Emergency - Acuity Brands

Transcription

Emergency - Acuity Brands
Emergency
Emergency Lighting Units
Family
FileName
Description
RevisionDate
680.193
ela-cl
ELA-IND-NX
ELA-IND-PM-CM-RHB-R3
ela-lv3
ELA-MR24
ELA-MT-WP-Z
ELA-OMC-ELA-AFNR
ela-osl
ELA-RG-SG-RR
ELA-RTLP-MS-VS2-WG
ELA-RTT-BS
ela-sb-oc-eb
UE-406
UE-510
UE-610
Exit Discharge Guide
Core lights
Industrial remotes
Indura® pendant and ceiling mounting kits/remote head bracke
Remote downlights, MR16
Adjustable remotes
Unit Accessories (ELA MT, ELA WP, ELA Z)
Outdoor Mini Cylinder and Affinity® Remote Fixture
Outdoor Step Lights
Gimbals & rectangles
Remote test switch, mounting shelf, vandal-resistant shield,
Indura remote test transmitter banding strap
Remote downlights, PAR36
Remote heads
Low-voltage remote downlight relay
Voltage Drop Tables
08/15/2003
12/20/2007
12/20/2007
08/03/2006
12/20/2007
12/17/2007
02/18/2008
12/20/2007
12/20/2007
12/17/2007
03/11/2008
12/05/2005
12/20/2007
12/17/2007
03/15/1989
06/15/1997
ELA-ZCD
ELA-ZX
Z
ZX
Class II - Division 1 Remote
Class I - Division 1 Remote
Class I - Division 2 Unit
Class I - Division 1 Unit
10/16/2007
10/16/2007
10/16/2007
12/11/2007
IND6-12-24
INDX
Indura® 6, 12 or 24V sealed lead-calcium or ni-cad battery,
Indura® 6, 12 or 24V sealed lead-calcium or ni-cad battery,
10/30/2007
09/28/2007
ELM6-12
ELM
ELM2
Quantum® high capacity unit
Quantum® 6V 12W lead-calcium, fixed optics
Quantum® 6V 12W lead-calcium, fully adjustable optics
12/17/2007
06/25/2007
06/25/2007
680.211
AFN
ELCC
ELR2-2P-4
ELRG
ELSQ-M
VEL
Guideline Specification
Architectural Emergency Light
6V-12W Lead-calcium
6V-16W and 12V-50W Lead-calcium
Dual-voltage input, 8W halogen lamp head
6V-10W and 6V-20W Lead-calcium
Concealed Emergency Lighting Unit
08/15/2003
09/28/2007
11/08/2007
12/17/2007
01/02/2008
09/28/2007
09/28/2007
125W/12V, 180W/12V, or 275W/12V lead-calcium
Titan® 16W/6V, 24W/6V, 36W/6V, or 50W/12V lead-calcium or ni
6V 24-36W Lead-calcium - Chicago approved
12/17/2007
12/17/2007
02/12/2007
Emergency Lighting Remotes
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
ELA
Hazardous Location
ELA ZCD
ELA ZX
Z
ZX
Indura® Industrial
IND
INDX
Quantum® Series Thermoplastic
ELM6-12
ELM-ELM2
ELM-ELM2
Specialty Commercial
AFN
AFN
ELCC
ELR
ELRG
ELSQ
VEL
Titan® Steel Industrial
ELT
ELT
ELT
ELT-125-180-275
ELT-16-24-36-50
UE-215
Exit Discharge Application Guide
for Normally-off Fixtures
Traditional emergency lighting and exit signs were primarily focused on guiding occupants to
the exterior of a building. Today, an additional focus is being placed on getting occupants to an
exit safely and down a path of safety once they are out of the building. This guide will help
define the exit discharge, reference code requirements for the exit discharge, and identify
products that can be applied to meet exit discharge requirements. Either normally-on or
normally-off fixtures can provide exit discharge illumination. However, this guide will only
cover normally-off remote fixtures.
Interior Normal or conditioned space
Path of egress
ExteriorDamp or wet location
Exit discharge
Exit Discharge
Description
The exit discharge is the portion of the
means of egress between the building exit
and the public way. According to the 2003
Life Safety Code, section 3.3.175, a public
way is defined as "A street, alley or other
similar parcel of land essentially open to the
outside air deeded, dedicated, or otherwise
permanently appropriated to the public for
public use and having a clear width and
height of not less than 30ft (50mm) (120in)."
Since the nature of the exit discharge is
outdoor applications, standard luminaires
may not be suitable. Outdoor applications
fall into two categories: damp location or wet
location. According to chapter one, article
100, of the 2002 National Electrical Code,
damp locations include ". . .partially protected
locations under canopies, marquees, roofed
open porches, and like locations. . ." Wet
location is partially defined as ". . .locations
subject to saturation with water or other
liquids, such as vehicle washing areas; and
in unprotected locations exposed to
weather."
See page 4 for Code information.
Sheet #: 680.193
REF - 160
Remote Fixtures
In general, remote fixtures offer advantages
such as lower initial cost, lower
maintenance costs, and better aesthetics
over typical emergency battery units. These
advantages are more prevalent in
environments that require special ratings
such as wet location and NEMA 4X, or in
areas where ambient temperatures can
diminish battery capacity or life. Both
occurances are common with the exit
discharge.
In many instances, the battery unit can be
installed in a normal or conditioned
environment with the remote heads located
in the areas that require special ratings.
The following chart lists normally-off remote
fixtures that may be used in damp or wet
locations. Please consult the Lithonia
Lighting Product Selection Guide for lamp
type, voltage, and wattage.
Description
Lamp
Wall
Mount
Architectural die-cast
Xenon
x
Recessed gimbal
PAR36
Halogen
incandescent
x
x
ELA LV3 OC
Recessed 3” adjustable
specular open cone
6V, 12V
MR16 halogen
x
x
ELA OC
Recessed 6” adjustable
specular, open clear
6V, 12V
PAR36
Halogen
incandescent
x
x
ELA LV3 SB
Recessed 3”
baffled reflector
white, 6V, 12V
MR16 Halogen
x
x
ELA SB
Recessed 6”
baffled reflector
white, 6V, 12V
PAR36
Halogen
incandescent
x
x
ELA LV3 EB
Recessed 3”
baffled eyeball
white, 6V, 12V
MR16 Halogen
x
x
ELA EB
Recessed 6”
baffled eyeball
white, 6V, 12V
PAR36
Halogen
incandescent
x
x
Recessed
outdoor step light
Die-cast aluminum, 12V
Halogen
(not MR11 or MR16)
Fixture
AFN
ELA RG
ELA OSL
ELA Core Light
ELA OMC
Recessed round,
outdoor core light,
die-cast aluminum,
6V, 12V
Surface-mount
outdoor mini cylinder
die-cast aluminum
6V, 12V
Ceiling
Mount
Wet
Damp
x
x
x
x
x
x
x
x
x
x
Cold
Weather
x
-40oC to 60oC
MR16 Halogen
MR11 Halogen
x
x
x
x
ELA QR*
Surface-mount
Q-Bic remote
4” square polycarbonate
ELA WP
Surface-mount
weatherproof
aluminum, 12V
ELA NX*
Surface-mount
wet location
sealed glass
gray, white, black
6V, 12V
PAR36
Halogen
incandescent
x
ELA Z
Surface-mount
Class 1, Div. 2
haz. location,
sealed glass, gray
6V, 12V
PAR36
Halogen
incandescent
x
Halogen
incandescent
35W, PAR46
incandescent
x
x
x
x
x
x
x
x
x
x
* These remote fixtures are offered in single and twin head versions.
Page 2
Power Sources
Once the classification of an environment is determined and the remote fixtures have been
chosen, the next step is to determine which power sources will operate the remote fixtures from
a normal or controlled environment. If a facility utilizes unit equipment for its emergency
lighting, the option of running the exit discharge remote(s) off of those units should be
considered. By utilizing the chart below, select which unit(s) will work best for the application.
Application
Commercial / Light Industrial
Commercial / Light Industrial
Commercial / Light Industrial
Industrial / Commercial
Industrial / Commercial
Industrial / Commercial
Unit
6ELM2P
ELM4
ELM10
IND6
IND12
IND24
Volts
6
12
12
6
12
24
Total Capacity
24W
50W
125W
16 -100W
36 - 450W
100 - 450W
TM
6ELM2P
IND6, IND12, IND24
If the facility is not utilizing unit equipment for its emergency lighting, the exit discharge
remote(s) can be powered by special exit signs that are placed above any door leading to the
exit discharge. The exit/unit combination, LHQM, provides 6 to 21.6 watts of remote capacity
depending on the unit and option(s) selected (see chart below). The ELA LEHO is a canopy
accessory that provides 11 watts of remote capacity after it has been field-installed on a
Signature® LED emergency exit sign.
Application
Commercial / Light Industrial
Commercial / Light Industrial
Commercial / Light Industrial
Commercial / Light Industrial
ELA LEHO
Unit
LHQM with HO
LHQM with R0
LHQM with HO & R0
ELA LEHO
Volts
6
6
6
6
Remote
Capacity (Watts)
10.8
10.8
21.6
11
LHQM
Page 3
Codes
Life Safety Code (NFPA 101)
Section 3.3.136 Means of Egress:
A continuous and unobstructed way of travel from any point in a building or structure to a
public way consisting of three separate and distinct parts: (1) the exit access, (2) the exit, and (3)
the exit discharge.
Section 3.3.136.1 Accessible Means of Egress
Section 7.9 Emergency Lighting:
7.9.1.2 “. . .exit discharge shall include only designated stairs, ramps, aisles, walkways, and
escalators leading to a public way.”
Section 7.9.2 Performance of System:
7.9.2.1 “Emergency illumination shall be provided for not less than 1-½ hours in the event of
failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial
illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less
than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels
shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any
point, not less than 0.06 ft-candle (6.5 lux) at the end of the 1-½ hours. A maximum-to-minimum
illumination uniformity ratio of 40 to 1 shall not be exceeded.”
Since exit discharge is one of the three components defined as the "means of egress" per 3.3.121
of the Life Safety Code and since 7.9.1.1 also includes exit discharge, many authorities having
jurisdiction have concluded that the lighting levels of 7.9.2.1 apply in full. Note: Variations may
exist depending upon the interpretation of codes in your area.
Reprinted with permission from NFPA 101® Life Safety Code®, 2003 Edition. National Fire Protection Association, Quincy,
Massachusetts 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which
is represented only by the standard in its entirety.
Lithonia Lighting
© 2002 Acuity Lighting Group, Inc., 09/03
Form No. 680.193
680.193.p65
Acuity Lighting Group, Inc.
Emergency Lighting Systems
One Lithonia Way, Decatur, GA 30035
Phone 800 334-8694, Fax 770 981-8141
In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Small, attractive, round, outdoor remote core light. Ideal for use outside doorways to meet exit discharge requirements of the Life Safety Code. To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system
providing light for the path of egress.
Unit Accessories
ELA CL
CONSTRUCTION
Copper-free cast-aluminum face plate with stainless steel hardware. Standard
with satin bronze finish. Weather-tight cable connector with 5', 12-gauge, 2wire, low-voltage cable.
Core Light
INSTALLATION
Installs with counter sunk 3/16" diameter screws (not provided).
LAMP
Variety of MR16 lamp wattages and voltages available.
ORDERING INFORMATION
ELA
Family
ELA
Emergency
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA CL H0506
CL
Housing color
(blank) Bronze
Lamp type
Fixture
CL Round outdoor
step light
H0506
H1006
H2006
H1012
H2012
5W/6V MR16 lamp
10W/6V MR16 lamp
20W/6V MR16 lamp
10W/12V MR16 lamp
20W/12V MR16 lamp
Sheet #: ELA CL
RAUE-130
ELA CL Core Light
DIMENSIONS
All dimensions are in inches (centimeters).
4-1/2"
(11.4)
5" dia
(12.7)
1-3/8"
(3.4)
Cast aluminum
face 1
3-1/2" O.C.
(8.8)
68" angle = A
90" angle = B
Weather - light cable
connector with 5'0",
12 Ga., 2 wire low
voltage, cable.
Two countersunk,
3/16" dia. holes
(hardware by others)
Rectilinear lens provides
wide lateral distribution
with prisms in vertical
position and long narrow
distribution in horizontal
Provide 2-1/2" dia.
Hole for slip fit.
Lithonia Lighting
Sheet #: ELA CL
© 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. Matches
Indura® family appearance.
Unit Accessories
ELA IND
CONSTRUCTION
Fully adjustable lamp heads meet all aiming requirements. Lamp head and
mounting plate constructed of heavyweight polycarbonate. Removable bezel allows tool-less lamp replacement and easy maintenance.
INSTALLATION
Remote Fixture
Universal mounting base for use with single- or twin-head applications.
Base may be installed horizontally for single lamps or vertically for twin-head
applications. Attaches to single gang J-box with a 3-9/32" hole spacing or
comparable adaptations.
LAMPS
Krypton, incandescent and halogen composite lamps available in 6, 12 and
24 volts; 6 to 20 watts. Unique, field-adjustable beam pattern for composite
lamps by rotating bezel. Incandescent and halogen sealed-beam lamps
available on 6 and 12 volts; 6 to 50 watts.
Refer to specification sheet UE-615, UE-625, UE-626, UE-627 or the Indura
Application Guide (form no. 680.185) for spacing and performance comparisons between lamps.
DIMENSIONS
Mounting base: 5-1/8"W (128mm) x 4-11/16"H (120mm) x 4-15/16"D (125mm)
Single: 5-1/8"W (128mm) x 5-7/8"H (149mm) x 5-7/16"D (138mm)
Twin: 7-1/8"W (181mm) x 5-1/8"W (128mm) x 5-7/16"D (138mm)
LISTING
Listed in accordance with UL 1598.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA K0906
ELA
Remote head
ELA
IND
Color
(blank) Gray / blue housing
W Ivory white
Number of heads
(blank) Single
T Twin
Family
IND Indura
Lamp type
6 Volts:
PAR36 Composite
K0906 9W/6V krypton
H1206 12W/6V halogen
H2006 20W/6V halogen
12 Volts:
PAR36 Composite
K0912 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
PAR36 Sealed-beam
H3512S 35W/12V halogen
H5012S 50W/12V halogen
24 Volts:
PAR36 Composite
N1824 18W/24V incandescent
H2024 20W/24V halogen
PAR36 Sealed-beam
N5024S 50W/24V incandescent
Emergency
Sheet #: ELA-IND-NX
RAUE-180
Catalog Number
FEATURES & SPECIFICATIONS
Notes
INTENDED USE
Type
To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. Ideal for damp
and wet location areas requiring remote lighting.
Unit Accessories
CONSTRUCTION
ELA NX
Single or twin heads available. Fully adjustable lamp heads meet all aiming
requirements. Constructed of fiberglass-reinforced Lexan. Fully gasketed
mounting plate. Removable bezel and sealed, phosphor-bronze slip-on lamp
terminals.
Sealed Remote Fixture
INSTALLATION
Universal mounting plate for use with single or twin-head applications. Attaches to single gang J-box with a 3-9/32" hole spacing or comparable adaptations.
LAMP
Glass sealed-beam PAR36 lamp(s).
DIMENSIONS
Mounting base: 3-1/8"W (79mm) x 5"H (127mm)
Single: 7-3/4"H (197mm) x 4-3/4"W (121mm) x 4-9/16"D (116mm)
Twin: 6-5/8" (168mm) x 13" (330mm) x 3-11/16" (93mm)
LISTING
Listed for wet location in accordance with UL1598.
ORDERING INFORMATION
Example:
ELA
NX
Family
ELA
ELA NX H1212
Housing color
(blank) Gray
W White
B Black
Number of heads
(blank) Single
T Twin
Fixture
NX Sealed and
gasketed PAR36
Lamp type (PAR36 sealed-beam)
Incandescent
N0806 8W/6V
N1206
12W/6V
N1212 12W/12V
N1812 18W/12V
N2512
25W/12V
N3512
35W/12V
Halogen
H0606
6W/6V
H0806
H1206
H0812
8W/6V
12W/6V
8W/12V
H1212
12W/12V
H3512
H5012
35W/12V
50W/12V
Lithonia Lighting
Sheet #: ELA-IND-NX
© 2004 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
Support bracket for pendant mounting the Indura® small housing. Not available for large housing units.
Unit Accessories
FEATURES
16 ga. galvanized sheet steel.
3.8" x 4" x 1.45"
Includes one pendant mount bracket and two 1/2" slotted hex head screws.
ELA IND PM
Conduit and canopy are not provided.
Pendant Mount Kit
ORDERING INFORMATION
Catalog
Number
ELA IND PM
Description
Pendant mount kit for Indura small housing: IND618, IND654,
IND1236, IND1254, IND6100.
FEATURES & SPECIFICATIONS
Battery support brackets for use when ceiling mounting the Indura small
housing unit. Not available for large housing units.
FEATURES
Unit Accessories
ELA IND CM
20 ga. galvanized sheet steel
Includes one ceiling-mount bracket and one Phillips head screw.
Ceiling Mount Kit
ORDERING INFORMATION
UL listed products
Catalog
Number
ELA IND CM1
ELA IND CM2
ELA IND CM3
ELA INDX CMZ
Emergency
Description
Ceiling mount kit for IND618
Ceiling mount kit for IND654, IND1236, IND1254, INDX654,
INDX1236 and INDX1254
Ceiling mount kit for IND6100
Ceiling mount kit for INDX654, INDX1236, INDX1254
Sheet #: ELA-IND-PM-CM-RHB
RAUE-220
Catalog Number
FEATURES & SPECIFICATIONS
Bracket for surface mounted single-gang j-boxes with 3-9/32" hole spacings for Indura remote heads.
Notes
Type
FEATURES
Seals opening between surface mount box and Indura mounting plate.
Dimensions fit footprint of remote Indura head mounting plate.
Unit Accessories
ELA IND RHB
Indura® Remote Head Bracket
ORDERING INFORMATION
Catalog
Number
ELA IND RHB
Description
Remote head bracket to use with surface-mounted jboxes.
FEATURES & SPECIFICATIONS
Prepack provides template and hardware to field install third head on Indura
unit equipment.
FEATURES
Includes template and instructions to help with the drilling of holes for the
third lamp on the small or large Indura housing.
Includes necessary hardware to field install third head.
Tools needed: 9/64" (.140") dull bit; 1/2" (.500") dull bit Phillips screwdriver.
Unit Accessories
ELA IND R3
Indura® Third Head Mounting Kit
ORDERING INFORMATION
Catalog
Number
Description
ELA IND R3
Prepack kit to field install third head on Indura unit.
Lithonia Lighting
Sheet #: ELA-IND-PM-CM-RHB-R3
© 2000 Acuity Lighting Group, Inc., Rev. 8/06
Emergency Lighting Systems
One Lithonia Way, Lithonia, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Attractive, unique emergency downlight remote utilizing MR16 lamps. Innovative and advanced, the MR16 halogen luminaire provides excellent lighting control. Available in a range of trim styles. Frame-in module and trim supplied. To be
powered by 6- or 12-volt battery equipment as part of an emergency lighting
system providing light for the path of egress.
Unit Accessories
ELA LV3
CONSTRUCTION
Tempered glass safety lens standard. Drawn, one-piece seamless 5-1/4" aluminum housing. Lightweight, rust resistant.
Factory-installed, expandable, captive bar hangers with double-barbed, 3/4" recessed nailers. Bar hangers adapt to T-bar with no additional accessories.
Crimp locking on J-box side plus locking clip on rail side allow off-center mounting anywhere between 24" rigid joists or T-bar. Length of 25-1/4" maximum, 13-1/
4" minimum or cut to fit a minimum space of 7-1/2".
3" MR16 Downlight Series
Galvanized steel junction box with semi-captive snap-on covers and ground
wire. Built-in Romex clamps secure Romex cable inside J-box. Easy to remove
1/2" and 3/4" pryouts provided for straight-through conduit runs. Capacity: 4 (2 in,
2 out) No. 12 AWG conductors, rated for 90oC. Approved for all wiring types.
Adjustment slots in can accommodate ceiling thicknesses up to 2". Precisionwound stepdown transformer with class H insulation. For dimming control, use
only dimmers specifically designed for use with transformers. Two-pin porcelain socket.
16
15
TRIM
Three trim styles available: Baffle Reflector, Adjustable Specular Open and
Baffle Eyeball.
INSTALLATION
Retaining clips hold finishing trim secure and snug to ceiling.
Baffled Reflector
ORDERING INFORMATION
ELA
LV3
Family
Series
ELA
LV3
Baffled Eyeball
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA LV3 SB H1006
Trim
SB
OC
EB
Emergency
Open Clear Specular
Baffled reflector white
Adjustable spectular
open-clear
Baffled eyeball-white
Lamp type
H0506
H1006
H2006
H1012
H2012
H3512
H5012
5W/6V MR16 lamp
10W/6V MR16 lamp
20W/6V MR16 lamp
10W/12V MR16 lamp
20W/12V MR16 lamp
35W/12V MR16 lamp
50W/12V MR16 lamp
Sheet #: ELA LV3
RAUE - 160
ELA LV3 3" MR16 Downlight Series
DIMENSIONS
All dimensions are inches (centimeters).
5"
(12.7)
Baffled Reflector
Adjustable Open
Clear Specular
3-5/8"
(9.2)
5"
(12.7)
3-5/8"
(9.2)
5"
(12.7)
Baffled Eyeball
1-3/4"
(4.4)
3"
(7.6)
5"
(12.7)
4"
(10.2)
11-3/4"
(29.8)
13-1/2"
(34.3)
6"
(15.2)
4"
(10.2)
Lithonia Lighting
Sheet #: ELA LV3
© 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog
Notes
Type
SPECIFICATIONS
INTENDED USE
To be powered by 6- or 12-volt battery equipment as part of an emergency
lighting system providing light for the path of egress. MR24 fixture matches the
appearance of the Quantum® family units.
CONSTRUCTION
Unit Accessories
ELA MR24
Single or twin heads available. Fully adjustable lamp heads to meet all aiming
requirements. Strong, compact and corrosion-resistant with a UL94V-O flame
rating. Constructed of UV-stabilized thermoplastic that resists discoloration by
natural or artificial sunlight. Lamp housing snaps off for easy lamp replacement. US Patent No. D484,272.
INSTALLATION
Remote Fixture
Adjustable lamp head
Universal mounting base for use with single- or twin-head applications. Standard mounting: 6.78"W x 4.58"H. Mounts to a single-gang switch box.
LAMP
Complete range of lamp wattages and voltages available.
DIMENSIONS
Single and twin: 8"W x 4.58"H.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA MR24
ELA
Family
ELA
MR24
Housing color
(blank) White
B Black
Emergency
Number of heads
(blank) Single
T Twin
Fixture
Lamp type
MR24 Multi-faceted reflector
and adjustable lamp head
K0606
6W/6V krypton lamps
K0906
9W/6V krypton lamps
K0912
9W/12V krypton lamps
H1206
H1212
H2006
H2012
12W/6V halogen lamps
12W/12V halogen lamps
20W/6V halogen lamps
20W/12V halogen lamps
Sheet #: ELA-MR24
RAUE-105
ELA MR24 Quantum® Thermoplastic Remote Fixture
Lithonia Lighting
Sheet #: ELA-MR24
© 2002 Acuity Brands Lighting, Inc., Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
INTENDED USE
Unit Accessories
To be powered by 6, 12 or 24 volt battery equipment or 120 volt power source
as part of an emergency lighting system providing light for the path of egress.
MT fixture matches industrial unit.
ELA MT
CONSTRUCTION
Single or twin heads available. Fully adjustable lamp heads meet all aiming
requirements. Brushed aluminum lamp housing and steel mounting plate.
Removable steel ring provides easy lamp replacement.
Remote Fixture
INSTALLATION
Single mounting plate: 2-3/4"W x 4-1/2"H, mounts to single-gang switch box.
Twin mounting plate: 8-1/4"W x 4-1/2"H, mounts to four-gang j-box.
LAMP
Glass sealed-beam PAR36 lamp(s).
DIMENSIONS
Single: 4-5/8"W x 4-5/8"H. Twin: 11"W x 4-5/8"H.
LISTING
Listed in accordance with UL 1598 and CSA C22.2 No. 250.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA MT N0806
MT
ELA
Family
Housing color
ELA
(blank) Brushed
aluminum
Number of
heads
(blank) Single
T Twin
Lamp type (PAR36 sealed-beam)
Fixture
MT Metal PAR36
sealed-beam
SPECIFICATIONS
N0806
N1206
N1806
N1212
N1812
N2512
N15120
8W/6V incandescent
12W/6V incandescent
18W/6V incandescent
12W/12V incandescent
18W/12V incandescent
25W/12V incandescent
15W/120V incandescent,
composite
N30120 30W/120V incandescent,
composite
N50120 50W/120V incandescent,
composite
H0606
H0806
H1206
H0812
H1212
H3512
H5012
6W/6V halogen
8W/6V halogen
12W/6V halogen
8W/12V halogen
12W/12V halogen
37.5W/12V halogen
50W/12V halogen
Unit Accessories
INTENDED USE
Ideal for remote applications where a weather proof fixture is necessary.
CONSTRUCTION
Aluminum housing and swivel. Clear, heat-resistant glass globe. 35W PAR46
sealed-beam incandescent lamp.
ELA WP
Waterproof Fixture
DIMENSIONS
Single: 6-3/8"W x 8-1/2"H.
ORDERING INFORMATION
Example: ELA WP
Catalog
Number
Volts
Watts
Lamp
No.
ELA WP
12
35
4413
Emergency
Sheet#:ELA-MT-WP-Z
RAUE-190
Catalog Number
SPECIFICATIONS
INTENDED USE
To be powered by 6 or 12 volt battery equipment as part of an emergency
lighting system providing light for the path of egress in Class 1, Division II
environment.
CONSTRUCTION
Single or twin heads available.
Fully adjustable lamp heads meet all aiming requirements.
Lamp head constructed of lightweight, gray, thermoplastic and fully gasketed.
Removable bezel and slip-on lamp terminals simplify maintenance and lamp
replacement.
Strong, compact and corrosion-resistant with a UL94V-0 flame rating.
INSTALLATION
Mounting plate: 5"H x 3-1/8"W. Mounts to single-gang switch box.
LAMP
Glass sealed-beam PAR36 lamp(s).
DIMENSIONS
Notes
Type
Unit Accessories
ELA Z
Class I, Div. 2
Remote Fixture
Single: 5.1" W x 6.25" H.
ORDERING INFORMATION
ELA
Z
Family
Fixture
ELA
Z
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA Z N0806
Number of heads
Class 1, Div II remote head
(blank)
T
Single
Twin
Lamp type (PAR36 sealed-beam)
N0606
N0806
N1806
N1212
N1812
N2512
H0806
H1206
H0812
H1212
6W/6V incandescent
8W/6V incandescent
18W/6V incandescent
12W/12V incandescent
18W/12V incandescent
25W/12V incandescent
8W/6V halogen
12W/6V halogen
8W/12V halogen
12W/12V halogen
Lithonia Lighting
Sheet#:ELA-MT-WP-Z
© 2000 Acuity Brands Lighting Inc., Rev. 2/18/08
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
Unit Accessories
INTENDED USE
Small, attractive remote head utilizing MR11 lamps. Ideal for use outside of
doorways to meet exit discharge requirement of the Life Safety Code. To be
powered by 6- or 12-volt battery equipment as part of an emergency lighting
system providing light for the path of egress.
ELA OMC
CONSTRUCTION
Die-cast aluminum body with cast bronze knuckle. Cylinder standard with black
finish. Tempered glass lens.
INSTALLATION
1/2" NPT adjustable knuckle. Single mounting plate - round die-cast 4-0 box cover.
OUTDOOR MINI CYLINDER
Twin mounting plate dimensions (rectangle): 4-1/2"L x 2-7/8"W.
LAMP
Variety of MR11 lamp wattages and voltages available.
LISTING
UL Listed. IP rating: 65. UL Listed for wet locations.
DIMENSIONS
All dimensions are inches (centimeters).
Dimensions shown are for single mounting plates.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA OMC H0506
ELA
Family
ELA
Emergency
OMC
Housing color
(blank) Black
DNA Natural aluminim
DDB Dark bronze
Fixture
(blank) Single
T Twin
Fixture
OMC Outdoor mini-cylinder
Lamp type
H0506
H1006
H2006
H1012
H2012
5W/6V MR11 lamp
10W/6V MR11 lamp
20W/6V MR11 lamp
10W/12V MR11 lamp
20W/12V MR11 lamp
Sheet #: ELA-OMC-ELA-AFNR
RAUE-140
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
®
INTENDED USE
For applications requiring low-profile, attractive emergency lighting.
To be powered by 6V battery equipment as part of an emergency lighting system, providing light for the path of egress. Ideal for damp and wet location areas
requiring remote lighting.
CONSTRUCTION
Compact, low-profile, architectural design with die-cast aluminum housing that
has a contemporary brushed nickel-plated finish. Other available finishes are
texturized polyester powder coat paint in white, black and dark bronze. All finishes can be painted in the field to match the wall color of choice.
U.S. Patent No. D468,046.
Two 6-watt, 6-volt, wedge-base xenon lamps offer 55 percent more light output
than standard incandescent lamps. Meets requirements for NEC 700.16.
Patent-pending reflector/refractor design features superior vac-metalized, diecasted reflectors; and multi-faceted, highly transmissive refractor that significantly improve photometrics.
Unit Accessory
ELA AFNR
REMOTE FIXTURE
Universal J-box mounting pattern.
Rigid conduit entry provision on top of the unit.
LISTING
UL Listed for wet locations in accordance with UL 924. Cold weather listed -18°C
to 50°C.
ORDERING INFORMATION
ELA
AFNR
Family
Fixture
ELA
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA AFNR DB
Finish
AFNR Remote Affinity
fixture
W White
B Black
BN Brushed nickel
DB Dark bronze
NOTE:
Refer to AFN specification sheet for photometric and
dimensional data.
Lithonia Lighting
Sheet #: ELA-OMC-ELA-AFNR
©2007 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Systems Group
One Lithonia Way, Conyers, Ga 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Small, attractive rectangular outdoor remote step light. Ideal for use outside
doorways to meet exit discharge requirements of the Life Safety Code. To be
powered by 6- or 12-volt battery equipment as part of an emergency lighting
system providing light for the path of egress.
CONSTRUCTION
Unit Accessories
ELA OSL
Outdoor Step Light
Cast bronze fixture with stainless steel fasteners. Diffused tempered glass
lens. Completely weatherproof with neoprene gasket.
INSTALLATION
One 3/4"NPT tapper entrance hub at each end standard.
LAMP
Halogen bi-pin lamp - not included
LISTING
UL Listed. UL Listed for wet locations.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA OSL
ELA
Family
ELA
Emergency
OSL
Housing color
(blank) Bronze
Fixture
OSL
Outdoor step light
Sheet #: ELA OSL
RAUE - 150
ELA OSL Outdoor Step Light
DIMENSIONS
All dimensions are in inches (centimeters).
10-1/2"
(26.7)
5-3/8"
(13.7)
3-1/4"
(8.3)
1-5/8"
(4.1)
3-1/4"
(8.3)
3/4"
(1.9)
Lithonia Lighting
Sheet #: ELA OSL
© 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
CONSTRUCTION
Aluminum with matte white finish on exposed surfaces.
Unit Accessories
ELA RG
Mounts recessed into 5-3/4" diameter opening in wall or ceiling.
Gimbal suspension provides aiming through 70o tilt and 359o rotation.
4-inch standard box and "T" retainer clips included.
MOUNTING
Mounts recessed into 5-3/4" diameter opening in wall or ceiling.
LAMP
PAR36 sealed-beam lamp included.
Recessed Gimbal
Front-relamping: remove two screws in trim to access lamp housing.
DIMENSIONS
Single: 8-1/4"W x 5-1/4"D.
ORDERING INFORMATION
RG
ELA
Fixture
Family
ELA
Lead times will vary depending on options selcted. Consult with your sales representative.
Example: ELA RG N0806
RG
Recessed gimbal
Lamp type
N0806 8W/6V incandescent
PAR36 sealed-beam
N1212 12W/12V incandescent
PAR36 sealed-beam
N1812 18W/12V incandescent
PAR36 sealed-beam
N2512 25W/12V incandescent
PAR36 sealed-beam
H0806 8W/6V halogen PAR36
sealed-beam
H0812 8W/12V halogen PAR36
sealed-beam
H1212 12W/12V halogen PAR36
sealed-beam
SPECIFICATIONS
Unit Accessories
CONSTRUCTION
ELA SG
Aluminum with matte white finish on exposed surfaces.
Gimbal suspension provides aiming through 70o tilt and 359o rotation.
4-inch standard box included.
MOUNTING
Mounts on wall or ceiling.
Surface Gimbal
LAMP
PAR36 sealed-beam lamp included.
Front relamping: remove two screws in trim to access lamp housing.
DIMENSIONS
Single: 7-7/8" W x 4" D.
ORDERING INFORMATION
ELA
SG
Fixture
Family
ELA
Emergency
Lead times will vary depending on options selcted. Consult with your sales representative.
Example: ELA SG N0806
SG
Surface gimbal
Lamp type
N0806 8W/6V incandescent
PAR36 sealed-beam
N1212 12W/12V incandescent
PAR36 sealed-beam
N1812 18W/12V incandescent
PAR36 sealed-beam
N2512 25W/12V incandescent
PAR36 sealed-beam
H0806 8W/6V halogen PAR36
sealed-beam
H0812 8W/12V halogen PAR36
sealed-beam
H1212 12W/12V halogen PAR36
sealed-beam
Sheet#: ELA-RG-SG-RR
RAUE - 120
Catalog Number
SPECIFICATIONS
CONSTRUCTION
Notes
Type
Housing constructed of matte black steel with removable white front bezel.
Dropped frosted glass lens.
Double-contact bayonet base socket. Accepts S8 or S11 lamp, 25 watts maximum (lamp not included).
MOUNTING
Mounts recessed into opening 6-1/2" x 3-1/4", 2-3/4" deep in wall or ceiling.
LAMP
S8 or S11 DC bayonet base lamp up to 25W (not included).
DIMENSIONS
Single: 8-3/16"W x 4-1/2"H.
Unit Accessories
ELA RR
Recessed Rectangle
ORDERING INFORMATION
ELA
RR
Family
Fixture
ELA
RR
Lead times will vary depending on options selcted. Consult with your sales representative.
Example: ELA RR
Recessed rectangle
Lithonia Lighting
Sheet #: ELA-RG-SG-RR
© 1997 Acuity Brands Lighting, Inc., Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
Provides remote testing capability for all Lithonia unit equipment and exit signs.
CONSTRUCTION
Remote test switch plate includes white rocker-type test switch.
White plate matches most ceiling tiles.
Remote test switch plate installs onto a standard single-gang switch box
with screws (provided).
Mounts in ceiling or wall near emergency lighting unit.
OPERATION
Unit Accessories
ELA RTLP
REMOTE TEST SWITCH
Compatible with all Lithonia emergency lighting units and exits. Not compatible with emergency downlights and Power Sentry inverters.
Provides the ability to test the emergency operation of the unit from a remote location.
Recommended mounting no more than 25' from lighting unit.
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELARTLP
ELARTLP
Family
ELARTLP
Remote test switch
for unit device
Unit Accessories
SPECIFICATIONS
®
For mounting ELM4, ELM10, ELU Series or Titan Series unit equipment on
wall or pole.
CONSTRUCTION
Heavy-gauge steel construction with instrument tan finish.
ELA MS
MOUNTING
Shelf mounts onto wall or pole with screws (not provided).
MOUNTING SHELF
Unit attaches directly onto shelf with screws (not provided).
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA MS4/8
Family
ELA MS2
ELA MS4/8
ELA MST
ELA MSTS
20-gauge
16-gauge
18-gauge
18-gauge
steel
steel
steel
steel
shelf for ELU2, ELU2P*
shelf for ELU4, ELU8, ELM4, ELM10*
shelf for Titan ELT180, ELT250, ELT275
shelf for Titan ELT16, ELT24, ELT24C, ELT36, ELT36C, ELT50
*To order white, add W to the catalog number. Example: ELA W MS4/8
Emergency
Sheet#: ELA-RTLP-MS-VS2-WG
RAUE - 200
Catalog Number
SPECIFICATIONS
To provide protection from vandalism for the ELM and ELM2 (ELA VS), and
large QUANTUM® products (ELA VS2).
Notes
Type
CONSTRUCTION
Unit Accessories
1/8" thick (ELA VS2) or 3/16" thick (ELA VS), high-impact, transparent polycarbonate.
Fits all QUANTUM ELM and ELM2 (ELA VS), and larger QUANTUM units
(ELA VS2).
Contemporary rounded-corner design.
10" H x 22" W x 9-3/4" D (ELA VS2); 8-1/2" H x 15" W x 4-3/4" D (ELA VS).
ELA RTLP remote test switch recommended; mounts up to 25' from unit.
MOUNTING
Twelve 3/6" diameter pre-drilled mounting holes.
ELA VS2
ELA VS
ELA VS2
Vandal-resistant hardware not provided.
VANDAL-RESISTANT SHIELD
ELA VS
ORDERING INFORMATION
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA VS
Family
ELA VS
ELA VS2
Vandal shield for ELM and ELM2 unit equipment
Vandal shield for large Quantum products (ELM618, ELM627,
ELM654, ELM1254 and ELM1272)1
NOTES:
1 ELA VS2 can be used with discontinued 6ELM2P, ELM4 and ELM10.
SPECIFICATIONS
Unit Accessories
Provides protection from vandalism for units and remote heads.
ELA WG
CONSTRUCTION
1/4" steel rod construction on front and sides with zinc plate finish — ELA
WG4/8, ELA WGRH, ELA WGLT, ELA WG2.
3/16" steel rod construction on front sides, top and bottom with powdercoated metallic gray finish — ELA WG2M, ELA WGHQM, ELA WGST.
WIREGUARD
MOUNTING
Four 7/16" diameter mounting holes — ELA WG4/8, ELA WGRH, ELA WGLT,
ELA WG2.
Four 3/8" diameter mounting holes — ELA WG2M, ELA WGHQM, ELA WGST.
COMPATIBILITY AND ORDERING INFORMATION
U.S. Units
ELA WGHQM
ELA WGLG
ELA WGLT
ELA WGRH
ELA WGST
ELA WG2
ELA WG2M
ELA WG4/8
■
IND (150-450 Watts) IND
100W PREM & ULT
ELM, ELT 16, 24, 36, 50,
ELSQ
LHQM
ELM2, ELM4, ELM10,
ELU8, 6ELM2, 6ELM2P
IND (16-100 Watts) Not IND
100W PREM & ULT
ELT 50 (w/option),
125, 180, 250, 275
Twin remote heads
Single remote heads
Catalog
Number
ELT 502 (w/options),
1252, 180 2, 2502, 2752, INDX
UL Listed Products
■
■
■
■
■
■
■
■
Dimensions
28W x 15H x 8D
21W x 20H x 18D
2215/16W x 243/8H x 123/8D
1115/16W x 123/8H x 93/8D
15W x 15H x 6D
151/8W x 143/8H x 85/8D
201/4W x 15H x 10D
221/8W x 2215/16H x 10D
Lithonia Lighting
Sheet #: ELA-RTLP-MS-VS2-WG
©2000 Acuity Brands Lighting, Inc., Rev. 3/11/08
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
Hand-held InduraTM remote test transmitter used to initiate a 30second test for emergency lighting equipment that has been ordered
with the remote test receiver (RT option).
CONSTRUCTION
• Constructed of lightweight polycarbonate.
• 3" long, 1.75" wide, .775" deep.
OPERATION
• Pressing the remote transmitter button activates a 30-second test
from up to 35 feet away on each unit equipped with the remote
test receiver (RT option).
• Utilizes radio frequency technology, which minimizes interference
of obstructions that can sometimes be experienced with infrared
technology.
• Eliminates crucial time spent climbing ladders or riding lifts.
• Ideal for high mounting heights or applications where
accessibility to fixture is limited, making performance of a monthly
30-second test required by the Life Safety Code labor intensive.
• A minimum of one per job location is required for units ordered
with the remote test receiver (RT option)
• FCC compliant.
BATTERY
Unit Accessories
ELA RTT
Remote Test Transmitter
• Utilizes A23 alkaline 12-volt battery with an expected 60 hours of
service at 70oF.
ORDERING INFORMATION
Catalog
Number
Description
ELA RTT
Remote test transmitter
Emergency
Sheet # ELA-RTT-BS
RAUE - 210
Catalog Number
Notes
Type
SPECIFICATIONS
Mounting accessory banding strap to clamp InduraTM mounting
bracket to poles, columns or I-beams.
Unit Accessories
CONSTRUCTION
• Contains one 1/2" wide, 8-1/2' long, 100% stainless steel band.
• Includes three fasteners and one extender to make up a total of
three worm-drive clamps.
MOUNTING
• To determine lengths to cut, multiply diameter in inches by p
(3.1416), minus 4.5" for the adjustable fastener end, or determine
circumference by measurement, minus 4.5" for the adjustable fastener end.
ELA BS
Banding Strap
ORDERING INFORMATION
Catalog
Number
Description
ELA BS
Banding strap
1/2" wide
stainless steel
banding
1/2" wide
stainless steel
fastener and housing
assemblies
5/16" stainless
steel attached
hex-head screw
Lithonia Lighting
Acuity Lighting Group, Inc.
Emergency Lighting Systems
One Lithonia Way, Bldg. 3
Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Sheet #: ELA-RTT-BS
ela-rtt-bs.pmd
© 2000 Acuity Lighting Group, Rev. 12/05
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Attractively styled, unique emergency downlight remote. Available in a range of
trim styles and lamps. Frame-in module and trim supplied. To be powered by 6or 12-volt battery equipment as part of an emergency lighting system providing
light for the path of egress.
CONSTRUCTION
Sturdy steel housing with plaster frame for plaster or tile construction. 27" expandable bar hangers with nailer tabs. Locking screw for off-center mounting
between joist or T-bars. Aluminum snap-cap houses quick connector for easy
connection to trim assembly.
Unit Accessories
ELA SB,
ELA OC, ELA EB
TRIM
Three trim styles available: Clear Alzak* Open Cone, Black Stepped Baffle and
Black Baffle Eyeball. Internal yoke assembly permits 358o horizontal adjustment
and 35o vertical tilt. One-piece reflector/trim eliminates light leaks. Sealed-beam
lamp available in 6- or 12-volt incandescent or halogen.
6" Downlight Series
* Alzak is a registered trademark of Alcoa.
Stepped Baffle
ORDERING INFORMATION
Clear Alzak
Baffled Eyeball
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA OC N0806
ELA
Trim style
Family
ELA
OC
SB
EB
®
Clear Alzak open cone
Black stepped baffle
Black baffleeyeball
Lamp type
N0806
N1212
H0806
H1212
Emergency
Incandescent 8W/6V PAR36
lamp
Incandescent 12W/12V PAR36
lamp
Halogen 8W/6V PAR36 lamp
Halogen 12W/12V PAR36 lamp
Sheet #: ELA SB OC EB
RAUE - 170
ELA SB, ELA OC, ELA EB 6" Downlight Series
DIMENSIONS
All dimensions are in inches (centimeters).
Stepped Baffle
9-3/8"
(23.8)
Baffled Eyeball
Clear Alzak
5"
(12.7)
9-3/8"
(23.8)
6"
(15.2)
6"
(15.2)
7-5/8"
(19.3)
7-5/8"
(19.3)
4-1/4"
(10.7)
6-3/8"
(16.1)
7-5/8"
(19.3)
Lithonia Lighting
Sheet #: ELA SB OC EB
© 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part
of an emergency lighting system providing light for the path of egress. CDS
fixture matches the appearance of the Quantum® family units.
CONSTRUCTION — Single or twin heads available. Fully adjustable lamp
heads meet all aiming requirements. Strong, compact and corrosion-resistant
with a UL94V-0 flame rating. Constructed of engineering-grade thermoplastic.
Lamp housing snaps off for easy lamp replacement.
Unit Accessories
ELA CDS
INSTALLATION — Universal mounting plate for use with single or twin-head
applications. Standard mounting plate: 3-1/8" W x 5" H. Mounts to a singlegang switch box.
LAMP — Complete range of lamp wattages and voltages available.
DIMENSIONS — Single: 3-7/8"W x 4-1/4"H. Twin: 10-5/8"W x 4-1/4"H.
Remote Fixture
LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA CDS N0806
ELA
CDS
Family
Housing
color
ELA
(blank) Ivory
white
Number of
heads
Lamp type (composite lamps)
Fixture
CDS Compact
designer
square
(blank) Single
T Twin
N0606 6W/6V incandescent
N0806 8W/6V incandescent
N0912 9W/12V incandescent
N1212 12W/12V incandescent
Options
H0606 6W/6V halogen
H0806 8W/6V halogen
(blank) Standard
mounting
plate
H0812 8W/12V halogen
H1212 12W/12V halogen
Unit Accessories
FEATURES & SPECIFICATIONS
INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part
of an emergency lighting system providing light for the path of egress. SSB
fixture matches the appearance of the Quantum® family units.
CONSTRUCTION — Single or twin heads available. Fully adjustable lamp heads
meet all aiming requirements. Strong, compact and corrosion-resistant with a
UL94V-0 flame rating. Constructed of engineering-grade thermoplastic. Lamp
housing snaps off for easy lamp replacement.
INSTALLATION — Universal mounting plate for use with single or twin-head
applications. Mounting plate: 3-1/8" W x 5" D. Mounts to a single-gang
switch box.
ELA SSB
Remote Fixture
LAMP — Glass sealed-beam PAR36 lamp(s).
DIMENSIONS — Single: 4-3/4" W x 5" D. Twin: 10-1/2"W x 5"H.
LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250.
ORDERING INFORMATION
Lead times will vary depending on options selcted. Consult with your sales representative.
Example: ELA SSB N0806
SSB
ELA
Family
Housing color
ELA
(blank) Ivory white
TN Desert tan
Emergency
Number of heads
(blank) Single
T Twin
Fixture
SSB Square PAR36
sealed-beam
Lamp type (PAR36 sealed-beam)
N0806
N1206
N1212
N1812
N2512
N3512
8W/6V incandescent
12W/6V incandescent
12W/12V incandescent
18W/12V incandescent
25W/12V incandescent
35W/12V incandescent
H0606
H0806
H1206
H0812
H1212
H3512
Sheet #: UE-406
6W/6V halogen
8W/6V halogen
12W/6V halogen
8W/12V halogen
12W/12V halogen
35W/12V halogen
RAUE-100
Catalog Number
Notes
FEATURES & SPECIFICATIONS
Type
INTENDED USE — To be powered by 6 or 12 volt battery equipment as part of an
emergency lighting system providing light for the path of egress. This remote
fixture matches the ELU family appearance.
CONSTRUCTION — Single or twin heads available.
Unit Accessories
ELA
Fully adjustable lamp heads meet all aiming requirements.
Lamp head and mounting plate constructed of lightweight thermoplastic.
Removable bezel and slip-on lamp terminals simplify maintenance and lamp
replacement.
Strong, compact and corrosion-resistant with a UL94V-0 flame rating.
Remote Fixture
INSTALLATION — Universal mounting plate for use with single or twin-head
applications. Mounting plate: 5"H x 3-1/8"W. Mounts to single-gang switch box.
LAMP — Glass sealed-beam PAR36 lamp(s).
DIMENSIONS — Single: 4-3/4"W x 6-5/8"H. Twin: 13"W x 6-3/8"H.
LISTING — Listed in accordance with UL 1598 and CSA C22.2 No. 250.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELA N0806
ELA
Family
Housing color
ELA
(blank) Desert tan
W Ivory white
B Black
ITN Instrument
tan
Number of
heads
(blank) Single
Fixture
(blank) Standard PAR36
sealed-beam
T Twin
Lamp type (PAR36 sealed-beam)
N0806 8W/6V incandescent
N1206 12W/6V incandescent
N1212 12W/12V incandescent
N1812 18W/12V incandescent
N2512 25W/12V incandescent
H0606 6W/6V halogen
H0806 8W/6V halogen
H1206 12W/6V halogen
H0812 8W/12V halogen
H1212 12W/12V halogen
Unit Accessories
FEATURES & SPECIFICATIONS
INTENDED USE
To be powered by 6 or 12 volt battery equipment as part of an emergency
lighting system providing light for the path of egress. This remote fixture matches
applications using the ELSQ series.
CONSTRUCTION
Matte white polycarbonate frame and black thermoplastic housing are impactresistant and lightweight.
ELA SQ
Square Fixture
Durable and corrosion-resistant with a UL94V-0 flame rating.
Prismatic acrylic lens.
Tungsten halogen lamp.
Surface mounting.
DIMENSIONS
Single: 10-5/16"W x 10-5/16"L x 3-7/16"H.
ORDERING INFORMATION
Catalog
Number
ELA SQR6V
ELA SQR12V
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA SQR6V
Lamp
Volts
Watts
No.
6
12
10
12
787
783
NOTE:
For semi-recessed or fully recessed mounting, order additional kit ELA SRK or ELA FRK,
respectively.
Lithonia Lighting
Sheet #: UE-406
© 1997 Acuity Brands Lighting, Inc., Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
VOLTAGE DROP TABLES
The following information is provided to assist in planning layouts for emergency lighting systems.
The National Code limits voltage drop to a maximum of 5% of nominal. Thus, circuit runs must be of sufficient size to
maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting equipment.
The table below shows the length of wire run based on system voltage, wire gauge and total wattage on the run.
Formula: As per National Code standards,
VD = 2 x L x I x R
1000
where
L = length of run in feet
I = current
R = resistance of material at 75°C
VD = voltage drop
6-VOLT SYSTEM
Total
watts
12
Wire size
10
8
12-VOLT SYSTEM
6
4
Total
watts
12
length of wire run (feet)
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
73
63
55
44
37
34
31
27
24
22
21
18
18
15
13
11
9
9
7
6
4
4
3
3
2
2
2
1
1
116
100
87
70
58
54
50
44
39
35
33
29
28
23
20
17
15
14
12
9
7
6
5
4
3
3
3
2
2
185
159
139
111
93
86
79
70
62
56
53
46
44
37
32
28
23
22
19
15
11
9
9
6
6
5
4
4
3
294
252
221
176
147
136
126
110
98
88
84
74
71
59
50
44
37
35
29
24
18
14
12
10
9
8
7
6
4
Wire size
10
8
24-VOLT SYSTEM
6
4
Total
watts
12
length of wire run (feet)
467
401
350
280
234
216
200
175
156
140
134
117
112
93
80
70
58
56
47
37
28
22
19
16
14
12
11
9
7
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
293
251
220
176
146
135
125
110
98
88
84
73
70
59
50
44
37
35
29
23
18
14
12
10
9
8
7
6
4
465
399
349
279
233
215
199
174
155
140
133
116
112
93
80
70
58
56
47
37
28
22
19
16
14
12
11
9
7
742 1,176 1,869
636 1,008 1,602
556
882 1,402
445
706 1,121
371
588 935
342
543 863
318
504 801
278
441 701
247
392 623
222
353 561
212
336 534
185
294 467
178
282 449
148
235 374
127
202 320
111
176 280
93
147 234
89
141 224
74
118 187
59
94 150
44
71 112
36
56
90
30
47
75
25
40
64
22
35
56
20
31
50
18
28
45
15
24
37
11
18
28
10
Wire size
8
6
4
length of wire run (feet)
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
1,171
1,103
878
702
585
540
502
439
390
351
334
293
281
234
201
176
146
140
117
94
70
56
47
40
35
31
28
23
18
1,860
1,595
1,395
1,116
930
859
797
698
620
558
532
465
447
372
319
279
233
223
186
149
112
89
74
64
56
50
45
37
28
2,967
2,543
2,225
1,780
1,483
1,369
1,271
1,112
989
890
848
742
712
593
509
445
371
356
297
237
178
142
119
102
89
79
71
59
44
4,706
4,034
3,529
2,824
2,353
2,172
2,017
1,765
1,569
1,412
1,345
1,176
1,129
941
807
706
588
565
471
376
282
226
188
161
141
125
113
94
71
7,477
6,409
5,607
4,486
3,738
3,451
3,204
2,804
2,492
2,243
2,136
1,869
1,794
1,495
1,282
1,121
935
897
748
598
449
359
299
256
224
199
179
150
112
UE-610
VOLTAGE DROP TABLES continued
32-VOLT SYSTEM
Total
watts
12
48-VOLT SYSTEM
Wire size
10
8
6
4
Total
watts
12
length of wire run (feet)
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
2,081
1,784
1,561
1,249
1,041
961
892
780
694
624
595
520
500
416
357
312
260
250
208
167
125
100
83
71
62
56
50
42
31
3,307
2,835
2,481
1,984
1,654
1,527
1,417
1,240
1,102
992
945
827
794
661
567
496
413
397
331
265
198
159
132
113
99
88
79
66
50
5,274
4,521
3,956
3,164
2,637
2,434
2,260
1,978
1,758
1,582
1,507
1,319
1,266
1,055
904
791
659
633
527
422
316
253
211
181
158
141
127
105
79
8,366 13,292
7,171 11,393
6,275 9,969
5,020 7,975
4,183 6,646
3,861 6,135
3,585 5,696
3,137 4,984
2,789 4,431
2,510 3,988
2,390 3,798
2,092 3,323
2,008 3,190
1,673 2,658
1,434 2,279
1,255 1,994
1,046 1,661
1,004 1,595
837 1,329
669 1,063
502 798
402 638
335 532
287 456
251 399
223 354
201 319
167 266
125 199
120-VOLT SYSTEM
Wire size
10
8
6
Total
watts
Wire size
10
8
12
length of wire run (feet)
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
4,683
4,014
3,512
2,810
2,341
2,161
2,007
1,756
1,561
1,405
1,338
1,171
1,124
937
803
702
585
562
468
375
281
225
187
161
140
125
112
94
70
7,442
6,379
5,581
4,465
3,721
3,435
3,189
2,791
2,481
2,233
2,126
1,860
1,786
1,488
1,276
1,116
930
893
744
595
447
357
298
255
223
198
179
149
112
11,867
10,171
8,900
7,120
5,933
5,477
5,086
4,450
3,956
3,560
3,390
2,967
2,848
2,373
2,034
1,780
1,483
1,424
1,187
949
712
570
475
407
356
316
285
237
178
18,824
16,134
14,118
11,294
9,412
8,688
8,067
7,059
6,275
5,647
5,378
4,706
4,518
3,765
3,227
2,824
2,353
2,259
1,882
1,506
1,129
904
753
645
565
502
452
376
282
Example 1
Number of fixtures
A 12V system uses 8-gauge wire and will operate three
7W exit signs. Total watts on wire run is 21, length of run
from table is 212'.
Multiplier
Longer Wire Runs
If loads are uniformly spaced along circuit path (equal
watts, equal distances), the lengths in the table can be
increased by certain values.
Example 2
6
length of wire run (feet)
6
7
8
10
12
13
14
16
18
20
21
24
25
30
35
40
48
50
60
75
100
125
150
175
200
225
250
300
400
29,268
25,087
21,951
17,561
14,634
13,508
12,544
10,976
9,756
8,780
8,362
7,317
7,024
5,854
5,017
4,390
3,659
3,512
2,927
2,341
1,756
1,405
1,171
1,003
878
780
702
585
439
46,512
39,867
34,884
27,907
23,256
21,467
19,934
17,442
15,504
13,953
13,289
11,628
11,163
9,302
7,973
6,977
5,814
5,581
4,651
3,721
2,791
2,233
1,860
1,595
1,395
1,240
1,116
930
698
74,166 117,647
63,571 100,840
55,624 88,235
44,499 70,588
37,083 58,824
34,230 54,299
31,785 50,420
27,812 44,118
24,722 39,216
22,250 35,294
21,190 33,613
18,541 29,412
18,541 29,412
14,833 23,529
12,714 20,168
11,125 17,647
9,271 14,706
8,900 14,118
7,417 11,765
5,933
9,412
4,450
7,059
3,560
5,647
2,967
4,706
2,543
4,034
2,225
3,529
1,978
3,137
1,780
2,824
1,483
2,353
1,112
1,765
2
3
4
5
1.33
1.5
1.6
1.67
NOTE: To determine multiplier for six or more fixtures, use
the following formula.
Number of fixtures =
Multiplier =
n
2n
n+1
Exit signs from Example 1 will be uniformly spaced. Multiplier is 1.5 for three fixtures. Maximum permissible length
of wire run is 212' x 1.5, or 318'.
Lithonia Lighting
Sheet #: UE-610
© 1991 Lithonia Lighting, Rev. 6/97
Emergency Lighting Systems
One Lithonia Way, Bldg. 3; Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
CONSTRUCTION
Class II and III, Division 1
Corrosion-resistant, cast aluminum alloy with epoxy polyester finish.
Top-mount fixture with single wall remote has universal junction box with four
tapped holes for 3/4" rigid conduit (three close-up plug provided).
ELA ZCD
Twin wall remote has junction box with two tapped holes for 3/4" rigid conduit
(one close-up plug provided).
ELA ZCD H1212 UM fixture designed for direct mounting to ZX 1250N battery
unit (ZX1250N unit not included).
Utilizes 12W halogen lamps, 6V or 12V.
ELECTRONICS
Remote mount from area located outside the hazardous area via 6 VDC or 12
VDC battery unit.
Hazardous Location
Remote Lighting Fixtures
CODES
UL listed. Meets UL 924, 844, and 1203 illumination standards. UL listed for use
in Class II, Division 1, Groups, E, F & G and Class III areas.
WARRANTY
Three-year total customer satisfaction warranty. For details, see Product Selection Guide.
ORDERING INFORMATION
ELA
ZCD
Remote
Family
ELA
ZCD Hazardous
combustible
dust
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA ZCD H1212 WM
Heads
(blank)
T
Single
Twin1
Lamp type
Mounting
G4 bi-pin
H1206 12W/6V halogen
H1212 12W/12V halogen
WM Wall mount
TM Top mount
SM Side mount to
ZX1250N unit
Options
WGZCD
Wireguard
NOTES:
1 Only available with wall mount unit.
Emergency
Sheet#: ELA ZCD
SPUE - 340
ELA ZCD Hazardous Location Remote Lighting Fixtures
SPECIFICATIONS
DIMENSIONS
LAMPS
All dimensions are in inches (millimeters).
Shipping weight: 18 lbs. (8 kgs.)
Photometrics for 12 volt, 12 watt halogen head
ELA ZCD H1206
TM
ELA ZCD H1206 WM
ELA ZCD H1212 SM
ELA ZCD T H1206 WM
Lithonia Lighting
Sheet #: ELA ZCD
© 1999 Acuity Brands Lighting,Inc., 10/16/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Suitable for use in Class I, Div. 1, Groups C & D, Zones 0, 1 & 2, Groups
IIA, IIB + H2 & IIC; Class I, Div. 2, Groups C & D, Zone 2, Groups IIA, IIB +
H2 & IIC; Class II, Div. 1, Groups E, F & G; Class I, Div. 2, Groups F & G
and Class III hazardous location areas.
CONSTRUCTION
Copper-free cast-aluminum enclosure withstands pressure of explosions generated by internal arc without propagating them into the hazardous atmosphere. Enclosure has corrosion resistant, epoxy powder
coat finish.
Includes high-impact, heat-resistant globe with cast aluminum globe
guard.
Top and wall mount fixtures have a universal junction box with four
tapped holes for 3/4" rigid conduit (three close-up plugs provided.)
Pendant mount fixture has 3/4" top hub.
Choose from a variety of halogen lamps. Seven watt compact fluorescent lamps also available.
LISTING
UL listed. Meets UL 924 and 844 illumination standards.
WARRANTY
Three-year total customer satisfaction warranty. For details, see Product Selection Guide.
ORDERING INFORMATION
ELA
ZX
Family
Fixture
ELA
ZX
Explosion-proof
Emergency Lighting
ELA ZX
Hazardous Location Fixtures
for use with ZX Family
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELA ZX H0706 WM
Lamp type
Mounting
Emergency only, G4 bi-pin
H0706
7W/6V halogen
H1006
10W/6V halogen
H1206
12W/6V halogen
H1212
12W/12V halogen
WM Wall mount
PM Pendant
mount
TM Top mount
AC / emergency operation
CF0706 7W compact
fluorescent1
Accessories
Order as a separate item
ELA 3CH
ELA SEA
NOTES:
1 Only operates with ZX614N power pack in AC and emergency
modes. The maximum mounting distance from the ZX 614N is 8'.
See spec sheet UE-296 for more details.
Emergency
3-way explosion-proof 3/4" conduit hub
Swivel elbow arm for use with pendant mount
fixture to connect to ELA 3CH or ELA ZX unit
ELA EAK Exit accessory kit (red silk-screened letters on a
white background)
ELA SDR Straight dome reflector
Sheet#: ELA ZX
SPUE - 320
ELA ZX Hazardous Location Fixtures For Use With ZX Family
SAMPLE APPLICATION
DIMENSIONS
All dimensions are in inches (millimeters).
Shipping weight: 15 lbs. (7 kgs.)
Wall Mount
10.4"
(264)
14.3"
(362)
.8"
(20)
7.3"
The above sample application consists of:
(1) ZX614N - 14 watt power pack for exclusive use with compact fluorescent fixtures
(185)
Top Mount
(2) ELA SEA - Elbow arms
(2) ELA ZX H0706 P- 7 watt compact fluorescent lamp fixture
(1) ELA EAK - 7 watt compact fluorescent lamp fixture with exit accessory
Pendant Mount
14.3"
14.9"
(362)
(378)
7.3"
7.3"
(185)
(185)
ELA EAK (accessory)
17.8"
(452)
12"
(305)
Lithonia Lighting
Sheet #: ELA ZX
©1999 Acuity Brands Lighting, Inc., Rev. 10/16/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
CONSTRUCTION
Impact-resistant, fiberglass reinforced polyester housing. Gray with stainless steel hardware. View-through window allows easy monitoring of AC
indicator and optional voltmeter and ammeter.
Class I, Division 2 Emergency Lighting
Z
Housing suitable for use in NEMA 4, 4X, 12 and 13 areas; Class I, Division 2,
Groups A, B, C & D, Zone 2, Groups IIA, IIB + H2 & IIC and Class II, Division 2,
Groups F & G.
Lamp heads are Class I, Div. 2 rated polycarbonate sealed beam PAR36
tungsten or halogen lamps. Eight-watt tungsten lamps for 6-volt units and
12-watt tungsten lamps for 12-volt units are standard.
Optional shatter-resistant shield is designed for use in food service areas.
HAZARDOUS LOCATION UNITS
6 and 12 Volts, 25-125 Watts
BATTERY
Choice of sealed, maintenance-free lead-calcium battery or sealed, maintenance-free nickel-cadmium battery.
90-minute emergency operation at full light output.
ELECTRONICS
120/277 VAC dual-voltage input with surge-protected, solid-state charging
circuitry.
Low-voltage disconnect (LVD) feature disconnects battery prior to unacceptable deep discharge, but not before the required 90-minute emergency operation.
AC lockout prevents battery drain prior to energizing of utility power. Wiring and electrical connections can be completed without energizing
emergency circuit.
Brownout protection circuitry automatically switches unit into emergency
mode if utility voltage drops below 20% of nominal.
Battery charging circuitry utilizes constant-current charger for nickelcadmium battery units. Fully automatic, voltage-regulated charger used
for lead-calcium battery units. Battery recharge time after full discharge
less than required by UL 924 standard.
DIAGNOSTICS
Self-diagnostic option conducts automatic and manual tests, indicating
real time status of lamp, battery and charger via tri-color indicator lamps.
Automatic tests include systems analysis every 10 seconds, with actual
load tests performed for a three-minute duration every 30 days, and for a
30-minute duration every 180 days. Manual tests include a three-, 30- and
90-minute battery discharge and lamp illumination tests.
ORDERING INFORMATION
Family
6V, lead-calcium
Z625 25W 1
Z650 50W 1
Z6100 100W2,6
Z6125 125W 6
6V, nickel-cadmium
Z625N 25W1,3
Z650N 50W1,3
12V, lead-calcium
Z1225 25W1
Z1250 50W1,2
Z12120 120W 6
12V, nickel-cadmium
Z1225N 25W1,3
Z1250N 50W1,3
Z1275N 75W1,3
Z12100N 100W1,3
Z12125N 125W1,3
CODES
UL Listed. Meets UL 924 illumination standards. Select units additionally
listed to UL 844, 1203 and 1604. NFPA 70 and NFPA 101 NEC and OSHA illumination standards.
Units with nickel-cadmium batteries are also UL listed for Class II, Division
2, Groups F and G applications.
WARRANTY
Three-year total customer satisfaction warranty.
Lead times will vary depending on options selected. Consult with your sales representative.
Example: Z625 R1 N2506 SD
Voltage4
(blank) 120/277
NOTES:
1 In addition to UL 924, units are listed to 844, 1203 and 1604.
2 Includes temperature compensated charger.
3 Nickel-cadmium units are the only units listed for Class II, Div. 2, Groups F and G
applications.
4 Special voltages available. Consult factory.
5 Option configurations may impact UL listing. Consult factory for specifics.
6 Self-diagnostics is not available on Z6100, Z6125 and Z12120.
7 Only available with SD or SDA.
Emergency
TEST
No. of lamps
(blank)
R1
R0
Two
One
None
Lamp type
Options 5
PAR 36 sealed-beam
(blank) 8W/6V incand.
N1806 18W/6V incand.
N2506 25W/6V incand.
N3006 30W/6V incand.
H0806 8W/6V halogen
H1206 12W/6V halogen
(blank)
N1812
N2512
N3012
H0812
H1212
12W/12V incand.
18W/12V incand.
25W/12V incand.
30W/ 12V incand.
8W/12V halogen
12W/12V halogen
SD Self-diagnostics 6
SDA Self-diagnostics
with alarm
T D Time delay 120/2777
TD1 Time delay
120 VAC
TD2 Time delay
277 VAC
SRS Shatter-resistant
lamp head shield
Sheet #: Z
SPUE-360
Z
Class I, Division 2 Hazardous Location Emergency Lighting Units
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
All dimensions are in inches (millimeters).
Shipping weight:
Input power requirements
Z625 - 18 lbs. (8 kgs.)
Z650 - 18 lbs. (8 kgs.)
Z6100 - 27 lbs. (12 kgs.)
Z6125 - 29 lbs. (13 kgs.)
Z625N - 16 lbs. (7 kgs.)
Z650N - 18 lbs. (8 kgs.)
120 VAC - .58 amps max., 65 watts max.
277 VAC - .27 amps max., 68 watts max.
OPERATION
DC
Voltage
Standard
Lamp Head
Unit
Watts to 87½
of Rated Voltage
6
Z625
Z650
Z6100
Z6125
Z625N
Z650N
N0806
N0806
N0806
N0806
N0806
N0806
1 ½ hrs.
25
50
100
125
25
50
2hrs.
19
37.5
75
94
19
37.5
4hrs.
12
24
48
60
12
24
8hrs.
8.5
17
21.5
8.5
12
Z1225
Z1250
Z12120
Z1225N
Z1250N
Z1275N
Z12100N
Z12125N
N1212
N1212
N1212
N1212
N1212
N1212
N1212
N1212
25
50
120
25
50
75
100
125
19
37.5
90
19
37.5
56.5
75
94
12
24
58
12
24
28.5
48
60
8.5
20
8.5
15
17
21.5
25 Watt to 75 Watt Units
16"
(406)
12.4"
(315)
10"
(254)
100 Watt to 125 Watt Units
Voltage
Shelf
Life1
Expected
Life1
Maintenance
6
3 years
7-9 years
none3
Optimum
Temperature2
32°F - 100°F
(0°C - 37.8°C)
Voltage
Shelf
Life1
Expected
Life1
Maintenance
6 and 12
6 months
5-8 years
none3
18"
(457)
14.4"
(366)
Lead-Calcium
12"
(305)
Optimum
Temperature2
60°F - 90°F
(16°C - 32°C)
15.2"
(386)
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity for 90 minutes.
Higher and lower temperatures affect life and capacity. Consult factory for detailed
information.
3 Periodic system status test recommended.
o
N0806
6 Volts, 8 Watts, PAR 36
o
HORIZONTAL
HORIZONTAL
SPACING FACTOR
5
1.0
0.5
0.3
0
1.5
5
10
1.0
0.5
0.3
0.2
1.5
10
1.0
20
.5
Ft.
VERTICAL
FC
2.0
10
0.2
o
50 Hx25 V
Medium Flood
SPACING FACTOR
20
FC
2.0
7"
(178)
o
N1212
12 Volts, 12 Watts, PAR 36
30 Hx20 V
Narrow Flood
10
Ft.
6.5"
(165)
13.2"
(335)
BATTERY
Nickel-Cadmium
0
Z1225 - 29 lbs. (13 kgs.)
Z1250 - 29 lbs. (13 kgs.)
Z1225N - 18 lbs. (8 kgs.)
Z1250N - 18 lbs. (8 kgs.)
Z1275N - 20 lbs. (9 kgs.)
Z12100N - 29 lbs. (13 kgs.)
Z12125N - 29 lbs. (13 kgs.)
Z12120 - 22 lbs. (10 kgs.)
1.0
VERTICAL
.5
20
10
5
20
0
1.0
0.5
0.3
0.2
20
5
40
80
10
SPACING
(FT)
0
60
GROSS LUMEN
OUTPUT
110
10
10
20
30
40
REPLACEMENT LAMP #7613
50
20
1.0
0.5
0.3
0.2
25
10
40
60
80
SPACING
(FT)
GROSS LUMEN
OUTPUT
177
20
15
Ft.
30
45
60
75
Ft.
REPLACEMENT LAMP #4044
Lithonia Lighting
Sheet #: Z
©1999 Acuity Brands Lighting, Inc., Rev. 10/16/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
CONSTRUCTION
Explosion-proof Emergency Lighting Units
Copper-free cast-aluminum enclosure withstands explosions generated by internal arc without propagating them into the hazardous atmosphere.
Suitable for use in Class I, Div. I, Groups C & D, Zones 0, 1 & 2, Groups IIA, IIB + H2
& IIC; Class I, Div. 2, Groups C & D, Zone 2, Groups IIA, IIB + H2 & IIC; Class II,
Div.1, Groups E, F & G; Class I, Div. 2, Groups F & G and Class III hazardous
location areas.
ZX
Enclosure and cover constructed separately. Threaded cover allows easy attachment or removal. Enclosure has three threaded openings for 3/4" rigid conduit — one for AC input and two for mounting hazardous fixtures.
All lamps heads and remotes must be ordered and shipped separately. See spec
sheet UE-297 for more details.
6 AND 12 VOLTS
14-85 WATTS
BATTERY
Choice of sealed, maintenance-free nickel-cadmium battery or sealed, maintenance-free lead-calcium battery.
90-minute emergency operation at full light output.
ELECTRONICS
120/277 VAC dual-voltage input with surge-protected, solid-state charging circuitry.
Low-voltage disconnect (LVD) feature disconnects battery prior to unacceptable deep discharge, but not before required 90-minute emergency operation.
AC lockout feature prevents battery drain prior to energizing of utility power.
Wiring and electrical connections can be completed without energizing the
emergency circuit.
Brownout protection circuitry automatically switches unit into emergency mode
if utility voltage drops below 20% of nominal.
Battery charging circuitry utilizes constant-current charger for nickel-cadmium
battery units. Fully automatic, voltage-regulated charger used for lead-calcium
battery units. Battery recharge time after full discharge less than required by UL
924 standard.
CODES
UL Listed. Meets UL 924, 844, 1203, 1604, NFPA 70, NFPA 101, NEC and OSHA
illumination standards.
WARRANTY
Three-year total customer satisfaction warranty. For details, see Product Selection Guide.
ORDERING INFORMATION
Family
Voltage3
6V, lead-calcium
ZX685 85 watts 1
(blank) 120/277
6V, nickel-cadmium
ZX614N 14 watts2
ZX628N 28 watts
12V, nickel-cadmium1
ZX1250N 50 watts
Emergency
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ZX614N TD1
Options
KLD
TD1
TD2
Key lock two-way, battery
disconnect for servicing
Time delay 120 VAC
Time delay 277 VAC
Accessories5
Order as separate items.
ELA ZX DRH 12V,12W remote head4
NOTES:
1 Incandescent emergency lamp operation only.
2 Compatible only with ELA ZX remotes (spec sheet UE-297)
using 7-watt compact fluorescent lamps. Will not operate
incandescent lamps. Maximum remote mounting distance is 8'.
3 Some special voltages available. Consult factory.
4 Must be used with ZX1250N unit.
5 See spec sheet UE-297 for other accessories.
Sheet#: ZX
SPUE - 300
ZX Explosion-proof Emergency Lighting Units
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
All dimensions are in inches (millimeters).
Shipping weight:
ZX614N - 63 lbs. (28 kgs.)
ZX628N - 65 lbs. (29 kgs.)
ZX1250N - 67 lbs. (30 kgs.)
ZX685- 69 lbs. (31 kgs.)
120 VAC - .50 amps, 60 watts
277 VAC - .22 amps, 60 watts
OPERATION
DC
Voltage
6
12
Unit
ZX614N
ZX628N
ZX685
1 ½ hrs.
14
28
85
ZX1250N
50
Watts to 87½
of Rated Voltage
2hrs.
4hrs.
10.5
6.75
22.5
14.4
63.75
40.8
37.5
24
8hrs.
14.5
8.5
3-1/2
BATTERY
8-3/4
Lead-Calcium
Voltage
Shelf
Life1
Expected
Life1
Maintenance
6
6 Months
5-8 years
none3
Optimum
Temperature2
60°F–90°F
(16°C–32°C)
All dimensions are in inches (mm).
Includes clearance holes for mounting with 1/2" bolts.
ELA ZX DRH Accessory
Nickel-Cadmium
Voltage
Shelf
Life1
Expected
Life1
Maintenance
6 and 12
3 years
7-9 years
none3
Optimum
Temperature2
4"
(114)
32°F–100°F
(0°C–37.8°C)
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity for 30 to 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
detailed information.
3 Periodic system status test recommended.
10"
(254)
Directional thread
7"
(178)
Directional thread allows for lamp head adjustability.
Lithonia Lighting
Sheet #: ZX
© 1999 Acuity Brands Lighting, Rev. 12/11/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Provides minimum of 90 minutes of illumination for rated wattage upon loss
of AC power. Unique design for light and heavy industrial applications, as
well as heavy commercial environments. Superior performance lamp heads
are ideal for higher mounting heights.
CONSTRUCTION
Rugged front and navy back (std. colors) .140” thick, injection-molded thermoplastic (large back housing is .187” thick, compression-molded composite).
Vertical orientation, designed for pole or column mounting. Also suitable for
wall, I-beam and unistrut mounting. Ceiling and pendant mounting with accessory equipment available on some models. Easy installation with epoxycoated, corrosion-resistant, 12-gauge steel mounting bracket shipped standard. U.S. Patent No. 6,135,624 - Mounting Bracket Utility patent. Conduit entry
points located on top and both sides of unit. Maintenance made easy by toolless lamp replacement, hinged front cover, printed circuit board mounting
shelf and battery belt. U.S. Patent No. D419,097 - Design patent.
LAMPS
U.S. Patent No. 6,193,395 - Lamp Head Utility patent. Full range of lamp options
available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field-adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V
and 12V. Standard lamp is 18W incandescent for 24V.
BATTERY
Sealed, maintenance-free, lead-calcium battery with capacity of 18W to
450W for 90 minutes of emergency operation. Available in 6V, 12V or 24V.
Low voltage disconnect prevents excessively deep discharge that can permanently damage battery.
Premium and Ultimate options offer high-temperature batteries (IND618,
IND1236, and IND12100 only). UL listed from 0° C to 55° C (Premium) or -40° C
to 55° C (Ultimate).
ELECTRONICS
Brownout protection is standard feature of self-diagnostics.
AC/LVD reset prevents battery damage from deep discharge.
Current limiting charger.
Thermal protection prevents overheating and charger failure.
Thermal compensation provides optimum charge voltage relative to ambient temperature.
Dual voltage input capacity 120/277.
Type
Industrial Emergency Lighting Unit
IND6/12/24
6, 12, or 24 Volts
Sealed Lead-Calcium
or Ni-Cad Battery
DIAGNOSTICS (with Select, Premium and Ultimate packages)
US Patent No. 6,502,044 - Self Diagnostics patent.
Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every
six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and
battery condition.
Load learning capability self-calibrates to DC load at first test, enabling it to
detect a lamp failure on future tests. May be re-calibrated at any time by
holding down test switch for 15 seconds.
LISTING
UL Listed. Damp location listing. Meets UL 924, NFPA 101, NFPA 101-NEC and
OSHA illumination standards.
WARRANTY
Three-year total customer satisfaction warranty.
Example:
Family
6 Volts
IND618 18 watts
IND654 54 watts
IND6100 100 watts1
12 Volts
IND1236 36 watts
IND1254 54 watts
IND12100 100 watts
IND12150 150 watts
IND12300 300 watts
IND12450 450 watts
24 Volts
IND24100 100 watts
IND24450 450 watts1
Emergency
Housing Color
(blank) Gray front/
Navy back
W White
Accessories
Order as separate items.
ELA RTT Remote test
transmitter2
ELA WG2M Wire guard - small
(18W-100W)
ELA WGLG Wireguard - large
(150-450W)
ELA BS Banding strap
ELA IND PM Pendant mount kit
for IND618/654/6100
1236/1254/12100/241004
ELA IND CM1 Ceiling mount kit
for IND618
ELA IND CM2 Ceiling mount kit
for IND654/1236/1254
ELA IND CM3 Ceiling mount kit
for IND6100
ELA IND R3 Pre-pack to install
third head
Option Packages
Lamp Type (2 heads)
(blank) Damp location 10° C to 40° C (50° F to 104° F).
XTRA 2 Extra package. Features remote test, time delay
and damp location 10° C to 40° C (50° F to 104° F).
SEL Select package. Features self-diagnostics, time
delay, audible failure indication and damp
location 10° C to 40° C (50° F to 104° F).
PREM3 Premium package. Features high-temperature
ni-cad battery (IND618 and IND1236 only) or high
ambient lead calcium battery (IND12100 only),
self-diagnostics, time delay, audible failure
indication and damp location. UL listed for 0° C to
55° C (32° F to 131° F).
ULT 3 Ultimate package. Features heater, thermostat
and battery blanket with a high temperature nicad battery (IND618 and IND1236 only) or highambient lead-calcium battery (IND12100 only),
self-diagnostics, time delay, audible failure
indication and damp location. UL listed for -40° C
to 55oC (-40° F to 131° F).
6 Volts
PAR36 Composite
(blank) 9W/6V krypton
H1206 12W/6V halogen
H2006 20W/6V halogen
12 Volts
PAR36 Composite
(blank) 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
PAR36 Sealed-Beam
H3512S 35W/12V halogen
H5012S 50W/12V halogen
24 Volts
PAR36 Composite
(blank) 18W/24V incand.
H2024 20W/24V halogen
PAR36 Sealed-Beam
N5024S 50W/24V incand.
IND1236 H1212 ULT
NOTES:
1
2
3
4
DL listed for indoor applications.
Must order a Remote transmitter (ELA RTT). One per job required.
Only available on IND618, IND1236 and IND12100.
ELA IND PM accessory cannot be used with the IND12100 PREM
or IND12100 ULT.
Sheet #: IND6-12-24
INUE-100
IND6-12-24 INDURA Industrial Emergency Lighting Units, 6/12/24 Volts
ELECTRICAL
Primary Circuit
AC Input
Volts Amps Watts
120
.163
19.6
Type
Output
Watts Output
Volts 1-1/2hr. 2hr. 3hrs.
IND618
6
277
120
.069
.172
19.11
20.64
277
120
.075
.171
20.78
20.5
277
120
.064
.174
17.7
20.9
277
120
.078
.174
21.61
20.88
277
120
.078
.174
21.6
20.88
277
120
.074
.359
20.49
43.08
277
120
.168
.290
46.54
34.8
277
120
.130
.33
36.1
39.96
18
6
IND1236
IND1254
IND12100
54
100
75
50
37
12
36
27
18
13
12
54
40
27
20
12
100
75
50
37
150
12
IND24100
IND24450
277
.327
13.25
(336)
16
(406)
16
(406)
Small Housing (18-54W;
100W Standard, XTRA, and SEL)
Small Housing
112
75
8.68
(220)
56
300
225
150
12.5
(317)
12
450
337
225
168
24
100
75
50
37
24
450
337
225
168
ELA IND K0912
.
One (1) 9 Watt Krypton In Vertical, Base Up Position
HORIZONTAL
6
4
4
2
2
1
0
Voltage
Shelf
life
Expected
life1
Maintenance
6/12/24
3 yrs.
10 yrs.
none3
Operating
temperature2
32o-100oF
(0o-37.8oC)
Lead-Calcium
0.5
0.3
0
2
6/12/24
6 mos.
Maintenance
none3
5-8 yrs.
0.3
1
0.5
0.3
6
VERTICAL
VERTICA
VERTICAL
VERTICA
6
6
4
4
2
1
0
0.5
0.3
0
2
2
4
4
6
6
10
1 Based on normal room temperatures and conditions.
2 Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity.
3 Periodic system status test recommended.
0.5
4
6
2
Operating
temperature2
60o-90oF
(16o-32oC)
1
2
4
20
30
40
Ft
Ft.
10
20
30
Ft
Ft.
Center-to-center
spacing* yields 25.5'.
25.5'
FLOOD
IND K0906
Medium Distribution
3'
Center-to-center
spacing* yields 26'.
MEDIUM
SPOT
12-gauge epoxy-coated steel
mounting bracket included with
each unit.
Field-adjusted beam pattern
for composite lamps.
ELA RTT
Order remote transmitter
separately.
*Note: Meets Life Safety Code standard
minimum illuminance of 0.1 FC and
average illuminance of 1.0 FC. Assumes
space of 200'L x 200'W x 30'H, mounting
height: 12', ceiling height: 30', and
reflectances: 10/10/10. Analysis based
on independently tested photometrics.
26'
IND K0912
Medium Distribution
Lithonia Lighting
Sheet #: IND6-12-24
©2004 Acuity Lighting Group, Inc., Rev. 03/06
Acuity Lighting Group, Inc.
Emergency Lighting Systems
One Lithonia Way, Bldg. 3
Conyers, GA 30035
Phone: 800-334-8694
www.lithonia.com
.68
(17)
.
HORIZONTAL
6
Voltage
1 2.16
(25) (55)
0.40
(10)
12.5
(317)
ELA IND K0906
One (1) 9 Watt Krypton In Vertical, Base Up Position
90.58
Expected
life1
8.32
(211)
9
(228)
112
BATTERY
Nickel-Cadmium
Shelf
life
Mounting Bracket
.20(5)
2.48(63)
2.76(70)
IND12450
41.55
92.76
18
(457)
20
8
(203)
IND12300
.15
.773
27
6
12
277
120
40
12
(305)
IND12150
43.77
39.6
6
16
(406)
IND6100
.15
.33
9
IND12150 - 45 lbs.
IND12300 - 72 lbs.
IND12450 - 75 lbs.
IND24100 - 27 lbs.
IND24450 - 75 lbs.
Large Housing (100W
PREM
and ULT; 150-450W)
Large
Housing
IND654
277
120
13.5
4hrs.
All dimensions are in inches (millimeters).
Shipping weight:
IND618 - 13 lbs.
IND654 - 18 lbs.
IND6100 - 23 lbs.
IND1236 - 18 lbs.
IND1254 - 18 lbs.
IND12100 - 27 lbs.
3'
Catalog Number
Notes
FEATURES
INTENDED USE
Provides minimum of 90 minutes of illumination for rated wattage upon loss of AC
power. Unique design for heavy and demanding industrial applications such as
manufacturing plants, refineries, chemical plants, wastewater treatment facilities, food processing facilities, breweries, loading docks, and other applications
subject to hosedown or industrial conditions. Superior performance lamp heads
are ideal for higher mounting heights.
CONSTRUCTION
U.S. Patent No. D505,222 - Design patent. Rugged, heavy-duty, polycarbonate
housing is sealed, gasketed, and corrosion-resistant. Unique vertical orientation is perfect for mounting to a pole, column, wall, I-beam or unistrut. Install
with epoxy-coated, corrosion-resistant, 12-gauge steel mounting bracket
shipped standard. Conduit entry points located at top and on both sides of unit.
U.S. Patent No. 6,135,624 - mounting bracket utility patent. Maintenance is easy
with hinged front cover, printed circuit board mounting shelf and battery belt.
U.S. Patents pending.
LAMPS
U.S. Patent No.6,193,395 - lamp head utility patent. Full range of lamp options
available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field adjustable
beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V and
12V. Standard lamp is 18W incand. for 24V.
BATTERY
Sealed, maintenance-free, lead-calcium battery with capacity of 18W to 125W
for 90 minutes of emergency operation of 6V, 12V or 24V units.
Premium and Ultimate options offer high-temperature batteries (INDX618,
INDX1236, INDX12100 only). UL listed from 0° C to 55° C (Premium) or -40° C to
55° C (Ultimate).
Low voltage disconnect prevents excessively deep discharge that can permanently damage battery.
ELECTRONICS
Brownout protection is a standard feature of self-diagnostics.
AC/LVD reset prevents battery damage from deep discharge.
Current limiting charger.
Dual voltage input capacity (120/277V).
Thermal protection prevents overheating and charger failure.
Thermal compensation provides optimum charge voltage relative to ambient
temperature.
Type
NEMA 4X Emergency Lighting Unit
INDX
6, 12, or 24 Volts
Sealed Lead-Calcium
or Ni-Cad Battery
®
DIAGNOSTICS (with Select, Premium and Ultimate packages)
U.S. Patent No. 6,502,044 - Self-Diagnostics patent.
Test switch provides manual activation of 30 second diagnostic testing (for on
demand visual inspection).
Single multi-chromatic LED indicator displays two-state charging, test activation
and three-state diagnostic status.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every six
months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery
condition.
Load learning capability self-calibrates to DC load at first test, enabling it to
detect a lamp failure on future tests. May be re-calibrated at any time by holding
down test switch for 15 seconds.
LISTING
UL Listed. Meets UL 924, UL50, NFPA 101, NFPA 70-NEC, and OSHA illumination
standards. NEMA 4, 4X rated. IP66 and NSF Listed.
WARRANTY
Three-year total customer satisfaction warranty.
ORDERING INFORMATION
Family
Housing Color
6 Volts
INDX618 18 watts
INDX654 54 watts
INDX6100 100 watts
(blank)
W
Gray
White
12 Volts
INDX1236 36 watts
INDX1254 54 watts
INDX12100 100 watts1
INDX12125 125 watts
24 Volts
INDX24100 100 watts
Accessories
Order as separate items.
ELA RTT Remote test transmitter2 (for use with
XTRA package, remote test option)
ELA WGLG Wireguard - large
ELA BS Banding strap
ELA IND CM2 Ceiling mount kit for INDX654/1236/1254
Emergency
Example: INDX12100 H1212 ULT
Option Packages
Lamp Type (2 heads)
6 Volts
PAR36 Composite
(blank) 9W/6V krypton
H1206 12W/6V halogen
H2006 20W/6V halogen
12 Volts
PAR36 Composite
(blank) 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
PAR36 Sealed-Beam
H3512S 35W/12V halogen
H5012S 50W/12V halogen
24 Volts
PAR36 Composite
(blank) 18W/24V incand.
H2024 20W/24V halogen
PAR36 Sealed-Beam
N5024S 50W/24V incand.
(blank) UL listed to 4X standards.
XTRA2 Extra package features remote test and time delay. UL
listed for 10° C to 40° C (50° F to 104° F).
SEL Select package features self-diagnostics, time delay and
audible failure indication. UL listed for 10° C to 40° C .
PREM3 Premium package features high temperature ni-cad
battery (INDX618 and INDX1236 only) or high ambient
lead calcium battery (INDX12100 only), self-diagnostics,
time delay, audible failure indication. UL listed for 0° C to
55° C (32° F to 131° F).
ULT3 Ultimate package features heater, thermostat and
battery blanket with a high temperature ni-cad battery
(INDX618 and INDX1236 only) or a high-ambient leadcalcium battery (INDX12100 only), self-diagnostics, time
delay and audible failure indication. UL listed for -40° C to
55° C (-40° F to131° F).
NOTES:
1 INDX12100 available with either the PREM or ULT package only.
2 Must order a Remote transmitter (ELA RTT) sold separately. One
per job required.
3 Only available on INDX618, INDX1236 and INDX12100.
Sheet #: INDX
INUE-140
INDX INDURA NEMA 4X Emergency Lighting Units, 6/12/24 Volts
MOUNTING
SPECIFICATIONS
Dimensions : Measured in inches (millimeters).
ELECTRICAL
Primary Circuit
Mounting Bracket
AC Input
Volts Amps Watts
120
.093
19.56
Type
Output
Watts Output
Volts 1-1/2hr. 2hr. 3hrs.
INDX618
277
120
.041
.171
.073
.144
.062
.174
18
13.5
9
6
6
54
40
27
20
6
100
75
50
37.5
12
36
27
18
13
12
54
40
27
20
1 2.16
(25) (55)
8
(203)
16
.20(5)
2.48(63)
2.76(70)
7-1/4
277
120
.078
.174
17.73
20.88
277
120
.078
.160
21.61
20.88
277
120
.072
.160
20.55
20.88
277
120
.072
.33
20.50
39.6
277
.15
41.55
INDX1254
INDX618 - 16 lbs.
INDX654 - 20 lbs.
INDX6100 - 28 lbs.
INDX1236 - 20 lbs.
INDX1254 - 20 lbs.
INDX12100 - 36.5 lbs.
INDX12125 - 30 lbs.
100
75
50
37.5
INDX24100 - 30 lbs.
INDX K0912 9W (MID
(MID)
One 9-Watt Krypton, Vertical Base Up Pos.
INDX K0906 INDURA 4X(NO LENS)
LENS
One 9 Watt Krypton, Horizontal Pos.
HORIZONTAL
HORIZONTAL
12
INDX24100
11-1/2
PHOTOMETRICS
12
INDX12125
.68
(17)
Weight: Measured in pounds (kilograms).
20.22
18.24
INDX1236
INDX121004
6
20.78
20.52
INDX6100
277
120
4hrs.
19.11
20.64
INDX654
277
120
8.32
(211)
0.40
(10)
125
93
62
6
4
46
4
2
2
1
0
0.5
0.3
0
24
100
75
50
1
0.5
1
0.5
2
2
4
37
4
6
VERTICAL
VERTICA
VERTICAL
VERTICA
6
4
4
2
BATTERY
2
1
0
0.5
0.3
0
2
2
Nickel-Cadmium
4
4
Voltage
Shelf
life
Expected
life1
6/12
3 yrs.
10 yrs.
Maintenance
none3
Operating
temperature2
32o-100oF
(0o-37.8oC)
6
10
20
30
40
50
60
Ft.
Ft
10
20
30
40
50
Ft.
Ft
PERFORMANCE DIAGRAMS
Center-to-center
spacing* yields 21'.
Lead-Calcium
Voltage
Shelf
life
Expected
life1
6/12/24
6 mos.
5-8 yrs.
Maintenance
none3
21'
Operating
temperature2
60o-90oF
(16o-32oC)
1
Based on normal room temperatures and conditions.
2
Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and
lower temperatures affect life and capacity.
3
Periodic system status test recommended.
INDX K0906
Medium distribution
Center-to-center
spacing* yields 19'.
6'
19'
*Note: Meets Life Safety Code standard
minimum illuminance of 0.1 FC and average
illuminance of 1.0 FC. Assumes space of 200'L x
200'W, mounting height: 16', ceiling height: 30',
and reflectances: 10/10/10. Analysis based on
independently tested photometrics.
INDX K0912
Medium distribution
6'
KEY FEATURES
FLOOD
MEDIUM
SPOT
ELA RTT
12-gauge epoxy-coated steel
mounting bracket included with
each unit.
Vertical orientation for pole or
column mounting.
Field-adjusted beam pattern for
composite lamps.
Order remote transmitter separately.
Lithonia Lighting
Sheet #: INDX
©2004 Acuity Lighting Group, Inc., Rev. 9/05
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
In Canada: 160 avenue Labrosse, Point-Claire, P.Q. H9R 1A1
www.lithonia.com
Catalog Number
Notes
FEATURES & SPECIFICATIONS
Type
INTENDED USE — Provides a minimum of 90 minutes illumination for rated wattage
upon loss of AC power. Ideal for applications requiring attractive unit equipment with
quick installation and unparalleled performance.
CONSTRUCTION — White, compact, low-profile contemporary design. Engineeringgrade thermoplastic housing is impact-resistant, scratch-resistant and corrosionproof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and
man-made light sources.
Thermoplastic Emergency Light
ELM 6-12
Two 9W wedge-base krypton lamps offer 80 percent more light output than the standard 9W incandescent lamps.
Patented MR24, multi-faceted reflector significantly improves photometric performance – 48 percent more light delivered to the path of egress.
Tool-less access for maintenance. Rigid conduit entry on both top and sides on large
units (ELM654, ELM1254, and ELM1272), and top only for small units (ELM618 and ELM627).
Universal J-box mounting pattern.
HIGH CAPACITY UNITS
Low-profile, integrated test switch/pilot light.
Unique track and swivel arrangement permits full range lamp head adjustment.
US patent No. D-532,918. Patent-pending Quick-Mount for simple installation. Ceiling
mount standard.
BATTERY — Sealed, maintenance-free lead-calcium battery standard.
Sealed, maintenance-free nickel-cadmium battery optional.
Automatic recharge after a 90-minute discharge.
Low-voltage disconnect prevents excessively deep discharge that can permanently
damage the battery.
Single-circuit battery connection.
ELECTRONICS — Universal input voltage capability (120 through 277V, 50 or 60 Hz).
Current-limiting charger maximizes battery life and minimizes energy consumption.
Provides low operating costs.
Short-circuit protection — current-limiting charger circuitry protects printed circuit
board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge voltage
relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide range of line
voltages. Prevents over/undercharging that shortens battery life and reduces capacity.
DIAGNOSTICS (SD option) — Single multi-chromatic LED indicator to display twostate charging, test activation and three-state diagnostic status.
Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30
minutes bi-annually. Automatic test is easily postponed for eight hours by activating
manual test switch. Diagnostic evaluation of lamp, AC to DC transfer, charging and
battery condition. Continuously monitors AC functionality.
Load learning capability self-calibrates to DC load at first test, enabling it to detect a
lamp failure on future tests. It may be recalibrated at any time by holding down the
test switch for 15 seconds.
Filtered charger input minimizes charge voltage ripple and extends battery life.
LISTING — UL listed. Damp Location listing available. Meets UL 924, NFPA 101, NFPA
70-NEC and OSHA illumination standards.
AC/LVD reset allows battery connection before AC power is applied and prevents
battery damage from deep discharge.
WARRANTY — Three-year total customer satisfaction warranty. For details, see the
Product Selection Guide.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELM618
Accessories
Family
Lamp type
ELM618 6V, 18W
ELM627 6V, 27W
ELM654 6V, 54W
ELM1254 12V, 54W
ELM1272 12V, 72W
6-Volt MR 24 Composite
(blank) 9W/6V krypton1
H1206 12W/6V halogen2
H2006 20W/6V halogen3
12-Volt MR 24 Composite4
(blank) 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
Options*
B
N
TD
RT
SD
R0
DL
N0M
Black housing9
Maintenance-free ni-cad battery5
Time delay6
Remote test7
Self-diagnostics6
Less Heads8
Damp Location5,10 - 100 - 400C (500-1040F)
NOM Certified11
ELA LRT
ELA VS2
ELA WG2M
ELA MR24
*Options Availability Guide
Product
ELM618
ELM627
ELM654
ELM1254
ELM1272
Size
S
S
L
L
L
Emergency
SD6
■
■
■
■
■
TD6 RT7 N5 B9
■
■
■ ■ ■ ■
■
■
■
■ ■
■
11
DL5,10 R08 NOM
■ ■
■ ■
■
■ ■
■
NOTES:
1 Available on ELM618, ELM627, and ELM654 only.
2 Available on ELM627 and ELM654 only.
3 Available on ELM654 only.
4 Available on ELM1254 and ELM1272 only.
5 Available on ELM618, ELM627, and ELM1254 only.
6 SD and TD for ELM618 and ELM1254 must be ordered
with N option.
7 RT not available with SD. Need to order the ELA LRT.
Order as separate items.
Remote test (laser) for distances up to 15'
Polycarbonate vandal shield (1/8" thick)
Wireguard
Compact MR24 remote lamp head
ELA MR24 K0606 (6W, 6V krypton)
ELA MR24 K0906 (9W, 6V krypton)
ELA MR24 H1206 (12W, 6V halogen)
ELA MR24 K0912 (9W, 12V krypton)
ELA MR24 H1212 (12W, 12V halogen)
ELA MR24 H2006 (20W, 6V halogen)
ELA MR24 H2012 (20W, 12V halogen)
8 Not available with any other options, except
ELM1272 TD.
9 Available on ELM627 and ELM1272 only.
10 Damp Location listed from 100C to 400C (500 - 1040F)
except ELM618N, ELM627N and ELM1254N listed
from 150C to 320C (600 - 900F).
11 NOM available with ELM618 and ELM1254 only (not
available with any other options).
Sheet #: ELM 6-12
QMUE- 130
ELM 6-12 QUANTUM® Thermoplastic Emergency Light
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are in inches (millimeters).
AC Input Max
Volts Amps Watts
120
.167
5.2
Type
ELM618
277
120
.072
.10
5.6
5.2
277
120
.04
.250
5.6
7.4
277
120
.108
.250
7.4
11
277
120
.108
.250
11.1
11
277
.108
11.1
ELM618 and ELM627 Dimensions
(small housing)
Output
Watts Output
Volts 1-1/2hr. 2hrs. 3hrs. 4hrs.
6
18
13.5
9
3
6
27
20
13.5
10
6
54
40.5
27
20
12
54
40.5
27
20
12
72
54
36
27
ELM627
ELM654
ELM1254
ELM1272
Shipping weight:
ELM618 - 6.8 lbs.
ELM627 - 8.0lbs.
12.79"
(324.9)
7.01"
(180.2)
4.73"
(120.1)
Shipping weight:
ELM654 - 13 lbs.
ELM1254 - 13 lbs.
ELM1272 - 13 lbs.
ELM654, ELM1254, and
ELM1272 Dimensions (large
housing)
12.79"
BATTERY
Nickel-Cadmium
(324.9)
Voltage
Shelf
life1
Expected
life1
Maintenance
6/12
3 yrs.
10 yrs.
none3
Operating
temperature2
32o-100oF
(0o-37.8oC)
7.01"
(180.2)
Sealed Lead-Calcium
Voltage
Shelf
life1
Expected
life1
Maintenance
6/12
1 yr.
5-8 yrs.
none3
5.82"
(147.8)
Operating
temperature2
60-90°F
(16-32°C)
ELM6-12 Backplate
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity to 90
minutes. Higher and lower temperatures affect life and capacity. Consult
factory for detailed information.
3 Periodic system status test recommended.
7.01"
(180.2)
PERFORMANCE DIAGRAMS
12.79"
(324.9)
ELM12 Performance Advantage
33'
• 12-volt, 9-watt krypton lamp
• Typical 10 foot mounting height delivers
33 feet center-to-center spacing
10'
• 48% increase in center-to-center spacings
over competitive 12-volt higher capacity
emergency lighting units.
3'
ELM6 Halogen Performance Advantage
52'
• 6-volt,20-watt halogen lamp
• Higher mounting heights deliver 50+ feet
•
Recommended Center-to-Center Spacing
Lamps
center-to-center spacing
73% increase in center-to-center spacings
over the highest wattage lamphead
available from competitive emergency
lighting units
7.5'
10'
12'
16'
20'
K0606
25'
N/A
N/A
N/A
N/A
K0906
25'
31'
29'
27'
23'
K0912
25'
33'
30'
29'
26'
H1212
N/A
31'
33'
39'
41'
H2006
N/A
35'
37'
52'
49'
Mtg Ht
16'
3'
Lithonia Lighting
Sheet #: ELM 6-12
©2003 Acuity Brands Lighting, Inc., Rev. 5/30/08
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax: 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated
wattage upon loss of AC power. Ideal for applications requiring attractive unit
equipment with quick installation.
CONSTRUCTION — White, compact, low-profile contemporary design with UVstabilized thermoplastic housing that is impact and scratch-resistant.
Two 5.4W wedge-base krypton lamps offer 32 percent more light output than
standard incandescent lamps.
Thermoplastic Emergency Light
ELM
Patent-pending reflector/refractor design significantly improves photometrics.
Dual-voltage input capability (120/277V).
Edge connectors on printed circuit board ensure long-term durability.
Universal J-box mounting pattern.
Lead-Calcium Battery
Low-profile, integrated test switch/pilot light.
Tool-less access for maintenance.
Easily visible bright red status indicator.
Flexible conduit entry provision on top of the unit. Ceiling mount standard.
U.S. Patent No. D483,511
BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W to
18W (CSA) rated capacity.
Automatic 48-hour recharge after a 90-minute discharge.
Low-voltage disconnect prevents excessively deep discharge that can
permanently damage the battery.
Single-circuit battery connection.
Galvanized battery retaining clip.
ELECTRONICS — Current-limiting charger maximizes battery life and minimizes
energy consumption. Provides low operating costs.
Short-circuit protection — current-limiting charger circuitry protects printed
circuit board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to
prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge
voltage relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide range
of line voltages. Prevents over/undercharging that shortens battery life and
reduces capacity.
Filtered charger input minimizes charge voltage ripple and extends battery life.
AC/LVD reset allows battery connection before AC power is applied and prevents
battery damage from deep discharge.
Brownout protection is automatically switched to emergency mode when supply
voltage drops below 80 percent of nominal.
LISTING — UL Listed. NOM Certified. ELM and ELM DL meet UL 924, NFPA 101,
NFPA 70-NEC and OSHA illumination standards. ELM CSR meets UL 1310 and UL73.
WARRANTY — Three-year total customer satisfaction warranty. For details, see
the Product Selection Guide.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELM
ELM
Family
ELM
Options
CSR
DL
Eight-foot cordset (120V)
Damp location listed (10o - 40oC)1
Accessories
Order as separate items.
NOTES:
1 Not available with CSR option.
Emergency
ELA VS Thermoplastic vandal shield
ELA WGST Wireguard
Sheet #: ELM
QMUE - 100
ELM Quantum® Thermoplastic Emergency Light
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are inches (millimeters).
Shipping weight: 3.0 lbs. (1.4 kgs.)
Type
Volts
120
AC Input
Amps Watts
.11
1.2
Output
Volts
ELM
6
277
.12
Watts Output
1/2hr. 1hr. 1-1/2hrs. 2hrs.
*
*
12
11.5"
(292.1)
9
5"
(127)
1.5
* Half hour and one hour run time not applicable for U.S. product.
BATTERY
Sealed Lead-Calcium
Voltage
6
Shelf
life1
6 mos.
3.75"
(95.25)
Expected
life1
Maintenance
5-8 yrs.
none3
Optimum
temperature2
Mounting Plate
60-90°F
(16-32°C)
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity for 30 to 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
detailed information.
3 Periodic system status test recommended.
1.91"
(48.51)
2.5"
(63.5)
5"
3.91"
(127) (99.31)
5.63"
(143)
3.75"
(95.25)
11.5"
(292.1)
LAMP PHOTOMETRICS
FIXTURE PERFORMANCE
Consult factory for photometric information.
Consult factory for fixture performance information.
KEY FEATURES
OPTION
Unit snaps to mounting plate — no additional mechanical fasteners needed.
ELM CSR option with eight-foot cordset.
Lithonia Lighting
Sheet #: ELM
©1991 Acuity Brands Lighting, Inc., Rev. 6/25/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
INTENDED USE — Provides a minimum of 90 minutes of illumination for the
rated wattage upon loss of AC power. Ideal for applications requiring attractive
unit equipment with quick installation.
CONSTRUCTION — White, compact, low-profile contemporary design. Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant and
corrosion-proof. UL94V-O flame rating. UV-stable resin resists discoloration from
natural and man-made light sources.
Two 5.4W wedge-based krypton lamps offer 32 percent more light output than
standard incandescent lamps.
Thermoplastic Emergency Light
ELM2
Patented MR24, multi-faceted reflector significantly improves photometric performance – 60 to 100 percent more light delivered to path of egress.
US Patent No. D484,272
Dual-voltage input capability (120/277V). Edge connectors on printed circuit
board ensure long-term durability.
Lead-Calcium Battery
Low-profile, integrated test switch/pilot light. Easily visible bright red status
indicator.
Unique track-and-swivel arrangement permits full range of direction of lamp head
adjustment. Universal J-box mounting pattern. Tool-less access for maintenance.
Flexible conduit entry provision on top of the unit. Ceiling mount standard.
U.S. Patent No. D473,672
BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W rated
capacity. Automatic 48-hour recharge after a 90-minute discharge.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
Single-circuit battery connection. Galvanized battery retaining clip.
ELECTRONICS — Current-limiting charger maximizes battery life and minimizes
energy consumption. Provides low operating costs.
Short-circuit protection — current-limiting charger circuitry protects printed
circuit board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to
prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide range
of line voltages. Prevents over/undercharging that shortens battery life and
reduces capacity.
DIAGNOSTICS (SD option) — Single multi-chromatic LED indicator to display
two-state charging, test activation and three-state diagnostic status.
Test switch provides manual activation of 30- second diagnostic testing for ondemand visual inspection.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every
six months.
Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition.
Brownout protection is a standard feature of self-diagnostics.
Continuously monitors AC functionality.
AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge.
Automatic test is easily postponed for eight hours by activating manual test
switch.
LISTING — UL Listed and NOM Certified (standard). Meets UL 924, NFPA 101,
NFPA 70-NEC and OSHA illumination standards. Meets Mexican standards.
Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal.
WARRANTY — Three-year total customer satisfaction warranty. For details, see
the Product Selection Guide.
Filtered charger input minimizes charge voltage ripple and extends battery life.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELM2
ELM2
Family
ELM2
Options
B
DL
SD
Black housing1
Damp location listed (10oC to 40oC)1
Self-diagnostics
Accessories
Order as separate item.
NOTES:
1 Black unit not available with damp location option.
Emergency
ELA VS Thermoplastic vandal shield
ELA WGST Wireguard
Sheet #: ELM2
QMUE-120
ELM2 QUANTUM® Thermoplastic Emergency Light
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are inches (millimeters).
Shipping weight: 4.0 lbs. (1.8 kgs.)
Type
AC Input
Amps Watts
.11
1.2
Volts
120
Output
Volts
ELM2
6
277
.12
11.5"
(292.1)
Watts Output
1-1/2hrs. 2hrs.
12
9
5"
(127)
1.5
* Half-hour and one-hour run time not applicable for U.S. product.
BATTERY
3.75"
(95.25)
Sealed Lead-Calcium
Voltage
Shelf
life1
Expected
life1
Maintenance
Optimum
temperature2
6
6 mos.
5-8 yrs.
none3
60-90°F
(16-32°C)
Mounting Plate
1.91"
(48.5)
5"
(127)
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity for 30 to 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
detailed information.
3 Periodic system status test recommended.
2.5"
(63.5)
3.91"
(99.3)
5.63"
(143)
3.5"
(88.9)
11.5"
(292.1)
3.75"
(95.25)
12.5"
(317.5)
FIXTURE PERFORMANCE
LAMP PHOTOMETRICS
LTL10586
MR24 K0606
6-volts, 5.4-watts krypton
Center-to-Center
Spacing*
yields 20'
HORIZONTAL
6
4
Single-Unit
Coverage*
yields 18'
2
1
0
0.5
0.3
0.1 FC min.
2
1 FC average
4
6
VERTICAL
6
4
18 ft.
2
1
0
0.5
6-Foot Path of Egress
0.3
6 ft.
2
4
6
10
20
Ft.
Center-to-Center
Spacing*
yields 25'
SPACING/COVERAGE GUIDE
MR24 K0606
Lamp
Path of Egress
3'-wide
6'-wide
Center-to-Center
Spacing
25'
20'
Single-Unit
Coverage
24'
18'
0.1 FC min.
Single-Unit
Coverage*
yields 24'
1 FC average
24 ft.
3-Foot Path of Egress
3 ft.
* Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance
of 1.0 FC. Assumes open space with no obstructions, mounting height: 7.5’, ceiling height: 9’,
and reflectances: 80/50/20. Analysis based on independently tested photometrics.
Lithonia Lighting
Sheet #: ELM2
© 1991 Acuity Brands Lighting, Inc., Rev. 6/25/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Guideline Specification
Electronics
General
TM
The emergency lighting unit shall be of the Affinity
family manufactured by Lithonia Emergency Systems.
It shall conform to the requirements of the UL924 standards.
Housing
Construction: The unit housing shall be a die-cast aluminum, tear-shaped housing (U.S. Patent no. D468.046).
Dimensions shall not exceed 6-1/2” W x 9-1/2” H x 27/10” D.
Mounting: Unit shall be wall-mounted. Universal Jbox mounting pattern should be provided. A conduit
entry point shallbe located on top of the unit.
Maintenance: Unit shall be maintained easily with a
single tool entry.
Color: The housing color shall be specified as brushed
nickel or polyester powder coat textured paint in white,
black, or dark bronze.
Optical System
The patent-pending reflector/refractor design shall feature vac-metalized, die-casted reflectors; a highly transmissive, multi-faceted refractor; and two 6-watt, wedgebased, xenon lamps rated for 105 lumens. It shall deliver spacing at 26’ on center* to meet the Life Safety
Code of one foot candle average and 0.1 foot candle
minimum, as well as the max-to-min ratio of 40:1.
* Assumes open space with no obstructions, 3’-wide
path of egress, 8.5’ mounting height, 9’ ceiling height,
and 80/50/20 reflectances.
Battery
Batteries shall be 6-volt, sealed, maintenance-free, lead
calcium or high-temperature nickel cadmium -- providing 12-watt rated capacity for 90 minutes of emergency
operation.
The electronics shall include AC/LVD reset, which
allows battery connection before AC power is initially applied and prevents battery damage from deep
discharge. The electronics shall also include brownout protection and DC fuse and a solid-state charger
that provides automatic recharge after a discharge.
The circuitry shall provide thermal protection to
sense circuitry temperature and adjust charge current to prevent overheating and charger failure and
thermal compensation to adjust charger output to
provide optimum charge voltage relative to ambient
temperature.
Self-Diagnostics (Premium and Exterior Option Packages)
The patented (U.S. Patent No. 6,502,044) self-diagnostics shall provide a single multi-chromatic LED
indicator to display two-state charging, test activation and three-state diagnostic status. And a test
switch that provides manual activation of 30-second diagnostic testing for on-demand visual inspection. The self-diagnostic testing will occur for five
minutes every 30 days and 30 minutes every six
months for diagnostic evaluation of lamps, AC to
DC transfer, charging and battery condition. This option will continuously monitor AC functionality.
Option Packages
Premium Package: Includes high-temperature, nicad battery, self-diagnostics, and damp location listing from 0o C to 50o C.
Exterior Package: Includes high-temperature, ni-cad
battery, self-diagnostics, and wet location listing
from -18o C to 50o C (0o F to 122o F).
Warranty
A warranty for three-year total customer satisfaction shall be included.
Lithonia Lighting
Form No. 680.211
Rev. 08/03
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE — Provides a minimum of 90 minutes illumination for the rated
wattage upon loss of AC power. Ideal for applications requiring low-profile,
attractive emergency lighting.
®
CONSTRUCTION — Compact, low-profile, architectural design with die-cast aluminum housing that has a contemporary brushed nickel-plated finish. Other
available finishes are texturized polyester powder coat paint in white, black and
dark bronze. All finishes can be painted in the field to match the wall color of
choice.
Die-Cast Architectural Emergency Light
AFN
U.S. Patent No. D468,046.
Two 6W wedge-base xenon lamps offer 55 percent more light output than
standard incandescent lamps. Meets requirements for NEC 700.16.
Patent-pending reflector/refractor design features superior vac-metalized, diecasted reflectors; and multi-faceted, highly transmissive refractor that significantly improve photometrics.
Dual-voltage input capability (120/277V).
Edge connectors on printed circuit board ensure long-term durability.
Universal J-box mounting pattern.
Low-profile, integrated test switch/pilot light located below the lens.
Easily visible green status indicator.
Rigid conduit entry provision on top of the unit.
BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W rated
capacity. Nickel-cadmium battery with Premium and Exterior option packages.
Automatic 48-hour recharge after a 90-minute discharge.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection.
ELECTRONICS — Current-limiting charger maximizes battery life and minimizes
energy consumption. Provides low operating costs.
Short-circuit protection — current-limiting charger circuitry protects printed
circuit board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to
prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide range
of line voltages. Prevents over/undercharging that shortens battery life and
reduces capacity.
Filtered charger input minimizes charge voltage ripple and extends battery life.
AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge.
Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal.
ORDERING INFORMATION
SELF-DIAGNOSTICS (SD option)
Patented Electronics - U.S. Patent No. 6,502,044.
Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status.
Test switch provides manual activation of 30-second diagnostic testing for
on-demand visual inspection.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every
six months.
Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality.
Postpone automatic test initiates eight hour delay of an automatic test by
activating the manual test switch.
LISTING — UL listed. Wet location (EXT) listed. Damp location (PREM, EXT)
listed. Cold weather (EXT) listed.
Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. UL
labeled.
WARRANTY — Three-year warranty.
For shortest lead times, configure product using standard options (shown in bold).
Example: AFN W EXT
AFN
Family
AFN Affinity Series die-cast architectural emergency lighting
Finish
W White
B Black
BN Brushed nickel
DB Dark bronze1
Option packages
(blank) Features lead calcium battery
PREM
Features ni-cad battery, self-diagnostics and damp location 0° to
50°C (32° to 122°F)
EXT Features high-temperature ni-cad battery listed from -18° to
50°C (0° to 122°F), self-diagnostics. Listed for cold weather,
damp and wet location
T D Time delay2
NOTES:
1 Dark bronze can only be ordered with EXT option. This
finish will not be available on other units.
2 Only available in black EXT option.
Emergency
Accessories
Order as separate item.
ELA AFNR DB
Remote fixture (less batteries and electronics) to be powered
by 6V battery equipment as part of an emergency lighting
system (listed from -18oC to 50oC), W, B finishes available.2
Sheet #: AFN
ARC-60
AFN Affinity® Die-Cast Architectural Emergency Light
FIXTURE PERFORMANCE
SPECIFICATIONS
ELECTRICAL
Primary Circuit
AC Input
Volts Amps Watts
120
.11
1.1
Type
Output
Volts
AFN
6
277
120
.12
.15
1.3
1.4
277
120
.14
.23
1.4
21
AFN PREM
AFN EXT
277
.25
Center-to-Center Spacing
on a 3-foot Path of Egress
Watts Output
1-1/2hrs.
26 ft
.
12
1 FC average
6
12
6
12
0.1 FC min.
35
BATTERY
Sealed Lead-Calcium
3 ft.
Voltage
Shelf
life1
Expected
life1
Maintenance
Optimum
temperature2
6
6 mos.
5-8 yrs.
none3
60-90°F
(16-32°C)
Center-to-Center Spacing
on a 6-foot Path of Egress
21 ft.
Nickel-Cadmium
Voltage
Shelf
life1
Expected
life1
Maintenance
Optimum
temperature2
6
3 yrs.
7-9 yrs.
none 3
32-122°F
(0-50°C)
1 FC average
1 At 77°F (25°C).
2 Optimum ambient temperature range where unit will provide capacity for 90
minutes. Higher and lower temperatures affect life and capacity. See option
packages for expanded temperature ranges. Consult factory for detailed
information.
3 Periodic system status test recommended.
0.1 FC min.
6 ft.
MOUNTING
SPACING GUIDE
All dimensions are inches (millimeters).
Shipping weight: 3.5 lbs. (1.59 kgs.)
2-7/10
(68.58)
4 3/8
(85.73)
9-1/2
(241.3)
2-7/10
(68.58)
4 3/8
(85.73)
9-1/2
(241.3)
6-1/2
(165.1)
9-1/2
(241.3)
Xenon
Lamp
Path of Egress
3'-wide
Path of Egress
6'-wide
Center-to-Center
Spacing
26'
21'
NOTE: Meets Life Safety Code standard minimum illuminance of 0.1 FC and
average illuminance of 1.0 FC. Assumes open space with no obstructions,
mounting height: 8.5', ceiling height: 9', and reflectances: 80/50/20.
6-1/2
(165.1)
Test switch
status indicator
Lithonia Lighting
Sheet #: AFN
© 2003 Acuity Brands Lighting, Inc., Rev. 9/28/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax: 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
CONSTRUCTION
Contemporary Cylinder Emergency Light
Black 16-gauge steel backplate and housing.
Contemporary white plastic cylinder shroud with high temperature plastic
optical lens. Both are UV stabilized.
Sturdy adjustable cast-aluminum swivel.
ELCC
One 8W halogen wedge-base lamp (single) or two 6W halogen wedge-base
lamps (twin).
Wall or ceiling mount.
LEAD-CALCIUM BATTERY
Dual-voltage input capability (120V or 277V).
Test switch provides manual activation of functional testing. Status indicator provides visual monitoring of normal AC power.
BATTERY
Sealed, maintenance-free lead-calcium battery provides 12W rated capacity.
Automatic recharge after a 90-minute discharge.
Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
ELECTRONICS
Brownout protection.
Current-limiting charger maximizes battery life and minimizes energy
consumption.
Short-circuit protection — current-limiting charger circuitry protects
printed circuit board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure.
Regulated charge voltage maintains constant-charge voltage over a wide
range of line voltages. Prevents over/undercharging that shortens battery
life and reduces capacity.
AC/LVD allows battery connection before AC power is applied and prevents battery damage from deep discharge. Unit should not be left in reset
mode for more than 72 hours.
CODES
UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NFPA 70 – NEC.
WARRANTY
Three-year total customer satisfaction warranty. For details, see Product
Selection Guide.
ORDERING INFORMATION
For shortest lead times, configure product using standard options (shown in bold).
Example: ELCC
ELCC
Family
ELCC
Options
(blank)
T
Emergency
Single lamp head
Twin lamp heads
Sheet#: ELCC
SPUE-130
ELCC Emergency Light, Contemporary Cylinder
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
Primary Circuit
All dimensions are in inches (millimeters).
Supply
voltage
120
277
AC input
watts
5.8
5.9
Max.
amps
.052
.023
VA
6.2
6.4
BATTERY
Sealed Lead-Calcium
Voltage
Shelf
life1
Expected
life1
Maintenance
Optimum
temperature 2
6
6 mos.
5–8 yrs.
none 3
60–90°F
1 At 77°F.
2 Optimum ambient temperature range where unit will provide capacity for 90 minutes.
Higher and lower temperatures affect life and capacity. Consult factory for detailed
information.
3 Periodic system status test recommended.
4-1/2
(114)
4-1/2
(114)
Lithonia Lighting
Sheet #: ELCC
© 1998 Acuity Brands Lighting, Inc., Rev. 11/8/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
INTENDED USE
Emergency Recessed Series
Provides 90 minutes of illumination for the rated wattage upon the loss of AC
power. Ideal for applications that require attractive unit equipment or when
wall mounting is undesirable.
CONSTRUCTION
ELR2/ELR2P/ELR4
Durable polycarbonate faceplate finished in architectural white.
Hinged faceplate and adjustable mounting hardware speed up and simplify
installation/maintenance.
Two 8W (ELR2) or two 12W glass sealed-beam lamps. Heads rotate 359° to
meet aiming requirements. Dual-voltage input capability (120V or 277V).
6-Volt, Self-Contained, 12-Volt, 50-Watt
U.S. Patent No. 6,502,044.
BATTERY
Sealed, maintenance-free lead-calcium battery provides 16W (ELR2) or
50W (ELR4) rated capacity. Optional nickel-cadmium battery provides 16
watts (ELR2 N) or 24 watts (ELR2P N). Ensures long life over wide temperature ranges.
Automatic battery recharge after 90-minute discharge.
Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
Slip-on battery terminals.
ELECTRONICS
Brownout protection standard on ELR4.
Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs.
Short-circuit protection – current-limiting charger circuitry and fused output circuit (ELR4) protect printed circuit board from shorts.
Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge
voltage relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide
range of line voltages. Prevents over/under charging that shortens battery
life and reduces capacity.
Filtered charger output minimizes charge voltage ripple and extends battery life.
AC/LVD reset allows battery connection before AC power is applied and
prevents battery damage due to deep discharge.
DIAGNOSTICS (SD Option)
Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status.
Test switch provides manual activation of 30-second diagnostic testing for
ORDERING INFORMATION
on-demand visual inspection. Self-diagnostic testing for five minutes every
30 days and 30 minutes every six months.
Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Brownout protection is a standard feature of self diagnostics. Continuously monitors AC functionality.
Automatic test is easily postponed for eight hours by activating manual test
switch. Load-learning capability self-calibrates to DC load at first test enabling it to detect a lamp failure on future tests. It may be recalibrated at any
time by holding down the test switch for 15 seconds.
INSTALLATION
Wall or ceiling mount. Exposed or concealed suspension ceiling systems.
Suitable for use in air-handling plenums.
21-gauge galvanized mounting box fits into opening (10-7/10" H x 10-7/10" W x
3-1/2" D). T-bar clips secure unit to grid in ceiling-mount applications. All
hardware supplied.
T-bar clips secure unit to grid in ceiling-mount applications.
LISTING
UL listed. Meets UL924, NFPA 101-1985 (current Life Safety Code) and NEC
and OSHA illumination standards.
WARRANTY
Three-year total customer satisfaction warranty. For complete details, see
warranty sheet in Product Selection Guide.
Lead times will vary depending on options selected. Consult with your sales representative.
Example: ELR2
Options
Family
ELR2
ELR2P
ELR4
6V, 16W
6V, 24W1
12V, 50W
Emergency
TD
AM
VM
220V/50HZ
H
N1812
N2512
R0
N
CDS
SD
Integral time delay (18 minutes) 2,3
Ammeter 2
Voltmeter 2
220 or 240V, 50 or 60 Hz input
Two 8W halogen lamp heads
Two 18W, 12V incandescent lamp heads3
Two 25W, 12V incandescent lamp heads3
Less lamp heads
Maintenance-free nickel-cadmium battery 4
Compact designer square lamp heads
Self-diagnostics 3
NOTES:
1 Available with nickel-cadmium battery only.
2 Choice of two. Not available with AM, VM and TD on one unit.
3 ELR4 only.
4 Not available with ELR4.
Sheet #: ELR2-2P-4
SPUE-100
ELR2/ELR2P/ELR4 Emergency Recessed Series
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
Primary Circuit
All dimensions are inches (millimeters), unless otherwise specified.
Shipping Weight:
AC Input
Volts Amps Watts
120 .167
20
Type
277
120
.072
.250
20
30
277
.108
30
Watts Output1
1-1/2hrs. 2hrs. 3hrs. 4hrs.
Output
Volts
ELR2
ELR4
ELR2 16 lbs. (7.3 kgs.)
ELR4 22.5 lbs. (10.2 kgs.)
6
16
-
-
-
12
50
38
25
18
BATTERY
Sealed Lead-Calcium
Voltage
ELR2
6
ELR4 12
Shelf
life2
Expected
life2
Maintenance
Optimum
temperature 3
6 mos.
5-8 yrs.
none 4
60o-90 o F
Shelf
life2
Expected
life2
Maintenance
Optimum
temperature 3
3 yrs.
10 yrs.
none 4
32 o -100o F
Nickel-Cadmium
Voltage
ELR2
6
ELR2P N 6
1 Watts to 87-1/2% of nominal voltage.
2 At 77°C.
3 Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
more details.
4 Periodic system status test recommended.
PHOTOMETRICS
30oHx20oV
Narrow Flood
N0806
6 Volts, 8 Watts, PAR 36
HORIZONTAL
SPACING FACTOR
10
FC
2.0
5
0
1.0
0.5
0.3
20
0
1.5
5
1.0
0.5
0.3
0.2
1.5
10
1.0
20
.5
Ft.
VERTICAL
10
50oHx25oV
Medium Flood
SPACING FACTOR
FC
2.0
10
0.2
10
Ft.
N1212
12 Volts, 12 Watts, PAR 36
HORIZONTAL
1.0
VERTICAL
.5
20
5
20
0
1.0
0.5
0.3
0.2
20
5
40
80
10
SPACING
(FT)
0
60
GROSS LUMEN
OUTPUT
110
10
10
20
30
40
50
REPLACEMENT LAMP #7613
Ft.
20
1.0
0.5
0.3
0.2
20
10
40
60
80
SPACING
(FT)
GROSS LUMEN
OUTPUT
177
20
15
30
45
60
75
Ft.
REPLACEMENT LAMP #4044
KEY FEATURES
SELF-DIAGNOSTICS OPTION
z Five-minute test every 30 days
z 30-minute test every six months
z Diagnostics evaluate the battery, lamp,
charger and AC to DC transfer.
Ceiling mount – mounts to T-bar by adjustable bar hangers.
Wall mount – mounts to wood or metal
studs with bar hangers. Also, rough-in
for dry walls.
Condition
Normal mode
Self-testing
Emergency mode
Hi-charge
Battery failure
Lamp failure
Circuit failure
Indication
Steady green
Flashing green
Off
Steady red
Single-flash red
Double-flash red
Triple-flash red
Lithonia Lighting
Sheet #: ELR2-2P-4
©1997 Acuity Brands Lighting, Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
CONSTRUCTION
Emergency Recessed Gimbal
Dual-voltage input capability (120V or 277V).
All-metal housing and gimbal assembly.
ELRG
Matte white baked enamel finish.
High-output 8-watt halogen lamp head.
Lamp adjusts in two planes to 26°.
Low profile pilot light and test switch.
Approved for use in air handling plenums.
Emergency Operation
Comes standard with bar hangers.
BATTERY
Sealed, maintenance-free lead calcium battery provides 10 watts rated
capacity.
24-hour recharge after 90-minute discharge.
Low voltage disconnect prevents excessively deep discharge that permanently
damages the battery.
ELECTRONICS
Current limiting charger maximizes battery life and minimizes energy
consumption.
Short-circuit protection. Current limiting charger circuitry protects printed circuit
board from shorts.
Thermal protection senses circuit, temperature and adjusts charge current to
prevent overheating and charger failure.
Regulated charge voltage maintains constant charge voltage over a wide range
of line voltages. Prevents over/under charging that shortens battery life and
reduces capacity.
Brownout protection
AC/LVD — allows battery connection before AC power is applied and prevents
battery damage from deep discharge. Unit should not be left in reset mode for
more than 72 hours.
CODES
UL listed. Meets UL924, NFPA 101 (current Life Safety Code) and NFPA 70-NEC.
WARRANTY
Three-year warranty.
ORDERING INFORMATION
All configurations of this product are considered "standard" and have short lead times.
Example: ELRG
Family
ELRG
Emergency lighting
recessed gimbal
Emergency
Sheet #: ELRG
SPUE-120
ELRG Emergency Recessed Gimbal
SPECIFICATIONS
DIMENSIONS
Length: 8-3/8 (213)
ELECTRICAL
Width: 8-3/8 (213)
Primary Circuit
Depth: 8-1/4 (210)
Weight: 6.5lbs (3kgs.)
Supply
voltage
AC input
watts
Max.
amps
VA
120
277
5.8
5.9
.052
.023
6.2
6.4
All dimensions are inches (millimeters) unless otherwise specified.
BATTERY
Sealed Lead-Calcium
Voltage
Shelf
life1
Expected
Optimum
life1
Maintenance temperature 2
6
6 Months
5–8 years
none 3
60–90°F
NOTES:
1 At 77°F.
2 Optimum ambient temperature range where unit will provide capacity for 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory
for detailed information.
3 Periodic system status test recommended.
PHOTOMETRICS
ELRG
6-volts, 8 watts, halogen
HORIZONTAL
4
2
0
1
0.5
0.3
1
0.5
0.3
20
30
2
4
VERTICAL
4
2
0
2
4
10
Ft.
Replacement Lamp # 785
Lithonia Lighting
Sheet #: ELRG
©1997 Acuity Brands Lighting, Inc., Rev. 1/2/08
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax: 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
SPECIFICATIONS
INTENDED USE
Ideal for applications requiring unobtrusive, emergency lighting. Available
flushed, semi-recessed or recessed.
CONSTRUCTION
Unobtrusive, contemporary housing design with ivory white Lexan® frame and
black Noryl®* base is impact- and fire-resistant (UL 94V-0 flame rating).
Efficient 10W or two 8W (with 2L option) tungsten halogen lamps provide high
lumen output.
White cone reflector and acrylic prismatic lens (Lexan lens with 2L option)
provide wide beam spread.
Mitered corners and recessed lens give a clean, finished appearance.
Push-to-test lens conceals test switch and "ready" light.
Dual-voltage input (120V or 277V).
BATTERY
Sealed, maintenance-free lead-calcium battery provides 10W (ELSQ) or 20W
(ELSQM) rated capacity.
Automatic battery recharge after 90-minute discharge (120-minute discharge
with 2L option).
Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
Slip-on battery terminals.
ELECTRONICS
Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs.
Thermal protection senses temperature and adjusts charge current to prevent
overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature.
Regulated charge voltage maintains constant-charge voltage over a wide range
of line voltages. Prevents over/under charging that shortens battery life and
reduces capacity.
Filtered charger output minimizes charge voltage ripple and extends battery
life.
AC/LVD reset permits testing of unit at time of installation and ensures full 90minute discharge.
80% brownout protection and high charge indicator (2L option only).
MOUNTING
Wall or ceiling mount.
J-box mounting pattern.
ORDERING INFORMATION
Family
ELSQ 6V, self-contained
ELSQM 6V, 20W
Emergency Square Series
ELSQ/ELSQM
6-Volt, Self-Contained
6-Volt, 20-Watt
Surface mounting standard. For semi-recessed and fully recessed, order
accessory kits ELA SRK and ELA FRK, respectively. All hardware supplied.
LISTING
UL listed. Meets current Life Safety Code, NEC and OSHA illumination standards.
WARRANTY
Three-year warranty.
* Lexan and Noryl are registered trademarks of G.E.
For shortest lead times, configure product using standard options (shown in bold).
Example: ELSQ
Options
2L Two 8W lamps with Lexan lens and
high charge indicator (ELSQM only)1
LEX Lexan lens (standard with 2L option)
N Maintenance-free nickel-cadmium
battery 1
Accessories
Order as separate items.
ELA SRK Semi-recessed kit
ELA FRK Fully-recessed kit
NOTES:
1 2L option is UL listed for a two-hour run time, not available with nickelcadmium battery.
Emergency
Sheet #: ELSQ M
SPUE - 110
ELSQ/ELSQM Emergency Square Series
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
All dimensions are inches (millimeters), unless otherwise specified.
Primary Circuit
AC Input
Volts Amps Watts
120 .092
20
Type
Output
Volts
ELSQ
277
120
.042
.092
20
20
277
.042
20
ELSQM
Watts Output1
1-1/2hrs. 2hrs. 3hrs.
6
10
-
-
6
20
16
10
Shipping Weight:
ELSQ 5 lbs. (2.3 kgs.)
ELSQM 6.5 lbs. (3 kgs.)
BATTERY
Sealed Lead-Calcium
Voltage
6
Shelf
life2
6 mos.
Expected
life2
5-8 yrs.
Maintenance
none 4
Optimum
temperature 3
60 o-90 oF
Expected
life2
5-8 yrs.
Maintenance
none 4
Optimum
temperature 3
32 o-100oF
Sealed Nickel-Cadmium
Voltage
6
1
2
3
4
Shelf
life2
3 yrs.
Watts to 87-1/2% of 6V.
At 77°C.
Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory
for more details.
Periodic system status test recommended.
Rated Output Capacity in Watts - Emergency Run Time
ELSQ N
ELSQM N
1.5 hrs.
10
20
2 hrs.
-15
3 hrs.
-10
KEY FEATURES
Semi-recessed mounting
accessory kit – ELA SRK.
Fully-recessed mounting
accessory kit – ELA FRK.
Lithonia Lighting
Sheet #: ELSQ M
©1997 Acuity Brands Lighting, Inc., Rev. 9/28/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax: 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES & SPECIFICATIONS
INTENDED USE
Provides a minimum of 90-minutes of illumination for the rated wattage upon
the loss of AC power. Ideal for applications that require ensconced emergency lighting in wall or ceiling.
CONSTRUCTION
Trim and door panels finished in durable white textured powder coated
paint. Can be wall papered or field painted.
Trim and panel doors lay flush with mounting surface. No exposed hardware.
Low profile recessed test switch and status indicator configuration minimizes exposed interfaces.
Rugged, 22 GA galvanized steel box with three 3/4" knock-outs.
Galvanized bar hangers span up to 30" on center.
Vertically adjustable bar hangers allows for flush mounting of trims to ceiling
face, accomodates ceiling or walls up to 5/8" thick.
LAMPS
Two MR16 halogen 12W to 75W lamps. Fully adjustable to meet aiming requirements.
Lamps are ensconced until activated in the emergency mode.
Models with additional wattage capacity are provided with fused remote
output leads.
BATTERY
Sealed, maintenance-free lead-calcium battery with capacity of 24W to
150W for a minimum of 90-minutes of emergency operation. Optional nickelcadmium battery.
Extended runtimes available. (See chart on reverse side.)
Automatically recharges after a 90-minute discharge.
Low voltage disconnect prevents excessively deep discharge that can
permanently damage the battery.
Voltage polarity protected connector for reverse polarity protection.
INSTALLATION
Wall or ceiling mount. Exposed or concealed suspension ceiling systems.
T-bar clips secure unit to grid in ceiling-mount applications.
Rough-in dimensions: 13-1/2" x 6-3/4. Allow 5-1/2" for door panel opening clearance.
ELECTRONICS
Dual-voltage input capability (120/277V).
Precision controlled motor and cam system ensures reliable extraction
and retraction of light sources.
Single, multi-chromatic LED indicator to display two-state charging, test
activation and four-state diagnostic status.
ORDERING INFORMATION
Concealed Emergency Lighting Unit
VELARÉ
12-VOLT SELF-DIAGNOSTIC, SEALED LEAD-CALCIUM OR NI-CAD BATTERY
Test switch provides manual activation of 30-second diagnostic testing for
on-demand visual inspection.
Self-diagnostics is provided as a standard feature. The diagnostic feature
tests the unit once every 28 days by opening the doors for 1 second and then
closing them, without turning the lamps on. Following this, a load test will be
performed for 29 minutes checking for lamp, battery or transfer default. The
charger function is monitored continuously.
Diagnostic evaluation of lamp, AC to DC transfer, charging and battery
condition. Continuously monitors AC functionalilty.
IR receiver is provided as a standard feature. Requires the ELA RTVEL
hand-held remote transmitter for remote testing (see accessories) for operation. Selectable 30-second or 90-minute testing.
LISTING
UL listed. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards.
WARRANTY
Three-year warranty.
For shortest lead times, configure product using standard options (shown in bold).
Example: VEL1270 H3512
Family1
Lamp Type4
Options
VEL1224 (12V, 24W)
VEL1240 (12V, 40W)
H1212 12W/12V halogen MR16
H2012 20W/12V halogen MR16
N Maintenance-free ni-cad
T D Time delay
LRIS Less rough-in section5
VEL1270 (12V, 70W)2
VEL12100 (12V,
100W) 3
VEL12150 (12V,
150W) 3
H3512 35W/12V halogen MR16
H5012 50W/12V halogen MR16
H7512 75W/12V halogen MR16
NOTES:
1 For extended run-time information, see chart on reverse side.
2 Not available with H1212 lamps.
3 Not available with H1212 or H2012 lamps.
4 Two lamps provided. Total lamp load cannot exceed the fixture
capacity rating.
5 VEL rough-in section ships standard with fixture unless LRIS
suffix is specified. The rough-in section ships in a separate
carton.
6 Minimum one per job required for remote testing.
Emergency
Accessories
Order as separate items.
ELA RTVEL Remote infra-red hand-held
transmitter with selectable 30second or 90-minute testing6
ELA VEL RIS VEL rough-in section (supplied
standard with fixture unless
LRIS suffix is specified) ships
with mounting hardware only.
Order ELA VEL RIS if needed
for rough-in phase of
construction
Sheet #: VEL
ARC-20
VEL Concealed Emergency Lighting Unit, Velaré
SPECIFICATIONS
DIMENSIONS
ELECTRICAL
All dimensions are in inches (millimeters), unless
otherwise specified.
Shipping Weight:
VEL1224 H1212 LRIS (12V, 24W) - 12.5 lbs.
VEL1240 H2012 LRIS (12V, 40W) - 12.5 lbs.
VEL1270 H3512 LRIS (12V, 70W) - 15 lbs.
VEL12100 H5012 LRIS (12V, 100W) - 15 lbs.
VEL12150 H7512 LRIS (12V, 150W) - 19.5 lbs.
ELA VEL RIS (rough-in) - 11 lbs.
Primary Circuit
AC Input Max Output
Type
Volts Amps Watts
120
.20
30
VEL1224
277
.20
30
Watts
Volts
Output
1-1/2hr.
12
24
12
40
120
.20
30
277
.20
30
VEL1270
120
277
.20
.20
30
30
12
70
VEL12100
120
277
.20
.20
30
30
12
100
VEL12150
120
277
.20
.20
30
30
12
150
VEL1240
Rough-in opening: 13-1/2 (341) x 6-3/4 (170)
Overlap trim:
14-7/16 (365) x 7-5/8 (193)
Allow 5-1/2" for door panel opening clearance.
13 1/2” to 30”
16”
Universal, Adjustable
Mounting Rails
2 per unit
Mount on 13 ½”
or 16” sides.
Depth Behind Wall
For 3/4”
wall thickness = 3 1/4”
Total Depth = 4”
Ceiling / Wall
Thickness =
1/8” to 3/4”
13 1/2”
Rough In
Opening
BATTERY
6 3/4” Rough In
Opening
Sealed Lead-Calcium
Voltage
Shelf
life1
Expected
life1
Maintenance
12
6 mos.
5-8 yrs.
none 2
Operating
temperature
60 o-90 oF
(0o-37.8oC)
Back Box and
Mounting Dimensions
PHOTOMETRICS
NIckel-Cadmium
Recommended Center-to-Center Spacing
Expected
life1
Maintenance
12
3 yrs.
10 yrs.
none 2
Operating
temperature
32-100°F
(16-32°C)
Ceiling Height
Lamp Type
Voltage
Shelf
life1
NOTES:
1 At 77°F (25°C).
2 Periodic system status test recommended.
EXTENDED RUN- TIME CHART
10'
12'
16'
H1212
17'
17'
16'
16'
H2012
36'
36'
34'
34'
64'
20'
H3512
65'
65'
58'
H5012
70'
70'
70'
70'
H7512
130'
140'
134'
140'
Please use the chart below to determine which model number to use to achieve an extended
run time of two, three, or four hours. Example: If you require a 4-hour run time, the lowest
wattage unit available is the VEL1240 H1212. The units are not loaded to full capacity which in
turn extends the run time.
Lamp Wattage
Run-Time Needed
(2) H1212 Lamps
(2) H2012 Lamps (2) H3512 Lamps
65'
(2) H5012 Lamps (2) H7512 Lamps
1-1/2 Hrs. VEL1224 H1212
VEL1240 H2012
VEL1270 H3512
VEL12100 H5012 VEL12150 H7512
2 Hrs. VEL1224 H1212
VEL1240 H2012
VEL1270 H3512
VEL12150 H5012
3 Hrs. VEL1224 H1212 VEL1270 H2012
VEL12100 H3512
VEL1270 H2012
VEL12150 H3512
4 Hrs. VEL1240 H1212
12'
6'
KEY FEATURES
Velare - 35W MR16 at a 12' ceiling height
Meets Life Safety Code standard minimum illuminance of 0.1 FC and average
illuminance of 1.0 FC. Assumes fixture is ceiling mounted in a 200'Wx200'L
open area and reflectances of 80/50/20.
Front Panel
Diagnostic Display
Hi Charge
Float/Full Charge
90
Min.
30
Sec.
Note: All spacings are intended to be guidelines. Results will vary if
application deviates from dimensions or assumptions stated above.
Diagnostic Functions
Battery Failure
Lamp Failure
Transfer Failure
Charger Failure
Door Failure
In test
Self Diagnostics is standard
Motor and cam system
Remote transmitter
hand-held accessory
Lithonia Lighting
Sheet #: VEL
©2005 Acuity Brands Lighting, Inc., Rev. 9/28/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax: 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
INTENDED USE
Ideal for applications where steel housing or metal lamp heads are a requirement.
CONSTRUCTION
18-gauge steel housing finished in instrument tan color.
Hinged faceplate for easy maintenance.
Two 12-watt incandescent glass sealed-beam lamps in thermoplastic housings.
Dual-voltage input capability (120 or 277 volts)
BATTERY
Batteries are sealed, maintenance-free, lead-calcium with wattage capacities of 125, 180 or 275 watts for 90 minutes of emergency operation.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
ELECTRONICS
AC/LVD reset allows battery connection before AC power is applied and
prevents battery damage from deep discharge.
Current limiting charger maximizes battery life and minimizes energy consumption.
Thermal protection senses circuitry temperature and adjust charge current to prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge
voltage relative to ambient temperature.
LISTING
UL listed. Meets UL 924, NFPA 101, NEC and OSHA illumination standards.
WARRANTY
Three-year total customer satisfaction warranty. (For complete details, see
warranty sheet in Product Selection Guide).
ORDERING INFORMATION
Industrial Steel Emergency Lighting
ELT125
ELT180
ELT275
STANDARD LEAD-CALCIUM BATTERY
For shortest lead times, configure product using standard options (shown in bold).
Example: ELT125
Family
Input voltage1
Housing color
Lamp heads
Lamp type
Options
ELT125 125W/12V
(blank) 120V/277V
(blank) Instrument
tan
(blank) Two heads
PAR36 sealed-beam
Ammeter 3
Voltmeter 3
8W halogen lamps
Load disconnect
switch
T D Integral time delay
NOM NOM Certified
ELT180 180W/12V
ELT275 275W/12V
NOTES:
1 Other voltages available. Consult factory.
2 Must be ordered with the MT option.
3 AM and VM must be ordered together.
Emergency
W White
RO Less lamp
heads
MT Metal lamp
heads
(blank) 12W/12V incandescent
N2512
H1212
H3512
H5012
25W/12V
12W/12V
37W/12V
50W/12V
incandescent
halogen
halogen2
halogen2
AM
VM
H
LD
Accessories
Order as separate items.
ELA WG 4/8 Large wireguard (50-275W)
ELA MST Mounting shelf
Sheet #: ELT-125-180-275
INUE-220
ELT125/ELT180/ELT275 Industrial Steel Emergency Lighting
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are inches (millimeters).
Shipping weight:
ELT125 - 43.5 lbs. (19.7 kgs.)
ELT180 - 58.5 lbs. (26.5 kgs.)
ELT275 - 61.5 lbs. (27.9 kgs.)
Type
AC Input
Volts Amps Watts
120
.250
30
Output
Watts Output
Volts 1-1/2hr. 2hr. 3hrs.
ELT125
277
120
.108
.287
30
50
277
120
.125
.287
50
50
277
.125
50
ELT180
ELT275
4hrs.
12
125
93
67
46
12
180
135
90
67
12
275
206
137
103
* Watts to 87-1/2% of nominal voltage.
BATTERY
Sealed Lead-Calcium
ELT125
ELT180
ELT275
Voltage
Shelf
life1
Expected
life1
Maintenance2
Optimum
temperature3
12
6 mos.
5-8 yrs.
none
60°-90°F
1 At 77°C.
2 Periodic system status test recommended.
3 Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
more details.
LAMP SPECIFICATIONS
Spacing Factor:
Indicates the proper
spacing between
lamps to the chosen
illuminance level (fc)
± 20%.
Footcandle Curves:
Show distances in
feet and isocurves in
footcandles.
Lithonia Lighting
Sheet #: ELT-125-180-275
©2000 Acuity Brands Lighting, Inc., Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
INTENDED USE
Ideal for applications where steel housings or metal lamp heads are a requirement.
CONSTRUCTION
18-gauge steel housing finished in instrument tan color.
Hinged faceplate for easy maintenance.
Two 8-watt (ELT16, ELT24, ELT36) or 12-watt (ELT50) incandescent glass
sealed-beam lamps in thermoplastic housings.
Dual-voltage input capability (120 or 277 volts)
BATTERY
Batteries are sealed, maintenance-free, lead-calcium with wattage capacities for 90 minutes of emergency operation. 16-watts (ELT16), 24-watts
(ELT24), 36-watts (ELT36) and 50-watts (ELT50).
Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
ELECTRONICS
AC/LVD reset allows battery connection before AC power is applied and
prevents battery damage from deep discharge.
Current limiting charger maximizes battery life and minimizes energy consumption.
Thermal protection senses circuitry temperature and adjust charge current to prevent overheating and charger failure.
Thermal compensation adjusts charger output to provide optimum charge
voltage relative to ambient temperature.
LISTING
UL listed. Meets UL 924, NFPA 101, NEC and OSHA illumination standards.
WARRANTY
Three-year total customer satisfaction warranty. (For complete details, see
warranty sheet in Product Selection Guide).
ORDERING INFORMATION
Family
ELT16
ELT24
ELT36
ELT50
16W/6V
24W/6V
36W/6V
50W/12V
ELT16, ELT24,
ELT36, ELT50
STANDARD LEAD-CALCIUM BATTERY
OPTIONAL NICKEL-CADMIUM
For shortest lead times, configure product using standard options (shown in bold).
Example: ELT36
Input voltage1
Housing color
Lamp heads
Lamp type
Options
(blank) 120V/277V
(blank) Instrument
tan
W White
(blank) Two heads
RO Less heads
MT Metal lamp
heads
PAR36 sealed-beam
6 Volts
(blank) 8W/6V incandescent
N1806 18W/6V incandescent
H1206 12W/6V halogen
12 Volts
(blank) 12W/12V incandescent
N2512 25W/12V incandescent
H1212 12W/12V halogen
(blank) None
LD Load disconnect
switch
T D Integral time delay3,5
N Nickel-cadmium
battery 2
AM Ammeter 3,4
VM Voltmeter3,4
H 8W halogen lamps6
NOM NOM Certified
NOTES:
1 Other voltages available. Consult factory.
2 N is not available with ELT36.
3 ELT50 uses larger housing when ordered
with these options (see ELT-125-180-275
spec sheet for larger housing dimensions).
4 AM and VM must be ordered together.
5 Available on ELT50 only.
6 H option is a 6W lamp on the ELT24.
Emergency
Industrial Steel Emergency Lighting
Accessories
Order as separate items.
ELA WG2 Small wireguard (16W-50W)
ELA MSTS Mounting shelf
Sheet #: ELT-16-24-36-50
INUE-200
ELT16/ELT24/ELT36/ELT50 Industrial Steel Emergency Lighting
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
Shipping weight:
All dimensions are inches (millimeters).
AC Input
Volts Amps Watts
120
.163
16.6
Type
Output
Watts Output
Volts 1-1/2hr. 2hr. 3hrs.
ELT16
277
.069
16.4
120
.167
20
277
.072
20
120
.172
17.8
277
.075
18.0
120
.287
30
277
.108
30
ELT24
ELT36
ELT50
4hrs.
6
16
12
8
6
6
24
24
16
12
6
36
27
18
13.5
12
50
37
25
18
ELT16
ELT24
ELT36
ELT50
ELT50
- 12.8 lbs. (5.8 kgs.)
- 12.8 lbs. (5.8 kgs.)
- 17.3 lbs. (7.8 kgs.)
- 17.3 lbs. (7.8 kgs.)
- (large housing) 30.5 lbs. (13.8 kgs.)*
* Watts to 87-1/2% of nominal wattage.
BATTERY
Sealed Lead-Calcium
Voltage
ELT16
ELT24
ELT36
ELT50
6
6
6
12
Maintenance2
Shelf
Life1
Expected
Life1
6 mos.
5-8 yrs.
Shelf
life1
Expected
life1
3 yrs.
10 yrs.
Optimum
temperature3
60o-90oF
none
Nickel-Cadmium
ELT16
ELT24
ELT50
Voltage
6
6
12
Maintenance2
none
Optimum
temperature3
32o-100oF
* For ELT50 (large housing)
dimensions, reference spec sheet#:
UE205.
1 At 77°C.
2 Periodic system status test recommended.
3 Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity. Consult factory for
more details.
LAMP SPECIFICATIONS
Spacing Factor:
Indicates the
proper spacing
between lamps to
the chosen
illuminance level
(fc) ± 20%.
Footcandle Curves:
Show distances in
feet and isocurves
in footcandles.
Spacing Factor:
Indicates the proper
spacing between
lamps to the chosen
illuminance level (fc)
± 20%.
Footcandle Curves:
Show distances in
feet and isocurves in
footcandles.
Lithonia Lighting
Sheet #: ELT-16-24-36-50
©2000 Acuity Brands Lighting, Inc, Rev. 12/17/07
Emergency Systems Group
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694 Fax 770-981-8141
www.lithonia.com
Catalog Number
Notes
Type
FEATURES
CONSTRUCTION
18-gauge steel housing finished in instrument tan color.
Hinged faceplate for easy maintenance.
Metal lamp heads with two 12-watt tungsten halogen, glass sealed-beam PAR36
lamps.
Industrial Steel Emergency Lighting
Dual-voltage input capability (120 or 277 volts)
BATTERY
ELT24C/
ELT36C
Maintenance-free lead-calcium battery provides 24 watts (ELT24C) or 36 watts
(ELT36C) rated capacity for two hours.
24-hour battery recharge after 90-minute discharge.
Test switch and dual function ready/charge light (green) permit check of system
operation.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery.
Slip-on battery terminals.
ELECTRONICS
LEAD-CALCIUM BATTERY
Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs.
Yellow AC "on" light.
CODES
UL listed. Meets UL 924, NFPA 101-1988 (current Life Safety Code), NEC and
OSHA illumination standards. ELT24C and ELT36C are approved for use in the
city of Chicago (9717-E).
WARRANTY
Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide).
ORDERING INFORMATION
Example:
ELT24C H LD
Accessories
Family
ELT24C
ELT36C
Emergency
Options
AM
VM
CS
RO
H
LD
Ammeter
Voltmeter
3-foot cordset - 120V only
Less lamp heads
8W halogen lamps
Load disconnect switch
Order as separate items.
ELA WG2
ELA MSTS
Wire guard
Mounting shelf
Sheet#: UE-215
INUE-240
ELT24C/ELT36C Industrial Steel Emergency Lighting
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are inches (millimeters).
Shipping weight: ELT24C - 12.5 lbs. (5.7 kgs.)
ELT36C - 17.0 lbs. (7.7 kgs.)
Type
ELT24C
ELT36C
AC Input
Volts Amps Watts
120
.167
20
277
.072
120
.167
20
277
.072
Output
Watts Output*
Volts 1-1/2hr. 2hr. 3hrs. 4hrs.
6
24
24
16
12
6
36
36
24
18
* Watts to 87-1/2% of nominal wattage.
BATTERY
Sealed Lead-Calcium
ELT24C
Voltage
Shelf
life1
Expected
life1
Maintenance2
Optimum
temperature3
6
6 mos.
5-8 yrs.
none
60o-90oF
1 At 77°C.
2 Periodic system status test recommended.
3 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes.
Higher and lower temperatures affect life and capacity. Consult factory for more details.
LAMP SPECIFICATIONS
Spacing Factor:
Indicates the proper
spacing between
lamps to the chosen
illuminance level (fc)
± 20%.
Footcandle Curves:
Show distances in
feet and isocurves in
footcandles.
Lithonia Lighting
Sheet #: UE-215
©2000 Acuity Brands Lighting, Inc., Rev. 2/12/07
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 770-922-9000
www.lithonia.com