Data Centers using RASER

Transcription

Data Centers using RASER
R.A.S.E.R.™ Product Brief
•Up To 50% $ Savings on Electricity
•Patented closed loop cooling system (Zero Bypass, Enclosed Hot
and Cold Aisle
•50-80% More efficient = Green
•Up To 75% Floor Area Savings
•RASER is 850W/sqft Delivers 85ft² of “equivalent raised floor”
space in 20ft²
•Fireproof and Water Proof
•Air Tight Closed Loop System
•Eliminates Shock and Vibration Damage
•Patented Equipment Suspension
•Scalable from 1 Micro Data Center to 100’s; “Pay as You Need”
•Affordable Small and Medium Size Business Data Center Ownership
Copyright Elliptical Mobile Solutions 2009
1
R.A.S.E.R.™
is available in several different
configurations
•12KW 600W/ft² Self Contained
•12KW DUAL HVAC Self Contained
•17KW 850W/ft² Self Contained
•20KW on Product Roadmap 1000W/ft²
Includes the following:
Keyed Lock System
•42000 BTU single or double rear door mounted air
conditioner
•Patch Panel/switch side car
•Basic suspension system for shock/vibration
isolation
Optional Upgrades:
•Cyberlock Security Key System and software
•Aerogel fireproof insulation
•Redundant air conditioning system
Interior Lighting
IP addressable PDU’s
•Extreme Seismic/ Shock and Vibration Control
Complete Hot And Cold Aisle Containment
Air Loop 1
ZERO BYPASS Air Loop 2
Equipment
Ambient In
Hot out
Heat Ducted
out of data
center floor
H
o
t
A
i
s
l
e
Equipment
Equipment
Equipment
Equipment
Equipment
Cold Air
C
o
l
d
A
i
s
l
e
ALL EMS PRODUCTS
ENCLOSE THE HOT AND
COLD AISLE; REDUCING
POWER REQUIRED TO COOL
BY 50%
Traditional Hot/Cold open aisle
Not efficient at high density
Uptime Institute White Paper
HPC High Performance Computing Data Center Application Brief
“the cost of building a new facility is approaching $2,500 a square foot.”
Dan Golding, vice president and research director of Tier1 Research. April 2009
STATE OF THE ART
“TRADITIONAL
WAY”
•Broken System
•Custom
•Long Lead Time
•Inflexible
•Requires remodel
every five years
60 ft
Offices/Support
Equipment
70
ft
High Security Area
$12,500/KW
capacity
Build Cost
Raised Floor
(Racks/HVAC/Servers)
840KW Compute
14KW/Rack
200W/ft² Design
4,200 ft² x $2,500=$10,500,000
Copyright Elliptical Mobile Solutions 2009
50 X
EMS WAY
Data Centers using RASER
60 ft
Offices/Support
Equipment
60
ft
•Energy Efficient
•Easy to Expand
•Easy to Relocate
•Site Management in
Warranty
•Scalable
•Modular
•“Pay as You Go”
RASER Area
RASER
•Physical Security
•Electronic Security
•Fireproofing
•Watertight
840KW Compute
17KW RASER
708W/ft² Design
3600ft² x $150 = $540,000 Building Shell
50 x $68,000 RASER=$3,400,000
$3,940,000 Standardized Modular
Compute Space
Copyright Elliptical Mobile Solutions 2009
$4,500/KW
capacity
Build Cost
63% SAVINGS FOR
SAME COMPUTER
POWER
Large Data Center Build
10,000ft² white floor
2,000ft² office space
207 12KW R.A.S.E.R.
2.484 MW Capacity
$12,420,000 RASER
$1,800,000 Building ($150/ft²)
$14,220,000 Total CapEx
Soft Office Space
•All RASERS can be moved
out/replaced during technology
refresh
•White floor is bare concrete
•High volume exhaust fans remove
heat from white floor space
VS.
Tier II Traditional Data Center
16,500ft² raised floor (150W/ft²design)
2,000ft² office space
2.484 MW Capacity
$31,050,000 Total CapEx
55% CAPITAL COST
SAVINGS
White Floor Density: 220W/ft² Design
Copyright Elliptical Mobile Solutions 2009
Large Data Center Build
Soft Office Space
9,100ft² white floor
2,000ft² office space
351 12KW R.A.S.E.R.
4.212 MW Capacity
$21,420,000 RASER
$3,330,000 Building ($300/ft²)
$25,750,000 Total CapEx
•All R.A.S.E.R.S. stationary
•White floor is bare concrete
•High volume exhaust fans remove
heat from white floor space
VS.
Tier II Traditional Data Center
28,080ft² raised floor (150W/ft²design)
2,000ft² office space
4.212 MW Capacity
$52,650,000 Total CapEx
53% CAPITAL COST
SAVINGS
White Floor Density: 450W/ft² Design
Copyright Elliptical Mobile Solutions 2009