3 Port Solenoid Valve

Transcription

3 Port Solenoid Valve
3 Port Solenoid Valve
VP300/500/700
Series
ced
Redu
powe
w
5
5
.
0 w
.55
1
[With
rd]
)
h DC
∗ Wit
Series
VP300
light
 Built-in full-wave rectifier (AC)
 Noise
Power consumption is reduced
by power saving circuit.
Power consumption is decreased by approx. 1/3 by reducing
the wattage required to hold the valve in an energized state.
(Effective energizing time is over 40 ms at 24 VDC.) Refer to
electrical power waveform as shown below.
Electrical power waveform of energy saving type
Applied voltage
24 V
RoHS
it]
g circu
savin
power
[Standa
W
l: 2.0
a
tion
ven
(Con
tion:
ump
r cons
reduction
Noise is considerably reduced by changing it to DC mode with
a full-wave rectifier.
 Reduced
apparent power
Conventional: 5.6 VA → 1.55 VA
 Longer life expectancy:
50 million cycles or more
(Conventional: 20 million cycles) ∗ Based on SMC test conditions
 Built-in strainer in the pilot valve
Unexpected troubles due to foreign matter can be prevented.
0V
Note) Be sure to mount an air filter on the inlet side.
Rubber material: HNBR
Ozone-resistant specification
Standard
1.55 W
Energy saving
0.55 W
∗ The pilot valve poppet is made of FKM.
With power saving circuit
0W
40 ms
Strainer
SYJ
Air Operated Valve
VQZ
Series
VPA300/500/700
P.2263
VP
VG
VP3
1831
Series VP300/500/700
Model Selection by Operating Conditions q
Solenoid Valve: Single Unit
Series
Sonic conductance
C [dm3/(s·bar)]
VP300
Type of actuation
Port
size
Voltage
Internal pilot
N.C.
Electrical
entry
Light/surge
voltage suppressor
Manual
override
Grommet
2(A)
4.2
Body ported
VP500
(P)1 3(R)
1/8
1/4
L-type plug
connector
N.O.
Non-locking
push type
2(A)
(P)1 3(R)
8.9
1/4
3/8
P.1834
M-type plug
connector
External pilot
N.C./N.O.
VP700
2(A)
15.3
(P)1 3(R)
3/8
1/2
Solenoid valve
X
24 VDC
24 VAC
100 VAC
VP300
110 VAC
2(A)
(P)1 3(R)
1/8
1/4
N.O.
Base mounted
220 VAC
AC
240 VAC
 With light/surge
voltage suppressor
Push-turn
locking
slotted type
(P)1 3(R)
8.8
External pilot
N.C.
2(A)
1/4
3/8
(P)1 3(R)
N.O.
2(A)
15.0
(P)1 3(R)
X
Push-turn
locking
lever type
Conduit
terminal
X
VP700
1832
 With surge voltage
suppressor
 With light/surge
voltage suppressor
 With surge voltage
suppressor
(Non-polar)
 With light/surge
voltage suppressor
(Non-polar)
DIN (EN1753
01-803)
terminal
2(A)
VP500
DIN
terminal
200 VAC
Internal pilot
N.C.
3.8
DC
12 VDC
3/8
1/2
P.1841
Series VP300/500/700
Model Selection by Operating Conditions w
Solenoid Valve: Manifold
Series
Applicable
stations Note)
Manifold
base model
EXH port
type
VV3P3-41
Common EXH
3(R) port
1/4
VP300
1(P) port
1/4
2(A) port
1/4
1(P) port
1/4
2(A) port
1/4
VV3P3-42
2 to 20
stations
Individual EXH
3(R) port
1/4
VV3P5-41
Base mounted
Solenoid valve
Common EXH
3(R) port
3/8
VP500
1(P) port
3/8
2(A) port
3/8
1(P) port
3/8
2(A) port
3/8
VV3P5-42
2 to 20
stations
P.1848
Individual EXH
3(R) port
3/8
VV3P7-41
SYJ
VQZ
Common EXH
VP
1(P) port
1/2
3(R) port
1/2
VP700
2(A) port
1/2
VV3P7-42
VG
2 to 20
stations
VP3
Individual EXH
3(R) port
1/2
1(P) port
1/2
2(A) port
1/2
Note) Supply pressure to 1(P) ports and exhaust air from 3(R) ports on both sides for 10 stations or more.
1833
Rubber Seal
3 Port/Pilot Poppet Type
Body Ported/Single Unit
Series VP300/500/700
Note) Only DIN and conduit terminal types
are available for AC mode.
Refer to the electrical entry for details.
How to Order
VP 3 4 2
Body ported
Series
3
5
7
5 G
1 01
Pilot type
VP300
VP500
VP700
Nil
R
Thread type
Internal pilot
External pilot
Nil
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Bracket
Rc
G
NPT
NPTF
F
N
T
Pressure specification
Nil
A
Nil
F
Without bracket
With bracket
Coil specification
Nil
T
Standard
With power saving circuit (DC only)
Note) Be sure to select the power saving circuit type when it is continuously energized for a long time.
(Refer to page 1861 for details.)
∗ T type is only available for DC mode.
When T is selected, only Z type of
light/surge voltage suppressor is
available.
(Note that when the electrical entry of
DIN terminal type without connector is
selected, only DOS and YOS are
available.)
Rated voltage
Type of actuation
DC
5 24 VDC
6 12 VDC
A N.C. (Normally closed)
B N.O. (Normally open)
Port size
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
Symbol
01
02
03
04
X500
L-type plug
connector
M-type plug
connector
VP300
VP500
VP700
Made to Order
Nil
Electrical entry
Grommet
Port size
1/8
1/4
3/8
1/2
DIN
Conduit
(EN175301-803)
terminal
terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
—
Pilot exhaust port with piping thread (M3)
specification (Refer to page 1857).
Interchangeable specification with the
DIN
terminal
X505 previous valve mounting hole pitch type
(Refer to page 1857).
X600 Triac output specification (Refer to page 1857).
Manual override
G: Lead wire
Nil: Non-locking
push type
D: Push-turn locking
E: Push-turn locking
slotted type
lever type
L: With lead wire M: With lead wire
length 300 mm (length 300 mm) (length 300 mm)
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal
LN:
MN:
Without lead wire Without lead wire
Light/Surge voltage suppressor
Nil
G: Lead wire
S
Z
R
U
length 300 mm
H: Lead wire
length 600 mm
DC
Without light/
surge voltage LO:
suppressor
Without connector
CE DC
compliant AC Note)
—
—
MO:
DO:
YO:
Without connector
Without connector
Without connector
—
∗ LN and MN types are with 2 sockets.
∗ Refer to page 1859 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to page 1860 for details on the DIN (EN175301-803) terminal.
Note) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking
compliant.
1834
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
DC
AC
Note)
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the connector,
DOZ, DOU, YOZ, YOU are not available.
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to page 1862 for
details.
Pilot Poppet Type
Body Ported/Single Unit
Low power consumption 1.5 W (DC)
Possible to use as either a
selector or divider valve
Possible to change from
N.C. to N.O.
• Refer to page 1862 for changing
the type of actuation.
Possible to use in vacuum
applications
Up to –100 kPa
Series VP300/500/700
Specifications
Fluid
Type of actuation
Standard
Internal pilot
Operating pressure range (MPa) High-pressure type
Standard
External pilot
High-pressure type
Operating pressure range (MPa)
Pilot pressure range
Ambient and fluid temperature (°C)
Max. operating frequency (Hz)
Manual override
Series VP300
Pilot exhaust type
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2) Note)
Enclosure
Air
N.C. or N.O. (Convertible)
0.2 to 0.7
0.2 to 1.0
–100 kPa to 0.7
–100 kPa to 1.0
Same as operating pressure (Min. 0.2 MPa)
–10 to 50 (No freezing)
5
Non-locking push type
Push-turn locking slotted type
Push-turn locking lever type
Individual exhaust
Not required
Unrestricted
300/50
Dust-tight (IP65 for D, Y, T)
Note) Impact resistance:
No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
Series VP500
Solenoid Specifications
DIN terminal (D)
Grommet (G), (H)
DIN (EN175301-803) terminal (Y)
L-type plug connector (L)
Conduit terminal (T)
M-type plug connector (M)
G, H, L, M
D, Y, T
24, 12
DC
Coil rated voltage (V)
24, 100, 110, 200, 220, 240
AC (50/60 Hz)
±10% of rated voltage∗
Allowable voltage fluctuation
1.5 (With light: 1.75)
1.5 (With light: 1.55)
Standard
Power consumption (W) DC
0.75 (With light only)
0.55 (With light only)
With power saving circuit
1.5 (With light: 1.75)
1.5 (With light: 1.55)
24 V
100 V
110 V
[115 V]
Apparent power (VA)∗ AC
1.55 (With light: 1.7)
1.55 (With light: 1.65)
200 V
220 V
[230 V]
240 V
Diode (Non-polar type: Varistor)
Surge voltage suppressor
LED (Neon bulb is used for AC mode of D, Y, T.)
Indicator light
Electrical entry
Series VP700
External Pilot
Use external pilot type in the following
cases:
• For vacuum or for low pressure 0.2 MPa or
less
• Please consult with SMC for use in a
vacuum hold application.
• When having P port downsized in diameter
• When using A port as the atmospheric
releasing port, e.g. air blower
Made to Order
(Refer to page 1857 for details.)
X500
X505
X600
Pilot exhaust port with piping
thread (M3) specification
Interchangeable specification
with the previous valve mounting
hole pitch type
Triac output specification
∗ It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
∗ Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable
voltage fluctuation should be within the following range.
24 VDC: –7% to +10%
12 VDC: –4% to +10%
Response Time
Model
VP342
VP542
VP742
Response time ms (at 0.5 MPa)
Pressure specifications Without light/surge With light/surge voltage suppressor
voltage suppressor
S, Z type
R, U type
13 or less
Standard (0.2 to 0.7)
38 or less
16 or less
17 or less
High-pressure type (0.2 to 1.0)
42 or less
20 or less
Standard (0.2 to 0.7)
14 or less
39 or less
17 or less
High-pressure type (0.2 to 1.0)
18 or less
43 or less
21 or less
Standard (0.2 to 0.7)
19 or less
44 or less
22 or less
High-pressure type (0.2 to 1.0)
22 or less
47 or less
25 or less
SYJ
VQZ
VP
VG
VP3
AC
38 or less
42 or less
39 or less
43 or less
44 or less
47 or less
Note) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated voltage)
1835
Series VP300/500/700
Flow Characteristics/Weight
Model
Port size
C [dm3/(s·bar)]
3.5
4.2
7.9
8.9
11.9
15.1
1/8
1/4
1/4
3/8
3/8
1/2
VP342
VP542
VP742
1 ↔ 2 (P ↔ A)
b
0.26
0.22
0.21
0.16
0.21
0.21
Cv
0.8
1.0
1.8
2.2
2.7
3.6
2 ↔ 3 (A ↔ R)
b
0.26
0.23
0.27
0.20
0.20
0.22
C [dm3/(s·bar)]
3.6
4.2
7.2
8.9
11.8
15.3
Weight (g) Note)
Grommet
DIN terminal
149
185
145
181
249
285
241
277
484
520
467
503
Cv
0.9
1.0
1.8
2.1
2.7
3.7
Note) Values without bracket
Application Example
(1) Blow-off valve
(2) Pressure release valve
X
(3) Selector valve
(P)1
(P)1
2(A)
External pilot
Vacuum releasing air
Atmospheric pressure
or micro pressure
External pilot
Tank
(7) Double-acting
cylinder drive
(8) Double-acting
cylinder drive
(Exhaust center)
N.C.
2(A)
(P)1
(P)1
(R)3
(A)
2
N.O.
2(A)
2(A)
2(A)
1
(P)
(R)3
Tank
2(A) Vacuum pad
(R)3
External pilot
(6) Single-acting
cylinder drive
X
Vacuum pump (P)1
2(A)
P2 (R)3
External pilot
(5) Divider valve
X
P1 (P)1
2(A)
X
(R)3
(R)3
(4) Valve for vacuum
X
X
3
(R)
1
(P)
3
(R)
1
(P)
2(A)
3
(R)
1
(P)
External pilot
Construction
Body ported
i
Symbol
Pilot type
N.C.
w r y
t q ue
N.O.
2(A)
2(A)
(P)1 3(R)
(P)1 3(R)
2(A)
Internal pilot
2(A)
External pilot
(P)1 3(R)
X
Bracket Assembly Part No.
Component Parts
No.
Description
1(P)
Strainer
Material
Note
Aluminum die-casted
White
1
Body
2
Adapter plate
Resin
Gray
3
End plate
Resin
White
4
Piston
Resin
5
Poppet valve
6
Retainer
7
Spring
Description
Bracket
(With 2 screws)
Model
Part no.
VP342
VP300-227-1A
VP542
VP500-227-1A
VP742
VP700-227-1A
Aluminum/HNBR
Resin
Stainless steel
Replacement Parts
No.
Description
Part no.
Note
8
Pilot valve assembly
Refer to “How to Order Pilot Valve Assembly” on page 1837.
Built-in strainer
1836
3(R)
3
(R)
Pilot Poppet Type
Body Ported/Single Unit
Series VP300/500/700
How to Order Pilot Valve Assembly
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.
Valve model:
VP
∗ Select from the below in accordance with the valve used.
5 G Z  1 
 Grommet or L/M-type
V2 11
5 G Z
Light/Surge voltage suppressor
Nil
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
S
Z
R
U
V211
Pilot valve assembly
DC
AC
Note)
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to page 1862 for
details.
Electrical entry
G
H
L
LN
LO
M
MN
MO
Grommet (Lead wire length 300 mm)
Grommet (Lead wire length 600 mm)
With lead wire
L-type plug
Without lead wire
connector
Without connector
With lead wire
M-type plug
Without lead wire
connector
Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to page 1859 when different length of lead
wire for L/M-type plug connector is required.
 DIN or Conduit type
DIN connector
(Refer to page 1860.)
V2 12
Pressure specification
Nil
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Coil specification
Nil
T
Standard
With power saving circuit (DC only)
∗ T type is only available for DC mode.
V212
Pilot valve assembly
5
Rated voltage
SYJ
DC
5 24 VDC
6 12 VDC
VQZ
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
VP
VG
VP3
Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
1837
Series VP300/500/700
Series VP300/Body Ported/Dimensions
Grommet (G)
1/8, 1/4
2(A) port
26.2
11
2 x ø3.2
(For mounting)
M5 x 0.8
External pilot port
(External pilot specification: R)
NC
21.5
X
Manual override
3.4
0.8
1.3
2A
20.4 16
57.6
Approx. 300
(Lead wire length)
(1.6)
96.1
(9)
Grommet (G)
(Indicator light)
35
25
31
42.7
(45)
15
(54.5)
26.2
14
2.8
(17.5)
19.7
(35)
– +
42.7
(5.4)
2 x ø3.2
(For mounting)
(20.9)
(Dista
nc
4.5
e betw
een p
orts)
1/8, 1/4
1(P), 3(R) port
Approx. 300
(Lead wire length)
DC without light/surge voltage suppressor
(Mounting groove
for M5 thread)
97.3
26.5
NO
1P
1.1
3R
20.4 16
ø3.8
PE port∗
56.4
∗ Refer to page 1857 separately when piping to
PE port is required.
Pg9
Max. 10
86.9 [76.9]
76.9 [66.9]
105.3
Pg9
Applicable cable O.D.
ø4.5 to ø7
102.9
94
Approx. 300
(Lead wire length)
Max. 10
82.7
73.7
53.7
102.4
Conduit terminal (T)
DIN terminal (D, Y)
Applicable cable O.D.
ø4.5 to ø7
88.9
42.7
20
M-type
plug connector (M)
Approx. 300
(Lead wire length)
L-type
plug connector (L)
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1838
Pilot Poppet Type
Body Ported/Single Unit
Series VP300/500/700
Series VP500/Body Ported/Dimensions
Grommet (G)
1/4, 3/8
2(A) port
41.1
19
1/8
External pilot port
(External pilot specification: R)
NC
26
2 x ø4.2
(For mounting)
X
25.6
Approx. 300
(Lead wire length)
3.5
31
83.8
4.5
1.3
2A
Manual override
(1.6)
(9)
122.3
Grommet (G)
(Indicator light)
DC without light/surge voltage suppressor
45
40
45
22
(22.5)
16.3
(50)
23.5
(60)
4
(45)
– +
31.5
(5.4)
2 x ø4.2
(For mounting)
39.6
Approx. 300
(Lead wire length)
(Mounting groove
for M5 thread)
(31.5)
(Dista
nce b
etwee
n port
s)
1/4, 3/8
1(P), 3(R) port
123.5
32
2.5
7
3R
NO
1P
ø3.8
PE port∗
30.7
25.6
83.6
∗ Refer to page 1857 separately when piping to
PE port is required.
Conduit terminal (T)
Approx. 300
(Lead wire length)
Pg9
Max. 10
85
76
Applicable cable O.D.
ø4.5 to ø7
89.2 [79.2]
Max. 10
DIN terminal (D, Y)
Applicable cable O.D.
ø4.5 to ø7
56
79.2 [69.2]
Pg9
SYJ
VQZ
VP
131.5
129.1
120.2
115.1
VG
128.6
45
22.3
M-type
plug connector (M)
Approx. 300
(Lead wire length)
L-type
plug connector (L)
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1839
VP3
Series VP300/500/700
Series VP700/Body Ported/Dimensions
Grommet (G)
1.3
33
NC
X
2A
1/8
External pilot port
(External pilot specification: R)
7.5
27.5
2 x ø5.2
(For mounting)
4.5
51.5
3/8, 1/2
2(A) port
Manual override
41
31
(2)
106.8
Approx. 300
(Lead wire length)
(9)
145.3
Grommet (G)
38.5
31
51.5
(74)
(43)
ce betw
een po
(Distan
30.5
146.5
42
2.5
40
3R
9
rts)
1P
NO
3/8, 1/2
1(P), 3(R) port
34.3
9.4
(60)
56.5
63
40
(31.5)
(Mounting
groove for
M6 thread)
Approx. 300
(Lead wire length)
– +
63
(6.4)
(Indicator light)
(63)
DC without light/surge voltage suppressor
2 x ø5.2
(For mounting)
ø4
PE port∗
107.5
∗ Refer to page 1857 separately when piping to
PE port is required.
Pg9
Max. 10
Pg9
107.2 [97.2]
97.2 [87.2]
152.1
151.6
Approx. 300
(Lead wire length)
Applicable cable O.D.
ø4.5 to ø7
154.5
103
Max. 10
Applicable cable O.D.
ø4.5 to ø7
94
74
Conduit terminal (T)
DIN terminal (D, Y)
143.2
40.3
138.1
63
M-type
plug connector (M)
Approx. 300
(Lead wire
length)
L-type
plug connector (L)
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1840
Rubber Seal
3 Port/Pilot Poppet Type
Base Mounted/Single Unit
Series VP300/500/700
Note) Only DIN and conduit terminal types
are available for AC mode.
Refer to the electrical entry for details.
How to Order
VP 3 4 4
Base mounted
5 G
A
1
Series
3
5
7
Pilot type
VP300
VP500
VP700
Nil
R
Type of actuation
Internal pilot
External pilot
A N.C. (Normally closed)
B N.O. (Normally open)
Pressure specification
Nil
K
Thread type
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Nil
F
N
T
Coil specification
Nil
Standard
With power saving circuit (DC only)
T
Note) Be sure to select the power saving
circuit type when it is continuously
energized for a long time.
(Refer to page 1861 for details.)
∗ T type is only available for DC mode.
When T is selected, only Z type of
light/surge voltage suppressor is
available.
(Note that when the electrical entry of
DIN terminal type without connector is
selected, only DOS and YOS are
available.)
Rated voltage
Made to Order
Nil
DC
5 24 VDC
6 12 VDC
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
X500
Pilot exhaust port with piping thread
(M3) specification (Refer to page 1857).
X600
Triac output specification (Refer to page 1857).
Port size (Sub-plate)
Symbol
Nil
01
02
03
04
Electrical entry
Grommet
Rc
G
NPT
NPTF
Port size VP300 VP500
Without sub-plate∗
1/8
1/4
3/8
1/2
VP700
∗ With a gasket and two mounting bolts.
L-type plug
connector
M-type plug
connector
DIN
Conduit
(EN175301-803)
terminal
terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
DIN
terminal
Manual override
Nil: Non-locking
push type
D: Push-turn locking
E: Push-turn locking
slotted type
lever type
G: Lead wire
L: With lead wire M: With lead wire
length 300 mm (length 300 mm) (length 300 mm)
SYJ
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal
LN:
Without lead wire Without lead wire
G: Lead wire
—
—
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
DC
AC
Note)
MO:
DO:
YO:
Without connector
Without connector
Without connector
—
VQZ
VP
VG
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the connector,
DOZ, DOU, YOZ, YOU are not available.
length 300 mm
H: Lead wire
CE DC
compliant AC Note)
Nil
S
Z
R
U
MN:
length 600 mm
DC
Without light/
surge voltage LO:
suppressor
Without connector
Light/Surge voltage suppressor
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to page 1862 for
details.
∗ LN and MN types are with 2 sockets.
∗ Refer to page 1859 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to page 1860 for details on the DIN (EN175301-803) terminal.
Note) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking
compliant.
1841
VP3
Series VP300/500/700
Low power consumption 1.5 W (DC)
Possible to use as either a
selector or divider valve
Possible to change from
N.C. to N.O.
• Refer to page 1862 for
changing the type of actuation.
Possible to use in vacuum
applications
Up to –100 kPa
Specifications
Fluid
Type of actuation
Standard
Internal pilot
Operating pressure range (MPa) High-pressure type
Standard
External pilot
High-pressure type
Operating pressure range (MPa)
Pilot pressure range
Ambient and fluid temperature (°C)
Max. operating frequency (Hz)
Manual override
Series VP300
Pilot exhaust type
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s2) Note)
Enclosure
Air
N.C. or N.O. (Convertible)
0.2 to 0.7
0.2 to 1.0
–100 kPa to 0.7
–100 kPa to 1.0
Same as operating pressure (Min. 0.2 MPa)
–10 to 50 (No freezing)
5
Non-locking push type
Push-turn locking slotted type
Push-turn locking lever type
Individual exhaust
Not required
Unrestricted
300/50
Dust-tight (IP65 for D, Y, T)
Note) Impact resistance:
Series VP500
No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
Solenoid Specifications
Electrical entry
DC
AC (50/60 Hz)
Allowable voltage fluctuation
Standard
Power consumption (W) DC
Coil rated voltage (V)
Series VP700
External Pilot
Use external pilot type in the following
cases:
• For vacuum or for low pressure 0.2 MPa or
less
• Please consult with SMC for use in a
vacuum hold application.
• When having P port downsized in diameter
• When using A port as the atmospheric
releasing port, e.g. air blower
• If manifold, external pilot piping can be
centralized in manifold base.
Made to Order
(Refer to page 1857 for details.)
X500
Pilot exhaust port with piping
thread (M3) specification
X600
Triac output specification
With power saving circuit
24 V
100 V
110 V
[115 V]
Apparent power (VA)∗ AC
200 V
220 V
[230 V]
240 V
Surge voltage suppressor
Indicator light
DIN terminal (D)
Grommet (G), (H)
DIN (EN175301-803) terminal (Y)
L-type plug connector (L)
Conduit terminal (T)
M-type plug connector (M)
G, H, L, M
D, Y, T
24, 12
24, 100, 110, 200, 220, 240
±10% of rated voltage∗
1.5 (With light: 1.55)
0.55 (With light only)
1.5 (With light: 1.55)
1.5 (With light: 1.75)
0.75 (With light only)
1.5 (With light: 1.75)
1.55 (With light: 1.65)
1.55 (With light: 1.7)
Diode (Non-polar type: Varistor)
LED (Neon bulb is used for AC mode of D, Y, T.)
∗ It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
∗ Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
∗ Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the allowable
voltage fluctuation should be within the following range.
24 VDC: –7% to +10%
12 VDC: –4% to +10%
Response Time
Model
VP344
VP544
VP744
Response time ms (at 0.5 MPa)
Pressure specifications Without light/surge With light/surge voltage suppressor
voltage suppressor
S, Z type
R, U type
Standard (0.2 to 0.7)
13 or less
38 or less
16 or less
High-pressure type (0.2 to 1.0)
17 or less
42 or less
20 or less
Standard (0.2 to 0.7)
14 or less
39 or less
17 or less
High-pressure type (0.2 to 1.0)
18 or less
43 or less
21 or less
Standard (0.2 to 0.7)
19 or less
44 or less
22 or less
High-pressure type (0.2 to 1.0)
22 or less
47 or less
25 or less
AC
38 or less
42 or less
39 or less
43 or less
44 or less
47 or less
Note) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated voltage)
1842
Pilot Poppet Type
Base Mounted/Single Unit
Series VP300/500/700
Flow Characteristics/Weight
Model
Port size
C [dm3/(s·bar)]
3.6
3.9
7.5
8.8
12.9
14.7
1/8
1/4
1/4
3/8
3/8
1/2
VP344
VP544
VP744
1 ↔ 2 (P ↔ A)
b
0.22
0.22
0.16
0.07
0.10
0.05
Cv
0.8
0.9
1.7
2.0
2.9
3.3
2 ↔ 3 (A ↔ R)
b
0.24
0.14
0.20
0.13
0.24
0.17
C [dm3/(s·bar)]
3.5
3.8
7.3
8.8
13.3
15.0
Weight (g) Note)
Grommet
DIN terminal
216 (149)
252 (185)
211 (149)
247 (185)
370 (245)
406 (281)
362 (245)
398 (281)
676 (459)
712 (495)
658 (459)
694 (495)
Cv
0.8
0.9
1.7
2.0
3.1
3.4
Note) ( ): Values without sub-plate
Application Example
(1) Blow-off valve
(2) Pressure release valve
X
(3) Selector valve
(P)1
(P)1
2(A)
(R)3
Tank
(7) Double-acting
cylinder drive
(P)1
Tank
(R)3
1
(P)
(R)3
(8) Double-acting
cylinder drive
(Exhaust center)
N.O.
2(A)
(A)
2
Vacuum pad
Vacuum releasing air
Atmospheric pressure
External pilot
or micro pressure
N.C.
2(A)
(P)1
2(A)
(R)3
External pilot
(6) Single-acting
cylinder drive
X
Vacuum pump (P)1
2(A)
P2 (R)3
External pilot
(5) Divider valve
X
P1 (P)1
2(A)
X
(R)3
External pilot
(4) Valve for vacuum
X
X
2(A)
3
(R)
1
(P)
2(A)
3
(R)
1
(P)
2(A)
3
(R)
1
(P)
3
(R)
External pilot
Construction
Base mounted
i
Symbol
Pilot type
N.C.
w r y
t q ue
N.O.
2(A)
2(A)
(P)1 3(R)
(P)1 3(R)
Internal
pilot
External
pilot
2(A)
2(A)
(P)1 3(R)
(P)1 3(R)
2(A)
X
!0
Strainer
X
X
Component Parts
No.
Description
Material
Note
1
Body
Aluminum die-casted
White
2
Adapter plate
Resin
Gray
3
End plate
Resin
White
4
Piston
Resin
5
Poppet valve
6
Retainer
7
Spring
VG
VP 3 00 202 1
Resin
Series
Stainless steel
3
5
7
Part no.
9
Note
VP744
VP544
Pilot valve assembly Refer to “How to Order Pilot Valve Assembly” on page 1844. Built-in strainer
HNBR
Gasket
VP700-217-1
VP300-217-1
VP500-217-1
10
Sub-plate
VP300-202-
VP500-202-
VP700-202-
—
Hexagon socket
head bolt (1 pc.)
VP300-224-1
(M3 x 36)
VP500-224-1
(M4 x 46)
VP700-224-1
For valve mounting
(M5 x 66)
8
Description
VP
How to Order Sub-plate
Aluminum/HNBR
VP344
Aluminum die-casted
Caution
Tightening Torque
of Mounting Screw
M3: 0.8 N·m
M4: 1.4 N·m
M5: 2.9 N·m
VP344
VP544
VP744
Port size
SYJ
VQZ
1(P)
Replacement Parts
No.
o
3(R)
VP3
Thread type
Nil
F
N
T
Rc
G
NPT
NPTF
Symbol VP344 VP544 VP744
1/8
1/4
3/8
1
1/4
3/8
1/2
2
Note) Internal/external pilot common specifications
1843
Series VP300/500/700
How to Order Pilot Valve Assembly
Caution
When only the pilot valve assembly is replaced, it is not possible to change from V211 (Grommet or L/M-type) to V212 (DIN or Conduit
type), or vice versa.
Valve model:
VP
∗ Select from the below in accordance with the valve used.
5 G Z 1   
 Grommet or L/M-type
V2 11
5 G Z
Light/Surge voltage suppressor
Nil
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
S
Z
R
U
V211
Pilot valve assembly
DC
AC
Note)
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation. When T is selected, only Z type of
light/surge voltage suppressor is available.
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to page 1862 for
details.
Electrical entry
G
H
L
LN
LO
M
MN
MO
 DIN or Conduit type
DIN connector
(Refer to page 1860.)
V2 12
Pressure specification
Nil
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Coil specification
Nil
T
Standard
With power saving circuit (DC only)
∗ T type is only available for DC mode.
V212
Pilot valve assembly
5
Grommet (Lead wire length 300 mm)
Grommet (Lead wire length 600 mm)
With lead wire
L-type plug
Without lead wire
connector
Without connector
With lead wire
M-type plug
Without lead wire
connector
Without connector
∗ LN and MN types are with 2 sockets.
∗ Refer to page 1859 when different length of
lead wire for L/M-type plug connector is
required.
Rated voltage
DC
5 24 VDC
6 12 VDC
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
Caution
For V212 (DIN or Conduit type), the coil specification and voltage (including light/surge voltage suppressor) cannot be changed by
changing the pilot valve assembly.
Caution
Tightening torque of the pilot valve assembly mounting screw
M2.5: 0.32 N·m
1844
Pilot Poppet Type
Base Mounted/Single Unit
Series VP300/500/700
Series VP300/Base Mounted/Dimensions
Grommet (G)
1/8, 1/4
2(A) port
12
19.5
43.7
30
11.2
DC without light/surge voltage suppressor
1P
12
6.7
(Indicator light)
18.5
57.6
66.7
96.1
38
M5 x 0.8
External pilot port
19.5
34
97.3
24
12
X
X
PE port∗
(ø3.8)
17.5
59
66.7
Approx. 300
(Lead wire length)
Approx. 300
(Lead wire length)
3R
NC
1.3
NC
Grommet (G)
43
2A
– +
Manual override
1/8, 1/4
3(R) port
35
2 x ø4.2
(For mounting)
NO
18.5
1/8, 1/4
1(P) port
39
∗ Refer to page 1857 separately when piping to
PE port is required.
Conduit terminal (T)
Applicable cable O.D.
ø4.5 to ø7
106.7
97.7
77.7
Approx. 300
(Lead wire length)
Pg9
Applicable cable O.D.
ø4.5 to ø7
110.9 [100.9]
Max. 10
44
DIN terminal (D, Y)
Max. 10
66.7
M-type
plug connector (M)
Approx. 300
(Lead wire length)
L-type
plug connector (L)
100.9 [90.9]
Pg9
SYJ
VQZ
VP
105.3
102.9
94
88.9
X
X
X
X
102.4
VG
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1845
VP3
Series VP300/500/700
Series VP500/Base Mounted/Dimensions
17.6
1/4, 3/8
3(R) port
2A
DC without light/surge voltage suppressor
3R
1.3
NC
– +
NC
Manual override
1P
13.5
12.6
83.8
Approx. 300
(Lead wire length)
Grommet (G)
Approx. 300
(Lead wire length)
47
52
2 x ø5.2
(For mounting)
23
NO
50.5
28.5
42
1/4, 3/8
2(A) port
13.5
Grommet (G)
73.5
23
122.3
44.8
28.5
1/8
(External pilot port)
123.5
28.5
13.5
X
X
PE port∗
(ø3.8)
19.5
73.5
(Indicator light)
49.7
57
1/4, 3/8
1(P) port
∗ Refer to page 1857 separately when piping to
PE port is required.
Pg9
X
129.1
Pg9
X
X
X
120.2
Approx. 300
(Lead wire length)
117.7 [107.7]
107.7 [97.7]
Max. 10
Applicable cable O.D.
ø4.5 to ø7
Max. 10
113.5
104.5
84.5
128.6
Conduit terminal (T)
131.5
DIN terminal (D, Y)
Applicable cable O.D.
ø4.5 to ø7
115.1
73.5
50.8
M-type
plug connector (M)
Approx. 300
(Lead wire
length)
L-type
plug connector (L)
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1846
Pilot Poppet Type
Base Mounted/Single Unit
Series VP300/500/700
Series VP700/Base Mounted/Dimensions
Grommet (G)
3/8, 1/2
2(A) port
16
40
18
NC
DC without light/surge voltage
suppressor
1P
16
24
11.5
106.8
145.3
95.5
66.8
PE port∗
(ø4)
1/8
(External pilot port)
3/8, 1/2
1(P) port
16
21
32.5
X
146.5
95.5
Approx. 300
(Lead wire length)
Grommet (G)
3R
1.3
– +
Manual override
(Indicator light)
3/8, 1/2
3(R) port
NO
NC
2A
Approx. 300
(Lead wire length)
67
2 x ø6.2
(For mounting)
53
66
72.5
24
X
40
64
80
∗ Refer to page 1857 separately when piping to
PE port is required.
DIN terminal (D, Y)
Conduit terminal (T)
Applicable cable O.D.
ø4.5 to ø7
106.5
Pg9
Approx. 300
(Lead wire length)
139.7 [129.7]
129.7 [119.7]
Pg9
Max. 10
135.5
126.5
Applicable cable O.D.
ø4.5 to ø7
Max. 10
95.5
72.8
M-type
plug connector (M)
Approx. 300
(Lead wire length)
L-type
plug connector (L)
SYJ
VQZ
VP
154.5
152.1
143.2
138.1
X
X
X
X
151.6
VG
(Indicator light)
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1847
VP3
Rubber Seal/3 Port/Pilot Poppet Type Manifold
Common Exhaust Type 41 /
Individual Exhaust Type 42
Series VP300/500/700
How to Order Manifold
Type 41/Common exhaust
VV3P 3 41
04 1 02
Series
3
5
7
Thread type
VP300
VP500
VP700
Nil
F
N
T
Pilot type
Nil
R
Port size
Internal pilot
External pilot
Note) When the external
pilot type manifold is
selected, external
pilot type valves are
mounted.
Symbol
02
03
04
···
20
20 stations
04 3 02
Series
3
5
7
Thread type
VP300
VP500
VP700
Nil
F
N
T
Pilot type
Nil
R
Rc
G
NPT
NPTF
Port size
Internal pilot
External pilot
Note) When the external
pilot type manifold is
selected, external
pilot type valves are
mounted.
Symbol
02
03
04
Stations
02
2 stations
···
···
1848
Applicable series
VP300
VP500
VP700
2 stations
···
VV3P 3 42
Port size
1/4
3/8
1/2
Stations
02
Type 42/Individual exhaust
Rc
G
NPT
NPTF
20
20 stations
Port size
1/4
3/8
1/2
Applicable series
VP300
VP500
VP700
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42
Series VP300/500/700
Note) Only DIN and conduit
terminal types are
available for AC mode.
Refer to the electrical
entry for details.
How to Order Valve (With a gasket and two mounting bolts)
VP 3 4 4
5 G
1 A
Series
3
5
7
Type of actuation
VP300
VP500
VP700
A N.C. (Normally closed)
B N.O. (Normally open)
Manual override
Pilot type
Nil
R
D: Push-turn locking
Nil: Non-locking
push type
Internal pilot
External pilot
E: Push-turn locking
slotted type
lever type
Pressure specification
Nil
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Coil specification
Nil
T
Light/Surge voltage suppressor
Standard
With power saving circuit (DC only)
Nil
S
Z
R
U
Note) Be sure to select the power saving circuit
type when it is continuously energized for a
long time. (Refer to page 1861 for details.)
∗ T type is only available for DC mode. When T is
selected, only Z type of light/surge voltage
suppressor is available.
(Note that when the electrical entry of DIN
terminal type without connector is selected, only
DOS and YOS are available.)
DC
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
AC
Note)
Note) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
∗ In the DIN terminal type, since a light is installed in the connector,
DOZ, DOU, YOZ, YOU are not available.
Rated voltage
DC
5 24 VDC
6 12 VDC
Caution
When using the surge voltage suppressor type,
residual voltage will remain. Refer to page 1862 for
details.
Made to Order
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
B 24 VAC
Nil
X500
Electrical entry
Grommet
L-type plug
connector
—
Pilot exhaust port with piping thread (M3)
specification (Refer to page 1857).
X600 Triac output specification (Refer to page 1857).
M-type plug
connector
DIN
Conduit
(EN175301-803)
terminal
terminal
[IP65 compatible] [IP65 compatible] [IP65 compatible]
DIN
terminal
G: Lead wire
SYJ
L: With lead wire M: With lead wire
length 300 mm (length 300 mm) (length 300 mm)
H: Lead wire
length 600 mm
D: With connector Y: With connector T: Conduit
terminal
MN:
Without lead wire Without lead wire
VP3
G: Lead wire
length 300 mm
H: Lead wire
length 600 mm
DC
Without light/
surge voltage LO:
suppressor
Without connector
—
VP
VG
LN:
DC
CE
compliant AC Note)
VQZ
—
MO:
DO:
YO:
Without connector
Without connector
Without connector
—
∗ LN and MN types are with 2 sockets.
∗ Refer to page 1859 when different length of lead wire for L/M-type plug connector is required.
∗ Refer to page 1860 for details on the DIN (EN175301-803) terminal.
Note) With the same specifications as the DC type, all lead wire entries for the 24 VAC type are CE marking compliant.
1849
Series VP300/500/700
Manifold Specifications
Piping is concentrated on
the base side.
All external pilots are
gathered in the base.
Piping specifications
Series
Common external pilot port allows one
piping.
VP300
2 types of exhaust ports
Common or individual exhaust type are
available. For individual exhaust type,
exhaust can be restricted.
VP500
Easy to change between
N.C. and N.O.
VP700
Type of actuation can be easily changed
from normally closed to normally open by
changing the direction of a valve and
end-plate only 180°.
Base model 1P (SUP) 3R (EXH)
port type port type
VV3P3-41
Common
VV3P3-42
Individual
VV3P5-41
VV3P5-42
Common
Common
Individual
VV3P7-41
Common
VV3P7-42
Individual
Port size
Applicable Applicable
valve
stations Note)
Manifold base
Weight: W [g]
Stations: n
1/4
VP344
2 to 20 stations W = 110n + 90
3/8
VP544
2 to 20 stations W = 190n + 150
1/2
VP744
2 to 20 stations W = 410n + 380
Note) Supply pressure to 1(P) ports and exhaust pressure from 3(R) ports on both sides for 10 stations
or more.
• Refer to page 1862 for
changing the type of actuation.
Manifold Option
Description
Blanking plate assembly
(With a gasket and two
mounting bolts)
Part no.
Applicable manifold base model
VP300-25-1A
VV3P3
VP500-25-1A
VV3P5
VP700-25-1A
VV3P7
VV3P3-41-051-02
VV3P5-42-053-03
How to Order Manifold Assembly (Example)
Ordering example (VV3P3-41)
VP344-5GZ1-B
VP344-5GZ1-A
VP300-25-1A
Us
ide
Sta
VV3P3-41-051-02 ···················· 1 set (Type 41, 5-station manifold base part no.)
∗ VP300-25-1A ······················· 1 set (Blanking plate assembly part no.)
∗ VP344-5GZ1-A ···················· 2 sets (N.C. type part no.)
∗ VP344-5GZ1-B ···················· 2 sets (N.O. type part no.)
tio
ns
3
2
The asterisk denotes the symbol for assembly.
Prefix it to the part nos. of the solenoid valve, etc.
1
Ds
ide
1850
Port size: 1/4
• Indicate the valves to be attached below the manifold part number, in order starting
from station 1 as shown in the drawing.
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42
Series VP300/500/700
Series VP300/Dimensions
Approx. 300
(Lead wire length)
Type 41/Common exhaust: VV3P3-41- Stations 1-02
Grommet (G)
M5 x 0.8
Common external pilot port
(External pilot specification: R)
NO
(Pitch)
P = 27.5
13.5
1/4
1(P), 3(R) port
PE port∗
(ø3.8)
28
L2
L1
(Station n)
27
50
3R
NC
26.2
2 x ø6.5
(For mounting)
1P
96.1
57.6
26.2
Manual override
72.5
30.5
24
17.5
N.C.
57.6
96.1
N.O.
7.5
∗ Refer to page 1857 separately when piping
to PE port is required.
Grommet (G)
DC without light/surge voltage
suppressor
(Station 1)
(Indicator light)
Station n 2 stations 3
L1 83.5 111
L2 68.5 96
(Pitch)
P = 27.5
1P
97.3
2A
28
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19 20 stations
138.5
123.5
166
151
193.5
178.5
221
206
248.5
233.5
276
261
303.5
288.5
331
316
358.5
343.5
386
371
413.5
398.5
441
426
468.5
453.5
496
481
523.5
508.5
551
536
L-type
plug connector (L)
M-type
plug connector (M)
Approx. 300
(Lead wire length)
1/4
2(A) port
11
37.5
50.1
57.2
80.2
2A
3R
– +
578.5
563.5
DIN terminal (D, Y)
51.5
80.2
Conduit terminal (T)
SYJ
VQZ
VG
105.3
102.9
VP
1P
3R
1P
3R
1P
94
88.9
3R
1P
102.4
3R
(Indicator light)
111.2
120.2
Applicable cable O.D.
ø4.5 to ø7
Pg9
Max. 10
57.5
80.2
Pg9
91.2
Max. 10
Approx. 300
(Lead wire length)
VP3
Approx. 300
(Lead wire
length)
114.4 [104.4]
124.4 [114.4]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1851
Series VP300/500/700
Series VP300/Dimensions
Type 42/Individual exhaust: VV3P3-42- Stations 3-02
Grommet (G)
(Pitch)
P = 27.5
3R
Approx. 300
(Lead wire length)
18.5
28
3R
1/4
3(R) port
– +
M5 x 0.8
Common external pilot port
(External pilot specification: R)
N.O.
N.C.
72.5
30.5
NO
(Pitch)
P = 27.5
(Station n)
7.5
50
13.5
28
L2
L1
17.5
24
1P
NC
26.2
2 x ø6.5
(For mounting)
57.6
96.1
96.1
57.6
26.2
Manual override
1/4
1(P) port
Grommet (G)
PE port∗
(ø3.8)
DC without light/surge voltage
suppressor
∗ Refer to page 1857 separately when piping
to PE port is required.
(Station 1)
97.3
1P
(Indicator light)
Station n 2 stations 3
L1 83.5 111
L2 68.5 96
2A
(Pitch)
P = 27.5
28
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19 20 stations
138.5
123.5
166
151
193.5
178.5
221
206
248.5
233.5
276
261
303.5
288.5
331
316
358.5
343.5
386
371
413.5
398.5
441
426
468.5
453.5
496
481
523.5
508.5
551
536
L-type
plug connector (L)
M-type
plug connector (M)
578.5
563.5
DIN terminal (D, Y)
Approx. 300
(Lead wire length)
2A
1/4
2(A) port
11
37.5
50.1
57.2
80.2
– +
51.5
80.2
Conduit terminal (T)
Pg9
91.2
1P
105.3
102.9
1P
1P
94
88.9
Approx. 300
(Lead wire
length)
111.2
120.2
Applicable cable O.D.
ø4.5 to ø7
Pg9
Max. 10
57.5
80.2
Max. 10
Approx. 300
(Lead wire length)
102.4
1P
(Indicator light)
114.4 [104.4]
124.4 [114.4]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1852
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42
Series VP300/500/700
Series VP500/Dimensions
M5 x 0.8
Common external pilot port
(External pilot specification: R)
N.C.
Manual override
42
30
20.5
NO
3R
41.1
83.8
122.3
NC
1P
122.3
83.8
41.1
2 x ø7.2
(For mounting)
23.5
N.O.
33
60
Approx. 300
(Lead wire length)
Type 41/Common exhaust: VV3P5-41- Stations 1-03
Grommet (G)
3/8
1(P), 3(R) port
(Pitch)
P = 33
PE port∗
(ø3.8)
31
L2
L1
(Station n)
7.5
∗ Refer to page 1857 separately when piping
to PE port is required.
Grommet (G)
DC without light/surge voltage
suppressor
(Station 1)
(Indicator light)
(Pitch)
P = 33
Station n 2 stations 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 95 128 161 194 227 260 293 326 359 392 425 458 491 524 557 590 623 656 689
L2 80 113 146 179 212 245 278 311 344 377 410 443 476 509 542 575 608 641 674
L-type
plug connector (L)
1P
123.5
47.5
61.3
69.5
92.5
31
M-type
plug connector (M)
DIN terminal (D, Y)
Approx. 300
(Lead wire length)
3/8
2(A) port
2A
13.5
2A
3R
– +
63.8
92.5
Conduit terminal (T)
SYJ
VQZ
(Indicator light)
3R
131.5
123.5
132.5
Applicable cable O.D.
ø4.5 to ø7
VP3
Pg9
Max. 10
Pg9
103.5
VG
1P
3R
129.1
1P
3R
Approx. 300
(Lead wire
length)
1P
120.2
115.1
1P
69.8
92.5
Max. 10
Approx. 300
(Lead wire length)
128.6
3R
VP
126.7 [116.7]
136.7 [126.7]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1853
Series VP300/500/700
Series VP500/Dimensions
Type 42/Individual exhaust: VV3P5-42- Stations 3-03
Grommet (G)
(Pitch)
P = 33 31
28.5
3/8
3(R) port
3R
Approx. 300
(Lead wire length)
3R
– +
M5 x 0.8
Common external pilot port
(External pilot specification: R)
Manual override
42
30
NO
1P
16.5
41.1
83.8
122.3
NC
122.3
83.8
41.1
2 x ø7.2
(For mounting)
60
N.C.
23.5
N.O.
3/8
1(P) port
(Pitch)
P = 33
31
L2
L1
(Station n)
Grommet (G)
DC without light/surge voltage
suppressor
PE port∗
(ø3.8)
7.5
∗ Refer to page 1857 separately when piping
to PE port is required.
(Station 1)
(Pitch)
P = 33
123.5
31
Station n 2 stations 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 95 128 161 194 227 260 293 326 359 392 425 458 491 524 557 590 623 656 689
L2 80 113 146 179 212 245 278 311 344 377 410 443 476 509 542 575 608 641 674
L-type
plug connector (L)
M-type
plug connector (M)
DIN terminal (D, Y)
Approx. 300
(Lead wire length)
2A
13.5
3/8
2(A) port
47.5
61.3
69.5
92.5
– +
2A
1P
(Indicator light)
63.8
92.5
Conduit terminal (T)
131.5
1P
1P
129.1
Pg9
103.5
123.5
132.5
Applicable cable O.D.
ø4.5 to ø7
Pg9
Max. 10
Approx. 300
(Lead wire
length)
1P
120.2
115.1
1P
69.8
92.5
Max. 10
Approx. 300
(Lead wire length)
128.6
(Indicator light)
126.7 [116.7]
136.7 [126.7]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1854
Pilot Poppet Type
Common Exhaust Type 41 /Individual Exhaust Type 42
Series VP300/500/700
Series VP700/Dimensions
Approx. 300
(Lead wire length)
Type 41/Common exhaust: VV3P7-41- Stations 1-04
Grommet (G)
1/8
Common external pilot port
(External pilot specification: R)
N.O. N.C.
Manual override
55
40
24
2 x ø8.5
(For mounting)
32
48
86
3R
1P
145.3
106.8
51.5
51.5
106.8
145.3
NC
NO
1/2
1(P), 3(R) port
(Pitch)
P = 41
37
L2
L1
(Station n)
PE port∗
(ø4)
8
∗ Refer to page 1857 separately when piping
to PE port is required.
(Station 1)
(Indicator light)
Grommet (G)
DC without light/surge voltage
suppressor
(Pitch)
P = 41
3R
37
Station n 2 stations 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 115 156 197 238 279 320 361 402 443 484 525 566 607 648 689 730 771 812 853
L2 99 140 181 222 263 304 345 386 427 468 509 550 591 632 673 714 755 796 837
L-type
plug connector (L)
M-type
plug connector (M)
DIN terminal (D, Y)
97.3
126
Approx. 300
(Lead wire length)
1/2
2(A) port
1P
146.5
2A
19
2A
63
78.2
103
126
– +
Conduit terminal (T)
SYJ
(Indicator light)
VQZ
157
166
Applicable cable O.D.
ø4.5 to ø7
3R
154.5
VG
VP3
Pg9
Max. 10
Pg9
137
1P
3R
1P
152.1
3R
Approx. 300
(Lead wire
length)
1P
143.2
138.1
1P
103.3
126
Max. 10
Approx. 300
(Lead wire length)
151.6
3R
VP
160.2 [150.2]
170.2 [160.2]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1855
Series VP300/500/700
Series VP700/Dimensions
Type 42/Individual exhaust: VV3P7-42- Stations 3-04
Grommet (G)
(Pitch)
P = 41
37
34
1/2
3(R) port
– +
N.C.
55
40
Manual override
2 x ø8.5
(For mounting)
1P
145.3
106.8
51.5
51.5
106.8
145.3
NC
1/2
1(P) port
NO
(Pitch)
P = 41
Grommet (G)
PE port∗
(ø4)
37
L2
L1
(Station n)
86
N.O.
24 32
Approx. 300
(Lead wire length)
3R
3R
1/8
Common external pilot port
(External pilot specification: R)
8
∗ Refer to page 1857 separately when piping
to PE port is required.
DC without light/surge voltage
suppressor
(Station 1)
(Indicator light)
1P
63
78.2
103
126
2A
19
2A
146.5
– +
(Pitch)
P = 41
37
Station n 2 stations 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 stations
L1 115 156 197 238 279 320 361 402 443 484 525 566 607 648 689 730 771 812 853
L2 99 140 181 222 263 304 345 386 427 468 509 550 591 632 673 714 755 796 837
L-type
plug connector (L)
M-type
plug connector (M)
DIN terminal (D, Y)
97.3
126
Approx. 300
(Lead wire length)
1/2
2(A) port
Conduit terminal (T)
Pg9
157
166
Applicable cable O.D.
ø4.5 to ø7
1P
154.5
1P
152.1
137
Pg9
Max. 10
Approx. 300
(Lead wire
length)
1P
143.2
138.1
1P
103.3
126
Max. 10
Approx. 300
(Lead wire length)
151.6
(Indicator light)
160.2 [150.2]
170.2 [160.2]
Applicable cable O.D.
ø4.5 to ø7
[ ]: Without indicator light
Unless otherwise indicated, dimensions are the same as Grommet (G).
1856
Series VP300/500/700
Made to Order
Please contact SMC for detailed dimensions, specifications, and lead times.
1 Pilot Exhaust Port with Piping Thread (M3) Specification
In this specification, piping to the pilot exhaust port (PE port) is available when the valve is used in an environment where the
exhaust from the pilot valve is not allowable, or intrusion of ambient dust should be prevented.
How to Order Valve
3
VP 5 4 24
1
7
Pilot exhaust port (PE port)
M3 x 0.5
X500
Entry is the same as standard products.
The specifications, performance and external
dimensions are the same as those of standard models.
2 Body Ported Interchangeable Specification with the Previous Valve Mounting Hole Pitch Type
The mounting hole has been changed to the long type in order to provide interchangeability with the previous VP300/500 series.
How to Order Valve
VP 35 42
1
X505
Entry is the same as standard products.
The specifications, performance and external dimensions are the same as those of standard models.
Note) VP742 is not available because the mounting
hole pitch is the same as the previous type.
VP542
28
21.5
VP342
SYJ
15
VQZ
22
VP
3 TRIAC Output Specification
VG
For AC type valve, use this specification when the pilot valve is not recovered even though valve power supply is turned OFF at
the equipment using output unit with large leakage voltage over 8 % of the rated voltage (TRIAC output such as PLC or SSR, etc.)
How to Order Valve
3
VP 5 4
X600
7
Entry is the same as standard products.
Note) Rated voltage: AC type only
1857
VP3
Series VP
Specific Product Precautions 1
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions, pages 3 to 8 for 3/4/5 Port Solenoid
Valves Precautions.
Manual Override
Warning
How to Use L/M-Type Plug Connector
Caution
Without an electric signal for the solenoid valve the
manual override is used for switching the main valve.
Connected actuator is started by manual operation.
Use the manual override after confirming that there is
no danger.
 Non-locking push type
1. Attaching and detaching connectors
• To attach a connector, hold the lever and connector unit
between your fingers and insert straight onto the pins of the
solenoid valve so that the lever’s pawl is pushed into the
groove and locks.
• To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
connector straight out.
Push down on the manual
override button with a small
screwdriver until it stops.
Release the screwdriver
and the manual override
will return.
Cover
Groove
Pin
Cover
Pin
Lever
DC polarity indication
Connector
 Push-turn locking slotted type
Socket
Groove
Locked condition
Lead wire
Lever
2. Crimping lead wires and sockets
Not necessary if ordering the lead wire pre-connected model.
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
ends of the core wires evenly into the sockets, and then crimp
with a crimping tool. When this is done, take care that the
coverings of the lead wires do not enter the core wire crimping
area. (Please contact SMC for details on the crimping tool.)
Push the manual override button with a small flat head
screwdriver until it stops. Turn it in the clockwise direction at 90°
to lock the manual. Turn it counterclockwise to release it.
Core wire
Crimping area
crimping area
Socket
Core wire
(Part no.: DXT170-71-1)
Lead wire
Insulation
Hook
 Push-turn locking lever type
Locked condition
After pushing down, turn in the direction of the arrow. If it is not
turned, it can be operated the same way as the non-locking type.
Caution
When locking the manual override with the push-turn locking type
(D or E type), be sure to push it down before turning.
Turning without first pushing it down can cause damage to the
manual override and other trouble such as air leakage, etc.
Do not apply excessive torque when turning the locking type
manual override. (0.1 N·m)
1858
0.2 to 0.33 mm2
Max. cover diameter: ø1.9 mm
3. Attaching and detaching sockets with lead wire
• Attaching
Insert the sockets into the square holes of the connector ( ,
indication), and continue to push the sockets all the way in
until they lock by hooking into the seats in the connector.
(When they are pushed in, their hooks open and they are
locked automatically.) Then, confirm that they are locked by
pulling lightly on the lead wires.
• Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket’s hook with a stick having a thin tip
(approx. 1 mm). If the socket will be used again, first spread
the hook outward.
Socket
Hook
Connector
Lead wire
Insert a socket into square hole
Not in use
Series VP
Specific Product Precautions 2
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions, pages 3 to 8 for 3/4/5 Port Solenoid
Valves Precautions.
Plug Connector Lead Wire Length
How to Use DIN Terminal
The DIN terminal type with an IP65 enclosure is protected
against dust and water, however, it must not be used in water.
Caution
Plug connector lead wires have a standard length of
300 mm, however, the following lengths are also
available.
How to Order Connector Assembly
DC
: V200-30-4A-
100 VAC
: V200-30-1A-
200 VAC
: V200-30-2A-
AC other voltages : V200-30-3AWithout lead wire : V200-30-A
(With connector and 2 pcs. of socket)
Lead wire length
Nil
6
10
15
20
25
30
50
300 mm
600 mm
1000 mm
Caution
Connection
1) Loosen the set screw and pull the connector out of the
solenoid valve terminal block.
2) After removing the set screw, insert a flat head screwdriver,
etc. into the notch on the bottom of the terminal block and pry
it open, separating the terminal block and the housing.
3) Loosen the terminal screws on the terminal block, insert the
core of the lead wire into the terminal, and attach securely with
the terminal screws.
In addition, when using the DC mode type with a surge
voltage suppressor (polar: S and Z types), connect wires
corresponding to the polarity (+ or –) that is printed on the
terminal block.
4) Tighten the ground nut to secure the wire.
In the case of connecting wires, select cabtire cords carefully
because if those out of the specified range (ø4.5 to ø7) are
used, it will not be able to satisfy IP65 (enclosure).
Tighten the ground nut and set screw within the specified
range of torque.
Changing the entry direction
3000 mm
After separating terminal block and housing, the cord entry
direction can be changed by attaching the housing in the
opposite direction.
∗ Make sure not to damage elements, etc., with the lead wires of
the cord.
5000 mm
Precautions
1500 mm
2000 mm
2500 mm
How to Order
Include the connector assembly part number together with the
part number for the plug connector’s solenoid valve without
connector.
(Example) 2000 mm lead wire length
DC
AC
VP342-5LO1-01A
VP342-1LO1-01A
V200-30-4A-20
V200-30-1A-20
Plug in and pull out the connector vertically without tilting to one
side.
Applicable cable
Cable O.D.: ø4.5 to ø7
(Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
JIS C 3306
Applicable crimped terminal
O terminal: R1.25-4M that is specified in JIS C 2805
Y terminal: 1.25-3L, which is released by JST Mfg. Co., Ltd.
Stick terminal: Size 1.5 or shorter
SYJ
VQZ
Ground nut
Tightening torque
2.5 to 3.75 N·m
VP
Set screw
Tightening torque
0.5 to 0.6 N·m
Washer
VG
Housing
VP3
Grommet
(Rubber)
Terminal block
(Location for
light mounting)
(Voltage symbol)
–
+
Terminal screw
3 locations
Tightening torque
0.4 to 0.5 N·m
(Polarity indication)
1859
Series VP
Specific Product Precautions 3
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions, pages 3 to 8 for 3/4/5 Port Solenoid
Valves Precautions.
DIN (EN175301-803) Terminal
How to Use Conduit Terminal
Y type DIN terminal corresponds to the DIN connector with
terminal pitch 10 mm, which complies with EN175301-803B.
Since the terminal pitch is different from the D type DIN
connector, these two types are not interchangeable.
10
11
8.5
D type
5.5
Y type
Caution
-1
 With indicator light
DC
Polar type (Z)
: V200-
-3-
Non-polar type (U) : V200-
-5-
1) Loosen the set screw and remove the terminal block cover
from the terminal block.
2) Loosen the terminal screws on the terminal block, insert the
core of the lead wire or crimped terminal
into the terminal, and attach securely with
the terminal screws.
In addition, when using the DC mode type
with a surge voltage suppressor (polar: S
(+)
(–)
and Z types), connect wires to terminal 1
and 2 corresponding to the polarity (+ or –)
as shown on the right figure.
3) Secure the cord by fastening the ground nut.
In the case of connecting wires, select cabtire cords carefully
because if those out of the specified range (ø4.5 to ø7) are used,
it will not be able to satisfy IP65 (enclosure).
Tighten the ground nut and set screw within the specified range
of torque.
-2A
-66
Set screw
200
V
Tightening torque
bly
m
e
0.5 to 0.6 N·m
ass
er
cov
Terminal block
ck
o
l
cover
Grommet
al b
n
i
(Rubber)
rm
Te
How to Order DIN Connector
 Without indicator light
DC, AC, Other voltages: V200-
Caution
Connection
Rated voltage
Ground nut
Tightening torque
2.5 to 3.75 N·m
Washer
05 24 VDC
06 12 VDC
: V200-
AC (Z)
61
63
Y type
01 100/110 VAC [115 VAC]
02 200/220 VAC [230 VAC]
07 240 VAC
Note) For 24 VAC specifications, the order
number is V200-61/63-5-B.
Circuit with indicator light (Built-in connector)
AC (Z) circuit
NL
R
NL: Neon bulb R: Resistor
R
LED
LED: Light emitting diode, R: Resistor
DC (Z) circuit
+
1860
LED
Note) The 24 VAC
specifications are the
same as those in the DC
(U) circuit diagram.
−
R
D
(2 locations)
Tightening torque
0.5 to 0.6 N·m
Rated voltage
D type
DC (U) circuit
Terminal screw
-7-
Connector specification
Ground terminal
screw
Tightening torque
0.5 to 0.6 N·m
LED: Light emitting diode
D: Protective diode
R: Resistor
Applicable cable
Cable O.D.: ø4.5 to ø7
(Reference) 0.5 mm2 to 1.5 mm2, 2-core or 3-core, equivalent to
JIS C 3306
Applicable crimped terminal
O terminal: Equivalent to R1.25-3 that is specified in JIS C 2805
Y terminal: Equivalent to 1.25-3, which is released by JST Mfg.
Co., Ltd.
∗ Use O terminal when a ground terminal is used.
Series VP
Specific Product Precautions 4
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions, pages 3 to 8 for 3/4/5 Port Solenoid
Valves Precautions.
Light/Surge Voltage Suppressor
Caution
<DC>
 Polar type
With surge voltage suppressor (S)
Polarity protection diode
 With power saving circuit
Power consumption is decreased by approx. 1/3 by reducing
the wattage required to hold the valve in an energized state.
(Effective energizing time is over 40 ms at 24 VDC.)
Refer to the electrical power waveform as shown below.
Red(+)
Coil
<Electrical power waveform of energy saving type>
Black(−)
Applied voltage
24 V
 Grommet or L/M-type plug connector
With light/surge voltage suppressor (Z) Polarity protection diode
0V
Red(+)
LED
Coil
Black(−)
Standard
1.55 W
 DIN or Conduit terminal
With light/surge voltage suppressor (Z)
Polarity protection diode
Diode
LED
(−)
 Non-polar type
With surge voltage suppressor (R)
0W
40 ms
Coil
For DIN type, installed
in the connector
• Since the voltage will drop by approx. 0.5 V due to the transistor, pay attention to the allowable voltage fluctuation. (For
details, refer to the solenoid specifications of each type of
valve.)
Polarity protection diode
(+, −)
(+)
Varistor
Coil
Coil
(−, +)
Diode
LED
(−)
 Grommet or L/M-type plug connector
With light/surge voltage suppressor (U)
<AC>
(+, −)
Varistor
(−, +)
Coil
There is no S option, since a rectifier prevents surge voltage
generation.
 Grommet or L/M-type plug connector
With light/surge voltage suppressor (Z)
Varistor
LED
VP
(∼)
(+, −)
Varistor
Coil
LED
VG
Coil
VP3
(∼)
For DIN type, installed
in the connector
• Please connect correctly the lead wires to + (positive) and –
(negative) indications on the connector. (For non-polar type, the
lead wires can be connected to either one.)
• When the valve with mis-wiring protection diode is used, the
voltage will drop by approx. 1 V. Therefore, pay attention to the
allowable voltage fluctuation (For details, refer to the solenoid
specification of each type of valve).
• Solenoids, whose lead wires have been pre-wired: + (positive)
side red and – (negative) side black.
SYJ
VQZ
LED
 DIN or Conduit terminal
With light/surge voltage suppressor (U)
(−, +)
PWM circuit
(+)
With power saving circuit
0.55 W
 DIN or Conduit terminal
With light/surge voltage suppressor (Z)
(∼)
NLNote)
(∼)
Varistor
Coil
NL: Neon bulb
For DIN type, installed in the connector
Note) LED for 24 VAC.
1861
Series VP
Specific Product Precautions 5
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions, pages 3 to 8 for 3/4/5 Port Solenoid
Valves Precautions.
Light/Surge Voltage Suppressor
Cautions for Replacing the Old VP Series with the New VP Series
Caution
Caution
Residual voltage of the surge voltage suppressor
Note) if a varistor or diode surge voltage suppressor is used,
there is some residual voltage to the protection element
and rated voltage. Therefore, refer to the table below and
pay attention to the surge voltage protection on the controller side. Also, since the response time does change, refer
to the specifications on page 1835 and 1842.
Mounted valve
New VP
Old VP
Manifold type
VV3P
-
41
42 -
(Internal pilot type)
Residual Voltage
VV3P 41
42 R--
DC
Surge voltage suppressor
S, Z
R, U
Selection method is different when the external pilot
manifold of the old VP series is used and the mounted
valves are replaced with the new VP series valve.
24
AC
12
Approx. 1 V
—
Approx. 1 V
Approx. 47 V
Approx. 32 V
Type of Actuation Changing
(External pilot type)
Internal pilot
Internal pilot
External pilot
Internal pilot
(How to identify the external pilot manifold)
If the external pilot port is connected, it is the external pilot
manifold.
External pilot port
Warning
When changing the actuation or restarting the valve
after the change, make sure that safety is fully
assured and pay great attention.
Example: Changing from N.C. to N.O.
1) Base mounted
<N.C.>
<N.O.>
One-touch Fittings
N.C.
Caution
N.O.
1. Remove the body from the sub-plate and reset the “ ” mark
on the body corresponding to the “N.O.” mark on the sub-plate
as shown in the figure above.
2. Remove the end plate from the body and rotate the end plate
by 180° so that the “N.O.” mark on the end plate is at the top
of the valve.
∗ It is not necessary to change the piping when this is done.
2) Body ported
When fittings are used, they may interfere with one another
depending on their types and sizes. Therefore, the dimensions of
the fittings to be used should first be confirmed in their respective
catalogs.
Fittings whose compliance with the VP series is already
confirmed are stated below. If the fitting within the applicable
range is selected, there will not be any interference.
Applicable Fittings: Series KQ2H, KQ2S
Series
VP(A)300
<N.C.>
<N.O.>
N.C.
N.O.
VP(A)500
VP(A)700
 Remove the end plate from the body and rotate the end plate
by 180° to correspond the “N.O.” mark on the end plate to the
top of the valve.
∗ Piping should be arranged as follows.
Type
of actuation
N.C.
N.O.
1862
Port
1P
2A
3R
Inlet side Outlet side Exhaust side
Exhaust side Outlet side
Inlet side
Piping
port
Port
size
1P, 2A, 3R 1/8, 1/4
X
M5
1P, 2A, 3R 1/4, 3/8
X
1/8
1P, 2A, 3R 3/8, 1/2
X
1/8
VV3P(A)3 1P, 2A, 3R
Manifold base
X
1/4
VV3P(A)5 1P, 2A, 3R
Manifold base
X
3/8
VV3P(A)7 1P, 2A, 3R
Manifold base
X
1/2
M5
M5
1/8
Applicable tubing O.D.
ø3.2
ø4
ø6
ø8
ø10
ø12
ø16
Large Size 3 Port Solenoid Valve
Series VP3145/3165/3185
Rubber Seal
[Option]
Large flow capacity, small
exhaust resistance
(Refer to “Flow Characteristic” table.)
Easy conversion to N.C. or
N.O.
How to Order
VP3 1 4 5
Note) CE-compliant: D/DL/DS/DZ
only (Electrical entry)
04 1 G A
Series VP 3 port
Function plate makes it possible to use solenoid valve
as a N.C. or N.O. valve with the port
Number of
unchanged.
solenoids
Possible to use in vacuum
or under low pressures
1
CE-compliant
CE-compliant Note)
Note) Electrical entry:
D/DL/DS/DZ only
Single
Body size
Vacuum: Up to 101.2 kPa
Low pressure: 0 to 0.2 MPa
4
6
8
Free mounting orientation
Thread type
12
Nil
F
N
T
1
112
Body type
5
Body ported
Nil
1
For general
For vacuum/low pressure
A N.C. (Normally closed)
B N.O. (Normally open)
Port size
Symbol Rc (Nominal size) VP3145 VP3165 VP3185
Symbol
Internal pilot
<Standard>
3 8 (10A)
1 2 (15A)
Electrical entry
3 4 (20A)
1 (25A)
1 1 4 (32A)
1 1 2 (40A)
2 (50A)
Coil rated voltage
1
2
3∗
4∗
(OUT)
2
(OUT)
2
1 3
(IN) (EXH)
5
6∗
7∗
1 3
(IN) (EXH)
N.C.
9∗
N.O.
VT3113
X
(PA)
N.C.
∗ Semi-standard
SYJ
VQZ
How to Order Pilot Valve Assembly
(OUT)
2
1 3
(IN) (EXH)
100 VAC, 50/60 Hz
200 VAC, 50/60 Hz
110 VAC, 50/60 Hz
220 VAC, 50/60 Hz
24 VDC
12 VDC
240 VAC, 50/60 Hz
Other
CE-compliant
G
Grommet
Conduit terminal
T
D
DIN terminal
TL∗ Conduit terminal with indicator light
TS∗ Conduit terminal with surge voltage suppressor
TZ∗ Conduit terminal with light/surge voltage suppressor
DL∗
DIN terminal with indicator light
DS∗ DIN terminal with surge voltage suppressor
DZ∗ DIN terminal with light/surge voltage suppressor
∗ Semi-standard
External pilot
(OUT)
2
Standard (Internal pilot)
External pilot
Type of actuation
Port size (IN, OUT port)
03
04
06
10
12
14
20
Rc
G
NPT
NPTF
Pilot option
Valve option
Nil
V
—
Nil
Q
1 3
(IN) (EXH)
X
(PA)
N.O.
Note) N.O. valve operates properly only when
appropriate pressure is applied to the
pilot.
Made to Order
(Refer to pages 1875 to 1877 for details.)
Coil rated voltage
VP
VG
00 1 G
Electrical entry
VP3
CE-compliant
G
Grommet
1
100 VAC, 50/60 Hz
Conduit terminal
T
2
200 VAC, 50/60 Hz
D
DIN terminal
CE-compliant
3∗ 110 VAC, 50/60 Hz
TL∗ Conduit terminal with indicator light
—
Nil
4∗ 220 VAC, 50/60 Hz
TS∗ Conduit terminal with surge voltage suppressor
Q CE-compliant Note)
5
24 VDC
TZ∗ Conduit terminal with light/surge voltage suppressor
Note) Electrical entry:
6∗
12 VDC
DL∗
DIN terminal with indicator light
D/DL/DS/DZ only
7∗ 240 VAC, 50/60 Hz
DS∗ DIN terminal with surge voltage suppressor
9∗
Other
DZ∗ DIN terminal with light/surge voltage suppressor
∗ Semi-standard
∗ Semi-standard
Note) The pilot valve assembly shown above includes the function plate and gasket.
1869
Series
VP3145/3165/3185
Specifications
External Pilot
Use external pilot model in the following
cases.
• Vacuum or low pressure (0.2 MPa or less):
Vacuum/Low pressure type
• Using the valve with supply port external throttle:
General type
• Air pressure of supply port is slow:
General type
• Resistance in outlet side is small in case of
air blowing or filling an air tank:
General type
Note 1) Keep external pilot pressure within
the pressure range below.
Note 2) Conversion of internal pilot and
external pilot can not be done.
For vacuum/
low pressure
Fluid
Type of actuation
Air
N.C. or N.O. (Convertible)
External pilot
Internal pilot
For general For vacuum/low pressure For general
Pilot type
Main pressure
Operating pressure range (MPa)
–101.2 kPa to 0.2
0.2 to 0.8
0.2 to 0.3
Refer to
the graph left.
0.2 to 0.8
Pilot pressure
Ambient and fluid temperature (°C)
Response time (ms) (1)
(at the pressure of 0.5 MPa)
Max. operating frequency (Hz)
Lubrication (2)
Manual override
Mounting orientation
Impact/Vibration resistance (m/s2) (3)
0 (No freezing) to 60
30 or less
AC 30 or less
OFF
40 or less
DC 30 or less
3
Required (Equivalent to turbine oil Class1 ISO VG32)
Yes (Non-locking)
Unrestricted
150/50
ON
AC
DC
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated
voltage, without surge voltage suppressor)
Note 2) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition.
(Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000 Hz.
Test was performed at both energized and de-energized states in the
axial direction and at the right angles to the main valve and armature.
(Values at the initial period)
Pilot pressure (MPa)
For general
Solenoid Specifications
Grommet (G), Conduit terminal (T)
DIN terminal (D)
Conduit terminal with indicator light (TL),
Conduit terminal with surge voltage suppressor (TS),
Electrical entry
Conduit terminal with light/surge voltage suppressor (TZ),
Option
DIN terminal with indicator light (DL),
DIN terminal with surge voltage suppressor (DS),
DIN terminal with light/surge voltage suppressor (DZ)
AC ( 50 60 Hz)
100, 200, 110 ∗, 220 ∗, 240 ∗
Coil rated voltage (V)
DC
12 ∗, 24
Allowable voltage fluctuation
–15 to +10% of rated voltage
Inrush
73 VA (50 Hz), 58 VA (60 Hz)
Apparent power Note)
AC
Holding
28 VA (50 Hz), 17 VA (60 Hz)
Note)
Power consumption
DC
12 W
∗ Semi-standard
Note) At rated voltage
Standard
Main pressure (MPa)
Flow Characteristics/Weight
1(IN), 2(OUT)
1  2 (IN  OUT)
VP3145
3(EXH)
38
12
34
34
Port size
Valve model
1 (IN), 2 (OUT)
VP3185
1
11 4
11 4
11 2
2
∗ For grommet
Conduit terminal··· +0.2 kg
1870
C
[dm3/(s·bar)]
19
23
28
3(EXH)
11 4
2
2  3 (OUT  EXH)
b
Cv
0.43
0.32
0.36
5.5
6.2
7.6
Effective area (mm2)
34
VP3165
Weight ∗
(kg)
Flow characteristics
Port size
Valve model
C
[dm3/(s·bar)]
18
21
26
Weight ∗
(kg)
1  2 (IN  OUT) 2  3 (OUT  EXH) Grommet
230
280
2.0
280
310
310
330
570
650
2.8
650
670
650
670
b
Cv
Grommet
0.47
0.39
0.35
5.4
5.8
7.0
1.5
Large Size 3 Port Solenoid Valve
Series
VP3145/3165/3185
Construction/Internal Pilot
As in the figure below, this pilot-operated solenoid valve consists of a
compact 3 port solenoid valve as the pilot valve and a large 3 port valve
as the main valve.
The pilot valve controls opening and closing the main valve. N.C. or N.O.
function conversion can be done by switching the pilot passage.
Overtravel spring
Keeps surface pressure against the valve
constant and compensates for stroke.
Pilot valve
Solenoid
Manual
override
Return spring
Pilot air supply port
Internal pilot
Function plate
N.C. or N.O.
conversion possible
Housing
Has pilot exhaust port and
external pilot supply port.
Pilot pressure
receiving chamber
External pilot type
Main valve
Pressure-return style poppet
valve with special mechanism.
Body
Wear-resistant aluminum alloy
Sintered bronze
Element
Return spring
Assures returning
in case of drop-out.
Note) Pilot valve and body are shown in a different direction from
the actual product in order to show the construction and air
passage.
Piping (Vacuum Use)
1. Piping in general:
Vacuum pump/ (Suction side)
Blower
(Load side)
OUT port = Tank/
Vacuum pad
Plug (2 port valve)
IN port = Air releasing
Air pressure-in
EXH port =
2. Following the above piping, vacuum
passage is switched between OUT and
EXH, therefore, N.C./N.O. indication on
the function plate and switching of the
vacuum passage are reversed; N.C.
(Normally closed) in vacuum passage are
reversed:
N.C./N.O. Conversion
To convert valve operation from N.C. to N.O.
or N.O. to N.C., remove the pilot valve, move
the function plate along the gasket, both top
and bottom until the mark  meets N.C.
(N.O.)
Please note however, that the N.O. valve
functions properly only when the appropriate
pressure is applied to the valve.
SYJ
VQZ
Pilot valve
VP
Function
plate
VG
VP3
“N.C.” indicated on the plate
 N.O. in vacuum passage
(Normally open)
“N.O.” indicated on the plate
 N.C. in vacuum passage
(Normally closed)
1871
Series
VP3145
Dimensions: VP3145
Grommet: VP3145-G AB 
Manual
override
External pilot port
Lead wire length 200 mm
(EXH port)
(PE port)
Mounting
hole
(IN, OUT port)
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
A
B
Conduit terminal: VP3145-T 
DIN terminal: VP3145-DAB 
Conduit terminal with indicator light (TL)
Light
[ ]: With indicator light (TL)
1872
Light
position
Max. 11
Applicable cable ø6 to ø12
Large Size 3 Port Solenoid Valve
Series
VP3165
Dimensions: VP3165
Grommet: VP3165-G AB 
Manual
override
External pilot port
Lead wire length 200 mm
(PE port)
(EXH port)
Mounting
hole
(IN, OUT port)
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
Conduit terminal: VP3165-T AB 
Conduit terminal with indicator light (TL)
Light
DIN terminal: VP3165-DAB 
Light
position
Max. 11
Applicable cable ø6 to ø12
SYJ
VQZ
VP
VG
VP3
[ ]: With indicator light (TL)
1873
Series
VP3185
Dimensions: VP3185
Grommet: VP3185-G AB 
Manual
override
External pilot port
Lead wire length 200 mm
(PE port)
(EXH port)
Mounting
hole
(IN, OUT port)
Note) External pilot port Rc 1/4 is processed for threads in external pilot model only.
A
B
Conduit terminal: VP3185-T 
DIN terminal: VP3185-DAB 
Conduit terminal with indicator light (TL)
Light
Light
position
[ ]: With indicator light (TL)
1874
Max. 11
Applicable cable ø6 to ø12
Note) CE-compliant: D/DO only
(Electrical entry)
VP3145/3165/3185
Made to Order
Series
[Option]
Please contact SMC for detailed dimensions, specifications and lead times.
Symbol
1 Main Value Double Acting Type
-X80, -X81
VP31 4 5 06 1 D Z A 1 N X 81
CE-compliant
Body size
4
6
8
Nil
1 2
11 2
Thread type
Port size (IN, OUT port)
Symbol Port size
38
03
12
04
34
06
10
1
12
114
14
112
20
2
Nil
F
N
T
VP3145 VP3165 VP3185
A
B
80
81
Double solenoid
Single solenoid
N.C.
N.O.
In the case of -X80, only
N.C. is available.
100 VAC, 50/60 Hz
200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz
220 VAC, 50/60 Hz
24 VDC
12 VDC
240 VAC, 50/60 Hz
Other
5
6∗
7∗
9∗
Type of actuation
Rc
G
NPT
NPTF
Passage,
Type of actuation
Coil rated voltage
1
2
3∗
4∗
—
CE-compliant Note)
Q
Note) Electrical entry: D/DO
only
1
Light/Surge voltage suppressor
Electrical entry
∗ Semi-standard
L, M plug connector is 220 VAC at the
maximum.
G
H
E
T
D
DO
L
LN
LO
M
MN
MO
CE-compliant
Grommet (Lead wire: 300 mm)
Grommet (Lead wire: 600 mm)
Grommet terminal
Conduit terminal
With connector
DIN terminal
Without connector
With lead wire
L plug connector
Without lead wire
Without connector
With lead wire
M plug connector Without lead wire
Without connector
Nil
None
Z
With light/surge voltage suppressor
S
With surge voltage suppressor
∗ Indicator light is not available for grommet
type. With surge voltage suppressor is
available for grommet type only.
How to Order Pilot Valve Assembly
VF3
40
CE-compliant
Type of actuation
1
2
Single solenoid
Double solenoid
Light/Surge voltage suppressor
5
6∗
7∗
9∗
100 VAC, 50/60 Hz
200 VAC, 50/60 Hz
110 to 120 VAC, 50/60 Hz
220 VAC, 50/60 Hz
24 VDC
12 VDC
240 VAC, 50/60 Hz
Other
∗ Semi-standard
L, M plug connector is 220 VAC at the
maximum.
—
Q
CE-compliant Note)
Note) Electrical entry: D/DO
Nil
None
only
Z
With light/surge voltage suppressor
S
With surge voltage suppressor
∗ Indicator light is not available for grommet
type. With surge voltage suppressor is
available for grommet type only.
Coil rated voltage
1
2
3∗
4∗
Nil
Electrical entry
G
H
E
T
D
DO
L
LN
LO
M
MN
MO
SYJ
VQZ
VP
VG
VP3
CE-compliant
Grommet (Lead wire: 300 mm)
Grommet (Lead wire: 600 mm)
Grommet terminal
Conduit terminal
With connector
DIN terminal
Without connector
With lead wire
L plug connector
Without lead wire
Without connector
With lead wire
M plug connector Without lead wire
Without connector
1875
Series
VP3145/3165/3185
Specifications
Symbol
-X80
Valve configuration
Type of actuation
Fluid
Operating pressure range
Pilot pressure
Ambient and fluid temperature
Lubrication (1)
Mounting orientation
Impact/Vibration resistance (2)
(OUT)
2
1 3
(IN) (EXH)
X
(PA)
N.C.
Note 1) This solenoid valve requires lubrication. Use turbine oil Class 1 (ISO VG32).
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition.
(Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 1000
Hz. Test was performed at both energized and de-energized states
in the axial direction and at the right angles to the main valve and
armature. (Values at the initial period)
-X81
(OUT)
2
(OUT)
2
1 3
(IN) (EXH)
1 3
(IN) (EXH)
X
(PA)
N.C.
External pilot 3 port solenoid valve
Double solenoid (-X80), Single solenoid (-X81)
Air
–101.2 kPa to 0.8 MPa
85 to 115% of main pressure, Min. 0.2 MPa
0 to 50°C (No freezing)
Required (Equivalent to turbine oil Class 1 ISO VG32)
Unrestricted
150/50 m/s2
Solenoid Specifications
X
(PA)
N.O.
Electrical entry
Grommet, Grommet terminal, Conduit terminal
DIN terminal, L plug connector, M plug connector
Coil rated voltage (V)
AC (50/60 Hz)
DC
100, 200, 110∗, 220∗, 240∗
24, 12∗
Allowable voltage fluctuation
Apparent power (AC)
Note)
Power consumption (DC)
Note)
–15 to 10%
5.6 VA/50 Hz, 5.0 VA/60 Hz
3.4 VA/50 Hz, 2.3 VA/60 Hz
1.8W
2W
Inrush
Holding
W/o indicator light
W/ indicator light
∗ Semi-standard
Note) At rated voltage
Caution
Piping and other usage are the same as standard products.
Dimensions
VP3145-DZA1-X81
35
134
Max.10
21
87.4
80
71
51
EXH.1
EXH.2
Manual override
(Non-locking)
Applicable cable O.D.
ø6 to ø8
Pg9
2 x 1/8
(Pilot EXH)
1/4
(External pilot
port)
71
93
112
25
3/4
(EXH port)
42
IN
62
65
EXH
42
OUT
36
196.1
PA
156
119
103
PE
205.1
2 x ø8.5
(Mounting hole)
EXH
2 x 3/8, 1/2, 3/4
(IN, OUT port)
36
• When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be
positioned at left, when looking at the EXH port in the front face.
• In the case of -X80, VF3240- (Pilot valve) will be mounted.
1876
VP3145/3165/3185
Series
Large Size 3 Port Solenoid Valve
Dimensions
VP3165-DZA1-X81
21
21
146.5
113
87.4
Max.10
95
71
51
EXH.1
EXH.2
Manual override
(Non-locking)
Applicable cable O.D.
Pg9
ø6 to ø8
1/4
2 x 1/8
(External pilot
port)
Pilot EXH
2 x ø8.5
PA
IN
118
55
EXH
25
55
OUT
78
85
144
128
137
PE
221
230
(Mounting hole)
EXH
1 1/4
36
(EXH port)
82.6
36
2 x 3/4 , 1, 1 1 /4
(IN, OUT port)
• When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.
• In the case of -X80, VF3240- (Pilot valve) will be mounted.
VP3185-DZA1-X81
Max.10
160.3
140
87.4
105
81
76
56
26.5
6
EXH.1
EXH.2
Manual override
(Non-locking)
Applicable cable O.D.
Pg9
ø6 to ø8
1/4
2 x 1/8
SYJ
(External pilot
port)
Pilot EXH
VQZ
2 x ø13
(Mounting hole)
VP
PA
41
118
IN
140
VG
VP3
62
EXH
25
62
OUT
90
105
166
150
159
PE
243.1
250.7
EXH
2
(EXH port)
41
2 x 1 1/4, 1 1 /2, 2
(IN, OUT port)
• When B spec. of -X81 (N.O. spec.), VF3140 solenoid has to be positioned at left, when looking at the EXH port in the front face.
• In the case of -X80, VF3240- (Pilot valve) will be mounted.
1877
Series VP3145/3165/3185
Specific Product Precautions
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions and pages 3 to 8 for 3/4/5 Port
Solenoid Valve Precautions.
Caution
Light/Surge Voltage Suppressor
Piping
Use as 2 port valve
1. Plug EXH port in case of pressure-in
and plug IN port in case of vacuum
use.
2. This valve has slight air leakage and
can not be used for such purposes as
holding air pressure (including
vacuum) in the pressure container.
Supply air
Install an air filter and a lubricator on the
upstream side.
Lubrication
This solenoid valve requires lubrication.
Use turbine oil Class 1 (ISO VG32).
As for details, refer to page 6.
Environment
If using the valve in a dusty environment,
install a silencer at EXH port and PE port
to prevent dust from entering.
N.C./N.O. conversion
When changing the direction of a function
plate to convert from N.C. to N.O. and vice
versa, note that the equipment to be
connected will act reversely.
How to Calculate the Flow Rate
For obtaining the flow rate, refer to front
matters 42 to 45.
With light/surge
voltage
suppressor (Z)
Varistor
48 VDC or less
Neon bulb
None
Varistor
Coil
100 VAC or more
Neon bulb
LED
Varistor
Varistor
“Items that are marked “With indicator light,” “With surge voltage suppressors,” and “With light/surge
voltage suppressor” are all non-polar types.
How to Use DIN Terminal
1. Disassembly
1) After loosening the screw q, then if the
housing r is pulled in the direction of the
screw, the connector will be removed from
the body of equipment (solenoid, etc.).
2) Pull out the screw q, then remove the
gasket or .
3) On the bottom part of the terminal block
e, there’s a cut-off part (indication of an
arrow) . If a small flat head screwdriver
is inserted between the opening in the
bottom, terminal block e will be
removed from the cover r.
(Refer to the figure below.)
4) Remove the cable gland t and plain
washer y and rubber seal u .
2. Wiring
1) Pass them through the cable i in the
order of cable ground t, washer y,
rubber seal u, and then insert into the
housing r.
2) Dimensions of the cable i are the figure
as below. Skin the cable and crimp the
crimped terminal o to the edges.
3) Remove the screw with washer from the
bracket . (Loosen in the case of Y-shape
type terminal.) As shown in the below
figure, mount a crimped terminal o, and
then again tighten the screw .
3. Assembly
1) Terminal block e connected with
housing r should be reinstated.
(Push it down until you hear the click
sound.)
2) Putting rubber seal u, plain washer y,
in this order into the cable introducing slit
on the housing r, then further tighten
the cable gland t securely.
3) By inserting gasket
or
between the
bottom part of the terminal block e and
a plug on an equipment, screw in q on
top of the housing r and tighten it.
Note) Tighten within the tightening torque of
0.5 N·m ±20%.
Note: The orientation of a connector can be
changed arbitrarily, depending on the
combination of a housing r and a
terminal block e.
Exploded view
q
r
Note) Tighten within the tightening torque of
0.5 N·m ±15%.
Note: a It is possible to wire even in the state
of bare wire. In that case, loosen the
screw with washer and place a lead
wire
into the bracket, and then
tighten it once again.
b Maximum size of crimped terminal o
is up to 1.25 mm2 —3.5 when O
terminal. For Y terminal, it is up to
1.25 mm2 —4.
c Cable i outside diameter: ø6 to ø12 mm
Note) For the one with the outside diameter
ranged between ø9 to ø12 mm, remove
the inside parts of the rubber seal u
before using.
u
t
y
e
o
i
o
Magnifying
figure
2
1
3
1878
Neon bulb
Coil
Surge voltage
suppressor (S)
LED
Coil
Neon bulb
Coil
None
DIN terminal (D)
48 VDC or less
100 VAC or more
Coil
This solenoid valve is pressureunbalanced type. Operate it within this
pressure range: IN ≥ OUT ≥ EXH. If not
operated in the range, the valve will
malfunction.
With indicator
light (L)
Conduit terminal (T)
Coil
Pressure balance among each port
Grommet (G)
Coil
If supply port air pressure drops to less
than 0.2 MPa, the valve may malfunction.
In such a case, use external pilot type.
(When throttling IN port, or operating with
OUT port open to the atmosphere or in a
similar operation.)
Self-up screw