Estimating Sheet - DECRA Shingle

Transcription

Estimating Sheet - DECRA Shingle
Estimating Sheet - DECRA Shingle - Direct to Deck
Description
(A)
Project Name:
Profile
Date:
Color
Calculations
Total
Squares x 3 = BDLS
(10-15% Waste Factor)
DECRA Shingle Panel
15 panels per square
19-3/4” exposure – min pitch 4:12
Select
Ventilation Calculator
available at www.decra.com
DECRA Shingle Panel Vent
Select
(B)
Linear Feet ÷ 2 = Pieces Needed
Shingle Hip & Ridge
As needed for hip and ridge
25-3/4” Exposure
Select
Linear Feet Ridge ÷ 20 = Packages Needed
DECRA Ridge Vent
(2) 20’ rolls / package
Ventilation Calculator
available at www.decra.com
(2) 2-1/2” W x 1” H x 20’ L
(C)
n/a
Shingle Starter Clip w/ Drip Edge
10’ Length
(D)
(E)
Shingle Short Course Clip
n/a
10’ Length
Use with standard drip edge & allow for 1”
overlap if using as alternative starter.
Linear Feet of Eave ÷ 10 = Pieces Needed
Linear Feet Rake/Gable ÷ 6 = Pieces Needed
(Includes 6” Overlap)
Shingle Rake/Gable Channel
For use along rakes/gables
(Use standard drip edge as needed under channel)
Linear Feet of Eave ÷ 10 = Pieces Needed
(Allow for 1” Overlap)
6’6” Length
Select
Linear Feet ÷ 9.5 = Pieces Needed
(x1) for sidewalls, including skylights and chimneys
(Includes 6” overlap)
(F)
Shingle Roof-to-Wall
n/a
For use at roof to side walls
10’ Length
(G)
DECRA Low-Profile Debris Guard
For use along rakes/gables, hips & valleys as needed
(H)
Linear Feet of Valley ÷ 6 = Pieces Needed
(Includes 6” Overlap)
Shingle Valley & Cap
Sold separately
(I)
n/a
(2) 2” W x 3/8” H x 50’ L
6’6” Length
n/a
24-3/4” x 30”
(Use with Non-Lead Pipe Jacks)
6’6” Length
Flat Sheet
Select
Select
16” x 54”
2,000 / box
#9 Hex (1/4” diameter) x 1-1/2” long
Use fasteners of sufficient length to penetrate
through the sheathing (deck) by at least 1/2”
n/a
1 x 2 and or 2 x 2 Timber Battens
(Non-Treated)
1 x 2s at ridges as needed
n/a
Touch-Up Kit or 5 lb. Bag of Chip
Use at penetrations, transitions & panels
1 per Roof Penetration
Linear Feet ÷ 6 = Pieces Needed
(Includes 6” Overlap)
Side Flashing
Corrosion Resistant Screws
Valley
Cap (stonecoated)
Select
Shingle/XD® Underpan
For use to counter flash side wall
Linear Feet Rake/Gable ÷ 50 = Rolls Needed
Linear Feet Hips/Valleys ÷ 50 (2) = Rolls Needed
1 Box (2,000 pcs) per 15 Squares
Bag of stone chip & bottle of acrylic base coat Select
or 5 lb. Bag of Chip
Colors: Canyon Brown, Fawn Grey, Midnight Eclipse, Vintage Slate, Woodland Green
*CONSULT LOCAL BUILDING CODES. **HIGH WIND AREAS REQUIRE ADDITIONAL FASTENERS. COPPER AND LEAD ACCESSORIES ARE NOT TO BE USED DUE TO DISSIMILAR METAL REACTION.
This estimate is provided in good faith and should not be assumed to reflect the exact components required to roof this plan. DECRA Roofing Systems will not be held liable for the accuracy of this estimate.
98090189 – 03/15
DECRA Estimating Sheet Shingle Direct to Deck
Shingle Starter Clip w/Drip Edge (C)
Shingle Rake/Gable Channel(E)
Existing or Roof-to-Wall
Head Wall Flashing
(C) Shingle Starter Clip with Drip Edge
(along eave for starter)
10’ Lengths
(D) Shingle Short Course Clip
(short course or as alternative to
Starter Clip along eave)
10’ Lengths
Shingle Hip & Ridge (B)
Slope
Slope
Shingle Roof-To-Wall
Side Flashing (F)
Chimney Saddle
Shingle/XD®
Underpan (I)
)
p (H
Ca
&
)
y (G
alle
V
e
ngl
Shi
Lower Roof
Wall
Shingle Roof-To-Wall (F)
(E) Shingle Rake/Gable Channel
(along rake/gable)
6’6” Lengths
(F) Shingle Roof-To-Wall 10’ Lengths
(G) Shingle Valley
6’6” Lengths
Slope
Field Panels (A)
Field Panels (A)
Gable
Field Panels (A)
Shingle Hip & Ridge (B)
Shingle Starter Clip w/Drip Edge (C)
Field Panels (A)
H i p & Ri d g e ( B )
(B) Shingle Hip & Ridge
(along hip and ridge)
25-3/4” Exposure
Wall
Roof-To-Wall (F)
Chimney
Shingle Starter Clip w/Drip Edge (C)
(A) Shingle Field Panels
(10-15% waste)
15 panels per square
Field Panels (A)
Shingle Rake/Gable Channel (E)
Shingle Rake/Gable Channel (E)
Slope
Shi
ngl
eV
alle
y (G
)&
Shingle Rake/Gable Channel (E)
www.decra.com
Shingle Short Course Clip (D)
Ca
p (H
)
Field Panels (A)
)
Hip Sh
le
ing e (B
& R ingle
Sh Ridg
idg
&
e(
B)
Hip
Field Panels (A)
Shingle Starter Clip w/Drip Edge (C)
Shingle Starter Clip w/Drip Edge (C)
Shingle Starter Clip w/Drip Edge (C)
(H)Valley Cap
6’6” Lengths
(I)Shingle/XD® Underpan
24-3/4” x 30”
aTin Snips
aTape Measure
aTable Saw
aCircular Saw
aScrew Gun
aSpray Paint
aRoofing Grade Sealant/Adhesive aHand Seamer aGalvanized Pipe Jacks (No Lead)
aFollow Local Code
aUse 2 x 2s and 1 x 2s as needed to secure Hip & Ridge Pieces along hips and ridges. (Should equal the
same linear footage as total Hip & Ridge Pieces; each Hip & Ridge Piece equals 25-3/4”)
Above 12:12 pitch use two 2 x 2s
Below 12:12 pitch use one 1 x 2 stacked on one 2 x 2
aOne layer of Underlayment is required.
For Installation Questions Call DECRA Roofing Systems at 800-258-9740
98090189 – 02/13

Similar documents

Commercial Roofing

Commercial Roofing The stone coated finish has been enlarged to show more detail. Final color selection should be made from an actual product sample. Lifetime Limited Warranty*; 120 mph Wind Warranty; Highest Impact ...

More information

DECRA Shingle XD

DECRA Shingle XD  Where possible, Roofing Grade sealant / adhesive should be covered by roofing materials or by a