Data Centers using RASER
Transcription
Data Centers using RASER
R.A.S.E.R.™ Product Brief •Up To 50% $ Savings on Electricity •Patented closed loop cooling system (Zero Bypass, Enclosed Hot and Cold Aisle •50-80% More efficient = Green •Up To 75% Floor Area Savings •RASER is 850W/sqft Delivers 85ft² of “equivalent raised floor” space in 20ft² •Fireproof and Water Proof •Air Tight Closed Loop System •Eliminates Shock and Vibration Damage •Patented Equipment Suspension •Scalable from 1 Micro Data Center to 100’s; “Pay as You Need” •Affordable Small and Medium Size Business Data Center Ownership Copyright Elliptical Mobile Solutions 2009 1 R.A.S.E.R.™ is available in several different configurations •12KW 600W/ft² Self Contained •12KW DUAL HVAC Self Contained •17KW 850W/ft² Self Contained •20KW on Product Roadmap 1000W/ft² Includes the following: Keyed Lock System •42000 BTU single or double rear door mounted air conditioner •Patch Panel/switch side car •Basic suspension system for shock/vibration isolation Optional Upgrades: •Cyberlock Security Key System and software •Aerogel fireproof insulation •Redundant air conditioning system Interior Lighting IP addressable PDU’s •Extreme Seismic/ Shock and Vibration Control Complete Hot And Cold Aisle Containment Air Loop 1 ZERO BYPASS Air Loop 2 Equipment Ambient In Hot out Heat Ducted out of data center floor H o t A i s l e Equipment Equipment Equipment Equipment Equipment Cold Air C o l d A i s l e ALL EMS PRODUCTS ENCLOSE THE HOT AND COLD AISLE; REDUCING POWER REQUIRED TO COOL BY 50% Traditional Hot/Cold open aisle Not efficient at high density Uptime Institute White Paper HPC High Performance Computing Data Center Application Brief “the cost of building a new facility is approaching $2,500 a square foot.” Dan Golding, vice president and research director of Tier1 Research. April 2009 STATE OF THE ART “TRADITIONAL WAY” •Broken System •Custom •Long Lead Time •Inflexible •Requires remodel every five years 60 ft Offices/Support Equipment 70 ft High Security Area $12,500/KW capacity Build Cost Raised Floor (Racks/HVAC/Servers) 840KW Compute 14KW/Rack 200W/ft² Design 4,200 ft² x $2,500=$10,500,000 Copyright Elliptical Mobile Solutions 2009 50 X EMS WAY Data Centers using RASER 60 ft Offices/Support Equipment 60 ft •Energy Efficient •Easy to Expand •Easy to Relocate •Site Management in Warranty •Scalable •Modular •“Pay as You Go” RASER Area RASER •Physical Security •Electronic Security •Fireproofing •Watertight 840KW Compute 17KW RASER 708W/ft² Design 3600ft² x $150 = $540,000 Building Shell 50 x $68,000 RASER=$3,400,000 $3,940,000 Standardized Modular Compute Space Copyright Elliptical Mobile Solutions 2009 $4,500/KW capacity Build Cost 63% SAVINGS FOR SAME COMPUTER POWER Large Data Center Build 10,000ft² white floor 2,000ft² office space 207 12KW R.A.S.E.R. 2.484 MW Capacity $12,420,000 RASER $1,800,000 Building ($150/ft²) $14,220,000 Total CapEx Soft Office Space •All RASERS can be moved out/replaced during technology refresh •White floor is bare concrete •High volume exhaust fans remove heat from white floor space VS. Tier II Traditional Data Center 16,500ft² raised floor (150W/ft²design) 2,000ft² office space 2.484 MW Capacity $31,050,000 Total CapEx 55% CAPITAL COST SAVINGS White Floor Density: 220W/ft² Design Copyright Elliptical Mobile Solutions 2009 Large Data Center Build Soft Office Space 9,100ft² white floor 2,000ft² office space 351 12KW R.A.S.E.R. 4.212 MW Capacity $21,420,000 RASER $3,330,000 Building ($300/ft²) $25,750,000 Total CapEx •All R.A.S.E.R.S. stationary •White floor is bare concrete •High volume exhaust fans remove heat from white floor space VS. Tier II Traditional Data Center 28,080ft² raised floor (150W/ft²design) 2,000ft² office space 4.212 MW Capacity $52,650,000 Total CapEx 53% CAPITAL COST SAVINGS White Floor Density: 450W/ft² Design Copyright Elliptical Mobile Solutions 2009