18134c Bulletin A-157-K
Transcription
18134c Bulletin A-157-K
Power Roof Ventilators Upblast Hooded Recirculating Smoke Ventilators Series 61 & 63 Series 69 & 69S Series 15, 16 & 17 Series 71J, 73J & 75J Series 26 & 27 Series 69H LT WITH HONOR BUI HAR T , INC P I Q UZELL FANU S A A, OHIO HARTZELL ® Hartzell Fan, Inc., Piqua, Ohio 45356 www.hartzellfan.com Bulletin A-157-K November 2005 Index Upblast Roof Ventilator – Series 61 (Direct Drive), Series 63 (Belt Drive) Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 5 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 6 Upblast Roof Ventilator – Series 69 & 69S (Belt Drive, Motor Out of Airstream) Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 9 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 12 Upblast Roof Ventilator – Series 69H Smoke Ventilator Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 14 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 15 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 16 Hooded Roof Ventilator – Series 15 (Direct Drive), Series 16 (Belt Drive), Series 17 (Reversible) Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 17 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 18 Direct Drive Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 19 Belt Drive Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 20 Reversible Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 21 Filtered Unit Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 22 Filtered Unit Performance – Direct Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 23 Filtered Unit Performance – Belt Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 24 Hoodjet Roof Ventilators – Series 71J, 73J & 75J Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 25 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 26 Recirculating Roof Ventilators – Series 26 & 27 Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 27 & 29 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 28 & 30 Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 28 & 30 Roof Ventilator Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 31 Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 33 & 34 Bulletin A-157-K 2 www.hartzellfan.com 1 (800) 336-3267 Certified Ratings for Sound and Air Performance Hartzell Fan, Inc. certifies that the Belt Drive Upblast Roof Ventilator, Series 69, on pages 9, 11, 12 and 13 and Belt Drive Upblast Smoke Ventilator, Series 69H, on pages 14-16, are licensed to bear the AMCA Seal for air and sound. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-157 for Series 69 and #SD-159 for Series 69H. Power Roof Ventilator Selection The Hartzell Power Roof Ventilator performances on the following pages are based on standard air conditions (sea level, 70°F., and 29.92 inches barometric pressure). Performance data does include drive losses on belt drive units. Be sure to include fan model, performance requirements, operating temperature, motor data (enclosure, voltage, mounting position, etc.) and a list of required accessory items. (See pages 22 and 23.) Refer to pages 31 and 32 for more detailed information on Roof Ventilator Application. For upblast ventilators, refer to CFM limitations on pages 8 and 13. When placing your order, be sure to specify the Hartzell Model Code. The following example demonstrates our coding system. The illustrated Series Number specifies a Hartzell Series 61 Fan. Contact your local Hartzell Sales Representative for assistance. Hartzell Model Explanation A 6 1– G –3 6 3 – L – – – S T A O G 4 Motor RPM/Phase 3 Phase 2 = 3450 3 = 1750 4 = 1140 5 = 870 6 = 690 7 = 575 Type A – Production Item S – Stock Item Q – Special Quote Product Series Duty (G or H) Size (nominal wheel diameter, inches) No. of Blades Wheel Code Blade Angle, no decimal (applies to adjustable pitch fans only) Material of Construction Motor Enclosure Motor Horsepower Motor RPM/Phase 1 Phase B = 3450 C = 1750 D = 1140 E = 870 F = 690 G= 575 Motor Horsepower Horsepower Code Letter 1 4 / 1 3 / 1 2 / 3 4 / D E F G 1 H 11/2 I 2 J 3 K 5 L 71/2 M 10 N 15 O 20 P 25 Q 30 R 40 S 50 T 60 U How To Use Model Code Index: Example – Assume a needed performance of 8,400 CFM at 0" S.P.W.G. at standard conditions is required for an exhaust application. Reading the rating table on page five; a 24", series 61, direct drive upblast roof ventilator operating at 8380 CFM at 0" SP. It is also determined from the rating table the ventilator will consist of the following: standard construction, 1140 RPM totally enclosed air over motor, and a three blade lo-noise propeller. Knowing this the model code can be constructed as follows: the fan is a direct drive upblast roof ventilator, therefore, the series is “61”, “G” (General Industrial) Duty construction; the size is “24”; the propeller is a lo-noise, therefore, blade is “L”; the construction is standard, therefore, material is “ST”, the motor is a totally enclosed air over, therefore, the enclosure is “AO”, the horsepower required is .68 BHP, therefore, the horsepower code is “G”, and the motor RPM is 1140, therefore, the RPM code is “4”. Note: 1) All other informational fields must be filled with hyphens/dashes (–) if they are not applicable to the fan being considered. This bulletin lists Hartzell’s line of Power Roof Ventilators and accessories. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for assistance. Visit our website (www.hartzellfan.com) or call toll-free for the name of your Hartzell representative… 1-800-336-3267 Bulletin A-157-K 3 www.hartzellfan.com 1 (800) 336-3267 Upblast (Direct Drive & Belted) • • Series 61 “G” Duty Shown • • Series 63 “H” Duty Shown • Series 61 – Direct Drive The Series 61 upblast ventilator meets the need for an economical, yet efficient upblast roof ventilator. The Series 61 unit combines the Hartzell ring fan concept with a windband and butterfly damper. Dampers open automatically when the fan goes on, close weathertight when the fan is shut down. When the unit is in operation, the force of the discharge air effectively prevents the entry of rain or snow. • • Series 63 – Belted The belted upblast ventilator, Series 63, offers the same design and efficient performance as the direct drive model, along with the added dividend of an economical approach to a low speed, quiet upblast roof ventilator. The belted arrangement eliminates the need for costly, low-speed motors for direct drive operation. Since the drive assembly is in the ventilator’s airstream, the unit should not be used to handle high temperatures or dirt-laden air. • • Features: • Sizes – Direct Drive (Series 61) – 12"-72"… performance from 1,390 to 88,000 CFM at free air. Belted (Series 63) – 24"- 84"… performance from 5,080 to 124,500 CFM at free air. • Construction – steel construction is standard; aluminum construction is available for “H” Duty only. Sizes through 60" include painted, galvannealed weather exposed components. • • On sizes 66" and larger, windband and panel are painted hot rolled steel with industrial grade enamel. Motor base is heavy gauge plate, welded to solid steel rod frame. Motor Mount – “G” (General Industrial) Duty construction features an adjustable steel motor base and tubular steel frame, which are over-sized to provide structurally rugged construction. “G” Duty is available as Series 61 and 63 in sizes 18" to 48" and will be limited by HP and RPM on certain sizes. Please reference the performance rating tables, the shaded models are those models offered as “G” Duty. “H” (Heavy Industrial) Duty construction features solid rolled rod supports, welded to the fan panel and motor mounts to provide support for the motor. The steel motor base and solid steel support rods are oversized to provide structurally rugged construction. “H” Duty is available in all sizes and models. Propellers – cast aluminum airfoil type. SERIES 61 – DIRECT DRIVE – Sizes: 12" - 44" – 6-blade, Type P 12" - 14" – 4-blade, Type O 16" - 40" – 4-blade, Type W 20" - 60" – 3-blade, lo-noise, Type L 20" - 60" – 2-blade, Type N 48" - 72" – 4-blade adjustable, Type A 60" – 4-blade adjustable, Type AW 60" – 4-blade adjustable, Type BA SERIES 63 – BELTED – Sizes: 24" - 60" – 3-blade lo-noise, Type L 54" - 60" – 6-blade adjustable, Type AW 66" – 4-blade adjustable, Type BA 72" - 84" – 4- and 6-blade adjustable, Type A Note: The above adjustable blades are merely a representative group of blades available. Many other adjustable blades and blade angles can be furnished. Contact your Hartzell representative for assistance. Motors – totally enclosed air over motors are standard. Special motors are available upon request. Drive Assembly – Belted Only – drives are constant speed and are sized to handle 20% or more horsepower than the catalog motor is rated. Orifice Panel – sizes 12"- 60"… features painted galvannealed steel venturi panel. Sizes 66"- 84"… formed steel panel with angle ring orifice. Windband – rolled, welded construction. Windband effectively prevents wind resistance against the operation of the ventilator. A rolled angle on top and bottom of the windband is standard to provide additional support. Removable windband for ease of maintenance of motor and drive assembly is standard through 60". Dampers – semicircular lids at the base of the windband are mounted on corrosive resistant stainless steel rods which turn in plastic bearings. Bearings will not rust or stick, and require no lubrication. Lids open automatically when the fan turns on, closes weathertight when the fan shuts off. Damper lids on all sizes are constructed of galvanized steel as standard. Aluminum and fiberglass damper lids are also available. See Page 7 for CFM Limitations for Damper Lid Operation. Coatings – special coatings are available upon request. Extended Lube Tubes – will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings). Pre-Assembled Units – 12" to 60" shipped in one piece. 66" through 84", the stack cap is shipped separately. Options and Accessories – see pages 33 and 34. Bulletin A-157-K 4 www.hartzellfan.com 1 (800) 336-3267 Dimensions -GA. WINDBAND ROLLED FLANGE BOTH ENDS I.D. AIRFLOW RUBBER "U" MOLD (NOT SHOWN) 3/4 EXTERNAL LUBE TUBES (OPTIONAL) MAX. GA. SQUARE INSIDE Series 61 Principal Dimensions – Series 61 and 63 (Inches) Max Motor Frame Size 61 63 F max 61 Fan Size A 12 14 16 18 20 24 28 32 36 40 44 48 54 60 66 72 84 18 20 22 24 26 30 34 38 44 48 52 56 62 68 761⁄2 821⁄2 95 B D 22 12 24 12 26 12 28 20 30 20 36 20 42 20 42 26 48 26 50 26 54 38 581⁄4 38 641⁄4 38 701⁄4 38 793⁄4 365⁄8 853⁄4 365⁄8 981⁄4 425⁄8 63 J K Weight (less motor and options) 61 63 “G” Duty “H” Duty “G” Duty “H” Duty G Galv Alum Galv Alum “G” Duty “H” Duty “G” Duty “H” Duty Galv Alum 143⁄4 -143⁄4 -143⁄4 -223⁄4 101⁄2 223⁄4 101⁄2 231⁄2 101⁄2 231⁄2 123⁄4 291⁄2 123⁄4 291⁄2 151⁄2 291⁄2 151⁄2 411⁄2 18 421⁄2 18 421⁄2 -421⁄2 -405⁄8 -405⁄8 -465⁄8 -- 12 12 12 12 12 111⁄2 11 11 141⁄2 195⁄8 195⁄8 185⁄8 211⁄8 211⁄8 28 291⁄2 -- -----121⁄2 121⁄2 121⁄2 151⁄2 151⁄2 141⁄2 141⁄2 ------ -----151⁄8 161⁄4 181⁄4 177⁄8 181⁄4 225⁄8 215⁄8 211⁄2 211⁄2 44 44 49 2 2 2 2 2 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 33⁄4 33⁄4 33⁄4 4 4 4 14 14 14 14 14 14 14 14 14 14 14 14 14 14 1 ⁄4 1 ⁄4 1 ⁄4 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.375 0.375 0.375 20 20 20 20 20 20 20 20 20 20 16 16 16 14 10 10 10 0.064 0.064 0.064 0.064 0.064 0.064 0.064 0.064 0.064 0.064 0.100 0.100 0.100 0.100 0.190 0.190 0.190 ---56 143T 145T 145T 184T 213T 215T 254T 254T ------ 56 56 56 56 145 184T 184T 184T 215T 256T 256T 256T 286T 286T 326T 365T -- -----56 56 145T 145T 182T 184T 184T ------ -----145T 145T 184T 184T 184T 215T 215T 256T 256T 256T 286T 324T 44 50 51 77 85 124 135 169 175 227 275 409 628 640 484 1150 -- 33 37 38 57 63 93 101 126 126 170 165 263 432 437 363 862.5 -- E Galv Alum ----------117 88 124 93 210 157 191 143 241 181 217 163 291 218 586 440 486 364 532 399 966 724.5 1447.7 1085.78 NOTE: Dimensions and specifications are subject to change. Certified prints are available. Maximum installation weight less motor and any optional equipment. -GA. WINDBAND I.D. ROLLED FLANGE BOTH ENDS AIRFLOW RUBBER "U" MOLD (NOT SHOWN) EXTERNAL LUBE TUBES (OPTIONAL) 3/4 MAX. GA. SQUARE INSIDE Series 63 Bulletin A-157-K 5 www.hartzellfan.com 1 (800) 336-3267 Performance Rating Table – Series 61 – Direct Drive Size 12" 14" 16" 18" 20" 24" 28" 32" 36" 40" 44" 48" No. of Blades 6 4 6 4 6 4 8 4 4 4 3 4 2 2 2 6 6 4 3 4 2 2 2 6 6 3 4 2 2 2 3 4 4 2 2 6 2 3 6 4 3 4 2 6 6 2 6 3 4 4 2 2 6 2 2 6 3 4 3 2 2 2 4 2 4 3 4 6 Blade P O P O P W Q WB WA WA L W NA NB NC PA PB W L W NA NB NC PB PA L W NB NA NA L W W NC NB PA NA L PB W L W NA PA PB NA PA L W W NB NA P NB NA P L W L NC NB NA AA NA AA L AA AA Blade Angle 20° 19° 23° 24.5° Motor HP Code 1/4 D 1/4 D 1/4 D 1/4 D 1/4 D 1/4 D 1/4 D 1/3 E 1/2 F 1/4 D 1/2 F 3/4 G 1/4 D 1/2 F 3/4 G 1 H 11/2 I 2 J 1/3 E 1/2 F 1/2 F 3/4 G 1 H 11/2 I 2 J 3/4 G 1 H 1 H 2 J 1/2 F 11/2 I 2 J 1 H 2 J 3 K 5 L 1 H 2 J 3 K 5 L 1 H 11/2 I 2 J 3 K 5 L 1 H 11/2 I 2 J 3 K 11/2 I 2 J 3 K 5 L 1 H 11/2 I 2 J 3 K 5 L 11/2 I 2 J 3 K 5 L 71/2 M 2 J 3 K 5 L 2 J 3 K Motor RPM Code 3450 2 1725 3 1725 3 1725 3 1725 3 1725 3 1725 3 1725 3 1740 3 1185 4 1725 3 1725 3 1725 3 1725 3 1725 3 1750 3 1750 3 1750 3 1140 4 1140 4 1725 3 1725 3 1750 3 1750 3 1750 3 1140 4 1160 4 1750 3 1750 3 1140 4 1160 4 1160 4 870 5 1750 3 1750 3 1750 3 1160 4 1160 4 1160 4 1160 4 870 5 870 5 1160 4 1160 4 1160 4 870 5 870 5 870 5 870 5 690 6 1160 4 1160 4 1160 4 870 5 870 5 870 5 870 5 870 5 690 6 1160 4 1160 4 1160 4 1160 4 870 5 870 5 870 5 690 6 690 6 Peak Fan BHP .22 .10 .08 .17 .17 .27 .26 .37 .35 .12 .47 .74 .28 .56 .80 1.12 1.50 2.06 .30 .57 .45 .72 1.00 1.52 2.03 .68 1.11 1.00 2.02 .55 1.53 2.2 .93 2.01 2.82 4.82 1.12 2.33 2.43 3.83 .98 1.64 2.25 2.90 4.90 .94 1.25 1.90 3.47 1.67 2.17 3.50 5.20 .98 1.53 2.16 3.20 5.10 1.49 2.15 3.12 5.37 8.47 2.18 3.27 4.42 2.20 3.30 0" 1832 1390 1705 2110 2520 3040 3240 3850 4055 2765 4665 5900 5120 6630 7400 8100 9060 10380 5375 6800 7420 9280 9850 10300 12080 8380 10400 11820 15320 9930 12630 15170 11410 17270 20020 22650 14800 17700 18600 22000 13400 16610 20630 22200 25900 15550 16650 19230 23380 18300 23070 27050 29600 17730 20410 21900 24850 30770 19380 25500 28950 34350 25450 30030 31250 26500 29830 1/8" 1725 1177 1440 1820 2250 2780 2945 3520 3750 4290 5540 4150 5830 6740 7680 8700 9960 4750 6140 6320 8350 8990 9830 11600 7680 9670 10620 14370 8400 11750 14370 10270 15910 18850 22000 13500 16830 17750 21150 12250 15370 19000 20950 25000 13270 14900 18000 22150 16600 20800 25150 28500 14600 17970 20300 23550 29450 17700 23200 26600 32500 39650 22900 27950 29600 23900 27700 CFM @ SP 1/4" 1615 3/8" 1400 1/2" 1155 2500 2490 3225 3475 3975 5200 3490 4800 4980 6000 7230 8300 9550 5000 6770 7850 9100 6310 7250 8630 5400 7300 8050 9360 11100 6900 8920 9330 13330 5930 7000 8850 10560 5900 8170 7650 12250 10900 13550 9100 14470 17600 21300 11800 15900 16500 20250 10900 13970 17200 19600 24100 9930 12800 7900 11700 12900 16600 20500 10970 15250 19550 14930 15200 19400 13800 13700 18200 11950 15150 18150 23050 16300 21850 12850 16630 20700 14650 18400 23150 27300 15200 18600 22100 27800 15650 20700 24200 30400 38100 19750 25700 27850 20700 25100 15050 19000 8300 10000 11000 12000 15050 21200 26000 18900 24650 16600 20600 26150 18750 24400 17750 21400 28100 36500 18000 25550 34700 22750 26100 18600 24100 20600 Net Inst. Weight # 55 60 60 66 60 67 87 91 95 82 103 119 123 131 139 155 163 167 150 163 138 138 150 174 178 165 158 201 213 189 241 249 229 222 250 282 226 248 382 322 278 290 312 356 381 292 260 340 364 378 341 377 389 345 353 359 385 421 365 419 431 447 596 455 523 543 539 546 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 6 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 61 – Direct Drive (Cont’d.) Size 54" 60" 66" 72" No. of Blades 2 2 2 2 4 4 6 4 6 2 2 2 2 2 2 4 4 3 4 4 3 4 4 4 4 4 4 4 4 4 4 4 4 Blade NB NA NC NC BA BA BA BA BA ND NB NC NA NC BA BA BA L BA BA L AW BA BA BA BA BA BA AA AA AA AA AA Blade Angle 11° 16.5° 17.5° 14° 17.5° 15° 13° 16.5° 10° 16.5° 25° 12° 16° 20° 10° 16° 21 14° 19° 14° 19° 23° Motor HP Code 3 K 5 L 71/2 M 3 K 5 L 71/2 M 10 N 3 K 5 L 3 K 5 L 71/2 M 10 N 3 K 5 L 71/2 M 10 N 15 O 3 K 5 L 71/2 M 10 N 71/2 M 10 N 15 O 3 K 5 L 71/2 M 10 N 15 O 5 L 71/2 M 10 N Motor RPM Code 1160 4 1160 4 1160 4 870 5 870 5 870 5 870 5 690 6 690 6 1160 4 1160 4 1160 4 1160 4 870 5 870 5 870 5 870 5 870 5 690 6 690 6 690 6 690 6 870 5 870 5 870 5 690 6 690 6 690 6 870 5 870 5 690 6 690 6 690 6 Peak Fan BHP 2.85 5.04 7.12 3.15 5.50 8.20 11.00 3.35 5.50 3.80 5.15 7.20 10.00 3.00 5.60 8.40 10.90 13.80 3.30 5.45 7.00 10.90 7.80 11.25 15.00 3.15 5.60 8.15 10.90 16.80 5.45 8.40 11.20 0" 31950 40000 44700 33550 35950 43100 47900 31550 38100 38000 44200 50700 57000 38200 45630 50400 56750 63000 35830 44970 50000 59000 59300 68800 77500 43300 54600 63400 73200 88000 58700 69700 77300 1/8" 28900 37500 42300 30300 33400 40800 45750 28350 35150 32750 41600 47900 53800 33800 42100 48250 54500 61000 32100 41900 47500 56600 55500 65300 74000 39300 50700 60000 68600 83800 52000 63800 72100 CFM @ SP 1/4" 25500 34750 39800 26550 28500 38100 43350 30600 27700 37800 44500 49800 28700 38150 45700 52050 58900 28100 38900 45000 54100 51700 61700 70500 34500 46900 55800 63000 79000 44300 57600 66300 3/8" 1/2" 31900 37000 21600 22050 33000 39500 28700 34150 23250 32000 20900 33500 41250 44950 29300 36800 40500 33300 42850 49500 56750 26650 39350 46800 55000 34850 42200 51500 48000 57800 67200 26600 39000 48600 43800 53900 62600 42700 51700 57000 73200 38400 47300 50000 65500 46700 54500 38000 42200 Net Inst. Weight # 580 612 640 604 652 692 715 684 776 625 649 685 721 649 677 777 905 929 785 797 829 912 730 780 830 700 730 780 1341 1278 1328 1349 1400 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Rating Table – Series 63 – Belted Size 24" 28" 32" 36" 40" 44" No. of Blades 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Blade L L L L L L L L L L L L L L L L L L L L L L Motor HP Code 1/3 E 1/2 F 1/3 E 1/2 F 3/4 G 1/2 F 3/4 G 1 H 11/2 I 2 J 3/4 G 1 H 11/2 I 2 J I H I 11/2 2 J 3 K 11/2 I 2 J 3 K 5 L Motor RPM Code 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 1750 3 Peak Fan BHP .33 .52 .32 .52 .76 .51 .75 1.02 1.51 1.98 .77 1.07 1.68 2.08 1.17 1.67 2.31 3.30 1.53 2.00 3.02 4.95 Fan RPM 1071 1220 883 1035 1165 825 945 1045 1190 1305 764 837 980 1050 690 780 870 980 680 738 853 1010 0" 5080 5780 6400 7500 8470 8850 10100 11180 12710 13940 11640 12760 14930 16000 15280 17230 19200 21610 19440 21070 24300 28800 1/8" 4380 5170 5410 6680 7740 7620 9090 10280 11900 13200 10300 11520 13930 15080 13680 15820 17900 20500 17750 19550 23000 27700 CFM @ SP 1/4" 3/8" 1/2" 4500 5780 6960 6000 7940 9250 11050 12430 8050 10140 11630 8850 10770 11350 12820 11140 11600 14870 17980 16400 15150 19750 25150 17650 23530 10080 12800 14030 11600 14220 16500 19260 15420 17600 21500 26600 Net Inst. Weight # 139 139 151 151 155 213 217 225 245 245 238 262 266 266 312 320 332 356 385 389 401 417 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. All belt drive fan ratings include drive losses. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 7 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 63 – Belted (Cont’d.) Size 48" 54" 60" 66" 72" 84" No. Of Blades 3 3 3 3 3 3 3 3 4 4 3 3 3 3 3 4 4 4 4 4 4 4 4 4 6 6 6 6 4 4 4 6 4 6 4 Blade L L L L L L L L AW AW L L L L L AW AW BA BA BA BA BA AA AA AA AA AA AA BA BA BA BA BA BN BN Blade Angle 22° 22° 25° 25° 22° 22° 22° 22° 22° 22° 16° 22.5° 16° 25° 25° 16° 17° 21° 25° 27° 30° 29° Motor HP Code 1 H 2 J 3 K 5 L 2 J 3 K 5 L 71/2 M 5 L 71/2 M 3 K 5 L 71/2 M 10 N 15 O 71/2 M 10 N 3 K 5 L 71/2 M 10 N 15 O 5 L 71/2 M M 71/2 10 N 15 O 20 P 5 L 71/2 M 10 N 15 O 20 P 15 O 20 P Motor Peak Fan RPM Code BHP 1750 3 .98 1750 3 2.02 1750 3 2.93 1750 3 5.06 1750 3 1.87 1750 3 3.00 1750 3 4.86 1750 3 7.83 1750 3 5.31 1750 3 8.02 1750 3 3.00 1750 3 5.10 1750 3 7.50 1750 3 10.00 1750 3 14.90 1750 3 7.85 1750 3 10.60 1750 3 3.30 1750 3 5.60 1750 3 8.20 1750 3 11.00 1750 3 16.06 1750 3 5.50 1750 3 7.81 1750 3 8.15 1750 3 11.00 1750 3 16.80 1750 3 21.40 1750 3 5.83 1750 3 8.30 1750 3 11.20 1750 3 16.23 1750 3 22.00 1750 3 16.23 1750 3 21.73 Fan RPM 525 660 740 895 497 573 671 786 645 737 496 595 672 747 858 603 665 486 575 652 720 818 531 690 531 690 637 690 455 500 500 455 546 364 455 0" 19000 23600 26400 31930 26050 30000 35150 41200 38500 42950 35100 42000 47500 52850 60750 51200 56400 45800 54400 61400 68000 60300 64700 67200 71300 85700 74300 84000 94500 105700 117700 110000 1/8" 21600 24550 30400 22950 27400 33050 39350 36400 42200 31750 39300 45000 50700 58750 48800 54400 40600 50000 57800 64500 74000 53500 59300 61700 67200 81300 88800 66800 77500 88000 100000 112000 104500 118400 CFM @ SP 1/4" 19100 22500 28800 24000 30600 37400 33900 40150 27400 36300 42400 48400 56700 46000 52000 34200 45300 53800 61000 71300 38000 52000 54000 62000 76600 84500 59000 70200 81500 94000 105800 98000 112500 3/8" 1/2" 20100 27100 25250 27300 35250 32500 37950 32400 39400 45750 54600 42500 49200 35700 53000 52400 33500 45600 39500 49400 57300 67800 43700 53000 64500 41500 55700 70800 79500 48500 64500 73700 88000 99000 90600 106000 53600 63600 80500 91000 98000 Net Inst. Weight # 455 459 475 491 564 584 604 632 605 655 665 685 745 765 832 745 765 688 700 727 748 795 1204 1224 1244 1284 1296 1351 1672 1806 1840 1978 1978 2032 2002 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. All belt drive fan ratings include drive losses. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. CFM Limitations for Damper Lids Operation Series 61 and 63 CFM Minimum ① Maximum ➁ 12 1110 2725 14 1490 3670 ① Minimum CFM to open lids 16 1930 4750 18 2425 5975 20 2980 7335 24 4255 10475 28 5760 14175 Fan Size 32 36 7490 9445 18435 23250 40 11630 28630 44 14040 34560 48 16680 41055 54 21255 52315 60 26170 64410 66 30885 76025 72 84 36755 50030 90480 123150 ➁ Maximum CFM to prevent lid damage Bulletin A-157-K 8 www.hartzellfan.com 1 (800) 336-3267 Upblast (Belt Drive) Features: • Sizes – 12" through 84"… performance from 1,455 to 117,000 CFM at free air. • Construction – sturdy, three-piece unit. Fan is heavy gauge • Series 69 • Hartzell Fan, Inc. certifies that the Series 69, Belt Drive Upblast Roof Ventilator, shown hereon are licensed to bear the AMCA Seal for air and sound. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311, and comply with the requirements of the certified Ratings Program. Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-157. • • • The Series 69 roof ventilator meets the need for a heavy-duty belt drive, upblast ventilator with the motor out of the airstream. This unit features a belt drive duct fan mounted on a spun venturi panel with a stack cap backdraft damper. It is of sufficient height to ensure projection of air and exhaust fumes up and away from the roof of the building. The Series 69 upblast roof ventilator can be built with most of Hartzell’s tubeaxial fans. NOTE: Many other selections not cataloged in this rating table are available. Contact your local Hartzell representative for selections and assistance. • • • painted hot rolled steel, as standard construction. Aluminum construction is available. Seams are continuously welded. Curb panel features a venturi orifice to provide minimal entry losses and permit efficient fan operation. Venturi panel is painted galvannealed steel. Panel and fan are bolted together for ease of installation and maintenance. Stack cap is constructed of galvannealed steel in sizes 12" through 60" with self formed flanges top and bottom for additional strength; painted hot rolled steel, size 66" and larger. Butterfly dampers open when the unit is on, close weathertight when the unit is off. Discharge airstream prevents entry of rain or snow during operation. A rolled angle ring on top of the windband is standard on sizes 44" and larger to provide additional support. Damper lids are constructed of galvanized steel for all sizes as standard; aluminum and fiberglass lids are available. Lifting eyes are standard. Coatings – standard finish is an industrial grade enamel suitable for interior or exterior industrial applications. Other coatings are available upon request. Propellers – cast aluminum airfoil type. Sizes: 18" - 48" – 6-blade, Type W Sizes: 54" - 60" – 3-blade lo-noise, Type L Size: 66" – 4-blade adjustable, Type BA Sizes: 72" - 84" – 4- and 6-blade adjustable, Type A Note: The above blades are merely a representative group of possible selections for these ventilators. Many other fixed and adjustable pitch blade selections can be furnished. Contact your Hartzell representative for assistance. Pre-Assembled Units – 12" to 48" shipped in one piece. 54" through 84", stack cap is shipped separately. Motors – open drip proof are standard. Special motors are available upon request. Motor covers and drive guards are available. Motors are mounted out of the airstream. Drive Assembly – variable pitch drives are standard on units up to 10 HP, enabling speed reduction of 20% from the maximum fan RPM setting. Drives are sized for continuous duty. Propeller shaft rotates in two ball-type bearings mounted on structural inner steel support. Drive Protection – drive components (belts, sheave, shaft and bearings) are enclosed in an inner drum and protected from the airstream. This casing is positioned on the negative air pressure side of the propeller. Access to shaft and bearings is through a removable bearing cover. Shaft seal and cover plate are standard. Lubrication Tubes – extended from the bearings through the belt tube to the exterior of the fan housing. This standard feature permits easy maintenance. Options and Accessories – see pages 33 and 34. Bulletin A-157-K 9 www.hartzellfan.com 1 (800) 336-3267 Upblast (Belt Drive-Motor Out of Airstream) Easy Access Swingout construction provides easy, safe access to internal fan components for inspection, cleaning, maintenance or repair without removing the entire fan assembly or having personnel working directly over the roof opening. Fan housing is split and swings out from the assembly on a heavy duty hinge. Fan motor, propeller, drive shaft, bearings and drive components all swing out for easy access. Applications – – – – – Pulp & Paper Mills Paint Room Exhaust Automotive Weld Smoke Any application conducive to particulate build-up on airstream fan components. – Applications requiring routine washdown. Features • Performance – Fan sizes 12" through 60"… performance from 1,465 to 64,075 CFM at free air. See performance tables on pages 12 & 13; for performance at other operating points contact your Hartzell representative. • Construction – Same as Series 69 (see preceding page) with heavy-duty hinge mounting of fan motor, propeller & drive components. Standard unit construction is painted steel; aluminum or stainless steel construction available as an option. • Accessories – In addition to standard accessories (see pages 33 & 34), swingout fans are available with an optional wheeled support jack for ease of opening/ closing fan housing and De-Sta-Co clamps for ease of closing/opening swing out door. • Dimension Note – See dimensions table on page 11. Note that an additional 10" must be added to overall unit height for swingout construction. Series 69S – Swingout Construction (OPTIONAL ALUMINUM HOUSING SHOWN) Bulletin A-157-K 10 www.hartzellfan.com 1 (800) 336-3267 Dimensions Series 69S (Available Sizes 12"-60") Standard Series 69 INSIDE GA. MAT'L. * SUPPORT JACK (OPTIONAL) AIRFLOW GA MAT'L. LIFTING LUGS STANDARD GA. MAT'L. I.D. PIVOT POINT B.C. SQ. INSIDE Principal Dimensions – Series 69 FAN SIZE A B C D E F G H* 12 14 16 18 20 24 28 30 32 36 40 42 44 48 54 60 66 72 84 127⁄8 147⁄8 167⁄8 187⁄8 207⁄8 247⁄8 287⁄8 307⁄8 33 37 41 427⁄8 45 491⁄8 553⁄8 613⁄8 67 73 851⁄4 155⁄8 175⁄8 195⁄8 215⁄8 235⁄8 291⁄8 331⁄8 351⁄8 371⁄4 413⁄8 453⁄8 471⁄4 493⁄8 531⁄2 605⁄8 665⁄8 731⁄4 791⁄4 915⁄8 145⁄8 165⁄8 185⁄8 205⁄8 223⁄8 267⁄8 307⁄8 33 35 39 431⁄2 45 471⁄2 515⁄8 575⁄8 635⁄8 711⁄2 763⁄4 883⁄4 22 24 26 28 30 36 42 42 42 48 50 54 54 581⁄4 641⁄4 701⁄4 793⁄4 82 981⁄4 12 12 12 20 20 201⁄2 201⁄2 201⁄2 261⁄2 261⁄2 261⁄2 261⁄2 381⁄2 381⁄2 381⁄2 381⁄2 363⁄8 363⁄8 423⁄8 2 2 2 2 2 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 23⁄4 33⁄4 33⁄4 33⁄4 3 3 33⁄4 18 20 22 24 26 30 34 36 38 44 48 50 52 56 62 68 761⁄2 821⁄2 95 379⁄16 383⁄16 413⁄16 495⁄16 553⁄16 5713⁄16 585⁄16 615⁄16 675⁄16 675⁄16 755⁄16 761⁄16 881⁄8 891⁄8 893⁄8 897⁄8 823⁄8 823⁄8 883⁄8 J K L STEEL ALUM. STEEL ALUM. STEEL ALUM. 12 12 12 12 12 10 10 10 10 10 10 10 10 10 10 10 10 10 10 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 .190 3 ⁄16 3 ⁄16 3 ⁄16 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 1 ⁄4 1 ⁄4 1 ⁄4 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 1 ⁄8 3 ⁄8 3 ⁄8 3 ⁄8 20 20 20 20 20 20 20 20 20 20 20 20 16 16 16 14 10 10 10 .064 .064 .064 .064 .064 .064 .064 .064 .064 .064 .064 .064 .100 .100 .100 .100 .190 .190 .190 1 1 MOTOR FRAMES MAX 145T 145T 182T 213T 213T 215T 215T 215T 215T 215T 215T 215T 215T 215T 286T 286T 326T 326T 326T Note: Specifications and dimensions are subject to change. Certified prints are available. Sizes 66"-84" units are supplied with a flat curb panel. *For swing-out design, add 10". Not available for 66" thru 84". Bulletin A-157-K 11 www.hartzellfan.com 1 (800) 336-3267 Performance Rating Table – Series 69 – Belt Drive Size 12" 14" 16" 18" 20" 24" 28" 30" 32" 36" 40" No. of Blades Blade HP 6 W 1 6 W 1 6 W 3 6 W 1 6 W 1 6 W 3 Motor Code Motor RPM Code Peak Fan BHP Fan RPM 0" 1/8" CFM @ SP 1/4" 3/8" ⁄3 E 1750 3 .33 2315 1455 1315 1150 ⁄2 F 1750 3 .50 2650 1665 1545 1410 1245 ⁄4 G 1750 3 .75 3030 1905 1800 1685 1565 ⁄3 E 1750 3 .33 1980 2015 1850 1655 1/2" *Net Inst. Weight # 151 147 1415 154 160 ⁄2 F 1750 3 .50 2270 2310 2165 2010 1830 1600 157 ⁄4 G 1750 3 .75 2595 2640 2515 2385 2235 2075 164 6 W 1 ⁄2 F 1750 3 .50 2010 2920 2685 2480 2230 6 W 3 ⁄4 G 1750 3 .75 2300 3340 3135 2945 2765 2530 168 175 6 W 1 H 1750 3 1.10 2610 3790 3610 3440 3280 3115 181 6 W 1 ⁄2 F 1750 3 .50 1590 3425 3205 2925 2520 6 W 3 ⁄4 G 1750 3 .75 1820 3925 3730 3515 3225 2855 202 6 W 1 H 1750 3 1.10 2065 4450 4285 4105 3890 3615 203 6 W 11⁄2 I 1750 3 1.65 2365 5095 4950 4805 4635 4440 6 W 1 ⁄2 D 1750 3 .50 1355 3805 3505 3173 6 W 3 ⁄4 F 1750 3 .77 1555 4366 4105 3833 3521 3118 256 6 W 1 H 1750 3 1.13 1765 4956 4726 4493 4241 3956 264 6 W 11⁄2 I 1750 3 1.69 2020 5672 5471 5270 5062 4837 6 WB 1 ⁄2 F 1750 3 .50 1025 5300 4730 195 213 256 274 299 6 WB 3 ⁄4 G 1750 3 .75 1185 6130 5645 5090 4255 6 WB 1 H 1750 3 1.10 1345 6955 6530 6075 5530 6 WB 11⁄2 I 1750 3 1.65 1540 7965 7595 7215 6790 6295 317 6 WB 2 J 1750 3 2.20 1700 8795 8460 8120 7750 7355 327 6 WB 9195 8875 6 W 3 K 1750 3 3.29 1950 10085 9800 9500 3 ⁄4 G 1750 3 .75 905 7780 6985 6295 299 4685 307 363 377 6 W 1 H 1750 3 1.10 1030 8855 8140 7535 6855 5960 6 W 11⁄2 I 1750 3 1.65 1190 10230 9595 9050 8530 7920 385 395 6 W 2 J 1750 3 2.20 1320 11350 10775 10255 9790 9315 395 6 W 3 K 1750 3 3.30 1525 13115 12605 12140 11720 11310 424 6 W 1 H 1750 3 1.10 865 9130 8370 7555 6 W 11⁄2 I 1750 3 1.65 990 10450 9780 9110 8280 7030 440 6 W 2 J 1750 3 2.20 1090 11505 10900 10285 9650 8710 440 6 W 3 K 1750 3 3.30 1250 13195 12660 12130 11605 11035 470 6 W 5 L 1750 3 5.50 1490 15730 15280 14840 14400 13945 6 W 1 H 1750 3 1.11 785 10345 9425 8400 431 482 478 6 W 11⁄2 I 1750 3 1.64 895 11795 10995 10135 9185 7500 6 W 2 J 1750 3 2.19 985 12980 12260 11500 10670 9750 488 488 6 W 3 K 1750 3 3.28 1130 14895 14260 13620 12930 12200 517 6 W 5 L 1750 3 5.52 1355 17860 17325 16810 16260 15695 6 W 1 H 1750 3 1.11 670 12290 11015 9500 529 552 6 W 11⁄2 I 1750 3 1.65 765 14030 12940 11645 10350 6 W 2 J 1750 3 2.19 840 15405 14425 13300 12075 562 6 W 3 K 1750 3 3.32 970 17790 16945 16040 6 W 5 L 1750 3 5.53 1165 21370 20665 19950 6 W 71⁄2 M 1750 3 6.93 1265 23200 22550 21905 21210 20460 6 W 11⁄2 I 1750 3 1.63 660 15505 14430 13205 11625 10880 562 14995 13945 591 19170 18305 603 631 798 6 W 2 J 1750 3 2.21 730 17150 16185 15140 13880 12290 6 W 3 K 1750 3 3.31 845 19855 19015 18140 17195 16090 798 827 6 W 5 L 1750 3 5.52 1020 23965 23270 22580 21845 21085 839 6 W 71⁄2 M 1750 3 8.25 1180 27725 27125 26525 25910 25280 867 Performance certified is for Installation Type A: Free Inlet, Free Outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes transmission losses. Performance ratings do not include the effects of appurtenances (accessories). *For optional swing-out design weight, contact factory. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 12 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 69 – Belt Drive (Cont’d.) Size 42" 44" 48" 54" 60" 66" 72" 84" Blade Angle Motor Motor Peak Fan HP Code RPM Code BHP Fan RPM CFM @ SP 1/4" *Net Inst. Weight # No. of Blades Blade 6 W 11⁄2 I 1750 3 1.65 605 16495 15110 13615 6 W 2 J 1750 3 2.22 670 18265 17020 15705 14300 6 W 3 K 1750 3 3.31 775 21130 20055 18950 17780 16560 6 W 5 L 1750 3 5.51 930 25355 24455 23555 22630 21655 882 6 W 71⁄2 M 1750 3 8.29 1075 29310 28525 27755 26975 26165 910 6 W 10 N 1750 3 10.20 1155 31490 30760 30045 29315 28585 6 W 2 J 1750 3 2.20 655 20145 18805 17355 15595 0" 1/8" 3/8" 1/2" 841 841 869 930 883 6 W 3 K 1750 3 3.33 760 23370 22220 21035 19710 18160 6 W 5 L 1750 3 5.54 915 28140 27180 26225 25220 24135 912 924 6 W 71⁄2 M 1750 3 8.31 1060 32595 31760 30950 30110 29240 952 6 W 10 N 1750 3 9.71 1120 34440 33650 32880 32095 31285 6 W 2 J 1750 3 2.20 585 22420 20490 18630 971 1027 6 W 3 K 1750 3 3.27 670 25680 23975 22345 20690 18670 6 W 5 L 1750 3 5.51 810 31045 29615 28245 26935 25585 1039 1031 6 W 71⁄2 M 1750 3 8.17 935 35835 34600 33390 32245 31090 1059 6 W 10 N 1750 3 10.94 1040 39860 38700 37680 36600 35540 3 L 3 K 1750 3 3.27 590 33445 29985 26920 23220 1076 1154 3 L 5 L 1750 3 5.54 710 40250 37260 34700 32115 29050 1166 3 L 71/2 M 1750 3 8.30 820 46485 43820 41520 39355 37090 1194 3 L 10 N 1750 3 10.94 905 51305 48830 46700 44715 42745 1214 3 L 15 O 1750 3 11.50 920 52155 49710 47615 45650 43710 1261 3 L 5 L 1750 3 5.50 595 45935 41945 38150 34250 30020 1358 3 L 71⁄2 M 1750 3 8.17 685 52880 49330 46095 42750 39345 1386 3 L 10 N 1750 3 10.93 760 58670 55400 52510 49525 46485 1406 3 L 15 O 1750 3 14.00 830 64075 61005 58370 55680 52920 4 BA 22° 5 L 1750 3 5.6 575 54400 50000 45300 39500 4 BA 22° 71⁄2 M 1750 3 8.2 652 61400 57800 53800 49400 43700 4 BA 22° 10 N 1750 3 11 720 68000 64500 61000 57300 53000 1948 4 BA 22° 15 O 1750 3 16.06 818 74000 71300 67800 64500 1995 4 AA 17.5° 5 L 1750 3 5.5 584 60000 53000 42500 4 AA 16° 71⁄2 M 1750 3 7.81 690 64700 59300 52000 41500 4 AA 20° 10 N 1750 3 10.8 690 74100 68800 62500 51500 40500 6 AA 21.5° 15 O 1750 3 16.5 690 85000 81000 76500 71000 62000 6 AA 25° 20 P 1750 3 21.4 690 88800 84500 79500 4 BA 17° 71⁄2 M 1750 3 8.3 500 84000 77500 70200 64500 53600 4 BA 21° 10 N 1750 3 11.2 500 94500 88000 81500 73700 63600 4 BA 26.5° 15 O 1750 3 16.2 500 107000 100500 93500 85500 6 BA 22° 20 P 1750 3 22.4 546 117000 112000 107500 103000 97500 2810 6 BA 25° 25 Q 1750 3 27.7 546 117000 112000 107000 2907 1453 1890 1928 2210 2238 2260 2325 2345 2540 2560 2607 Performance certified is for Installation Type A: Free Inlet, Free Outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes transmission losses. Performance ratings do not include the effects of appurtenances (accessories). *For optional swing-out design weight, contact factory. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. CFM Limitations for Damper Lids Operation Series 69 CFM Minimum ① Maximum ➁ 12 1110 2725 14 1490 3670 ① Minimum CFM to open lids 16 1930 4750 18 2425 5975 20 2980 7335 24 4255 10475 28 5760 14175 Fan Size 32 36 7490 9445 18435 23250 40 11630 28630 44 14040 34560 48 16680 41055 54 21255 52315 60 26170 64410 66 30885 76025 72 84 36755 50030 90480 123150 ➁ Maximum CFM to prevent lid damage Bulletin A-157-K 13 www.hartzellfan.com 1 (800) 336-3267 Upblast (Belt Drive) Smoke Ventilator Features: • Designed for continuous operation at 500°F exhaust air temperature, with ambient air drawn through belt tube. • Size 18" - 60"... performance from 3220 CFM to 64,035 CFM • • • • Series 69H • Hartzell Fan, Inc., certifies that the Series 69H Upblast (Belt Drive) Smoke Ventilator shown hereon is licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Sound performance data is available upon request. Please contact the factory and ask for Engineering Publication #SD-159. • • Hartzell Fan, Inc. originally pioneered the development of the first powered smoke ventilator. Today, the Hartzell Series 69H Upblast Smoke Ventilator meets or exceeds rigid I.R.I. (Industrial Risk Insurers) Guidelines for Heat and Smoke Venting, No. IM.2.1.4 (supersedes Guideline No. p.2.6). An increasing number of insurance companies, local code bodies, and business and building owners are requiring these designated purpose ventilators to be installed, both in existing buildings and new structures. The advantages of a properly designed powered smoke ventilator approach to the effective removal of hot gases and smoke include: – the provision of early access into the building by firefighters. – reduce burden on the sprinkler system. – reduced risk of personal injury and property loss. Installing roof mounted gravity vents alone may be inadequate. Variables such as inside and outside air temperature, wind velocity and location of sprinklers can seriously affect the performance of gravity vents. The Hartzell Series 69H Upblast Smoke Ventilator is pre-engineered and designed to be used as a high temperature powered roof ventilator. It is self-contained, ready to install, wire, and put into service. Moreover, the Series 69H is a multi-use product. It is designed to be used on a daily basis as a power roof ventilator (special independent electrical connections may be required), and as a gravity type roof ventilator in the event of a power failure. Other specific features and advantages of the Hartzell Series 69H follow. • • • • • at free air. Heavy gauge, all ferrous steel construction – includes Hartzell's tested and proven belt drive duct fan design with stack cap and curb panel for a complete vertical discharge roof ventilator. Stack cap lids open automatically when the unit is operating, close weather tight when the fan stops. On the inlet side of the smoke vent, a curved inlet orifice increases the efficiency and the performance of the ventilator. The curb panel provides a convenient method of curb mounting the smoke ventilator. The heavy gauge steel construction ensures the unit's ability to withstand high temperatures and provides a durable and rugged unit. Welded steel propeller – three (3) bladed design with split taper bushing for easy removal from shaft. Reinforcements at the blade roots ensure stability and high stress characteristics. The welded steel propeller offers similar efficiency to the Hartzell cast aluminum lo-noise type propeller. Open end, drip proof motors with 1.15 service factor. TEFC and other motor enclosures are available upon request. Combination motor cover and belt guard – this standard feature provides weather protection and guards drive assembly. Cover is vented and removable. Belt drive arrangement – motor is mounted exterior to the fan housing. Belts, bearings, pulleys and shaft are enclosed and protected from the air stream. The drive assembly is located on the negative side of the propeller; fan design provides for the draft of ambient air from outside the ventilator in and over the belts and bearings. Belts – are heat resistant per I.R.I. standards. Drives feature two (2) belts minimum. Bearings – regreasable roller bearing type, supplied with high temperature grease, designed for minimum four hours at 500°F. Copper bearing lubrication tubes are extended from the bearings through the belt tube to the exterior of the fan housing, allowing ease of maintenance. Heat slinger – reduces heat conduction from the propeller to the shaft and helps draw air through the belt and bearing tube. Heat sinks – Aluminum plates dissipate radiant heat between motor and duct housing, disconnect switch and mounting bracket, and bearings and bearing base. Fusible link – spring operated, positive lid opener. When the temperature through the smoke vent exceeds 165°F, the fusible link allows the spring operated lid opener to lock the stack cap lids in the upright, open position. Provides gravity ventilation in case electricity to the power ventilator is interrupted. Disconnect switch – non-fused, rain tight, NEMA 3R enclosure mounted on the curb panel and wired to the fan motor provides safety during maintenance. Safety coating – standard finish is high temperature black enamel coating. Accessories • Coatings – special coatings for corrosion resistance are available upon request. • Pre-fabricated roof curb – 18 gauge galvanized construction • features full metal air stream liner. Available for flat, slope, or peaked roofs. Available in 8" or 12" height. Guard – inlet guard is constructed of expanded metal and woven wire mesh. Outlet guard is spiral, ring type. (Can also be used as a bird screen.) Bulletin A-157-K 14 www.hartzellfan.com 1 (800) 336-3267 Dimensions G INSIDE M L GA. AIRFLOW GA. E HEAT DEFLECTOR SHIELD STANDARD H FUSIBLE LINK STANDARD HEAT SLINGER STANDARD N HEAT SINK (BRG. BLOCK) STANDARD MOTOR COVER STANDARD J GA. LIFTING LUGS STANDARD K F GA. A B I.D. OF DUCT FAN C D B.C. SQ. INSIDE Principal Dimensions (Inches) H J K L M N MOTOR FRAMES MAX. 24 515/16 12 GA 12 GA 20 GA 26 GA 25 213T 30 5913/16 10 GA 12 GA 20 GA 26 GA 31 215T 36 5 16 63 / 10 GA 12 GA 20 GA 26 GA 34 215T 44 695/16 10 GA 12 GA 20 GA 26 GA 34 215T 23/4 50 781/16 10 GA 12 GA 20 GA 26 GA 42 215T 411⁄8 33/4 56 915/8 10 GA 12 GA 16 GA 20 GA 42 215T 57 / 1 4 64 / 41 ⁄8 3 4 3/ 62 7 8 91 / 10 GA 12 GA 16 GA 20 GA 42 254T 635/8 701/4 411⁄8 33/4 68 923/8 10 GA 12 GA 14 GA 20 GA 42 254T FAN SIZE A B C D E 18 187/8 215/8 205/8 28 221⁄16 2 24 247/8 291/8 267/8 36 229⁄16 23/4 30 30 / 1 8 35 / 33 42 22 ⁄16 3 4 2/ 36 37 413/8 39 48 289⁄16 23/4 42 427/8 471/4 45 54 289⁄16 48 491/8 531/2 515/8 581/4 54 55 / 60 / 60 613/8 665/8 78 3 8 5 8 5 8 9 1 F G Note: Specifications and dimensions are subject to change. Certified prints are available. Bulletin A-157-K 15 www.hartzellfan.com 1 (800) 336-3267 Performance Rating Table – Series 69H Size Number of Blades 3 18" 24" 30" 36" 42" 48" 54" 60" 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Blade HP Code RPM Code Peak Fan BHP S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S S / 3/4 1 11/2 1/2 3/4 1 11/2 2 3 1 11/2 2 3 5 1 11/2 2 3 5 71/2 11/2 2 3 5 71/2 10 2 3 5 71/2 10 3 5 71/2 10 15 5 71/2 10 15 F G H I F G H I J K H I J K L H I J K L M I J K L M N J K L M N K L M N O L M N O 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 0.50 0.75 1.10 1.64 0.49 0.75 1.10 1.65 2.20 3.29 1.09 1.66 2.19 3.31 5.51 1.37 1.79 2.20 3.28 5.49 7.30 1.41 2.35 3.31 5.46 8.22 9.59 2.60 3.31 5.46 8.23 10.47 3.31 5.56 8.24 10.91 12.42 5.45 8.37 10.82 14.70 Motor 1 2 Motor CFM @ Static Pressure Fan RPM Free Air 1730 1980 2250 2575 950 1095 1245 1425 1570 1795 830 1020 1120 1285 1525 720 830 910 1040 1235 1360 555 645 740 875 1005 1060 550 630 745 855 930 490 600 685 755 790 520 600 655 730 3220 3685 4190 4795 5230 6030 6855 7845 8645 9880 7830 9625 10570 12125 14390 12300 14180 15545 17765 21100 23235 16490 19155 21975 25980 29845 31475 24205 27730 32790 37630 40930 32400 39670 45290 49920 52235 45615 52635 57460 64035 / 2925 3425 3960 4595 1 8" 5285 6200 7275 8125 9430 6705 8730 9755 11420 13790 10235 12335 13835 16230 19775 22025 13650 16725 19860 24180 28255 29965 20485 24420 29930 35080 38570 27960 36005 42000 46910 49330 42320 50015 55230 62250 / 2635 3175 3735 4395 2905 3515 4200 2490 3265 4010 5525 6705 7610 8975 6015 7075 8525 6160 8050 7715 8885 10690 13195 7670 9875 12565 8705 11885 10260 12235 14900 18595 20915 13205 17490 19915 16115 18870 14245 17750 22415 26725 28530 15130 20645 25170 27055 18555 23650 25580 24395 30495 34355 19045 27860 32150 1 4" 21195 27315 32765 36415 23235 32425 38940 44130 46685 37000 46025 51820 59320 / 3 8" 28445 35690 41295 43990 31660 41130 47395 55845 / 1 2" 32150 38285 41135 36490 43230 51705 Performance certified is for installation Type A: free inlet, free outlet. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Performance ratings do not include the effects of appurtenances (accessories). Power rating (BHP) includes transmission losses. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code Explanation and example. Bulletin A-157-K 16 www.hartzellfan.com 1 (800) 336-3267 Hooded Roof Ventilator low-speed motors as in direct drive operations. Since the drive assembly is in the airstream, Series 16 ventilators are designed for clean air operation. Sizes 24" through 84", performance from 4,080 to 131,000 CFM at free air on intake; from 3,700 to 116,500 CFM at free air on exhaust. Also available as a Series 19I, 19E, or 19F, with motor out of the airstream. See drawing on next page. SERIES 17 (Direct Drive) and 17B (Belted) Truly reversible airfoil fans offer 100% air delivery for both intake and exhaust flows. Ratings vary slightly due to the difference in pressure drops in the intake and exhaust modes. This unit is ideal for applications where varying conditions call for intake (supply air) for some operations, and exhaust flow for others. Series 17 ventilators utilize the Hartzell reversible ring fan incorporating two curved orifice rings welded back-to-back with a reversible airfoil section propeller to provide efficient performance when operating in either direction. Sizes 18" through 72"… performance from 3,220 to 96,700 CFM at free air on intake; from 2,970 to 88,200 CFM at free air on exhaust. Series 15 (Direct Drive) Features: • Construction – ventilator hood and base are galvannealed “G” Duty Shown The hooded roof ventilator design provides complete protection from the elements for either exhaust or supply ventilation. The unit’s large hood surface reduces the air velocities through the ventilator. This feature minimizes pressure drop through the hood and eliminates the entrainment of rain into supply units. The fan assembly is placed in the upper section of the base, blades facing down, with the motor, drives, etc. located above the fan assembly, for ease of maintenance. The Hartzell hooded roof ventilators are designed with basic function in mind; they facilitate mounting of optional items. Hartzell has designed the Series 15 and 16 so that permanent or disposable filters may be added to the hood as an accessory item. Please refer to the separate rating table for filtered performance, beginning on page 23. NOTE: This catalog incorporates merely a representative group of Hartzell blades that are available. Many other adjustable blades and blade angles can be furnished. Contact your Hartzell representative for additional information and assistance. SERIES 15I (Intake) and 15E (Exhaust) – Direct Drive • • • • An efficient, high performance ventilator. Best suited for applications where the unit is in a difficult location for servicing. Sizes 18" through 72", performance from 2,350 to 90,300 CFM at free air on intake; from 2,050 to 78,500 CFM at free air on exhaust. SERIES 16I (Intake) and 16E (Exhaust) – Belted steel, painted with an industrial air dry enamel coating to provide maximum protection from the elements. Aluminum construction is also available for “H” Duty only. The fan frame is painted mild steel. The hood is hinged on units through size 36". This allows for the hood to be rotated to the side or removed for access to the fan assembly. Sizes 42" through 84" feature split hoods which are removable for access to the fan. These larger sizes are available with Hartzell’s unique slide-rail access package to allow easy separation of the hood halves for inspection and maintenance (see page 22). Standard construction on these units accommodates a 60 mph maximum wind load. Higher wind load construction features are available as an option. All hoods, size 36" and larger, are shipped separately from the base and are to be mounted in the field. Lifting eyes and hardware required for securing the hood to the base are furnished as standard. Motor Mount – “G” (General Industrial) Duty construction features an adjustable steel motor base and tubular steel frame, which are over-sized to provide structurally rugged construction. “G” Duty is available as Series 15I, 15E, 15F, 16I, 16E, and 16F in sizes 18" to 48" and will be limited by HP and RPM on certain sizes. Please reference the performance rating tables, the shaded models are those models offered as “G” Duty. “H” (Heavy Industrial) Duty construction features solid rolled rod supports, welded to the fan panel and motor mounts to provide support for the motor. The steel motor base and solid steel support rods are oversized to provide structurally rugged construction. “H” Duty is available in all sizes and models. Access Door – standard on all units. Motors – totally enclosed air over, foot mounted, T-frame motors are standard. Special motors are available upon request. See Motor Frame Size and Installation Weight Table for maximum motor frame sizes. Belted units, Series 16, are standard with adjustable motor slides for belt tightening. Propellers – cast aluminum airfoil type. Several configurations are available to accommodate maximum flow for a given size and horsepower configuration. Typically, Hartzell 2, 3, 4 and 6 blade assemblies are used. They include the Hartzell Types N, P, L, W, A, AW and BA designs for standard flow. The Type R and Type AR blades are used for reversible type applications. Some designs are fixed pitch; others are adjustable pitch. Particularly suited for applications where noise is a factor. The belted arrangement prevents the necessity of using costly, Bulletin A-157-K 17 www.hartzellfan.com 1 (800) 336-3267 Dimensions 4 3/8 E D J 4 3/8 LIFTING LUG FOR SQUARE OUTSIDE LIFTING LUG FOR LIFTING HOOD ONLY J LIFTING HOOD ONLY G AIRFLOW G E D SQUARE OUTSIDE AIRFLOW 2 1/4 (REF.) C (REF.) C NOTE: HOOD IN OPEN ROTATED POSITION OPTIONAL MOTOR LUBE TUBES F 2 1/4 OPTIONAL DISCONNECT SWITCH F OPTIONAL SHUTTER OPTIONAL BIRD SCREEN OPTIONAL MOTOR LUBE TUBES OPTIONAL BIRD SCREEN OPTIONAL DISCONNECT SWITCH OPTIONAL SHUTTER 13 1/2 CL 13 1/2 CL 6 6 3 1/2 3 1/2 4 4 A B OPTIONAL GUARD H A B HOLE IN GUSSET FOR LIFTING BASE ONLY SQUARE INSIDE 4 SQUARE INSIDE OPTIONAL GUARD H HOLE IN GUSSET SQUARE INSIDE FOR LIFTING BASE ONLY SQUARE INSIDE ACCESS DOOR ACCESS DOOR Sizes 18"– 36" Sizes 42"– 84" NOTE: The drawings show Series 15, direct drive, intake flow. Dimensions given below apply for Series 15, 16 and 17, direct or belt drive, intake, exhaust or reversible flow. Max Motor Frame Size Principal Dimensions – Series 15I, 15E, 15F, 16I, 16E, 16F, 17 and 17B H Fan Size A B C D E F G 18 24 30 36 42 48 54 60 72 84 22 ⁄4 281⁄4 351⁄4 421⁄4 481⁄4 541⁄4 601⁄4 661⁄4 811⁄4 941⁄4 30 ⁄4 361⁄4 431⁄4 501⁄4 561⁄4 621⁄4 681⁄4 741⁄4 931⁄4 1061⁄4 44 ⁄4 537⁄8 555⁄8 577⁄8 645⁄8 721⁄2 773⁄8 803⁄4 903⁄8 903⁄8 34 ⁄4 405⁄8 451⁄8 505⁄8 541⁄8 675⁄8 787⁄8 843⁄4 811⁄4 941⁄4 59 ⁄8 72 80 90 96 120 140 1505⁄8 184 200 31 ⁄2 381⁄8 381⁄8 381⁄8 435⁄8 461⁄4 463⁄4 473⁄4 505⁄8 505⁄8 12 ⁄4 153⁄4 171⁄2 193⁄4 21 261⁄4 305⁄8 33 393⁄4 393⁄4 1 1 1 1 5 1 J Galv 3 14 14 14 14 14 14 14 14 12 12 GA. GA. GA. GA. GA. GA. GA. GA. GA. GA. Alum Galv 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.090 0.125 0.125 18 18 18 18 18 18 18 18 16 16 GA. GA. GA. GA. GA. GA. GA. GA. GA. GA. Weight (less motor and options) Alum “G” Duty “H” Duty Galv Alum 0.063 0.063 0.063 0.063 0.063 0.063 0.063 0.063 0.090 0.090 56 145T 184T 213T 215T 254T ----- 56 145T 184T 215T 254T 254T 284T 286T 286T 286T 212 305 370 448 560 947 1203 1363 2339 3450 93 134 163 196 246 374 508 575 1950 2800 NOTE: Dimensions and specifications are subject to change. Certified prints are available. Maximum installation weight less motor and any optional equipment. Additional hood dimension shown for filtered units. Principal Dimensions – Series 19I, 19E, 19F FAN SIZE C F 24 633⁄8 477⁄8 30 671⁄8 495⁄8 36 743⁄8 545⁄8 42 915⁄8 705⁄8 48 967⁄8 705⁄8 54 1011⁄4 705⁄8 60 1035⁄8 705⁄8 72 111 ⁄4 72 84 3 1193⁄4 80 NOTE: HOOD IN OPEN ROTATED POSITION LIFTING LUG FOR LIFTING HOOD ONLY E D 4 3/8 G E D SQUARE OUTSIDE 4 3/8 SQUARE OUTSIDE LIFTING LUG FOR LIFTING HOOD ONLY J G MAX. 2 1/4 (REF.) C (REF.) C OPTIONAL MOTOR LUBE TUBES MAX. F OPTIONAL BIRD SCREEN MAX. 2 1/4 MAX. F MAX. BELT GUARD DISCONNECT SWITCH OPTIONAL SHUTTER BELT GUARD DISCONNECT SWITCH OPTIONAL SHUTTER 13 1/2 CL 13 1/2 CL 6 6 3 1/2 4 OPTIONAL GUARD OPTIONAL BIRD SCREEN OPTIONAL BEARING LUBE TUBES H 3 1/2 4 A B SQUARE INSIDE HOLE IN GUSSET FOR LIFTING BASE ONLY SQUARE INSIDE OPTIONAL GUARD ACCESS DOOR H A B HOLE IN GUSSET SQUARE INSIDE FOR LIFTING BASE ONLY SQUARE INSIDE ACCESS DOOR Sizes 42"– 84" Sizes 24"– 36" Bulletin A-157-K 18 www.hartzellfan.com 1 (800) 336-3267 Performance Rating Table – Series 15I or E – Direct Drive Hooded Ventilator Size 18" 24" 30" 36" 42" 48" 54" No. 0f Blade Blades Blade Angle 2 NA 8 Q 3 L 4 WB 4 WA Motor HP Code 1/4 D 1/4 D 1/3 E 1/3 E 1/2 F Motor Peak Fan RPM Code BHP 1725 3 .09 1725 3 .28 1725 3 .35 1725 3 .37 1725 3 .55 F G H I E F D I K L G I J F G H J K H I K J L H I F J K L 1725 1725 1750 1750 1140 1140 870 1750 1750 1725 1140 1160 1160 850 870 1750 1750 1750 1160 1160 1160 1160 1160 870 870 690 1160 1160 1160 3 3 3 3 4 4 5 3 3 3 4 4 4 5 5 3 3 3 4 4 4 4 4 5 5 6 4 4 4 .56 .86 1.07 1.50 .34 .52 .14 1.55 2.3 4.9 .74 1.25 1.75 .45 .65 1.08 2.00 2.82 1.12 1.40 2.43 2.40 3.83 1.03 1.64 .52 1.8 2.9 4.34 CFM @ 1/8" 1690 2940 3200 3520 4170 SP – INTAKE 1/4" 3/8" 6600 7325 8080 9040 5360 6540 4020 14050 13900 19700 9280 11425 13750 8350 10190 14270 17540 20350 15000 15200 18800 17910 22350 13530 16850 10730 22000 25850 27600 5810 6700 7670 8670 4750 5950 3070 13000 13200 19175 8250 10575 13000 7250 9050 12500 16200 19100 13500 14070 18000 17000 21450 12350 15150 9100 19500 23900 26450 4950 6000 7220 8275 4000 5150 12000 12550 18650 7120 9650 12190 10800 9450 11800 10950 18200 17750 5650 4200 8520 4980 11275 7600 10430 14670 17900 11750 12700 16800 16050 20600 11050 13800 6800 16900 21600 25300 3875 7900 13120 16800 9250 11100 15500 15100 19600 9350 11800 5450 12600 19450 24000 0" 2350 3235 3510 3845 4480 2480 2855 3220 3840 1900 1800 NB NC PA PB L PC L N PB PA PB L 4 3 6 2 2 2 2 6 6 3 4 3 4 3 2 2 6 W L PA ND NC NB NA PA PB L W L W L NB NA P /2 3/4 1 11/2 1/3 1/2 1/4 11/2 3 5 3/4 11/2 2 1/2 3/4 1 2 3 1 11/2 3 2 5 1 11/2 1/2 2 3 5 2 2 6 3 6 2 2 2 NB NA P L P NC NB NA 1 11/2 2 3 1 2 3 5 H I J K H J K L 850 850 850 850 690 1160 1160 1160 5 5 5 5 6 4 4 4 .85 1.25 1.87 2.7 .95 2.15 3.12 5.37 16800 19400 20400 23300 16400 25970 29400 34850 13700 16700 18750 21900 14250 23500 27100 33000 8900 13825 17050 20400 11750 21000 24550 30950 3600 6600 15100 18750 7700 17950 21650 28650 2 2 3 4 2 2 2 3 6 4 6 NA NA L AA NA NA NC L BA BA BA 2 1 5 71/2 5 2 3 71/2 10 3 5 J H L M L J K M N K L 870 690 870 1160 1160 870 870 870 870 690 690 5 6 5 4 4 5 5 5 5 6 6 2.18 1.12 4.45 8.48 5.04 2.13 3.13 8.40 11.00 3.35 5.50 25800 20700 31550 41800 40300 30600 34000 46500 48700 32000 38700 23300 17300 30000 40300 38150 27000 30900 44700 46500 28650 35900 20050 11600 28200 38700 35250 22800 27000 42800 44200 20700 31600 15750 20° 17.5° 14° 17.5° 1500 980 3375 2 2 6 6 3 6 3 2 6 6 6 3 1 1/2" 3350 5000 6770 7830 26400 37000 32350 17300 22300 40900 40800 21350 0" 2050 2950 3175 3430 3940 CFM @ SP – EXHAUST 1/8" 1/4" 3/8" 1/2" 1450 2610 2160 1760 2880 2420 1400 940 3170 3660 8300 17000 22300 5700 6400 7280 8175 4860 5810 3600 13100 13325 18900 8850 10860 13040 7950 9700 12400 15280 17700 13170 13600 16800 16280 19950 12300 14900 9700 19050 22400 25325 5050 5800 6910 7800 4300 5180 2600 12150 12700 18400 7900 10050 12300 6750 8600 10870 14170 16850 11870 12430 15800 15500 19100 11250 13700 8500 17000 20750 24200 7010 8970 12880 15850 10200 11150 14750 14620 18200 10000 12200 5550 14700 19100 23050 3500 12200 16800 5500 14400 18200 26000 14575 16900 18650 21250 14850 23100 25900 30800 11775 14750 17150 20000 2950 21000 23850 29050 7400 11950 15550 18500 10500 18670 21600 27100 3375 6200 11100 16900 7310 16000 19000 25000 22950 18300 28600 37070 35900 27000 30000 42000 42600 28400 33800 20330 15000 27200 35750 33650 23800 26900 40600 39900 23800 29900 17350 9400 25600 34250 31250 20200 23500 38900 36000 17200 23400 13150 6300 7200 3000 11100 15470 9200 14000 14000 18500 24500 35250 29000 39000 34000 4250 5100 6550 7340 3150 11150 12000 18000 6810 9150 11475 2850 3400 6130 6800 5550 6150 10050 8775 11250 10500 17550 17050 5400 4100 8000 4625 10575 3800 2950 11350 14750 7450 9750 13400 13650 17050 7500 9600 13500 8200 11200 12500 15600 11400 7600 17200 13600 22800 20400 23900 32600 28700 14600 18400 37000 30800 3200 9400 15000 5400 12800 15600 22400 21800 30800 25800 34800 26150 18100 Inst. Wt. # 228 228 236 236 234 327 331 335 340 329 331 334 405 434 448 400 442 453 400 405 478 483 520 483 520 531 531 590 520 531 483 643 679 702 632 643 679 702 643 1030 1066 1089 1066 1030 1151 1151 1345 1322 1345 1413 1493 1407 1413 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 19 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 15I or E – Direct Drive Hooded Ventilator (Cont’d.) Size 60" 72" No. of Blade Blades Blade Angle 3 L 2 BA 15° Motor HP Code Motor Peak Fan RPM Code BHP CFM @ SP – INTAKE 1/8" 1/4" 3/8" 0" 1/2" 0" CFM @ SP – EXHAUST 1/8" 1/4" 3/8" 1/2" Inst. Wt. # 15 O 870 5 14.10 63800 61900 59700 57600 55300 57600 55900 54300 52500 49500 1678 5 L 870 5 5.57 46250 42700 38750 34100 27800 40800 37600 33900 29750 22000 1567 4 BA 10° 3 K 690 6 3.30 36150 32500 28500 22150 4 BA 16.5° 5 L 690 6 5.45 45500 42400 39200 35500 27800 40900 38300 35000 30000 22800 32650 29500 25300 19700 1573 1567 4 BA 13° 71/2 M 870 5 8.35 51000 48650 46300 43500 40000 46400 44200 41500 38500 34800 1573 4 BA 16.5° 10 N 870 5 10.90 57500 55000 52700 50100 47500 51700 49500 47350 44900 41500 1653 6 BA 17.5° 15 O 870 5 16.30 64250 62800 61100 59300 57100 59000 57100 55250 53100 50700 1678 4 AA 14° 10 N 870 5 10.90 75500 71000 65000 59000 51500 66000 61500 56000 50500 45500 2157 4 AA 19° 15 O 870 5 16.80 90300 87000 82000 77000 69000 78500 74000 68500 62500 56500 2204 4 AA 14° 5 L 690 6 5.45 60400 53600 45500 36600 28700 52300 46200 39700 32500 2109 4 AA 19° 71/2 M 690 6 8.40 71900 66200 60000 49000 39000 62000 56700 48800 41300 35000 2137 4 AA 23° 10 N 690 6 11.20 79900 74500 68600 60000 43300 68700 63300 54300 44700 38900 2157 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Rating Table – Series 16I or E – Belted Hooded Roof Ventilator – Series 19I or E – Belt Drive Hooded Roof Ventilator Size 24" 30" 36" 42" 48" 54" 60" No. Of Blade Blades Blade Angle Motor HP Code Motor Peak Fan Fan RPM Code BHP RPM CFM @ SP – INTAKE 1/8" 1/4" 3/8" 3800 2000 /4 D 1750 3 .27 960 0" 4540 /3 E 1750 3 .36 1071 5070 4400 3400 /2 F 1750 3 .54 1220 5770 5200 4530 3100 /2 F 1750 3 .55 885 8600 7500 5850 2650 /4 G 1750 3 .82 1010 9760 8820 7750 5900 3390 L 1 H 1750 3 1.1 1150 11325 10450 9550 3 L 11/2 I 1750 3 1.62 1340 12800 3 L 2 J 1750 3 2.2 1480 3 L 1 /2 F 1750 3 .56 3 L 3 /4 G 1750 3 3 L 1 H 1750 3 L 11/2 I 3 L 2 3 L 3 3 L 1 3 L 1 3 L 1 3 L 1 3 L 3 3 1/2" 0" 4110 CFM @ SP – EXHAUST 1/8" 1/4" 3/8" 1/2" 3430 1700 900 Inst. Wt. # 333 4590 3980 2660 1520 5210 4700 4060 2500 8200 7100 5300 2600 9300 8440 7320 5400 3290 412 8500 5200 10775 9900 9100 7900 4700 416 12100 11290 10470 9500 12160 11400 10600 9900 8750 421 14200 13510 12950 12100 11500 13600 12950 12350 11630 10860 421 666 10250 8700 4700 9360 7830 4250 .82 764 11770 10400 8600 4100 10720 9430 7400 3950 3 1.10 837 12900 11680 10170 7200 4000 11750 10620 9100 5870 3900 493 1750 3 1.70 980 15100 14100 12920 11480 8640 13740 12800 11600 9920 7200 498 J 1750 3 2.09 1050 16180 15240 14170 12960 11350 14730 13830 12810 11500 9350 498 1 H 1750 3 1.1 595 15700 13580 4200 2670 14400 12320 8520 4100 2770 613 L 11/2 I 1750 3 1.65 703 18540 16580 14400 10550 5230 17800 15190 13130 9370 5150 618 3 L 2 J 1750 3 2.2 760 20200 18740 16780 13690 8750 18740 17100 15040 12100 8035 618 3 L 3 K 1750 3 3.3 930 24400 22000 20500 19050 16500 22700 21200 19500 17300 16800 655 3 L 5 L 1750 3 5.5 1100 28800 27100 26000 24500 21850 26600 25300 24000 22500 20800 3 L 1 H 1750 3 1.08 525 19100 16200 11100 17200 14800 8900 3 L 2 J 1750 3 2.20 660 23730 21680 19300 15100 8600 21550 19700 17150 11800 8200 1027 3 L 3 K 1750 3 3.00 740 26600 24750 22670 20340 15600 24070 22450 20470 17800 12800 1064 3 L 5 L 1750 3 5.17 895 32260 30700 29100 27300 25530 29250 27950 26400 24730 22400 1075 3 L 2 J 1750 3 2.02 497 26400 23400 15400 23900 20900 12900 3 L 3 K 1750 3 3.03 573 30300 27800 24750 14300 27650 25150 20200 12800 1333 3 L 5 L 1750 3 5.05 671 35550 33500 31100 28000 18000 32450 30450 27750 22600 15400 1344 3 L 71/2 M 1750 3 7.93 786 41650 39800 37850 35750 33200 37950 36300 34350 31800 27000 1380 4 AW 22° 5 L 1750 3 5.40 645 38900 36800 34500 31400 35150 33100 30000 4 AW 22° 71/2 M 1750 3 8.10 737 44400 42700 41800 38500 35600 40300 38500 36500 3 L 2 J 1750 3 2.29 437 31949 27952 21808 10464 30627 26862 18515 10335 6383 1485 3 L 3 K 1750 3 3.14 496 36262 32773 28757 16274 11331 34762 31549 27371 16058 11173 1522 3 L 5 L 1750 3 5.13 595 43500 40601 37600 34000 26260 41700 39100 36100 32298 21026 1533 4 AW 22° 71/2 M 1750 3 7.46 603 49532 46659 43823 40804 35407 47206 44721 42058 38853 1569 4 AW 22° 10 M 1750 3 10.00 665 54625 52003 49465 46812 43753 52060 49836 47420 44895 41429 1592 4 AW 22° 15 O 1750 3 14.85 761 62511 60204 57988 55734 53402 59575 57656 55574 53471 51198 1654 6 AW 25° 15 O 1750 3 14.52 683 62348 60771 59174 57583 55810 60299 58868 57319 55644 53548 1654 9980 1700 340 1660 338 408 485 489 666 1022 1296 1344 1380 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes drive losses. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 20 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 16I or E – Belted Hooded Roof Ventilator – Series 19I or E – Belt Drive Hooded Roof Ventilator (Cont’d.) Size 72" 84" No. of Blade Blades Blade Angle Motor HP Code Motor Peak Fan Fan RPM Code BHP RPM 0" CFM @ SP – INTAKE 1/8" 1/4" 3/8" 1/2" 0" CFM @ SP – EXHAUST 1/8" 1/4" 3/8" 1/2" Inst. Wt. # 4 AA 16° 71/2 M 1750 3 7.70 690 66600 61000 53700 51500 34000 58000 52200 44700 37000 2444 6 BA 13° 71/2 M 1750 3 8.00 531 61400 58000 54000 50000 46000 56500 53500 49700 46000 42300 2444 6 BA 17.5° 10 N 1750 3 11.20 531 70000 66700 63000 59000 55000 64000 61000 57500 54000 50000 2464 6 BA 24° 15 O 1750 3 16.80 531 84800 81600 77700 74000 70000 76000 73000 70000 66500 62500 2511 4 BA 16° 5 L 1750 3 5.83 455 76000 68500 60500 51500 67700 61500 54500 45000 3527 4 BA M 1750 3 8.10 546 83300 77000 70000 63300 55000 75000 69500 64000 57000 50000 3555 4 BA 21° 10 N 1750 3 11.20 500 97300 90500 83700 76000 66000 85500 80000 74000 66000 3575 6 BA 25° 15 O 1750 3 16.00 455 108000 103000 96200 90000 83000 95700 90700 85700 85700 3622 6 BA 25° 20 P 1750 3 21.40 500 118700 114300 108000 102500 96000 105300 100500 96000 90500 84500 3642 4 BT 22.2° 25 Q 1750 3 27.50 500 122800 118000 113000 108000 102000 109000 105200 100000 95500 90000 3705 6 BN 27° 25 Q 1750 3 27.13 455 131000 126500 122000 117000 112000 116500 113000 108000 103500 98000 3705 13.5° 71/2 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes drive losses. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Rating Table – Series 17 – Direct Drive Hooded Reversible Roof Ventilator Series 17B – Belted Hooded Reversible Roof Ventilator 18" 6 6 RB RA Motor HP Code I 11/2 1/4 D 24" 6 6 RB RA 1 11/2 H I 1750 1750 3 3 1.25 1.73 7510 8470 7110 8150 6 6 2 4 6 6 6 RA RB R R RA RB RA 1 11/2 2 1 2 3 1 H I J H J K H 1160 1160 1750 1140 1160 1160 870 4 4 3 4 4 4 5 1.20 1.60 1.92 1.09 2.20 3.40 1.20 9650 11350 16450 13150 14800 18250 11030 9000 10750 14770 11600 14050 17470 10050 6 6 4 4 4 4 6 R R AR AR AR AR AR 20° 23.5° 16° 22° 22° 3 11/2 5 71/2 11/2 3 2 K I L M I K J 870 690 1160 1160 870 870 690 5 6 4 4 5 5 6 3.50 1.75 5.30 7.70 1.65 3.10 2.30 22600 17850 30900 35700 18230 25200 21500 4 4 6 6 6 4 4 AR AR AR AR AR AR AR 17° 22° 25° 28° 22° 18° 22° 3 5 71/2 10 3 5 71/2 K L M N K L M 870 870 870 870 690 870 870 5 5 5 5 6 5 5 3.20 5.30 8.10 10.90 3.40 5.60 8.60 4 6 4 4 4 4 4 4 4 AR AR AR AR AR AR AR AR AR 25° 28° 16° 19° 16° 22.5° 25° 22° 26° 10 15 2 3 10 20 25 10 15 N O J K N P Q N O 870 870 690 690 870 870 870 690 690 5 5 6 6 5 5 5 6 6 11.65 17.20 2.35 3.45 10.60 21.70 27.70 10.90 16.00 Size 30" 36" 42" 48" 54" 60" 72" No. of Blade Blades Blade Angle Motor Peak Fan RPM Code BHP 3450 2 1.53 1750 3 .26 0" 5185 3220 CFM @ 1/8" 5050 2960 SP – INTAKE 1/4" 3/8" 4900 4750 2650 2170 1/2" 4610 1690 0" 4820 2970 6750 7770 6000 6980 6850 7750 6400 7400 CFM @ SP – EXHAUST 1/8" 1/4" 3/8" 1/2" 4700 4570 4430 4290 2710 2360 1975 1555 6240 7100 5860 6650 254 240 5440 6170 358 363 8400 7600 6650 9130 10150 9300 8400 10600 13030 11430 9500 14120 10000 8150 11700 13140 12350 11800 13770 16750 16000 15100 16750 9000 7880 6030 10260 8550 7900 7150 6150 10050 9350 8600 7600 12840 11600 10160 7900 10450 9070 6940 13000 12300 11790 11140 16150 15500 14750 13650 9370 8470 7300 5520 440 477 528 528 576 612 565 21350 16300 29600 34500 16750 23600 19900 20100 14950 28300 33300 15000 21900 18200 19050 17950 20900 16500 27000 25600 28700 32000 30700 32900 13250 10500 17200 20000 17550 23300 16250 13200 20100 19800 15300 27400 31800 15750 21800 18700 18900 14000 26300 30700 14200 20250 17100 25000 29600 12400 17400 15000 23700 28400 734 734 1154 1216 1095 1154 1154 27900 36000 43300 48100 30800 40600 49400 26000 34200 41800 46500 28900 38400 47400 23900 32200 40300 45100 27000 36400 45200 21800 30000 38600 43500 25000 34600 43500 19700 27800 37000 41700 22700 32000 40700 24300 31600 38600 42600 27300 36000 43800 22600 29700 37300 41200 25500 34100 41900 20600 27800 35800 39700 23300 32600 40300 18400 25500 34300 38200 55600 66100 29400 34200 62200 87400 96700 67700 78200 53700 64600 25900 31400 59600 85000 94000 64500 75200 51700 62900 23200 28700 57200 82600 91700 61400 72300 49900 61200 20000 25800 54800 80200 89300 58000 69000 47300 51000 49000 59500 60700 59100 26800 24500 22000 31700 29300 52400 58400 56200 77700 80500 78300 86600 88200 86000 54500 62500 59800 66000 71800 69000 47300 57600 22000 26800 54000 76200 83800 56600 66400 45900 55800 19000 24000 51800 73800 81600 53500 63500 43500 26000 33100 40000 44100 28800 37900 45600 6370 7430 Inst. Wt. # 17800 15700 11800 30000 37700 49500 71600 79400 50200 60300 1420 1482 1488 1568 1482 1657 1663 1743 1768 1595 1657 2304 2371 2434 2304 1929 CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes drive losses. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 21 www.hartzellfan.com 1 (800) 336-3267 Optional Filtered Hooded Ventilator The Hartzell Series 15F (direct drive) and 16F (belted) hooded roof ventilators are available with an optional filter rack, designed to accept standard sized filters. Permanent, washable filters and disposable filters are both available. This optional filter rack must be installed at the factory. As described on Page 18, the ventilator hood on sizes 18" through 36" is one piece. On size 42" through 84", the ventilator hood is in two pieces. Filters are accessible by removing retainer clips in the filter rack for ease of filter installation and maintenance. When you specify the filter option, other options and features are still available, including the slide rail package for split ventilator heads shown in the illustration above. On the pages that follow, actual filtered supply performance ratings are provided for both the Series 15F and 16F hooded ventilators. Features: • Sizes – Series 15F – Direct Drive – size 18" through 72" performance from 1,375 to 88,000 CFM at free air. • Series 16F – Belted and Series 19F – Belt Drive – size 24" through 84"… performance from 3,990 to 128,000 CFM at free air. • Construction and Dimensions – are identical to the standard Series 15F and 16F units. Please refer to Pages 17 and 18, “G” (General Industrial) Duty and “H” (Heavy Industrial) Duty construction available. Refer to Rating Tables on Pages 23 and 24. The filter rack adds an additional 21⁄4" to the overall vertical dimension of the ventilator hood, but does not increase the overall unit height. • Filters – permanent, washable filters are provided as standard and the performance ratings that follow are based on losses through permanent filters. Resistance through disposable filters tends to be higher. Please refer to the resistance curve for disposable filters on this page. Use of disposable filters will cause the fan performance to change. • Other Options and Accessories – are available. Please see Pages 33 and 34. Series 15F, Size 30", with permanent filters HOODED VENTILATOR RESISTANCE CURVES (VEL. VS. S.P.) 1 .900 .800 (1) DISPOSABLE FILTERS (2) PERMANENT FILTERS (3) DAMPER .700 .600 .500 (1) .400 (3) .300 (2) .250 Series 15F, Size 42", with permanent filters and optional slide rail package S.P. (IN. W.G.) .200 .150 .100 .090 .080 .070 .060 .050 .040 VELOCITY = HOOD NET SIZE FREE AREA .030 18 24 30 36 42 48 54 60 72 84 .025 .020 .015 13.9 24.8 29.4 32.2 34.2 62.5 91.0 105.6 148.4 213.5 CFM AREA (SQ. FT.) FILTER AREA DAMPER AREA 7.2 23.6 27.6 31.6 33.2 60.0 86.0 101.2 143.8 176.0 2.5 4.34 7.11 10.56 14.06 18.06 22.56 27.56 42.25 57.5 .010 1 1.5 2 2.5 3 4 5 6 7 8 9 1 1.5 2 2.5 3 VELOCITY (FPM X 100) Bulletin A-157-K 22 www.hartzellfan.com 1 (800) 336-3267 Performance Rating Table – Series 15F – Filtered Hooded Ventilator – Direct Drive Size 18" 24" 30" 36" 42" 48" 54" 60" 72" Blade Angle Motor Code D E E F D F G Motor RPM Code 1725 3 1725 3 1725 3 1725 3 1140 4 1725 3 1725 3 No. of Blades 8 3 4 4 4 2 2 Blade Q L WB WA WA NB NC 6 6 3 6 2 6 6 6 3 3 4 PA PB L PC N PB PA PB L L W 1 11/2 1/3 1/2 11/2 2 5 3/4 1 11/2 2 H I E F I J L G H I J 1750 1750 1140 1140 1750 1750 1750 1140 1160 1160 1160 3 3 4 4 3 3 3 4 4 4 4 2 6 6 6 4 3 4 2 2 6 2 6 3 6 2 2 N PA PA PB W L W NB NA P NA P L P NA NA /4 /2 11/2 2 5 1 11/2 2 3 5 11/2 2 3 1 5 2 D F I J L H I J K L I J K H L J 850 850 1160 1160 1160 870 870 1160 1160 1160 850 850 850 690 1160 870 2 4 4 4 2 2 2 3 6 4 2 4 4 6 4 4 4 4 4 NA AA AA AA NA NA NC L BA BA BA BA BA BA AA AA AA AA AA 1 11/2 3 71/2 5 2 3 71/2 10 3 5 71/2 10 15 10 15 5 71/2 10 H I K M L J K M N K L M N O N O L M N 690 690 870 1160 1160 870 870 870 870 690 870 870 870 870 870 870 690 690 690 HP 1/4 1/3 1/3 1/2 1/4 1/2 3/4 1 1 19° 19° 20° 17.5° 10° 15° 13° 16.5° 17.5° 14° 19° 14° 19° 23° Peak Fan BHP .28 .34 .37 .55 .16 .56 .79 0" 3175 3430 3730 4340 2790 6700 7130 1/8" 2870 3145 3430 4090 2410 5630 6475 1.13 1.50 .33 .52 1.6 2.1 4.0 .71 1.15 1.2 1.75 7870 8820 5230 6350 13525 13600 17800 9080 11025 11125 13360 5 5 4 4 4 5 5 4 4 4 5 5 5 6 4 5 .18 .48 1.40 2.42 3.85 1.03 1.64 1.8 2.92 4.6 1.25 1.82 2.68 1.0 5.37 2.19 6 6 5 4 4 5 5 5 5 6 5 5 5 5 5 5 6 6 6 1.12 1.63 3.26 8.48 5.04 2.13 3.15 8.30 11.00 3.31 5.57 8.40 10.90 16.30 11.00 16.80 5.50 8.40 11.20 CFM @ SP 1/4" 2400 2765 3115 3710 3/8" 1860 1660 1/2" 1490 1175 4770 5760 3100 7470 8450 4640 5770 12575 12925 17275 8100 10175 10300 12600 7030 8070 3860 4940 11550 12250 16800 6990 9300 9400 11790 6580 7580 6110 6990 10400 11575 16200 5520 8200 8300 10875 9100 10700 15600 4150 6520 8650 14700 18400 21700 13250 16350 19850 23250 25850 17450 19100 21850 15325 33800 25150 4200 7500 13600 17400 20900 12100 15150 17700 21425 24800 15225 17600 20450 13300 32000 22700 4350 12200 16200 20000 10800 13750 15400 19650 23600 12400 15950 19000 10725 29900 19400 2875 10750 15000 19000 8800 11650 12050 17825 22350 6300 14000 17400 7400 27700 15000 2050 8800 13200 17900 20150 23400 29500 41200 39500 29700 33000 45250 47200 35500 44900 49750 55900 63000 73200 88000 58700 69700 77300 16550 20800 27500 39000 36900 26200 29800 43500 45000 31900 41300 47500 53600 61400 68500 84000 52000 63800 72000 10800 17300 25200 37500 34200 22200 26000 41600 42500 28000 37500 45100 51300 59800 63000 79000 44000 57500 66000 22300 35800 31300 16700 21400 39900 38500 21500 32700 42200 48800 57800 57000 73300 35300 46600 54000 Net Inst. Weight # 4800 7700 14450 20900 3250 10800 15400 5400 25000 34000 28200 38000 30800 26100 38800 46100 55500 50000 65500 37500 42000 256 264 264 262 257 377 381 385 390 379 381 463 463 506 458 459 500 511 457 458 586 597 656 586 597 714 750 773 714 750 844 714 1216 1193 1157 1193 1216 1278 1508 1485 1508 1576 1656 1740 1740 1746 1826 1851 2443 2490 2395 2423 2443 Performance shown includes resistance through filters. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 23 www.hartzellfan.com 1 (800) 336-3267 Rating Table – Series 16F – Filtered Hooded Ventilator – Belted Series 19F – Filtered Hooded Ventilator – Belt Drive Size 24" 30" 36" 42" 48" 54" 60" 72" 84" Motor Motor Peak Fan HP Code RPM Code BHP Fan RPM L L L L L L L L L L L L L L L L L L L /4 /4 1/3 1/2 1/2 3/4 1 11/2 2 1/2 3/4 1 11/2 2 1 11/2 2 3 5 1 D D E F F G H I J F G H I J H I J K L H 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 1750 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 .18 .27 .36 .54 .55 .82 1.1 1.62 2.2 .56 .81 1.10 1.70 2.08 1.1 1.65 2.2 3.3 5.5 1.08 3 3 3 3 3 3 L L L L L L 2 3 5 2 3 5 J K L J K L 1750 1750 1750 1750 1750 1750 3 3 3 3 3 3 3 4 4 3 3 3 3 L AW AW L L L L 71/2 5 71/2 2 5 71/2 15 M L M J L M O 1750 1750 1750 1750 1750 1750 1750 4 4 4 4 4 4 4 AW AW AW AW AA AA AA 25° 25° 25° 25° 22° 16° 20° 3 71/2 10 15 5 71/2 10 K M N O L M N 6 6 6 4 4 4 4 BA BA BA BA BA BA BA 21.5° 25° 23.5° 16° 25° 17° 26.5° 15 20 25 5 10 71/2 15 4 6 4 6 BA BA BA BN 27° 28° 29° 27° 20 30 20 25 No. of Blades Blade 3 L 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Blade Angle 1 1 22° 22° 862 960 1071 1220 900 1030 1150 1340 1480 666 764 837 980 1050 595 725 815 930 1100 525 0" 3990 4420 4940 5610 8520 9710 11025 12460 15300 10050 11550 12630 14770 15820 14920 18220 20400 23200 27100 18700 1/8" 3100 3660 4270 5030 7450 8820 10175 11840 14800 8500 10200 11470 13800 14900 12600 16650 19100 21700 26000 16000 2.07 3.00 5.10 2.01 3.00 5.03 660 740 895 497 573 671 23250 26000 31500 25750 29650 34700 21200 24200 30000 23800 27150 32700 3 3 3 3 3 3 3 7.88 5.30 8.07 2.00 5.15 7.50 14.95 786 645 737 437 595 672 858 40650 38000 43400 30600 41500 46900 60000 1750 1750 1750 1750 1750 1750 1750 3 3 3 3 3 3 3 2.95 7.86 10.60 15.80 5.50 7.70 11.00 436 603 665 761 531 690 690 O P Q L N M O 1750 1750 1750 1750 1750 1750 1750 3 3 3 3 3 3 3 16.50 21.50 27.70 5.83 11.00 8.25 16.20 P R P Q 1750 1750 1750 1750 3 3 3 3 21.80 33.00 21.73 26.92 CFM @ SP 1/4" 1990 3170 4380 5750 7680 9300 11070 12700 4650 8450 9950 12670 13900 8740 14700 17700 20000 23500 10600 3/8" 1/2" 2900 2500 5710 8200 10250 11890 3330 4900 9330 10750 4100 6850 11200 12700 4100 11740 16090 17850 22900 4000 8300 10950 2020 7640 13650 17350 21400 18900 22200 28400 14800 23700 30250 14800 19750 26800 15200 24800 13800 26800 17000 38900 36000 41600 26700 38800 44500 58050 36950 33500 39700 21200 35750 41800 56000 34800 31800 36600 50400 55600 63600 60500 64800 74000 32800 48000 53500 61700 53500 59000 69000 26600 45200 51100 59800 38000 52000 62000 690 690 637 455 455 500 500 85000 93300 98000 74300 93800 84000 106300 80500 88700 95000 67000 87000 77700 100000 546 546 455 455 118000 135500 124500 128000 112000 130000 118400 124000 Net Inst. Weight # 37300 383 383 390 388 466 470 474 479 479 551 555 559 630 630 684 689 689 726 737 1149 1154 1191 1202 1459 1496 1507 1543 1507 1543 1658 1706 1741 1827 32000 38800 53900 24900 35200 51800 41600 48200 57400 32000 44400 55000 42000 52000 33000 41300 76500 85000 92500 59500 79500 70700 93500 70500 80000 89500 50700 70000 63500 85700 61500 54000 76000 2797 2800 2880 3877 3925 3905 3972 106000 125500 112500 119000 99300 121000 106000 114500 91300 115000 98000 109500 3992 4097 3992 4072 86500 1695 1742 1765 1737 2694 2730 2750 Performance shown includes resistance through filters. CFM shown is net flow at the inlet and includes static pressure loss through ventilator. Note: For aluminum construction – multiply weight by .75. Power rating (BHP) includes drive losses. “G” (General Industrial) Duty construction available for models with shaded performance. “H” (Heavy Industrial) Duty construction available for all models. Bold-type information provided in the Rating Table above is needed when preparing a model code. See page 2 for the complete Hartzell Model Code example and explanation. Bulletin A-157-K 24 www.hartzellfan.com 1 (800) 336-3267 Hoodjet Ventilator • Extended Lube Tubes – will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings). Hartzell Hoodjet Ventilators are available in three styles: (1) air intake; (2) air exhaust; (3) reversible…combination intake and exhaust. Direct Drive – Series 71J An efficient, high performance ventilator, best suited for applications where the unit is in a difficult location for servicing and maintenance. Sizes: 28" – 60" Performance from 5,480 to 36,500 CFM at free air intake; from 5,480 to 60,600 CFM at free air exhaust. Propellers: 28" – 60" 2-blade, Type N 28" – 60" 3-blade, Type L 28" – 44" 4-blade, Type W 28" – 44" 6-blade, Type P 48" – 60" 4-blade and 6-blade adjustable, Type A Series 71 J (Direct Drive) Series 73J (Belted) Series 75J (Reversible) Belted – Series 73J Features The Series 73J is close-coupled, belt driven, with the motor in the airstream. This ventilator utilizes Hartzell’s exclusive "L" propeller which is designed to provide high volume airflow at low tip speeds and relatively low noise levels. Drive shafts are ground and polished, keyed at both ends. Bearings are heavy duty, self-aligning, deep-row, radial ball type, shielded and mechanically sealed in cast iron or malleable housing; relubricable type for continuous service. Belts are oil, heat and static resistant type, over-sized for continuous duty. Sizes: 28" – 60" Performance from 5,870 to 40,550 CFM at free air on intake; from 5,870 to 51,000 CFM at free air exhaust. Propellers: 28" – 60" 3 blade lo-noise, Type L. • Construction – galvanized steel base and hood; painted steel orifice panel and fan frame. The hood is hinged to swing back for easy access to the fan assembly. The airflow splitter in the hood allows for the same high efficiency in either direction. The aerodynamically designed hood provides a compact, low profile. Hooded ventilators are also available in painted steel and aluminum construction. • Motors – belted units (Series 73J) feature close-coupled drive and totally enclosed air over motors. Direct drive units (Series 71J and 75J) feature totally enclosed air over motors. • Propellers – cast aluminum and airfoil type. Options and Accessories Reversible – Direct Drive – Series 75J • Shutters – automatic, motor, or manually operated shutters can be mounted in either the throat of the unit or below the roof line. • Access Door – hinged door with quick release latches for access to the interior of the hoodjet. • Bird Screen – half-inch square opening wire mesh, constructed of either galvanized steel or aluminum. • Disconnect Switch – NEMA watertight enclosure available as an option. An ideal unit for applications where varying conditions may call for intake during some periods and exhaust during others. The Series 75J ventilator utilizes the Hartzell reversible ring fan incorporating two-curved orifice rings welded back-to-back with a fully reversible airfoil section propeller to provide the same efficient performance when operating in either direction. Sizes: 28" – 60" Performance from 6,800 to 44,700 CFM at free air. Propellers: 28" – 60" 2-, 4-, and 6-blade reversible, Type R. BIRD SCREEN OPTIONAL INTAKE H G REVERSIBLE EXHAUST AIRFLOW AIRFLOW AIRFLOW AIRFLOW LATCH CHAIN AIRFLOW AIRFLOW F HINGE *D *D OR D1 * D OR D2 4 ROOF ROOF SHUTTERS SHUTTERS SHUTTERS STANDARD SHUTTER LOCATION LOCATION (TYPICAL) ANCHOR STRAPS (4) FURNISHED ON 36 INCH SIZE AND LARGER TYPE "A" (CURB BASE) 4 C MAXIMUM CURB B OPTIONAL THROAT MOUNTED SHUTTER LOCATION. INCLUDES ACCESS DOOR INSIDE VENT CURB TYPICAL Principal Dimensions – Series 71J, 73J and 75J NOM. SIZE B C D D1 D2 F G H 28 32 36 44 48 54 60 413/4 441/2 503/4 601/4 65 731/4 791/4 331/4 361/4 421/4 513/4 561/2 641/2 701/2 181/2 181/2 181/2 213/4 231/2 253/8 29 28 28 28 28 28 28 28 34 34 34 34 34 34 37 207/8 231/2 263/4 325/8 351/2 40 455/8 66 72 84 103 112 126 143 34 37 43 521/2 571/2 651/2 713/4 D MINIMUM MATERIAL GAUGE HEAD BASE 20 20 20 18 18 18 18 14 14 14 14 14 14 14 Specifications and dimensions are subject to change. Certified prints are available. 5 12 TYPE "C", PEAK BASE NOTES: 1. *“D” dimension is for all ventilators without shutters in throat, and for exhaust vents with throat mounted auto or manual shutters. 2. *“D1” dimension is for intake or exhaust vents using motor operated shutters. 3. *“D2” dimension is for reversible vents using motor operated shutters. 4. Stutters are optional, and must be specified on order along with locations. 5. With “B” or “C” type bases, the “G” dimension may be lengthwise (L) – perpendicular to slope or slopewise (S) parallel to slope. If slope exceeds 6 inches per foot, the “G” dimension must be perpendicular (“L” type) to the slope when using “B” base. 6. When using either “B” or “C” base, the direction of the “G” dimension must be specified as “BS”, “BL”, “CS” or “CL”. 7. Lube tubes extended to the outside of the base is optional. Bulletin A-157-K 25 CUSTOMER TO SUPPLY SLOPE IN INCHES PER FOOT TYPE "B", SLOPE BASE 5 M M = SLOPE 12 www.hartzellfan.com 1 (800) 336-3267 Series 71J - Direct Drive Hoodjet Ventilator Rating Table SIZE 28" 32" 36" 44" 48" 54" 60" Series 73J - Belted Hoodjet Ventilator Ventilator Rating Table CFM @ SP 1/8" 1/4" NO. OF TYPE BLADES HP MAX. BHP RPM 0" ND3 NF3 NG3 NH3 PI3 PJ3 ND4 LG4 WH4 WF5 NH3 NJ3 NF4 PH4 LI4 WJ4 LF5 WH5 NH3 NJ3 NK3 NF4 NH4 LJ4 WL4 NF5 LH5 WI5 NH4 NJ4 NK4 PL4 N5 NI5 PJ5 OK5 WL5 NJ4 NK4 NL4 NJ5 AK5 LL5 AJ6 NK4 NL4 NM4 NK5 AL5 AM5 AK6 AL6 NK4 NL4 NM4 NN4 NK5 AL5 AM5 AN5 LO5 AK6 AL6 LM6 ⁄4 ⁄2 3 ⁄4 1 11⁄2 2 1 ⁄4 3 ⁄4 1 1 ⁄2 1 2 1 ⁄2 1 11⁄2 2 1 ⁄2 1 1 2 3 1 ⁄2 1 2 5 1 ⁄2 1 11⁄2 1 2 3 5 1 11⁄2 2 3 5 2 3 5 2 3 5 2 3 5 71⁄2 3 5 71⁄2 3 5 3 5 71⁄2 10 3 5 71⁄2 10 15 3 5 71⁄2 0.28 0.45 0.71 0.99 1.50 2.00 0.27 0.68 1.10 0.43 1.00 2.00 0.55 0.83 1.50 2.20 0.60 0.93 1.10 2.00 2.80 0.54 1.10 2.30 3.80 0.43 1.00 1.60 0.97 2.20 3.50 5.10 0.98 1.50 2.10 3.10 5.00 2.20 3.10 5.40 2.20 3.30 4.30 2.20 2.90 5.00 7.10 3.20 5.50 8.20 3.35 5.50 3.80 5.20 7.40 9.90 3.00 5.60 8.40 10.90 13.50 3.30 5.50 6.80 1725 1725 1725 1750 1750 1750 1140 1140 1160 850 1750 1750 1140 1160 1160 1160 850 870 1750 1750 1750 1140 1160 1160 1160 850 870 870 1160 1160 1160 1160 870 870 870 870 870 1160 1160 1160 870 870 870 690 1160 1160 1160 870 870 870 690 690 1160 1160 1160 1160 870 870 870 870 870 690 690 690 5480 6630 8230 8740 9580 11100 5690 7710 9370 6870 10590 13620 8850 9520 11580 13730 8500 10300 12700 15650 18100 10180 13460 16530 20300 9790 12510 15230 16640 21880 25600 28500 16830 19300 21100 24000 29450 24450 27530 32800 24450 28570 30100 25230 30500 38200 42500 31900 34400 41050 30100 36200 36000 42650 48500 54000 36500 45650 48600 54400 60600 34370 43050 48100 2 2 2 2 6 6 2 3 4 4 2 2 2 6 3 4 3 4 2 2 2 2 2 3 4 2 3 4 2 2 2 6 2 2 6 3 4 2 2 2 2 4 3 4 2 2 2 2 4 4 4 6 2 2 2 2 2 2 4 4 3 4 4 3 1 1 4160 5700 7430 8000 9140 10670 4400 7080 8760 6010 9590 12800 7460 8630 10750 13100 7400 9430 11160 14500 17180 8220 12080 15750 19460 7680 11450 14100 14350 19800 23950 27450 13840 17100 19600 22700 27930 22230 25400 31000 21850 26650 28550 22650 27650 35750 40200 28800 31500 38800 26800 33100 32250 39700 45600 50400 32200 42000 46350 52200 58750 30900 40250 45700 SIZE 2450 4600 6450 7170 8680 10180 28" 32" 6340 8120 36" 8390 11870 7450 10050 12370 5000 44" 48" 9200 13270 16200 5400 10500 14870 18540 10220 12650 11270 17600 22200 26300 9600 14450 17900 21300 26400 19900 23050 29050 18700 24350 26900 19300 24450 33200 37750 25300 25750 35700 18400 26700 28300 36000 42650 46000 27250 38280 13850 19950 56600 26930 37270 43200 54" 60" CFM @ SP 1/8" 1/4" NO. OF TYPE BLADES HP MAX. BHP RPM 0" LE3 LF3 LG3 LF3 LG3 LH3 LI3 LJ3 LF3 LG3 LH3 LI3 LJ3 LI3 LJ3 LK3 LL3 LJ3 LK3 LL3 LJ3 LK3 LL3 LM3 LK3 LL3 LM3 LN3 ⁄3 ⁄2 3 ⁄4 1 ⁄2 3 ⁄4 1 11⁄2 2 1 ⁄2 3 ⁄4 1 11⁄2 2 11⁄2 2 3 5 2 3 5 2 3 5 71⁄2 3 5 71⁄2 10 0.36 0.54 0.74 0.53 0.76 1.0 1.5 1.9 0.57 0.81 1.1 1.7 2.0 1.5 1.9 3.0 4.8 2.0 2.9 4.9 2.0 3.0 4.8 7.5 3.0 5.0 7.3 9.7 883 1035 1165 825 945 1045 1190 1305 666 764 837 980 1050 680 738 853 1010 660 740 895 497 573 671 786 496 595 672 747 5870 6870 7750 8100 9270 10280 11690 12820 9520 10900 11930 14000 15000 18800 20400 23500 27850 22730 25400 30700 25150 28970 33950 39700 33800 40550 45750 51000 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 5010 6160 7130 7050 8360 9460 10980 12170 8000 9600 10820 13030 14090 17000 18950 22220 26900 20750 23650 29350 22170 26500 31900 37970 30500 37900 43400 49000 2800 5200 6430 4500 7200 8510 10190 11490 4470 7640 9300 11880 13100 14850 16930 20630 25600 18250 21650 27800 14000 22600 29500 36100 26400 34900 40700 46700 NOTE: All belted fan ratings include drive losses. Series 75J - Reversible Hoodjet Ventilator Rating Table SIZE 28" 36" 44" 48" 54" 60" NO. OF TYPE BLADES RF3 RH3 RE4 RJ3 RH4 RK4 RF4 RL4 RJ5 RH6 RK4 RK4 RM4 RN4 RL5 2 4 4 2 4 6 2 6 6 6 2 2 2 2 2 CFM @ SP 1/8" 1/4" HP MAX. BHP RPM 0" ⁄2 1 1 ⁄3 2 1 3 1 ⁄2 6 2 1 3 3 71⁄2 10 5 0.55 1.1 0.32 1.9 1.1 3.2 0.6 5.6 2.3 1.2 3.4 2.9 6.5 9.4 3.9 1725 1750 1140 1750 1160 1160 1140 1160 870 690 1160 1160 1160 1160 870 6800 8450 5570 14480 11870 18000 9600 26400 19800 15400 25670 29200 37000 44700 33550 1 5750 7750 4560 13050 10580 16300 7570 25300 18150 13430 23200 26800 34300 42100 30050 4600 7130 2790 11730 9200 15650 4400 24000 16470 11770 20700 24000 31500 39500 26000 NOTE: Shaded ratings not recommended for intake use. When specifying, be sure to include SERIES, SIZE, and TYPE. Model Code Example: 71J-36-LJ4 Series: 71J Size: 36" Type: LJ4 Bulletin A-157-K 26 www.hartzellfan.com 1 (800) 336-3267 Recirculating Roof Ventilator The Series 26 unit, equipped with reversible airfoil propeller, provides exhaust ventilation in warm weather and recirculation of warm ceiling air down to floor level in cool weather. Standard Features • Sizes – 24", 30", 36", 42", 48", 54" and 60" Performance from 7,500 to 54,761 CFM at free air. • Construction – a removable galvannealed windband on sizes through 54". On • • • • • • Series 26 • 60" size, material shall be constructed of painted mild steel. Dampers open automatically when unit is used for exhaust, closes weather-tight when unit is used for recirculation. During exhaust operation, discharge air effectively prevents the entry of rain. The recirc section is constructed of 12 ga. hot rolled steel, painted. Aluminum recirc ventilators are available; entire unit is constructed of aluminum with stainless steel hardware. Propellers – one-piece cast aluminum reversible airfoil propeller in a direct drive reversible panel fan in the recirc section of the housing. Sizes – 24" to 42" – 6 blade – Type R Sizes – 48" to 60" – 6-blade adjustable – Type AAR Fan Assembly – consists of two curved orifices welded together face-to-face. The same efficient performance exists for either exhaust or recirc operation. Hinged Access Door – equipped with two flush head, button-type latches providing easy access to motor, shutters and controls. Shutters – two automatic shutters constructed of aluminum are built into each unit located in the lower section of the housing. Motors – totally enclosed, air over fan duty motors are standard. Special motors are available upon request. Lifting lugs – welded at two opposite (diagonal) inside corners of the plenum section furnished as standard for ease in handling this section during installation. Unit Installation – lower recirc section (containing fan and shutters, factory installed) and upper ventilation housing are shipped separately for assembly at job site. Recirc section drops through the roof for ease of installation. Accessories • Coatings – special coatings are available upon request. • Diffusers – 2-and 4-way diffusers are available for all sizes. • Birdscreen – for installation in throat section. Fabricated of 1/2" wire mesh. • Controls – for reversing the motor are the only ones required for unit operation. • • Reversal may be manual or automatic. Units available with or without controls. Units ordered without controls provided less damper actuators. Adapter Bases – slope or peak adapter bases available as an option. Specify slope per foot. Prefabricated Curbs – available for flat, slope or peak roof mounting. Curbs are designed for metal, concrete or wood roof decks that are not surface insulated. Available either 8" or 12" high of galvanized or aluminum construction. See Page 34. Bulletin A-157-K 27 www.hartzellfan.com 1 (800) 336-3267 Principal Dimensions (Inches) – Series 26 FAN SIZE A B C D E G H J L M 24 243⁄16 281⁄2 54 36 231⁄2 351⁄4 13 167⁄8 23⁄4 13H x 25W 30 303⁄16 351⁄2 581⁄2 42 231⁄2 411⁄4 16 183⁄8 23⁄4 16H x 32W 36 363⁄16 421⁄2 623⁄4 48 291⁄2 471⁄4 19 195⁄8 23⁄4 19H x 39W 42 42 ⁄16 48 ⁄2 67 ⁄4 54 41 ⁄2 53 ⁄4 22 21 ⁄8 3 2 ⁄4 22H x 45W 48 483⁄16 541⁄2 701⁄4 641⁄4 421⁄2 631⁄2 25 211⁄8 33⁄4 25H x 51W 54 543⁄16 601⁄2 733⁄4 701⁄4 421⁄2 691⁄2 28 215⁄8 33⁄4 28H x 57W 60 603⁄16 661⁄2 881⁄8 793⁄4 405⁄8 79 31 33 4 31H x 63W 3 1 1 1 1 1 AIRFLOW FLANGE G O.D. DROP THRU SECTION LIDS PREFAB. CURB 24 24* ACCESS OPENING C OPENING M SHUTTER HxW OPENING H ACCESS D SQ. I.D. ACCESS DOOR J I.D. A O.D. B REVERSIBLE PANEL FAN Rating Table – Series 26 Size 24" 30" 36" 42" 48" 54" 60" No. of Blades Blade Blade Angle HP Code RPM Code Peak Fan BHP 0" 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 RB RA RA RB RA RB R AR AR AR AR AR AR AR AR AR AR AR AR AR 25° 29° 25° 29° 24° 28° 29° 21.5° 27° 22° 28° 20° 25° 28° 22.5° 26.5° 28° 16.5° 20.5° 23° 1 11⁄2 1 11⁄2 2 3 3 3 5 3 5 5 71⁄2 10 5 71⁄2 10 5 71⁄2 10 H I H I J K K K L K L L M N L M N L M N 1750 1750 1160 1160 1160 1160 870 870 870 690 690 870 870 870 690 690 690 870 870 870 3 3 4 4 4 4 5 5 5 6 6 5 5 5 6 6 6 5 5 5 1.13 1.61 1.09 1.57 2.33 3.29 3.35 3.40 5.45 3.35 5.62 5.10 7.90 10.55 5.48 7.40 8.40 5.48 7.94 10.5 7530 8500 9650 10650 14700 15550 22100 26250 32100 30500 37700 34900 42800 47550 42911 48565 51800 39412 47556 54761 Motor Motor CFM @ STATIC PRESSURE 1/8" 7100 8150 8970 10000 13950 14600 20900 25000 30800 28700 35850 33500 41300 46100 40907 46376 49750 37918 46089 53051 1/4" 6740 7800 8230 9325 13070 13850 19700 23700 29400 26800 33800 32000 39750 44650 38800 44188 47500 36321 44361 51600 3/8" Approx. Net Install. Wgt.(lbs.) 6400 7400 7260 8400 12300 13200 18600 22200 27900 24750 31600 30500 38250 43100 36796 41687 45350 34879 42947 49735 425 435 624 629 745 770 1012 1199 1254 1462 1577 1422 1476 1532 1750 1800 1860 1600 1650 1710 NOTE: Performance includes resistance through ventilator and shutters. RPM shown is nominal and performance is based on actual speed of test. Bold-type information provided in the Rating Table above is needed when preparing a model code. See Page 2 for the complete Hartzell Model Code Explanation and example. Bulletin A-157-K 28 www.hartzellfan.com 1 (800) 336-3267 Recirculating Hooded Roof Ventilator A dual purpose ventilator offering a simple, economical approach to energy conservation in lieu of complicated and costly heat recovery systems. The Series 27 provides roof ventilation, either exhaust or intake, plus the option of recirculating ceiling air and, if desired, mixing of ceiling air with ambient outside air. Standard Features • Sizes – 24", 30", 36", 42", 48", 54" and 60" Performance from 7,350 to 53,755 CFM (intake); 7,220 to 52,316 CFM (exhaust). • Construction – roof hood and base are constructed of painted galvannealed • • • • • Series 27 • • • steel as standard. The recirc section is 12 ga. hot rolled steel, painted. Also available in aluminum construction upon request. Propellers – one-piece cast aluminum reversible airfoil propeller in a direct drive reversible panel fan in the recirc section of the housing. Sizes – 24" to 42" – 6-blade – Type R Sizes – 48" to 60" – 6-blade adjustable – Type AAR Hinged Access Doors – two access doors are furnished as standard. Provide easy access to the motor operated shutter as well as the fan assembly. Shutters – heavy duty, center pivoted motor operated type. Louvers constructed of 16 ga. galvanized steel. One motor operator controls two shutters located in the lower recirc section. Motors – totally enclosed, air over fan duty motors are standard. Special motors are available upon request. Control Mode Package (NEMA 1) – specify mode package required. Mode #1 – INTAKE-RECIRC – provides intake ventilation plus the capability of recirculating ceiling air. Mode #2 – INTAKE-EXHAUST-RECIRC – for intake or exhaust operation, recirc shutter is closed; inlet-outlet shutter is fully open. For recirculation operation, fan pulls ceiling air through recirc shutter; inlet-outlet shutter is fully closed. Mode #3 – INTAKE-RECIRC-MIX – mix mode is used when a mixture of ambient outside air and warm ceiling air is required. Recirc shutter and intake shutter modulate to provide exact air mixture. Mode #4 – INTAKE-RECIRC-MIX-EXHAUST – provides intake or exhaust roof ventilation; also, recirculation of ceiling air; or a combination of ambient outside air and ceiling air. Starters – Each control mode package listed above is available with any of the following starters. Specify type required. TYPE A – starter only TYPE B – combination starter, non-fused disconnect. TYPE C – combination starter, fusible disconnect. (Modes 2 and 4 use reversing starters.) Control Installation – customer must supply wiring between the starter, remote control station, and the unit. Controls are shipped separately for mounting and wiring at job site. Units ordered without controls provided less damper actuators. Lifting Lugs – welded to the top of the plenum section furnished as standard for ease in handling this section during installation. Unit Installation – lower recirc section (containing fan and shutters, factory installed) and upper ventilator housing (base and hood), are shipped separately for assembly at job site. Recirc section drops through the roof for ease of installation. Accessories • Coatings – special protective coatings available upon request. • Diffusers – 2-and 4-way diffusers are available for all sizes. • Birdscreen – for installation in hood or throat section. Fabricated of 1/2" wire mesh. • Adapter Bases – slope or peak bases available. Specify slope per foot. • Prefabricated Curbs – available for flat, slope or peak roof mounting. Curbs are designed for metal, concrete or wood roof decks that are not surface insulated. Available either 8" or 12" high of galvanized or aluminum construction. See Page 34. Bulletin A-157-K 29 www.hartzellfan.com 1 (800) 336-3267 Principal Dimensions – Series 27 FAN SIZE A B C D E F G H J K L 24 241⁄4 281⁄4 70 361⁄4 153⁄4 72 36 13 1613⁄16 1027⁄16 13 30 311⁄4 351⁄4 741⁄2 431⁄4 171⁄2 80 43 16 18 5⁄16 10811⁄16 16 36 381⁄4 421⁄4 783⁄4 501⁄4 193⁄4 90 50 19 19 9⁄16 1153⁄16 19 42 44 ⁄4 48 ⁄4 83 ⁄4 56 ⁄4 21 96 56 22 21 ⁄16 120 ⁄16 22 48 501⁄4 541⁄4 861⁄4 621⁄4 261⁄4 120 62 25 211⁄16 1293⁄16 25 54 561⁄4 601⁄4 893⁄4 681⁄4 305⁄8 140 68 28 219⁄16 1371⁄16 28 60 621⁄4 661⁄4 933⁄4 741⁄4 33 1505⁄8 74 31 229⁄16 1437⁄16 31 1 1 1 1 F 4 3/8 SQ. OUTSIDE 18 GA. GALV. 1 15 OPTIONAL–FILTER RAILS OPTIONAL–DISPOSIBLE OR PERMANENT FILTERS LIFTING LUGS OPTIONAL BIRD SCREEN (SHOWN IN THROAT) E K 2 1/4 LIFTING HOOKS (2) REQ’D LOCATED IN DIAGONALLY OPPOSITE CORNERS 14 GA. GALV. D SQ. I. D. BASE 16 5/8 O. D. G SQ. FLANGE 7 GA. *24 REF. C CENTER PIVOTED MOTOR OPERATED SHUTTER SQ. 12 GA. H. R. S. B I.D. 12 SHUTTER MOTOR AND LINKAGE ACCESS DOORS 4 H L SHUTTER OPENING ACCESS OPENING 24 OPENING CENTER PIVOTED MOTOR OPERATED SHUTTER * 24" IS STANDARD DIMENSION CUSTOMER TO CHECK AND MAKE SURE SHUTTER ACCESS DOOR CLEARS ALL CEILING STRUCTURES TEMPERATURE CONTROLLER J J OPTIONAL DIFFUSER A REVERSIBLE PANEL FAN SHOWN DIFFUSER I. D. Rating Table – Series 27 Size 24" 30" 36" 42" 48" 54" 60" No. of Blades 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Blade RB RA RA RB RA RB R AR AR AR AR AR AR AR AR AR AR AR AR AR Blade Angle 25° 29° 25° 29° 24° 28° 29° 22° 27° 22° 28° 20° 25° 28° 22° 26.5° 28° 16° 19.5° 22.5° Motor HP 1 11⁄2 1 11⁄2 2 3 3 3 5 3 5 5 71⁄2 10 5 71⁄2 10 5 71⁄2 10 Code H I H I J K K K L K L L M N L M N L M N Motor RPM 1750 1750 1160 1160 1160 1160 870 870 870 690 690 870 870 870 690 690 690 870 870 870 Code 3 3 4 4 4 4 5 5 5 6 6 5 5 5 6 6 6 5 5 5 Peak Fan BHP 1.12 1.59 1.15 1.5 2.1 2.45 3.6 3.4 5.6 3.2 5.4 4.8 7.6 10 5.3 7.71 8.9 5.3 7.96 10.76 CFM @ S.P. – INTAKE 0" 7350 8300 9400 10450 14550 15500 21000 26600 32000 30250 37400 34250 42600 47300 41400 48148 51100 38100 46454 53755 1/8" 1/4" 3/8" Approx. Net Install. Wgt.(lbs.) 6875 7850 8250 9120 12625 13600 19250 24650 29750 27750 34400 32250 40000 44350 38700 44292 47350 36000 43882 50774 6510 7500 7450 8300 12100 13000 18600 23500 28400 26000 32500 31000 38300 42600 36500 42208 45200 34650 42390 49335 6180 7125 6500 7300 11600 12350 17200 22250 26800 24000 30350 29500 36800 41250 34500 39915 43000 33000 40949 47793 742 752 1027 1032 1256 1283 1451 1871 1926 2295 2410 2255 2305 2365 2740 2800 2860 2590 2645 2700 CFM @ S.P. – EXHAUST 1/8" 1/4" 3/8" 7000 8000 8800 9800 13800 14750 19950 25300 31000 28500 35500 33000 41000 46000 39300 45855 49000 36750 45065 52162 6650 7650 8050 9100 12975 14000 19000 24250 29450 26750 33500 31600 3950 44250 37400 43510 47000 35200 43470 50620 6300 7250 7100 8100 12250 13300 18000 23000 28000 25000 31500 30200 38000 42600 35500 41270 44500 33800 41670 49130 0" 7220 8200 8820 9750 13300 14250 20180 25750 31000 29300 36350 33500 41300 45900 40200 46533 49400 37300 45374 52316 NOTE: Performance includes resistance through ventilator and shutters. RPM shown is nominal and performance is based on actual speed of test. Bold-type information provided in the Rating Table above is needed when preparing a model code. See Page 2 for the complete Hartzell Model Code Explanation and example. Bulletin A-157-K 30 www.hartzellfan.com 1 (800) 336-3267 Roof Ventilator Application Rate of Air Change Method Industrial, commercial, and residential spaces need proper ventilation to facilitate a healthy and protective environment for people, inventory, machinery, and structures. Ventilation itself may be affected in a variety of ways, beginning with opening windows and doors. Typical industrial processes generate heat; people generate heat; and building structures pass solar heat gains. Warm air rises and can be trapped if not properly allowed to escape causing stratification of air layers and contaminated conditions. Power roof ventilators are an effective and efficient alternative to ventilation by convection. The proper application and use of power ventilators allows better control of air patterns and air distribution. Good, general ventilation practice and design ensures proper dilution ventilation, heat load control, contaminated air exhaust, and fresh air supply. As a result, operating personnel will be more comfortable and efficient; manufacturing equipment and processes will be able to function more properly. The rate of air change will vary with the type of structure, but a generally accepted rate is one air change every 5 minutes. Air volume is found be determining the plant volume in cubic feet to be ventilated and then dividing the cubic feet by the desired rate of air change. EXAMPLE: Ventilated area 120' x 50' x 20' = 120,000 cu. ft. Air Exchange Rate - change every 5 minutes. 120,000 cu. ft. = 24,000 CFM 5 min Plant Layout The usual method of designing plant ventilation layout is to first determine the amount of CFM required (see above). Secondly, determine the size and number of units needed to meet requirements. The units are generally symmetrically spaced. EXAMPLE: Ventilated area 120' x 50' x 20'. Air Exchange Rate - one change every 5 minutes. 120,000 cu. ft. = 24,000 CFM required 5 min. Determine number of ventilators required: Divide 24,000 CFM (system requirement) by number of units desired – in this case 2. Capacity requirement for each ventilator – 12,000 CFM. Symmetrical spacing should be used whenever possible; however, care must be taken to adequately ventilate particularly troublesome areas and that the roof ventilator air supply is not short cycled by open windows, air supply unit or wall louvers. Selection of Power Roof Ventilators Circulating Air Volume The rate of air change is the most frequently used method for calculating air volumes for general conditions. It is based on the theory that a complete air change must be within a certain interval. Listed below is a recommended guide for average air changes for general ventilation. Minutes Per Change Assembly Halls . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Auditoriums . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Bakeries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Boiler Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Bowling Alleys . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Churches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15 Dairies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Dance Halls . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Dry Cleaners . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Engine Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Factories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Forge Shops . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Foundries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Garages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Generator Rooms . . . . . . . . . . . . . . . . . . . . . . . .2-5 Gymnasiums . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Kitchens – Hospital . . . . . . . . . . . . . . . . . . . . . . .2-5 Kitchens – Restaurant . . . . . . . . . . . . . . . . . . . . .1-3 Laboratories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Laundries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Machine Shop . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Markets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Mills . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Offices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Packing Houses . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Plating Rooms . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Printing Plants . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 Toilets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 Transformer Rooms . . . . . . . . . . . . . . . . . . . . . . .1-5 Warehouses . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 120' 25' 50' Bulletin A-157-K 31 40' www.hartzellfan.com 1 (800) 336-3267 Exhaust and Supply Application Considerations Proper ventilation design is not limited to exhaust only. Any volume of air that is exhausted from a space must be made up by supply air in some fashion. Exhaust air will be made up to a space either naturally, by entering through building cracks, open doors, etc., or by proper ventilation design. Therefore, air supply, in addition to air exhaust, should be considered. In cooler climates tempered make-up air should be considered. To effect proper sweeps and flows through the area to be ventilated, supply air may be introduced through the side walls or the roof. Contact your local Hartzell representative for additional information on wall ventilators and make-up air units. In many cases it may be necessary to filter the supply air. Please see page 22. There are basically two power roof ventilator configurations. Upblast units are available for exhaust applications. They are designed to throw the exhaust air volume up and away from the building. When properly designed, exhaust air flow in operation prevents the entry of weather; backdraft dampers close securely to prevent air return and leakage when a unit is not in operation. Hooded roof ventilators are available for exhaust or supply. In the supply mode, hooded roof ventilators can be fitted with permanent or disposable filters. When properly designed, the ventilator hood accommodates low air velocities so as to minimize static pressure losses through the hood and prevent entrainment of weather when used in the supply mode. In addition, Hartzell offers a complete line of 100 percent reversible roof ventilators when periodic operation in either mode may be required. Recirculating power roof ventilators which are designed to intake fresh air, exhaust plant air, or recirculate clean plant air are also available. Your Hartzell sales representative can provide more information on these standard units. When a need for power roof ventilation has been identified and your initial design and selections made, you should consider the following items to ensure a proper, functional, and satisfactory selection: • Maintenance – power roof ventilators are available in direct- and belt-drive. Air quality, air temperature, and maintenance requirements for belts and bearings should be considered. Accessibility for maintenance of the ventilator and accessory items is an important issue. • Installation – power roof ventilator weights and sizes should be considered for lifting methods and mounting on the roof. Proper roof opening sizing, and free area in the opening are essential. Power roof ventilators should be secured to the building structure properly by means of attachment to a permanent structure or a pre-fabricated roof curb (see page 34). • Power Supply – care should be taken to specify proper voltage, phase and cycle for the power roof ventilator motor as well as accessories and controls. • Wind – care should be taken to ensure that exhaust and supply fan layout on the roof works with, rather than against, the prevailing winds. For example, when power roof exhaust and supply units are both used on the same roof, exhaust fans should be positioned down wind of supply fans. In addition, wind loads should be considered and standard units modified or reinforced to operate properly in high-wind conditions (see page 34). • Options – see pages 33 and 34 for typical standard options and accessories. Hartzell Fan, Inc. is able to modify standard products and accessories to meet your special requirements. Furthermore, for variable exhaust and supply requirements, your Hartzell sales representative can assist you in the proper application of AC speed controls with power roof ventilators. Design assistance for proper plant ventilation is available through recommended practices in industrial publications. However, your Hartzell representative can provide you with selection and application assistance based on experience with a variety of solutions to general and process ventilation problems. Contact your authorized Hartzell sales representative today. Ambient Conditions The ambient air temperature and air quality require attention when power roof ventilators are being selected. Extreme heat or cold may require special motor insulation (see the table that follows) or bearings, lubricants, belts, and materials of construction. Motor Insulation Standard Class F Class H Class HH Maximum Ambient Temperature 105°F 140°F 176°F 212°F Note: For extreme heat or cold, contact your Hartzell Sales Representative. Corrosive fumes or dust in the air stream may require special materials of construction or coatings. For some extreme corrosive applications, Hartzell offers a complete line of upblast and hooded fiberglass roof ventilators. Contact your Hartzell sales representative for more information on the availability and application of these products. Noise Power roof ventilators generate sound at different levels depending on their power, efficiency, operating speed, and overall design. This sound may be air borne or structure borne and should be considered in accordance with industrial safety and hygiene regulations. Slow-speed, high-volume, belted roof ventilators (Series 16) are typically well suited for these applications. In severe cases, attenuating devices and materials may be applied. In addition to in-plant requirements, sound power levels at the property line should also be considered. Typical Application – Series 26 The Series 26, Recirculating Roof Ventilators and Series 27, Recirculating Hooded Roof Ventilators provide roof ventilation during the summer months and heat recovery in winter by recirculating warm air from the ceiling down to floor level. During the summer months not much can be done with hot ceiling air but to exhaust it out of the plant by use of ventilators and exhaust fans. The huge reservoir of heated air resting at ceiling level can be recirculated for comfort heating during the cold winter months, providing the ceiling air is relatively clean and fume-free. In this age of rising fuel costs, it doesn’t make "economic sense" to exhaust warm ceiling air from a plant, then spend money for fuel to heat cool air for worker comfort and efficiency. Hartzell’s Recirculating Roof Ventilators were designed to economically solve both summer ventilation and winter heat recovery problems. More than 70 Hartzell offices can provide specific performance and installation data to meet your requirements. Call your Hartzell representative for technical assistance. EXHAUST AIR SUMMER ONLY WARM AIR WARM AIR RISING WARM AIR RISING RECIRCULATING AIR WINTER ONLY Bulletin A-157-K 32 www.hartzellfan.com 1 (800) 336-3267 Options and Accessories Bird Screen Stack Cap Options Half-inch square opening wire mesh, 19 ga. galvanized steel available for all ventilators. Aluminum bird screen also available. Special coating may require heavier gauge. Fiberglass Damper Lids Fiberglass lids in place of standard galvanized construction offers increased durability and longer lid life. An additional dividend is fiberglass insulation qualities resulting in less heat loss when the unit is idle during winter months. Series 61, 63 and 69 units only. Bird Screen Series 15, 16 and 17 Fusible Link Inspection Door – Series 69 Spring operated, positive lid opener for Series 61, 63 and 69 models. When the temperature through the ventilator exceeds 165°F, the fusible link allows the spring-operated lid opener to lock the stack cap lids in the upright position. Provides gravity ventilation in case electricity to the ventilator is interrupted during a fire. Series 69 is available with a hinged inspection door. Magnetic Latches For positive lid closure when unit is not in operation. Prevents lid flutter when positive pressure exists in building. Series 61, 63 and 69 units only. SAFETY ACCESSORIES, APPLICATION AND USE WARNING Disconnect Switch NEMA watertight enclosure available mounted and wired, provides safety during maintenance. The safe application and use of equipment supplied by Hartzell Fan, Inc. is the responsibility of the installer, the user, the owner, and the employer. Since the application and use of its equipment can vary greatly, Hartzell Fan, Inc. offers various product types, optional safety accessories, and sound performance data per laboratory tests. Hartzell Fan, Inc. sells its equipment with and without safety accessories, and accordingly, it can supply such safety accessories only upon receipt of an order. The need for safety accessories will frequently depend upon the type of system, fan location and operating procedures being employed. The proper protective safety accessories to meet company standards, local codes, and the requirements of the Occupational Safety and Health Act must be determined by the user since safety requirements vary depending on the location and use of the equipment. If applicable local conditions, standards, codes or OSHA rules require the addition of the safety accessories, the user should specify and obtain the required safety accessories from Hartzell Fan, Inc. and should not allow the operation of the equipment without them. Owners, employers, users and installers should read “RECOMMENDED SAFETY PRACTICES FOR USERS AND INSTALLERS OF INDUSTRIAL AND COMMERCIAL FANS” published by the Air Movement and Control Association International, Inc., 30 West University Drive, Arlington Heights, Illinois 60004. A copy of this publication is enclosed with each fan shipped from Hartzell Fan, Inc., and is available upon request at Hartzell’s office in Piqua, Ohio 45356. Please contact Hartzell Fan, Inc. or your local Hartzell representative for more information on product types, safety accessories, and sound performance estimates. Remember, the selection of safety accessories and the safe application and use of equipment supplied by Hartzell Fan, Inc. is your responsibility. Guard Painted steel guard protects floor area from falling debris and the ventilator from vandalism. Combination Motor Cover and Belt Guard Series 69 upblast ventilator only. Provides weather protection as well as guarding of the drive sheave and belts. Covers are vented. Extended Lube Tubes Extended Lube Tubes will be provided from the motor on direct drive units and from the bearings and motor on belt drive and belted units to the exterior of the housing only when the motor is designed for external lubrication fittings (relubricable versus sealed motor bearings). Coatings Non-standard coatings are available. A catalyzed coal tar epoxy offers excellent resistance to weather. Also available is an air dry epoxy offering a corrosive resistant ventilator. Other types of nonstandard coatings can be furnished. Standard paint is industrial grade enamel suitable for interior or exterior industrial applications. Contact your Hartzell representative for further information. Swing-Out Fan Construction Fan casing is split and hinged. Section containing fan, drive assembly and propeller swings open and away from installed ventilator. Provides service access to propeller and drive components. See pages 10 and 11. Bulletin A-157-K 33 www.hartzellfan.com 1 (800) 336-3267 Hooded Roof Ventilator Options Curb Adapter Base High Wind Load Construction All models available for flat, slope or peak base and are suitable for high wind loads due to tubular construction. Series 15, 16, 17 and 19 hooded ventilators are designed to withstand wind loads up to 60 mph. For wind loads between 60 mph and 90 mph, specify high wind load construction, which includes guy wires to secure hood to roof structure. PEAK Hood Roller Slide Rail M 12" Slide rail design is available in sizes 42" – 84". They consist of roller wheels, guide rails, and rigid supports for stability. This package allows the hood halves to be unbolted and rolled apart providing 100% accessibility to the fan assembly without having to remove either of the hood halves from the unit. M 12" SLOPE Prefabricated Curb The IRC-1 prefabricated curb is for flat roof installation of Hartzell roof ventilators. The curb is designed for metal, concrete or wood roof decks that are not surface insulated. The curb is available either 8" or 12" high. Sizes 12" - 60" only. For larger sized curbs, contact your Hartzell representative for assistance. Prefabricated curbs are designed to support the weight of the fans catalogued herein, and attachments not exceeding over 100 additional pounds in a 40 mph wind. Non-standard curb construction is available. SQ. 1-1/2" NEOPRENE SEALER 8" or 12" available SQ. Features: • Nailer Strip – built-in cant strip facilitates fastening the ventilator to the curb. • Glass Fiber Insulation – a rigid 1 1/2" thick 3 lbs. density liner eliminates condensation problems. • Neoprene Sealer – 1/4" strip. • Construction – galvanized steel (18 ga.) or aluminum (.063). • Welded Seams. Series 15, with optional filters and slide rail package Backdraft Dampers Available in galvanized steel, aluminum or coated construction, automatic, manual or motor operated configuration, factory installed. The damper is mounted in the base section of the ventilator. Access to the dampers is provided through a hinged type door with quick release latches. This door allows easy removal of dampers in fully open position. Principal Dimensions for Series 69 Fan Size 12 14 16 18 20 24 28 30 32 36 40 42 44 48 54 60 A 211/4 231/4 251/4 271/4 291/4 351/4 411/4 411/4 411/4 471/4 491/4 531/4 531/4 571/2 631/2 691/2 B 291/4 311/4 331/4 351/4 371/4 431/4 491/4 491/4 491/4 551/4 571/4 611/4 611/4 651/2 711/2 771/2 Principal Dimensions for Series 61 and 63 Fan Size 12 14 16 18 20 24 28 32 36 40 42 48 54 60 A 211/4 231/4 251/4 271/4 291/4 351/4 411/4 411/4 471/4 491/4 531/4 571/2 631/4 691/2 B 291/4 311/4 331/4 351/4 371/4 431/4 491/4 491/4 551/4 571/4 611/4 651/2 711/2 771/2 Principal Dimensions for Series 15, 16 and 17 Fan Size A B Access door showing mounting position for backdraft dampers. 18 291/2 371/2 24 351/2 431/2 30 421/2 501/2 36 491/2 571/2 42 551/2 631/2 48 611/2 691/2 54 671/2 751/2 60 731/2 811/2 Specifications and dimensions are subject to change. Certified prints are available. Principal Dimensions for Prefabricated Curbs – Series 27 Fan Size A B 24 351/2 431/2 30 421/2 501/2 36 491/2 571/2 42 551/2 631/2 48 611/2 691/2 54 671/2 751/2 60 731/2 811/2 Principal Dimensions for Prefabricated Curbs – Series 26 Fan Size A B Bulletin A-157-K 34 24 351/4 431/4 30 411/4 491/4 36 471/4 551/4 42 531/4 611/4 48 631/2 711/2 54 691/2 771/2 60 79 87 www.hartzellfan.com 1 (800) 336-3267 In addition to Power Roof Ventilators, a complete solution for your general ventilation needs... Propeller Fans and Wall Ventilators Propeller fans and wall ventilators are designed for general ventilation, fume removal, cooling, air supply or exhaust applications. Standard and Lo-Noise Ring Fans Sizes: 12" to 120" 1475 to 229,000 CFM at free air Request Bulletin A-109 Standard and Lo-Noise Panel Fans Sizes: 12" to 60" 1475 to 66,850 CFM at free air Request Bulletin A-109 Reversible Ring Fans Sizes: 18" to 60" 3350 to 49,800 CFM at free air Request Bulletin A-109 Belted High Volume Ring Fans Sizes: 72" to 144" 63,000 to 327,000 CFM at free air Request Bulletin A-109 Cool Blast Fans Cool blast fans are ideal for cooling personnel or equipment, smoke diffusion, product cooling and insect dissipation. Stationary Pedestal Fans Sizes: 20" to 48" 4168 to 32,700 CFM at free air Request Bulletin A-120 Portable Pedestal Fans Sizes: 20" to 48" 4168 to 32,700 CFM at free air Request Bulletin A-120 Stationary or Portable Utility Fans Sizes: 20" to 36" 4168 to 18,770 CFM at free air Request Bulletin A-120 HartKool Cooling Fans Sizes: 18" to 36" 4236 to 13,450 CFM at free air Request Bulletin A-120 Hartzell gas and steam fired make-up air equipment can be used to supply tempered make-up air or as a total fresh air heating system. Make-up air is needed in a plant to eliminate negative pressure in a building and the “sick building syndrome” associated with this problem. Hartzell also manufactures door heaters and unit heaters to complete plant heating requirements. Gas Fired Equipment Gas Fired Make-up Air Units 3,000 to 100,000 CFM Units 300,000 to 10,000,000 BTU/ HR Axial or Centrifugal Fan Sections. Request Bulletin A-125. Gas Fired Econo Units Heating capacities from 950,000 to 2,900,000 BTU/ HR Request Bulletin A-125 Gas Fired Door Heaters Heating capacities from 700,000 to 990,000 input BTU Request Bulletin A-125 Steam Fired Face and Bypass Units Axial or Centrifugal Assemblies Heating capacities from 740,000 to 4,000,000 BTU/ HR Request Bulletin A-128 Steam Unit Heaters With 1- or 2-row coils Heating capacities from 31,000 to 524,000 BTU/ HR Request Bulletin A-121 Steam Fired Equipment Steam Fired Makeup Air Units With Propeller Fan Assembly Heating capacities from 536,000 to 5,362,000 BTU/ HR Request Bulletin A-128 Steam Fired Makeup Air Units With Centrifugal Fan Assembly Heating capacities from 740,000 to 3,826,000 BTU/ HR Request Bulletin A-128 Bulletin A-157-K 35 www.hartzellfan.com 1 (800) 336-3267 Hartzell Warranty LIMITED WARRANTIES Hartzell represents to Buyer that any goods to be delivered hereunder will be produced in compliance with the requirements of the Fair Labor Standards Act of 1938 as amended. Hartzell also warrants to Buyer its goods to be free from defects in workmanship and material under normal use and service for one (1) year after tender of delivery by Hartzell, plus six (6) months allowance for shipment to approved stocking dealers & distributors. No warranty extends to future performance of goods and any claims for breach of warranty or otherwise accrues upon tender of delivery. The foregoing constitute Hartzell’s sole and exclusive warranties in lieu of all other warranties, whether written, oral, express, implied or statutory. LIMITATION OF LIABILITY FOR BREACH OF WARRANTY Hartzell’s obligation for any breach of warranty is limited to repairing or replacing, at its option, without cost to Buyer at its factory any goods which shall, within such a warranty period, be returned to it with transportation charges prepaid, and which its examination shall disclose to its satisfaction to have been defective. Any request for repair or replacement should be directed to Hartzell Fan, Inc., P.O. Box 919, Piqua, Ohio 45356. Hartzell will not pay for any repairs made outside its factory without its prior written consent. This does not apply to any such Hartzell goods which have failed as a result of faulty installation or abuse, or incorrect electrical connections or alterations, made by others, or use under abnormal operating conditions or misapplication of the goods. LIMITATION OF LIABILITY To the extent the above limitation of liability for breach of warranty is not applicable, the liability of Hartzell on any claim of any kind, including negligence, for any loss or damage arising out of or connected with, or resulting from the sale and purchase of the goods or services covered by these Terms and Conditions of Sale or from the performance or breach of any contract pertaining to such sale or purchase or from the design manufacture, sale, delivery, resale, installation, technical direction installation, inspection repair, operation or use of any goods or services covered by these Terms and Conditions shall, in no case exceed the price allocable to the goods or services which gave rise to the claim and shall terminate one year after tender of delivery of said goods or services. In no event whether as a result of breach of contract, or warranty or alleged negligence, defects incorrect advice or other causes, shall Hartzell be liable for special or consequential damages, including, but not limited to, loss of profits or revenue, loss of use of the equipment or any associated equipment, cost of substitute equipment, facilities or services, down time costs, or claims of customers of the Buyer for such damages. Hartzell neither assumes nor authorizes any person to assume for it any other liability in connection with the sale of its goods or services. NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS. HARTZELL DOES NOT WARRANT THAT SAID GOODS ARE OF MERCHANTABLE QUALITY OR THAT THEY ARE FIT FOR ANY PARTICULAR PURPOSE. THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY AND THERE IS NO IMPLIED WARRANTY OF FITNESS. Propeller Fans Cooling Tower & Heat Exchanger Fans Duct Fans Vaneaxial Blowers Cool Blast & Utility Fans Steel Centrifugal Blowers Fiberglass Axial Flow Fans Fiberglass Centrifugal Blowers Heating Equipment – Gas & Steam Duct Axial Fans Roof Ventilators – Steel & Fiberglass Marine – Mine Duty Blowers Hartzell Fan, Inc., Piqua, Ohio 45356 • Plants in Piqua, Ohio and Portland, Indiana. www.hartzellfan.com Litho in U.S.A. A-157-K 11/05 3M