ZEPHYRUS
Transcription
ZEPHYRUS
ZEPHYRUS HVAC & Waste Energy Recovery Solution provider CHP Solution Inc. Zephyrus CHILLER CHP Solution Korea Co.,Ltd Hot Water driven Absorption Chiller CHP Solution Inc. GREEN Technology CHP Solution, Absorption Machines Provide the best solution for CHP and CCHP application by utilizing waste heat more efficiently. No CFC’s and Environmentally safe Low Noise & Low Vibration Operation Precise & Optimized Control by PLC Saving of Initial Investment High Reliability by Few Moving Parts Contents 4 About Products 10 Engineering Data 49 Guide Specifications CHP Solution Inc. Nomenclature Identification Rule SAB-HW052G1 SAB = Absorption Chiller HW = Hot Water Driven Absorption Chiller DF = Direct Gas Fired Absorption Chiller & Heater SF = Steam Driven Absorption Chiller MW = Two Stage Hot Water Driven Absorption Chiller LW = Single Effect Double Lift Hot Water Driven Absorption Chiller 052 = x 10 = Cooling Capacity ( Nominal Ton ) 1 = Model Version number, 0,1,2,3… CHP Solution Inc. Line Up Model 0 250 500 750 1000 1250 1500 SAB-DF-N, G SERIES SERIES 120usRT 1250usRT Direct Fired Absorption Chiller & Heater(N-COP based on 1.0 at HHV) Direct Fired Absorption Chiller & Heater(G-COP based on 1.2 at HHV) SAB-DF-E SERIES 120usRT 1000usRT Direct Fired Absorption Chiller & Heater(COP based on 1.32 at HHV) SAB-DF-E0J SERIES 120usRT 1000usRT Waste Heat(Hybrid) Absorption Chiller & Heater(Gas+Hot water) SAB-SF-N, G SERIES 120usRT 1250usRT Steam Driven Absorption Chiller(N-Steam consumption ratio is 4.4kg/h.RT) Steam Driven Absorption Chiller(G-Steam consumption ratio is 3.9kg/h.RT) SAB-SF-E SERIES 120usRT 1000usRT Steam Driven Absorption Chiller(Steam consumption ratio is 3.6kg/h.RT) SAB-HW-G SERIES SERIES 15usRT 1000usRT Hot water Driven Absorption Chiller(Hot water in/out temp. is 95-80℃) SAB-MW,LW-G SERIES 65usRT Tow Stage Hot Water Driven Absorption Chiller (Hot water in/out temp. is 95-68℃) Single Effect-Double Lift Hot water Driven Absorption Chiller (Hot water in/out temp. is 95-55℃) 1500usRT CHP Solution Inc. Product Feature CHP Hot water driven Absorption Chiller provides economical Water chilling for CHP (Cooling, Heating and Power) System. Heat recovery cooling and Excellent part load performance Exhaust-energy water chilling – CHP Hot water driven absorption chiller produces cooling from Exhaust or Solar energy. Also, the use of hot water driven absorption chiller eliminates demand charges and high cost electrical usage. Application versatility Designed to suit a variety of applications - From comfort cooling to providing chilled water for process applications, the CHP absorption chiller offers versatility for almost any job where hot water is available as the heat source, the CHP is sure to be the right choice for either new construction or retrofit applications. Excellent part load performance - CHP standard concentration control system allows stable, part load operation at cooling water temperatures as low as 65℉(18℃) without the need for a cooling water bypass. For maximum efficiency, a variable frequency drive pump (option) automatically maintains optimum solution flow between generator and absorber at all operating condition. This will result in improved part-load efficiency. The CHP has a continuous operating range from 100% to 25% of rated machine capacity. Location and installation savings Ease of installation - CHP Absorption chillers are completely fabricated, assembled and wired in the factory as single-piece units. Single-point box electrical connection Installation costs are further reduced by eliminating field wiring between machine components. On units shipped as a single assembly, all unitmounted electrical items are factory-wired to the chiller microprocessor control panel. Only a singlepoint electrical connection to the chiller from the building’s electrical service is required. Voltage transformers, mounted in the chiller control panel, provide secondary, single-phase powers for the CHP control. Low noise and vibration allows location flexibility - Low sound and vibration levels are characteristic of absorption chillers, primarily due to the fact the only rotating parts are the refrigerant and solution pumps. The overall sound level of CHP is typically 75dbA. This allows the machines to be installed near occupies spaces or in areas with strict sound requirements. Low vibration levels also make it possible to install the chiller on upper floors without special consideration for vibration dampening systems. Low maintenance Standard features allow simple maintenance procedures - Every CHP machine has numerous standard design features that provide for convenient and simple maintenance. All moving parts are easily accessible for inspection or replacement, as required. Leak-proof hermetic pumps cut maintenance costs - CHP solution and refrigerant pumps/ motors are leak-proof, completely self-contained, and hermetically sealed. The hermetic design eliminates the need for a separate, complicated, and possibly leak-prone seal water system while providing leak tightness and longer machine life. Specially designed bearings absorb both radial and axial thrusts to ensure correct fit at all times. There is no possibility of external contamination since the fluid being pumped lubricates and cools the pump and motor assemblies. In addition, both the rotor and the stator are separated by a stainless steel liner that protects the windings from the fluid being pumped. As an additional safety feature, thermal over-load switches are embedded in the stator to protect against high winding temperatures. The pumps are field serviceable. Inspection is recommended after 5 years or 20,000 hours of operation, whichever comes first. Pump isolation valves are included on CHP machines to make field service easy, if required. Reliable operation CHP control system features automatic microprocessor control center continuously monitors machine operation, ensuring precise control – Each CHP absorption chiller includes a factory mounted and wired microprocessor control panel that is functionally tested prior to shipment. Continuous monitoring and control of machine operation are performed automatically. A touch screen type display on the front of the control panel identifies operational status and fault indication. All control panel components and the assembly will meet local codes including UL CHP Solution Inc. (Underwriters’ Laboratories), CE and KS where appropriate and include a microprocessor CPU (central processing unit) board, molded case circuit breaker, pump contactors, ambient compensated 3-phase pump overload protection, control power transformers, and all other necessary safeties and controls. As part of the start-up sequence, the chiller microprocessor control panel initiates a selfdiagnostic system check to verify that all sensors are in range. Other standard features include a remote start/stop switch and a key-locked control panel door that protects against unauthorized access. Superior corrosion protection – Absorption chillers must be protected from the possibility of internal corrosion that is always present when lithium bromide solution is in contact with internal machine surfaces. The CHP absorption chiller incorporates a highly effective corrosion inhibitor to provide an extra margin of protection against internal corrosion. Other inhibitors may require the use of exotic tube materials in certain heat exchangers since they are less effective and require frequent maintenance and analysis. The superior corrosion protection of CHP’s inhibitor allows for the use of standard copper tubes throughout the machine. This results in long machine life and dependable operation. Gravitational dropping refrigerant and solution distribution system (Evaporator, Absorber) – The refrigerant and solution distribution system in evaporator and absorber is performed based on gravity and siphon phenomenon. This gravitational dropping distribution system adopts stainless steel tray and allows uniform solution spray and continuous heat transfer. Different from nozzle spray type of distribution system, this system does not need external pumps to spray the solutions with nozzles and prevents nozzles from clogging. Rugged machine construction – Every CHP absorption chiller offers numerous standard features designed to provide reliable, trouble-free operation. The machine is fabricated to meet stringent manufacturing and design requirements. Automatic purge system (Option) extends machine life and ensures optimum efficiency and performance – The purge system of an absorption chiller is critical to ensuring efficient operation and long machine life. Even when machines are vacuum tight or properly inhibited, all absorption chillers generate hydrogen and other non-condensable gases in small quantities. Since these gases are present in sufficient volume to interfere with proper machine operation, they must be removed to protect the unit from internal corrosion, lithium bromide solution crystallization, and/or a reduction in chiller capacity. CHP purge system protects the machines from these potential hazards by working continuously during machine operation. During operation, non-condensable gas tends to accumulate in the absorber section, which operates at the lowest internal pressure. A slipstream of lithium bromide solution from the solution pump discharge flows through an eductor, creating a suction that draws non-condensable gas from the absorber. The non-condensable gas is then entrained by the solution flowing through the eductor. The eductor discharges the solution and non-condensable gas into a separator in a purge chamber, where the non-condensable gas are separated from the solution. The non-condensable gas flows to a storage tank, while the solution returns to the absorber pump. As non-condensable gas accumulates in the external storage tank, they are isolated from the chiller and cannot reenter the machine (even during shutdown). These gases must periodically be exhausted (as required) from the storage tank by a simple procedure performed while the machine is running. Evacuation can be performed by a unit-mounted vacuum pump that is connected to the purge evacuation valve. The unit-mounted vacuum pump can also be used during chiller maintenance or service to remove non-condensable gas directly from the machine. CHP Solution Inc. Controls Control Algorithm PLC Controller Climatix Controller [ POL-63x.xx] sensors on board • 4 relay outputs • 2 triac outputs (AC 24 V…230 V) • 1 digital input galvanically isolated for AC 115/230 V. * POL-945 • 4 analog inputs (can be configured separately as digital inputs) • 4 relay outputs ■ POL-925 • 4 digital inputs for potential-free contacts • 2 digital inputs galvanically isolated for AC 115/230 V Touch screen 15 I/O module [POL-965] ■ XT07CD-7 The controllers offer the following features: ■ POL63x Controller • Freely programmable •Object-oriented programming by graphic editor SAPRO • Expandability via peripheral bus for local or Remote I/O extension modules • Power supply AC 24 V or DC 24 V • 8 universal I/Os (configurable inputs / outputs, for analog or digital signals) • DC 24 V onboard power supply for active sensors • 5 digital inputs (potential-free contacts) • 2 analog outputs (DC 0…10 V outputs) • 6 relay outputs (NO contacts) • RS-485 in Modbus RTU model for third-party bus • Full modem RS-232 port for remote service • Process bus for connecting room units and remote HMI (DPSU) • Up to 3 additional communication modules for BACS integration • Local service connector for user interface (RJ45) and PC tools (USB) • SD card for application and operating system upgrade • LON field bus (POL636.00 only) • Ethernet port for remote or local servicing using standard browsers(POL638.00 only) • Operating temperature -20…60 °C (without LCD – 40…70 °C) ■ POL-965 • 8 universal I/Os • AC 24 V and DC 5 V power supply for active • Panel size : 7” color display • OS : Window CE 6.0 • Memory : 128Mb DDR2 • Storage : 128Mb SLC NAND FLASH • Pixel : WVGA 800x480 • Touch type : Analog • Font : Korea, Chinese, Japan, English image font • Comm. : RS-232/422/485 • USB Host. : 1 Port • Power supply DC 24 V Ethernet Monitoring & Control System We provide remote control system with Ethernet based protocol for chiller operating data monitoring. Moreover remote start/stop, change setting values of the chiller operating. And we can inspect and control all operating data and forecast the alarm or malfunction. So, we recommend better setting data and how to take action. Central Monitoring System Remote monitoring and control system allow operators to check and control Cention Chiller remotely via internet or direct connection. • Easily accessible to user’s interface • Operational data acquisition • Graphical display of monitoring & control status • Real time graphical display of trend data • Various graphic display for analog data CHP Solution Inc. ENGINEERING DATA All products are qualified of reliability at factory test facility before shipments, and the products are upgraded continuously through the records of test and field experiences. Single Effect Hot Water Absorption Chiller CHP Solution Inc. COOLING WATER OUTLET HOT WATER OUTLET HOT WATER INLET CYCLE DIAGRAM FOR HW-G SERIES T4 V11 T5 T6 PURGE EJECTOR SAFETY VALVE V12 CHILLED WATER OUTLET EVAP T2 ABSO PURGE TANK V14 69WC T9 MANOMETER T10 CHILLED WATER INLET V13 P T1 V8 COMPOUND GUAGE V15 MS T7 V10 SOL. SP PUMP V9 PURGE SOLENOID VALVE V3 GAS SEPARATOR V7 : FLOW SET VALVE : FLOAT VALVE : SERVICE VALVE : DIAPHRAGM VALVE : SAFETY VALVE V4 MS 26RL V2 MR REF.PUMP V5 V1 MP VACUUM.PUMP HX V6 SOL.PUMP COOLING WATER INLET : ANGLE VALVE T8 T3 V16 : SHUT OFF VALVE Single Effect Hot Water Absorption Chiller CHP Solution Inc. Specifications SAB-HW Series SAB-HW Model Item Cooling Capacity Temperature Chill ed Wat er Coo ling Wat er Hot wat er 001G1 002G1 003G1 004G1 005G1 006G1 008G1 010G1 usRT 15 20 30 40 50 65 80 100 kW 53 70 105 141 176 229 281 352 Mcal/h 45 60 91 121 151 197 242 302 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 9.1 12.1 18.1 24.2 30.2 39.3 48.4 60.5 Pressure drop kPa 41 41 52 52 49 54 62 89 Pipe size(DN) mm 32 40 80 100 Temperature ℃ 50 65 Inlet 31 Outlet 36.5 Flow rate ㎥/h 20 26 39 52 65 85 105 130 Pressure drop kPa 50 51 46 51 64 80 89 83 Pipe size(DN) mm 50 Temperature ℃ 65 80 100 Inlet 95 125 Outlet 80 Flow rate ㎥/h 4.3 5.7 8.6 11.4 14.3 18.5 22.8 28.5 Pressure drop kPa 12 21 30 53 46 40 49 55 Pipe size(DN) mm 25 Electric Capacity 40 50 65 80 kVA 3.1 4.1 Sol. pump-1 kW 0.6 1.6 Sol. pump-2 kW 0.6 0.6 Ref. pump kW 0.6 0.6 Vac. pump kW 0.4 Length mm 1,577 2,276 2,275 2,843 3,851 Width mm 1,723 1,723 1,362 1,414 1,414 Height mm 1,691 1,691 2,228 2,258 2,258 Tube space mm 1,100 1,900 1,600 2,100 3,100 Operating weight Ton 1.6 1.6 2.4 2.5 2.9 3.7 3.8 4.9 Rigging weight Ton 1.4 1.4 2.2 2.2 2.6 3.3 3.4 4.4 Mot or Out put (50 Hz) Dim ensi on Insulation surface 1. 2. 3. 4. 5. Hot ㎡ 4 3.9 4.8 7.5 10 Cold ㎡ 2.5 4.7 5.8 6.2 8.2 1 usRT = 3.52kW(3,024kcal/h) Standard tube and waterside pressure(Chilled ,Hot and Cooling water circuit) : 8kgf/cm2(785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. SAB-HW Series SAB-HW Model Item Cooling Capacity Temperature Chill ed Wat er Coo ling Wat er Hot wat er 012G1 015G1 018G1 021G1 024G1 028G1 032G1 036G1 usRT 120 150 180 210 240 280 320 360 kW 422 527 633 738 844 985 1,125 1,265.9 Mcal/h 363 454 544 635 726 847 968 1089 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 72.6 90.7 108.9 127 145.2 169.3 193.5 217.7 Pressure drop kPa 96 85 96 87 90 83 85 57 Pipe size(DN) mm Temperature ℃ 100 125 150 Inlet 31 Outlet 36.5 Flow rate ㎥/h 156 196 235 274 313 365 417 469 Pressure drop kPa 88 70 82 67 70 72 66 127 Pipe size(DN) mm Temperature ℃ 150 200 Inlet 95 250 Outlet 80 Flow rate ㎥/h 34.2 42.8 51.3 59.9 68.5 79.9 91.3 102.7 Pressure drop kPa 63 62 69 45 46 39 43 42 Pipe size(DN) mm 80 kVA 4.1 6.3 10.0 11.3 Sol. Pump-1 kW 1.6 2.4 3.7 3.7 Sol. Pump-2 kW 0.6 1.6 2.0 2.0 Ref. Pump kW 0.6 0.6 1.6 2.0 Vac. Pump kW Length mm 3,851 3,878 4,829 5,058 5,036 Width mm 1,414 1,600 1,600 1,727 1,922 Height mm 2,258 2,244 2,244 2,530 3,250 Tube Space mm 3,100 3,100 4,100 4,100 4,100 Operating Weight Ton 5.1 6.2 6.4 7.7 7.9 9.9 10.0 11.9 Rigging Weight Ton 4.5 5.4 5.5 6.7 6.8 8.2 8.4 10.1 Hot ㎡ 10.0 10.0 12.5 13.5 14.8 Cold ㎡ 8.2 8.2 13.5 14.5 15.9 Electric Capacity Mot or Out put (50 Hz) Dim ensi on Insulation Surface 1. 2. 3. 4. 5. 100 125 0.4 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot and Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. SAB-HW Series SAB-HW Medel Item Cooling Capacity Temperature Chill ed Wate r Cooli ng Wate r Hot wate r 040G1 046G1 052G1 058G1 064G1 072G1 080G1 090G1 100G1 usRT 400 460 520 580 640 720 800 900 1000 kW 1,407 1,617 1,828 2,039 2,250 2,532 2,813 3,165 3,516 Mcal/h 1,210 1,391 1,572 1,754 1,935 2,177 2,419 2,722 3,024 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 241.9 278.2 314.5 350.8 387.1 435.5 483.8 544.3 604.8 Pressure drop kPa 105 107 116 108 59 56 72 94 97 Pipe size(DN) mm Temperature ℃ 200 250 Inlet 31 300 Outlet 36.5 Flow rate ㎥/h 521 600 678 756 834 938 1,043 1,173 1,303 Pressure drop kPa 82 92 85 91 142 154 45 59 59 Pipe size(DN) mm 250 Temperature ℃ 300 350 Inlet 95 400 Outlet 80 Flow rate ㎥/h 114.1 131.2 148.3 165.5 182.6 205.4 228.2 256.7 285.3 Pressure drop kPa 21 24 30 32 50 54 60 79 84 Pipe size(DN) mm Electric Capacity 150 200 kVA 16.4 19.5 22.1 26.6 Sol. Pump-1 kW 5.5 5.5 5.5 7.5 Sol. Pump-2 kW 3.7 5.5 5.5 5.5 Ref. Pump kW 2.0 2.0 3.7 3.7 Vac. Pump kW Length mm 5,843 6,689 7,445 7,816 8,387 Width mm 1,916 2,039 2,035 2,047 2,158 Height mm 3,250 3,353 3,358 3,358 3,489 Tube Space mm 4,900 5,600 6,300 6,600 7,000 Operating Weight Ton 14.9 15.1 21.3 21.7 25.4 25.8 27.5 29.2 31.1 Rigging Weight Ton 13.3 13.5 16.3 16.6 22.1 22.5 23.9 25.4 26.3 Moto r Outp ut (50H z) Dime nsion Insulation Surface 1. 2. 3. 4. 5. 0.4 Hot ㎡ 16.6 19.7 21.6 22.7 24.5 Cold ㎡ 18.2 22.0 24.6 25.9 27.5 1 usRT = 3.52kW(3,024kcal/h) Standard tube and waterside pressure(Chilled, Hot and Cooling water circuit) : 8kgf/cm2(785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. High Efficiency SAB-HW Series SAB-HW Model Item Cooling capacity Temperature Chill ed Wat er Coo ling Wat er Hot wat er 001G1 002G1 003G1 004G1 005G1 006G1 008G1 010G1 usRT 15 20 30 40 50 65 80 100 kW 53 70 105 141 176 229 281 352 Mcal/h 45 60 91 121 151 197 242 302 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 9.1 12.1 18.1 24.2 30.2 39.3 48.4 60.5 Pressure drop kPa 41 41 52 52 49 54 62 89 Pipe size(DN) mm 32 40 80 100 Temperature ℃ 50 65 Inlet 31 Outlet 36.5 Flow rate ㎥/h 18.6 24.7 37.1 49.5 61.9 80.4 99 123.7 Pressure drop kPa 45 46 41 46 58 72 81 75 Pipe size(DN) mm 65 80 Temperature ℃ 50 Inlet 95 100 125 Outlet 80 Flow rate ㎥/h 3.9 5.2 7.8 10.4 13.0 16.9 20.8 26.0 Pressure drop kPa 11 19 26 47 41 36 43 48 Pipe size(DN) mm 25 40 50 65 Electric Capacity kVA 3.1 4.1 Sol. Pump-1 kW 0.6 1.6 Sol. Pump-2 kW 0.6 0.6 Ref. Pump kW 0.6 0.6 Vac. Pump kW 0.4 0.4 Length mm 1,577 2,276 2,275 2,843 3,851 Width mm 1,723 1,723 1,362 1,414 1,414 Height mm 1,691 1,691 2,228 2,258 2,258 Tube Space mm 1,100 1,900 1,600 2,100 3,100 Operating Weight Ton 1.6 1.6 2.4 2.5 2.9 3.7 3.8 4.9 Rigging Weight Ton 1.4 1.4 2.2 2.2 2.6 3.3 3.4 4.4 Mot or Out put (50 Hz) Dim ensi on Insulation Surface 1. 2. 3. 4. 5. Hot ㎡ 4.0 5.0 4.8 7.5 10.0 Cold ㎡ 2.5 3.5 5.8 6.2 8.2 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot and Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. High Efficiency SAB-HW Series SAB-HW Model Item Cooling capacity Temperature Chill ed Wat er Coo ling Wat er Hot wat er 012G1 015G1 018G1 021G1 024G1 028G1 032G1 036G1 usRT 120 150 180 210 240 280 320 360 kW 422 527 633 738 844 985 1,125 1,266 Mcal/h 363 454 544 635 726 847 968 1,089 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 72.6 90.7 108.9 127.0 145.2 169.3 193.5 217.7 Pressure drop kPa 96 85 96 87 90 83 85 73 Pipe size(DN) mm Temperature ℃ 100 125 150 Inlet 31 Outlet 36.5 Flow rate ㎥/h 149 186 223 260 297 347 396 445 Pressure drop kPa 79 63 74 60 63 65 59 52 Pipe size(DN) mm 125 150 Temperature ℃ 200 Inlet 95 250 Outlet 80 Flow rate ㎥/h 31.2 39.0 46.8 54.6 62.5 72.9 83.3 93.7 Pressure drop kPa 56 55 61 40 40 35 38 43 Pipe size(DN) mm 80 100 125 Electric capacity kVA 4.1 6.3 10.0 11.3 Sol. Pump-1 kW 1.6 2.4 3.7 3.7 Sol. Pump-2 kW 0.6 1.6 2.0 2.0 Ref. Pump kW 0.6 0.6 1.6 2.0 Vac. Pump kW Length mm 3,851 3,878 4,829 5,058 4,984 Width mm 1,414 1,600 1,600 1,727 1,922 Height mm 2,258 2,244 2,244 2,530 3,250 Tube Space mm 3,100 3,100 4,100 4,100 4,100 Operating Weight Ton 5.1 6.2 6.4 7.7 7.9 9.9 10.0 11.9 Rigging Weight Ton 4.5 5.4 5.5 6.7 6.8 8.2 8.4 10.1 Hot ㎡ 10 10 12.5 13.5 14.8 Cold ㎡ 8.2 8.2 13.5 14.5 15.9 Mot or Out put (50 Hz) Dim ensi on Insulation Surface 1. 2. 3. 4. 5. 0.4 1 usRT = 3.52kW(3,024kcal/h) Standard tube and waterside pressure(Chilled, Hot and Cooling water circuit) : 8kgf/cm2(785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. High Efficiency SAB-HW Series SAB-HW Medel Item Cooling capacity Temperature Chill ed Wate r Cooli ng Wate r Hot wate r 040G1 045G1 050G1 060G1 070G1 080G1 090G1 1000G1 110G1 usRT 400 450 500 600 700 800 900 1,000 1,100 kW 1,407 1,582 1,758 2,110 2,461 2,813 3,165 3,516 3,868 Mcal/h 1,210 1,361 1,512 1,814 2,117 2,419 2,722 3,024 3,326 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 241.9 272.2 302.4 362.9 423.4 483.8 544.3 604.8 665.3 Pressure drop kPa 70 40 38 47 48 69 91 116 117 Pipe size(DN) mm Temperature ℃ 200 250 Inlet 31 300 Outlet 36.5 Flow rate ㎥/h 495 557 619 742 866 990 1,113 1,237 1,361 Pressure drop kPa 55 93 98 102 119 43 51 65 65 Pipe size(DN) mm Temperature ℃ 250 300 350 Inlet 95 400 Outlet 80 Flow rate ㎥/h 104.1 117.1 130.1 156.1 182.2 208.2 234.2 260.2 286.2 Pressure drop kPa 46 24 25 35 41 59 68 11 11 Pipe size(DN) mm 125 kVA 11.3 16.4 19.5 22.1 26.6 Sol. Pump-1 kW 3.7 5.5 5.5 5.5 7.5 Sol. Pump-2 kW 2.0 3.7 5.5 5.5 5.5 Ref. Pump kW 2.0 2.0 2.0 3.7 3.7 Vac. Pump kW Length mm 4,984 5,843 6,689 7,460 7,816 8,438 Width mm 1,922 1,916 2,039 2,035 2,047 2,158 Height mm 3,250 3,250 3,353 3,358 3,358 3,489 Tube Space mm 4,100 4,900 5,600 6,300 6,600 7,000 Operating Weight Ton 11.9 14.9 15.1 21.3 21.7 25.8 27.5 29.2 31.1 Rigging Weight Ton 10.1 13.3 13.5 16.3 16.6 22.5 23.9 24.5 25.4 Hot ㎡ 14.8 16.6 19.7 21.6 22.7 24.5 Cold ㎡ 15.9 18.2 22 24.6 25.9 27.2 Electric Capacity Moto r Outp ut (50H z) Dime nsion Insulatio n Surface 1. 2. 3. 4. 5. 150 200 200 0.4 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot and Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. Two Stage Hot Water driven Absorption Chiller CHP Solution Inc. HOT WATER OUTLET HOT WATER INLET COOLING WATER OUTLET CYCLE DIAGRAM FOR MW-G SERIES HOT WATER CONTROL VALVE T4 T5 T6 PURGE EJECTOR CHILLED WATER OUTLET T2 EVAP-L ABSO-L COND-H SAFETY VALVE GENE-H PURGE TANK 69WC EVAP-H COND-L ABSO-H GENE-L MANOMETER CHILLED WATER INLET T1 T9 P COMPOUND GUAGE PURGE SOLENOID VALVE T8 T9 GAS SEPARATOR MS VACUUM.PUMP LHX MR REF.PUMP MP SOL.PUMP 26RL T7 MS HHX SOL.PUMP MS SOL.PUMP MS : ANGLE VALVE SOL.PUMP : DIAPHRAGM VALVE : SAFETY VALVE : SHUT OFF VALVE COOLING WATER INLET : FLOAT VALVE : SERVICE VALVE T3 Two Stage Hot Water driven Absorption Chiller CHP Solution Inc. Specifications SAB-MW Series SAB-MW Model Item Cooling Capacity Temperature Chill ed Wat er Coo ling Wat er Hot wat er 005G0 006G0 008G0 010G0 012G0 015G0 018G0 021G0 usRT 50 65 80 100 120 150 180 210 kW 176 229 281 352 422 527 633 738 Mcal/h 151 197 242 302 363 454 544 635 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 30.2 39.3 48.4 60.5 72.6 90.7 108.9 127.0 Pressure drop kPa 65 66 89 91 85 102 102 106 Pipe size(DN) mm 65 Temperature ℃ 80 100 Inlet 31 125 150 Outlet 36.5 Flow rate ㎥/h 64.2 83.4 102.7 128.3 154.0 192.5 231.0 269.5 Pressure drop kPa 46 47 69 73 62 72 72 74 Pipe size(DN) mm 100 Temperature ℃ 125 150 Inlet 95 200 Outlet 68 Flow rate ㎥/h 7.7 10.0 12.3 15.4 18.4 23.1 27.7 32.3 Pressure drop kPa 40 43 39 42 34 42 61 66 Pipe size(DN) mm 40 Electric Capacity kVA 5.2 7.0 9.2 10.5 Sol. pump kW 0.55+0.55 0.8+0.8 1.1+1.1 1.5+1.5 Sol. SP. pump kW 0.4+0.4 0.55+0.55 0.8+0.8 0.6+0.6 Ref. pump kW 0.3 Vac. pump kW Length mm 2,650 2,650 2,750 3,450 Width mm 2,040 2,260 2,450 2,450 Height mm 2,480 2,550 2,700 2,700 Mot or Out put (50 Hz) Dim ensi on 50 65 0.4 0.6 0.4 Tube space mm Operating weight Ton 5.6 5.7 5.9 6.1 6.8 7.2 9.6 10.2 Rigging weight Ton 5.0 5.1 5.3 5.4 6.1 6.5 8.3 8.8 Insulation surface 1. 2. 3. 4. 2,100 2,800 Hot ㎡ 11.5 12.0 13.5 16.0 Cold ㎡ 9.5 9.9 11.2 13.1 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot, Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50Hzand The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. SAB-MW Series SAB-MW Model Item Cooling Capacity Temperature Chil led Wat er Coo ling Wat er Hot wat er 025G0 030G0 035G0 040G0 045G0 051G0 057G0 usRT 250 300 350 400 450 510 570 kW 879 1,055 1,231 1,407 1,582 1,793 2,004 Mcal/h 756 907 1,058 1,210 1,361 1,542 1,724 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 151.2 181.4 211.7 241.9 272.2 308.4 344.7 Pressure drop kPa 60 59 89 96 98 80 81 Pipe size(DN) mm Temperature ℃ 150 200 Inlet 31 Outlet 36.5 Flow rate ㎥/h 320.8 385.0 449.2 513.3 577.5 654.5 731.5 Pressure drop kPa 36 36 54 52 53 43 44 Pipe size(DN) mm 200 Temperature ℃ 250 300 Inlet 95 Outlet 68 Flow rate ㎥/h 38.4 46.1 53.8 61.5 69.2 78.4 87.6 Pressure drop kPa 29 29 44 44 44 37 37 Pipe size(DN) mm 80 Electric Capacity kVA 11.6 18.6 28.6 37.0 Sol. pump kW 1.5+1.5 2.4+2.4 3.7+3.7 4.5+4.5 Sol. SP. pump kW 0.6+0.6 1.2+1.2 2.4+2.4 3.7+3.7 Ref. pump kW 1.1 Vac. pump kW Length mm 4,150 4,650 4,700 5,700 Width mm 2,580 2,580 2,810 2,810 Height mm 2,850 2,850 3,000 3,000 Tube space mm 3,500 Operating weight Ton 15.0 16.0 17.0 17.9 19.0 28.2 30.4 Rigging weight Ton 12.6 13.4 14.3 15.2 16.2 24.9 26.6 Mot or Out put (50 Hz) Dim ensi on Insulation surface 1. 2. 3. 4. 100 125 1.5 0.4 4,000 5,000 Hot ㎡ 21.6 23.0 24.4 31.5 Cold ㎡ 23.2 24.7 26.2 35.2 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot , Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. Single Effect Double Lift Hot Water driven Absorption Chiller CHP Solution Inc. GENE-2 HOT WATER OUTLET HOT WATER INLET COOLING WATER OUTLET CYCLE DIAGRAM FOR LW-G SERIES T6 T5 T4 ABSO-A V20 COND CHILLED WATER OUTLET EVAP T2 GENE-3 PURGE EJECTOR SAFETY VALVE V21 ABSO PURGE TANK GENE-1 V24 T10 69WC MANOMETER CHILLED WATER INLET V22 P T1 V23 COMPOUND GUAGE V11 SOL.SP-2 PUMP MS V13 T9 V12 V17 V14 SOL.SP-1 PUMP AUX-2 PUMP MS T7 V3 V8 MS AUX-1 PUMP PURGE SOLENOID VALVE MS V18 V10 LIQUID SUPPLY V9 V19 V25 V16 V15 GAS SEPARATOR MP : FLOW SET VALVE T8 VACUUM.PUMP : ANGLE VALVE V7 26RL : SERVICE VALVE : DIAPHRAGM VALVE : SAFETY VALVE : SHUT OFF VALVE V2 MR REF.PUMP V1 V5 MS LHX HHX AHX V6 SOL.PUMP COOLING WATER INLET V4 : FLOAT VALVE T3 Single Effect Double Lift Hot Water driven Absorption Chiller CHP Solution Inc. Specifications SAB-LW Series SAB-LW Model Item Cooling Capacity Temperature Chil led Wat er Coo ling Wat er Hot wat er 006G1 008G1 010G1 012G1 015G1 018G1 021G1 024G1 usRT 65 80 100 120 150 180 210 240 kW 229 281 352 422 527 633 738 844 Mcal/h 197 242 302 363 454 544 635 726 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 39.3 48.4 60.5 72.6 90.7 108.9 127.0 145.2 Pressure drop kPa 77 81 73 73 68 76 71 72 Pipe size(DN) mm 65 80 Temperature ℃ 100 125 Inlet 31 150 Outlet 36.5 Flow rate ㎥/h 91.5 112.7 140.8 169.0 211.3 253.5 295.8 338.0 Pressure drop kPa 61 66 69 70 76 85 77 79 Pipe size(DN) mm 100 Temperature ℃ 125 150 Inlet 95 200 Outlet 55 Flow rate ㎥/h 7.9 9.7 12.1 14.5 18.1 21.8 25.4 29.0 Pressure drop kPa 43 48 54 58 50 55 63 62 Pipe size(DN) mm 40 50 kVA 4.0 8.6 9.8 10.2 Sol. pump kW 0.55 1.5 2.2 2.4 Ref. pump kW 0.3 Vac. pump kW Length mm 2,897 3,833 4,035 4,983 Width mm 2,084 2,084 2,250 2,250 Height mm 2,584 2,584 2,779 2,779 Tube space mm 2,100 Operating weight Ton 7.6 7.8 10.9 11.2 11.9 12.5 15.0 15.4 Rigging weight Ton 5.5 5.7 7.9 8.1 8.3 8.5 10.9 11.2 Electric Capacity Mot or Out put (50 Hz) Dim ensi on Insulatio n surface 1. 2. 3. 4. 5. 65 0.4 0.4 3,100 4,100 Hot ㎡ 10.3 15.5 19.5 Cold ㎡ 4.3 6.5 8.4 1 usRT = 3.52kW(3,024kcal/h) 2 Standard tube and waterside pressure(Chilled, Hot. Cooling water circuit) : 8kgf/cm (785kPa) Electrical data is based on 3ph/400V/50H, The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. SAB-LW Series SAB-LW Model Item Cooling Capacity Temperature Chil led Wat er Coo ling Wat er Hot wat er 028G1 032G1 036G1 040G1 046G1 052G1 058G1 064G1 usRT 280 320 360 400 460 520 580 640 kW 985 1,125 1,266 1,407 1,617 1,828 2,039 2,250 Mcal/h 847 968 1,089 1,210 1,391 1,572 1,754 1,935 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 169.3 193.5 217.7 241.9 278.2 314.5 350.8 387.1 Pressure drop kPa 69 102 61 81 117 114 154 64 Pipe size(DN) mm Temperature ℃ 150 200 Inlet 31 250 Outlet 36.5 Flow rate ㎥/h 394.4 450.7 507.0 563.4 647.9 732.4 816.9 901.4 Pressure drop kPa 81 111 71 93 132 96 129 73 Pipe size(DN) mm Temperature ℃ 250 300 Inlet 95 350 Outlet 55 Flow rate ㎥/h 33.9 38.7 43.5 48.4 55.6 62.9 70.2 77.4 Pressure drop kPa 58 65 60 54 65 60 62 59 Pipe size(DN) mm Electric Capacity Mot or Out put (50 Hz) 80 kVA 100 17.1 125 19.1 27.5 Sol. pump kW Ref. pump kW Vac. pump kW Length mm 5,051 4,719 5,164 5,443 6,043 6,013 6,593 7,376 Width mm 2,536 2,820 2,820 2,820 2,820 2,977 2,977 2,977 Height mm 2,960 3,222 3,222 3,243 3,243 3,467 3,467 3,517 Tube space mm 4,100 3,600 4,100 4,300 4,900 4,800 5,400 6,100 Operating weight Ton 18.1 18.9 21.3 22.0 24.5 25.0 27.7 31.3 Rigging weight Ton 12.6 13.4 15.3 15.5 17.5 17.7 19.8 22.2 Hot ㎡ 20.5 19.3 20.8 21.8 23.3 26.7 28.3 30.1 Cold ㎡ 9.8 9.4 10 10.6 11.3 13.4 14.2 15.3 Dim ensi on Insulation surface 1. 2. 3. 4. 5. 3.0 4.5 0.4 1.5 0.4 1 usRT = 3.52kW(3,024kcal/h) Standard tube and waterside pressure(Chilled, Hot, Cooling water circuit) : 8kgf/cm2(785kPa) Electrical data is based on 3ph/400V/50H. The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. SAB-LW Series SAB-LW Model Item Cooling Capacity Temperature Chil led Wat er Coo ling Wat er Hot wat er 072G1 080G1 090G1 100G1 115G1 130G1 usRT 720 800 900 1,000 1,150 1,300 kW 2,532 2,813 3,165 3,516 4,044 4,571 Mcal/h 2,177 2,419 2,722 3,024 3,478 3,931 Inlet 13 ℃ Outlet 8 Flow rate ㎥/h 435.5 483.8 544.3 604.8 695.5 786.2 Pressure drop kPa 87 64 87 114 91 125 Pipe size(DN) mm Temperature ℃ 250 300 Inlet 31 Outlet 36.5 Flow rate ㎥/h 1,014.1 1,126.7 1,267.6 1,408.4 1,619.7 1,830.9 Pressure drop kPa 98 68 91 118 100 136 Pipe size(DN) mm 350 Temperature ℃ 400 450 Inlet 95 500 Outlet 55 Flow rate ㎥/h 87.1 96.8 108.9 120.9 139.1 157.2 Pressure drop kPa 53 59 53 70 65 58 Pipe size(DN) mm Electric Capacity Mot or Out put (50 Hz) 125 kVA 150 27.5 29.3 Sol. pump kW 4.5 Ref. pump kW 1.5 Vac. pump kW 0.4 Length mm 7,856 7,551 8,031 8,561 8,540 8,975 Width mm 2,977 3,167 3,167 3,167 3,410 3,410 Height mm 3,517 3,745 3,745 3,745 3,810 3,810 Tube space mm 6,600 6,100 6,600 7,100 6,900 7,500 Operating weight Ton 33.9 39.5 42.5 45.8 46.5 49.5 Rigging weight Ton 24.0 29.0 31.3 33.8 34.0 36.5 Hot ㎡ 32.5 32.3 33.5 34.8 35.8 38.4 Cold ㎡ 16.5 16.2 17.5 18.2 19.5 20.9 Dim ensi on Insulation surface 1. 2. 3. 4. 1 usRT = 3.52kW(3,024kcal/h) Standard tube and waterside pressure(Chilled, Hot, Cooling water circuit) : 8kgf/cm2(785kPa) Electrical data is based on 3ph/400V/50Hz The specifications are subject to change without prior notice. For other than above this table, contact nearest Sales agent. CHP Solution Inc. Outline Dimension & Pipe connection size SAB-HW G Series HW001G1 to 004G1 Model HW001G1 HW002G1 HW003G1 HW004G1 Outline dimension(mm) L W H 1,577 1,723 1,691 1,577 1,723 1,691 2,276 1,723 1,691 2,276 1,723 1,691 A 32 40 50 50 Nozzle size(DN) B C D E 32 50 50 25 40 65 65 40 50 65 65 40 50 80 80 50 F 25 40 40 50 Tube space G 1,100 1,100 1,900 1,900 CHP Solution Inc. HW005G1 to 100G1 Model HW005G1 HW006G1 HW008G1 HW010G1 HW012G1 HW015G1 HW018G1 HW021G1 HW024G1 HW028G1 HW032G1 HW036G1 HW040G1 HW046G1 HW052G1 HW058G1 HW064G1 HW072G1 HW080G1 HW090G1 HW100G1 Outline dimension(mm) L W H 2,275 1,362 2,228 2,843 1,414 2,258 2,843 1,414 2,258 3,851 1,414 2,258 3,851 1,414 2,258 3,878 1,600 2,244 3,878 1,600 2,244 4,829 1,600 2,244 4,829 1,600 2,244 5,058 1,727 2,530 5,058 1,727 2,530 5,036 1,922 3,250 5,843 1,916 3,250 5,843 1,916 3,250 6,689 2,039 3,353 6,689 2,039 3,353 7,445 2,035 3,358 7,445 2,035 3,358 7,816 2,047 3,358 8,387 2,158 3,489 8,387 2,158 3,489 A 65 65 80 100 100 100 125 125 125 150 150 150 200 200 200 200 250 250 250 250 300 Nozzle size(DN) B C D E 65 100 100 50 65 100 100 65 80 125 125 65 100 125 125 80 100 150 150 80 100 150 150 100 125 200 200 100 125 200 200 100 125 200 200 100 150 200 200 125 150 200 200 125 150 250 250 125 200 250 250 150 200 300 300 150 200 300 300 150 200 300 300 200 250 300 300 200 250 350 350 200 250 350 350 200 250 400 400 200 300 400 400 200 F 50 65 65 80 80 100 100 100 100 125 125 125 150 150 150 200 200 200 200 200 200 Tube space G 1,600 2,100 2,100 3,100 3,100 3,100 3,100 4,100 4,100 4,100 4,100 4,100 4,900 4,900 5,600 5,600 6,300 6,300 6,600 7,000 7,000 CHP Solution Inc. SAB-MW G Series Model MW005G0 MW006G0 MW008G0 MW010G0 MW012G0 MW015G0 MW018G0 MW021G0 MW025G0 MW030G0 MW035G0 MW040G0 MW045G0 MW051G0 MW057G0 Outline dimension(mm) L W H 2,650 2,040 2,480 2,650 2,040 2,480 2,650 2,260 2,550 2,650 2,260 2,550 2,750 2,450 2,700 2,750 2,450 2,700 3,450 2,450 2,700 3,450 2,450 2,700 4,150 2,850 2,850 4,150 2,850 2,850 4,650 2,850 2,850 4,700 2,810 3,000 4,700 2,810 3,000 5,700 2,810 3,000 5,700 2,810 3,000 A 65 80 80 100 100 125 125 150 150 150 150 200 200 200 200 Nozzle size(DN) B C D E 65 100 100 40 80 125 125 40 80 125 125 50 100 150 150 65 100 150 150 65 125 200 200 65 125 200 200 65 150 200 200 65 150 200 200 80 150 250 250 80 150 250 250 100 200 300 300 100 200 300 300 100 200 300 300 100 200 300 300 125 F 40 40 50 65 65 65 65 65 80 80 100 100 100 100 125 Tube space G 2,100 2,100 2,100 2,100 2,100 2,100 2,800 2,800 3,500 3,500 4,000 4,000 4,000 5,000 5,000 CHP Solution Inc. SAB-LW G Series Model LW006G1 LW008G1 LW010G1 LW012G1 LW015G1 LW018G1 LW021G1 LW024G1 LW028G1 LW032G1 LW036G1 LW040G1 LW046G1 LW052G1 LW058G1 LW064G1 LW072G1 LW080G1 LW090G1 LW100G1 LW115G1 LW130G1 Outline dimension(mm) L W H 2,897 2,084 2,584 2,897 2,084 2,584 3,883 2,084 2,584 3,883 2,084 2,584 4,035 2,250 2,779 4,035 2,250 2,779 4,983 2,250 2,779 4,983 2,250 2,779 5,051 2,536 2,960 4,719 2,820 3,222 5,164 2,820 3,222 5,443 2,820 3,243 6,043 2,820 3,243 6,013 2,977 3,467 6,593 2,977 3,467 7,376 2,977 3,517 7,856 2,977 3,517 7,551 3,167 3,745 8,031 3,167 3,745 8,561 3,167 3,745 8,540 3,410 3,810 8,975 3,410 3,810 A 65 80 100 100 100 125 125 125 150 150 150 200 200 200 200 250 250 250 250 300 300 300 Nozzle size(DN) B C D E 65 100 100 40 80 125 125 40 100 125 125 50 100 150 150 50 100 150 150 65 125 200 200 65 125 200 200 65 125 200 200 80 150 250 250 80 150 250 250 80 150 250 250 80 200 250 250 100 200 300 300 100 200 300 300 100 200 300 300 125 250 350 350 125 250 350 350 125 250 400 400 125 250 400 400 125 300 450 450 125 300 450 450 150 300 500 500 150 F 40 40 50 50 65 65 65 80 80 80 80 100 100 100 125 125 125 125 125 125 150 150 Tube space G 2,100 2,100 3,100 3,100 3,100 3,100 4,100 4,100 4,100 3,600 4,100 4,300 4,900 4,800 5,400 6,100 6,600 6,100 6,600 7,100 6,900 7,500 CHP Solution Inc. Foundation SAB-HW G Series Model HW001,002G1 HW003,004G1 HW005G1 HW006,008G1 HW010,012G1 HW015,018G1 HW021,024G1 HW028,032G1 HW036G1 HW040,046G1 HW052,058G1 HW064,072G1 HW080G1 HW090,100G1 WEIGHT(Ton) AA 0.8 1.25 1.45 1.9 2.55 3.2 3.95 5.0 5.95 7.55 10.85 12.9 13.75 14.6 BB 0.8 1.25 1.45 1.9 2.55 3.2 3.95 5.0 5.95 7.55 10.85 12.9 13.75 14.6 A 950 1,740 1,357 1,830 2,818 2,818 3,732 3,682 3,650 4,450 5,120 5,870 6,176 6,576 B 475 870 678.5 915 1,409 1,409 1,866 1,841 1,825 2,225 2,560 2,935 3,088 3,288 C 655 655 532.5 532.5 532.5 602.5 602.5 655 683.5 683.5 752 752 752 802.5 DIMENSION(mm) D E F 1,310 180 100 1,310 180 100 1,065 305 225 1,065 330 250 1,065 330 250 1,205 330 250 1,205 330 250 1,310 380 300 1,367 480 400 1,367 480 400 1,504 480 400 1,504 480 400 1,504 480 400 1,605 480 400 G 1.230 1.230 985 985 985 1.125 1.125 1.230 1.287 1.424 1.424 1.424 1,424 1,525 H 140 140 265 290 290 290 290 340 440 440 440 440 440 440 J 1.270 1.270 1.025 1.025 1.025 1.165 1.165 1.270 1.327 1.327 1.464 1.464 1.464 1.565 CHP Solution Inc. SAB-MW G Series Model MW005G0 MW006G0 MW008G0 MW010G0 MW012G0 MW015G0 MW018G0 MW021G0 MW025G0 MW030G0 MW035G0 MW040G0 MW045G0 MW051G0 MW057G0 WEIGHT(Ton) AA 2.8 2.85 2.95 3.05 3.4 3.6 4.8 5.1 7.5 8.0 8.5 8.95 9.5 14.1 15.2 BB 2.8 2.85 2.95 3.05 3.4 3.6 4.8 5.1 7.5 8.0 8.5 8.95 9.5 14.1 15.2 A 1,832 1,832 1,832 1,832 1,782 1,782 2,482 2,482 3,226 3,226 3,682 3,676 3,676 4,676 4,676 B 916 916 916 916 891 891 1,241 1,241 1,613 1,613 1,841 1,838 1,838 2,338 2,338 C 750.5 750.5 857.5 857.5 990 990 990 990 1,052.5 1,052.5 1,052.5 1,170 1,170 1,170 1,170 DIMENSION(mm) D E F 1,501 330 250 1,501 330 250 1,715 330 250 1,715 330 250 1,980 380 300 1,980 380 300 1,980 380 300 1,980 380 300 2,105 380 300 2,105 380 300 2,105 380 300 2,340 380 300 2,340 380 300 2,340 380 300 2,340 380 300 G 1,421 1,421 1,635 1,635 1,900 1,900 1,900 1,900 2,025 2,025 2,025 2,260 2,260 2,260 2,260 H 290 290 290 290 340 340 340 340 340 340 340 340 340 340 340 J 1,461 1,461 1,675 1,675 1,940 1,940 1,940 1,940 2,065 2,065 2,065 2,300 2,300 2,300 2,300 CHP Solution Inc. SAB-LW G Series Model LW006G1 LW008G1 LW010G1 LW012G1 LW015G1 LW018G1 LW021G1 LW024G1 LW028G1 LW032G1 LW038G1 LW040G1 LW046G1 LW052G1 LW058G1 LW064G1 LW072G1 LW080G1 LW090G1 LW100G1 LW115G1 LW130G1 WEIGHT(Ton) AA 3.8 3.9 5.45 5.6 5.95 6.25 7.5 7.7 9.75 9.45 10.65 11.0 12.25 12.5 13.85 15.65 16.95 19.75 21.25 22.9 23.25 24.75 BB 3.8 3.9 5.45 5.6 5.95 6.25 7.5 7.7 9.75 9.45 10.65 11.0 12.25 12.5 13.85 15.65 16.95 19.75 21.25 22.9 23.25 24.75 A 1942 1942 2928 2928 2884 2884 3836 3836 3836 3310 3810 4010 4610 4500 5080 5800 6280 5806 6286 6816 6716 7316 B 971 971 1464 1464 1442 1442 1918 1918 1918 1655 1905 2005 2305 2250 2540 2900 3140 2903 3143 3408 3358 3658 C 832.5 832.5 832.5 832.5 954 954 954 954 991 1170 1170 1170 1170 1244 1244 1244 1244 1345 1345 1345 1521 1521 DIMENSION(mm) D E F 1665 330 250 1665 330 250 1665 330 250 1665 330 250 1908 380 300 1908 380 300 1908 380 300 1908 380 300 1982 380 300 2340 380 300 2340 380 300 2340 380 300 2340 380 300 2488 380 300 2488 380 300 2488 380 300 2488 380 300 2690 380 300 2690 380 300 2690 380 300 3042 380 300 3042 380 300 G 1575 1575 1575 1575 1828 1828 1828 1828 1902 2260 2260 2260 2260 2408 2408 2408 2408 2610 2610 2610 2962 2962 H 290 290 290 290 340 340 340 340 340 340 340 340 340 340 340 340 340 340 340 340 340 340 J 1615 1615 1615 1615 1868 1868 1868 1868 1942 2300 2300 2300 2300 2448 2448 2448 2448 2650 2650 2650 3002 3002 CHP Solution Inc. Thermal Insulation SAB-HW G Series Install the insulation that easy to joint and disjoint. THERMOMETER Minimum length for disjointing INSULATION 300 INSULATION INSULATION INSULATION INSULATION WATER BOX POCKET THERMOMETOR INSULATION GALVANIZED IRON VALVE INSULATION WATER BOX INSULATION REF. PUMP INSULATION GENERATOR EVAPORATOR Solution pipe HEAT EXCHANGER REF. PUMP Notes 1. Use the polyethylene form(Density is minimum 38kg/m ) or equivalent for insulation surface. 2. We recommend to use the 25~50mm polyethylene form. 3. Non-flammable material for insulation is recommended. 4. Use the bond, band, steel plate to stick, but you shouldn't use welding, pushpin and tapping. 5. It must be easy to disjoint and joint insulation in flange or external parts. CHP Solution Inc. SAB-MW G Series Install the insulation that easy to joint and disjoint. THERMOMETER Minimum length for disjointing INSULATION 300 INSULATION INSULATION INSULATION POCKET GALVANIZED IRON THERMOMETOR INSULATION EVAP INSULATION WATER BOX VALVE INSULATION REF. PUMP INSULATION WATER BOX INSULATION GENE-H GENE-L REF.PUMP & PIPE Notes 1. Use the polyethylene form(Density is minimum 38kg/m ) or equivalent for insulation surface. 2. We recommend to use the 25~50mm polyethylene form. 3. Material of insulation must be non-flammability. 4. Use the bond, band, steel plate to stick, but you shouldn't use welding, pushpin and tapping. 5. It must be easy to disjoint and joint insulation in flange or external parts. CHP Solution Inc. SAB-LW G Series Install the insulation that easy to joint and disjoint. THERMOMETER Minimum length for disjointing INSULATION 300 INSULATION INSULATION INSULATION INSULATION WATER BOX POCKET GALVANIZED IRON THERMOMETOR INSULATION VALVE INSULATION WATER BOX INSULATION REF. PUMP INSULATION 2nd GENE. AUX.GENE. 1st GENE. EVAP REF.PUMP & PIPE Notes 1. Use the polyethylene form(Density is minimum 38kg/m ) or equivalent for insulation surface. 2. We recommend to use the 25~50mm polyethylene form. 3. Material of insulation must be non-flammability. 4. Use the bond, band, steel plate to stick, but you shouldn't use welding, pushpin and tapping. 5. It must be easy to disjoint and joint insulation in flange or external parts. CHP Solution Inc. Electric Diagram SAB-HW G Series Schematic Diagram MCCB1 MCCB6 MCCB7 FUSE TR(380V/220V) N/F TR(220V/24V) TNR POL635 MCCB2 88P1 OCR1 POL965.00 MCCB3 88P2 OCR2 MCCB4 POL925.00 RX FX 11X 12X 13X 21X 22X 23X MCCB5 88P3 88P4 OCR3 OCR4 ** SYMBOL LISTS ** MARK DESCRIPTION MCCB1 MOLDED CASE CIRCUIT BREAKER(WITH E-HANDLE) MCCB2~5 MOLDED CASE CIRCUIT BREAKER FOR PUMP TR1 TRANSFORMER EF1 FUSE FOR TRANSFORMER 88P1 MAGNETIC CONTACTOR FOR SOLUTION PUMP OCR1 EOCR FOR SOLUTION PUMP OVER CURRENT 88P2 MAGNETIC CONTACTOR FOR SPRAY PUMP OCR2 EOCR FOR SPRAY PUMP OVER CURRENT 88P3 MAGNETIC CONTACTOR FOR REFRIGERANT PUMP OCR3 EOCR FOR REFRIGERANT PUMP OVER CURRENT 88P4 MAGNETIC CONTACTOR FOR PURGE PUMP OCR4 EOCR FOR PURGE PUMP ITH1~3 INTERNAL THERMOSTAT FOR MOTOR COIL CHP Solution Inc. ** SYMBOL LISTS ** MARK DESCRIPTION MARK DESCRIPTION MCCB6 MOLDED CASE CIRCUIT BREAKER EF2 FUSE FOR CONTROLLER MCCB7 MOLDED CASE CIRCUIT BREAKER NOISE FILTER NOISE FILTER EMG EMERGENCY SWITCH(PUSH LOCK & TURN RESET SWITCH) PBL2 ILLUMINATED PUSH BUTTON PBL ILLUMINATED PUSH BUTTON SWITCH RX CONTROL RELAY (CA2-KN-40-M7) X14~X21 AUXILIARY RELAY OCR4 OVER CURRENT RELAY FOR PURGE PUMP GL GREEN PILOT LAMP FOR SYSTEM RUN 88P3 MAGNETIC CONTACTOR FOR REFIGERANT PUMP TS ROTARY SWITCH FOR BUZZER ON/OFF 88P4 MAGNETIC CONTACTOR FOR PURGE PUMP 88P4 MAGNETIC COIL CONTACTOR FOR PUGE PUMP 23C THERMOSTAT FOR EXHAUST FAN YL YELLOW PILOT LAMP FOR ALARMS FAN EXHAUST FAN BZ PANEL BUZZER FOR ALARMS DPS POWER SUPPLY FOR TOUCH PANEL TOUCH PANEL 88P1 MAGNETIC CONTACTOR FOR SOLUTION PUMP HVAC CONTROLLER MAIN CONTROLLER 88P2 MAGNETIC CONTACTOR FOR SPRAY PUMP WIRING NUMBER & TERMINAL BLOCK OPERATION & DISPLAY DEVICE CONTROLLER INPUT/ OUTPUT WIRING SCHEMATIC POL902 POL635 POL965 POL925 CHP Solution Inc. SAB-MW G Series Schematic Diagram ** SYMBOL LISTS ** MARK DESCRIPTION MCCB1 MOLDED CASE CIRCUIT BREAKER(WITH E-HANDLE) MCCB2~7 MOLDED CASE CIRCUIT BREAKER FOR PUMPS MCCB8 MOLDED CASE CIRCUIT BREAKER FOR CONTROL POWER TR1 TRANSFORMER FOR AC220V TR2 TRANSFORMER FOR AC24V NF NOISE FILTER EF1 FUSE FOR TRANSFORMER 88P1~6 MAGNETIC CONTACTOR FOR PUMPS OCR1~6 OVER CURRENT RELAY FOR PUMPS ITH1~5 INTERNAL THERMOSTAT FOR MOTOR COIL CHP Solution Inc. ** SYMBOL LISTS ** MARK DESCRIPTION EMG EMERGENCY SWITCH(Push Rock & Turn Reset switch) CPX CONTROL POWER RELAY (CA2-KN-40-M7) PBS PUSH BUTTON SWITCH FOR CONTROL POWER GL GREEN PILOT LAMP FOR SYSTEM RUN PBL1,2 ILLUMINATED PUSH BUTTON FOR PURGE PUMP YL YELLOW PILOT LAMP FOR ALARM FAN EXHAUST FAN 88P6 MAGNETIC COIL CONTACTOR FOR PURGE PUMP 11X~13X AUXILIARY RELAY FOR PUMP & COOLING FAN START SIGNAL DPS DC POWER SUPPLY FOR DC24V BZ BUZZER FOR ALARM TS TOGGLE SWITCH FOR ALARM RX AUXILIARY RELAY FOR SYSTEM RUN FX AUXILIARY RELAY FOR ALARM 21X~23X AUXILIARY RELAY FOR REMOTE & INTERLOCK SIGNAL CONTROLLER INPUT/OUTPUT WIRING SCHEMATIC POL902 POL635.00 POL965 POL925 CHP Solution Inc. CONTROLLER INPUT/OUTPUT WIRING SCHEMATIC POL635.00 POL965 POL925 CHP Solution Inc. SAB-LW G Series Schematic Diagram ** SYMBOL LISTS ** MARK MCCB1 DESCRIPTION MOLDED CASE CIRCUIT BREAKER(WITH E-HANDLE) MCCB2~8 MOLDED CASE CIRCUIT BREAKER FOR PUMPS MCCB9 MOLDED CASE CIRCUIT BREAKER FOR CONTROL POWER TR1 TRANSFORMER FOR AC220V TR2 TRANSFORMER FOR AC24V NF NOISE FILTER EF1 FUSE FOR TRANSFORMER 88P1~7 MAGNETIC CONTACTOR FOR PUMPS OCR1~7 OVER CURRENT RELAY FOR PUMPS ITH1~6 INTERNAL THERMOSTAT FOR MOTOR COIL CHP Solution Inc. ** SYMBOL LISTS ** MARK DESCRIPTION EMG EMERGENCY SWITCH(Push Rock & Turn Reset switch) CPX CONTROL POWER RELAY (CA2-KN-40-M7) PBS PUSH BUTTON SWITCH FOR CONTROL POWER GL GREEN PILOT LAMP FOR SYSTEM RUN PBL1,2 ILLUMINATED PUSH BUTTON FOR PURGE PUMP YL YELLOW PILOT LAMP FOR ALARM FAN EXHAUST FAN 88P7 MAGNETIC COIL CONTACTOR FOR PURGE PUMP 11X~13X AUXILIARY RELAY FOR PUMP & COOLING FAN START SIGNAL DPS DC POWER SUPPLY FOR DC24V BZ BUZZER FOR ALARM TS TOGGLE SWITCH FOR ALARM RX AUXILIARY RELAY FOR SYSTEM RUN FX AUXILIARY RELAY FOR ALARM 21X~23X AUXILIARY RELAY FOR REMOTE & INTERLOCK SIGNAL CONTROLLER INPUT/OUTPUT WIRING SCHEMATIC POL902 POL635.00 POL965 POL925 CHP Solution Inc. CONTROLLER INPUT/OUTPUT WIRING SCHEMATIC POL635.00 POL965 POL925 CHP Solution Inc. Guide Specifications CHP Solution Inc. Specifications 1. Application scope This production specification is applied to Zephyrus Hot Water Driven Absorption Chiller. 2. Components and Materials 2.1 Lower Shell 2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 Evaporator shell plate : Plain carbon steel(SS400) Refrigerant Dispersion Tray : Stainless steel(STS316L) Absorber shell plate : Plain carbon steel(SS400) Absorbent Dispersion Tray : Stainless steel(STS316L) Eliminator : Cold rolled steel sheet(SPCC) 2.2 Upper Shell 2.2.1 Condenser Shell plate : Plain carbon steel(SS400) 2.2.2 2nd Generator Shell plate : : Plain carbon steel(SS400) 2.2.3 Eliminator :Dispersion tray : Plain carbon steel(SS400) 2.3 Tube 2.3.1 Evaporator : Copper, C1220T, Φ16 2.3.2 Absorber, Condenser Tube : Copper, C1220T, Φ16 2.3.3 Generator : Copper, C1220T, Φ16 or Φ19 2.4 Absorbent Heat Exchanger 2.4.1 Plate Type Absorbent Heat Exchanger 2.5 Pumps 2.5.1 Diluted Absorbent pump and spray pump with isolating valves 2.5.2 Refrigerant pump with isolating valves 2.5.3 Purge pump 2.6 Unit Controller 2.6.1 2.6.2 2.6.3 2.6.4 Model : PLC-Climatix series, Siemens Type : Micro Processor Control Display : Touch Screen LCD Communication Port : RS– 485, Mod-bus 2.7 Hot water control valve 2.7.1 3-Way type 2.7.2 Located at the Hot water Outlet 2.8 Safety Devices and Function 2.8.1 Chilled water differential pressure switch 2.8.2 Chilled water freeze protection 2.8.3 Generator absorbent high temperature 2.8.4 Driving hot water high temperature 2.8.5 Digital PID control 2.8.6 Optimum dilution operation 2.8.7 Customer support function 2.8.8 User communication function 2.8.9 Sequential operation of peripheral equipment 2.8.10 Remote RUN/STOP and remote temperature setting function 2.8.11 Crystallization prevention function 2.8.12 Maximum input control 2.8.13 Sensor burn - out detection function 2.8.14 Set point auto limiting function CHP Solution Inc. 2.8.15 Absorbent pump operation / Stop control 2.8.16 Refrigeration pump operation / Stop control 2.8.17 Hot water control valve open / close Control 2.8.18 Operation data storage function 2.8.19 Fault data storage function 2.8.20 Operation time storage function 2.9 Locally mounted controls and Instruments 2.9.1 2.9.2 2.9.3 2.9.4 Chilled water differential pressure switch Thermostat for absorbent and spray pump Thermostat for refrigerant pump Over-current protections for absorbent, spray, refrigerant and purge pump. 2.10 Temperature sensors for followings; 2.10.1 Chilled water inlet / outlet 2.10.2 Cooling water inlet / outlet 2.10.3 Hot water inlet / outlet 2.10.4 Evaporator refrigerant 2.10.5 Condensed refrigerant 2.10.6 Generator absorbent 2.11 Purge Unit 2.11.1 Storage tank 2.11.2 Ejector device 2.11.3 Liquid / gas separator 2.11.4 Diaphragm valves 2.11.5 Pressure gauge for vacuum 2.11.6 Manometer 2.11.7 Piping & various manual valves 2.12 Interconnecting Piping And Wiring 2.12.1 Refrigerant and absorbent piping 2.12.2 Automatic de-crystallization circuit 2.12.3 Internal power and control wiring 2.13 Initial charges 2.13.1 Refrigerant : Distilled water (H2O) 2.13.2 Absorbent : Lithium bromide (LiBr 53 wt%) 2.13.3 Inhibitor : Lithium molybdate (LiNo3) 2.13.4 Alcohol : N-Octyl 2.14 Pressure 2.14.1 Working pressure of chilled & cooling water side : 8barg / 0.8MPa / 116 psig 2.14.2 Design pressure of chilled & cooling water side : 9.2barg / 0.92MPa / 134 psig 2.14.3 Test pressure of chilled & cooling water side : 13.8barg / 1.38MPa / 200 psig 2.15 Standard spares 2.15.1 O & M Manual : 1 Copy 2.15.2 Tools set : 1set 3. Painting Color 3.1 Body : Munsell No. 3.2PB 3.3/4.0 3.2 Controller : Yellow gray 3.3 It can be changed if customer request. 4. Thermal Insulation (Option) 4.1 Hot Surface : Non-inflammable polymer sponge 4.2 Cool Surface : Non-inflammable polymer sponge CHP Solution Inc. 5. Capacity Control The capacity is adjusted between 25%~100% of the load by the leaving chilled water temp. 6. Factory Testing Following test shall be carried out during the manufacturing; 6.1 Check of external dimensions 6.2 Hydraulic pressure test for water headers 6.3 Electric insulation resistance test 6.4 Leak test of vacuum sides 6.5 Safety device function test 6.6 Performance test (Option) 7. Scope of Limits The scope of supplier shall limit the followings; Inlet/Outlet flanges of evaporator water boxes Inlet flange of absorber water boxes Outlet flange of condenser water boxes Inlet flanges of gas connections The following scopes shall be supplied by the Buyer; 7.5.1 Unloading, unpacking & wasted materials management. 7.5.2 Any transportation not specified in the contract condition. 7.5.3 Sectional joining works between semi-knocked down parts and insulation work at job site. 7.5.4 Building & foundations. 7.5.5 Supply of utilities including electricity, waters and any other driving energy at rated conditions. 7.5.6 External wiring & piping for the Chiller. 7.5.7 Insulation for the chiller including necessary parts. 7.5.8 Cooling tower, chilled water pumps and cooling water pumps 7.5.9 Matching flanges, gasket, bolts and nuts 7.5.10 In/out nozzle flanges of chilled Water side 7.5.11 In/out nozzle flanges of cooling Water side 7.5.12 In/out nozzle flanges of hot water side 7.5.13 Cooling water inlet temp. control devices 7.5.14 Necessary tools, workers and materials for site test, if necessary 7.5.15 Any other item not specially mentioned in the supplier’s scope of supply 7.1 7.2 7.3 7.4 7.5 8. Site Test (Option) Performance trials will be carried out commissioning of the chiller under the available load. In case the load or rated utilities are not available, the chiller shall be deemed as handed over after the performance trials on the any available parameter. 9. Performance Criteria at site (Option) Performance trails of the Chiller shall be carried out to demonstrate the capacity of the Chiller. The following inputs to be provided by the Buyer; Steady Load(cooling load for the room) Input Parameters 9.1 Chilled water inlet temperature is not below the rated temperature. 9.2 Chilled water and cooling water as per the specification mentioned. 9.3 Water flow rate; Chilled water flow rate within +/- 5% Cooling water flow rate within + 5%, - 0% of the nominal flow rate CHP Solution Inc. CHP Solution Korea Co.,Ltd. http://www.centioncorp.com For continual development,, CHP Solution Inc. reserves the right to change specifications without notice Copyright © 2013 CHP Solution Inc. All rights reserved.
Similar documents
With Individual Map Images
Services: Air, Office, Phone, Water Fuels: ULS Diesel #2, Off Road Diesel #2, Biodiesel B20, Unleaded,
More informationThe Orroroo Masters Games Newsletter Saturdays news Netball News
Silver Medal: Peter Finn, Kym Fromm Bronze Medal: M McAuley, A Ireland 130+ Combined Age Group Gold Medal: W Dunkley, L Fuller Silver Medal: P Johns, J Arthur Bronze Medal: Kate Williams, J Liebich
More information