Connecting systems
Transcription
Connecting systems
1/2015 Connecting systems for modern timber construction engineering Certainly a great connection. 2 Certainly a great connection. Welcome to the World of KNAPP®! As a producer of patented connecting systems we develop and produce high-quality products which are distributed worldwide. Not only will our connecting systems convince – but also inspire you with the wide range of applications. The comprehensive service offers you the possibility to find the best, the most efficient and innovative solution for the realisation of your products. On the following pages you will find our connector systems for modern timber engineering. IFriedrich Knapp Company founder Our Service The KNAPP®-Team provides competent advice and excellent service for your projects. I In Germany and Austria we offer full-coverage service by representatives on-site. You will find the right contact person easily and quickly. www.knapp-connectors.com/ad I You can reach our internal consultants in Germany and Austria, Monday – Tuesday 8 a.m. to 5 p.m. and on Friday 8 a.m. to 13 p.m. I You can reach our global sales manager on phone +43 (0)664 / 88 51 52 87 or E-Mail : [email protected] www.knapp-connectors.com/contact Our Planner Service Planner service I You can visit our online-shop 24 hours a day. Here you will receive comprehensive information about products and service. After one-time registration you will be able to use the download area. www.knapp-connectors.com/download I We offer comprehensive planning and structural-engineering calculations for architects, planners and structural engineers. Contact us for your next project! We‘d like to offer you statics pre dimensioning, recommending the right connector from KNAPP®. Benefit from our know-how, many years of experience and rely on our engineers consulting. www.knapp-connectors.com/planner 24h bestellen KNAPP® online-store | Order around the clock You want to be flexible and order at any time? No problem! In our online-store you can easily find the most fitting connecting system for any purpose and send your order by one mouse click. After a quick registration, you can immediately start buying online. www.knapp-connectors.com/online-store KNAPP® offers the right connection for the areas of: I Timber construction I Post-beam wood-glass-facade I Prefab walls I Timber construction engineering I Door- and window construction I Furniture and interior design I Glued glass elements for timber and metal construction ms tingstrusyctioste n Connernec con timber for mod a great Certainly More information www.knapp-connectors.com/folder s system tingwoo facades d-glassConnernec am post-be for mod n. connectio a great Certainly for mod a great Certainly ETA ETA imber ETA acade rs.com/t onnecto knapp-c ms tings syste Connernec wall prefab n. connectio rs.com/f onnecto knapp-c ms ring tingstrusyctioste n enginee Connernec con timber for mod n. connectio a great Certainly lls for mod a great Certainly egant refabwa rs.com/p onnecto knapp-c stemctios n ting sy constru Connernec window door and n. connectio for mod a great Certainly fbau rs.com/m onnecto knapp-c stemgns ting sy rior desi Connernec and inte furniture n. connectio Glued glass a great Certainly urniture rs.com/t onnecto knapp-c m ion e Syste al construct –Facad d- and met ern woo FASCO® for mod elements n. connectio rs.com/f onnecto knapp-c co.at www.fas n. connectio Concealed | Self-tightening | Demountable MEGANT® | The heavy-duty connector for timber construction engineering up to 500 kN System advantages: ILoad range - standard sizes up to 341 kN, customized solutions up to 500 kN IMinimum timber width ≤ 100 mm IConnection options – on wood, steel or concrete IUnique – mounting possible from all directions without tilting ILoadable in all directions IFire protection – three sided concealed jointless installation IShort crane times by a high degree of prefabrication – only 2 cm hooking way IDismountable - installed to connect and rebuild Installation example with MEGANT®: No reduction of the main beam. Threaded rod with washers and hex nuts. No tilting when mounting! Profiled base plates made of aluminium with fastening holes at 45° and 90°. Conical clamping aluminium caps for closed joints in the connection area. Additional mounting holes for easy installation and high horizontal loads. MEGANT® 290x60x40 MEGANT® 405x60x40 MEGANT® 520x60x40 MEGANT® 290x100x40 More information: www.knapp-connectors.com/megant MEGANT® 405x100x40 MEGANT® 520x100x40 MEGANT® 280x150x50 MEGANT® 430x150x50 MEGANT® 550x150x50 3 4 Certainly a great connection. MEGANT® Application examples and connection details Loading direction 50-500 kN A special purlin design required the installation from below with the possibility of tightening from above. Concealed mounting on three sides by milling the secondary beam and visible mounting on main beam. Insertion direction eam in b Ma x260 0 160 F45,d Connection finished: The secondary beams are placed in the clamping jaws. F45,d F3,d eam dary b Secon 40 2 1200x F1,d eam dary b Secon 0 4 4 80 x 2 F1,d F2,d MEGANT® 420x200x40 With only 2 cm hooking way, a mounting in cutouts of concrete walls can be done. MEGANT® 980x200x60 Secondary beam 840x140 Secondary beam 840x140 Connection on both sides MEGANT® oblique connection. Main beam 840x160 Oblique connection steel concrete F2,d Secondary beam 160/480 MEGANT® 290x100 160 95 30 480 290 95 30 480 290 95 290 30 560 41 F2,d F2,d 41 160 41 Secondary beam 160/480 MEGANT® 290x100 Steel column HEB 160 Secondary beam 160/480 MEGANT® 290x100 Concrete wall Main beam 160x560 160 HT-NT connection (wood-wood connection) secondary beam 160 Steel wood connector 480 MEGANT® on wood Wood concrete connection 5 Concealed | Self-tightening | Demountable MEGANT® screws CS-screws with cut point (MEGANT® is supplied with the appropriate CS-screws) Art.-No. Z1 CS-screw 8x160 with patented half-peak Application: For the positioning and slanted screwing as well as mounting of the clamping jaw of MEGANT ®. MEGANT® Overview, static values MEGANT® 60 - Static values with screws 8x160 in timber quality GL24h Connector Min. secondary beam height [mm] 290x60x40 405x60x40 520x60x40 104x440 104x520 104x640 Characteristic values [kN] max F1,Rk max F2,Rk max F3,Rk 12,8 10,4 7,5 81 24,6 116 35,4 129 45,9 max F45,Rk 45,5 MEGANT® 100 - Static values with screws 8x160 in timber quality GL24h Connector Min. secondary beam height [mm] 290x100x40 405x100x40 520x100x40 142x440 142x520 142x640 Characteristic values [kN] max F1,Rk max F2,Rk max F3,Rk 23,9 23,9 23,9 116 35,4 167 51,0 211 66,1 max F45,Rk 65,6 MEGANT® 150 - Static values with screws 8x160 in timber quality GL24h Connector Min. secondary beam height [mm] 280x150x50 430x150x50 550x150x50 194x360 194x520 194x640 Characteristic values [kN] max F1,Rk max F2,Rk max F3,Rk max F45,Rk 33,8 33,8 33,8 109 35,4 65,6 204 66,1 265 85,7 82,7 Custom solutions of MEGANT® Special sizes on request (Examples on the list) 720x150x50 830x150x50 1060x150x50 1120x150x50 194x780 194x895 194x1125 194x1180 33,8 33,8 12,3 7,0 352 409 85,7 521 82,7 548 Certificates for F1 and F2 must be splitted and not to be combined ! A testable structural predimensioning is available upon request from KNAPP®. Factor f for other timber species GL24c GL24h GL28h GL32h 0,94 1,00 1,06 1,10 F1,d F45,d eam Characteristic values for traction Characteristic values in direction of insertion Characteristic values against the direction of insertion Characteristic values perpendicular to the direction of insertion in b Ma F1,Rk F2,Rk F3,Rk F45,Rk F3,d F45,d dary Secon m a e b dary Secon beam F2,d F1,d 6 Certainly a great connection. MEGANT® Assembly procedure 13:16 | After aligning the secondary beam, MEGANT® is hooked. 13:21 | For threading and dropping, MEGANT® requires only 2 cm. 13:23 | Insert the threaded rods and drill them into the caps. 13:24 | Tighten the nuts. 13:25 | Connection finished. MEGANT® Fire protection IIs an invisible connection required or particular requirements for fire protection, the system can be easily processed on 3 sides covered. IJointless connection - no additional covers or fire protection ribbons required. IAccording to DIN4102-2 20 mm wood covering are required for 30 minutes fire resistance. Even a higher fire resistance (i.e. R60) is possible. MEGANT® Drilling-jig MEGANT® Art.-Nr. K08030663/00001 Art.-Nr. K08030664/00001 Art.-Nr. K08030665/00001 Art.-Nr. K08030666/00001 Art.-Nr. K08030667/00001 Drilling-jig MEGANT® 290x60x40 Drilling-jig MEGANT® 405x60x40 Drilling-jig MEGANT® 520x60x40 Drilling-jig MEGANT® 290x100x40 Drilling-jig MEGANT® 405x100x40 Art.-Nr. K08030668/00001 Art.-Nr. K08030669/00001 Art.-Nr. K08030670/00001 Art.-Nr. K08030671/00001 Application: For an exact predrilling of the positioning screwing. Drilling-jig MEGANT® 520x100x40 Drilling-jig MEGANT® 280x150x50 Drilling-jig MEGANT® 430x150x50 Drilling-jig MEGANT® 550x150x50 MEGANT® Custom solutions for forces up to 500 kN IComprehensive advice from your personal contact and our technical department IProfessional support for project-related detailed preparation and static predimensioning ICreate an optional project-based verifiable static MEGANT® for 420 kN Example: Storage hall Großarl (A) Oblique connections Example: Restaurant Schnepfenried (FR) Static calculation by external engineering office. Concealed | Self-tightening | Demountable 7 RICON® S | The connector for main and secondary beam up to 100 kN* System advantages: IConnector for timber frame, wood frame buildings and halls ITimber width from 100 mm upwards IUniversally applicable to timber, steel or concrete ISimple screwing without predrilling IEasy hooking by large V-shaping – only 3,5 cm hooking way IThree- and four-sided concealed connection IHigh fire resistence through three- and four-sided concealed mounting IAdjustable collar bolt up to 5mm length tolerance at full load capacity IOptional – securing against the insertion direction with clip lock INEW: ETA additionally with hardwood material The V-shape moulding provides perfect catch of the collar bolt. The strong tension and the short slide-in alleviates the connecting and guarantees joint sealing. RICON® S is made of premium quality steel, hot-dip galvanized and produced in Germany. KNAPP® CS-screws with cut point for extra fast starts and screwing. The reinforced shaft provides force-fit connection. RICON® S60 VS 140x60x25 RICON® S60 VS 200x60x25 The RICON®S clip lock, made from stainless spring steel, locks the connection against slide-in direction and can optionally be used for stress against slide-in direction or wind suction. There are different versions of the collar bolt available for RICON® S which offers four different connection options. ETA More information: www.knapp-connectors.com/ricons RICON® S80 VS 200x80x25 *Charact. load carrying capacity F2,Rk in insertion direction applies only to the use of original KNAPP® cs-screws according to ETA 10/0189. RICON® S80 VS 290x80x25 8 Certainly a great connection. RICON® S Application examples and connection details Ridged roof with purlins and latch connections F2 Single connection aN,i Joining header/joint with RICON® S Single and double connection HN Full-thread screws with cut point for lateral compression reinforcements of header Longitude L F2 t1 Header Joint Joint Header BH in rl Pu Pillar F2 Double connection Rid ge F2 Joint f ra Joint Header dr oo fte r ch Lat t2 RICON® S60: Fit bolt/thread bar Ø 8 mm with jam nut M8 RICON® S80: Fit bolt/thread bar Ø 10 mm with jam nut M10 F Pillar 5 e Header and joint with retaining screw Latch 26 Ø ≥ 50 Pillar/Post RICON® S housed into a rafter Rafter 100/400 Rafter 100/400 1640 22° I Hall roof of carpentry S. Hinrichsen (Germany) 22° 400 Connection RICON® S VK 400 RICON® S VK Ridge purlin 240/1640 240 RICON® S housed into the ridge beam 400 Ridge beam 240/1640 400 RICON® S VK Rafter 100/400 (All dimensions in mm) Ridge Purlin 1640 Rafter 100/400 9 Concealed | Self-tightening | Demountable RICON® S Application prefabricated houses Connecting header with timber frame construction or cross-laminated timber wall Steel connection 4,50 F2 4,50 F1 E1 HN Zusatzbefestigung der ZWISCHENSCHICHT F1 interior wall. E1.1 Bearer 160/240 E1 Joist 120/240, e=100 cm E3 Joint/ Header Header 140/240 4,50 F Cross-laminated timber wall F2 Non-load bearing E2 Beam 200/360 Interlayer tzw < 26 Joist 120/240, e=100 cm 4,50 Joint Header I First node for dome Main floor Main floor footprint footprint Top floor footprint RICON S mit verschraubten Kragenbolzen HAUPTTRÄGER F2 B F2 F1 RICON® S 200x80 connection of a joist F2 Ceiling of a timber frame construction F1 F2 Joist 120/240 F1 F1 Stanchion IPE 240, ST 37 Hauptträgerzangenanschluß mit Schwer er ad 60 He 0/3 2 1 320 Vierseitiger Stützenanschluss mit Schwerlastverbinder F2 F2 F1 2 RICON® S with 11 PB 10x160 each Post 140/14 0 F4 F2 F1 F2 F2 Beam 140/ connectio 240, e = 1,00 m n to post w RICON® S 20 ith 0x80 F1 220 ith tw 60 s /3 o po 0 0 t 8 14 n x er tio 90 ad nec ® S 2 e H on N c ICO R F2 F4 F1 F5 F5 Alternative ways to connect 10 Certainly a great connection. RICON® S Characteristic values for dimensioning can be taken from the ETA Static Folder. RICON® S / - Collar bolts and screwing Art.-No. VS: K / VK: K / EK: K / GK: K HeaderJoint 12 12 Screwing Connector Joint Header 140/60 VS 10 x CS 8x160 10 x CS 8x80 53,0 140/60 VK D12 8 x CS 8x160 8 x CS 8x80 39,8 A Available on request: 40 KNAPP Z-9.1-698 10 30 Minimum screwing : n = 7 60 Ø od 12 Ø 2 er 2 140 40 Ø 8 Ø 6 Holzforschung Austria A 8 60 A-A 5 Charact. values [GL24h] F2,Rk [kN] Collar bolt 140/60 EK M12 7 x CS 8x160 7 x CS 8x80 36,0 140/60 GK M12 7 x CS 8x160 7 x CS 8x80 36,0 Clip lock: F3,Rk = 18,0 kN Minimum timber cross section: 100 x 160 mm RICON® S 200/60 - Collar bolts and screwing Art.-No. VS: K7 / VK: K / EK: K / GK: K36 12 HeaderJoint 12 40 A 10 30 Ø od 12 Ø 2 er 2 Minimum screwing : n = 8 Joint Header 200/60 VS 16 x CS 8x160 16 x CS 8x80 60,0 200/60 VK D12 9 x CS 8x160 9 x CS 8x80 49,7 200/60 EK M12 8 x CS 8x160 8 x CS 8x80 44,7 200/60 GK M12 8 x CS 8x160 8 x CS 8x80 44,7 40 KNAPP Z-9.1-698 Holzforschung Austria Clip lock: F3,Rk = 18,0 kN A 8 22 60 5 RICON® S A-A Minimum timber cross section: 100 x 220 mm Characteristic values for dimensioning can be taken from the ETA Static Folder. RICON® S 200/80 - Collar bolts and screwing Art.-No. VS: K8 / VK: K8 / EK: K53 / GK: K142 16 Joint 12 A Screwing Connector Collar bolt 200/80 VS 200/80 VK D16 Joint Header 40 Header Ø od 16 Ø 2 er 2 Holzforschung Austria A 10 30 Minimum screwing : n = 8 80 A-A 5 16 A 100 9 x CS 10x200 9 x CS 10x100 70,5 EK M16 8 x CS 10x200 8 x CS 10x100 63,0 200/80 GK M16 8 x CS 10x200 8 x CS 10x100 63,0 Clip lock: F3,Rk = 18,0 kN Minimum timber cross section: 120 x 230 mm Connector 12 16 x CS 10x200 16 x CS 10x100 200/80 RICON® S 290/80 - Collar bolts and screwing Art.-No. VS: K9 / VK: K41 / EK: K56 / GK: K145 Joint Charact. values [GL24h] F2,Rk [kN] Available on request: 40 10 30 KNAPP Z-9.1-698 200 120 Ø 10 Ø 6 Header Charact. values [GL24h] F2,Rk [kN] Available on request: 200 120 Ø 8 Ø 6 Screwing Collar bolt Connector Screwing Collar bolt Joint 290/80 VS 290/80 VK D16 Header Charact. values [GL24h] F2,Rk [kN] 20 x CS 10x200 20 x CS 10x100 100 9 x CS 10x200 70,5 9 x CS 10x100 Ø 10 Ø 6 290 210 Available on request: EK M16 8 x CS 10x200 8 x CS 10x100 63,0 GK M16 8 x CS 10x200 8 x CS 10x100 63,0 Clip lock: F3,Rk = 18,0 kN Ø od 16 Ø 2 er 2 Minimum timber cross section: 120 x 320 mm KNAPP 10 30 Minimum screwing : n = 8 290/80 290/80 40 Z-9.1-698 Holzforschung Austria A 10 30 80 5 A-A 11 Concealed | Self-tightening | Demountable RICON® S Pre-dimension Minimum timber cross section for joint for RICON® S connection in reference to uniformly distributed load qk and span L for glued laminated timber and GL h according DIN (release 2008) and Eurocode Roofs, rafters, rafter latches (service classes -, load-duration class: short-term) Dead-load gk (40%) e. g. self-weight and alternating load qk (60%) e. g. wind, snow, live-load Uniformly distributed load qk Span L 4,00 m 5,00 m 6,00 m 7,00 m 8,00 m qk = 3,00 kN/m qk = 4,00 kN/m qk = 5,00 kN/m qk = 6,00 kN/m qk = 7,00 kN/m qk = 8,00 kN/m Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] RICON® S 10/20 140/60 10/26 200/60 12/28 200/60 12/34 200/80 12/38 290/80 RICON® S 10/22 140/60 12/26 200/60 12/32 200/80 12/36 290/80 12/42 290/80 RICON® S 10/24 200/60 12/28 200/60 12/34 200/80 12/40 290/80 12/46 290/80 RICON® S 10/26 200/80 12/30 200/80 12/36 200/80 12/42 290/80 12/48 290/80 RICON® S 12/26 200/80 12/32 200/80 12/38 290/80 12/44 290/80 RICON® S 12/28 200/80 12/34 200/80 12/40 290/80 Residential building, ceilings (service classes -, load-duration class: medium-term) Dead-load gk (40%) e. g. self-weight and alternating load qk (60%) e. g. wind, snow, live-load Uniformly distributed load qk Span L 4,00 m 5,00 m 6,00 m 7,00 m 8,00 m qk = 3,00 kN/m qk = 4,00 kN/m qk = 5,00 kN/m qk = 6,00 kN/m qk = 7,00 kN/m qk = 8,00 kN/m Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] RICON® S RICON® S RICON® S RICON® S RICON® S RICON® S 10/20 140/60 10/26 200/60 12/28 200/60 12/34 200/80 12/38 290/80 10/22 140/60 12/26 200/60 12/32 200/80 12/36 290/80 12/42 290/80 10/26 200/60 12/28 200/60 12/34 200/80 12/40 R290/80 12/46 290/80 12/26 200/80 12/32 200/80 12/38 200/80 12/44 290/80 12/50 290/80 12/28 200/80 12/34 200/80 12/40 290/80 12/28 200/80 12/36 200/80 12/42 290/80 Storage building, ceilings (service classes -, load-duration class: long-term) Dead-load gk (40%) e. g. self-weight and alternating load qk (60%) e. g. wind, snow, live-load Uniformly distributed load qk Span L 4,00 m 5,00 m 6,00 m 7,00 m 8,00 m qk = 3,00 kN/m qk = 4,00 kN/m qk = 5,00 kN/m qk = 6,00 kN/m qk = 7,00 kN/m qk = 8,00 kN/m Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] Cross timber section w/l [cm/cm] RICON® S RICON® S RICON® S 10/24 140/60 12/28 200/60 12/32 200/80 12/38 290/80 12/44 290/80 10/26 200/60 12/30 200/60 12/36 200/80 12/42 290/80 12/48 290/80 RICON® S 12/26 200/80 12/34 200/80 12/40 290/80 12/46 290/80 RICON® S 12/28 200/80 12/36 290/80 12/42 290/80 RICON® S 10/22 140/60 10/26 200/60 12/28 200/60 12/34 200/80 12/38 290/80 12/30 200/80 12/38 290/80 Connec tion Character istic Systems and desig I ETA STATIC n values S FOLDE R / Stati c examples Concealed | The table values are only to be applied for loading in direction of insertion. The minimum cross section of the secondary beam is calculated for timber C24 (S10). For the connection force of GIGANT, the live load over the bearing was set to 1,0 kN (man load upon the bearing). Detailed information for static calculation are indicated in the ETA Static Folder. Find more information at www.knapp-verbinder.com/download * Technical contents are valid, until an update is available (online on website). ETA I For all soft- and hardwo ods Self-tight valid from 2014-11-01* ening | Demount able 12 Certainly a great connection. RICON® S screws CS-screws RICON® S60 with cut point (RICON® S will supplied with the appropriate CS-screws) Art.-No. Z0 Art.-No. Z1 CS-screw 8x80 with patented half-peak CS-screw 8x160 with patented half-peak Application: To screw in longitude (8x80) or end grain (8x160). CS-screws RICON® S80 with cut point (RICON® S will supplied with the appropriate CS-screws) Art.-No. Z Art.-No. Z3 CS-screw 10x100 with patented half-peak CS-screw 10x200 with patented half-peak Application: For screwing RICON® S into main (post) or secondary beam (latch). RICON® S Accessories Routing-jig RICON® S S/S Art.-No. K10 Art.-No. K11 Routing-jig MULTI F6 (plywood) for all RICON® S60 sizes Routing-jig MULTI F (plywood) for all RICON® S60 sizes Advice: The routing-jig MULTI F is suitable for a Ø = 30 mm guide bush (for plunge router) and a Ø = 15 mm TCT router cutter. Application: For milling in concealed mounting. TCT router cutter Art.-No. Z068 TCT router cutter Ø = 15, Length =40 mm and Ø = 12 mm Schaft Application: To recess the rebate for RICON® S. Pan head screws RICON® S80 Art.-No. Z521 Art.-No. Z522 PH-screw 10x80 PH-screw 10x120 Application: For screwing the interlayer on slanted screw connections. Full threaded CS-screws with cut-point Header F Full-thread screws with cut point for lateral compression reinforcements of header Joint BH Application: Diameter (d1) Length (mm) Ø = 8 mm 160 180 200 220 240 260 280 300 350 400 450 500 550 600 Ø = 10 mm 160 180 200 220 240 260 280 300 350 400 450 500 550 600 Sizes available on request. Full threaded countersunk screws for lateral compression reinforcements of header and/or joint. Clip lock RICON® S (made of stainless spring steel) Clip lock RICON® S60 Clip lock RICON® S80 15,7 16 Art.-No. K Art.-No. K 50 Application: 60 8 Ø Ø 10 44 80 60 51 The clip lock locks the connection against slide-in direction and is used for stress against slide-in direction or wind suction. 2. :06S ®NOCIR 08x8 :TH 061x8 :TN 13 .2 Concealed | Self-tightening | Demountable RICON® S collar bolt Screwed collar bolt (VK) Art.-No. Z Art.-No. Z S80: VK D16 S60: VK D12 :08S ®NOCIR 001x01 :TH 002x01 :TN 1. Position collar bolt into the provided hole 2. Fasten collar bolt with full threaded CS-screw 1. F Necessary screws : RICON® S60: 2. 1. Joint Header 1. Kragenbolzen in vorgesehenes HT: 8x80 Loch einsetzen NT: 8x160mit Vollgewinde2. Kragenbolzen Schraube befestigen RICON® S80: HT: 10x100 Verwendete Schraube: RICON® NT: S60: 10x200 HT: 8x80 NT: 8x160 2. nerhobrov hcolkcaS .1 rettumgnaL tim KS nezlobnegRICON® arK .2 S80: rednibreV ma rettumretnoK dnHT: u 10x100 nebuarhcsreNT: v 10x200 neheiztsef dnu nelletsnie ehöH .3 dnu nekcets hcolkcaS ni rednibreV .4 negitsefeb nebuarhcS S ®NOCIR tim 1. Position collar bolt into the provided hole 2. Fasten collar bolt with full threaded CS-screw Necessary screws : RICON® S60: Application: HT: 8x80 NT: 8x160 Art.-No. Z558 Art.-No. Z559 .1 .2 .2 2. Fasten socket headon screw Screwed collar bolt for fast 3.and direct screwing, especially interlayers. coupling nut and 08S ®NOCIR ieb gnurhowith B Hint: This way of connection requires very accurate rebate depth (no tolerances). jam nut to the connector t mm 82 = D ,mm 05 = t 3. Adjust height and tighten up 4. Plug connectors in blind hole and fasten with RICON® S CS-screws 1. 2. S60: EK M12 S80: EK M16 Zusatzbefestigung der ZWISCHENSCHICHT Depth:vorbohren t = 40 mm, 1. Sackloch 2. Kragenbolzen Diameter:SKDmit = Langmutter 22 mm und Kontermutter am Verbinder verschrauben Blind hole und for festziehen RICON® S80 3. Höhe einstellen 4. Verbinder stecken und Depth:intSackloch = 50 mm, mit RICON® S Schrauben befestigen 3. t 1. 2. HAUPTTRÄGER Screwed collar bolt Bohrung bei RICON® S80 t = 50 mm, D = 28 mm 1. Bore blind hole 2. Fasten socket head screw with coupling nut and jam nut to the connector 3. Adjust height and tighten up 4. Plug connectors in blind hole and fasten with RICON® S CS-screws Application: RICON S mit verschraubten Kragenbolzen Diameter: D = 28 mm Bohrung bei RICON® S60 t = 40 mm, D = 22 mm Blind hole for RICON® S60 Depth: t = 40 mm, Diameter: D = 22 mm F Blind hole for RICON® S60 2. t 1. Interlayer tzw < 26 06S ®NOCIR ieb gnurhoB 1. Bore blind hole mm 22 = D ,mm 04 = t RICON® S80: 2. Retaining HT: 10x100 screw collar bolt (EK) NT: 10x200 .3 t nerhobrov hcolkcaS .1 hcsnalF tim KS nezlobnegarK .2 ma esuähegnezlobredeF dnu negitsefeb rednibreV dnu nekcets hcolkcaS ni rednibreV .3 negitsefeb nebuarhcS S ®NOCIR tim Screwed collar bolt .3 Thread bar t .1 06S ®NOCIR ieb gnurhoB mm 03 = D ,mm 6 = t blind hole 1.0Bore .2 .2 Jam nut Retaining screw collar bolt for connections2.to concrete and/or Fasten socket head screw wood components for timber engineering. 08S ®NOCIR ieb gnuwith rhoB flansh nut and spring bolt Coupling nuts are used to connect pieces rod, anchor bolt or connecting bolts. mm 53 = D ,mof m 0housing 7threaded =t on the connector Blind hole for RICON® S80 Depth: t = 50 mm, SpringD retaining Diameter: = 28 mm 3. screw collar bolt (GK) 2. Art.-No. Z592 S60: GK M122. Art.-No. Z593 S80: GK M16 3. Plug connector in blind hole and fasten with RICON® S CS-screws t 1. 3. 2. 2. t 1. 1. Blind Sackloch vorbohren hole for RICON® S60 2. Depth: Kragenbolzen mit Flansch t = 60SKmm, und Federbolzengehäuse am Diameter: D = 30 mm Verbinder befestigen 3. Verbinder in Sackloch stecken und Blind holeSfor RICON®befestigen S80 mit RICON® Schrauben Depth: t = 70 mm, Diameter: = 35 mm Bohrung beiDRICON® S60 Depth: t = 40 mm, Diameter: D = 22 mm Blind hole for RICON® S80 Depth: t = 50 mm, Header D = 28 mm Diameter: Hard-wood wedge for disassembling Joint t = 60 mm, D = 30 mm Bohrung bei RICON® S80 t = 70 mm, D = 35 mm t 1. 1. Bore blind hole 2. Fasten socket head screw with flansh nut and spring bolt housing on the connector 3. Plug connector in blind hole and fasten with RICON® S CS-screws Hard-wood wedge for disassembling Blind hole for RICON® S60 Application: Spring retaining holding screw for the installation of components in-between two fixed parts (such as header latches or pillars). Depth: t = 60 mm, Diameter: D = 30 mm Blind hole for RICON® S80 Depth: t = 70 mm, Diameter: D = 35 mm RICON® S Fire resistance IIs an invisible connection required or particular requirements for fire protection, the system can be easily processed on three or four-sides covered. IJointless connection – no additional covers or fire protection ribbons required. IAccording to DIN4102-2 20 mm wood covering are required for 30 minutes fire resistance. Even a higher fire resistance (for example R60) is possible. 14 Certainly a great connection. RICON® S Installation I Routing machine with KNAPP® routing-jig. I Installation with CNC joinery machine possible – all data for the standard CNC joinery machine programms are included. Routing dimensions for RICON® S60 / S80 CNC joinery machine Width Length Depth (VK, EK) 60 mm / 80 mm var. 25 mm Depth (GK) End grain Longitudinal 13 mm 13 mm 1)Routing with routing-jig and routing machine. Installation RICON® S VS 2)Position the screws 3)Screw on 4) Screw on counter part 3)Screw on 4) Screw on counter part Installation RICON® S VK 2)Position the screws Construction manuals, .DXF drawings for RICON® S-System as well as your personal consultant in your area, please visit: www.knapp-connectors.com/download Recommended software partners for machine processing: Concealed | Self-tightening | Demountable 15 RICON®, RICON® S, MEGANT® Selected reference project Object: renovation of a restaurant in Schnepfenried/France; SMA Syndicat mixte d‘aménagement des stations de montagne de la vallée de Munster, F-68140 Munster; Architect: Ateliers d-Form, F-68230 Soultzbach Les Bains, www.atelier-d-form.com; Statics: Optime Ingénierie, 68230 Soultzbach Les Bains, contact@ optime-be.com, Construction Companie: Dattler, 20 rue des Prés, 68640 Feldbach, www.dattler.fr Object: Eurospar Attnang-Puchheim; Architect: Dworschak+Mühlbachler Architekten ZT GmbH; Planner: Dworschak+Mühlbachler Architekten ZT GmbH; Statics: Ingenieurbüro Meinhart und Partner Ziviltechniker GmbH; Timber Construction: Schmid Baugruppe Holding AG www.schmid-baugruppe.at Prefab: Buchacher Holzleimbau GmbH; Constructor: GNIGL Projektentwicklung und Errichtungs GmbH Client: Spar Österreichische Warenhandels AG; Modded surface: 2.150 m² Usable Area: 310 m² Service Contact order 24h/24 Download +43 (0)664 / 88 51 52 87 [email protected] +49 (0)8122 / 959 41 0 [email protected] Do you have questions about a optimal solution for your project? Find your sales representative easily on our website: You want to order around the clock? Our KNAPP® online-store is open 24h each day.* All brochures, data sheets, technical details are downloadable from our web site. knapp-connectors.com/contact knapp-connectors.com/ad knapp-connectors.com/online-store knapp-connectors.com/download knapp-connectors.com/contact knapp-connectors.com/ad [email protected] +49 (0)8122 / 959 41 0 [email protected] +43 (0)664 / 88 51 52 87 on our website: Find your sales representative easily solution for your project? Do you have questions about a optimal Contact * not available in Austria and Switzerland. * not available in Austria and Switzerland. knapp-connectors.com/online-store knapp-connectors.com/download each day.* Our KNAPP® online-store is open 24h You want to order around the clock? web site. details are downloadable from our All brochures, data sheets, technical Download Service order 24h/24 1/2015 | KNAPP®-Brochure Timber constr. eng. E 01/2015 © The KNAPP® logo is a registered trademark of the trademarkowner Knapp GmbH, A-3324 Euratsfeld. Concealed | Self-tightening | Demountable The technical contents in this brochure are valid, until a (on our website for download) new brochure is available. This brochure is the exclusive property of Knapp GmbH. Duplication, reproduction or publication, including excerpts, only with the prior written permission of Knapp GmbH. All calculations given in this brochure are made in subject to any printing and typing errors and other mistakes. Technical drawings and calculations, especially those affecting the statics, on customer‘s own responsibility. Any calculations and drawings in this respect by the company Knapp GmbH are subject to proposals for the orientation and / or liability for the accuracy and therefore not free the customer to wear it even for a proper drawing and calculation by a professional concern. Picture credits are available and can be requested if required. All rights reserved. Copyright © 2014 by Knapp GmbH. Knapp GmbH I Wassergasse 31 I A-3324 Euratsfeld I Tel.: +43 (0)7474 / 799 10 I Fax: +43 (0)7474 / 799 10 99 Knapp GmbH Niederlassung Deutschland I Katharina-Fischer-Platz 1 I D-85435 Erding Tel.: +49 (0)8122 / 959 41 0 I Fax: +49 (0)8122 / 959 41 10 I E-Mail: [email protected]
Similar documents
glue laminated timber bsh - Hasslacher Norica Timber
halls, substructures, roof structures that are not exposed, agricultural buildings, etc. Discolourations such as (nail-holding) brown discolouration, blue stain and
More information