Cooper Fire Systems

Transcription

Cooper Fire Systems
Cooper Fire Systems
Emergency Voice Communication
The VoCALL
Emergency
Voice
Communication
Systems
Since its’ launch in 2003, the VoCALL Emergency Voice
Communication System (EVCS) has been used in some
of the world’s most prestigious sites, from Wimbledon
AELTCC and St Pancras stations in the UK to the
Marina Towers and Jumeirah Tunnel in the Middle East.
VoCALL suits all sizes of installation from one and two outstation
systems in small shops like Bon Marche, to massive 364 line dual
network system at Westfield shopping centre in London’s White City.
Allied to the fully compliant hardware, Cooper also offer software
packages such as VoCALL Site Installer, allowing global configuration
of the system from any exchange on the network, and the VoCALL
ReCALL, system, a real time incident and fault logging system, which
not only logs faults and the start and end of call incidents, it records
the conversation as well.
Standards Compliance
Designed from the outset to comply with BS5839 Pt9.
Scalable Solution
The Benefits
Outstations are common across the range and can be used on
both compact and network solution.
2
Cable Saving
By utilising a star topology for compact systems and a ring and
star topology for the network solution, outstations can be cabled in
low cost 2 core fire rated cables.
Space Saving
By distributing the network solution, no dedicated ‘comms’ room
is required, and the exchanges can be located in risers or utility
cupboards.
Highly Integrated
By allowing designers to choose the outstation type and mix any
type on a system, including emergency assistance alarms, all EVCS
and disabled calls can be managed from a single control location, or
in the case of the network solution up to 8 points.
Site Proven
With thousands of sites since the launch in 2003 you can be sure
of the systems reliability and longevity, all the firmware is flash™
based, making site upgrades to the latest version simple to
implement to add the latest software features.
Fire Telephones
Fire telephones are hardwired full duplex communications systems
with monitoring and battery backup, and are required in buildings
over 4 stories in many countries in the world (in the UK this is
governed by BS9999). These are provided as a backup to traditional
fireman’s radio systems, which can fail to operate in many high rise
environments due to the large amount of steel in the building, and
the “corona” effect of fire on radio broadcasts.
Fire telephones are also required in fire fighting lift lobbies when
these lifts are provided within a building. Fire telephones can also be
used for fire wardens to call the control point during fire drills and
primary evacuation phases before the fire services arrive and
assume control.
The Overview
Disabled Refuge Systems
Disabled refuge systems are required in the UK in all non domestic
premises over 1 story or where an emergency exit is by stairs (for a
full description see building regulations approved document B). A
disabled refuge is a relatively safe area within a building or exit
staircase where mobility impaired occupants can be placed (not just
wheelchair users) while the main building occupancy is evacuated,
allowing building management and emergency services to safely
assist these people from the building when stairwell crowding has
eased. Mobility impairment is defined as not being able to walk
200m continuously without aid, and includes arthritis sufferers,
people with leg and back injuries and women over 6 months term
pregnancy. A disabled refuge system is not just for use during a fire,
and must be available at all times.
Emergency Assist Alarm
An emergency assist alarm is defined in Building Regulations
Approved Document M, and must be provided at all disabled toilets
within a non domestic premises, if the toilet is in a non permanently
occupied space, remote indication must be provided at a central
control or monitoring point. An emergency assist alarm can only be
reset by attending the location of the call, so the reset point is within
the cubical, also allowing accidental calls to be cancelled by the
toilet occupier. The VoCALL
emergency assist alarm
system is powered from the
local exchange or compact
unit, and is fully monitored
over and above the
specification described in
BS8300.
3
Contents VoCALL - Emergency Voice Communication System
Page 5
Compact 5 Line Exchange Unit
CFVCC5
Page 7
Compact 9 Line Master
Exchange Unit
CFVCCM9
Page 9
Network 8 Line Exchange Unit
CFVCX8
Page 11
Network Master Handset
CFVCM and CFVCWM
Page 13
Type A Handset
CFVCSHP, CFVCFHP and
CFVCIPA
Page 15
Type B Handset
CFVCSHF, CFVCSHFG and
CFVCSHFSS
Page 17
Roaming Handset and Jack Plate
CFVCRHS and CFVCRJP
Page 19
VoCall Emergency Assist Alarm Kit
CFVCEA
4
VoCALL - Emergency Voice Communication System
Compact 5 Line Exchange Unit
CFVCC5 - Compact 5 Line Exchange Unit
Overview
The VoCAll compact 5 line exchange unit
(CFVCC5) is ideal for the smaller installations
which require just a limited number of
outstations and emergency assist alarms.
This system comprises of the 5 line exchange
unit and up to 5 outstations (type A, type B,
emergency assist alarms or in Far East and
Middle East applications jack plates). It
requires no programming and is simple to
install.
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The standard
states that were both systems are fitted to a
building these should form a single system.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
Features
•
•
•
•
•
•
•
•
BS5839 Pt9 compliant
Monitored handset
Monitored supply and charger
Up to 5 outstations
5 line keys, 1 fault accept
15 status LED’s
Full duplex system
Wall mount case
Benefits
• Simple cabling, outstations
connect directly into the
master using 2 core radial
fire rated enhanced cables.
• In addition to type A and
type B outstation the
CFVCC5 can also monitor
emergency assist alarms
(using a 2 core radial).
• No programming required,
panel is fitted with end of
line resistors which are
discarded when an
outstation or emergency
assist alarm is connected.
5
VoCALL Compact 5 Line Exchange Unit - CFVCC5
Full System Architecture
Technical Specification
Code
CFVCC5
Description
Compact 5 Line Exchange Unit
Standards
EMC: EN55103-1 & EN55103-2.
Product Family: BS5839 Pt9 & BS9999
Power Supply
Voltage
230V ac +/- 10% 50/60Hz
Internal Power Supply
14V dc
Supply and Battery
Monitored, open, short, fuses
Protection
Deep discharge, short, thermal
Battery Size and Type
1 x 12V 5Ah
Mains Fuse
240V 2A HRC
Battery Fuse
1A PTC
Charge Current
250mA (max)
Inputs
Number of lines
5
Remote Enable
Short to use
End of Line 1
10kΩ
Outputs
Number
2 (fault & in-use)
Type
Volt free relay
Contact
30V dc 1A
Controls
Buttons
5 zone keys, 1 acknowledge
Zone LEDs (x5)
1 line status,1 fault status
Fault LEDs
3 (ac, dc & general)
Outstation Cables
Type
Enhanced
Cores
2 Core (1mm or 1.5mm)
Distance
500m
Physical
Construction
Powder Coated Zintec
Dimensions (H x W x D)
300mm x 350mm x 90mm
Weight
6.5kg
Control and Design
The VoCALL compact 5 line exchange unit
(CFVCC5) is a self contained enclosure housing
a master handset, 5 line exchange, power
supply, and battery charger. It can be surface or
semi-flush mounted as standard.
The case is made from powder coated zintec,
with a smoked perspex door covering the
handset.
20mm cable knockouts are provided for all
necessary cables as well as space for the
backup 12V SLA battery.
The unit is microprocessor controlled, but
requires no programming on site; the panel is
fitted with end of line resistors which are simply
discarded when an outstation is connected.
Product Codes
Code
CFVCC5
6
Description
Compact 5 Line Exchange Unit
VoCALL - Emergency Voice Communication System
Compact 9 Line Master Exchange Unit
CFVCCM9 - Compact 9 Line Master Exchange Unit
Overview
Features
The VoCALL compact 9 line master exchange
unit (CFVCCM9) is ideal for small to medium
sized installations which don’t require the
complexity of a full network solution.
• BS5839 Pt9 compliant
• EN54 Pt4:A2 power supply
and charger
• 4 navigation keys
• 6 status LED’s
• 4 line, 20 character LCD
• Full duplex system
• Simple menu programming
• Wall mount case
This system comprises of the 9 line master
exchange unit and up to 9 outstations (type A,
type B, emergency assist alarms or in Far East
and Middle East applications jack plates).
Using the 10 line slave exchange unit
(CFVCCS10) this system can be easily
expanded to 19 lines.
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The standard
states that were both systems are fitted to a
building these should form a single system.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
Benefits
• Up to 19 outstations, using
10 line slave exchange unit
(CFVCCS10) the 9 line
master exchange unit can
be expanded up to 19 lines.
• In addition to type A and
type B outstation the
CFVCCM9 can also monitor
emergency assist alarms
(using a 2 core radial).
• 4 core is fire rated enhanced
cable used to connect
exchange unit to the slave.
7
VoCALL Compact 9 Line Master Exchange Unit - CFVCCM9
Full System Architecture
Technical Specification
Code
CFVCCM9
Description
Compact 9 Line Master Exchange Unit
Standards
EMC: EN55103-1 & EN55103-2
LVD: EN60950
Product Family: BS5839 Pt9 & BS9999
Power Supply
AC Input
230V ac +/- 10% 50/60Hz
Internal Supply
14V dc
Supply and Battery
Monitored open, short, fuses
Protection
Deep discharge, short thermal, impedence
Battery Type
1 x 12V VRSLA (7Ah required)
Mains Fuse
240V 1A HRC
Battery Fuse
250mA PTC
Charge Current
250mA
Inputs
Number of Lines
9
Remote Enable
Short to use
Outputs
Number
2 (fault & in-use)
Type
Volt free relay
Contact
30V dc 1A
Controls
Buttons
4 navigation keys
Display
4 lines, 20 characters
Status LED’s
3 (in-use, healthy & energised)
Fault LED’s
3 (line, PSU & general)
Outstation Cables
Type
Enhanced
Cores
2 Core (1mm or 1.5mm)
Distance
500m
Physical
Construction
Powder Coated Zintec
Dimensions (H x W x D)
300mm x 350mm x 90mm
Weight
6.5kg
Control and Design
The VoCALL compact 9 line master exchange
unit (CFVCCM9) is a self contained enclosure
housing a master handset, 9 line exchange,
power supply, and battery charger. It can be
surface or semi-flush mounted as standard.
The case is made from powder coated zintec,
with a smoked perspex door covering the
handset.
10 Line Slave
Exchange Unit
The 10 line slave exchange
unit (CFVCCS10) adds 10
additional lines to the compact
9 line master exchange unit
giving a total of 19 lines
available on a system.
20mm cable knockouts are provided for all
necessary cables as well as space for the
backup 12V SLA battery.
The unit is microprocessor controlled, with
simple menus, including a call log, fault log and
change log, all accessible from the front panel
navigation keys.
Product Codes
Code
CFVCCM9
CFVCCS10
8
Description
Compact 9 Line Master Exchange Unit
10 Line Slave Exchange Unit
VoCALL - Emergency Voice Communication System
Network 8 Line Exchange Unit
CFVCX8 - Network 8 Line Exchange Unit
Overview
Features
The VoCALL network 8 line exchange unit
(CFCVX8) is a small wall mounted unit which
can be distributed throughout a site and being
concealed from view in convenient locations
such places as rises, stairwells and cupboards.
• Can control up to 8
independent monitored lines
• Built in monitored 1A
charger for 12V SLA 5Ah
batteries
• 12 status LEDs
• Dry contact for fault or
‘in-use’ indication
• Serial port for configuration
or updates
• Dual network ports which
provide power for the
master handsets
• Full duplex system
• Compact design
Using this system greatly reduces the cabling
requirement and equipment ‘on view’ in such
key places as reception areas, making the
system aesthetically pleasing to the customer
as well reducing the cost of installation.
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The standard
states that were both systems are fitted to a
building these should form a single system.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
Benefits
• LED indication, for effective
& easy fault finding.
• Fault or ‘in-use’ relay, can
be connected to a fire panel
or BMS.
• Global configuration, upload
information quickly via a PC
using the serial port.
• Up to 32 distributed units on
any network, no central
exchange rack required.
9
VoCALL Network 8 Line Exchange Unit - CFVCX8
Full System Architecture
Technical Specification
Code
CFVCX8
Description
Network 8 Line Exchange Unit
Standards
EMC: EN55103-1 & EN55103-2
LVD: EN61000-3-2 & EN61000-3-3 & EN60950
Product Family: BS5839 Pt9 & BS9999 &
EN54 Pt4
Power Supply
Voltage
230V ac ± 20%
Current
11mA
Battery
12V SLA 5Ah
Charger
1A controlled impedance
Monitoring
Open, short & high impedance cell
Outstation Cables
Grade
Enhanced
Cable (per Leg)
1 off 2 core (twisted for MICC)
Distance (per Leg)
500M soft skin types, 300M MICC
Monitoring
DC open, short & earth
Network Cables
Type
Cores
Enhanced
1 off 4 pair (eg Draka 91-0245)
2 off 4 core 1mm CSA soft skin
4 off 1 pair MICC twisted
Distance
500M soft skin types, 300M MICC
Monitoring
Data and phantom voltage
Indication & Controls
Fault LEDs
10 off yellow
(general, PSU, 8 lines)
Status LEDs
2 off green
(ac & dc)
Settings
8 way DIP switch
Physical
Construction
Zintec, Texture Powder Coated, RAL 7032
Dimensions (H x W x D)
296mm x 210mm x 82mm
Weight
1.6kg
VoCALL Site Installer Software
Control and Operation
Wiring
The VoCALL site installer software allows for
global configuration of the system from any
exchange on the network.
Each network 8 line exchange unit (CFVCX8) sits
on a data highway and is locally powered, with
internal battery backup from a monitored,
maintained sealed lead acid battery.
Using network communications
combined with subscriber line
telephone techniques, a
VoCALL provides large scale
cable savings, while not
requiring a dedicated rack
room to house a central
exchange.
Up to 8 lines can be connected to each
distributed exchange, and each line is fully
monitored for open, short or earth faults.
Up to 32 CFVCX8 exchange units can be
attached to a VoCALL system giving a maximum
system size of 256 independent lines.
The compact case is made from powder coated
zintec and is fitted with 20mm cable knockouts
for all cables needed, and also provides space
for the system backup 12V SLA battery.
The network comprises a line
or ring of 8 cores, each leg can
be up to 500M depending on
cable type.
A ring topology is
recommended by BS5839 Pt9.
Line cables consist of a single
2 core enhanced cable, either
soft skin types or MICC and
only 1mm CSA is required.
Product Codes
Code
CFVCX8
CFVCSI
10
Description
Network 8 Line Exchange Unit
VoCALL Site Installer Software
VoCALL - Emergency Voice Communication System
Network Master Handset
CFVCWM - Network Master Handset, Wall Mounted
Overview
Features
The VoCALL network master handset can be
either desk (CFVCM) or wall (CFVCWM)
mounted.
• Up to 8 masters per system
• Controls up to 256 Lines
(32 CFVCX8 exchanges)
• Monitored handset
• Large high contrast display
(4 x 20 character)
• 12 key quick dial keypad
• Full duplex system
• Directory dial function
• Full system event log
(fault & configuration)
• 16 character unique name
per line
• Dual network ports
• Remote powered
Each system can have up to 8 master handsets
which gives great flexibility to the larger
installations allowing all calls to be monitored
from various control points. As an example, an
installation may have security offices requiring
a master handset, reception and numerous
entrances that need to be monitored.
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The
standard states that were both systems are fitted
to a building these should form a single system.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
Benefits
• Flexibility can be used as a
fire telephone system,
disabled refuge call system
or as a combined system.
• Global configuration, whole
site can be configured from
the master handset.
• Directory dialing, speed
dial and conference calling
• All hail function makes
testing the system simple.
11
VoCALL Network Master Handset - CFVCM / CFVCWM
Full System Architecture
Technical Specification
Code
Description
Standards
CFVCM
CFVCWM
Network Master handset, Desk Mount
Network Master handset, Wall Mount
EMC: EN55103-1 & EN55103-2
EMC: EN55103-1 & EN55103-2
Product Family: BS5839 Pt9 & BS9999
Product Family: BS5839 Pt9 & BS9999
Voltage
11V dc to 18V dc
11V dc to 18V dc
Current
88mA at 12V dc
88mA at 12V dc
Source
Network port x 2
Network port x 2
AVR RISK
AVR RISK
Power Supply
Processing
Architecture
16MHz
16MHz
Memory
4K ram, 20K EEProm, 128K flash
4K ram, 20K EEProm, 128K flash
Monitoring
125mS asynchronous watchdog
125mS asynchronous watchdog
checksum on EEPROM & flash
checksum on EEPROM & flash
Clock
Network Cables
Enhanced
Enhanced
1 off 4 pair (eg Draka 91-0245)
1 off 4 pair (eg Draka 91-0245)
2 off 4 core 1mm CSA soft skin
2 off 4 core 1mm CSA soft skin
Grade
Cable (per Leg)
Distance (per leg)
Monitoring
4 off 1 pair MICC twisted
4 off 1 pair MICC twisted
500M soft skin types, 300M MICC
500M soft skin types, 300M MICC
Data and phantom voltage
Data and phantom voltage
Indication & Controls
Fault LEDs
4 off yellow
4 off yellow
(general, panel, supply & exchange)
(general, panel, supply & exchange)
Status LEDs
LCD
4 off green
4 off green
(healthy, ac, dc & network)
(healthy, ac, dc & network)
High contrast blue/white LCD
High contrast blue/white LCD
4 line 20 character, 5 x 8 pixel format
4 line 20 character, 5 x 8 pixel format
Keyboard
12 key telephone style
12 key telephone style
Navigation
3 keys (down/left, accept, up/right)
3 keys (down/left, accept, up/right)
Physical
Construction
Base: Brushed Stainless Steel
Base: Brushed Stainless Steel
Lid: Zintec, Black Powder Coated
Lid: Zintec, Black Powder Coated
Sides: Aluminium, Black Powder Coated
Sides: Aluminium, Black Powder Coated
268mm x 275mm x 85mm
300mm x 350mm x 90mm
6.5kg
6.5kg
Dimensions (H x W x D)
Weight
VoCALL ReCALL Software
Control and Design
Wiring
The VoCALL ReCALL software is a real time
incident and fault logging system, which records
the start and end of any call, logs faults and any
conversations fully.
The network master handset has a clear 4 line
backlit display which shows the calling
outstation name in plain text, and calls can be
made to outstations by either dialling the
number of the unit, or choosing the name from
a text dialling directory.
Using network communications
combined with subscriber line
telephone techniques, a VoCALL
network provides large scale
cable savings, while not requiring
a dedicated rack room to house
a central exchange.
The case is made from stainless steel with
extruded aluminium rails. 20mm cable
knockouts are provided for all necessary
cables.
Product Codes
Code
CFVCM
CFVCWM
CFVCRM
CFVCLOG
12
The network comprises a line or
ring of 8 cores, each leg can be
up to 500M depending on cable
type.
A ring topology is recommended
by BS5839 Pt9. In line with the
recommendations of BS5839 Pt9
multiple master handsets can be
fitted to a VoCALL network (up to
8) with lockouts operating when
a multiple consoles are in use.
Description
Network Master Handset, Desk Mount
Network Master Handset, Wall Mount
19” 6u Rack Mount Kit for CFVCM only
VoCALL ReCALL Logging and Recording Software
VoCALL - Emergency Voice Communication System
Type A Handset
CFVCSHP - Type A Handset, Surface / CFVCFHP - Type A Handset, Flush
Overview
Features
The VoCALL type A handset is a compact unit
which offers easy access via a magnetic push
catch door. The flush (CFVCFHP) mountable
unit offers a unique front levelling system
allowing the back box to be mounted at a
slight angle whilst still retaining a true front
face and door. A surface (CFVCSHP)
mountable unit is also available.
•
•
•
•
The type A handset is compatible with all
VoCALL systems for use as a standard fire
telephone or disabled refuge call point.
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The
standard states that were both systems are fitted
to a building these should form a single system.
Compact design
High volume ringer
Status LED
Telecoil for hearing
impaired users
• Full duplex operation
• Magnetic push catch
• Stainless steel option
Benefits
• Versatility, the unit can be
used on all VoCALL systems.
• Dual use, the type A
handset can be used as a
fire telephone or a disabled
refuge call point.
• Magnetic push catch, for
quick and easy access.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
13
VoCALL Type A Handset - CFVCSHP / CFVCFHP / CFVCIPA
Technical Specification
CFVCSHP
CFVCFHP
CFVCIPA
Description
Type A Handset, Surface Mount
Type A Handset, Flush Mount
Type A Handset, Lockable Surface Mount
Standards
EMC: EN55103-1 & EN55103-2
EMC: EN55103-1 & EN55103-2
EMC: EN55103-1 & EN55103-2
LVD: EN60950
LVD: EN60950
LVD: EN60950
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Code
Outstation Cables
Grade
Enhanced
Enhanced
Enhanced
Cores
2 core 1mm or 1.5mm
2 core 1mm or 1.5mm
2 core 1mm or 1.5mm
500m
500m
500m
Distance
Physical
Construction
Dimensions (H x W x D)
Zintec, Powder Coated
Zintec, Powder Coated
Zintec, Powder Coated
300mm x 150mm x 75mm
320mm (bezel) x 150mm x 75mm
300mm x 200mm x 120mm
295mm (backbox) x 150mm x 75mm
Weight
1400g
1400g
Mounting The Unit
Suitability
All type A handsets should be mounted at a height
of either 1200mm from the floor, or on a 1400mm
centre line to comply with the requirements of
Building Regulations Document M (Access for the
Disabled).
All type A handsets are defined in BS5839 Pt9,
and can be used as a fire telephone or disabled
refuge call point.
CFVCSHP / CFVCIPA
The back box has 4 indented feet to allow
mounting on uneven walls.
CFVCFHP
A cut out of 300mm x 160mm is recommended,
the front bezel has adjustments to level the back
box on the wall.
If the units are to be used as a refuge point
suitable space must be allowed to the side of the
unit to allow a wheelchair to be parked for using
the system.
Surface Mount
75mm
2500g
When choosing the outstation type for use with
an EVCS we recommend reading section 11 of
BS5839 Pt9 2011 which deals with outstation
types, and states as follows:
11.1.a
Type A handsets should be used for evacuation
or fire fighting use, and a type B handsets
should only be used where a type A handsets
are impractical.
11.1.b
For disabled refuges type A or type B handsets
can be used, however in locations (section
11.6.k) type B handsets can only be used where
the background noise is below 40dBA (therefore
there can be no sounder or voice alarm
coverage in the area).
VoCALL handsets are designed for use by multidisability users, having high contrast signage in
line with RNIB guidelines and an induction loop
coil (to BSEN60118-4) in the handset.
155mm
320mm
295mm
Flush Mount
75mm
150mm
180mm
1400mm*
Product Codes
300mm
1400mm*
* Unit mounting height from floor level.
14
It is recommend that a type A handset is used in
most locations, otherwise you may have to
consider acoustic hoods or 2 outstations in each
location for compliance with the other
associated standards and laws, including
BS8300 and the Equality Act 2010.
Code
CFVCSHP
CFVCSHPSS
CFVCFHP
CFVCFHPSS
CFVCIPA
CFVCIPASS
CFVCHFS
Description
Type A Handset, Surface Mount (Red)
Type A Handset, Surface Mount (Stainless Steel)
Type A Handset, Flush Mount (Red)
Type A Handset, Flush Mount (Stainless Steel)
Type A Handset, Lockable Surface Mount (Red)
Type A Handset, Lockable Surface Mount (Stainless Steel)
Type A Handset, Uncased (for retro fit integration in to equipment)
VoCALL - Emergency Voice Communication System
Type B Handset
CFVCSHF / CFVCSHFG / CFVCSHFSS - Type B Handset
Overview
Features
The VoCALL type B handset is designed to be
versatile, compact and easy to use refuge call
point.
•
•
•
•
•
This unit can either be surface or flush mounted
using a simple to install bezel (CFVCFHB).
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The standard
states that were both systems are fitted to a
building these should form a single system.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
•
•
•
•
Compact design
High volume ringer
Status LED
20mm cable glands
Loop output for hearing
impaired users
Tactile braille signage
Full duplex operation
Flush bezel available
Stainless steel option
Benefits
• Versatility, the unit can be
used on all the VoCALL
systems.
• Full duplex operation,
allowing 2 way voice
communication.
• Tactile braille signage to
assist partially sighted
people to easily operate
refuge point.
15
VoCALL Type B Handset - CFVCSHF / CFVCSHFG / CFVCSHFSS
Technical Specification
Code
Description
Standards
CFVCSHFG
CFVCSHF
CFVCSHFSS
Type B Handset, Surface Mount
Type B Handset, Surface Mount
Type B Handset, Surface Mount
EMC: EN55103-1 & EN55103-2 LVD: EN60950
EMC: EN55103-1 & EN55103-2 LVD: EN60950
EMC: EN55103-1 & EN55103-2 LVD: EN60950
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Product Family BS5839 Pt9 & BS9999 & EN60118-4
Outstation Cables
Grade
Enhanced
Enhanced
Enhanced
Cores
2 core 1mm or 1.5mm
2 core 1mm or 1.5mm
2 core 1mm or 1.5mm
500m
500m
500m
2 off red ( ashes location lights, solid in use)
2 off red ( ashes location lights, solid in use)
2 off red ( ashes location lights, solid in use)
Press to call button
Press to call button
Press to call button
Press to cancel button
Press to cancel button
Press to cancel button
Construction
Zintec, Powder Coated
Zintec, Powder Coated
Zintec, Powder Coated
Colour Option
Green
Red
Stainless Steel
133mm x 133mm x 45mm
133mm x 133mm x 45mm
133mm x 133mm x 45mm
1105g
1105g
1105g
Distance
Indications & Controls
Status LEDs
Call
Cancel
Physical
Dimensions (H x W x D)
Weight
Mounting The Unit
Suitability
All type B handsets should be mounted at a height
of either 1200mm from the floor, or on a 1400mm
centre line to comply with the requirements of
Building Regulations Document M (access for the
disabled).
All type B handsets are defined in BS5839 Pt9,
and can be used as a fire telephone or disabled
refuge call point.
The back box has 4 indented feet to allow
mounting on uneven walls.
Type B handsets can be flush mounted by cutting
a hole 133mm x 133mm and 45mm deep, and
using the stainless steel bezel (CFVCFHB) to finish
the surround.
45mm
133mm
133mm
1400mm*
* Unit mounting height from floor level.
When choosing the outstation type for use with
an EVCS we recommend reading section 11 of
BS5839 Pt9 2011 which deals with outstation
types, and states as follows:
11.1.a
Type A handsets should be used for evacuation
or fire fighting use, and a type B handsets
should only be used where a type A handsets
are impractical.
11.1.b
For disabled refuges type A or type B handsets
can be used, however in locations (section
11.6.k) type B handsets can only be used where
the background noise is below 40dBA (therefore
there can be no sounder or voice alarm
coverage in the area).
VoCALL type B handsets are designed for use
by multi-disability users, having high contrast
signage in line with RNIB guidelines and a
socket for an external induction loop amplifier if
required.
Product Codes
Code
CFVCSHF
CFVCSHFG
CFVCSHFSS
CFVCFHB
16
Description
Type B Handset, Surface Mount (Red)
Type B Handset, Surface Mount (Green)
Type B Handset, Surface Mount (Stainless Steel)
Flush Mounting Bezel (Stainless Steel)
VoCALL - Emergency Voice Communication System
Roaming Handset and Jack Plate
CFVCRHS - Roaming Handset / CFVCRJP - Jack Plate
Overview
Features
The roaming handset (CFVCRHS) is used along
with the jack plate (CFVCRJP) for emergency
voice communication system installations in
countries whose fire codes allow for roaming
handsets (these units are not suitable for
installation in the UK under BS5839 Pt9).
• Flexible roaming phone
• Low noise high quality
telephone jack
• Telecoil for hearing
impaired users
• Full duplex operation
• Stainless steel jack plate
When used together the roaming handset and
jack plate form a type A handset which is
compatible with all VoCALL systems
Benefits
This VoCALL Emergency Voice Communication
System (EVCS) is designed to fully comply with
BS5839 Pt9 (abb. Pt9) for use as a fire telephone
system, disabled refuge call system or as a
combined system when both fire telephones and
disabled refuge points are required. The standard
states that were both systems are fitted to a
building these should form a single system.
• The jack plate can be
surface or flush mounted.
• Full duplex operation,
allowing 2 way voice
communication.
An EVCS is a fixed, monitored and maintained,
bi-directional, full duplex voice communication
system to assist the orderly evacuation of
disabled or mobility impaired people and
enhance fire fighters communication during
emergencies.
17
VoCALL Roaming Handset and Jack Plate - CFVCRHS / CFVCRJP
Technical Specification
Jack Plate
Code
CFVCRJP
Description
Jack Plate
Cables
Grade
Enhanced
Cores
2 core 1mm or 1.5mm
Distance
500M
Monitoring
dc open, short and earth
End Of Line
10K 1/4 W
Physical
Construction
Brushed Stainless Steal
Dimensions (H x W x D)
86mm x 86mm x 25mm
Weight
140g
Technical Specification
Roaming Handset
Code
CFVCRHS
Description
Roaming Handset
Standards
EMC: EN55103-1 & EN55103-2
LVD: EN60950
Controls
Call
Automatic “Off Hook” dialing
Connection
Jack
1/4” mono neutrik heavy duty
Physical
Construction
ABS UL90V1
Dimensions (H x W x D)
210mm x 66mm x 45mm
Weight
700g
Mounting The Unit
Suitability
The jack plate (CFVCRJP) should be mounted at
a height of either 1200mm from the floor, or on a
1400mm centre line to comply with the
requirements of Building Regulations Document
M (access for the disabled).
The roaming handset (CFVCRHS) and jack plate
(CFVCRJP) are suitable for EVCS installations in
countries whose fire codes allow for roaming
handsets, this is not suitable for installation in
the UK under BS5839 Pt9.
The jack plate fits on to a standard MK style
back box (not supplied) and can be flush or
surface mounted.
Jack Plate
25mm
86mm
86mm
1400mm*
* Unit mounting height from floor level.
Product Codes
Code
CFVCRJP
CFVCRHS
18
Description
Jack Plate
Roaming Handset
VoCALL - Emergency Voice Communication System
VoCALL Emergency Assist Alarm Kit
Coming
soon
2012
CFVCEA - VoCALL Emergency Assist Alarm Kit
Overview
Features
It has now become very common for the
disabled toilet to be specified as part of the
refuge system.
• Monitored to BS5839 Pt9
• Remote powered from
VoCALL exchange
• Dual loop pull cord
• High contrast labels
• Braille on cancel plate
• Blue indication
The CFVCEA has been specifically designed to
integrate disabled call functions into the
VoCALL network or VoCALL compact ranges
providing the perfect solution for conformity
with the Building Regulations Document M and
Equality Act 2010.
Disabled toilet alarms are required by Building
Regulation Document M, and by integrating it
with the Emergency Voice Communication
System all calls relating to disabled
communications can be displayed in a single
point.
The CFVCEA solution is fully monitored and
battery backed by the VoCALL system, saving
local power supplies and giving confidence in
the system integrity.
Benefits
• Saving power, no PSU is
required remote powered
by VoCALL system.
• One install saves running
2 separate systems.
• One location all calls from
disabled toilets and refuge
points monitored from one
location.
• Tactile braille signage to
assist partially sighted
people to easily operate the
cancel plate.
The CFVCEA shows up as a call on the VoCALL
system, but has no speech path so a
conversation cannot be had with the occupant,
use of the type B outstations would allow this.
19
VoCALL Emergency Assist Alarm Kit - CFVCEA
Technical Specification
Over Door Indicator
Code
CFEAODI
Description
Over Door Indicator
Specification
Operating Voltage
12V dc (nominal)
Physical
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 31.5
Technical Specification
Cancel Button
Code
CFEARSP
Description
Cancel Button
Specification
Operating Voltage
12V dc (nominal)
Physical
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 25
Technical Specification
Pull Cord Unit
Code
CFEAPULL
Description
Pull Cord Unit
Specification
Operating Voltage
12V dc (nominal)
Physical
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 30.5 (+cord)
Wiring Guide Using 2 Core Cable
VoCALL Emergency Assist Alarm Kit
VoCall
12V +
Exchange
+
+
Pull Cord Unit
OUT
VoCALL Exchange
Over Door Indicator
Cancel Unit
Over Door
Indicator
+
+
IN
Over Door Indicator
Cancel Unit
Pull Cord Unit
Cancel
Unit
+
-
Product Codes
Code
CFVCEA
Description
VoCALL Emergency Assist Alarm Kit
(1x Over Door Indicator, 1x Cancel Button, 1x Pull Cord Unit,
1x Disabled Sticker)
CFEAPULLKIT
Emergency Assist Alarm, Stand Alone Kit
(1x Power Supply Unit, 1x Over Door Indicator, 1x Cancel Button,
1x Pull Cord Unit, 1x Disabled Sticker)*
Also available
* For further information see www.cooperfire.com
20
Emergency Assist Alarm
Emergency Assist Alarm, Stand Alone Kit
CFEAPULLKIT - Emergency Assist Alarm, Stand Alone Kit
Overview
Features
The emergency assist alarm, stand alone kit
(CFEAPULLKIT) provides the perfect solution
for conformity with the Building Regulations
Document M and Equality Act 2010.
• Complies with regulations
& recommendations
• Dual loop pull cord
• High contrast labels
• Blue indication
This is a simple 2 wire system that has been
specifically designed to meet the needs of
disabled service users and conforms to all the
relevant requirements; Disability Rights
Commission code of practice, English Tourism
Council Recommendations and RNIB signage
guidelines.
Benefits
The use of combined high output blue LED
indication and buzzer ensures a response to the
call.
• Quick and simple
installation, with limited
cabling requirements.
• High contrast printing for
increased visibility.
• Tactile braille signage to
assist partially sighted
people to easily operate the
cancel plate.
The emergency assist alarm, stand alone kit
(CFEAPULLKIT) comprises of all the
components needed to install a fully compliant
system, with additional parts available
separately.
21
Emergency Assist Alarm, Stand Alone Kit - CFEAPULLKIT
Power Supply Unit
Technical Specification
Code
CFEAPSU
Description
Power Supply Unit
Specification
Mains
230V ac +10% -15%
Output
12V dc (nominal)
Physical
Over Door Indicator
Construction
PC
Dimensions (mm)
H 146 x W 86 x D 39
Technical Specification
Code
CFEAODI
Description
Over Door Indicator
Specification
Operating Voltage
12V dc (nominal)
Physical
Cancel Button
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 31.5
Technical Specification
Code
CFEARSP
Description
Cancel Button
Specification
Operating Voltage
12V dc (nominal)
Physical
Pull Cord Unit
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 25
Technical Specification
Code
CFEAPULL
Description
Pull Cord Unit
Specification
Operating Voltage
12V dc (nominal)
Physical
VoCALL Emergency Assist Alarm Kit
Construction
PC
Dimensions (mm)
H 87 x W 87 x D 30.5 (+cord)
Wiring Guide Using 2 Core Cable
Power
Supply
-
12V +
+
+
Pull Cord Unit
OUT
PSU 12V supply
Over Door Indicator
Cancel Unit
Over Door
Indicator
+
+
IN
Over Door Indicator
Cancel Unit
Pull Cord Unit
Cancel
Unit
+
-
Product Codes
Code
CFEAPULLKIT
CFEAPSU
CFEAODI
CFEARSP
CFEAPULL
CFEACORD
CFEASDS
22
Description
Emergency Assist Alarm, Stand Alone Kit
(1x Power Supply Unit, 1x Over Door Indicator, 1x Cancel Button,
1x Pull Cord Unit, 1x Disabled Sticker)
Emergency Assist Alarm Power Supply Unit
Emergency Assist Alarm Over Door Indicator
Emergency Assist Alarm Cancel Button
Emergency Assist Alarm Pull Cord Unit
Emergency Assist Alarm Pull Cord Accessory Pack
Emergency Assist Alarm Disabled Sticker (pack of 5)
Emergency Assist Alarm
4 Way Splitter Unit
CFEASL4 - 4 Way Splitter Unit
Overview
Features
The 4 way splitter unit CFEASL4 allows up to 4
stand alone disabled toilets to be monitored in
one specific area.
• Designed to comply with all
regulations and
recommendations
• High visibility
• More than one 4 way
splitter can be used
• Small compact design
Staff can then at the designated area such as a
reception or security desk react to an alarm
swiftly and efficiently.
Benefits
• Up to 4 disabled toilets
monitored in one area
• Uses blue LEDs to avoid
confusion
• Visibility to remote staffed
areas
• No mains or PSU required
at each disabled toilet
23
4 Way Splitter Unit - CFEASL4
Wiring Guide Using 2 Core Cable
Power
Supply
+
-
4 Way
Slave
Unit
-
12V +
+
+
Pull Cord Unit
+
+
+
+
+
Pull Cord Unit
+
-
Pull Cord Unit
Cancel
Unit
Over Door
Indicator
+
+
+
+
+
Cancel
Unit
Over Door
Indicator
+
+
+
+
Pull Cord Unit
Over Door
Indicator
Cancel
Unit
Over Door
Indicator
+
+
Cancel
Unit
+
-
Product Codes
Code
CFEASL4
24
Description
Emergency Assist Alarm 4 Way Splitter Unit
Index Emergency Voice Communication System
Part Code
Description
Page Number
CFEACORD
Emergency Assist Alarm Pull Cord Accessory Pack
19/21
CFEAODI
Emergency Assist Alarm Over Door Indicator
19/21
CFEAPSU
Emergency Assist Alarm Power Supply Unit
19/21
CFEAPULL
Emergency Assist Alarm Pull Cord Unit
19/21
CFEAPULLKIT
Emergency Assist Alarm, Stand Alone Kit
CFEARSP
Emergency Assist Alarm Cancel Button
19/21
CFEASDS
Emergency Assist Alarm Disabled Sticker (pack of 5)
19/21
CFEASL4
Emergency Assist Alarm 4 Way Splitter Unit
CFVCC5
Compact 5 Line Exchange Unit
5
CFVCCM9
Compact 9 Line Master Exchange Unit
7
CFVCCS10
10 Line Slave Exchange Unit
7
CFVCEA
VoCALL Emergency Assist Alarm Kit
19
CFVCFHB
Flush Mounting Bezel (Stainless Steel)
15
CFVCFHP
Type A Handset, Flush Mount (Red)
13
CFVCFHPSS
Type A Handset, Flush Mount (Stainless Steel)
13
CFVCHFS
Type A Handset, Uncased (for retro fit integration in to equipment)
13
CFVCIPA
Type A Handset, Lockable Surface Mount (Red)
13
CFVCIPASS
Type A Handset, Lockable Surface Mount (Stainless Steel)
13
CFVCLOG
VoCALL ReCALL Logging and Recording Software
11
CFVCM
Network Master Handset, Desk Mount
11
CFVCRHS
Roaming Handset
17
CFVCRJP
Jack Plate
17
CFVCRM
19” 6u Rack Mount Kit for CFVCM only
11
CFVCSHF
Type B Handset, Surface Mount (Red)
15
CFVCSHFG
Type B Handset, Surface Mount (Green)
15
CFVCSHFSS
Type B Handset, Surface Mount (Stainless Steel)
15
CFVCSHP
Type A Handset, Surface Mount (Red)
13
CFVCSHPSS
Type A Handset, Surface Mount (Stainless Steel)
13
CFVCSI
VoCALL Site Installer Software
CFVCWM
Network Master Handset, Wall Mount
CFVCX8
Network 8 Line Exchange Unit
21
23
9
11
9
25
Major Projects
Over the last 6 years Cooper VoCALL and voice alarm products have been installed on
several very high profile projects, the following is a small sample of these.
Wimbledon AELTCC
Supplied and commissioned a site
wide fire telephone and disabled
refuge system with over 130 points,
complete with audio recording and
logging software so the police can
review any incidents.
55 Broadway and Albany
House, London
Supplied and commissioned a touch
screen voice alarm and fire telephone
system for the buildings which house
London Underground’s Headquarters
and British Transport Police HQ.
Dublin Airport Terminal 2
Wimbledon
AELTCC
Supplied a fully distributed fibre optic
voice alarm system, the disabled
refuge and fire telephone system and
the various disabled toilet alarm
system.
3 and 4 More London
Supplied and commissioned the voice
alarm and the fire telephone systems
for More 3 and 4 buildings which are
part of the More London Estate,
beside the Mayors building on the
South Bank of the Thames.
Albany House,
London
26
St Pancras Station, London
Supplied Ashford, Stratford and
Ebbsfleet stations, with disabled refuge
systems for the Channel Tunnel
Extension. Following the installation
Network Rail Approval was granted.
Westfield Shopping Centre,
White City, London
Supplied and commissioned two
networks of disabled refuge and fire
telephones with over 300 points with
master controls in both the fire and
security control rooms.
Nuclear Power Station,
Hartlepool
St Pancras Station
Supplied and commissioned a dual ring
fibre optic linked voice alarm system
covering the whole site, additional dual
redundancy features were added with
special microphones for the Simulator
Training Suite.
Jumeirah Road Tunnel, ME
Linking the Palm Islands to mainland
Dubai, Cooper VoCALL products
supplied the emergency telephone
system in special stainless steel IP66
enclosures.
Centre Parcs, Elveden
Supplied and commissioned the
networked voice alarm system for the
village centre, following its reconstruction
after fire destroyed the original building.
Westfield Shopping
Centre, White City
27
Cooper Middle East
Abu Dhabi
P.O. Box 53234, Karama
Villa 4 opp. Govt. Dept. Sports
Association, Sector 2-17
Street 6 (off Delma St No. 13)
Abu Dhabi UAE
T: +971 2 446 6840
F: +971 2 446 6841
Qatar
Office No. 237, 2nd Floor Building
No. 81, 'D' Ring Road
Old Airport Area
P.O. Box 55582
Doha
Qatar
T: +974 5515 9948
Dubai
PO Box 30861
Suite 302, Building 49
Dubai Healthcare City
Dubai
United Arab Emirates
T: +971 4427 2500
F: +971 4429 8521
Saudi Arabia
P.O. Box 6315
3rd Floor Kaki Centre, Office 203
Tahlia Street (opposite IKEA)
21442 Jeddah
KSA
T: +966 2668 7703
F: +966 2663 6552
India
Cooper India Pvt. Ltd.
DLF Cyber City
Building 10A, Ground Floor
Sector 25, Gurgaon – 122002
India
T: +91 124 468 3888
Egypt
1169, Ministries Square
Sheraton Helipolis Area
Building 1, Cairo
Egypt
T: +202 2269 1134
F: +202 2269 1135
Australia
Cooper Industries Australia
P.O. Box 2577
205 – 209 Woodpark Road
Smithfield, N.S.W. 2164
Australia
T: +02 8787 2777
F: +02 9609 2342
Vietnam
Cooper Industries Vietnam
F4.1, 39 Nguyen
Thi Dieu St, ward 6
Dist. 03, Ho Chi Minh City
Vietnam
T: +848 6290 9639
F: +848 6290 6549
Cooper Safety Fire Systems
Cooper Lighting and Safety Ltd
Wheatley Hall Road
Doncaster
South Yorkshire
DN2 4NB
United Kingdom
Sales
T: +44 (0)1302 303 999
F: +44 (0)1302 303 333
E: [email protected]
Service
T: +44 (0)1302 303 352
F: +44 (0)1302 303 332
E: [email protected]
Technical and Quotations
T: +44 (0)1302 303 350
F: +44 (0)1302 303 332
E: [email protected]
Export
T: +44 (0)1302 303 344
F: +44 (0)1302 303 345
E: [email protected]
www.cooperfire.com
China
Cooper Electric (Shanghai) Co, Ltd.
3F, 9th Building, No. 6101
Longdong Avenue
East Area of Zhangjiang
High Tech Park, Pudong
Shanghai
China 201201
T: + 86 21 6891 9988
Conditions of sale
All goods supplied are subject to the company’s general conditions of sale which are available on request.
Trade Descriptions
All descriptions represent only particulars of the goods to which they apply and do not form part of any contract. The
company reserves the right to change specification without prior notification or public announcement.
®2011 Cooper Lighting and Safety
All rights reserved.
Publication reference: CFS0044-C-EVCS