Emergency - Acuity Brands
Transcription
Emergency - Acuity Brands
Emergency Emergency Lighting Units Family FileName Description RevisionDate 680.193 ela-cl ELA-IND-NX ELA-IND-PM-CM-RHB-R3 ela-lv3 ELA-MR24 ELA-MT-WP-Z ELA-OMC-ELA-AFNR ela-osl ELA-RG-SG-RR ELA-RTLP-MS-VS2-WG ELA-RTT-BS ela-sb-oc-eb UE-406 UE-510 UE-610 Exit Discharge Guide Core lights Industrial remotes Indura® pendant and ceiling mounting kits/remote head bracke Remote downlights, MR16 Adjustable remotes Unit Accessories (ELA MT, ELA WP, ELA Z) Outdoor Mini Cylinder and Affinity® Remote Fixture Outdoor Step Lights Gimbals & rectangles Remote test switch, mounting shelf, vandal-resistant shield, Indura remote test transmitter banding strap Remote downlights, PAR36 Remote heads Low-voltage remote downlight relay Voltage Drop Tables 08/15/2003 12/20/2007 12/20/2007 08/03/2006 12/20/2007 12/17/2007 02/18/2008 12/20/2007 12/20/2007 12/17/2007 03/11/2008 12/05/2005 12/20/2007 12/17/2007 03/15/1989 06/15/1997 ELA-ZCD ELA-ZX Z ZX Class II - Division 1 Remote Class I - Division 1 Remote Class I - Division 2 Unit Class I - Division 1 Unit 10/16/2007 10/16/2007 10/16/2007 12/11/2007 IND6-12-24 INDX Indura® 6, 12 or 24V sealed lead-calcium or ni-cad battery, Indura® 6, 12 or 24V sealed lead-calcium or ni-cad battery, 10/30/2007 09/28/2007 ELM6-12 ELM ELM2 Quantum® high capacity unit Quantum® 6V 12W lead-calcium, fixed optics Quantum® 6V 12W lead-calcium, fully adjustable optics 12/17/2007 06/25/2007 06/25/2007 680.211 AFN ELCC ELR2-2P-4 ELRG ELSQ-M VEL Guideline Specification Architectural Emergency Light 6V-12W Lead-calcium 6V-16W and 12V-50W Lead-calcium Dual-voltage input, 8W halogen lamp head 6V-10W and 6V-20W Lead-calcium Concealed Emergency Lighting Unit 08/15/2003 09/28/2007 11/08/2007 12/17/2007 01/02/2008 09/28/2007 09/28/2007 125W/12V, 180W/12V, or 275W/12V lead-calcium Titan® 16W/6V, 24W/6V, 36W/6V, or 50W/12V lead-calcium or ni 6V 24-36W Lead-calcium - Chicago approved 12/17/2007 12/17/2007 02/12/2007 Emergency Lighting Remotes ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA ELA Hazardous Location ELA ZCD ELA ZX Z ZX Indura® Industrial IND INDX Quantum® Series Thermoplastic ELM6-12 ELM-ELM2 ELM-ELM2 Specialty Commercial AFN AFN ELCC ELR ELRG ELSQ VEL Titan® Steel Industrial ELT ELT ELT ELT-125-180-275 ELT-16-24-36-50 UE-215 Exit Discharge Application Guide for Normally-off Fixtures Traditional emergency lighting and exit signs were primarily focused on guiding occupants to the exterior of a building. Today, an additional focus is being placed on getting occupants to an exit safely and down a path of safety once they are out of the building. This guide will help define the exit discharge, reference code requirements for the exit discharge, and identify products that can be applied to meet exit discharge requirements. Either normally-on or normally-off fixtures can provide exit discharge illumination. However, this guide will only cover normally-off remote fixtures. Interior Normal or conditioned space Path of egress ExteriorDamp or wet location Exit discharge Exit Discharge Description The exit discharge is the portion of the means of egress between the building exit and the public way. According to the 2003 Life Safety Code, section 3.3.175, a public way is defined as "A street, alley or other similar parcel of land essentially open to the outside air deeded, dedicated, or otherwise permanently appropriated to the public for public use and having a clear width and height of not less than 30ft (50mm) (120in)." Since the nature of the exit discharge is outdoor applications, standard luminaires may not be suitable. Outdoor applications fall into two categories: damp location or wet location. According to chapter one, article 100, of the 2002 National Electrical Code, damp locations include ". . .partially protected locations under canopies, marquees, roofed open porches, and like locations. . ." Wet location is partially defined as ". . .locations subject to saturation with water or other liquids, such as vehicle washing areas; and in unprotected locations exposed to weather." See page 4 for Code information. Sheet #: 680.193 REF - 160 Remote Fixtures In general, remote fixtures offer advantages such as lower initial cost, lower maintenance costs, and better aesthetics over typical emergency battery units. These advantages are more prevalent in environments that require special ratings such as wet location and NEMA 4X, or in areas where ambient temperatures can diminish battery capacity or life. Both occurances are common with the exit discharge. In many instances, the battery unit can be installed in a normal or conditioned environment with the remote heads located in the areas that require special ratings. The following chart lists normally-off remote fixtures that may be used in damp or wet locations. Please consult the Lithonia Lighting Product Selection Guide for lamp type, voltage, and wattage. Description Lamp Wall Mount Architectural die-cast Xenon x Recessed gimbal PAR36 Halogen incandescent x x ELA LV3 OC Recessed 3” adjustable specular open cone 6V, 12V MR16 halogen x x ELA OC Recessed 6” adjustable specular, open clear 6V, 12V PAR36 Halogen incandescent x x ELA LV3 SB Recessed 3” baffled reflector white, 6V, 12V MR16 Halogen x x ELA SB Recessed 6” baffled reflector white, 6V, 12V PAR36 Halogen incandescent x x ELA LV3 EB Recessed 3” baffled eyeball white, 6V, 12V MR16 Halogen x x ELA EB Recessed 6” baffled eyeball white, 6V, 12V PAR36 Halogen incandescent x x Recessed outdoor step light Die-cast aluminum, 12V Halogen (not MR11 or MR16) Fixture AFN ELA RG ELA OSL ELA Core Light ELA OMC Recessed round, outdoor core light, die-cast aluminum, 6V, 12V Surface-mount outdoor mini cylinder die-cast aluminum 6V, 12V Ceiling Mount Wet Damp x x x x x x x x x x Cold Weather x -40oC to 60oC MR16 Halogen MR11 Halogen x x x x ELA QR* Surface-mount Q-Bic remote 4” square polycarbonate ELA WP Surface-mount weatherproof aluminum, 12V ELA NX* Surface-mount wet location sealed glass gray, white, black 6V, 12V PAR36 Halogen incandescent x ELA Z Surface-mount Class 1, Div. 2 haz. location, sealed glass, gray 6V, 12V PAR36 Halogen incandescent x Halogen incandescent 35W, PAR46 incandescent x x x x x x x x x x * These remote fixtures are offered in single and twin head versions. Page 2 Power Sources Once the classification of an environment is determined and the remote fixtures have been chosen, the next step is to determine which power sources will operate the remote fixtures from a normal or controlled environment. If a facility utilizes unit equipment for its emergency lighting, the option of running the exit discharge remote(s) off of those units should be considered. By utilizing the chart below, select which unit(s) will work best for the application. Application Commercial / Light Industrial Commercial / Light Industrial Commercial / Light Industrial Industrial / Commercial Industrial / Commercial Industrial / Commercial Unit 6ELM2P ELM4 ELM10 IND6 IND12 IND24 Volts 6 12 12 6 12 24 Total Capacity 24W 50W 125W 16 -100W 36 - 450W 100 - 450W TM 6ELM2P IND6, IND12, IND24 If the facility is not utilizing unit equipment for its emergency lighting, the exit discharge remote(s) can be powered by special exit signs that are placed above any door leading to the exit discharge. The exit/unit combination, LHQM, provides 6 to 21.6 watts of remote capacity depending on the unit and option(s) selected (see chart below). The ELA LEHO is a canopy accessory that provides 11 watts of remote capacity after it has been field-installed on a Signature® LED emergency exit sign. Application Commercial / Light Industrial Commercial / Light Industrial Commercial / Light Industrial Commercial / Light Industrial ELA LEHO Unit LHQM with HO LHQM with R0 LHQM with HO & R0 ELA LEHO Volts 6 6 6 6 Remote Capacity (Watts) 10.8 10.8 21.6 11 LHQM Page 3 Codes Life Safety Code (NFPA 101) Section 3.3.136 Means of Egress: A continuous and unobstructed way of travel from any point in a building or structure to a public way consisting of three separate and distinct parts: (1) the exit access, (2) the exit, and (3) the exit discharge. Section 3.3.136.1 Accessible Means of Egress Section 7.9 Emergency Lighting: 7.9.1.2 “. . .exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way.” Section 7.9.2 Performance of System: 7.9.2.1 “Emergency illumination shall be provided for not less than 1-½ hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less than 0.06 ft-candle (6.5 lux) at the end of the 1-½ hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded.” Since exit discharge is one of the three components defined as the "means of egress" per 3.3.121 of the Life Safety Code and since 7.9.1.1 also includes exit discharge, many authorities having jurisdiction have concluded that the lighting levels of 7.9.2.1 apply in full. Note: Variations may exist depending upon the interpretation of codes in your area. Reprinted with permission from NFPA 101® Life Safety Code®, 2003 Edition. National Fire Protection Association, Quincy, Massachusetts 02269. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. Lithonia Lighting © 2002 Acuity Lighting Group, Inc., 09/03 Form No. 680.193 680.193.p65 Acuity Lighting Group, Inc. Emergency Lighting Systems One Lithonia Way, Decatur, GA 30035 Phone 800 334-8694, Fax 770 981-8141 In Canada: 1100 50th Ave., Lachine, Quebec H8T 2V3 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Small, attractive, round, outdoor remote core light. Ideal for use outside doorways to meet exit discharge requirements of the Life Safety Code. To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. Unit Accessories ELA CL CONSTRUCTION Copper-free cast-aluminum face plate with stainless steel hardware. Standard with satin bronze finish. Weather-tight cable connector with 5', 12-gauge, 2wire, low-voltage cable. Core Light INSTALLATION Installs with counter sunk 3/16" diameter screws (not provided). LAMP Variety of MR16 lamp wattages and voltages available. ORDERING INFORMATION ELA Family ELA Emergency Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA CL H0506 CL Housing color (blank) Bronze Lamp type Fixture CL Round outdoor step light H0506 H1006 H2006 H1012 H2012 5W/6V MR16 lamp 10W/6V MR16 lamp 20W/6V MR16 lamp 10W/12V MR16 lamp 20W/12V MR16 lamp Sheet #: ELA CL RAUE-130 ELA CL Core Light DIMENSIONS All dimensions are in inches (centimeters). 4-1/2" (11.4) 5" dia (12.7) 1-3/8" (3.4) Cast aluminum face 1 3-1/2" O.C. (8.8) 68" angle = A 90" angle = B Weather - light cable connector with 5'0", 12 Ga., 2 wire low voltage, cable. Two countersunk, 3/16" dia. holes (hardware by others) Rectilinear lens provides wide lateral distribution with prisms in vertical position and long narrow distribution in horizontal Provide 2-1/2" dia. Hole for slip fit. Lithonia Lighting Sheet #: ELA CL © 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. Matches Indura® family appearance. Unit Accessories ELA IND CONSTRUCTION Fully adjustable lamp heads meet all aiming requirements. Lamp head and mounting plate constructed of heavyweight polycarbonate. Removable bezel allows tool-less lamp replacement and easy maintenance. INSTALLATION Remote Fixture Universal mounting base for use with single- or twin-head applications. Base may be installed horizontally for single lamps or vertically for twin-head applications. Attaches to single gang J-box with a 3-9/32" hole spacing or comparable adaptations. LAMPS Krypton, incandescent and halogen composite lamps available in 6, 12 and 24 volts; 6 to 20 watts. Unique, field-adjustable beam pattern for composite lamps by rotating bezel. Incandescent and halogen sealed-beam lamps available on 6 and 12 volts; 6 to 50 watts. Refer to specification sheet UE-615, UE-625, UE-626, UE-627 or the Indura Application Guide (form no. 680.185) for spacing and performance comparisons between lamps. DIMENSIONS Mounting base: 5-1/8"W (128mm) x 4-11/16"H (120mm) x 4-15/16"D (125mm) Single: 5-1/8"W (128mm) x 5-7/8"H (149mm) x 5-7/16"D (138mm) Twin: 7-1/8"W (181mm) x 5-1/8"W (128mm) x 5-7/16"D (138mm) LISTING Listed in accordance with UL 1598. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA K0906 ELA Remote head ELA IND Color (blank) Gray / blue housing W Ivory white Number of heads (blank) Single T Twin Family IND Indura Lamp type 6 Volts: PAR36 Composite K0906 9W/6V krypton H1206 12W/6V halogen H2006 20W/6V halogen 12 Volts: PAR36 Composite K0912 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen PAR36 Sealed-beam H3512S 35W/12V halogen H5012S 50W/12V halogen 24 Volts: PAR36 Composite N1824 18W/24V incandescent H2024 20W/24V halogen PAR36 Sealed-beam N5024S 50W/24V incandescent Emergency Sheet #: ELA-IND-NX RAUE-180 Catalog Number FEATURES & SPECIFICATIONS Notes INTENDED USE Type To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. Ideal for damp and wet location areas requiring remote lighting. Unit Accessories CONSTRUCTION ELA NX Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Constructed of fiberglass-reinforced Lexan. Fully gasketed mounting plate. Removable bezel and sealed, phosphor-bronze slip-on lamp terminals. Sealed Remote Fixture INSTALLATION Universal mounting plate for use with single or twin-head applications. Attaches to single gang J-box with a 3-9/32" hole spacing or comparable adaptations. LAMP Glass sealed-beam PAR36 lamp(s). DIMENSIONS Mounting base: 3-1/8"W (79mm) x 5"H (127mm) Single: 7-3/4"H (197mm) x 4-3/4"W (121mm) x 4-9/16"D (116mm) Twin: 6-5/8" (168mm) x 13" (330mm) x 3-11/16" (93mm) LISTING Listed for wet location in accordance with UL1598. ORDERING INFORMATION Example: ELA NX Family ELA ELA NX H1212 Housing color (blank) Gray W White B Black Number of heads (blank) Single T Twin Fixture NX Sealed and gasketed PAR36 Lamp type (PAR36 sealed-beam) Incandescent N0806 8W/6V N1206 12W/6V N1212 12W/12V N1812 18W/12V N2512 25W/12V N3512 35W/12V Halogen H0606 6W/6V H0806 H1206 H0812 8W/6V 12W/6V 8W/12V H1212 12W/12V H3512 H5012 35W/12V 50W/12V Lithonia Lighting Sheet #: ELA-IND-NX © 2004 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS Support bracket for pendant mounting the Indura® small housing. Not available for large housing units. Unit Accessories FEATURES 16 ga. galvanized sheet steel. 3.8" x 4" x 1.45" Includes one pendant mount bracket and two 1/2" slotted hex head screws. ELA IND PM Conduit and canopy are not provided. Pendant Mount Kit ORDERING INFORMATION Catalog Number ELA IND PM Description Pendant mount kit for Indura small housing: IND618, IND654, IND1236, IND1254, IND6100. FEATURES & SPECIFICATIONS Battery support brackets for use when ceiling mounting the Indura small housing unit. Not available for large housing units. FEATURES Unit Accessories ELA IND CM 20 ga. galvanized sheet steel Includes one ceiling-mount bracket and one Phillips head screw. Ceiling Mount Kit ORDERING INFORMATION UL listed products Catalog Number ELA IND CM1 ELA IND CM2 ELA IND CM3 ELA INDX CMZ Emergency Description Ceiling mount kit for IND618 Ceiling mount kit for IND654, IND1236, IND1254, INDX654, INDX1236 and INDX1254 Ceiling mount kit for IND6100 Ceiling mount kit for INDX654, INDX1236, INDX1254 Sheet #: ELA-IND-PM-CM-RHB RAUE-220 Catalog Number FEATURES & SPECIFICATIONS Bracket for surface mounted single-gang j-boxes with 3-9/32" hole spacings for Indura remote heads. Notes Type FEATURES Seals opening between surface mount box and Indura mounting plate. Dimensions fit footprint of remote Indura head mounting plate. Unit Accessories ELA IND RHB Indura® Remote Head Bracket ORDERING INFORMATION Catalog Number ELA IND RHB Description Remote head bracket to use with surface-mounted jboxes. FEATURES & SPECIFICATIONS Prepack provides template and hardware to field install third head on Indura unit equipment. FEATURES Includes template and instructions to help with the drilling of holes for the third lamp on the small or large Indura housing. Includes necessary hardware to field install third head. Tools needed: 9/64" (.140") dull bit; 1/2" (.500") dull bit Phillips screwdriver. Unit Accessories ELA IND R3 Indura® Third Head Mounting Kit ORDERING INFORMATION Catalog Number Description ELA IND R3 Prepack kit to field install third head on Indura unit. Lithonia Lighting Sheet #: ELA-IND-PM-CM-RHB-R3 © 2000 Acuity Lighting Group, Inc., Rev. 8/06 Emergency Lighting Systems One Lithonia Way, Lithonia, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Attractive, unique emergency downlight remote utilizing MR16 lamps. Innovative and advanced, the MR16 halogen luminaire provides excellent lighting control. Available in a range of trim styles. Frame-in module and trim supplied. To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. Unit Accessories ELA LV3 CONSTRUCTION Tempered glass safety lens standard. Drawn, one-piece seamless 5-1/4" aluminum housing. Lightweight, rust resistant. Factory-installed, expandable, captive bar hangers with double-barbed, 3/4" recessed nailers. Bar hangers adapt to T-bar with no additional accessories. Crimp locking on J-box side plus locking clip on rail side allow off-center mounting anywhere between 24" rigid joists or T-bar. Length of 25-1/4" maximum, 13-1/ 4" minimum or cut to fit a minimum space of 7-1/2". 3" MR16 Downlight Series Galvanized steel junction box with semi-captive snap-on covers and ground wire. Built-in Romex clamps secure Romex cable inside J-box. Easy to remove 1/2" and 3/4" pryouts provided for straight-through conduit runs. Capacity: 4 (2 in, 2 out) No. 12 AWG conductors, rated for 90oC. Approved for all wiring types. Adjustment slots in can accommodate ceiling thicknesses up to 2". Precisionwound stepdown transformer with class H insulation. For dimming control, use only dimmers specifically designed for use with transformers. Two-pin porcelain socket. 16 15 TRIM Three trim styles available: Baffle Reflector, Adjustable Specular Open and Baffle Eyeball. INSTALLATION Retaining clips hold finishing trim secure and snug to ceiling. Baffled Reflector ORDERING INFORMATION ELA LV3 Family Series ELA LV3 Baffled Eyeball Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA LV3 SB H1006 Trim SB OC EB Emergency Open Clear Specular Baffled reflector white Adjustable spectular open-clear Baffled eyeball-white Lamp type H0506 H1006 H2006 H1012 H2012 H3512 H5012 5W/6V MR16 lamp 10W/6V MR16 lamp 20W/6V MR16 lamp 10W/12V MR16 lamp 20W/12V MR16 lamp 35W/12V MR16 lamp 50W/12V MR16 lamp Sheet #: ELA LV3 RAUE - 160 ELA LV3 3" MR16 Downlight Series DIMENSIONS All dimensions are inches (centimeters). 5" (12.7) Baffled Reflector Adjustable Open Clear Specular 3-5/8" (9.2) 5" (12.7) 3-5/8" (9.2) 5" (12.7) Baffled Eyeball 1-3/4" (4.4) 3" (7.6) 5" (12.7) 4" (10.2) 11-3/4" (29.8) 13-1/2" (34.3) 6" (15.2) 4" (10.2) Lithonia Lighting Sheet #: ELA LV3 © 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Notes Type SPECIFICATIONS INTENDED USE To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. MR24 fixture matches the appearance of the Quantum® family units. CONSTRUCTION Unit Accessories ELA MR24 Single or twin heads available. Fully adjustable lamp heads to meet all aiming requirements. Strong, compact and corrosion-resistant with a UL94V-O flame rating. Constructed of UV-stabilized thermoplastic that resists discoloration by natural or artificial sunlight. Lamp housing snaps off for easy lamp replacement. US Patent No. D484,272. INSTALLATION Remote Fixture Adjustable lamp head Universal mounting base for use with single- or twin-head applications. Standard mounting: 6.78"W x 4.58"H. Mounts to a single-gang switch box. LAMP Complete range of lamp wattages and voltages available. DIMENSIONS Single and twin: 8"W x 4.58"H. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA MR24 ELA Family ELA MR24 Housing color (blank) White B Black Emergency Number of heads (blank) Single T Twin Fixture Lamp type MR24 Multi-faceted reflector and adjustable lamp head K0606 6W/6V krypton lamps K0906 9W/6V krypton lamps K0912 9W/12V krypton lamps H1206 H1212 H2006 H2012 12W/6V halogen lamps 12W/12V halogen lamps 20W/6V halogen lamps 20W/12V halogen lamps Sheet #: ELA-MR24 RAUE-105 ELA MR24 Quantum® Thermoplastic Remote Fixture Lithonia Lighting Sheet #: ELA-MR24 © 2002 Acuity Brands Lighting, Inc., Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS INTENDED USE Unit Accessories To be powered by 6, 12 or 24 volt battery equipment or 120 volt power source as part of an emergency lighting system providing light for the path of egress. MT fixture matches industrial unit. ELA MT CONSTRUCTION Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Brushed aluminum lamp housing and steel mounting plate. Removable steel ring provides easy lamp replacement. Remote Fixture INSTALLATION Single mounting plate: 2-3/4"W x 4-1/2"H, mounts to single-gang switch box. Twin mounting plate: 8-1/4"W x 4-1/2"H, mounts to four-gang j-box. LAMP Glass sealed-beam PAR36 lamp(s). DIMENSIONS Single: 4-5/8"W x 4-5/8"H. Twin: 11"W x 4-5/8"H. LISTING Listed in accordance with UL 1598 and CSA C22.2 No. 250. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA MT N0806 MT ELA Family Housing color ELA (blank) Brushed aluminum Number of heads (blank) Single T Twin Lamp type (PAR36 sealed-beam) Fixture MT Metal PAR36 sealed-beam SPECIFICATIONS N0806 N1206 N1806 N1212 N1812 N2512 N15120 8W/6V incandescent 12W/6V incandescent 18W/6V incandescent 12W/12V incandescent 18W/12V incandescent 25W/12V incandescent 15W/120V incandescent, composite N30120 30W/120V incandescent, composite N50120 50W/120V incandescent, composite H0606 H0806 H1206 H0812 H1212 H3512 H5012 6W/6V halogen 8W/6V halogen 12W/6V halogen 8W/12V halogen 12W/12V halogen 37.5W/12V halogen 50W/12V halogen Unit Accessories INTENDED USE Ideal for remote applications where a weather proof fixture is necessary. CONSTRUCTION Aluminum housing and swivel. Clear, heat-resistant glass globe. 35W PAR46 sealed-beam incandescent lamp. ELA WP Waterproof Fixture DIMENSIONS Single: 6-3/8"W x 8-1/2"H. ORDERING INFORMATION Example: ELA WP Catalog Number Volts Watts Lamp No. ELA WP 12 35 4413 Emergency Sheet#:ELA-MT-WP-Z RAUE-190 Catalog Number SPECIFICATIONS INTENDED USE To be powered by 6 or 12 volt battery equipment as part of an emergency lighting system providing light for the path of egress in Class 1, Division II environment. CONSTRUCTION Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Lamp head constructed of lightweight, gray, thermoplastic and fully gasketed. Removable bezel and slip-on lamp terminals simplify maintenance and lamp replacement. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. INSTALLATION Mounting plate: 5"H x 3-1/8"W. Mounts to single-gang switch box. LAMP Glass sealed-beam PAR36 lamp(s). DIMENSIONS Notes Type Unit Accessories ELA Z Class I, Div. 2 Remote Fixture Single: 5.1" W x 6.25" H. ORDERING INFORMATION ELA Z Family Fixture ELA Z Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA Z N0806 Number of heads Class 1, Div II remote head (blank) T Single Twin Lamp type (PAR36 sealed-beam) N0606 N0806 N1806 N1212 N1812 N2512 H0806 H1206 H0812 H1212 6W/6V incandescent 8W/6V incandescent 18W/6V incandescent 12W/12V incandescent 18W/12V incandescent 25W/12V incandescent 8W/6V halogen 12W/6V halogen 8W/12V halogen 12W/12V halogen Lithonia Lighting Sheet#:ELA-MT-WP-Z © 2000 Acuity Brands Lighting Inc., Rev. 2/18/08 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS Unit Accessories INTENDED USE Small, attractive remote head utilizing MR11 lamps. Ideal for use outside of doorways to meet exit discharge requirement of the Life Safety Code. To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. ELA OMC CONSTRUCTION Die-cast aluminum body with cast bronze knuckle. Cylinder standard with black finish. Tempered glass lens. INSTALLATION 1/2" NPT adjustable knuckle. Single mounting plate - round die-cast 4-0 box cover. OUTDOOR MINI CYLINDER Twin mounting plate dimensions (rectangle): 4-1/2"L x 2-7/8"W. LAMP Variety of MR11 lamp wattages and voltages available. LISTING UL Listed. IP rating: 65. UL Listed for wet locations. DIMENSIONS All dimensions are inches (centimeters). Dimensions shown are for single mounting plates. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA OMC H0506 ELA Family ELA Emergency OMC Housing color (blank) Black DNA Natural aluminim DDB Dark bronze Fixture (blank) Single T Twin Fixture OMC Outdoor mini-cylinder Lamp type H0506 H1006 H2006 H1012 H2012 5W/6V MR11 lamp 10W/6V MR11 lamp 20W/6V MR11 lamp 10W/12V MR11 lamp 20W/12V MR11 lamp Sheet #: ELA-OMC-ELA-AFNR RAUE-140 Catalog Number Notes Type FEATURES & SPECIFICATIONS ® INTENDED USE For applications requiring low-profile, attractive emergency lighting. To be powered by 6V battery equipment as part of an emergency lighting system, providing light for the path of egress. Ideal for damp and wet location areas requiring remote lighting. CONSTRUCTION Compact, low-profile, architectural design with die-cast aluminum housing that has a contemporary brushed nickel-plated finish. Other available finishes are texturized polyester powder coat paint in white, black and dark bronze. All finishes can be painted in the field to match the wall color of choice. U.S. Patent No. D468,046. Two 6-watt, 6-volt, wedge-base xenon lamps offer 55 percent more light output than standard incandescent lamps. Meets requirements for NEC 700.16. Patent-pending reflector/refractor design features superior vac-metalized, diecasted reflectors; and multi-faceted, highly transmissive refractor that significantly improve photometrics. Unit Accessory ELA AFNR REMOTE FIXTURE Universal J-box mounting pattern. Rigid conduit entry provision on top of the unit. LISTING UL Listed for wet locations in accordance with UL 924. Cold weather listed -18°C to 50°C. ORDERING INFORMATION ELA AFNR Family Fixture ELA For shortest lead times, configure product using standard options (shown in bold). Example: ELA AFNR DB Finish AFNR Remote Affinity fixture W White B Black BN Brushed nickel DB Dark bronze NOTE: Refer to AFN specification sheet for photometric and dimensional data. Lithonia Lighting Sheet #: ELA-OMC-ELA-AFNR ©2007 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Systems Group One Lithonia Way, Conyers, Ga 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Small, attractive rectangular outdoor remote step light. Ideal for use outside doorways to meet exit discharge requirements of the Life Safety Code. To be powered by 6- or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. CONSTRUCTION Unit Accessories ELA OSL Outdoor Step Light Cast bronze fixture with stainless steel fasteners. Diffused tempered glass lens. Completely weatherproof with neoprene gasket. INSTALLATION One 3/4"NPT tapper entrance hub at each end standard. LAMP Halogen bi-pin lamp - not included LISTING UL Listed. UL Listed for wet locations. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA OSL ELA Family ELA Emergency OSL Housing color (blank) Bronze Fixture OSL Outdoor step light Sheet #: ELA OSL RAUE - 150 ELA OSL Outdoor Step Light DIMENSIONS All dimensions are in inches (centimeters). 10-1/2" (26.7) 5-3/8" (13.7) 3-1/4" (8.3) 1-5/8" (4.1) 3-1/4" (8.3) 3/4" (1.9) Lithonia Lighting Sheet #: ELA OSL © 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS CONSTRUCTION Aluminum with matte white finish on exposed surfaces. Unit Accessories ELA RG Mounts recessed into 5-3/4" diameter opening in wall or ceiling. Gimbal suspension provides aiming through 70o tilt and 359o rotation. 4-inch standard box and "T" retainer clips included. MOUNTING Mounts recessed into 5-3/4" diameter opening in wall or ceiling. LAMP PAR36 sealed-beam lamp included. Recessed Gimbal Front-relamping: remove two screws in trim to access lamp housing. DIMENSIONS Single: 8-1/4"W x 5-1/4"D. ORDERING INFORMATION RG ELA Fixture Family ELA Lead times will vary depending on options selcted. Consult with your sales representative. Example: ELA RG N0806 RG Recessed gimbal Lamp type N0806 8W/6V incandescent PAR36 sealed-beam N1212 12W/12V incandescent PAR36 sealed-beam N1812 18W/12V incandescent PAR36 sealed-beam N2512 25W/12V incandescent PAR36 sealed-beam H0806 8W/6V halogen PAR36 sealed-beam H0812 8W/12V halogen PAR36 sealed-beam H1212 12W/12V halogen PAR36 sealed-beam SPECIFICATIONS Unit Accessories CONSTRUCTION ELA SG Aluminum with matte white finish on exposed surfaces. Gimbal suspension provides aiming through 70o tilt and 359o rotation. 4-inch standard box included. MOUNTING Mounts on wall or ceiling. Surface Gimbal LAMP PAR36 sealed-beam lamp included. Front relamping: remove two screws in trim to access lamp housing. DIMENSIONS Single: 7-7/8" W x 4" D. ORDERING INFORMATION ELA SG Fixture Family ELA Emergency Lead times will vary depending on options selcted. Consult with your sales representative. Example: ELA SG N0806 SG Surface gimbal Lamp type N0806 8W/6V incandescent PAR36 sealed-beam N1212 12W/12V incandescent PAR36 sealed-beam N1812 18W/12V incandescent PAR36 sealed-beam N2512 25W/12V incandescent PAR36 sealed-beam H0806 8W/6V halogen PAR36 sealed-beam H0812 8W/12V halogen PAR36 sealed-beam H1212 12W/12V halogen PAR36 sealed-beam Sheet#: ELA-RG-SG-RR RAUE - 120 Catalog Number SPECIFICATIONS CONSTRUCTION Notes Type Housing constructed of matte black steel with removable white front bezel. Dropped frosted glass lens. Double-contact bayonet base socket. Accepts S8 or S11 lamp, 25 watts maximum (lamp not included). MOUNTING Mounts recessed into opening 6-1/2" x 3-1/4", 2-3/4" deep in wall or ceiling. LAMP S8 or S11 DC bayonet base lamp up to 25W (not included). DIMENSIONS Single: 8-3/16"W x 4-1/2"H. Unit Accessories ELA RR Recessed Rectangle ORDERING INFORMATION ELA RR Family Fixture ELA RR Lead times will vary depending on options selcted. Consult with your sales representative. Example: ELA RR Recessed rectangle Lithonia Lighting Sheet #: ELA-RG-SG-RR © 1997 Acuity Brands Lighting, Inc., Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS Provides remote testing capability for all Lithonia unit equipment and exit signs. CONSTRUCTION Remote test switch plate includes white rocker-type test switch. White plate matches most ceiling tiles. Remote test switch plate installs onto a standard single-gang switch box with screws (provided). Mounts in ceiling or wall near emergency lighting unit. OPERATION Unit Accessories ELA RTLP REMOTE TEST SWITCH Compatible with all Lithonia emergency lighting units and exits. Not compatible with emergency downlights and Power Sentry inverters. Provides the ability to test the emergency operation of the unit from a remote location. Recommended mounting no more than 25' from lighting unit. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELARTLP ELARTLP Family ELARTLP Remote test switch for unit device Unit Accessories SPECIFICATIONS ® For mounting ELM4, ELM10, ELU Series or Titan Series unit equipment on wall or pole. CONSTRUCTION Heavy-gauge steel construction with instrument tan finish. ELA MS MOUNTING Shelf mounts onto wall or pole with screws (not provided). MOUNTING SHELF Unit attaches directly onto shelf with screws (not provided). ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA MS4/8 Family ELA MS2 ELA MS4/8 ELA MST ELA MSTS 20-gauge 16-gauge 18-gauge 18-gauge steel steel steel steel shelf for ELU2, ELU2P* shelf for ELU4, ELU8, ELM4, ELM10* shelf for Titan ELT180, ELT250, ELT275 shelf for Titan ELT16, ELT24, ELT24C, ELT36, ELT36C, ELT50 *To order white, add W to the catalog number. Example: ELA W MS4/8 Emergency Sheet#: ELA-RTLP-MS-VS2-WG RAUE - 200 Catalog Number SPECIFICATIONS To provide protection from vandalism for the ELM and ELM2 (ELA VS), and large QUANTUM® products (ELA VS2). Notes Type CONSTRUCTION Unit Accessories 1/8" thick (ELA VS2) or 3/16" thick (ELA VS), high-impact, transparent polycarbonate. Fits all QUANTUM ELM and ELM2 (ELA VS), and larger QUANTUM units (ELA VS2). Contemporary rounded-corner design. 10" H x 22" W x 9-3/4" D (ELA VS2); 8-1/2" H x 15" W x 4-3/4" D (ELA VS). ELA RTLP remote test switch recommended; mounts up to 25' from unit. MOUNTING Twelve 3/6" diameter pre-drilled mounting holes. ELA VS2 ELA VS ELA VS2 Vandal-resistant hardware not provided. VANDAL-RESISTANT SHIELD ELA VS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA VS Family ELA VS ELA VS2 Vandal shield for ELM and ELM2 unit equipment Vandal shield for large Quantum products (ELM618, ELM627, ELM654, ELM1254 and ELM1272)1 NOTES: 1 ELA VS2 can be used with discontinued 6ELM2P, ELM4 and ELM10. SPECIFICATIONS Unit Accessories Provides protection from vandalism for units and remote heads. ELA WG CONSTRUCTION 1/4" steel rod construction on front and sides with zinc plate finish — ELA WG4/8, ELA WGRH, ELA WGLT, ELA WG2. 3/16" steel rod construction on front sides, top and bottom with powdercoated metallic gray finish — ELA WG2M, ELA WGHQM, ELA WGST. WIREGUARD MOUNTING Four 7/16" diameter mounting holes — ELA WG4/8, ELA WGRH, ELA WGLT, ELA WG2. Four 3/8" diameter mounting holes — ELA WG2M, ELA WGHQM, ELA WGST. COMPATIBILITY AND ORDERING INFORMATION U.S. Units ELA WGHQM ELA WGLG ELA WGLT ELA WGRH ELA WGST ELA WG2 ELA WG2M ELA WG4/8 ■ IND (150-450 Watts) IND 100W PREM & ULT ELM, ELT 16, 24, 36, 50, ELSQ LHQM ELM2, ELM4, ELM10, ELU8, 6ELM2, 6ELM2P IND (16-100 Watts) Not IND 100W PREM & ULT ELT 50 (w/option), 125, 180, 250, 275 Twin remote heads Single remote heads Catalog Number ELT 502 (w/options), 1252, 180 2, 2502, 2752, INDX UL Listed Products ■ ■ ■ ■ ■ ■ ■ ■ Dimensions 28W x 15H x 8D 21W x 20H x 18D 2215/16W x 243/8H x 123/8D 1115/16W x 123/8H x 93/8D 15W x 15H x 6D 151/8W x 143/8H x 85/8D 201/4W x 15H x 10D 221/8W x 2215/16H x 10D Lithonia Lighting Sheet #: ELA-RTLP-MS-VS2-WG ©2000 Acuity Brands Lighting, Inc., Rev. 3/11/08 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS Hand-held InduraTM remote test transmitter used to initiate a 30second test for emergency lighting equipment that has been ordered with the remote test receiver (RT option). CONSTRUCTION • Constructed of lightweight polycarbonate. • 3" long, 1.75" wide, .775" deep. OPERATION • Pressing the remote transmitter button activates a 30-second test from up to 35 feet away on each unit equipped with the remote test receiver (RT option). • Utilizes radio frequency technology, which minimizes interference of obstructions that can sometimes be experienced with infrared technology. • Eliminates crucial time spent climbing ladders or riding lifts. • Ideal for high mounting heights or applications where accessibility to fixture is limited, making performance of a monthly 30-second test required by the Life Safety Code labor intensive. • A minimum of one per job location is required for units ordered with the remote test receiver (RT option) • FCC compliant. BATTERY Unit Accessories ELA RTT Remote Test Transmitter • Utilizes A23 alkaline 12-volt battery with an expected 60 hours of service at 70oF. ORDERING INFORMATION Catalog Number Description ELA RTT Remote test transmitter Emergency Sheet # ELA-RTT-BS RAUE - 210 Catalog Number Notes Type SPECIFICATIONS Mounting accessory banding strap to clamp InduraTM mounting bracket to poles, columns or I-beams. Unit Accessories CONSTRUCTION • Contains one 1/2" wide, 8-1/2' long, 100% stainless steel band. • Includes three fasteners and one extender to make up a total of three worm-drive clamps. MOUNTING • To determine lengths to cut, multiply diameter in inches by p (3.1416), minus 4.5" for the adjustable fastener end, or determine circumference by measurement, minus 4.5" for the adjustable fastener end. ELA BS Banding Strap ORDERING INFORMATION Catalog Number Description ELA BS Banding strap 1/2" wide stainless steel banding 1/2" wide stainless steel fastener and housing assemblies 5/16" stainless steel attached hex-head screw Lithonia Lighting Acuity Lighting Group, Inc. Emergency Lighting Systems One Lithonia Way, Bldg. 3 Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Sheet #: ELA-RTT-BS ela-rtt-bs.pmd © 2000 Acuity Lighting Group, Rev. 12/05 Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Attractively styled, unique emergency downlight remote. Available in a range of trim styles and lamps. Frame-in module and trim supplied. To be powered by 6or 12-volt battery equipment as part of an emergency lighting system providing light for the path of egress. CONSTRUCTION Sturdy steel housing with plaster frame for plaster or tile construction. 27" expandable bar hangers with nailer tabs. Locking screw for off-center mounting between joist or T-bars. Aluminum snap-cap houses quick connector for easy connection to trim assembly. Unit Accessories ELA SB, ELA OC, ELA EB TRIM Three trim styles available: Clear Alzak* Open Cone, Black Stepped Baffle and Black Baffle Eyeball. Internal yoke assembly permits 358o horizontal adjustment and 35o vertical tilt. One-piece reflector/trim eliminates light leaks. Sealed-beam lamp available in 6- or 12-volt incandescent or halogen. 6" Downlight Series * Alzak is a registered trademark of Alcoa. Stepped Baffle ORDERING INFORMATION Clear Alzak Baffled Eyeball Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA OC N0806 ELA Trim style Family ELA OC SB EB ® Clear Alzak open cone Black stepped baffle Black baffleeyeball Lamp type N0806 N1212 H0806 H1212 Emergency Incandescent 8W/6V PAR36 lamp Incandescent 12W/12V PAR36 lamp Halogen 8W/6V PAR36 lamp Halogen 12W/12V PAR36 lamp Sheet #: ELA SB OC EB RAUE - 170 ELA SB, ELA OC, ELA EB 6" Downlight Series DIMENSIONS All dimensions are in inches (centimeters). Stepped Baffle 9-3/8" (23.8) Baffled Eyeball Clear Alzak 5" (12.7) 9-3/8" (23.8) 6" (15.2) 6" (15.2) 7-5/8" (19.3) 7-5/8" (19.3) 4-1/4" (10.7) 6-3/8" (16.1) 7-5/8" (19.3) Lithonia Lighting Sheet #: ELA SB OC EB © 2002 Acuity Brands Lighting, Inc., Rev. 12/20/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Notes Type FEATURES & SPECIFICATIONS INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. CDS fixture matches the appearance of the Quantum® family units. CONSTRUCTION — Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Constructed of engineering-grade thermoplastic. Lamp housing snaps off for easy lamp replacement. Unit Accessories ELA CDS INSTALLATION — Universal mounting plate for use with single or twin-head applications. Standard mounting plate: 3-1/8" W x 5" H. Mounts to a singlegang switch box. LAMP — Complete range of lamp wattages and voltages available. DIMENSIONS — Single: 3-7/8"W x 4-1/4"H. Twin: 10-5/8"W x 4-1/4"H. Remote Fixture LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA CDS N0806 ELA CDS Family Housing color ELA (blank) Ivory white Number of heads Lamp type (composite lamps) Fixture CDS Compact designer square (blank) Single T Twin N0606 6W/6V incandescent N0806 8W/6V incandescent N0912 9W/12V incandescent N1212 12W/12V incandescent Options H0606 6W/6V halogen H0806 8W/6V halogen (blank) Standard mounting plate H0812 8W/12V halogen H1212 12W/12V halogen Unit Accessories FEATURES & SPECIFICATIONS INTENDED USE — To be powered by 6, 12 or 24 volt battery equipment as part of an emergency lighting system providing light for the path of egress. SSB fixture matches the appearance of the Quantum® family units. CONSTRUCTION — Single or twin heads available. Fully adjustable lamp heads meet all aiming requirements. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Constructed of engineering-grade thermoplastic. Lamp housing snaps off for easy lamp replacement. INSTALLATION — Universal mounting plate for use with single or twin-head applications. Mounting plate: 3-1/8" W x 5" D. Mounts to a single-gang switch box. ELA SSB Remote Fixture LAMP — Glass sealed-beam PAR36 lamp(s). DIMENSIONS — Single: 4-3/4" W x 5" D. Twin: 10-1/2"W x 5"H. LISTING — Listed in accordance with UL 1598 and CSA C22.2 No.250. ORDERING INFORMATION Lead times will vary depending on options selcted. Consult with your sales representative. Example: ELA SSB N0806 SSB ELA Family Housing color ELA (blank) Ivory white TN Desert tan Emergency Number of heads (blank) Single T Twin Fixture SSB Square PAR36 sealed-beam Lamp type (PAR36 sealed-beam) N0806 N1206 N1212 N1812 N2512 N3512 8W/6V incandescent 12W/6V incandescent 12W/12V incandescent 18W/12V incandescent 25W/12V incandescent 35W/12V incandescent H0606 H0806 H1206 H0812 H1212 H3512 Sheet #: UE-406 6W/6V halogen 8W/6V halogen 12W/6V halogen 8W/12V halogen 12W/12V halogen 35W/12V halogen RAUE-100 Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE — To be powered by 6 or 12 volt battery equipment as part of an emergency lighting system providing light for the path of egress. This remote fixture matches the ELU family appearance. CONSTRUCTION — Single or twin heads available. Unit Accessories ELA Fully adjustable lamp heads meet all aiming requirements. Lamp head and mounting plate constructed of lightweight thermoplastic. Removable bezel and slip-on lamp terminals simplify maintenance and lamp replacement. Strong, compact and corrosion-resistant with a UL94V-0 flame rating. Remote Fixture INSTALLATION — Universal mounting plate for use with single or twin-head applications. Mounting plate: 5"H x 3-1/8"W. Mounts to single-gang switch box. LAMP — Glass sealed-beam PAR36 lamp(s). DIMENSIONS — Single: 4-3/4"W x 6-5/8"H. Twin: 13"W x 6-3/8"H. LISTING — Listed in accordance with UL 1598 and CSA C22.2 No. 250. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELA N0806 ELA Family Housing color ELA (blank) Desert tan W Ivory white B Black ITN Instrument tan Number of heads (blank) Single Fixture (blank) Standard PAR36 sealed-beam T Twin Lamp type (PAR36 sealed-beam) N0806 8W/6V incandescent N1206 12W/6V incandescent N1212 12W/12V incandescent N1812 18W/12V incandescent N2512 25W/12V incandescent H0606 6W/6V halogen H0806 8W/6V halogen H1206 12W/6V halogen H0812 8W/12V halogen H1212 12W/12V halogen Unit Accessories FEATURES & SPECIFICATIONS INTENDED USE To be powered by 6 or 12 volt battery equipment as part of an emergency lighting system providing light for the path of egress. This remote fixture matches applications using the ELSQ series. CONSTRUCTION Matte white polycarbonate frame and black thermoplastic housing are impactresistant and lightweight. ELA SQ Square Fixture Durable and corrosion-resistant with a UL94V-0 flame rating. Prismatic acrylic lens. Tungsten halogen lamp. Surface mounting. DIMENSIONS Single: 10-5/16"W x 10-5/16"L x 3-7/16"H. ORDERING INFORMATION Catalog Number ELA SQR6V ELA SQR12V Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA SQR6V Lamp Volts Watts No. 6 12 10 12 787 783 NOTE: For semi-recessed or fully recessed mounting, order additional kit ELA SRK or ELA FRK, respectively. Lithonia Lighting Sheet #: UE-406 © 1997 Acuity Brands Lighting, Inc., Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com VOLTAGE DROP TABLES The following information is provided to assist in planning layouts for emergency lighting systems. The National Code limits voltage drop to a maximum of 5% of nominal. Thus, circuit runs must be of sufficient size to maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting equipment. The table below shows the length of wire run based on system voltage, wire gauge and total wattage on the run. Formula: As per National Code standards, VD = 2 x L x I x R 1000 where L = length of run in feet I = current R = resistance of material at 75°C VD = voltage drop 6-VOLT SYSTEM Total watts 12 Wire size 10 8 12-VOLT SYSTEM 6 4 Total watts 12 length of wire run (feet) 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 73 63 55 44 37 34 31 27 24 22 21 18 18 15 13 11 9 9 7 6 4 4 3 3 2 2 2 1 1 116 100 87 70 58 54 50 44 39 35 33 29 28 23 20 17 15 14 12 9 7 6 5 4 3 3 3 2 2 185 159 139 111 93 86 79 70 62 56 53 46 44 37 32 28 23 22 19 15 11 9 9 6 6 5 4 4 3 294 252 221 176 147 136 126 110 98 88 84 74 71 59 50 44 37 35 29 24 18 14 12 10 9 8 7 6 4 Wire size 10 8 24-VOLT SYSTEM 6 4 Total watts 12 length of wire run (feet) 467 401 350 280 234 216 200 175 156 140 134 117 112 93 80 70 58 56 47 37 28 22 19 16 14 12 11 9 7 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 293 251 220 176 146 135 125 110 98 88 84 73 70 59 50 44 37 35 29 23 18 14 12 10 9 8 7 6 4 465 399 349 279 233 215 199 174 155 140 133 116 112 93 80 70 58 56 47 37 28 22 19 16 14 12 11 9 7 742 1,176 1,869 636 1,008 1,602 556 882 1,402 445 706 1,121 371 588 935 342 543 863 318 504 801 278 441 701 247 392 623 222 353 561 212 336 534 185 294 467 178 282 449 148 235 374 127 202 320 111 176 280 93 147 234 89 141 224 74 118 187 59 94 150 44 71 112 36 56 90 30 47 75 25 40 64 22 35 56 20 31 50 18 28 45 15 24 37 11 18 28 10 Wire size 8 6 4 length of wire run (feet) 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 1,171 1,103 878 702 585 540 502 439 390 351 334 293 281 234 201 176 146 140 117 94 70 56 47 40 35 31 28 23 18 1,860 1,595 1,395 1,116 930 859 797 698 620 558 532 465 447 372 319 279 233 223 186 149 112 89 74 64 56 50 45 37 28 2,967 2,543 2,225 1,780 1,483 1,369 1,271 1,112 989 890 848 742 712 593 509 445 371 356 297 237 178 142 119 102 89 79 71 59 44 4,706 4,034 3,529 2,824 2,353 2,172 2,017 1,765 1,569 1,412 1,345 1,176 1,129 941 807 706 588 565 471 376 282 226 188 161 141 125 113 94 71 7,477 6,409 5,607 4,486 3,738 3,451 3,204 2,804 2,492 2,243 2,136 1,869 1,794 1,495 1,282 1,121 935 897 748 598 449 359 299 256 224 199 179 150 112 UE-610 VOLTAGE DROP TABLES continued 32-VOLT SYSTEM Total watts 12 48-VOLT SYSTEM Wire size 10 8 6 4 Total watts 12 length of wire run (feet) 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 2,081 1,784 1,561 1,249 1,041 961 892 780 694 624 595 520 500 416 357 312 260 250 208 167 125 100 83 71 62 56 50 42 31 3,307 2,835 2,481 1,984 1,654 1,527 1,417 1,240 1,102 992 945 827 794 661 567 496 413 397 331 265 198 159 132 113 99 88 79 66 50 5,274 4,521 3,956 3,164 2,637 2,434 2,260 1,978 1,758 1,582 1,507 1,319 1,266 1,055 904 791 659 633 527 422 316 253 211 181 158 141 127 105 79 8,366 13,292 7,171 11,393 6,275 9,969 5,020 7,975 4,183 6,646 3,861 6,135 3,585 5,696 3,137 4,984 2,789 4,431 2,510 3,988 2,390 3,798 2,092 3,323 2,008 3,190 1,673 2,658 1,434 2,279 1,255 1,994 1,046 1,661 1,004 1,595 837 1,329 669 1,063 502 798 402 638 335 532 287 456 251 399 223 354 201 319 167 266 125 199 120-VOLT SYSTEM Wire size 10 8 6 Total watts Wire size 10 8 12 length of wire run (feet) 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 4,683 4,014 3,512 2,810 2,341 2,161 2,007 1,756 1,561 1,405 1,338 1,171 1,124 937 803 702 585 562 468 375 281 225 187 161 140 125 112 94 70 7,442 6,379 5,581 4,465 3,721 3,435 3,189 2,791 2,481 2,233 2,126 1,860 1,786 1,488 1,276 1,116 930 893 744 595 447 357 298 255 223 198 179 149 112 11,867 10,171 8,900 7,120 5,933 5,477 5,086 4,450 3,956 3,560 3,390 2,967 2,848 2,373 2,034 1,780 1,483 1,424 1,187 949 712 570 475 407 356 316 285 237 178 18,824 16,134 14,118 11,294 9,412 8,688 8,067 7,059 6,275 5,647 5,378 4,706 4,518 3,765 3,227 2,824 2,353 2,259 1,882 1,506 1,129 904 753 645 565 502 452 376 282 Example 1 Number of fixtures A 12V system uses 8-gauge wire and will operate three 7W exit signs. Total watts on wire run is 21, length of run from table is 212'. Multiplier Longer Wire Runs If loads are uniformly spaced along circuit path (equal watts, equal distances), the lengths in the table can be increased by certain values. Example 2 6 length of wire run (feet) 6 7 8 10 12 13 14 16 18 20 21 24 25 30 35 40 48 50 60 75 100 125 150 175 200 225 250 300 400 29,268 25,087 21,951 17,561 14,634 13,508 12,544 10,976 9,756 8,780 8,362 7,317 7,024 5,854 5,017 4,390 3,659 3,512 2,927 2,341 1,756 1,405 1,171 1,003 878 780 702 585 439 46,512 39,867 34,884 27,907 23,256 21,467 19,934 17,442 15,504 13,953 13,289 11,628 11,163 9,302 7,973 6,977 5,814 5,581 4,651 3,721 2,791 2,233 1,860 1,595 1,395 1,240 1,116 930 698 74,166 117,647 63,571 100,840 55,624 88,235 44,499 70,588 37,083 58,824 34,230 54,299 31,785 50,420 27,812 44,118 24,722 39,216 22,250 35,294 21,190 33,613 18,541 29,412 18,541 29,412 14,833 23,529 12,714 20,168 11,125 17,647 9,271 14,706 8,900 14,118 7,417 11,765 5,933 9,412 4,450 7,059 3,560 5,647 2,967 4,706 2,543 4,034 2,225 3,529 1,978 3,137 1,780 2,824 1,483 2,353 1,112 1,765 2 3 4 5 1.33 1.5 1.6 1.67 NOTE: To determine multiplier for six or more fixtures, use the following formula. Number of fixtures = Multiplier = n 2n n+1 Exit signs from Example 1 will be uniformly spaced. Multiplier is 1.5 for three fixtures. Maximum permissible length of wire run is 212' x 1.5, or 318'. Lithonia Lighting Sheet #: UE-610 © 1991 Lithonia Lighting, Rev. 6/97 Emergency Lighting Systems One Lithonia Way, Bldg. 3; Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS CONSTRUCTION Class II and III, Division 1 Corrosion-resistant, cast aluminum alloy with epoxy polyester finish. Top-mount fixture with single wall remote has universal junction box with four tapped holes for 3/4" rigid conduit (three close-up plug provided). ELA ZCD Twin wall remote has junction box with two tapped holes for 3/4" rigid conduit (one close-up plug provided). ELA ZCD H1212 UM fixture designed for direct mounting to ZX 1250N battery unit (ZX1250N unit not included). Utilizes 12W halogen lamps, 6V or 12V. ELECTRONICS Remote mount from area located outside the hazardous area via 6 VDC or 12 VDC battery unit. Hazardous Location Remote Lighting Fixtures CODES UL listed. Meets UL 924, 844, and 1203 illumination standards. UL listed for use in Class II, Division 1, Groups, E, F & G and Class III areas. WARRANTY Three-year total customer satisfaction warranty. For details, see Product Selection Guide. ORDERING INFORMATION ELA ZCD Remote Family ELA ZCD Hazardous combustible dust Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA ZCD H1212 WM Heads (blank) T Single Twin1 Lamp type Mounting G4 bi-pin H1206 12W/6V halogen H1212 12W/12V halogen WM Wall mount TM Top mount SM Side mount to ZX1250N unit Options WGZCD Wireguard NOTES: 1 Only available with wall mount unit. Emergency Sheet#: ELA ZCD SPUE - 340 ELA ZCD Hazardous Location Remote Lighting Fixtures SPECIFICATIONS DIMENSIONS LAMPS All dimensions are in inches (millimeters). Shipping weight: 18 lbs. (8 kgs.) Photometrics for 12 volt, 12 watt halogen head ELA ZCD H1206 TM ELA ZCD H1206 WM ELA ZCD H1212 SM ELA ZCD T H1206 WM Lithonia Lighting Sheet #: ELA ZCD © 1999 Acuity Brands Lighting,Inc., 10/16/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Suitable for use in Class I, Div. 1, Groups C & D, Zones 0, 1 & 2, Groups IIA, IIB + H2 & IIC; Class I, Div. 2, Groups C & D, Zone 2, Groups IIA, IIB + H2 & IIC; Class II, Div. 1, Groups E, F & G; Class I, Div. 2, Groups F & G and Class III hazardous location areas. CONSTRUCTION Copper-free cast-aluminum enclosure withstands pressure of explosions generated by internal arc without propagating them into the hazardous atmosphere. Enclosure has corrosion resistant, epoxy powder coat finish. Includes high-impact, heat-resistant globe with cast aluminum globe guard. Top and wall mount fixtures have a universal junction box with four tapped holes for 3/4" rigid conduit (three close-up plugs provided.) Pendant mount fixture has 3/4" top hub. Choose from a variety of halogen lamps. Seven watt compact fluorescent lamps also available. LISTING UL listed. Meets UL 924 and 844 illumination standards. WARRANTY Three-year total customer satisfaction warranty. For details, see Product Selection Guide. ORDERING INFORMATION ELA ZX Family Fixture ELA ZX Explosion-proof Emergency Lighting ELA ZX Hazardous Location Fixtures for use with ZX Family Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA ZX H0706 WM Lamp type Mounting Emergency only, G4 bi-pin H0706 7W/6V halogen H1006 10W/6V halogen H1206 12W/6V halogen H1212 12W/12V halogen WM Wall mount PM Pendant mount TM Top mount AC / emergency operation CF0706 7W compact fluorescent1 Accessories Order as a separate item ELA 3CH ELA SEA NOTES: 1 Only operates with ZX614N power pack in AC and emergency modes. The maximum mounting distance from the ZX 614N is 8'. See spec sheet UE-296 for more details. Emergency 3-way explosion-proof 3/4" conduit hub Swivel elbow arm for use with pendant mount fixture to connect to ELA 3CH or ELA ZX unit ELA EAK Exit accessory kit (red silk-screened letters on a white background) ELA SDR Straight dome reflector Sheet#: ELA ZX SPUE - 320 ELA ZX Hazardous Location Fixtures For Use With ZX Family SAMPLE APPLICATION DIMENSIONS All dimensions are in inches (millimeters). Shipping weight: 15 lbs. (7 kgs.) Wall Mount 10.4" (264) 14.3" (362) .8" (20) 7.3" The above sample application consists of: (1) ZX614N - 14 watt power pack for exclusive use with compact fluorescent fixtures (185) Top Mount (2) ELA SEA - Elbow arms (2) ELA ZX H0706 P- 7 watt compact fluorescent lamp fixture (1) ELA EAK - 7 watt compact fluorescent lamp fixture with exit accessory Pendant Mount 14.3" 14.9" (362) (378) 7.3" 7.3" (185) (185) ELA EAK (accessory) 17.8" (452) 12" (305) Lithonia Lighting Sheet #: ELA ZX ©1999 Acuity Brands Lighting, Inc., Rev. 10/16/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS CONSTRUCTION Impact-resistant, fiberglass reinforced polyester housing. Gray with stainless steel hardware. View-through window allows easy monitoring of AC indicator and optional voltmeter and ammeter. Class I, Division 2 Emergency Lighting Z Housing suitable for use in NEMA 4, 4X, 12 and 13 areas; Class I, Division 2, Groups A, B, C & D, Zone 2, Groups IIA, IIB + H2 & IIC and Class II, Division 2, Groups F & G. Lamp heads are Class I, Div. 2 rated polycarbonate sealed beam PAR36 tungsten or halogen lamps. Eight-watt tungsten lamps for 6-volt units and 12-watt tungsten lamps for 12-volt units are standard. Optional shatter-resistant shield is designed for use in food service areas. HAZARDOUS LOCATION UNITS 6 and 12 Volts, 25-125 Watts BATTERY Choice of sealed, maintenance-free lead-calcium battery or sealed, maintenance-free nickel-cadmium battery. 90-minute emergency operation at full light output. ELECTRONICS 120/277 VAC dual-voltage input with surge-protected, solid-state charging circuitry. Low-voltage disconnect (LVD) feature disconnects battery prior to unacceptable deep discharge, but not before the required 90-minute emergency operation. AC lockout prevents battery drain prior to energizing of utility power. Wiring and electrical connections can be completed without energizing emergency circuit. Brownout protection circuitry automatically switches unit into emergency mode if utility voltage drops below 20% of nominal. Battery charging circuitry utilizes constant-current charger for nickelcadmium battery units. Fully automatic, voltage-regulated charger used for lead-calcium battery units. Battery recharge time after full discharge less than required by UL 924 standard. DIAGNOSTICS Self-diagnostic option conducts automatic and manual tests, indicating real time status of lamp, battery and charger via tri-color indicator lamps. Automatic tests include systems analysis every 10 seconds, with actual load tests performed for a three-minute duration every 30 days, and for a 30-minute duration every 180 days. Manual tests include a three-, 30- and 90-minute battery discharge and lamp illumination tests. ORDERING INFORMATION Family 6V, lead-calcium Z625 25W 1 Z650 50W 1 Z6100 100W2,6 Z6125 125W 6 6V, nickel-cadmium Z625N 25W1,3 Z650N 50W1,3 12V, lead-calcium Z1225 25W1 Z1250 50W1,2 Z12120 120W 6 12V, nickel-cadmium Z1225N 25W1,3 Z1250N 50W1,3 Z1275N 75W1,3 Z12100N 100W1,3 Z12125N 125W1,3 CODES UL Listed. Meets UL 924 illumination standards. Select units additionally listed to UL 844, 1203 and 1604. NFPA 70 and NFPA 101 NEC and OSHA illumination standards. Units with nickel-cadmium batteries are also UL listed for Class II, Division 2, Groups F and G applications. WARRANTY Three-year total customer satisfaction warranty. Lead times will vary depending on options selected. Consult with your sales representative. Example: Z625 R1 N2506 SD Voltage4 (blank) 120/277 NOTES: 1 In addition to UL 924, units are listed to 844, 1203 and 1604. 2 Includes temperature compensated charger. 3 Nickel-cadmium units are the only units listed for Class II, Div. 2, Groups F and G applications. 4 Special voltages available. Consult factory. 5 Option configurations may impact UL listing. Consult factory for specifics. 6 Self-diagnostics is not available on Z6100, Z6125 and Z12120. 7 Only available with SD or SDA. Emergency TEST No. of lamps (blank) R1 R0 Two One None Lamp type Options 5 PAR 36 sealed-beam (blank) 8W/6V incand. N1806 18W/6V incand. N2506 25W/6V incand. N3006 30W/6V incand. H0806 8W/6V halogen H1206 12W/6V halogen (blank) N1812 N2512 N3012 H0812 H1212 12W/12V incand. 18W/12V incand. 25W/12V incand. 30W/ 12V incand. 8W/12V halogen 12W/12V halogen SD Self-diagnostics 6 SDA Self-diagnostics with alarm T D Time delay 120/2777 TD1 Time delay 120 VAC TD2 Time delay 277 VAC SRS Shatter-resistant lamp head shield Sheet #: Z SPUE-360 Z Class I, Division 2 Hazardous Location Emergency Lighting Units SPECIFICATIONS DIMENSIONS ELECTRICAL All dimensions are in inches (millimeters). Shipping weight: Input power requirements Z625 - 18 lbs. (8 kgs.) Z650 - 18 lbs. (8 kgs.) Z6100 - 27 lbs. (12 kgs.) Z6125 - 29 lbs. (13 kgs.) Z625N - 16 lbs. (7 kgs.) Z650N - 18 lbs. (8 kgs.) 120 VAC - .58 amps max., 65 watts max. 277 VAC - .27 amps max., 68 watts max. OPERATION DC Voltage Standard Lamp Head Unit Watts to 87½ of Rated Voltage 6 Z625 Z650 Z6100 Z6125 Z625N Z650N N0806 N0806 N0806 N0806 N0806 N0806 1 ½ hrs. 25 50 100 125 25 50 2hrs. 19 37.5 75 94 19 37.5 4hrs. 12 24 48 60 12 24 8hrs. 8.5 17 21.5 8.5 12 Z1225 Z1250 Z12120 Z1225N Z1250N Z1275N Z12100N Z12125N N1212 N1212 N1212 N1212 N1212 N1212 N1212 N1212 25 50 120 25 50 75 100 125 19 37.5 90 19 37.5 56.5 75 94 12 24 58 12 24 28.5 48 60 8.5 20 8.5 15 17 21.5 25 Watt to 75 Watt Units 16" (406) 12.4" (315) 10" (254) 100 Watt to 125 Watt Units Voltage Shelf Life1 Expected Life1 Maintenance 6 3 years 7-9 years none3 Optimum Temperature2 32°F - 100°F (0°C - 37.8°C) Voltage Shelf Life1 Expected Life1 Maintenance 6 and 12 6 months 5-8 years none3 18" (457) 14.4" (366) Lead-Calcium 12" (305) Optimum Temperature2 60°F - 90°F (16°C - 32°C) 15.2" (386) 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. o N0806 6 Volts, 8 Watts, PAR 36 o HORIZONTAL HORIZONTAL SPACING FACTOR 5 1.0 0.5 0.3 0 1.5 5 10 1.0 0.5 0.3 0.2 1.5 10 1.0 20 .5 Ft. VERTICAL FC 2.0 10 0.2 o 50 Hx25 V Medium Flood SPACING FACTOR 20 FC 2.0 7" (178) o N1212 12 Volts, 12 Watts, PAR 36 30 Hx20 V Narrow Flood 10 Ft. 6.5" (165) 13.2" (335) BATTERY Nickel-Cadmium 0 Z1225 - 29 lbs. (13 kgs.) Z1250 - 29 lbs. (13 kgs.) Z1225N - 18 lbs. (8 kgs.) Z1250N - 18 lbs. (8 kgs.) Z1275N - 20 lbs. (9 kgs.) Z12100N - 29 lbs. (13 kgs.) Z12125N - 29 lbs. (13 kgs.) Z12120 - 22 lbs. (10 kgs.) 1.0 VERTICAL .5 20 10 5 20 0 1.0 0.5 0.3 0.2 20 5 40 80 10 SPACING (FT) 0 60 GROSS LUMEN OUTPUT 110 10 10 20 30 40 REPLACEMENT LAMP #7613 50 20 1.0 0.5 0.3 0.2 25 10 40 60 80 SPACING (FT) GROSS LUMEN OUTPUT 177 20 15 Ft. 30 45 60 75 Ft. REPLACEMENT LAMP #4044 Lithonia Lighting Sheet #: Z ©1999 Acuity Brands Lighting, Inc., Rev. 10/16/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES CONSTRUCTION Explosion-proof Emergency Lighting Units Copper-free cast-aluminum enclosure withstands explosions generated by internal arc without propagating them into the hazardous atmosphere. Suitable for use in Class I, Div. I, Groups C & D, Zones 0, 1 & 2, Groups IIA, IIB + H2 & IIC; Class I, Div. 2, Groups C & D, Zone 2, Groups IIA, IIB + H2 & IIC; Class II, Div.1, Groups E, F & G; Class I, Div. 2, Groups F & G and Class III hazardous location areas. ZX Enclosure and cover constructed separately. Threaded cover allows easy attachment or removal. Enclosure has three threaded openings for 3/4" rigid conduit — one for AC input and two for mounting hazardous fixtures. All lamps heads and remotes must be ordered and shipped separately. See spec sheet UE-297 for more details. 6 AND 12 VOLTS 14-85 WATTS BATTERY Choice of sealed, maintenance-free nickel-cadmium battery or sealed, maintenance-free lead-calcium battery. 90-minute emergency operation at full light output. ELECTRONICS 120/277 VAC dual-voltage input with surge-protected, solid-state charging circuitry. Low-voltage disconnect (LVD) feature disconnects battery prior to unacceptable deep discharge, but not before required 90-minute emergency operation. AC lockout feature prevents battery drain prior to energizing of utility power. Wiring and electrical connections can be completed without energizing the emergency circuit. Brownout protection circuitry automatically switches unit into emergency mode if utility voltage drops below 20% of nominal. Battery charging circuitry utilizes constant-current charger for nickel-cadmium battery units. Fully automatic, voltage-regulated charger used for lead-calcium battery units. Battery recharge time after full discharge less than required by UL 924 standard. CODES UL Listed. Meets UL 924, 844, 1203, 1604, NFPA 70, NFPA 101, NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. For details, see Product Selection Guide. ORDERING INFORMATION Family Voltage3 6V, lead-calcium ZX685 85 watts 1 (blank) 120/277 6V, nickel-cadmium ZX614N 14 watts2 ZX628N 28 watts 12V, nickel-cadmium1 ZX1250N 50 watts Emergency Lead times will vary depending on options selected. Consult with your sales representative. Example: ZX614N TD1 Options KLD TD1 TD2 Key lock two-way, battery disconnect for servicing Time delay 120 VAC Time delay 277 VAC Accessories5 Order as separate items. ELA ZX DRH 12V,12W remote head4 NOTES: 1 Incandescent emergency lamp operation only. 2 Compatible only with ELA ZX remotes (spec sheet UE-297) using 7-watt compact fluorescent lamps. Will not operate incandescent lamps. Maximum remote mounting distance is 8'. 3 Some special voltages available. Consult factory. 4 Must be used with ZX1250N unit. 5 See spec sheet UE-297 for other accessories. Sheet#: ZX SPUE - 300 ZX Explosion-proof Emergency Lighting Units SPECIFICATIONS DIMENSIONS ELECTRICAL All dimensions are in inches (millimeters). Shipping weight: ZX614N - 63 lbs. (28 kgs.) ZX628N - 65 lbs. (29 kgs.) ZX1250N - 67 lbs. (30 kgs.) ZX685- 69 lbs. (31 kgs.) 120 VAC - .50 amps, 60 watts 277 VAC - .22 amps, 60 watts OPERATION DC Voltage 6 12 Unit ZX614N ZX628N ZX685 1 ½ hrs. 14 28 85 ZX1250N 50 Watts to 87½ of Rated Voltage 2hrs. 4hrs. 10.5 6.75 22.5 14.4 63.75 40.8 37.5 24 8hrs. 14.5 8.5 3-1/2 BATTERY 8-3/4 Lead-Calcium Voltage Shelf Life1 Expected Life1 Maintenance 6 6 Months 5-8 years none3 Optimum Temperature2 60°F–90°F (16°C–32°C) All dimensions are in inches (mm). Includes clearance holes for mounting with 1/2" bolts. ELA ZX DRH Accessory Nickel-Cadmium Voltage Shelf Life1 Expected Life1 Maintenance 6 and 12 3 years 7-9 years none3 Optimum Temperature2 4" (114) 32°F–100°F (0°C–37.8°C) 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 30 to 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 10" (254) Directional thread 7" (178) Directional thread allows for lamp head adjustability. Lithonia Lighting Sheet #: ZX © 1999 Acuity Brands Lighting, Rev. 12/11/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Provides minimum of 90 minutes of illumination for rated wattage upon loss of AC power. Unique design for light and heavy industrial applications, as well as heavy commercial environments. Superior performance lamp heads are ideal for higher mounting heights. CONSTRUCTION Rugged front and navy back (std. colors) .140” thick, injection-molded thermoplastic (large back housing is .187” thick, compression-molded composite). Vertical orientation, designed for pole or column mounting. Also suitable for wall, I-beam and unistrut mounting. Ceiling and pendant mounting with accessory equipment available on some models. Easy installation with epoxycoated, corrosion-resistant, 12-gauge steel mounting bracket shipped standard. U.S. Patent No. 6,135,624 - Mounting Bracket Utility patent. Conduit entry points located on top and both sides of unit. Maintenance made easy by toolless lamp replacement, hinged front cover, printed circuit board mounting shelf and battery belt. U.S. Patent No. D419,097 - Design patent. LAMPS U.S. Patent No. 6,193,395 - Lamp Head Utility patent. Full range of lamp options available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field-adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V and 12V. Standard lamp is 18W incandescent for 24V. BATTERY Sealed, maintenance-free, lead-calcium battery with capacity of 18W to 450W for 90 minutes of emergency operation. Available in 6V, 12V or 24V. Low voltage disconnect prevents excessively deep discharge that can permanently damage battery. Premium and Ultimate options offer high-temperature batteries (IND618, IND1236, and IND12100 only). UL listed from 0° C to 55° C (Premium) or -40° C to 55° C (Ultimate). ELECTRONICS Brownout protection is standard feature of self-diagnostics. AC/LVD reset prevents battery damage from deep discharge. Current limiting charger. Thermal protection prevents overheating and charger failure. Thermal compensation provides optimum charge voltage relative to ambient temperature. Dual voltage input capacity 120/277. Type Industrial Emergency Lighting Unit IND6/12/24 6, 12, or 24 Volts Sealed Lead-Calcium or Ni-Cad Battery DIAGNOSTICS (with Select, Premium and Ultimate packages) US Patent No. 6,502,044 - Self Diagnostics patent. Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Load learning capability self-calibrates to DC load at first test, enabling it to detect a lamp failure on future tests. May be re-calibrated at any time by holding down test switch for 15 seconds. LISTING UL Listed. Damp location listing. Meets UL 924, NFPA 101, NFPA 101-NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. Example: Family 6 Volts IND618 18 watts IND654 54 watts IND6100 100 watts1 12 Volts IND1236 36 watts IND1254 54 watts IND12100 100 watts IND12150 150 watts IND12300 300 watts IND12450 450 watts 24 Volts IND24100 100 watts IND24450 450 watts1 Emergency Housing Color (blank) Gray front/ Navy back W White Accessories Order as separate items. ELA RTT Remote test transmitter2 ELA WG2M Wire guard - small (18W-100W) ELA WGLG Wireguard - large (150-450W) ELA BS Banding strap ELA IND PM Pendant mount kit for IND618/654/6100 1236/1254/12100/241004 ELA IND CM1 Ceiling mount kit for IND618 ELA IND CM2 Ceiling mount kit for IND654/1236/1254 ELA IND CM3 Ceiling mount kit for IND6100 ELA IND R3 Pre-pack to install third head Option Packages Lamp Type (2 heads) (blank) Damp location 10° C to 40° C (50° F to 104° F). XTRA 2 Extra package. Features remote test, time delay and damp location 10° C to 40° C (50° F to 104° F). SEL Select package. Features self-diagnostics, time delay, audible failure indication and damp location 10° C to 40° C (50° F to 104° F). PREM3 Premium package. Features high-temperature ni-cad battery (IND618 and IND1236 only) or high ambient lead calcium battery (IND12100 only), self-diagnostics, time delay, audible failure indication and damp location. UL listed for 0° C to 55° C (32° F to 131° F). ULT 3 Ultimate package. Features heater, thermostat and battery blanket with a high temperature nicad battery (IND618 and IND1236 only) or highambient lead-calcium battery (IND12100 only), self-diagnostics, time delay, audible failure indication and damp location. UL listed for -40° C to 55oC (-40° F to 131° F). 6 Volts PAR36 Composite (blank) 9W/6V krypton H1206 12W/6V halogen H2006 20W/6V halogen 12 Volts PAR36 Composite (blank) 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen PAR36 Sealed-Beam H3512S 35W/12V halogen H5012S 50W/12V halogen 24 Volts PAR36 Composite (blank) 18W/24V incand. H2024 20W/24V halogen PAR36 Sealed-Beam N5024S 50W/24V incand. IND1236 H1212 ULT NOTES: 1 2 3 4 DL listed for indoor applications. Must order a Remote transmitter (ELA RTT). One per job required. Only available on IND618, IND1236 and IND12100. ELA IND PM accessory cannot be used with the IND12100 PREM or IND12100 ULT. Sheet #: IND6-12-24 INUE-100 IND6-12-24 INDURA Industrial Emergency Lighting Units, 6/12/24 Volts ELECTRICAL Primary Circuit AC Input Volts Amps Watts 120 .163 19.6 Type Output Watts Output Volts 1-1/2hr. 2hr. 3hrs. IND618 6 277 120 .069 .172 19.11 20.64 277 120 .075 .171 20.78 20.5 277 120 .064 .174 17.7 20.9 277 120 .078 .174 21.61 20.88 277 120 .078 .174 21.6 20.88 277 120 .074 .359 20.49 43.08 277 120 .168 .290 46.54 34.8 277 120 .130 .33 36.1 39.96 18 6 IND1236 IND1254 IND12100 54 100 75 50 37 12 36 27 18 13 12 54 40 27 20 12 100 75 50 37 150 12 IND24100 IND24450 277 .327 13.25 (336) 16 (406) 16 (406) Small Housing (18-54W; 100W Standard, XTRA, and SEL) Small Housing 112 75 8.68 (220) 56 300 225 150 12.5 (317) 12 450 337 225 168 24 100 75 50 37 24 450 337 225 168 ELA IND K0912 . One (1) 9 Watt Krypton In Vertical, Base Up Position HORIZONTAL 6 4 4 2 2 1 0 Voltage Shelf life Expected life1 Maintenance 6/12/24 3 yrs. 10 yrs. none3 Operating temperature2 32o-100oF (0o-37.8oC) Lead-Calcium 0.5 0.3 0 2 6/12/24 6 mos. Maintenance none3 5-8 yrs. 0.3 1 0.5 0.3 6 VERTICAL VERTICA VERTICAL VERTICA 6 6 4 4 2 1 0 0.5 0.3 0 2 2 4 4 6 6 10 1 Based on normal room temperatures and conditions. 2 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. 3 Periodic system status test recommended. 0.5 4 6 2 Operating temperature2 60o-90oF (16o-32oC) 1 2 4 20 30 40 Ft Ft. 10 20 30 Ft Ft. Center-to-center spacing* yields 25.5'. 25.5' FLOOD IND K0906 Medium Distribution 3' Center-to-center spacing* yields 26'. MEDIUM SPOT 12-gauge epoxy-coated steel mounting bracket included with each unit. Field-adjusted beam pattern for composite lamps. ELA RTT Order remote transmitter separately. *Note: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes space of 200'L x 200'W x 30'H, mounting height: 12', ceiling height: 30', and reflectances: 10/10/10. Analysis based on independently tested photometrics. 26' IND K0912 Medium Distribution Lithonia Lighting Sheet #: IND6-12-24 ©2004 Acuity Lighting Group, Inc., Rev. 03/06 Acuity Lighting Group, Inc. Emergency Lighting Systems One Lithonia Way, Bldg. 3 Conyers, GA 30035 Phone: 800-334-8694 www.lithonia.com .68 (17) . HORIZONTAL 6 Voltage 1 2.16 (25) (55) 0.40 (10) 12.5 (317) ELA IND K0906 One (1) 9 Watt Krypton In Vertical, Base Up Position 90.58 Expected life1 8.32 (211) 9 (228) 112 BATTERY Nickel-Cadmium Shelf life Mounting Bracket .20(5) 2.48(63) 2.76(70) IND12450 41.55 92.76 18 (457) 20 8 (203) IND12300 .15 .773 27 6 12 277 120 40 12 (305) IND12150 43.77 39.6 6 16 (406) IND6100 .15 .33 9 IND12150 - 45 lbs. IND12300 - 72 lbs. IND12450 - 75 lbs. IND24100 - 27 lbs. IND24450 - 75 lbs. Large Housing (100W PREM and ULT; 150-450W) Large Housing IND654 277 120 13.5 4hrs. All dimensions are in inches (millimeters). Shipping weight: IND618 - 13 lbs. IND654 - 18 lbs. IND6100 - 23 lbs. IND1236 - 18 lbs. IND1254 - 18 lbs. IND12100 - 27 lbs. 3' Catalog Number Notes FEATURES INTENDED USE Provides minimum of 90 minutes of illumination for rated wattage upon loss of AC power. Unique design for heavy and demanding industrial applications such as manufacturing plants, refineries, chemical plants, wastewater treatment facilities, food processing facilities, breweries, loading docks, and other applications subject to hosedown or industrial conditions. Superior performance lamp heads are ideal for higher mounting heights. CONSTRUCTION U.S. Patent No. D505,222 - Design patent. Rugged, heavy-duty, polycarbonate housing is sealed, gasketed, and corrosion-resistant. Unique vertical orientation is perfect for mounting to a pole, column, wall, I-beam or unistrut. Install with epoxy-coated, corrosion-resistant, 12-gauge steel mounting bracket shipped standard. Conduit entry points located at top and on both sides of unit. U.S. Patent No. 6,135,624 - mounting bracket utility patent. Maintenance is easy with hinged front cover, printed circuit board mounting shelf and battery belt. U.S. Patents pending. LAMPS U.S. Patent No.6,193,395 - lamp head utility patent. Full range of lamp options available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V and 12V. Standard lamp is 18W incand. for 24V. BATTERY Sealed, maintenance-free, lead-calcium battery with capacity of 18W to 125W for 90 minutes of emergency operation of 6V, 12V or 24V units. Premium and Ultimate options offer high-temperature batteries (INDX618, INDX1236, INDX12100 only). UL listed from 0° C to 55° C (Premium) or -40° C to 55° C (Ultimate). Low voltage disconnect prevents excessively deep discharge that can permanently damage battery. ELECTRONICS Brownout protection is a standard feature of self-diagnostics. AC/LVD reset prevents battery damage from deep discharge. Current limiting charger. Dual voltage input capacity (120/277V). Thermal protection prevents overheating and charger failure. Thermal compensation provides optimum charge voltage relative to ambient temperature. Type NEMA 4X Emergency Lighting Unit INDX 6, 12, or 24 Volts Sealed Lead-Calcium or Ni-Cad Battery ® DIAGNOSTICS (with Select, Premium and Ultimate packages) U.S. Patent No. 6,502,044 - Self-Diagnostics patent. Test switch provides manual activation of 30 second diagnostic testing (for on demand visual inspection). Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Load learning capability self-calibrates to DC load at first test, enabling it to detect a lamp failure on future tests. May be re-calibrated at any time by holding down test switch for 15 seconds. LISTING UL Listed. Meets UL 924, UL50, NFPA 101, NFPA 70-NEC, and OSHA illumination standards. NEMA 4, 4X rated. IP66 and NSF Listed. WARRANTY Three-year total customer satisfaction warranty. ORDERING INFORMATION Family Housing Color 6 Volts INDX618 18 watts INDX654 54 watts INDX6100 100 watts (blank) W Gray White 12 Volts INDX1236 36 watts INDX1254 54 watts INDX12100 100 watts1 INDX12125 125 watts 24 Volts INDX24100 100 watts Accessories Order as separate items. ELA RTT Remote test transmitter2 (for use with XTRA package, remote test option) ELA WGLG Wireguard - large ELA BS Banding strap ELA IND CM2 Ceiling mount kit for INDX654/1236/1254 Emergency Example: INDX12100 H1212 ULT Option Packages Lamp Type (2 heads) 6 Volts PAR36 Composite (blank) 9W/6V krypton H1206 12W/6V halogen H2006 20W/6V halogen 12 Volts PAR36 Composite (blank) 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen PAR36 Sealed-Beam H3512S 35W/12V halogen H5012S 50W/12V halogen 24 Volts PAR36 Composite (blank) 18W/24V incand. H2024 20W/24V halogen PAR36 Sealed-Beam N5024S 50W/24V incand. (blank) UL listed to 4X standards. XTRA2 Extra package features remote test and time delay. UL listed for 10° C to 40° C (50° F to 104° F). SEL Select package features self-diagnostics, time delay and audible failure indication. UL listed for 10° C to 40° C . PREM3 Premium package features high temperature ni-cad battery (INDX618 and INDX1236 only) or high ambient lead calcium battery (INDX12100 only), self-diagnostics, time delay, audible failure indication. UL listed for 0° C to 55° C (32° F to 131° F). ULT3 Ultimate package features heater, thermostat and battery blanket with a high temperature ni-cad battery (INDX618 and INDX1236 only) or a high-ambient leadcalcium battery (INDX12100 only), self-diagnostics, time delay and audible failure indication. UL listed for -40° C to 55° C (-40° F to131° F). NOTES: 1 INDX12100 available with either the PREM or ULT package only. 2 Must order a Remote transmitter (ELA RTT) sold separately. One per job required. 3 Only available on INDX618, INDX1236 and INDX12100. Sheet #: INDX INUE-140 INDX INDURA NEMA 4X Emergency Lighting Units, 6/12/24 Volts MOUNTING SPECIFICATIONS Dimensions : Measured in inches (millimeters). ELECTRICAL Primary Circuit Mounting Bracket AC Input Volts Amps Watts 120 .093 19.56 Type Output Watts Output Volts 1-1/2hr. 2hr. 3hrs. INDX618 277 120 .041 .171 .073 .144 .062 .174 18 13.5 9 6 6 54 40 27 20 6 100 75 50 37.5 12 36 27 18 13 12 54 40 27 20 1 2.16 (25) (55) 8 (203) 16 .20(5) 2.48(63) 2.76(70) 7-1/4 277 120 .078 .174 17.73 20.88 277 120 .078 .160 21.61 20.88 277 120 .072 .160 20.55 20.88 277 120 .072 .33 20.50 39.6 277 .15 41.55 INDX1254 INDX618 - 16 lbs. INDX654 - 20 lbs. INDX6100 - 28 lbs. INDX1236 - 20 lbs. INDX1254 - 20 lbs. INDX12100 - 36.5 lbs. INDX12125 - 30 lbs. 100 75 50 37.5 INDX24100 - 30 lbs. INDX K0912 9W (MID (MID) One 9-Watt Krypton, Vertical Base Up Pos. INDX K0906 INDURA 4X(NO LENS) LENS One 9 Watt Krypton, Horizontal Pos. HORIZONTAL HORIZONTAL 12 INDX24100 11-1/2 PHOTOMETRICS 12 INDX12125 .68 (17) Weight: Measured in pounds (kilograms). 20.22 18.24 INDX1236 INDX121004 6 20.78 20.52 INDX6100 277 120 4hrs. 19.11 20.64 INDX654 277 120 8.32 (211) 0.40 (10) 125 93 62 6 4 46 4 2 2 1 0 0.5 0.3 0 24 100 75 50 1 0.5 1 0.5 2 2 4 37 4 6 VERTICAL VERTICA VERTICAL VERTICA 6 4 4 2 BATTERY 2 1 0 0.5 0.3 0 2 2 Nickel-Cadmium 4 4 Voltage Shelf life Expected life1 6/12 3 yrs. 10 yrs. Maintenance none3 Operating temperature2 32o-100oF (0o-37.8oC) 6 10 20 30 40 50 60 Ft. Ft 10 20 30 40 50 Ft. Ft PERFORMANCE DIAGRAMS Center-to-center spacing* yields 21'. Lead-Calcium Voltage Shelf life Expected life1 6/12/24 6 mos. 5-8 yrs. Maintenance none3 21' Operating temperature2 60o-90oF (16o-32oC) 1 Based on normal room temperatures and conditions. 2 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. 3 Periodic system status test recommended. INDX K0906 Medium distribution Center-to-center spacing* yields 19'. 6' 19' *Note: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes space of 200'L x 200'W, mounting height: 16', ceiling height: 30', and reflectances: 10/10/10. Analysis based on independently tested photometrics. INDX K0912 Medium distribution 6' KEY FEATURES FLOOD MEDIUM SPOT ELA RTT 12-gauge epoxy-coated steel mounting bracket included with each unit. Vertical orientation for pole or column mounting. Field-adjusted beam pattern for composite lamps. Order remote transmitter separately. Lithonia Lighting Sheet #: INDX ©2004 Acuity Lighting Group, Inc., Rev. 9/05 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 In Canada: 160 avenue Labrosse, Point-Claire, P.Q. H9R 1A1 www.lithonia.com Catalog Number Notes FEATURES & SPECIFICATIONS Type INTENDED USE — Provides a minimum of 90 minutes illumination for rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation and unparalleled performance. CONSTRUCTION — White, compact, low-profile contemporary design. Engineeringgrade thermoplastic housing is impact-resistant, scratch-resistant and corrosionproof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and man-made light sources. Thermoplastic Emergency Light ELM 6-12 Two 9W wedge-base krypton lamps offer 80 percent more light output than the standard 9W incandescent lamps. Patented MR24, multi-faceted reflector significantly improves photometric performance – 48 percent more light delivered to the path of egress. Tool-less access for maintenance. Rigid conduit entry on both top and sides on large units (ELM654, ELM1254, and ELM1272), and top only for small units (ELM618 and ELM627). Universal J-box mounting pattern. HIGH CAPACITY UNITS Low-profile, integrated test switch/pilot light. Unique track and swivel arrangement permits full range lamp head adjustment. US patent No. D-532,918. Patent-pending Quick-Mount for simple installation. Ceiling mount standard. BATTERY — Sealed, maintenance-free lead-calcium battery standard. Sealed, maintenance-free nickel-cadmium battery optional. Automatic recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. ELECTRONICS — Universal input voltage capability (120 through 277V, 50 or 60 Hz). Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. DIAGNOSTICS (SD option) — Single multi-chromatic LED indicator to display twostate charging, test activation and three-state diagnostic status. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes bi-annually. Automatic test is easily postponed for eight hours by activating manual test switch. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality. Load learning capability self-calibrates to DC load at first test, enabling it to detect a lamp failure on future tests. It may be recalibrated at any time by holding down the test switch for 15 seconds. Filtered charger input minimizes charge voltage ripple and extends battery life. LISTING — UL listed. Damp Location listing available. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. WARRANTY — Three-year total customer satisfaction warranty. For details, see the Product Selection Guide. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELM618 Accessories Family Lamp type ELM618 6V, 18W ELM627 6V, 27W ELM654 6V, 54W ELM1254 12V, 54W ELM1272 12V, 72W 6-Volt MR 24 Composite (blank) 9W/6V krypton1 H1206 12W/6V halogen2 H2006 20W/6V halogen3 12-Volt MR 24 Composite4 (blank) 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen Options* B N TD RT SD R0 DL N0M Black housing9 Maintenance-free ni-cad battery5 Time delay6 Remote test7 Self-diagnostics6 Less Heads8 Damp Location5,10 - 100 - 400C (500-1040F) NOM Certified11 ELA LRT ELA VS2 ELA WG2M ELA MR24 *Options Availability Guide Product ELM618 ELM627 ELM654 ELM1254 ELM1272 Size S S L L L Emergency SD6 ■ ■ ■ ■ ■ TD6 RT7 N5 B9 ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ 11 DL5,10 R08 NOM ■ ■ ■ ■ ■ ■ ■ ■ NOTES: 1 Available on ELM618, ELM627, and ELM654 only. 2 Available on ELM627 and ELM654 only. 3 Available on ELM654 only. 4 Available on ELM1254 and ELM1272 only. 5 Available on ELM618, ELM627, and ELM1254 only. 6 SD and TD for ELM618 and ELM1254 must be ordered with N option. 7 RT not available with SD. Need to order the ELA LRT. Order as separate items. Remote test (laser) for distances up to 15' Polycarbonate vandal shield (1/8" thick) Wireguard Compact MR24 remote lamp head ELA MR24 K0606 (6W, 6V krypton) ELA MR24 K0906 (9W, 6V krypton) ELA MR24 H1206 (12W, 6V halogen) ELA MR24 K0912 (9W, 12V krypton) ELA MR24 H1212 (12W, 12V halogen) ELA MR24 H2006 (20W, 6V halogen) ELA MR24 H2012 (20W, 12V halogen) 8 Not available with any other options, except ELM1272 TD. 9 Available on ELM627 and ELM1272 only. 10 Damp Location listed from 100C to 400C (500 - 1040F) except ELM618N, ELM627N and ELM1254N listed from 150C to 320C (600 - 900F). 11 NOM available with ELM618 and ELM1254 only (not available with any other options). Sheet #: ELM 6-12 QMUE- 130 ELM 6-12 QUANTUM® Thermoplastic Emergency Light SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are in inches (millimeters). AC Input Max Volts Amps Watts 120 .167 5.2 Type ELM618 277 120 .072 .10 5.6 5.2 277 120 .04 .250 5.6 7.4 277 120 .108 .250 7.4 11 277 120 .108 .250 11.1 11 277 .108 11.1 ELM618 and ELM627 Dimensions (small housing) Output Watts Output Volts 1-1/2hr. 2hrs. 3hrs. 4hrs. 6 18 13.5 9 3 6 27 20 13.5 10 6 54 40.5 27 20 12 54 40.5 27 20 12 72 54 36 27 ELM627 ELM654 ELM1254 ELM1272 Shipping weight: ELM618 - 6.8 lbs. ELM627 - 8.0lbs. 12.79" (324.9) 7.01" (180.2) 4.73" (120.1) Shipping weight: ELM654 - 13 lbs. ELM1254 - 13 lbs. ELM1272 - 13 lbs. ELM654, ELM1254, and ELM1272 Dimensions (large housing) 12.79" BATTERY Nickel-Cadmium (324.9) Voltage Shelf life1 Expected life1 Maintenance 6/12 3 yrs. 10 yrs. none3 Operating temperature2 32o-100oF (0o-37.8oC) 7.01" (180.2) Sealed Lead-Calcium Voltage Shelf life1 Expected life1 Maintenance 6/12 1 yr. 5-8 yrs. none3 5.82" (147.8) Operating temperature2 60-90°F (16-32°C) ELM6-12 Backplate 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity to 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 7.01" (180.2) PERFORMANCE DIAGRAMS 12.79" (324.9) ELM12 Performance Advantage 33' • 12-volt, 9-watt krypton lamp • Typical 10 foot mounting height delivers 33 feet center-to-center spacing 10' • 48% increase in center-to-center spacings over competitive 12-volt higher capacity emergency lighting units. 3' ELM6 Halogen Performance Advantage 52' • 6-volt,20-watt halogen lamp • Higher mounting heights deliver 50+ feet • Recommended Center-to-Center Spacing Lamps center-to-center spacing 73% increase in center-to-center spacings over the highest wattage lamphead available from competitive emergency lighting units 7.5' 10' 12' 16' 20' K0606 25' N/A N/A N/A N/A K0906 25' 31' 29' 27' 23' K0912 25' 33' 30' 29' 26' H1212 N/A 31' 33' 39' 41' H2006 N/A 35' 37' 52' 49' Mtg Ht 16' 3' Lithonia Lighting Sheet #: ELM 6-12 ©2003 Acuity Brands Lighting, Inc., Rev. 5/30/08 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. CONSTRUCTION — White, compact, low-profile contemporary design with UVstabilized thermoplastic housing that is impact and scratch-resistant. Two 5.4W wedge-base krypton lamps offer 32 percent more light output than standard incandescent lamps. Thermoplastic Emergency Light ELM Patent-pending reflector/refractor design significantly improves photometrics. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Universal J-box mounting pattern. Lead-Calcium Battery Low-profile, integrated test switch/pilot light. Tool-less access for maintenance. Easily visible bright red status indicator. Flexible conduit entry provision on top of the unit. Ceiling mount standard. U.S. Patent No. D483,511 BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W to 18W (CSA) rated capacity. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. Galvanized battery retaining clip. ELECTRONICS — Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal. LISTING — UL Listed. NOM Certified. ELM and ELM DL meet UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. ELM CSR meets UL 1310 and UL73. WARRANTY — Three-year total customer satisfaction warranty. For details, see the Product Selection Guide. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELM ELM Family ELM Options CSR DL Eight-foot cordset (120V) Damp location listed (10o - 40oC)1 Accessories Order as separate items. NOTES: 1 Not available with CSR option. Emergency ELA VS Thermoplastic vandal shield ELA WGST Wireguard Sheet #: ELM QMUE - 100 ELM Quantum® Thermoplastic Emergency Light SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are inches (millimeters). Shipping weight: 3.0 lbs. (1.4 kgs.) Type Volts 120 AC Input Amps Watts .11 1.2 Output Volts ELM 6 277 .12 Watts Output 1/2hr. 1hr. 1-1/2hrs. 2hrs. * * 12 11.5" (292.1) 9 5" (127) 1.5 * Half hour and one hour run time not applicable for U.S. product. BATTERY Sealed Lead-Calcium Voltage 6 Shelf life1 6 mos. 3.75" (95.25) Expected life1 Maintenance 5-8 yrs. none3 Optimum temperature2 Mounting Plate 60-90°F (16-32°C) 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 30 to 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 1.91" (48.51) 2.5" (63.5) 5" 3.91" (127) (99.31) 5.63" (143) 3.75" (95.25) 11.5" (292.1) LAMP PHOTOMETRICS FIXTURE PERFORMANCE Consult factory for photometric information. Consult factory for fixture performance information. KEY FEATURES OPTION Unit snaps to mounting plate — no additional mechanical fasteners needed. ELM CSR option with eight-foot cordset. Lithonia Lighting Sheet #: ELM ©1991 Acuity Brands Lighting, Inc., Rev. 6/25/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES INTENDED USE — Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. CONSTRUCTION — White, compact, low-profile contemporary design. Engineering-grade thermoplastic housing is impact-resistant, scratch-resistant and corrosion-proof. UL94V-O flame rating. UV-stable resin resists discoloration from natural and man-made light sources. Two 5.4W wedge-based krypton lamps offer 32 percent more light output than standard incandescent lamps. Thermoplastic Emergency Light ELM2 Patented MR24, multi-faceted reflector significantly improves photometric performance – 60 to 100 percent more light delivered to path of egress. US Patent No. D484,272 Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Lead-Calcium Battery Low-profile, integrated test switch/pilot light. Easily visible bright red status indicator. Unique track-and-swivel arrangement permits full range of direction of lamp head adjustment. Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry provision on top of the unit. Ceiling mount standard. U.S. Patent No. D473,672 BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W rated capacity. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. Galvanized battery retaining clip. ELECTRONICS — Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. DIAGNOSTICS (SD option) — Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. Test switch provides manual activation of 30- second diagnostic testing for ondemand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Brownout protection is a standard feature of self-diagnostics. Continuously monitors AC functionality. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Automatic test is easily postponed for eight hours by activating manual test switch. LISTING — UL Listed and NOM Certified (standard). Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. Meets Mexican standards. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal. WARRANTY — Three-year total customer satisfaction warranty. For details, see the Product Selection Guide. Filtered charger input minimizes charge voltage ripple and extends battery life. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELM2 ELM2 Family ELM2 Options B DL SD Black housing1 Damp location listed (10oC to 40oC)1 Self-diagnostics Accessories Order as separate item. NOTES: 1 Black unit not available with damp location option. Emergency ELA VS Thermoplastic vandal shield ELA WGST Wireguard Sheet #: ELM2 QMUE-120 ELM2 QUANTUM® Thermoplastic Emergency Light SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are inches (millimeters). Shipping weight: 4.0 lbs. (1.8 kgs.) Type AC Input Amps Watts .11 1.2 Volts 120 Output Volts ELM2 6 277 .12 11.5" (292.1) Watts Output 1-1/2hrs. 2hrs. 12 9 5" (127) 1.5 * Half-hour and one-hour run time not applicable for U.S. product. BATTERY 3.75" (95.25) Sealed Lead-Calcium Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2 6 6 mos. 5-8 yrs. none3 60-90°F (16-32°C) Mounting Plate 1.91" (48.5) 5" (127) 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 30 to 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 2.5" (63.5) 3.91" (99.3) 5.63" (143) 3.5" (88.9) 11.5" (292.1) 3.75" (95.25) 12.5" (317.5) FIXTURE PERFORMANCE LAMP PHOTOMETRICS LTL10586 MR24 K0606 6-volts, 5.4-watts krypton Center-to-Center Spacing* yields 20' HORIZONTAL 6 4 Single-Unit Coverage* yields 18' 2 1 0 0.5 0.3 0.1 FC min. 2 1 FC average 4 6 VERTICAL 6 4 18 ft. 2 1 0 0.5 6-Foot Path of Egress 0.3 6 ft. 2 4 6 10 20 Ft. Center-to-Center Spacing* yields 25' SPACING/COVERAGE GUIDE MR24 K0606 Lamp Path of Egress 3'-wide 6'-wide Center-to-Center Spacing 25' 20' Single-Unit Coverage 24' 18' 0.1 FC min. Single-Unit Coverage* yields 24' 1 FC average 24 ft. 3-Foot Path of Egress 3 ft. * Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 7.5’, ceiling height: 9’, and reflectances: 80/50/20. Analysis based on independently tested photometrics. Lithonia Lighting Sheet #: ELM2 © 1991 Acuity Brands Lighting, Inc., Rev. 6/25/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Guideline Specification Electronics General TM The emergency lighting unit shall be of the Affinity family manufactured by Lithonia Emergency Systems. It shall conform to the requirements of the UL924 standards. Housing Construction: The unit housing shall be a die-cast aluminum, tear-shaped housing (U.S. Patent no. D468.046). Dimensions shall not exceed 6-1/2” W x 9-1/2” H x 27/10” D. Mounting: Unit shall be wall-mounted. Universal Jbox mounting pattern should be provided. A conduit entry point shallbe located on top of the unit. Maintenance: Unit shall be maintained easily with a single tool entry. Color: The housing color shall be specified as brushed nickel or polyester powder coat textured paint in white, black, or dark bronze. Optical System The patent-pending reflector/refractor design shall feature vac-metalized, die-casted reflectors; a highly transmissive, multi-faceted refractor; and two 6-watt, wedgebased, xenon lamps rated for 105 lumens. It shall deliver spacing at 26’ on center* to meet the Life Safety Code of one foot candle average and 0.1 foot candle minimum, as well as the max-to-min ratio of 40:1. * Assumes open space with no obstructions, 3’-wide path of egress, 8.5’ mounting height, 9’ ceiling height, and 80/50/20 reflectances. Battery Batteries shall be 6-volt, sealed, maintenance-free, lead calcium or high-temperature nickel cadmium -- providing 12-watt rated capacity for 90 minutes of emergency operation. The electronics shall include AC/LVD reset, which allows battery connection before AC power is initially applied and prevents battery damage from deep discharge. The electronics shall also include brownout protection and DC fuse and a solid-state charger that provides automatic recharge after a discharge. The circuitry shall provide thermal protection to sense circuitry temperature and adjust charge current to prevent overheating and charger failure and thermal compensation to adjust charger output to provide optimum charge voltage relative to ambient temperature. Self-Diagnostics (Premium and Exterior Option Packages) The patented (U.S. Patent No. 6,502,044) self-diagnostics shall provide a single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. And a test switch that provides manual activation of 30-second diagnostic testing for on-demand visual inspection. The self-diagnostic testing will occur for five minutes every 30 days and 30 minutes every six months for diagnostic evaluation of lamps, AC to DC transfer, charging and battery condition. This option will continuously monitor AC functionality. Option Packages Premium Package: Includes high-temperature, nicad battery, self-diagnostics, and damp location listing from 0o C to 50o C. Exterior Package: Includes high-temperature, ni-cad battery, self-diagnostics, and wet location listing from -18o C to 50o C (0o F to 122o F). Warranty A warranty for three-year total customer satisfaction shall be included. Lithonia Lighting Form No. 680.211 Rev. 08/03 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE — Provides a minimum of 90 minutes illumination for the rated wattage upon loss of AC power. Ideal for applications requiring low-profile, attractive emergency lighting. ® CONSTRUCTION — Compact, low-profile, architectural design with die-cast aluminum housing that has a contemporary brushed nickel-plated finish. Other available finishes are texturized polyester powder coat paint in white, black and dark bronze. All finishes can be painted in the field to match the wall color of choice. Die-Cast Architectural Emergency Light AFN U.S. Patent No. D468,046. Two 6W wedge-base xenon lamps offer 55 percent more light output than standard incandescent lamps. Meets requirements for NEC 700.16. Patent-pending reflector/refractor design features superior vac-metalized, diecasted reflectors; and multi-faceted, highly transmissive refractor that significantly improve photometrics. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Universal J-box mounting pattern. Low-profile, integrated test switch/pilot light located below the lens. Easily visible green status indicator. Rigid conduit entry provision on top of the unit. BATTERY — Sealed, maintenance-free lead-calcium battery provides 12W rated capacity. Nickel-cadmium battery with Premium and Exterior option packages. Automatic 48-hour recharge after a 90-minute discharge. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Single-circuit battery connection. ELECTRONICS — Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Brownout protection is automatically switched to emergency mode when supply voltage drops below 80 percent of nominal. ORDERING INFORMATION SELF-DIAGNOSTICS (SD option) Patented Electronics - U.S. Patent No. 6,502,044. Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Continuously monitors AC functionality. Postpone automatic test initiates eight hour delay of an automatic test by activating the manual test switch. LISTING — UL listed. Wet location (EXT) listed. Damp location (PREM, EXT) listed. Cold weather (EXT) listed. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. UL labeled. WARRANTY — Three-year warranty. For shortest lead times, configure product using standard options (shown in bold). Example: AFN W EXT AFN Family AFN Affinity Series die-cast architectural emergency lighting Finish W White B Black BN Brushed nickel DB Dark bronze1 Option packages (blank) Features lead calcium battery PREM Features ni-cad battery, self-diagnostics and damp location 0° to 50°C (32° to 122°F) EXT Features high-temperature ni-cad battery listed from -18° to 50°C (0° to 122°F), self-diagnostics. Listed for cold weather, damp and wet location T D Time delay2 NOTES: 1 Dark bronze can only be ordered with EXT option. This finish will not be available on other units. 2 Only available in black EXT option. Emergency Accessories Order as separate item. ELA AFNR DB Remote fixture (less batteries and electronics) to be powered by 6V battery equipment as part of an emergency lighting system (listed from -18oC to 50oC), W, B finishes available.2 Sheet #: AFN ARC-60 AFN Affinity® Die-Cast Architectural Emergency Light FIXTURE PERFORMANCE SPECIFICATIONS ELECTRICAL Primary Circuit AC Input Volts Amps Watts 120 .11 1.1 Type Output Volts AFN 6 277 120 .12 .15 1.3 1.4 277 120 .14 .23 1.4 21 AFN PREM AFN EXT 277 .25 Center-to-Center Spacing on a 3-foot Path of Egress Watts Output 1-1/2hrs. 26 ft . 12 1 FC average 6 12 6 12 0.1 FC min. 35 BATTERY Sealed Lead-Calcium 3 ft. Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2 6 6 mos. 5-8 yrs. none3 60-90°F (16-32°C) Center-to-Center Spacing on a 6-foot Path of Egress 21 ft. Nickel-Cadmium Voltage Shelf life1 Expected life1 Maintenance Optimum temperature2 6 3 yrs. 7-9 yrs. none 3 32-122°F (0-50°C) 1 FC average 1 At 77°F (25°C). 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. See option packages for expanded temperature ranges. Consult factory for detailed information. 3 Periodic system status test recommended. 0.1 FC min. 6 ft. MOUNTING SPACING GUIDE All dimensions are inches (millimeters). Shipping weight: 3.5 lbs. (1.59 kgs.) 2-7/10 (68.58) 4 3/8 (85.73) 9-1/2 (241.3) 2-7/10 (68.58) 4 3/8 (85.73) 9-1/2 (241.3) 6-1/2 (165.1) 9-1/2 (241.3) Xenon Lamp Path of Egress 3'-wide Path of Egress 6'-wide Center-to-Center Spacing 26' 21' NOTE: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 8.5', ceiling height: 9', and reflectances: 80/50/20. 6-1/2 (165.1) Test switch status indicator Lithonia Lighting Sheet #: AFN © 2003 Acuity Brands Lighting, Inc., Rev. 9/28/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS CONSTRUCTION Contemporary Cylinder Emergency Light Black 16-gauge steel backplate and housing. Contemporary white plastic cylinder shroud with high temperature plastic optical lens. Both are UV stabilized. Sturdy adjustable cast-aluminum swivel. ELCC One 8W halogen wedge-base lamp (single) or two 6W halogen wedge-base lamps (twin). Wall or ceiling mount. LEAD-CALCIUM BATTERY Dual-voltage input capability (120V or 277V). Test switch provides manual activation of functional testing. Status indicator provides visual monitoring of normal AC power. BATTERY Sealed, maintenance-free lead-calcium battery provides 12W rated capacity. Automatic recharge after a 90-minute discharge. Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery. ELECTRONICS Brownout protection. Current-limiting charger maximizes battery life and minimizes energy consumption. Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/undercharging that shortens battery life and reduces capacity. AC/LVD allows battery connection before AC power is applied and prevents battery damage from deep discharge. Unit should not be left in reset mode for more than 72 hours. CODES UL listed. Meets UL 924, NFPA 101 (current Life Safety Code), NFPA 70 – NEC. WARRANTY Three-year total customer satisfaction warranty. For details, see Product Selection Guide. ORDERING INFORMATION For shortest lead times, configure product using standard options (shown in bold). Example: ELCC ELCC Family ELCC Options (blank) T Emergency Single lamp head Twin lamp heads Sheet#: ELCC SPUE-130 ELCC Emergency Light, Contemporary Cylinder SPECIFICATIONS DIMENSIONS ELECTRICAL Primary Circuit All dimensions are in inches (millimeters). Supply voltage 120 277 AC input watts 5.8 5.9 Max. amps .052 .023 VA 6.2 6.4 BATTERY Sealed Lead-Calcium Voltage Shelf life1 Expected life1 Maintenance Optimum temperature 2 6 6 mos. 5–8 yrs. none 3 60–90°F 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. 4-1/2 (114) 4-1/2 (114) Lithonia Lighting Sheet #: ELCC © 1998 Acuity Brands Lighting, Inc., Rev. 11/8/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com Catalog Number Notes Type FEATURES INTENDED USE Emergency Recessed Series Provides 90 minutes of illumination for the rated wattage upon the loss of AC power. Ideal for applications that require attractive unit equipment or when wall mounting is undesirable. CONSTRUCTION ELR2/ELR2P/ELR4 Durable polycarbonate faceplate finished in architectural white. Hinged faceplate and adjustable mounting hardware speed up and simplify installation/maintenance. Two 8W (ELR2) or two 12W glass sealed-beam lamps. Heads rotate 359° to meet aiming requirements. Dual-voltage input capability (120V or 277V). 6-Volt, Self-Contained, 12-Volt, 50-Watt U.S. Patent No. 6,502,044. BATTERY Sealed, maintenance-free lead-calcium battery provides 16W (ELR2) or 50W (ELR4) rated capacity. Optional nickel-cadmium battery provides 16 watts (ELR2 N) or 24 watts (ELR2P N). Ensures long life over wide temperature ranges. Automatic battery recharge after 90-minute discharge. Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Slip-on battery terminals. ELECTRONICS Brownout protection standard on ELR4. Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Short-circuit protection – current-limiting charger circuitry and fused output circuit (ELR4) protect printed circuit board from shorts. Thermal protection senses circuitry temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/under charging that shortens battery life and reduces capacity. Filtered charger output minimizes charge voltage ripple and extends battery life. AC/LVD reset allows battery connection before AC power is applied and prevents battery damage due to deep discharge. DIAGNOSTICS (SD Option) Single multi-chromatic LED indicator to display two-state charging, test activation and three-state diagnostic status. Test switch provides manual activation of 30-second diagnostic testing for ORDERING INFORMATION on-demand visual inspection. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Brownout protection is a standard feature of self diagnostics. Continuously monitors AC functionality. Automatic test is easily postponed for eight hours by activating manual test switch. Load-learning capability self-calibrates to DC load at first test enabling it to detect a lamp failure on future tests. It may be recalibrated at any time by holding down the test switch for 15 seconds. INSTALLATION Wall or ceiling mount. Exposed or concealed suspension ceiling systems. Suitable for use in air-handling plenums. 21-gauge galvanized mounting box fits into opening (10-7/10" H x 10-7/10" W x 3-1/2" D). T-bar clips secure unit to grid in ceiling-mount applications. All hardware supplied. T-bar clips secure unit to grid in ceiling-mount applications. LISTING UL listed. Meets UL924, NFPA 101-1985 (current Life Safety Code) and NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. For complete details, see warranty sheet in Product Selection Guide. Lead times will vary depending on options selected. Consult with your sales representative. Example: ELR2 Options Family ELR2 ELR2P ELR4 6V, 16W 6V, 24W1 12V, 50W Emergency TD AM VM 220V/50HZ H N1812 N2512 R0 N CDS SD Integral time delay (18 minutes) 2,3 Ammeter 2 Voltmeter 2 220 or 240V, 50 or 60 Hz input Two 8W halogen lamp heads Two 18W, 12V incandescent lamp heads3 Two 25W, 12V incandescent lamp heads3 Less lamp heads Maintenance-free nickel-cadmium battery 4 Compact designer square lamp heads Self-diagnostics 3 NOTES: 1 Available with nickel-cadmium battery only. 2 Choice of two. Not available with AM, VM and TD on one unit. 3 ELR4 only. 4 Not available with ELR4. Sheet #: ELR2-2P-4 SPUE-100 ELR2/ELR2P/ELR4 Emergency Recessed Series SPECIFICATIONS DIMENSIONS ELECTRICAL Primary Circuit All dimensions are inches (millimeters), unless otherwise specified. Shipping Weight: AC Input Volts Amps Watts 120 .167 20 Type 277 120 .072 .250 20 30 277 .108 30 Watts Output1 1-1/2hrs. 2hrs. 3hrs. 4hrs. Output Volts ELR2 ELR4 ELR2 16 lbs. (7.3 kgs.) ELR4 22.5 lbs. (10.2 kgs.) 6 16 - - - 12 50 38 25 18 BATTERY Sealed Lead-Calcium Voltage ELR2 6 ELR4 12 Shelf life2 Expected life2 Maintenance Optimum temperature 3 6 mos. 5-8 yrs. none 4 60o-90 o F Shelf life2 Expected life2 Maintenance Optimum temperature 3 3 yrs. 10 yrs. none 4 32 o -100o F Nickel-Cadmium Voltage ELR2 6 ELR2P N 6 1 Watts to 87-1/2% of nominal voltage. 2 At 77°C. 3 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for more details. 4 Periodic system status test recommended. PHOTOMETRICS 30oHx20oV Narrow Flood N0806 6 Volts, 8 Watts, PAR 36 HORIZONTAL SPACING FACTOR 10 FC 2.0 5 0 1.0 0.5 0.3 20 0 1.5 5 1.0 0.5 0.3 0.2 1.5 10 1.0 20 .5 Ft. VERTICAL 10 50oHx25oV Medium Flood SPACING FACTOR FC 2.0 10 0.2 10 Ft. N1212 12 Volts, 12 Watts, PAR 36 HORIZONTAL 1.0 VERTICAL .5 20 5 20 0 1.0 0.5 0.3 0.2 20 5 40 80 10 SPACING (FT) 0 60 GROSS LUMEN OUTPUT 110 10 10 20 30 40 50 REPLACEMENT LAMP #7613 Ft. 20 1.0 0.5 0.3 0.2 20 10 40 60 80 SPACING (FT) GROSS LUMEN OUTPUT 177 20 15 30 45 60 75 Ft. REPLACEMENT LAMP #4044 KEY FEATURES SELF-DIAGNOSTICS OPTION z Five-minute test every 30 days z 30-minute test every six months z Diagnostics evaluate the battery, lamp, charger and AC to DC transfer. Ceiling mount – mounts to T-bar by adjustable bar hangers. Wall mount – mounts to wood or metal studs with bar hangers. Also, rough-in for dry walls. Condition Normal mode Self-testing Emergency mode Hi-charge Battery failure Lamp failure Circuit failure Indication Steady green Flashing green Off Steady red Single-flash red Double-flash red Triple-flash red Lithonia Lighting Sheet #: ELR2-2P-4 ©1997 Acuity Brands Lighting, Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES CONSTRUCTION Emergency Recessed Gimbal Dual-voltage input capability (120V or 277V). All-metal housing and gimbal assembly. ELRG Matte white baked enamel finish. High-output 8-watt halogen lamp head. Lamp adjusts in two planes to 26°. Low profile pilot light and test switch. Approved for use in air handling plenums. Emergency Operation Comes standard with bar hangers. BATTERY Sealed, maintenance-free lead calcium battery provides 10 watts rated capacity. 24-hour recharge after 90-minute discharge. Low voltage disconnect prevents excessively deep discharge that permanently damages the battery. ELECTRONICS Current limiting charger maximizes battery life and minimizes energy consumption. Short-circuit protection. Current limiting charger circuitry protects printed circuit board from shorts. Thermal protection senses circuit, temperature and adjusts charge current to prevent overheating and charger failure. Regulated charge voltage maintains constant charge voltage over a wide range of line voltages. Prevents over/under charging that shortens battery life and reduces capacity. Brownout protection AC/LVD — allows battery connection before AC power is applied and prevents battery damage from deep discharge. Unit should not be left in reset mode for more than 72 hours. CODES UL listed. Meets UL924, NFPA 101 (current Life Safety Code) and NFPA 70-NEC. WARRANTY Three-year warranty. ORDERING INFORMATION All configurations of this product are considered "standard" and have short lead times. Example: ELRG Family ELRG Emergency lighting recessed gimbal Emergency Sheet #: ELRG SPUE-120 ELRG Emergency Recessed Gimbal SPECIFICATIONS DIMENSIONS Length: 8-3/8 (213) ELECTRICAL Width: 8-3/8 (213) Primary Circuit Depth: 8-1/4 (210) Weight: 6.5lbs (3kgs.) Supply voltage AC input watts Max. amps VA 120 277 5.8 5.9 .052 .023 6.2 6.4 All dimensions are inches (millimeters) unless otherwise specified. BATTERY Sealed Lead-Calcium Voltage Shelf life1 Expected Optimum life1 Maintenance temperature 2 6 6 Months 5–8 years none 3 60–90°F NOTES: 1 At 77°F. 2 Optimum ambient temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for detailed information. 3 Periodic system status test recommended. PHOTOMETRICS ELRG 6-volts, 8 watts, halogen HORIZONTAL 4 2 0 1 0.5 0.3 1 0.5 0.3 20 30 2 4 VERTICAL 4 2 0 2 4 10 Ft. Replacement Lamp # 785 Lithonia Lighting Sheet #: ELRG ©1997 Acuity Brands Lighting, Inc., Rev. 1/2/08 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com Catalog Number Notes Type SPECIFICATIONS INTENDED USE Ideal for applications requiring unobtrusive, emergency lighting. Available flushed, semi-recessed or recessed. CONSTRUCTION Unobtrusive, contemporary housing design with ivory white Lexan® frame and black Noryl®* base is impact- and fire-resistant (UL 94V-0 flame rating). Efficient 10W or two 8W (with 2L option) tungsten halogen lamps provide high lumen output. White cone reflector and acrylic prismatic lens (Lexan lens with 2L option) provide wide beam spread. Mitered corners and recessed lens give a clean, finished appearance. Push-to-test lens conceals test switch and "ready" light. Dual-voltage input (120V or 277V). BATTERY Sealed, maintenance-free lead-calcium battery provides 10W (ELSQ) or 20W (ELSQM) rated capacity. Automatic battery recharge after 90-minute discharge (120-minute discharge with 2L option). Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Slip-on battery terminals. ELECTRONICS Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Thermal protection senses temperature and adjusts charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages. Prevents over/under charging that shortens battery life and reduces capacity. Filtered charger output minimizes charge voltage ripple and extends battery life. AC/LVD reset permits testing of unit at time of installation and ensures full 90minute discharge. 80% brownout protection and high charge indicator (2L option only). MOUNTING Wall or ceiling mount. J-box mounting pattern. ORDERING INFORMATION Family ELSQ 6V, self-contained ELSQM 6V, 20W Emergency Square Series ELSQ/ELSQM 6-Volt, Self-Contained 6-Volt, 20-Watt Surface mounting standard. For semi-recessed and fully recessed, order accessory kits ELA SRK and ELA FRK, respectively. All hardware supplied. LISTING UL listed. Meets current Life Safety Code, NEC and OSHA illumination standards. WARRANTY Three-year warranty. * Lexan and Noryl are registered trademarks of G.E. For shortest lead times, configure product using standard options (shown in bold). Example: ELSQ Options 2L Two 8W lamps with Lexan lens and high charge indicator (ELSQM only)1 LEX Lexan lens (standard with 2L option) N Maintenance-free nickel-cadmium battery 1 Accessories Order as separate items. ELA SRK Semi-recessed kit ELA FRK Fully-recessed kit NOTES: 1 2L option is UL listed for a two-hour run time, not available with nickelcadmium battery. Emergency Sheet #: ELSQ M SPUE - 110 ELSQ/ELSQM Emergency Square Series SPECIFICATIONS DIMENSIONS ELECTRICAL All dimensions are inches (millimeters), unless otherwise specified. Primary Circuit AC Input Volts Amps Watts 120 .092 20 Type Output Volts ELSQ 277 120 .042 .092 20 20 277 .042 20 ELSQM Watts Output1 1-1/2hrs. 2hrs. 3hrs. 6 10 - - 6 20 16 10 Shipping Weight: ELSQ 5 lbs. (2.3 kgs.) ELSQM 6.5 lbs. (3 kgs.) BATTERY Sealed Lead-Calcium Voltage 6 Shelf life2 6 mos. Expected life2 5-8 yrs. Maintenance none 4 Optimum temperature 3 60 o-90 oF Expected life2 5-8 yrs. Maintenance none 4 Optimum temperature 3 32 o-100oF Sealed Nickel-Cadmium Voltage 6 1 2 3 4 Shelf life2 3 yrs. Watts to 87-1/2% of 6V. At 77°C. Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for more details. Periodic system status test recommended. Rated Output Capacity in Watts - Emergency Run Time ELSQ N ELSQM N 1.5 hrs. 10 20 2 hrs. -15 3 hrs. -10 KEY FEATURES Semi-recessed mounting accessory kit – ELA SRK. Fully-recessed mounting accessory kit – ELA FRK. Lithonia Lighting Sheet #: ELSQ M ©1997 Acuity Brands Lighting, Inc., Rev. 9/28/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES & SPECIFICATIONS INTENDED USE Provides a minimum of 90-minutes of illumination for the rated wattage upon the loss of AC power. Ideal for applications that require ensconced emergency lighting in wall or ceiling. CONSTRUCTION Trim and door panels finished in durable white textured powder coated paint. Can be wall papered or field painted. Trim and panel doors lay flush with mounting surface. No exposed hardware. Low profile recessed test switch and status indicator configuration minimizes exposed interfaces. Rugged, 22 GA galvanized steel box with three 3/4" knock-outs. Galvanized bar hangers span up to 30" on center. Vertically adjustable bar hangers allows for flush mounting of trims to ceiling face, accomodates ceiling or walls up to 5/8" thick. LAMPS Two MR16 halogen 12W to 75W lamps. Fully adjustable to meet aiming requirements. Lamps are ensconced until activated in the emergency mode. Models with additional wattage capacity are provided with fused remote output leads. BATTERY Sealed, maintenance-free lead-calcium battery with capacity of 24W to 150W for a minimum of 90-minutes of emergency operation. Optional nickelcadmium battery. Extended runtimes available. (See chart on reverse side.) Automatically recharges after a 90-minute discharge. Low voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Voltage polarity protected connector for reverse polarity protection. INSTALLATION Wall or ceiling mount. Exposed or concealed suspension ceiling systems. T-bar clips secure unit to grid in ceiling-mount applications. Rough-in dimensions: 13-1/2" x 6-3/4. Allow 5-1/2" for door panel opening clearance. ELECTRONICS Dual-voltage input capability (120/277V). Precision controlled motor and cam system ensures reliable extraction and retraction of light sources. Single, multi-chromatic LED indicator to display two-state charging, test activation and four-state diagnostic status. ORDERING INFORMATION Concealed Emergency Lighting Unit VELARÉ 12-VOLT SELF-DIAGNOSTIC, SEALED LEAD-CALCIUM OR NI-CAD BATTERY Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Self-diagnostics is provided as a standard feature. The diagnostic feature tests the unit once every 28 days by opening the doors for 1 second and then closing them, without turning the lamps on. Following this, a load test will be performed for 29 minutes checking for lamp, battery or transfer default. The charger function is monitored continuously. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Continuously monitors AC functionalilty. IR receiver is provided as a standard feature. Requires the ELA RTVEL hand-held remote transmitter for remote testing (see accessories) for operation. Selectable 30-second or 90-minute testing. LISTING UL listed. Meets UL 924, NFPA 101, NFPA 70-NEC and OSHA illumination standards. WARRANTY Three-year warranty. For shortest lead times, configure product using standard options (shown in bold). Example: VEL1270 H3512 Family1 Lamp Type4 Options VEL1224 (12V, 24W) VEL1240 (12V, 40W) H1212 12W/12V halogen MR16 H2012 20W/12V halogen MR16 N Maintenance-free ni-cad T D Time delay LRIS Less rough-in section5 VEL1270 (12V, 70W)2 VEL12100 (12V, 100W) 3 VEL12150 (12V, 150W) 3 H3512 35W/12V halogen MR16 H5012 50W/12V halogen MR16 H7512 75W/12V halogen MR16 NOTES: 1 For extended run-time information, see chart on reverse side. 2 Not available with H1212 lamps. 3 Not available with H1212 or H2012 lamps. 4 Two lamps provided. Total lamp load cannot exceed the fixture capacity rating. 5 VEL rough-in section ships standard with fixture unless LRIS suffix is specified. The rough-in section ships in a separate carton. 6 Minimum one per job required for remote testing. Emergency Accessories Order as separate items. ELA RTVEL Remote infra-red hand-held transmitter with selectable 30second or 90-minute testing6 ELA VEL RIS VEL rough-in section (supplied standard with fixture unless LRIS suffix is specified) ships with mounting hardware only. Order ELA VEL RIS if needed for rough-in phase of construction Sheet #: VEL ARC-20 VEL Concealed Emergency Lighting Unit, Velaré SPECIFICATIONS DIMENSIONS ELECTRICAL All dimensions are in inches (millimeters), unless otherwise specified. Shipping Weight: VEL1224 H1212 LRIS (12V, 24W) - 12.5 lbs. VEL1240 H2012 LRIS (12V, 40W) - 12.5 lbs. VEL1270 H3512 LRIS (12V, 70W) - 15 lbs. VEL12100 H5012 LRIS (12V, 100W) - 15 lbs. VEL12150 H7512 LRIS (12V, 150W) - 19.5 lbs. ELA VEL RIS (rough-in) - 11 lbs. Primary Circuit AC Input Max Output Type Volts Amps Watts 120 .20 30 VEL1224 277 .20 30 Watts Volts Output 1-1/2hr. 12 24 12 40 120 .20 30 277 .20 30 VEL1270 120 277 .20 .20 30 30 12 70 VEL12100 120 277 .20 .20 30 30 12 100 VEL12150 120 277 .20 .20 30 30 12 150 VEL1240 Rough-in opening: 13-1/2 (341) x 6-3/4 (170) Overlap trim: 14-7/16 (365) x 7-5/8 (193) Allow 5-1/2" for door panel opening clearance. 13 1/2” to 30” 16” Universal, Adjustable Mounting Rails 2 per unit Mount on 13 ½” or 16” sides. Depth Behind Wall For 3/4” wall thickness = 3 1/4” Total Depth = 4” Ceiling / Wall Thickness = 1/8” to 3/4” 13 1/2” Rough In Opening BATTERY 6 3/4” Rough In Opening Sealed Lead-Calcium Voltage Shelf life1 Expected life1 Maintenance 12 6 mos. 5-8 yrs. none 2 Operating temperature 60 o-90 oF (0o-37.8oC) Back Box and Mounting Dimensions PHOTOMETRICS NIckel-Cadmium Recommended Center-to-Center Spacing Expected life1 Maintenance 12 3 yrs. 10 yrs. none 2 Operating temperature 32-100°F (16-32°C) Ceiling Height Lamp Type Voltage Shelf life1 NOTES: 1 At 77°F (25°C). 2 Periodic system status test recommended. EXTENDED RUN- TIME CHART 10' 12' 16' H1212 17' 17' 16' 16' H2012 36' 36' 34' 34' 64' 20' H3512 65' 65' 58' H5012 70' 70' 70' 70' H7512 130' 140' 134' 140' Please use the chart below to determine which model number to use to achieve an extended run time of two, three, or four hours. Example: If you require a 4-hour run time, the lowest wattage unit available is the VEL1240 H1212. The units are not loaded to full capacity which in turn extends the run time. Lamp Wattage Run-Time Needed (2) H1212 Lamps (2) H2012 Lamps (2) H3512 Lamps 65' (2) H5012 Lamps (2) H7512 Lamps 1-1/2 Hrs. VEL1224 H1212 VEL1240 H2012 VEL1270 H3512 VEL12100 H5012 VEL12150 H7512 2 Hrs. VEL1224 H1212 VEL1240 H2012 VEL1270 H3512 VEL12150 H5012 3 Hrs. VEL1224 H1212 VEL1270 H2012 VEL12100 H3512 VEL1270 H2012 VEL12150 H3512 4 Hrs. VEL1240 H1212 12' 6' KEY FEATURES Velare - 35W MR16 at a 12' ceiling height Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes fixture is ceiling mounted in a 200'Wx200'L open area and reflectances of 80/50/20. Front Panel Diagnostic Display Hi Charge Float/Full Charge 90 Min. 30 Sec. Note: All spacings are intended to be guidelines. Results will vary if application deviates from dimensions or assumptions stated above. Diagnostic Functions Battery Failure Lamp Failure Transfer Failure Charger Failure Door Failure In test Self Diagnostics is standard Motor and cam system Remote transmitter hand-held accessory Lithonia Lighting Sheet #: VEL ©2005 Acuity Brands Lighting, Inc., Rev. 9/28/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax: 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES INTENDED USE Ideal for applications where steel housing or metal lamp heads are a requirement. CONSTRUCTION 18-gauge steel housing finished in instrument tan color. Hinged faceplate for easy maintenance. Two 12-watt incandescent glass sealed-beam lamps in thermoplastic housings. Dual-voltage input capability (120 or 277 volts) BATTERY Batteries are sealed, maintenance-free, lead-calcium with wattage capacities of 125, 180 or 275 watts for 90 minutes of emergency operation. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. ELECTRONICS AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Current limiting charger maximizes battery life and minimizes energy consumption. Thermal protection senses circuitry temperature and adjust charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. LISTING UL listed. Meets UL 924, NFPA 101, NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide). ORDERING INFORMATION Industrial Steel Emergency Lighting ELT125 ELT180 ELT275 STANDARD LEAD-CALCIUM BATTERY For shortest lead times, configure product using standard options (shown in bold). Example: ELT125 Family Input voltage1 Housing color Lamp heads Lamp type Options ELT125 125W/12V (blank) 120V/277V (blank) Instrument tan (blank) Two heads PAR36 sealed-beam Ammeter 3 Voltmeter 3 8W halogen lamps Load disconnect switch T D Integral time delay NOM NOM Certified ELT180 180W/12V ELT275 275W/12V NOTES: 1 Other voltages available. Consult factory. 2 Must be ordered with the MT option. 3 AM and VM must be ordered together. Emergency W White RO Less lamp heads MT Metal lamp heads (blank) 12W/12V incandescent N2512 H1212 H3512 H5012 25W/12V 12W/12V 37W/12V 50W/12V incandescent halogen halogen2 halogen2 AM VM H LD Accessories Order as separate items. ELA WG 4/8 Large wireguard (50-275W) ELA MST Mounting shelf Sheet #: ELT-125-180-275 INUE-220 ELT125/ELT180/ELT275 Industrial Steel Emergency Lighting SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are inches (millimeters). Shipping weight: ELT125 - 43.5 lbs. (19.7 kgs.) ELT180 - 58.5 lbs. (26.5 kgs.) ELT275 - 61.5 lbs. (27.9 kgs.) Type AC Input Volts Amps Watts 120 .250 30 Output Watts Output Volts 1-1/2hr. 2hr. 3hrs. ELT125 277 120 .108 .287 30 50 277 120 .125 .287 50 50 277 .125 50 ELT180 ELT275 4hrs. 12 125 93 67 46 12 180 135 90 67 12 275 206 137 103 * Watts to 87-1/2% of nominal voltage. BATTERY Sealed Lead-Calcium ELT125 ELT180 ELT275 Voltage Shelf life1 Expected life1 Maintenance2 Optimum temperature3 12 6 mos. 5-8 yrs. none 60°-90°F 1 At 77°C. 2 Periodic system status test recommended. 3 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for more details. LAMP SPECIFICATIONS Spacing Factor: Indicates the proper spacing between lamps to the chosen illuminance level (fc) ± 20%. Footcandle Curves: Show distances in feet and isocurves in footcandles. Lithonia Lighting Sheet #: ELT-125-180-275 ©2000 Acuity Brands Lighting, Inc., Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES INTENDED USE Ideal for applications where steel housings or metal lamp heads are a requirement. CONSTRUCTION 18-gauge steel housing finished in instrument tan color. Hinged faceplate for easy maintenance. Two 8-watt (ELT16, ELT24, ELT36) or 12-watt (ELT50) incandescent glass sealed-beam lamps in thermoplastic housings. Dual-voltage input capability (120 or 277 volts) BATTERY Batteries are sealed, maintenance-free, lead-calcium with wattage capacities for 90 minutes of emergency operation. 16-watts (ELT16), 24-watts (ELT24), 36-watts (ELT36) and 50-watts (ELT50). Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. ELECTRONICS AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from deep discharge. Current limiting charger maximizes battery life and minimizes energy consumption. Thermal protection senses circuitry temperature and adjust charge current to prevent overheating and charger failure. Thermal compensation adjusts charger output to provide optimum charge voltage relative to ambient temperature. LISTING UL listed. Meets UL 924, NFPA 101, NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide). ORDERING INFORMATION Family ELT16 ELT24 ELT36 ELT50 16W/6V 24W/6V 36W/6V 50W/12V ELT16, ELT24, ELT36, ELT50 STANDARD LEAD-CALCIUM BATTERY OPTIONAL NICKEL-CADMIUM For shortest lead times, configure product using standard options (shown in bold). Example: ELT36 Input voltage1 Housing color Lamp heads Lamp type Options (blank) 120V/277V (blank) Instrument tan W White (blank) Two heads RO Less heads MT Metal lamp heads PAR36 sealed-beam 6 Volts (blank) 8W/6V incandescent N1806 18W/6V incandescent H1206 12W/6V halogen 12 Volts (blank) 12W/12V incandescent N2512 25W/12V incandescent H1212 12W/12V halogen (blank) None LD Load disconnect switch T D Integral time delay3,5 N Nickel-cadmium battery 2 AM Ammeter 3,4 VM Voltmeter3,4 H 8W halogen lamps6 NOM NOM Certified NOTES: 1 Other voltages available. Consult factory. 2 N is not available with ELT36. 3 ELT50 uses larger housing when ordered with these options (see ELT-125-180-275 spec sheet for larger housing dimensions). 4 AM and VM must be ordered together. 5 Available on ELT50 only. 6 H option is a 6W lamp on the ELT24. Emergency Industrial Steel Emergency Lighting Accessories Order as separate items. ELA WG2 Small wireguard (16W-50W) ELA MSTS Mounting shelf Sheet #: ELT-16-24-36-50 INUE-200 ELT16/ELT24/ELT36/ELT50 Industrial Steel Emergency Lighting SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit Shipping weight: All dimensions are inches (millimeters). AC Input Volts Amps Watts 120 .163 16.6 Type Output Watts Output Volts 1-1/2hr. 2hr. 3hrs. ELT16 277 .069 16.4 120 .167 20 277 .072 20 120 .172 17.8 277 .075 18.0 120 .287 30 277 .108 30 ELT24 ELT36 ELT50 4hrs. 6 16 12 8 6 6 24 24 16 12 6 36 27 18 13.5 12 50 37 25 18 ELT16 ELT24 ELT36 ELT50 ELT50 - 12.8 lbs. (5.8 kgs.) - 12.8 lbs. (5.8 kgs.) - 17.3 lbs. (7.8 kgs.) - 17.3 lbs. (7.8 kgs.) - (large housing) 30.5 lbs. (13.8 kgs.)* * Watts to 87-1/2% of nominal wattage. BATTERY Sealed Lead-Calcium Voltage ELT16 ELT24 ELT36 ELT50 6 6 6 12 Maintenance2 Shelf Life1 Expected Life1 6 mos. 5-8 yrs. Shelf life1 Expected life1 3 yrs. 10 yrs. Optimum temperature3 60o-90oF none Nickel-Cadmium ELT16 ELT24 ELT50 Voltage 6 6 12 Maintenance2 none Optimum temperature3 32o-100oF * For ELT50 (large housing) dimensions, reference spec sheet#: UE205. 1 At 77°C. 2 Periodic system status test recommended. 3 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for more details. LAMP SPECIFICATIONS Spacing Factor: Indicates the proper spacing between lamps to the chosen illuminance level (fc) ± 20%. Footcandle Curves: Show distances in feet and isocurves in footcandles. Spacing Factor: Indicates the proper spacing between lamps to the chosen illuminance level (fc) ± 20%. Footcandle Curves: Show distances in feet and isocurves in footcandles. Lithonia Lighting Sheet #: ELT-16-24-36-50 ©2000 Acuity Brands Lighting, Inc, Rev. 12/17/07 Emergency Systems Group One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 Fax 770-981-8141 www.lithonia.com Catalog Number Notes Type FEATURES CONSTRUCTION 18-gauge steel housing finished in instrument tan color. Hinged faceplate for easy maintenance. Metal lamp heads with two 12-watt tungsten halogen, glass sealed-beam PAR36 lamps. Industrial Steel Emergency Lighting Dual-voltage input capability (120 or 277 volts) BATTERY ELT24C/ ELT36C Maintenance-free lead-calcium battery provides 24 watts (ELT24C) or 36 watts (ELT36C) rated capacity for two hours. 24-hour battery recharge after 90-minute discharge. Test switch and dual function ready/charge light (green) permit check of system operation. Low-voltage disconnect prevents excessively deep discharge that can permanently damage the battery. Slip-on battery terminals. ELECTRONICS LEAD-CALCIUM BATTERY Current-limiting charger maximizes battery life and minimizes energy consumption. Provides low operating costs. Yellow AC "on" light. CODES UL listed. Meets UL 924, NFPA 101-1988 (current Life Safety Code), NEC and OSHA illumination standards. ELT24C and ELT36C are approved for use in the city of Chicago (9717-E). WARRANTY Three-year total customer satisfaction warranty. (For complete details, see warranty sheet in Product Selection Guide). ORDERING INFORMATION Example: ELT24C H LD Accessories Family ELT24C ELT36C Emergency Options AM VM CS RO H LD Ammeter Voltmeter 3-foot cordset - 120V only Less lamp heads 8W halogen lamps Load disconnect switch Order as separate items. ELA WG2 ELA MSTS Wire guard Mounting shelf Sheet#: UE-215 INUE-240 ELT24C/ELT36C Industrial Steel Emergency Lighting SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are inches (millimeters). Shipping weight: ELT24C - 12.5 lbs. (5.7 kgs.) ELT36C - 17.0 lbs. (7.7 kgs.) Type ELT24C ELT36C AC Input Volts Amps Watts 120 .167 20 277 .072 120 .167 20 277 .072 Output Watts Output* Volts 1-1/2hr. 2hr. 3hrs. 4hrs. 6 24 24 16 12 6 36 36 24 18 * Watts to 87-1/2% of nominal wattage. BATTERY Sealed Lead-Calcium ELT24C Voltage Shelf life1 Expected life1 Maintenance2 Optimum temperature3 6 6 mos. 5-8 yrs. none 60o-90oF 1 At 77°C. 2 Periodic system status test recommended. 3 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. Consult factory for more details. LAMP SPECIFICATIONS Spacing Factor: Indicates the proper spacing between lamps to the chosen illuminance level (fc) ± 20%. Footcandle Curves: Show distances in feet and isocurves in footcandles. Lithonia Lighting Sheet #: UE-215 ©2000 Acuity Brands Lighting, Inc., Rev. 2/12/07 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 770-922-9000 www.lithonia.com