Triax Distribution Amplifiers [2005] 1.indd
Transcription
Triax Distribution Amplifiers [2005] 1.indd
Triax Distribution Amplifiers for community networks Flexibility from trunk line to subscriber in current to future networks 1 L arge, medium and small TRIAX Amplifiers for SMATV and CATV Triax range of amplifiers covers all levels in the community network - from trunk line, to distribution lines and to individual problem solving at the subscriber end. Operational reliability is a must and is included in almost any amplifier offered today by leading suppliers. Triax offers more in terms of performance, for example extremely high output level and low noise figures making the amplifiers well suited for networks with a high channel density. But, first of all, our network amplifiers are designed to simplify, i.e. to save time and money for both installers and network operators. • Simplifying tomorrow: Subscriber needs change as new opportunities emerge. In all our network amplifiers, the configuration can be changed in seconds by simple adjustments of inexpensive plug-in modules. An active or passive return path to handle interactive services can easily be established and many of the amplifiers are well suited as stepping-stones for future expansions of the network. • C4 Superbroadband Distribution Amplifiers making SAT-IF distribution (up to 2400 MHz) a viable possibility even in large distribution networks and for example to increase the • Simplifying today: Even in large and complex networks only a relatively small number of different, but flexible Triax amplifiers and plug-in modules are needed. All the amplifiers are easily configurable on site and include features to facilitate both testing and adjusting the system. Onestop-shopping furthermore ensures a coherent system and easy access to efficient technical support. From trunk line to subscriber To cover any amplification need, Triax offers variety of TVprograms offered in an existing cable network. • C3 Trunk and Distribution Amplifiers with high output levels and based on GaAs-FET technology ensuring extremely low distortion figures (CTB and CSO), low current consumption and low noise figures even at high frequencies. 2 C3 and C4 plug-in modules • HFA Distribution Amplifiers Let us help with answers or a complete system proposal available at different gain levels with excellent performance figures and with Triax Automatic Link Pass (ALP) technology establishing the forward signal automatically and without any plug-in modules. Giving precise and understandable answers is probably the most important way of keeping it simple. Triax support is only a phone call away, and we will assist you with useful answers. Furthermore we offer you complete planning and documentation of community networks. Quality content in quality housing • IFA Distribution Amplifiers with 1 or 2 outputs, 20 dB or 30 dB gain and all the features and flexibility making them well suited for low-cost installation at the subscriber end of the network. All Triax network amplifiers are effectively shielded and protected by quality housing fulfilling all the relevant and acknowledged international and national standards. C3, C4 and HFA amplifiers are in aluminium die-cast housing ensuring both mechanical protection (IP66/IP65 requirements) and a high shielding factor. Quality housing with easy access to connections, adjustment functions, test points and plug-in slots facilitate the installation, and this especially applies to Triax IFA amplifiers with their “click-on” mounting brackets and easy access to both connections and adjustment controls. Based on computer software, we can provide you with specifications of the right solution, including drawings, performance calculations and a part list of all the equipment needed. All you have to do is to specify network requirement, using the checklist on www.triax.com and specify demands by e-mail from the website. One-stopshopping TRIA X Othe r Ch eck C/N in signals, list, cont trans proj ition . Signa ect point l varia : tio Retur n path n +/- dB in frequ trans ition ency point range Conn *: : ectio Numb ns er of subs Numb cribe er r conn Distan of outlets per su ections: ce fro bscri m tra Floor Cust ber: nsitio Chec distan omer n point ce: Bran k lis Date: inform to mo ch co t, pr nnec st rem ation ojec Custo tion ter ote ou t mer: mina tlet: Instal Addre ted: ss: lation loft: Draw Tel.: area ing of base dimen Loca E-ma ment: tion of siona il: l ac he Loca enclo Conta curac aden tion of sure: d on y of ins ct pe drawin mast rson: Distan Instal tal lat other on g: ion are lation ce of drawin place anten start Loca a with Do yo g: s: Fax: time: tion of nas/d routin ish desc u want an ampli gs/ca Loca riptio fier en es to head tion of ble tra n of theestimate closu en ce: su Ca Brief of d: bs ble len re*: the pri projec cribe gene r gths ce of t/spe ral de Colou stated enclosure* cifica a detai scrip r tion) of ca : tion of may led pro binets Regis vary the pro ject, max tratio and en or a qu ject, %: ns closu /Con new otatio struc res: netw n (a qu tiona ork or Po werota l restric renov sutiopp n req tions ation 22 Ante ly uires a Gree of loc of ex 0V*: n: nnas ation comp isting Lin How of ma lete e sune / Dish Grey ma pptw Howe st an ly*ork : : :: Are av d dis ver, ma Which ny SAT po es h: ailab sition x me SAT le 22 ters: s: posit Which 0V co ion yes: polar s: nnec Instal ities*: tions Signa lation indica l stren no: Is ted on the he enviro gth fro How drawin ma m nmen Ambie adend to g*: Which ny terrestria LNB*: be t nt of he wall or tempe chan l: aden rature rack ne Signa yes: d moun range l stren ls / transmi Head ted: at he gth*: en tters: FM / no: aden any tim d equip DA d: me e rea Signa B: ches nt should l stren alw 35ºC gth*: or mo ays be Tech place re nical d in an Head Proje requ end cti airco How nditio CENE ng will alw iremen ma ned en ts LEC EN 50 ays be in viron Numb ny channe ment, ac 083. er ls: If oth cordanc if the Numb of Mono/St e er or ambie er ere highe with the nt tem Numb of DVB-S/D o: r requir current perat er mi VB-T emen ure at Numb of DVB-S ts are nimum req for Pa All po er for QA l: dema ints of M: nded uirements Numb of Free to Point , pleas s ma this form of er Air/C rked I an e sta antenna Which of DVB-S * may should be te wh syste for FM d encodin progra ich: be lef filled ms sta g: : Info ch ms: in, t out. ted in anne In tha if possibl l: Surve t case e, illanc minim if not the e came TRIAX Retur es um va A/S n path: ra: lues sential req will for Optio uir ns for m the ements mu progra basis yes: Bjørnk yes: of the st be agree m pa 8783 ærvej 3 ckag subs Othe no: es: Denm Hornsyld eque d on. no: r ark nt pro yes: Signa signals yes: jectin l from g. Phone existing Numb no: no: er of Telefa : +45 76 CATV 82 chan x: Signa 22 00 : A/S reg +45 75 nels l stren 68 . nr. 46.842 72 88 gth low and frequ CTB/I Ba en MA in /high nk: cy ran frequ trans e-mail: Nordea ge: ency ition www.t triax@tria : po int*: riax.dk TRIAX x.dk TRIA X • ACB and ATB Amplifier Series with 2 inputs and 1 output, active or passive in the frequency range 4-862 MHz and active in the frequency range 950-2150 MHz, overall a well suited amplifier for low-cost installation in minor networks. A/S Bjørnk 8783 ærvej 3 Denm Hornsyld ark Phone Telefa : +45 76 A/S regx: +45 75 82 22 00 68 . nr. 46.842 72 88 3 Bank: e-mail: Nordea www.t triax@tria riax.dk x.dk M aximum output, Maximum flexibility C3 Trunk Line and Distribution Amplifiers Triax C3 series is a complete amplifier system for achieving trunk line output levels combined with all the options and flexibility needed for optimizing a distribution network in terms of performance and minimum investment. • Flexibility: A wide range of both built-in options and plug-in modules enables the installer to adapt the amplifier to almost any requested system design, including easy access to later re-configuration against new requirements C3 Trunk Line Amplifiers C3 Distribution Amplifiers Linearity is a key requirement to trunk line amplifiers and with flatness figures > +/- 0.5 dB, the C3 Trunk Line Amplifiers fully meet this requirement. Other performance data are also outstanding and in addition, the C3 Trunk Line Amplifiers feature for example: The C3 Distribution amplifiers have switchable main amplification (28 dB / 36 dB) and are especially suitable as medium and large distribution amplifiers. Features include - Interstage plug-in socket for fitting of equalizer or attenuator. The plug-ins have no negative effect on maximum output level or the amplifiers’ noise figures • Interstage plug-in socket for fitting of equalizer or attenuator • Bi-directional test socket for measuring the input signal without interrupting operation or opening the amplifier • Performance: Using GaAs-FET technology C3 amplifiers combine high output levels with extremely low distorsion figures (CTB and CSO), low current consumption and low noise figures even at high frequencies. Reduced distorsion at high frequencies allows efficient adjustment of output levels to compensate for higher attenuation • Prepared for the future: Interactive services are fully supported by C3 amplifiers and the return path is easily configured (frequency range, amplification, etc.) with flexible plug-in modules. Other future options include expanding the distribution system by activating a second amplifier output with only a minimum loss in output level. As the technical data clearly shows, C3 amplifiers are products of high quality. When you add an economic dimension and relate quality and flexibility to price, C3 are first class. C3 Distribution Amplifier C3 Trunk Line Amplifier • Test sockets at input and output allowing measurements without interrupting operation • A second output, that can be configured as a tap line (with minimum attenuation), a distribution line or as feed-in of remote fed power • Transit current separately configurable for all inputs and outputs via fuses • All models available for mains supply or for line powering with up to 7 A power pass • Efficient surge and transient protection. 4 • A second output, that can be configured as an operating or as a test output • Transit current separately configurable for input and output • All models available for mains supply or line powering. With their efficiency to suppress interference, the amplifiers are especially suited for networks with a high channel density. 8 7 6 5 5 10 4 11 9 13 12 2 14 14 3 1 C3 Trunk Line Amplifier Quick on-site configuration with plug-ins C3 Trunk Line Amplifier Efficiency flatness figures +/- 0.5 dB and with a maximum output level of 119 to 126 dBµV Our C3 series includes plug-in modules for 1 2 3 4 5 6 7 8 9 10 11 12 13 14 • establishing an active or passive return path • equalization in both the forward and the return path • variable attenuation • configuration of a second output with taps or a splitter • establishing an external test socket. The modules are fully protected and are easily inserted in the correct position. Signal input Splitter or tap module Line out Test socket Return path filter Equalizer Attenuator Interstage plug-in socket Test socket Active/passive return path Return-path equalizer Remote feeding on/off Splitter or tap module Signal-/test output C3 Distribution Amplifier with a maximum output level of 122 to 126 dBµV 7 6 5 4 9 3 3 10 2 1 8 11 11 C3 Distribution Amplifier 5 1 2 3 4 5 6 7 8 9 10 11 Signal input Test socket Return path filter Attenuator Equalizer Interstage plug-in socket Amplification switch Variable output configuration Active/passive return path Selection of power feeding Signal output TRIAX Check list, project Customer information E xtend the possibilities in SAT-IF distribution C4 Superbroadband Distribution Amplifiers Date: Customer: Address: Tel.: Fax: E-mail: Contact person: Installation start time: Do you want an estimate of the price of a detailed project, or a quotation (a quotation requires a complete description of the project/specification) Brief general description of the project, new network or renovation of existing network:: A distribution network based on SAT-IF distribution is a direct and uncomplicated single cable solution. Antennas / Dishes TheSAT network How many positions: can be a satellite only Whichsolution, SAT positions:but SAT-IF distribution can Which polarities*: also be used to widen the variety of Signal strength from LNB*: How many terrestrial: offered in an existing cable programs Which channels / transmitters: network or a terrestrial system. With Signal strength*: C4 amplifiers SAT-IF distribution FM / DAB: Signalbecomes strength*: a practical and economic possibility even in large distribution Headend How many channels:including several buildings or systems Number of Mono/Stereo: community estates. Number of DVB-S/DVB-T for Pal: Number of DVB-S for QAM: Number of Free to Air/CI and encoding: Number of DVB-S for FM: Which programs: Info channel: Surveillance camera: yes: Return path: Options for program packages: yes: Excellent performance even in the high yes: no: frequency range yes: A multitude of possibilities for configuration To achieve a practical system design and ensure every subscriber a reliable signal, C4 amplifiers can be adapted and configured in all the relevant ways: • Interactive services can easily be supported by inserting an active or passive plug-in module • Input signals from an existing distribution system can have a separate feed-in cable or inputs can be combined in one cable • Amplifiers are available with switchable as well as fixed amplification no: no: no: The superbroadband Other signals amplifiers of the C4 series amplify a frequency range up to 2400 MHz. Signal from existing CATV: Number of channels and frequency range: Signal strength low/high frequency: CTB/IMA in transition point*: With GaAs-FET technology Phone: +45 76 82 22 00 Bjørnkærvej 3 Telefax: +45 75 68 72 88 8783combine Hornsyld C4 amplifiers high A/S reg. nr. 46.842 Denmark output levels with extremely low distorsion figures (CTB and CSO), low current consumption and low noise figures even at high frequencies. TRIAX A/S Bank: Nordea e-mail: [email protected] www.triax.dk The amplifiers are equipped with two separate amplifier lines for the range up to 862 MHz and for the range from 950 to 2400 MHz. The maximum output level ranges from 120 to 124 dBµV. • An equalizer is either built-in or both a fixed and a variable equalizer can be inserted as plug-in modules • A variable attenuator can be inserted as plug-in module • Amplifiers are available for mains power as well as line powering. 6 C4 Superbroadband Distribution Amplifier 5 with a maximum output level of 120 to 124 dBµV 6 4 8 7 1 2 3 4 5 6 7 8 9 10 4 9 3 1 2 10 Quick on-site configuration with plug-ins Triax SCT Satellite IF/IF converter is value for money Plug-in modules for C4 are identical with the plug-in modules used for C3 Trunk and Distribution Amplifiers As head-end in the SAT-IF distribution system, Triax supplies the SCT Satellite IF/IF Converter that converts every required SAT-IF channel from its original frequency to an optimized frequency within the output range of 950 to 2150 MHz. • establishing an active or passive return path • equalization in both the forward and the return path • variable attenuation • configuration of a second output with taps or a splitter • establishing an external test socket. The modules are fully protected and are easily inserted in the correct position. Input 1 SAT input SAT plug module Return path filter Return path equalizer Interstage plug-in socket Return path equalizer Active/passive return path Selection of power feeding Output Opportunity The SCT converter handles both digital and analogue satellite signals. It is available with 6 or 12 input channels, and two units can easily be built together and handle up to 36 channels. Programming on site is easy and the unit furthermore has a range of valuable features, and a competitive price. TRIA X Othe r C/N in signals, cont trans ition . Signa po Chec l varia int: tio n path n +/- dB in frequ trans ition ency point range *: : Retur TRIA X k lis t, proj ect Conn ec tions Numb er Numb of subscri ber co er nn Distan of outlets per su ections: ce fro bscri m tra Floor Cust ber: nsitio Chec distan omer n point ce: Bran k lis Date: inform to mo ch co t, proj nnec st rem ation Custo tion ter ect ote ou mer: mina tlet: Instal Addre ted: ss: lation loft: Draw Tel.: ar ing of ea base dimen Loca E-ma ment: tion of siona il: l accu head Loca enclo Conta racy end on tion of sure: ct pe of ins drawin mast rson: Distan Instal tal lation other on dra g: lation ce of place area wing: anten start Loca Do yo with rou s: Fax: time: tion of nas/d tings ish desc u want an ampli Loca /cable riptio fier en es to head estim tion of n trace ate of clo en subs the pro Cable Brief sure* of d: : cribe gene : length ject/s the price r enclo ral de pecif Co s of sta a su lou scrip icatio detai ted ma re*: r of ca tion of led pro n) y vary binets Regis the pro ject, ma tra an or tio d x %: ject, enclo ns/Con a quota new sures struc tion (a netw : tiona ork or Powe quota l restric renov r sutiopp n req tions ation 22 Ante ly uires a Gree of loc of ex 0V*: n: nnas ation comp isting Lin How of ma lete e sune / Dish Grey pptw ma Howe st an ly*ork : : :: Are av d dis ver, ma Which ny SAT po es h: ailab sition x me SAT le 22 ters: s: posit Which 0V ions: conn yes: polar Instal ectio ities*: Signa ns ind la tio l stren no: icated Is the n envi gth fro How on dra head ronm many m LN end to win Am en B* ter g*: bie Which : restria be wa t nt tem chan ll or rac of head l: perat nels Signa en ure ye k d mo / s: range trans l stren Head unted mitte at he gth*: en : FM / rs: no: aden any tim d equip DA d: me e rea Signa B: ches nt should l stren alw 35ºC gth*: or mo ays be Tech place re nical d in an Head Proje requ end cti airco How nditio CENE ng will alw iremen many ned en ts LEC ays be ch EN viron Numb anne in 5008 ment, er ls: 3. If oth accorda if the nce Numb of Mono/St er or ambie er ere highe with the nt tem Numb of DVB-S/D o: r requir current perat er mi VB-T emen ure at Numb of DVB-S ts are nimum req for Pa All po er for QA l: dema ints of M: nded uirements Numb of Free to Point , pleas s ma this form of er Air/C rked I and e sta antenna shou Which of DVB-S * te ld en ma for FM which systems be codin progra y be : g: : left ou filled in, Info ch ms: stated t. In tha if poss anne in l: Surve t case ible, if no illanc minim t e came TRIAX Retur um va the essenti A/S n path: ra: lues will for al requirem Optio ns for m the en progra basis ts must yes: Bjørnk yes: be ag of the m pa 8783 ærvej 3 ree ck su Ho ag d Othe bseq no: es: Denm rnsyld no: uent on. r ark projec yes: Signa signals yes: ting. l from Phone existing Numb no: no: er of Telefa : +45 76 CATV chan Signa : A/S regx: +45 75 82 22 00 nels l stren 68 . nr. 46.842 72 88 gth low and frequ CTB/I Bank: ency MA in /high range frequ trans e-mail: Nordea : ency ition tria www.t x@tria : point riax TR x.d *: IAX A/S .dk Bjørnk 8783 ærvej 3 Denm Hornsyld ark Phone Telefa : +45 76 A/S regx: +45 75 82 22 00 68 . nr. 46.842 72 88 7 Bank: e-mail: Nordea www.t triax@tria riax.dk x.dk k P owerful, reliable and easy to install HFA Distribution Amplifiers With the HFA series of broadband distribution amplifiers, both the installer and the network operator obtain all the benefits of a quality product: Reliability and a long lifetime, quick installation, effective shielding and the option to use the network for all conceivable interactive services. The high performance amplifiers are available in versions with different gain levels (22 dB, 30 dB and 40 dB). They all have adjustable gain, variable tilt (0-18 dB) and are available for both line and mains powering. If you have chosen a return path range of 5-30 MHz and want to increase it to 5-55 MHz or 5-65 MHz you just exchange the two Diplex plug-in modules. The amplifier is the same and needs not to be replaced. High performance and effective shielding Few types cover it all HFA amplifiers are available in 6 versions: • 22 dB, mains or line powered • 30 dB, mains or line powered • 40 dB, mains or line powered The amplifiers use push-pull technology, which ensures low distortion and a high output voltage. Input and outputs are efficiently transient protected up to 4 kV. No plug-in modules are needed for the forward path Triax’ newly developed Automatic Link Pass (ALP) automatically establishes the forward signal ensuring a linear amplification in the entire 47-862 MHz range. No plug-in link modules are needed for forward path, only for the return path. Passive or active return path - you decide when and how When the return path is to be used, it is simply done by mounting Diplex plug-in modules on input and output. The type of module inserted determines, whether the return path range is 5-30 MHz, 5-55 MHz or 5-65 MHz, and whether it is passive or active. The return path is automatically established by the ALP function. Diplex plug-in modules • with or without test point • with a return path range of 5-30, 5-55 or 5-65 MHz Active plug-in return path amplifier with 17 dB gain covering the whole return path frequency range at 5-65 MHz is also available. 8 The passive return path is established by inserting two Diplex plug-in modules. The active return path is quickly established, simply by inserting a plug-in return path amplifier. The active frequency range is determined by the Diplex modules. Quality housing ensures long life The aluminium die-cast housing of the amplifier offers high mechanical stability and ensures a high shielding factor. Aluminium dissipates the heat much better than comparative materials. This results in a constant value and a long product life. The HFA housing complies with the IP65 requirements for efficient dust and water protection. Quality The installation of the amplifier can either be left/right or top/bottom. All mounting accessories are delivered with the amplifier. Efficient switch mode power supply adds to reliability The switch mode power supply has a high efficiency that minimizes heat generation and power consumption. The excellent transient and surge protection combined with the low operating temperature all contribute to increase and ensure a long lifetime of the amplifier. An LED indicator shows whether the power supply is working correctly. 9 L ow-cost trouble solving IFA Distribution Amplifiers At the subscriber end of almost any community network, the installer will need handy and reliable broadband amplifiers to provide signals of sufficient strength to, for example, a distant block of flats or to subscribers wanting outlets in more than one room. From both a technical and economical point of view Triax IFA amplifiers are ideal for this kind of installation. Relative to their high performance and effective shielding, they are inexpensive and quick to mount anywhere indoors. A wide range of solutions IFA amplifiers are available with 1 or 2 outputs and in 20 dB as well as 30 dB gain variants, all provided with variable attenuator. Moreover, some types have 5-7 dB fixed tilt, others are provided with variable tilt to equalize the uneven attenuation of the low and the high frequencies of the cable. “Click-on” bracket saves installation time When the amplifier is to be mounted on a wall or rafter, the rear grey/white bracket is screwed on, cables with F-connectors are screwed on to the amplifier, which can now be clicked on to the rearmounting bracket. In case of subsequent changes to the cables, the amplifier is easily demounted by pressing down the small ratchet and then pulling the amplifier loose from the rearmounting bracket. Integrated return path for support of interactive services All amplifiers in the IFA-series have an integrated passive return path to the frequency ranges 5-30, 5-55 or 5-65 MHz. If or when the network has to be used for interactive services such as fast Internet connections, interactive TV or cable telephony, IFA amplifiers will thus support these interactive applications. High output voltage and transient protection IFA amplifiers have a very high output voltage of 116 dBµV or 2 x 112 dBµV (EN 50083-3). This makes them suitable for aerial systems with many channels. They are transient protected up to 4 kV on all inputs and outputs. IFA 203 Amplifier with 2 outputs and gain adjustment 10 IFA 231 Amplifier with 1 output, equalizer and gain adjustment IFA 236 Amplifier with 2 outputs, equalizer and gain adjustment IFA 205 Amplifier with 1 output, equalizer and gain adjustment Design and installation Flexibility With a modern and elegant design, IFA Distribution Amplifiers are suitable for mounting even inside homes and in situations, where the installation cannot be hidden away in a loft or under a staircase. 11 C3 High output Trunk Line Amplifiers Technical Data - Mains powered TYPE C3 S250 C3 SC360 C3 SC300 C3 SG400 Part No. 321250 321360 321300 321400 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 25 36 31 41 Forward Path Frequency range MHz Gain switchable - pos. 1 dB dB Noise figure dB 7.5 7.5 7.5 7.5 Linearity dB ± 0.5 2) ± 0.5 2) ± 0.5 2) ± 0.5 2) Attenuation dB 0 - 20 0 - 20 0 - 20 0 - 20 Equalization dB depending on module depending on module depending on module depending on module Output level @ 450 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 124 117 112 112 122 124 117 112 112 122 128 119 117 118 128 119 117 118 Output level @ 600 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 123 117 109 119 121 123 117 109 119 121 128 119 114 115 128 119 114 115 Output level @ 862 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 122 115 107 107 120 122 115 107 107 120 126 118 112 113 126 118 112 113 Return loss (-1.5 dB/Octave) dB Output stage 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz Power Doubling Power Doubling GaAs-FET GaAs-FET 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) -10..0/2..12/14..24 Return path Frequency range MHz Gain (adjustable) dB -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 Noise figure dB 6.0 2) 6.0 2) 6.0 2) 6.0 2) Attenuation dB 0 - 10 0 - 10 0 - 10 0 - 10 Equalization dB depending on module depending on module depending on module depending on module Main supply Main supply Main supply Main supply 180 - 255 180 - 255 180 - 255 180 - 255 W 13 13 13 13 A 7 7 7 7 IP66 IP66 IP66 IP66 PG11 (5/8” on request) PG11 (5/8” on request) PG11 (5/8” on request) PG11 (5/8” on request) General Power supply type Power supply V/AC Power consumption Current-transit 3) Housing - Protection class Connectors Certification Impedance Operation temperature range Weight 75 75 75 75 0 -20....+55 -20....+55 -20....+55 -20....+55 C kg Dimensions (H x D x W) 1) 2) 3) Ohm mm 2.5 2.5 2.5 2.5 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Values apply to use with return-path module VRA 365 Hum modulation ratio >65 dB C3 - S250 C3 - S360 12 C3 - SG300 C3 - SG400 C3 High output Trunk Line Amplifiers Technical Data - Line powered TYPE C3 T251 C3 T361 C3 TG301 C3 SG401 Part No. 321251 321361 321301 321401 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 25 36 31 41 Forward Path Frequency range MHz Gain switchable - pos. 1 dB Noise figure dB 7.5 7.5 7.5 7.5 Linearity dB ± 0.5 2) ± 0.5 2) ± 0.5 2) ± 0.5 2) Attenuation dB 0 - 20 0 - 20 0 - 20 0 - 20 Equalization dB depending on module depending on module depending on module depending on module Output level @ 450 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 124 117 112 112 122 124 117 112 112 122 128 119 117 118 128 119 117 118 Output level @ 600 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 123 117 109 119 121 123 117 109 119 121 128 119 114 115 128 119 114 115 Output level @ 862 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 122 115 107 107 120 122 115 107 107 120 126 118 112 113 126 118 112 113 Return loss (-1.5 dB/Octave) dB Output stage 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz Power Doubling Power Doubling GaAs-FET GaAs-FET 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) -10..0/2..12/14..24 Return path Frequency range MHz Gain (adjustable) dB -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 Noise figure dB 6.0 2) 6.0 2) 6.0 2) 6.0 2) Attenuation dB 0 - 10 0 - 10 0 - 10 0 - 10 Equalization dB depending on module depending on module depending on module depending on module Line supply General Power supply type Power supply Power consumption Current-transit Line supply Line supply Line supply V/AC 24 - 70 24 - 70 24 - 70 24 - 70 W 13 - 14 13 - 14 13 - 14 13 - 14 3) A Housing - Protection class Connectors 7 7 7 7 IP66 IP66 IP66 IP66 PG11 (5/8” on request) PG11 (5/8” on request) PG11 (5/8” on request) PG11 (5/8” on request) Certification Impedance Operation temperature range Weight 75 75 75 75 0 -20....+55 -20....+55 -20....+55 -20....+55 C kg Dimensions (H x D x W) 1) 2) 3) Ohm mm 2.5 2.5 2.5 2.5 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Values apply to use with return-path module VRA 365 Hum modulation ratio >65 dB C3 - T251 C3 - T361 C3 - TG301 13 C3 - SG401 C3 High output Distribution Amplifiers Technical Data - Mains powered TYPE C3 SC500 C3 SC600 C3 SG180 C3 SCG700 Part No. 321500 321600 321180 321700 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 28 36 28 36 18 32 40 Forward Path Frequency range MHz Gain switchable - pos. 1 - pos. 2 dB dB Noise figure dB 7.0 7.0 7.0 7.0 Linearity dB ± 0.75 2) ± 0.75 2) ± 0.75 2) ± 0.75 2) Attenuation dB 0 - 20 0 - 20 0 - 20 0 - 20 Equalization dB depending on module depending on module depending on module depending on module Output level @ 450 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 120 115 110 111 118 124 117 112 112 122 128 119 117 118 128 119 117 118 Output level @ 600 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 120 115 107 108 118 123 117 109 109 121 128 119 114 115 128 119 114 115 Output level @ 862 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 119 111 105 106 117 122 115 107 107 120 126 118 112 113 126 118 112 113 Return loss (-1.5 dB/Octave) dB 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz Push pull Power Doubling GaAs-FET GaAs-FET 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) -10..0/2..12/14..24 Output stage Return path Frequency range MHz Gain (adjustable) dB -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 Noise figure dB 6.0 2) 6.0 2) 6.0 2) 6.0 2) Attenuation dB 0 - 10 0 - 10 0 - 10 0 - 10 Equalization dB depending on module depending on module depending on module depending on module Main supply Main supply Main supply Main supply 180 - 255 180 - 255 180 - 255 180 - 255 W 10 14 14 14 A - - - - IP66 IP66 IP66 IP66 3 x F-con 3 x F-con, PG11 or 5/8” PG11 or 5/8” PG11 or 5/8” General Power supply type Power supply V/AC Power consumption Current-transit 3) Housing - Protection class Connectors Certification Impedance Operation temperature range Weight 75 75 75 75 0 -20....+55 -20....+55 -20....+55 -20....+55 C kg Dimensions (H x D x W) 1) 2) 3) Ohm mm 2.0 2.0 2.0 2.0 163 x 60 x 242 163 x 60 x 242 163 x 60 x 242 163 x 60 x 242 DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Values apply to use with return-path module VRA 365 Hum modulation ratio >65 dB C3 - SC500 C3 - SC600 14 C3 - SG180 C3 - SCG700 C3 High output Distribution Amplifiers Technical Data - Line powered TYPE C3 TC501 C3 TC601 C3 TG181 C3 TCG701 Part No. 321501 321601 321181 321701 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 28 36 28 36 18 32 40 Forward Path Frequency range MHz Gain switchable pos. 1 pos. 2 dB dB Noise figure dB 7.0 7.0 7.0 7.0 Linearity dB ± 0.75 2) ± 0.75 2) ± 0.75 2) ± 0.75 2) Attenuation dB 0 - 20 0 - 20 0 - 20 0 - 20 Equalization dB depending on module depending on module depending on module depending on module Output level @ 450 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 120 115 110 111 118 124 117 1112 112 122 128 119 117 118 128 119 117 118 Output level @ 600 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 120 115 107 108 118 123 117 109 109 121 128 119 114 115 128 119 114 115 Output level @ 862 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 119 111 105 106 117 122 115 107 107 120 126 118 112 113 126 118 112 113 Return loss (-1.5dB/Octave) dB 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz Push pull Power Doubling GaAs-FET GaAs-FET 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) -10..0/2..12/14..24 Output stage Return path Frequency range MHz Gain (adjustable) dB -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 Noise figure dB 6.0 2) 6.0 2) 6.0 2) 6.0 2) Attenuation dB 0 - 10 0 - 10 0 - 10 0 - 10 Equalization dB depending on module depending on module depending on module depending on module Line supply Line supply Line supply Line supply 24 - 70 24 - 70 24 - 70 24 - 70 W 10 14 14 14 A 2.5 2.5 2.5 2.5 General Power supply type Power supply V/AC Power consumption Current-transit 3) Housing - Protection class Connectors IP66 IP66 IP66 IP66 3 x F-con 3 x F-con, PG11 or 5/8” PG11 or 5/8” PG11 or 5/8” Certification Impedance Operation temperature range Weight 75 75 75 75 0 -20....+55 -20....+55 -20....+55 -20....+55 C kg Dimensions (H x D x W) 1) 2) 3) Ohm mm 2.0 2.0 2.0 2.0 163 x 60 x 242 163 x 60 x 242 163 x 60 x 242 163 x 60 x 242 DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Values apply to use with return-path module VRA 365 Hum modulation ratio >65 dB C3 - TC501 C3 - TC601 C3 - TG181 15 C3 - SG701 C4 High output Superbroadband Distribution Amplifier Technical Data - Mains and line supply TYPE C4 S250 C4 T251 C4 S360 Part No. 324250 324251 324360 321400 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) 47, 73 or 86 - 860 (depending on filter) Frequency range MHz C4 T361 Gain switchable 47 - 862 MHz 950 - 2400 MHz dB dB 25 40 25 40 36 40 36 40 Noise figure 47 - 862 MHz 950 - 2400 MHz dB dB < 8.5 < 9.0 < 8.5 < 9.0 < 6.5 < 9.0 < 6.5 < 9.0 dB ± 0.5 2) ± 0.5 2) ± 0.5 2) ± 0.5 2) Attenuation 47 - 862 MHz 950 - 2400 MHz dB dB 0 - 10 0 - 20 0 - 10 0 - 20 0 - 20 0 - 20 0 - 20 0 - 20 Equalization 47 - 862 MHz 950 - 2400 MHz dB dB 0 - 20 0 - 20 0 - 20 0 - 20 0 - 20 0 - 20 0 - 20 0 - 20 Linearity Output level @ 450 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 124 117 112 112 122 124 117 112 112 122 124 117 112 112 122 124 117 112 112 122 Output level @ 600 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 123 117 109 109 121 123 117 109 109 121 123 117 109 109 121 123 117 109 109 121 Output level @ 862 MHz 60 dB IM3 (DIN 45004B) 60 dB IM2 (DIN 45004A1) 60 dB CTB 1) 60 dB CSO IM3 - 52 dB 3 carrier dBµV dBµV dBµV dBµV dBµV 122 115 107 107 120 122 115 107 107 120 122 115 107 107 120 122 115 107 107 120 Output level @ 2400 MHz 60 dB IM3 (DIN 45004B) dBµV Return loss (-1.5 dB/Octave) dB 120 120 120 120 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 20 @ 40 MHz 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) 5-30, 5-55 or 5-65 (depending on filter) Return path Frequency range MHz Gain (adjustable) 5-65 MHz dB -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 -10..0/2..12/14..24 Noise figure 5-65 MHz dB 6.0 2) 6.0 2) 6.0 2) 6.0 2) Attenuation 5-65 MHz dB 0 - 10 0 - 10 0 - 10 0 - 10 Equalization 5-65 MHz dB 1 1 1 1 Main supply Line supply Main supply Line supply 180 - 255 24 - 70 180 - 255 24 - 70 16 16 16 16 General Power supply type Power supply V/AC Power consumption Current-transit W 3) A Housing - Protection class Connectors 7 (Hum modulation ratio 65 dB, f= 10 MHz) 7 (Hum modulation ratio 65 dB, f= 10 MHz) IP66 IP66 IP66 IP66 4 x PG11 4 x PG11 4 x PG11 4 x PG11 Certification Impedance Operation temperature range Weight Ohm 75 75 75 75 0 -20....+55 -20....+55 -20....+55 -20....+55 C kg Dimensions (H x D x W) mm 2.5 2.5 2.5 2.5 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 163 x 90 x 242 1) DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels 2) Values apply to use with return-path module VRA 365 3) Hum modulation ratio >65 dB C4 - S250 C4 - T251 16 C4 - S360 C4 - T361 Facts about Plug-in modules for C3 & C4 Amplifiers Input modules for C4 amplifiers Service module TYPE ECO 003 TYPE Part No. 321003 Part No. Frequency range Input 1 Input 2 MHz MHz 5 - 862 950 - 2400 Frequency range Test point VMS 1 321100 MHz dB 4 - 65 - 20 Return-path modules passive/active TYPE VRP 035 VRA 465 VRA 355 Part No. 321035 321465 321355 4 - 30 4 - 55 4 - 65 -10 to 0 2 - 12 14 - 24 - 113 113 TYPE FVR 030 FVR 055 FVR 065 Part No. 321030 321055 321065 4 - 30 4 - 55 4 - 65 0.5 0.5 0.5 Frequency range Amplification Output level (60 dB IMA) MHz dB dBµV Return-path filters Frequency range Through loss MHz dB Adaptor for C3 & C4 Attenuators TYPE ATT 020 Part No. 321020 Frequency range Through loss MHz 4 - 862 dB 0 - 20 TYPE Dimension Weight TYPE EVR 130 EVR 155 EVR 165 Part No. 321130 321155 321165 MHz 4 - 30 4 - 55 4 - 65 Equalization dB 0 - 10 0 - 10 0 - 10 Basic attenuation dB -1 -1 -1 Output modules 4 - 862 MHz TYPE VMM 20 SDE 004 SDE 007 SDE 014 Part No. 321002 321004 321007 321014 Test socket Splitter Tap Tap Version Output 1 dB - 0.5 - 4.0 - 2.0 - 1.0 Output 2 dB - 20.0 - 4.0 - 7.0 - 14.0 17 153580 mm kg Variable return-path equalizers Frequency range PG11 - Ff Part No. HEX 20 x 72.5 0.046 Facts about Plug-in modules for C3 & C4 Amplifiers Variable equalizers TYPE EGA 101 EGA 201 Part No. 321101 321201 MHz 4 - 862 4 - 862 Equalization @ 47 MHz dB 0 - 10 0 - 20 Basic attenuation dB -1.0 -1.0 TYPE EGA 006 EGA 012 Part No. 321006 321012 4 - 862 4 - 862 Frequency range Fixed equalizers Frequency range MHz Equalization @ 47 MHz dB 6.0 12.0 Basic attenuation dB -1.0 -1.0 Fixed return-path equalizers TYPE VMR 3-6 VMR 3-9 VMR 3-12 Part No. 321131 321132 321133 4 - 30 4 - 30 4 - 30 Frequency range MHz Equalization @ 47 MHz dB 6.0 9.0 12.0 Basic attenuation dB -1.0 -1.0 -1.0 Fixed return-path equalizers TYPE VMR 5-6 VMR 5-9 VMR 5-12 Part No. 321156 321157 321158 4 - 55 4 - 55 4 - 55 Frequency range MHz Equalization @ 47 MHz dB 6.0 9.0 12.0 Basic attenuation dB -1.0 -1.0 -1.0 Fixed return-path equalizers TYPE VMR 6-6 VMR 6-9 VMR 6-12 Part No. 321166 321167 321168 4 - 65 4 - 65 4 - 65 Frequency range MHz Equalization dB 6.0 9.0 12.0 Basic attenuation dB -1.0 -1.0 -1.0 18 Facts about HFA Distribution Amplifiers Technical Data - Mains powered TYPE HFA 602 HFA 603 HFA 604 Part No. 324602 324603 324604 Forward Path Frequency range MHz 47, 73 or 87 - 862 47, 73 or 87 - 862 47, 73 or 87 - 862 (depending on module) (depending on module) (depending on module) Gain adjustable dB 22 30 40 Attenuation dB 0 - 20 0 - 20 0 - 20 Noise figure dB < 8.5 (Typical 7.5) < 7.5 (Typical 6.5) < 7.0 (Typical 6.0) Linearity dB ± 1.0 ± 1.0 ± 1.0 Equalization dB 0 - 18 0 - 18 0 - 18 118 112 101 101 118 112 101 101 118 112 101 101 Output level 60 dB 3 order (DIN 45004B) 60 dB 3 order (DIN 45004A1) 60 dB CTB 1) 60 dB CSO 1) Return loss input dBµV dBµV dBµV dBµV HFA 602 (-1.5 dB/Octave) dB >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) Return loss output (-1.5 dB/Octave) dB >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) MHz 5-30, 5-55 or 5-65 5-30, 5-55 or 5-65 5-30, 5-55 or 5-65 (depending on module) (depending on module) (depending on module) Return path Frequency range Gain (adjustable) dB Linearity dB Return loss input passive -1.0/active 17.0 ± 1.0 ± 1.0 ± 1.0 (-1.5 dB/Octave) dB > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz Return loss output (-1.5 dB/Octave) dB > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz HFA 603 General Power supply type Power supply V/AC Mains powered Mains powered Mains powered 230 ± 10% 230 ± 10% 230 ± 10% Power consumption W 7.5 7.5 7.5 Shielding Efficiency VHF dB 100 100 100 Shielding Efficiency UHF dB Housing - Protection class Connectors 90 90 90 IP65 IP65 IP65 F-connectors F-connectors F-connectors Certification Impedance Ohm 75 75 75 Operation temperature range 0 C 0...+55 0...+55 0...+55 Weight kg 1.325 1.325 1.325 145 x 70 x 170 145 x 70 x 170 145 x 70 x 170 Dimensions (H x D x W) mm HFA 604 1) DIN/EN 50083 Part 3 CTBA (Composite trible beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Diplex filter modules TYPE MD 3047 MD 3047T MD 5573 MD 5573T Part No. 324681 324682 324685 324686 Frequency range (return path) MHz 5 - 30 5 - 30 5 - 55 5 - 55 Frequency range (forward path) MHz 47 - 862 47 - 862 73 - 862 73 - 862 dB - - 20 - - 20 pcs. 2 2 2 2 Testpoint Packing size 19 Facts about HFA Distribution Amplifiers Technical Data - Line powered TYPE HFA 622L HFA 623L HFA 624 L Part No. 324622 324623 324624 Forward Path Frequency range MHz Gain adjustable dB 22 30 40 Attenuation dB 0 - 20 0 - 20 0 - 20 Noise figure dB < 8.5 (Typical 7.5) < 7.5 (Typical 6.5) < 7.0 (Typical 6.0) Linearity dB ± 1.0 ± 1.0 ± 1.0 Equalization dB 0 - 18 0 - 18 0 - 18 118 112 101 101 118 112 101 101 118 112 101 101 Output level 60 dB 3 order (DIN 45004B) 60 dB 3 order (DIN 45004A1) 60 dB CTB 1) 60 dB CSO 1) HFA 622L 47, 73 or 87 - 862 47, 73 or 87 - 862 47, 73 or 87 - 862 (depending on module) (depending on module) (depending on module) Return loss input dBµV dBµV dBµV dBµV (-1.5 dB/Octave) dB >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) Return loss output (-1.5 dB/Octave) dB >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) >14 @ 40 MHz (Min. 10) MHz 5-30, 5-55 or 5-65 5-30, 5-55 or 5-65 5-30, 5-55 or 5-65 (depending on module) (depending on module) (depending on module) Return path Frequency range Gain dB Linearity dB Return loss input HFA 623L passive -1.0/active 17.0 ± 1.0 ± 1.0 ± 1.0 (-1.5 dB/Octave) dB > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz Return loss output (-1.5 dB/Octave) dB > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz > 14 @5 MHz to 65 MHz General Power supply type Power supply Line supply Line supply Line supply 24 - 60 24 - 60 24 - 60 V/AC Power consumption W 7.5 7.5 7.5 Shielding Efficiency VHF dB 100 100 100 Shielding Efficiency UHF dB 90 90 90 IP65 IP65 IP65 F-connectors F-connectors F-connectors Housing - Protection class Connectors Certification Impedance Operation temperature range 75 75 75 0 0...+55 0...+55 0...+55 C Weight kg Dimensions (H x D x W) HFA 624L Ohm mm 1.325 1.325 1.325 145 x 70 x 170 145 x 70 x 170 145 x 70 x 170 1) DIN/EN 50083 Part 3 CTBA (Composite trible beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels Diplex filter modules Return-path amplifier TYPE MD 6587 MD 6587T TYPE Part No. 324683 324684 Part No. Frequency range (return path) MHz 5 - 65 5 - 65 Frequency range (forward path) MHz 87 - 862 87 - 862 - - 20 Testpoint dB MHz Gain MHz 17 dB 20 TRP TYPE Part No. 416014 Part No. Max. current Dimensions (Height x Diameter) 5 - 65 Power inserter with F-con TYPE Power supply 324617 Frequency range Attenuation Line power supply MA 617 V/AC A mm 48 Frequency range 1.25 20 347001 MHz 5 - 2400 dB dB ≤ 0.5 ≤ 1.5 Max. current A 2.5 Power V 65 Through loss 5-862 MHz 1000-2150 MHz 60 x 100 TPI - 01 Facts about IFA Distribution Amplifiers Technical Data TYPE IFA 201 IFA 202 IFA 203 IFA 205 IFA 206 Part No. 339201 339202 339203 339205 339206 Forward Path 47 - 862 47 - 862 73 - 862 87 - 862 87 - 862 Gain @47 or 87 MHz/@862 MHz Frequency range dB 2...22 -4...15/1...20 -5...13/0...18 -3...17/2...22 -7...13/2...18 Noise figure dB < 5 (typical 4.5) < 5 (typical 4.5) < 6.5 (typical 5.5) < 8.5 (typical 7.5) < 8.5 (typical 7.5) Linearity dB ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 Slope dB 5.0 5.0 5 5.0 Equalizer dB 0 - 18 0 - 18 Outputs Output level 60 dB 3 order (DIN 45004B) 60 dB 3 order (DIN 45004A1) 60 dB CTB 1) 60 dB CSO 1) Return loss (-1.5 dB/Octave) MHz pcs dBµV dBµV dBµV dBµV dB 1 2 2 1 2 116.0 102.0 99.5 96.5 2 x 112.0 2 x 97.0 2 x 95.5 2 x 92.5 2 x 112.0 2 x 97.0 2 x 95.5 2 x 92.5 116.0 104.0 98.5 96.5 2 x 112.0 2 x 100.0 2 x 95.5 2 x 92.5 > 14 @47 MHz > 14 @47 MHz > 14 @73 MHz > 14 @87 MHz > 14 @87 MHz 5 - 30 5 - 30 5 - 55 5 - 65 5 - 65 0.5 4.0 4.0 1.0 4.0 Return path Frequency range Through loss MHz dB General Power supply 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10% Power consumption V/DC W 6.5 6.5 6.5 6.5 6.5 Shielding Efficiency VHF dB 65 65 65 65 65 Shielding Efficiency UHF dB 75 F-connector 75 F-connector 75 F-connector 75 F-connector 75 F-connector Connectors Certification Impedance Operation temperature range Weight Dimensions (H x D x W) Ohm 75 75 75 75 75 0 0...+50 0...+50 0...+50 0...+50 0...+50 C kg mm 0.475 0.475 0.475 0.475 0.475 65 x 50 x 175 65 x 50 x 175 65 x 50 x 175 65 x 50 x 175 65 x 50 x 175 1) DIN/EN 50083 Part 3 CTBA (Composite trible beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels 21 Facts about IFA Distribution Amplifiers Technical Data TYPE IFA 210 IFA 211 IFA 231 IFA 232 IFA 235 IFA 236 Part No. 339210 339211 339231 339232 339235 339236 Forward Path Frequency range 47 - 862 47 - 862 47 - 862 47 - 862 87 - 862 87 - 862 Gain @47 or 87 MHz/@862 MHz dB 0...20 0...20 -5...25/12...32 1...21/8...28 5...25/12...32 1...21/8...28 Noise figure dB < 5.0 (typical 4.5) < 5.0 (typical 4.5) < 6.5 (typical 6.0) < 6.5 (typical 6.0) < 7.0 (typical 6.5) < 7.0 (typical 6.5) Linearity dB ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 ± 1.0 Slope dB 7.0 7.0 7.0 5 Equalizer dB 0 - 18 0 - 18 0 - 18 0 - 18 Outputs Output level 60 dB 3 order (DIN 45004B) 60 dB 3 order (DIN 45004A1) 60 dB CTB 1) 60 dB CSO 1) Return loss (-1.5 dB/Octave) MHz pcs dBµV dBµV dBµV dBµV dB 1 1 1 2 1 2 112.0 104.0 94.5 90.5 112.0 104.0 94.5 90.5 116.0 104.0 97.5 93.5 2 x 112.0 2 x 100.0 2 x 93.5 2 x 89.5 116.0 104.0 97.5 93.5 2 x 112.0 2 x 100.0 2 x 94.5 2 x 90.5 > 14 @47 MHz > 14 @47 MHz > 14 @47 MHz > 14 @47 MHz > 14 @87 MHz > 14 @87 MHz 5 - 30 5 - 65 5 - 30 5 - 30 5 - 65 5 - 65 1.0 1.0 1.5 5.5 1.0 4.5 Return path Frequency range Through loss MHz dB General Power supply 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10% 230 ± 10% Power consumption V/DC W 3.0 3.0 6.5 6.5 6.5 6.5 Shielding Efficiency VHF dB 65 65 65 65 65 65 Shielding Efficiency UHF dB 75 F-connector 75 F-connector 75 F-connector 75 F-connector 75 F-connector 75 F-connector Connectors Certification Impedance Operation temperature range Weight Dimensions (H x D x W) Ohm 75 75 75 75 75 75 0 0...+50 0...+50 0...+50 0...+50 0...+50 0...+50 C kg mm 0.400 0.400 0.475 0.475 0.475 0.475 61 x 44 x 118 61 x 44 x 118 65 x 50 x 175 65 x 50 x 175 65 x 50 x 175 65 x 50 x 175 1) DIN/EN 50083 Part 3 CTBA (Composite trible beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels 22 Facts about ACB/ATB Sat IF Distribution Amplifiers Technical Data TYPE ACB 280 ATB 2200 Part No. 324280 300571 10 - 862 950 - 2150 86 - 862 950 - 2150 Forward Path Frequency range Terrestrial Satellite MHz MHz Gain Terrestrial Satellite dB dB - 2.0 21...28 20...28 20...28 Noise figure Terrestrial Satellite dB dB < 8.0 < 5.0 < 10.0 dB ± 1.0 ± 1.0 0 - 10 0 - 12 0 - 10 Linearity Attenuation Terrestrial Satellite dB dB Equalizer Terrestrial Satellite dB dB Inputs / Outputs pcs Output level Terrestrisk Sat - IM3-35 dBµV dBµV Isolation SAT/TV TV/SAT dB dB Return loss (-1.5 dB/Octave) dB -8.0 (fixed) -8.0 (fixed) 2/1 1/1 116.0 116.0 116.0 > 14 @47 MHz > 14 @ 86 MHz Return path Frequency range Through loss MHz 4 - 65 dB 1.5 General Power supply Power consumption V/AC V/DC 230 ± 10% 12 230 ± 10% 24 mA Connectors 250 (v. 15V) F-female F-female Certification Impedance Operation temperature range Weight Dimensions (H x D x W) ohm 75 75 0 0...+50 0...+50 C kg mm 1.4 1.4 100 x 62 x 185 100 x 68 x 187 1) DIN/EN 50083 Part 3 CTBA (Composite triple beat ratio) @ 60 dB IMR, CENELEC-raster 42 channels 23 Thinking one step ahead... Triax philosophy is customerorientation: In both our markets, TV-systems and enclosures, our objective is to save time and trouble for the installers, operators and distributors building their business on our products. Simplicity and support are key words, expressed both in products and in service. Our products offer more in performance and simplifying logic, and in our support customers have easy access to understandable, useful and competent answers. Innovative thinking, serviceoriented people and advanced technology has made Triax one of the leading European suppliers of both TV-systems and enclosures. AB.52.3.02 TRIAX A/S Bjørnkærvej 3 DK - 8783 Hornsyld Tel.: +45 76 82 22 00 Fax: +45 75 68 79 66 mail: [email protected] www.triax.com Tri We offer everything that can be expected from a professional supplier within these fields. Triax is of course ISO 9001 certified and delivers products according to all acknowledged local and international quality standards.