (typ. FutureCom E values) Min. return loss in dB* Return loss in dB (typ. FutureCom E values) * According to ISO/IEC 11801 (2002) 61.0 70.6 63.3 73 19.0 22.0 63.0 – 58.5 – 65.0 – 22.0 – 8.0 58.3 – 50.3 – 60.0 – 22.0 – 100 21.7 50.0 46.6 12.5 – 37.5 – 48.0 – 20.0 – 16.5 39.9 18.2 30.0 23.3 46.0 12.0 18.0 155.5 – 20.0 43.7 – 23.7 – 38.8 – 17.0 – 200 – 250 35.9 41.1 38.8 24.0 – 17.1 – 35.0 – 16.0 – 27.0 33.1 FutureCom F Min. ACR in dB* 65.0 5.5 62.5 – – 2.8 11.8 15.3 FutureCom 10TEN 72.2 Min. NEXT in dB* 2.1 20 – 33.3 8.0 15.0 FutureCom E NEXT in dB (typ. FutureCom E values) Attenuation in dB (typ. FutureCom™ E values) 10 – FutureCom D The system values cited only apply to the use of original FutureCom E products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown. Attenuation and Near-end Crosstalk (NEXT) NEXT in dB (typ. FutureCom E values) min. NEXT in dB According to standard max. Attenuation in dB According to standard Attenuation in dB (typ. FutureCom E values) Further Information Special Cable Industrial Cable Frequency in MHz FutureCom UD FutureCom UE 1 4.0 Hardware Max. attenuation in dB* Flex Wire Cable Telephone / for Patch Cord ISDN Products Frequency in MHz Introduction FutureCom™ E System Data for Channel Class E (2002) Corning Cable Systems 57 FutureCom™ E System Data Far-end Crosstalk Relating to the Far End (ELFEXT) ELFEXT in dB (typ. FutureCom™ E values) Min. ELFEXT in dB According to standard Frequency in MHz Return Loss Return loss in dB (typ. FutureCom E values) min. Return loss in dB According to standard Frequency in MHz Test Setup FutureCom E Test Cable, 2xRJ45, 3 m Nominal intrinsic impedance 100 V S250 Patch Panel 19“ Max. delay (according to standard) 0.05 µs S250 Module, 2xRJ45 90 m FutureCom S/FTP900/23 FutureCom E Test Cable, 2 x RJ45, 3 m 58 Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom E values) Max. delay (typ. FutureCom E values) Corning Cable Systems 40 V 18 V , 0.02 µs Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ E Certificate 4-Connector Channel Corning Cable Systems 59 FutureCom™ E Certificate 3-Connector Permanent Link 60 Corning Cable Systems Foil shielding (PiMF) FutureCom cables are low-skew products. This is increas- PE foam-skin insulation suitability of the cable for utilization up to the GHz area enables the highest possible transmission speeds in futureproof networks. These cables have a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP) which guarantees outstanding shielding characteristics. The cable satisfies Class B interference radiation standards (EN 55022) as well as immunity (EN 55024) which enables the realization of CE-compatible networks. The FutureCom S/FTP 900/23 and 600/23 cables are also available in a triplex version. The compact construction allows flat as well as folded installation. Further Information Copper conductor AWG 23 ingly required for applications above 1 Gigabit-Ethernet. The FutureCom UD FutureCom UE tions. Twisted pair Hardware transmission characteristics exceed Category 7 specifica- Flex Wire Cable Telephone / for Patch Cord ISDN Products designed for applications up to 1000/800 MHz and their Industrial Cable The FutureCom™ S/FTP 900/23 and S/FTP 600/23 cables are Halogen-free jacket, flame retardant Special Cable Application Braided shield 4 shielded pairs FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23 Corning Cable Systems 61 FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23 Features S/FTP 900/23 specified up to 1000 MHz, S/FTP 600/23 specified up to 800 MHz Outstanding electrical characteristics Easy and convenient installation on double and triple outlets Compact installation of the triple cable either flat or folded (øonly 16.3 mm) Each pair is individually foil shielded Full braid shield Low skew between the pairs Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Halogen-free Foam-skin material Halogen-free, flame retardant Dry and damp rooms 0 to +50°C Min. bending radius -20 to +60°C >_ 40 mm (for 2 or 3x installation (4x2...) over flat side) Operating temperature for one-time bending Min. bending radius during Copper conductor 62 (4x2...) over flat side) >_ 60 mm (for 2 or 3x AWG 23 Electrical Characteristics (at 20°C) Largest resistance margin Insulation resistance Impedance Zo at 0.064 MHz Impedance Zo at 1 - 100 MHz Impedance Zo at 101 - 250 MHz Impedance Zo at 251 - 600 MHz Surface transfer impedance 1% >5000 mV x km 125 V +/– 20% 100 V +/– 15% 100 V +/– 18% 100 V +/– 25% <10 m V/m at 10 MHz Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz Unbalance to ground dB/BZL = 100 m Unbalance to ground dB/BZL = 100 m Propagation velocity at > 10 MHz (NVP x c) Propagation delay >_ 10 MHz Delay skew Corning Cable Systems >40 dB at 1 MHz >20 dB at 100 MHz 0.79 x c 4.2 ns/m 4 ns/100 m 65.3 60.8 Attenuation in dB/100m * 2.0 Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 Typical values dB/100m 1.7 NEXT in dB at 100 m * 80.0 PSNEXT in dB at 100 m * 77.0 Typical values in dB at 100m 98.0 ELFEXT in dB at 100 m * 80.0 Typical values in dB at 100m 93.0 PSELFEXT in dB at 100 m * 77.0 Typical values in dB at 100m 91.0 5.7 7.2 5.0 6.5 77.0 77.0 98.0 98.0 74.0 69.9 93.0 93.0 71.0 66.9 91.0 91.0 8.1 7.3 80.0 77.0 98.0 68.0 93.0 65.0 91.0 10.1 14.5 9.2 13.2 80.0 75.1 77.0 72.5 98.0 98.0 64.1 58.1 90.0 86.0 61.1 55.1 88.0 84.0 18.5 33.3 16.8 30.0 72.4 69.4 62.3 98.0 94.0 54.0 44.5 83.0 68.0 51.0 41.5 81.0 66.0 48.9 42.5 92.0 57.8 90.0 38.4 51.0 35.4 49.0 900 55.0 – 86.0 – 84.0 – – 1000 59.0 – 83.0 – 81.0 – – – – – – – – ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 31.0 24.0 * Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) Electrical Characteristics (at 20°C) for S/FTP 600/23 1 Frequency in MHz 10 16 20 31.25 62.5 100 Attenuation in dB/100m * 2.0 Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 Typical values dB/100m 5.7 1.7 NEXT in dB at 100 m * 5.0 80.0 PSNEXT in dB at 100 m * 80.0 77.0 Typical values in dB at 100m 77.0 98.0 ELFEXT in dB at 100 m * 98.0 80.0 Typical values in dB at 100m 74.0 93.0 PSELFEXT in dB at 100 m * 93.0 77.0 Typical values in dB at 100m 71.0 91.0 ACR in dB 91.0 98.3 95.0 7.2 6.5 80.0 77.0 98.0 69.9 93.0 66.9 91.0 93.5 8.1 7.3 80.0 77.0 98.0 68.0 93.0 65.0 91.0 92.7 10.1 9.2 80.0 77.0 98.0 64.1 90.0 61.1 88.0 90.8 14.5 18.5 13.2 72.4 72.5 98.0 58.1 86.0 55.1 84.0 86.8 69.4 97.0 54.0 83.0 51.0 81.0 82.1 600 65.3 60.8 33.3 16.8 75.1 300 30.7 95.0 62.3 93.0 44.5 68.0 41.5 66.0 64.3 48.9 44.0 91.0 57.8 89.0 38.4 51.0 35.4 49.0 47.0 800 53.0 – 87.0 – 85.0 – – – – 34.0 – * Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) Ordering Information Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Order Number Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) S/FTP 900/23 4P 7+ S/FTP 900/23 4P S/FTP 900/23 8P S/FTP 900/23 12P S/FTP 600/23 4P S/FTP 600/23 4P S/FTP 600/23 8P S/FTP 600/23 12P 7+ 4 0.63 Yes 154 7.7 7+ 12 1.89 Yes 462 7.7x25.0 195 7+ 7 7 7 7 4 8 4 4 8 12 0.63 1.26 0.63 0.63 1.26 1.89 Yes Yes Yes Yes Yes Yes 154 308 154 154 308 462 7.7 64 64 7.7x16.5 130 7.7 7.7 64 64 7.7x16.5 130 7.7x25.0 195 * X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 1000 CCXEDB-I0047-C001-L7 500 CCXEDB-I0127-C001-L6 250 500 1000 250 500 500 CCXEDB-I0047-C001-X2* CCXEDB-I0087-C001-L6 CCXEDB-F0047-C001-L7 CCXEDB-F0047-C001-X2* CCXEDB-F0087-C001-L6 CCXEDB-F0127-C001-L6 63 FutureCom F 600 FutureCom 10TEN 300 FutureCom E 100 FutureCom D 62.5 FutureCom UD FutureCom UE 80.0 31.25 Hardware 80.0 20 Flex Wire Cable Telephone / for Patch Cord ISDN Products 16 Industrial Cable 10 Special Cable 1 Frequency in MHz Further Information Electrical Characteristics (at 20°C) for S/FTP 900/23 Introduction FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23 FutureCom™ E Cat. 6 Cables S/FTP 450/23 Braided shield Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Copper conductor AWG 23 Application The FutureCom™ S/FTP 450/23 cables are designed for applications of up to 600 MHz and their transmission characteristics exceed Category 6 specifications. FutureCom cables are low-skew products, i.e. the skew between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees outstanding shielding characteristics. The cables satisfies Class B interference radiation standards (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Halogen-free Foam-skin material Halogen-free, flame retardant Dry and damp rooms 0 to +50°C Full braid shield Streamlined design Lightweight Low skew between the pairs Low smoke according to IEC 61034 (4x2...) over flat side) 64 Each pair is shielded (PiMF) >_ 60 mm (for 2 x installation Copper conductor Outstanding electrical characteristics Halogen-free (LSZH) >_ 40 mm (for 2 x Min. bending radius during S/FTP 450/23, specified up to 600 MHz -20 to +60°C Min. bending radius for one-time bending Features (4x2...) over flat side) AWG 23 Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Corning Cable Systems Electrical Characteristics (at 20°C) Largest resistance margin Introduction FutureCom™ E Cat. 6 Cables S/FTP 450/23 1% Insulation resistance >5000 MV x km Impedance Zo at 0.064 MHz 125 V +/– 20% Impedance Zo at 1 - 100 MHz 100 V +/– 18% Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz Surface transfer impedance FutureCom F 100 V +/– 15% Impedance Zo at 101 - 250 MHz <10 mV/m at 10 MHz / S/FTP Unbalance to ground dB/BZL = 1000 m Unbalance to ground dB/BZL = 100 m FutureCom 10TEN >46 dB at 64 kHz >20 dB at 100 MHz Propagation velocity at > 10 MHz (NVP x c) Propagation delay >_ 10 MHz 0.79 x c FutureCom E 4.2 ns/m Delay skew 20 31.25 62.5 100 Attenuation in dB/100m * 2.1 Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 97.0 Typical values dB/100m 6.0 1.8 NEXT in dB at 100 m * 5.3 66.0 PSNEXT in dB at 100 m * 59.3 64.0 Typical values in dB at 100m 57.3 98.0 ELFEXT in dB at 100 m * 98.0 66.0 Typical values in dB at 100m 50 93.0 PSELFEXT in dB at 100 m * 93.0 64.0 Typical values in dB at 100m 47 91.0 ACR in dB 91.0 98.2 94.7 7.6 6.8 56.2 54.2 98.0 45.9 93.0 41.0 91.0 93.2 8.5 7.6 54.8 52.8 98.0 44.0 93.0 41.0 91.0 92.4 10.8 9.6 51.9 49.9 98.0 40.1 90.0 37.1 88.0 90.4 15.5 13.6 47.4 45.4 95.0 34.1 86.0 31.1 84.0 83.4 250 19.9 33.0 95.0 90.0 17.3 44.3 42.3 93.0 30.0 83.0 27.0 81.0 77.7 27.7 38.3 36.3 88.0 22.0 70.0 19.0 68.0 62.3 450 38.0 – 85.0 – 83.0 – 54.0 – 52.0 – 47.0 600 44.8 – 75.0 – 73.0 – 48.0 – 46.0 – 30.2 * Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1) Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Order Number Strength(N) (mm) (kg/km) (m) S/FTP 450/23 4P 6 S/FTP 450/23 4P S/FTP 450/23 8P 6 6 4 4 8 0.57 0.57 1.14 Yes Yes Yes 145 145 290 7.9 7.9 55 55 7.5x16.6 120 * X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 1000 250 500 Industrial Cable Ordering Information FutureCom UD FutureCom UE 16 Hardware 10 Flex Wire Flex Wire CableCable Telephone / for Patch for Patch Cord Cord ISDN Products 1 CCXEDB-D0047-C001-L7 CCXEDB-D0047-C001-X2* CCXEDB-D0087-C001-L6 65 Special Cable Frequency in MHz Further Information Electrical Characteristics (at 20°C) FutureCom D 4 ns/100 m FutureCom™ E Cat. 6 Cables F/FTP 450/23 Foil shield (FTP) Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs Additional wire PE foam-skin insulation Copper conductor AWG 23 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Halogen-free Foam-skin material Halogen-free, flame retardant Dry and damp rooms 0 to +50°C FutureCom cables are low-skew products, i.e. the skew between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are additionally foil shielded (F/FTP), which guarantees out- standing shielding characteristics. The cables satisfies Class B interference radiation standards (EN 55022), as well as im- munity (EN 55024), which enables the realization of CE-compatible networks. Features F/FTP flex cable, specified up to 450 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full foil shielding and additional copper wire Streamlined design Lightweight Low skew between the pairs Low smoke according to IEC 61034 (4x2...) over flat side) 66 characteristics exceed Category 6 specifications. >_ 60 mm (for 2 x installation Copper conductor applications of up to 450 MHz and their transmission Halogen-free (LSZH) >_ 40 mm (for 2 x Min. bending radius during The FutureCom™ F/FTP 450/23 cables are designed for -20 to +60°C Min. bending radius for one-time bending Application (4x2...) over flat side) AWG 23 Fire retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Corning Cable Systems Electrical Characteristics (at 20°C) Largest resistance margin Introduction FutureCom™ E Cat. 6 Cables F/FTP 450/23 2% Insulation resistance >5000 MV x km Impedance Zo at 0.064 MHz 125 V +/– 20% Impedance Zo at 1 - 100 MHz 100 V +/– 18% Unbalance to ground dB/BZL = 100 m >40 dB at 1 MHz Surface transfer impedance FutureCom F 100 V +/– 15% Impedance Zo at 101 - 250 MHz 100 mV/m at 10 MHz Unbalance to ground dB/BZL = 1000 m Unbalance to ground dB/BZL = 100 m FutureCom 10TEN >46 dB at 64 kHz >20 dB at 100 MHz Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 0.79 x c FutureCom E 4.3 ns/m Delay skew 20 59.3 56.2 54.8 31.25 62.5 100 250 51.9 47.4 44.3 38.3 Attenuation in dB/100m * 2.1 Typical values in dB at 100 m >100.0 >100.0 >100.0 >100.0 >100.0 97.0 Typical values dB/100m 1.8 NEXT in dB at 100 m * 66.0 PSNEXT in dB at 100 m * 64.0 Typical values in dB at 100m 98.0 ELFEXT in dB at 100 m * 66.0 Typical values in dB at 100m 93.0 PSELFEXT in dB at 100 m * 64.0 Typical values in dB at 100m 91.0 ACR in dB 98.2 6.0 5.3 57.3 98.0 50 93.0 47 91.0 94.7 7.6 6.8 54.2 98.0 45.9 93.0 41.0 91.0 93.2 8.5 7.6 52.8 98.0 44.0 93.0 41.0 91.0 92.4 10.8 9.6 49.9 98.0 40.1 90.0 37.1 88.0 90.4 15.5 13.6 45.4 95.0 34.1 86.0 31.1 84.0 83.4 19.9 17.3 95.0 42.3 93.0 30.0 83.0 27.0 81.0 77.7 33.0 27.7 90.0 36.3 88.0 22.0 70.0 19.0 68.0 62.3 450 38.0 – 85.0 – 83.0 – 54.0 – 52.0 – 47.0 * Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1) Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Order Number Strength(N) (mm) (kg/km) (m) F/FTP 450/23 4P 6 F/FTP 450/23 4P F/FTP 450/23 8P 6 6 4 4 8 0.57 0.57 1.16 Yes Yes Yes 105 105 210 7.4 7.4 50 50 7.4x15.5 100 * X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 1000 250 500 Industrial Cable Ordering Information FutureCom UD FutureCom UE 16 Hardware 10 Flex Wire Cable Telephone / for Patch Cord ISDN Products 1 CCXDDA-D0047-C001-L7 CCXDDA-D0047-C001-X2* CCXDDA-D0087-C001-L6 67 Special Cable Frequency in MHz Further Information Electrical Characteristics (at 20°C) FutureCom D 4 ns/100 m FutureCom™ E Module Overview Features Fully compatible with all modular LANscape® systems Wide range of installation options Few individual components High-level component density Individual shielding Halogen-free Fire class UL94V-0 Optimized construction with printed circuit board for bandwidths of more than 300 MHz 1500 connector cycles are possible Proven IDC technology for wires with AWG 24 to AWG 22 Module reusable several times Individual Components of the S250 Module Disassembled S250 Basic Module Features Wire management using TIA/EIA 568 A/B coding Installation in pairs (no untwisting of the pairs necessary) Rapid assembly time Easy handling Compatible with all FutureCom™ S/FTP and F/FTP cables Wire Management 68 Corning Cable Systems Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ E Certificate Cat.6 De-embedded for S250 Modules Corning Cable Systems 69 FutureCom™ E S250 Module Features Easy and quick to install, no special tools required IDC connection (IDC = Insulation Displacement Contacts) High-level component density Universal usage in all modular LANscape® and FutureCom™ components Category 6 (2002), de-embedded Ordering Information Order Number CAXESM-00100-C001 Description S250 Module, 1xRJ45, shielded, Cat.6, incl. copper conducting tape for installation in LANscape modular patch panels, Unit per Delivery 1/1 outlets and floor box solutions CAXESM-00200-C001 S250 Double Module, 2xRJ45, shielded, Cat.6, incl. copper conducting tape for installation in LANscape modular patch panels, 1/1 outlets and floor box solutions Cable Strain Relief Using the additional cable strain relief allows increased pulling force on the module housings. Order Number CAXCSN-00000-C001 Description Additional cable strain relief, for higher pulling force on shielded FutureCom modules for solid wire, and for assembly of flexible consolidation point cables with FutureCom S10TEN fx, S250fx or U250fx modules 70 Corning Cable Systems Unit per Delivery 100/1 FutureCom™ E S250fx Module Introduction Application S250fx Modules are used for the assembly of flexible cables or consolidation point cables. FutureCom F Features Fully compatible with all modular LANscape® connecting Individual shielding Proven IDC technology for AWG 24 and AWG 26 stranded Individual components of the S250fx Module 1500 connector cycles are possible Wire management using A/B printing according to TIA/EIA 568 Installation in pairs (no untwisting of the pairs is necessary) Category 6, de-embedded FutureCom UD FutureCom UE Easy handling and very short assembly time Requirements for Consolidation Points For the assembly of modules with flexible cables, an additional cable strain relief must be used CCS patch cords (with RJ45 connectors) are wired according to TIA/EIA 568 B; when using other single- ended pre-terminated connecting cables they should be Ordering Information S250fx Module, 1xRJ45, shielded, Cat.6, especially suitable for consolidation point cable with AWG 24/26 stranded wires, Unit per Delivery 1/1 incl. copper conducting tape and Special Cable CAXESM-00100-C003 Description additional cable strain relief for installation in LANscape hardware Further Information Order Number attenuation specification than the flexible cable Industrial Cable Assembled S250fx Module with Additional Cable Strain Relief wired according to the RJ45 connector scheme The installed solid wire cable should have a lower Hardware Module reusable several times Flex Wire Cable Telephone / for Patch Cord ISDN Products wires FutureCom D Wide range of installation options FutureCom E FutureCom 10TEN hardware Corning Cable Systems 71 FutureCom™ E S250 Outlets and Patch Panel Ordering Information S250 Outlets Order Number Description S250 Outlet, 2xRJ45, shielded, Cat. 6, inclined, Unit per Delivery incl. mounting frame with grounding flaps, central plate 50x50 mm with designation window, screw-fixed, copper CAXESD-S0201-C001 CAXESD-S0202-C001 S250 Patch Panel Order Number CAXESV-02400-C001 conducting tape (without face plate) white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Description Unit per Delivery S250 Patch Panel 19“, shielded, Cat. 6, including 24 FutureCom S250 1/1 modules and copper conducting tape, with integrated cable strain relief, 1 U, high-grade steel front panel Patch panel accessories please see page 156. 72 Corning Cable Systems Order Number CAXESD-S0200-C001 Description S250 Double Module Outlet, 2xRJ45, Cat. 6, inclined, incl. mounting frame with Unit per Delivery 1/1 FutureCom F Ordering Information Introduction FutureCom™ E S250 Double Module Outlet grounding flaps and FutureCom 10TEN copper conducting tape (suitable for Rutenbeck- compatible central plates FutureCom UD FutureCom UE FutureCom D FutureCom E or faceplates) Installation Option S250 Double Module Outlet, 2xRJ45, Cat. 6, inclined, incl. mounting frame and copper conducting tape. Hardware CAXESD-S0200-C001 For example, mounted with a high grade steel face plate Further Information Special Cable S250 Double Module Outlet with face plate (Jung) Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products from Jung Corning Cable Systems 73 FutureCom™ E Outlet Installation Options Option 1: 6-Port Frame Set for the installation of 6 LANscape® fiber optic or FutureCom™ modules, inclined, in- cluding mounting frame and two triple housings with designation window and dust protection flaps as well as 151x80 mm face plate, white, RAL 9010: WAXWSE-V0601-C001 equipped with two S250 modules CAXESM-00100-C001 two black labeling icons WAXWSE-00008-C001 four blue labeling icons WAXWSE-00004-C001 6-Port Frame Set, inclined and two blue S/FTP flex/26 Patch Cords CCAEGB-D2002-A030-C0 Option 2: S250 Inclined Outlet with two S250 Modules, white, RAL 9010 in the race-way: CAXESD-S0201-C001 equipped with one black labeling icon WAXWSE-00008-C001 and one blue labeling icon WAXWSE-00004-C001 Built into a Tehalit race-way S250 Inclined Outlet with two S250 Modules Option 3: Double Surface Outlet for the mounting of 2 LAN- scape modules, inclined, including face plate and double housing with designation window and dust protection flaps, white, RAL 9010: WAXWSE-V0201-C001 equipped with two S250 modules CAXESM-00100-C001 one gray labeling icon WAXWSE-00003-C001 one green labeling icon WAXWSE-00006-C001 and one green S/FTP flex/26 Patch Cord 2-Port Surface Mount Outlet CCAEGB-D4002-A020-C0 using one surface mount housing WAXWSE-00001-C003 ... and one “DELTAfläche” face plate 74 Corning Cable Systems FutureCom™ E Cat. 6 Patch Cords RJ45 to RJ45 Introduction Description The FutureCom E System patch cords consist of Category 6 flex cable with shielded RJ45 connectors at both ends. The flex cables have four individual foil-shielded pairs and full FutureCom F braid copper shielding. The zero halogen patch cords (LSZH) are non-corrosive (according to IEC 60754-2), low smoke (according to IEC 61034) and flame retardant (according to FutureCom 10TEN IEC 60332-1, Category B). They are available in various lengths and colors. FutureCom E Features FutureCom D S/FTP flex cable, specified up to 600 MHz Application-neutral due to using all four pairs Minimum surface transfer impedance (<10 mV/m at 10 MHz) FutureCom UD FutureCom UE Outstanding transmission characteristics according to Channel E (2002) 1 2 3 4 5 6 = = = = = = gray blue yellow green red black 2 2 - C0 Select length. 010 015 020 030 040 050 060 075 080 100 150 200 250 300 = = = = = = = = = = = = = = 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters 20 meters (gray only) 25 meters (gray only) 30 meters (gray only) Corning Cable Systems Industrial Cable Select color. 002 - A Special Cable 1 1 Further Information CCAEGB - G Flex Wire Cable Telephone / for Patch Cord ISDN Products Ordering Information Hardware Cat. 6 75 FutureCom™ E Consolidation Point Patch Cords Description The FutureCom™ E Consolidation Point Patch Cords are factory terminated cable assemblies with one S250 fx module and one RJ45 connector. FutureCom S/FTP flex/26 Cable is specified up to 600 MHz and satisfies Category 7 transmission characteristics. The CP Patch Cords are suitable to connect LANscape® Consolidation Point Housings to wall or desktop outlets. Ordering Information Order Number Description S/FTP flex/26 Patch Cords, 4 pairs, application-neutral, FRNC sheath, Length gray, pre-terminated with one RJ45 CCAEGB-D1052-A050-C0 CCAEGB-D1052-A100-C0 CCAEGB-D1052-A150-C0 CCAEGB-D1052-A200-C0 Other lengths upon request 76 connector and one S250fx module, Cat. 6, for example 10/100/1000Base-T CP Patch Cords S/FTP flex/26 - 5 CP Patch Cords S/FTP flex/26 - 10 CP Patch Cords S/FTP flex/26 - 15 CP Patch Cords S/FTP flex/26 - 20 Corning Cable Systems 5m 10 m 15 m 20 m FutureCom™ E Plug & Play™ Solutions Introduction Application The S250 Solution Packages are pre-terminated cables with S250 modules at both ends. They are generally offered with FutureCom F FutureCom™ S/FTP 900/23 cables. Both modules are equipped with additional cable strain relief, to allow higher pulling forces during insertion (the pulling force is restricted FutureCom 10TEN by the cable only). They enable Plug and Play™ installation CCAEDB-D2050-A250-C0 CCAEDB-D2050-A300-C0 CCAEDB-D2050-A350-C0 CCAEDB-D2050-A400-C0 CCAEDB-D2050-A450-C0 CCAEDB-D2050-A500-C0 CCAEDB-D2050-A550-C0 CCAEDB-D2050-A600-C0 CCAEDB-D2050-A650-C0 CCAEDB-D2050-A700-C0 CCAEDB-D2050-A750-C0 CCAEDB-D2050-A800-C0 CCAEDB-D2050-A850-C0 CCAEDB-D2050-A900-C0 with 2 S250 modules and additional cable strain relief S250 Solution Package S/FTP 900/23 - 10 10 m S250 Solution Package S/FTP 900/23 - 25 25 m S250 Solution Package S/FTP 900/23 - 15 S250 Solution Package S/FTP 900/23 - 20 S250 Solution Package S/FTP 900/23 - 30 S250 Solution Package S/FTP 900/23 - 35 15 m 20 m 30 m 35 m S250 Solution Package S/FTP 900/23 - 40 40 m S250 Solution Package S/FTP 900/23 - 55 55 m S250 Solution Package S/FTP 900/23 - 70 70 m S250 Solution Package S/FTP 900/23 - 45 S250 Solution Package S/FTP 900/23 - 50 S250 Solution Package S/FTP 900/23 - 60 S250 Solution Package S/FTP 900/23 - 65 S250 Solution Package S/FTP 900/23 - 75 S250 Solution Package S/FTP 900/23 - 80 S250 Solution Package S/FTP 900/23 - 85 S250 Solution Package S/FTP 900/23 - 90 45 m 50 m 60 m 65 m 75 m 80 m 85 m 90 m Hardware CCAEDB-D2050-A200-C0 4 pairs, FRNC jacket pre-terminated Flex Wire Cable Telephone / for Patch Cord ISDN Products CCAEDB-D2050-A150-C0 Solution Package, S/FTP900/23 cable, Length Industrial Cable CCAEDB-D2050-A100-C0 Description Further Information Order Number Special Cable Ordering Information FutureCom UD FutureCom UE FutureCom D FutureCom E and therefore significantly reduce installation time. Corning Cable Systems 77 FutureCom™ E Plug & Play™ Solutions Application The S250 Plug and Play™ Solution has been especially created for use in data center applications. This special assembly consists of six S/FTP 900/23 cables, with a com- mon FRNC jacket. The cable is pre-terminated with six S250 modules at both ends. All modules are equipped with addi- tional cable strain relief, to allow higher pulling force during installation (the pulling force is restricted by the cable only). They enable rapid Plug and Play installation in data centers and therefore significantly reduce installation time. 100% factory testing reduces failures during installation. Ordering Information Order Number Description S250 Plug & Play Solution Package, with 6x S/FTP 900/23 cables with common Length FRNC jacket, both ends terminated CCAEDB-D2650-A200-C0 CCAEDB-D2650-A300-C0 CCAEDB-D2650-A400-C0 with 6 S250 modules, and additional cable strain relief S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 20 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 30 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 40 Other lengths available upon request. Installation Option 20 m 30 m 40 m S250 Plug & Play Solution Package, with 6x S/FTP 900/23 cables with common FRNC jacket, both ends terminated with 6 S250 modules, and additional cable strain relief: CCAEDB-D2650-A200-C0 installed in a CCHE Empty Panel for 6 LANscape modules CCHE-CP00-LS CCHE Panel with Plug & Play Solution Package 78 Corning Cable Systems FutureCom™ E Universal Test Cord for Channel Testing Introduction Application The universal channel test cord can be used for acceptance tests of shielded FutureCom™ E Systems in conjunction with the universal test adapter from Fluke or other test device FutureCom F manufactureres. of the FutureCom E System in conjunction with the universal test adapter from Fluke FutureCom E Universal Test Cord, for the acceptance test Units per Delivery 1/1 or other test device manufacturers, Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE 2xRJ45, 4 pairs, 3 m Special Cable CCAEGB-D10M0-A030-C0 Description Further Information Order Number FutureCom D Ordering Information FutureCom 10TEN One pair of these test cords is required for acceptance tests. Corning Cable Systems 79 80 Corning Cable Systems 5.3.1. Cat. 5 SF/UTP 300/24 FRNC/PVC Cable 86 5.3.3. Cat. 5 F/UTP 300/24 FRNC/PVC Cable 90 5.4.1. S100e Module Overview 92 5.3.2. Cat. 5 SF/UTP 300/24 FRNC, 16P Cable 5.4. Connecting Hardware 5.4.2. S100e and S100eL Module 88 93 5.5. Hardware 5.5.1. S100e Outlets and Patch Panels 94 5.5.3. S100eL Outlets and Patch Panels 96 5.5.2. S100e Double Module Outlet 95 5.5.4. Installation Options for Outlets 97 5.6. Patch Cords 98 99 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products 5.7. Plug & Play™ FutureCom F 5.3. Cable FutureCom 10TEN 85 FutureCom E 5.2. Certificates FutureCom D 82 FutureCom UD FutureCom UE 5.1. System Descriptions & Data Hardware FutureCom D Further Information 5 Introduction Table of contents Corning Cable Systems 81 FutureCom™ D System FutureCom D (2002) is Corning’s Class D system solution for symmetrical cabling. It fulfils all requirements of the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D for links and Category 5 for the components. In addition, the FutureCom D system also satisfies Category 5e according to TIA/EIA-568-A-5. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S100e outlet, 2xRJ45, Cat.5, inclined, CAXDSD-S0201-C001 SF/UTP flex/26, green, 2xRJ45 connectors, 4 pairs, for 10/100/1000Base-T CCADGF-D4002-A030-C0 FutureCom SF/UTP 300/24 Cable CCXDEF-I0047-C001-L7 19“ Patch Panel, for max. 24 LANscape® modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001 S100e Module, 1xRJ45, shielded, Cat. 5 CAXDSM-00100-C001 SF/UTP flex/26, green, 2xRJ45- connectors, 4 pairs, for 10/100/1000 Base-T CCADGF-D4002-A020-C0 A high level of system performace is achieved for the entire FutureCom D cabling that conforms to the standards is mace, and future security, guarantees a high degree of mission, ISDN, Token Ring, Ethernet (10-Base-T), Ethernet link through the use of high-quality Category 5 connection technology, cables and patch cords. The resulting perforinvestment protection for the cabling. Fully configured with RJ45 connectors and RJ45 modules, the cabling is application-neutral and can be used universally. 82 suitable for all recognized standardized voice and data transmission procedures. This applies to analog voice trans(100Base-TX) and Gigabit Ethernet (1000Base-T). The performance of the FutureCom D cabling system has been certified by an independent test body (see certificate). Of course, all standardized EMC threshold values in Europe are observed. Corning Cable Systems ACR in dB (typ. FutureCom D values) Min. ELFEXT in dB* ELFEXT in dB (typ. FutureCom D values) Min. return loss in dB* Return loss in dB (typ. FutureCom D values) * According to ISO/IEC 11801 (2002) 70.0 56.0 67.7 57.4 70.0 17.0 19.0 60.0 – 56.5 – 60.0 – 20.0 – 55.0 – 49.2 – 52.0 – 20.0 – 43.6 51.0 34.5 44.0 33.3 48.0 17.0 20.0 8.5 – 48.0 – 39.2 – 46.0 – 19.5 – 10.0 – 44.0 – 34.0 – 43.0 – 19.0 – 62.5 16.0 – 38.0 – 22.0 – 38.0 – 17.0 – 100 24.0 19.0 30.1 36.0 6.1 17.0 17.4 34.0 10.0 13.0 The system values cited are only valid with regard to the use of original FutureCom D products. Derived values, such as PSACR, PSNEXT and PSELFEXT, maintain the required standard values but are not shown for clarity of presentation. Attenuation and Near-end Crosstalk (NEXT) NEXT in dB (typ. FutureCom D values) min. NEXT in dB According to standard max. Attenuation in dB According to standard Attenuation in dB (typ. FutureCom D values) Further Information Special Cable Industrial Cable Frequency in MHz FutureCom F Min. ACR in dB* 60.0 7.0 9.1 31.25 FutureCom 10TEN NEXT in dB (typ. FutureCom D values) 5.8 – 20 FutureCom E Min. NEXT in dB* 3.5 – 16 FutureCom D 2.3 4.0 10 FutureCom UD FutureCom UE Attenuation in dB (typ. FutureCom™ D values) Max. attenuation in dB* 4 Hardware 1 Flex Wire Cable Telephone / for Patch Cord ISDN Products Frequency in MHz Introduction FutureCom™ D System Data for Channel Class D (2002) Corning Cable Systems 83 FutureCom™ D System Data Far-end Crosstalk Relating to the Far End (ELFEXT) ELFEXT in dB (typ. FutureCom™ D values) Min. ELFEXT in dB According to Norm Frequency in MHz Return Loss Return loss in dB (typ. FutureCom D values) min. return loss in dB according to standard Frequency in MHz Test Setup FutureCom™ D SF/UTP flex/26 Connecting Cable, 3 m S100e Modules, 2xRJ45 90 m FutureCom SF/UTP300/24 S100e Patch Panel 19“ FutureCom D SF/UTP flex/26 Patch Cord, 3 m 84 Nominal intrinsic impedance 100 V Max. delay (according to standard) 0.05 µs Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom D values) Max. delay (typ. FutureCom D values) Corning Cable Systems 40 V 18 V , 0.02 µs Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ D Certificates Corning Cable Systems 85 FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC or PVC Braided shield Halogen-free jacket, flame retardant or PVC Twisted pair Foil shielding 4 shielded pairs PE foam-skin insulation Copper conductor AWG 24 Application The FutureCom SF/UTP 300/24 cable is designed for applications of up to 300 MHz and its transmission characteristics exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5) specifications. FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for Gigabit-Ethernet. The cable has a streamlined construction and low weight. The four stranded pairs are sheathed with a foil shield (F/UTP) and, additionally, with a braided shield (SF/UTP), which guarantee outstanding shielding characteristics. The cable satisfies the standard for Class B interference radiation Color Coding Pair 1 Pair 2 Pair 3 Pair 4 (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. white with blue rings/blue white with orange rings/orange white with green rings/green white with brown rings/brown Features SF/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics Full braid copper shield Streamlined design Lightweight Low skew between the pairs Halogen-free (LSZH) jacket Flame retardant according to IEC 60332-3, Category C PVC jacket, flame retardant, according to IEC 60332-1, Category B FRNC is non-corrosive according to IEC 60754-2 86 Corning Cable Systems damp rooms Unbalance to ground dB/BZL = 100 m Min. bending radius >_ 35 mm (for 2 x installation (4x2...) over flat side) Unbalance to ground dB/BZL = 100 m Propagation velocity (4x2...) over flat side) at >10 MHz (NVP x c) Propagation delay >_ 10 MHz >_ 50 mm (for 2 x Electrical Characteristics (at 20°C) 1 Frequency in MHz 10 16 50.3 47.2 Attenuation in dB/100m * 2.1 6.3 Typical values in dB at 100m 77.0 62.0 Typical values dB/100m 2.0 NEXT in dB at 100 m* 65.3 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 75.0 ELFEXT in dB at 100 m * 63.8 Typical values in dB at 100m 72.0 PSELFEXT in dB at 100 m * 60.8 Typical values in dB at 100m 70.0 ACR in dB 75.0 5.6 47.3 60.0 43.8 60.0 40.8 58.0 56.4 20 >20 dB at 100 MHz 0.74 x c 4.5 ns/m Delay skew AWG 24 Copper conductor >40 dB at 1 MHz 7 ns/100 m 31.25 62.5 100 8.0 9.0 11.4 16.5 21.3 59.0 57.0 54.0 50.0 46.0 7.2 44.2 57.0 39.7 54.0 36.7 52.0 51.8 8.0 45.8 42.8 55.0 37.8 52.0 34.8 50.0 49.0 10.1 42.9 39.9 52.0 33.9 48.0 30.9 46.0 43.9 14.4 38.4 35.4 48.0 27.9 40.0 24.9 38.0 35.6 18.2 35.3 32.3 44.0 23.8 34.0 20.8 32.0 27.8 250 29.5 – 38.5 – 36.5 – 22.1 – 20.1 – 9.0 * Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1) Ordering Information Type designation Category No. of Pairs SF/UTP 300/24 4P 5e (FRNC) 4 SF/UTP 300/24 4P SF/UTP 300/24 8P SF/UTP 300/24 4P SF/UTP 300/24 4P SF/UTP 300/24 8P 5e (FRNC) 5e (FRNC) 5e (PVC) 5e (PVC) 5e (PVC) 4 8 4 4 8 Max. Outer [ Weight Length Fire Load Halogen- Tensile (kg/km) (m) Order Number Strength(N) (mm) (MJ/m) free 0.46 FutureCom D -20 to +60°C Min. bending radius during at 10 MHz Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz 0 to +50°C for one-time bending <10 m V/m 300 32.2 – 35.0 – 33.0 – 17.0 – 15.0 – 2.8 0.46 Yes 82 6.1 50 1000 CCXDEF-C0047-C001-L7 0.41 No 82 5.8 45 1000 CCXDLF-C0047-C001-L7 0.96 0.41 0.94 Yes Yes No No 82 164 82 164 6.1 50 6.2x13.5 100 5.8 45 6.2x13.5 97 * X1 cables are delivered in a Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 305 1000 305 1000 FutureCom F Dry and Operating temperature 100 V +/– 15% Surface transfer impedance FutureCom 10TEN Impedance Zo at 1 - 100 MHz flame retardant Temperature range (installation) 125 V +/– 20% FutureCom E Halogen-free, Area/range of application >5000 MV x km Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Foam-skin Hardware Sheath material 1% Insulation resistance CCXDEF-C0047-C001-X1* CCXDEF-C0087-C001-L7 CCXDLF-C0047-C001-X1* CCXDLF-C0087-C001-L7 87 Flex Wire Cable Telephone / for Patch Cord ISDN Products Largest resistance margin FRNC: Halogen-free Industrial Cable PE Foam skin Special Cable PVC: Conductor insulation Electrical Characteristics (at 20°C) Further Information Mechanical Characteristics Introduction FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC or PVC FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC, 16P Halogen-free external jacket, flame retardant Foil Halogen-free jacket, flame retardant Braided shield Foil shielding Metal-free central element Twisted pair 4 shielded pairs Foam-skin PE insulation Copper conductor AWG 24 Application The FutureCom™ SF/UTP 300/24 16P cable is specified for applications up to 300 MHz and its transmission characteristics exeed Category 5 (2002) and Category 5e (TIA/EIA 568-A-5). FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for Gigabit-Ethernet. The four stranded pairs are foil shielded (F/UTP) additionally with a braided shield (SF/UTP), which guarantees outstand- ing shielding characteristics. The cable satisfies the standard for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CEcompatible networks. The Quattro configuration with a shared external sheath for the FutureCom SF/UTP 300/24 16P cable, allows increased mechanical load and enables Color Coding Pair 1 Pair 2 Pair 3 Pair 4 cost-optimized installation. white with blue rings/blue white with orange rings/orange white with green rings/green white with brown rings/brown Features SF/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics Stranded pairs with foil shield and full braid shield. The 4 cable cores are twisted around a non-metallic central element Low skew between the pairs Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 88 Corning Cable Systems Min. bending radius for one-time bending Min. bending radius during 0 to +50°C at 10 MHz Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz -20 to +60°C Unbalance to ground dB/BZL = 100 m >_ 85 mm Unbalance to ground dB/BZL = 100 m Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz AWG 24 Copper conductor <10 m V/m 1 Frequency in MHz 10 16 50.3 47.2 Attenuation in dB/100m * 2.1 6.3 Typical values in dB at 100m 77.0 62.0 Typical values dB/100m 2.0 NEXT in dB at 100 m* 65.3 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 75.0 ELFEXT in dB at 100 m * 63.8 Typical values in dB at 100m 72.0 PSELFEXT in dB at 100 m * 60.8 Typical values in dB at 100m 70.0 ACR in dB 75.0 5.6 47.3 60.0 43.8 60.0 40.8 58.0 56.4 20 >20 dB at 100 MHz 0.74 x c 4.5 ns/m Delay skew Electrical Characteristics (at 20°C) >40 dB at 1 MHz 7 ns/100 m 31.25 62.5 100 8.0 9.0 11.4 16.5 21.3 59.0 57.0 54.0 50.0 46.0 7.2 44.2 57.0 39.7 54.0 36.7 52.0 51.8 8.0 45.8 42.8 55.0 37.8 52.0 34.8 50.0 49.0 10.1 42.9 39.9 52.0 33.9 48.0 30.9 46.0 43.9 14.4 38.4 35.4 48.0 27.9 40.0 24.9 38.0 35.6 18.2 35.3 32.3 44.0 23.8 34.0 20.8 32.0 27.8 250 29.5 – 38.5 – 36.5 – 22.1 – 20.1 – 9.0 * Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1) 300 32.2 – 35.0 – 33.0 – 17.0 – 15.0 – 2.8 SF/UTP 300/24 16P Industrial Cable Ordering Information Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number 5e 16 4.04 Yes 328 16.5 Corning Cable Systems 280 1000 FutureCom F damp rooms >_ 120 mm installation 100 V +/– 15% Surface transfer impedance FutureCom 10TEN Operating temperature Impedance Zo at 1 - 100 MHz Dry and FutureCom D Temperature range (installation) 125 V +/– 20% FutureCom E flame retardant Area/range of application >5000 MV x km Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Halogen-free, Outer jacket 1% Insulation resistance Hardware Largest resistance margin Foam-skin material Flex Wire Cable Telephone / for Patch Cord ISDN Products Halogen-free CCXDEF-C0167-C001-L7 89 Special Cable Conductor insulation Electrical Characteristics (at 20°C) Further Information Mechanical Characteristics Introduction FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC, 16P FutureCom™ D Cat. 5 Cable F/UTP 300/24 FRNC or PVC Foil shielding PVC or halogen-free jacket, flame retardant Twisted pair Foil shielding Additional wire PE foam-skin insulation Copper conductor AWG 24 4 shielded pairs Color Coding white with blue rings/blue Pair 4 white with orange rings/orange Pair 3 The FutureCom™ F/UTP 300/24 Cable is designed for applications of up to 300 MHz and its transmission characteristics exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5) specifications. FutureCom cables are low-skew products, i.e. the skew be- tween the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. The cable has a streamlined construction and low weight. The four stranded pairs are foil shielded (F/UTP). The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunitiy (EN 55024), which enables the realization of CE-compatible networks. Pair 1 Pair 2 Application white with orange rings/orange white with orange rings/orange Features F/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics Full shielding with 2 foils and additional copper wire Streamlined design Lightweight Low skew between the pairs Halogen-free (LSZH) jacket Flame retardant according to IEC 60332-3, Category C PVC jacket, flame retardant according to IEC 60332-1, Category B Non-corrosive according to IEC 60754-2 (FRNC) 90 Corning Cable Systems >_ 50 mm (for 2x installation (4x2...) over flat side) Copper conductor AWG 24 Electrical Characteristics (at 20°C) at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 10 16 50.3 47.3 Attenuation in dB/100m * 2.1 6.3 Typical values in dB at 100m 77.0 62.0 Typical values dB/100m 2.0 NEXT in dB at 100 m* 5.6 65.3 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 47.3 75.0 ELFEXT in dB at 100 m * 60.0 63.8 Typical values in dB at 100m 43.8 72.0 PSELFEXT in dB at 100 m * 60.0 60.8 Typical values in dB at 100m 40.8 70.0 ACR in dB 58.0 20 0.74 x c 4.5 ns/m Delay skew 1 Frequency in MHz >20 dB at 100 MHz 7 ns/100 m 31.25 62.5 100 8.0 9.0 11.4 16.5 21.3 59.0 57.0 54.0 50.0 46.0 7.2 44.2 57.0 39.7 54.0 36.7 52.0 8.0 45.8 42.8 55.0 37.8 52.0 34.8 50.0 10.1 42.9 39.9 52.0 33.9 48.0 30.9 46.0 14.4 38.4 35.4 48.0 27.9 40.0 24.9 38.0 18.2 35.3 32.3 44.0 23.8 34.0 20.8 32.0 250 29.5 – 38.5 – 36.5 – 22.1 – 20.1 – 75.0 56.4 51.8 49.0 43.9 35.6 27.8 9.0 * Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms to EN 50288-2-1) Ordering Information Type designation Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number F/UTP 300/24 4P 5e F/UTP 300/24 4P F/UTP 300/24 8P F/UTP 300/24 4P F/UTP 300/24 4P F/UTP 300/24 8P 300 32.2 – 35.0 – 33.0 – 17.0 – 15.0 – 2.8 5e 4 0.47 Yes 82 6.1 40 1000 CCXDEE-C0047-C001-L7 5e (PVC) 4 0.41 No 82 5.8 36 1000 CCXDLE-C0047-C001-L7 5e 5e (PVC) 5e (PVC) 4 8 4 8 0.47 0.94 0.41 0.94 Yes Yes No No 82 164 82 164 6.1 40 6.2x13.5 82 5.8 36 6.2x13.5 79 *X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 305 1000 305 1000 FutureCom F FutureCom 10TEN Propagation velocity FutureCom E (4x2...) over flat side) Min. bending radius during Unbalance to ground dB/BZL = 100 m FutureCom D -20 to +60°C >_ 35 mm (for 2x >40 dB at 1 MHz CCXDEE-C0047-C001-X1* CCXDEE-C0087-C001-L7 CCXDLE-C0047-C001-X1* CCXDLE-C0087-C001-L7 91 FutureCom UD FutureCom UE Unbalance to ground dB/BZL = 100 m 0 to +50°C for one-time bending at 10 MHz Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz damp rooms Min. bending radius <10 m V/m Hardware Dry and Operating temperature 100 V +/– 15% Surface transfer impedance flame retardant Temperature range (in motion) 125 V +/– 20% Impedance Zo at 1 - 100 MHz Halogen-free, Area/range of application >5000 MV x km Impedance Zo at 0.064 MHz Foam-skin Flex Wire Cable Telephone / for Patch Cord ISDN Products Outer jacket 1% Insulation resistance Industrial Cable Largest resistance margin PE foam skin FRNC: Halogen-free Conductor insulation Special Cable PVC: Electrical Characteristics (at 20°C) Further Information Mechanical Characteristics Introduction FutureCom™ D Cat. 5 Cable F/UTP 300/24 FRNC or PVC FutureCom™ D Module Overview Features Fully compatible with all modular LANscape® systems Wide range of installation options Few individual components High-level component density Individual shielding Halogen free Fire class UL 94 V-0 Optimized construction for bandwidths up to 300 MHz 1500 connector cycles possible Proven IDC technology for conductors with AWG 24 to AWG 23 Module reusable several times Individual Components of the S100e Module S100e Basic Module Features Wire management using TIA/EIA 568 A/B coding Shorter assembly times Easy handling Compatible with FutureCom™ F/UTP and SF/UTP cables Wire Management 92 Corning Cable Systems FutureCom™ D S100e and S100eL Modules Introduction Features Easy and quick to install, no special tools required IDC connection (IDC = Insulation Displacement Contacts) High-level component density FutureCom F Universal application in all modular LANscape® and FutureCom™ components Negligible disturbance effect from interference by means FutureCom 10TEN of the individual shielding of the modules Utilization of additional cable strain relief CAXCSN-00000-C001 is possible for increased pulling CAXDSM-00100-C001 Description S100e Module, 1xRJ45, shielded, Cat.5 (2002), for wire diameter AWG 24 to AWG 23 (F/UTP and SF/UTP cables), incl. copper FutureCom D Order Number Unit per Delivery 1/1 FutureCom UD FutureCom UE Ordering Information FutureCom E forces conducting tape for installation in LANscape patch panels, S100e Double Module, 2xRJ45, shielded, Cat.5 (2002), for wire diameter AWG 24 to AWG 23 (F/UTP and SF/UTP cable), 1/1 Flex Wire Cable Telephone / for Patch Cord ISDN Products CAXDSM-00200-C001 Hardware outlets and floor box solutions incl. copper conducting tape for installation in LANscape modular patch panels, outlets and floor box solutions for wire diameter AWG 23 to AWG 22 (PiMF cable), incl. copper conducting tape 1/1 Industrial Cable S100eL Module, 1xRJ45, shielded, Cat.5 (2002), for installation in LANscape Special Cable modular patch panels, outlets and floor box solutions A Class E link can be constructed in conjunction with a S/FTP data cable and the corresponding Further Information CAXGSM-00100-C001 patch cords. Corning Cable Systems 93 FutureCom™ D S100e Outlets and Patch Panel Ordering Information S100e Outlets Order Number Description S100e Outlet, 2xRJ45, Cat. 5/Cat. 5e, shielded, Unit per Delivery inclined, incl. mounting frame with grounding flaps, 50x50 mm central plate with designation window, screw fixings, CAXDSD-S0201-C001 CAXDSD-S0202-C001 S100e Patch Panel Order Number CAXDSV-02400-C001 copper conducting tape (without face plate) white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Description Unit per Delivery S100e Patch Panel 19“, shielded,Cat.5/Cat.5e, including 24 FutureCom 1/1 S100e modules and copper conducting tape, with integrated cable strain relief, 1 U, high-grade steel front panel Patch panel accessories please see page 156. 94 Corning Cable Systems Order Number CAXDSD-S0200-C001 Description S100e Double Module Outlet, 2x RJ45, Cat. 5, inclined, incl. mounting frame with Unit per Delivery 1/1 FutureCom F Ordering Information Introduction FutureCom™ D S100e Double Module Outlet grounding flaps and copper conducting tape FutureCom 10TEN (suitable for Rutenbeck- compatible central plates FutureCom D FutureCom E or face plates) FutureCom UD FutureCom UE Installation Option S100e Double Module Outlet, 2x RJ45, Cat.5, inclined, incl. mounting frame and copper conducting tape. CAXDSD-S0200-C001 For example, mounted with a Busch-Jaeger central plate and Industrial Cable Further Information Special Cable S100e Double Module Outlet with central plate and face plate (Busch-Jaeger) Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware face plate Corning Cable Systems 95 FutureCom™ D S100eL Outlets and Patch Panel Ordering Information S100eL Outlets Order Number Description S100eL Outlet, 2xRJ45, Cat. 5/Cat. 5e, Unit per Delivery inclined, incl. mounting frame with grounding flaps, 50x50 mm central plate with designation window, screw fixings, CAXGSD-S0201-C001 CAXGSD-S0202-C001 S100eL Patch Panel Order Number CAXGSV-02400-C001 copper conducting tape (without face plate) white, RAL 9010 1/1 Description Unit per Delivery pearl white, RAL 1013 S100eL Patch Panel 19“, shielded,Cat.5/Cat.5e, including 24 FutureCom 1/1 1/1 S100eL modules and copper conducting tape, with integrated cable strain relief, 1 U, high-grade steel front panel Patch panel accessories please see page 156. A Class E link can be constructed using S100eL patch panels and outlets, in conjunction with a S/FTP data cable and the corresponding patch cords. 96 Corning Cable Systems FutureCom™ D Installation Options for Outlets Option 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined, Introduction for three LANscape® modules, white, RAL 9010: WAXWSE-S0301-C001 equipped with two S100e modules FutureCom F CAXDSM-00100-C001 with one MT-RJ module adapter frame LAXLSN-00101-C001 ADP-MTRJ-CNKFL-CLS and two blue SF/UTP flex/26 patch cords CCADNF-D2002-A030-C0 Combi-Frame “DELTAprofil” FutureCom D Option 2: Surface mount outlet, inclined, including mounting frame and central plate 50x 50 mm with designation window, screw fixed, white, RAL 9010: FutureCom UD FutureCom UE CAXDSD-S0201-C001 equipped with one red labeling icon WAXWSE-00007-C001 one gray labeling icon WAXWSE-00003-C001 and one red SF/UTP flex/26 patch cord CCADNF-D5002-A020-C0 combined with surface mount housing Hardware WAXWSE-00001-C003 and one “DELTAfläche” face plate WAXWSE-00001-C002 Flex Wire Cable Telephone / for Patch Cord ISDN Products Double Surface Mount Outlet FutureCom E FutureCom 10TEN with one MT-RJ adapter for multimode connector Option 3: 3-Port frame set for the assembly of three LAN- scape fiber optic or FutureCom copper modules, inclined, including mounting frame and one triple housing with designation window and dust protection flaps and 80x80 mm face plate, white, RAL 9010: Industrial Cable WAXWSE-V0301-C001 equipped with two gray labeling icons WAXWSE-00003-C001 one yellow labeling icon two S100e Modules CAXDSM-00100-C001 and two gray SF/UTP flex/26 patch cords Frame-Set for Three Modules, inclined Corning Cable Systems 97 Further Information Special Cable WAXWSE-00005-C001 FutureCom™ D Cat. 5 Patch Cords RJ45 to RJ45 Description FutureCom D patch cords consist of Cat. 5 flex cable with shielded RJ45 connectors at both ends. The flex cables have four pairs and fully braided copper wire shielding. The patch cords are tested according to IEC 60332-1, Category B. They are available in various lengths and colors. Features SF/UTP flex cable, specified up to 300 MHz Application-neutral due to using all four pairs Minimum surface transfer impedance (<10 mV/m at 10 MHz) Outstanding transmission characteristics according to Channel D (2002) Cat. 5 / 5e Ordering Information CCAD 1 F -D 2 1 Select jacket material. 2 Select color G = FRNC N = PVC 1 2 3 4 5 6 98 = = = = = = gray blue yellow green red black 002 - A 3 3 - C0 Select length. 005 010 015 020 030 040 050 060 075 080 100 150 = = = = = = = = = = = = 0.5 meters 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters Corning Cable Systems FutureCom™ D Plug and Play™ Solutions Introduction Application The S100e Solution Packages are pre-terminated cable sections with S100e modules at both ends. They are gener- ally offered with FutureCom™ F/UTP 300/24 cables. Both FutureCom F modules are equipped with additional cable strain relief to allow higher pulling force during installation (the pulling force is restricted by the cable). They enable Plug and Play™ FutureCom 10TEN installation and therefore significantly reduce installation time. 100% factory testing reduces failures during installa- CCADEE-B2044-A250-C0 CCADEE-B2044-A300-C0 CCADEE-B2044-A350-C0 CCADEE-B2044-A400-C0 CCADEE-B2044-A450-C0 CCADEE-B2044-A500-C0 CCADEE-B2044-A550-C0 CCADEE-B2044-A600-C0 CCADEE-B2044-A650-C0 CCADEE-B2044-A700-C0 CCADEE-B2044-A750-C0 CCADEE-B2044-A800-C0 CCADEE-B2044-A850-C0 CCADEE-B2044-A900-C0 and additional cable strain relief S100e Solution Package F/UTP 300/24 - 10 10 m S100e Solution Package F/UTP 300/24 - 15 15 m S100e Solution Package F/UTP 300/24 - 30 30 m S100e Solution Package F/UTP 300/24 - 20 S100 Solution Package F/UTP 300/24 - 25 e S100e Solution Package F/UTP 300/24 - 35 S100e Solution Package F/UTP 300/24 - 40 S100e Solution Package F/UTP 300/24 - 45 S100 Solution Package F/UTP 300/24 - 50 e 20 m 25 m 35 m 40 m 45 m 50 m S100e Solution Package F/UTP 300/24 - 55 55 m S100 Solution Package F/UTP 300/24 - 70 70 m S100 Solution Package F/UTP 300/24 - 85 85 m S100e Solution Package F/UTP 300/24 - 60 S100e Solution Package F/UTP 300/24 - 65 e S100e Solution Package F/UTP 300/24 - 75 S100e Solution Package F/UTP 300/24 - 80 e S100e Solution Package F/UTP 300/24 - 90 60 m 65 m 75 m 80 m 90 m Hardware CCADEE-B2044-A200-C0 with two S100e modules Flex Wire Cable Telephone / for Patch Cord ISDN Products CCADEE-B2044-A150-C0 data cable, 4 pairs, FRNC jacket pre-terminated Length Industrial Cable CCADEE-B2044-A100-C0 Description S100e Solution Package with F/UTP 300/24 Further Information Order Number Special Cable Ordering Information FutureCom UD FutureCom UE FutureCom D FutureCom E tion. Corning Cable Systems 99 100 Corning Cable Systems 6.3. Cable 6.3.1. Cat. 6 U/UTP 250/23 Cable – FRNC or PVC 106 6.4.1. U250 Module Overview 108 6.4. Connecting Hardware 6.4.2. Keystone Module 109 6.4.3. U250fx Module 110 6.5. Hardware 6.5.1. U250 Outlets and Patch Panel 111 6.6. Patch Cords 112 6.7. Plug & Play™ 113 114 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware 6.7. Test Cable FutureCom F 105 FutureCom 10TEN 6.2. Certificate FutureCom E 102 FutureCom D 6.1. System Descriptions & Data FutureCom UD FutureCom UE FutureCom UE Further Information 6 Introduction Table of contents Corning Cable Systems 101 FutureCom™ UE System FutureCom UE is a system solution developed by Corning for unshielded balanced cabling installations. It meets all require- ments of the standards ISO/IEC 11801 (2002), EN 50173-1 (2003) for Class D and E links and for Category 5 and 6 components. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 U250 outlet, 2xRJ45, Cat.6, inclined, CAXVSD-S0201-C001 U/UTP UEflex/Cat.6, blue, 2xRJ45 connectors, 4 pairs, CCAVGB-D2002-A020-C0 FutureCom U/UTP250/23 Cable CCXVDE-B0042-C001-X1 19“ Patch Panel, for up to 24 LANscape® modules with integrated cable strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001 U250 module, 1xRJ45, unshielded, Cat. 6 CAXVSM-00100-C001 Class E channel performance is achieved using high quality Category 6 connecting hardware, Category 6 cables and the corresponding patch cords. On the basis of configuration with RJ45 connectors and RJ45 modules, the cabling is application neutral and hence universally usable. 102 A FutureCom UE cabling system built in compliance with the standards is therefore highly suitable for all known, standardized voice and data transmission methods. This applies for example to analog voice transmission, ISDN, Token Ring, Ethernet (10Base-T), Fast Ethernet (100Base-TX) and Gi- gabit Ethernet (1000Base-T). The performance of the FutureCom UE cabling system has been certified by an independent test body (see certificate). Corning Cable Systems ACR in dB (typ. FutureCom UE values) Min. ELFEXT in dB * ELFEXT in dB (typ. FutureCom UE values) Min. return loss in dB * Return loss in dB (typ. FutureCom UE values) * According to ISO/IEC 11801 (2002). 8.3 15.2 19.6 25.2 4.0 6.6 9.3 78.0 62.0 57.0 65.0 61.0 76.2 63.3 73.0 19.0 21.0 5.8 56.6 50.0 56.2 43.3 53.0 19.0 21.0 51.6 42.3 48.7 37.2 47.0 17.5 20.0 16.9 43.4 48.0 26.5 32.8 27.3 37.0 14.0 21.7 39.9 45.0 18.2 25.4 23.3 20.0 33.0 12.0 18.0 200 250 27.6 31.7 36.0 42.0 39.0 37.0 36.7 9.0 16.8 19.4 29.0 10.1 17.0 28.6 32.2 34.8 33.1 3.0 -2.8 10.4 4.8 17.3 15.3 27.0 25.0 9.0 8.0 16.0 15.0 The stated system data apply only when original FutureCom UE products are used. Derived values such as PSACR, PSNEXT, PSELFEXT meet the specified standard values but are omitted for clarity of presentation. Attenuation and Near-end Crosstalk (NEXT) NEXT in dB (typ. FutureCom UE values) min. NEXT in dB According to standard max. Attenuation in dB According to standard Attenuation in dB (typ. FutureCom UE values) Further Information Special Cable Industrial Cable in MHz MHz Frequency in Frequency FutureCom F Min. ACR in dB * 155.5 FutureCom 10TEN NEXT in dB (typ. FutureCom UE values) 100 FutureCom E Min. NEXT in dB * 62.5 FutureCom D 1.8 20 FutureCom UD FutureCom UE Attenuation in dB (typ. FutureCom™ UE values) Max. attenuation in dB * 10 Hardware 1 Flex Wire Cable Telephone / for Patch Cord ISDN Products Frequency in MHz Introduction FutureCom™ UE System Data for Channel Class E (2002) Corning Cable Systems 103 FutureCom™ UE System Data for Channel Class E (2002) Far-end Crosstalk (ELFEXT) ELFEXT in dB (typ. FutureCom™ UE values) Min. ELFEXT in dB According to standard Frequency in MHz Return loss Return loss in dB (typ. FutureCom UE values) min. Return loss in dB According to standard Frequency in MHz Test Setup FutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3m U250 Outlet, 2xRJ45 90 m FutureCom U/UTP250/23 U250 Patch Panel 19“ FutureCom UE patch cord UEflex/Cat.6, 2 x RJ45, 3m 104 Nominal intrinsic impedance 100 V Max. DC loop resistance (according to standard) 40 V DC loop resistance (typ. FutureCom UE values) Corning Cable Systems 18 V Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ UE Certificate Corning Cable Systems 105 FutureCom™ UE Cat. 6 Cables U/UTP 250/23 FRNC or PVC Jacket FRNC or PVC Central cross member Twisted pair Copper conductor AWG 23 Foam skin PE insulation Application The FutureCom™ U/UTP 250/23 cable is designed for appli- cations up to 250 MHz and provides transmission performance exceeding Category 6 specifications. FutureCom cables are low skew products, i.e. the skew between the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. Additional features are the slim design and low weight of the cables. Features U/UTP 250/23 cable, specified up to 250 MHz Excellent electrical characteristics Mechanical Characteristics Outer jacket FRNC Version: PVC Version: Area/range of application Temperature range (installation) Operating temperature Min. bending radius for one time bending Min. bending radius during installation Copper conductor 106 Central cross member reduces risk of crushing or kinking Zero halogen, flame retardant PVC, flame retardant Dry and damp rooms 0 to +50°C -20 to +60°C 26 mm 52 mm Central cross member can be cut off easily for installation of connecting hardware Low skew between the pairs Low weight Flame retardant to IEC 60332-1, Category B Special Features of FRNC Version Zero halogen version (ZH) Non corrosive to IEC 60754-2 (NC) Low smoke to IEC 61034 (LS) AWG 23 Corning Cable Systems FutureCom™ UE Cat. 6 Cables U/UTP 250/23 FRNC or PVC Introduction Electrical Characteristics (at 20°C) 56 nF/km 70 V/ km 100 V +/ – 15 % 0.68 x c FutureCom 10TEN 5.36 ns/m FutureCom E 30 ns/100 m Electrical Characteristics (at 20°C) Frequency in MHz 1 10 16 20 31.25 62.5 100 250 66.0 59.3 56.2 54.8 51.9 47.4 44.3 38.3 Attenuation in dB/100m * 2.1 Typical values in dB at 100m 74.3 Typical values dB/100m 2.0 Next in dB at 100 m * PSNEXT in dB at 100 m * 64.0 Typical values in dB at 100m 72.3 ELFEXT in dB at 100 m * 66.0 Typical values in dB at 100m 75.3 PSELFEXT in dB at 100 m * 64.0 Typical values in dB at 100m 72.3 ACR in dB 72.3 6.0 6.0 59.3 57.3 57.3 50.0 55.3 47.0 52.3 53.3 7.6 8.5 7.6 8.5 56.3 54.8 54.2 52.8 54.3 52.8 45.9 44.0 51.2 49.3 43.0 41.0 48.2 46.3 48.7 46.3 * Standard: Requirements on 100 m installed Category 6 cable (conforms with EN 50288-6-1) 10.7 10.6 51.9 49.9 49.9 40.1 45.4 37.1 42.4 41.2 15.5 15.3 47.4 45.4 45.4 34.1 39.4 31.1 36.4 32.1 19.9 19.6 44.3 42.3 42.3 30.0 35.3 27.0 32.3 24.7 33.0 32.3 38.3 36.3 36.3 22.0 27.3 19.0 24.3 6.0 Flex Wire Cable Telephone / for Patch Cord ISDN Products Delay skew Ordering Information Type designation Category U/UTP 250/23 4P 6 U/UTP 250/23 4P U/UTP 250/23 4P U/UTP 250/23 4P 6 6 6 Max. Outer [ Weight Length No. of Fire Load Halogen- Tensile (kg/km) (m) Order Number Pairs (MJ/m) free Strength(N) (mm) 4 0.56 Yes 100 6.0 42 305 CCXVDE-B0042-C001-X1 4 0.52 No 100 5.8 39 1000 CCXVKE-B0042-C002-L7 4 4 0.56 0.52 Yes No 100 100 6.0 5.8 42 39 305 CCXVDE-B0042-C001-L7 CCXVKE-B0042-C002-X1* Further Information *X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels. 1000 FutureCom D at >10 MHz (NVP x C) Propagation delay >_ 10 MHz FutureCom UD FutureCom UE Propagation velocity FutureCom F 45 dB Coupling attenuation at 30 MHz Hardware Characteristic impedance Industrial Cable DC resistance Special Cable Mutual Capacity Corning Cable Systems 107 FutureCom™ UE Module Overview Features Paired installation (no untwisting of pairs required) Significantly faster installation times Easy handling Compatible with all FutureCom™ UE cables Fully compatible with all modular LANscape® outlets, patch panels and floor box solutions Wide range of installation options Few individual parts High level component density Halogen-free Fire class UL94V-0 Optimized design with circuit board for bandwidths of more than 300 MHz Individual Components of the U250 Module 1500 mating cycles possible Proven IDC termination for wires with AWG 24 to AWG 22 Module re-usable up to several times Disassembled U250 Basic Module Features Wire management using TIA/EIA 568 A/B coding Installation in pairs (no untwisting of the pairs is necessary) Rapid assembly times Easy handling Compatible with FutureCom™ Cat. 6 U/UTP cables Wire Management 108 Corning Cable Systems FutureCom™ UE U250 Modules Introduction Features Easy and quick to install, no special tools required IDC connection (IDC = Insulation Displacement Contacts) High-level component density FutureCom F Universal usage in all modular LANscape® and FutureCom™ components FutureCom 10TEN Category 6 (2002), de-embedded CAXVSM-00100-C001 Description U250 Module, 1xRJ45, unshielded, Cat. 6, for installation in LANscape modular patch panels, Unit per Delivery FutureCom E Order Number 1/1 FutureCom D Ordering Information U250 Keystone Module, 1 x RJ45, unshielded, Cat. 6. for installation Hardware Unit per Delivery 1/1 in patch panels, outlets and floor box solutions Industrial Cable with keystone design Special Cable CAXKSM-00100-C001 Description Further Information Order Number Flex Wire Cable Telephone / for Patch Cord ISDN Products U250 Keystone Module FutureCom UD FutureCom UE outlets and floor box solutions Corning Cable Systems 109 FutureCom™ UE U250fx Module Application U250fx Modules are used for the assembly of consolidation point cables with flexible wires Features Fully compatible with all modular LANscape® connecting hardware Wide range of installation options Minimal number of parts Proven IDC technology for AWG 24 and AWG 26 stranded wires Individual Parts of the U250fx Module Module reusable several times 1500 mating cycles possible Wire management with A/B printing (according to TIA/EIA 568) Paired installation (no untwisting of pairs required) Easy handling Category 6, de-embedded Requirements for Consolidation Point Cables Additional cable strain relief is neccessary for assembling the flex wire modules Assembled U250fx Module (with additional cable strain relief) CCS patch cords with RJ45 connectors are wired according to TIA/EIA 568 B; when using other single-ended preterminated connecting cables, they should be wired according to the RJ45 connector scheme Installed solid wire cables should have a lower attenuation specification than the flexible cable Ordering Information Order Number CAXVSM-00100-C003 Description U250fx Module, 1xRJ45, unshielded, Cat.6 especially designed for consolidation point cables with AWG 24/26 stranded wires, incl. additional cable strain relief for mounting in LANscape hardware 110 Corning Cable Systems Units per Delivery 1/1 FutureCom™ UE U250 Outlets and Patch Panel Order Number Description U250 Outlet, 2xRJ45, unshielded, Cat. 6, inclined, Unit per Delivery FutureCom F U250 Outlets Introduction Ordering Information FutureCom 10TEN incl. mounting frame with grounding flaps, central plate 50x50 mm U250 Patch Panel Order Number CAXVSV-02400-C001 white, RAL 9010 1/1 Description Unit per Delivery U250 Patch Panel 19“, unshielded, Cat. 6, incl. 24 FutureCom U250 1/1 FutureCom D pearl white, RAL 1013 FutureCom UD FutureCom UE CAXVSD-S0202-C001 (without face plate) 1/1 Hardware CAXVSD-S0201-C001 screw-fixed, FutureCom E with designation window, modules, Flex Wire Cable Telephone / for Patch Cord ISDN Products with integrated cable strain relief, 1 U, high-grade steel front panel Further Information Special Cable Industrial Cable Patch panel accessories please see page 156. Corning Cable Systems 111 FutureCom™ UE Cat. 6 Patch Cords RJ45 to RJ45 Description FutureCom UE patch cords consist of Category 6 flexible cable, with unshielded RJ45 connectors at both ends. The zero-halogen patch cords (LSZH) are non-corrosive (according to IEC 60754-2), low smoke (according to IEC 61034) and flame retardant (according to IEC 60332-1, Category B). They are available in different lengths and colors. Features U/UTP flex cable, specified up to 250 MHz Application-neutral due to using all four pairs Outstanding transmission characteristics according to Channel E (2002) Cat. 6 Ordering Information CCAVGB - D 1 Select color. 2 Select length. 1 002 - A 2 - C0 1 = gray 2 = blue 4 = green 010 020 030 050 060 100 112 = = = = = = 1 meter 2 meters 3 meters 5 meters 6 meters 10 meters Corning Cable Systems FutureCom™ UE Plug & Play™ Solutions Introduction Application The U250 Solution Packages are pre-terminated cables with U250 modules at both ends. They are generally offered with FutureCom F FutureCom™ U/UTP 250/23 cables. Both modules are equipped with additional cable strain relief, to allow higher pulling force during insertion (the pulling force is restricted FutureCom 10TEN by the cable only). They enable Plug and Play™ installation CCAVDE-C1056-A250-C0 CCAVDE-C1056-A300-C0 CCAVDE-C1056-A350-C0 CCAVDE-C1056-A400-C0 CCAVDE-C1056-A450-C0 CCAVDE-C1056-A500-C0 CCAVDE-C1056-A550-C0 CCAVDE-C1056-A600-C0 CCAVDE-C1056-A650-C0 CCAVDE-C1056-A700-C0 CCAVDE-C1056-A750-C0 CCAVDE-C1056-A800-C0 CCAVDE-C1056-A850-C0 CCAVDE-C1056-A900-C0 U250 Solution Package U/UTP 250/23 - 10 10 m U250 Solution Package U/UTP 250/23 - 15 15 m U250 Solution Package U/UTP 250/23 - 30 30 m U250 Solution Package U/UTP 250/23 - 20 U250 Solution Package U/UTP 250/23 - 25 U250 Solution Package U/UTP 250/23 - 35 U250 Solution Package U/UTP 250/23 - 40 U250 Solution Package U/UTP 250/23 - 45 U250 Solution Package U/UTP 250/23 - 50 U250 Solution Package U/UTP 250/23 - 55 U250 Solution Package U/UTP 250/23 - 60 U250 Solution Package U/UTP 250/23 - 65 U250 Solution Package U/UTP 250/23 - 70 U250 Solution Package U/UTP 250/23 - 75 U250 Solution Package U/UTP 250/23 - 80 U250 Solution Package U/UTP 250/23 - 85 U250 Solution Package U/UTP 250/23 - 90 20 m 25 m 35 m 40 m 45 m 50 m 55 m 60 m 65 m 70 m 75 m 80 m 85 m 90 m Hardware CCAVDE-C1056-A200-C0 with 2 U250 modules and additional cable strain relief Flex Wire Cable Telephone / for Patch Cord ISDN Products CCAVDE-C1056-A150-C0 4 pairs, FRNC jacket pre-terminated Length Industrial Cable CCAVDE-C1056-A100-C0 Description Solution Package, U/UTP 250/23 cable, Further Information Order Number Special Cable Ordering Information FutureCom UD FutureCom UE FutureCom D FutureCom E and therefore significantly reduce installation time. Corning Cable Systems 113 FutureCom™ UE Universal Test Cord for Channel Testing Application This universal channel test cord is suitable for acceptance tests of unshielded FutureCom™ UE systems in conjunction with the universal test adapters from Fluke or other manufacurers. One pair of these test cords is required for acceptance tests. Ordering Information Order Number CCAVFG-D10M0-A030-C0 Description Universal test cord for the acceptance tests of the FutureCom UE System in conjuntion with the universal test adapters from Fluke, or other test device manufactures, gray, 2xRJ45 connectors, 4 pairs, 3 m 114 Corning Cable Systems Units per Delivery 1/1 7.3. Cable 7.3.1. U/UTP 100/24 Cable FRNC or PVC 120 7.4.1. U100e Module Overview 122 7.4. Connecting Hardware 7.4.2. U100e Module 123 7.5. Hardware 7.5.1. U100e Outlets and Patch Panel 124 125 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware 7.6. Patch Cords FutureCom F 119 FutureCom 10TEN 7.2. Certificates FutureCom E 116 FutureCom D 7.1. System Description & Data FutureCom UD FutureCom UE FutureCom UD Further Information 7 Introduction Table of contents Corning Cable Systems 115 FutureCom™ UD System FutureCom UD (2002) is Corning’s Class D solution for unshielded balanced cabling. It meets all requirements of the standard ISO/IEC 11801 (2002) and EN 50173-1 (2003) for Class D links and Category 5 components. In addition, the FutureCom UD also satisfies Category 5e according to TIA/EIA 566-A-5. Face Plate “DELTAfläche”, 75x75 mm WAXWSE-00001-C002 U100e outlet, 2xRJ45, Cat.5, inclined, CAXUSD-S0201-C001 U/UTP flex/26, gray, 2xRJ45 connectors, 4 pairs, for 10/100/1000 Base-T CCAUGE-D1002-A030-C0 FutureCom U/UTP100/24 Cable CCXUEE-A0047-C001-L7 19“ Patch Panel, for up to 24 LANscape® modules with integrated strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001 U100e module, 1xRJ45, unschielded, Cat. 5 CAXUSM-00100-C001 Class D (2002) channel performance is achieved through the use of high quality Category 5 connecting hardware, cables and patch cords. On the basis of configuration with RJ45 connectors and the RJ45 module, the cabling is application neutral and hence universally usable. 116 A FutureCom UD cabling system built in compliance with the standards is suitable for standardized voice and data transmission methods. This applies for example to analog voice transmission, ISDN, Token Ring, Ethernet (10-Base-T), Fast Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T). The performance of the FutureCom UD cabling system has been certified by an independent test body (see certificate). Corning Cable Systems Min. ACR in dB * ACR in dB (typ. FutureCom UD values) Min. ELFEXT in dB * ELFEXT in dB (typ. FutureCom UD values) Min. return loss in dB * Return loss in dB (typ. FutureCom UD values) * According to ISO/IEC 11801 (2002). 57.8 62.6 57.0 67.0 17.0 19.0 62.5 6.3 8.0 9.4 11.5 16.0 4.5 7.0 55.0 51.0 50.6 46.1 51.1 45.0 57.0 17.0 21.0 44.0 37.0 44.7 37.0 49.0 17.0 22.0 9.2 40.6 46.5 31.4 38.5 32.9 45.0 17.0 22.0 10.3 39.0 45.0 28.7 35.6 31.0 43.0 17.0 22.0 12.8 35.7 40.0 22.9 30.5 27.0 39.0 15.1 20.1 100 18.5 24.0 35.5 32.0 21.9 30.6 27.1 12.1 3.1 19.5 10.1 21.1 17.0 33.0 29.0 12.1 10.1 17.0 15.0 The stated system data apply only when original FutureCom UD products are used. Derived values such as PSACR, PSNEXT, PSELFEXT meet the specified standard values but are omitted for clarity of presentation. Attenuation and near-end crosstalk (NEXT) NEXT in dB (typ. FutureCom UD values) min. NEXT in dB According to standard max. Attenuation in dB According to standard Attenuation in dB (typ. FutureCom UD values) Further Information Special Cable Industrial Cable in MHz MHz Frequency in Frequency in MHz Frequency FutureCom F 65.0 60.3 31.25 FutureCom 10TEN NEXT in dB (typ. FutureCom UD values) Min. NEXT in dB * 20 FutureCom E 3.9 4 Attenuation in dB (typ. FutureCom™ UD values) 16 FutureCom D 2.4 Max. attenuation in dB * 10 FutureCom UD FutureCom UE 4 Hardware 1 Flex Wire Cable Telephone / for Patch Cord ISDN Products Frequency in MHz Introduction FutureCom™ UD System Data for Channel Class D (2002) Corning Cable Systems 117 FutureCom™ UD System Data Equal level far-end crosstalk (ELFEXT) ELFEXT in dB typ. FutureCom™ UD values) Min. ELFEXT in dB According to standard Frequency in MHz Return loss in dB Return loss in dB (typ. FutureCom UD values) min. Return loss in dB According to standard Frequency in MHz Test Setup FutureCom UD Patch Cord U/UTP flex/26, 2m U100e FutureCom Modules, 2 x RJ45 90 m FutureCom U/UTP100/24 U100e Patch Panel 19“ FutureCom UD Patch Cord U/UTP flex/26, 2m 118 Nominal impedance Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom UD values) Corning Cable Systems 100 V 40 V 18 V Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction FutureCom™ UD Certificates for Channel Class D (2002) Corning Cable Systems 119 FutureCom™ UD Cat. 5e Cables U/UTP 100/24 FRNC or PVC Jacket FRNC or PVC Twisted pair Copper conductor AWG 24 Foam skin PE insulation Application The FutureCom™ U/UTP 100/24 cable is designed for appli- cations up to 100 MHz and provides transmission performance exceeding Category 5 and 5e specifications. FutureCom cables are low skew products, i.e. the skew be- tween the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. Additional features are the slim design and low weight of the cables. Features U/UTP 100/24 cable, specified up to 100 MHz Mechanical Characteristics Conductor insulation Outer jacket Core and pairs are unshielded Excellent electrical values Slim design PVC: Flame retardant Color Coding Dry and Pair 2 FRNC: FRNC: Operating temperature Zero Halogen foam-skin material Zero Halogen flame retardant damp rooms 0 to +50°C -20 to +60°C Min. bending radius >_ 25 mm (for 2x installation (4x2...) over flat side) Min. bending radius during 120 IEC 60332-3, Category C PE foam-skin material Temperature range (installation) Copper conductor Halogen-free (LSZH) jacket, flame retardant to PVC: Area/range of application for one-time bending Low weight PVC jacket, flame retardant to IEC 60332-1, Category B Pair 1 Pair 3 Pair 4 (4x2...) over flat side) >_ 40 mm (for 2x AWG 24 Corning Cable Systems white with blue rings/blue white with orange rings/orange white with green rings/green white with brown rings/brown FutureCom™ UD Cat. 5e Cables U/UTP 100/24 FRNC or PVC Max. resistance unbalance 3% Impedance Zo at 1 – 100 MHz 100 V +/– 15% Introduction Electrical Characteristics (at 20°C) >5000 V x km Return loss: 4 – 10 MHz >_ 20 + 5 log (f) Longitudinal conversion loss dB/ref. > 43 dB at 64 kHz FutureCom 10TEN FutureCom E 45 pF/m 0.74 x c at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 4.5ns/m Electrical Characteristics (at 20°C) Frequency in MHz 1 10 16 20 65.3 50.3 47.3 45.8 Attenuation in dB/100m * 2.1 Typical values in dB at 100m 77,4 Typical values dB/100m 1.9 NEXT in dB at 100 m * PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 74.0 ELFEXT in dB at 100 m * 63.8 Typical values in dB at 100m 68.0 PSELFEXT in dB at 100 m * 60.8 Typical values in dB at 100m 66.0 ACR in dB 74.1 6.3 5.9 65.5 47.3 60.0 43.8 49.0 40.8 47.0 56.1 8.0 7.4 62.2 44.2 56.0 39.7 45.0 36.7 43.0 50.6 62.5 42.9 38.4 11.4 59.7 57.7 8.4 42.8 54.0 37.8 42.0 34.8 40.0 47.6 * Standard: Requirements on 100 m installed Category 5e cable (conforms with EN 50288-3-1) Ordering Information 31.25 9.0 10.5 39.9 51.0 33.9 40.0 30.9 38.0 42.5 21.3 49.6 46.6 15.1 35.4 47.0 27.9 33.0 24.9 31.0 33.9 Type designation Max. Outer [ Weight Length Fire Load Halogen Tensile (kg/km) (m) Order Number Strength(N) (mm) (MJ/m) Free U/UTP 100/24 8P 5e 1.22 U/UTP 100/24 4P U/UTP 100/24 4P U/UTP 100/24 8P 5e 4 5e 4 5e 5e 8 4 8 100 16.5 No. of Category Pairs U/UTP 100/24 4P FutureCom D 7 ns/100 m Delay skew 19.3 35.3 32.3 44.0 23.8 28.0 20.8 26.0 26.7 0.59 Yes 82 6.2 44 1000 CCXUEE-A0047-C001-L7 0.32 No 82 5.0 28 1000 CCXULE-A0047-C004-L7 0.32 0.76 Yes No No 164 82 164 6.0x13.0 88 5.0 28 5.0x12.0 56 *X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels. Corning Cable Systems 1000 305 1000 CCXUEE-A0087-C001-L7 CCXULE-A0047-C004-X1* CCXULE-A0087-C004-L7 121 FutureCom UD FutureCom UE Propagation velocity Hardware Mutual capacity >_ 25 dB - 7 log (f/20) Flex Wire Cable Telephone / for Patch Cord ISDN Products length = 1000m >_ 25 dB Industrial Cable Return loss: > 20 MHz Special Cable Return loss: 10 – 20 MHz FutureCom F 125 V +/– 20% Impedance Zo at 0.064 MHz Further Information Insulation resistance FutureCom™ UD Module Overview Features Fully compatible with all modular LANscape® and FutureCom™ systems Wide range of installation options Few individual parts High level component density Optimized design for bandwidths of up to 100 MHz 1500 mating cycles possible Proven IDC termination for wires with AWG 24 to AWG 23 Module re-usable several times Halogen-free Individual Parts of the U100e Module Fire class UL 94V-0 U100e Basic Module Features Wire management using TIA/EIA 568 A/B coding Shorter installation times Easy handling Compatible with FutureCom U/UTP Cat. 5 cables Wire Management 122 Corning Cable Systems FutureCom™ UD U100e Module Introduction Features Easy and quick to install, no special tools required IDC connection (IDC = Insulation Displacement Contact) High level component density U100e module, 1xRJ45, unshielded, Cat. 5 (2002) for installation in modular LANscape patch panels, FutureCom 10TEN Units per Delivery 1/1 Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D outlets and floor box solutions Special Cable CAXUSM-00100-C001 Description Further Information Order Number FutureCom E Ordering Information FutureCom F Universally usable in all modular LANscape® components Corning Cable Systems 123 FutureCom™ UD U100e Outlets and Patch Panel Ordering Information U100e Outlets Order Number Description U100e Outlet, 2xRJ45, Cat. 5/Cat. 5e, Unit per Delivery unshielded, inclined, incl. mounting frame with grounding flaps, 50x50 mm central plate with designation CAXUSD-S0201-C001 CAXUSD-S0202-C001 U100e Patch Panel Order Number CAXUSV-02400-C001 window, screw fixings, (without face plate) white, RAL 9010 1/1 Description Unit per Delivery pearl white, RAL 1013 U100e Patch Panel 19“, unshielded, Cat. 5/Cat. 5e, including 24 FutureCom 1/1 1/1 U100e modules, with integrated cable strain relief, 1 U, high-grade steel front panel Patch panel accessories please see page 156. 124 Corning Cable Systems FutureCom™ UD Cat. 5 Patch Cords RJ45 to RJ45 Introduction Description FutureCom UD system patch cords consist of Category 5 flexible cables and are terminated with unshielded RJ45 connectors at both ends. The patch cords are flame FutureCom F retardant according to IEC 60332-1, Category B. They are available in various lengths and colors. FutureCom 10TEN Features U/UTP flex cable, specified up to 100 MHz FutureCom E Application-neutral due to using all four pairs Outstanding transmission characteristics according to Channel D (2002) CCAU 1 E-D 1 Select cable type. 2 Select color. 3 Select length. 2 002 - A 3 FutureCom UD FutureCom UE Ordering Information FutureCom D Category 5 (2002) or 5e according to TIA/EIA - C0 = = = = = = = Flex Wire Cable Telephone / for Patch Cord ISDN Products Industrial Cable 005 010 020 030 040 050 060 gray blue yellow green red black 0.5 meters 1 meter 2 meters 3 meters 4 meters 5 meters 6 meters Special Cable = = = = = = Further Information 1 2 3 4 5 6 Hardware G = FRNC N = PVC Corning Cable Systems 125 126 Corning Cable Systems 8.1.2. Metal Outlets 138 8.2. Accessories for Floor Box Solutions 144 8.4. Consolidation Point Housing 157 8.3. Patch Panel and Patch Panel Accessories 152 8.5. Tools and Accessories 158 162 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE 8.6. 1000 RT FutureCom F 128 FutureCom 10TEN 8.1.1. Standard Outlets FutureCom E 8.1. Outlets and Outlet Accessories FutureCom D Hardware Further Information 8 Introduction Table of contents Corning Cable Systems 127 Outlets and Outlet Accessories Application The LANscape® System offers outlet solutions for all instal- lation options and mounting methods. There are various styles available for surface, flush or raceway mounting. Using various frame sets from the LANscape system, outlet configurations with 1 to 6 ports can be individually com- bined. The frame sets with a central plate size of 50 x 50 mm can be combined with our “DELTAprofil” and “DELTAfläche” face plates, as well as those of other manufacturers. Ordering Information Order Number WAXWSM-00101-C001 WAXWSM-00108-C001 Description Blank Cover, 1 position for installation in modular LANscape patch panels, outlets and floor box solutions white, RAL 9010 black, RAL 9005 Frame Sets for the Individual Configuration of Outlets Order Number Description Frame Set, straight, for 2 FutureCom™ modules, Units per Delivery 6/1 6/1 Units per Delivery including mounting frame WAXWSE-G0201-C001 WAXWSE-G0202-C001 128 and 50x50 mm central plate with designation window, screw fixing white, RAL 9010 pearl white, RAL 1013 Corning Cable Systems 1/1 1/1 Outlets and Outlet Accessories Order Number Description Frame Set, inclined, with grounding flap, for 2 LANscape® modules, Units per Delivery FutureCom F Frame Sets for the Individual Configuration of Outlets Introduction Ordering Information WAXWSE-S0202-C001 window, screw fixing white, RAL 9010 pearl white, RAL 1013 1/1 1/1 FutureCom E WAXWSE-S0201-C001 50x50 mm central plate with designation FutureCom 10TEN including mounting frame and FutureCom D Design Line - Special Color Options Frame Set, inclined, with grounding flap, for 2 LANscape® modules, WAXWSE-S0203-C001 50x50 mm central plate with designation window, screw fixing gray, RAL 7035 FutureCom UD FutureCom UE including mounting frame and 1/1 Frame Set, inclined, with grounding Hardware flap, for 2 LANscape® modules, WAXWSE-S0208-C001 50x50 mm central plate with designation window, screw fixing black, RAL 9005 Flex Wire Cable Telephone / for Patch Cord ISDN Products including mounting frame and 1/1 Projecting Frame Set for the Individual Configuration of Outlets Description Frame Set, inclined, projecting, for 2 LANscape modules, Units per Delivery Industrial Cable Order Number Special Cable including mounting frame and WAXWSE-V0201-C001 WAXWSE-V0202-C001 with designation window and dust protection flaps white, RAL 9010 pearl white, RAL 1013 Further Information 50x50 mm central plate 1/1 1/1 Corning Cable Systems 129 Outlets and Outlet Accessories Ordering Information Frame Set, inclined, projecting, 3- or 6-Port Outlet Order Number Description Frame Set, inclined, projecting, for 3 LANscape® modules, Units per Delivery including mounting frame and triple housing with designation window, WAXWSE-V0301-C001 WAXWSE-V0302-C001 dust protection flaps and face plate 80x80 mm white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Frame Set, inclined, projecting, for 6 LANscape modules, including mounting frame and two triple housings with designation window, WAXWSE-V0601-C001 WAXWSE-V0602-C001 dust protection flaps and face plate 151x80 mm white, RAL 9010 1/1 pearl white, RAL 1013 1/1 Installation Option: 6-Port Frame Set for the mounting of 6 LANscape modules, inclined, including mounting frame and two triple housings with designation window and dust protection flaps and face plate 151 x 80 mm, white, RAL 9010; WAXWSE-V0601-C001 equipped with two S250 modules CAXESM-00100-C001 two black labeling icons WAXWSE-00008-C001 four blue labeling icons WAXWSE-00004-C001 and two blue S/FTP/flex patch cables Outlet for 6 modules, Inclined 130 CCAEGB-G2002-A030-C0 Corning Cable Systems Outlets and Outlet Accessories Introduction Labeling Icons and Designation Labels All frame sets with a 50x50 mm central plate as well as the 3- and 6-port frame sets offer the opportunity to code each port with labeling icons. The icons indicate port applications FutureCom F and show a telephone or a computer (LAN operation). They are available in six different colors. Furthermore, these frame sets have a designation window with a clear cover, for WAXWSE-00007-C001 WAXWSE-00008-C001 WAXWSE-00001-C009 Labeling Icon, computer/telephone, yellow, RAL 1021 Labeling Icon, computer/telephone, green, RAL 6029 Labeling Icon, computer/telephone, red, RAL 3000 120/1 120/1 120/1 DIN A4 Title Strip Sheet, 10/1 with 150 designation labels for LANscape® outlets, white, FutureCom E 120/1 Labeling Icon, computer/telephone, black, RAL 9005 FutureCom D blue, RAL 5015 120/1 FutureCom UD FutureCom UE WAXWSE-00006-C001 120/1 gray, RAL 7042 Hardware WAXWSE-00005-C001 Labeling Icon, computer/telephone, Labeling Icon, computer/telephone, e.g. for labeling using a PC-printer Industrial Cable WAXWSE-00004-C001 Units per Delivery Special Cable WAXWSE-00003-C001 Description Further Information Order Number Flex Wire Cable Telephone / for Patch Cord ISDN Products Ordering Information FutureCom 10TEN inserting a designation label. Corning Cable Systems 131 Outlets and Outlet Accessories Ordering Information Face Plates for 50 x 50 mm Central Plates Order Number WAXWSE-00001-C001 WAXWSE-00002-C001 Description “DELTAprofil” Face Plate, 80x80 mm, for LANscape® outlets with 50x 50 mm central plate white, RAL 9010 pearl white, RAL 1013 Units per Delivery 1/1 1/1 “DELTAfläche” Face Plate, 75x75 mm, WAXWSE-00001-C002 WAXWSE-00002-C002 for LANscape outlets with 50x 50 mm central plate white, RAL 9010 pearl white, RAL 1013 Surface Mount Housing for “DELTAfläche” Outlets Order Number WAXWSE-00001-C003 WAXWSE-00002-C003 132 Description “DELTAfläche” Surface Mount Housing, for the individual configuration of LANscape outlets, 75x75 mm white, RAL 9010 pearl white, RAL 1013 Corning Cable Systems 1/1 1/1 Units per Delivery 1/1 1/1 Outlets and Outlet Accessories WAXWSE-S0301-C001 Units per Delivery white, RAL 9010 1/1 “DELTAprofil” Combi-Frame, 80x80 mm, inclined, for 3 LANscape® modules pearl white, RAL 1013 1/1 Installation Options 1/1 1/1 FutureCom UD FutureCom UE pearl white, RAL 1013 Hardware Option 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined , white, RAL 9010; WAXWSE-S0301-C001 equipped with two S250 Modules, CAXESM-00100-C001 and one LC Duplex Module for multimode connectors LAXLSM-00101-C007 Option 2: “DELTAfläche” Combi-Frame, 75x75 mm, Industrial Cable “DELTAprofil”Combi-Frame inclined , white, RAL 9010; WAXWSE-S0301-C002 equipped with two S100e Modules, CAXDSM-00100-C001 and one single MT-RJ Module for single-mode/multimode “DELTAprofil” Combi-Frame connectors LAXLSM-00101-C004 Corning Cable Systems Flex Wire Cable Telephone / for Patch Cord ISDN Products white, RAL 9010 Special Cable WAXWSE-S0302-C002 inclined, for 3 LANscape modules 133 Further Information WAXWSE-S0301-C002 “DELTAfläche” Combi-Frame, 75x75 mm, FutureCom D FutureCom E WAXWSE-S0302-C001 Description FutureCom F Order Number FutureCom 10TEN Combi-Frames Introduction Ordering Information Outlets and Outlet Accessories Brackets for Raceway Mounting The following brackets can be used for the quick and simple installation of outlets and frame sets in raceways. They support the minimum bend radius requirements for copper and fiber optic cables. In order to separate network components from power systems, the brackets are supplied with a removable half-shell partition, which can be optionally inserted. An additional advantage of the half-shell partition is the protection of fiber optic connections against mechanical damage during pulling of new cables. The brackets are suitable for Tehalit and Ackermann raceways with T-groove mounting. Ordering Information Order Number WAXWSE-00001-C010 Description Brackets for Raceway Mounting of outlets and frame sets, T-groove mounting, height 50 mm, with half-shell partition, Units per Delivery 1/1 white, RAL 9010 WAXWSE-00008-C002 Brackets for Raceway Mounting of outlets and frame sets, T-groove mounting, height 55 mm, with half-shell partition, black, RAL 9005 134 Corning Cable Systems 1/1 Description WAXWSE-00001-C008 Surface Mount Housing, 67x110 mm, WAXWSE-V0201-C004 Combi-Frame, 67x110 mm, for combi-frame (67x110 mm), 1/1 for installation of two single LANscape® modules, FutureCom E FutureCom 10TEN white, RAL 9010 Units per Delivery 1/1 FutureCom D Order Number FutureCom F Ordering Information Introduction Outlets and Outlet Accessories inclined, CAXCSE-G0201-C001 Combi-Frame, 45x45 mm, with self-closing shutters for the installation of 2 FutureCom™ FutureCom UD FutureCom UE white, RAL 9010 1/1 Hardware modules, straight, Combi-Frame for VanGeel Columns, 45x45 mm, with self-closing shutters for the installation of 2 FutureCom Units per Delivery 1/1 modules, straight, white, RAL 9010 Special Cable CAXCSE-G0201-C002 Description Further Information Order Number Industrial Cable Combi-Frames for VanGeel Columns Flex Wire Cable Telephone / for Patch Cord ISDN Products white, RAL 9010 Corning Cable Systems 135 Outlets and Outlet Accessories Ordering Information Order Number WAXWSE-00001-C004 Description Surface Mount Housing, 87x87 mm, including two screws for face plate (87x87 mm), Units per Delivery 1/1 white, RAL 9010 WAXWSE-00001-C005 Face plate, 87x87 mm, for one module housing, including two metric screws 1/1 and two whitworth screws, for face plate mounting in installation outlets, white, RAL 9010 WAXWSE-00001-C006 Surface Mount Housing, 87x147 mm, including two screws for face plate (87x147 mm), 1/1 white, RAL 9010 WAXWSE-00001-C007 Face Plate, 87x147 mm, for two module housings, including two metric screws and two whitworth screws, for face plate mounting in installation outlets, white, RAL 9010 136 Corning Cable Systems 1/1 Order Number CAXCSE-V0201-C001 Description Module Housings with self-closing shutters, projecting, inclined, for face plates Units per Delivery 1/1 FutureCom F Ordering Information Introduction Outlets and Outlet Accessories (147x87 mm and 87x87 mm) FutureCom 10TEN for the installation of 2 FutureCom™ Universal Module Housing, projecting, inclined, for face plates (147x87 mm and 1/1 FutureCom D WAXWSE-V0201-C002 FutureCom E modules, white, RAL 9010 87x87 mm) for the installation of 2 FutureCom™ modules, FutureCom UD FutureCom UE central partition provided, white, RAL 9010 Surface Combi-Frame Set, 75x65 mm, with self-closing shutters for the installation of 2 FutureCom modules, 1/1 Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware straight, white, RAL 9010 Further Information CAXCSE-U0201-C001 Corning Cable Systems 137 Metal Outlets for Industrial Applications Application The 2-port LANscape® industrial metal outlets with integrated cable strain relief can be equipped with any LANscape fiber optic or copper modules. The outlet is suitable for harsh environmental conditions and can be mounted on a surface, as well as in different configurations (see page 139) on top hat rails (35 mm DIN rails). Features Integrated cable strain relief for two individual cables (separate assembly possible) Metal construction suitable for harsh environmental conditions in industrial surroundings Conductive housing for shielded FutureCom™ modules Non-detachable designation label Cable entry with brush strip provides dust protection regardless of cable diameter Non-detachable housing fastening screw Horizontal and vertical top hat rail mounting Excess length storage for fiber without exceeding minimum bending radius Retrofitting and re-equipping possible without complete disassembly (2-piece housing) Ordering Information Order Number WAXWSD-V0208-C001 Description 2-Port Metal Outlet for Industrial Applications, 60x65x121 mm (HxWxD), Unit per Delivery 1/1 for the installation of 2 LANscape modules, inclined, projecting, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016 * * Other colors upon request 138 Corning Cable Systems Metal Outlets for Industrial Applications often have different distances between the top hat rails and the cabling conduits. In addition, there are two diagonally positioned drilled holes in the back of the outlet housing, so that the metal outlet can be mounted directly on the surface by removing the top hat rail clip. Installation Option 2-port Metal Outlets for Industrial Applications, 60 x 65 x 121 mm (HxWxD), for the installation of two LANscape® modules, inclined, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016; WAXWSD-V0208-C001 equipped with one S1200 Module, Cat. 7 CAXFSM-00100-C001 in one S1200 Module Adapter CAXFSN-00110-C001 Assembled with S/STP1200 FutureCom™ cable CCXFCB-L0047-C001-L7 and with one MT-RJ Module LAXLSM-00101-C004 and one MT-RJ UniCam® Connector 92-051-97-P-E assembled with protected MiniZip FO industrial cable Special Cable J-VH(2ZN)H 2X1G50/125 Further Information (Left side) Closed metal outlets (Right side) Basic housing with mounted copper and fiber optic cables Corning Cable Systems FutureCom D The top hat rail clips can be assembled in four different positions, since distributor cabinets (e.g. robot or machine controls) FutureCom UD FutureCom UE Vertical top hat rail: Middle top hat rail clip, rotated 90° Hardware Horizontal top hat rail: Lower top hat rail clip Flex Wire Cable Telephone / for Patch Cord ISDN Products Horizontal top hat rail: Middle top hat rail clip Industrial Cable Horizontal top hat rail: Upper top hat rail clip FutureCom E FutureCom 10TEN FutureCom F Introduction Mounting on a Top Hat Rail (35 mm DIN rails) / On a Surface 139 4-Port Metal Outlets for Industrial Applications Application The 4-port LANscape® industrial metal outlets with integrated cable strain relief can be equipped with any LANscape fiber optic or copper modules. The outlet is suitable for harsh environmental conditions and can be mounted on a surface, as well as on a top hat rail (35 mm DIN rails). Features Integrated cable strain relief for 4 individual cables (separate mounting is possible) Metal construction suitable for harsh environmental conditions in industrial surroundings Conductive housing for shielded FutureCom™ modules Non-detachable designation label Cable diameter-independent and dust-protected cable entry Integrated grounding pin Non-detachable housing fastening screw Horizontal and vertical top hat rail mounting is possible Splice holder for 12 crimp-splice connections including excess length storage for FO pigtails and cables, can be retrofitted at any time Retrofitting and re-equipping without complete disassembly due to the two-part housing Ordering Information Order Number WAXWSD-V0408-C001 Description 4-Port Metal Outlet for Industrial Applications, 79x101x121 mm (HxWxD), Unit per Delivery 1/1 for the installation of max. 4 LANscape modules, inclined, with designation window, metal construction with integrated cable strain relief, integrated grounding pin, easy retrofitting of the optional splice tray, WAXLSD-0000-C001, anthracite, RAL 7016 * * other colors upon request 140 Corning Cable Systems 4-Port Metal Outlets for Industrial Applications Introduction Installation Option 4-port Metal Outlet for Industrial Applications, 79 x 101 x 121 mm (HxWxD), for the FutureCom F installation of max. 4 LANscape® mo- dules, inclined, with designation window, metal construction with integrated cable WAXWSD-V0408-C001 CAXFSM-00100-C001 one a S1200 module CAXFSN-00110-C001 Closed metal outlet Basic housing with mounted copper cables Basic housing with mounted copper and FO cables incl. splice tray Splice tray (rear side) with mounted splice connections one S250 module, Cat. 6 CAXESM-00100-C001 FutureCom UD FutureCom UE and with one SC duplex module LAXLSM-00201-C001 with dust protection flap for SC duplex multimode connector, beige LAXLOK-00013-C001 equipped with splice tray WAXLSD-00000-C001 incl. two stored crimp-splice .... mounted on a top hat rail Ordering Information Splice Tray for 4-Port Metal Outlets, 15x96x92 mm (HxWxD), with splice organizer for Units per Delivery 1/1 12 crimp-splice connections, separate excess length storage which support the minimum Special Cable WAXLSD-00000-C001 Description bend radius requirements for fiber optic pigtails and cables, anthracite, RAL 7016 * Further Information Order Number Industrial Cable connections of two SC pigtails * other colors upon request Corning Cable Systems Hardware Cat.7 Flex Wire Cable Telephone / for Patch Cord ISDN Products equipped with one S1200 module, FutureCom D anthracite, RAL 7016; FutureCom E FutureCom 10TEN strain relief, integrated grounding pin, 141 4-Port Metal Outlets for Industrial Applications with Security Features Description Features The LANscape® metal outlet is constructed entirely from metal and is intended for wall surface mounting or mounting in false floors. It offers space for four LANscape® fiber optic or copper modules. The outlet is especially designed for security applications. Metal construction suitable for harsh environmental conditions Cable strain relief for individual cables at cable entry in the basic housing using cable ties Connection protection and security against accidental or unauthorized access Fastening of the housing cover using a central screw, which can be protected, e.g. using a security label Excess length storage for fiber optic cable, maintaining the minimum bending radius Basic housing designed to be conductive (important when using FutureCom™ copper modules) Basic housing with mounted copper and FO cable Closed metal outlet with mounted copper and FO cables Ordering Information Order Number WAXWSD-U0407-C001 Description Metal Outlet, 4-Port 45x93x143.5 mm (HxWxD), for the installation of 4 Standard fastening shape (60 mm hole spacing) Horizontal and vertical top hat rail mounting Unit per Delivery 1/1 LANscape individual modules, straight, metal construction with integrated strain relief, patchcord protection and excess length storage for FO cables, WAXWSD-U0408-C001 red, RAL 3000 * Metal Outlet, 4-Port 45x93x143.5 mm (HxWxD), for the installation of 4 1/1 LANscape individual modules, straight, metal construction with integrated strain relief, patchcord protection and excess length storage for FO cables, anthracite, RAL 7016 * * other colors upon request 142 Corning Cable Systems Features The LANscape® metal outlet is constructed entirely from Metal construction, suitable for harsh environmental metal and is intended for wall surface mounting, raceway conditions mounting or mounting in false floors. It offers space for Cable strain relief for individual cables in the basic housing using cable ties FutureCom F four four LANscape fiber optic or copper modules. Fastening of the housing cover using a central screw Excess length storage for FO cables of max. length 0.6-1.0 m, for maintaining the minimum bending radius Basic housing designed to be conductive (important when using copper modules) Standard fastening shape (60 mm hole spacing) FutureCom D FutureCom E Horizontal and vertical top hat rail mounting WAXWSD-U0407-C002 Description Metal Outlet, 4-Port 45x93x87 mm (HxWxD), for the installation of 4 Unit per Delivery 1/1 Hardware Order Number FutureCom UD FutureCom UE Closed metal outlets with mounted copper cables Ordering Information LANscape individual modules, straight, Flex Wire Cable Telephone / for Patch Cord ISDN Products metal construction with integrated strain relief and excess length storage for FO cables, red, RAL 3000 * 45x93x87 mm (HxWxD), for the installation of 4 1/1 Industrial Cable Metal Outlet, 4-Port LANscape individual modules, straight, Special Cable metal construction with integrated strain relief and excess length storage for FO cables, Further Information WAXWSD-U0401-C002 FutureCom 10TEN Description Introduction 4-Port Metal Outlets for Industrial Applications white, RAL 9010 * * Other colors upon request Corning Cable Systems 143 Accessories for Floor Box Solutions Applications The LANscape® mounting panels for floor boxes are suitable for all fiber optic and copper modules. Description The modular system provides floor box solutions up to nine ports for floor boxes manufactured by Ackermann, Kleinhuis, Electraplan, VanGeel, OBO Bettermann and Vergokan. The cable strain relief is fixable in three different positions. Self-adhesive designation strips are available for all ports. Splicing of pigtails is possible in the floor box in combination with the protection box and a special splice tray. Features Suitable for all LANscape fiber optic or copper modules Mounting in the Ackermann GES4 Floor Box Installation Option Robust metal construction, black No additional mounting inserts required Integrated individual strain relief of each cable (regardless of the diamter) Strain relief mountable in various positions No screws necessary Integrated grounding pin Designation windows Up-gradeable with protection box for fiber optic cabling Up-gradeable with special splice trays Mounting panel for Ackermann floor boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 (outer mounting position only) or GES 8/10; WAXWSU-00600-C003 The two installation positions (3 modules each) are equipped with: three S250 modules CAXESM-00100-C001 one SC duplex module LAXLSM-00208-C001 and one blank cover WAXWSM-00108-C001 144 Corning Cable Systems Mounting Panels for Ackermann Floor Boxes Order Number WAXWSU-00600-C003 Description Mounting Panel for Ackermann Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 Units per Delivery 1/1 FutureCom F Ordering Information Introduction Accessories for Floor Box Solutions FutureCom 10TEN (outer mounting position only) or GES 8/10, for the installation of 6 LANscape modules, with integrated strain relief and six cable ties, Mounting Panel for Ackerman Floor Boxes GESR 7/10 (middle mounting position only), GES 9 1/1 FutureCom D WAXWSU-00900-C003 FutureCom E designation window, metal, black or GESR 9, for the installation of FutureCom UD FutureCom UE 9 LANscape modules, with integrated strain relief and nine cable ties, Mounting Panel for VanGeel Floor Box (IK-1 long), for the installation of 9 LANscape modules, with Units per Delivery 1/1 integrated cable strain relief and nine cable ties, Industrial Cable designation window, metal, black Special Cable WAXWSU-00900-C005 Description Further Information Order Number Flex Wire Cable Telephone / for Patch Cord ISDN Products Mounting Panels for VanGeel Floor Boxes Hardware designation window, metal, black Corning Cable Systems 145 Accessories for Floor Box Solutions Ordering Information Mounting Panels for Kleinhuis Floor Boxes Order Number WAXWSU-00900-C002 Description Mounting Panel for Kleinhuis Floor Box GR. II or GR. III (outer mounting position Units per Delivery 1/1 only in the round box), for the installation of 9 LANscape® modules, with integrated cable strain relief and nine cable ties, designation window, metal, black Mounting Panels for Electraplan Floor Boxes Order Number WAXWSU-00900-C004 Description Mounting Panel for Electraplan Floor Box KDR Q3 and KDR R3 (left, center, right), for the Units per Delivery 1/1 installation of 9 LANscape modules, with integrated cable strain relief and nine cable ties, designation window, metal, black Mounting Panels for Vergokan Floor Boxes Order Number WAXWSU-00900-C006 Description Mounting Panel for Vergokan Floor Box KDSVV (left, center, right), for the installation of 9 LANscape modules, with integrated cable strain relief and nine cable ties, designation window, metal, black 146 Corning Cable Systems Units per Delivery 1/1 Mounting Panels for OBO Bettermann Floor Boxes Order Number WAXWSU-00900-C007 Description Mounting Panel for OBO Bettermann Floor Boxes GE 12 R/5,GE 12R/10, GE 12 RK/5,GE 12RK/10, (left, center, Units per Delivery 1/1 FutureCom F Ordering Information Introduction Accessories for Floor Box Solutions FutureCom 10TEN right), for the installation of 9 LANscape® modules, with integrated cable strain relief and nine cable ties, Order Number WAXWSU-00000-C003 Description Protection Box for Ackermann Floor Boxes (GES 2, GES 4, GES 4/10, GESR4, GES 6, GES 6/10, FutureCom D Units per Delivery FutureCom UD FutureCom UE Protection Boxes for Mounting Panels FutureCom E designation window, metal, black 1/1 GESR 7/10 (only outer mounting position) or GES 8/10, with integrated Floor Boxes GESR 7/10 (only center position), GES 9 or GESR 9, Kleinhuis 1/1 Flex Wire Cable Telephone / for Patch Cord ISDN Products Protection Box for Ackermann Gr. II or Gr. III (only outer mounting position in round boxes), Elektroplan KDR Q3 or KDR R3 (left, center, right), VanGeel (IK-1 long), Vergokan KDSVV (left, center, right) and OBO Bettermann Industrial Cable GE12 R1S, GE 12 R/10, GE 12 RK/5 or GE 12 RK/10 (left, center, right), with integrated cable management, Special Cable metal, black Further Information WAXWSU-00000-C004 Hardware cable management, metal, black Corning Cable Systems 147 Accessories for Floor Box Solutions Ordering Information Protection Boxes for Mounting Panels Order Number WAXLSU-00000-C005 Description Splice Tray for Protection Box WAXWSU-00000-C003 (Ackermann GES 2, GES 4, GES 4/10, Units per Delivery 1/1 GESR 4, GES 6, GES 6/10, GESR 7/10, outer mounting position only, or GES 8/10), with splice organizer for the storage of 12 crimp-splice protectors, metal, black WAXLSU-00000-C006 Splice Tray for Protection Box WAXWSU-00000-C004 for Ackermann Floor Boxes GESR 7/10 (only center position), 1/1 GES 9 or GESR 9, Kleinhuis Gr. II or Gr. III (only outer mounting position in round boxes), Elektroplan KDR Q3 or KDR R3 (left, center, right), VanGeel (IK-1 long), Vergokan KDSVV (left, center, right) and OBO Bettermann GE12 R1S, GE 12 R/10, GE 12 RK/5 or GE 12 RK/10 (left, center, right), with splice organizer for the storage of 12 crimp-splice protectors, metal, black Mounting Panels for Ackermann Floor Boxes Features Suitable for all LANscape fiber optic or copper modules Metal construction, high-grade steel No mounting insert required Order Number WAXWSU-00100-C001 Description Mounting Panel for Ackermann Floor Boxes GESR 2, for the installation of one LANscape module, with grounding flap, metal, high-grade steel 148 Corning Cable Systems Units per Delivery 1/1 Accessories for Floor Box Solutions Mounting Panel for Ackermann Floor BoxGES 2,GES 4, GES 4/10, GESR 4, GES 6, Ges6/10, GES7/10 Units per Delivery FutureCom F WAXWSU-00600-C004 Description 1/1 (outside) or GES 8/10 for the installation of 6 LANscape® modules, Mounting Panel for Ackermann Floor Box GESR 7/10 (center), GES 9, or GESR 9, for the installation of 1/1 FutureCom D WAXWSU-00900-C001 FutureCom E high-grade steel 9 LANscape modules, FutureCom UD FutureCom UE high-grade steel Hardware Installation Option Mounting panel for Ackermann floor box GESR 2 Flex Wire Cable Telephone / for Patch Cord ISDN Products WAXWSU-00100-C001 equipped with one S1200 module CAXFSM-00100-C001 in conjunction with an adapter frame Industrial Cable CAXFSN-00110-C001 Further Information Mounting in the Ackermann Floor Box GESR 2 Special Cable Order Number FutureCom 10TEN Mounting Panels for Ackermann Floor Boxes Introduction Ordering Information Corning Cable Systems 149 Accessories for Floor Box Solutions Features Suitable for all LANscape® modules in conjunction with universal module housings (WAXWSE-V0201-C002) Robust metal construction No mounting insert required Integrated cable strain relief Rapid installation by snapping the module housings into the mounting panel No screws required Ordering Information Order Number WAXWSU-00400-C001 Description Mounting Panel for Ackermann Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 Units per Delivery 1/1 (only center position) or GES 8/10 for the installation of 2 LANscape housings (WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel WAXWSU-00600-C001 Mounting Panel for Ackermann Floor Boxes GESR 7/10 (center), GES 9, or GESR 9, for the installation 1/1 of 3 LANscape Housings (WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel WAXWSU-00600-C002 Mounting Panel for Kleinhuis Floor Box GR.II and GR.III (outside mounting position in round box), for the installation of 3 LANscape Housings (WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel 150 Corning Cable Systems 1/1 Accessories for Floor Box Solutions WAXWSU-00000-C001 Description Blank Cover Panel for unused mounting positions, suitable for Ackermann and Kleinhuis Delivery FutureCom F Order Number 1/1 FutureCom 10TEN Blank Cover Panel Introduction Ordering Information mounting panels (page 150), FutureCom D FutureCom E metal, high-grade steel Installation Options FutureCom UD FutureCom UE Mounting panel in the Kleinhuis floor box GR. III WAXWSU-00600-C002 The three installation positions are configured as follows: 1. Blank Cover WAXWSU-00000-C001 CAXCSE-V0201-C001 equipped with two S100eL modules CAXGSM-00100-C001 and one green S/FTP flex/26 patch cord CCAEGB-G4002-A030-C0 Mounting in the Kleinhuis Floor Box GR. III 3. Universal Housing WAXWSE-V0201-C002 Industrial Cable equipped with one S100eL module Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware 2. Module housings with self-closing shutters CAXGSM-00100-C001 and one gray S/FTP flex/26 patch cord CCAEGB-G1002-A020-C0 Special Cable and one MT-RJ fiber optic module Further Information LAXLSM-00101-C004 Corning Cable Systems 151 Patch Panels and Patch Panel Accessories Ordering Information Order Number WAXWSV-02400-C001 Description 19“ Patch Panel, for max. 24 LANscape® fiber optic or FutureCom™ Units per Delivery 1/1 copper modules, with integrated cable strain relief, 1 U, high-grade steel WAXWSV-02400-C002 19“ Patch Panel, for max. 24 LANscape fiber optic or FutureCom 1/1 copper modules, 1 U, high-grade steel WAXWSV-01200-C001 10“ Patch Panel, for max. 12 LANscape fiber optic or FutureCom 1/1 copper modules, with integrated cable strain relief, 1 U, high-grade steel WAXWSV-04800-C001 19“ Patch Panel, for max. 48 LANscape fiber optic or FutureCom 1/1 copper modules, with integrated cable strain relief, 3 U, high-grade steel 152 Corning Cable Systems Ordering Information Units per Delivery Description 19“ Blank Panel, to fill unused areas FutureCom F Order Number Introduction Patch Panels and Patch Panel Accessories WAXWSW-00000-C007 2U 1/1 19“ Cable Management 1/1 Panel, 1 U, high-grade steel front panel with 5 black FutureCom E 1/1 FutureCom D WAXWSW-00000-C005 1U FutureCom UD FutureCom UE WAXWSW-00000-C004 or rack, high-grade steel FutureCom 10TEN in the distribution cabinet cable management 19“ Cable Feedthough Panel, for feeding the cables into the cabinet 1/1 interior or rack, incl. edge grommeting, high-grade Special Cable Industrial Cable steel front panel Further Information WAXWSW-00000-C008 Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware brackets Corning Cable Systems 153 Patch Panels and Patch Panel Accessories Ordering Information Order Number WAXWSV-02408-C001 Description 19“ Patch Panel, for max. 24 LANscape® fiber optic or FutureCom™ Units per Delivery 1/1 copper modules, with integrated cable strain relief, 1 U, black WAXWSV-02408-C002 19“ Patch Panel, for max. 24 LANscape fiber optic or FutureCom 1/1 copper modules, 1 U, black 154 Corning Cable Systems Order Number Description 19“ Blank Panel, to fill unused areas Units per Delivery FutureCom F Ordering Information Introduction Patch Panels and Patch Panel Accessories WAXWSW-00008-C007 2U 1/1 19“ Cable Management 1/1 Panel,1 U, black front panel with 5 black FutureCom E 1/1 FutureCom D WAXWSW-00008-C005 1U FutureCom UD FutureCom UE WAXWSW-00008-C004 cabinet or rack, black FutureCom 10TEN in the distribution cable management 19“ Cable Feedthough Panel, for feeding the cables into the cabinet 1/1 interior or rack, incl. edge grommeting, black Special Cable Industrial Cable front panel Further Information WAXWSW-00008-C008 Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware brackets Corning Cable Systems 155 Patch Panels and Patch Panel Accessories Ordering Information Designation Labels for Patch Panels Order Number Description Delivery WAXWSW-00000-C002 440 mm Designation Window, 1/1 WAXWSW-00000-C003 DIN A4 Designation Label Sheet, 1/1 Description Units per Delivery Dust Protection Plug Order Number TKE:1304010 156 self-adhesive for LANscape® patch panels with 20 title strips for LANscape patch panels, white Dust Protection Plug for RJ45 Modules, gray Corning Cable Systems 1/100 Consolidation Point Housings for LANscape® Modules Introduction Features Full metal housing for up to 12 LANscape® fiber optic or copper modules Conforms to standards ISO/IEC 11801 (2002) and FutureCom F EN 50173-1 (2003) Ideally suited for a distribution or consolidation point Suitable for ceiling, wall, false floor or desk mounting FutureCom 10TEN Individual strain relief for incoming and outgoing cables Dust-proof feedthrough for incoming cables Easy plug-in of consolidation point cables (dust protection and mechanical protection) FutureCom E Housing floor electrically conductive for optimal shielding transition or grounding Installation height of 60 mm FutureCom D Fastening of the housing top with non-detachable screws Consolidation Point Housing for max. 12 LANscape modules, Units per Delivery 1/1 with cable strain relief for incoming data Flex Wire Cable Telephone / for Patch Cord ISDN Products cable, patch cord strain relief and dust protection flap for floor, wall and ceiling mounting, 60 x 263 x 320 mm Industrial Cable (HxWxD) Special Cable WAXWSW-00008-C015 Description Further Information Order Number Hardware Ordering Information FutureCom UD FutureCom UE Black sheet steel housing top, RAL 9005, white labeling Corning Cable Systems 157 Tools and Accessories Description The installation of FutureCom™ modules is even easier and quicker with special tools. These high-quality tools are available together in a practical toolkit, as well as individually. The use of parallel pliers to terminate the IDC-contacts of the FutureCom F S1200 modules is strongly recommended (see page 160). Ordering Information Order Number CAXCSN-00000-C005 Description Assembly Toolkit for FutureCom Modules 1 4 5 13 158 Units per Delivery 1/1 2 6 7 8 3 9 14 Corning Cable Systems 10 11 12 15 Application Assembly of additional cable strain relief for S100e, S100eL and S250 Modules 2. Module Tool Assembly of the basic modules with wire management for S10TEN, S100e, S100eL and S250 Modules 3. S1200 Installation Tool Tool for stripping cable, trimming PiMF foil and preparing the pairs of S1200 5. Screwdriver for Cross Slotted Screws, Size 1 Universal 7. Electronics Edge-Cutter, 125 mm 8. Waterproof Pen, white 9. Waterproof Pen, black 10. Telephone Scissors, 130 mm 11. Open-Ended Wrench, size 8 x 10 12. Tape Measure, 1.4 m long 13. Copper Conducting Tape, 12.7 mm wide, 16.5 m 14. Steel Ruler, 300 mm long Universal Universal Marking Marking Universal Hexagon head bolts/nuts, size 8 x 10 Universal Module installation (terminating braid shield) Universal Cutting cable sheath 15. “Jokari” Stripping Knife Special Cable 16.5 m 1/1 Industrial Cable Copper Conducting Tape, 12.7 mm wide, Units per Delivery Further Information CAXCSN-00000-C004 Description Flex Wire Cable Telephone / for Patch Cord ISDN Products Ordering Information Hardware Assembly of S1200/S250/S250fx/U250/U250fx/S100eL/S100e/U100e Modules 16. Installation Instructions Order Number FutureCom E 6. Edge-cutter Universal FutureCom D 4. Screwdriver for Slotted Screws, Size 4 modules or connectors FutureCom F 1. Crimping Tool FutureCom 10TEN Description FutureCom UD FutureCom UE Assembly Toolkit Contents Introduction Tools and Accessories Corning Cable Systems 159 Tools and Accessories Ordering Information Parallel Pliers for S1200 Module Assembly Order Number CAXCSN-00000-C008 S1200 Assembly Tool CAXFSN-00000-C001 160 Description Comfort Wide-Jawed Parallel Pliers, for terminating IDC contacts on FutureCom™ S1200 Modules S1200 Assembly Tool, for S1200 modules and S1200/4- or S1200/2 connectors Corning Cable Systems Units per Delivery 1/1 1/1 Tools and Accessories CAXCSN-00000-C007 Description Assembly Tool, for connecting the basic modules Units per Delivery FutureCom F Order Number 1/1 FutureCom 10TEN Assembly Tool for Modules Introduction Ordering Information with the wire management for FutureCom™ S10TEN, FutureCom E S10TEN fx, S250, S250fx, U250, U250fx, S100eL, Crimping Pliers for die assembly of the additional cable strain relief for the FutureCom™ S10TEN,S10TEN fx, Units per Delivery 1/1 Flex Wire Cable Telephone / for Patch Cord ISDN Products S250, S250fx, U250, U250fx, S100eL, Industrial Cable S100e, U100e modules Special Cable CAXCSN-00000-C002 Description Further Information Order Number Hardware Crimping Pliers for Additional Strain Relief FutureCom UD FutureCom UE FutureCom D S100e, U100e modules Corning Cable Systems 161 IDC Terminal Strips 1000 RT Description Corning Cable Systems IDC terminal strips provide a reliable Features and effective wire connection for telecommunications and data networks at very high density. Our strips can be mounted in 19“ panels or IDC blocks, for direct connectorization, with punch down tool. The IDC terminal strips offer a very high density with a height of only 13.8 mm including wire guides. They are easy to install and maintain. Userfriendly cable management supports longterm control over changing jumpering. High density User-friendly cable managment through wire guides High felxibility due to adaptability of different wire guides Multiple access wire guiding of incoming wires (e.g. system cable to be terminated on upper row of IDC contacts) is possible from either rear or left or right hand side. Multiple access wire guiding of outgoing wires (to be terminated on lower row of IDC contacts) is possible from either left or right hand side All combinations possible and available on request Suitable for conductor size AWG 22-28 Ordering Information IDC Disconnection Terminal Strips Order Number C39104-A123-A10 C39104-A123-A11 C39104-A123-A12 C39104-A123-A13 Description Units per Delivery numbered, white 10 pairs numbered, white 10 pairs Cable side from the right, jumper side from the left numbered, white numbered, white IDC Switching Terminal Strips C39104-A123-A40 numbered, blue C39104-A123-A43 numbered, blue C39104-A123-A41 C39104-A123-A42 162 numbered, blue numbered, blue 10 pairs 10 pairs 10 pairs 10 pairs 10 pairs 10 pairs Corning Cable Systems IDC Terminal Strip 1000RT 19“ Rack Ordering Information Description Units per Delivery C39393-A80-D53 Horizontal 19“ Rack (empty) for Series 1000RT IDC terminal strips, 1 * different sizes of mounting and full cablinet frames also available Overvoltage / Overcurrent Terminal Strips Protection S30264-D1006-S211 Overvoltage (3-point) 230 V + 20 %, with fail safe Overvoltage / Overcurrent (5-Point), 230 V + 20 %, with fail safe, 150 mA / PTC * single pair protector also available Terminal Strips Patchcords C39195-A332-A12 C39195-A332-A31 C39195-A332-A30 Patch cord 1 x 1000RT to 1 x 1000RT, 2 meters Patch cord 1 x 1000RT to 1 x RJ45, 2 meters Patch cord 2 x 1000RT to 1 x RJ45, 2 meters Disconnection & Blind Plugs, Tools and Labeling 1 1 1 1 C39334-A117-A3 Disconnection plug for 1 wire, color brown 1 C39104-A115-C50 Color black 10 caps C39104-A115-C53 Color red C39334-A117-A7 Blind plug for 1 wire, color red Marking Accessories C39104-A115-C51 C39104-A115-C52 C39104-A115-C54 C39104-A115-C55 C39104-A115-C56 C39104-A115-C57 Termination Tools C39407-A139-A12 C39407-A149-A15 Labeling Kits C39104-A123-D1 C39104-A123-D7 Color white FutureCom 10TEN 1 1 10 caps Color gray 10 caps Color blue 10 caps Flex Wire Cable Telephone / for Patch Cord ISDN Products S30264-D1006-S210 1 FutureCom E 4 pcs. required to install 20 terminal strips FutureCom D 20-way mounting frames with closed jumper comb (length = 321 mm), FutureCom UD FutureCom UE separately 1 Hardware 2 pcs. required, mounting frames and IDC terminal strips ordered 10 caps Color green 10 caps Color yellow 10 caps Color purple 10 caps Termination Tool for connecting the wires, cutting device with lock for optional cutting of excess wire length and extraction hook for removing wires Extraction Tool for removing modules out of extremely narrow distribution enclosures Industrial Cable C39104-A123-B69 Horizontal 19“ bracket to install Series 1000RT mounting frames, 1 1 Special Cable C39393-A80-D52 IDC terminal strips ordered separately (max. 28 terminal strips; 280 pairs) Further Information 19“ Solutions FutureCom F Order Number 10 pairs 100 pairs, 1 ...100 200 pairs, 1 ...200 10 pairs Corning Cable Systems Introduction IDC Terminal Strips 1000RT 163 164 Corning Cable Systems Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN Telephone / ISDN Products 9.1. Cat. 3 / ISDN Telephone Patch Panels 9.2. Telephone Patch Cords 168 Corning Cable Systems 165 Introduction 166 FutureCom F 9 Further Information Table of contents Cat. 3/ISDN Patch Panels and Telephone Patch Cords Features 19“ patch panel 1U with 50 unshielded 8-pin RJ 45 jacks Wire connection via 4-pin LSA/110 connect dual cutting clamps for AWG 22-26 Wiring according to ISO/IEC 11801/EN 50173-1, configuration: Pin 3/6 and Pin 4/5 Grounding via M6 screw with nut and lock washer on the patch panel Shield connection directly on the circuit board Integrated cable strain relief Ordering Information Order Number CAXCSV-05003-C001 Description FutureCom™ Cat. 3/ISDN Telephone Patch Panel, unshielded, 50xRJ45, Units per Delivery 1/1 configuration 4.5 and 3.6, LSA-PLUS, 1U, light-basic, RAL 7035 CAXCSV-05000-C001 FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 50xRJ45, 1/1 configuration 4.5 and 3.6, LSA-PLUS, 1U, high-grade steel 166 Corning Cable Systems Cat. 3/ISDN Patch Panels and Telephone Patch Cords Introduction Features 19“ patch panel 1U and 0.5U with 25 unshielded 8-pin RJ 45 jacks Wire connection via 8-pin LSA/110 connect dual cutting FutureCom F clamps for AWG 22-26 Wiring according to ISO/IEC 11801/EN 50173-1, configuration: Pin 3/6 and Pin 4/5 FutureCom 10TEN Grounding via M6 screw with nut and lock washer on the patch panel Shield connection directly on the circuit board CAXCSV-02503-C001 Description FutureCom™ Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45, FutureCom D Order Number Units per Delivery 1/1 FutureCom UD FutureCom UE Ordering Information FutureCom E Integrated cable strain relief configuration 4.5 and 3.6, LSA-PLUS, 1U, FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45, 1/1 configuration 4.5 and Industrial Cable 3.6, LSA-PLUS, 1U, Special Cable high-grade steel Further Information CAXCSV-02500-C001 Flex Wire Flex Wire CableCable Telephone / for Patch for Patch Cord Cord ISDN Products Hardware light-basic, RAL 7035 Corning Cable Systems 167 Cat. 3/ISDN Patch Panels and Telephone Patch Cords Ordering Information Order Number CAXCSV-02503-C002 Description FutureCom™ Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45, Units per Delivery 1/1 configuration 4.5 and 3.6, LSA-PLUS, 0.5U, light-basic, RAL 7035 CAXCSV-02500-C002 FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45, 1/1 configuration 4.5 and 3.6, LSA-PLUS, 0.5U, high-grade steel U/UTP Flex PVC Telephone Patch Cords, ISDN/Analog Order Number CCACOC-A6002-A005-C0 CCACOC-A6002-A010-C0 Description ISDN Patch Cord, black, 2xRJ45 Connectors, e.g. for ISDN & analog (So, Upo, U200, U*, U2B1Q, analog a/b, a/b/c/d) CCACOC-A6002-A015-C0 0.5 m 1m 1.5 m CCACOC-A6002-A020-C0 2m CCACOC-A6002-A025-C0 2.5 m CCACOC-A6002-A030-C0 3m CCACOC-A6002-A040-C0 4m CCACOC-A6002-A050-C0 5m CCACOC-A6002-A060-C0 6m CCACOC-A6002-A100-C0 168 Length 10 m Corning Cable Systems Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN 10 Cable for Patch Cords 10.1. S/FTP Flex/26 FRNC 10.2. SF/UTP Flex/26 FRNC 172 Corning Cable Systems 169 Introduction 170 FutureCom F Table of contents FutureCom™ Patch Cord Cable S/FTP flex/26 FRNC Braided shield Halogen-free jacket, flame retardant Foil shielding (PiMF) Twisted pair PE foam-skin insulation 4 shielded pairs Copper flex wire, AWG 26 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 170 Application FutureCom™ S/FTP flex/26 patch cord cable is designed for applications up to 600 MHz and its transmission characteristics satisfy Category 7 specifications. FutureCom patch cord cables are a low-skew product, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards of Class B interference radiation (EN 55022), as well as immunitiy (EN 55024), which enables the realization of CE-compatible networks. Halogen free foam-skin material Halogen free flame retardant Dry and damp rooms 0 to +50°C -20 to +60°C >_ 30 mm >_ 40 mm Features S/FTP flex cable, specified up to 600 MHz Outstanding electrical characteristics Cat.7 flex wire cable Low skew between the pairs Suitable for IDC contacts of RJ45 connectors or S1200 modules/connetors Surface transfer impedance < 10 mV/m at 10 MHz Flame retardant according to IEC 60332-1 , Category B Unprinted AWG 26 Corning Cable Systems FutureCom™ Patch Cord Cable S/FTP flex/26 FRNC Largest resistance margin 2% Impedance Zo at 101 - 250 MHz 100 V +/- 18% (typical value) at 10 MHz Introduction Electrical Characteristics (at 20°C) >5000 MV x km FutureCom F 100 V +/- 15% 100 V +/- 25% FutureCom 10TEN 10 m V/m 43 pF/m 0.78 x c FutureCom E 4.3 ns/m 4 ns/100 m Delay skew Frequency in MHz 1 Attenuation in dB/100m * 10 2.9 Typical values dB/100m 2.9 NEXT in dB at 100 m * 80.0 Typical values in dB at 100m 96.0 PSNEXT in dB at 100 m * 77.0 Typical values in dB at 100m 93.0 ELFEXT in dB at 100 m * 80.0 Typical values in dB at 100m 95.0 PSELFEXT in dB at 100 m * 77.0 Typical values in dB at 100m 92.0 ACR in dB 93.1 8.5 7.9 80.0 96.0 77.0 93.0 74.0 93.0 71.0 90.0 88.1 20 31.25 10.8 13.5 12.1 80.0 96.0 77.0 93.0 68.0 93.0 65.0 90.0 85.2 100 300 25.2 44.3 15.2 21.7 27.8 96.0 95.0 94.0 80.0 77.0 93.0 64.1 88.0 61.1 85.0 82.5 * Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2) Ordering Information 62.5 19.5 75.1 72.5 92.0 58.1 81.0 55.1 78.0 75.5 72.4 69.4 91.0 54.0 72.0 51.0 69.0 68.8 50.0 73.3 86.0 80.0 65.3 62.3 83.0 44.5 60.0 41.5 57.0 41.7 Type designation Fire Load Zero Category Pair count (MJ/m) Halogen Color Outer [ Weight Length (mm) (kg/km) (m) Order Number S/FTP flex/26 7 5.8 S/FTP flex/26 S/FTP flex/26 S/FTP flex/26 S/FTP flex/26 S/FTP flex/26 7 4 0.43 Yes gray 7 4 0.43 Yes green 7 7 7 4 4 4 4 0.43 0.43 0.43 0.43 Yes Yes Yes Yes blue yellow red black 600 63.5 60.8 57.8 77.0 38.4 51.0 35.4 48.0 16.5 5.8 42 2000 CCXFGB-G0047-0001-L8 5.8 42 2000 CCXFGB-G0047-0004-L8 5.8 5.8 5.8 Corning Cable Systems 42 42 42 42 2000 CCXFGB-G0047-0002-L8 2000 CCXFGB-G0047-0003-L8 2000 CCXFGB-G0047-0005-L8 2000 CCXFGB-G0047-0006-L8 171 FutureCom D at >10 MHz (NVP x c) Propagation delay >_ 10 MHz FutureCom UD FutureCom UE Propagation velocity Hardware Operating capacity Flex Wire Cable Telephone / for Patch Cord ISDN Products Surface transfer impedance Industrial Cable Impedance Zo at 251 - 600 MHz Special Cable Impedance Zo at 1 - 100 MHz Further Information Insulation resistance FutureCom™ Patch Cord Cable SF/UTP flex/26 FRNC Braided shield Halogen-free jacket, flame retardant Foil shield Twisted pair PE foam-skin insulation 4 shielded pairs Copper flex wire, AWG 26 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 172 Application The FutureCom™ SF/UTP flex/26 patch cord cable is specified for applications up to 300 MHz and it´s outstanding transmission characteristics satisfy Channel D (2002) specifications. FutureCom patch cord cables are low-skew products. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. The stranded pairs are foil shielded and have a braided shield (SF/UTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Halogen free foam-skin material Halogen free flame retardant Dry and damp rooms 0 to +50°C -20 to +60°C >_ 30 mm >_ 40 mm Features SF/UTP flex cable, specified up to 300 MHz Outstanding electrical characteristics Full copper braid shield Cat. 5e flex cable Low skew between the pairs Suitable for IDC contacts, RJ45 connectors or S1200 modules/connetors Surface transfer impedance < 10 mV/m at 10 MHz Flame retardant according to IEC 60332-1, Category B Unprinted AWG 26 Corning Cable Systems FutureCom™ Patch Cord Cable SF/UTP flex/26 FRNC Largest resistance margin 3% Surface transfer impedance <100 m V/m Propagation velocity 0.74 x c Introduction Electrical Characteristics (at 20°C) >150 MV x km FutureCom F 100 V +/- 15% at 10 MHz 4.5 ns/m 10 16 20 31.25 62.5 100 Attenuation in dB/100m * 3.2 6.0 9.5 13.6 17.1 24.8 32.0 Typical values in dB at 100m 70.0 65.0 60.0 52.0 48.0 45.0 45.0 Typical values dB/100m 3.0 NEXT in dB at 100 m * 65.3 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m ELFEXT in dB at 100 m * 63.8 – Typical values in dB at 100m PSELFEXT in dB at 100 m * 60.8 – Typical values in dB at 100m ACR in dB 67.0 – 5.8 56.3 53.3 51.8 – 48.8 – 59.2 – 9.0 50.3 47.3 43.8 12.2 45.8 42.8 37.8 – – 40.8 34.8 – – 51.0 39.8 – – * Standard: Requirements for Category 5/5e flexible cable (conforms with EN-50288-2-2) Ordering Information 14.7 42.9 39.9 33.9 – 30.9 – 33.3 – 22.5 38.4 35.4 27.9 – 24.9 – 22.5 – 27.3 35.3 32.3 23.8 – 20.8 – 17.7 – Type designation Fire Load Zero Category Pair count (MJ/m) Halogen Color Outer [ Weight Length (mm) (kg/km) (m) Order Number SF/UTP flex/26 5e 5.7 SF/UTP flex/26 SF/UTP flex/26 SF/UTP flex/26 SF/UTP flex/26 5e 4 0.43 Yes grey 5e 4 0.43 Yes green 5e 5e 5e 4 4 4 4 0.43 0.43 0.43 0.43 Yes Yes Yes Yes blue yellow red black 48.3 35.0 – – – – – – – – 5.7 40 2000 CCXDGF-C0047-0001-L8 5.7 40 2000 CCXDGF-C0047-0004-L8 5.7 5.7 5.7 40 40 40 40 2000 2000 2000 2000 CCXDGF-C0047-0002-L8 CCXDGF-C0047-0003-L8 CCXDGF-C0047-0005-L8 CCXDGF-C0047-0006-L8 Further Information SF/UTP flex/26 300 – Hardware 1 Frequency in MHz FutureCom D FutureCom E 7 ns/100 m Delay skew FutureCom UD FutureCom UE at >10 MHz (NVP x c) Propagation delay >_ 10 MHz FutureCom 10TEN 48 pF/m Operating capacity Flex Wire Cable Telephone / for Patch Cord ISDN Products (typical value) Industrial Cable Impedance Zo at 1 - 100 MHz Special Cable Insulation resistance Corning Cable Systems 173 174 Corning Cable Systems Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN 11 Further Information Industrial Cable 11.1. S/FTP 600/23 PUR Cable 176 11.2. SF/UTP J-09YS (ST) CH Cable 11.3. S/FTP 600 flex/26 PUR Cable 180 Corning Cable Systems 175 Introduction 178 FutureCom F Table of contents FutureCom™ Industrial Cable S/FTP 600/23 PUR Application The FutureCom™ Industrial S/FTP 600/23 cable with polyurethane external jacket is particularly suitable for Braided shield PUR sheath Twisted pair Foil shielding (PiMF) PE foam-skin insulation Copper conductor AWG 23 4 shielded pairs Mechanical Characteristics Area/range of application Dry and Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 176 This cable is specified for applications to up 800 MHz and satisfies Category 7 specifications ISO/IEC 11801 (2002) and EN 50173-1 (2003). These cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees outstanding shielding characteristics. The cable satifies the standard for Class B interference radiation (EN 55022), as of CE-compatible networks. Halogen free Temperature range (installation) with FutureCom metal outlets for industrial networks. well as immunitiy (EN 55024), which enables the realization Conductor insulation Outer jacket industrial applications. It is recommended in conjunction Foam-skin material Polyurethane damp rooms 0 to +50°C -20 to +60°C >_ 40 mm >_ 60 mm AWG 23 Features S/FTP 600/23 PUR cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight Low skew between the pairs Halogen-free (LSZH) Flame resistant and non-corrosive Lubricant-resistant, microbe-resistant and hydrolysisresistant Corning Cable Systems FutureCom™ Industrial Cable S/FTP 600/23 PUR Unbalance to ground dB/BZL = 1000 m FutureCom F Surface transfer impedance 100 V +/- 18% 100 V +/- 25% <10 m V/m at 10 MHz FutureCom 10TEN Impedance Zo at 251 - 600 MHz 125 V +/- 20% >46 dB at 64 kHz dB/BZL = 100 m FutureCom E >40 dB at 1 MHz Unbalance to ground >20 dB at 100 MHz dB/BZL = 100 m Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz Delay skew 0.79 x c FutureCom D Unbalance to ground 4.2 ns/m 4 ns/100 m 1 Frequency in MHz 10 16 20 31.25 62.5 100 Attenuation in dB/100m* 2.0 Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 Typical values dB/100m 5.7 1.7 NEXT in dB at 100 m * 5.0 80.0 PSNEXT in dB at 100 m* Typical values in dB at 100m ELFEXT in dB at 100 m* 80.0 Typical values in dB at 100m 7.3 80.0 9.2 80.0 14.5 13.2 75.1 18.5 16.9 72.4 98.0 98.0 98.0 98.0 97.0 77.0 71.0 66.9 65.0 61.1 55.1 51.0 74.0 93.0 91.0 ACR in dB 80.0 10.1 98.0 93.0 PSELFEXT in dB at 100 m* 6.5 8.1 98.0 80.0 Typical values in dB at 100m 7.2 91.0 98.3 95.0 69.9 93.0 91.0 93.5 68.0 93.0 91.0 92.7 64.1 90.0 88.0 90.8 58.1 86.0 84.0 86.8 54.0 83.0 81.0 82.1 300 600 65.3 60.8 33.3 30.7 95.0 62.3 93.0 44.5 68.0 41.5 66.0 64.3 48.9 44.0 91.0 57.8 89.0 38.4 51.0 35.4 49.0 47.0 800 53.0 – 87.0 – 85.0 – – – – 34.0 – * Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) Type designation Industrial Cable Ordering Information Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number Industrial S/FTP 600/23 7 4P, PUR 4 0.74 Yes 154 7.7 Corning Cable Systems 64 1000 FutureCom UD FutureCom UE Impedance Zo at 101 - 250 MHz >5000 MV x km Hardware 100 V +/- 15% Impedance Zo at 0.064 MHz Flex Wire Cable Telephone / for Patch Cord ISDN Products Impedance Zo at 1 - 100 MHz Insulation resistance CCXIPB-F0047-C001-L7 177 Special Cable 1% Further Information Largest resistance margin Introduction Electrical Characteristics (at 20°C) FutureCom™ Industrial 120V Cable SF/UTP J-09YS (ST) CH Halogen-free jacket, flame retardant Star Quad Foil shielding PP foil Dummy element Application The FutureCom™ 120 V Industrial Cable is designed specifically for data and voice transmission in industrial or telecommuncations enviroments. These cables can be used as connecting cables or for direct installation in dry as well as damp rooms. Braid shield Additional wire Foam-skin insulation Copper conductor AWG 24 Mechanical Characteristics Conductor insulation Outer jacket Jacket color Installation area Temperature (installation) Polypropylene foam-skin material Halogen-free, flame retardent Yellow (RAL 1021) In dry and damp rooms -5 to +50°C Operating temperature -30 to +70°C Min. bending radius during >_ 60 mm Min. bending radius for one-time bending installation Copper conductor 178 Features Category 3 cable, specified up to 16 MHz Category 4 cable in a quad, up to 20 MHz Complete shielding with foil and copper braid shield Low skew between the pairs Halogen-free, LSZH (low smoke, zero halogen) Flame retardant according to IEC 60332-3, Category C >_ 42 mm AWG 24 Corning Cable Systems Frequency in MHz 0.772 1 4 10 16 20 Typical values in dB at 100 m, Quad 66 65.8 53.0 44.3 42.4 41.2 Typical values in dB/100 m 1.5 Typical values in dB at 100 m, Cable 61.5 1.75 58.9 3.3 47.2 4.9 40.3 6.8 36.9 7.6 34.7 End to end in different cables (2x60m) End to end in different cables (2x60m) $ 75 dB Shield attenuation (30 to 900 MHz) Operating Voltage Testing Voltage (conductor/conductor, conductor/ shielding at 50 Hz, 1 min) Ordering Information Type designation J-09YS(ST)CH 4x2x0,5 BD 120 V FutureCom D Max. attenuation at 1 MHz $ 50 dB # 19 dB/1000m $ 80 dB FutureCom UD FutureCom UE End to end in the same quad 300 Vss 800 Vss Hardware ELFEXT at 1 MHz FutureCom E $ 50 dB $ 75 dB Zero Outer[ Weight Length (kg/km) (m) Category Pair count Halogen mm Order Number 3 4 Yes 7,5 80 1000 CCXIEO-A0027-C001-L7 Flex Wire Cable Telephone / for Patch Cord ISDN Products End to end in the same quad 120 V +/- 15V Industrial Cable NEXT at 1 MHz $ 10 GV x km Special Cable Impedance Zo at 0.064 MHz Further Information Insulation resistance FutureCom 10TEN Electrical Characteristics (at 20°C) FutureCom F Electrical Characteristics (at 20°C) Introduction FutureCom™ Industrial 120V Cable SF/UTP J-09Ys (ST) CH Corning Cable Systems 179 FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7 Application Braided shield PUR jacket Foil shielding (PiMF) Twisted pair PE foam-skin insulation 4 shielded pairs Copper flex wire AWG 26 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 180 Halogen-free foam skin material Halogen free Flame retardent In dry and damp rooms 0 to +50°C -20 to +60°C >_ 30 mm >_ 40 mm AWG 26 The Industrial S-STP 600 flex cable with polyurethane jacket is specially designed for industrial use. It is specified up to 600 MHz and satisfies Category 7 standards, ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom™ cables are low skew products, i.e. the skew be- tween the individual pairs is very low. This is increasingly being requested for applications above Gigabit Ethernet. Additional features are the slim design and low weight of the cables. Each pair is individually shielded (PiMF). The stranded pairs are additionally sheathed with a braid shield (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies Class B interference radiation standards (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Features S/FTP 600 flex/26 PUR flex cable, specified up to 600 MHz Outstanding electrical characteristics Each pair is foil-shielded (PiMF) Full copper braid shield Streamlined design Lightweight Low skew between the pairs Halogen-free (LSZH) Flame resistant and non-corrosive Lubricant-, microbe- and hydrolysis resistant Unprinted Corning Cable Systems FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7 Impedance Zo at 101 - 250 MHz 100 V +/- 18% Operating capacity 43 pF/m >5000 MV x km Insulation resistance FutureCom F 100 V +/- 15% Impedance Zo at 1 - 100 MHz 100 V +/- 25% Impedance Zo at 251 - 600 MHz FutureCom 10TEN <10 m V/m at 10 MHz Surface transfer impedance 0.78 x c Propagation velocity at >10 MHz Propagation delay >_ 10 MHz 4.3 ns/m 80.0 80.0 8.5 Typical values in dB at 100m 96.0 96.0 Typical values dB/100m 2,9 NEXT in dB at 100 m * 80.0 PSNEXT in dB at 100 m* 77.0 Typical values in dB at 100m 93.0 ELFEXT in dB at 100 m* 80.0 Typical values in dB at 100m 95.0 PSELFEXT in dB at 100 m* 77.0 Typical values in dB at 100m 92.0 ACR in dB 93.1 7.9 77.0 93.0 74.0 93.0 71.0 90.0 88.1 31.25 62.5 100 300 600 65.3 60.8 12.1 15.2 21.7 27.8 50.0 96.0 96.0 95.0 94.0 86.0 10.8 77.0 93.0 68.0 93.0 65.0 90.0 85.2 * Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2) 13.5 80.0 77.0 93.0 64.1 88.0 61.1 85.0 82.5 19.5 75.1 72.5 92.0 58.1 81.0 55.1 78.0 75.5 25.2 72.4 69.4 91.0 54.0 72.0 51.0 69.0 68.8 44.3 62.3 83.0 44.5 60.0 41.5 57.0 41.7 73.3 FutureCom D 20 2.9 63.5 80.0 FutureCom UD FutureCom UE 10 Attenuation in dB/100m* 57.8 77.0 38.4 51.0 35.4 48.0 16.5 Hardware 1 Frequency in MHz FutureCom E 4 ns/100 m Delay skew Ordering Information 7 4 0.43 Yes 5.8 42 1333 CCXIHB-G0047-0007-H2 Special Cable Industrial S-STP 600flex/26 4P Outer[ Weight Length Fire Load Zero (kg/km) (m) Category Pair count (MJ/m) Halogen mm Order Number Further Information Type designation Flex Wire Cable Telephone / for Patch Cord ISDN Products 2% Industrial Cable Largest resistance margin Introduction Electrical Characteristics (at 20°C) Corning Cable Systems 181 182 Corning Cable Systems 186 12.2.2. U/UTP 100/24 190 12.3.1. Fiber Blow S/FTP 900 192 12.2.2. F/UTP 300/24 12.3. Hybrid Cable 12.3.2. Fiber Blow S/FTP 600 188 194 12.3.3. S/FTP 600/23 4P + J-VH 4G50 FRNC 196 12.4.1. Cat. 6 Star Quad S/FTP 600/22 FRNC 198 12.4. ViMF Cable 12.4.2. Star Quad U/FTP 300/23 FRNC 202 Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware 12.4.3. Star Quad U/FTP 300/23 PVC 200 FutureCom F 12.2.1. S/FTP 600/23 with Diffusion Barrier FutureCom 10TEN 12.2. Outdoor Cable FutureCom E 184 FutureCom D 12.1. F/UTP 450/23 FRNC Cable FutureCom UD FutureCom UE 12 Special Cable Introduction Table of contents Corning Cable Systems 183 FutureCom™ Cat. 6 Cable F/UTP 450/23 Application Halogen-free jacket, flame retardent Foil shielding Foil shielding Twisted pair PE foam-skin insulation Additional wire Central cross member Copper conductor AWG 23 Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor 184 Halogen-free, foam-skin material Halogen free Flame retardent In dry and damp rooms 0 to +50°C -20 to +60°C >_ 40 mm >_ 60 mm The FutureCom™ F/UTP 450/23 cable is designed for applications up to 450 MHz and exceeds all the requirements for Category 6 specifications. FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit-Ethernet. These cables have a streamlined construction and low weight. The four stranded pairs are foil shielded (F/UTP). The cable satisfies Class B interference radiation standards (EN 55022) as well as immunity (EN 55024) which enables the realization of CE-compatible networks. Features F/UTP 450/23 cable, specified up to 450 MHz Outstanding electrical characteristics Twisted pairs with 2 foil shields Low skew between the pairs Halogen-free Flame retardant according to IEC 60332-1, Category B Non-corrosive according to IEC 60754-2 and EN 50267 Low-smoke according to IEC 61034 AWG 23 Corning Cable Systems 20 64.0 57.3 54.2 52.8 ELFEXT in dB at 100 m per Standard * 66.0 Near-end crosstalk loss in DB per Standard * 66.0 PSNEXT in dB at 100 m per Standard * PSELFEXT in dB at 100 m per Standard * 64.0 ACR in dB 63.9 7.6 59.3 56.2 50.0 47.0 43.0 53.3 100 250 49.9 45.4 42.3 36.3 44.0 40.1 41.0 48.6 62.5 10.7 54.8 45.9 31.25 8.5 46.3 51.9 37.1 41.2 15.5 47.4 34.1 31.1 31.9 19.9 44.3 30.0 27.0 24.4 * Standard: Requirements for 100 m installed Category 6 cable for Class E cabling links (conforms with EN 50288-5-1) Ordering Information Yes Max. Tensile Strength Outer[ Weight Length (kg/km) (m) Order Number mm (N) 104 6.7 49 1000 CCXCDE-B0047-C001-L7 Hardware 0.76 5.3 Flex Wire Cable Telephone / for Patch Cord ISDN Products 4 19.0 Industrial Cable 6 22.0 Special Cable F/UTP 450/23 4P Fire Load Zero Category Pair count (MJ/m) Halogen 38.3 Further Information Type designation 33.0 FutureCom F 16 6.0 FutureCom 10TEN 10 2.1 FutureCom E 1 Attenuation in dB/100m per Standard * FutureCom D Frequency in MHz FutureCom UD FutureCom UE Electrical Characteristics (at 20°C) Introduction FutureCom™ Cat. 6 Cable F/UTP 450/23 Corning Cable Systems 185 FutureCom™ Cat. 7 Outdoor Cable S/FTP 600/23 with Diffusion Barrier PE sheath Layered aluminum band Braided shield Twisted pair Foil shielding (PiMF) PE foam-skin insulation Copper conductor AWG 23 FRNC interior sheath 4 shielded pairs Mechanical Characteristics Halogen free/ Area/range of application Outdoor installation Temperature range (installation) Operating temperature Min. bending radius for one-time bending Min. bending radius during installation Copper conductor The FutureCom™ S/FTP 600/23 data cable with diffusion barrier is specified up to 800 MHz. It’s transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom cables are low-skew products, i.e.the skew between the individual pairs is very low. As a result of the aluminum composite layer sheath, this cable is suitable for direct burial. The cable has a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are sheathed with a braided shield (S/FTP), which guaran- tees outstanding shielding characteristics. The cable satisfies the standard for Class B interference radiation (EN 55022), as well as immunitiy (EN 55024), which enables the realization of CE-compatible networks. Conductor insulation Outer jacket Application foam-skin material Halogen free 0 to +50°C -20 to +60°C <_ 175 mm <_ 235 mm AWG 23 Features S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight Low skew between the pairs Includes a diffusion barrier (aluminum band and PE sheath) Halogen-free (LSZH) Interior sheath flame retardant according to IEC 60332-3 and EN 50266-2-4 Interior sheath non-corrosive according to IEC 60754-2 and EN 50267 Interior sheath low smoke according to IEC 61034 Can be directly buried 186 Corning Cable Systems FutureCom™ Cat. 7 Outdoor Cable S/FTP 600/23 with Diffusion Barrier Introduction Electrical Characteristics (at 20°C) 1% > 5000 MV x km 125 V +/- 20% FutureCom F 100 V +/- 15% 100 V +/- 18% 100 V +/- 25% Impedance Zo at 251 - 600 MHz FutureCom 10TEN <10 m V/m at 10 MHz Surface transfer impedance >46 dB at 64 kHz Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m FutureCom E >40 dB at 1 MHz Unbalance to ground >20 dB at 100 MHz Unbalance to ground dB/BZL = 100 m at >10 MHz (NVP x c) Propagation delay >_ 10 MHz FutureCom D 0.79 x c Propagation velocity 4.2 ns/m 4 ns/100 m Delay skew 1 Frequency in MHz Attenuation in dB/100m * 2.0 Typical values dB/100m 1.7 NEXT in dB at 100 m * 80.0 10 5.7 5.0 16 7.2 6.5 20 31.25 8.1 10.1 7.3 9.2 62.5 14.5 13.2 100 18.5 16.9 80.0 80.0 80.0 80.0 75.1 72.4 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 Typical values in dB at 100m PSNEXT in dB at 100 m * Typical values in dB at 100m ELFEXT in dB at 100 m * 98.0 98.0 98.0 98.0 98.0 98.0 97.0 77.0 71.0 66.9 65.0 61.1 55.1 51.0 80.0 Typical values in dB at 100m 93.0 PSELFEXT in dB at 100 m * Typical values in dB at 100m 91.0 ACR in dB 98.3 74.0 93.0 91.0 95.0 69.9 93.0 91.0 93.5 68.0 64.1 93.0 90.0 91.0 88.0 92.7 90.8 58.1 86.0 84.0 86.8 54.0 83.0 81.0 82.1 300 600 65.3 60.8 33.3 30.7 95.0 62.3 93.0 44.5 68.0 41.5 66.0 64.3 48.9 44.0 91.0 57.8 89.0 38.4 51.0 35.4 49.0 47.0 800 53.0 – 87.0 – 85.0 – – – – 34.0 – * Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) S/FTP 600/23 4P Industrial Cable Ordering Information Type designation Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 7 4 2.98 Yes 400 11.7 Corning Cable Systems 126 1000 FutureCom UD FutureCom UE Impedance Zo at 101 - 250 MHz Hardware Impedance Zo at 1 - 100 MHz Flex Wire Cable Telephone / for Patch Cord ISDN Products Impedance Zo at 0.064 MHz CCXSDB-F0047-C001-L7 187 Special Cable Insulation resistance Further Information Largest resistance margin FutureCom™ Cat. 5e Outdoor Cable F/UTP 300/24 PE Foil shielding PE-outer sheath 2 wires stranded to a pair Foil shielding Additional wire PE foam-skin PE insulation Copper conductor AWG 24 Color Coding 4 shielded pairs Pair 1 White with blue rings/blue Pair 4 White with brown rings/brown Pair 2 Pair 3 White with orange rings/orange Wire insulation Halogen free Area/range of application Outdoor installation Sheath material Temperature range (in motion) PE foam-skin material PE 0 to +50°C Operating temperature -60 to +60°C Min. bending radius >50 mm Min. bending radius for one-time bending Diameter of the copper conductor 188 The FutureCom™ F/UTP 300/24 PE cable is designed for out- door applications up to 300 MHz and provides transmission performance exceeding Category 5e ISO/IEC 11801 (2002) and EN 50173-1 (2003) specifications. The improved operating temperature of up to -60°C is appropriate for the use under most adverse conditions. This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is very low. This is increasingly being requested for Gigabit Ethernet. The cable as a streamlined construction and low weight. The stranded pairs are surrounded by foils (F/UTP). The cable satisfies Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. White with green rings/green Mechanical Characteristics during installation Application >35 mm AWG 24 Features F/UTP 300/24 PE cable, specified up to 300 MHz Outdoor cable specified up to -60°C Excellent electrical characteristics Full shielding including 2 foils with additional tinned copper wire Slim design Lightweight Low skew between the pairs PE jacket Corning Cable Systems FutureCom™ Cat. 5e Outdoor Cable F/UTP 300/24 PE Introduction Electrical Characteristics (at 20°C) 2% >5000 MV x km 185 V/km Surface transfer impedance <10 m V/m at 10 MHz Unbalance to ground >40 dB at 1 MHz FutureCom F 100 V +/- 15% dB/BZL = 1000 m dB/BZL = 100 m FutureCom 10TEN >46 dB at 64 kHz Unbalance to ground dB/BZL = 100 m FutureCom E >20 dB at 100 MHz Unbalance to ground 0.74 * c Propogation velocity at >10 MHz (NVP * c) 4.5 ns/m Signal delay >10 MHz FutureCom D 7 ns/100 m Delay margin Frequency in MHz 1 NEXT in dB at 100 m to standard* 65.3 Attenuation in dB/100m according to standard* Typical values dB/100m Typical values in dB at 100m PSNEXT in dB at 100 m according to standard* Typical values in dB at 100m ELFEXT in dB at 100 m according to standard* Typical values in dB at 100m PSELFEXT in dB at 100 m according to standard* Typical values in dB at 100m ACR in dB 10 16 20 31.25 62.5 100 38.4 35.3 2.1 6.3 8.0 9.0 11.4 16.5 77.0 62.0 59.0 57.0 54.0 50.0 2.0 5.6 50.3 62.3 47.3 75.0 60.0 63.8 43.8 72.0 60.0 60.8 40.8 70.0 58.0 74.9 55.9 7.2 47.3 44.2 57.0 39.7 54.0 36.7 52.0 51.4 8.0 45.8 42.8 55.0 37.8 52.0 34.8 50.0 48.5 10.1 42.9 39.9 52.0 33.9 48.0 30.9 46.0 43.5 21.3 14.4 35.4 48.0 27.9 40.0 24.9 38.0 34.9 18.2 46.0 32.3 44.0 23.8 34.0 20.8 32.0 26.7 250 29.5 – 38.5 – 36.5 – 22.1 – 20.1 – 7.0 300 32.2 – 35.0 – 33.0 – 17.0 – 15.0 – 0.9 * Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-2-1) Ordering Information F/UTP 300/24 PE 5e 4 No -60°C 82 6,2 36 1000 Industrial Cable Std. Max Outer [ Weight Length Min. Tem- Tensile Zero Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number CCXDAE-C0047-C001-L7 Further Information Type designation FutureCom UD FutureCom UE Impedance Zo at 1 - 100 MHz Hardware DC resistance Flex Wire Cable Telephone / for Patch Cord ISDN Products Insulation resistance Special Cable Largest resistance margin Corning Cable Systems 189 FutureCom™ Cat. 5e Outdoor Cable U/UTP 100/24 PE PE-outer jacket 2 wires stranded to a pair PE foam-skin PE insulation 4 unshielded pairs Copper conductor AWG 24 Color Coding Pair 1 White with blue rings/blue Pair 4 White with brown rings/brown Pair 2 Pair 3 White with orange rings/orange White with green rings/green Mechanical Characteristics Wire insulation Halogen free Area/range of application Outdoor installation PE foam-skin material Application The FutureCom™ U/UTP 100/24 PE cables are designed for outdoor applications up to 100 MHz and provides transmission performance exceeding Category 5e ISO/IEC 11801 (2002) and EN 50173-1 (2003) specifications. The improved operating temperature of up to -60°C/-40°C is appropriate for the employment under most, even adverse, conditions. This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is very low. This is increasingly being requested for e.g. Gigabit Ethernet. The cable has a streamlined construction and low weight. The cable satisfies Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Features U/UTP 100/24 cable , specified up to 100 MHz Outdoor cable specified up to -40°C/-60°C PE Excellent electrical characteristics Operating temperature -60 to +60°C Lightweight Min. bending radius >50 mm Sheath material Temperature range (in motion) Min. bending radius for one-time bending during installation Diameter of the copper conductor 190 0 to +50°C >35 mm Core and pairs are unshielded Slim design Low skew between the pairs PE jacket AWG 24 Corning Cable Systems FutureCom™ Cat. 5e Outdoor Cable U/UTP 100/24 PE FutureCom F 45 pF/m 4.5 ns/m Signal delay >10 MHz 7 ns/100 m Delay margin Frequency in MHz 1 10 16 20 31.25 62.5 100 NEXT in dB at 100 m to standard* 65.3 50,3 47,3 45,8 42,9 38.4 35.3 Attenuation in dB/100m according to standard* 2.1 Typical values dB/100m 1.9 Typical values in dB at 100m 77.4 PSNEXT in dB at 100 m according to standard* 62.3 Typical values in dB at 100m 74.0 ELFEXT in dB at 100 m according to standard* 63.8 Typical values in dB at 100m 68.0 PSELFEXT in dB at 100 m according to standard* 60.8 Typical values in dB at 100m 66.0 ACR in dB 74.1 6.3 5.9 65.5 47.3 60.0 43.8 49.0 40.8 47.0 56.1 8.0 7.4 62.2 44.2 56.0 39.7 45.0 36.7 43.0 50.6 9.0 8.4 59.7 42.8 54.0 37.8 42.0 34.8 40.0 47.6 11.4 10.5 57.7 39.9 51.0 33.9 40.0 30.9 38.0 42.5 16.5 15.1 49.6 35.4 47.0 27.9 33.0 24.9 31.0 33.9 21.3 19.3 46.6 32.3 44.0 23.8 28.0 20.8 26.0 26.7 *Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-3-1) Ordering Information Type designation Std. Max Outer [ Weight Length Min. Tem- Tensile Zero Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number U/UTP 100/24 PE 5e 4 4 No No -40°C -60°C 82 82 5.4 5.4 28 28 1000 1000 CCXUAE-C0047-C001-L7 CCXUAE-C0047-C002-L7 Special Cable 5e Further Information U/UTP 100/24 PE FutureCom E at >10 MHz (NVP * c) FutureCom 10TEN 0.74 x c Propogation velocity FutureCom D Mutual capacity FutureCom UD FutureCom UE 100 V +/- 15% 185 V/km DC resistance Hardware Impedance Zo at 1 - 100 MHz >5000 MV x km Insulation resistance Flex Wire Cable Telephone / for Patch Cord ISDN Products 3% Industrial Cable Largest resistance margin Introduction Electrical Characteristics (at 20°C) Corning Cable Systems 191 FutureCom™ Hybrid-Cable Fiber Blow S/FTP 900/23 Braided shield Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Copper conductor AWG 23 Tube for insertion of fibers Application The FutureCom™ S/FTP 900/23 fiber blow is prepared for the subsequent insertion of up to 12 fibers (single or multimode fibers with 250 µm diameter can be inserted). Future-proof cabling, for example fiber-to-the-desk (FTTD), can be easily realized. The integrated copper data cable is specified for applications up to 1000 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are sheathed with a braided shield (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature CE-compatible networks. Halogen free foam-skin material Halogen free flame retardant Dry and damp rooms 0 to +50°C -20 to +60°C Min. bending radius >_ 100 mm installation (over flat side*) for one-time bending Min. bending radius during Copper conductor (over flat side*) >_ 100 mm Features Fiber blow S/FTP 900/23, specified up to 1000 MHz Outstanding electrical characteristics Each pair is individually shielded with foil Full copper braid shield Low skew between the pairs Prepared for the subsequent insertion of up to 12 fibers Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 AWG 23 * Max. cabling length of 90 m with 12 x 90° bends for a radius of 100 mm 192 Corning Cable Systems FutureCom™ Hybrid-Cable Fiber Blow S/FTP 900/23 100 V +/- 15% FutureCom F 125 V +/- 20% 100 V +/- 18% Impedance Zo at 101 - 250 MHz 100 V +/- 25% Impedance Zo at 251 - 600 MHz FutureCom 10TEN <10 m V/m at 10 MHz Surface transfer impedance >46 dB at 64 kHz Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m FutureCom E >40 dB at 1 MHz Unbalance to ground >20 dB at 100 MHz Unbalance to ground dB/BZL = 100 m at >10 MHz (NVP x c) Propagation delay >_ 10 MHz FutureCom D 0.79 x c Propagation velocity 4.2 ns/m 4 ns/100 m Delay skew Frequency in MHz 1 NEXT in dB 100 m * 80.0 Attenuation in dB/100m* 2.0 Typical values dB/100m 1.7 Typical values in dB at 100m 10 5.7 5.0 80.0 16 7.2 6.5 80.0 20 8.1 7.3 80.0 31.25 10.1 9.2 80.0 62.5 100 75.1 72.4 14.5 13.2 18.5 16.8 300 600 65.3 60.8 33.3 30.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 PSNEXT in dB at 100 m* Typical values in dB at 100m ELFEXT in dB at 100 m* 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 77.0 71.0 66.9 65.0 61.1 55.1 51.0 41.5 80.0 Typical values in dB at 100m 93.0 PSELFEXT in dB at 100 m* Typical values in dB at 100m 91.0 ACR in dB 98.3 74.0 93.0 91.0 95.0 69.9 93.0 91.0 93.5 68.0 93.0 91.0 92.7 64.1 90.0 88.0 90.8 58.1 86.0 84.0 86.8 54.0 83.0 81.0 83.2 44.5 68.0 66.0 66.0 48.9 42.5 92.0 57.8 90.0 38.4 51.0 35.4 49.0 49.5 900 55.0 – 86.0 – 84.0 – – 1000 59.0 – 83.0 – 81.0 – – – – – – – – 31.0 24.0 Industrial Cable * Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) Ordering Information S/FTP 900/23 4P Fiber Blow 7 4 0.6 Yes 154 7.5x16 Corning Cable Systems 118 500 Special Cable Type designation Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number WCXWDW-I0047-C001-L6 193 Further Information Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Impedance Zo at 1 - 100 MHz >5000 MV x km Insulation resistance Hardware 1% Flex Wire Cable Telephone / for Patch Cord ISDN Products Largest resistance margin Introduction Electrical Characteristics (at 20°C) FutureCom™ Hybrid-Cable Fiber Blow S/FTP 600/23 Braided shield Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Copper conductor AWG 23 Tube for insertion of fibers Application The FutureCom™ S/FTP 600/23 fiber blow is prepared for the subsequent insertion of up to 12 fibers (single or multimode fibers with 250 µm diameter can be inserted). Future-proof cabling, for example fiber-to-the-desk (FTTD), can be easily realized. The integrated copper data cable is specified for applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom cables are low-skew products, i.e. the skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are sheathed with a braided shield (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature CE-compatible networks. Halogen free foam-skin material Halogen free flame retardant Dry and damp rooms 0 to +50°C -20 to +60°C Min. bending radius >_ 100 mm installation (over flat side*) for one-time bending Min. bending radius during Copper conductor (over flat side*) >_ 100 mm Features Fiber blow S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is individually shielded with foil Full copper braid shield Low skew between the pairs Prepared for the subsequent insertion of up to 12 fibers Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 AWG 23 * Max. cabling length of 90 m with 12 x 90° bends with regard to a radius of 100 mm 194 Corning Cable Systems FutureCom™ Hybrid-Cable Fiber Blow S/FTP 600 100 V +/- 15% FutureCom F 125 V +/- 20% 100 V +/- 18% Impedance Zo at 101 - 250 MHz 100 V +/- 25% Impedance Zo at 251 - 600 MHz FutureCom 10TEN <10 m V/m at 10 MHz Surface transfer impedance >46 dB at 64 kHz Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m FutureCom E >40 dB at 1 MHz Unbalance to ground >20 dB at 100 MHz Unbalance to ground dB/BZL = 100 m at >10 MHz (NVP x c) Propagation delay >_ 10 MHz FutureCom D 0.79 x c Propagation velocity 4.2 ns/m 4 ns/100 m Delay skew Frequency in MHz 1 10 16 20 80.0 80.0 80.0 80.0 31.25 62.5 100 80.0 75.1 72.4 300 600 Attenuation in dB/100m * 2.0 33.3 48.9 Typical values in dB at 100m Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0 92.0 PSELFEXT in dB at 100 m * 77.0 Typical values dB/100m 1.7 NEXT in dB 100 m * PSNEXT in dB at 100 m * ELFEXT in dB at 100 m * Typical values in dB at 100m ACR in dB 7.2 5.0 6.5 8.1 7.3 10.1 9.2 14.5 13.2 18.5 16.8 30.0 65.3 80.0 74.0 69.9 68.0 64.1 58.1 54.0 44.5 91.0 91.0 91.0 91.0 88.0 84.0 81.0 66.0 93.0 Typical values in dB at 100m 5.7 98.3 93.0 93.0 71.0 66.9 95.0 93.5 93.0 65.0 92.7 90.0 61.1 90.8 86.0 55.1 86.8 83.0 51.0 83.2 68.0 41.5 66.0 42.5 60.8 57.8 90.0 38.4 51.0 35.4 49.0 49.5 800 53.0 – 87.0 – 85.0 – – – – 34.0 – * Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) S/FTP 600/23 4P Fiber Blow Max Outer [Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 7 4 0.6 Yes 154 7.5x16 118 Corning Cable Systems 500 Special Cable Type designation Industrial Cable Ordering Information WCXWDW-F0047-C001-L6 195 Further Information Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Impedance Zo at 1 - 100 MHz >5000 MV x km Insulation resistance Hardware 1% Flex Wire Cable Telephone / for Patch Cord ISDN Products Largest resistance margin Introduction Electrical Characteristics (at 20°C) FutureCom™ Hybrid Cable S/FTP 600/23 4P + J-VH 4G50 FRNC Braided shield Halogen-free jacket, flame retardant Twisted pair Foil shielding (PiMF) 4 shielded pairs PE foam-skin insulation Copper conductor AWG 23 Halogen-free jacket, flame retardant Rip-cord 900 µm tight buffered fiber Fiber Strain relief (aramide yarn) Application LANscape® Hybrid cables enable the simultaneous installa- tion of a fiber optic and copper data cable. Corning fiber optic multifiber interior cables (MIC) are par- ticularly suitable for installation into cable conduits or ducts (both vertically and horizontally), false floors, as jumpers or adapter cables and for connecting workstations inside buildings (FTTD - Fiber-to-the-Desk). They can also be used as inter-building connecting cables in dry conduits. The 900µm tight-buffer design allows easy and direct field connectorization. The FutureCom™ S/FTP 600/23 copper cable is specified for applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). A high level of system performance for the complete channel is achieved by using this high-quality Category 7 cable. The low skew between the pairs emphasizes their suitability for applications above 1 Gigabit Ethernet. Due to its out- standing shielding characteristics, the cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. Features Fiber Optic Cable FO cable with 900µm tight-buffered fibers, TB-3 construction enables easy, consistent stripping Particularly suitable for field-installable UniCam® connectors Telecordia color-coding Completely dry construction Copper Cable S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is individually shielded with foil Full copper braid shield Low skew between the pairs Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 196 Corning Cable Systems foam-skin material Outer jacket Halogen free flame retardant Area/range of application 0 to +50°C Operating temperature -20 to +60°C Min. bending radius >_ 40 mm (for 2x installation (4x2...) over flat side) (4x2...) over flat side) for one-time bending >_ 60 mm (for 2x Min. bending radius during Copper conductor AWG 23 Frequency in MHz Largest resistance margin 1% Impedance Zo at 1 - 100 MHz 100 V +/- 15% Impedance Zo at 0.064 MHz 1 10 16 100 V +/- 18% Unbalance to ground >46 dB at 64 kHz 80.0 80.0 80.0 dB/BZL = 1000 m dB/BZL = 100 m dB/BZL = 100 m at >10 MHz (NVP x c) Propagation delay >_ 10 MHz Typical values in dB at 100m >100.0 >100.0 >100.0 >100.0 5.7 NEXT in dB 100 m * PSNEXT in dB at 100 m * 5.0 77.0 Typical values in dB at 100m 77.0 98.0 ELFEXT in dB at 100 m * 98.0 80.0 Typical values in dB at 100m 74.0 93.0 PSELFEXT in dB at 100 m * * 93.0 77.0 Typical values in dB at 100m 71.0 91.0 ACR in dB 91.0 98.3 95.0 7.2 6.5 77.0 98.0 69.9 93.0 66.9 91.0 93.5 FutureCom F 0.79 x c Propagation velocity 20 8.1 7.3 80.0 77.0 98.0 68.0 93.0 65.0 91.0 92.7 31.25 62.5 80.0 75.1 10.1 9.2 >100.0 77.0 98.0 64.1 90.0 61.1 88.0 90.8 14.5 13.2 <10 m V/m at 10 MHz >20 dB at 100 MHz Unbalance to ground Delay skew 100 V +/- 25% >40 dB at 1 MHz Unbalance to ground 2.0 1.7 125 V +/- 20% Impedance Zo at 101 - 250 MHz Attenuation in dB/100m* Typical values dB/100m >5000 MV x km Insulation resistance Surface transfer impedance damp rooms Temperature range (installation) Electrical Characteristics (at 20°C) Impedance Zo at 251 - 600 MHz Dry and 100 m 4.2 ns/m 100 4 ns/100 m 18.5 16.8 72.4 >100.0 >100.0 72.5 69.4 98.0 98.0 55.1 51.0 58.1 86.0 84.0 86.8 FutureCom 10TEN Halogen free 0.8 10 Gbit/s FutureCom E Conductor insulation 600 m 1 Gbit/s FutureCom D Mechanical Characteristics 0.7 1300 nm FutureCom UD FutureCom UE 2.5 2.7 850 nm 1300 nm 54.0 83.0 81.0 83.2 300 600 65.3 60.8 33.3 30.0 96.0 62.3 94.0 44.5 68.0 41.5 66.0 66.0 48.9 42.5 92.0 57.8 90.0 38.4 51.0 35.4 49.0 49.5 800 53.0 – 87.0 – 85.0 – – – – 34.0 WCXWXW-X0087-C001-L6 – *Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1) Type designation J-VH 4G50L/125 + S/FTP 600/23 FRNC Pair/fiber Category count 7 4/4 Max Outer [ Weight Length Tensile Fire Load Zero Order Number (MJ/m) Halogen Strength (N)(mm) (kg/km) (m) 1.44 Yes 154 7.5x15.5 110 Corning Cable Systems 500 Special Cable Ordering Information Hardware InfiniCor® OM2 (50 µm) 850 nm Guaranteed minimum distance at Industrial Cable Features Typ. attenuation in the tight buffer cable in dB/km Further Information Fiber Type Typ. attenuation Loose Tube Cables Flex Wire Cable Telephone / for Patch Cord ISDN Products Fiber Specification - Laser-Optimized InfiniCor® Multimode Fibers Introduction FutureCom™ Hybrid Cable S/FTP 600/23 4P + J-VH 4G50 FRNC 197 FutureCom™ ViMF Cat.6 Cable (Star Quad) S/FTP 600/22 FRNC Application The FutureCom™ StarQuad ViMF Cable is designed for applications in industrial and other harsh environments up Braided shield Halogen-free jacket, flame retardant Foil shielding 1 twisted quad PE foam-skin insulation Copper conductor AWG 22 PP foil Mechanical Characteristics Conductor insulation Outer jacket Area/range of application Temperature range (installation) Operating temperature Halogen free foam-skin material Halogen free flame retardant Dry and damp rooms skew between the individual pairs of foursomes is very low. This is increasingly required for applications above 1 Gigabit Ethernet. The cable has a streamlined construction and low weight. StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications (ISDN, Ethernet and Token Ring), the cables are suitable for systems with high frequency areas, such as TPDDI via copper S/FTP 600/22 cable, specified up to 600 MHz Outstanding electrical characteristics Each StarQuad (foursome) is shielded (ViMF) Different color coding of individual foursomes Simultaneous, standard-conforming transmission of multiple services is possible Very robust, thus particularly suitable for application in -5 to +50°C industrial and other harsh environments (over flat side*) Halogen-free (LSZH) -20 to +60°C (over flat side*) 198 FutureCom ViMF Cables are zero-skew products, i.e. the Features installation Copper conductor EN 50173-1 (2003). 1000 Base-T. >_ 26 mm Min. bending radius during 6 specifications according to ISO/IEC 11801 (2002) and (TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to Min. bending radius for one-time bending to 600 MHz. Its transmission characteristics satisfy Category >_ 40 mm AWG 22 Full copper braid shield Zero skew between the foursomes Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 Corning Cable Systems FutureCom™ ViMF Cat.6 Cable (Star Quad) S/FTP 600/22 FRNC 100 V +/- 15% FutureCom F 125 V +/- 20% <10 m V/m at 10 MHz Surface transfer impedance dB/BZL = 1000 m FutureCom 10TEN >46 dB at 64 kHz Unbalance to ground >40 dB at 1 MHz Unbalance to ground dB/BZL = 100 m Greatest possible loop resistance 130 V/km FutureCom E 48 pF/m Operating capacity 0.74 x c Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 4.9 ns/m FutureCom D 0 ns/100 m Delay skew 1 Frequency in MHz 10 16 20 31.25 62.5 100 250 Attenuation in dB/100 m * 2.1 6.0 7.6 8.5 10.8 15.5 19.9 33.0 Typical values in dB at 100 m (pair/pair) 78.6 67.5 64.0 62.0 59.0 54.5 51.8 45.0 Typical values dB/100m 1.5 NEXT in dB at 100 m * 66.0 Typical values in dB at 100 m (foursome/foursome) 90.0 PSNEXT in dB at 100 m * 64.0 Typical values in dB at 100m 75.6 ELFEXT in dB at 100 m * 66.0 Typical values in dB at 100m 75.0 PSELFEXT in dB at 100m * 64.0 Typical values in dB at 100m 73.0 ACR in dB 77.1 4.9 59.3 90.0 57.3 64.5 50.0 65.0 47.0 63.0 62.6 6.3 56.2 90.0 54.2 61.0 45.9 62.0 43.0 60.0 57.7 7.1 54.8 90.0 52.8 59.0 44.0 60.0 41.0 58.0 54.9 9.0 51.9 90.0 49.9 56.0 40.1 54.0 37.1 52.0 50.0 12.9 47.4 90.0 45.4 51.5 34.1 44.0 31.1 42.0 41.6 16.5 44.3 90.0 42.3 48.8 30.0 36.0 27.0 34.0 35.3 26.9 38.3 75.0 36.3 42.0 22.0 17.0 19.0 15.0 18.1 600 43.6 – 38.0 – 70.0 35.0 – – – – – * Standard: Requirements for 100 m installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1) Industrial Cable – Ordering Information S/FTP 600/22 ViMF 6 2 0.89 Yes 179 5.2x8.3 75 Corning Cable Systems 1000 Special Cable Type designation Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number CCXSCD-F0027-C001-L7 199 Further Information Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Impedance Zo at 1 - 100 MHz >5000 MV x km Insulation resistance Hardware 1% Flex Wire Cable Telephone / for Patch Cord ISDN Products Largest resistance margin Introduction Electrical Characteristics (at 20°C) FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 FRNC Foil shielding Halogen-free jacket Foil shielding 1 twisted quad Additional wire PE insulation Copper conductor AWG 23 PP foil Application The FutureCom™ StarQuad ViMF Cable is designed for applications in industrial and other harsh environments up to 300 MHz and its transmission characteristics satisfy Category 5 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom ViMF Cables are zero-skew products. i.e. the skew between the individual pairs of foursomes is very low. This is increasingly required for Gigabit-Ethernet. StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications (ISDN, Ethernet and Token Ring), the cables are suitable for high frequency transmission, such as TPDDI via copper (TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to 1000 Base-T. Features U/FTP 300/23 cable, specified up to 300 MHz Outstanding electrical characteristics Each StarQuad (foursome) is shielded (ViMF) Simultaneous, standard-conforming transmission of multiple services is possible Very robust, thus particularly suitable for application in industrial and other harsh environments Full shielding including one PP foil and 2 aluminum-clad foils Zero skew between the foursomes Halogen-free (LSZH) Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034 Available in 2, 3, 4 and 7 foursomes 200 Corning Cable Systems FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 FRNC Temperature range (installation) Operating temperature Min. bending radius for one-time bending damp rooms 0 to +50°C -20 to +60°C 2V: >_ 30 mm (flat side) 3V: >_ 50 mm 4V: >_ 52 mm 7V: >_ 65 mm Min. bending radius during 2V: >_ 45 mm (flat side) 3V: >_ 75 mm installation 4V: >_ 78 mm 7V: >_ 100 mm Copper conductor AWG 23 1 Frequency in MHz dB/BZL = 1000 m Unbalance to ground dB/BZL = 100 m Greatest possible loop resistance Operating capacity Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 16 20 31.25 >40 dB at 1 MHz 130 V/km 48 pF/m 0.68 x c 4.9 ns/m 0 ns/100 m Delay skew 10 62.5 100 Attenuation in dB/100 m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3 Typical values in dB at 100 m (pair/pair) 80.0 64.0 61.0 60.0 56.0 50.5 47.0 Typical values dB/100m 1.8 NEXT in dB at 100 m * 65.3 Typical values in dB at 100 m (foursome/foursome) 90.0 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 76.7 ELFEXT in dB at 100 m according * 63.8 Typical values in dB at 100m 75.0 PSELFEXT in dB at 100m according * 60.8 Typical values in dB at 100m 73.0 ACR in dB 78.2 5.2 50.3 90.0 47.3 61.1 43.8 64.0 40.8 62.0 58.8 6.7 47.2 90.0 44.2 57.8 39.7 61.0 36.7 59.0 54.3 7.5 45.8 90.0 42.8 56.9 37.8 59.0 34.8 57.0 52.5 9.4 42.9 90.0 39.9 52.8 33.9 53.0 30.9 51.0 46.6 Introduction <10 m V/m at 10 MHz >46 dB at 64 kHz Unbalance to ground 13.7 38.4 90.0 35.4 47.5 27.9 47.0 24.9 45.0 36.8 17.6 35.3 90.0 32.3 44.0 23.8 43.0 20.8 41.0 29.4 200 300 41.0 38.3 25.1 – – 80.0 38.0 – 32.0 – 30.0 – 15.9 30.9 – 80.0 35.3 – 22.0 – 20.0 – 7.4 *Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1) Type designation U/FTP 300/23 3V 5 U/FTP 300/23 2V U/FTP 300/23 4V U/FTP 300/23 7V 5 2 0.89 Yes 110 5.6x9.6 79 5 7 3.28 Yes 390 13.2 5 3 4 1.71 1.95 Yes Yes 165 220 10.1 10.4 Corning Cable Systems 105 125 219 Industrial Cable Ordering Information Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 1000 CCXSDC-C0022-C001-L7 1000 CCXSDC-C0072-C001-L7 500 500 FutureCom F Dry and 100 V +/- 15% Surface transfer impedance FutureCom 10TEN Area/range of application Impedance Zo at 1 - 100 MHz FutureCom E flame retardant 125 V +/- 20% Impedance Zo at 0.064 MHz FutureCom D Halogen free >5000 MV x km Insulation resistance FutureCom UD FutureCom UE Outer jacket 2% Hardware foam-skin material Largest resistance margin Flex Wire Cable Telephone / for Patch Cord ISDN Products Halogen free CCXSDC-C0032-C001-L6 CCXSDC-C0042-C001-L6 201 Special Cable Conductor insulation Electrical Characteristics (at 20°C) Further Information Mechanical Characteristics FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 PVC Foil shielding Schirmfolie PVC jacket Mantel PVC Foil shielding Schirmfolie Additional wire Beidraht twisted quad 41 Adern zum Vierer verseilt PE insulation PE-Isolierung Copper conductor AWG 23 Kupferleiter AWG 23 PP foil Application The FutureCom™ StarQuad ViMF cable is designed for applications in industrial and other harsh environments up to 300 MHz and its transmission characteristics satisfy Category 5 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). FutureCom ViMF cables are zero-skew products, i.e. the skew between the individual pairs of foursomes is very low. This is increasingly required for Gigabit-Ethernet. StarQuad ViMF cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications (ISDN, Ethernet and Token Ring), the cables are suitable for high frequency transmissions, such as TPDDI via copper (TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to 1000 Base-T. Features U/FTP 300/23 cable, specified up to 300 MHz Outstanding electrical characteristics Each StarQuad (foursome) is shielded (ViMF) Simultaneous, standard-conforming transmission of multiple services is possible Very robust, thus particularly suitable for application in industrial and other harsh environments suitable Full shielding including one PP foil and 2 aluminum-clad foils Zero skew between the foursomes PVC jacket Flame retardant according to IEC 60332-1, Category B Available in 1, 2, 3, and 4 foursomes 202 Corning Cable Systems Temperature range (installation) Operating temperature Min. bending radius for one-time bending damp rooms -20 to +60°C 1V: >_ 30 mm 3V: >_ 50 mm 4V: >_ 52 mm 1V: >_ 45 mm installation 2V: >_ 45 mm (flat side) 3V: >_ 75 mm 4V: >_ 78 mm Copper conductor >46 dB at 64 kHz <10 m V/m at 10 MHz dB/BZL = 1000 m 0 to +50°C 2V: >_ 30 mm (flat side) Min. bending radius during Unbalance to ground AWG 23 1 Frequency in MHz Unbalance to ground dB/BZL = 100 m Greatest possible loop resistance Operating capacity Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz 16 20 31.25 130 V/km 48 pF/m 0.68 x c 4.9 ns/m 0 ns/100 m Delay skew 10 >40 dB at 1 MHz 62.5 100 Attenuation in dB/100 m * 2.1 6.3 8.0 9.0 11.4 16.5 21.3 Typical values in dB at 100 m (pair/pair) 80.0 64.0 61.0 60.0 56.0 50.5 47.0 Typical values dB/100m 1.8 NEXT in dB at 100 m * 65.3 Typical values in dB at 100 m (foursome/foursome) 90.0 PSNEXT in dB at 100 m * 62.3 Typical values in dB at 100m 76.7 ELFEXT in dB at 100 m * 63.8 Typical values in dB at 100m 75.0 PSELFEXT in dB at 100m * 60.8 Typical values in dB at 100m 73.0 ACR in dB 78.2 5.2 50.3 90.0 47.3 61.1 43.8 64.0 40.8 62.0 58.8 6.7 47.2 90.0 44.2 57.8 39.7 61.0 36.7 59.0 54.3 7.5 45.8 90.0 42.8 56.9 37.8 59.0 34.8 57.0 52.5 9.4 42.9 90.0 39.9 52.8 33.9 53.0 30.9 51.0 46.6 13.7 38.4 90.0 35.4 47.5 27.9 47.0 24.9 45.0 36.8 17.6 35.3 90.0 32.3 44.0 23.8 43.0 20.8 41.0 29.4 200 25.1 – 41.0 – 80.0 38.0 – 32.0 – 30.0 – 15.9 300 30.9 – 38.3 – 80.0 35.3 – 22.0 – 20.0 – 7.4 *Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1) Type designation U/FTP 300/23 2V 5 U/FTP 300/23 1V U/FTP 300/23 3V U/FTP 300/23 4V Industrial Cable Ordering Information Std. Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 5 1 0.65 No 55 5.5 39 1000 CCXSKC-C0012-C001-L7 5 4 2.00 No 220 10.4 125 500 CCXSKC-C0042-C001-L6 5 2 3 1.23 1.71 No No 110 165 5.5x9.4 76 10.1 Corning Cable Systems 105 1000 500 FutureCom F Dry and Surface transfer impedance FutureCom 10TEN Area/range of application 100 V +/- 15% Impedance Zo at 1 - 100 MHz FutureCom E flame retardant 125 V +/- 20% FutureCom D Halogen free Impedance Zo at 0.064 MHz FutureCom UD FutureCom UE Outer jacket > 5000 MV x km Insulation resistance Hardware foam-skin material 2% Largest resistance margin Flex Wire Cable Telephone / for Patch Cord ISDN Products Halogen free CCXSKC-C0022-C001-L7 CCXSKC-C0032-C001-L6 203 Special Cable Conductor insulation Electrical Characteristics (at 20°C) Further Information Mechanical Characteristics Introduction FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 PVC 204 Corning Cable Systems Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E 13 Further Information 13.1. Training 206 13.2. EWP 13.3. Glossary 209 13.4. Type Codes 13.5. Product Index 211 212 Corning Cable Systems 205 FutureCom F Introduction 207 FutureCom 10TEN Table of contents LANscape® Training Training: Expertise for Your Employees Total communication solutions are becoming increasingly important for communication networks, in particular local area networks (LANs) because the future lies in the convergence of voice, video and data. Around the globe, as infor- mation infrastructures evolve, so the demands on the quality of networked communication solutions continue to grow. Meeting these demands calls for knowledge - knowledge that we can pass on to you. Techniques and products are subject to constant change. This makes it essential to have highly trained employees who know how to exploit technical progress to your advantage. This can only be achieved with continuous training. As a leading provider of communication cables, hardware and services, we are working with our customers to build communication highways for the future. We realize that the planning, installation and maintenance of cable systems calls for comprehensive technical knowledge - something we want to share with you in spirit of genuine partnership. For more Information about LANscape® Training: On the Internet: http://www.corning.com/cablesystems We Train – You Benefit Our worldwide knowledge in cable and network technology is channeled to our Training Center. It is from this knowledge base that we develop a wide range of seminars for your employees. Our training is aimed at all organizations involved in constructing or operating cable systems in the private networks or carrier area. By undertaking training before starting on a project, you can avoid costly installation errors, and take a decisive step towards ensuring a successful outcome to your project. Practical Orientation – Not Just Theory The balance between the two is critical: theory is necessary, but practice dictates what is done. From many years of practical experience, our trainers know which knowledge and skills are required for each task, and they are in constant contact with development, sales and project engineering teams at Corning Cable Systems. Our Training Centers are located in Berlin and Neustadt / Coburg, Germany. Standard and customized courses to meet Or via E-Mail: individual requirements are held locally throughout the world, where the technical facilities permit. [email protected] Or by phone under: Freephone: 00800 2676 4641 Detailed training information is available on request. Course Portfolio Private Networks: LANscape® Certified Approved Installer Courses for Structured Premises Cabling LANscape® Copper Approved Installer LANscape® Copper Approved Installer – Refresher LANscape® Fiber Optic Approved Installer LANscape® Fiber Optic Approved Installer - Refresher 206 Corning Cable Systems LANscape® Cabling Solutions: A Name You Can Trust Introduction Meeting and Exceeding Global Standards We guarantee that each customized Corning Cable Systems LANscape® Cabling Solution meets or exceeds the global FutureCom F data communication and performance standards. You can and trained. Each partner-company meets our stringent requirements for technical experience, financial strength and proven dedication to quality. EWP partners must demonstrate ongoing products withstand rigorous field and laboratory testing with continual design enhancements in response to rapidly evolving customer environments. Ready for Your Growing Network Corning Cable Systems understands the critical need for flexible solutions with the rapid growth of your data communications requirements. With Corning Cable Systems’ LANscape® Solutions, changes and expansions are cost- effective and simple. Your cost-of-ownership is minimized! Expert Service and Support Corning Cable Systems’ experts support and assist Extended Warranty Program installers with the planning, designing, and installing of fiber optic and high-end copper cabling systems.. With world-wide distribution channels and a high class Customer Service Center, Corning Cable Systems makes it easy for EWP installers to quickly get products to your site for installation. Highly trained sales consultants located in your area are available for on-site evaluations and cabling recommendations. Special Cable update training at least once every two years. systems to the customer. Corning Cable Systems LANscape® Further Information commitment to extensive training and are required to The LANscape® end to end product offering is designed to FutureCom E deliver the most technologically advanced communications Corning Cable Systems’ network of LANscape® Extended FutureCom D Warranty Program™ (EWP) installers are carefully selected FutureCom UD FutureCom UE LANscape® Solutions Total Package Hardware Installation Expertise and Reliability Flex Wire Cable Telephone / for Patch Cord ISDN Products ISO/IEC 11801 and EN 50173 (Europe). Industrial Cable ures up to the international cabling requirements, FutureCom 10TEN be assured that your Corning Cable Systems Solution meas- Corning Cable Systems 207 LANscape® Solutions: A Name You Can Trust Extended Warranty – Extra Value Corning Cable Systems’ LANscape® Extended Warranty protects your LANscape Fiber Optic and/or High-end Copper Solution for a full 25 years*. The warranty covers total sys- tem performance as well as each product component of the Corning Cable Systems’ solution. Corning Cable Systems Total Corporate Assurance EWP 25-year system warranty is offered when all products in rily on fiber cabling solutions while also offering high-end guarantees to repair or replace defective products for 25 years after installation by an EWP Partner. The LANscape® the cabling solution (cables, connectivity, and interconnect- ing hardware) are Corning Cable Systems products installed by an EWP Partner. Corning Cable Systems is the only company focusing primacopper solutions. Our mission is to remain the world’s leading developer and manufacturer of fiber optic and high-end copper products for voice, data, and video applications. Corning Cable Systems’ resources for research and product development, financial strength, and mature business focus are clearly unmatched in the communications industry. Corning is the inventor of the first commercial optical fibers and the world leader in optical fiber manufacturing for over 25 years. Our unique heritage makes Corning Cable Systems the one company that can offer a solid corporate foundation, a tradition of quality, and a name you can trust. How You Benefit LANscape® 25 years warranty Installation by Corning Cable Systems Approved partners Partners trained on the latest technology Corning Cable Systems total quality *The Extended Warranty of Corning Cable Systems is subject to the terms and conditions set forth in the EWP Contract to be signed by each EWP Partner and set forth in the Warranty Statement granted to the endcustomer of an installation. The liability of Corning Cable Systems for failures /malfunction or alterations of the specifications published at the date of installation is repair or replacement of the defective product. Corning Cable Systems shall not be liable for any consequential damages or violation of the contract terms with respect to the warranty obligation for this product. The maximum liability of Corning Cable Systems within the scope of the Extended Warranty Program is repair and replacement of the Corning Cable Systems product that does not comply with the Corning Cable Systems specifications published at the date of installation of such product plus labor costs in connection with the replacement or the repair of such products amounting to a maximum of Euro 10.000 (ten thousand). 208 Corning Cable Systems Cable sheath Capacitance unbalance Characteristic impedance Conductor Conductor resistance Corrosive DC loop resistance Delay skew Dielectric ELFEXT FEXT Fire rating Flame retardant Frequency FRNC Impedance Insulation resistance packets of fixed size. ATM supports data transfer rates of from 25 to 622 Mbps (megabits per second). American designation for conductor diameter (American Wire Gauge) The totality of cabling elements in the cable and the wrapping covering all these elements. Covering, generally of polyethylene (PE), polyvinylchloride (PVC) or zero-halogen material (H), to protect the cable core against environmental influences. The difference between the ground capacitances of the two conductors. Complex quantity defining the ratio of voltages to currents in a propagating wave at every point along the line. The conductor is used for transporting the electrical charge carriers and is therefore made of electrically conducting material (metal). The conductor is usually round. Conductor resistance is determined by the quality of the copper used and the cross-section of the conductor. It increases linearly with cable length and has a determining influence on the attenuation. Release of corrosive gases and acids by the combustion of cables and lines. For indoor installations, non-corrosive cables should be used. Halogen-free cables are generally non corrosive. Overall DC resistance of the go and return conductors (unit: ?/km) The difference in time between the arrival (reception) of a data signal and subsequent related data signals. Usually expressed in nanoseconds. Insulating material, also termed dielectric medium, i.e. an electrically non-conducting material A measurement of the unwanted signal coupling from a transmitter at the near end into another pair, measured at the far end with the effects of the attenuation removed. Far-end crosstalk loss is the attenuation between the transmission circuits of a cable at the different ends of the cable. Sum of the combustion heat of all the combustible materials located in a room (unit for cables: MJ/m) Description of the behavior of products with respect to fire propagation. Enhanced flame retardancy is generally required only for indoor cables. Number of complete cycles per second (in Hz). Flame retardant (FR) and non corrosive (NC) Impedance of an electrical four-terminal network. It comprises the DC resistance and the reactance, the latter being the frequency-dependent opposition to current flow offered by inductances and capacitances. Impedance is physically determined by the dimensions of inner conductor, dielectric and shield. This is determined by the insulating material and more particularly by the nature of the insulant than by its thickness. The insulation resistance is length dependent. Corning Cable Systems FutureCom F FutureCom 10TEN Asynchronous Transfer Mode is a network technology based on transferring data in cells or FutureCom E Cable core cable in the stationary condition (unit: dB/km or dB/100m). FutureCom D AWG Known also as attenuation coefficient, it is the length related attenuation introduced by the FutureCom UD FutureCom UE ATM frequency dependent and caused mainly by resistance and the skin effect (unit: dB) Further Information Attenuation constant Hardware Reduction in electrical signal power between two defined points on a transmission path. It is cable. Flex Wire Cable Telephone / for Patch Cord ISDN Products Attenuation Crosstalk noise from other cables in a bundle of cables or from a second cable unit in a duplex Industrial Cable Attenuation-to-crosstalk ratio ANEXT Special Cable ACR Introduction Glossary 209 Glossary LAN: Local Area Network Length of lay LS0H/LSZH Mutual capacitance NEXT Propagation delay Propagation velocity PS-ACR PSANEXT PSELFEXT PSNEXT Quad Resistance unbalance Return loss Shield Shielding Skew Skin effect Smoke density Transfer impedance Twisted pair Wire 210 Local network for bit-serial transmission between interconnected, independent terminal equipments. The term LAN was introduced in order to distinguish this network from processor links (central processor unit with peripherals) operating at very high bit rates over short distances on the one hand and from publicly accessible networks operating over long distances on the other. The distance along the center axis of a cable that a cabling element advances in order to complete one full turn (360°) about this axis. Low smoke (LS) and zero halogen (0H) Effective capacitance of the line Near-end crosstalk loss is the attenuation between the transmission circuits of a cable at the same end of the cable. The time required for a signal to pass along a transmission line. The velocity of wave propagation along a transmission line. The difference between attenuation and PSNEXT. The result is referred to as “head room”. The more head room a cable or system has the more forgiving it will be with the installation errors (apart from mis-wiring). Sum of the unwanted signal coupling of crosstalk noise at the near end from external cabling pairs into an affected pair of cable. A computed sum value of the individual ELFEXT effects on each pair by the other 3 pairs. ELFEXT removes the impact of insertion loss on Far End Crosstalk. The sum of all pair combinations for crosstalk as it occurs when a signal is introduced into a communications cable, and measured at the near end to the transmitter A series of four separately insulated conductors, generally twisted together. Difference in DC resistance between two wires of a circuit (unit: ?) The difference between the power incident upon a discontinuity in a transmission system and the power reflected from the discontinuity. Structural cable element for shielding. The design of the shield depends on whether one is seeking protection against electric fields (capacitive coupling) or magnetic fields (inductive coupling) or against both. Shielding materials against magnetic fields should always have a high electrical conductivity and small inductance, which is why, in the case of conductors, copper is mostly used. Protects against electric and magnetic influence caused by emission (emitted interference) and emission (received interference). A measure of the inequality of propagation delay between two pairs in a multi-pair cable Tendency for higher frequency currents to travel near the outside surface of a conductor Measure of the smoke generated by a burning cable. For indoor installation, cables should be selected with a low smoke density (typical value: 50%). Surface transfer impedance is a measure of the effectiveness of the shielding and is defined as the ratio of the voltage along the shield of the disturbed system to the current in the disturbing system. A transmission line in which two insulated conductors are twisted together. The wire is a conductor with a surrounding insulant. The insulant can be air or other electrically non-conducting material (usually plastic). Corning Cable Systems Further Information Special Cable Industrial Cable Flex Wire Cable Telephone / for Patch Cord ISDN Products Hardware FutureCom UD FutureCom UE FutureCom D FutureCom E FutureCom 10TEN FutureCom F Introduction Type Codes for Copper Cables Corning Cable Systems 211