Steel Deck
Transcription
Steel Deck
IRD-150 ICD-150 ICD-300 Steel Deck Technical Catalog www.idealroofing.com IRD-300 Steel Deck ROOF DECK, FLOOR DECK AND ACOUSTIC DECK PANELS Ideal Roofing manufactures a complete range of coated steel roof, floor and acoustic deck panels using state-of-the-art roll-forming machinery. These panels are cut to length to your specifications and delivered to the job sites using Ideal’s own fleet of trucks. Check out Ideal Roofing’s wide range of roofing and siding panels on the last two pages of this catalog or visit www.idealroofing.com. To talk to a sales representative: 1 800 267-0860 Residential Commercial Industrial Table of Contents Page Deck Selection. 2 Roof Deck - IRD-150 / IRD-151 (Imperial) 3-4 - IRD-150 / IRD-151 (Metric)... 5-6 - IRD-300 / IRD-301 (Imperial) 7-8 - IRD-300 / IRD-301 (Metric)... 9-10 Composite Floor Deck - ICD-150 / ICD-151 (Imperial) 11-12 - ICD-150 / ICD-151 (Metric)... 13-14 - ICD-150 / ICD-151, INVERTED (Imperial).. 15-16 - ICD-150 / ICD-151, INVERTED (Metric). 17-18 - ICD-300 / ICD-301 (Imperial) 19-20 - ICD-300 / ICD-301 (Metric)... 21-22 - ICD-300 / ICD-301, INVERTED (Imperial).. 23-24 - ICD-300 / ICD-301, INVERTED (Metric). 25-26 Acoustic Deck & Metal Closures - IRD-150 / IRD-151.. 27 - IRD-300 / IRD-301.. 28 Profile Selection29-30 SECTION PROPERTIES (Per foot of width) IMPERIAL 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 Notes: Coated Steel Thickness (G90) (in.) Coated Weight (psf) 0.030 0.036 0.048 0.060 0.0315 0.0375 0.0495 0.0615 1.61 1.93 2.56 3.20 Sec. Modulus Midspan Support 3 3 (in. ) (in. ) 0.190 0.231 0.314 0.394 0.195 0.242 0.319 0.394 Deflection Moment of Inertia 4 BASE STEEL THICKNESS (inches) 0.030 0.036 0.048 0.060 278 339 460 578 421 529 705 877 204 249 338 425 265 333 444 552 157 191 259 325 178 223 297 370 124 151 204 257 125 157 209 260 100 122 166 208 91 114 152 189 83 101 137 172 68 86 114 142 70 85 115 144 53 66 88 110 59 72 98 123 41 52 69 86 51 62 84 106 33 42 55 69 45 54 74 92 27 34 45 56 39 48 65 81 22 28 37 46 35 42 57 72 19 23 31 39 31 38 51 64 16 20 26 32 28 34 46 58 13 17 22 28 25 30 41 52 11 14 19 24 23 28 38 47 10 12 16 20 21 25 34 43 9 11 14 18 1 2 3 4 Based on ASTM A 653 Grade 33 structural steel. Values in row "S" are based on strength. Values in row "D" are based on deflection of 1/240th span. Web crippling not included in strength calculations. See example. Pe2 End End Pi1 Pi2 Interior Interior (in. ) (lb) (lb) (lb) (lb) 174 258 477 765 43.5 64.5 119 191 305 456 853 1377 51.9 77.6 145 234 BASE STEEL THICKNESS (inches) S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D Specified Web Crippling Data Pe1 0.174 0.218 0.291 0.362 MAXIMUM UNIFORMLY DISTRIBUTED SPECIFIED LOADS (PSF) 1-SPAN 2-SPAN SPAN LENGTH (ft) 3.0 Base Steel Thickness (in.) 0.030 0.036 0.048 0.060 285 355 468 578 1010 1269 1691 2105 210 261 344 425 636 799 1065 1326 161 200 263 325 426 536 713 888 127 158 208 257 299 376 501 624 103 128 168 208 218 274 365 455 85 106 139 172 164 206 274 342 71 89 117 145 126 159 211 263 61 76 100 123 99 125 166 207 52 65 86 106 80 100 133 166 46 57 75 93 65 81 108 135 40 50 66 81 53 67 89 111 36 44 58 72 44 56 74 93 32 39 52 64 37 47 63 78 28 35 47 58 32 40 53 66 26 32 42 52 27 34 46 57 23 29 38 47 24 30 39 49 21 26 35 43 20 26 34 43 Limit States Design principles were used in accordance with CSA Standard S136-01 3-SPAN BASE STEEL THICKNESS (inches) 0.030 0.036 0.048 0.060 357 444 585 723 796 1000 1332 1658 262 326 430 531 501 630 839 1044 201 249 329 407 336 422 562 699 159 197 260 321 236 296 395 491 128 160 211 260 172 216 288 358 106 132 174 215 129 162 216 269 89 111 146 181 99 125 166 207 76 94 125 154 78 98 131 163 66 81 107 133 63 79 105 130 57 71 94 116 51 64 85 106 50 62 82 102 42 53 70 87 44 55 73 90 35 44 59 73 40 49 65 80 29 37 49 61 36 44 58 72 25 31 42 52 32 40 53 65 21 27 36 45 29 36 48 59 19 23 31 39 27 33 43 54 16 20 27 34 GENERAL INFORMATION General Presented in these load tables are maximum uniformly distributed specified loads. Limit States Design (LSD) Strength - Limit States Design principles were used in the development of the load tables in accordance with CSA-S136-01, North American Specification for the Design of Cold Formed Steel Structural Members and the National Building Code of Canada,. The factored resistance under consideration, φR, must be equal to or greater than the effect of the factored loads, i.e., φ R ≥ Effect of Factored Loads. Hence, a short calculation must be carried out to compute the specified live load. See example. Serviceability – Maximum specified deflection loads given in the tables must be compared with their respective specified live loads. Steel Specification - Conforms to ASTM A653M grade 230; Yield strength 230 MPa (33 ksi) and tensile strength of 310 MPa (45 ksi). Finishes – ZF 075 (A25) or Z275 (G90). For heavier galvanizing, refer to ASTM A653-A653M. Design Considerations Strength - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + 0.833 times the specified dead load). Where 0.833 = 1.25/1.5. Conservative Strength Approach - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + specified dead load). EXAMPLE 1 1/2” DECK (IMPERIAL) Given: Triple span continuous, L = 8 ft each span Deck thickness, t = 0.030 in L/180 deflection limit (data in tables are based on L/240) Bearing length, n = 2 in. Specified loads 1) Dead loads (DL) a) deck 1.6 psf b) superimposed 8.2 psf DL = 9.8 psf 2) Live load (LL) LL = 40 psf Solution: Strength 1) Specified loads [LL + 0.833 DL] [40 + 0.833 (9.8)] = 48.2 psf 2) Maximum specified load (from Table under “S”) is 50 psf Since 50 > 48.2 ∴ ΟΚ 3) Check end web crippling (n = 2 in.) a) Specified end reaction 0.400(48.2)8.0 = 154 lb/ft b) Maximum specified end reaction (from Section Property Table) Pe = Pe1 + Pe2 n / t Pe = 174 + 43.5 2 / 0.030 = 529 lb/ft Since 529 > 154 ∴ ΟΚ 4) Check interior web crippling (n = 2 in.) a) Specified interior reaction 1.10(48.2)8.0 = 424 lb/ft b) Maximum specified interior reaction (from Section Property Table) Pi = Pi1 + Pi2 n / t Pi = 305 + 51.9 2 / 0.030 = 729 lb/ft Since 729 > 424 ∴ ΟΚ Web Crippling Check – If n/t > 210, use n/t = 210. Serviceability (Deflection) – The effective moment of inertia for deflection determination has been calculated at an assumed specified live load stress of 0.6Fy. Deflection From Table under “D” (L/240) = 42 psf For L/180, multiply 42 by 240/180 = 56 psf. Since 56 is > 40 ∴ ΟΚ SECTION PROPERTIES (Per meter of width) METRIC 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 Notes: 0.762 0.914 1.219 1.524 0.802 0.954 1.259 1.564 Coated Mass 2 (kg/m ) 7.86 9.42 12.5 15.6 Sec. Modulus Midspan Support 3 3 3 3 (10 mm ) (10 mm ) 10.2 12.4 16.9 21.2 10.4 13.0 17.2 21.2 Specified Web Crippling Data Deflection Moment of Inertia 6 4 BASE STEEL THICKNESS (mm) 0.762 0.914 1.219 1.524 11.3 13.7 18.6 23.4 15.4 19.4 25.8 32.1 7.82 9.52 12.9 16.3 8.91 11.2 14.9 18.6 5.74 6.99 9.49 11.9 5.61 7.05 9.40 11.7 4.40 5.35 7.27 9.14 3.76 4.72 6.30 7.84 3.47 4.23 5.74 7.22 2.64 3.32 4.42 5.51 2.81 3.43 4.65 5.85 1.92 2.42 3.22 4.01 2.33 2.83 3.84 4.83 1.45 1.82 2.42 3.02 1.95 2.38 3.23 4.06 1.11 1.40 1.87 2.32 1.67 2.03 2.75 3.46 0.88 1.10 1.47 1.83 1.44 1.75 2.37 2.98 0.70 0.88 1.18 1.46 1.25 1.52 2.07 2.60 0.57 0.72 0.96 1.19 1.10 1.34 1.82 2.29 0.47 0.59 0.79 0.98 0.97 1.19 1.61 2.02 0.39 0.49 0.66 0.82 0.87 1.06 1.44 1.81 0.33 0.41 0.55 0.69 0.78 0.95 1.29 1.62 0.28 0.35 0.47 0.59 0.70 0.86 1.16 1.46 0.24 0.30 0.40 0.50 1 2 3 4 Based on ASTM A 653 Grade 230 structural steel. Values in row "S" are based on strength. Values in row "D" are based on deflection of 1/240th span. Web crippling not included in strength calculations. See example. Pe2 End Pi1 Pi2 Interior Interior (kN) (kN) (kN) (kN) 0.237 0.298 0.397 0.494 2.57 3.81 7.04 11.3 0.642 0.952 1.76 2.82 4.50 6.73 12.6 20.3 0.766 1.14 2.14 3.45 BASE STEEL THICKNESS (mm) S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D Pe1 End (10 mm ) MAXIMUM UNIFORMLY DISTRIBUTED SPECIFIED LOADS (kPa) 1-SPAN 2-SPAN SPAN LENGTH (m) 1.0 Base Steel Thickness (mm) Coated Steel Thickness (Z275) (mm) 0.762 0.914 1.219 1.524 11.5 14.4 18.9 23.4 36.9 46.4 61.9 77.1 8.01 9.97 13.2 16.3 21.4 26.9 35.8 44.6 5.88 7.33 9.66 11.9 13.5 16.9 22.6 28.1 4.50 5.61 7.40 9.14 9.02 11.3 15.1 18.8 3.56 4.43 5.84 7.22 6.33 7.96 10.62 13.2 2.88 3.59 4.73 5.85 4.62 5.80 7.74 9.63 2.38 2.97 3.91 4.83 3.47 4.36 5.81 7.24 2.00 2.49 3.29 4.06 2.67 3.36 4.48 5.57 1.71 2.12 2.80 3.46 2.10 2.64 3.52 4.38 1.47 1.83 2.41 2.98 1.68 2.12 2.82 3.51 1.28 1.60 2.10 2.60 1.37 1.72 2.29 2.85 1.13 1.40 1.85 2.29 1.13 1.42 1.89 2.35 1.00 1.24 1.64 2.02 0.94 1.18 1.58 1.96 0.89 1.11 1.46 1.81 0.79 1.00 1.33 1.65 0.80 0.99 1.31 1.62 0.67 0.85 1.13 1.40 0.72 0.90 1.18 1.46 0.58 0.73 0.97 1.20 Limit States Design principles were used in accordance with CSA Standard S136-01 3-SPAN BASE STEEL THICKNESS (mm) 0.762 0.914 1.219 1.524 14.4 18.0 23.7 29.3 29.1 36.6 48.8 60.7 10.0 12.5 16.4 20.3 16.8 21.2 28.2 35.1 7.35 9.16 12.1 14.9 10.6 13.3 17.8 22.1 5.63 7.01 9.24 11.4 7.10 8.93 11.9 14.8 4.45 5.54 7.30 9.03 4.99 6.27 8.36 10.4 3.60 4.49 5.92 7.31 3.64 4.57 6.09 7.59 2.98 3.71 4.89 6.04 2.73 3.43 4.58 5.70 2.50 3.12 4.11 5.08 2.10 2.64 3.53 4.39 2.13 2.66 3.50 4.33 1.66 2.08 2.77 3.45 1.84 2.29 3.02 3.73 1.33 1.67 2.22 2.76 1.60 1.99 2.63 3.25 1.08 1.35 1.81 2.25 1.41 1.75 2.31 2.86 0.89 1.12 1.49 1.85 1.25 1.55 2.05 2.53 0.74 0.93 1.24 1.54 1.11 1.38 1.83 2.26 0.62 0.78 1.04 1.30 1.00 1.24 1.64 2.03 0.53 0.67 0.89 1.11 0.90 1.12 1.48 1.83 0.45 0.57 0.76 0.95 GENERAL INFORMATION General Presented in these load tables are maximum uniformly distributed specified loads. Limit States Design (LSD) Strength - Limit States Design principles were used in the development of the load tables in accordance with CSA-S136-01, North American Specification for the Design of Cold Formed Steel Structural Members and the National Building Code of Canada,. The factored resistance under consideration, φR, must be equal to or greater than the effect of the factored loads, i.e., φ R ≥ Effect of Factored Loads. Hence, a short calculation must be carried out to compute the specified live load. See example. Serviceability – Maximum specified deflection loads given in the tables must be compared with their respective specified live loads. Steel Specification - Conforms to ASTM A653M grade 230; Yield strength 230 MPa (33 ksi) and tensile strength of 310 MPa (45 ksi). Finishes – ZF 075 (A25) or Z275 (G90). For heavier galvanizing, refer to ASTM A653-A653M. Design Considerations Strength - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + 0.833 times the specified dead load). Where 0.833 = 1.25/1.5. Conservative Strength Approach - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + specified dead load). EXAMPLE 38 mm (1 1/2”) DECK (METRIC) Given: Triple span continuous, L = 2.4 m each span Deck thickness, t = 0.762 mm L/180 deflection limit (data in tables are based on L/240) Bearing length, n = 50 mm Specified loads 1) Dead loads (DL) a) deck 0.1 kPa b) superimposed 0.4 kPa DL = 0.5 kPa 2) Live load (LL) LL = 2.0 kPa Solution: Strength 1) Specified loads [LL + 0.833 DL] [2.0 + 0.833 (0.5)] = 2.42 kPa 2) Maximum specified load (from Table under “S”) is 2.50 kPa Since 2.50 > 2.42 ∴ ΟΚ 3) Check end web crippling (n = 50 mm) a) Specified end reaction 0.400(2.42)2.4 = 2.32 kN/m b) Maximum specified end reaction (from Section Property Table) Pe = Pe1 + Pe2 n / t Pe = 2.57 + 0.642 50 / 0.762 = 7.77 kN/m Since 7.77 > 2.32 ∴ ΟΚ 4) Check interior web crippling (n = 50 mm) a) Specified interior reaction 1.10(2.42)2.4 = 6.39 kN/m b) Maximum specified interior reaction (from Section Property Table) Pi = Pi1 + Pi2 n / t Web Crippling Check – If n/t > 210, use n/t = 210. Serviceability (Deflection) – The effective moment of inertia for deflection determination has been calculated at an assumed specified live load stress of 0.6Fy. Pi = 4.50 + 0.766 50 / 0.762 = 10.7 kN/m Since 10.7 > 6.39 ∴ ΟΚ Deflection From Table under “D” (L/240) = 2.10 kPa For L/180, multiply 2.10 by 240/180 = 2.8 kPa Since 2.8 is > 2.0 ∴ ΟΚ SECTION PROPERTIES (Per foot of width) IMPERIAL 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 Notes: Coated Steel Thickness (G90) (in.) Coated Weight (psf) 0.030 0.036 0.048 0.060 0.0315 0.0375 0.0495 0.0615 2.16 2.58 3.42 4.26 Sec. Modulus Midspan Support 3 3 (in. ) (in. ) 0.436 0.559 0.769 0.981 0.447 0.564 0.799 0.996 Deflection Moment of Inertia 4 BASE STEEL THICKNESS (inches) 0.030 0.036 0.048 0.060 160 205 282 360 234 293 408 515 136 175 240 306 184 230 321 405 117 151 207 264 147 184 257 324 102 131 180 230 120 150 209 264 90 115 159 202 99 124 172 217 80 102 140 179 82 103 144 181 71 91 125 160 69 87 121 153 64 82 112 143 59 74 103 130 58 74 101 129 51 63 88 111 52 67 92 117 44 55 76 96 48 61 84 107 38 48 66 84 43 56 77 98 33 42 58 73 40 51 70 90 29 37 51 64 37 47 65 83 26 32 45 57 34 44 60 77 23 29 40 51 32 40 56 71 21 26 36 45 29 38 52 66 18 23 32 41 1 2 3 4 Based on ASTM A 653 Grade 33 structural steel. Values in row "S" are based on strength. Values in row "D" are based on deflection of 1/240th span. Web crippling not included in strength calculations. See example. Pe2 End End Pi1 Pi2 Interior Interior (in. ) (lb) (lb) (lb) (lb) 144 216 404 654 36.1 54.0 101 163 273 409 766 1238 46.5 69.5 130 210 BASE STEEL THICKNESS (inches) S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D Specified Web Crippling Data Pe1 0.773 0.967 1.35 1.70 MAXIMUM UNIFORMLY DISTRIBUTED SPECIFIED LOADS (PSF) 1-SPAN 2-SPAN SPAN LENGTH (ft) 6.0 Base Steel Thickness (in.) 0.030 0.036 0.048 0.060 164 207 293 365 562 703 980 1236 140 176 249 311 442 553 771 972 120 152 215 268 354 443 617 778 105 132 187 234 288 360 502 633 92 116 165 206 237 297 414 521 82 103 146 182 198 247 345 435 73 92 130 162 167 208 290 366 65 82 117 146 142 177 247 311 59 74 105 132 121 152 212 267 54 68 96 119 105 131 183 231 49 62 87 109 91 114 159 201 45 56 80 99 80 100 139 175 41 52 73 91 70 88 123 154 38 48 67 84 62 78 108 137 35 44 62 78 55 69 96 121 32 41 58 72 49 62 86 108 30 38 54 67 44 55 77 97 Limit States Design principles were used in accordance with CSA Standard S136-07 3-SPAN BASE STEEL THICKNESS (inches) 0.030 0.036 0.048 0.060 205 258 366 457 443 554 772 973 175 220 312 389 348 435 607 765 151 190 269 336 279 349 486 613 131 165 234 292 227 283 395 498 115 145 206 257 187 234 326 411 102 129 182 228 156 195 271 342 91 115 163 203 131 164 229 288 82 103 146 182 112 139 194 245 74 93 132 164 96 120 167 210 67 84 120 149 83 103 144 182 61 77 109 136 72 90 125 158 56 70 100 124 63 79 110 138 51 65 91 114 55 69 96 122 47 60 84 105 49 61 85 108 44 55 78 97 44 54 76 96 40 51 72 90 39 49 68 85 38 47 67 84 35 44 61 77 GENERAL INFORMATION General Presented in these load tables are maximum uniformly distributed specified loads. Limit States Design (LSD) Strength - Limit States Design principles were used in the development of the load tables in accordance with CSA-S136-07, North American Specification for the Design of Cold Formed Steel Structural Members and the National Building Code of Canada,. The factored resistance under consideration, φR, must be equal to or greater than the effect of the factored loads, i.e., φ R ≥ Effect of Factored Loads. Hence, a short calculation must be carried out to compute the specified live load. See example. Serviceability – Maximum specified deflection loads given in the tables must be compared with their respective specified live loads. Steel Specification - Conforms to ASTM A653M grade 230; Yield strength 230 MPa (33 ksi) and tensile strength of 310 MPa (45 ksi). Finishes – ZF 075 (A25) or Z275 (G90). For heavier galvanizing, refer to ASTM A653-A653M. Design Considerations Strength - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + 0.833 times the specified dead load). Where 0.833 = 1.25/1.5. Conservative Strength Approach - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + specified dead load). EXAMPLE 3” ROOF DECK (IMPERIAL) Given: Two-span continuous, L = 12 ft each span Deck thickness, t = 0.036 in L/180 deflection limit (data in tables are based on L/240) Bearing length, n = 3 in. (n/t = 83.3) Specified loads 1) Dead loads (DL) a) deck 2.6 psf b) superimposed 8.2 psf DL = 10.8 psf 2) Live load (LL) LL = 40 psf Solution: Strength 1) Specified loads [LL + 0.833 DL] [40 + 0.833 (10.8)] = 49.0 psf 2) Maximum specified load (from Table under “S”) is 52 psf Since 52 > 49.0 ∴ ΟΚ 3) Check end web crippling (n = 3 in.) a) Specified end reaction 0.375(49.0)12 = 221 lb/ft b) Maximum specified end reaction (from Section Property Table) Pe = Pe1 + Pe2 n / t Pe = 216 + 54.0 3 / 0.036 = 709 lb/ft Since 709 > 221 ∴ ΟΚ 4) Check interior web crippling (n = 3 in.) a) Specified interior reaction 1.25(49.0)12 = 735 lb/ft b) Maximum specified interior reaction (from Section Property Table) Pi = Pi1 + Pi2 n / t Pi = 409 + 69.5 3 / 0.036 = 1043 lb/ft Since 1043 > 735 ∴ ΟΚ Web Crippling Check – If n/t > 210, use n/t = 210. Serviceability (Deflection) – The effective moment of inertia for deflection determination has been calculated at an assumed specified live load stress of 0.6Fy. Deflection From Table under “D” (L/240) = 88 psf For L/180, multiply 88 by 240/180 = 117 psf. Since 117 is > 40 ∴ ΟΚ SECTION PROPERTIES (Per meter of width) METRIC 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 4.0 4.2 4.4 4.6 4.8 5.0 Notes: 0.762 0.914 1.219 1.524 0.802 0.954 1.26 1.56 Coated Mass 2 (kg/m ) 10.5 12.6 16.7 20.8 Sec. Modulus Midspan Support 3 3 3 3 (10 mm ) (10 mm ) 23.4 30.0 41.3 52.7 24.0 30.3 42.9 53.6 Specified Web Crippling Data Deflection Moment of Inertia 6 4 BASE STEEL THICKNESS (mm) 0.762 6.45 8.56 5.33 6.43 4.48 4.95 3.82 3.90 3.29 3.12 2.87 2.54 2.52 2.09 2.23 1.74 1.99 1.47 1.79 1.25 1.61 1.07 1.46 0.920 1.33 0.800 1.22 0.700 1.12 0.620 1.03 0.550 0.914 1.219 1.524 8.27 11.4 14.6 10.7 14.9 18.9 6.84 9.42 12.0 8.05 11.2 14.2 5.75 7.92 10.1 6.20 8.65 10.9 4.90 6.75 8.61 4.87 6.80 8.58 4.22 5.82 7.42 3.90 5.45 6.87 3.68 5.07 6.47 3.17 4.43 5.58 3.23 4.45 5.68 2.61 3.65 4.60 2.86 3.94 5.03 2.18 3.04 3.84 2.55 3.52 4.49 1.84 2.56 3.23 2.29 3.16 4.03 1.56 2.18 2.75 2.07 2.85 3.64 1.34 1.87 2.36 1.88 2.58 3.30 1.16 1.61 2.04 1.71 2.36 3.01 1.01 1.40 1.77 1.56 2.15 2.75 0.880 1.23 1.55 1.44 1.98 2.53 0.770 1.08 1.36 1.32 1.82 2.33 0.690 0.960 1.21 1 2 3 4 Based on ASTM A 653 Grade 230 structural steel. Values in row "S" are based on strength. Values in row "D" are based on deflection of 1/240th span. Web crippling not included in strength calculations. See example. Pe2 End End Pi1 Pi2 Interior Interior (kN) (kN) (kN) (kN) 1.05 1.32 1.84 2.32 2.13 3.18 5.96 9.64 0.532 0.796 1.49 2.41 4.03 6.04 11.3 18.3 0.686 1.03 1.92 3.10 BASE STEEL THICKNESS (mm) S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D S D Pe1 (10 mm ) MAXIMUM UNIFORMLY DISTRIBUTED SPECIFIED LOADS (kPa) 1-SPAN 2-SPAN SPAN LENGTH (m) 2.0 Base Steel Thickness (mm) Coated Steel Thickness (Z275) (mm) 0.762 0.914 1.219 1.524 6.62 8.35 11.9 14.8 20.6 25.7 35.9 45.2 5.47 6.90 9.79 12.2 15.4 19.3 26.9 34.0 4.60 5.80 8.23 10.3 11.9 14.9 20.8 26.2 3.92 4.94 7.01 8.75 9.35 11.7 16.3 20.6 3.38 4.26 6.05 7.54 7.49 9.37 13.1 16.5 2.94 3.71 5.27 6.57 6.09 7.62 10.6 13.4 2.59 3.26 4.63 5.78 5.02 6.28 8.76 11.0 2.29 2.89 4.10 5.12 4.18 5.23 7.30 9.21 2.04 2.58 3.66 4.56 3.52 4.41 6.15 7.76 1.83 2.31 3.28 4.10 3.00 3.75 5.23 6.59 1.66 2.09 2.96 3.70 2.57 3.21 4.48 5.65 1.50 1.89 2.69 3.35 2.22 2.78 3.87 4.88 1.37 1.73 2.45 3.05 1.93 2.41 3.37 4.25 1.25 1.58 2.24 2.80 1.69 2.11 2.95 3.72 1.15 1.45 2.06 2.57 1.49 1.86 2.59 3.27 1.06 1.34 1.90 2.37 1.31 1.65 2.30 2.89 Limit States Design principles were used in accordance with CSA Standard S136-07 3-SPAN BASE STEEL THICKNESS (mm) 0.762 0.914 1.219 1.524 8.28 10.4 14.8 18.5 16.2 20.2 28.2 35.6 6.84 8.63 12.2 15.3 12.2 15.2 21.2 26.8 5.75 7.25 10.3 12.8 9.36 11.7 16.3 20.6 4.90 6.18 8.76 10.9 7.36 9.21 12.9 16.2 4.22 5.33 7.56 9.43 5.90 7.38 10.3 13.0 3.68 4.64 6.58 8.21 4.79 6.00 8.37 10.6 3.23 4.08 5.79 7.22 3.95 4.94 6.90 8.70 2.86 3.61 5.13 6.40 3.29 4.12 5.75 7.25 2.56 3.22 4.57 5.70 2.77 3.47 4.84 6.11 2.29 2.89 4.10 5.12 2.36 2.95 4.12 5.19 2.07 2.61 3.70 4.62 2.02 2.53 3.53 4.45 1.88 2.37 3.36 4.19 1.75 2.19 3.05 3.85 1.71 2.16 3.06 3.82 1.52 1.90 2.65 3.35 1.57 1.97 2.80 3.49 1.33 1.66 2.32 2.93 1.44 1.81 2.57 3.21 1.17 1.46 2.04 2.58 1.32 1.67 2.37 2.96 1.04 1.30 1.81 2.28 GENERAL INFORMATION General Presented in these load tables are maximum uniformly distributed specified loads. Limit States Design (LSD) Strength - Limit States Design principles were used in the development of the load tables in accordance with CSA-S136-07, North American Specification for the Design of Cold Formed Steel Structural Members and the National Building Code of Canada,. The factored resistance under consideration, φR, must be equal to or greater than the effect of the factored loads, i.e., φ R ≥ Effect of Factored Loads. Hence, a short calculation must be carried out to compute the specified live load. See example. Serviceability – Maximum specified deflection loads given in the tables must be compared with their respective specified live loads. Steel Specification - Conforms to ASTM A653M grade 230; Yield strength 230 MPa (33 ksi) and tensile strength of 310 MPa (45 ksi). Finishes – ZF 075 (A25) or Z275 (G90). For heavier galvanizing, refer to ASTM A653-A653M. Design Considerations Strength - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + 0.833 times the specified dead load). Where 0.833 = 1.25/1.5. Conservative Strength Approach - The maximum uniformly distributed specified load obtained from the load table must be equal to or greater than (Specified live load + specified dead load). EXAMPLE 76 mm (3”) DECK (METRIC) Given: Triple span continuous, L = 3.8 m each span Deck thickness, t = 0.914 mm L/180 deflection limit (data in tables are based on L/240) Bearing length, n = 60 mm (n/t = 65.6) Specified loads 1) Dead loads (DL) a) deck 0.15 kPa b) superimposed 0.85 kPa 1.0 kPa DL = 2) Live load (LL) 2.0 kPa LL = Solution: Strength 1) Specified loads [LL + 0.833 DL] [2.0 + 0.833 (1.0)] = 2.83 kPa 2) Maximum specified load (from Table under “S”) is 2.89 kPa Since 2.89 > 2.83 ∴ ΟΚ 3) Check end web crippling (n = 60 mm) a) Specified end reaction 0.400(2.83)3.8 = 4.30 kN/m b) Maximum specified end reaction (from Section Property Table) Pe = Pe1 + Pe2 n / t Pe = 3.18 + 0.796 60 / 0.914 = 9.63 kN/m Since 9.63 > 4.30 ∴ ΟΚ 4) Check interior web crippling (n = 60 mm) a) Specified interior reaction 1.10(2.83)3.8 = 11.8 kN/m b) Maximum specified interior reaction (from Section Property Table) Pi = Pi1 + Pi2 n / t Web Crippling Check – If n/t > 210, use n/t = 210. Serviceability (Deflection) – The effective moment of inertia for deflection determination has been calculated at an assumed specified live load stress of 0.6Fy. Pi = 6.04 + 1.03 60 / 0.914 = 14.4 kN/m Since 14.4 > 11.8 ∴ ΟΚ Deflection From Table under “D” (L/240) = 2.95 kPa For L/180, multiply 2.95 by 240/180 = 3.93 kPa Since 3.93 is > 2.0 ∴ ΟΚ COMPOSITE SLAB SECTION PROPERTIES (per foot of width) STEEL PROFILE SECTION PROPERTIES (per foot of width) Base Steel Thickness (in.) 0.030 0.036 0.048 Area of Steel Section Modulus Midspan Support Weight G90 (psf) 1.69 2.02 2.67 (in. 2) 0.481 0.577 0.769 (in. 3) 0.189 0.230 0.313 Deflection Inertia Slab Depth, D (in.) 4.0 4.5 5.0 5.5 6.0 (in. 4) 0.167 0.208 0.288 Slab weight (psf) 41.0 47.3 53.5 59.8 66.0 Concrete Volume (yd3/100ft2) 0.95 1.10 1.26 1.41 1.56 (in. 3) 0.193 0.242 0.319 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (psf) Slab Depth, D (in.) Base Steel Thickness (in.) 0.030 0.036 0.048 Slab Span (ft) 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 4.0 4.5 Deck Span 1 500 423 364 317 279 248 223 202 178 156 138 546 467 406 358 318 286 259 236 212 187 165 600 522 461 411 371 337 309 285 264 241 210 2 500 423 364 317 279 248 223 202 178 156 138 546 467 406 358 318 286 259 236 212 187 165 600 522 461 411 371 337 309 285 264 241 210 Deck Span 3 500 423 364 317 279 248 223 202 178 156 138 546 467 406 358 318 286 259 236 212 187 165 600 522 461 411 371 337 309 285 264 241 210 Note: Shoring required at midspan in shaded areas. 1 581 491 422 368 324 289 259 234 212 186 164 634 543 472 415 370 332 301 274 252 224 198 697 607 536 478 431 392 359 331 306 285 259 2 581 491 422 368 324 289 259 234 212 186 164 634 543 472 415 370 332 301 274 252 224 198 697 607 536 478 431 392 359 331 306 285 259 5.5 5.0 Deck Span 3 581 491 422 368 324 289 259 234 212 186 164 634 543 472 415 370 332 301 274 252 224 198 697 607 536 478 431 392 359 331 306 285 259 1 662 560 481 419 369 329 295 267 243 216 191 722 618 537 473 421 379 343 313 287 261 231 795 691 610 545 491 447 409 377 349 325 304 2 662 560 481 419 369 329 295 267 243 216 191 722 618 537 473 421 379 343 313 287 261 231 795 691 610 545 491 447 409 377 349 325 304 6.0 Deck Span 3 662 560 481 419 369 329 295 267 243 216 191 722 618 537 473 421 379 343 313 287 261 231 795 691 610 545 491 447 409 377 349 325 304 1 743 628 540 470 414 369 331 299 272 246 217 810 694 603 531 473 425 385 351 322 297 264 892 776 685 611 551 501 459 423 392 365 341 2 743 628 540 470 414 369 331 299 272 246 217 810 694 603 531 473 425 385 351 322 297 264 892 776 685 611 551 501 459 423 392 365 341 Deck Span 3 743 628 540 470 414 369 331 299 272 246 217 810 694 603 531 473 425 385 351 322 297 264 892 776 685 611 551 501 459 423 392 365 341 1 823 696 599 521 459 409 367 332 302 276 244 898 769 669 589 524 471 427 389 357 329 297 989 860 759 678 611 556 509 469 434 404 378 2 823 696 599 521 459 409 367 332 302 276 244 898 769 669 589 524 471 427 389 357 329 297 989 860 759 678 611 556 509 469 434 404 378 3 823 696 599 521 459 409 367 332 302 276 244 898 769 669 589 524 471 427 389 357 329 297 989 860 759 678 611 556 509 469 434 404 378 TECHNICAL NOTES Material Properties 1. The composite steel deck ICD-150 is the IRD-150 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-01 (Supplement 2004). 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-150 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-03. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-06. To establish the shear-bond capacity of the composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-02. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Imperial) Determine the specified uniformly distributed live load that can be placed on the composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.048 in. Yield strength = 33 ksi 3 Normal density concrete = 145 lb/ft Overall slab depth = 4.5 in. Double span, each = 10 ft Specified superimposed dead load, DL = 32 psf Solution: The maximum specified load in (psf) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 10 ft span, the maximum specified load is 259 psf, therefore, 259 ≥ [LL + (1.25/1.5)32] and solving for LL, LL = 232 psf Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 2.25”. -At middle support use n=4”. COMPOSITE SLAB SECTION PROPERTIES (per metre of width) STEEL PROFILE SECTION PROPERTIES (per metre of width) Base Steel Thickness (mm) 0.762 0.914 1.22 Area of Steel Mass Z275 (mm 2) 1017 1221 1628 (kg/m 2) 8.26 9.86 13.1 Section Modulus Midspan Support (x103mm 3) 10.2 12.4 16.9 (x103mm 3) 10.4 13.0 17.2 Deflection Inertia Slab Depth, D (mm) 100 110 120 130 140 (x106mm 4) 0.236 0.293 0.397 Slab weight (kPa) 1.88 2.11 2.33 2.56 2.78 Concrete Volume (m 3/10m 2) 0.76 0.86 0.96 1.06 1.16 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (kPa) Slab Depth, D (mm) Base Steel Thickness (mm) 0.762 0.914 1.22 Slab Span (m) 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 100 110 Deck Span 1 24.2 21.6 17.6 14.6 12.4 10.8 10.0 9.4 8.0 6.8 5.8 26.2 23.6 19.5 16.5 14.2 12.4 11.7 11.0 9.5 8.1 6.9 28.8 26.2 22.1 19.0 16.6 14.8 14.0 13.3 12.0 9.9 8.2 2 24.2 21.6 17.6 14.6 12.4 10.8 10.0 9.4 8.0 6.8 5.8 26.2 23.6 19.5 16.5 14.2 12.4 11.7 11.0 9.5 8.1 6.9 28.8 26.2 22.1 19.0 16.6 14.8 14.0 13.3 12.0 9.9 8.2 120 Deck Span 3 24.2 21.6 17.6 14.6 12.4 10.8 10.0 9.4 8.0 6.8 5.8 26.2 23.6 19.5 16.5 14.2 12.4 11.7 11.0 9.5 8.1 6.9 28.8 26.2 22.1 19.0 16.6 14.8 14.0 13.3 12.0 9.9 8.2 Note: Shoring required at midspan in shaded areas. 1 27.3 24.4 19.8 16.5 14.1 12.1 11.3 10.6 9.2 7.8 6.7 29.6 26.6 22.0 18.6 16.1 14.0 13.2 12.4 11.0 9.4 8.1 32.5 29.6 24.9 21.5 18.8 16.7 15.8 15.0 13.6 12.2 10.5 2 27.3 24.4 19.8 16.5 14.1 12.1 11.3 10.6 9.2 7.8 6.7 29.6 26.6 22.0 18.6 16.1 14.0 13.2 12.4 11.0 9.4 8.1 32.5 29.6 24.9 21.5 18.8 16.7 15.8 15.0 13.6 12.2 10.5 130 Deck Span 3 27.3 24.4 19.8 16.5 14.1 12.1 11.3 10.6 9.2 7.8 6.7 29.6 26.6 22.0 18.6 16.1 14.0 13.2 12.4 11.0 9.4 8.1 32.5 29.6 24.9 21.5 18.8 16.7 15.8 15.0 13.6 12.2 10.5 1 30.4 27.2 22.1 18.4 15.7 13.5 12.7 11.9 10.5 8.9 7.6 33.0 29.7 24.6 20.8 17.9 15.7 14.7 13.9 12.4 10.7 9.2 36.2 33.0 27.8 24.0 21.0 18.6 17.6 16.7 15.1 13.8 12.1 2 30.4 27.2 22.1 18.4 15.7 13.5 12.7 11.9 10.5 8.9 7.6 33.0 29.7 24.6 20.8 17.9 15.7 14.7 13.9 12.4 10.7 9.2 36.2 33.0 27.8 24.0 21.0 18.6 17.6 16.7 15.1 13.8 12.1 140 Deck Span 3 30.4 27.2 22.1 18.4 15.7 13.5 12.7 11.9 10.5 8.9 7.6 33.0 29.7 24.6 20.8 17.9 15.7 14.7 13.9 12.4 10.7 9.2 36.2 33.0 27.8 24.0 21.0 18.6 17.6 16.7 15.1 13.8 12.1 1 33.6 30.0 24.4 20.3 17.3 14.9 14.0 13.1 11.6 10.0 8.5 36.4 32.8 27.1 22.9 19.7 17.3 16.2 15.3 13.7 12.0 10.3 40.0 36.4 30.7 26.4 23.1 20.5 19.4 18.4 16.7 15.2 13.6 2 33.6 30.0 24.4 20.3 17.3 14.9 14.0 13.1 11.6 10.0 8.5 36.4 32.8 27.1 22.9 19.7 17.3 16.2 15.3 13.7 12.0 10.3 40.0 36.4 30.7 26.4 23.1 20.5 19.4 18.4 16.7 15.2 13.6 Deck Span 3 33.6 30.0 24.4 20.3 17.3 14.9 14.0 13.1 11.6 10.0 8.5 36.4 32.8 27.1 22.9 19.7 17.3 16.2 15.3 13.7 12.0 10.3 40.0 36.4 30.7 26.4 23.1 20.5 19.4 18.4 16.7 15.2 13.6 1 36.7 32.8 26.7 22.2 18.9 16.3 15.3 14.3 12.7 11.0 9.4 39.8 35.8 29.6 25.1 21.6 18.9 17.7 16.7 15.0 13.3 11.4 43.7 39.8 33.5 28.9 25.3 22.5 21.3 20.2 18.3 16.7 15.2 2 36.7 32.8 26.7 22.2 18.9 16.3 15.3 14.3 12.7 11.0 9.4 39.8 35.8 29.6 25.1 21.6 18.9 17.7 16.7 15.0 13.3 11.4 43.7 39.8 33.5 28.9 25.3 22.5 21.3 20.2 18.3 16.7 15.2 3 36.7 32.8 26.7 22.2 18.9 16.3 15.3 14.3 12.7 11.0 9.4 39.8 35.8 29.6 25.1 21.6 18.9 17.7 16.7 15.0 13.3 11.4 43.7 39.8 33.5 28.9 25.3 22.5 21.3 20.2 18.3 16.7 15.2 TECHNICAL NOTES Material Properties 1. The composite steel deck ICD-150 is the IRD-150 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-01 (Supplement 2004). 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-150 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-03. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-06. To establish the shear-bond capacity of the composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-02. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Metric) Determine the specified uniformly distributed live load that can be placed on the composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 1.22 mm Yield strength = 230 MPa 3 Normal density concrete = 2300 kg/m Overall slab depth = 120 mm Double span, each = 3.0 m Specified superimposed dead load, DL = 1.55 kPa Solution: The maximum specified load in (kPa) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 3.0 m span, the maximum specified load is 13.8 kPa, therefore, 13.8 ≥ [LL + (1.25/1.5)1.55] and solving for LL, LL = 12.5 kPa Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 57mm -At middle support use n=100mm. COMPOSITE SLAB SECTION PROPERTIES (per foot of width) STEEL PROFILE SECTION PROPERTIES (per foot of width) Base Steel Thickness (in.) 0.030 0.036 0.048 Area of Steel Section Modulus Midspan Support Weight G90 (psf) 1.69 2.02 2.67 (in. 2) 0.481 0.577 0.769 (in. 3) 0.193 0.242 0.319 Deflection Inertia Slab Depth, D (in.) 4.0 4.5 5.0 5.5 6.0 (in. 4) 0.183 0.219 0.291 Slab weight (psf) 45.5 51.8 58.0 64.3 70.5 Concrete Volume (yd3/100ft2) 1.06 1.21 1.37 1.52 1.68 (in. 3) 0.189 0.230 0.313 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (psf) Slab Depth, D (in.) Base Steel Thickness (in.) 0.030 0.036 0.048 Slab Span (ft) 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 5'- 0" 5'- 6" 6'- 0" 6'- 6" 7'- 0" 7'- 6" 8'- 0" 8'- 6" 9'- 0" 9'- 6" 10'- 0" 4.0 4.5 Deck Span 5.5 5.0 Deck Span Deck Span 6.0 Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 401 338 290 252 221 196 176 159 144 132 121 401 338 290 252 221 196 176 159 144 132 121 401 338 290 252 221 196 176 159 144 132 121 461 389 333 289 254 226 202 182 165 151 139 461 389 333 289 254 226 202 182 165 151 139 461 389 333 289 254 226 202 182 165 151 139 520 439 376 327 287 255 228 206 187 171 157 520 439 376 327 287 255 228 206 187 171 157 520 439 376 327 287 255 228 206 187 171 157 580 489 419 364 320 284 254 229 208 190 174 580 489 419 364 320 284 254 229 208 190 174 580 489 419 364 320 284 254 229 208 190 174 639 539 462 401 353 313 280 253 229 210 192 639 539 462 401 353 313 280 253 229 210 192 639 539 462 401 353 313 280 253 229 210 192 454 383 328 285 251 223 199 180 163 149 137 454 383 328 285 251 223 199 180 163 149 137 454 383 328 285 251 223 199 180 163 149 137 521 440 377 328 288 256 229 207 188 171 157 521 440 377 328 288 256 229 207 188 171 157 521 440 377 328 288 256 229 207 188 171 157 589 497 426 370 325 289 259 233 212 194 178 589 497 426 370 325 289 259 233 212 194 178 589 497 426 370 325 289 259 233 212 194 178 656 554 475 412 363 322 288 260 236 216 198 656 554 475 412 363 322 288 260 236 216 198 656 554 475 412 363 322 288 260 236 216 198 724 610 523 455 400 355 318 287 260 238 218 724 610 523 455 400 355 318 287 260 238 218 724 610 523 455 400 355 318 287 260 238 218 535 452 387 337 296 263 236 213 193 177 162 535 452 387 337 296 263 236 213 193 177 162 535 452 387 337 296 263 236 213 193 177 162 615 519 445 387 340 302 271 244 222 203 186 615 519 445 387 340 302 271 244 222 203 186 615 519 445 387 340 302 271 244 222 203 186 694 586 503 437 384 341 306 276 251 229 211 694 586 503 437 384 341 306 276 251 229 211 694 586 503 437 384 341 306 276 251 229 211 774 653 560 487 428 380 341 308 280 255 235 774 653 560 487 428 380 341 308 280 255 235 774 653 560 487 428 380 341 308 280 255 235 853 720 618 537 472 420 376 339 308 282 259 853 720 618 537 472 420 376 339 308 282 259 853 720 618 537 472 420 376 339 308 282 259 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The ICD-150 (INVERTED) is the IRD-150 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-150 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-03. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-06. To establish the shear-bond capacity of the IDEAL inverted composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-02. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Imperial) Determine the specified uniformly distributed live load that can be placed on the IDEAL inverted composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.048 in. Yield strength = 33 ksi 3 Normal density concrete = 145 lb/ft Overall slab depth = 5.0 in. Double span, each = 9.5 ft Specified superimposed dead load, DL = 37 psf Solution: The maximum specified load in (psf) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 9.5 ft span, the maximum specified load is 229 psf, therefore, 229 ≥ [LL + (1.25/1.5)32] and solving for LL, LL = 198 psf Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 2.25”. -At middle support use n=4”. COMPOSITE SLAB SECTION PROPERTIES (per metre of width) STEEL PROFILE SECTION PROPERTIES (per metre of width) Base Steel Thickness (mm) 0.762 0.914 1.22 Area of Steel Mass Z275 (mm 2) 1017 1221 1628 (kg/m 2) 8.26 9.86 13.1 Section Modulus Midspan Support (x103mm 3) 10.4 13.0 17.2 (x103mm 3) 10.2 12.4 16.9 Deflection Inertia Slab Depth, D (mm) 100 110 120 130 140 (x106mm 4) 0.250 0.299 0.397 Slab weight (kPa) 2.06 2.28 2.51 2.73 2.96 Concrete Volume (m 3/10m 2) 0.86 0.96 1.06 1.16 1.26 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (kPa) Slab Depth, D (mm) Base Steel Thickness (mm) 0.762 0.914 1.22 Slab Span (m) 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 1.5 1.6 1.8 2.0 2.2 2.4 2.5 2.6 2.8 3.0 3.2 100 110 Deck Span 120 Deck Span 130 Deck Span 140 Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 19.4 17.3 14.0 11.6 9.9 8.5 7.9 7.4 6.5 5.8 5.2 19.4 17.3 14.0 11.6 9.9 8.5 7.9 7.4 6.5 5.8 5.2 19.4 17.3 14.0 11.6 9.9 8.5 7.9 7.4 6.5 5.8 5.2 21.7 19.3 15.7 13.0 11.0 9.5 8.9 8.3 7.3 6.5 5.9 21.7 19.3 15.7 13.0 11.0 9.5 8.9 8.3 7.3 6.5 5.9 21.7 19.3 15.7 13.0 11.0 9.5 8.9 8.3 7.3 6.5 5.9 24.0 21.4 17.3 14.4 12.2 10.5 9.8 9.2 8.1 7.2 6.5 24.0 21.4 17.3 14.4 12.2 10.5 9.8 9.2 8.1 7.2 6.5 24.0 21.4 17.3 14.4 12.2 10.5 9.8 9.2 8.1 7.2 6.5 26.3 23.4 19.0 15.8 13.4 11.5 10.7 10.1 8.9 7.9 7.1 26.3 23.4 19.0 15.8 13.4 11.5 10.7 10.1 8.9 7.9 7.1 26.3 23.4 19.0 15.8 13.4 11.5 10.7 10.1 8.9 7.9 7.1 28.6 25.5 20.7 17.2 14.6 12.5 11.7 10.9 9.6 8.6 7.7 28.6 25.5 20.7 17.2 14.6 12.5 11.7 10.9 9.6 8.6 7.7 28.6 25.5 20.7 17.2 14.6 12.5 11.7 10.9 9.6 8.6 7.7 21.9 19.5 15.9 13.2 11.2 9.6 9.0 8.4 7.4 6.6 5.9 21.9 19.5 15.9 13.2 11.2 9.6 9.0 8.4 7.4 6.6 5.9 21.9 19.5 15.9 13.2 11.2 9.6 9.0 8.4 7.4 6.6 5.9 24.5 21.9 17.7 14.7 12.5 10.8 10.0 9.4 8.3 7.4 6.6 24.5 21.9 17.7 14.7 12.5 10.8 10.0 9.4 8.3 7.4 6.6 24.5 21.9 17.7 14.7 12.5 10.8 10.0 9.4 8.3 7.4 6.6 27.1 24.2 19.6 16.3 13.8 11.9 11.1 10.4 9.2 8.2 7.4 27.1 24.2 19.6 16.3 13.8 11.9 11.1 10.4 9.2 8.2 7.4 27.1 24.2 19.6 16.3 13.8 11.9 11.1 10.4 9.2 8.2 7.4 29.8 26.5 21.5 17.9 15.2 13.1 12.2 11.4 10.1 9.0 8.1 29.8 26.5 21.5 17.9 15.2 13.1 12.2 11.4 10.1 9.0 8.1 29.8 26.5 21.5 17.9 15.2 13.1 12.2 11.4 10.1 9.0 8.1 32.4 28.8 23.4 19.5 16.5 14.2 13.3 12.4 10.9 9.8 8.8 32.4 28.8 23.4 19.5 16.5 14.2 13.3 12.4 10.9 9.8 8.8 32.4 28.8 23.4 19.5 16.5 14.2 13.3 12.4 10.9 9.8 8.8 25.9 23.1 18.7 15.6 13.2 11.4 10.6 9.9 8.8 7.8 7.0 25.9 23.1 18.7 15.6 13.2 11.4 10.6 9.9 8.8 7.8 7.0 25.9 23.1 18.7 15.6 13.2 11.4 10.6 9.9 8.8 7.8 7.0 29.0 25.8 21.0 17.4 14.8 12.7 11.9 11.1 9.8 8.8 7.9 29.0 25.8 21.0 17.4 14.8 12.7 11.9 11.1 9.8 8.8 7.9 29.0 25.8 21.0 17.4 14.8 12.7 11.9 11.1 9.8 8.8 7.9 32.0 28.6 23.2 19.3 16.4 14.1 13.1 12.3 10.9 9.7 8.7 32.0 28.6 23.2 19.3 16.4 14.1 13.1 12.3 10.9 9.7 8.7 32.0 28.6 23.2 19.3 16.4 14.1 13.1 12.3 10.9 9.7 8.7 35.1 31.3 25.4 21.1 17.9 15.5 14.4 13.5 11.9 10.6 9.6 35.1 31.3 25.4 21.1 17.9 15.5 14.4 13.5 11.9 10.6 9.6 35.1 31.3 25.4 21.1 17.9 15.5 14.4 13.5 11.9 10.6 9.6 38.2 34.1 27.7 23.0 19.5 16.8 15.7 14.7 13.0 11.6 10.4 38.2 34.1 27.7 23.0 19.5 16.8 15.7 14.7 13.0 11.6 10.4 38.2 34.1 27.7 23.0 19.5 16.8 15.7 14.7 13.0 11.6 10.4 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The ICD-150 (INVERTED) is the IRD-150 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-150 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-03. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-06. To establish the shear-bond capacity of the IDEAL inverted composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-02. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Metric) Determine the specified uniformly distributed live load that can be placed on the IDEAL inverted composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 1.22 mm Yield strength = 230 MPa 3 Normal density concrete = 2300 kg/m Overall slab depth = 130 mm Double span, each = 2.8 m Specified superimposed dead load, DL = 1.70 kPa Solution: The maximum specified load in (kPa) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 2.8 m span, the maximum specified load is 11.9 kPa, therefore, 11.9 ≥ [LL + (1.25/1.5)1.70] and solving for LL, LL = 10.5 kPa Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 57mm -At middle support use n=100mm. STEEL DECK SECTION PROPERTIES Base Steel Thickness (in.) 0.030 0.036 0.048 0.060 Area of Steel (in2 ) 0.617 0.741 0.987 1.23 (per foot of width) Weight Section Modulus G90 Midspan Support (in3 ) (in3 ) (psf) 2.16 0.436 0.447 2.58 0.559 0.564 3.42 0.769 0.799 4.26 0.981 0.996 COMPOSITE SLAB INFORMATION (per foot of width) Deflection Inertia (in4 ) 0.773 0.967 1.35 1.70 Slab Depth, D (in.) 5.0 5.5 Slab weight (psf) 44.4 50.6 3 6.0 6.5 7.0 56.9 63.1 69.4 1.45 1.61 2 Concrete Volume (yd /100ft ) 0.99 1.15 1.30 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (psf) Slab Depth, D (in.) Base Steel Slab Thickness Span (in.) (ft) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 0.030 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 0.036 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 0.048 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 0.060 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 5.0 5.5 Deck Span 6.0 Deck Span 6.5 Deck Span 7.0 Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 307 260 223 194 169 149 132 118 106 96 87 79 265 231 204 181 162 145 132 120 109 100 92 85 268 240 216 196 179 163 150 139 129 120 112 105 268 239 216 196 178 163 150 139 129 120 112 104 98 307 260 223 194 169 149 132 118 106 96 87 79 265 231 204 181 162 145 132 120 109 100 92 85 268 240 216 196 179 163 150 139 129 120 112 105 268 239 216 196 178 163 150 139 129 120 112 104 98 307 260 223 194 169 149 132 118 106 96 87 79 265 231 204 181 162 145 132 120 109 100 92 85 268 240 216 196 179 163 150 139 129 120 112 105 268 239 216 196 178 163 150 139 129 120 112 104 98 353 299 257 223 195 172 152 136 122 110 100 91 305 266 235 208 186 167 151 138 126 115 106 98 309 276 249 226 206 188 173 160 148 138 129 120 308 276 248 225 205 188 173 160 148 138 129 120 113 353 299 257 223 195 172 152 136 122 110 100 91 305 266 235 208 186 167 151 138 126 115 106 98 309 276 249 226 206 188 173 160 148 138 129 120 308 276 248 225 205 188 173 160 148 138 129 120 113 353 299 257 223 195 172 152 136 122 110 100 91 305 266 235 208 186 167 151 138 126 115 106 98 309 276 249 226 206 188 173 160 148 138 129 120 308 276 248 225 205 188 173 160 148 138 129 120 113 400 339 291 252 220 194 173 154 138 125 113 103 345 301 265 236 211 189 171 156 142 130 120 111 349 313 282 255 233 213 196 181 168 156 146 136 349 312 281 255 232 213 196 181 168 156 145 136 128 400 339 291 252 220 194 173 154 138 125 113 103 345 301 265 236 211 189 171 156 142 130 120 111 349 313 282 255 233 213 196 181 168 156 146 136 349 312 281 255 232 213 196 181 168 156 145 136 128 400 339 291 252 220 194 173 154 138 125 113 103 345 301 265 236 211 189 171 156 142 130 120 111 349 313 282 255 233 213 196 181 168 156 146 136 349 312 281 255 232 213 196 181 168 156 145 136 128 446 378 324 281 246 217 193 172 154 139 126 115 385 336 296 263 235 211 191 174 159 145 134 124 390 349 314 285 260 238 219 202 187 174 163 152 389 348 314 285 259 238 218 202 187 174 162 152 143 446 378 324 281 246 217 193 172 154 139 126 115 385 336 296 263 235 211 191 174 159 145 134 124 390 349 314 285 260 238 219 202 187 174 163 152 389 348 314 285 259 238 218 202 187 174 162 152 143 446 378 324 281 246 217 193 172 154 139 126 115 385 336 296 263 235 211 191 174 159 145 134 124 390 349 314 285 260 238 219 202 187 174 163 152 389 348 314 285 259 238 218 202 187 174 162 152 143 492 417 358 311 272 239 213 190 170 154 139 127 425 371 327 290 260 233 211 192 175 161 148 136 430 385 347 315 287 263 242 223 207 192 180 168 430 385 347 314 286 262 241 223 207 192 179 168 158 492 417 358 311 272 239 213 190 170 154 139 127 425 371 327 290 260 233 211 192 175 161 148 136 430 385 347 315 287 263 242 223 207 192 180 168 430 385 347 314 286 262 241 223 207 192 179 168 158 492 417 358 311 272 239 213 190 170 154 139 127 425 371 327 290 260 233 211 192 175 161 148 136 430 385 347 315 287 263 242 223 207 192 180 168 430 385 347 314 286 262 241 223 207 192 179 168 158 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The composite steel deck ICD-300 is the IRD-300 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-300 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-08. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-08. To establish the shear-bond capacity of the ICD300 composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-08. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Imperial) Determine the specified uniformly distributed live load that can be placed on the composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.036 in. Yield strength = 33 ksi 3 Normal density concrete = 145 lb/ft Overall slab depth = 6 in. Double span, each = 11 ft Specified superimposed dead load, DL = 32 psf Solution: The maximum specified load in (psf) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 11 ft span, the maximum specified load is 142 psf, therefore, 142 ≥ [LL + (1.25/1.5)32] and solving for LL, LL = 99 psf Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 4.5”. -At middle support use n=6”. STEEL DECK SECTION PROPERTIES Base Steel Thickness (mm) 0.762 0.914 1.219 1.524 Area of Steel (mm2 ) 1306 1568 2090 2613 COMPOSITE SLAB INFORMATION (per metre of width) Mass Section Modulus Deflection Z275 Midspan Support Inertia (kg/m2 ) (x103 mm3 ) (x103mm3) (x106 mm4) 10.5 23.4 24.0 1.05 12.6 30.0 30.3 1.32 16.7 41.3 42.9 1.84 20.8 52.7 53.6 2.32 (per metre of width) Slab Depth, D (mm) 130 140 150 160 Slab weight (kPa) 2.11 2.34 2.56 2.79 3 170 3.01 2 Concrete Volume (m /10m ) 0.85 0.95 1.05 1.15 1.25 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (kPa) Slab Depth, D (mm) Base Steel Slab Thickness Span (mm) (m) 2.2 2.4 2.5 2.6 2.8 3.0 0.762 3.2 3.4 3.5 3.6 3.8 4.0 2.2 2.4 2.5 2.6 2.8 3.0 0.914 3.2 3.4 3.5 3.6 3.8 4.0 2.5 2.6 2.8 3.0 3.2 3.4 1.219 3.5 3.6 3.8 4.0 4.2 4.4 2.6 2.8 3.0 3.2 3.4 3.5 3.6 1.524 3.8 4.0 4.2 4.4 4.5 4.6 130 140 Deck Span 150 Deck Span 160 Deck Span 170 Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 10.4 8.6 7.9 7.3 6.3 5.4 4.7 4.2 3.9 3.7 3.3 3.0 12.4 10.4 9.6 8.9 7.7 6.7 5.9 5.3 5.0 4.7 4.2 3.8 12.7 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 4.4 4.3 10.4 8.6 7.9 7.3 6.3 5.4 4.7 4.2 3.9 3.7 3.3 3.0 12.4 10.4 9.6 8.9 7.7 6.7 5.9 5.3 5.0 4.7 4.2 3.8 12.7 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 4.4 4.3 10.4 8.6 7.9 7.3 6.3 5.4 4.7 4.2 3.9 3.7 3.3 3.0 12.4 10.4 9.6 8.9 7.7 6.7 5.9 5.3 5.0 4.7 4.2 3.8 12.7 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 11.8 10.3 9.1 8.1 7.3 6.9 6.6 6.0 5.4 5.0 4.6 4.4 4.3 11.5 9.6 8.9 8.2 7.0 6.1 5.3 4.6 4.4 4.1 3.7 3.3 13.8 11.6 10.7 9.9 8.6 7.5 6.6 5.9 5.5 5.2 4.7 4.3 14.1 13.2 11.5 10.2 9.0 8.1 7.7 7.3 6.7 6.1 5.6 5.1 13.1 11.5 10.1 9.0 8.1 7.7 7.3 6.6 6.1 5.6 5.1 4.9 4.8 11.5 9.6 8.9 8.2 7.0 6.1 5.3 4.6 4.4 4.1 3.7 3.3 13.8 11.6 10.7 9.9 8.6 7.5 6.6 5.9 5.5 5.2 4.7 4.3 14.1 13.2 11.5 10.2 9.0 8.1 7.7 7.3 6.7 6.1 5.6 5.1 13.1 11.5 10.1 9.0 8.1 7.7 7.3 6.6 6.1 5.6 5.1 4.9 4.8 11.5 9.6 8.9 8.2 7.0 6.1 5.3 4.6 4.4 4.1 3.7 3.3 13.8 11.6 10.7 9.9 8.6 7.5 6.6 5.9 5.5 5.2 4.7 4.3 14.1 13.2 11.5 10.2 9.0 8.1 7.7 7.3 6.7 6.1 5.6 5.1 13.1 11.5 10.1 9.0 8.1 7.7 7.3 6.6 6.1 5.6 5.1 4.9 4.8 12.7 10.6 9.8 9.0 7.7 6.7 5.8 5.1 4.8 4.5 4.1 3.6 15.2 12.8 11.8 11.0 9.5 8.3 7.3 6.5 6.1 5.8 5.2 4.7 15.6 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.2 5.7 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.1 5.7 5.4 5.2 12.7 10.6 9.8 9.0 7.7 6.7 5.8 5.1 4.8 4.5 4.1 3.6 15.2 12.8 11.8 11.0 9.5 8.3 7.3 6.5 6.1 5.8 5.2 4.7 15.6 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.2 5.7 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.1 5.7 5.4 5.2 12.7 10.6 9.8 9.0 7.7 6.7 5.8 5.1 4.8 4.5 4.1 3.6 15.2 12.8 11.8 11.0 9.5 8.3 7.3 6.5 6.1 5.8 5.2 4.7 15.6 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.2 5.7 14.5 12.7 11.2 10.0 8.9 8.5 8.1 7.3 6.7 6.1 5.7 5.4 5.2 13.9 11.6 10.7 9.8 8.4 7.3 6.4 5.6 5.3 5.0 4.4 4.0 16.6 14.0 12.9 12.0 10.4 9.0 8.0 7.1 6.7 6.3 5.7 5.2 17.1 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 6.0 5.7 13.9 11.6 10.7 9.8 8.4 7.3 6.4 5.6 5.3 5.0 4.4 4.0 16.6 14.0 12.9 12.0 10.4 9.0 8.0 7.1 6.7 6.3 5.7 5.2 17.1 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 6.0 5.7 13.9 11.6 10.7 9.8 8.4 7.3 6.4 5.6 5.3 5.0 4.4 4.0 16.6 14.0 12.9 12.0 10.4 9.0 8.0 7.1 6.7 6.3 5.7 5.2 17.1 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 15.9 13.9 12.2 10.9 9.8 9.3 8.8 8.0 7.3 6.7 6.2 6.0 5.7 15.1 12.6 11.6 10.7 9.2 7.9 6.9 6.1 5.7 5.4 4.8 4.3 18.1 15.2 14.0 13.0 11.2 9.8 8.7 7.7 7.3 6.9 6.2 5.6 18.5 17.2 15.1 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 17.2 15.0 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 6.5 6.2 15.1 12.6 11.6 10.7 9.2 7.9 6.9 6.1 5.7 5.4 4.8 4.3 18.1 15.2 14.0 13.0 11.2 9.8 8.7 7.7 7.3 6.9 6.2 5.6 18.5 17.2 15.1 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 17.2 15.0 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 6.5 6.2 15.1 12.6 11.6 10.7 9.2 7.9 6.9 6.1 5.7 5.4 4.8 4.3 18.1 15.2 14.0 13.0 11.2 9.8 8.7 7.7 7.3 6.9 6.2 5.6 18.5 17.2 15.1 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 17.2 15.0 13.3 11.8 10.6 10.1 9.6 8.7 8.0 7.3 6.7 6.5 6.2 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The composite steel deck ICD-300 is the IRD-300 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-300 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-08. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-08. To establish the shear-bond capacity of the ICD300 composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-08. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Metric) Determine the specified uniformly distributed live load that can be placed on the composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.914 mm Yield strength = 230 MPa 3 Normal density concrete = 2300 kg/m Overall slab depth = 150 mm Double span, each = 3.5 m Specified superimposed dead load, DL = 1.60 kPa Solution: The maximum specified load in (kPa) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 3.5 m span, the maximum specified load is 6.1 kPa, therefore, 6.1 ≥ [LL + (1.25/1.5)1.55] and solving for LL, LL = 4.77 kPa Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 114mm. -At middle support use n=150mm. STEEL DECK SECTION PROPERTIES Base Steel Thickness (in.) 0.030 0.036 0.048 0.060 Area of Steel 2 (in ) 0.617 0.741 0.987 1.23 (per foot of width) Weight Section Modulus G90 Midspan Support 3 3 (in ) (in ) (psf) 2.16 0.447 0.436 2.58 0.564 0.559 3.42 0.799 0.769 4.26 0.996 0.981 COMPOSITE SLAB INFORMATION (per foot of width) Deflection Inertia 4 (in ) 0.841 1.02 1.36 1.70 Slab Depth, D (in.) 5.0 5.5 Slab weight (psf) 51.7 57.9 6.0 6.5 7.0 64.2 70.4 76.7 1.63 1.79 3 2 Concrete Volume (yd /100ft ) 1.17 1.33 1.48 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (psf) Slab Depth, D (in.) Base Steel Slab Thickness Span (in.) (ft) 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 0.030 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 0.036 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 0.048 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 0.060 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 5.0 5.5 Deck Span 6.0 Deck Span 6.5 7.0 Deck Span Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 367 308 261 224 193 168 148 130 115 103 92 82 295 255 222 195 172 153 137 123 111 100 91 83 275 244 218 196 177 161 146 134 123 114 105 98 275 244 218 196 177 160 146 134 123 114 105 98 91 367 308 261 224 193 168 148 130 115 103 92 82 295 255 222 195 172 153 137 123 111 100 91 83 275 244 218 196 177 161 146 134 123 114 105 98 275 244 218 196 177 160 146 134 123 114 105 98 91 367 308 261 224 193 168 148 130 115 103 92 82 295 255 222 195 172 153 137 123 111 100 91 83 275 244 218 196 177 161 146 134 123 114 105 98 275 244 218 196 177 160 146 134 123 114 105 98 91 418 350 297 254 220 191 168 148 131 117 104 94 336 290 252 221 196 174 156 140 126 114 104 95 313 278 248 223 201 183 167 152 140 129 120 111 313 277 247 222 201 182 166 152 140 129 119 111 103 418 350 297 254 220 191 168 148 131 117 104 94 336 290 252 221 196 174 156 140 126 114 104 95 313 278 248 223 201 183 167 152 140 129 120 111 313 277 247 222 201 182 166 152 140 129 119 111 103 418 350 297 254 220 191 168 148 131 117 104 94 336 290 252 221 196 174 156 140 126 114 104 95 313 278 248 223 201 183 167 152 140 129 120 111 313 277 247 222 201 182 166 152 140 129 119 111 103 468 392 333 285 246 214 188 166 147 131 117 105 376 325 283 248 219 195 174 156 141 128 116 106 351 311 278 249 225 205 187 171 157 145 134 124 350 311 277 249 225 204 186 171 157 145 134 124 116 468 392 333 285 246 214 188 166 147 131 117 105 376 325 283 248 219 195 174 156 141 128 116 106 351 311 278 249 225 205 187 171 157 145 134 124 350 311 277 249 225 204 186 171 157 145 134 124 116 468 392 333 285 246 214 188 166 147 131 117 105 376 325 283 248 219 195 174 156 141 128 116 106 351 311 278 249 225 205 187 171 157 145 134 124 350 311 277 249 225 204 186 171 157 145 134 124 116 518 434 368 316 273 237 208 183 163 145 129 116 416 359 313 275 243 216 193 173 156 142 129 118 388 344 307 276 249 226 206 189 174 160 148 138 388 344 307 276 249 226 206 189 174 160 148 138 128 518 434 368 316 273 237 208 183 163 145 129 116 416 359 313 275 243 216 193 173 156 142 129 118 388 344 307 276 249 226 206 189 174 160 148 138 388 344 307 276 249 226 206 189 174 160 148 138 128 518 434 368 316 273 237 208 183 163 145 129 116 416 359 313 275 243 216 193 173 156 142 129 118 388 344 307 276 249 226 206 189 174 160 148 138 388 344 307 276 249 226 206 189 174 160 148 138 128 568 476 404 346 299 260 228 201 178 159 142 127 457 394 343 301 266 237 212 190 172 155 141 129 426 378 337 303 274 248 226 207 191 176 163 151 426 377 337 303 273 248 226 207 191 176 163 151 141 568 476 404 346 299 260 228 201 178 159 142 127 457 394 343 301 266 237 212 190 172 155 141 129 426 378 337 303 274 248 226 207 191 176 163 151 426 377 337 303 273 248 226 207 191 176 163 151 141 568 476 404 346 299 260 228 201 178 159 142 127 457 394 343 301 266 237 212 190 172 155 141 129 426 378 337 303 274 248 226 207 191 176 163 151 426 377 337 303 273 248 226 207 191 176 163 151 141 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The ICD-300 (INVERTED) is the IRD-300 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-300 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-08. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-08. To establish the shear-bond capacity of the ICD300 inverted composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-08. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Imperial) Determine the specified uniformly distributed live load that can be placed on the IDEAL inverted composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.036 in. Yield strength = 33 ksi 3 Normal density concrete = 145 lb/ft Overall slab depth = 6.5 in. Triple span, each = 12 ft Specified superimposed dead load, DL = 32.5 psf Solution: The maximum specified load in (psf) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 12 ft span, the maximum specified load is 129 psf, therefore, 129 ≥ [LL + (1.25/1.5)32.5] and solving for LL, LL = 102 psf Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 4.5”. -At middle support use n=6”. STEEL DECK SECTION PROPERTIES Base Steel Thickness (mm) 0.762 0.914 1.219 1.524 Area of Steel (mm2 ) 1306 1568 2090 2613 COMPOSITE SLAB INFORMATION (per metre of width) Mass Section Modulus Deflection Z275 Midspan Support Inertia (kg/m2 ) (x103mm3 ) (x103 mm3) (x106 mm4 ) 10.5 24.0 23.4 1.15 12.6 30.3 30.0 1.39 16.7 42.9 41.3 1.85 20.8 53.6 52.7 2.32 (per metre of width) Slab Depth, D (mm) 130 140 150 160 Slab weight (kPa) 2.44 2.67 2.89 3.12 3.35 Concrete Volume (m3/10m2) 0.99 1.09 1.19 1.39 170 1.29 MAXIMUM SPECIFIED UNIFORMLY DISTRIBUTED LOADS (kPa) Slab Depth, D (mm) Base Steel Slab Thickness Span (mm) (m) 2.2 2.4 2.5 2.6 2.8 3.0 0.762 3.2 3.4 3.5 3.6 3.8 4.0 2.2 2.4 2.5 2.6 2.8 3.0 0.914 3.2 3.4 3.5 3.6 3.8 4.0 2.5 2.6 2.8 3.0 3.2 3.4 1.219 3.5 3.6 3.8 4.0 4.2 4.4 2.6 2.8 3.0 3.2 3.4 3.5 3.6 1.524 3.8 4.0 4.2 4.4 4.5 4.6 130 140 Deck Span 150 Deck Span 160 170 Deck Span Deck Span Deck Span 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 12.1 9.9 9.0 8.3 7.0 5.9 5.1 4.4 4.1 3.8 3.3 2.9 13.7 11.3 10.4 9.5 8.1 7.0 6.1 5.3 5.0 4.7 4.1 3.7 12.9 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 4.0 3.9 12.1 9.9 9.0 8.3 7.0 5.9 5.1 4.4 4.1 3.8 3.3 2.9 13.7 11.3 10.4 9.5 8.1 7.0 6.1 5.3 5.0 4.7 4.1 3.7 12.9 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 4.0 3.9 12.1 9.9 9.0 8.3 7.0 5.9 5.1 4.4 4.1 3.8 3.3 2.9 13.7 11.3 10.4 9.5 8.1 7.0 6.1 5.3 5.0 4.7 4.1 3.7 12.9 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 12.0 10.3 9.0 7.9 7.0 6.6 6.3 5.6 5.1 4.6 4.2 4.0 3.9 13.3 10.9 10.0 9.1 7.7 6.5 5.6 4.8 4.5 4.2 3.7 3.2 15.1 12.5 11.5 10.5 9.0 7.7 6.7 5.9 5.5 5.2 4.6 4.1 14.3 13.2 11.4 10.0 8.8 7.8 7.3 6.9 6.2 5.6 5.1 4.7 13.2 11.4 9.9 8.7 7.8 7.3 6.9 6.2 5.6 5.1 4.7 4.5 4.3 13.3 10.9 10.0 9.1 7.7 6.5 5.6 4.8 4.5 4.2 3.7 3.2 15.1 12.5 11.5 10.5 9.0 7.7 6.7 5.9 5.5 5.2 4.6 4.1 14.3 13.2 11.4 10.0 8.8 7.8 7.3 6.9 6.2 5.6 5.1 4.7 13.2 11.4 9.9 8.7 7.8 7.3 6.9 6.2 5.6 5.1 4.7 4.5 4.3 13.3 10.9 10.0 9.1 7.7 6.5 5.6 4.8 4.5 4.2 3.7 3.2 15.1 12.5 11.5 10.5 9.0 7.7 6.7 5.9 5.5 5.2 4.6 4.1 14.3 13.2 11.4 10.0 8.8 7.8 7.3 6.9 6.2 5.6 5.1 4.7 13.2 11.4 9.9 8.7 7.8 7.3 6.9 6.2 5.6 5.1 4.7 4.5 4.3 14.6 12.0 10.9 10.0 8.4 7.2 6.1 5.3 4.9 4.6 4.0 3.5 16.5 13.7 12.5 11.5 9.8 8.4 7.3 6.4 6.0 5.6 5.0 4.4 15.6 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 4.9 4.7 14.6 12.0 10.9 10.0 8.4 7.2 6.1 5.3 4.9 4.6 4.0 3.5 16.5 13.7 12.5 11.5 9.8 8.4 7.3 6.4 6.0 5.6 5.0 4.4 15.6 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 4.9 4.7 14.6 12.0 10.9 10.0 8.4 7.2 6.1 5.3 4.9 4.6 4.0 3.5 16.5 13.7 12.5 11.5 9.8 8.4 7.3 6.4 6.0 5.6 5.0 4.4 15.6 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 14.5 12.5 10.9 9.6 8.5 8.0 7.6 6.8 6.2 5.6 5.1 4.9 4.7 15.8 13.0 11.9 10.8 9.1 7.8 6.7 5.8 5.4 5.0 4.4 3.8 17.9 14.9 13.6 12.5 10.7 9.2 8.0 7.0 6.5 6.1 5.4 4.8 17.0 15.7 13.6 11.8 10.4 9.2 8.7 8.3 7.4 6.7 6.1 5.5 15.7 13.6 11.8 10.4 9.2 8.7 8.2 7.4 6.7 6.1 5.5 5.3 5.1 15.8 13.0 11.9 10.8 9.1 7.8 6.7 5.8 5.4 5.0 4.4 3.8 17.9 14.9 13.6 12.5 10.7 9.2 8.0 7.0 6.5 6.1 5.4 4.8 17.0 15.7 13.6 11.8 10.4 9.2 8.7 8.3 7.4 6.7 6.1 5.5 15.7 13.6 11.8 10.4 9.2 8.7 8.2 7.4 6.7 6.1 5.5 5.3 5.1 15.8 13.0 11.9 10.8 9.1 7.8 6.7 5.8 5.4 5.0 4.4 3.8 17.9 14.9 13.6 12.5 10.7 9.2 8.0 7.0 6.5 6.1 5.4 4.8 17.0 15.7 13.6 11.8 10.4 9.2 8.7 8.3 7.4 6.7 6.1 5.5 15.7 13.6 11.8 10.4 9.2 8.7 8.2 7.4 6.7 6.1 5.5 5.3 5.1 17.1 14.0 12.8 11.7 9.9 8.4 7.2 6.2 5.8 5.4 4.7 4.2 19.3 16.1 14.7 13.5 11.5 9.9 8.6 7.5 7.0 6.6 5.9 5.2 18.4 17.0 14.7 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 17.0 14.6 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 5.7 5.5 17.1 14.0 12.8 11.7 9.9 8.4 7.2 6.2 5.8 5.4 4.7 4.2 19.3 16.1 14.7 13.5 11.5 9.9 8.6 7.5 7.0 6.6 5.9 5.2 18.4 17.0 14.7 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 17.0 14.6 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 5.7 5.5 17.1 14.0 12.8 11.7 9.9 8.4 7.2 6.2 5.8 5.4 4.7 4.2 19.3 16.1 14.7 13.5 11.5 9.9 8.6 7.5 7.0 6.6 5.9 5.2 18.4 17.0 14.7 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 17.0 14.6 12.8 11.2 10.0 9.4 8.9 8.0 7.2 6.6 6.0 5.7 5.5 Note: Shoring required at midspan in shaded areas. TECHNICAL NOTES Material Properties 1. The ICD-300 (INVERTED) is the IRD-300 roof deck with embossments rolled into the web elements to achieve the composite interlocking capacity between the steel deck and concrete. 2. Steel deck section properties were calculated in accordance with CSA S136-07. 3. Steel conforms to ASTM A653 SS Grade 33 and A653M SS Grade 230 with Z275 (G90) and ZF75 (A25) surface coatings. 4. Concrete is based on normal density of 2300 3 kg/m (145 pcf) and having a minimum compressive strength of 20 MPa (3 ksi). Load Tables 1. Loads are maximum specified uniformly 2. 3. 4. 5. 6. distributed loads resulting from human occupancy and should not be used for concentrated loads. Maximum specified load from load table must be ≥ [LL + 0.833DL]; Where LL = specified live load; DL = specified dead load; 0.833 = 1.25/1.5 Loads greater than 10 kPa (200 psf) are commonly the result of large concentrated moving loads. In such cases, appropriate design consideration should be used by the structural engineers. The ICD-300 steel deck provides the positive reinforcement for the simply supported composite slab and no additional reinforcing steel is required. To control shrinkage and temperature cracking, a minimum steel wire mesh of 152 x 152 – MW9.1/MW9.1 (6 x 6 - 10/10) is recommended as per CSSBI S3-08. Shoring requirements shown in shaded areas of the load table were established in accordance with CSSBI 12M-08. To establish the shear-bond capacity of the ICD300 inverted composite slab system, laboratory tests were carried out at the Structural Testing and Research laboratory (STAR), Cambridge, Ontario in accordance with CSSBI S2-08. All technical information and load tables were prepared by Dr. R.M. Schuster, Professor Emeritus of Structural Engineering, University of Waterloo, Ontario. EXAMPLE (Metric) Determine the specified uniformly distributed live load that can be placed on the IDEAL inverted composite floor slab, given the following information: Given: • • • • • • Steel deck thickness = 0.914 mm Yield strength = 230 MPa 3 Normal density concrete = 2300 kg/m Overall slab depth = 160 mm Triple span, each = 3.5 m Specified superimposed dead load, DL = 1.60 kPa Solution: The maximum specified load in (kPa) from load table must be ≥ [LL + (1.25/1.5)DL], where LL = specified live load DL = specified superimposed dead load From load table under 3.5 m span, the maximum specified load is 6.5 kPa, therefore, 6.5 ≥ [LL + (1.25/1.5)1.6] and solving for LL, LL = 4.77 kPa Since this is in the shaded area, one shore support is required at mid-span in each span. Note: -The self-weight of the steel deck and concrete slab have already been accounted for in the maximum specified uniformly distributed load given in the composite slab load table. -Minimum Bearing Length “n” at end support is 1.5 x height of deck = 114mm. -At middle support use n=150mm. Acoustic roof deck is designed to serve as a sound-absorbing ceiling or an interior wall cladding (e.g. school gymnasium, training facilities, airports and others) while maintaining most of its structural properties. Using the IRD-150 and IRD-151 load table, the designer is urged to reduce the vertical load resistance by 5%. The webs of the roof deck are perforated with 1/8” (3mm) diameter holes staggered 3/8” (9.53mm) on center. The sound reduction is achieved by fibreglass strips placed between the perforated webs. These strips can be supplied by Ideal Roofing and are available as a special order. IRD-150 and IRD-151 Acoustic Deck is available in 22 gauge (0.030”/0.762mm), 20 gauge (0.036”/0.914mm) and 18 gauge (0.048”/1.219mm) in galvanized G90 (Z275), galvanized G60 (Z180), galvanneal (satin coat) A25 (ZF075) and pre-painted. Acoustic roof deck is designed to serve as a sound-absorbing ceiling or an interior wall cladding (e.g. school gymnasium, training facilities, airports and others) while maintaining most of its structural properties. Using the IRD-300 and IRD-301 load table, the designer is urged to reduce the vertical load resistance by 10%. The webs of the roof deck are perforated with 1/8” (3mm) diameter holes staggered 3/8” (9.53mm) on center. The sound reduction is achieved by fibreglass strips placed between the perforated webs. These strips can be supplied by Ideal Roofing and are available as a special order. IRD-300 and IRD-301 Acoustic Deck is available in 22 gauge (0.030”/0.762mm), 20 gauge (0.036”/0.914mm) and 18 gauge (0.048”/1.219mm) in galvanized G90 (Z275), galvanized G60 (Z180), galvanneal (satin coat) A25 (ZF075) and pre-painted.