dynascope - Fukuda Denshi
Transcription
dynascope - Fukuda Denshi
DD S - 7 0Y0 0 NS E R I AE S MSO N I TCO R I NOG S PY S T EEM W M T S T E L E M E T R Y T R A N S M I T T E R L X - 7 2 3 0 N The LX-7230N is a state-of-the-art patient worn telemetry transmitter featuring a "Quick View" LCD display screen that allows for immediate "Point of Care" visual confirmation of everything from electrode status to battery strength. strength Nellcor® Pulse Oximetry Pacemaker Detection ECG / SpO2 Waveforms & Numerics Lightweight Design (7 oz) Patient Event Button 2.5 Days of Continuous Operation on Two AA Batteries 3, 4 or 5 Lead ECG Cables IPX8 Waterproof LX-7230N Specifications Standard Specification ECG Size 72.0mm (W) x 98.0mm (H) x 24.8mm (D) (2.8" (W) x 3.8" (H) x 1.0" (D)) Numbers of Lead Electrode 3 / 4 / 5-electrode Weight APX. 190 grams (6.7 oz) Numbers of Input Channel 1 CH or 2 CH Transmitting Waveform ECG 1CH or 2CH, Respiration waveform, pulse waveform Accuracy of Sensitivity 10 mm / 1 mV ± 20 % ECG Lead Cable Type 3-electrode, 4-electrode, or 5-electrode lead cable HR, RR, PR, SpO2 value ECG Input Impedance 5M Transmitting Status Data Electrode Off, Low Battery, Event Switch, Pacemaker Detection, Channel ID, 64group Codes, SpO2 Sensor Off Maximum Input Voltage ± 5 mV and above Less than 10 mVp-p (95 dB and above) LCD Built-in Common Mode Rejection Ratio Waterproof IPX8 Accuracy of Heart Rate Measurement ± 10 % or ± 5 bpm, whichever is greater Battery Supply Two 1.5 V "AA" size Continuous Operating Time HR Display Range 0, 12 to 300 bpm APX. 2.5 days Frequency Characteristic 0.5 to 40 Hz (within -3 dB) Time Constant 0.4 sec. ± 25 % Pacemaker Pulse Detection / Rejection Comply with ANSI/AAMI EC13 Pacemaker pulse rejection capability Defibrillation Protection Yes / Meets the requirements of IEC60601-2-27 Respiration (Impedance Method) Accuracy of Sensitivity 10 mm / 1 Resp. Display Range 0, 9 to 150 bpm Display Error of Respiration Rate ± 3 bpm Measured Current of Respiration Below 100 A (at 42 kHz) ± 2 mm Pulse Wave SpO2 SpO2 Measurement Range 1 to 100 % Resolution 1% Measurement Accuracy (Nellcor® Technology) SpO2 Probe Measurement Accuracy (± 1SD) OxiMax® MAX-I OxiMax® MAX-P OxiMax® MAX-A/AL Durasensor® DS-100A OxiMax® MAX-R OxiMax® MAX-FAST OxiMax® MAX-N (Less than 70 % is not specified) Measurement Response Time Measurement Value Update Rate and above ± ± ± ± ± ± ± 2% 2% 2% 3% 3.5 % 2% 2% Transmission Method Frequency 608 to 614 MHz Oscillation Method Measurement Accuracy ± 3 bpm Measurement Response Time 6 to 7 sec. (Averaging time) Measurement Value Update Rate 1 second General Standard IEC60601-1:1988 + A1: 1991 + A2: 1995 EMC Standard IEC60601-1-2: 2007 Shock Hazard Type CF Applied Part Operating Environment 1 second Digital 20 to 250 bpm Safety 6 to 7 sec. (Averaging time) Modulation Mode Pulse Rate Measurement Range Temperature 10 to 40 °C Humidity 30 to 85 % RH (No condensation) Vibration/Shock Comply with IEC60068-2-64:1987, IEC60068-2-32:1975, IEC60068-2-6:1995 Transport / Storage Environment Temperature -10 to 60 °C PLL Synthesizer method by crystal control Humidity 10 to 95 % RH (No condensation) Channel Spacing 12.5 kHz Standard Accessories Occupied Frequency Bandwidth 8.5 kHz RF output power 1 mW ± 2 dB Transmitting Antenna ECG lead cable and/or SpO2 Probe Neck Strap OA-311 4-electrode lead cable CMT-02HTH-0.8DA Operation Manual ECG Monitoring 3-electrode lead cable 1 waveform White (RA) Black (LA) 4-electrode lead cable 2 waveforms White (RA) Green (RL) Red (LL) Cable: CMT-01HTH-0.8DA ECG 1: lead I, lead II, or lead III Black (LA) Red (LL) Cable: CMT-02HTH-0.8DA ECG 1 and 2: lead I, lead II, lead III, aVR, aVL, aVF 5-electrode (chest) lead cable 2 waveforms White (RA) Green (RL) Black (LA) Brown (V) Red (LL) Cable: CMT-03HTH-0.8DA ECG 1: lead I, lead II, or lead III ECG 2: V lead Fukuda Denshi USA, Inc 17725-C NE 65th Street Redmond, WA 98052 USA Toll Free Free: (800) 365-6668 / Local Local: (425) 881-7737 / Fax Fax: (425) 869-2018 www.fukuda.com The information contained in this document is subject to change without notice. Nellcor®, OxiMax® and Durasensor® are registered trademarks of Covidien. © 2011 Fukuda Denshi USA, Inc. All rights reserved. Document No. USRB-0010-01