Estimating Sheet - DECRA Shingle
Transcription
Estimating Sheet - DECRA Shingle
Estimating Sheet - DECRA Shingle - Direct to Deck Description (A) Project Name: Profile Date: Color Calculations Total Squares x 3 = BDLS (10-15% Waste Factor) DECRA Shingle Panel 15 panels per square 19-3/4” exposure – min pitch 4:12 Select Ventilation Calculator available at www.decra.com DECRA Shingle Panel Vent Select (B) Linear Feet ÷ 2 = Pieces Needed Shingle Hip & Ridge As needed for hip and ridge 25-3/4” Exposure Select Linear Feet Ridge ÷ 20 = Packages Needed DECRA Ridge Vent (2) 20’ rolls / package Ventilation Calculator available at www.decra.com (2) 2-1/2” W x 1” H x 20’ L (C) n/a Shingle Starter Clip w/ Drip Edge 10’ Length (D) (E) Shingle Short Course Clip n/a 10’ Length Use with standard drip edge & allow for 1” overlap if using as alternative starter. Linear Feet of Eave ÷ 10 = Pieces Needed Linear Feet Rake/Gable ÷ 6 = Pieces Needed (Includes 6” Overlap) Shingle Rake/Gable Channel For use along rakes/gables (Use standard drip edge as needed under channel) Linear Feet of Eave ÷ 10 = Pieces Needed (Allow for 1” Overlap) 6’6” Length Select Linear Feet ÷ 9.5 = Pieces Needed (x1) for sidewalls, including skylights and chimneys (Includes 6” overlap) (F) Shingle Roof-to-Wall n/a For use at roof to side walls 10’ Length (G) DECRA Low-Profile Debris Guard For use along rakes/gables, hips & valleys as needed (H) Linear Feet of Valley ÷ 6 = Pieces Needed (Includes 6” Overlap) Shingle Valley & Cap Sold separately (I) n/a (2) 2” W x 3/8” H x 50’ L 6’6” Length n/a 24-3/4” x 30” (Use with Non-Lead Pipe Jacks) 6’6” Length Flat Sheet Select Select 16” x 54” 2,000 / box #9 Hex (1/4” diameter) x 1-1/2” long Use fasteners of sufficient length to penetrate through the sheathing (deck) by at least 1/2” n/a 1 x 2 and or 2 x 2 Timber Battens (Non-Treated) 1 x 2s at ridges as needed n/a Touch-Up Kit or 5 lb. Bag of Chip Use at penetrations, transitions & panels 1 per Roof Penetration Linear Feet ÷ 6 = Pieces Needed (Includes 6” Overlap) Side Flashing Corrosion Resistant Screws Valley Cap (stonecoated) Select Shingle/XD® Underpan For use to counter flash side wall Linear Feet Rake/Gable ÷ 50 = Rolls Needed Linear Feet Hips/Valleys ÷ 50 (2) = Rolls Needed 1 Box (2,000 pcs) per 15 Squares Bag of stone chip & bottle of acrylic base coat Select or 5 lb. Bag of Chip Colors: Canyon Brown, Fawn Grey, Midnight Eclipse, Vintage Slate, Woodland Green *CONSULT LOCAL BUILDING CODES. **HIGH WIND AREAS REQUIRE ADDITIONAL FASTENERS. COPPER AND LEAD ACCESSORIES ARE NOT TO BE USED DUE TO DISSIMILAR METAL REACTION. This estimate is provided in good faith and should not be assumed to reflect the exact components required to roof this plan. DECRA Roofing Systems will not be held liable for the accuracy of this estimate. 98090189 – 03/15 DECRA Estimating Sheet Shingle Direct to Deck Shingle Starter Clip w/Drip Edge (C) Shingle Rake/Gable Channel(E) Existing or Roof-to-Wall Head Wall Flashing (C) Shingle Starter Clip with Drip Edge (along eave for starter) 10’ Lengths (D) Shingle Short Course Clip (short course or as alternative to Starter Clip along eave) 10’ Lengths Shingle Hip & Ridge (B) Slope Slope Shingle Roof-To-Wall Side Flashing (F) Chimney Saddle Shingle/XD® Underpan (I) ) p (H Ca & ) y (G alle V e ngl Shi Lower Roof Wall Shingle Roof-To-Wall (F) (E) Shingle Rake/Gable Channel (along rake/gable) 6’6” Lengths (F) Shingle Roof-To-Wall 10’ Lengths (G) Shingle Valley 6’6” Lengths Slope Field Panels (A) Field Panels (A) Gable Field Panels (A) Shingle Hip & Ridge (B) Shingle Starter Clip w/Drip Edge (C) Field Panels (A) H i p & Ri d g e ( B ) (B) Shingle Hip & Ridge (along hip and ridge) 25-3/4” Exposure Wall Roof-To-Wall (F) Chimney Shingle Starter Clip w/Drip Edge (C) (A) Shingle Field Panels (10-15% waste) 15 panels per square Field Panels (A) Shingle Rake/Gable Channel (E) Shingle Rake/Gable Channel (E) Slope Shi ngl eV alle y (G )& Shingle Rake/Gable Channel (E) www.decra.com Shingle Short Course Clip (D) Ca p (H ) Field Panels (A) ) Hip Sh le ing e (B & R ingle Sh Ridg idg & e( B) Hip Field Panels (A) Shingle Starter Clip w/Drip Edge (C) Shingle Starter Clip w/Drip Edge (C) Shingle Starter Clip w/Drip Edge (C) (H)Valley Cap 6’6” Lengths (I)Shingle/XD® Underpan 24-3/4” x 30” aTin Snips aTape Measure aTable Saw aCircular Saw aScrew Gun aSpray Paint aRoofing Grade Sealant/Adhesive aHand Seamer aGalvanized Pipe Jacks (No Lead) aFollow Local Code aUse 2 x 2s and 1 x 2s as needed to secure Hip & Ridge Pieces along hips and ridges. (Should equal the same linear footage as total Hip & Ridge Pieces; each Hip & Ridge Piece equals 25-3/4”) Above 12:12 pitch use two 2 x 2s Below 12:12 pitch use one 1 x 2 stacked on one 2 x 2 aOne layer of Underlayment is required. For Installation Questions Call DECRA Roofing Systems at 800-258-9740 98090189 – 02/13
Similar documents
Commercial Roofing
The stone coated finish has been enlarged to show more detail. Final color selection should be made from an actual product sample. Lifetime Limited Warranty*; 120 mph Wind Warranty; Highest Impact ...
More informationDECRA Shingle XD
Where possible, Roofing Grade sealant / adhesive should be covered by roofing materials or by a
More information