Telemecanique Zelio Relay complementary and
Transcription
Telemecanique Zelio Relay complementary and
PlaquetteGB.QXD 26/09/01 11:19 Page 4 Telemecanique Zelio Relay complementary and easy to assemble Get more with the world’s Power & Control specialist PlaquetteGB.QXD RS 26/09/01 11:27 Page 5 interface relays ■ Compact dimensions, enabling multiplication of contacts in electrical enclosures. ■ Plug-in relay, fast and easy interchangeability. 1 or 2 C/O contacts 8 - 12 - 16 A ■ Simplicity; no adjustment required in normal use. ■ Function marking on relay. CONTACT Number & type 2 Rated current A 8 Max switching voltage DC/AC 250/400 Min switching voltage DC 5 * RSB2A081 RSB2A080 COIL Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD CONTACT Number & type 1 * Rated current A 12 Max switching voltage DC/AC 250/400 Min switching voltage DC 5 RSB1A120 1 * * Rated current A 16 Min switching voltage DC 5 RSB1A160 insert an S after the complete product reference to order the relay and + its socket : F7 P7 COIL 12 V JD Max switching voltage DC/AC 250/400 E7 230 V Rated voltage 24 V BD V DC 48 V ED 120 V 24 V FD CONTACT Number & type B7 V AC 50-60 Hz 48 V 120 V Rated power VA W 0.75 0.45 B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V Rated power VA W 0.75 0.45 P7 COIL Rated voltage 12 V 24 V JD BD RSB2A080JDS V DC 48 V ED 120 V FD 24 V B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V P7 Rated power VA W 0.75 0.45 PlaquetteGB.QXD RX 26/09/01 11:28 Page 6 miniature relays ■ Choice of number of contacts. ■ Relay conforming to international standards. ■ Adaptable to all common voltages. ■ Fast and easy “plug-in” interchangeability. 2, 3 and 4 C/O contacts 5 - 6 - 10 - 12 A ■ Adjustment by manual control; LED relay state display. ■ Simplicity; no adjustment required in normal use. CONTACT Number & type 2 Rated current A 12 Max switching voltage DC/AC 250/400 COIL Min switching LED voltage DC 5 without with RXL2A12B 1 2 Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD CONTACT Number & type 3 Rated current A 10 Max switching voltage DC/AC 250/400 4 Rated current A 6 1 Max switching voltage DC/AC 250/400 2 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD 2 Rated current A 5 1 Max switching voltage DC/AC 250/250 2 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD 4 Rated current A 5 1 RXN41G1 Max switching voltage DC/AC 250/250 F7 230 V P7 B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V Rated power VA W 1.6 0.9 P7 2 Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD CONTACT Number & type E7 Rated power VA W 1.6 0.9 COIL Min switching LED voltage DC 5 without with RXN21E1 B7 V AC 50-60 Hz 48 V 120 V Rated voltage CONTACT Number & type P7 COIL Min switching LED voltage DC 5 without with RXL4A06B F7 Rated voltage CONTACT Number & type E7 230 V COIL Min switching LED voltage DC 5 without with RXL3A10B B7 V AC 50-60 Hz 48 V 120 V Rated power VA W 1.6 0.9 B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V Rated power VA W 1.9 0.9 P7 COIL Min switching LED voltage DC 5 without with 1 2 Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V FD 24 V B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V P7 Rated power VA W 1.9 0.9 PlaquetteGB.QXD RU 26/09/01 11:29 Page 7 universal relays ■ Choice of plug type (universal/flat tags). ■ Extremely wide power range. ■ Adaptable to all common voltages. ■ Adjustment by manual control, LED relay state display. 2 and 3 C/O contacts 4 and 10 A ■ Possibility of paralleling simplifies data processing. ■ Fast and easy “plug-in” interchangeability. ■ Simplicity; no adjustment required in normal use. CONTACT Number & type 2 4 5 8 Max switching voltage DC/AC 220/250 COIL Min switching LED voltage DC 10mA 17V without with Rated voltage 12 V 24 V JD BD V DC 48 V 120 V 24 V 7 2 RUN21D2 1 2 ED FD CONTACT Number & type 3 4 5 8 6 3 1 Rated current A 10 Max switching voltage DC/AC 220/250 230 V 7 2 1 3 4 5 8 6 3 1 Max switching voltage DC/AC 220/250 2 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD 7 2 1 4 2 5 3 6 7 8 9 A 2 B Rated current A 10 1 Max switching voltage DC/AC 220/250 2 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD 3 1 4 2 5 3 6 7 8 9 B Rated current A 10 1 RUN31C2 Max switching voltage DC/AC 220/250 E7 F7 230 V P7 B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V Rated power VA W 2.3 1.2 P7 2 Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V 24 V FD CONTACT Number & type B7 V AC 50-60 Hz 48 V 120 V Rated power VA W 2.3 1.2 COIL Min switching LED voltage DC 20 without with RUN21C2 P7 Rated voltage CONTACT Number & type F7 COIL Min switching LED voltage DC 3mA 5V without with RUN33A2 E7 Rated voltage CONTACT Rated current A 4 B7 COIL Min switching LED voltage DC 10mA 17V without with RUN31A2 Number & type A V AC 50-60 Hz 48 V 120 V Rated power VA W 2.3 1.2 6 3 1 Rated current A 10 B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V Rated power VA W 3 1.5 P7 COIL Min switching DEL voltage DC 20 without with 1 2 Rated voltage 12 V 24 V JD BD V DC 48 V ED 120 V FD 24 V B7 V AC 50-60 Hz 48 V 120 V E7 F7 230 V P7 Rated power VA W 3 1.5 PlaquetteGB.QXD 26/09/01 11:30 Page 8 RUZ sockets ■ Easy integration into ■ DIN rail or panel existing equipment. mounting. ■ Cage terminal block connection. ■ Simplicity of installation and connection. ■ Conforms to international standards. ■ A range of external accessories plug ■ Highly compact directly into socket. enabling insertion of more functions in (protection module, enclosures. LED state display). TERMINAL ARRANGEMENT MODULE VOLTAGE CURRENT Coil/contact HxWxD mixed RUZ1D None mixed RUZ7D Type E2 TERMINAL ARRANGEMENT MODULE 400 VAC 10 A mixed VOLTAGE CURRENT RUZ1A RUZ7A Type E2 66.5 x 37.5 x 25 mm 400 VAC MODULE 10 A 75 x 38 x 26 mm VOLTAGE CURRENT Coil/contact mixed RUZ1A mixed RUZ7A Type E2 66.5 x 37.5 x 25 mm 400 VAC MODULE 10 A 75 x 38 x 26 mm VOLTAGE CURRENT Coil/contact mixed RUZ1C TERMINAL ARRANGEMENT RUZ1C DIMENSIONS HxWxD None 250 VAC 10 A 72 x 44 x 26 mm MODULE VOLTAGE CURRENT DIMENSIONS Coil/contact mixed DIMENSIONS HxWxD None TERMINAL ARRANGEMENT DIMENSIONS HxWxD None TERMINAL ARRANGEMENT 66.5 x 37.5 x 25 mm 75 x 38 x 26 mm Coil/contact mixed DIMENSIONS HxWxD None 250 VAC 10 A 72 x 44 x 26 mm PlaquetteGB.QXD 26/09/01 11:27 Page 1 RXZE ■ Possibility of ■ DIN rail or panel paralleling. mounting. ■ Cage terminal block ■ Simplicity of installation and connection. connection. ■ Easy integration into ■ Conforms to existing equipment. international standards. ■ A range of external ■ Highly compact enabling insertion of more functions in enclosures. TERMINAL ARRANGEMENT MODULE VOLTAGE CURRENT Coil/contact separate mixed RXZE1S108M Type E RXZE1M114 None MODULE Yes TERMINAL ARRANGEMENT mixed 75 x 27 x 61 mm VOLTAGE CURRENT DIMENSIONS Type L 300 VAC 12 A 75 x 27 x 61 mm MODULE VOLTAGE CURRENT DIMENSIONS HxWxD HxWxD RXZE1S114M Type E RXZE1M114 None TERMINAL ARRANGEMENT DIMENSIONS 10 A Coil/contact separate (protection module, LED state display). 12 A 300 VAC Coil/contact RXZE1S111M accessories plug directly into socket. HxWxD TERMINAL ARRANGEMENT separate sockets 12 A 300 VAC 75 x 27 x 61 mm 10 A MODULE VOLTAGE CURRENT DIMENSIONS RXZE1M108M Type E 300 VAC 12 A HxWxD 75 x 27 x 61 mm mixed RXZ7G Type L 250 VAC 5A 74 x 27.4 x 42 mm mixed RXZE1M114 None 300 VAC 10 A 66 x 29.5 x 29 mm MODULE VOLTAGE CURRENT DIMENSIONS RXZE1M114M Type E 300 VAC 12 A HxWxD 75 x 27 x 61 mm mixed RXZ7G Type L 250 VAC 5A 74 x 27.4 x 42 mm mixed RXZE1M114 None 300 VAC 10 A 66 x 29.5 x 29 mm Coil/contact separate TERMINAL ARRANGEMENT Coil/contact separate PlaquetteGB.QXD 26/09/01 11:21 Page 2 RSZE ■ DIN rail or panel ■ Possibility of paralleling. mounting. ■ Easy integration into ■ Cage terminal existing equipment. block connection. ■ Function marking on ■ Conforms to socket. international standards. ■ A range of external accessories plug directly into socket. ■ Simplicity of installation and connection. TERMINAL ARRANGEMENT MODULE VOLTAGE Coil/contact Yes 300 VAC separate Type E sockets (protection module, LED state display). CURRENT 12 A DIMENSIONS HxWxD 78.5 x 15.5 x 61 mm RSZE1S48M TERMINAL ARRANGEMENT MODULE VOLTAGE CURRENT Coil/contact Yes 300 VAC 12 A separate Type E DIMENSIONS HxWxD 78.5 x 15.5 x 61 mm RSZE1S35M TERMINAL ARRANGEMENT MODULE VOLTAGE CURRENT Coil/contact Yes 300 VAC 12 A separate Type E RSZE1S48M DIMENSIONS HxWxD 78.5 x 15.5 x 61 mm PlaquetteGB.QXD 26/09/01 11:20 Page 3 Accessor ies New products 2 3 1 1 1 5 . Surge Suppressor + green LED (DC) RZM 031 ... Surge Suppressor + green LED (AC) RZM 021 .. RZM 041 ... RC circuit (. RZM 040 Diode 1 2 Label RSZL300 3 Maintaining clamp RSZR215 4 Label RXZL320 5 Maintaining clamp RXZR235 according to voltage) Schneider Electric Industries S.A. 5, rue Nadar 92506 Rueil-Malmaison Cedex - France Tel: (33) 01 41 29 82 00 Fax: (33) 01 47 51 80 20 Due to evolution of standards and equipment, characteristics indicated in text and images of this document are non-contractual and confirmation should be obtained from our services. This document is printed on recycled paper Design, illustration and production : 029776 ATTR - Tel: (33) 01 43 60 91 66 08-01 FAAED101061EN © 2001 Schneider Electric S.A. All right reserved 4 Zelio Relay plug-in relays Characteristics 0 Interface relays RSB 2A080// RSB 1A120// RSB 1A160// 1 C/O 1 C/O A 2 C/O (AgNi) 8 12 16 V V VA 72 000 600 5 " 400, $ 250 2000 3000 4000 Relay type Contact characteristics Number and type of contacts Contact materials Conventional rated thermal current (Ith) Maximum operating rate In operating cycles/h For temperature 6 40°C No-load Under load Minimum Maximum Switching voltage Maximum breaking capacity Coil characteristics " $ " $ Rated voltage (Un) Average consumption Permissible voltage variation Drop-out voltage threshold V V VA W " $ 24…240, 50/60 Hz 6…110 0.75 0.45 0.8…1.1 Un (50/60 Hz or $) à 20 °C ≥ 0.15 ≥ 0.1 Un Environment Conforming to standards Approvals (pending) Ambient air temperature around the device Standard version Standard version Storage Operation Conforming to IEC 68-2-6 Vibration resistance Degree of protection Shock resistance Mechanical durability Operating time (response time) In millions of operating cycles " Between coil energisation and $ making of the On-delay contact " Between coil de-energisation and $ making of the Off-delay contact Resistive load Inductive load Electrical durability In millions of operating cycles/h IEC 61810-1 UL, CSA - 40…+ 85 $ - 40…+ 85, " - 40...+ 70 > 10 gn (10…150 Hz) °C °C ms ms IP 40 10 gn (closing), 5 gn (opening) ≥ 30 About 12 About 9 ms ms About 10 About 4 8 A - 250 V : ≥ 0.1 See curves below 16 A - 250 V : ≥ 0.07 Insulation characteristics Conforming to IEC 947 Conforming to VDE 0110 Between coil and " contact Between poles Between contacts " V V 2500 1000 Reduction coefficient (A) 107 Durability (number of operating cycles) V 400 C 250 5000 Reduction coefficient for inductive load " (depending on power factor cos ϕ) Electrical durability of the contacts Resistive load " A 106 C B 105 V 104 $ 50 1 0,8 0,6 0,5 0,4 0,8 1 1,2 1,6 2 A References : page 28041/3 28041_Ver1.00-EN.fm/2 C A 0,5 0,1 10,8 0,6 Switching capacity (kVA) A RSB 2A080// B RSB 1A160// C RSB 1A120// B 16 12 8 5 2 1 0,4 0,3 0 Maximum switching capacity on a resistive load $ current Rated insulation voltage (Ui) Insulation class Dielectric strength (rms voltage) 0,4 0,2 cos ϕ 10 20 30 50 100 200 300 Voltage $ Durability (inductive load) = durability (resistive load) x reduction coefficient. Dimensions : page 28046/2 Schemes : page 28047/2 Schneider Electric Zelio Relay plug-in relays References 0 Interface relays References 560582 Relays for standard applications Number of C/O contacts 2 1 Conventional rated thermal current Sold in lots of Unit reference, to be completed by adding the control voltage code (1) (2) A 8 12 16 10 10 10 RSB 2A080// RSB 1A120// RSB 1A160// Sold in lots of Unit reference 10 10 10 10 10 10 10 10 10 RZM 040W RZM 031RB RZM 031BN RZM 031FPD RZM 021RB RZM 021BN RZM 021FP RZM 041BN7 RZM 041FU7 Sold in lots of 10 10 Unit reference Weight kg 0.014 0.014 0.014 Protection modules Description 560583 RSB 2A080BD + RSZ E1S48M Type Diode Diode + LED E E Varistor + LED E RC circuit E Sockets - 12 A, For use with Voltage V $ $ $ $ $ or " $ or " $ or " " " 6…230 6…24 24…60 110…230 6…24 24…60 110…230 24…60 110…240 " 300 V RSB 2A080 and RSB 1A160 RSB 1A120 RSZ E1S48M RSZ E1S35M Weight kg 0.003 0.004 0.004 0.004 0.005 0.005 0.005 0.010 0.010 Weight kg 0.050 0.060 Accessories Application Sold in lots of 10 10 RSB 1A120JD + RZM 030FPD + RSZ E1S35M 560584 Maintaining clamp Legend Unit reference RSZ R215 RSZ L300 Weight kg 0.002 0.001 (1) Standard control circuit voltages Volts 6 12 24 48 60 110 120 220 230 240 $ RD JD BD ED ND FD – – – – " 50/60 Hz – – B7 E7 – – F7 M7 P7 U7 For other voltages, please consult your Regional Sales Office. (2) To order a relay complete with socket: add suffix S to the references selected above. Example: RSB 2A080// becomes RSB 2A080//S Coil characteristics Control circuit voltage Uc V 6 12 24 48 60 110 120 220 230 240 560585 RSB 1A160BD + RSZ E1S48M d.c. supply Average resistance at 20 °C ± 10% Ω 90 360 1440 5700 7500 25 200 – – – – Cod. Operating voltage limits Min Max RD JD BD ED ND FD – – – – V 4.2 8.4 16.8 33.6 42 77 – – – – V 15.3 30.6 61.2 122.4 153 280 – – – – a.c. supply, 50/60 Hz Average Cod. Operating voltage resistance limits at 20 °C Min Max ± 15 % Ω V V – – – – – – – – 400 B7 19.2 26.4 1550 E7 38.4 32.8 – – – – – – – – 10 200 F7 96 132 35 500 M7 176 242 38 500 P7 184 253 42 500 U7 192 264 RSZ 215 Characteristics : page 28041/2 Schneider Electric Dimensions : page 28046/2 Schemes : page 28047/2 28041_Ver1.00-EN.fm/3 Zelio Relay plug-in relays Characteristics 0 Miniature relays RXL 2A12B/// RXL 3A10B/// RXL 4A06B/// 3 C/O 4 C/O A 2 C/O (AgNi) 12 10 6 V V VA 18 000 1200 5 " 400, $ 250 3000 2500 1500 Relay type RXL 4G06B/// Contact characteristics Number and type of contacts Contact materials Rated conventional thermal current (Ith) Maximum operating rate In operating cycles/h Switching voltage For temperature 6 40°C No-load Under load Minimum Maximum Maximum breaking capacity AgNI/AU 0.2 µ Coil characteristics " $ " $ Rated voltage (Un) Average consumption Permissible voltage variation Drop-out voltage threshold V V VA W 24…230, 50/60 Hz 12…110 1.6 0.9 0.8…1.1 Un (50/60 Hz or $) ≥ 0.15 Un ≥ 0.1 Un " $ Environment Conforming to standards Approvals (pending) Ambient air temperature around the device Vibration resistance Degree of protection Shock resistance Mechanical durability Operating time (response time) Electrical durability In millions of operating cycles/h Standard version Standard version Storage Operation To IEC 68-2-6 In millions of operating cycles Between coil " energisation and $ making of the On-delay contact " Between coil de-energisation and $ making of the Off-delay contact Resistive load Inductive load ms ms IEC 61810-1 UL, CSA - 40…+ 85 $ - 40…+ 70, " - 40...+ 55 > 5 gn (10…150 Hz) IP 40 10 gn (closing), 5 gn (opening) ≥ 20 About 12 About 12 ms ms About 12 About 4 °C °C 12 A - 250 V: ≥ 0.1 See curves below 10 A - 250 V: ≥ 0.1 ≥ 20 6 A - 250 V: ≥ 0.1 Insulation characteristics V C 106 B 250 V 2500 V 1500 Reduction coefficient for inductive load " (depending on power factor cos ϕ) 1 0,8 2000 Maximum switching capacity on a resistive load $ $ 12 current 107 250 C 250 2500 V Reduction coefficient Conforming to IEC 947 Conforming to VDE 0110 Between coil and " contact Between poles Between contacts " Electrical durability of the contacts Resistive load " Number of operating cycles Rated insulation voltage (Ui) Insulation class Dielectric strength (rms voltage) 0,6 10 5 4 3 2 C 1 0,4 0,5 0,4 0,3 D A 0,2 A B 105 0 1 2 3 Switching capacity A RXL 4 B RXL 2 C RXL 3 References: pages 28042/4 and 28042/5 28042_Ver2.00-EN.fm/2 B 0,1 1 0,8 0,6 0,4 0,3 0,2 Cos ϕ 0 20 30 80 120 160 200 250 300 Voltage$ RXL 2, RXL 3 and RXL 4 A RXL 3 (T = 0 ms) B RXL 3 (T = 40 ms) C RXL 4 D RXL 2 Durability (inductive load) = durability (resistive load) x reduction coefficient Dimensions: page 28046/2 Schemes: page 28047/2 Schneider Electric Zelio Relay plug-in relays Characteristics (continued) 0 Miniature relays RXN 21E1/// RXN 41G1/// 4 C/O A 2 C/O AgNI 5 V V VA 7200 3600 5 400 " , 250 $ 1250 Relay type Contact characteristics Number and type of contacts Contact materials Conventional rated thermal current (Ith) Maximum operating rate In operating cycles/h Switching voltage For temperature 6 40°C No-load Under load Minimum Maximum Maximum breaking capacity 1250 Coil characteristics " $ " $ Rated voltage (Un) Average consumption Permissible voltage variation Drop-out voltage threshold V V VA W 24…230, 50/60 Hz 12…110 1.9 0.9 0.8…1.1 Un (50/60 Hz or $) ≥ 0.15 Un ≥ 0.1 Un " $ Environment Conforming to standards Approvals (pending) Ambient air temperature around the device Vibration resistance Degree of protection Shock resistance Mechanical durability Operating time (response time Electrical durability In millions of operating cycles/h Standard version Standard version Storage Operation Conforming to IEC 68-2-6 In millions of operating cycles Between coil " energisation and $ making of the On-delay contact " Between coil de-energisation and $ making of the Off-delay contacts Resistive load Inductive load IEC 61 810-1 CSA, UL - 40…+ 70 - 20…+ 50 > 5 gn (30…150 Hz) °C °C ms ms IP 40 20 gn 20 About 12 About 12 ms ms About 12 About 4 5 A / 250 V See curves below Insulation characteristics V V 2000 V 1500 Reduction coefficient for inductive load " (depending on power factor cos ϕ) 106 Maximum switching capacity on a resistive load $ $ 1 0,8 current 107 250 A 250 2000 V Reduction coefficient Conforming to IEC 947 Conforming to VDE 0110 Between coil and " contact Between poles Between contacts " Electrical durability of the contacts Resistive load " Durability (number of operating cycles) Rated insulation voltage (Ui) Insulation class Dielectric strength (rms voltage) 0,6 5 4 3 2 1 0,7 0,5 0,4 0,3 0,4 0,2 105 0,1 0 1 2 Switching capacity (kVA) 1 0,8 0,6 0,4 0,2 Cos ϕ 0 20 40 60 80 120 160 200 250 Voltage $ Durability (inductive load) = durability (resistive load) x reduction coefficient References: pages 28042/4 and 28042/5 Schneider Electric Dimensions: page 28046/2 Schemes: page 28047/2 28042_Ver2.00-EN.fm/3 Zelio Relay plug-in relays References 0 Miniature relays 560586 References Relays for standard applications (1) Number of C/O contacts Conventional rated thermal current A 5 2 12 3 10 4 5 RXN 21E12BD + RXZ E1M114 560587 6 LED Sold in lots of Unit reference, to be completed by adding the control voltage code (2) Weight Red Without Green Without Green Without Red Without Green Without 10 10 10 10 10 10 10 10 10 10 RXN 21E12// RXN 21E11// RXL 2A12B2// RXL 2A12B1// RXL 3A10B2// RXL 3A10B1// RXN 41G12// RXN 41G11// RXL 4A06B2// RXL 4A06B1// kg 0.035 0.034 0.036 0.035 0.036 0.035 0.035 0.034 0.036 0.035 10 10 RXL 4G06B1// RXL 4G06B2// 0.036 0.035 Sold in lots of Unit reference 10 RXW 040MD kg 0.010 RZM 040W RZM 031RB RZM 031BN RZM 031FPD RZM 021RB RZM 021BN RZM 021FP RZM 041BN7 RZM 041FU7 0.003 0.004 0.004 0.004 0.005 0.005 0.005 0.010 0.010 Relays with gold-flashed contacts (1) 4 6 With Without Protection modules for sockets RXZ 7G Description Diode Type Voltage L V $ 12…250 Weight Protection modules for relay/sockets RXZ E////M 560588 RXL 4A06B1BD + RXZ E1S114M Diode Diode + Green LED E Varistor + Green LED E RC circuit E $ $ $ $ $ or " $ or " $ or " " " 6…230 6…24 24…60 110…230 6…24 24…60 110…230 24…60 110…240 10 10 10 10 10 10 10 10 10 (2) Standard control circuit voltages Volts 12 24 48 $ JD BD ED " (50/60 Hz) RXN – B7 E7 RXL – B7 E7 For other voltages, please consult your Regional Sales Office . 110 FD F7 – 120 – – F7 230 – P7 P7 Coil characteristics RXL 2A12B2BD + RXZ P20 + RXZ E1S108M 560589 28042_Ver2.00-EN.fm/4 d.c. supply Average Cod. Operating voltage resistance limits at 20 °C Min Max ± 10% Ω V V a.c. supply, 50/60 Hz Average Cod. Operating voltage resistance limits at 20 °C Min Max ± 15 % Ω V V V RXN relays 12 160 JD 9.6 13.2 – – – – 24 640 BD 19.2 26.4 150 B7 19.2 26.4 48 2600 ED 38.4 52.8 635 E7 38.4 52.8 110 13 600 FD 88 121 – F7 – – 230 – – – – 15 400 P7 184 253 RXL relays 12 160 JD 9.6 13.2 – – – – 24 640 BD 19.2 26.4 158 B7 19.2 26.4 48 2600 ED 38.4 52.8 640 E7 38.4 52.8 110 13 600 FD 88 121 – – – – 120 – – – – 3770 F7 96 132 230 – – – – 16 100 P7 184 253 (1) These relays have a lockable Test button on their front face, which can be converted to nonlockable or can be eliminated, see accessories on page opposite. RXL 2A12B2BD + RZM 030RB + RXZ P10 + RXZ E1S111M Characteristics: pages 28042/2 and 28042/3 Control circuit voltage Uc Dimensions: page 28046/2 Schemes: page 28047/2 Schneider Electric References (continued) Zelio Relay plug-in relays 0 Miniature relays References Sockets (1) Protection module Application 560590 Without Type I/O RXN 21, RXN 41, L RXL 2A12 and RXL 4A06 RXN 21, RXN 41, E RXL 2, RXL 4 With 560591 RXZ 200 Unit reference Mixed Sold in lots of 10 Weight RXZ E1M114 kg 0.048 Mixed 10 RXZ 7G 0.055 RXN 21, RXL 2 E Separate 10 RXZ E1S108M 0.058 RXL 3A10 E Separate 10 RXZ E1S111M 0.065 RXN 4, RXL 4A06 E Separate 10 RXZ E1S114M 0.070 Mixed 10 RXZ E1M114M 0.070 Unit reference RXZ P20 kg 0.001 E Accessories Description RXZ R235 Application Button For non-lockable Test function Sold in lots of 20 (2) Blanking cover For elimination of Test function 20 (2) RXZ P10 0.001 Metal maintaining clamps Plastic maintaining clamps Legends For use on all sockets 10 RXZ 200 0.001 RXZ E 10 RSZ R235 0.005 Clip-in fixing on socket RXZ-7G 10 RXZ 300 0.010 Clip-in fixing on socket RXZ-7G in place of module RXW 040MD 10 RXZ 310 0.011 Clip-in fixing on socket RXZ-E 10 RSZ L320 0.001 " Weight (1) A bag containing ten RXZ 300 legends is supplied with sockets RXZ 7G. 300 V. RXZ E1M114: 7 A, RXZ 7G: 6 A, 300 V. RXZ E1S M: 12 A, 300 V. (2) 10 red and 10 green. /// Characteristics: pages 28042/2 and 28042/3 Schneider Electric Dimensions: page 28046/2 " " Schemes: page 28047/2 28042_Ver2.00-EN.fm/5 Zelio Relay plug-in relays Characteristics 0 Universal relays Relay type RUN 21C RUN 31C RUN 21D RUN 31A RUN 33D 3 C/O 2 C/O 3 C/O A 2 C/O AgNi 10 10 3 C/O linked Hard silver, 10 µ gold-flashed 4 V V VA 36 000 3600 20 "/$ 250 3000 36 000 3600 20 "/$ 250 3000 36 000 3600 10 " 250, $ 125 1000 Contact characteristics Number and type of contacts Contact materials Conventional rated thermal current (Ith) Maximum operating rate In operating cycles/h For temperature 6 40°C No-load Under load Minimum Maximum Switching voltage Maximum breaking capacity Coil characteristics Rated voltage (Un) Average consumption Inrush Sealed Permissible voltage variation Drop-out voltage threshold " $ " " $ V V VA VA W " $ 24, 48, 110, 230, 50/60 Hz (Other voltages available on request) 12, 24, 48, 110 (Other voltages available on request) 3.5 3.5 3.5 2.3 2.3 2.3 1.5 1.5 1.5 0.8…1.1 Un (50 Hz or $), 0.85…1.1 Un (60 Hz) ≥ 0.15 Un ≥ 0.15 Un ≥ 0.15 Un ≥ 0.05 Un Environment Conforming to standards Approvals (pending) Ambient air temperature around the device Standard version Standard version Storage Operation Vibration resistance Conforming to IEC EN 68-2-6 Degree of protection Shock resistance Mechanical durability Operating time (response time) " $ In millions of operating cycles " Between coil energisation and $ making of the On-delay contact " Between coil de-energisation and $ making of the Off-delay contact Resistive load Inductive load Electrical durability In millions of operating cycles/h °C °C °C EN 61810-1 UL, CSA - 40…+ 70 - 20…+ 40 - 20…+ 60 4 gn (30…100 Hz) ms ms IP 40 10 gn 20 About 15 About 15 ms ms About 15 About 15 ≥ 0.1 to 10 A See curves below Insulation characteristics Rated insulation voltage (Ui) Insulation class Dielectric strength (rms voltage) Conforming to IEC 947 Conforming to VDE 0110 Between coil and " contact Between poles Between contacts " Durability in N (230 V, 50 Hz) Durability (number of operating cycles) 10 7 V V V V 250 C250, B380 2500 2500 1000 Switching capacity on a $ supply for minimum durability of: 106 operating cycles (resistive or inductive load with diode RVW 040BD). 6 4 3 2 1,5 1 5x10 6 2x10 6 10 6 2 5x10 5 1 2x10 5 10 5 5x10 4 1 2 3 0,6 0,4 0,3 0,2 0,1 10 20 50 10 2 2x10 2 10 3 5x10 3 VA 2x10 3 0 20 60 100 140 200 Switching capacity 1 Contact 2 Contacts in series 3 Contacts in series 1 Resistive load 2 Inductive load References: page 28043/3 28043_Ver1.00-EN.fm/2 Dimensions: page 28046/3 Schemes: page 28047/3 Schneider Electric Zelio Relay plug-in relays References 0 Universal relays References 560592 Relays for standard applications Number of C/O contacts RUN 31C22// + RUZ 1C 2 Conventional rated thermal current A 10 3 10 LED Pins Sold in lots of without Octal 8 flat pins Green Octal 8 flat pins Without Undecal 11 flat pins Green Undecal 11 flat pins 10 10 10 10 10 10 10 10 Unit reference, to Weight be completed by adding the control voltage code (1) kg RUN 21D21// 0.105 RUN 21C21// ? 0.105 RUN 21D22// RUN 21C22// ? RUN 31A21// 0.105 RUN 31C21// ? RUN 31A22// 0.105 RUN 31C22// ? 10 RUN 33A22// Relays with gold-flashed contacts 3 4 Green Undecal 0.105 LED indicator modules Voltage 560593 Description Sold in lots of Unit reference 110/230 6/24 20 20 RUW 010P7 RUW 030BD kg 0.006 0.006 $ " " " 6…220 24 230 110…240 20 20 20 20 RUW 040BD RUW 042B7 RUW 042P7 RUW 041P7 0.006 0.006 0.006 0.006 7 24…240 1 RUW 101MW 0.020 Unit reference RUZ 1D RUZ 1A Weight kg 0.067 0.067 V " $ With protection diode “Power on” indication Weight Protection module Diode Varistor RC circuit Timer modules RUN 31A21// + RUZ 1A Multifunction Sockets 560594 Protection module Without With Application I/O RUN 21 octal RUN 31 and RUN 33 undecal RUN 21C and RUN 31C RUN 31 and RUN 33 RUN 21 octal Mixed Mixed Sold in lots of 10 10 Mixed 10 RUZ 1C 0.067 Mixed Mixed 10 10 RUZ 7D RUZ 7A 0.069 0.069 Sold in lots of 25 Unit reference Accessories Description RUN 33A22// + RUW 101MW + RUZ 7A Maintaining clamp (1) Standard control circuit voltages Volts 12 24 48 $ RUN 21 and RUN 31 JD BD ED RUN 33 – BD ED " 50/60 Hz RUN 21, RUN 31 – B7 E7 and RUN 33 For other voltages, please consult your Regional Sales Office. RUZ 200 110 FD – F7 Weight kg 0.001 230 – – P7 560590 Coil characteristics Control circuit voltage Uc RUZ 200 Characteristics: page 28043/2 Schneider Electric V 12 24 48 110 230 Dimensions: page 28046/3 d.c. supply Average resistance at 20 °C ± 10% Ω 96 384 1336 7660 – Cod. Operating voltage limits Min Max JD BD ED FD – V 9.6 19.2 38.4 88 – V 19.2 26.4 52.8 121 – a.c. supply, 50/60 Hz Average Cod. Operating resistance voltage limits at 20 °C Min Max ± 15 % Ω V V – – – 73.7 B7 204 26.4 305 E7 408 54.8 1710 F7 93.5 121 7500 P7 196 253 Schemes: page 28047/3 28043_Ver1.00-EN.fm/3 Zelio Relay plug-in relays Schemes 0 Interface relays RSB 1A120// 3 8 5 7 4 6 3 1 3 4 2 6 5 1 4 2 5 7 1 8 RSB 1A160// 2 RSB 2A080// When using relay RSB 1A160// with socket RSZ E1S48M, terminals 11 and 21, 14 and 24, 12 and 22 must be linked. Miniature relays RXN 21E1/// RXN 41G 1 4 1 2 3 4 12 5 42 8 12 5 22 6 32 7 42 8 14 9 44 12 14 9 24 10 34 11 44 12 11 13 41 14 11 13 21 31 41 14 A1 A2 A1 RXL 2// A2 RXL 3// RXL 4// 1 4 1 2 3 1 2 3 4 12 5 42 8 12 22 32 4 5 6 12 5 22 6 32 7 42 8 14 9 44 12 14 7 24 8 34 9 14 9 24 10 34 11 44 12 11 13 41 14 11 13 21 31 14 11 13 21 31 41 14 A1 A2 A1 A2 A1 References : pages 28041/3 et 28042/4 28047_Ver1.00-EN.fm/2 A2 Dimensions : page 28046/2 Schneider Electric Schemes (continued) Zelio Relay plug-in relays 0 Universal relays RUN 21D2/// 12 4 14 34 31 24 21 32 14 22 12 11 A2 A1 24 RUN 31A2///, RUN 33A2/// RUN 31C2/// 21 14 22 11 A2 A1 12 RUN 21D2///, RUN 21C2/// RUN 33A2/// 21 6 22 22 5 24 7 5 3 6 2 7 24 12 4 14 3 A1 + 9 34 A2 A1 1 11 8 2 + 21 RUN 21C2/// 32 8 10 A2 11 1 11 31 RUN 31C2/// 1 3 1 2 3 12 22 12 32 22 4 6 4 5 6 14 7 24 9 14 7 34 8 24 9 11 A (+) 21 B ( ) 11 A (+) 31 21 B ( ) A1 A2 A1 References : page 28043/3 Schneider Electric A2 Dimensions : page 28046/3 28047_Ver1.00-EN.fm/3 Zelio Relay plug-in relays Dimensions 0 Interface relays (References: page 28041/3) RSB 2A080//, RSB 1A160// 12,5 7,5 15,7 5 3,9 2,5 3,5 5 Sockets RSZ E1S48M 2,5 3,5 RSZ E1S35M 67 67 (4) Ø 3,2 29,4 (2) 34,5 50 Ø 3,2 (1) 75 (1) (4) 61 (3) 78,5 61 (3) 29 16,5 29,4 3,9 RSB 1A120// 29 15 12,5 7,5 15,7 (2) 34,5 50 15,5 15,5 Miniature relays (References: pages 28042/4 and 28042/5) 27,5 RXN 21E1///, RXN 41G1///,RXL 21,1 35,6 41,8 Sockets RXZ 7G RXZ E1S108M (4) 82 61 = 19 (4) 83 3,2 75 (1) = (2) 78,5 73,5 2xØ3,3 (2) (3) 22 37,4 41,5 55 RXZ E1S111M 27 RXZ E1S114M, RXZ E1M114M 82 (4) (2) 75 (3) 29 3,2 (1) 83 75 (1) (2) 22,5 55 27 (4) 61 3,2 61 83 82 (3) 22,5 29 27 29 55 22,5 27 (1) Relays, (2) Add-on protection module, (3) Maintaining clamp, (4) Legend. References: pages 28041/3 and 28042/4 28046_Ver1.00-EN.fm/2 Schemes: page 28047/2 Schneider Electric Zelio Relay plug-in relays Dimensions (continued) 0 Universal relays (References: page 28043/3) RUN 21C2/// RUN 31C2/// 24 37 37 RUN 21D2/// RUN 31A2/// RUN 33A2/// 35,5 55 35,5 59 66,5 Sockets RUZ 1D 25 = 8 29,5 3,5 29,5 3,5 22 = = 8 66,5 = RUZ 1A 37,5 = RUZ 7A = RUZ 7D 37,5 2x 3,2 = = 75 75 2x 3,2 22,5 30 22,5 30 26 38 26 38 = RUZ 1C = 72 2x 4 23 37,5 26 45 References: page 28043/3 Schneider Electric Schemes: page 28047/3 28046_Ver1.00-EN.fm/3
Similar documents
The Kalam Cosmological Argument
e'"030&"0-0#0'0f%(0'0'+g0/"'"00#0"$('"0*"d0&0 #'%'0h""30hi0jk4klk2.R'%#"30m3d'30k4no2.R3.0p
More informationGenealogy Descendants Index
Bradley, Daniel Frances Hester Lena Blanche Martha A. Bradshaw, Howard Brady, James Harry Mary V. Rosa Susan Laura Brake, Claude D. Conway G. Gene R. George John Norris C.
More information