Convum
Transcription
Convum
Vacuum & Pressure Sensors Section C C Convum 175 Vacuum & Pressure Sensors Index 176 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors Index Technical Information Pressure Range 178 - 181 Output Type Maximum IP Rating Hysteresis Output Mode Adjustment Air, Non-Corrosive Gas 65 Air, Non-Corrosive Gas 65 Air, Non-Corrosive Gas 65 Air, Non-Corrosive Gas Output Setting Display Page Number Variable, 3 to 20% F.S. Trim Pot — 182 - 185 Variable, 100% F.S. Push Button LED Display 186 - 191 (Red) Variable, 100% F.S. Push Button LED Display 192 - 197 (Red) 65 Variable, 100% F.S. Push Button LED Display (Red / Green) 198 - 203 Air, Non-Corrosive Gas 40 — Trim Pot — 40 Variable, 100% F.S. Push Button Air, Non-Corrosive Gas 40 Fixed, < 2% F.S. Trim Pot 40 Variable, 100% F.S. Push Button LED Display 222 - 229 (Red) 65 Variable, 100% F.S. Push Button LED Display 230- 235 (Red) 65 — — Media MPS-1 0 to 10 bar 0 to -1 bar 0 to 0,9 bar (1) NPN / PNP With Analog MPS-2 0 to -1 bar -1 to 5 bar (2) NPN / PNP MPS-3 0 to 10 bar 0 to -1 bar 0 to 1 bar -1 to 5 bar (2) NPN / PNP Analog Option 0 to 10 bar 0 to -1 bar -1 to 5 bar (1) NPN / PNP MPS-31 MPS-6 0 to 10 bar 0 to -1 bar 0 to 1 bar (1) NPN / PNP or (1) Analog — 204 - 209 MPS-7 Remote Panel: Use with MPS-5,6,8 71: (2) NPN/PNP Analog Option 74: (1) NPN/PNP LED Display 210 - 217 (Red) MPS-8 0 to -1 bar -1 to 5 bar (1) NPN / PNP or (1) Analog 0 to -1bar -1 to 5 bar (1) NPN / PNP Air, Non-Corrosive Gas 0 to 10 bar 0 to -1 bar -1 to 5 bar (2) NPN / PNP Analog Option Fluid, Non-Corrosive to 316L or 630 SUS 0 to 10 bar 0 to -1 bar Analog — 218 - 221 MVS-201 MPS-3 Stainless MPS-5 Stainless Fluid, Non-Corrosive to 316L or 630 SUS — 236 - 239 P5V-SV -0,15 to -0,9 bar — Air, Non-Corrosive Gas Accessories — 20% of preset value — — 240- 241 242 - 243 177 04.10 www.parker.com/euro_pneumatic C Technical Information Solid State Sensors Difference Between Switch Output and Analog Output Type Introduction Electromechanical pressure sensors convert the applied pressure to an electrical signal. When pressure is applied, the diaphragm is deflected causing the diffused resistors to change resistance (piezoelectric effect), which yields an electrical signal proportional to the pressure change. Applications for pressure switches are numerous and important in today's high-tech manufacturing environment. Switch Output This is an NPN / PNP Open Collector transistor Output that “sinks” or “sources” the signal when the pressure switch point is achieved. The switch point is set by programming or potentiometer trimmer adjustment. 0 Silicon Diaphragm This type of sensor is used for air and non-corrosive gas applications. on h off on off H Sensor Module -1 bar Window Comparator Window Comparator provides two switch points at different pressures to activate the NPN / PNP open collector transistor outputs. Silicon Diaphragm Base 0 Pressure off A on on b off off -1 bar Stainless Steel Diaphragm This type of sensor is used for liquids, non-corrosive to 316L or 630 stainless steel. Analog Output An analog output provides an output voltage that is proportional and linear to the pressure measured by the sensor. This output signal provides continuous feedback to the analog card of the PLC. Semiconductor Pressure Element 20 Output (mA) Body SUS 316L 4 Output (Volts) Analog Output Stainless Steel Diaphragm SUS 316L or SUS 630 5 1 0 Pressure 178 0 Pressure Max. Rating 04.10 www.parker.com/euro_pneumatic Technical Information Difference Between NPN and PNP Output NPN PNP NPN type open collector transistor outputs are solid state circuits that provide sinking output capabilities. When the transistor is on, the current for the load flows into the transistor. This output “sinks” toward 0 VDC, 0 mA. PNP type open collector transistor outputs are solid state circuits that provide sinking output capabilities. When the transistor is on, the current for the load flows out of the transistor. This output “sources” toward 24 VDC, 125 mA. NPN Output (With Analog Output) PNP Output (With Analog Output) D1 Load ZD1 Tr2 (White) Out 2 Max. 125 mA 1K (Pink) Analog Option ZD3 Load Max. 125 mA ZD2 + – DC 10,8 V to 30 V DC 1 to 5 V (Brown) +V ZD1 ZD2 Tr1 Main Circuit (Black) Out 1 Tr1 Main Circuit D1 (Brown) +V (Black) Out 1 (Pink) Analog Or Tr D1 Load Load Tr1 + Main Circuit Main Circuit ZD1 DC – 10,8 V to 30 V Max. 125 mA (White) Out 2 Tr2 Max. 125 mA ZD2 DC 10,8 V to 30 V C Load PNP Output (With Reset IN) (Black) Out 1 Tr1 – (Blue) O V NPN Output (With Reset IN) (Pink) Digital IN Option Load DC 1 to 5 V Option 1K (Blue) O V (Brown) +V + (White) Out 2 ZD3 D1 Max. 125 mA Tr2 (Blue) O V Tr2 ZD1 ZD2 Or Tr (Brown) +V Max. 125 mA (Black) Out 1 (White) Out 2 Max. 125 mA + – DC 10,8 V to 30 V Load (Pink) Digital IN Option (Blue) O V Load Reset Input Option By sending a 5 VDC signal to the sensor, it is possible to automatically reset the sensor to ambient zero when small fluctuations in the system or atmosphere influence the beginning reference point. Fluctuation H Negative Pressure Digital Set H OK NG IN Negative OK Pressure OK IN IN IN Flashing display of AL is displayed when the digital IN signal is entered. 179 04.10 www.parker.com/euro_pneumatic Technical Information Output Modes Repeatability Switch Point with Hysteresis Settings The repeatability refers to the sensor’s ability to provide the same output with consecutive applications of the same pressure input. Reading Repeatability This output mode provides one switch point (H) and a hysteresis pressure adjustment. When the switch point pressure is achieved, the output (NPN / PNP) is activated if normally open or deactivated if normally closed. Typically, this mode is used for pressure confirmation. For positive pressure applications, this operating mode does not provide any output or alarms beyond the switch point in the case of excessive pressures. The hysteresis setting (h) is the difference in pressure below the switch point pressure which controls the on / off status of the output. + P1 Pressure 0 on h Repeatability is represented as a percentage of the full scale value of the sensor. All Parker / Convum sensors are rated ± 0,2% F.S. P1 would be represented as 10 bar x 0,002 = ± 0,02 bar. on off off H Accuracy -1 bar Window Comparator Setting This output mode provides two switch points (A) and (b) that control the output signals (NPN / PNP) between the two pressures. This creates a “window” that the sensor can provide an output and is sometimes referred to as “high / low” setting. The window comparator Mode provides an output or alarm when pressures exceed the upper limit. 0 on on b off Display Resolution The least possible unit increment shown on the display. IP Ratings IP40 - Protected against solid foreign objects of 0,04" (1 mm) and greater. Non-protected against the penetration of liquids. IP65 - Dust tight. Protected against water jets. IP67 - Dust tight. Protected against the effects of temporary immersion water. off A The PERCENTAGE difference between the true value and that indicated by an instrument is the measure of the instrument’s accuracy. It is expressed as a percentage of the full-scale value of the reading according to the type of instrument. off -1 bar Pressure Unit Table Units Units Pa bar PSI kgf/cm2 atm mm H2O in H2O mm Hg in Hg Pa 1 10-5 0,145x10-3 1,0197x10-5 0,987x10-5 0,10197 0,402x10-2 0,750x10-2 0,295x10-3 bar 105 1 14,5038 1,01972 0,98692 10197,16 401,46 750,062 29,53 PSI 6894,76 0,06895 1 0,07031 0,6805 703,07 27,68 51,715 2,036 kgf/cm 2 98066,5 0,9807 14,2233 1 0,96784 10000 393,70 735,56 28,96 atm 1,013x10-5 1,01325 14,696 1,03323 1 10332 406,77 760 29,92 mm H2O 9,807 0,098x10-3 0,00142 0,0001 0,097x10-3 1 0,0394 0,07355 0,29x10-2 in H2 O 249,09 0,249x10-2 0,0361 0,00254 0,246x10-2 25,4 1 1,868 0,07355 mm Hg 133,322 0,00133 0,01934 0,00136 0,00132 13,5951 0,535 1 0,0394 in Hg 3386,4 0,03378 0,4912 0,0345 0,03353 345,32 13,589 25,4 1 180 04.10 www.parker.com/euro_pneumatic Technical Information Pressure Value Display Mode. Displays Pressure for a specific time period and then updates for next time period Output 1 Output 2 Time Range for Pressure Value Display Mode Output 3 Value Setting for Pressure Value Display Mode Output 4 Display Peak Value over selected time range Output Normally Closed (Passing) Display Bottom Value over selected time range Output Normally Open (Non-Passing) Display Difference over selected time range Pressure Units (Pascal). Negative Units for Vacuum Sensors Display Function Mode. On/Off Pressure Units (Bar). Negative Units for Vacuum Sensors Display Function. Selects display types. Pressure Units (in.Hg). Negative Units for Vacuum Sensors Display blinks pressure when Output 1 is Passing Normal when Output 1 is Non-Passing Pressure Units (in.Hg). Negative Units for Vacuum Sensors Display blinks pressure when Output 2 is Passing Normal when Output 2 is Non-Passing Pressure Units (kgf/cm ). Negative Units for Vacuum Sensors 2 Display shows pressure when Output 1 is Passing Display shows special screen when Non-Passing Pressure Units (PSI) Display shows pressure when Output 2 is Passing Display shows special screen when Non-Passing Easy Mode. Sensor will only allow changes to set points Select Switch Output setting for MPS-31 Off, or Energy Saving Display; reduces current consumption of Sensor Color Setting for MPS-31 On MPS-4, Port Reference Selection Hysteresis Mode. Select Hysteresis Set Point and Hysteresis Range MPS-4, Display change of B port to A port static Windows Comparative Mode Select High and Low Set Point MPS-4, Display change of A port to B port static Hysteresis Mode Set Point. Output 1 MPS-4, Display change of A port to change of B port Hysteresis Mode Set Point. Output 2 MPS-7, Pressure Range Selection Vacuum Hysteresis Mode. Hysteresis Range Output 1 MPS-7, Pressure Range Selection Low Pressure Hysteresis Mode. Hysteresis Range Output 2 MPS-7, Pressure Range Selection Positive Pressure Windows Comparative Mode Low Set Point Output 1 MPS-7, Pressure Range Selection Compound Pressure Windows Comparative Mode High Set Point Output 1 MPS-7, Energy Savings Mode, reduces current consumption Windows Comparative Mode Low Set Point Output 2 MPS-7, Peak Surveillance Windows Comparative Mode High Set Point Output 2 Digital Input Sensors Only. Digital Input Mode for remote Zero reset of sensors Automatic Teach Mode. Automatically sets Outputs 1 and 2 while cycling system. Output 1 set to Hysteresis Mode, Output 2 set to Window Comparative Mode Digital Input Auto Surveillance Mode On/Off. Set after Automatic Teach Digital Channel Auto Surveillance based on cycles times. Provides output if Peak Value is not obtained in a specified number of cycles. (1-100) MPS-7 Scan Mode. Sensor scans and displays each channel for 3 sec. Locked. Sensor programs cannot be changed Display Refresh Setting. Display updates from 0,1 to 1 sec. 0,3 sec factory set. Does not affect Sensor Response Time Output Response Time. Multiples the sensor response time. Increases sensor response time. (Anti-chatter Mode) Unlocked. Sensor programs can be changed Zero Reset 181 Sets Sensors reference point to current atmospheric conditions 04.10 www.parker.com/euro_pneumatic C Vacuum & Pressure Sensors MPS-1 Features MPS-1 • Pressure Ranges: Vacuum .................................... 0 to -1 bar Positive Pressure ................... 0 to 10 bar • Sensor Outputs 1 Normally Open NPN or PNP Open Collector Transistor Output; 30 VDC, 125 mA 1 Analog 1 to 5 VDC • Switch Output Adjusted with Potentiometer 3-Turn Trimmer • Switch Hysteresis Adjusted with Potentiometer 3/4 Turn Trimmer • Output Response Time Less Than 2,5 Milliseconds Output MPS-V1G-PC PNP 0 to -1 bar MPS-P1G-PC PNP 0 to 10 bar MPS-V1E-PC PNP 0 to -1 bar MPS-P1E-PC PNP 0 to 10 bar • IP65 Rated and CE Marked Pressure Range • Air and Non-Corrosive Gases Switch Output Output Modes The MPS-1 Series Sensor has two outputs, one open NPN or PNP switch output and one analog output. The Hysteresis Range (h) controls the output signal below the Switch Point (H). The Pressure Output Signal is a 3 turn trimmer that sets the switch point of the output. The hysteresis adjustment is a 3/4 turn trimmer to control the output signal 3 to 20% below the pressure output signal. The Analog Output is a 1 to 5 VDC signal calibrated to the pressure scale of the sensor. 0 on h off on off H -1 bar Analog Output Analog Output Output (Volts) Model Number 5 1 0 182 0 Pressure Max. Rating 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-1 Model Number Index MPS - V 1 G - P Pressure Range V 0 to -1 bar P 0 to 10 bar Port Size G 1/8" BSPP / M5F E Flange / M5F C Circuit N NPN Sinking Output P PNP Sourcing Output Electrical Connector C M8 4-Pin C MPS-L1G-PC MPS-V1E-PC Specifications Media Pressure Port Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Air and Non-Corrosive Gases G: 1/8" BSPP, E: Flange Mount with M5 Female V: 5 bar, P: 15 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH 4-Pin, M8 Connector with Built-in LED Power Supply 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection Analog Output 1 to 5 VDC ±0,04, Accuracy Linear 0,5% F.S. Switch Output N.O., Switch Output Mode with Hysteresis Adjustment Output Circuit Switch Output Setting H Hysteresis Setting h NPN (Sinking), PNP (Sourcing) Open Collector Transistor 30 VAC, 80 mA 3-Turn Trimmer 3/4-Turn Trimmer (3 to 20% of Switch Output Setting) Response Time < 2,5 ms Repeatability ±1% F.S. Thermal Error General Protection Current Consumption Spike Protection Dielectric Strength Insulation Resistance Vibration Resistance Shock Resistance Material Mass 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP65 or IP40, EMC Rating : EN55011 Class B, EN50082-2 < 20 mA 400 VP, 1 µs 1000 VAC, 1 min. > 100 Mohms at 500 VDC 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 100 G, XYZ Housing: Polycarbonate, Pressure Port: Zinc Die-cast 30 g 183 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-1 Output Setting ! Switch Output Setting The MPS-1 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Potentiometer for the Switch Point Pressure and Hysteresis Range is sensitive. Excessive force or exceeding the limits of the trimmers may cause damage. The Switch Point of the output signal is adjusted with a 3-turn potentiometer trimmer (S) (S). To set the switch point pressure, rotate the trimmer clockwise to raise the switch pressure and rotate the trimmer counter clockwise to lower the switch pressure. Cautions Operating Environment S • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. H Hysteresis Setting Installation The Hysteresis setting is a 3/4 - turn potentiometer trimmer with a range of 3% to 20% below the switch point (S) (S). Rotate the Hysteresis trimmer (H) clockwise to increase the Hysteresis range and rotate the trimmer counter clockwise to lower the Hysteresis range (h) (h). A separate pressure gauge is necessary to accurately adjust these values. For best results, set the switch point (H) of the output signal before adjusting the hysteresis range. For fine tuning the hysteresis range, re-adjust the switch point (S) of the output signal. • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using the metal mounting base. • To achieve IP65 rating, connect the o-ring and barb to a normal environment with a 2 mm I. D. tube and install screw as shown. S H Barb Coupling O-Ring S H -INCLUDED- Wiring Diagram Screw Internal Circuit Pin # 1 Brown:24 VDC 2 White: Analog 1 to 5 VDC Output 3 Blue: 0 VDC 4 Black: NPN / PNP Open Collector Output H 1 1 2 2 4 H 4 S NPN (Sinking) Sensor Male Pin Out 4 3 3 S 3 PNP (Sourcing) 2 1 184 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-1 Dimensions M5Fx5 G M3Fx4 2 Places LED S 1/8" Male M8, 4-Pin M8 21,2 H 8 G1/8M 45 9 15,7 E M3Fx5 4 Places Flange Mount M4F 2 Places M3Fx4 2 Places LED S M5Fx5 M8, 4-Pin 19 13 8 21,2 24,7 M8 H C 10 9 44 1,5 15,7 9 Accessories 44 8 Flange Bracket for V1E Type 19 (Not included) = ACCMPS-1E Ø 4,5 4 Places 33 31 0,8 30 7,4 16 3,2 Cables 7,2 CB-M8-4P-2M Ø5 Ø 9,7 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 22 5m 185 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-2 Features MPS-2 • Pressure Ranges: Vacuum .................................... 0 to -1 bar Positive Pressure ................... 0 to 10 bar • Sensor Outputs: 2 NPN or PNP Open Collector Transistor Output , 30 VDC, 125 mA • Switch Point and High-low Programming • 4 Selectable Units of Measure (mmHg, -bar, -kPa, inHg) (kgf/cm2, PSI, bar, kPa) • Output Response Time Less Than 2,0 Milliseconds • IP65 Rated and CE Marked Model Number Output MPS-V2G-PC PNP 0 to -1 bar MPS-P2G-PC PNP 0 to 10 bar • Air and Non-Corrosive Gases Pressure Range • Error Message Switch Output Output Modes 0 The MPS-2 Series Sensor has two independent NPN or PNP open collector output signals. The Switch Output Mode has a switch point programmed by the user at a specified pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). The Window Comparator Mode provides two Switchpoint Settings (A) and (b) that control the output signals (NPN / PNP) between two pressures. This is referred to as the “High / Low” setting. on h off on off H -1 bar Window Comparator Output 0 off A on on b off off -1 bar 186 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-2 Model Number Index MPS - V 2 G - P Pressure Range V 0 to -1 bar P 0 to 10 bar Port Size G 1/8" BSPP M5 M5 Female* Circuit N NPN Sinking Output P PNP Sourcing Output * Din Rail Only C – Din Rail Blank Without R* With Electrical Connector C M8 4-Pin * M5 Port Size Only C MPS-V2G-PC MPS-P2M5-PGR Specifications Pressure Range Vacuum (V) Units of Measure Display Resolution kPa: 0,1 Media Air and Non-Corrosive Gases Pressure Port G: 1/8" BSPP, M5: M5 Female Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Display Display Refresh Positive (P) MPa: 0,001 V: 5 bar, P: 15 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH C: 4-Pin, M8 Connector 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 3-Digit, 7-Segment LED 0,1 to 3,0 sec. (Factory set at 0,1) Output Circuit NPN (Sinking) or PNP (Sourcing) Output, Open Collector Transistor 30 VDC, 125 mA Switch Output 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator Output Modes Response Time Repeatability Thermal Error General Protection Insulation Resistance Vibration Resistance Shock Resistance Material Mass Hysteresis or Window Comparator < 2 ms, with Programmable Increments 32, 128, 1024 ms ± 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP65 or IP40, CE Rating, EMC-EN55011 Class B, EN 50082-2 > 100 Mohms at 500 VDC 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Housing: Polycarbonate, Pressure Port: Zinc Die-cast 45 g 187 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors Wiring Diagram Pin # 1 Brown:24 VDC 2 White: NPN / PNP Open Collector Output 3 Blue: 0 VDC 4 Black: NPN / PNP Open Collector Output MPS-2 Sensor Male Pin Out 4 2 3 1 Internal Circuit NPN PNP 1 1 2 2 4 ! 4 3 3 NPN Sinking PNP Sourcing Cautions The MPS-2 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install as shown using the metal mounting base. • To achieve IP65 rating, connect the o-ring and barb as shown to a normal environment with a 2 mm I. D. tube. Ambient Air Inlet Port 2 1 Barb O-Ring Coupling –INCLUDED– Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. 2 1 Error Messages Display 188 Description Solutions Err Zero Reset Error 3% of F.S. Reset Zero Below Er1 System Error (Internal) Contact Factory Er2 Auto Teach Mode Error Restart Function CE1 Over current of Output 1 Load current exceeds CE2 Over current of Output 2 maximum 125 mA. FFF –FF Applied pressure exceeds pressure range Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-2 Dimensions G 1/8" Male M8, 4-Pin 2 1 M5Fx0,8 44 M3Fx4 Vent Port 25 14 12,5 5,7 8 G1/8M Din Rail M5 Female 59 9 C 16 3,8 61 Grommet 2 1 M5Fx0,8 M3Fx4 Vent Port 25 14 12,5 5,7 10 16 88 189 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-2 See page 181 for Symbol Explanation 1 Hold Press 2 2 1 4 Press Press 1x 2 1 Output Set Open or Closed Selecting Units of Measure Easy Mode Activation 1x 2 1 2x 5 Press Output 1 Setting Hysteresis Mode 3 3x 2 1 Press Output Mode 1 Hysteresis or Window Comparator Output 2 Setting Hysteresis Mode 4x 2 1 6 Press Output Mode 2 Hysteresis or Window Comparator 5x 2 1 Automatic Teach Mode & Auto Surveillance Vacuum Cycle Window Comparator Mode Low Window Comparator Mode Low High 7 Press High 6x 2 1 10 Hold Press 8 Press Display Refresh Settings / Output Response Time Interval 11 Press 2 1 Unlock 7x 2 1 Hold Press 2 1 Lock Release Cycle 1x Display Peak Value Bottom Value or Their Difference Press 2 1 1x 2 1 9 Press 8x 2 1 12 Press Special Display Features for 3 Seconds Zero Reset 2 1 2 1 Bottom Value Peak Value 190 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-2 Accessories Cables CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m C 32 CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 Din Rail MPS-ACCK4 13 88 10 191 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Features MPS-3 • Pressure Ranges: Vacuum ................................... 0 to -1 bar Positive Pressure .................. 0 to 10 bar • Sensor Outputs: 2 NPN or PNP Open Collector Transistor Output, 30 VDC, 125 mA Optional Analog 1 to 5 VDC • Switch Point and High-low Programming • 4 Selectable Units of Measure (mmHg, -bar, -kPa, inHg) (kgf/cm2, PSI, bar, kPa) • Output Response Time Less Than 2,0 Milliseconds • IP65 Rated and CE Marked Model Number Output MPS-V3G-PC PNP Pressure Range 0 to -1 bar MPS-V3G-PG PNP 0 to -1 bar MPS-P3G-PC PNP 0 to 10 bar MPS-P3G-PG PNP 0 to 10 bar Output Modes The MPS-3 Series Sensor has two independent NPN or PNP open collector output signals. An analog output is optional. The Switch Output Mode has a switch point programmed by the user at a specific pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). The Window Comparator Mode provides two Switchpoint Settings (A) and (b) that control the output signals (NPN / PNP) between two pressures. This is referred to as the “High / Low” setting. The optional Analog Output Signal is calibrated to the pressure scale of the sensor. • Air and Non-Corrosive Gases • Error Message Switch Output 0 on h off on off H -1 bar Window Comparator Output 0 off A on on b off off -1 bar 192 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Model Number Index MPS - V Pressure Range V 0 to -1 bar P 0 to 10 bar Port Size G 1/8" BSPP 3 G - P C Circuit N NPN Sinking Output P PNP Sourcing Output Electrical Connector C 4-Pin, M8 G Grommet (2m) C MPS-V3G-PC MPS-V3G-PG Specifications Pressure Range Units of Measure Display Resolution Media Pressure Port Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Display Display Refresh Output Circuit Switch Outputs Output Modes Output Response Time Repeatability Thermal Error General Protection Current Consumption Vibration Resistance Shock Resistance Material Mass Vacuum (V) Positive (P) kPa: MPa: 0,1 0,001 Air and Non-Corrosive Gases G: 1/8" BSPP Female V: 10 bar, P: 15 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH C: 4-Pin, M8 Connector, G: Grommet Open Lead 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 3-Digit, 7-Segment LED 0,1 to 3,0 sec. (Factory set at 0,1) NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator Hysteresis or Window Comparator < 2 ms with Programmable Increment 32, 128, 1024 ms (XS2H2-32, 256, 512 ms) ± 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP65 or IP 40, CE Rating, EMC-EN55011 Class B, EN 50082-2 < 55 mA 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Housing: Polycarbonate, Pressure Port: Zinc Die-cast 45 g 193 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Open Collector Wiring Pin # 1 Brown:24 VDC 2 White: NPN / PNP Open Collector Output 3 Blue: 0 VDC 4 Black: NPN / PNP Open Collector Output Sensor Male Pin Out 4 3 ! 2 1 Cautions The MPS-3 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install as shown using the metal mounting bracket. • To achieve IP65 rating, connect the o-ring and barb as shown to a normal environment with a 2 mm I. D. tube. Pipe Plug Ambient Air Inlet Port Barb O-Ring Coupling –INCLUDED– Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. Error Messages Display 194 Description Solutions Err Zero Reset Error 3% of F.S. Reset Zero Below Er1 System Error (Internal) Contact Factory Er2 Auto Teach Mode Error Restart Function CE1 Over current of Output 1 Load current exceeds CE2 Over current of Output 2 maximum 125 mA. FFF –FF Applied pressure exceeds pressure range Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Dimensions G 1/8" Female 4,5 27 30 20 8,5 13 30 1 20 2 1 2 6,7 12,2 1/8" BSPP 4 M3 Venting Port M8 Grommet Lead C 4-Pin Connector MPS-ACCK1 Mounting Brackets (Included) 14 14 7 5,5 25 27 28 20 20 20 20 30 43 Ø 4,5 Ø 4,5 13 6 35 22 195 5,5 13 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 See page 181 for Symbol Explanation 1 Hold Press 2 1x Press 2x 4 Press 1x 3 Press 4x Output Mode 1 Hysteresis or Window Comparator Output Set Open or Closed Selecting Units of Measure Easy Mode Activation 5 Press Output Mode 2 Hysteresis or Window Comparator 3x 6 Output 1 Switch Point Setting Output 2 Switch Point Setting Hysteresis Mode Hysteresis Mode Press 5x Automatic Teach Mode & Auto Surveillance Vacuum Cycle Window Comparator Mode Low High 7 Press High 6x 8 Press 7x Display Refresh Settings / Output Response Time Interval 10 Hold Press Release Cycle Window Comparator Mode Low 1x Lock Hold Press 9 Press Display Peak Value Bottom Value or Their Difference 1x Unlock 11 Press 1x Press 1x 8x Special Display Features 12 Press for 3 Seconds Zero Reset Bottom Value Peak Value 196 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Accessories Cables CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 C CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 MPS-ACCH7 Panel Mounting Bracket 43,8 40 40 Knockout 33,4 1 36 (+0.5, -0.2) 2 36 (+0.5, -0.2) 197 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors Features MPS-31 Red MPS-31 Green Display • Pressure Ranges: Vacuum ................................... 0 to -1 bar Positive Pressure .................. 0 to 10 bar • Sensor Output: 1 NPN or PNP Open Collector Transistor Output , 30 VDC, 125 mA • Switch Point and High-low Programming • 4 Selectable Units of Measure (mmHg, -bar, -kPa, inHg) (kgf/cm2, PSI, bar, kPa) • Output Response Time Less Than 2,0 Milliseconds • IP65 Rated and CE Marked Model Number Output Pressure Range MPS-V31G-PC PNP 0 to -1 bar MPS-V31G-PG PNP 0 to -1 bar MPS-P31G-PC PNP 0 to 10 bar MPS-P31G-PG PNP 0 to 10 bar Output Modes The MPS-31 Series Sensor has one independent NPN or PNP open collector output signal. The Switch Output Mode has a switch point programmed by the user at a specific pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). The Window Comparator Mode provides two Switchpoint Settings (A) and (b) that control the output signals (NPN / PNP) between two pressures. This is referred to as the “High / Low” setting. • Air and Non-Corrosive Gases • Error Message Switch Output 0 on h off on off H -1 bar Window Comparator Output 0 off A on on b off off -1 bar 198 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-31 Model Number Index Bold Items Are Standard Pressure Range V 0 to -1 bar P 0 to 10 bar R -1 to 5 bar MPS - Port Size G 1/8" BSPP V 31 G - P C Circuit N NPN Sinking Output P PNP Sourcing Output Electrical Connector C 4-Pin, M8 G Grommet (2 m) C MPS-V31G-PG Mounting Bracket MPS-ACCK1 Included with Sensors. MPS-V31G-PC Specifications Pressure Range Units of Measure Display Resolution Media Pressure Port Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Display Display Refresh Vacuum (V) kPa: Positive (P) 0,1 MPa: Compound (R) 0,001 kPa: 1 Air and Non-Corrosive Gases G: 1/8" BSPP V: 10 bar, P: 15 bar, R: 10 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH C: 4-Pin, M8 Connector, G: Grommet Open Lead 10,8 to 26,4 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 3-Digit, 7-Segment LED 0,1 to 3,0 sec. (Factory set at 0,1) Output Circuit NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA Switch Output Output Signal, NPN or PNP, Normally Open or Closed, LED Indicator Output Modes Output Response Time Repeatability Thermal Error General Protection Current Consumption Vibration Resistance Shock Resistance Material Mass Hysteresis or Window Comparator < 2 ms, 32, 256, 512 ms Programmable (Factory set 2 ms) ± 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP65 or IP40, CE Rating, EMC-EN55011 Class B, EN 50082-2 < 70 mA 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Housing: Polycarbonate, Pressure Port: Zinc Die-cast 48 g 199 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors Open Collector Wiring Sensor Male Pin Out Pin # 1 2 3 MPS-31 Brown: 24 VDC Black: NPN/PNP Output 1 Blue: 0 VDC 4 2 3 1 Internal Circuit (Brown) +V D1 (Black) Out 1 Tr1 ZD1 (Blue) OV LOAD Max. 125mA Main Circuit Main Circuit D1 +DC - 10.8V to 30V Tr1 (Brown) +V ZD1 (Black) Out 1 (N.O.) LOAD Max. 125mA +DC - 10.8V to 30V (Blue) OV NPN ! Cautions The MPS-31 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. PNP Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install as shown using the metal mounting bracket. • To achieve IP65 rating, connect the o-ring and barb to a normal environment with a 2 mm I. D. tube. Pipe Plug Ambient Air Inlet Port Barb O-Ring Coupling –INCLUDED– Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. Error Messages Display Err 200 Description Solutions Zero Reset Error 3% of F.S. Reset Zero Below Er1 System Error (Internal) Contact Factory CE1 Over current of Output 1 Load current exceeds FFF –FF Applied pressure exceeds pressure range Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-31 Dimensions G 1/8" Female 27 4,5 30 20 8,5 13 20 30 6,7 12,2 4 1/8" BSPP Grommet Lead C M3 Venting Port M8 4-Pin Connector MPS-ACCK1 Mounting Brackets (Included) 14 14 7 5,5 25 27 28 20 20 20 20 30 43 Ø 4,5 Ø 4,5 13 6 35 22 201 5,5 13 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-31 See page 181 for Symbol Explanation 1 Press for 3 Seconds Begin Programming Operating Output Mode Or Press Select Units of Measure Output Normally Open or Closed 1x to Proceed Wait 3 Seconds Or Press 1x to Proceed Wait 3 Seconds Display Refresh Or Press 1x to Proceed Wait 3 Seconds Or Press 1x to Proceed Wait 3 Seconds Output Response Selection Display Color Choices Red and / or Green, Energy Save Or Press Or Press 1x to Proceed Wait 3 Seconds 1x to Return Output On Off Red Green Wait 3 Seconds Green Red Red Red Green Green 2 Press 1x 3 Switch Output Setting and Low Setting 4 Hold Press Hold Press 1x 1x Will Display for 1 Second Hysteresis Mode Low 1x Hysteresis Setting and High Setting Will Display for 1 Second Window Comparator Mode Press Hysteresis Mode Window Comparator Mode Lock 5 Unlock Zero Reset High Wait 5 Seconds Wait 5 Seconds 202 Press for3 Sec. 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-31 Accessories Cables CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m C 32 CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 MPS-ACCH7 Panel Mounting Bracket 43,8 40 40 Knockout 33,4 36 (+0,5, -0,2) 36 (+0,5, -0,2) 203 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 Features Model Number Output Pressure Range MPS-V6G-PC PNP 0 to -1 bar MPS-V6G-AG Analog 0 to -1 bar MPS-V6G-AGE Analog 0 to -1 bar MPS-P6G-PC PNP 0 to 10 bar MPS-P6G-AG Analog 0 to 10 bar MPS-P6G-AGE Analog 0 to 10 bar Output Modes The MPS-6 Series Sensor is compact and lightweight with NPN or PNP open connector switch output or analog output capabilities. The sensor can be used as a stand alone unit or in combination with the MPS-7 series display. The MPS-6 Switch Output unit provides one open and closed output for the same switch point. The MPS-6 Analog Output unit provides analog output 1 to 5 VDC. Analog output is required for use with the MPS-7 display. • Pressure Ranges: Vacuum ................................... 0 to -1 bar Positive Pressure .................. 0 to 10 bar • Sensor Outputs: 1 Open and 1 Closed NPN or PNP Open Collector Transistor Output 30 VDC, 125 mA 1 Analog Output 1 to 5 VDC • Switch Point 2/3 Trimmer • Fixed Hysteresis 2% • Output Response Time Less Than 1 Millisecond • Analog Output Type Compatible with MPS-7 Display • IP40 Rated and CE Marked • Air and Non-Corrosive Gases Switch Output 0 on S Fixed 2% off on off -1 bar Analog Output Output (Volts) MPS-6 5 1 0 204 0 Pressure Max. Rating 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 Model Number Index MPS - V Pressure Range V 0 to -1 bar P 0 to 10 bar Port Size G 1/8" BSPP & M5 Female T 6 mm Tube Stud 6 G - P C Output Circuit N NPN Output P PNP Output A Analog (1 to 5 VDC)* Electrical Connector C 4-Pin, M8 G Grommet (2 m) GE 2 m Grommet Clip Conn.* * With Grommet GE Only * Use with MPS-7 Series Display, with Analog Only C MPS-P6G-PC MPS-P6G-AG MPS-V6T-PG MPS-P6G-AGE Specifications Media Air and Non-Corrosives Gases Pressure Port G: 1/8" BSPP Male, T: 6 mm Tube Stud Proof Pressure V: 5 bar, P: 15 bar Operating Temperature 0 to 50 °C Storage Temperature -10 to 60 °C Humidity 35 to 85% RH Electrical Connection C: 4-Pin, M8 Connector G: Grommet Lead GE: Clip Type for use with MPS-7 Display Power Supply 10,8 to 30 VDC, Ripple Vp-p 10% max., Reverse Voltage Protection Switch Output 1 Output Signal Open and Closed, NPN or PNP, 30 VDC, 125 mA Linear Output Analog Output 1 to 5 VDC Switch Point Setting 2/3 Turn Trimmer Hysteresis Setting < 2% of F.S. Output Response Time <1 ms Repeatability <0,2% F.S. Thermal Error 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) General Protection IP40, CE Rating EN55011 Class B, EN50082-2 Current Consumption < 20 mA Spike Protection 400 VP, 1 µs, Surge Protection Dielectric Strength 1000 VAC, 1 min. Insulation Resistance > 100 Mohm at 500 VDC Vibration Resistance 10 to 55 Hz, 0,75 mm Amplitude, XYZ, 2 hrs. Shock Resistance 100 G, XYZ Material Housing: Polycarbonate, Pressure Port: Zinc Die-cast Mass T Port: 7 g, N, R, G Port: 25 g 205 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 Open Collector Wiring Analog Wiring Pin # 1 2 3 4 Pin # 1 2 3 4 24 VDC NPN / PNP Open Collector Output N. C. 0 VDC NPN / PNP Open Collector Output N. O. 4 Sensor Male Pin Out Brown: White: Blue: Black: 24 VDC LED In 5 VDC 0 VDC Analog 1 to 5 VDC 2 D1 3 Main Circuit Brown: White: Blue: Black: 1 Tr1 (Brown) +V ZD1 (Black) Out 1 (N.O.) Tr2 ZD2 (White) Out 2 (N.C.) LOAD Max. 125mA +DC – 10.8V to 30V LOAD Max. 125mA (Blue) OV Internal Circuit NPN Open Collector LED D1 Main Circuit Main Circuit (Brown) +V (White) Input for LED lighting (5VDC) (Black) Analog 1 5V Output +DC - 10.8V to 30V Tr1 (Brown) +V ZD1 (Black) Out 1 (N.O.) Tr2 ZD2 (White) Out 2 (N.C.) LOAD Max. 125mA +DC – 10.8V to 30V LOAD Max. 125mA (Blue) OV (Blue) OV Analog ! Cautions The MPS-6 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. PNP Open Collector Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using the metal mounting bracket. Trimmer Adjustment Rotate the potentiometer trimmer to increase or decrease pressure switch point output. Excessive force or exceeding the limits of the trimmers may cause damage. Switch Point Trimmer – 206 + 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 Dimensions G 1/8" Male, M5 Female, Grommet 16 Switch Point Trimmer Output LED 26,3 1/8" BSPP Output LED 2m 20 or M5–6 T6 Tube Stud, Grommet 10 34,1 16 19,8 C 2m 20 6 mm Tube 10 G 1/8" Male, M5 Female, M8, 4-Pin 16 26,3 1/8" BSPP Switch Point Trimmer Output LED Output LED 20 or T6 M5–6 Tube Stud, M8, 4-Pin 15 34,1 16 Switch Point Trimmer Output LED 19,8 20 6 mm Tube 15 G or T6 Grommet Clip Connector 16 1/8" BSPP 26,3 AMP 5-Pin Connector 171822-5 20 M5–6 2m 207 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 Accessories Cables CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 CB-M8-4P-5M-90 Ø 9,7 Ø 9,7 19 10,7 Ø5 5m 22 208 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-6 C 209 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 Features MPS-7 • One Display with Output Programming Capability for MPS-5, 6, or 8 Analog Sensors • Displays Pressure and Converts Analog Signal from Remote Sensor to NPN or PNP Open Collector Transistor Output, 30 VDC, 125 mA • Compatible with 1 to 4 Remote Sensors • MPS-71 Response Time Less Than 2,0 Milliseconds • MPS-74 Response Time Less Than 5 Milliseconds • IP40 Rated and CE Marked Model Number Output MPS-71E-NC NPN MPS-71E-PC PNP MPS-71E-NG NPN MPS-71E-PG PNP MPS-74E-NG NPN MPS-74E-PG PNP MPS-71E-PG Control with Remote MPS-P6G-AGE Shown Output Modes The MPS-7 is a central display and control for remote MPS-5, 6, 8 analog sensors. Each remote sensor supplies an analog signal to a specific channel on the MPS-7 which is converted to an open connector output “NPN / PNP”. The Switch Output Mode has a switch point programmed by the user at a specified pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). The Window Comparator Mode provides two Switchpoint Settings (A) and (b) that control the output signals (NPN / PNP) between two pressures. This is referred to as the “High / Low” setting. Switch Output 0 on h off on off H -1 bar Window Comparator Output 0 off A on on b off off -1 bar 210 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 Model Number Index MPS - 7 1 E - N Number of Remote Sensors 1 1 Sensor 4 4 Sensors C Circuit N NPN Output Sinking P PNP Output Sourcing Electrical Connector C* 4-Pin, M8 G Grommet (2 m) * Available on MPS-71 only. C MPS-74E-NG MPS-71E-PG Mounting Bracket Included with Sensors. Specifications Remote Pressure Range Units of Measure Display Resolution Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Vacuum (V) Positive (P) kPa: MPa: 0,1 0,001 See Remote Sensor Specifications 0 to 50 °C -10 to 60 °C 35 to 85% RH G: Grommet Open Lead, C: M8 Connector Power Supply 10,8 to 30 VDC, Ripple (P-P) 10% Max., Reverse Voltage Protection Display MPS-71: 3-Digit, 7-Segment LED, MPS-74: 4-Digit, 7-Segment LED Display Refresh Circuit 74 - 1 Switch Output 71 - 2 Switch Outputs Linear Output Mode (71 Series) Response Time Repeatability Thermal Error General Protection Current Consumption Vibration Resistance Shock Resistance Material Mass MPS-71: 0,1 to 3,0 sec. (Factory set at 0,1), MPS-74: 0,2 Fixed NPN (Sinking), PNP (Sourcing) Open Collector Transistor, 30 VDC, 125 mA Output Signals, NPN or PNP, LED Indicator Optional Output - Analog 1-5VDC, ± 0,2% Linear Accuracy, 0,5% F.S MPS-71 <2 ms, MPS-74 <5 ms ± 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP40 MPS-71 <45 mA, MPS-74 <75 mA 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Body: Polycarbonate MPS-71: .25 g, MPS-74: 28 g 211 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 MPS-71 Open Collector Wiring MPS-74 Open Collector Wiring Pin # Grommet Lead Only 1 2 3 4 Brown: Black: Blue: White: 24 VDC NPN / PNP Open Collector 0 VDC NPN / PNP Open Collector Sensor Male Pin Out 4 Brown: Black: Blue: White: Pink: Orange: 24 VDC NPN / PNP 0 VDC NPN / PNP NPN / PNP NPN / PNP Open Collector Open Collector Open Collector Open Collector 2 3 1 Internal Circuit (Brown) +V Main Circuit (Black) Out 1 (White) Out 2 (Pink) Out 3 (74E) (Orange) Out 4 (74E) (Blue) O V MPS-71 & MPS-74 NPN / PNP Open Collector ! Cautions The MPS-7 Central Display is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Installation • Avoid short-circuiting the MPS-7 Series. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using Panel Mount Bracket or Back Mount Brackets. Error Messages Display Operations • Dedicate a power supply of 10,8 to 30 VDC to the MPS-7 Se ries and set the ripple to Vp-p10% or less. Avoid excessive voltage. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. 212 Description Solutions Err Zero Reset Error Reset Zero PErr Peak Value Error Source Check Vacuum Contact Factory Er1 System Error (Internal) CE1 Over current of Output 1 CE2 Over current of Output 2 CE3 Over current of Output 3 (MPS-74) maximum 125 mA. CE4 Over current of Output 4 (MPS-74) FFF –FF Applied pressure exceeds pressure range Load current exceeds Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 Dimensions 30 MPS-71 2- M3 29 5 20 16,5 30 5 1 4 3 2 1 2 AMP EI 5-Pin Connector 171826-5 MPS-ACCK1 14 Mounting Bracket (Included) 14 7 5,5 25 27 20 C 28 Ø 4,5 Ø 4,5 20 20 20 30 43 13 6 5,5 22 35 13 MPS-74 40 25 AMP EI 5-Pin Connector 171825-5 10,5 CH-2 5 4 3 2 CH-1 1 5 1 5 CH-4 5 40 4 3 2 4 3 2 CH-2 1 5 1 5 CH-3 4 3 2 4 3 2 CH-1 1 5 1 5 CH-4 4 3 2 4 3 2 1 CH-3 4 3 2 1 1 2 3 4 Reset IN 5 2- M3 5 4 3 2 1 5 2- M3 30 30 30 MPS-ACCK3 Mounting Bracket Ø 3,5 30 Ø 4,5 (Included) Ø 4,5 7 5,5 6 25 30 Ø 3,5 5,5 20 26 20 37 38 22 213 14,6 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 See page 181 for Symbol Explanation 2 Press 1 Hold Press 2x 3 Output Set Open or Closed Easy Mode Activation 4 Press Press 4x Output Mode 1 Hysteresis or Window Comparator 1x 1x 5 Press Output Mode 2 Hysteresis or Window Comparator 3x Output 1 Switch Point Setting 6 Press 5x Output 2 Switch Point Setting Hysteresis Mode Automatic Teach Mode & Auto Surveillance Hysteresis Mode Vacuum Cycle Window Comparator Mode Low High 7 Press High 6x 8 Press 7x Display Refresh Settings / Output Response Time Interval 10 Press 9x Low Positive Pressure Pressure 9 Press 8x Display Peak Value Bottom Value or Their Difference 11 Hold Press Select Units of Measure Select Pressure Vacuum Release Cycle Window Comparator Mode Low 1x Lock Hold Press 12 Press Special Display Features 1x Press 1x 13 Press 3 Sec 1x Unlock Peak Value Bottom Value Zero Reset Compound Pressure 214 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors 1 Hold Press MPS-7 2 1x Press 1x Output Selection Normally Open / Normally Closed 1 2 3 4 1 2 3 4 Select Output Mode Hysteresis or Window Comparator Output Setting Peak Surveillance (Repeat Procedure for Each Channel) Window Hysteresis Comparator Mode Mode C 3 Press 4 2x Press 3x Select Remote Pressure Select Unit of Measure Save Energy Mode Digital IN Mode 1 2 3 4 1 2 3 4 Vacuum Low Pressure Standard Pressure Compound Pressure 5 Press and Hold 3 Seconds Scan Mode 1 2 3 4 6 Hold Press 1x 1 2 3 4 1 2 3 4 Lock Hold Press 1x 1 2 3 4 Unlock 3 Second Intervals 215 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 Accessories Cables (Applicable to MPS-71E Display Units Only) CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 216 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-7 Accessories MPS-ACCH4 Panel Mounting Bracket for MPS-71 43,8 40 40 Knockout 33,4 1 36 (+0.5, -0.2) 2 C 36 (+0.5, -0.2) MPS-ACCH5 Panel Mounting Bracket for MPS-74 53,8 50 50 Knockout 1 2 3 4 46 (+0,5, -0,2) 46 (+0,5, -0,2) 217 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-8 Features MPS-8 • Pressure Ranges: Vacuum ................................... 0 to -1 bar • Sensor Outputs: 1 NPN / PNP Open Collector Transistor Output 30 VDC, 125 mA 1 Analog Output 1 to 5 VDC • Switch Point 2/3 Trimmer Adjustment • Fixed Hysteresis 2% • 10 mm Wide • Compatible with MPS-7 Display • IP40 and CE Marked • Air and Non-Corrosive Gases Model Number Output MPS-V8A-PG PNP Pressure Range 0 to -1 bar MPS-V8U-AG Analog 0 to -1 bar MPS-V8U-AGE Analog 0 to -1 bar Output Mode Switch Output The MPS-8 Sensor is 10 mm wide with an NPN / PNP open collector switch output or an analog output. The MPS-8 can be used in combination with the MPS-7 series display or as a stand alone unit. Analog output is required for use with the MPS-7 display. 0 on S Fixed 2% off on off -1 bar Output (Volts) Analog Output 5 1 0 218 0 Pressure Max. Rating 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-8 Model Number Index MPS - V Pressure Range V 0 to -1 bar A B C U T 8 Port Size M5 Through Female M5 Through Female (With Mtg.) M5 Bottom Female M5 Bottom Swivel Male 4 mm Tube Stud A - A G Output Circuit A Analog (1-5VDC) N NPN Sinking Output P PNP Sourcing Output Connector / Cable G Grommet (2 m) GE 2 m Grommet Clip Conn.* * Use with MPS-7 Series Display, with Analog Only C Specifications Media Pressure Port Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Switch Output Linear Output Switch Point Setting Hysteresis Response Time Repeatability Thermal Error General Protection Current Consumption Spike Protection Dielectric Strength Insulation Resistance Vibration Resistance Shock Resistance Material Mass Air and Non-Corrosive Gases M5 Female, M5 Male Swivel, 4 mm Tube Stud V: 5 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH G: Grommet Open Lead; GE: Clip Type for use with MPS-7 Series 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 1 Output, Normally Open, NPN or PNP Open Collector Transistor, 30 VDC, 125 mA Analog Output 1 to 5 VDC 2/3 Trimmer < 2% of F.S. Fixed <1 ms < 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP40, EMC rating : EN55011 Class B, EN50082-2 < 20 mA Vp-p 400 v, 0,5 ms Surge Protection 1000 VAC, 1 min. > 100 Mohms at 500 VDC 10 to 55 Hz, 1,5 mm amplitude, XYZ, 2 hrs. 100 G, XYZ Body: Polycarbonate; Pressure Port: Anodized Aluminum 4g 219 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-8 Open Collector Wiring Analog Wiring Grommet Lead Only Brown: 24 VDC Blue: 0 VDC Black: NPN / PNP Open Collector Grommet Lead Only Brown: 24 VDC Blue: 0 VDC Black: Analog 1 to 5 VDC Internal Circuit (Brown) +V D1 (Black) Out 1 Tr1 ZD1 (Blue) OV LOAD Max. 125 mA Main Circuit Main Circuit D1 +DC - 10,8 V to 30 V Tr1 (Brown) +V ZD1 (Black) Out 1 (N.O.) LOAD Max. 125 mA (Blue) O V +DC - 10,8 V to 30 V PNP Open Collector NPN Open Collector Main Circuit (Brown) +V (Black) Analog 1 to 5 V Output +DC - 10,8 V to 30 V (Blue) O V Analog ! Cautions The MPS-8 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using the metal mounting base. Operations • Dedicate a power supply of 10.8 to 30VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. 220 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-8 Dimensions MPS-8A M5 Female, Grommet 16 M5-6 M5-6 10 MPS-8B M5 Female, Grommet 20 4,75 M5-6 21 M5-6 10 3 Ø 3,5 2-Places 10 20 MPS-8C M5 Female, Grommet 16 C 4,75 4 Ø 3,2 2-Places 14 10 20 4,75 M5-6 MPS-8U M5 Male Swivel, Grommet 10,5 20,9 4 Swivel Joint for Manifold Mount 4,75 20 M5 Connector (AMP) 170204-15 8 Housing (AMP) 171822-5 Shield Grommet Clip Connector (Available for All Models) 2m 221 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Features MVS-201 • Pressure Range: Compound Pressure ................. -1 to 5 bar • Time Controlled Sensor • Intelligent Simple 4-wire System • Eliminate I/O for Release Valve • 2 Functions with One Rung of Code • Automatic Timer (0-9,9 sec.) Function by Sensor Control Driver for Vacuum Generating and Release Valves • Peak Value Preventative Maintenance Confirmation • Response Time Less Than 2 Milliseconds • CE Rated The MVS-201 is a winning combination with the MC2, CVR-2, and CVK vacuum generators. The MVS-201 automatically provides an output signal for the blow-off function without the need of an additional output from the PLC. Begin the vacuum cycle with an input signal from the PLC to the “201” sensor. The “201” sensor has one output NPN or PNP for vacuum confirmation and a control output that interfaces directly with the blow-off release pilot valve. With programmable time control features and a special chip driver, the sensor automatically activates the blow-off release when the vacuum signal from the PLC is discontinued. This eliminates, THE PREVIOUSLY REQUIRED, PLC output to activate the blow-off release This new technology eliminates PLC output requirements by 50% and reduces installation to a simple 4 wire system by wiring the sensor only. There are 3 modes of operation for various applications. The output response time of the sensor is less than 2,5 msec. Peak limit prevention maintenance feature is automatically recorded internally. Basic PLC System P L C I N O U T -+ PLC System with 201 Sensor Vacuum Pilot Blow-Off Pilot P L C I N O U T Sensor Sensor Output 1 Sensor Output 2 -+ Vacuum Part Present Output (V) (V) (B) Output Modes Switch Output 0 The MVS-201 Series Sensor has one independent NPN or PNP open collector output signal. The Switch Output Mode has a switch point programmed by the user at a specific pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). on h off on off H -1 bar 222 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Model Number MVS - 201 - PCP Specifications Pressure Range Units of Measure Display Resolution Media Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Display Resolution & Units of Measure Display Frequency Circuit Digital Output Mode Response Time Repeatability Thermal Error General Protection Current Consumption Spike Protection Dielectric Strength Insulation Resistance Vibration Resistance Shock Resistance Material Mass Compound (R) kPa: 1 Non-Lubricated Air and Non-Corrosive Gases 6 bar 0 to 50 °C C -10 to 60 °C 35 to 85% RH C: 4-Pin, M8 Connector 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 3-Digit, 7-Segment LED kPa: 1, bar: 0,01, kgf/cm2: 0,01, PSI: 0,1 5 Hz NPN (Sinking), PNP (Sourcing) Open Collector Transistor Individually Selectable N.O. or N.C., max 125 mA, 30 V, with Overcurrent Protection OP1, OP2, OP3 Hysteresis: 0 to 100% of Switch Point < 2 ms ± 0,3% F.S. ± 0,2% F.S. in Temperature Range 0 to 50 °C IP40, CE Rating EMC-EN55011 Class B, EN50082-1 < 45 mA, < 25 mA When Utilizing Screen Saver Option 350 Vp, 1, µs 1000 VAC 1 min. > 100 Mohms at 500 VDC 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Body: Polycarbonate 48 g 223 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Wiring Diagram Sensor Male Pin Out M8 Pin # 1 2 3 4 201 1 2 3 4 Brown:24 VDC White: Input; PNP (24 VDC) Blue: 0 VDC Black: PNP Open Collector Output Pin # Red: Vacuum Solenoid Valve + V Black: Gnd Red: Break Solenoid Valve + V Black: Gnd 2 4 3 1 1 2 3 4 Internal Circuit (Brown) +V (DC 10.8 to 30V) (White) Suction/Break Command Input Digital IN Max. 125mA Load Main Circuit (Black) OUT 1 + - (Blue) OV 1 (Red) + - 2 (Black) 3 (Red) + - 4 (Black) Vacuum Solenoid Valve or TR Break Solenoid Valve Connector for connection of solenoid valve Connection is finished when Convum is installed PNP Sourcing ! Installation Cautions The MVS-201 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. Error Messages Display 224 Description Solutions Err Zero Reset Error 3% of F.S. Reset Zero Below Contact Factory Er1 System Error (Internal) CE1 Over current of Output 1 Load current exceeds FFF –FF Applied pressure exceeds pressure range Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Dimensions M8, 4-Pin 2 1 9 44 25 12,7 25 15 3 16 3,5 55,5 225 9 5 C 16 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Operating Modes Description of operation modes and terms on page 180. Mode: OP1 "Air Conservation / Timer Mode: OP2 "Vacuum Timer Option" ON (H-d) ON (H-d) PSI PSI OFF (h-d) OFF (h-d) inHg inHg OFF (h-v) ON (H-v) (P-v) Peak Limit OFF (h-v) ON (H-v) (P-v) Peak Limit Input ON Signal OFF Input ON Signal OFF Blow-Off ON Solenoid OFF Vacuum ON Solenoid OFF BT T2 T1 T1 Output 1 ON N.O. OFF Blow-Off ON Solenoid OFF Vacuum ON Solenoid OFF BT T2 T1 Output 1 ON N.O. OFF T1: Optional Vacuum Timer T2: Optional Blow-Off Delay Timer BT: Blow-Off Timer T1: Optional Vacuum Timer T2: Optional Blow-Off Delay Timer BT: Blow-Off Timer Timer Mode OP1 Timer Mode OP2 “Air Conservation / Vacuum Valve Timer” “Vacuum Valve Timer” This Vacuum valve control with the use of timing features conserves air consumption via the vacuum generator nonreturn check valve and sensor hysteresis function. Vacuum time (t1) can be used to control the vacuum valve for a specific length of time (0,0-9,9 sec.) after output 1 vacuum level is reached. The vacuum timing function (t1) will remove the signal from the sensor to the vacuum valve allowing the generator check valve system to conserve air consumption and vacuum. The vacuum valve will re-open for the same length of time (t1) when the pressure level drops to the hysteresis setting (h-v) (h-v). The operation will continue until the input signal is stopped. Optional delay timer between vacuum / blow-off (t2) and blow-off (bt) timer is available. After selecting OP1 OP1, set bt bt, t1 t1, and t2 values by using arrow “UP” and “DOWN” keys. To bypass any of these timing function operations, simply enter 0,00 seconds and the sensor will automatically proceed to the next function. This mode is ideal for use with CONVUM generators without check valves. Vacuum timer (t1) can be used to control the vacuum for a specific length of time (0,00 – 9,9 sec.) after output 1 is reached. Optional delay timer between vacuum / blow-off (t2) and blow-off (bt) timer is available. After selectt1, and t2 values by using arrow “UP” and ing OP2 OP2, set bt bt, t1 “DOWN” keys. To bypass any of these timing function operations, simply enter 0,00 seconds and the sensor will automatically proceed to the next function. 226 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Operating Modes Additional Sensor Features Description of operation modes and terms on page 180. (Available in All Operating Modes) Screen Saver Function (SaV) appears on display. This reduces current consumption by 20 mA and will activate after 10 seconds. Mode: OP3 "Signal Controlled Vacuum" Peak Value Level H-V / H-d: Switchpoints h-v / h-d: Switchpoints P-V: Peak Value ON (H-d) (p-u) appears on display. The sensor records this value for preventative maintenace issues. If this value is not reached the sensor will display an error message (ALP) indicating leaks or wear in the system. OFF (h-d) Vacuum Level Response Time PSI (ut ut) appears on the display. The sensor records the time ut (sec) to reach Output 1 and will display an error message (ALV) indicating Output 1 has not been reached within the acceptable time (sec) set by the user. inHg OFF (h-v) ON (H-v) (P-v) Peak Limit Input ON Signal OFF Blow-Off ON Solenoid OFF T2 Blow-off Time (dt) appears on the display. The sensor records the time (sec) to complete blow-off cycle and will display an error message (ALD) indicating (dt) has not reacting within the acceptable time (sec) set by the user. BT Vacuum ON Solenoid OFF Output 1 ON N.O. OFF T2: Optional Blow-Off Delay Timer BT: Blow-Off Timer Timer Mode OP3 “Signal Controlled Vacuum” The vacuum timer option (t1) is omitted and the PLC controls the input signal time for the vacuum operation. The delay timer between vacuum / blow-off (t2) and the blow-off (bt) timers are still available. After selecting OP3 OP3, set bt and t2 values by using arrow “UP” and “DOWN” keys. To bypass any of these timing function operations, simply enter 0,00 seconds and the sensor will automatically proceed to the next function. 227 04.10 www.parker.com/euro_pneumatic C Vacuum & Pressure Sensors 1 Press MVS-201 1x 2 1 Operating Mode 1 2 1 Switch Output 2 Operating Mode 2 Operating Mode 3 3 4 2 1 Outmode Open or Closed 2 1 Programming Symbols Legend Operation 1: Air Conservation / Timer Error Message - Blow-off Time Operation 2: Vacuum Timer Option Output 1 Operation 3: Signal Controlled Vacuum Vacuum Valve (Leave NO) Blow-Off Timer Blow-off Release Valve (Leave NO) Controlled Vacuum Signal with Timer Screen Saver Function Blow-Off Activation Timer Peak Vacuum Level Recorder Switch Output Value Vacuum Response Time Recorder Switch Output Hysteresis Value Blow-Off Time Recorder Blow-off Output Value Normally Open Blow-off Output Hysteresis Value Normally Closed Error Message - Peak Vacuum Level Low or High Signal to Vacuum Valve Error Message - Vacuum Response Time 228 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MVS-201 Accessories M8 Cables for Sensor CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 C CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 MVS-201 (Connects Sensor to Vacuum & Blowoff Release Pilot Valves) For CVK CVK-D201G For MC2 MC2-C201G 229 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Features MPS-3 Stainless • Fluids Non-Corrosive to Stainless Steel SUS 316L or SUS 630 Air Ammonia Brake Fluids Helium Hydraulic Fluids Freons Lubricating Oils Nitrogen Water • Pressure Ranges: Vacuum .................................. 0 to -1 bar Positive Pressure ................. 0 to 10 bar • Sensor Outputs: 2 NPN or PNP Open Collector Transistor Outputs, 30 VDC, 125 mA • Switch Point and High-low Programming Model Number Output Pressure Range MPS-V3F5-PC 2 PNP 0 to -1 bar MPS-P3S5-PC 2 PNP 0 to 10 bar • 4 Selectable Units of Measure (mmHg, -bar, -kPa, inHg) (kgf/cm2, PSI, bar, kPa) • Output Response Time Less Than 2,0 Milliseconds • IP65 Rated and CE Marked • Error Message Output Modes The MPS-3 Stainless Steel Series Sensor has two independent NPN or PNP open collector output signals. An analog output is optional. The Switch Output Mode has a switch point programmed by the user at a specific pressure. The Hysteresis Range (h) adjustment controls the output signal 0 to 100% below the Switch Point (H). The Window Comparator Mode provides two Switchpoint Settings (A) and (b) that control the output signals (NPN / PNP) between two pressures. This is referred to as the “High / Low” setting. Switch Output 0 on h off on off H -1 bar Window Comparator Output 0 off A on on b The optional Analog Output Signal is calibrated to the pressure scale of the sensor. off off -1 bar 230 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Model Number Index MPS - V3F Pressure Range V3F 0 to -1 bar P3S 0 to 10 bar 5 5 - P Port Size M5F 316SS C Circuit N NPN Sinking Output P PNP Sourcing Output Electrical Connector C 4-Pin, M8 G Grommet (2 m) C MPS-P3S5-PC MPS-P3S5-PG Specifications Pressure Range Vacuum (V3F) Units of Measure Display Resolution Media Pressure Port Proof Pressure Operating Temperature Storage Temperature Humidity Electrical Connection Power Supply Display Display Refresh Output Circuit Switch Outputs Output Modes Output Response Time Repeatability Thermal Error General Protection Current Consumption Vibration Resistance Shock Resistance Material Mass kPa: Positive (P35) 0,1 MPa: 0,001 Fluids, Non-Corrosive to 316L or 630 SUS S: MSF 31655 V3F: 10 bar, P3S: 20 bar 0 to 50 °C -10 to 60 °C 35 to 85% RH C: 4-Pin, M8 Connector, G: Grommet Open Lead 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection 3-Digit, 7-Segment LED 0,1 to 3,0 sec. (Factory set at 0,1) NPN (Sinking), PNP (Sourcing) Open Collector Transistor; 30 VDC, 125 mA 2 Output Signals, NPN or PNP, Normally Open or Closed, LED Indicator Hysteresis or Window Comparator < 2 ms with Programmable Increment 32, 128, 1024 ms ± 0,2% F.S. 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) IP 65 or IP 40, CE Rating, EMC-EN55011 Class B, EN 50082-2 < 55 mA 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. 10 G, XYZ Housing: Polycarbonate, Wetted Parts: P: 316L or V,R: 630 SUS (Diaphragm) 125 g 231 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Open Collector Wiring Pin # 1 Brown:24 VDC 2 White: NPN / PNP Open Collector Output 3 Blue: 0 VDC 4 Black: NPN / PNP Open Collector Output Sensor Male Pin Out 4 3 2 1 Internal Circuit for Open Collector and Analog Output Wiring Main Circuit Tr1 ZD1 Tr2 (Brown) +V Max. 125mA (Black) Out 1 Load Load (White) Out 2 Max. 125mA ZD2 D1 ZD2 Tr1 + DC – 10.8V 30V Main Circuit D1 1K ZD3 (Brown) +V ZD1 (Black) Out 1 Tr2 1K Max. Load (Blue) OV 125mA NPN The MPS-3 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. Operating Environment • Parker / Convum Sensors have not been investigated for ex plosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive volt age. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating tempera tures, and maximum pressure ranges of the system before installing. • Installation of air dryer system is recommended to remove moisture. DC – 10.8V 30V Load Max. 125mA ZD3 (Blue) OV ! Cautions + (White) Out 2 PNP • Depending on the system fluid and design, it may be nec essary to protect the diaphragm against pressure spikes by installing a flow restriction upstream from the sensor. Installation • Never insert an object into the pressure port other than an appropriate fluid connector. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using the metal mounting base. • To achieve IP65 rating, connect the o-ring and barb to a normal environment with a 2 mm I. D. tube. Error Messages Display 232 Description Solutions Err Zero Reset Error 3% of F.S. Reset Zero Below Er1 System Error (Internal) Contact Factory Restart Function Er2 Auto Teach Mode Error CE1 Over current of Output 1 Load current exceeds CE2 Over current of Output 2 maximum 125 mA. FFF –FF Applied pressure exceeds pressure range Apply pressures with the rating of the sensor 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Dimensions 5 M5 Female 5 M5 Female Grommet or M8, 4-Pin 30 M3 4 Places 20 30 20 12,2 4 6,7 M5 M8 C 4-Pin Connector M3 Venting Port MPS-ACCK1 Mounting Brackets 14 (Included) 14 7 5,5 25 27 28 20 20 20 20 30 43 Ø 4,5 Ø 4,5 13 6 35 5,5 22 233 13 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 See page 181 for Symbol Explanation 1 Hold Press 2 1x Press 2x Output Set Open or Closed Selecting Units of Measure Easy Mode Activation 4 Press 1x 3 Press 4x Output Mode 1 Hysteresis or Window Comparator 5 Press Output Mode 2 Hysteresis or Window Comparator 3x 6 Output 1 Switch Point Setting Output 2 Switch Point Setting Hysteresis Mode Hysteresis Mode Press 5x Automatic Teach Mode & Auto Surveillance Vacuum Cycle Window Comparator Mode Low High 7 Press High 6x 8 Press 7x Display Refresh Settings / Output Response Time Interval 10 Hold Press Release Cycle Window Comparator Mode Low 1x Lock Hold Press 9 Press Display Peak Value Bottom Value or Their Difference 1x Unlock 11 Press 1x Press 1x 8x Special Display Features 12 Press for 3 Seconds Zero Reset Bottom Value Peak Value 234 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-3 Accessories Cables CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m C 32 CB-M8-4P-5M-90 Ø 9,7 19 10,7 Ø5 5m 22 MPS-ACCH1 Panel Mounting Bracket 43,8 40 40 Knockout 33,4 1 36 (+0,5, -0,2) 2 36 (+0,5, -0,2) 235 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-5 Features MPS-5 Stainless • Pressure Ranges: Vacuum .................................. 0 to -1 bar Positive Pressure .................. 0 to 10 bar • Sensor Output: 1 to 5 VDC Output (Volts) Analog Output 5 1 0 0 Pressure Max. Rating • 316L SUS Diaphragm (Positive) • 630 SUS Diaphragm (Vacuum) Model Number Output MPS-V5FG-AG Analog Pressure Range 0 to -1 bar MPS-V5FG-AGE Analog 0 to -1 bar MPS-P5G-AG Analog 0 to 10 bar MPS-P5G-AGE Analog 0 to 10 bar • Compatible with MPS-7 Display for Remote Sensing • IP65 Rated and CE Marked The MPS-5 Series Transducer is constructed of 316L or 630 SUS with Analog output capabilities. The sensor can be used as a standalone unit or in combination with the MPS-7 Sensor Display. The analog output is 1 to 5 VDC (± 0,04) with accuracy linear 0,5% F.S. 236 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-5 Model Number Index MPS - V5F Pressure Range V5F 0 to -1 bar P5 0 to 10 bar Port Size G 1/4" BSPP Male, M5F G - A G Output Circuit A Analog 1 to 5 VDC Electrical Connector G Grommet (2 m) GE 2 m Grommet Clip Conn.* *Use with MPS-7 Series Display C MPS-V5FG-AG MPS-V5FG-AGE Specifications Media Liquids and Gases Non-Corrosive to 316SS Pressure Port G: 1/4" Male BSPP with M5 Female Proof Pressure V: 10 bar, P: 20 bar Operating Temperature 0 to 50 °C Storage Temperature -10 to 60 °C Humidity 35 to 85% RH Electrical Connection G: Grommet Open Lead, GE: Clip Type for use with MPS-7 Power Supply 10,8 to 30 VDC, Ripple Vp-p 10% Max., Reverse Voltage Protection Linear Output Analog Output 1 to 5 VDC Thermal Error 1% over ±25 °C (77 °C) Temperature Change (Range 0 to 50 °C) General Protection IP65 or IP40, EMC Rating : EN55011 Class B, EN50082-2 Current Consumption < 20 mA Spike Protection 400 VP, 1 µs Dielectric Strength 1000 VAC, 1min. Insulation Resistance > 100 Mohms at 500 VDC Vibration Resistance 10 to 55 Hz, 1,5 mm, XYZ, 2 hrs. Shock Resistance 10 G, XYZ Material Housing: 303 SUS, Wetted Parts: P: 316L SUS, V: 630 SUS (Diaphragm) Mass 110 g 237 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors Analog Wiring Sensor Male Pin Out Pin # 1 2 3 4 MPS-5 Brown: 24 VDC Black: Analog 1-5 VDC Blue: 0 VDC Not Used 4 3 2 1 Internal Circuit Main Circuit (Brown) +V (Black) Analog 1 to 5V Output +DC - 10.8V to 30V (Blue) OV Analog ! Cautions The MPS-5 Pressure Sensor is designed to monitor pressure and is not a safety measure to prevent accidents. The compatibility of the sensor is the responsibility of the designer of the system and specifications. • Depending on the system fluid and design, it may be necessary to protect the diaphragm against pressure spikes by installing a flow restriction upstream from the sensor. Installation • Never insert an object into the pressure port other than an appropriate fluid connector. Operating Environment • Parker / Convum Sensors have not been investigated for explosion-proof construction in hazardous environments. • Do not use with flammable gases, liquids, or in hazardous environments. • Avoid installing the sensor in locations where excessive voltage surges could damage or affect the performance of the sensor. • Avoid short-circuiting the sensor. Connect the brown lead to V+ and blue lead to 0 V. • Do not connect the output lead wires (black / white) to the power supply. • Outputs not being used should be trimmed and insulated. • Install using the metal mounting base. • To achieve IP65 rating, connect the o-ring and barb to a normal environment with a 2 mm I. D. tube. Operations • Dedicate a power supply of 10,8 to 30 VDC to the sensor and set the ripple to Vp-p10% or less. Avoid excessive voltage. Avoid voltage surges. • A small amount of internal voltage drop is possible. Ensure the power supply minus any internal voltage drop exceeds the operating load. • Verify the operating media is compatible with the specified sensor. Check the chemical make-up, operating temperatures, and maximum pressure ranges of the system before installing. 238 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors MPS-5 Dimensions G 1/4" Male Grommet 27 15 Ø 27 40,5 M5 x 1,0 2m 5,2 1/4" BSPP C G 1/4" Male Grommet Clip Connector 27 15 40,5 Connector (AMP) 170204-15 Ø 27 Housing (AMP) 171822-5 Shield M5 x 1,0 5,2 2m 1/4" BSPP 239 04.10 www.parker.com/euro_pneumatic Vacuum Sensor P5V-SV The P5V-SV is an improved adjustable vacuum switch of membrane type, having changeover contact function. Cables are connected using a DIN 43650A cable set. The switch is capable of withstanding positive pressures up to 35 bar. It is easy to adjust, has low weight and it is attractively designed. As delivered, the switch is preset for 75% vacuum. Specification Material Body Cap Black anodised aluminium Thermoplastic Technical data Working pressure Working temperature [°C] Maximum over pressure 15% to 90% vacuum (-0,15 to -0,9 bar) -40 to +80 Up to 35 bar Options and additional information Repeatability Hysteresis ±2% 20% of the preset value (0,15 bar at 75% vacuum) IP 65 250 VAC/24 VDC 5 A inductive 7 A resistive Enclosure Contact loading Preset value: 75% vacuum Main data for Vacuum Switch Symbol Connection (vacuum) Male G1/8 240 Weight kg 0,090 Order code P5V-SVVA16K 04.10 www.parker.com/euro_pneumatic Vacuum Sensor P5V-SV Vacuum Switch, P5V-SVVA16K 50 108 Electrical diagram 13,5 20,3 NV 29 10 C G1/8 19,3 31,6 241 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors – Accessories CB Features • M8, Female • Length: 2 m or 5 m • Cover: PVC or PUR • Connection Type: Swivel Straight or Angled • IP 67 Swivel Connector Common Part Numbers Item CB-M8-4P-2M CB-M8-4P-5M CB-M8-4P-5M-90 Connector M8 Female M8 Female M8 Angled Female Contacts 4 4 4 Length 2m 5m 5m Cover PVC PUR PUR CB-M8-4P-2M Ø 9,7 Ø5 2m 32 CB-M8-4P-5M Ø 9,7 Ø5 5m 32 CB-M8-4P-5M-90 Ø 9,7 Ø 9,7 19 10,7 Ø5 5m 22 242 04.10 www.parker.com/euro_pneumatic Vacuum & Pressure Sensors – Accessories MPS-ACCH Panel Knockout Dimensions Description For Use With MPS-3S MPS-ACCH1 MPS-4 MPS-3 MPS-ACCH7 MPS-31 MPS-ACCH4 MPS-71 MPS-ACCH5 MPS-74 C MPS-ACCH1, MPS-ACCH7, MPS-ACCH4 43,8 40 40 Knockout 33,4 1 36 (+0,5, -0,2) 2 36 (+0,5, -0,2) MPS-ACCH5 53,8 50 50 Knockout 1 2 3 4 46 (+0,5, -0,2) 46 (+0,5, -0,2) 243 04.10 www.parker.com/euro_pneumatic