series surgical lights - CAN
Transcription
series surgical lights - CAN
SERIES SURGICAL LIGHTS Skytron's Aurora LED Surgical Lighting provides advanced bright, cool and color correct illumination to the surgical field and a selectable color temperature of 4,000K (soft white) or 4,500K (bright white) based upon surgeon preference for every procedure. Focusable LEDs extend illumination range while retaining maximum intensity at any distance, with LED pod life retaining 80% of original intensity for an average of 10 years or 20,000 hours of use. Typical applications include General, Orthopedic, Plastics, Vascular, Cardiovascular, OB/GYN, Trauma, Neurosurgery and Urology. TEC-B-0012 REV1 8/09 AUR5 2267mm 89 1/4" 945mm 37 1/4" 70mm 2 3/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º 360º 110º Wall Control 1765mm 69 1/2" 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 144 watts (490 BTU/hr) • Amperage: 1.6 amps • Intensity: 4,000K=135,000 Lux (12,542fc) 4,500K=120,000 Lux (11,148fc) • Fixture Weight: 132 lbs./59.9 Kg. • Moment Load: 393.2 ft. lbs./532.8 N•m CEILING HEIGHT 8'-4" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-01 REV0 8/09 AUR5TV 2267mm 89 1/4" 945mm 37 1/4" 70mm 2 3/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 1" Diameter Conduit 360º CAMERA READY 360º 110º Wall Control 1765mm 69 1/2" Camera Control Connector 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 144 watts (490 BTU/hr) • Amperage: 1.6 amps • Intensity: 4,000K=135,000 Lux (12,542fc) 4,500K=120,000 Lux (11,148fc) • Fixture Weight: 137.6 lbs./62.4 Kg. • Moment Load: 426 ft. lbs./577.3 N•m CEILING HEIGHT 8'-4" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-02 REV0 8/09 AUR7 2716mm 107" 1140mm 45" 1200mm 47 1/4" 70mm 2 3/4" 360º 3/4" Diameter Conduit 360º 360º 110º Wall Control 1969mm 77 1/2" 2032mm 80" 360º 425mm 16 3/4" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 144 watts (490 BTU/hr) • Amperage: 1.6 amps • Intensity: 4,000K=160,000 Lux (14,870fc) 4,500K=139,000 Lux (12,918fc) • Fixture Weight: 149 lbs./67.6 Kg. • Moment Load: 616.2 ft. lbs./835 N•m CEILING HEIGHT 8'-4" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-03 REV0 8/09 AUR7TV 2716mm 107" 1140mm 45" 1200mm 47 1/4" 70mm 2 3/4" 360º 3/4" Diameter Conduit 1" Diameter Conduit 360º CAMERA READY 360º 110º Wall Control 1969mm 77 1/2" Camera Control Connector 2032mm 80" 360º 425mm 16 3/4" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 144 watts (490 BTU/hr) • Amperage: 1.6 amps • Intensity: 4,000K=160,000 Lux (14,870fc) 4,500K=139,000 Lux (12,918fc) • Fixture Weight: 156.5 lbs./71 Kg. • Moment Load: 655.9 ft. lbs./888.8 N•m CEILING HEIGHT 8'-4" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-04 REV0 8/09 AUR55 2462mm 97" 1140mm 45" 70mm 2 3/4" 945mm 37 1/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º 360º 110º 360º 360º Wall Control 1765mm 69 1/2" 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 288 watts (980 BTU/hr) • Amperage: 3.2 amps • Intensity: 4,000K=270,000 Lux (25,084fc) 4,500K=240,000 Lux (22,296fc) • Fixture Weight: 215.2 lbs./97.6 Kg. • Moment Load: 807.6 ft. lbs./1,094.3 N•m CEILING HEIGHT 8'-9" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-05 REV0 8/09 AUR55TV 2462mm 97" 1140mm 45" 70mm 2 3/4" 945mm 37 1/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º 360º 110º 1" Diameter Conduit 360º CAMERA READY 360º Wall Control 1765mm 69 1/2" Camera Control Connector 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 288 watts (980 BTU/hr) • Amperage: 3.2 amps • Intensity: 4,000K=270,000 Lux (25,084fc) 4,500K=240,000 Lux (22,296fc) • Fixture Weight: 220.7 lbs./100.1 Kg. • Moment Load: 840.5 ft. lbs./1,138.9 N•m CEILING HEIGHT 8'-9" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-06 REV0 8/09 AUR75 2716mm 107" 1200mm 47 1/4" 1140mm 45" 70mm 2 3/4" 945mm 37 1/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º 360º 360º 110º 360º 110º Wall Control 1765mm 69 1/2" 1969mm 77 1/2" 2032mm 80" 360º 360º 425mm 16 3/4" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 288 watts (980 BTU/hr) • Amperage: 3.2 amps • Intensity: 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) • Fixture Weight: 231.5 lbs./105 Kg. • Moment Load: 983.5 ft. lbs./1,332.6 N•m CEILING HEIGHT 8'-9" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-07 REV0 8/09 AUR75TV 2716mm 107" 1200mm 47 1/4" 1140mm 45" 945mm 37 1/4" 70mm 2 3/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º 360º 360º 110º CAMERA READY 360º 110º Wall Control 1765mm 69 1/2" 1969mm 77 1/2" 1" Diameter Conduit Camera Control Connector 2032mm 80" 360º 360º 425mm 16 3/4" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 288 watts (980 BTU/hr) • Amperage: 3.2 amps • Intensity: 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) • Fixture Weight: 239.6 lbs./108.7 Kg. • Moment Load: 1,016.2 ft. lbs./1,377 N•m CEILING HEIGHT 8'-9" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-08 REV0 8/09 AUR7TV5 2716mm 107" 1200mm 47 1/4" 1140mm 45" 70mm 2 3/4" 945mm 37 1/4" 360º 1000mm 39 1/2" 3/4" Diameter Conduit 360º CAMERA READY 360º 360º 110º 360º 110º Wall Control 1765mm 69 1/2" 1969mm 77 1/2" 1" Diameter Conduit Camera Control Connector 2032mm 80" 360º 360º 425mm 16 3/4" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 288 watts (980 BTU/hr) • Amperage: 3.2 amps • Intensity: 4,000K=295,000 Lux (27,412fc) 4,500K=259,000 Lux (24,066fc) • Fixture Weight: 239.6 lbs./108.7 Kg. • Moment Load: 1,023.2 ft. lbs./1,386.5 N•m CEILING HEIGHT 8'-9" min. 10'-5" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-09 REV0 8/09 AUR555 2657mm 105" 1335mm 52 1/2" 945mm 37 1/4" 1140mm 45" 70mm 2 3/4" 3/4" Diameter Conduit 1000mm 39 1/2" 360º 360º 360º 360º 110º 360º 360º 1765mm 69 1/2" Wall Control 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 432 watts (1,469 BTU/hr) • Amperage: 4.8 amps • Intensity: 4,000K=405,000 Lux (37,626fc) 4,500K=360,000 Lux (33,444fc) • Fixture Weight: 312.4 lbs./141.7 Kg. • Moment Load: 1,269.5 ft. lbs./1,720.2 N•m CEILING HEIGHT 9'-2" min. 10'-4" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-10 REV0 8/09 AUR555TV 2657mm 105" 1335mm 52 1/2" 945mm 37 1/4" 1140mm 45" 1" Diameter Conduit 70mm 2 3/4" 3/4" Diameter Conduit 1000mm 39 1/2" 360º 360º 360º 360º 360º 110º CAMERA READY 360º 1765mm 69 1/2" Wall Control Camera Control Connector 2032mm 80" 360º 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 432 watts (1,469 BTU/hr) • Amperage: 4.8 amps • Intensity: 4,000K=405,000 Lux (37,626fc) 4,500K=360,000 Lux (33,444fc) • Fixture Weight: 317.5 lbs./144 Kg. • Moment Load: 1,269.5 ft. lbs./1,720.2 N•m CEILING HEIGHT 9'-2" min. 10'-4" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-11 REV0 8/09 AUR575 2657mm 105" 1335mm 52 1/2" 945mm 37 1/4" 1140mm 45" 70mm 2 3/4" 1000mm 39 1/2" 1200mm 47 1/4" 360º 360º 360º 110º 360º 3/4" Diameter Conduit 110º 360º 1765mm 69 1/2" 360º 1969mm 77 1/2" Wall Control 360º 360º 2032mm 80" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 432 watts (1,469 BTU/hr) • Amperage: 4.8 amps • Intensity: 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) • Fixture Weight: 329.4 lbs./149.4 Kg. • Moment Load: 1,445.4 ft. lbs./1,958.5 N•m CEILING HEIGHT 9'-2" min. 10'-4" max. 425mm 16 3/4" 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-12 REV0 8/09 AUR57TV5 2657mm 105" 1335mm 52 1/2" 945mm 37 1/4" 1140mm 45" 1" Diameter Conduit 70mm 2 3/4" 1000mm 39 1/2" 1200mm 47 1/4" 360º 360º 360º 110º 360º 3/4" Diameter Conduit 110º 360º 1765mm 69 1/2" 360º CAMERA READY 1969mm 77 1/2" Wall Control Camera Control Connector 360º 360º 2032mm 80" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 432 watts (1,469 BTU/hr) • Amperage: 4.8 amps • Intensity: 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) • Fixture Weight: 334.9 lbs./151.9 Kg. • Moment Load: 1,485.2 ft. lbs./2,012.4 N•m 425mm 16 3/4" CEILING HEIGHT 9'-2" min. 10'-4" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-13 REV0 8/09 AUR575TV 2657mm 105" 1335mm 52 1/2" 945mm 37 1/4" 1140mm 45" 1" Diameter Conduit 70mm 2 3/4" 1000mm 39 1/2" 1200mm 47 1/4" 360º 360º 360º 110º 360º 3/4" Diameter Conduit 110º 360º CAMERA READY 1765mm 69 1/2" 360º 1969mm 77 1/2" Wall Control Camera Control Connector 360º 360º 2032mm 80" 610mm 24" TECHNICAL DATA • Electrical: 100-240 VAC, 50/60 Hz, 1 phase • Power Consumption: 432 watts (1,469 BTU/hr) • Amperage: 4.8 amps • Intensity: 4,000K=430,000 Lux (39,954fc) 4,500K=379,000 Lux (35,214fc) • Fixture Weight: 334.9 lbs./151.9 Kg. • Moment Load: 1,445.4 ft. lbs./1,958.5 N•m 425mm 16 3/4" CEILING HEIGHT 9'-2" min. 10'-4" max. 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 1.800.SKYTRON • 616.656.2900 • FAX 616.656.2906 TEC-B-0012-14 REV0 8/09 AURORA II WALL CONTROL FINISHED WALL NOTE: FRONT EDGE OF "BACK-BOX" MUST BE FLUSH WITH FINISHED WALL SURFACE 120VAC 30VDC 3/4" CONDUIT CONTROL BOX WITH RECESS MOUNT FLANGE INSTALLED CONDUIT CONNECTOR "BACK-BOX" DIMENSIONS SINGLE / DUAL 8-1/2"W x 11-5/8"H x 4"D TRIPLE 10-1/2"W x 14-1/2"H x 4"D RECESS DEPTH A (2) GROMMETS B FRONT PANEL ANCHOR (4) C RECESS MOUNT FLANGE V , 250 2A 0 0 ANCHOR (4) 1 1 2 3 4 ing t Act Fas 5 SCREW (4) V , 250 2A 2 IN MA 3 4 ing t Act Fas 5 E UR AT ER MP R TO R TECA LO DI CO IN OPTIONAL BACK-BOX INSTALLATION ED INAT UM N ILL HE KW 00 4,5 WER PO UR 0 HO R ,00 TO 20 DICA IN RECESS MOUNT FLANGE SCREW (4) RECESSED MOUNT DIMENSIONS A JUNCTION BOX D FRONT PANEL SINGLE OR DUAL TRIPLE 8" 10" B 4" 4" C 10" 13-1/2" D 6-7/8" 8-5/8" E 7-5/8" 11" F 5-7/8" 6-3/8" RECESS MOUNT FLANGE E 11-3/4"W x 14"H 13-3/4"W x 17-1/4"H 3" V , 250 2A 0 ANCHOR (4) 0 1 2 3 4 F ing t Act 5 Fas 3" V , 250 2A 1 2 IN 3 4 ing 5 t Act Fas 1" E UR AT ER MP R TO R TECA LO INDI CO ED INAT WER PO UM C N ILL MA HE KW 00 4,5 UR 0 HO R ,00 TO 20 DICA IN SCREW (4) SURFACE MOUNT TEC-B-0012-15 REV0 8/09 A SIDE VIEW BACK VIEW STANDARD MOUNTING STRUCTURE GUIDELINE TOP VIEW STIFFENER PLATE DETAIL 6" 12" STIFFENER PLATE (provided by others) Hole for Access to Fixture Junction Box 9-1/2" 6" 2" x 2" ANGLE SWAY BRACING 90° APART - 4 EACH (see note 2) 9-1/2" 12" Structural Ceiling 45° 45° (4) 2" x 2" Angle Sway Bracing (see note 2) 12" x 12" x 3/8" Stiffener Plate 3/4" Metal Flex Conduit (see note 3) Fixture Junction Box Finished Ceiling 1-3/8" 3/4" All Thread Rod 6" Max/ 4” Min. (see note 1) 2-1/4" ± 1/4" 15" dia. Mounting Plate (SKYTRON Supplied) 16-1/2" dia. Access Hole 18" dia. Ceiling Cover (SKYTRON Supplied) NOTES 1. 3/4" support rods located for total support of light, all labor and materials for fabrication supplied by General Contractor. 3/4" nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). 2. The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. 4. Optional Camera Ready Systems require a 1” diameter conduit from the fixture junction box to the camera control connector junction box. 65’ camera control cable with faceplate and connector supplied by SKYTRON. Conduit and 2” x 4” junction box supplied by General or Electrical Contractor. 5. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. TEC-B-0012-16 REV0 8/09 RECESSED MOUNTING STRUCTURE GUIDELINE TOP VIEW STIFFENER PLATE DETAIL 6" 12" STIFFENER PLATE (provided by others) Hole for Access to Fixture Junction Box 9-1/2" 6" 2" x 2" ANGLE SWAY BRACING 90° APART - 4 EACH (see note 2) 9-1/2" 12" Structural Ceiling 45° 45° (4) 2" x 2" Angle Sway Bracing (see note 2) 12" x 12" x 3/8" Stiffener Plate 3/4" Metal Flex Conduit (see note 3) Fixture Junction Box 3/4" All Thread Rod 6" Max/ 4” Min. (see note 1) Finished Ceiling 3/4" 1/4" 15" dia. Mounting Plate (SKYTRON Supplied) 16-1/2" dia. Access Hole 20-1/8" dia. Ceiling Cover (SKYTRON Supplied) NOTES 1. 3/4" support rods located for total support of light, all labor and materials for fabrication supplied by General Contractor. 3/4" nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). 2. The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. 4. Optional Camera Ready Systems require a 1” diameter conduit from the fixture junction box to the camera control connector junction box. 65’ camera control cable with faceplate and connector supplied by SKYTRON. Conduit and 2” x 4” junction box supplied by General or Electrical Contractor. 5. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. HEADROOM CLEARANCE INCREASE - 2" TEC-B-0012-17 REV0 8/09 SEISMIC APPLICATION MOUNTING STRUCTURE GUIDELINE SS-L TOP VIEW STIFFENER PLATE DETAIL Typical Mounting Structure Shown 6" Contact SKYTRON representative for Seismic Calculations if Applicable 12" STIFFENER PLATE (provided by others) Hole for Access to Fixture Junction Box 9-1/2" 6" ANGLE SWAY BRACING 90° APART - 4 EACH (see note 2) 9-1/2" 12" Structural Ceiling 45° 45° (4) Angle Sway Bracing (see note 2) 12” x 12” x 3/8” Stiffener Plate 3/4" Metal Flex Conduit (see note 3) Support Rods Finished Ceiling 1-3/8" Fixture Junction Box (see note 1) As Specified by Seismic calculations 2-1/4" ± 1/4" 18" dia. Mounting Plate (SKYTRON Supplied) B2-010-20 UNIVERSAL ADAPTER PLATE B9-210-44 CASTLE TYPE CEILING COVER 19" dia. Access Hole 20-1/8" dia. Ceiling Cover (SKYTRON Supplied) NOTES 1. Support rods as specified per seismic calculations are to be located for total support of light, all labor and materials for fabrication supplied by General Contractor. Nuts and washers for support of SKYTRON mounting plate supplied by contractor (8 ea. required). 2. The mounting structure must be attached to structural ceiling and BRACED TO ALLOW NO TWISTING OR LATERAL MOTION and shall be designed not to provide a degree of rotation greater than two-tenths of a degree at the mounting plate. 3. 3/4" metal conduit and minimum 12AWG wire size (3 wires per lighthead) required between fixture and SKYTRON supplied wall control. All metal conduit, wiring, and other electrical materials as well as installation labor for such materials associated with the installation of the SKYTRON surgical light to be provided by Electrical Contractor. All installations of SKYTRON surgical lights should be under the direct supervision of a SKYTRON representative. All wiring to be in accordance with local codes and by a certified electrician. 4. Optional Camera Ready Systems require a 1” diameter conduit from the fixture junction box to the camera control connector junction box. 65’ camera control cable with faceplate and connector supplied by SKYTRON. Conduit and 2” x 4” junction box supplied by General or Electrical Contractor. 5. CONTRACTOR HAS FINAL RESPONSIBILITY for the strength and stability of the Mounting Structure. This is a GENERAL GUIDELINE ONLY. TEC-B-0012-18 REV0 8/09 5085 Corporate Exchange Blvd. S.E. Grand Rapids, MI 49512 1.800.SKYTRON • 616.656.2906 • 616.656.2906
Similar documents
molescent biax 8 - Mole
LOCATION MOUNT: OmniMount with 11/8" receiver. LOCATION CABLE: Attached 12 ft., 18/3. STUDIO MOUNT: Yoke with 11/8" receiver. STUDIO CABLE: Detachable 10 ft., 18/3 power cables and a pass-thru powe...
More information