INSPECTION REPORT 1234 MAIN ST
Transcription
INSPECTION REPORT 1234 MAIN ST
INSPECTION REPORT For the Property at: 1234 MAIN ST SARASOTA, FL 34291 Prepared for: JOHN SMITH Inspection Date: Friday, June 14, 2013 Prepared by: greg arvin Arvin Home Inspections 4933 Bookelia Circle, Suite Bradenton Florida, FL 34203 941-586-4856 [email protected] arvinhomeinspections.com The best home inspection experience available. July 30, 2013 Dear John Smith, RE: Report No. 1007 1234 Main St Sarasota, FL 34291 Thanks very much for choosing us to perform your home inspection. The inspection itself and the attached report comply with the requirements of the Standards of Practice of our national Association. This document defines the scope of a home inspection. Clients sometimes assume that a home inspection will include many things that are beyond the scope. We encourage you to read the Standards of Practice so that you clearly understand what things are included in the home inspection and report. The report has been prepared for the exclusive use of our client. No use by third parties is intended. We will not be responsible to any parties for the contents of the report, other than the party named herein . The report is effectively a snapshot of the house, recording the conditions on a given date and time. Home inspectors cannot predict future behavior, and as such, we cannot be responsible for things that occur after the inspection. If conditions change, we are available to revisit the property and update our report. The report itself is copyrighted, and may not be used in whole or in part without our express written permission. Again, thanks very much for choosing us to perform your home inspection. Sincerely, greg arvin on behalf of Arvin Home Inspections Arvin Home Inspections 4933 Bookelia Circle, Suite Bradenton Florida, FL 34203 941-586-4856 [email protected] arvinhomeinspections.com Report No. 1007 SUMMARY 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR This Summary outlines potentially significant issues from a cost or safety standpoint. This section is provided as a courtesy and cannot be considered a substitute for reading the entire report. Please read the complete document. 1) tile floor in kitchen,cracked needs to be fixed. 2) door by garage weather seal,scratched by cat,fix 3)this home is in satisfactory condition, 4) good home Priority Maintenance Items This concludes the Summary section. The remainder of the report describes each of the home's systems and also details any recommendations we have for improvements. Limitations that restricted our inspection are included as well. The suggested time frames for completing recommendations are based on the limited information available during a pre-purchase home inspection. These may have to be adjusted based on the findings of specialists. Home Improvement - ballpark costs Providing great home inspections for every client every time Page 1 of 61 Report No. 1007 ROOFING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: roof is in satisfactory condition 1. Sloped roofing material: Composition shingles satisfactory 2. Composition shingles Providing great home inspections for every client every time Page 2 of 61 Report No. 1007 ROOFING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Probability of leakage: Low 3. Low Limitations Inspection performed: With binoculars from the ground From roof edge Recommendations General 1. satisfactory 4. Providing great home inspections for every client every time Page 3 of 61 Report No. 1007 ROOFING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR SLOPED ROOFING \ Composition shingles 2. Condition: satisfctory SLOPED ROOF FLASHINGS \ Flashings 3. Condition: Inspect during annual tune-up. SLOPED ROOF FLASHINGS \ Roof/wall flashings 4. Condition: satisfactory SLOPED ROOF FLASHINGS \ Pipe/stack flashings 5. Condition: good 5. satisfactory SLOPED ROOF FLASHINGS \ Drip edge flashings 6. Condition: satisfactory Providing great home inspections for every client every time Page 4 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: clean and neat 6. 7. Gutter & downspout material: Aluminum 8. Aluminum Gutter & downspout type: Eave mounted Providing great home inspections for every client every time Page 5 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 9. Eave mounted Gutter & downspout discharge: Downspout discharge: Lot slope: Above grade Above grade Away from house Wall surfaces - masonry: Block 10. Block with stucco Providing great home inspections for every client every time Page 6 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Wall surfaces : Stucco 11. Stucco Soffit and fascia: Aluminum 12. Aluminum Vinyl Driveway: Concrete Providing great home inspections for every client every time Page 7 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 13. Concrete Walkway: Concrete 14. Concrete Porch: Concrete Garage: General clean and neat Providing great home inspections for every client every time Page 8 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 15. General Limitations General: no limitations Recommendations ROOF DRAINAGE \ Gutters 7. Condition: satisfactury 16. Providing great home inspections for every client every time Page 9 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. ROOF DRAINAGE \ Downspouts 8. Condition: Clogged Implication(s): Chance of water damage to contents, finishes and/or structure Location: Front Right Side First Floor Task: Clean Time: When necessary 17. Clogged Providing great home inspections for every client every time Page 10 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. Click on image to enlarge. 9. Condition: Downspouts end too close to building Implication(s): Chance of water damage to contents, finishes and/or structure Location: Various Front First Floor Task: Clean Time: Discretionary Providing great home inspections for every client every time Page 11 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 18. Downspouts end too close to building WALLS \ Soffits and fascia 10. Condition: satisfactury 19. WALLS \ Flashings and caulking 11. Condition: satisfactory EXTERIOR GLASS \ General 12. Condition: satisfactory Providing great home inspections for every client every time Page 12 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 20. EXTERIOR GLASS \ Glass (glazing) 13. Condition: satisfactory EXTERIOR GLASS \ Frames 14. Condition: satisfactory 15. Condition: satisfactory DOORS \ General 16. Condition: satisfactory 21. Providing great home inspections for every client every time Page 13 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR LANDSCAPING \ Driveway 17. Condition: satisfactory LANDSCAPING \ Walkway 18. Condition: satisfactory 22. LANDSCAPING \ General 19. Condition: Trees or shrubs too close to house Implication(s): Chance of water damage to contents, finishes and/or structure | Chance of pests entering house | Material deterioration Location: Various First Floor Task: Monitor Time: Unpredictable Providing great home inspections for every client every time Page 14 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. SUMMARY 23. Trees or shrubs too close to house GARAGE \ General 20. Condition: satisfactory Providing great home inspections for every client every time Page 15 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 24. GARAGE \ Floor 21. Condition: Cracked Implication(s): Uneven floors Location: Front Left Side Task: Inspect annually Time: Discretionary 25. Cracked Providing great home inspections for every client every time Page 16 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR GARAGE \ Walls and ceilings 22. Condition: satisfactory 26. GARAGE \ Man-door into garage 23. Condition: Weatherstripping missing or ineffective Implication(s): Hazardous combustion products entering home Location: First Floor Garage Task: Repair Time: Discretionary 27. Weatherstripping missing or ineffective Providing great home inspections for every client every time Page 17 of 61 Report No. 1007 EXTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR GARAGE \ Vehicle doors 24. Condition: satisfactory 28. GARAGE \ Vehicle door operators 25. Condition: satisfactory 29. Providing great home inspections for every client every time Page 18 of 61 Report No. 1007 STRUCTURE 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Configuration: Slab-on-grade Foundation material: Floor construction: Poured concrete Concrete Exterior wall construction: Masonry 30. Masonry Roof and ceiling framing: Trusses satisfactory 31. Trusses OSB (Oriented Strand Board) sheathing Providing great home inspections for every client every time Page 19 of 61 Report No. 1007 STRUCTURE 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 32. OSB (Oriented Strand Board) sheathing Limitations Attic/roof space: Entered but access was limited 33. Entered but access was limited Providing great home inspections for every client every time Page 20 of 61 Report No. 1007 STRUCTURE 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Recommendations General 26. this home as a whole is satisfactory Providing great home inspections for every client every time Page 21 of 61 Report No. 1007 ELECTRICAL 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactury Service entrance cable and location: Overhead - cable type not determined 34. Overhead - cable type not determined Service size: 200 Amps (240 Volts) 35. 200 Amps (240 Volts) Providing great home inspections for every client every time Page 22 of 61 Report No. 1007 ELECTRICAL 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Main disconnect/service box rating: 200 Amps 36. 200 Amps Main disconnect/service box type and location: Breakers - garage 37. Breakers - garage Number of circuits installed: 28 System grounding material and type: Copper - Ufer Providing great home inspections for every client every time Page 23 of 61 Report No. 1007 ELECTRICAL 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Distribution panel rating: 200 Amps 38. 200 Amps Distribution panel type and location: Breakers - garage 39. Breakers - garage Distribution wire material and type: Copper - non-metallic sheathed Type and number of outlets (receptacles): Grounded - typical Providing great home inspections for every client every time Page 24 of 61 Report No. 1007 ELECTRICAL 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Circuit interrupters: Ground Fault (GFCI) & Arc Fault (AFCI): GFCI - garage GFCI - bathroom and exterior 40. GFCI - bathroom and exterior Smoke detectors: Present 41. Present Providing great home inspections for every client every time Page 25 of 61 Report No. 1007 ELECTRICAL 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Limitations Panel covers: satisfactory 42. Panel or disconnect cover: satisfactory 43. Providing great home inspections for every client every time Page 26 of 61 Report No. 1007 HEATING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Fuel/energy source: System type: Electricity Heat pump Furnace manufacturer: Trane 44. Trane Heat distribution: Ducts and registers Approximate capacity: Approximate age: 15 kW 7 years Typical life expectancy: Failure probability: Combination heating system 5 to 10 years Low Main fuel shut off at: Garage Chimney/vent: None Chimney liner: Not required Limitations General: to hot outside to do heating air check Inspection prevented/limited by: A/C or heat pump operating Providing great home inspections for every client every time Page 27 of 61 Report No. 1007 HEATING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL Safety devices: Not tested as part of a home inspection Warm weather: Prevented testing in heating mode Air conditioner or heat pump: Heat loss calculations: HEATING COOLING INSULATION PLUMBING INTERIOR Operating in cooling mode prevented test of heating system Not done as part of a home inspection Data plate on equipment: satisfactory Model number: 2tec3f36a1000ap Serial number: 5413pik2v 45. Recommendations General 27. satisfactory 28. satisfactory check out by veteran air license,cac1816468 Providing great home inspections for every client every time Page 28 of 61 Report No. 1007 COOLING & HEAT PUMP 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactory Model number: 2twr3036a1000aa Serial number: 63914f64f 46. Air conditioning type: Heat pump type: Air cooled Air source Manufacturer: Trane satisfactory 47. Trane 48. Trane Providing great home inspections for every client every time Page 29 of 61 Report No. 1007 COOLING & HEAT PUMP 1234 Main St, Sarasota, FL SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE Cooling capacity: 3 Tons Compressor type: Electric Compressor approximate age: Typical life expectancy: Failure probability: [email protected] June 14, 2013 ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 7 years 10 to 15 years Low Supply temperature: 70° Return temperature: 85° Temperature difference: 15° This suggests good performance. Limitations General: satisfactory Heat gain calculations: Not done as part of a home inspection Heat pump only tested in: Cooling mode Recommendations General 29. satisfactory, serviced by veteran air,license# cac1816468 49. Providing great home inspections for every client every time Page 30 of 61 Report No. 1007 INSULATION AND VENTILATION 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactory Attic/roof insulation material: Glass fiber Attic/roof insulation amount/value: R-32 Attic/roof ventilation: Soffit vent satisfactory 50. Soffit vent Ridge vent Attic/roof air/vapor barrier: Wall insulation material: Not determined Not determined Wall insulation amount/value: Wall air/vapor barrier: Not determined Not determined Floor above porch/garage insulation material: Not determined Floor above porch/garage insulation amount/value: Floor above porch/garage air/vapor barrier: Spot checked only None found None found Not determined Limitations General: no access Providing great home inspections for every client every time Page 31 of 61 Report No. 1007 INSULATION AND VENTILATION 1234 Main St, Sarasota, FL SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE Attic inspection performed: Air/vapor barrier system: [email protected] June 14, 2013 ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR By entering attic, but access was limited Continuity not verified Recommendations General 30. satisfactory ATTIC/ROOF \ Insulation 31. Condition: satisfactory ATTIC/ROOF \ Hatch 32. Condition: satisfactory Providing great home inspections for every client every time Page 32 of 61 Report No. 1007 PLUMBING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactory Water supply source: Private Service piping into building: Not visible 51. Not visible Supply piping in building: Plastic Main water shut off valve at the: Water flow and pressure: Functional Water heater fuel/energy source: Water heater type: Exterior wall Electric Conventional Water heater manufacturer: Rheem Providing great home inspections for every client every time Page 33 of 61 Report No. 1007 PLUMBING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 52. Rheem Tank capacity: 30 gallons Water heater approximate age: Typical life expectancy: 7 years 8 to 12 years Water heater failure probability: Waste piping in building: Floor drain location: Medium Not visible None found Limitations General: satisfactory Items excluded from a home inspection: shut-off valve Concealed plumbing Well Water quality Water treatment equipment Septic system Isolating/relief valves & main Water heater relief valves are not tested Recommendations RECOMMENDATIONS \ Overview 33. Condition: No plumbing recommendations are offered as a result of this inspection. WATER HEATER \ Life expectancy 34. Condition: Low failure probability Providing great home inspections for every client every time Page 34 of 61 Report No. 1007 PLUMBING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 53. Low failure probability WATER HEATER \ Tank 35. Condition: satisfactory WATER HEATER \ Hot/cold piping 36. Condition: Polybutylene at water heater Implication(s): Chance of water damage to contents, finishes and/or structure WATER HEATER \ Temperature/pressure relief valve 37. Condition: Shut off valve present Implication(s): Steam explosion WATER HEATER \ Drain valve 38. Condition: satisfactory 54. Providing great home inspections for every client every time Page 35 of 61 Report No. 1007 PLUMBING 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR WATER HEATER \ Location 39. Condition: satisfactory WATER HEATER - ELECTRIC \ Thermostats 40. Condition: satisfactory Providing great home inspections for every client every time Page 36 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactory Major floor finishes: Major wall finishes: Carpet Ceramic Gypsum board Major ceiling finishes: Stucco/texture/stipple Windows: Single/double hung 55. Single/double hung Aluminum Glazing: Single Exterior doors - type/material: Metal Garage door - metal Doors: Inspected Providing great home inspections for every client every time Page 37 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 56. Inspected Oven type: Conventional 57. Conventional Oven fuel: Electricity Appliances: Refrigerator Providing great home inspections for every client every time Page 38 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 58. Refrigerator Range hood 59. Range hood Dishwasher Providing great home inspections for every client every time Page 39 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 60. Dishwasher Door bell Laundry facilities: Washer 61. Washer Dryer Providing great home inspections for every client every time Page 40 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 62. Dryer Kitchen ventilation : Exhaust fan Recirculating type Bathroom ventilation : Exhaust fan 63. Exhaust fan Inventory Dishwasher: Whirlpool Inventory Water Heater: Rheem Providing great home inspections for every client every time Page 41 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Recommendations FLOORS \ General 41. Condition: satisfactory Click on image to enlarge. FLOORS \ Ceramic tile, stone, marble, etc 42. Condition: Tiles cracked kitchen floor area Implication(s): Cosmetic defects | Trip or fall hazard Location: First Floor Kitchen Task: Monitor Time: Discretionary 64. Tiles cracked 65. Tiles cracked Providing great home inspections for every client every time Page 42 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR FLOORS \ Carpet on floors 43. Condition: satisfactory Click on image to enlarge. Click on image to enlarge. FLOORS \ Concrete floors 44. Condition: Cracked basic stress crackes Implication(s): Cosmetic defects | Trip or fall hazard | Difficult access Location: First Floor Garage Task: Monitor Providing great home inspections for every client every time Page 43 of 61 Report No. 1007 INTERIOR 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 66. Cracked Providing great home inspections for every client every time Page 44 of 61 Report No. 1007 KITCHEN 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: satisfactory 67. Counter Type: Formica satisfactory 68. Formica Providing great home inspections for every client every time Page 45 of 61 Report No. 1007 KITCHEN 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Range/ Cooktop: Electric satisfactory 69. Electric Number of Ovens: 1 Hood/ Fan: Appears Functional satisfactory 70. Appears Functional Providing great home inspections for every client every time Page 46 of 61 Report No. 1007 KITCHEN 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Dishwasher: Appears Functional satisfactory 71. Appears Functional Garbage Disposal: Not Applicable Plumbing: Appears Functional satisfactory 72. Appears Functional Providing great home inspections for every client every time Page 47 of 61 Report No. 1007 KITCHEN 1234 Main St, Sarasota, FL SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE Misc. Appliance: [email protected] June 14, 2013 ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR No built-in Microwave Limitations General: satisfactory Providing great home inspections for every client every time Page 48 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: master bath 73. master bath General: halfbath Floors: half bath same Floors: master 74. tile,master Providing great home inspections for every client every time Page 49 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE Doors: [email protected] June 14, 2013 ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR half bath same Doors: hollow core wood hollow core wood six panel 75. hollow core wood Windows: half bath same Windows: alum 76. alum single pane Providing great home inspections for every client every time Page 50 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE Electrical: half bath same Electrical: GFCI Counter: half bath same Counter: laminate [email protected] June 14, 2013 ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Cabinet: pre-fabricated 77. pre-fabricated Sink/Basin: single bowl 78. single bowl half bath Providing great home inspections for every client every time Page 51 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Sink/Basin: ceramic double bowl 79. ceramic Tub: fiberglass fiberglass 80. fiberglass half bath soaker Providing great home inspections for every client every time Page 52 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 81. soaker jetted Shower: stall 82. stall tub/shower combo half bath Providing great home inspections for every client every time Page 53 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 83. tub/shower combo pre-fabricated 84. pre-fabricated Toilet: half bath same Toilet: standard Providing great home inspections for every client every time Page 54 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 85. standard half bath standard 86. standard Heat source: half bath same Heat source: register Providing great home inspections for every client every time Page 55 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 87. register Ventilation: half bath same Ventilation: fan 88. fan Providing great home inspections for every client every time Page 56 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Limitations General: satisfactory 89. satisfactory Services shut off: water 90. water Providing great home inspections for every client every time Page 57 of 61 Report No. 1007 BATHROOM 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Recommendations General 45. none Providing great home inspections for every client every time Page 58 of 61 Report No. 1007 SITE INFO 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description Weather: Sunny Clear Approximate temperature: 80° Attendees: Buyer’s Agent Buyer Seller Access to home provided by: Occupancy: Utilities: Seller The home was occupied at the time of the inspection. All utilities were on during the inspection. Approximate inspection Start time: Approximate inspection End time: Approximate age of home: Approximate size of home: Building type: The inspection started at 1:00 p.m. The inspection ended at 3:00 p.m. 5 year Approximate date of construction: 2008 1900 ft.² Ranch style Number of dwelling units: Number of stories: One Number of rooms: Six Single-family Number of bedrooms: Three Number of bathrooms: Two Number of kitchens: Below grade area: One Slab-on-grade Garage, carport and outbuildings: Area: Seller's representative Attached two-car garage Suburb Street type: Residential Providing great home inspections for every client every time Page 59 of 61 Report No. 1007 SITE INFO 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR 91. Residential Street surface: Paved END OF REPORT Providing great home inspections for every client every time Page 60 of 61 Report No. 1007 REFERENCE LIBRARY 1234 Main St, Sarasota, FL [email protected] June 14, 2013 SUMMARY ROOFING EXTERIOR STRUCTURE KITCHEN BATHROOM SITE INFO REFERENCE ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR The links below connect you to a series of documents that will help you understand your home and how it works. These are in addition to links attached to specific items in the report. Click on any link to read about that system. 01. ROOFING, FLASHINGS AND CHIMNEYS 02. EXTERIOR 03. STRUCTURE 04. ELECTRICAL 05. HEATING 06. COOLING/HEAT PUMPS 07. INSULATION 08. PLUMBING 09. INTERIOR 10. APPLIANCES 11. LIFE CYCLES AND COSTS 12. SUPPLEMENTARY Asbestos Radon Urea Formaldehyde Foam Insulation (UFFI) Lead Carbon Monoxide Mold Household Pests Termites and Carpenter Ants 13. HOME SET-UP AND MAINTENANCE 14. MORE ABOUT HOME INSPECTIONS Providing great home inspections for every client every time Page 61 of 61