English - Sunbeam
Transcription
English - Sunbeam
T H E P R O F ES S I O N A L PV M OUNTI NG SYSTE M In st a lla t io n g u id e S unbeam Nova U U n iver sa l Page 4-5: : installation of a Sunbeam Universal system (solar panels facing south). S Symmetr ical Page 6-7: installation of a Sunbeam Symmetrical system (‘east-west’ configuration). Main parts Base units The base units support the system. They are available in several lengths, enabling you to vary the distance between the rows. U U S base unit M (with ‘connector’) base unit E (without ‘connector’) optional Carriers Attach the carriers to the base units to form a stable triangular base for mounting the solar panels. U S carrier Universal carrier Symmetrical south-facing ‘east-west’ Ballast racks and wind plates In addition to carrying ballast and deflecting wind, these planar elements have an important secondary function: they reinforce the system’s matrix configuration. U S ballast rack U wind plate Va ri o u s p a r ts foot end clamp mid clamp also in black also in black clamp screw short screw carriers, ballast racks, wind plates U S 2 cable clip rubber block for gravel roofs rubber mat P rep ar a t io n • Make sure the roof is empty and clean. • Make sure the delivery is complete. • Study the configuration and ballast plan, and follow it meticulously. If you deviate • Beware of parts and packaging blowing away in the wind and sharp-edged parts damaging the top layer of the roof. • Always observe adequate safety from the plan you may end up with an measures, such as placing bannisters incorrect number of parts. along the roof edge and wearing a safety • Work accurately and systematically. harness to prevent falls. • Don’t place heavy pallets directly on the • After installation, ensure that all screws roof (especially those carrying modules, and clamps are present and firmly in ballast racks or wind plates). The local place. load on the roof may become very high. C o nfi g u r a t io n and ballas t plan Every Sunbeam project plan includes a configuration and ballast plan, Sunbeam Calculator Nova which is prepared using the Sunbeam Calculator software. Project This picture shows the positions where ballast racks are needed. The sunbeam test SB-00123 v 2.13 Basisgegevens van dit veld A veldnaam 10 m dakmaten 30 x dakbedekking bitumen gebouwhoogte numbers indicate the number of tiles to be placed in the racks. Boxes 20 30 x m Hiernaast is aangegeven welke afstanden tot de dakrand gelden bij een rechthoekig tegels ballast Dakrandzones volgens Eurocode 2,0 1 met grind without numbers represent empty ballast racks used to facilitate 1 8 20 16,0 kg installation. gebouw. U bent zelf verantwoordelijk voor het bepalen en aanhouden van de dakzones. Resultaten De ballastwaarden die dit programma stuwdruk 700 aantal modules 72 oppervlak systeem 174 m2 totaalgewicht 16,2 kg/m2 druk per voet 19 kPa aangeeft zijn alleen geldig indien het N/m2 2,0 gehele systeem in zone H staat. 26,0 2832 kg It is possible to use several types of ballast tiles, allowing for a large matches the weight prescribed in the configuration and ballast plan! 1 2 3 4 5 6 7 8 9 10 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 5 1 1 1 1 1 1 1 1 1 1 6 1 1 1 1 nn 1 1 1 7 1 1 1 1 1 1 1 1 8 1 1 1 1 1 1 1 1 11 12 module + windplaat 11,770 m range of weights. Always make sure that the actual weight of the tiles positie met 1 ballastplaat cijfer = aantal tegels @ 8 kg positie met ballastplaat zonder ballast 9 10 11 12 16,640 m In this Installation guide, steps labelled with the symbol shown on the left must be carried out exactly as described in the configuration and ballast plan. Si z i ng t o o l longest side L The sizing tool enables you to place the base Adjust the sizing tool by sliding the flanges protruding form the plastic sliders up against the units at exactly the required distance from side edges of the solar panels and firmly tightening the screws at the bottom of the slider. If you each other. don’t have a solar panel at hand, you can adjust the sizing tool using a measuring tape. 3 U 1 . P l ac i n g t h e fe et a n d t h e ba se u n its U nive rsal N M or E M M Attach one foot per base unit by clicking it Place the base units on the roof in the order indicated in the configuration and ballast plan. into place at the end without connector. The Each row is terminated (at the northern end) with an additional foot. holes in the base unit line up with the catches Caution: Do not assemble the base units yet! protruding from the feet. U 2 . P l ac i n g t h e ca rri e rs 2 3/8 3 8 -1 0 Nm 1 1. Insert the connector into the next base unit Repeat this with the end block at the opposite Attach the end blocks to the base units with side. When assembling a Universal system, the short screws. Make sure that the base 2. Insert the yellow end block into the slit. until it is up against the stop. you must first carefully bend the carrier until it units are inserted all the way, and that all the 3. Push outwards to align the screw holes. assumes the correct angle. holes are aligned properly! U 3 . A l i g ni n g , s q u a ri n g a n d pla c in g th e b a lla st r a c ks < 5 Nm 4 m N 3/8 3 m 5 m A triangle with sides of 3, 4 and 5 metres always has a square angle. Ensure that the entire system is straight and squared, using tools such as a folding square or a Attach the ballast racks using the short laser, or by drawing a ‘3-4-5 triangle’. Always use the sizing tool to make sure the base units are screws. Tighten the screws firmly, but take at the correct distance from each other. care not to strip the thread. 4 U U nive rsal 4. Ballast po sit io n r e quir ing a ba lla st r a c k ( numbe r = numbe r o f t ile s) w ind pla t e 15 cm ✔ 21 cm po sit io n r e quir ing a n ✔ e mpt y ba lla st r a c k 30 cm ✔ Place the ballast. Tiles that don’t fit inside the 30 cm rack can be placed on top. This is allowed up to a peak pressure of 1000 N/m . 2 U ≤ 1 0 0 0 N /m 2 ✘ > 1 0 0 0 N /m 2 ✘ 5 . Pl a c in g s olar pane ls 3/8 8 - 10 Nm 3/8 8 - 1 0 Nm When placing a solar panel, pay attention Sunbeam Nova end clamps can be used The mid clamps ensure a 10 mm gap between to the lip at the end of the carrier, which universally for panels ranging from 30 to 50 the panels. Fit them with the long clamp prevents the solar panels from falling down mm in thickness. Fit the clamps using the long screws as well. between the carriers. clamp screws. U 6 . F in is h ing 3/8 < 5 Nm Tie cables running between panels with the Optional power-optimisers or micro-inverters, Mount the wind plates at the backside of the cable clips. Additional cable clips can be (for example SolarEdge) can be mounted on carriers. Wind plates may overlap. ordered separately. the shorter leg of the carriers using a self- Fix them in place with the short screws. drilling screw (not included). 5 S 1 . Vo e te n en li g g ers p la a tsen Symme t rical N Attach one foot per base unit by clicking it Place the base units on the roof in the order indicated in the configuration and ballast plan. into place at the end without connector. The Add feet underneath the base units at positions where ballast racks are needed (see arrows). holes in the base unit line up with the catches If it is difficult to click the feet into place, squeeze the catches slightly inwards. protruding from the feet. Each row is terminated with an additional foot. Caution: Do not assemble the base units yet! S 2 . P l ac i n g t h e ca rri e rs 2 3/8 3 8 -1 0 Nm 1 1. Insert the connector into the next base unit Repeat this with the end block at the opposite Attach the end blocks to the base units with side. Caution: makes sure that the ‘knee plate’ the short screws. Make sure that the base stays in position. units are inserted all the way, and that all the until it is up against the stop. 2. Insert the yellow end block into the slit. holes are aligned properly! 3. Push outwards to align the screw holes. S 3 . A l i g ni n g , s q u a ri n g a n d pla c in g th e b a lla st r a c ks 4 m N < 5 Nm 3/8 3 m 5 m A triangle with sides of 3, 4 and 5 metres always has a square angle. Ensure that the entire system is straight and squared, using tools such as a folding square or a Attach the ballast racks using the short laser, or by drawing a ‘3-4-5 triangle’. Always use the size tool to make sure the base units are screws. Tighten the screws firmly, but take at the correct distance from each other. care not to strip the thread. 6 S Symm e t rical 4. Ballast po sit io n r e quir ing a ba lla st r a c k ( numbe r = numbe r o f t ile s) po sit io n r e quir ing a n e mpt y ba lla st r a c k 15 cm ✔ 21 cm pa ir o f so la r pa ne ls ✔ ( e a st -w e st ) 30 cm ✔ Place the ballast. Tiles that don’t fit inside the 30 cm rack can be placed on top. This is allowed up to a peak pressure of 1000 N/m . 2 S ≤ 1 0 0 0 N /m 2 ✘ > 1 0 0 0 N /m 2 ✘ 5 . Pl a c in g s olar pane ls 3/8 8 - 10 Nm 3/8 8 - 10 Nm When placing a solar panel, pay attention Sunbeam Nova end clamps can be used The mid clamps ensure a 10 mm gap between to the lip at the end of the carrier, which universally for panels ranging from 30 to 50 the panels. Fit them with the long clamp prevents the solar panels from falling down mm in thickness. Fit the clamps using the long screws as well. between the carriers. clamp screws. S 6 . F in is h ing Tie cables running between panels with the cable clips. Additional cable clips can be ordered separately. 7 Wa r r anty Provided SUNBEAM Nova is installed and maintained according to the instructions, SUNBEAM BV guarantees the system’s mechanical stability as well as its capability to withstand wind and snow loads conform the relevant Eurocodes. The default warranty period is 10 years. All deliveries made by SUNBEAM BV are subject to the default terms and conditions, see www.sunbeam-pv.com/eng/downloads ‘SUNBEAM’ is a registered trademark. The SUNBEAM design is protected by several international patents. Manu f ac tu r e r Sunbeam BV P.C. Staalweg 60 3721 TJ Bilthoven The Netherlands [email protected] T +31 (0)30 - 43 00 333 www.sunbeam-pv.com SUNB EAM Nova In s ta lla ti on guide — 0 7 J ul y 2 0 1 6