TSX-8500

Transcription

TSX-8500
TSX-8500
Insulation for Exposed Use
PRODUCT DESCRIPTION
Compliances
Rmax TSX-8500 is an energy-efficient thermal insulation board
composed of a closed-cell polyisocyanurate (Polyiso) foam core
bonded to embossed, glass fiber reinforced aluminum foil facers
on both sides. The exposed side of the board has a heavy 12mil
facer with an aluminum reflective surface. The other side is
marked in production to ensure proper installation. TSX-8500
utilizes a CFC-, HCFC- and HFC-free blowing agent that has
zero Ozone Depletion Potential (ODP) and negligible Global
Warming Potential (GWP). This pressure washable insulation
is suitable for use in walls or ceilings and some limited roofing
applications in commercial, agricultural and industrial buildings
– new construction or thermal retrofit. Specifically, TSX-8500 is
ideal for masonry or stud construction; farm or storage buildings;
pre-engineered metal buildings; laminate panels and other
similar applications. TSX-8500 is designed to be left exposed
without a thermal barrier to provide an attractive interior finish.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
ASTM C1289 Type I, Class 1
ASHRAE 90.1
International Energy Conservation Code (IECC)
International Building Code (IBC) Section 2603, Foam Plastic
DrJ TER 1309-03
ESR-1864, ICC Evaluation Service
Miami-Dade County Product Control Approved
RR 25322, City of Los Angeles Research Report
California Code of Regulations, Title 24
Class A Flame Spread and Smoke Developed Indices per
IBC Chapter 8, Interior Finishes
Tested per UL1715 to comply with IBC Section 2603,
Special Approval paragraph
• Up to 4.5 inches on walls
• Up to 12 inches on ceilings
Tested per NFPA 285 to comply with IBC Section 2603.5.5
Water-Resistive Barrier (WRB) per AC71
(ASTM E331, AATCC Test Method 127)
Air Barrier Material per ASTM E2178
THERMAL PROPERTIES / PRODUCT DATA
“R” means resistance to heat flow. The higher the R-value, the greater
the insulating power.
PRODUCT BENEFITS
•
•
•
•
•
•
•
•
•
•
•
Part of the overall design solution
Installed continuously to reduce thermal bridging
Meets R-value requirements with a thinner profile
Blocks air and moisture
Mold resistant per ASTM D3273 (no defacement)
Reduces energy costs
Reflective facer acts as a radiant barrier
Pressure Washable
Lightweight and easy to install
Reduces material and labor costs
Tested per NFPA 285 without requiring exterior gypsum
board or fire-stops around header openings
• Contributes toward LEED credits in the following categories:
• Energy & Atmosphere
• Materials & Resources
• Offers tax credit, where applicable
2015-01
Nominal
Thickness
Thermal R-Value1
System R-Value2
Inches
°F•ft2•hr/Btu
°F•ft2•hr/Btu
Pcs/Bdl
0.75
5.0
7.77
60
1.00
6.0
8.77
48
1.50
9.6
12.37
32
1.55
10.0
12.77
30
2.00
13.1
15.87
24
2.50
16.7
19.47
19
3.00
20.3
23.07
16
3.50
23.9
26.67
13
4.00
27.4
30.17
12
4.50
31.0
33.77
10
Thermal values are determined by using ASTM C518 test method at 75°F mean temperature on
material conditioned according to PIMA Technical Bulletin No. 101. 2
Includes the ASHRAE assigned 2.77 R-value of a ¾ inch air tight space against a reflective foil in
a typical wall assembly.
1
Additional thermal R-values can be found on the insert to this document. TSX-8500 is
shipped in bundles that are approximately 48 inches high and wrapped in plastic for easy
handling. Visit www.rmax.com for a complete list of thicknesses and packaging information.
TSX-8500
TYPICAL PHYSICAL PROPERTIES
Physical properties shown are based on data obtained under controlled
conditions and are subject to normal manufacturing tolerances.
Property
Test Method
Results
Density, Overall, Nominal
ASTM D1622
2.0 pcf
Compressive Strength1
ASTM D1621
20 psi Standard
Also Available in 25 psi
Upon Request
Flame Spread, Faced2
ASTM E84
25 or Less
Smoke Developed, Faced2
ASTM E84
< 450
Water Vapor Transmission
ASTM E96
< 0.03 Perm
Water Absorption
ASTM C209
< 0.2% Vol.
Dimensional Stability
ASTM D2126,
< 2% Linear Change
Reflectance
Emittance
ASTM E408
0.96
0.04
Air Permeance
ASTM E2178
< 0.02 L/(s.m2)
7 days, 158°F, 98% rh
Service Temperatures
-40°F to +250°F
Water-Resistive Barrier - When TSX-8500 is installed over wood
or steel studs with the joints sealed, it serves as a Water-Resistive
Barrier. TSX-8500 has been tested per the guidelines set forth in the
ICC-ES Acceptance Criteria for Foam Plastic Sheathing Panels Used
as Water-Resistive Barriers (AC71). For use as a WRB, TSX-8500
shall be installed with board joints placed directly over wood or steel
framing spaced a maximum of 24 inches o.c. All insulation board joints
shall be covered by R-SEAL 3000 tape. All transitions and throughwall
penetrations must be flashed to comply with applicable code.
Exterior Walls - TSX-8500 can be specified in exterior walls of
buildings of any height utilizing brick veneer, stucco, limestone or natural
stone veneer, cast artificial stone veneer, MCM, ACM, terracotta cladding,
metal skin, cement board siding, stone/aluminum honeycomb composite
panels, AAC panels or thin brick. TSX-8500 has been tested per
NFPA 285 and successfully passes with the exposed side facing the
exterior. The NFPA 285 listing/approval is dependent on all components
of the assembly. For a full explanation of approved assemblies and
acceptable components, refer to Rmax Architectural Solutions: NFPA 285
and Exterior Walls with Rmax TSX-8500. Third party evaluations and
listings should also be consulted for specific instructions.
Less than 1” is only available at 16psi.
2
Flame spread and smoke numbers are shown for comparison purposes only and are
not intended to represent the performance of TSX-8500 and related components under
actual fire conditions.
1
APPLICATION / INSTALLATION
General - TSX-8500 passes UL1715 (walls only or ceilings
only) in single or multiple layers without joint treatment of any
kind. Therefore, the boards only need to be tightly butted.
However, taping the seams is acceptable using R-SEAL 3000,
or equivalent. For a more professional, finished look, use Rmax’s
PVC insulation clip. Refer to Rmax publication, Joint Closure
Recommendations and Installation Instructions for Interior Exposed
Applications, for additional information and guidelines on installation,
joint treatment and sealing techniques. TSX-8500 may be covered with
an interior finish product provided it is compliant with the requirements of
IBC Chapter 8, including interior paint. A quality grade acrylic latex paint
is recommended for coating the surface. While primer is not generally
required, consult the paint manufacturer and/or industrial paint supply for
recommendations and best practice.
Securement – TSX-8500 may be fastened to wood framing using
roofing nails, bugle head screws or minimum 3/4 inch cap nails. The
fasteners shall be long enough to penetrate wood framing a minimum
of 1 inch. TSX-8500 may be fastened to metal framing using self-taping
screws and plastic washers. The fasteners shall be long enough to
penetrate metal framing a minimum of four threads. Wherever possible,
the insulation boards shall be installed vertically with all edges tightly
butted and backing by framing. When the insulation boards are installed
horizontally, i.e., perpendicular to framing, the maximum span shall be
5 feet. TSX-8500 may be secured to concrete surfaces using plastic
masonry fasteners with washer or a quality grade construction adhesive.
Pre-Engineered Metal Buildings - TSX-8500 provides a layer of
continuous insulation (ci) for walls or ceilings of pre-engineered metal
buildings in one easy step. The TSX-8500 is simply fastened to the face
of the girts or between the girts and the metal exterior skin of the building.
Use Rmax PVC clips for an easy yet clean, professional installation.
Agricultural, Farm, Storage Buildings and Other Light
Commercial Structures - TSX-8500 may be used as an exposed,
finished, continuous insulation (ci) system in agricultural, farm, storage
buildings and other light commercial structures. It may be secured directly
to the wood or metal framing members, or use Rmax PVC insulation
clips for an easy yet clean, professional installation.
LIMITATIONS
TSX-8500 is not recommended, nor warranted, for use as a commercial
roof insulation directly under membrane systems. Consult Rmax Sales
for suitable commercial roof insulation products.
TSX-8500 is not a structural panel. It must not be used as a nailing
base for any other building products. Furthermore, walls insulated with
TSX-8500 must be properly braced for lateral loads according to the
requirements of local Building Codes.
WARNING
Polyiso foam is an organic material which will burn when exposed to
an ignition source of sufficient heat and intensity and may contribute to
flames spreading.
Consult local Building Codes and insurance authorities regarding special
applications or details required when using TSX-8500 as an exposed
product.
Per the IBC and IRC, a WRB is required behind the exterior wall veneer.
Masonry - TSX-8500 is applied to the interior face of concrete or
concrete masonry to provide a layer of continuous insulation (ci) over the
entire surface. It may be adhered or anchored directly to the concrete
surface or attached to furring. Use Rmax PVC clips for an easy yet clean,
professional installation. For example, TSX-8500 is an excellent product
for use in insulating block walls, standard cavity walls and the underside
of slabs such as ceilings of parking structures. It can also be used in
conjunction with tilt-up wall panels.
Pressure Washable - TSX-8500 is pressure washable, up to 1000
psi using a cleaning spray rig. The wand nozzle must have a fan spray
tip with an angle of at least 15 degrees. The washing wand should not be
used at a distance of less than 3 feet from the surface of the insulation
board. Pressures greater than 1000 psi may result in damage to the
insulation facer.
The code also has provisions regarding vapor retarders, type and
location, based on the assembly, climate zone and the amount of
continuous insulation. It is up to the design professional to specify an
assembly that will perform adequately and meet these requirements.
WARRANTY
See Rmax “Sales Policy” and applicable warranties for terms and
conditions. Rmax does not assume any responsibility or liability for the
performance of any products other than those manufactured by Rmax.
NOTE: All Rmax products must be tarped, placed on skids and kept
dry before and throughout construction.
TSX-8500
TSX-8500
Additional THERMAL R-Values
Doing one thing well
in so many ways...
Rmax is a U.S. owned
company that only
manufactures Polyiso
insulation. TSX-8500 is
manufactured in the U.S.
and is offered through
an extensive distribution
network. It is available in
standard four foot wide
panels, with standard panel
lengths of eight or nine feet.
Custom lengths are available
for special orders. Contact
Rmax Sales at your regional
Customer Service Center
for product availability,
pricing information, and your
nearest distribution center.
Corporate & Technical
Rmax Operating, LLC
13524 Welch Road
Dallas, Texas 75244-5291
Phone: (972) 387-4500
Fax: (972) 387-4673
Email: [email protected]
Web: www.rmax.com
Customer Service &
Plant Locations
Central Region
Dallas, Texas
(800) 527-0890 Ext. 102
Eastern Region
Greer, South Carolina
(800) 845-4455 Ext. 156
Western Region
Fernley, Nevada
(800) 762-9462 Ext. 156
2015-01
“R” means resistance to heat flow. The higher the R-value,
the greater the insulating power. According to the ASHRAE
Handbook of Fundamentals, the reflective foil facing of
TSX-8500 contributes additional R-value to the overall
assembly when installed against an air tight space. For
example, ASHRAE assigns a 2.77 R-value to a 3/4 inch
dead-air space against a reflective foil in a typical wall
assembly. This value is in addition to the R-value of the
Polyiso foam - see System R-Value below.
Nominal
Thickness
Thermal
R-Value1
System
R-Value
Inches
°F•ft2•hr/Btu
°F•ft2•hr/Btu
0.75
5.0
7.77
60
1.00
6.0
8.77
48
1.25
7.8
10.57
38
1.50
9.6
12.37
32
1.55
10.0
12.77
30
Pcs/Bdl
1.75
11.4
14.17
27
2.00
13.1
15.87
24
2.25
14.9
17.67
21
2.30
15.3
18.07
20
2.50
16.7
19.47
19
2.75
18.5
21.27
17
3.00
20.3
23.07
16
3.25
22.1
24.87
14
3.50
23.9
26.67
13
3.75
25.7
28.47
12
4.00
27.4
30.17
12
4.25
29.2
31.97
11
4.50
31.0
33.77
10
1
Thermal values are determined by using ASTM C518 test method at
75°F mean temperature on material conditioned according to PIMA
Technical Bulletin No. 101.
TSX-8500 is shipped in bundles that are approximately 48
inches high and wrapped in plastic for easy handling.
Visit www.rmax.com for a complete list of thicknesses and
packaging information.
Improving Your Design.
For warranties, limitations and conditions refer to Rmax Sales Policy and applicable warranties. All documents are
located at www.rmax.com. For technical and sales support, email [email protected] or call (800) 527-0890.
Proudly Made and Engineered in the U.S.A.
Rmax Sales Offices and Plant Locations
Central:
13524 Welch Road
Dallas, Texas 75244
East:
1649 South Batesville Road
Greer, South Carolina 29650
West:
210 Lyon Drive
Fernley, Nevada 89408
Phone: 972-387-4500
Fax: 972-387-4673
Toll Free: 1-800-527-0890
Phone: 864-297-1382
Fax: 864-234-7548
Toll Free: 1-800-845-4455
Phone: 775-575-4849
Fax: 775-575-5035
Toll Free: 1-800-762-9462
E-mail us at [email protected] or visit our website www.rmax.com